Loading...
REVIEWED RESUB1 BLD2021-0801+Structural_Analysis_or_Calculations+12.20.2021_1.24.18_PM+2583179Page 1 of 11 Structural Calculations Whitney Carport 729 Edmonds St Edmonds, WA 12/15/2021 Page(s) Contents 2 Reference Codes & Standards 3-11 Structural Analysis CV O CV N The engineers seal and signature above indicates that the engineer of record assumes full responsibility for the subject structure. Structural drawings S1 through S2 have been signed and sealed by the engineer of record and represents a required element of the building specifications. This structure was engineered per the 2018 IBC/IRC requirements. Note: This structure meets BOTH the 2015 IBC/IRC and the 2018/2015 from a structural standpoint. Notes, Disclaimers: • Bradley Engineering, Inc. takes no responsibility for items not specifically addressed within this report set. • This report is valid only for the specific project shown above and herein. BRADLEY ENGINEERING, INC. 811 Yew St. Bellingham, WA 98229 Ph. (360) 752-5795 Page 2 of 11 REFERENCE CODES & STANDARDS L�-c FtiG ti International Residential Code, IRC 2018 Washington State Building Code, SBC 2018 --�� National Design Specification for Wood Construction, NDS 2018 Building Code Requirements for Structural Concrete, ACI 318-19 Minimum Design Loads for Buildings and Other Structures, ASCE 7-16 Steel Construction Manual, 15th Edition, AISC 2015 North American Standard for Cold -Formed Steel Structural Framing, AISI 2015 Ed. TABLE 1: LATERAL DESIGN CRITERIA Design Parameter Value Source Seismic Design Category DI IBC 1613 Risk Category II IBC Table 1604.5 Wind Exposure Category B IBC 1609.4.3 Basic Wind Speed 110 mph IBC Figure 1609.3(1) Design Wind Load 16.00 psf ASCE 7-10 28.6-1 TABLE 2: VERTICAL DESIGN CRITERIA Load Source Live Load Dead Load Roof Diaphragm 20 psf 15 psf Floor Diaphragm 40 psf 12 psf Decks & Balconies 60 psf 10 psf Ground Snow Load 25 psf - Roof Snow Load 25 psf - Exterior Wall - 12 psf Interior Wall - 10 psf Interior Partition - 8 psf TABLE 3: DEFLECTION LIMITS Structural Member Live Snow Live + Dead Roof (plaster ceiling) L/360 L/360 L/240 Roof (non -plaster ceiling) L/240 L/240 L/180 Roof (not supporting ceiling) L/180 L/180 L/120 Floor Members L/360 - L/240 Horizontal Deflection (any case) - - L/200 Farm Buildings & Greenhouses - - L/180 Long Spans (>20 feet) - - L/480 Sliding Glass Doors - - L/600 II Note: The above minimum deflection limits are based on the 2018 IRC Table R301.7. Higher deflection values may be used at the engineer's discretion to improve performance Page 3 of 11 SCE AMERICAN SOCIETY OF CIVIL ENGINEERS Address: 729 Edmonds St Edmonds, Washington 98020 ASCE 7 Hazards Report Standard: ASCE/SEI 7-16 Elevation: 88.31 ft (NAVD 88) Risk Category: II Latitude: 47.812346 Soil Class: D - Default (see Longitude:-122.371357 Section 11.4.3) r'. , -.. r I I. - K L tlell tit G Edmonds A ruin s< Sha .` EAruer�on l rMk I,smna center ro plc }Vay L_ _I lnl nLd Wind Results: Wind Speed 98 Vmph 10-year MRI 67 Vmph 25-year MRI 74 Vmph 50-year MRI 78 Vmph 100-year MRI 83 Vmph Q, L,I i,�:•: I :I, ..•:.ICI'= I I i Data Source: ASCE/SEI 7-16, Fig. 26.5-1 B and Figs. CC.2-1—CC.2-4, and Section 26.5.2 Date Accessed: Wed Dec 15 2021 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane -prone region as defined in ASCE/SEI 7-16 Section 26.2. https://asce7hazardtool.online/ Page 1 of 3 Wed Dec 15 2021 Page 4 of 11 -ASCE® AMERICAN SOCIETY OF CIVIL ENGINEERS Seismic Site Soil Class: D - Default (see Section 11.4.3) Results: Ss : 1.287 Sol N/A S, 0.453 TL 6 Fa 1.2 PGA: 0.548 FV N/A PGA M : 0.657 SMs : 1.545 FPGA 1.2 SM1 N/A le 1 SIDS 1.03 Cv 1.357 Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Data Accessed: Wed Dec 15 2021 Date Source: USGS Seismic Design Maps https://asce7hazardtool.online/ Page 2 of 3 Wed Dec 15 2021 Page 5 of 11 -ASCE® AMERICAN SOCIUY OF CIVIL ENGINEERS Snow Results: Elevation: Data Source: Date Accessed: Wed Dec 15 2021 In "Case Study" areas, site -specific case studies are required to establish ground snow loads. Extreme local variations in ground snow loads in these areas preclude mapping at this scale. Ground snow load determination for such sites shall be based on an extreme value statistical analysis of data available in the vicinity of the site using a value with a 2 percent annual probability of being exceeded (50-year mean recurrence interval). Site is outside ASCE/SEI 7-16, Table 7.2-5 boundaries. For ground snow loads in this area, see SEAW Snow Load Analysis for Washington, 2nd Ed. (1995). Structural Engineers Association of Washington, Seattle, WA. Statutory requirements of the Authority Having Jurisdiction are not included The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third -party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third -party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. https://asce7hazardtool.online/ Page 3 of 3 Wed Dec 15 2021 Page 6 of 11 Lateral Analysis Address: 729 Edmonds St Edmonds, WA Wind Analysis - Calculation of Wind Loads Inputs Wind Speed, V 110 mph Height, H 7.25 feet Roof Angle 9.5 degrees Exposure Category B Horizontal Pressure Zone A ASD Load Comb. Factor, PAS, 0.6 Topographic Factor, Kzt 1 Risk Category II Date: 12/15/2021 S/W User: T. Hruby Risk Category: Low risk to human life in event of failure II Most small residential structures III Substantial risk to human life in event of failure IV Crucial to human life Horizontal Pressure Zone: A End zone of wall B End zone of roof C Interior zone of wall D Interior zone of roof Exposure Category: B Areas closely surrounded by obstructions C Open terrain and scattered obstructions D Flat unobstructed areas or close to large body of water Calculate A (ASCE 7-16 Figure 27.3.1) Height (ft) Exposure B Exposure C Exposure D 0 1.00 1.21 1.47 15 1.00 1.21 1.47 20 1.00 1.29 1.55 25 1.00 1.35 1.61 30 1.00 1.40 1.66 35 1.05 1.45 1.70 40 1.09 1.49 1.74 45 1.12 1.53 1.78 50 1.16 1.56 1.81 55 1.19 1.59 1.84 60 1.22 1.62 1.87 Calculate simplified design wind pressure PDesign = 11 * Kzt * PS30A = 21.36 psf Reference ASCE 7-16, Chapter 26 Calculate Ps30 (ASCE 7-16 Figure 28.6-1. V = 110 mph) Roof Angle Zone A Zone B Zone C Zone D 0 19.2 -10 12.7 -5.9 5 19.2 -10 12.7 -5.9 10 21.6 -9 14.4 -5.2 15 24.1 -8 16 -4.6 20 26.6 -7 17.7 -3.9 25 24.1 3.9 17.4 4.0 30 21.6 14.8 17.2 11.8 60 21.6 14.8 17.2 11.8 Ps30A = 21.36 psf Use ASD Load Combination 7 7. 0.6D + 0.6W Apply ASD Load Combination Factor Paso = 0.6 P= PASD *PDesign = 12.82 psf Design wind pressure shall not be less than 16 psf. (2015 IBC 1609.6.3) P = 16.00 psf Page 7 of 11 Seismic Analysis Address: 729 Edmonds St Date: ######### S/W User: T. Hruby Calculation of Seismic Loads ASCE 7-10 12.14.8 Simplified Lateral Force Analysis Procedure: An equivalent lateral force analysis shall consist of the application of equivalent static lateral forces to a linear mathematical model of the structure. The lateral forces applied in each direction shall sum to a total seismic base shear given by Section 12.14.8.1 and shall be distributed vertically in accordance with Section 12.14.8.2. For the purpose of analysis, the structure shall be considered fixed at the base. Inputs Seismic Category D Number of Stories One Story Risk Category II Structure Type Light -Frame Wood -Sheathed Walls Soil Type Stiff Soil, D (typical) Base Snow Load * 30 psf Ss ** 1.096 g F*Sos*W V= R ( ASCE 7 — 10, 12.14 — 11) Calculations Fa, Acceleration -based Site Coefficient 1.4 F, Structure Height Coefficient 1 R, Response Modification Coefficient 6.5 S DS, Seismic Design Parameter 1.023 g Seismic Snow Load* 0 psf 2*Fa*Ss SpS = ,, (ASCE 7 — 10,12.14.8.1) * Snow load required to be in seismic calculation if snow load is > 30 psf. Snow load analysis for Washington, 2nd ed. by Structural Engineers Association of Washington recommends using 25% of base snow load to be used in seismic calculations due to statistical probability theory. ** Seismic design parameter Ss is determined from U.S. Seismic Design Maps (link below) https://earthquake.usgs.gov/designmaps/us/application.php? Dead Loads to Roof Diaphragm Load Source Load (psf) L (ft) W (ft) A (sq ft) DL (Ibs) Roof 15 500 7500 Roof -Snow 25 500 12500 Comparison of Wind and Seismic Forces Direction North/South East/West Wind tributary length, ft 7.25 7.25 Wind tributary height, ft 9.5 11 Wind tributary area, sq ft 68.875 79.75 Wind Pressure, psf 16.00 16.00 Design wind load, lb 1102 1276 Design seismic Load, lb 3147 3147.5 Governed by: Seismic Seismic Roof Sesmic Loads Roof Weight, Wr 20000 Ibs Roof Shear, Vr 3147.5 Ibs Therefore, Seismic loads govern lateral analysis for North/South resisting walls. Furthermore, Seismic loads govern lateral analysis for East/West resisting walls. Page 8 of 11 Seismic Analysis - Calculation of Shear Wall Loads Wall Location: First Story Description: E&W Walls Shear Wall Calculations Story Shear, Vtot = 3147 lb Load resisted by first story walls Fp = Lp *300plf= 0 lb Load resisted by prescriptive/interior walls FS = Vtot - Fp = 3147 lb Load resisted by shear walls PLFShear = Fa/Ls 177 plf Shear Wall Load (pounds per length foot) Resisting Shear Wall (ft) Shear Wall Case 11 Shear Wall, Lx 7.75 ft Case 1: Conventional O.K. PLF . 300 10 ft Case 2: SW4 & HDU2's 300 < PLF 685 0 Case 3: SW5 or SW8 & HDU2's 685 < PLF 980 0 Case 4: SW5 & HDU8's 980 < PLF 1400 0 Case 5: Other sheathing methods required 1400 < PLF - 2435 0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF 0 0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted in LS = E Lx 17.8 ft accordance with SPDWS Section 4.3. Shear wall aspect ration shall not exceed 3.5:1. If Pres. Wall, LP 0 requirements are not met portal framing methods can be used. Summary: East & West walls are Case 1, adequately braced by conventional sheathing. No special shearwalls or hold-downs required. The lateral resistance provided by conventional sheating is structurally adequate to resist the tributary lateral loads imposed on them without additional lateral resistance provided by shearwalls and hold-downs/strap-ties, etc. Page 9 of 11 Lateral Restraint Panel LRP Location: Garage Door Opening Description: Lateral Due to Seismic Seismic Force P = 16.00 psf Wind Pressure from Wind Analysis page 1 Fseis = 3147 Ibs Roof Shear From Pg. 2 of Lateral Analysis The APA portal -frame design described in APA TT-10OF can be used in engineered applications which require shear transfer via moment resisting frame. Cyclic testing has been conducted on the APA portal -frame design (APA 2012). Recommended design values for engineered use of the portal frames are provided in Table 1. Design values are derived from the cyclic test data using a rational procedure that considers both strength and stiffness. Aspect ratio requirements of the IRC/IBC do not apply to the wall seqments of the APA Table 1: Design Values for APA Portal Frame Width (inches) Height (ft) Ultimate Load (Ibs) ASD Design Value (Ibs) 16 8 2,780 1,000 10 2,180 600 24 8 4,720 1,700 10 3,630 1,000 Calculate Force Resisted by LRP Width of Panel Height of Panel 18 inches 7 feet Number of Panels 2 panels (2 typical) Panels sheathed on both sides? Yes First interpolation, height = 8' 1175 pounds per 8' frame First interpolation, height = 10' 700 pounds per 10' frame Second Interpolation, Design Load 1412.5 pounds per design frame Load Resisted by LRP, FLRP 5650 pounds total Check if Fwind < FcRP Yes Summary: Garage Door Walls are adequately restrained by Lateral Restraint Panel per APA Portal Frame Guide. Install lateral restraint panel per detail 'E', S1. Install 7/16" OSB on both sides of wall with 8d nails at 3" O.C. in all framing. Extend sheathing completely over header. Use (1) Simpson HDU2 connected to double studs on each side of portal frame. Page 10 of 11 Bradley Engineering, Inc. 811 Yew St. Bellingham, WA 98229 CANS RUCTIONCALC Important: Top and bolkxn trust be laterally supported at supports and at 4-h max Intervals. Dynamo loading not considered. Corrolant with 2018 IBC. Al designs should be checked by a competent professional. Al users shall corroy with State Engineering Law. Injury and I or death can reauh from improper use of this product. Job Name: Whitney Carport Beam I.D.: Garage Door Header Other Info.: Main Span, L = 16.00 ft Main Span Max. Allowed Live Defl: L / 360 o.11In Main Span Max. Allowed Total Defl: L / 360 = os0 n Cantilever (Overhang) Exists? No Pitch if Sloped: Load Duration u."00 Loads From Continuous Member? Np r�K etio 0¢P� �eea'tic Load and Span Diagram (root To scale. Pitch, lfany, not shown) 150 100 50 0 2 4 6 8 10 12 14 13 18 -50 -100 -150 _ Add Self Wt.? yes O No For Wood and Press Treated? Wet Cord? Temp Cord. Sawn Member Repetitive Use? rvo Glul-amsOnly: Nptgesstrvatad ® 100dog F$Ie0 Uniform Loads Over Full Length of Member Allow Live Load Red'n? Roof Loads (not including snow) Roof Snow (only) Deck Loads Floor 2 Loads Floor Loads Wall Dead Load Other'psf load and trib. width Additional'plf Unif. Live Loads. Additional'plf Un'rf. Dead Loads. Roof pitch for U. Red'n Beam type for U. Load Subtotals Red'n Total Adjusted Uniform Loads 0.0:12 A,-d-beams Combined Total Uniform Load 4x And Smaller (Lumber) Lumber Material Douglas fir-lamh(North) Lumber Grade No.1/No.2 Acceptable Solutions (4)2x 10 (2)2x 12 3x14 List properties for what (3) 2 x 10 4 x 10 size lumber? 4 x 12 Fb=1020 Fv=180 Fcp=625 E=1600000 Sff W1=8.12 Glued Laminated Members (GLB) Glulam Grade 24F.v4(DFiDf) Acceptable Solutions 3 1/8" x 9 1/2" 5 1/2" x 9" 3 1/2" x 9" 6 3/4" x 7 1/2" 5 1/8" x 9" 8 3/4" x 9" List properties for what size glulam? e,a• x 17" Fb=2400 Fv=265 Fcp=650 E=1800000 Fb1=1850 Self Wl=36.4 2.0E Microllam LVL - Illil plv List properties for what 13/4" x 11-7/8" (3) 13/4" x 9-1/2" size LVL? (2) 13/4" x 9-1/2" (4) 13/4" x 7-1/4" (2) 1-314- x 11-Tyr Fb=2600 Fv=285 Fcp=750 E=2000000 Slf W1=7.4 2.0E Microllam LVL List properties for what 13/4" x 11-7/8" size LVL? 3-1/2" x 9-1/2" 7" x 7-1/4" 3-Uz' xn-rye- Fb=2600 Fv=285 Fcp=750 E=2000000 Slf W1=7.4 Final Member s-wand Material Grade Tributary Uniform Live Reduced Live Uniform De. Load, of. Load, plf. - 45.0 Ibttt 75.0 Wit - 75.0 Ib/ft 75.0 Wit 45.0 Ib/ft W, = 75.0 Ib/ft ` ID = 45.0 Ib/ft `Nu = 120.0 Ib/fl 5x And Larger (Timbers) Douglas fir - Larch (North) No. 1 Acceptable Solutions 6x10 List properties I - I I Slf W1=15.51 for what size? 6x 1z Fb=1300 Fv=170 Fcp=625 E=1600000 2.2E Parallam PSL 3-1/2" x 9-1/4" 7" x 9-1/4" 5-1/4" x 9-1/4" Sff Wt= 18.5 List properties for what size? 7•x1t-t/a- Fb=2900 Fv=290 Fcp=750 E=2000000 Web Stiffeners? 11.7/8" TJI/ L65 - 16" TJI / L65 - 16" TJI / L90 11-7/8" TJI 230 14" TJI H90 11-7/8" TJI 360 11-7/8" TJI 560 List properties 1.3/4" x 11.7/8" (3) 13/4" x 9-1/2" for what size? 3-1/2" x (3)1-3l4- xle Fb=2325 Fv=310 Fcp=800 E=1550000 Final Member Results Final Member: 4 x 12, Douglas Fir- Bending Overdesign: 38.4% Material Library choose Frarn mseeeofeeam type Larch (North), No. 1 / No. 2 Shear Overdesign: 415.2% Final Size: axu Deflection Overdesign: 85.1 % Min. Bearing Lengths : = 1.50 in. (Left) . = 1.50 in. (Right) Use Conditions Selected: Bearing / Buckling Overdsgn: N/A Final member OK by: 38.4% Vert Diff (approx): 0.00 ft True Length (approx): Actual Member Size: 3.50" x 11.25" 16.00 ft Controlling criteria is: Bending Reactions Final Member Additional Information Location Live Case Bracino Pedd For Full Strenam: Maximums R, - Le fl R, - Riaht Max. Positive Moment: 4,156 fl-lb 8.00 ft Main Span Live Load: 600 lb 600 lb Lateral bracing Max. Negative Moment: 0 ft-lb 0.00 ft Main Span Max Design Shear: 917 lb 0.00 ft Main Span Dead Load: 439 lb 439 lb Main Span Max. Downward Deflection (Live / Total) 0.166" / 0.288" 8.00' / 8.00, Main/Main Total Load: 1,039 lb 1,039 lb Live Case Causing Max N/A N/A Main Span Max. Upward Deflection (Live / Total) 0.000"/0.0001, 0.001/0.00, Main/Main Minimums R, - Le fl R, - Riahl Cant. Down. Defl. (Live / Total): N/A N/A N/A nc: Live Load: 0 lb 0 lb Cant. U . Defl. Live / Total): N/A N/A N/A h 0.6 or 1.0 Dead: 263 lb 263 lb Req'd El, Not Incl. Self Wt.: 3.318E+08 Actual El: 6.64E+080% Net Reaction 216 lb 216 lb IAII-d Live Case Causing Min N/A N/A Approx. Self Weight: 9.87 plf Approx. Tot. Wt.: 158 lb ent:Min. Calc'd Beari Le ths: = 0.47 in Left = 0.47 in Ri ht fl-Ila Garage Door Header Page 11 of 11 Bradley Engineering, Inc. 811 Yew St. Bellingham, WA 98229 CANS RUCTIONCALC Important: Top and bolkxn trust be laterally supported at support and at Oft max Intervals. Dynamo loading not considered. Corrolant with 2018 IBC. Al designs should be checked by a competent professional. Al users shall corroy with State Engineering Law. Injury and / a death can resuh from improper use of this product. Job Name: Whitney Carport Beam I.D.: Window Header Other Info.: Main Span, L Main Span Max. Allowed Live Defl: L / 360 0.13In Main Span Max. Allowed Total Defl: L / 360 = 0.13 in Cantilever (Overhang) Exists? No Pitch if Sloped: Load Duration 01e; 1,4D Loads From Continuous Member? No r�K etio 0¢P� �eea'tic Load and Span Diagram (root To scale. Pitch, lfany, not shown) 500 400 300 c 200 v 100 0 � 0 -100 0.5 1 1.5 2 2.5 3 3.5 4.5 -200 _ Add Self Wt.? yes O No For Wood and Press Treated? Wet Cord? Temp Cord. Sawn Member Repetitive Use? rvo Glul-amsOnly: Nptgesstrratad ® 100dog F$Ie0 Uniform Loads Over Full Length of Member Allow Live Load Red'n? Roof Loads (not including snow) Roof Snow (only) Deck Loads Floor 2 Loads Floor Loads Wall Dead Load Other'psf load and trib. width Additional'plf Unif. Live Loads. Additional'plf Un'rf. Dead Loads. Roof pitch for U. Red'n Beam type for U. Load Subtotals Red'n Total Adjusted Uniform Loads 0.0:12 Nlprhertxeams Combined Total Uniform Load 4x And Smaller (Lumber) Lumber Material Dcuglasfir-L-In(North) 1 ITimberMaterial o. Lumber Grade NI /No.2 � Timber Grade Acceptable Solutions List properties for what size lumber? 4 x 12 Fb=1020 Fv=180 Fcp=625 E=1600000 Sff W1=8.12 Glued Laminated Members (GLB) Glulam Grade 24F-v4(DF/DF) Acceptable Solutions 2x8 (4)2x4 (2)2x6 3x6 (3)2x4 4x6 3 1/8" x 6" 5 1/2" x 6" 3 1/2" x 6" 6 3/4" x 7 1/2" 5 1/8" x 6" 8 3/4" x 9" List properties for what size glulam. g 1a•• x 11 71r Fb=2400 Fv=265 Fcp=650 E=1800000 Fb1=1850 Self Wl=36.4 2.0E Microllam LVL - Illil plv List properties for what 13/4" x 5-1/2" (3) 13/4" x 5-1/2" size LVL? (2) 13/4" x 5-1/2" (4) 13/4" x 5-1/2" (2) 1-314• x 11-TM Fb=2600 Fv=285 Fcp=750 E=2000000 Slf W1=7.4 2.0E Microllam LVL List pro perties for what 13/4" x 5-1/2" size LVL? 3-1/2" x 5-1/2" 7" x 5-1/2" 3.1/2• -11-71 - Fb=2600 Fv=285 Fcp=750 E=2000000 Slf W1=7.4 Final Member sawn wood Tributary Uniform Live Reduced Live Uniform Dear Load, off. Load, plf. - 162.5 lb/ft 270.8 Wit - 270.8 Ib/ft 270.8 lb/ft 162.5 Ib/ft WL = 270.8 Ib/fl WID = 162.5 Ib/ft `Nu = 433.2 Ib/fl 5x And Larger (Timbers) Douglas fir - Larch (North) N. 1 Acceptable Solutions List properties I - I I Slf W1=15.51 for what size? 6x 1z Fb=1300 Fv=170 Fcp=625 E=1600000 2.2E Parallam PSL 3-1/2" x 9-1/4" 7" x 9-1/4" 5-1/4" x 9-1/4" Sff Wt= 18.5 List properties for what size? 7•x1t-t/4• Fb=2900 Fv=290 Fcp=750 E=2000000 Web 11.7/8" TJI/ L65 9-1/2" TJI 110 Stiffeners? 16" TJI / L65 9-1/2" TJI 210 16" TJI / L90 9-1/2" TJI 230 14" TJI H90 11-7/8" TJI 360 List properties 1.3/4" x 9.1/2" (3) 13/4" x 9-1/2" for what size? 3-1/2" x 9-1/2" (3)1-V4• x 1w Fb=2325 Fv=310 Fcp=800 E=1550000 Final Member Results Final Member: 4 x 6, Douglas Fir- Bending Overdesign: 85.5% Material Library Chome Fmm Nl Bssesol Seem type Larch (North), No. 1 / No. 2 Shear Overdesign: 242.1% Final Size: 4.e Min. Bearing Lengths : = 1.50 in. (Left) . = 1.50 in. (Right) Use Conditions Selected: Vert Diff (approx): 0.00 ft True Length (approx): Actual Member Size: 3.50" x 5.50" 4.00 ft Reactions Maximums R, - Le fl R, - Riaht Live Load: 542 lb 542 lb Dead Load: 335 lb 335 lb Total Load: 876 lb 876 lb Live Case Causing Max N/A N/A Minimums R, - Le fl R, - Riohl Live Load: 0 lb 0 lb 0.6 or 1.0 Dead : 201 lb 201 lb Net Reaction 195 lb 195 lb Live Case Causing Min N/A NIA Max. Positive Max. Neaalive Deflection Overdesign: 310.3% Bearing / Buckling Overdsgn: N/A Final member OK by: 85.5% Controlling criteria is: Bending formation Location Live Case Bracing ReaY 76 ft-lb 2.00 ft Main Span Full so-enam: ft-lb 0.00 ft Main Span #N/A Main Span Max. Downward 0.020" / 0.032" 2.00' / 2.00, Main/Main Deflection (Live / Total) Main Span Max. Upward Deflection 0.000"/0.000" 0.00'/0.00' Main/Main (Live / Total) Cant. Down. Defl. (Live / Total): N/A N/A NIA w/o Md-Bracina: Cant. Up. Defl. Live / Total): N/A N/A N/A Bending Radon: Req'd El, Not Incl. Self Wt, 1.871E+07 Actual El: 7.76E+07 #N/A Approx. Self Weight: 4.82 plf Approx. Tot. Wt.: 19 lb Allowed Moment: Min. Calc'd BearingLengths: = 0.40 in Left = 0.40 in (Right) #N/A Window Header