REVIEWED BLD2023-0327+Interior_Lighting_Summary+3.10.2023_9.59.21_PM+3415529Firefox https://waenergycodes.com/print_project_ summary_form.phr7k=nWOQMTV5f1T1QmZnZpP...
BLD2023-0327
LIGHTING COMPLIANCE SUMMARY
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl Administered by: 02023 NEEA, All rights reserved
Project & Applicant
Information
Project Title
Il Viale - 2018 WSEC
For Building Department Use: Date: Mar 11, 2023
RECEIVED
Mar 17 2023
C ITV OF EDMONDS
Project Address
610 5th Ave S
B+C
Edmonds, WA 98020
Applicant Name
Andrew Lawrence
Applicant Phone
206-274-8020
DEVELOPMENT ERVICES
DEPARTMENT
Applicant Email
aawrence@urbanadd.com
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
General Occupancy
All Commercial
General Building Use Type
Dining, Restaurant/Bar
Building Cond. Floor Area
1,668
General Project Types
Alteration
New Building or
Addition
Lighting Scope
g g P
Alteration
Lighting Scope
Interior Lighting
Project Cond. Floor Area
1,668
Floors Above Grade
2
Compliance Method
Compliance Method 1 -General
Lighting Project Description
Tenant improvement alterations to support new bar and espresso cafe in existing restaurant/bar space. New high -efficiency lighting to fit altered layout.
Lighting Compliance Scope
Project Type(Interior
iInterior / Exterior
ncludes both interior & parking)
Luminaire Replacement Scope
Compliance Method
LPA Calculation
Adjustment
Compliance Verification
and Method
Alteration
Interior Lighting
50% or more replaced
Building area
No Calculation Adjustments allowed
COMPLIES
Additional Efficiency
Options Included
Project Title Il Viale - 2018 WSEC Date Mar 11, 2023
Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES
Compliance Method Building area LPA Calculation Adjustment none
Interior Lighting Power Allowance - Building Area
Building Areas
Gross Interior Area (SF)
LPA (Watts/SF)
Total Watts Allowed
Total Proposed Watts
Compliance Status by
(SF x LPA x 1)
By Building Area
Building Area
Dining - Bar/lounge/leisure
1,668
0.79
1,318
795
COMPLIES
Proposed Lighting Power Density
Watts per
Total Watts
Fixture Type/Application
Fixture ID
Building Area
New or
Quantity of Fixtures CLDs or
Fixture, or
Total Linear
Watts per Linear
Proposed
Existing -to -Remain
Luminaires (#F)
Luminaira (WpF)
Feet (LF)
Foot (WpLF)
(#F x WpF) or
(LF x WpLF)
Individual Fixtures
Horizontal surface -mount
L2
Dining - Bar/lounge/leisure
New
13
15
195
Horizontal surface -mount
L5
Dining - Bar/lounge/leisure
New
6
50
300
Suspended
Ll
Dining - Bar/lounge/leisure
New
1 6
1 20
1
1
1 120
Task lighting
L4
Dining - Bar/lounge/leisure
New
13
10
1
130
Wall -mounted
L3
Dining - Bar/lounge/leisure
New
1
50
1
50
Project Title
Il Viale - 2018 WSEC
Date
Mar 11, 2023
Proposed Fixtures Details
ALTERATION - INTERIOR LIGHTING (50% or more replaced)
Fixture Type/Application
Fixture ID
Location in Documents
Lamp Type
Building Area
New or
Existing -to -Remain
Individual Fixtures
I of 2 3/10/2023, 8:57 PM
Firefox
https://waenergycodes.com/print_project summary_fonn.php?k=aWQ9MTY50DQmZnZpP..
Horizontal surface -mount
L2 I A2.2
LED
Dining - Bar/lounge/leisure
New
Fixture Description: SURFACE MOUTNED LUMINAIRE
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Horizontal surface -mount
LS I A2.2
LED
Dining - Bar/lounge/leisure
New
Fixture Description: SURFACE MOUNTED UTILITY LUMINAIRES
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Suspended
Ll A2.2 I
LED
Dining - Bar/lounge/leisure
New
Fixture Description: SURFACE MOUNTED DECORATIVE LUMINAIRE
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Task lighting
L4 T A2.2
LED
Dining - Bar/lounge/leisure
New
Fixture Description: TABLE LAMPS
Are these fixtures located within a daylight zone?: Yes, applying exception for controls
Daylight sensing controls exception applied: Ultra -low total LPD (< 35% of total LPA)
Do these fixtures require specific application lighting controls?: None required
Wall -mounted
L3 F A2.2
LED
Dining - Bar/lounge/leisure
New
Fixture Description: WALL MOUNTED VANITY LIGHT
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
2 of 2 3/10/2023, 8:57 PM