E36 Approved by PreTreatment Tech 3 31 2022BLD2022-0289 R E S U B
CITY OF EDMONDS Mar 31 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
Grease Removal Equipment Ap ica ion
REVIEWED
Business Name Molly Moo_ n's Homemade_Icecream Date Subm [CITY
ted: 4/l/2Q22BY
Address: 558 Main Street Edmonds WA Suite No.: OF EDMONDS
Business Owner: Molly Neitzgl Mailing Address: 1 122 E. INke St.111448 Seattle, WA 98122
Contact Person/Title: Kevin Neit7xI Phone: 08-353-1611
Days/Hours of Operation: Noon till I Q m 7 daya pgr week
Total Number of Meals Served Per Peak Hour (assume all seats filled): N/A
Number of Seats: Dining: Lounge/Bar: Banquet Rooms: _ Deck/Patio:
Building Occupancy Permit Capacity: 49 Health Dept. Permit Capacity 49
Inventory of Kitchen Equipment and Plumbing Fixtures for this Establishment:
burners, ovens, hoods, deep fat fryers, wok stations, soup kettles, sinks, pre -was
dishwashers, disposers, mop sinks, floor drains, etc.) _
I each 3 compartment sink 2 dipwell floor sinks
1 each mop/washout sink 2 hand wash sinks 1 ice cream machine floor sink
h
(Grills,
sinks,
What proportion, if any, of the dishware used is of the disposable type? 1 f10'%, compostable
How is waste oil/grease handled, stored, and recycled/disposed? =N/A
35+ GPM P-rease interceptor- in kitchen pumped out aboul every 60 days
Milk fat solids are only fat produced.
Estimate gallons of waste oil/grease produced per month: N/A
If recycled, by which company? Ever--recn Onsite — The Septic Group
How are vent hoods cleaned and where does the cleaning waste go? N/A
Contact the Pretreatment Technician at 425-771-0237 ext. 1357 to discuss the
type and size of equipment you must install, and then complete the appropriate
accompanying worksheet for either a Gravity Grease Interceptor or a
Hydromechanical Grease Interceptor.
Hydromechanical Grease Interceptor Sizing Worksheet
[Revised 1/7/20221
Facility Name: Molly Moon's Homemade Icecream
Address: 558 Main St. Edmonds WA
Suite No.:
• A Hydromechanical Grease Interceptor (HGI) plumbing permit is required ($165.00 fee).
Contact the Pretreatment Technician (425-771-0237 ext. 1357) if you have any questions
regarding this form.
• Dishwashers are not allowed to be connected to a HGI.
• Food disposers are not allowed in a facility served by a HGI and must be disabled or
removed. Solids must be screened out and placed in the solid waste container.
Fixture Capacity in Cubic
Inches
(L x W x D x no. of sinks)
Fixture Capacity
in Gallons
(Cu. In. - 231)
Drainage Load
(75% of Total
Capacity)
Flow Rate for
a 2-Minute
Drain Period
#1
45x15x14x1=9450c.i.
_ 231 = 40.9 gal. x .75 = 30.6 gal.
- 231 =14.9 gal. x .75 = 11.2gal.
_ 2 = 15.3 pm
#2
24x24x6x1=3456c.i.
- 2 = 5.6gpm
#3
1 Ox4x5x2=400c.i.
- 231 = 1.73ga1.
x .75 = 1.29gal.
- 2 = . gpm 1
#4
x x x = cd.
_ 231 = gal.
x .75 = gal.
_ 2 = gpm
HGI #1 — Total drainage flows from maximum of 4 fixtures
. gpm
#1
x x x = c.i.
- 231 = gal.
x .75 = gal.
- 2 = gpm
#2
x x x = c.i.
- 231 = gal.
x .75 = gal.
- 2 = gpm
#3
x x x = c.i.
_ 231 = gal.
x .75 = gal.
- 2 = gpm
#4
x x x - c.i.
-231 = gal.
x .75 = gal.
- 2 = gpm
HGI #2 — Total drainage flows from maximum of 4 fixtures
gpm
#1 Hydromechanical Grease Interceptor Size
#2 Hydromechanical Grease Interceptor Siz
(in gpm)
e
35
50
75
100 or greater
100 or greater
(in gpm)
35
50
75
If the calculated size is less than 35 gpm please circle the 35 gpm box.
The Minimum Hydromechanical Grease Interceptor size is 35 gpm as per City of Edmonds
Pretreatment Ordinance.
City may upsize for factors such as low temp/high volume dishwashing, if permitted, or
high oil/grease content on menu, etc.
Remarks:
Size Approved: �9 gpm
[Revised 1/712022]
(For City use only below this line)
Approved by:
Pretreatment Technician
4
Date: ')1311 ZL
,'(76