APPROVED RESUB 1-BLD2023-0796+Floor Plan+7.17.2023_3.04.17_PM+3669883FLOOR PLAN - LEVEL 01- STORAGE
ANALYSIS
1/4" = V-0"
GENERAL FLOOR PLAN NOTES
1. ALL DIMENSIONS TO EXISTING WALLS, WINDOWS, DOORS, AND OTHER BUILDING ELEMENTS ARE TO BE CONSIDERED APPROXIMATE,
AND ARE TO BE VERIFIED IN THE FIELD.
2. ALL WINDOWS AND DOORS THAT ARE EXISTING, TO BE REPLACED, ARE TO BE VERIFIED IN THE FIELD (MATCH HEIGHT, WIDTH,
LOCATION, AND POSITION). CONTRACTOR TO VERIFY ANY DESCREPANCIES WITH ARCHITECT PRIOR TO ORDERING.
3. ALL PLAN DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED
AS "CLEAR" (CLR) AND DIMENSIONS AT EXISTING FINISHED SURFACES TO REMAIN ARE TO FACES OF FINISHED MATERIALS.
4. NO ALTERATIONS TO GRADE, OR GROUND DISTURBANCE U.N.O.
5. ALL INTERIOR STUD WALLS TO BE NOMINAL 2x DIMENSION LUMBER @ 16" OC W/ 5/8" TYPE X GWB ON BOTH SIDES U.N.O.
6. WHERE EXPOSED DURING CONSTRUCTION, EXISTING CEILING OR WALL CAVITIES AT THE BOUNDARY BETWEEN CONDITIONED AND
UNCONDITIONED AREAS SHALL BE INSULATED TO FULL DEPTH WITH INSULATION HAVING A NOMINAL VALUE OF R-3.0 PER INCH PER
C503.1 ITEM 3.
PLAN LEGEND
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST i
ON JOB SITE
CITY OF EDMONDS
BUILDING DIVISION
APPROVED PLAN
07/19/2023
ff r i,& Ca4efeor
II Viale
OWNER
Brian Taylor & Louise Favier
610 5th Ave S
Suite B & C
Edmonds, WA 98020
ARCH ITECT
URBANAOO
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
2023.07.14
MECH PERMIT SUPPLEMENT
CONTRACTOR
DND DESIGN LLC
BLD2023-0796
RESUB
Jul 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
P ROJ ECT I N FO
PROJECT NUMBER: TBD
INTAKE DATE: 2023.03.10
PERMIT STAMP
ISSU E
# ADD. I REVISION DATE
SHEET
STORAGE LOADING ANALYSIS
A2.1a FOR REFERENCE: JULY 2023
STORAGE LOAD ANALYSIS BASED
ON APPROVED FRAMING PLANS
FROM PERMIT # BLD20040562
0' 2' 4' 8' 1 6'
A2.1a