APPROVED BLD RESUB2 BLD2021-0801+Architectural SITE_Plan+2.18.2022_2.00.39_PM+2690591GONTRAGTOR TO VERIFY ALL LOT AND BUILDING DIMENSIONS BEFORE FROGEEDIN& WITH GONSTRUGTION FPIIIFAIINI�111 MWO W05111, PG A-1 SITE PLAN - RENI )ERIN65 PG A-2 ELEVATIONS PG A-3 ELEVATIONS - FOUNPATION PG A-4 FLOORPLANS - SECTION 0 rN MYamN4LE ► LL(I IlJI�S` 5` 11 SITE P LAN PARCEL # 00434205503400 SCALE: 1 " = 10'-0" N THE NCBDC BOARD OF EXAMINERS, HAVING QUALIFIED BY EXAMINATION, CONFIRMS BY USE AND SIGNATURE OF THE NCBDC PROFESSIONAL SEAL ON THIS DOCUMENT, P4 Affm ,4wde4dm IS RECOGNIZED AS A, Certified Professional Building Designer WITH ALL RIGHTS AND PRIVILEDGES ATTENDANT THERETO AS A MEMBER OF THE, National council of BuildinggDesigner Certification m� �� O zc`v� p 0 0 � z OHO Q oz m r- ILIm z Z N W Q LU MEMBER A I B'DR A'S+L-MOAN INKTITUTE of RTTTT.TITNG DESIGN cERTIFlED PROF6N 1AIL L BUILDING DESIGNER • NATIONAL COUNCIL OF • PATE: JUNE 10, 2021 REV15EP: 5EFT 5. 2021 AUTHORIZATION AND RIGHT TO PRACTICE AS PROVIDED UNDER THEA-1 w PROVISIONS OF RCW 18.08.410, PRACTICE OF ARCHITECTURE, CHAPTER OF EXEMPT AREAS OF PRACTICE WA. ST. LEGISLATURE, 1985 GONTRAGTOR TO VERIFY ALL LOT AND BUILDING DIMENSIONS BEFORE FROGEEDIN& WITH GONSTRUGTION F05T TO E w/FLAT R< SOUTH ELEVATION (EXISTING) SCALE: 1 /4" = V-0" METAL 5TA SEAM ROC 51DIN6 TO MATC 3/4 x 10" (EXF.) NEV 5GALE: 1/4" = V—OII m� m DL z ul tS)Q- zc`v� �� p 0 �Q0 m v � rN z OHO Lu Q <m 3 1 m U)Im z Z NZk W Q N z 0 } w w MEMBER A I B'DR AMY-IUCAN TNKTIT'UTE of RTTTT.TITNG DESIGN CERTIFIED PROF6N 1AIL L BUILDING DESIGNER • NATIONAL COUNCIL OF • DATE: JUNE 10, 2021 REV15EP: 5EFT 5, 2021 A-2 GONTRAGTOR TO VERIFY ALL LOT AND BUILDING DIMENSIONS BEFORE FROGEE171N& WITH GONSTRUGTION . ... . ... .. • MAX. 18" O.G. d WITHIN 12" OF 2x6 HF FRAMING CORNER, 7" MIN. 1/2" PIA. x 10" A.B. @ 16" O.G. EXI5TIN& (RETRO FIT) EXISTING 4" CONCRETE SLAB 12" #4 REBAR STU55 DRILLED AND EPDXIED INTO EXI5TIN6 WALL 8 FTC, W/ 4" MIN EMBEDMENT NEW FND/FTG EXI5TING TO NEW CONNECTION DETAIL / N.T.5. 0 / NEW 6" FND WALL $ FOOTING \ W/BUCKOUT FOR SLAB PASSOVER 1'-4 1/2" 16'-3" 1'-4 1/2'' 19' FOUNDATION PLANT SCALE: 1/4" = 1'-O" 1/2" GDX PLYWOOD or 7/16" OSB GRADE 4"SOLID PIPE TO STORM SEWER 2x4" P.T. MUD SILL 1/2" PIA. x 10" A.B. MAX. 18" O.G. & WITHIN 12" OF CORNER, 7" MIN. EMBEDMENT 4" REINF. GONGRETE SLAB #4 REBAR @ 24" O.G. #4 CONT. REBAR (HORIZONTAL) �I 4" PERF PIPE SET I I � 2 - #4 GONT.REBAR IN DRAIN ROCK 14„ OAR AO �N17 1 /2 EXISTING SER I REMODEL OARAOE EXIST CARPORT I EXISTING SER EAST ELEVATION (NEW) SCALE: 1/4" = 1'—O" EXISTING SER . REMODEL OARAOE SER COW u 3 w Q m� �0 0 zc`v� p 0 � z OHO I Q o 7- m ��m Z N W Q MEMBER A I BDR AMY-IUCAN 1N5'1ITUTE of RTTTT,DTNG DESIGN cERTIFlED —F681— BUILDING DESIGNER • NATIONAL COUNCIL OF • �G 2 O O Cos � C ci o" DATE: JUNE 10, 2021 REVISED: SEPT 5. 2021 A-3 CONTRACTOR TO VERIFY ALL LOT AND BUILDING DIMENSIONS BEFORE PROGEEDIN& WITH GONSTRUGTION GARAGE REMODEL SCALE: 1 /4" = V-O" EXISTII, POST E AND Pc 2x6 IN—F FRAMIN( NEW FTC w/STEM SEGTION SCALE: 1 /2" = V-OII A w TING T BASE POST � IN —FILL &,MING =TG =M WALL m� O m ul zc`v� m � rN z OHO Q oz m ��m Z N W Q MEMBER A I B'DR A'S+L-MOAN TNKTIT'UTE of RTTTT.TITNG DESIGN CERTIFIED PROF6N 1AIL L BUILDING DESIGNER • NATIONAL COUNCIL OF • PATE: JUNE 10, 2021 REV15EP: 5EPT 5, 2021 A-4 FEZ FOUNDATION PLAN SCALE: 1 /4" = 1' - 0" SIMPSON HDU2 OR STHD14 PER DETAIL E/S 1. LRP SHEARWALL PLAN SCALE: 1 /4" = 1' - 0" XISTING CARPORT =OUNDATION, TYP. STEM L/FOOTING PER \IL A/S1 FRAME BETWEEN POSTS W/ 2X6 DF/HF� STUDS @ 16" O.C. U Vj 04 MANUFACTURED 04 o TRUSSES @ 24" O.C. o x I I x H9'-0") 4X12 DF#2 GARAGE DOOR HEADER NOTE TO TRUSS COMPANY: GABLE END TRUSS IS DROPPED 5.5" TO ACCOMMODATE OUTLOOKERS. DEE DETAIL'D' ON THIS SHEET. ROOF FRAMING PLAN SCALE: 'I /4" = 1'- 0" SHEAR WALL LEGEND PER SHEAR WALL TABLE, S1 SHEARWALLS ARE PW, PRESCRIPTIVE SHEAR WALL, UNLESS NOTED OTHERWISE. 7/16" OSB OR PW = 15/32" PLY ON ONE SIDE OF WALL, UNBLOCKED, 8d NAILS AT 6" O.C. ALONG EDGES, 12" O.C. IN THE FIELD. HOLD DOWNS ARE NOT REQUIRED. ANCHOR BOLTS REQUIRED PER TYPICAL DETAIL BELOW. LATERAL RESTRAINT PANEL PER LATERAL RESTRAINT PANEL DETAIL'E', S1. SIMPSON HDU2 OR STHD14 PER DETAIL E/S 1. LRP SHEAR WALL TABLE SHEATHING ON EDGE NAILING / MIN. THICKNESS LATERAL RESISTANCE (PLF) WALL PANEL SHEATHING ONE OR BOTH EDGES BLOCKED NAIL SIZE FIELD NAILING LOAD TRANSFER OF EDGE SIDES OF WALL OR UNBLOCKED O DISTANCE (MAX) O MEMBERS &SILL PLATE WIND SEISMIC PW �16" OSB OR 1V32" ONE UNBLOCKED 8d 6" / 12" O.C. NO 2X (NOMINAL) 300 240 PLY 1 4 10 PLY = CDX, C-C, OR C-D PLYWOOD. OSB OF SIMILAR THICKNESS AND SPAN RATING MAY BE SUBSTITUTED FOR PLYWOOD. 02 NAILS SHALL BE COMMON OR GALVANIZED BOX, UNLESS NOTED OTHERWISE. 3 FOR WALLS DESIGNED TO HAVE LOADS TRANSFERED AROUND THE WINDOW OPENINGS, DOUBLE STUDS MUST BE PLACED ON EITHER SIDE OF EACH WINDOW WITH EDGE NAILING ALONG BOTH STUDS. ® NO HOLD-DOWNS ARE REQUIRED FOR THIS SHEARWALL NOTES: (1) AS AN ALTERNATIVE TO THE SSTB20 HOLD-DOWN ANCHOR BOLTS, USE $" ALL-THREAD/THREADED ROD A-307 WITH A MINIMUM EMBED OF 10". USE SIMPSON EPDXY -TIE BOLT SYSTEM WITH "SET" HIGH STRENGTH EPDXY. CONCRETE MUST BE AT LEAST 7 DAYS OLD. (2) UNLESS NOTED OTHERWISE, ALL EXTERIOR WALLS SHALL BE CONSTRUCTED IN ACCORDANCE WITH PW (PRESCRIPTIVE WALL). (3) ALL CONNECTIONS NOT SHOWN ABOVE, SHALL CONFORM TO IBC TABLE 2304.10.1. A*-]2X SINGLE TOP END OF [PLATE OPTIONAL HEADER HEADER PER PLAN SYM . MSTC28 STRAP FASTEN ALL SHEATHING TO w HEADER WITH 8D NAILS IN A 3" Q w GRID AS SHOWN AND 3" O.C. IN 0-o ALL FRAMING (STUDS AND SILLS). J z (2) 2X STUDS � d oo 1/2" OSB OR PLY SHEATHING w J ON BOTH SIDES OF WALL p 0- PANEL SPLICE (IF NEEDED) X O SHALL OCCUR WITHIN 24" OF w w MID -HEIGHT. (2) 2X BLOCKING Q IS REQUIRED FASTEN C� BLOCKING TOGETHER WITH z 16D NAILS @ 3" O.C. Q w0 16 CD/OSB $" DIA. X 10 ANCHOR 2X6 STUDS @ 16" O.C. BOLTS @ 48" O.C. 7" MIN. EMBEDMENT INTO CONC. #4 CONT. AT TOP OF STEM WALL 4" CONC. SLAB 6" MIN. /\ 4" DIA. FOR VERTICAL AND / TIGHT LINE z HORIZONTAL REBAR, SEE REBAR TABLE jG (2) #4 CONTINUOUS / 4" DIAMETER REBAR IN BASE OF `� PERFORATED DRAIN FOOTING 5 16" 5 PIPE SET IN GRAVEL GARAGE 24" LONG #4 REBAR EPDXIED MIN. 4" INTO EXISTING FOUNDATION STEM WALL. ] v ° Q. ° d � v d . NEW FOUNDATIO ROWS OF 16D ILS @ 3" O.C. OSB OR PLY HEATHING EQUIRED ON DTH SIDES SIMPSON HDU2 OR STHD14 HOLD DOWN PER PLAN •• o 2X6 BLOCK ON TOP OF SILL PLATE Ak 2X6 PT SILL PLATES SSTB20 OR 5/8"X16" THREADED ROD DRILLED & EOPXY'D W/ 8" EMBED. g" DIA. A.B. 7" a MIN EMBED. a 16t, ° SECA-A A (EILATERAL RESTRAINT PANEL SCALE: 1/2" = V-0" ANCHOR BOLTS 1. 05/8"X10" LONG @ 48" O.C. MAX. 2. MIN. 2 PER SILL. 3. WITHIN 12" FROM SILL END. 1-3/4" 4. 3"X3"X1/4" SQUARE WASHER FOR ANCHOR BOLTS, TYP. MIN. U OK TO DRILL & EPDXY TO EXISTING FDN. EMBED MIN. 7" ANCHOR BOLTS TO SILL PLATE EXISTING FOUNDATION v (2) 24" LONG #4 REBAR EPDXIED MIN. 4" INTO EXISTING FOOTING. #4 REBAR WITHIN TOP 6" OF WALL HORIZONTALS VERTICALS - ALTERNATE HOOK DIRECTION (2) #4 CONTINUOUS HORIZONTALS IN FTG. HEIGHT'H' IN VERTICAL HORIZONTAL FEET REINFORCING REINFORCING QTY. (1) #4 0' - 2' #4 @ 4' O.C. WITHIN 6" OF TOP OF WALL 2'- 4' #4 @ 24" O.C. #4 @ 24" O.C. Q 4'-6' #4@12"O.C. #4@12"O.C. 1Q FOOTING FOR 4' - 6' FOUNDATION TO BE 24" WIDE X 8" THICK AND STEM WALL TO BE 8" WIDE. REBAR TABLE 2X BLOCKIN SIMPSON H1 E EACH TRUSS TOP OF FULL LENGTH SHEATHING TRUSS/RAFTER EN = EDGE NAILING, 8d NAILS @ 6" O.C. BN = BOUNDARY NAILING, 8d nails @ 12" O.C. TYPICAL WALL TO ROOF CONNECTION CONNECT CDX PLY TO TOP CHORD WITH 10d @ 6" O.C. CONNECT TOP CHORD OF END TRUSS TO WALL WITH (1) 1/4"X4-1/2" SIMPSON SIDS SCREWS @ 16" O.C. INTO EACH STUD FLASHING REQUIRED 1/2" CDX CONNECTED WITH 10d NAILS AT 6" O.C. ALONG EDGES, 12" O.C. IN THE FIELD TRUSS PER PLAN END TRUSS TOP CHORD SCALE: N.T.S. 2X4 BLOCKING AT 8' O.C. ROOF SHEATHING (4) 12d NAILS-\ (2) 12d NAILS TRUSS C MIAR] (2) 12d NAILS 24" MIN. SIMP. H1 @ EACH OUTLOOKER (2) #10X4" LONG WOOD SCREWS 2X4 BLOCKING AT 8' O.C.J (4) 12d NAILS-/ SIMPSON A23 @ 32" O.C. 36" MAX. 8d NAILS 2X6 D.F.2 @ 24" O.C. @6"O.C. OUTLOOKERS ON EDGE ,2X BARGE NAIL TO EACH OUTLOOKER WITH (2) 16d NAILS DROP END TRUSS 5.5" FOR OUTLOOKERS GABLE END TO BE SHEATHED WITH 7/16" OSB OR 15/32" PLY UP TO BOTTOM OF OUTLOOKER. END NAIL 8d @ 6" O.C. `2X4 DIAGONAL BRACING AT 8' O.C. \-END NAIL 8d @ 8" O.C. —2X6 STUD WALL NOTE: GABLE END TRUSS BOTTOM CHORD TO BE 5-1/2" LOWER TO ALLOW FOR 2X6 D.F. OUTLOOKERS ON EDGE SCALE: 3/4" = 1'-0" DROPPED END TRUSS z Q W Y 0 W U' 0 z J Z Q I I �0 5 �U Q � N W C ti I I Q p N N T_ z 0 67 T_ N W > W W N p > W m � } LLJ p} m W m J p N W Z) uJ Q � Q N W Y 0O� W Lu i Z= U m 0� m J r — N p W Q W U a_ 2� z� I� o� cl) 2 0 = U O v M Z w c- fI� v 2 N 00 O 0-) Z CD00 Z� z 0 a W ao0W U U U _ Z H .-. Z c — WccC� w Z a. CZ LJJ z Z or-LU W a W Z QY z W W 0>_J fn J Z v z— Z W (D W m Z U 2 100 W z 0 } 06@� � J Lu >- W W Lu � N J W JJJLO0 OQL 5. � m � �Nm WJS J p}tip ^ — ('1nLu W m p m� p � m 0 z O_ Q U_ LL U L1J 0- U) J Q U U O U) Q Q � Q o z U) >_ ui z �_ > O o Ljj N ti W Q z O 0 L1J DRAWING TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE S1 of 2 STANDARD STRUCTURAL SPECIFICATIONS - 2018 IRC INTRODUCTION The Standard Structural Specifications are guidelines and structural requirements for construction of typical residential structures. The intent of this document is to provide general structural requirements for the project. Builder, contractor, and other parties involved are required to read this document and are responsible for meeting the requirements specified within. Contact the engineer of record with any questions or concerns. DESIGN CRITERIA J DESIGN PARAMETER VALUE SOURCE Q Seismic Design Category 'D1' IBC 1613 W Risk Category fill IBC Table 1604.5 Wind Exposure Category 'B' IBC 1609.4.3 Q Basic Wind Speed (3-second gust) 110 MPH IBC Figure 1609.3(1) Design Wind Load 16 PSF ASCE 7-16 28.6-1 LOAD SOURCE LIVE LOAD DEAD LOAD J Roofs 20 psf 15 psf Q V Floors 40 psf 12 psf Decks & Balconies 60 psf 10 psf ry Ground Snow Load 25 psf - LJJ Exterior Wall - 12 psf Interior Wall - 10 psf Interior Partition - 8 psf Minimum uniform live loads come from 2018 IRC Table R301.5 DEFLECTION LIMITS STRUCTURAL MEMBER LIVE+DEAD Roof (with flexible ceiling) L/240 Roof (with brittle ceiling) L/360 Rafter with slopes greater than 3:12 without ceiling L/180 Floor Members L/360 Horizontal Deflection (with flexible finish) L/360 All other structural members L/240 The above maximum deflection limits are required by 2018 IRC Table R301.7 Higher limits (less deflection) may be used at the engineer's discretion. REFERENCE CODES & STANDARDS • International Residential Code, IRC 2018 • Washington State Building Code, SBC 2018 • National Design Specification for Wood Construction, NDS 2018 • Wood Frame Construction Manual, WFCM 2018 • Building Code Requirements for Structural Concrete, ACI 318-19, • Minimum Design Loads for Buildings And Other Structures, ASCE 7-16 • Steel Construction Manual, 15th Edition, AISC 2015 GENERAL REQUIREMENTS Codes: All materials and work shall adhere to the minimum requirements of the Reference Codes & Standards listed above. Contractor shall be responsible to comply with OSHA, State Labor, and Industry Standards. Contractor assumes full responsibility of construction methods used, safety provisions employed, and the finished condition of the structure. Construction Personnel: Only competent personnel familiar with construction and safety practices relevant to the project should be employed to assemble and construct the work. Construction Methods and Project Safety: The project drawings and specifications represent the finished structure and do not indicate methods, procedures, or sequence of construction. The builder must take necessary precautions to maintain and ensure the integrity of the structure during construction. Bradley Engineering, Inc. will not enforce safety measures or regulations, nor will the owner or designer. Therefore, the contractor shall design, construct, and maintain all safety devices and follow all pertinent regulations. Temporary Support: The builder must provide adequate temporary support to all walls, roofs, beams, and floors during construction. Design of these supports are not included unless specifically shown. Contractor is responsible for the adequacy of all temporary support systems. Specifications: All notes, call -outs, and details included within this design package are required unless specifically noted otherwise. Verification: Verify all dimensions, elevations, and site conditions before starting work. Errors: The contractor is responsible to check the plans and site conditions and to notify the architect/designer/engineer/owner of any errors or omissions prior to the start of construction. Conflicts: Notes and details on the structural drawings take precedence over the Standard Structural Specifications and typical details. Written dimensions take precedence over scaled drawing dimensions. Structural notes and details on the structural drawings take precedence over the architectural drawings. Changes: Written approval from the engineer of record is required for any structural changes to the provided drawings. Changes may be made 'in the field' with consent of Bradley Engineering. Please provide a red -lined drawing or sketch of desired change(s) to provide context and applicable information prior to contacting engineer. Please contact the engineer who performed the engineering for your project as noted on this drawing. The engineering for this project was completed by T. HRUBY whose phone number is (360) 815-0863. Substitutions: If connector or lumber product substitutions are desired, contractor shall provide manufacturer's evaluation reports of proposed substitutions to the engineer/owner for approval. Member Size: The member dimensions (e.g. depth and width of beams, columns, etc.) specified in these drawings are structural minimums. It is acceptable to increase the size above what is specified. Similar work: Where construction details are not shown or noted for any part of the project, the area shall be constructed in the same manner as similar work shown on the drawings. Modification of Structural Members: Cuts, notches, and holes bored in trusses, structural composite lumber, glue -laminated members, or I -joists are prohibited except where permitted by the manufacturer's recommendations or as shown on this page. (See ALLOWABLE HOLES) Scope of Work: The scope of work of Bradley Engineering, Inc. is limited to the structural engineering and analysis pertaining to the subject structure. Bradley Engineering, Inc. takes no responsibility for items not specifically addressed in the drawings, calculations, or call -outs. Completion of Work: Submittal of these structural drawings to the client completes the present scope of work and budget of Bradley Engineering, Inc. Other consultation, design, calculations, sketches, inspection, etc. after submittal of this report shall be billed on an hourly basis. STRUCTURAL STEEL Grade: Unless noted otherwise, the grade of steel members is as follows: • Wide flange(W).................................................. ASTM A992 Steel Fy = 50 ksi Fu = 65 ksi • HSS Tube (HSS)................................................. ASTM A500, Grade B or better. Fy = 46 ksi Fu = 58 ksi • Channels, plates, angles ..................................... ASTM A36, Fy = 36 ksi Fu = 58 ksi. • Bolts................................................................... ASTM A325 or better • Anchor bolts ....................................................... ASTM F1554 or better • #4 Rebar & Smaller ............................................ Grade 40 (Fy = 40 ksi or better) • #5 Rebar & Larger .............................................. Grade 60 (Fy = 60 ksi or better) Connections: Unless noted otherwise, steel to steel connections to be 1/4" continuous fillet weld. All structural steel to be fabricated in accordance with the AISC manual of steel construction, latest edition. Welding: Steel welding to be done using E70 electrodes, and conform to AWS D1.1, latest edition. Washers: Provide standard washers under all nuts and anchor bolts FOUNDATION • Design Soil Bearing Pressure = 1,500 psf • Frost Zone Depth = 18 inches • Unless noted otherwise, concrete is designed with 2,500 psi strength and does not require special inspection. The specified concrete strength (3,000 psi) is greater than design strength (2,500 psi) Code: Cast -in -place concrete sizing, placing, and testing shall conform to ACI 318-19 and ACI 301-16 Geotechnical Report: Bradley Engineering strongly recommends that a geotechnical report be performed by a qualified geotechnical engineer for all land based construction projects. If this information is not supplied, footings are designed for 1,500 psf soil bearing pressure. Earthwork: Call before you dig! Call '811'. Locate and protect underground conduit, plumbing, and utilities where work is performed. Footings shall bear on undisturbed native soils and/or structural fill compacted in lifts of one foot or less to 95% of a modified proctor per ASTM D1557. Soils shall be firm and unyielding. All organic and deleterious material beneath the footings, foundations, and slabs to be removed and replaced with 4" min. compacted granular fill to 95% relative compaction. Structural Fill: Structural fill consists of clean, well -graded sandy gravel, gravelly sand, or other approved naturally occurring granular material (e.g. pit run) with at least 30 percent retained on the No. 4 sieve, or a well -graded crushed rock. In wet weather conditions, fill should have less than 5% fines. Soils with an over -optimum moisture content should be scarified (i.e. turn over the soil) and dried during periods of dry weather or replaced with drier structural fill. Surface Drainage: Finished grades are to be at least 6" below top of stem wall. Lots shall be graded to drain surface water away from foundation walls. The grade shall fall a minimum of 6 inches within 10 feet. If 6 inches of fall is not possible, grade shall be sloped min 2 percent away from the building. Footings: All footings shall conform to accompanying structural details. Specified footing dimensions are minimums unless noted otherwise. Bottom of footings to be below frost zone (18"). Footing Drains: Providing adequate drainage to retaining and basement walls is imperative. Footing drains shall be provided at the base of all footings and retaining walls which will have earth placed against them. Washed drain rock must extend to within one foot of finished grade. Footing drains shall be 4" perforated pipe routed down gradient to daylight, unless otherwise specified. Concrete: Mix and 28 day strength unless noted otherwise: • Concrete compressive strength, fc = 3,000 psi (fc shall be evaluated at 28 days or 56 days for fly ash/slag) • Concrete exposed to weather shall have air entrainment of 6% (+/-1.5%) • Maximum water / cement ratio = 0.50 • 25% max fly ash... 50% max slag Lifts: Concrete lifts shall be poured within 60 minutes of the previous lift Temperature: Pour concrete at temperatures of 40 degrees and above. Reinforced Concrete: Place all reinforcing per plans, details, and applicable code requirements. Lap all continuous bars 48 X bar diameter minimum. For a typical continuous #4 bar (diameter = 0.5") the rebar lap is equal to 48 X 0.5" = 24" minimum. Reinforcing bars, bolts, anchors, etc shall be securely tied in position prior to concrete placement. Reinforcing steel shall be free of rust and coatings. Anchor Bolts: Provide 5/8" diameter x 10" long wet -set or expansion anchor bolts @ 4' O.C. and within 6-12" of corners with 3"x3"x0.229" square washers. 7" minimum anchor bolt embedment required. Adhesive Anchors: Unless noted otherwise, epoxy anchors in concrete with Simpson SET-XP or Hilti HIT-HY 200-R or equivalent epoxy, installed per manufacturer's guidelines. For extreme temperature applications, when long-term temperature exceeds 110°F or is less than 0°F, use Simpson Set-3G. Waterproofing: Waterproof all basement walls and slabs on grade. It is highly recommended to use asphalt waterproofing sealer or Eucon Vandex AM-10 crystalline admixture. These waterproofing agents shall be installed per the manufacturer's recommendations. At cold -joints, water -stops are highly recommended. SLAB ON GRADE Control Joints: Control joints (expansion, cold, or saw -cut) at 8'-12' O.C. required to mitigate shrinkage cracking. Rebar or woven wire mesh (if installed) shall break at all control joints. Saw -cut joints within 12 hours of pour. Garage Slabs: Unless noted otherwise, garage slab shall be 4" concrete slab over 10 mil poly vapor barrier over 4" compacted granular fill. Rebar or woven wire mesh is optional unless specifically required: OK to use #3 rebar at 24" O.C. each way or 6x6xW4 woven wire mesh. Living Area Slabs: Unless noted otherwise, interior slabs shall be 4" concrete slab over 10 mil poly vapor barrier over 2" rigid insulation (where insulation is required) over 4" compacted granular fill. Reinforcing: Reinforcing bars or woven wire mesh shall be placed 1-1/2" above the bottom of the slab. Curing: Use water or membrane cure immediately after initial set for a minimum of 7 days. For water cure, hose it down and keep it wet. For membrane curing, wet the concrete then cover with an impermeable membrane (e.g. visqueen) or liquid membrane curing compound. Provide shade for concrete during curing. Drainage: Garages, porches, and surfaces that are required to drain shall be sloped 1/8" per 1' or 1/4" per 1' Concrete Topping: Concrete topping can not be installed on floors unless specifically detailed on the structural drawings. The concrete topping shall be installed per manufacturer's specifications. The topping shall not exceed 1-1/2" in thickness and shall be less than or equal to 18 psf (i.e. >-12 psf per inch). Non -Bearing Interior Wall to Slab Connection: Interior walls shall be connected to concrete slab with minimum 1/2"x5-1/2" long anchor bolts @ 6' O.C.. Wet -set, epoxied, expansion, or screwed (Simpson Titen HD) anchor bolts are accpetable. If interior wall is not specifically denoted as a shear wall, it is acceptable to use 1/4"x4" split pins @ 32" O.C. or 1/4"x4" Titen screws @ 32" O.C. CRAWL SPACE Vapor Barrier: Cover entire crawl space with class I vapor retardant (i.e. poly vapor barrier - 6 mil required, 10 mil highly recommended). Extend 6" up foundation walls minimum. Access: Access shall be provided to all under -floor spaces. Access openings through the floor shall be a min 18 inches b 24 inches. Openings throw h a perimeter wall shall be min 16 inches b 24 inches. Y9 p Y Foundation Ventilation: Provide min 1 square foot of crawl space ventilation per 150 square feet of crawl space area. Space vents evenly to provide cross ventilation. Cover with $" corrosion resistant mesh screen. THICKER FLANGE WIDTH ALLOWABLE HOLES - I -Joists & I -Rafters Minimum distance from hole to support. See Table A below Up to 1-1/2" hole may be cut anywhere out -side of hatched zone. For holes larger /No holes in than 1-1/2" diameter, refer to Table A flange of I -Joist n, 6, ElO ❑ O 6„ 6" Lt 2 x D1 Di Closely grouped round LZ 2 x LZ �D2 No holes in minimum holes are allowable if the minimum hatched zones group meets requirements for round or square holes Table A - Minimum Hole Distance From Support JOIST DEPTH TJI Rating.. (Flange Width) ROUND HOLE SIZE RECTANGULAR HOLE SIZE 2" 3" 4" 2" 3" 4" 9y2„ 210 (2-1/16") 1'-0" 1'-6" 2'-6" 1'-0" 2'-0" 2'-6" 360 (2-5/16") 1'-6" 2'4" T-0" 1'-6" 2'-6" T-6" 210 (2-1/16") 1.4. 1'-6" 2'-0" 1'-0" 1'-6" 2'-6" 11Y..360 (2-5/16") 1'-6" 2'-0" T-0" 1'-6" 2'-6" T-6" 210 (2-1116") 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2'-0" 14" 360 (2-5/16") 1'-0" 1'-0" 1'-6" 1'-0" 1'-6" 2'-6" • DO NOT, under any circumstances, cut or notch joist flanges (don't even think about it) • Leave Y8" of web (minimum) at top and bottom of hole (i.e. do not cut within 1/8" of flange ) • Round or rectangular holes allowed according to Table A • 1-1/2" max hole size in cantilever • Ok to cut web in a similar fashion for any manufacturer's I -Joists. For Table A, Use Flange Width instead of TJI Rating May want to refer to joist manufacturer's specifications and requirements JOIST CONVERSION CHART Trus Joist Pacific Woodtech Boise Cascade Roseburg Red Built LP TJI 210 PWI47 BC16000 RFP1400 Red-145 LP1530 TJI 360 PWI70 BC160 RFP170 LP136 PWI77 RFP170 Red-165 TJI 560 PWI90 BC190 RFP190 Red-190 LP156 OK to substitute the joists specified on drawings (TJI's) with joists listed in this table. Match the original depth and spacing. OK to use thicker flange width than specified (e.g. use TJI 360 instead of TJI 210) WOOD FRAMING Default Wood Types: Unless noted otherwise, the material for a structural member is as shown: • Beams, Posts, & Sawn Joists ............. Douglas Fir #2 (D.F.2) • Studs & Plates ................................... Hem/Fir (H.F.) or Douglas Fir (D.F.) • Blocking ............................................. Any solid 2X or rim joist material • Rim Joists .......................................... Douglas Fir #2 (D.F.2) for solid sawn, manufactured rim for I -joists • Glued -Laminated (dry -use) ................ D.F. 24F-V4 (GLB) • Exposed Structural Members ............ Pressure Treated (P.T.) • Glued -Laminated (wet -use) ............... Treat with Hi -Clear 11 by Permapost Products Co. in Hillsboro, OR Moisture Content: The max moisture content shall be 19% at the time of installation of connectors, nails, and bolts for framing members. Pressure Treated Lumber: All members in contact with earth/concrete or exposed to the elements shall be pressure treated or preservative treated (P.T.). Colorless end sealer shall be applied immediately to the ends of members after fabrication and field trimming. Glulam beams (GLB's) which are exposed to the elements shall be treated with Hi -Clear 11 by Permapost Products Co located in Hillsboro, OR. Blocking: Provide 2X or engineered lumber full depth solid blocking between joists and rafters at beam and bearing wall locations. Blocking is required at all bearing locations. Trusses, structural composite lumber, glued -laminated members, and I -joists shall be supported laterally as required by the manufacturer's recommendations. Bearing: For beams bearing on perpendicular walls or columns, Use a minimum 2-1/2" bearing length unless noted otherwise. Use enough studs to match or exceed beam width unless noted otherwise. Headers: Unless noted otherwise, headers to be 410 D.F.2, (2) 2x10 D.F.2, or 6x8 D.F.1 Glued Laminated Members: Glulam beams (GLB) shall be Douglas Fir -Larch, 24F-V4, dry use only Engineered Lumber: Engineered lumber offers certain structural advantages over conventional sawn lumber. All engineered lumber must be APA approved. Install per the aforementioned codes and relevant manufacturer's installation guides for each type: • Wood I -Joists: Used extensively in floor and roof framing (Trus Joist TJI's typically specified) • Laminated Veneer Lumber (LVL): Minimum modulus of elasticity E = 2.0x10^6 psi • Parallel Strand Lumber (PSL): Minimum modulus of elasticity E = 2.0x10^6 psi • Laminated Strand Lumber (LSL): Minimum modulus of elasticity E = 2.0x10^6 psi LVL Option to GLB and PSL's: Multi -ply LVL beams may be used in lieu of PSL or GLB, provided that they are installed according to International Beams' Technical Bulletin TB-LVL-2 • Multi -ply LVL's shall be fastened together with min (3) rows 1/4" self -tapping screws @ 18" O.C., 1.5" minimum embedment required in all members. • (3) rows of 1/2" diameter through bolts @ 24" O.C. with 1/2" washers on each side is acceptable. • The width and height of the multi -ply LVL beam must be equal or greater than the corresponding dimensions called out for the respective GLB or PSL beam. Solid Sawn Lumber Option to I -Joists: Solid sawn lumber may be preferred over I -joists due to cost or other reasons. The following solid sawn lumber options may be used in lieu of engineering I -Joists (e.g. TJIs) without approval from the engineer of record. Maintain original spacing (e.g. 12", 16", or 24" O.C.) • 2x10 D.F.2's may be used in lieu of 9.5" TJI 210's • 2x12 D.F.2's may be used in lieu of 11-7/8" TJI 210's Wood Structural Panels: American Plywood Association (APA) rated sheathing is required for all wood structural panels. Unless noted otherwise, the wood panel for each situation is: • Roof Sheathing: 1/2" CDX (plywood with moisture resistant glue - highly recommended), CD (plywood), or 7/16" OSB (oriented strand board), with ply clips or T&G (tongue and groove). Nail with 10d nails at 6" O.C. along edges, 12" O.C. in the field, no blocking required • Prescriptive Exterior Wall Sheathing: 7/16" OSB or 15/32" CD ply, 8d nails at 6" O.C. along edges, 12" O.C. in the field, no blocking required. All exterior walls to be sheathed per prescriptive requirements noted above unless explicitly noted as a shearwall • Prescriptive Interior Wall Sheathing: 1/2" Drywall (Gypsum Wall Board - GWB), screwed with 1-1/4" Type W or S screws at 7" O.C. along edges, 7" O.C. in the field • Floor Sheathing: 3/4" CD or OSB, nailed with 8d nails at 6" O.C. along edges, 12" O.C. in the field. glued with construction adhesive prior to nailing, no blocking required (unless noted otherwise) Shear Walls: See shear wall plans and shear wall table for sheathing grade, thickness, and nail spacing. Stairs: Refer to R311.7 for stair framing and other requirements Advanced Framing: Unless specifically approved by the engineer of record, advanced framing is not allowed. Advanced framing may be a cost-effective and structurally adequate alternative to conventional framing, but additional precautions must be taken. Advanced framing shall conform to the construction standards outlined in APA's Advanced Framing Construction Guide (available on www.apawood.org). Studs at Opening: Refer to table R603.7(1) to determine the number of jack and king studs required at each end of an opening. Refer to table R603.7(2) for connection requirements. Exterior Stud Walls: Use 2x6 studs @ 16" O.C. unless noted otherwise. 2x6 exterior stud walls are typically desirable for insulation/energy code reasons (i.e. not structural reasons). Interior Walls: Minimum 2x4 studs @ 16" O.C., unless required for plumbing/utility reasons Wood Stud Holes & Notching: For wood studs 12' and less, it is permissible to cut notches and holes per the following requirements. Notch/hole size shall not exceed the following max percentage of stud width: • Bearing walls: Hole - 40% of total stud width, Notch - 25% of total stud width • Non -bearing walls: Hole - 60% of total stud width, Notch - 40% of total stud width • In all cases, hole edges must be at least 5/8" from edge of the stud • OK to drill up to 1" diameter hole for studs up to 16' tall. Hole to be 5/8" from edge of stud. • See IRC Figure R602.6(1) for visual description of stud holes & notching DECKS & BALCONIES Guardrails: Unless noted otherwise and detailed, guardrails to meet R312.1. Guardrails shall be 36" high min with max opening size so that a 4" sphere cannot pass through. Guardrails shall be designed to withstand a 200 lb point load applied in any direction and at any location on the top rail and shall be designed to withstand a uniform load of 50 Ib/ft applied horizontally to the top rail. Contractor/owner/inspector to physically verify (e.g. push & pull on top rail) that the guardrails meet the IRC loading requirements mentioned above. Attachment to House: All deck s. ledger connections shall conform to the details outlined on structural drawings. g For decks over 30 above grade, deck tension ties are required: g q • DTT2Z - (1) at each end of the deck (2 total) • DTT1Z - (4) equally spaced along the length of deck Hot Tubs on Decks: DO NOT INSTALL HOT TUBS ON DECKS unless specifically designed for hot tub. Waterproofing: Bradley Engineering is not responsible for adequacy of waterproof membranes on decks which cover living space. STAIRWAYS Stairs: Refer to R311.7 for stairway requirements Handrails: Unless noted otherwise and detailed, handrails to meet R311.7.8. ALLOWABLE HOLES - Solid or Eng. Lumber No holes in 8X diameter of the Ok to completely - hatched areas largest hole (min) Allowable remove this area rL/8- i 8X hole zone �—L/8- FD/2 D/14 D � D/2 O O DA L/4 L/2 L/4 L Hole Size: The hole diameter should not exceed 2" or 1/10 the beam depth, whichever is smaller. - �2 • These guidelines are applicable to glued -laminated, solid sawn, and engineered lumber (beams, headers, joists, rafters, etc) • Uniform loads only, no point loads • Round holes only • No holes in cantilevers • DO NOT cut, notch, or drill holes in headers or beams except as indicated in sketch ABBREVIATIONS (Used throughout structural drawings) (E) Existing C.S. Clear Span INT. Interior STD Standard (N) New DBL Double MAX Maximum STR'L Structural A.B. Anchor Bolt EA. Each MANUF. Manufacturer S.S. Select Structural ARCH Architectural ELEV. Elevation MIN Minimum T.O. Top Of BLDG Building EXT. Exterior N/A Not Applicable TJI Trus Joist, I Series BLKG Blocking FDN Foundation O.C. On Center TPL Triple BM Beam FTG Footing Opp. Opposite TYP. Typical BTM Bottom GALV. Galvanized PLY Plywood U.N.O. Unless Noted Otherwise C C Channel (Steel) GA. Gauge P.T. Pressure Treated V.B. Vapor Barrier CL Center Line HDR Header REINF. Reinforced VERT. Vertical CMU Conc. Masonry Unit HORIZ. Horizontal REQ'D Required W/ With CONC. Concrete HSS Hollow Structural Section SIM. Similar W/O Without CONT. Continuous INSUL. Insulation SPECS Specifications WF Wide Flange (Steel) RnnF_q Manufactured Trusses: Unless stick framing is specified on structural drawings, wood trusses are to be engineered by a truss manufacturer. If truss layout is not provided by truss manufacturer, the engineer assumes that trusses all bear on exterior walls and do not bear on interior walls. Trusses and truss connections/hard-ware to be in accordance with truss manufacturer's requirements. Do not modify or cut trusses without approval of truss manufacturer. Girder Trusses: Truss manufacturer to be responsible for placement of girder trusses. Install girder truss LGT tie down or SDWC15600 screws to secure girder trusses as detailed on structural drawings. Number of studs supporting girder truss to match plies of girder (e.g. 3-ply girder truss to bear on minimum 3 studs). Lateral Bracing: Contractor to install lateral bracing in roof as specified by truss manufacturer. Over -framing: Unless noted otherwise over -framing to be 2X6 @ 24" O.C. Overframing to be bear directly on top of truss below. See rafter span chart below for max spans. Manufactured truss overframing is acceptable. Access: Attic access shall be provided per R807.1. The rough framed opening size shall not be less than 22"X30" and shall be located in a hallway or other readily accessible location. Headers: Bearing wall headers to be 4X10 or 6X8 D.F.2 min (double 2x10 or triple 2x8 OK). FRAMING CONNECTORS Manufacturer: Simpson Strong -Tie construction connectors are specified, however, any nationally recognized brand (e.g. Silver, KC, etc) may be used provided that they are equivalent in their ability to carry all applied loads in all orientations. Installation: All prefabricated items shall be installed in strict accordance with the manufacturer's recommendations and requirements (locations, exposure, end and edge distances, fasteners, etc.). Simpson Connectors: Unless noted otherwise on the structural drawings and details, the following Simpson Strong -Tie construction connectors shall be used: • Post Caps: CBTZ, PCZ/EPCZ, BC/BCS, CC, CCQ, ECC, ECCQ • Post Bases: CPTZ, CBSQ, PB/PBS, ABA/ABU/ABW • Joist Hangers: LUS/LU/U/HU/HUC, JB, HUTF/HUSTF (top -flange) • I -Joist Hangers: IUS/MIU, ITS/MIT/HIT (top -flange) • Beam Hangers: HU/HUC/HUCQ/HGUS, LEG/MEG/EG (top -flange) • Rafter Hangers: LSU/LSSR/LSSJ, LRUZ • Truss and Rafter Connection: H1, H2.5A, or SDWC15600 at each heel to double plate • Holdowns: HDU/DTT with SSTB, STHD14, STHD14RJ Floor -to -floor Strap -Ties: HDU2, MST48 Fastener Requirements: The number and size of fasteners connecting wood members shall not be less than that set forth in IRC Table R602.3 (fastening schedule) Exposure: Any hardware or fasteners exposed to the elements or pressure treated lumber shall be heavy duty galvanized or stainless steel in accordance with IRC 317.3 Staples: For roofs, floors and walls, the IRC permits 16 gage wire staples with a min 7/16" dia. crown (per Table R602.3(1) footnote b). SPAN TABLES Please use the members specified on the structural drawings. Owner/contractor may substitute these members in lieu of the originally specified members. The following joist and rafter span charts may be used to specify member sizes, provided that the relevant loading conditions (below) are met. For questions on interpreting the charts or for members which do not satisfy the charts' loading conditions, contact the engineer of record. FLOOR JOIST OR BEAM BEARING WALL BEARING WALL OR BEAM OR BEAM CLEAR SPAN (C.S.) DEFINITION OF CLEAR SPAN: DISTANCE FROM INSIDE OF BEARING POINT TO INSIDE OF OPPOSITE BEARING POINT (i.e. UNSUPPORTED DISTANCE) ENGINEERED I -JOIST (TJI) SIZING MAX CLEAR SPAN WITH 5/8" GYPSUM TJI JOIST MEMBER MAX CLEAR SPAN WITHOUT GYPSUM TJI JOIST MEMBER 15'-5" 9-1/2" TJ 1 210 14'-2" 9-1/2" TJ 1 210 18'-5" 11-7/8" TJ 1 210 1 T-1 " 11-7/8" TJ 1 210 19'-8" 11-7/8" TJ 1 360 18'-6" 11-7/8" TJ 1 360 20'-5" 14" TJ 1 210 19'-4" 14" TJ 1 210 2 V-7" 14" TJI 360 20'-5" — 14" TJI 360 22'- " 16" TJI 21 2 '-1 " 16" TJI 21 Assuming 4" Plywood glued and nailed to top surface. Gypsum and no gypsum bottom surface option is given above Loading conditions: Live load = 40 psf; dead load = 10 psf; L/480; TJ Pro Rating = 42, Dry -use; 16" O.C. spacing SOLID SAWN MAX CLEAR SPAN JOIST SIZING 2X SAWN MEMBER 5'-6" 2X4 D.F.2 8'-9" 2X6 D.F.2 1 V-6" 2X8 D.F.2 14'-9" 2X10 D.F.2 17'-6" 2X12 D.F.2 19'-6" 2X14 D.F.2 DECK JOIST SIZING MAX CLEAR SPAN 2X SAWN MEMBER 5'-0" - 2X4 P.T. 7'-6" 2X6 P.T. 10'-0" 2X8 P.T. 12'-9" 2X10 P.T. 15-9" 2X12 P.T. 18'-0" 2X14 P.T. Loading conditions: Live load = 40 psf; dead load Loading conditions: Live load = 60 psf; dead load = 10 psf; = 10 psf; L/480; Dry -use; 16" O.C. spacing L/360; Wet -use; 16" O.C. spacing; No tapered joists! MAX CLEAR SPAN D.F.2 ROOF RAFTER SIZING 2X SAWN MAX CLEAR SPAN MEMBER D.F.2 TJI RAFTER MEMBER 6'-10" 2X4 D.F.2 19'-0" 9-1/2" TJI 210 10'-4" 2X6 D.F.2 22'-3" 11-7/8" TJ 1 210 13'-2" 2X8 D.F.2 25'-0" 11-7/8" TJI 360 16'-3" 2X10 D.F.2 24'-3" 14" TJI 210 18'-10" 2X12 D.F.2 28'-6" 14" TJI 360 2 '-11" 2X14 D.F.2 2 '- " 16" TJ 1210 Loading conditions: Snow load = 25 psf; dead load = 10 psf; L/240; Dry -use; 24" O.C. spacing W CO Z Q Y 0 W O Z U JO Z > p � 2 0U m Q � N W C\1 N 0 N � N � Z O U) N W > d W > } om 0 } } W } m } W w N 0 0f 0}0 co0 Lu 0 N N W WO� Z) LU Y Q � OO� Q - u W � Z= U m � co LU J- Q N Z F..: LU = U 0 W U Q U) 2 ZO U U W Z W Z ZW (DW ZZ (D UJ Z W w W J J o C) 0� Qm m U) Z 0 Q U_ LL U w W J NQN U N) VJ 0 Q 0 Z W rn N 0 rn O Q U Z Q Z 1:� Z W Z_ W J z J W 0 LU CO Z a \ >_I--- >-W W J � 0 Qcou?m cif 3: U Lu r� p >}o> 0 co M 0 �U) 0 2 i0 co Z COC w G LJJ CV ti S2 of 2 = O 11­_U O v 11­- M O� Z o Z Z in r W a co W 11­- ,Z Wok W to a- �Z W W Q W Q :06 Q V 2 im (n 11.-:Z J W OQ� � UF_ W J 5UQ C O W LLa0 DRAWING TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE