APPROVED RESUB1 BLD2023-0164+Architectural_Plan+3.15.2023_11.26.10_AM+3422615STRUCTURAL NOTES CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC) AS AMENDED BY THE LOCAL JURISDICTION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS LIVE LOADS: SNOW 25 PSF EARTHQUAKE LOADS. - SITE CLASS D SHORT PERIOD SPECTRAL RESPONSE (SpS) 1.03 ONE SECOND SPECTRAL RESPONSE (SDI) 0.56 OCCUPANCY CATEGORY ll SEISMIC IMPORTANCE FACTOR 00 1.00 SEISMIC DESIGN CATEGORY D BASIC SEISMIC FORCE -RESISTING -SYSTEM WOOD S.W. RESPONSE MODIFICATION FACTOR, (R) 6.5 SEISMIC RESPONSE COEFFICIENT (CS) 0.159 WIND LOADS ULT. BASIC WIND SPEED (3 SECOND GUST) 100 MPH EXPOSURE B KZT 1.00 SPECIAL INSPECTION SPECIAL INSPECTION SHALL BE PERFORMED PER CHAPTER 17 OF THE IBC ONLY WHERE REQUIRED BY THE LOCAL JURISDICTION FOR THE FOLLOWING ITEMS: • SOILS (SECTION/TABLE 1705.6) • CONCRETE (SECTION/TABLE1705.3) • WOOD (SECTION 1705.5) REFER TO IBC SECTION 1705.10 AND 1705.11 FOR ADDITIONAL INSPECTION REQUIREMENTS FOR THE STRUCTURAL COMPONENTS OF THE LATERAL FORCE RESISTING SYSTEM. COORDINATE WITH THE CITY OF BELLEVUE BUILDING INSPECTOR FOR REQUIREMENTS OF SPECIAL INSPECTION OF FIELD INSTALLED POST -INSTALLED CONCRETE EMBEDS PRIOR TO INSTALLATION. ALL INSPECTIONS SHALL BE PERFORMED BY QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE ARCHITECT, ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL INSPECTION REPORTS. IF ANY INSPECTION FAILS TO MEET THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, IT SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE DESIGN TEAM. STRUCTURAL OBSERVATION STRUCTURAL OBSERVATION SHALL BE PERFORMED PER CHAPTER 17 OF THE IBC ONLY WHERE REQUIRED BY THE LOCAL JURISDITION. STRUCTURAL OBSERVATION DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR ANY SPECIAL INSPECTIONS REQUIRED. NOTIFY THE ENGINEER A MINIMUM OF ONE WEEK PRIOR TO THE OBSERVATION. FOUNDATIONS. THE FOLLOWING SOIL DESIGN PARAMETERS HAVE BEEN ASSUMED. IF EXCAVATION SHOWS THAT SOIL CONDITIONS DO NOT MATCH THE LISTED DESIGN VALUES, A GEOTECHNICAL ENGINEER SHALL BE RETAINED TO EVALUATE THE SOIL CONDITIONS. NOTIFY THE ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. REINFORCING STEEL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615 GRADE 60. REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. WELDED WIRE REINFORCING SHALL CONFORM TO ASTM A 185. PROVIDE WELDED WIRE FABRIC IN SHEETS WITH 12" LAPS AT SIDES AND ENDS. REINFORCING STEEL SHALL BE DETAILED TO INCLUDE HOOKS AND BENDS IN ACCORDANCE WITH ACI SP-66 AND ACI 318. DEVELOPMENT LENGTHS AND LAP SPLICES SHALL BE PER THE SCHEDULE. MECHANICAL SPLICING OF REINFORCING BARS, IF REQUIRED, SHALL BE BYAN ICBO APPROVED SYSTEM, AND SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR. ALL SPLICE DEVICES SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS APPROVED BY THE ENGINEER. REFER TO ACI FOR PLACING TOLERANCES AND OTHER REINFORCING STEEL REQUIREMENTS. DEVELOPMENT LENGTH AND LAP SPLICE REINFORCING DEVELOPMENT LENGTHS AND LAP SPLICES SHALL BE AS FOLLOWS. ALL LENGTHS ARE IN INCHES BASED ON GRADE 60 REINFORCING. CONSULT ENGINEER FOR OTHER GRADES OF STEEL. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" OF CONCRETE CAST BELOW THE BAR. f'c = 2500 PSI f'c = 3000 PSI BAR SIZE DEVELOPMENT LENGTH LAP SPLICE DEVELOPMENT LENGTH LAP SPLICE TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS #3 23 18 30 23 22 17 28 22 #4 31 24 41 31 29 22 37 29 #5 39 30 51 39 36 28 47 36 #6 47 36 61 47 43 33 56 43 CONCRETE GENERAL NOTES WALL AND COLUMN VERTICAL BARS SHALL START FROM THE TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 112 THE NORMAL BAR SPACING FROM TOP OF FOOTING AND/OR TOP OF FRAMED SLABS. THERE SHALL BE AN ADDITIONAL HORIZONTAL BAR AT A MAXIMUM OF 3" FROM EVERY TOP OF WALL AND BOTTOM OF FRAMED SLABS. PROVIDE CORNER BARS TO MATCH AND LAP ALL HORIZONTAL REINFORCING ON EACH SIDE OF THE CORNER PER SCHEDULE OR BEND ONE SIDE OF HORIZONTAL AROUND CORNER TO PROVIDE LAP SPLICE. PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO BREAK UP EACH SLAB INTO RECTANGULAR AREAS OF NOT MORE THAN 400 SQUARE FEET. AREAS SHALL BE AS SQUARE AS PRACTICAL AND HAVE NO ACUTE ANGLES. JOINT LOCATIONS SHALL BE APPROVED BY THE ARCHITECT PRIOR TO PLACEMENT. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED BEYOND JOINT UNLESS NOTED OTHERWISE IN PLAN. SEE ARCHITECTURAL DRAWINGS AND MECHANICAL DRAWINGS FOR EXACT SIZE AND LOCATION OF • 1,500 PSF (ALLOWABLE BEARING PRESSURE) OPENINGS IN CONCRETE WALLS, FLOORS, AND ROOF. UNLESS INDICATED OTHERWISE, REINFORCE • 35 PCF + SURCHARGE (ACTIVE LATERAL PRESSURE) AROUND OPENINGS GREATER THAN 12" IN ANY DIRECTION WITH (1) #5 EACH SIDE AND (1) #5 x 4'-0" • 200 PCF (PASSIVE PRESSURE) DIAGONAL AT EACH CORNER. EXTEND BARS 2'-0" BEYOND EDGE OF OPENING. IF 2'-0" IS UNAVAILABLE, • 0.4 (COEFFICIENT OF FRICTION) EXTEND AS FAR AS POSSIBLE AND HOOK. HOOK ALL REINFORCING INTERRUPTED BY OPENINGS. FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR COMPACTED STRUCTURAL FILL AS REQUIRED BY THE GEOTECHNICAL ENGINEER. FOOTINGS SHALL BE PLACED AT A MINIMUM OF THE FROST DEPTH REQUIRED BY THE LOCAL JURISDICTION. FOOTING ELEVATIONS SHOWN IN THE DRAWINGS REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. FINAL FOUNDATION ELEVATIONS ARE SUBJECT TO SITE CONDITIONS AND SHALL BE ESTABLISHED BY THE CONTRACTOR. FOOTINGS SHALL BE CENTERED BENEATH THE STRUCTURE ABOVE, UNLESS DIMENSIONED OTHERWISE. THE CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING EXCAVATION, PILE INSTALLATION, AND ANY OTHER CONSTRUCTION EARTHWORK. NOTIFY THE UNDERGROUND UTILITIES LOCATION SERVICE AT LEAST 1 WEEK PRIOR TO CONSTRUCTION AND INDEPENDENTLY VERIFYALL UTILITIES WHICH MAY BE AFFECTED BY THIS PROJECT. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL DAMAGE DAMAGE TO UNDERGROUND UTILITIES RESULTING FROM THEIR WORK. IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. BACKFILL BEHIND ALL RETAINING WALLS WITH WELL -DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. PROVIDE WATER PROOFING SYSTEM AT EXTERIOR FACE OF ALL FOUNDATION WALLS EXPOSED TO EARTH PER ARCHITECTURAL SPECIFICATIONS. CONCRETE ALL CONCRETE WORK SHALL BE PERFORMED IN ACCORDANCE WITH ACI 301 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE" AND ACI 318, "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE". THE CONCRETE SHALL HAVE UNIT WEIGHT OF APPROXIMA TEL Y 150 PCF CONCRETE STRENGTHS AT 28 DAYS (f'c) AND MIX CRITERIA SHALL BE AS FOLLOWS: • SLAB -ON -GRADE: f'c = 2,500 PSI 0.55 WIC RATIO • FOUNDATION & WALLS: f'c = 2,500 PSI 0.55 WIC RATIO A CONCRETE MIX DESIGN SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL IF REQUIRED IN THE SUBMITTAL SPECIFICATIONS. THE MIX DESIGN SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH ACI REQUIREMENTS. ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE WITH ACI TABLE 4.2.1 FOR MODERATE EXPOSURE CONDITION. MINIMUM CONCRETE COVER ON REINFORCING STEEL SHALL BE AS FOLLOWS: • CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" • CONCRETE EXPOSED TO EARTH AND WEATHER: #6 BARS AND LARGER 2" #5 BARS AND SMALLER 1 112" • CONCRETE NOT EXPOSED TO EARTH OR WEATHER. - SLABS, WALLS, AND JOISTS 314" BEAM/COLUMN TIES AND STIRRUPS 1 112" SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, STRIPS, TEXTURE, AND OTHER FINISH DETAILS AT EXPOSED CONCRETE SURFACES. PROVIDE 314" CHAMFER AT ALL CORNERS UNO. STRUCTURAL STEEL ALL STRUCTURAL STEEL WORK SHALL BE PERFORMED IN ACCORDANCE WITH AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AND AWS D 1.1 "STRUCTURAL WELDING CODE - STEEL ". STEEL SHALL BE FABRICATED AND ERECTED WITHIN THE TOLERANCES DEFINED BYAISC. STRUCTURAL STEEL MATERIALS SHALL BE AS FOLLOWS: • SHAPES SHALL CONFORM TO ASTM A992, Fy = 50 KSI. • PLATES, ANGLES, AND RODS SHALL CONFORM TO ASTM A36, Fy = 36 KSI. • STRUCTURAL TUBING SHALL CONFORM TO ASTM A500 GRADE B, Fy = 46 KSI. • STRUCTURAL PIPE SHALL CONFORM TO ASTM A53 GRADE B, Fy = 35 KSI. • BOLTS SHALL CONFORM TO ASTM A325-N (USE 518"0 MINIMUM UNO) • ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GRADE 36, Fy = 36 KSI. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS IN ACCORDANCE WITH AWS AND WABO REQUIREMENTS. USE 70 KSI LOW HYDROGEN ELECTRODES APPROPRIATE FOR THE MATERIALS BEING WELDED. IF NOT SPECIFIED, MINIMUM WELD SIZE SHALL BE PER AWS D1.1. WELDING OF REINFORCING BARS SHALL NOT BE PERMITTED UNLESS SPECIFICALLY CALLED OUT ON DRAWINGS. ALL STEEL EXPOSED TO WEATHER SHALL BE FABRICATED IN ACCORDANCE WITH ASTM A385 AND HOT DIP GALVANIZED IN ACCORDANCE WITH ASTM A123. FASTENERS AND HARDWARE SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH ASTM A153. ALL DAMAGED GALVANIZED COATINGS SHALL BE REPAIRED IN ACCORDANCE WITH ASTM A780 WITH AN APPLIED COATING THICKNESS DETERMINED BY THE ENGINEER. WOOD FRAMING ALL WOOD FRAMING SHALL BE PERFORMED IN ACCORDANCE WITH IBC CHAPTER 23, ANSI/AWC "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION", AND AITC "TIMBER CONSTRUCTION MANUAL ". SAWN LUMBER SHALL BE IDENTIFIED BY THE GRADE MARK OF AN AGENCY APPROVED BY AN ACCREDITATION BODY COMPLIANT WITH DOC PS 20. ALL GRADES SPECIFIED IN THE STRUCTURAL DRAWINGS ARE MINIMUM STANDARDS AND SHALL BE AS FOLLOWS: • STUDS, PLATES, AND BLOCKING HEM -FIR STUD GRADE • JOISTS DOUG-FIR #2 • 4x OR SMALLER BEAMS AND HEADERS DOUG-FIR #2 • 6x OR LARGER BEAMS AND HEADERS DOUG-FIR #1 • POSTS AND TIMBERS DOUG-FIR #2 WOOD FRAMING SHALL BE KILN -DRIED TO A MAXIMUM MOISTURE CONTENT OF 19%. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY, OR EXPOSED TO EARTH OR WEATHER SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA STANDARD U1 AND M4 FOR THE SPECIES, PRODUCT, PRESERVATIVE, AND END USE REQUIRED. GLUED LAMINATED TIMBER SHALL BE MANUFACTURED AND IDENTIFIED IN CONFORMANCE WITH ANSI/AITC A190.1 AND ASTM D3737. UNLESS OTHERWISE SPECIFIED, ALL GLUED LAMINATED TIMBERS SHALL BE DOUGLAS FIR SPECIES. SINGLE SPAN BEAMS SHALL BE COMBINATION 24F-V4 AND MULTI -SPAN BEAMS OR BEAMS THAT CANTILEVER SHALL BE COMBINATION 24F-V8. ALL EXPOSED GLULAMS SHALL HAVE AN ADDITIONAL TENSION LAMINATION SUBSTITUTED FOR A CORE LAMINATION ON THE TENSION SIDE OF UNBALANCED 24F-V4 BEAMS AND ON BOTH SIDES OF BALANCED 24F-V8 BEAMS. STRUCTURAL WOOD PANEL SHEATHING USED ON WALLS, FLOORS, OR ROOFS SHALL CONFORM TO THEIR SPECIFIC REQUIREMENTS IN DOC PS 1, DOC PS 2, OR ANSI/APA PRP 210. PLYWOOD SHALL BE GRADE C-D WITH EXTERIOR GLUE. REFER TO IBC SECTIONS 2303.1.4, 2304.6, AND 2304.7 FOR ADDITIONAL COMPLIANCE REQUIREMENTS. PRE -MANUFACTURED JOISTS, BEAMS, AND TRUSSES PRE -MANUFACTURED JOISTS, BEAMS, AND TRUSSES SHALL BE SIZED, SPACED, AND DETAILED TO MATCH THE LOADING AND DIMENSIONAL REQUIREMENTS INDICATED ON THE STRUCTURAL DRAWINGS. TRUSSES SHALL COMPLY WITH IBC 2303.4, I -JOISTS SHALL COMPLY WITH IBC 2303.1.2, AND COMPOSITE BEAMS SHALL COMPLY WITH 2303.1.9. THE MANUFACTURER'S DESIGNER IS RESPONSIBLE FOR CODE COMPLIANCE AND SHALL PROVIDE SHOP DRAWING AND CALCULATION SUBMITTALS AS SPECIFIED. ENGINEER AND BUILDING OFFICIAL APPROVAL IS REQUIRED PRIOR TO FABRICATION OF PRE -MANUFACTURED COMPONENTS. REFER TO THE DESIGN LOADS FOR BASIC STRUCTURAL LOADING REQUIREMENTS. REFER TO THE ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR ADDITIONAL LOADING AND OPENING REQUIREMENTS NOT SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS. DEFLECTIONS SHALL NOT EXCEED L1480 FOR LIVE LOADS OR L1360 FOR TOTAL LOADS UNLESS APPROVED IN WRITING BY THE ENGINEER. ALL TRUSSES WITH A DEPTH EQUAL TO OR GREATER THAN 24" SHALL BE DESIGNED FOR A BOTTOM CHORD LIVE LOAD OF 10PSF, NOT APPLIED CONCURRENT WITH THE TOP CHORD LIVE LOAD. PROVIDE TEMPORARY BRACING UNTIL SHEATHING AND PERMANENT BRACING IS INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. THE MANUFACTURER SHALL PROVIDE ALL SPECIALTY ITEMS REQUIRED FOR A COMPLETE INSTALLATION OF THE SYSTEM (INCLUDING BUT NOT LIMITED TO FULL DEPTH BRIDGING, BLOCKING, WEB STIFFENERS, AND PRODUCT SPECIFIC CONNECTORS. NAILS, SCREWS, BOLTS, AND CONNECTORS REFER TO THE PLANS, NOTES, SCHEDULES, AND DETAILS FOR ALL NAILING REQUIREMENTS. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1. ALL NAILS SHALL CONFORM TO THE STANDARD DIMENSIONS OF COMMON NAILS AS DEFINED BY THE NDS AND SHALL MEET THE FOLLOWING MINIMUM GUIDELINES: • 8d=0.131"0x2112" • 10d = 0.148"0 X 3" • 16d = 0.162"0 x 3 112" 10d BOX NAILS (0.128"0 x 3') MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148"0 x 3 1/4'), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THE DRAWINGS. OTHER NAILS MAY BE SUBSTITUTED ONLY WITH THE ENGINEER'S APPROVAL PRIOR TO START OF CONSTRUCTION. ALL LAG SCREWS AND BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE STANDARD CUT WASHERS UNDER THE HEADS AND NUTS OF ALL LAG SCREWS AND BOLTS BEARING ON WOOD. LEAD HOLES FOR BOLTS SHALL BE PROVIDED AND SHALL BE A MINIMUM OF 1/32" AND A MAXIMUM OF 1116" LARGER THAN THE BOLT DIAMETER. LEAD HOLES FOR LAG SCREW SHANKAND THREADS SHALL BE PER NDS 12.1.4.2. ALL WOOD CONNECTORS SHALL BE SIMPSON STRONG -TIE OR ENGINEER APPROVED EQUIVALENT. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS USING THEIR SPECIFIED NUMBER AND SIZE OF FASTENERS. IF STRAPS CONNECT TWO MEMBERS, PLACE 112 OF THE NAILS, SCREWS, OR BOLTS INTO EACH MEMBER. ALL NAILS, SCREWS, BOLTS, AND METAL CONNECTORS IN CONTACT WITH PRESSURE TREATED OR FIRE RETARDANT TREATED WOOD SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH ASTM A153. WOOD FRAMING GENERAL NOTES SILL PLATES BEARING ON CONCRETE FOUNDATIONS SHALL BE PRESSURE TREATED AND SHALL ATTACH TO THE CONCRETE WITH 112"0 ANCHOR BOLTS EMBEDDED 7" MINIMUM. PLACE ANCHORS AT 4'-0" OC MAXIMUM FOR SHEAR WALLS AND AT 6'-0" OC FOR BEARING AND PARTITION WALLS. USE A MINIMUM OF (2) ANCHOR BOLTS PER SILL PLATE AND PLACE ONE WITHIN 12" OF EACH END OF EACH PIECE. REFER TO THE SHEAR WALL SCHEDULE FOR MORE STRINGENT ANCHORAGE SIZE AND SPACING REQUIREMENTS. CONTRACTOR SHALL INSTALL 3 GAUGE PLATE WASHERS BENEATH EACH NUT AT EACH ANCHOR BOLT IN A SHEAR WALL THAT EXTEND TO WITHIN 112" OF SHEATHED EDGE. ALL SHEAR AND/OR BEARING WALLS SHALL BE FRAMED WITH 2x STUDS 0 16" OC. REFER TO PLAN NOTES FOR TYPICAL HEADER SIZES NOT SPECIFICALLY CALLED OUT. ALL HEADERS SHALL BE SUPPORTED BYA MINIMUM OF (1) CRIPPLE AND (1) FULL HEIGHT STUD. COLUMNS BELOW FLUSH FRAMED MULTIPLE JOIST BEAMS SHALL BE EQUAL IN WIDTH TO THE BEAM. ALL COLUMNS NOT CALLED OUT SHALL BE (2) STUDS. BEAMS SHALL HAVE FULL BEARING ON COLUMNS AND POSITIVE CONNECTION SHALL BE PROVIDED. PROVIDE SOLID BLOCKING BETWEEN JOISTS AND RAFTERS AT ALL SUPPORTS, AT 8'-0" OC MAXIMUM SPACING BETWEEN SUPPORTS, AND BENEATH PARTITIONS PERPENDICULAR TO THE DIRECTION OF FRAMING. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN. MINIMUM NAILING REQUIREMENTS SHALL BE PER IBC TABLE 2304.10.1. THE USE OF NAIL GUNS IS APPROVED IF NAILING INTO THE DIAPHRAGMS IS FLUSH WITH FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1116" ARE NOT ACCEPTABLE. NOTCHES AND HOLES IN WALL STUDS ARE ALLOWED WITHIN THE PARAMETERS OF IBC SECTIONS 2308.5.9 AND 2308.5.10. NOTCHES AND HOLES IN JOISTS AND RAFTERS ARE ALLOWED WITHIN THE PARAMETERS OF IBC SECTIONS 2308.4.2 AND 2308.7.4. VERTICAL SHRINKAGE WILL OCCUR AND ACCUMULATE AT EACH LEVEL FROM THE WOOD DRYING OVER TIME. THIS IS ESTIMATED TO BE APPROXIMATELY 0.15" PER FLOOR AND ASSUMES THE WOOD HAS AN INITIAL MOISTURE CONTENT OF 19% OR LESS. ADDITIONAL SHRINKAGE WILL OCCUR IF THE MOISTURE CONTENT IS HIGHER. THE CONTRACTOR SHALL ALLOW FOR THIS MOVEMENT IN THEIR INSTALLATION OF ALL VERTICAL ASSEMBLIES INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, MECHANICAL, AND ARCHITECTURAL SYSTEMS. GENERAL NOTES STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. REFER TO THE ARCHITECTURAL DRAWINGS FOR ELEVATIONS, SLOPES, NON -BEARING WALLS, STAIRS, CURBS, DRAINS, RAILINGS, WATERPROOFING, FINISHES, ETC. REFER TO THE ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPES, VENTS, DUCTS, AND OTHER OPENINGS NOT SPECIFICALLY INDICATED ON THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL VERIFYALL DIMENSIONS AND FIELD CONDITIONS FOR COMPATIBILITY WITH THE PLANS, SPECIFICATIONS, AND REFERENCED STANDARDS BEFORE PROCEEDING WITH ANY WORK. THE MOST STRINGENT REQUIREMENT SHALL GOVERN ANY CONFLICT UNLESS APPROVED IN WRITING OTHERWISE. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN TEAM LEGEND DEFINITION DIRECTION OF FRAMING SYMBOL DEFINITION SYMBOL NATIVE SOIL GRANULAR FILL STRUCTURAL STEEL - - - - - EXTENT OF FRAMING COLUMNS Ink COLUMN BEARING ON BEAM P RATED SHEATHING BEAM CONTINUOUS OVER SUPPORT G� SHEAR WALL (SEE SCHEDULE) SWX CONCRETE WALL COLUMN MARK (SEE SCHEDULE) BEARING STUD WALL FOOTING MARK (SEE SCHEDULE) FX NON -BEARING STUD WALL BEARING STUD SHEAR WALL HOLDOWN MARK (SEE SCHEDULE) HANGER MARK (SEE SCHEDULE) X O NON -BEARING STUD SHEAR WALL FLAG NOTE (SEE PLAN NOTES) CMU WALL STEEL MOMENT FRAME CONN. (A) AB ALT ARCH (B) BD BLKG BM BOT BRNG BTWN CJP CLR CMU COL CONC CONN CONT COORD DBL DET DIA DIM DIR EA ELEV ES EX EXP FLR FDN FTG FS GC ABBREVIATIONS ABOVE GLB ANCHOR BOLT HORIZ ALTERNATE KP ARCHITECT KSI BELOW L BAR DIAMETER MECH BLOCKING MF BEAM MTL BOTTOM NS BEARING OC BETWEEN OPP COMPLETE JOINT PENETRATION PL CLEAR PLCS CONCRETE MASONRY UNIT PSI COLUMN PSF CONCRETE PIT CONNECTION PT CONTINUOUS REINF COORDINATE REQ'D DOUBLE SCHED DETAIL SIM DIAMETER SOG DIMENSION STD DIRECTION STIFF EACH STL ELEVATION SYMM EACH SIDE SW EXISTING TOC EXPANSION TOS FLOOR TOW FOUNDATION TYP FOOTING UNO FAR SIDE VERT GENE BEFORE PROCEEDING. ALL WORK SUBJECT CONTRACTOR SHALL BE RESPONSIBLE FOR STRENGTH AND STABILITY OF ANY PARTL Y COMPLETED TO FIELD STRUCTURE. CONTRACTOR IS SOLELY RESPONSIBLE FOR JOB SITE SAFETY AND SHALL PROVIDE INSPECTION FOR TEMPORARY SHORING AND SUPPORT AS REQUIRED UNTIL THE STRUCTURE HAS BEEN COMPLETED. CODE COMPLIANCE CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE DESIGN TEAM FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES ON SHOP DRAWINGS DO NOT SATISFY THIS REQUIREMENT. REVIEW OF ALTERNATE SYSTEMS MAY BE AN ADDITIONAL SERVICE BY THE ENGINEER. APPROVED PLANS MUST BE DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OFA SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF ON JOB SITE CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE DESIGN TEAM I � Vseparate plumbing permit is required for this ■ ■permit. Please obtain a plumbing permit from Ithe City of Edmonds. ■ OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES GLUE -LAMINATED BEAM HORIZONTAL KING POST KIPS PER SQUARE INCH ANGLE MECHANICAL MOMENT FRAME METAL NEAR SIDE ON CENTER OPPOSITE PLATE PLACES POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT POST TENSIONED PRESSURE TREATED REINFORCING REQUIRED SCHEDULE SIMILAR SLAB ON GRADE STANDARD STIFFENER STEEL SYMMETRICAL SHEARWALL TOP OF CONCRETE TOP OF STEEL TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE VERTICAL Building Department Work Address Owner ------ REMODEL ----------------------------- 8914 205TH PL SW HAARD --------------------------- Approved Date Building Official -------------------------------- 3/28/2023 Duw" s -#L W. 71( ofAmic Permit Number BLD2023-0164--------------- REVISIONS Building Department Z a W W Z W o me a) c • $• I.. j a� Q) 3 3 3 LQ OO � CID U Q Q C) L N O CID W N RESUE Mar 15 2021� CITY OF EDMONDS (� DEVELOPMENT SERVICI W DEPARTMENT O Q CL A • 8 �F WAS$ __1 4G� off,` i sti SIGNAL 03/ 13/ 23 REV. DATE DESCRIPTION 0 02107123 PERMIT SUBMITTAL 1 03113123 PERMIT SUBMITTAL PROJECT NO.: 23002.01 DESIGNED BY JMD DRAWN BY: JMD CHECKED BY: CAB SHEET TITLE: STRUCTURAL NOTES SHEET NO.: S REV1 REV2 REV3 REV4 REVS S1.1 ,w 51 _Ii �- - - AC I r � IL r � N "C s r - f F, (10 I w •e.M . 00 ooeT _iI I � � 1 � � �. ,�, .� ...� _ '�. � „- ~ i�t�1 �� �+� I�. __� �.�•. �e �_-.... _..r . _._. _ I - --- •---rill _... ._ It -- I l - - r ....,.. .. _..� �t - 1' 1, I � „r" ` y , _ _ 41 DC 0000 �.b �'I� O �� i0 •ae� _ LAI if' CA - - - - - - - - - - - - - t— _I- jj.. I _ 7_ _ - I • , -I __. — ...�. ROOF FRAMING PLAN 1 SCALE: 3/16" = V-0" EXISTING STUD FRAMING PER PLAN. SHEATHING & NAILING, PER SW SCHEDULE SILL PLATE NAILING PER SW SCHED PANEL EDGE NAILING PER SW SCHED TYP 0a TOP & BOT PL EXISTING FINISHED GRADE PROVIDE ANCHOR BOLT W/ SIZE AND SPACING PER STRUCTURAL NOTES, PLANS, OR SW SCHED EXIST 2x T&G EXIST STEM WALL & FOOTING PER PLAN EXISTING STUD FRAMING PER PLAN. SHEATHING & NAILING, PER SW SCHEDULE SILL PLATE NAILING PER SW SCHED PANEL EDGE NAILING PER SW SCHED TYP 0 TOP & BOT PL EXISTING FINISHED GRADE a PROVIDE ANCHOR BOLT W/ SIZE AND SPACING PER STRUCTURAL NOTES, PLANS, OR SW SCHED EXIST 2x T&G I EXIST STEM WALL & FOOTING PER PLAN 1. S 1 HAH UH 1 IUN - 0 HOLDOWN SCHEDULE CHORD ANCHOR CAPACITY MARK TYPE SIZE STUD NAILS OR BOLTS BOLT (LB) (NOTE 3) (NOTE 2) 1 HDU2 (2) 2x (6) SDS 114"x 2 112" 518"0 2,215 NOTES: 1. REFER TO THE LATEST SIMPSON STRONG -TIE CATALOG FOR ADDITIONAL INSTALLATION REQUIREMENTS. 2. POST INSTALLED HOLDOWN ANCHOR BOLTS SHALL EXTEND 15" MIN INTO STEM AND USE SIMPSON SET-XP EPDXY. 3. AT ALL HOLDOWN CHORDS, PROVIDE PANEL EDGE NAILING PER SHEAR WALL SCHED. SHEAR WALL SCHEDULE MIN FRAMING NAILING RIM JOIST SILL PLATE SILL PLATE FOUNDATION SHEAR TYPE APA-RATED AT ADJOINING AT PANEL OR BLOCK NAILING TO ANCHOR BOLT TO SILL PLATE CAPACITY SHEATHING PANEL EDGES EDGES CONN TO RIM/BLKG SLAB OR SIZE (PLF) TOP PLATE BELOW FOUNDATION SW6 15132" 2x STUD 0.131 "O x 2 1/2" LTP4 OR A35 0.131 "O x 3 114" 112"0 AB 0 3'-10" OC OR 2x 242 ONE SIDE AND BLKG @ 6" OC Ca 26" OC 06.5" OC URFP Co 5'-9" OC NOTES: 1. REFER TO THE SHEAR WALL DETAIL IN THE TYPICAL WOOD FRAMING DETAILS. 2. THE VALUES IN THIS TABLE ARE BASED ON HF GRADE STUDS AND HF GRADE PLATES & RIM/BLOCKING. 3. NAILS AT ADJOINING PANEL EDGES SHALL BE STAGGERED EACH SIDE OF THE COMMON JOINT. 4. INTERMEDIATE FRAMING TO BE WITH 2x MINIMUM MEMBERS. FIELD NAILING 12" OC MAXIMUM. 5. AT ALL SILL PLATE ANCHOR BOLTS IN 2x6 WALLS, INSTALL 3 GA x 3" x 4 112" PLATE WASHERS WITH THE EDGE OF PLATE WASHER WITHIN 112" OF SHEATHED EDGE. FOR 2x4 STUD WALLS, INSTALL 3 GA. x 3" x 3" PLATE WASHERS. 6. PROVIDE A 7" MINIMUM EMBEDMENT FOR AB INTO FOUNDATION OR STEM WALL FOR NEW CONSTRUCTION. IF POST -INSTALLED PROVIDE 6" MINIMUM EMBEDMENT WITH SIMPSON SET-XP EPDXY OR APPROVED EQUIVALENT. 7. 7116" SHEATHING MAY BE USED IN PLACE OF 15132" SHEATHING PROVIDED ALL STUDS ARE SPACED 16" OC OR PANELS ARE APPLIED WITH LONG DIMENSION ACROSS STUDS. FOUNDATION PLAN NOTES: 1. PLACE ALL REINFORCING STEEL ANCHOR BOLTS AND HOLDOWNS PER THE STRUCTURAL NOTES PLANS, AND THE FOUNDATION DETAILS ON THE S3 SHEETS. REFER TO THE FRAMING PLANS FOR LOCATION OF SHEAR WALLS. 2. THE CONTRACTOR SHALL VERIFYALL DIMENSIONS, WALL LOCATIONS, UTILITY PLACEMENT, AND CONCRETE ROUGH OPENINGS WITH THE ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION AND NOTIFY ALL PARTIES OF ANY DISCREPANCIES. ROOF FRAMING PLAN NOTES: 1. REFER TO THE STRUCTURAL NOTES AND TO THE TYPICAL WOOD FRAMING DETAILS FOR FRAMING REQUIREMENTS NOT SPECIFICALLY SHOWN ON THE ROOF FRAMING PLAN OR IN THESE PLAN NOTES. 2. ROOF SHEATHING SHALL BE 112" MINIMUM THICKNESS WITH A 32116 SPAN RATING. ATTACH TO FRAMING BELOW WITH 8d NAILS SPACED AT 6" OC AT ALL DIAPHRAGM BOUNDARIES, PANEL EDGES, SHEAR WALLS, AND COLLECTOR ELEMENTS INDICATED ON PLANS. NAILING AT INTERMEDIATE FRAMING SHALL BE 8d NAILS SPACED AT 12" OC. REFER TO TYPICAL FRAMING DETAILS FOR SHEATHING LAYOUT. ROOF SHEATHING IS UNBLOCKED LINO ON PLAN. 3. HEADERS PER PLAN SUPPORTED BY (1) JACK STUD AND (1) KING STUD EA END. ALL JACK & KING STUDS SHALL MATCH WIDTH OF WALL FRAMING. 4. WALL STUD FRAMING SHALL BE AS FOLLOWS: • 2x4 HF STUD Ca 16" OC FOR EXTERIOR WALLS AND INTERIOR 6" BEARING WALLS. • 2x4 HF STUD 9 12" OC FOR EXTERIOR WALLS GREATER THAN 12' IN HEIGHT • 2x4 HF STUD Ca 16" OC FOR INTERIOR 4" BEARING WALLS. • 2x4 OR 2x6 HF STUDS Ca 16" OC FOR INTERIOR NON -BEARING WALLS REFER TO ARCHITECTURAL DRAWINGS FOR DETERMINATION OF WALL TYPE. ALL SILL AND TOP PLATES SHALL BE HF STUD GRADE. 5. ALL COLUMNS, TRIMMER STUDS, AND BEARING WALLS SHALL BE CONTINUED DOWN TO THE FOUNDATION UNLESS SUPPORTED BYA BEAM BELOW. SOLID BLOCKING SHALL BE PROVIDED WITHIN JOIST SPACES AT THESE LOCATIONS. 6. MULTIPLE PLY BEAMS SHALL BE FASTENED TOGETHER WITH (2) ROWS OF 10d cap 12" OC. PROVIDE 2" MINIMUM EDGE DISTANCE TOP & BOTTOM AND ALTERNATE NAILING ON EACH FACE OF BEAM. 7. PROVIDE CS16 STRAP AT LOCATIONS WHERE COLUMN OR BEAM CUTS DOUBLE TOP PLATE. EXTEND STRAP 12" BEYOND THE CUT EACH DIRECTION WITH (10) 10d EA SIDE. )WN, STUDS, & HERS PER SCHED 2x T& G Y BEND STRAP TO SIDE OF STEM WALL DRAGE PER )WN SCHED STEM WALL & NG PER PLAN 11. HUU UN I IUN -DOWN, STUDS, & 3TENERS PER SCHED ST 2x T&G D & EPDXY PER DOWN SCHED ST STEM WALL & )TING PER PLAN Z a 1--1 cc UJ W C7 Z W o m c I.. j Q) A 3 LQ Q � � Q Q L Q N O 0 W RESUE Mar 15 202" CITY OF EDMONDS () DEVELOPMENT SERVICI LU DEPARTMENT 7 0 Q A • 8 �F WAS$ off,` i sti SIONAL 03/ I�/ 23 REV. DATE DESCRIPTION 0 02107123 PERMIT SUBMITTAL 10 03113123 PERMIT SUBMITTAL PROJECT NO.: 23002.01 DESIGNED BY JMD DRAWN BY: JMD CHECKED BY: CAB SHEET TITLE: FRAMING PLAN, SCHEDULES, & FOUNDATION DETAILS S BEARING FOUNDATION AT CRAWLSPACE SCALE: 1 " = 1 '-0" NON -BEARING FOUNDATION AT CRAWLSPACE SCALE: 1 " = 1 '-0" POST -INSTALLED HOLDOWN DETAILS SCALE: 1 " = 1 '-0" SHEET NO.: S2.1 --------�---- I.I I•I II II II II II II I STAGGER NAILS ON EA SIDE OF PANEL JOINT HEADER WITH CRIPPLE STUDS PER PLAN I WHERE REQUIRED ON III I I SHEAR WALL SCHED I I I I I I I I I I (WHERE APPLICABLE) I IIII I•I I I I I I II II I. IIII I ,� I I•I I•I IJ- II II I�� I I I I II II II I I• I,•� I { r I FULL -HEIGHT HOLDOWN I IIII I• I I I I I I I I I I I CHORD PER SCHEDULE. I • I I I I, PROVIDE PANEL EDGE I j•I I I I I I j .I NAILING. IIII IIII IIII I I I I II II II II I• I I .I I I PT SILL PLATE W/ANCHOR IIII IIII I•I II II I II II j' I .I I BOLTS PER SHEAR WALL IIII I I I I I .I SCHEDULE. PROVIDE IIII I I•I I.I I• I I SIMPSON BP PL WASHERS I I I I I I I I •I WITHIN 112" OF SHEATHING. I j I I j• PROVIDE PANEL EDGE I I I I I I NAILING INTO SILL PL. II I CONCRETE STEM OR FTG II I • I I I • I I I I I AB SIZE AND SPACING PER PLAN AND SHEAR WALL SCHEDULE, TYP NOTES: 1. REFER TO STRUCTURAL NOTES FOR ADDITIONAL INFORMATION. TYPICAL SHEAR WALL DETAIL SCALE:3/4"= 1'-0" LENGTH OF NOTCH SHALL SQ S' NOT EXCEED 113RD THE O JOIST DEPTH u_ O PRE -DRILL HOLE AT CORNERS OF NOTCHES. DO NOT OVERCUT NOTCH AT END OF JOISTS SHALL NOT EXCEED 114 THE JOIST DEPTH. DO NOT NOTCH WHERE PRACTICABLE. W C) OR HOLE 0 114 OF STUD WIDTH MAX z MAX HOLE O SHALL NOT T EXCEED 40% THE STUD DEPTH (I.E. 2 114" FOR 2x6, 04 1 114" FOR 2x4). MINIMIZE 518" MIN CLR HOLE DIAMETER WHERE TO EDGE POSSIBLE. ------------------------------------ ------Fl-------Fl-------n------------r�� II II II II III II II II II III I I I I I I I I I I• I II II II II III II II II II III I'I I'I I'I I.I I I•I II II II II III I II II II jl I�.I I FRAMING AT ADJOINING PANEL EDGES PER I • I • I SHEAR WALL SCHED I II I I II II II II III II II II II I I II II II I III I• I I I.I I.I I.60 II I'I II II II I•I I I I,I I,I II I'I II II II II II II II II II II II II II II II II II II I•I I I I,I I,I II I'I II II II II II II II II II II II II II II II II II II I•I I I I,I I,I II I'I II II II II II II II II II II II II II II II II II II I•I I I I,I I,I II I'I II II II-n-------n------- 1I I I I I I I II II II II II II II II II I I —III- II II �/ RIM BOARD OR BLOCKING \/1 MAX HOLE Q SHALL NOT EXCEED 113 THE JOIST DEPTH (I.E. 3" FOR 2x10, 3.75" FOR 2x12). MINIMIZE HOLE DIAMETER WHERE POSSIBLE. ~O °C co U Ct5 z� BOO N 2x JOISTS PER PLAN OR SCHEDULE. REFER TO MFR RECOMMENDATIONS FOR I -JOIST HOLES AND NOTCHES. NOTE: 1. NOTCHES ARE NOT PERMITTED IN THE MIDDLE 113 OF THE JOIST SPAN. 2. NOTCHES ARE NOT PERMITTED ON THE BOTTOM (TENSION FACE) OF JOISTS WHERE THE WIDTH IS 4x OR GREATER. ALLOWABLE HOLES & NOTCHES SCALE:1"= 1'-0" EXISTING FULL DEPTH 2x BLKG SILL PLATE NAILING PER SW SCHED PANEL EDGE NAILING PER SW SCHED TYP AT DBL TOP PLATE EXIST SHEATHED STUD WALL W/ NAILING PER PLAN & SW SCHED SECTION SCALE: 1"= 1'-0" PANEL EDGE NAILING PER SHEAR WALL SCHEDULE. PROVIDE EDGE NAILING C� HOLDOWN CHORDS SHEATHING PER SHEAR WALL SCHEDULE W/ FIELD NAILING C� 12" OC HOLDOWN CHORD PER SCHEDULE. REFER TO TYPICAL BUILT-UP COLUMN DETAIL ADDITIONAL END STUD IF REQUIRED TO PROVIDE COUNTERSINK FOR HOLDOWN BOLTS NOTES: I. PANELS SHALL BE 4' x 8' EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE THE MINIMUM PANEL DIMENSION SHALL BE24". 2. FASTENER PATTERN SHALL BE PER PLAN AND NOTES. MINIMUM SPACING 1,1 6" O.C. AT PANEL EDGES AND 12" O.C. AT INTERMEDIATE FRAMING, LINO. FRAMING AND SPACING PER PLAN (SHEATHING NOT SHOWN FOR CLARITYAT FRAMING) CONT. PANEL EDGES. PROVIDE 2x OR 3x BLKG TIGHT TO FRAMING WHEN SPECIFIED. 4' x 8' SHEATHING PANEL, TYP. STAGGER PANELS 4' PERP. TO FRAMING TYPICAL FLOOR/ ROOF SHEATHING DETAIL HOLDOWN ANCHOR PER L / SCALE: NTS SCHEDULE SIMPSON CNW COUPLER NUT W/ SIZE TO MATCH HOLDOWN ANCHORAGE PROVIDE SOLID BLKG 0.131 "O x 3" NAILS Ca 12" OC EQUAL TO WIDTH OF 2 114" END STAGGERED FACE NAILING TYPICAL HOLDOWN CHORD ABOVE DISTANCE, TYP FULL LENGTH OF DBL TOP PLATE TOP CHORD 3" OC SPLICE SPACING BOTTOM (2) ROWS OF (6) 0.131 "0 x 3" NAILS CHORD -a 3" OC EA SIDE OF SPLICE SPLICE EXIST ROOF AND CEILING FRAMING UNCHANGED 2x4 BLKG W/ SILL PLATE NAILING OR FRAMING CLIP PER SW SCHED CONC STEM PROVIDE CONT. TOP PLATES WALL & FTG , WHERE LENGTH IS 12' OR LESS 6'-0" MIN BETWEEN SPLICES. SPLICES OCCUR AT 4 OF VERT STUDS TYPICAL TOP PLATE SPLICE DETAIL SCALE: 1"= 1'-0" ADJACENT NAILS IN A ROW ARE TO BE DRIVEN FROM OPPOSITE SIDES, TYP (3) STUDS MAX TO BE USED FOR BUILT-UP COLUMNS UNO ON PLANS 8" OC MAX SPACING BETWEEN ADJACENT NAILS IN A ROW STAGGER NAILS EA SIDE OF STUD WITH 1 112" EDGE DISTANCE. PROVIDE 0.148" x 3" NAILS FOR (2) STUDS & 0.207" x 4 112" NAILS FOR (3) STUDS. PROVIDE (1) ROW OF STAGGERED NAILING FOR 2x4 STUDS. PROVIDE (2) ROWS FOR 2x6 STUDS. TYPICAL BUILT-UP STUD COLUMN DETAIL SCALE: 1"= 1'-0" DBL TOP PLATE PER TYP DETAIL SIMPSON A35 AT EXT WALLS WITH SPANS GREATER THAN 6' (6) 0.131 "Q x 3" NAILS EA END TYPICAL WALL STUDS � I I ��IBEAMIHDR PER PLAN PER PLAN OR NOTES I I--N I AND NOTES TYP BUILT-UP STUD NAILING (1) FULL HT STUD UNO ON PLANS JACK STUDS PER PLAN, OR COL/HOLDOWN SCHEDULES NOTES, OR COL SCHED TYPICAL HEADER DETAIL SCALE: 1 " = 1'-0" Z o 0 r 1�1 W N �. W Z W o c a� 3 uj uj Q � O � � U Q Q L Q N O cc lz:t I11 W N RESUE Mar 15 2021� U Lu CITY OF EDMONDS DEVELOPMENT SERVICI DEPARTMENT O Q �4 A. WA o - 785 s1�vAL W 13/ 2� REV. DATE DESCRIPTION 0 02107123 PERMIT SUBMITTAL PERMIT SUBMITTAL 1 03113123 PROJECT NO.: 23002.01 DESIGNED BY: JMD DRAWN BY: JMD CHECKED BY: CAB SHEET TITLE: WOOD FRAMING DETAILS S SHEET NO.: S4.1