Loading...
APPROVED PLN FIR ENG BLD BLD2023-0327+Architectural_Plan+3.10.2023_9.58.21_PM+3415527TYPICAL ABBREVIATIONS BUILDING & ZONING SUMMARY PROJECT CODE SUMMARY DRAWING INDEX II Viale & AND ETR EXISTING TO REMAIN MH MANHOLE SF SQUARE FOOT (FEET) @ AT EXC EXCAVATE/-ED/-ION MIN MINIMUM SH SHOWER # POUND/ NUMBER EXH EXHAUST HOOD MIR MIRROR SHD SHOWER HEAD ABV ABOVE EXP EXPANSION MISC MISCELLANEOUS SHT SHEET ACOUS ACOUSTICAL EXT EXTERIOR MO MASONRY OPENING SHTG SHEATHING ACT ACOUSTICAL CEILING TILE FA FIRE ALARM MONO MONOLITHIC SIM SIMILAR ADD ADDENDUM FB FIRE BLANKET MTL METAL SL SEALER ADDL ADDITIONAL FBR FACE BRICK MPC METAL PAN CEILING SLNT SEALANT ADJ ADJUSTABLE/ADJACENT FD FLOOR DRAIN MTD MOUNTED SLV SLEEVE ADMIN ADMINISTRATION FDN FOUNDATION MULL MULLION SM SURFACE MOUNTED AFF ABOVE FINISH FLOOR FDV FIRE DEPARTMENT VALVE (N) NEW SNC SANITARY NAPKIN CABINET AHU AIR HANDLING UNIT FE FIRE EXTINGUISHER MTL METAL SND SANITARY NAPKIN DISPOSEF ALT ALTERNATE FIGS FOAM GASKET SEAL MPC METAL PAN CEILING SOG SLAB ON GRADE ALUM ALUMINUM FH FIRE HOSE MTD MOUNTED SP STANDPIPE ANUN ANUNCIATOR FHC FIRE HOSE CABINET MULL MULLION SPC SPECIMEN PASS THROUGH AP ACCESS PANEL FHV FIRE HOSE VALVE (N) NEW CABINET APROX APPROXIMATE FIN FINISH NA NOT APPLICABLE SPEC SPECIFICATIONS ARCH ARCHITECTURAL/ ARCHITECT FIXT FIXTURE NIC NOT IN CONTRACT SPR SINGLE PLY ROOF BD BOARD FL FLOOR NO NUMBER SO. SQUARE BFE BOTTOM FOOTING ELEVATION FLASH FLASHING NOM NOMINAL SO. YD SQUARE YARD BG BUMPER GUARD FLEX FLEXIBLE NRC NOISE REDUCTION COEFFICIENT SR SIDEWALL REGISTER BLDG BUILDING FLG FLANGE NT NOTE SSTL STAINLESS STEEL BLKG BLOCKING FLUOR FLUORESCENT NTS NOT TO SCALE ST STREET BLW BELOW FOIC FURNISHED BY OWNER- OC ON CENTER ST STONE TILE BM BEAM INSTALLED BY CONTRACTOR OD OUTSIDE DIAMETER STC SOUND TRANSMISSION BO BOTTOM OF FP FIRE PROOFING OFCI OWNER FURNISHED - COEFFICIENT BOT BOTTOM FRMG FRAMING CONTRACTOR INSTALLED STD STANDARD BR BRICK FS FLOOR SINK OFF OFFICE STL STEEL BSMT BASEMENT FSTOP FIRESTOPPING OH OVERHEAD STN STONE BTWN BETWEEN FT FOOT/FEET OP OPERABLE PARTITION STOR STORAGE C CHANNEL FTG FOOTING OPNG OPENING STRUCT STRUCTURAL CAB CABINET FURR FURRING OPP OPPOSITE STS STEEL STRUCTURE i CANTL CANTILEVER FUT FUTURE ORD OVERFLOW ROOF DRAIN SW STEEL WINDOWS CAT CATEGORY GA GAUGE PART PARTITION SW SWITCH CCTV CLOSED CIRCUIT TELEVISION GAL GALLONS PC PRECAST CONCRETE SWD SOFTWOOD CD COILING DOOR GALV GALVANIZED PED PEDESTAL SYM SYMMETRICAL CG COILING GRILLE GB GRAB BAR PL PROPERTY LINE T TOP CG CORNER GUARD GB GRADE BEAM PLAM PLASTIC LAMINATE TAN TANGENT CH COAT HOOK GC GENERAL CONTRACTOR PLBG PLUMBING TBD TACKBOARD CJT CONTROLJOINT GENR GENERATOR PLS PLASTER TIC TIME CLOCK CL CENTER LINE GEN GENERAL PLW PLYWOOD TCAB TOWEL CABINET CLG CEILING GL GLASS PNL PANEL TDISP TISSUE DISPENSER CLR CLEAR GMU GLASS MASONRY UNIT PR PAIR TDR TRENCH DRAIN APPROVED BY PLANNING Apr 14 2023 LAND USE DATA: ZONE: BD3, WITHIN DOWNTOWN ALLIANCE BOUNDARY LEGAL DESCRIPTION: (SEC 26 TWP 27 RGE 03RT-4B) BEG 350 FT S & 30 FT W OF NE COR NE1/4 NE 1/4 TH W 120 FT TH S 112 FT TH E 120 FT TH N 112 FT TO TPB PRESENT USE: 581 Eating Places (PER SNOHOMISH COUNTY RECORDS) FLOOR AREA: SUITE B + C 1,668 SF PARKING: NO CHANGES PROPOSED. NO NEW PARKING REQUIRED PER EDMONDS CITY CODE 17.50.010.C.2. BUILDING DATA: CONSTRUCTION TYPE: VB (NOT SPRINKLERED) Nothing in the permit approval process shall be nterpreted as allowing or permitting the maintenance any currently existing illegal, nonconforming or unpermitted building, structure or site condition which s outside the scope of the permit application, regardless whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate CM CONSTRUCTION MANAGER GR GRADE PRELIM PRELIMINARY TEL TELEPHONE CO CASED OPENING GWB GYPSUM WALLBOARD PRESS PRESSURE TEMP TEMPERATURE enforcement action. COL COLUMN H HEIGHT/HIGH PRIM PRIMARY TER TERRAZZO CONC CONCRETE HB HOSE BIB PROJ PROJECTION T&G TONGUE & GROOVE CONF CONFERENCE HD HAND DRYER PRV POWER ROOF VENTILATOR THRES THRESHOLD CONN CONNECT/-ED/-ION HDR HEADER PNT PAINT TPH TOILET PAPER HOLDER CONST CONSTRUCTION HDW HARDWARE PTR PRINTER TR TREAD CONT CONTINUE/OUS HIM HOLLOW METAL PVC POLYVINYL CHLORIDE TRANSF TRANSFORMER CONTR CONTRACT/OR HORIZ HORIZONTAL R RADIUS TS TUBE SECTION COORD COORDINATE HPT HIGH POINT RA RETURN AIR TV TELEVISION CORR CORRIDOR HR HANDRAIL RB RESILIENT BASE TYP TYPICAL CPT CARPET HT HEIGHT RD ROOF DRAIN UC UNDERCUT CT CERAMIC TILE HTR HEATER RE RELOCATE EXISTING UFD UNDER FLOOR DUCT CTR CENTER HVAC HEATING, VENTILATING, AIR PR PAIR UG UNDERGROUND CTSK COUNTERSUNK CONDITIONING PRELIM PRELIMINARY UH UNIT HEATER CW CURTAIN WALL HW HOT WATER PRESS PRESSURE UNFIN UNFINISHED CYL CYLINDER IC INTERCOM PRIM PRIMARY UNO UNLESS NOTED OTHERWISE D DEPTH OR DEEP ID INSIDE DIAMETER PROJ PROJECTION UON UNLESS OTHERWISE NOTED DEMO DEMOLITION IN INCH PRV POWER ROOF VENTILATOR UTIL UTILITY DPR DEPRESSION INSUL INSULATION PNT PAINT UTIL UTILITY DEPT DEPARTMENT INT INTERIOR PTR PRINTER VC VALVE CABINET DF DRINKING FOUNTAIN ISO ISOLATION PVC POLYVINYL CHLORIDE VENT VENTILATION DIA DIAMETER JAN JANITOR R RADIUS VERT VERTICAL DIAG DIAGONAL JST JOIST RA RETURN AIR VEST VESTIBULE DIFF DIFFUSER JT JOINT RB RESILIENT BASE VIF VERIFY IN FIELD DIM DIMENSION KO KNOCK OUT RD ROOF DRAIN VTR VENT THROUGH ROOF DISP DISPENSER L ANGLE RE RELOCATE EXISTING W WIDTH/WIDE DIST DISTRIBUTION LAV LAVATORY REC RECESSED W WIDE FLANGE DIV DIVISION LB(S) POUND (S) REF REFERENCE W/ WITH DN DOWN LCD LINEAR CEILING DIFFUSER REFR REFRIGERATOR W/O WITHOUT DP DEMOUNTABLE PARTITION LIN LINEAR REG REGISTER WC WATER CLOSET DR DOOR LKR LOCKER REINF REINFORCE/-ED/-ING WC WALL COVERING DS DOWNSPOUT LOC LOCATION OR LOCATE REM REMOVE WD WOOD DWG DRAWING LPT LOW POINT READ REQUIRED WDW WINDOW (E) EXISTING LTG LIGHTING RET RETAINING WG WALL GUARD EA EACH LVR LOUVER REV REVERSE WH WALL HYDRANT EC ELECTRIC CABINET LWC LINEAR WOOD CEILING REV REVISE WHCH WHEELCHAIR EF EXHAUST FAN M MIDDLE RF RESILIENT FLOOR WHTR WATER HEATER EIFS EXTERIOR INSULATION AND MAN MANUAL RH ROOF HATCH WP WATERPROOF FINISH SYSTEM MATL MATERIAL RM ROOM WR WASTE RECEPTACLE EJT EXPANSION JOINT MAX MAXIMUM RO ROUGH OPENING WS WEATHERSTRIP EL ELEVATION MBD MARKER BOARD RS ROUGH SLAB WSCT WAINSCOT ELEC ELECTRICAL MC MEDICINE CABINET RWC RAIN WATER CONDUCTOR WT WINDOW TREATMENT ELEV ELEVATOR MCU MODULAR COOLING UNIT SCHED SCHEDULE WT WEIGHT EMERG EMERGENCY MECH MECHANICAL SD SHOWER DRAIN WWF WELDED WIRE FABRIC ENCL ENCLOSURE MEMB MEMBRANE SD SMOKE DAMPER ENTR ENTRANCE MEZZ MEZZANINE SDISP SOAP DISPENSER EQ EQUAL MFR MANUFACTURER EQUIP EQUIPMENT SYMBOL LEGEND N NORTH ARROW O CD REVISION CLOUD Room name 123 ROOM TAG 1 1 A101 1 EXTERIOR ELEVATION REFERENCE 1 1 1 A1.0 1 INTERIOR ELEVATION REFERENCE 1 SIM 1 EXISTING CONSTRUCTION A10.1 DATUM POINT DETAIL PLAN/SECTION CALLOUT EXISTING CONSTRUCTION 12'-011 SPOT ELEVATION TO BE DEMOLISHED 1i WALL / ASSEMBLY 50 SMOKE/CO NEW CONSTRUCTION REFERENCE. (� DETECTOR EXIT SIGN (DIRECTION ARROW) KEYNOTE REFERENCE O SIM BUILDING SECTION FIRE EXTINGUISHER CABINET 1 RE. 906.3 OF FIRE CODE) 41 REFERENCE A4.0 101a WINDOW TAG EF EXHAUST FAN µ 101 DOOR TAG $T LIGHT SWITCH 1t DUPLEX OUTLET ALIGN ALIGN WITH ESTABLISHED STRUCTURAL GRID + SURFACES (TGFI LIGHT SWITCH ELECTRICAL 10 CEILING HEIGHT - 0 r ri MATL. AND FINISH PANEL/METER Approved DFM chris gurt South County Fire Date: 04/14/2023 ALL WORK TO BE COMPLETED IN COMPLIANCE WITH THE FOLLOWING CODES AND REGULATIONS AS AMENDED OR MODIFIED BY THE GOVERNING BODY, APPROVING AND INSPECTING THE PROJECT: EDMONDS CITY CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL MECHANICAL CODE 2020 INTERNATIONAL ELECTRICAL CODE 2018 UNIFORM PLUMBING CODE 2018 WASHINGTON STATE ENERGY CODE 2018 INTERNATIONAL EXISTING BUILDING CODE ENERGY CODE COMPLIANCE SUMMARY PROJECT SCOPE INCLUDES LIMITED PRESCRIPTIVE ALTERATIONS TO THE EXISTING BUILDING ENVELOPE AND BUILDING SYSTEMS. ALL NEW OR ALTERED ENVELOPE COMPONENTS TO COMPLY WITH APPLICABLE PRESCRIPTIVE PATH ENERGY CODE REQUIREMENTS PER C402.1.3 & C402.4. NO CHANGES PROPOSED TO SPACE CONDITIONING OR THE AMOUNT OF CONDITIONED SPACE WITHIN THE BUILDING. LIGHTING WILL BE REPLACED AND/OR SUPPLEMENTED WITH HIGH - EFFICIENCY LED FIXTURES AS NECESSARY FOR TENANT USE. LIGHTING CONTROLS IN ACCORDANCE WITH C405.2, LIGHTING POWER PER C405.4. RECEPTACLES TO BE CONTROLLED IN ACCORDANCE WITH C405.10 REQUIREMENTS. 04-14-2023 PLAN REVIEW APPROVED WITH CONDITIONS: 1. SUBMIT FOR A SEPARATE FIRE ALARM PERMIT IF ANY CHANGES ARE MADE TO THE FIRE SYSTEM. 2. FIRE ALARM SYSTEM IS REQUIRED TO BE UP TO DATE WITH REGARD TO ANNUAL CONFIDENCE TESTING. PRIOR TO FINAL INSPECTION OF THIS PERMIT. DFM BURT PARCEL # 27032600100800 TENANT IMPROVEMENT AREA: SUITE B & C 610 5TH AVE S EDMONDS, WA NO SITE ALTERATIONS PROPOSED. i^ = 20'-0" Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. SECTION MATERIAL INDICATIONS I . a. CONCRETE a INSULATION (LOOSE OR BATT) �m ,. _ EARTH INSULATION (RIGID OR SPRAYED) SAND GYPSUM WALL BOARD/PLASTER BRICK/STONE CARPET CONCRETE BLOCK STEEL/METAL PLYWOOD WOOD (FINISH) H � L ACOUSTIC TILE WOOD (FRAMING) WOOD (BLOCKING) A0.1 GENERAL INFORMATION A0.4 CLEARANCE AND MOUNTING HEIGHTS A0.5 LIFE SAFETY PLAN A1.1 EXISTING - DEMO FLOOR PLAN A2.1 FLOOR PLAN LEVEL 1 A2.2 RCP LEVEL 1 A3.0 ELEVATIONS APPROVED ,CLANS MUST BE: ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE CONSTRUCTION TYPE _- VB--------; B OCCUPANCY GROUP ;--------------; --------------- OCCUPANT LOAD 9 ' Separate plumbing and Mechanical permits required. City Of Edmonds Building Department Work TENANT IMPROVEMENT -REMODEL --------------------------------------------------- ---------------------------------------------------- Address 610 5TH AVE S ----------------- Owner IL VIALE Approved Date 04/11 M2_ ------------------------------- Building Official Erik Cater Permit Number;_______________ BLD2023-0327 PROJECT INFORMATION ADDRESS: 610 5TH AVE S, SUITE B EDMONDS, WA 98020-3404 OWNER: IL VIALE - BRIAN TAYLOR AND LOUISE FAVIER ASSESSOR'S TAX PARCEL NUMBER: 27032600100800 LEGAL DESCRIPTION: (SEC 26 TWP 27 RGE 03RT-4B) BEG 350 FT S & 30 FT W OF NE COR NE1/4 NE 1/4 TH W 120 FT TH S 112 FT TH E 120 FT TH N 112 FT TO TPB PROJECT DESCRIPTION: TENANT IMPROVEMENT ALTERATIONS AS REQUIRED FOR NEW BAR / CAFE IN EXISTING BAR / CAFE SPACE. ENGINEERING DIVISION APPROVED AS NOTED 04/12/2023 NO WORK PERMITTED IN THE CITY RIGHT-OF-WAY. ALL STAGING, EQUIPTMENT, MATERIALS, ETC. SHALL BE LOCATED ON PRIVATE PROPERTY. VICINITY MAP S Edmonds Bowl Are ware ' y Ha ewere lm v Ohana Hyperbarics Edmonds Autobody v dmonds Mane Attraction YO Stragic Tempoarily. dosed 1N Communities Group v sll way Howell Way 557 y tcC Miniatures & More Minierores store A Si_. 511 A m 614 T Nomelantl Dr N D 519 X-Ray Northwest fa Medi.I .0 Pply store s 510 a t m (q 5 Barkada Edmonds 1a Filipino - S$ 609 OWNER Brian Taylor & Louise Favier 610 5th Ave S Suite B&C Edmonds, WA 98020 ARCH ITECT URBANAOO A R C H I T E C T S 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM 2023.03.10 PERMIT SUBMITTAL SET CONTRACTOR TBD RECEIVED Mar 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT INFO PROJECT NUMBER: TBD INTAKE DATE: 2023.03.10 11663 REGISTERED 11 >l/ AROHITECT ANDREW oI STATE OF PERMIT STAMP ISSUE # ADD. REVISION DATE SHEET GENERAL INFORMATION A09 1 HORN, STROBE, SPEAKER SWITCH, CARD READER, FIRE N ALARM, LU THERMOSTAT ^ z O m ELECTRICA rn o U LL ,) L DATA O O O DEVICES ON A WALL DEVICES ABOVE RESTROOM COUNTER A002 ACCESSIBILITY -DEVICES 1/4" =1'-0" 2'-6" MIRROR 1'-3" 1'-6" SOAP DISPENSER $ UNO CLEAR SPACE o TA - SINK AND MIRROR TA - SINK PLAN VIEW F71 N J O O Zi M OO 0 O H TA - PAPER TOWEL DISPENSER AND WASTE RECPTICAL 0 o � TA - LAB COAT HOOK BARS A002 ACCESSIBILITY -ACCESSORIES 1/4" = 1'-0" 2'-3" MAX. N in 3'-4" GRAB BARS CONTROLS Z 611 LO GRAB 7 BA S � rn BENCH - O N O ' ' S' - 0" CLR BENCH ROLL IN SHOWER ROLL IN SHOWER A002 ACCESSIBILITY- SHOWERS 1/4" = V-0" 2'-6" 0 URINAL MIN. Q Q SCRE N EQ EQ a z J � O cn O X J Q �O Ln � O i URNIAL MOUNTING HEIGHTS BOLLARD WITH CARD READER AND DOOR SWITCH 3'4" H BOLLARD 0 o , WITH DOOR `n cn ACTUATOR N` SWITCH - DEVICE ABOUT TYP. COUNTER W/SPLAS DOOR ACTUATOR SWITCH INSTALL SO HEIGHEST POINT OF CHANGING TALBE WHEN OPEN IS 32" TA- DIAPER CHANGING STATION 0 in TA - MOP AND BROOM HOLDER MAX. MIN. C7 ro z O � � 00 a M M V) DRINKING FOUNTAIN HEIGHTS 3' - 0" 1' - 6" CONTROLS 10" GRAB BARS BENCH ON Q OPPOSITE WALL N BENCH -I N TRANSFER SHOWER GRAB BARS TOILET PAPER 1' - 6" DISPENSER SEAT COVER DISPENSER SANITARY NAPKIN DISPOSAL O - r-I � i l0 , N N ADA TOILET MOUNTING HEIGHTS ADA TOILET MOUNTING HEIGHTS J U 0 0 o J O o � z O U O TA -SANITARY NAPKIN DISPENSER ir_a:rev Imp :0109110•11 5"- 1' - 3" u allw;a►142I 1111►1reuuv_w 1' - 10" - 611 CONTROLS N 'a 4' - 0" CLR TRANSFER SHOWER 5'-0"CLR MIN. 1' - ADA TOILET PLAIN m FIRE EXTINGUISHER 3'-0" UNO - EQ . EQ TOILET PLAN TOILET PARTITION M FIRE EXTINGUISHER CABINET II Viale OWNER Brian Taylor & Louise Favier 610 5th Ave S Suite B & C Edmonds, WA 98020 ARCH ITECT URBANAOO A R C H I T E C T S 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM 2023.03.10 PERMIT SUBMITTAL SET CONTRACTOR TBD RECEIVED Mar 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT INFO PROJECT NUMBER: TBD INTAKE DATE: 2023.03.10 PERMIT STAMP ISSUE # ADD. REVISION DATE SHEET CLEARANCE AND MOUNTING HEIGHTS URINAL STALL PLAN I A002—ACCESSIBILITY --TOILETS AND URINALS 1/4" = V-0" A08 4 FLOOR PLAN - LEVEL 01 LIFE SAFETY 1/4" = V-0" LIFE SAFETY - EGRESS NOTES: ALL EGRESS DOORS SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 32" ALL DOORS TO REMAIN OPERABLE IN THE DIRECTION OF EGRESS TRAVEL WITHOUT REQUIRING SPECIAL KNOWLEDGE OR KEYS ANY ASSEMBLY OCCUPANCY AREAS SHALL HAVE THE OCCUPANT LOAD OF EACH ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. STAIRWAYS SERVING 50 OR MORE OCCUPANTS SHALL HAVE A MINIMUM CLEAR WIDTH OF 44 INCHES. STAIRWAYS SERVING AN OCCUPANT LOAD OF LESS THAN 50 SHALL HAVE A MINIMUM CLEAR WIDTH OF 36 INCHES. RAISED CHARACTER AND BRAILLE EXIT SIGNS COMPLYING WITH ICC A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR REQUIRING AN EXIT SIGN AND AT ALL EXIT STAIRWAYS AND RAMPS. LUMINAIRES TO BE INSTALLED AT ALL EXIT SIGNS AND EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. SELF LUMINOUS SIGNS TO BE LISTED AND LABELED IN ACCORDANCE WITH UL 924 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. EXTERNALLY ILLUMINATED SIGNS TO BE ILLUMINATED AT AN INTENSITY OF NOT LESS THAN 5 FOOTCANDLES ON THE FACE OF SIGN. ILLUMINATION SHALL BE PROVIDED AT EVERY POINT IN THE MEANS OF EGRESS. UNDER NORMAL POWER, THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL BE NOT LESS THAN 1 FOOTCANDLE AT THE WALKING SURFACE. MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED WITH AN ON -SITE EMERGENCY POWER SYSTEM CAPABLE OF PROVIDING POWER FOR NOT LESS THAN 90 MINUTES. UNDER EMERGENCY POWER, THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL BE NOT LESS THAN AN AVERAGE OF 1 FOOTCANDLE AND A MINIMUM OF 0.1 FOOTCANDLE MEASURED AT THE WALKING SURFACE UPON INITIAL ACTIVATION. ILLUMINATION LEVELS ARE PERMITTED TO DECLINE TO 0.6 FOOTCANDLE AVERAGE AND 0.06 FOOTCANDLE MINIMUM AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. ILLUMINATION SHALL NOT EXCEED A 40:1 RATIO OF UNIFORMITY. REFER TO REFLECTED CEILING PLANS FOR EGRESS LIGHTING LOCATIONS AND ADDITIONAL CRITERIA. PLUMBING DATA: (IBC TABLE 2902.1) REQUIRED FIXTURES: WATER CLOSETS GROUP A-2 BAR (GROUP B OCCUPANCY) 45 OCCUPANTS INSIDE + 34 OCCUPANTS OUTSIDE 1/40 M, 1/40 F LEVEL 01 40(M) OCCUPANTS / 40 = 1 (M) REQUIRED LEVEL 01 40(F) OCCUPANTS / 40 = 1 (F) REQUIRED LAVATORIES GROUP A-2 BAR (GROUP B OCCUPANCY) 45 OCCUPANTS INSIDE + 34 OCCUPANTS OUTSIDE 1/75 LEVEL 01 79 OCCUPANTS / 75 = 2 REQUIRED FIXTURE SUMMARY WC: 1(M) = 1 REQUIRED < 2 PROVIDED* 1 (F) = 1 REQUIRED < 2 PROVIDED* LAVATORIES: 2 REQUIRED = 2 PROVIDED* *SECOND FIXTURE CAPACITY PROVIDED VIA SHARED FACILITIES IN THE BUILDING AS INDICATED IN BUILDING OWNER'S APPROVAL LETTER, INCLUDED WITH THIS PERMIT SUBMITTAL. 311 L" ] 10111:1101C411 I_1014 L*5 SOUTH BUILDING (NON SEPARATED PER 508.3) LEVEL B GROUP B 1,668 SF LEVEL 01 ALTERATION AREA: SUITES B+C GROUP B 1,668 SF NORTH BUILDING (SEPARATED PER 508.4) LEVEL B GROUPS F-1, B 2,064 SF ALLOWABLE BUILDING HEIGHT AND AREA: IBC TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE (TYPE VB, PARTIALLY-SPRINKLERED BUILDING) A, B, & F OCCUPANCIES 40' TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE (TYPE VB, PARTIALLY-SPRINKLERED BUILDING) A-2 2 B 2 F-1 1 SBC TABLE 506.2 ALLOWABLE AREA FACTOR IN SQUARE LEVEL 01 FEET GROUP A-2 2,564 SF (TYPE VB, PARTIALLY-SPRINKLERED BUILDING) A-2 18,000 (SM) B 9,000 (INS) TOTAL BUILDING AREA: 7,964 SF F 8,500 (INS) TOTAL BUILDING AREA (7,964 SF) < MAXIMUM ALLOWABLE AREA OF MOST RESTRICTIVE OCCUPANCY (8,500 SF) OCCUPANCY LEGEND (PROPOSED) SUITE B OCCUPANCY GROUP OCCUPANT LOADS PER SBC TABLE 1004.1.2 B (BAR / CAFE) ASSEMBLY (FIXED BOOTH SEATING) 24"/OCCUPANT +/- 64 LF (BAR SEATING) 18"/OCCUPANT IN, +/- 13.5 LF 41 OCCUPANTS B (KITCHEN) KITCHEN, COMMERCIAL: 200 GSF/OCCUPANT 531 SF 2.7 OCCUPANTS B (OFFICE) BUSINESS AREAS: 150 GSF/OCCUPANT 69 SF 0.5 OCCUPANTS TOTAL OCCUPANT LOAD: 45 PERSONS PER TABLE 1004.5 FIRE EXTINGUISHERS TO BE SIZED AND LOCATED IN ACCORDANCE WITH IBC 906.3 AND NFPA 10 REQUIREMENTS. CABINETS PROJECTING > 4" FROM ADJACENT WALL SURFACES TO BE LOCATED WITH BOTTOM EDGE < 27" A.F.F. ALL COMPONENTS REQUIRING ACCESSIBLE REACH TO BE LOCATED </= 48" & >/= 15" A.F.F. PER ANSI A117.2009 SECTION 308. II Viale OWNER Brian Taylor & Louise Favier 610 5th Ave S Suite B&C Edmonds, WA 98020 ARCHITECT URBANAOO 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM 2023.03.10 PERMIT SUBMITTAL SET CONTRACTOR TBD RECEIVED Mar 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT INFO PROJECT NUMBER: TBD INTAKE DATE: 2023.03.10 11663 REGISTERED ITECT ANDREW OLIVE AW NC STATE OF VVAS IN TOI � 2 PERMIT STAMP ISSUE # ADD. REVISION DATE SHEET A095 0' 2' 4' 8' 16' Q II Viale i i PROPERTY LINE FLOOR PLAN - LEVEL 01 EXISTING -DEMO 1/4" = V-0" GENERAL FLOOR PLAN NOTES 1. ALL DIMENSIONS TO EXISTING WALLS, WINDOWS, DOORS, AND OTHER BUILDING ELEMENTS ARE TO BE CONSIDERED APPROXIMATE, AND ARE TO BE VERIFIED IN THE FIELD. 2. ALL WINDOWS AND DOORS THAT ARE EXISTING, TO BE REPLACED, ARE TO BE VERIFIED IN THE FIELD (MATCH HEIGHT, WIDTH, LOCATION, AND POSITION). CONTRACTOR TO VERIFY ANY DESCREPANCIES WITH ARCHITECT PRIOR TO ORDERING. 3. ALL PLAN DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS "CLEAR" (CLR) AND DIMENSIONS AT EXISTING FINISHED SURFACES TO REMAIN ARE TO FACES OF FINISHED MATERIALS. 4. NO ALTERATIONS TO GRADE, OR GROUND DISTURBANCE U.N.O. 5. ALL INTERIOR STUD WALLS TO BE NOMINAL 2x DIMENSION LUMBER @ 16" OC W/ 5/8" TYPE X GWB ON BOTH SIDES U.N.O. 6. WHERE EXPOSED DURING CONSTRUCTION, EXISTING CEILING OR WALL CAVITIES AT THE BOUNDARY BETWEEN CONDITIONED AND UNCONDITIONED AREAS SHALL BE INSULATED TO FULL DEPTH WITH INSULATION HAVING A NOMINAL VALUE OF R-3.0 PER INCH PER C503.1 ITEM 3. (E) WATE (ABOVE) 2 EXISTING FENCE @ PROPERTY LINE, TO REMAIN A3.0 PLAN LEGEND NEW CONSTRUCTION EXISTING CONSTRUCTION TO REMAIN VT SPACE T SCOPE OWNER Brian Taylor & Louise Favier 610 5th Ave S Suite B&C Edmonds, WA 98020 ARCHITECT ImURBANAOO A R C H I T E C T S 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM 2023.03.10 PERMIT SUBMITTAL SET CONTRACTOR TBD RECEIVED Mar 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT INFO PROJECT NUMBER: TBD INTAKE DATE: 2023.03.10 1\166,3 REGISTERED AROHITECT ANDREW OLIVE Aw NCE STATE OF WAS IN 1ON PERMIT STAMP ISSUE # ADD. REVISION DATE SHEET EXISTING - DEMO FLOOR PLAN 0' 2' 4' 8' 1 6' A 1 a 1 WALK IN COOLER, UNDER SEPARATE PERMIT n u N FLOOR PLAN - LEVEL 01 GENERAL FLOOR PLAN NOTES 1. ALL DIMENSIONS TO EXISTING WALLS, WINDOWS, DOORS, AND OTHER BUILDING ELEMENTS ARE TO BE CONSIDERED APPROXIMATE, AND ARE TO BE VERIFIED IN THE FIELD. 2. ALL WINDOWS AND DOORS THAT ARE EXISTING, TO BE REPLACED, ARE TO BE VERIFIED IN THE FIELD (MATCH HEIGHT, WIDTH, LOCATION, AND POSITION). CONTRACTOR TO VERIFY ANY DESCREPANCIES WITH ARCHITECT PRIOR TO ORDERING. 3. ALL PLAN DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS "CLEAR" (CLR) AND DIMENSIONS AT EXISTING FINISHED SURFACES TO REMAIN ARE TO FACES OF FINISHED MATERIALS. 4. NO ALTERATIONS TO GRADE, OR GROUND DISTURBANCE U.N.O. 5. ALL INTERIOR STUD WALLS TO BE NOMINAL 2x DIMENSION LUMBER @ 16" OC W/ 5/8" TYPE X GWB ON BOTH SIDES U.N.O. 6. WHERE EXPOSED DURING CONSTRUCTION, EXISTING CEILING OR WALL CAVITIES AT THE BOUNDARY BETWEEN CONDITIONED AND UNCONDITIONED AREAS SHALL BE INSULATED TO FULL DEPTH WITH INSULATION HAVING A NOMINAL VALUE OF R-3.0 PER INCH PER C503.1 ITEM 3. 1 A3.0 PLAN LEGEND NEW CONSTRUCTION EXISTING CONSTRUCTION TO REMAIN EQUIPMENT SCHEDULE # DESCRIPTION NOTES 1 HAND WASH SINK VERIFY DIMS TO PROVIDE 30"x42" CLEARANCE CENTERED ON SINK W/O ENCROACHING ON TOILET CLEARANCE 2 FLOOR SINK 3 DUMP SINK 4 THREE COMPARTMENT SINK 5 PRODUCE SINK 6 MEAT / FISH SINK 7 ICE BIN 8 ICE MAKER 9 MOP SINK 10 UNDERCOUNTER DISHWASHER LOW TEMP (AUTO-CHLOR U34 MODEL) 11 MOP SINK 12 SURFACE MT DRIP TRAY W/ GLASS RINSE 13 COLD + HOT WATER DISPENSER 14 UNDERCOUNTER FRIDGE - 2DR 15 SANDWICH PREP REFRIGERATOR 16 UNDERCOUNTER FRIDGE 17 ESPRESSO MACHINE 18 SANDWICH PREP REFRIGERATOR 19 MODULAR WALK-IN COOLER 20 UNDERCOUNTER FRIDGE All operable hardware shall not require tight pinching or grasping and shall comply with ANSI 117.1-2009. DOOR SCHEDULE MARK —PHASE HEIGHT WIDTH NOTES Exterior 06 Existing 6'-8" 3--0" NO CLOSER (TO MAINTAIN ACCESIBILITY) 07 Existing 6'- 8" Interior 01 Existing 6' - 8" 3' - 0" 05 Existing 6' - 8" 3' - 0" 04 New 7' - 0" 3'- 0" NO CLOSER (TO MAINTAIN ACCESIBILITY) Construction WINDOW SCHEDULE NUMBER PHASE WIDTH HEIGHT SILL HEIGHT TEMPERED U-VALUE SHGC NOTES FLOOR PLAN - LEVEL 01 01 New Construction 3' - 8" 6-0" V - 6" YES 0.30 0.38 02 New Construction 3' - 8" 6-0" V - 6" YES 0.30 0.38 * U-VALUES & SHGC ARE MAXIMUMS II Viale OWNER Brian Taylor & Louise Favier 610 5th Ave S Suite B & C Edmonds, WA 98020 ARCH ITECT URBANAOO 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM 2023.03.10 PERMIT SUBMITTAL SET CONTRACTOR TBD RECEIVED Mar 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT INFO PROJECT NUMBER: TBD INTAKE DATE: 2023.03.10 PERMIT STAMP ISSUE # ADD. REVISION DATE SHEET IKole] :M1W_\0l11 kyj:101 0' 2' 4' 8' 16' A291 FLOOR PLAN - LEVEL 01- STORAGE ANALYSIS 1/4" = V-0" GENERAL FLOOR PLAN NOTES 1. ALL DIMENSIONS TO EXISTING WALLS, WINDOWS, DOORS, AND OTHER BUILDING ELEMENTS ARE TO BE CONSIDERED APPROXIMATE, AND ARE TO BE VERIFIED IN THE FIELD. 2. ALL WINDOWS AND DOORS THAT ARE EXISTING, TO BE REPLACED, ARE TO BE VERIFIED IN THE FIELD (MATCH HEIGHT, WIDTH, LOCATION, AND POSITION). CONTRACTOR TO VERIFY ANY DESCREPANCIES WITH ARCHITECT PRIOR TO ORDERING. 3. ALL PLAN DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS "CLEAR" (CLR) AND DIMENSIONS AT EXISTING FINISHED SURFACES TO REMAIN ARE TO FACES OF FINISHED MATERIALS. 4. NO ALTERATIONS TO GRADE, OR GROUND DISTURBANCE U.N.O. 5. ALL INTERIOR STUD WALLS TO BE NOMINAL 2x DIMENSION LUMBER @ 16" OC W/ 5/8" TYPE X GWB ON BOTH SIDES U.N.O. 6. WHERE EXPOSED DURING CONSTRUCTION, EXISTING CEILING OR WALL CAVITIES AT THE BOUNDARY BETWEEN CONDITIONED AND UNCONDITIONED AREAS SHALL BE INSULATED TO FULL DEPTH WITH INSULATION HAVING A NOMINAL VALUE OF R-3.0 PER INCH PER C503.1 ITEM 3. PLAN LEGEND NEW CONSTRUCTION EXISTING CONSTRUCTION TO REMAIN ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST i ON JOB SITE CITY OF EDMONDS BUILDING DIVISION APPROVED PLAN 07/19/2023 ff r i,& Ca4efeor II Viale OWNER Brian Taylor & Louise Favier 610 5th Ave S Suite B & C Edmonds, WA 98020 ARCH ITECT URBANAOO 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM 2023.07.14 MECH PERMIT SUPPLEMENT CONTRACTOR DND DESIGN LLC BLD2023-0796 RESUB Jul 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT P ROJ ECT I N FO PROJECT NUMBER: TBD INTAKE DATE: 2023.03.10 PERMIT STAMP ISSU E # ADD. I REVISION DATE SHEET STORAGE LOADING ANALYSIS A2.1a FOR REFERENCE: JULY 2023 STORAGE LOAD ANALYSIS BASED ON APPROVED FRAMING PLANS FROM PERMIT # BLD20040562 0' 2' 4' 8' 1 6' A2.1a WALK-IN COOLER LIGHTING, PROVIDED BY VENDOR, UNDER SEPARATE PERMIT RCP LEVEL 01 1/4" _ V_0" LIGHTING & ELECTRICAL NOTES 1. ALL LIGHTS TO BE HIGH -EFFICIENCY, DIMMABLE LED, 3,000 KELVIN, CRI >/= 90 U.O.N. 2. ALL DECORATIVE LUMINAIRES TO BE OWNER FURNISHED, CONTRACTOR INSTALLED (OFCI) U.O.N. 3. OCCUPANT SENSOR CONTROLS REQUIRED IN THE FOLLOWING AREAS PER C405.2.1: ENCLOSED OFFICES, ENCLOSED ROOMS 300 FT OR LESS (PANTRY AREA), RESTROOMS, STORAGE ROOMS. OCCUPANT SENSORS TO REDUCE LIGHTING LOAD BY 50% WHEN UNOCCUPOED AND TURN LIGHTING 100% OFF WHEN SPACE IS UNOCCUPIED FOR 20 MINUTES. CONFIGURED TO TURN ON AT 50% POWER EXCEPT IN RESTROOMS, LOBBIES, AND AREAS WHERE SAFETY WOULD BE ENDANGERED. OCCUPANT CONTROL TO ALLOW MANUAL OFF. 4. TIME SWITCH CONTROLS PER C4052.2.2 REQUIRED IN ALL AREAS W/O OCCUPANT SENSOR CONTROLS EXCEPT WHERE LIGHTING IS INTENDED FOR CONTINUOUS OPERATION. TIME SWITCH CONTROLS TO TURN LIGHTS 100% OFF DURING UNOCCUPIED HOURS. PROVIDE OVERRIDE CONTROLS WITH READY ACCESS TO OCCUPANTS SERVING AREAS NO GREATER THAN 5,000 SF. 5. ALL LIGHTING TO HAVE MANUAL CONTROLS WITH READY ACCESS TO OCCUPANTS AND THE ABILITY TO REDUCE THE CONNECTED LIGHTING LOAD TO BETWEEN 30 AND 70 PERCENT. LIGHTING LOAD REDUCTION CONTROLS NOT REQUIRED AT RESTROOMS OR STORAGE ROOMS EXCEPT AS OTHERWISE NOTED. 6. DISPLAY AND ACCENT LIGHTING TO BE CONTROLLED INDEPENDENTLY FROM GENERAL AREA LIGHTING AND OTHER LIGHTING APPLICATIONS WITHIN THE SAME SPACE. SYMBOL LEGEND 8. PROVIDE MASTER CONTROL SWITCH (NOT CIRCUIT BREAKER) TO CONTROL ALL EF EXHAUST FAN DINING/SEATING AREA LIGHTING AT BAR. O SURFACE MOUNT FIXTURE 9. NO 20A CIRCUIT CONTROLLED BY A SINGLE SWITCH OR CONTROL TO BE LOADED >80%. TABLE LAMP 10. PROJECT CLOSE OUT DOCUMENTATION IS REQURIED, INCLUDING WSEC LIGHTING COMPLIANCE REPORTS THAT DOCUMENT ALL INTERIOR AND EXTERIOR LIGHING AREA AND/OR jj WALL MOUNT FIXTURE SURFACE TYPES. LIGHITN POWER ALLOWANCES AND INSTALLED DENSITIES. — — LINEAR SURFACE MOUNT LUMINAIRE C405.4.1 TOTAL CONNECTED INTERIOR LIGHTING POWER TCLP = [LVL + BILL + TRK + POE + Other] LVL = LINE VOLTAGE LAMPS, MIN 60 LUMENS/WATT BILL = RATED INPUT WATTAGE OF BALLAST TRK = TRACK LIGHTING LUMINAIRES AS SPECIFIED, NO LESS THAN 16W/LF OR WATTAGE LIMIT OF CURRENT LIMITING DEVICES, OR WATTAGE LIMIT OF TRANSFORMER POE= MAX WATTAGE OF TRANSFORMER EXCEPT THAT FOR POE, POWER SUPPLIED TO ANY NON - LIGHTING DEVICES MAY BE SUBTRACTED Other = WATTAGE OF ALL OTHER LUMINAIRES EXCLUSIONS FROM TCLP CALCULATION: • EMERGENCY LIGHTING AUTOMATICALLY OFF DURING NORMAL BUILDING OPERATION • ADVERTISING OR DIRECTIONAL SIGNAGE • FOOD WARMING LIGHTS • LIGHTING APPROVED BECAUSE OF SAFETY CONSIDERATIONS • FURNITURE MOUNTED SUPPLEMENTAL TASK LIGHTING THAT IS CONTROLLED BY AUTOMATIC SHUTOFF • EXIT SIGNS INTERIOR LIGHTING POWER ALLOWANCE, BUILDING AREA METHOD (WATTS/FTZ) • DINING BAR LOUNGE/LEISURE = 0.79 0.79 WATTS / FT x 1,668 FT = 1,318 WATTS TOTAL ALLOWABLE • L1 - SURFACE MOUNTED DECORATIVE PENDANT LUMINAIRE (6) @ 20W = 120 • L2 - SURFACE MOUNTED LUMINAIRE (13) @ 15W = 195 • L3 - WALL MOUNTED VANITY LIGHTING (1) @ 50W = 50 • L4 - TABLE LAMPS (13) @ 10W = 130 • L5 - SURFACE MOUNTED UTILITY LUMINAIRES (6)@ 50W = 300 TCLP = 795 WATTS 795 WATTS ACTUAL < 1,318 WATTS ALLOWABLE II Viale OWNER Brian Taylor & Louise Favier 610 5th Ave S Suite B&C Edmonds, WA 98020 ARCHITECT URBANAOO 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM 2023.03.10 PERMIT SUBMITTAL SET CONTRACTOR TBD RECEIVED Mar 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT INFO PROJECT NUMBER: TBD INTAKE DATE: 2023.03.10 R PERMIT STAMP ISSUE # ADD. REVISION DATE SHEET RCP LEVEL 1 7. WHEE TOTAL LIGHTING POWER DENSITY OF EGRESS LIGHTING IS >0.02 W/SF FIXTURES REQUIRE SHUT OFF DURING UNOCCUPIED PERIODS. 0' 2' 4' 8' 1 6' A292 II Viale A B C D FFF J F -I �_ JL JL _JL_ —� -1 I J I � _ J- _J _ JL _— EXISTING ELEVATION - EAST 1/4" = V-0" A B C PROPOSED ELEVATION - EAST 1/4" =1'-0" DEMO (E) OVERHEAD DOOR, TO BE REPLACED D (N) WINDOWS AT EXISTING FRAMED OPENING, PER SCHEDULE LOOR PLAN _LEVEL 01 0'-0" LOOR PLAN - LEVEL 01 0'-0° OWNER Brian Taylor & Louise Favier 610 5th Ave S Suite B & C Edmonds, WA 98020 ARCH ITECT URBANAOO A R C H I T E C T S 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM 2023.03.10 PERMIT SUBMITTAL SET CONTRACTOR TBD RECEIVED Mar 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT INFO INTAKE DATE: 2023.03.10 PERMIT STAMP ISSUE # ADD. REVISION DATE SHEET ELEVATIONS 0' 2' 4' 8' 16' A390