BLD2023-1011_Manufacturer_Specifications_and_Installation_Instructions_8.10.2023_9.37.58_AM_3718180Product Data Performance Pi�r'on SERIES Carrier's Air Conditioners with non -ozone depleting Purone refrigerant provide a collection of features unmatched by any other family of equipment. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information. INDUSTRY LEADING FEATURES / BENEFITS EFFICIENCY • 13 SEER/11 EER • Microtube Technology'" refrigeration system • Indoor air quality accessories available SOUND • Sound level as low as 70 dBA COMFORT • System supports Thermidistat" Control or standard thermostat RELIABILITY • Non -ozone depleting Puron15 refrigerant • Front -seating service valves • Scroll compressor • Internal pressure -relief valve • Internal thermal overload • Low-pressure switch • High-pressure switch • Filter drier • Balanced refrigeration system for maximum reliability DURABILITY WeatherArmor Ultra- protection package: • Solid, durable sheet metal construction • Steel louver coil guard • Baked -on, complete outer coverage, powder paint APPLICATIONS • Long -line - up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.) • Low ambient (down to-20°F/-28.9°C) with accessory kit MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 N N A A A/N N N N AN AN 2 4 A c B 3 3 6 A 0 Product Product Tier Major SEER Cooling Variations Open Series Family Series Capacity 24 = AC A= RES AC C=Performance B =Puron SEER A = Standard Defined 11 12 13 AN N N 0 3 1 Open Voltage Minor Series e Defined Not D Def 3=208/230-1 0, 1, 2... Pi _ C UL US Use of the AHRI Certified TM Mark indicates a manufacturer's This product has been designed and manufactured to participation in the meet Energy Star® criteria for energy efficiency when matched with appropriate coil components. However, program For verification , proper refrigerant charge and proper air flow are critical of certification for individual to achieve rated capacity and efficiency. Installation of products, go to I S 0 9001 this product should follow all manufacturing refrigerant charging and air flow instructions. Failure to confirm www.ahridirectory.org. QMI-SAI Global proper charge and air flow may reduce energy efficiency and shorten equipment life. STANDARD FEATURES Feature 18 24 30 36 42 48 60 Puron Refrigerant X X X X X X X 13 SEER / 11 EER X X X X X X X Scroll Compressor X X X X X X X Louvered Coil Guard X X X X X X X Field —Installed Filter Drier Front —Seating Service Valves X X X X X X X X X X X X X X Internal Pressure —Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Low —Pressure Switch X X X X X X X High —Pressure Switch X X X X X X X Compressor Sound Blanket X X X X X X X X = Standard 2 PHYSICAL DATA UNIT SIZE SERIES 18-32 24-32 30-32 1 36-32 1 42-30 48-30 60-31 Compressor Type Scroll REFRIGERANT Puron® (R-410A) Control TXV (Puron® Hard Shutoff) Charge lb (kg) 3.15 (1.43) 4.40 (2.00) 5.12 (2.32) 5.32 (2.41) 5.84 (2.65) 8.00 (3.63) 8.44 (3.83) COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 1792 2196 2196 3700 3170 3365 4050 Motor HP 1/12 1/10 1/10 1/4 1/5 1/4 1/4 Motor RPM 1100 1100 1100 1100 825 825 825 COND COIL Face Area (Sq. ft.) 8.40 9.85 11.49 15.09 17.25 21.56 25.15 Fins per In. 20 25 25 25 25 25 25 Rows 1 1 1 1 1 1 1 Circuits 3 5 3 4 4 5 5 VALVE CONNECT. (In. ID) Vapor 3/4 3/4 3/4 7/8 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES (In. OD) Rated Vapor* 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8 Liquid 3/8 *Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. OUTDOOR UNIT CONNECTED TO A FACTORY APPROVED INDOOR UNIT Check piston size shipped with indoor unit to see if it matches required indoor piston size. If it does not match, replace indoor piston with correct piston size in table below: OUTDOOR UNIT SIZE — SERIES FAN COIL PISTON SIZE BY OUTDOOR MODEL 018-32 FB4CNF* 49 024-32 FB4CNF* 55 030-32 FB4CNF* 61 036-32 FB4CNF* 70 042-30 FB4CNF* 76 048-31 FB4CNF* 78 * Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up—to—date ratings information. NOTE: Pistons shipped with outdoor units are only qualified and approved with the above listed fan coils. The piston included with the FFMANP* and FPMAN* fan coils are unique to those products and CANNOT be replaced with the piston shipped with outdoor unit. Refer to the AHRI directory (www.ahridirectory.org) to check if your combination can use a piston or requires an accessory TXV. REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengthst for Cooling Only Systems with Puron® Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths: Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit Size Liquid Line Connection Liquid Line Diam. W/TXV AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit BELOW Indoor Vertical Separation it (m) 0-5 (0-1.5) 6-10 (1.8-3.0) 11-20 (3.4-6.1) 21-30 (6.4-9.1) 31-40 (9.4-12.2) 41-50 (12.5-15.2) 51-60 (15.5-18.3) 61-70 (18.6-21.3) 71-80 (21.6-24.4) 1/4 150 150 125 100 100 75 -- -- -- 18 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 225* 150 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 1/4 75 75 75 50 50 -- -- -- -- 24 3/8 5/16 250* 250* 250* 250* 250* 225* 175 125 100 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 1/4 30 -- -- -- -- -- -- 30 3/8 5/16 175 225* 200 175 125 100 75 -- -- 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 5/16 175 150 150 100 100 100 75 -- -- 36 3/8 3//8 250* 250* 250* 250* 250* 250* 250* 250* 250* 5/16 125 100 100 75 75 50 -- -- -- 42 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* 150 48 3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 - - 60 3/8 3/8 250* 250* 250* 225* 190 150 110 -- Maximum actual length not to exceed 200 It (61 m) t Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = outside acceptable range Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Size Liquid Line Connection Liquid Line Diam. w/TXV AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit ABOVE Indoor Vertical Separation It (m) 25 (7.6) 26-50 (7.9-15.2) 51-75 (15.5-22.9) 76-100 (23.2-30.5) 101-125 (30.8-38.1) 126-150 (38.4-45.7) 151-175 (46.0-53.3) 176-200 (53.6-61.0) 1/4 175 250* 250* 250* 250* 250* 250* 250* 18 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 1/4 100 125 175 200 225* 250* 250* 250* 24 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 1/4 30 -- -- -- -- -- -- -- 30 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 5/16 225* 250* 250* 250* 250* 250* 250* 250* 36 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* 5/16 175 200 250* 250* 250* 250* 250* 250* 42 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* 48 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* 60 1 3/8 1 3/8 1 250* 250* 250* 250* 250* 250* 250* 250* * Maximum actual length not to exceed 200 It (61 m) t Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = outside acceptable range REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft (g/m) 3/8 0.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g) 5/16 0.40 (11.83) 1/4 0.27 (7.98) Units are factory charged for 15 ft (4.6 m) of 3/8" liquid line. The factory charge for 3/8" lineset 9 oz. When using other length or diameter liquid lines, charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft x total length) - (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of line set using existing 1/4" liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft) - (9 oz) = (4.95) oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16" liquid line. What is the charge adjustment? Formula: (.40 oz/ft. x 45ft) - (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70°F to 80°F (21.1°C to 26.7°C), and outdoor temperature must be 70°F to 100°F (21.1°C to 37.8°C). If outside these conditions, adjust charge for long line sets by weigh-in method. LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Air Conditioner systems, the chart below shows when an application is considered Long Line. AC with Puron® Refrigerant Long Line Description tt (m) Beyond these lengths, a TXV is required Total Length I Outdoor Unit Above or Below Indoor Unit TXV required beyond 50 ft. (15.2 m) I TXV required beyond 20 ft. (6.1 m) AC with PuronG Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required) Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 + TXV No accessories needed within al- lowed lengths No accessories needed within allowed lengths 175 (53.3) 5/16 + TXV 120 (36.6) 50 (15.2) vertical or 120 (36.6) total 120 (36.6) 3/8 + TXV 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) Note: See Residential Piping and Long Line Guideline for details VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron refrigerant: Vapor Line Sizing and Cooling Capacity Losses — Puron® Refrigerant 1-Stage Air Conditioner Applications Unit Nominal Size (Btuh) Maximum Liquid Line Diameters (In. OD) Vapor Line Diameters (in. OD) Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) 1-Stag AC with Puron a 26-50 (7.9-15.2) 51-80 (15.5-24.4) 81-100 (24.7-30.5) 101-125 (30.8-38.1) 126-150 (38.4-45.7) 151-175 (46.0-53.3) 176-200 (53.6-61.0) 201-225 (61.3-68.6) 226-250 (68.9-76.2) 1/2 1 2 3 5 6 7 8 9 11 18 3/8 5/8 0 1 1 1 2 2 2 3 3 3/4 0 0 0 0 1 1 1 1 1 5/8 0 1 2 2 3 3 4 5 5 24 3/8 3/4 0 0 1 1 1 1 1 2 2 7/8 0 0 0 0 0 1 1 1 1 5/8 1 2 3 3 4 5 6 7 8 30 3/8 3/4 0 0 1 1 1 2 2 2 3 7/8 0 0 0 0 1 1 1 1 1 5/8 1 2 4 5 6 8 9 10 12 36 3/8 3/4 0 1 1 2 2 3 3 4 4 7/8 0 0 0 1 1 1 1 2 2 3/4 0 1 2 2 3 4 4 5 6 42 3/8 7/8 0 0 1 1 1 2 2 2 3 11/8 0 0 0 0 0 0 0 0 0 3/4 0 1 2 3 4 5 5 6 7 48 3/8 7/8 0 0 1 1 2 2 2 3 3 11/8 0 0 0 0 0 0 0 1 1 3/4 1 2 4 5 6 7 9 10 11 60 3/8 7/8 0 1 2 2 3 4 4 5 5 11/8 0 0 0 1 1 1 1 1 1 Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. ACCESSORIES KIT NUMBER KIT NAME 18-32 24-32 30-32 36-32 42-30 48-30 60-31 KAACH1401AAA CRANKCASE HEATER X X X X KAACH1201AAA CRANKCASE HEATER X X X KSACY0101AAA CYCLE PROTECTOR X X X X X X X KAAFT0101AAA FREEZE THERMOSTAT X X X X X X X KSAHS1501AAA HARD START (CAP / RELAY) X X X X X X X KSALA0301410 LOW AMBIENT KIT X X X X X X X HC40GE228 MOTOR, FAN BALL BEARING X X KSALA0601AAA MOTORMASTER 230V X X X X X X X KAALS0201LLS SOLENOID VALVE X X X X X X X KSASF0201AAA SUPPORT FEET KIT X X X KSASF0101AAA SUPPORT FEET KIT X X X X KAATD0101TDR TIME DELAY RELAY X X X X X X X KSATX0201PUR TXV PURON X X KSATX0301PUR TXV PURON X X X KSATX0401PUR TXV PURON X KSATX0501PUR TXV PURON X KSBTX0201PUR TXV PURON X X KSBTX0301PUR TXV PURON X X X KSBTX0401PUR TXV PURON X X KAAWS0101AAA WINTER START X X X X X X X x = Accessory ACCESSORY THERMOSTATS THERMOSTAT / SUBBASE PKG. DESCRIPTION TP—WEM01 C6r- Thermostat TP—PRH01—A edge— Programmable Relative Humidity Thermostat TP—PAC01 edge— Programmable Thermostat TP—NRH01 edge— Non —Programmable Relative Humidity Thermostat TP—NAC01 edge— Non —Programmable Thermostat TC—WHS01 Wi—Fi® Thermostat TC—PAC01 Programmable Thermostat TC—NAC01 Non —Programmable Thermostat TCSNAC01 Non —Programmable Standard Screen Thermostat THERMOSTAT ACCESSORIES PART NUMBER DESCRIPTION THERMOSTATS USED WITH TP—EXP edge'" EXP® Card Programmable edge" thermostats TSTATCCSEN01—B Outdoor Air Temperature Sensor TP—Pxx, TP—Nxx TSTATXXCNVI0 Thermostat Conversion Kit (4 to 5 wire)-10 pack All Carrier® branded thermostats TX—MBP01 Medium Decorative Backplate TC—Nxx TX—LBP01 Large Decorative Backplate TP—Pxx, TP—Nxx, TC—Pxx ACCESSORY USAGE GUIDELINE REQUIRED FOR LOW-AMBI- REQUIRED FOR LONG REQUIRED FOR ACCESSORY ENT COOLING APPLICATIONS LINE APPLICATIONS* SEA COAST APPLICATIONS (Below 55°F/12.8°C) (Over 80 ft./24.38 m) (Within 2 miles/3.22 km) Ball Bearing Fan Motor Yest No No Compressor Start Assist Capacitor and Relay Yes Yes No Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Hard Shut -Off TXV Yes Yes Yes Liquid Line Solenoid Valve No No No Motor MasterO Control or Yes No No Low -ambient Pressure Switch Support Feet Recommended No Recommended Winter Start Control Yes No No * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 35 ft. (10.67 m) vertical differential, refer to Residential Split -System Longline Application Guideline. t Required for Low -Ambient Controller (full modulation feature) MotorMaster® Control. ACCESSORY DESCRIPTION AND USAGE (LISTED ALPHABETICALLY) 1. Ball -Bearing Fan Motor 6. Low -Ambient Pressure Switch Kit A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when using MotorMaster® 2. Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for single-phase scroll compressors in the following applications: Long line Low -ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in Low -ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 4. Cycle Protector The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling. 5. Evaporator Freeze Thermostat An SPST temperature -actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when Low -ambient kit has been added. A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low -ambient temperatures down to 0°F (-17.8°C)when properly installed. Usage Guideline: A Low -Ambient Pressure Switch must be used when cooling operation is at outdoor temperatures below 55°F (12.8°C) to a minimum of 0°F (-17.8°C). Suggested for all commercial applications. 7. MotorMaster® Low -Ambient Controller A fan -speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20°F (-28.9°C), it maintains condensing temperature at 100°F ±10°F (37.8°C ± 6.5 ° Q. Usage Guideline: A MotorMasterO Low Ambient Controller or Low -Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). Suggested for all commercial applications. ACCESSORY DESCRIPTION AND USAGE (LISTED ALPHABETICALLY) (CONT) 8. Outdoor Air Temperature Sensor 11. Time -Delay Relay Designed for use with Carrier Thermostats listed in this An SPST delay relay which briefly continues operation of indoor publication. This device enables the thermostat to display the blower motor to provide additional cooling after the compressor outdoor temperature. This device also cycles off. is required to enable special thermostat features such as auxiliary NOTE: Most indoor unit controls include this feature. For those heat lock out. that do not, use the guideline below. Usage Guideline: Suggested for all Carrier thermostats listed in this publication. 9. Support Feet Four or five astick-on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 10. Thermostatic Expansion Valve (TXV) A modulating flow -control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shutoff types are available. NOTE: When using a hard shutoff TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Accessory required to meet AHRI rating and system reliability, where indoor not equipped. Hard shutoff TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. Usage Guideline: Accessory required to meet AHRI rating, where indoor not equipped. 12. Winter Start Control This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation. AHRI RATINGS For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Carrier database at: www.MyCarrierRatings.com For performance data at specific application &/or design conditions with various indoor unit combinations, the equipment performance calculator can be accessed at : http://rpmob.wrightsoft.com/ ELECTRICAL DATA UNIT SIZE VOLTAGE, SERIES V/PH OPER VOLTS* COMPR FAN MCA MAX FUSE** or CKT BRK AMPS MAX MIN. LRA RLA FLA 18-32 208/230/1 253 197 47.5 9.0 0.5 11.8 20 24-32 62.9 10.9 0.7 14.3 25 30-32 67.8 12.8 0.6 16.6 25 36-32 75.0 14.7 1.4 19.8 30 42-30 112.0 17.9 1.2 23.6 40 48-30 109.0 19.9 1.2 26.2 40 60-31 134.0 26.4 1.20 34.2 50 * Permissible limits of the voltage range at which the unit will operate satisfactorily. ** Time -Delay fuse. FLA - Full Load Amps LRA - Locked Rotor Amps MCA - Minimum Circuit Amps RLA - Rated Load Amps NOTE: Control circuit is 24-V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2007 requirements of ASHRAE Standards 90.1 A -WEIGHTED SOUND POWER (dBA) UNIT SIZE - VOLTAGE, SERIES STANDARD RATING (dBA) TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment) 125 250 500 1000 2000 4000 8000 18-32 70 50.1 55.6 61.3 67.4 63.2 60.4 52.8 24-32 72 52.9 62.3 65.0 67.8 64.0 61.9 55.3 30-32 74 52.8 62.4 65.0 69.2 68.6 63.0 55.7 36-32 72 58.7 65.1 66.4 65.6 62.6 60.0 52.3 42-30 74 55.0 64.0 68.0 68.5 64.5 60.0 54.0 48-30 74 52.5 62.5 65.5 69.0 63.5 60.5 56.0 60-31 74 54.0 59.0 65.5 67.5 63.5 60.0 55.5 NOTE: Tested in accordance with AHRI Standard 270-2008 (not listed in AHRI). CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE -VOLTAGE, SERIES REQUIRED SUBCOOLING °F (°C) 18-32 15 (8.33) 24-32 13 (7.22) 30-32 14 (7.78) 36-32 10 (5.56) 42-30 10 (5.56) 48-30 17 (9.44) 60-31 11 (6.11) O DIMENSIONS OPERATING SHIPPING SHIPPING SHIPPING UNIT SERIES ELECTRICAL A B C D E IF G H I K WEIGHT WEIGHT LENG TH HEIGHT C ($y,) (sq.) INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM Lbs Kgs Lbs Kgs INCH MM INCH MM 24ACB318A 2 Y N N N 23 118 587.3 25 5/16 642.9 3/4 19.1 4 7116 113.0 18 1/16 459.0 7 13/16 197.9 5/16 7.9 3 76.2 11 1/2 292.1 13 330.2 12 1/2 317.5 117 53.1 130 59.0 25 1/4 641.5 29 3/4 755.8 24ACB324A 2 Y N N N 25 314 654.0 25 5116 642.4 3/4 19.1 4 7/16 113.0 21 114 539.9 9 118 231.3 5/16 7.9 3 76.2 14 355.6 15 381.0 11 112 292.1 127 57.6 150 68.0 27 718 708.2 29 314 755.8 24ACB330A 2 Y N N N 25 314 654.0 2811116 728.7 314 19.1 4 7/16 113.0 21 114 539.9 9 118 231.3 5/16 7.9 3 76.2 13 330.2 13 1/2 342.9 13 330.2 138 62.6 162 73.5 27 718 708.2 33 3/16 843.1 24ACB336A 2 Y N N N 31 3116 792.5 2811116 728.7 718 22.2 6 9/16 166.1 2411116 626.3 9 118 231.3 5116 7.9 3 76.2 15 112 393.7 16 406.4 14 355.6 169 76.7 194 88.0 33 5116 646.6 33 3116 843.1 24ACB342A 0 Y N N N 31 3116 792.5 32 1116 815.1 718 22.2 6 9/16 166.1 2411116 626.3 9 118 231.3 5/16 7.9 3 76.2 15 314 400.1 16 1/4 412.8 13 314 349.3 210 95.3 238 108.0 33 5116 846.6 36 5/8 929.5 24ACB348A 0 Y N N N 31 3/16 792.5 38 718 987.8 718 22.2 6 9/16 166.1 24 11116 626.3 9 1/8 231.3 5/16 7.9 3 76.2 14 114 362.0 17 1/4 438.2 19 114 489.0 236 107.0 264 119.7 33 5116 846.6 43 3/8 1102.2 24ACB360A 1 Y N N N 35 889.0 38 7/8 987.8 7/8 22.2 6 9/16 166.1 28 7/16 722.8 9 1I 231.3 5/16 7.9 3 76.2 20 5l8 523.9 19 3/4 501.7 18 3/8 466.7 261 118.4 295 133.8 37 1/8 943.1 43 3l8 1102.2 NOTES: d d Y=YES 1. ALLOW 24" (609.6) CLEARANCE TO SERVICE SIDE OF UNIT, 48" (1219.2) ABOVE UNIT, 6" (152.4) ON ONE SIDE, 12" (304.8) ON REMAINING SIDE, AND 24" (609.6) BETWEEN UNITS FOR PROPER AIRFLOW. 2. CENTER OF GRAVITY Q� . 3. SERIES DESIGNATION IS THE 13TH POSITION OF THE A so. UNIT MODEL NUMBER. AIR DISCHARGE T / / AIR IN AIR DISCHARGE F � FIELD POWER SUPPLY CONN .. B 7/8"(0 22.2) HOLE WITH AIR IN -AIR IN 1 1/8"(028.6) KNOCKOUT FIELD CONTROL SUPPLY CONN. ¢ T/8"(022.2) HOLE ® E LIOUID3LIINE CONN� K J 3 3/4" 3 1/2" (96.0) (88.9) I H D O CVAPOR LINE CONN. l Y so.� 1 13/i6" 46.71 112" r= X so. (12.7) 3/8"f09.51 TIEDOWN KNOCKOUTS (2) PLACES 2 13/16" ..X.. ..r. 71 AIR IN UNIT SIZE MINIMUM GROUND MOUNTING MINIMUM ROOF -TOP MOUNRNG PAD APPLICATION DIMENSIONS PAD APPLICATION DIMENSIONS 18 23 1/8 587.3 17 7/8 1 454.6 24,30 25 3/4 654.0 20 7/16 518.5 36,42,48 31 3/16 792.s 22 15/16 583.2 NOTE: ALL DIMENSIONS IN INCH (MM) U.S. EXPORT CLASSIFICATION: EAR99 60 35 889.0 26 3/4 679.7 SD5420-4 REV. D CLEARANCES Clearances (various examples) Wall 6" (152.4 mm) 24" 12" 12" (609.6) (304.8) (304.8) Service 12" (304.8) 24" 24" (609.6) (609.6) Service Service 18" 18" 1 18" (457.2) (457.2) (457.2) Note: Numbers in () = mm Wall 24" Service 12" (304.8) 24" (609.6) Service '152.4)I E IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re -circulation of discharge air. A07833 DETAILED COOLING CAPACITIES# EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES ° F (°C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) CFM EWB °F(°C) Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys, KW** Outdoor Section Capacity MBtuh Total Sys. KW** Section Capacity MBtuh Total Sys, KW** Capacity MBtuh Total Sys. KW** Total Sens# Total Son Total With CNPV*2414AL* Sens# Indoor Total Sens$ Total Sens# 72 (22.2) 20.77 10.24 1.24 19.95 9.96 1.39 19.07 9.66 1.56 18.09 9.33 1.76 17.01 8.96 1.98 67 (19.4) 19.01 12.71 1.25 18.21 12.41 1.40 17.37 12.09 1.57 16.44 11.75 1.77 15.41 11.39 1.99 525 63 (17.2)tt 17.69 12.24 1.26 16.91 11.92 1.41 16.09 11.59 1.58 15.20 11.24 1.77 14.20 10.87 1.99 62 (16.7) 17.46 15.15 1.26 16.72 14.80 1.41 15.94 14.49 1.58 15.21 15.08 1.77 14.37 14.37 1.99 57 (13.9) 17.10 17.10 1.26 16.48 16.48 1.41 15.83 15.83 1.58 15.13 15.13 1.77 14.35 14.35 1.99 72 (22.2) 21.08 10.74 1.27 20.25 10.46 1.42 19.34 10.15 1.59 18.33 9.82 1.79 17.21 9.44 2.01 67 (19.4) 19.30 13.54 1.28 18.49 13.23 1.43 17.60 12.93 1.60 16.62 12.61 1.80 15.59 12.26 2.02 600 63 (17.2)tt 17.98 13.01 1.29 17.17 12.69 1.44 16.30 12.38 1.61 15.39 12.06 1.80 14.41 11.65 2.02 62 (16.7) 17.85 16.29 1.29 17.23 15.65 1.43 16.51 16.37 1.60 15.71 15.71 1.80 14.88 14.88 2.02 57 (13.9) 17.75 17.75 1.29 17.10 17.10 1.44 16.42 16.42 1.61 15.68 15.68 1.80 14.86 14.86 2.02 72 (22.2) 21.29 11.21 1.29 20.45 10.93 1.45 19.53 10.62 1.62 18.50 10.28 1.82 17.36 9.89 2.04 67 (19.4) 19.50 14.36 1.31 18.65 14.08 1.46 17.76 13.80 1.63 16.82 13.42 1.83 15.78 13.00 2.05 675 63 (17.2)tt 18.17 13.78 1.32 17.33 13.50 1.47 16.49 13.17 1.64 15.59 12.76 1.83 14.61 12.32 2.05 62 (16.7) 18.39 16.74 1.31 17.64 17.64 1.46 16.93 16.93 1.63 16.16 16.16 1.83 15.30 15.30 2.05 57 (13.9) 18.28 18.28 1.31 17.61 17.61 1.46 16.90 16.90 1.63 16.14 16.14 1.83 15.28 15.28 2.05 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9) 85 (29.4) 1 95 (35) 105 (40.6) 115 (46.1) CFM EWB °FCC) Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys, KW** Outdoor Section Capacity MBtuh Total Sys. KW** Section Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW** Total Sens$ Total Sens$ Total With CNPV*2414AL* Sens$ Indoor Total Sens$ Total Sens$ 72 (22.2) 27.25 13.68 1.65 26.06 13.26 1.83 25.42 13.04 2.09 23.78 12.47 2.31 22.10 11.90 2.56 67 (19.4) 24.87 16.90 1.65 23.80 16.48 1.84 22.68 16.05 2.05 21.79 15.71 2.37 20.31 15.15 2.59 700 63 (17.2)tt 23.14 16.27 1.66 22.14 15.85 1.85 21.09 15.42 2.06 20.07 15.00 2.32 18.78 14.48 2.60 62 (16.7) 22.83 20.07 1.66 21.87 19.64 1.85 20.88 19.17 2.06 20.02 19.86 2.32 18.95 18.95 2.59 57 (13.9) 22.38 22.38 1.66 21.60 21.60 1.85 20.77 20.77 2.06 20.01 20.01 2.36 18.91 18.91 2.59 72 (22.2) 27.61 14.35 1.68 26.41 13.93 1.87 25.79 13.72 2.13 24.06 13.14 2.34 22.56 12.63 2.62 67 (19.4) 25.26 18.00 1.69 24.16 17.58 1.88 23.00 17.15 2.09 22.12 16.82 2.40 20.57 16.24 2.63 800 63 (17.2)tt 23.54 17.31 1.70 22.50 16.88 1.88 21.41 16.44 2.10 20.42 16.03 2.36 19.07 15.49 2.63 62 (16.7) 23.36 21.53 1.70 22.54 20.81 1.88 21.55 21.55 2.10 20.72 20.72 2.36 19.62 19.62 2.63 57 (13.9) 23.27 23.27 1.70 22.42 22.42 1.88 21.55 21.55 2.10 20.76 20.76 2.41 19.59 19.59 2.63 72 (22.2) 27.98 15.02 1.72 26.66 14.57 1.91 26.05 14.37 2.16 24.33 13.79 2.39 22.71 13.26 2.66 67 (19.4) 25.55 19.06 1.73 24.42 18.64 1.92 23.24 18.20 2.13 22.16 17.79 2.39 20.75 17.25 2.66 900 63 (17.2)tt 23.83 18.29 1.74 22.83 17.88 1.92 21.66 17.41 2.13 20.62 16.99 2.40 19.28 16.44 2.67 62 (16.7) 24.00 24.00 1.73 23.11 23.11 1.92 22.19 22.19 2.13 21.34 21.34 2.40 20.14 20.14 2.67 57 (13.9) 23.97 23.97 1.73 23.08 23.08 1.92 22.13 22.13 2.13 21.30 21.30 2.39 20.13 20.13 2.67 See notes on page 15 DETAILED COOLING CAPACITIES# CONTINUED EVAPORATOR AIR i CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9) 85 (29.4) 1 95 (35) 105 (40.6) 115 (46.1) CFM EWB °F(°C) Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys, KW** Outdoor Capacity MBtuh Total Sys. KW** Capacity MBtuh Total $yg, KW** Capacity MBtuh Total Sys. KW** Total Sens# Total Sens$ 24ACB330ABN32 Total Sens# Total Sens$ Total Sens# 72 (22.2) 33.50 16.91 2.08 32.19 16.46 2.29 30.70 15.95 2.54 29.03 15.39 2.82 27.46 14.86 3.17 67 (19.4) 30.64 21.05 2.08 29.42 20.59 2.29 28.01 20.05 2.53 26.45 19.47 2.81 24.75 18.84 3.13 875 63 (17.2)tt 28.61 20.29 2.07 27.42 19.80 2.29 26.06 19.25 2.53 24.61 18.66 2.81 23.01 18.03 3.13 62 (16.7) 28.25 25.13 2.07 27.13 24.61 2.29 25.89 25.89 2.53 24.71 24.71 2.81 23.39 23.39 3.13 57 (13.9) 27.91 27.91 2.07 26.95 26.95 2.28 25.86 25.86 2.53 24.67 24.67 2.81 23.36 23.36 3.13 72 (22.2) 33.97 17.81 2.13 32.58 17.34 2.35 31.07 16.84 2.59 29.34 16.27 2.87 27.74 15.75 3.22 67 (19.4) 31.09 22.51 2.13 29.82 22.03 2.34 28.40 21.50 2.58 26.78 20.90 2.86 25.05 20.28 3.19 1000 63 (17.2)tt 29.06 21.64 2.13 27.84 21.15 2.34 26.45 20.59 2.58 24.94 19.99 2.86 23.30 19.34 3.18 62 (16.7) 28.99 28.99 2.12 28.00 28.00 2.34 26.84 26.83 2.58 25.57 25.57 2.86 24.17 24.17 3.18 57 (13.9) 29.00 29.00 2.12 27.96 27.96 2.34 26.80 26.80 2.58 25.53 25.53 2.86 24.13 24.13 3.18 72 (22.2) 34.31 18.68 2.18 32.86 18.20 2.40 31.31 17.69 2.64 29.56 17.13 2.92 27.93 16.60 3.27 67 (19.4) 31.50 23.94 2.18 30.12 23.42 2.39 28.67 22.89 2.63 27.04 22.28 2.91 25.28 21.64 3.25 1125 63 (17.2)tt 29.40 22.94 2.18 28.16 22.44 2.39 26.73 21.87 2.63 25.20 21.25 2.91 23.53 20.57 3.23 62 (16.7) 29.90 29.90 2.18 28.79 28.79 2.39 27.60 27.60 2.63 26.26 26.26 2.91 24.79 24.79 3.24 57 (13.9) 29.86 29.86 2.18 28.76 28.76 2.39 27.56 27.56 2.63 26.22 26.22 2.91 24.75 24.75 3.24 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) CFM EWB °F(°C) Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW** Outdoor Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW** Total Sens$ Total Sens$ Total Sens$ Total Sens$ Total Sens$ 12 (22.2) 45.00 21.31 2.82 42.27 20.46 2.93 39.43 19.58 3.06 36.45 18.68 3.21 33.29 17.73 3.37 67 (19.4) 39.66 26.49 2.80 37.23 25.64 2.91 34.72 24.76 3.04 32.11 23.84 3.18 29.33 22.84 3.36 1050 63 (17.2)tt 35.73 24.94 2.78 33.45 24.08 2.90 31.18 23.22 3.03 28.80 22.30 3.17 26.25 21.28 3.34 62 (16.7) 36.27 36.27 2.78 34.49 34.49 2.90 32.64 32.64 3.03 30.67 30.67 3.18 28.50 28.50 3.35 57 (13.9) 36.21 36.21 2.78 34.44 34.44 2.90 32.59 32.59 3.03 30.62 30.62 3.18 28.46 28.46 3.35 72 (22.2) 44.13 21.83 3.08 41.23 20.95 3.20 38.29 20.06 3.32 35.19 19.14 3.47 31.92 18.16 3.64 67 (19.4) 38.86 27.67 3.06 36.32 26.77 3.18 33.75 25.84 3.30 31.08 24.84 3.45 28.32 23.68 3.62 1200 63 (17.2)tt 34.85 25.91 3.04 32.54 25.02 3.16 30.20 24.08 3.29 27.79 23.05 3.43 25.60 21.29 3.61 62 (16.7) 36.56 36.56 3.05 34.64 34.64 3.17 32.64 32.64 3.30 30.50 30.50 3.44 28.17 28.17 3.62 57 (13.9) 36.51 36.51 3.05 34.60 34.60 3.17 32.59 32.59 3.30 30.46 30.46 3.44 28.14 28.14 3.62 72 (22.2) 42.95 22.22 3.34 39.98 21.33 3.46 36.93 20.42 3.58 33.75 19.48 3.73 30.38 18.48 3.90 67 (19.4) 37.85 28.64 3.32 35.28 27.68 3.44 32.72 26.65 3.56 30.22 25.21 3.71 27.63 27.62 3.88 1350 63 (17.2)tt 33.87 26.69 3.30 31.51 25.70 3.42 29.29 24.42 3.55 26.98 26.98 3.70 24.61 24.61 3.87 62 (16.7) 36.50 36.50 3.31 34.44 34.44 3.43 32.30 32.30 3.56 30.02 30.02 3.71 27.54 27.54 3.88 57 (13.9) 36.46 36.46 3.31 34.41 34.41 3.43 32.26 32.26 3.56 29.99 29.99 3.71 27.52 27.52 3.88 See notes on page 15 DETAILED COOLING CAPACITIES# CONTINUED EVAPORATOR AIR i CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9) 85 (29.4) 1 95 (35) 105 (40.6) 115 (46.1) CFM EWB °F(°C) Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys, KW** Outdoor Section Capacity MBtuh Total Sys. KW** Section Capacity MBtuh Total Sys, KW** Capacity MBtuh Total Sys. KW** Total Sens# Total Sens$ Total With CAP**4221 Sens# AL* Indoor Total Sens$ Total Sens# 72 (22.2) 48.93 25.83 3.05 46.69 24.96 3.36 44.35 24.08 3.73 41.90 23.16 4.17 39.33 22.20 4.68 67 (19.4) 44.63 31.68 2.97 42.59 30.82 3.28 40.45 29.92 3.64 38.19 28.99 4.07 35.83 28.03 4.57 1225 63 (17.2)tt 41.46 30.51 2.93 39.58 29.65 3.23 37.58 28.76 3.59 35.48 27.82 4.00 33.28 26.86 4.49 62 (16.7) 40.87 37.50 2.92 39.07 36.62 3.22 37.20 35.70 3.58 35.25 34.67 4.00 33.36 33.36 4.50 57 (13.9) 39.83 39.83 2.91 38.36 38.36 3.21 36.79 36.79 3.57 35.10 35.10 4.00 33.31 33.31 4.50 72 (22.2) 49.71 26.98 3.13 47.35 26.09 3.45 44.94 25.19 3.82 42.39 24.26 4.26 39.73 23.29 4.77 67 (19.4) 45.42 33.57 3.06 43.22 32.66 3.36 41.00 31.75 3.73 38.68 30.82 4.16 36.25 29.84 4.65 1400 63 (17.2)tt 42.17 32.25 3.01 40.19 31.36 3.31 38.13 30.46 3.67 35.96 29.52 4.09 33.69 28.53 4.58 62 (16.7) 41.78 40.06 3.00 39.96 39.11 3.31 38.09 38.09 3.67 36.34 36.34 4.10 34.43 34.43 4.60 57 (13.9) 41.35 41.35 3.00 39.77 39.77 3.31 38.10 38.10 3.67 36.29 36.29 4.10 34.39 34.39 4.60 72 (22.2) 50.30 28.09 3.21 47.88 27.19 3.53 45.37 26.27 3.91 42.75 25.32 4.35 40.03 24.34 4.86 67 (19.4) 45.99 35.38 3.14 43.72 34.46 3.44 41.44 33.55 3.81 39.05 32.60 4.24 36.58 31.60 4.74 1575 63 (17.2)tt 42.76 33.94 3.09 40.69 33.04 3.39 38.56 32.12 3.75 36.34 31.16 4.17 34.03 30.15 4.66 62 (16.7) 42.58 42.58 3.08 40.97 40.97 3.40 39.19 39.17 3.76 37.30 37.30 4.19 35.30 35.30 4.70 57 (13.9) 42.60 42.60 3.08 40.92 40.92 3.40 39.15 39.15 3.76 37.26 37.26 4.19 35.26 35.26 4.70 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 775 (46.1) CFM EWB °F(°C) Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW** 0 Outdoor Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW** Total Sens$ Total Sens$ Total Sens$ Total Sens$ Total Sens$ 12 (22.2) 54.80 28.81 3.36 52.36 27.89 3.71 49.81 26.94 4.11 47.12 25.95 4.56 44.29 24.93 5.06 67 (19.4) 49.76 35.37 3.33 47.53 34.45 3.68 45.17 33.48 4.08 42.70 32.48 4.53 40.10 31.44 5.03 1400 63 (17.2)tt 46.11 33.99 3.31 44.03 33.06 3.66 41.83 32.09 4.06 39.51 31.08 4.51 37.07 30.04 5.01 62 (16.7) 45.39 41.86 3.31 43.42 40.91 3.66 41.35 39.87 4.05 39.18 39.18 4.50 37.29 37.29 5.01 57 (13.9) 44.38 44.38 3.30 42.77 42.77 3.65 41.04 41.04 4.05 39.20 39.20 4.50 37.24 37.24 5.01 72 (22.2) 55.95 30.53 3.46 53.38 29.59 3.81 50.68 28.61 4.21 47.88 27.60 4.66 44.93 26.56 5.16 67 (19.4) 50.81 38.12 3.43 48.46 37.17 3.78 46.00 36.19 4.18 43.42 35.17 4.63 40.74 34.11 5.13 1650 63 (17.2)tt 47.13 36.55 3.42 44.92 35.59 3.76 42.62 34.60 4.16 40.21 33.58 4.61 37.69 32.50 5.11 62 (16.7) 46.71 45.46 3.41 44.79 44.79 3.76 42.93 42.93 4.16 40.95 40.95 4.61 38.84 38.84 5.12 57 (13.9) 46.50 46.50 3.41 44.75 44.75 3.76 42.88 42.88 4.16 40.90 40.90 4.61 38.80 38.80 5.12 72 (22.2) 56.45 31.49 3.52 53.81 30.54 3.87 51.07 29.55 4.27 48.20 28.54 4.72 45.19 27.47 5.22 67 (19.4) 51.28 39.68 3.49 48.88 38.73 3.84 46.37 37.73 4.24 43.75 36.70 4.69 41.02 35.61 5.19 1800 63 (17.2)tt 47.58 37.99 3.48 45.32 37.03 3.82 42.98 36.03 4.22 40.53 34.98 4.67 37.96 33.87 5.17 62 (16.7) 47.62 47.62 3.47 45.78 45.78 3.82 43.84 43.84 4.22 41.78 41.78 4.68 39.59 39.59 5.18 57 (13.9) 47.56 47.56 3.47 45.73 45.73 3.82 43.79 43.79 4.22 41.73 41.73 4.68 39.55 39.55 5.18 See notes on page 15 DETAILED COOLING CAPACITIES# CONTINUED EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9) 85 (29.4) 1 95 (35) 105 (40.6) Capacity MBtuh Total Sys. Total Sens KW** 115 (46.1) CFM EWB °F(°C) Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW** Outdoor Capacity MBtuh Total Sys. KW** Capacity MBtuh Total Sys. KW** Total Sens$ Total Son i Total Sens$ Total Sens$ 72 (22.2) 68.36 36.10 4.29 65.33 34.94 4.72 62.14 33.73 5.20 58.75 32.46 5.75 55.15 31.13 6.37 67 (19.4) 62.33 44.29 4.21 59.57 43.11 4.64 56.65 41.89 5.12 53.55 40.62 5.67 50.25 39.28 6.30 1750 63 (17.2)tt 57.90 42.64 4.16 55.34 41.48 4.58 52.62 40.25 5.06 49.73 38.98 5.61 46.65 37.62 6.25 62 (16.7) 57.03 52.36 4.16 54.56 51.17 4.57 51.97 49.89 5.05 49.29 48.49 5.60 46.62 46.62 6.25 57 (13.9) 55.44 55.44 4.13 53.46 53.46 4.56 51.33 51.33 5.05 49.04 49.04 5.60 46.55 46.55 6.24 72 (22.2) 69.50 37.80 4.40 66.35 1 36.63 4.83 63.02 1 35.39 5.31 59.50 34.10 5.86 55.77 32.75 1 6.48 67 (19.4) 63.42 47.04 4.32 60.53 45.85 4.75 57.50 44.61 5.23 54.29 43.31 5.78 50.88 41.95 6.40 2000 63 (17.2)tt 58.95 45.21 4.27 56.28 44.02 4.69 53.46 42.78 5.17 50.46 41.49 5.72 47.29 40.10 6.36 62 (16.7) 58.29 56.06 4.26 55.81 54.75 4.69 53.26 53.26 5.17 50.84 50.84 5.73 48.18 48.18 6.37 57 (13.9) 57.63 57.63 4.26 55.50 55.50 4.68 53.22 53.22 5.17 50.77 50.77 5.72 48.13 48.13 6.37 72 (22.2) 70.34 39.41 4.51 67.07 38.20 4.94 63.64 36.95 5.42 60.02 35.64 5.97 56.18 34.27 6.59 67 (19.4) 64.22 49.65 4.43 61.25 48.45 4.86 58.12 47.19 5.34 54.83 45.87 5.88 51.34 44.46 6.51 2250 63 (17.2)tt 59.74 47.64 4.38 1 56.98 46.44 4.80 54.07 1 45.17 5.28 51.01 43.84 5.83 47.75 42.41 6.46 62 (16.7) 59.46 59.46 4.37 57.24 57.24 4.80 54.82 54.82 5.29 52.23 52.23 5.84 49.44 1 49.44 1 6.48 57 (13.9) 59.43 59.43 4.37 57.17 57.17 4.80 54.76 54.76 5.29 52.15 52.15 5.85 49.39 1 49.39 6.48 * Tested combination. t Total and sensible capacities are net capacities. Blower motor heat has been subtracted. # Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh (245 kW) per 1000 CFM (480 US) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 US) of indoor coil air per degree above 80°F (27°C). # Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. ** System kw is total of indoor and outdoor unit kilowatts. tt At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb. EWB - Entering Wet Bulb NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.i. CONDENSER ONLY RATINGS* SST ° F CC) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 55 (12.78) 65 (18.33) 1 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) TCG 15.90 14.80 13.70 12.80 11.90 10.90 9.90 30 (-111) SDT 69.60 78.90 88.30 97.70 107.10 116.40 125.80 KW 0.85 0.96 1.09 1.22 1.38 1.55 1.75 TCG 17.40 16.30 15.20 14.20 13.20 12.20 11.10 35 (167) SDT 70.70 80.00 89.30 98.70 108.00 117.30 126.60 KW 0.84 0.96 1.09 1.22 1.38 1.56 1.76 TCG 19.10 17.90 16.80 15.70 14.60 13.50 12.30 40 (4 44) SDT 71.80 81.10 90.40 99.70 109.00 118.30 127.50 KW 0.83 0.95 1.08 1.22 1.38 1.56 1.76 TCG 20.80 19.50 18.40 17.30 16.10 14.90 13.60 45 (7.22) SDT 72.90 82.20 91.50 100.80 110.10 119.30 128.40 KW 0.82 0.95 1.08 1.22 1.38 1.56 1.77 TCG 22.60 21.30 20.10 18.90 17.70 16.40 15.00 50 (10.0) SDT 74.10 83.40 92.60 101.90 111.10 120.30 129.40 KW 0.81 0.94 1.07 1.22 1.38 1.56 1.77 TCG 24.40 23.10 21.90 20.60 19.30 18.00 16.50 55 (12.78) SDT 75.40 84.60 93.80 103.10 112.30 121.40 130.40 KW 0.80 0.93 1.06 1.21 1.38 1.56 1.77 TCG 20.90 19.70 18.60 17.50 16.30 15.10 13.80 30 (-1.11) SDT 70.60 79.20 88.70 98.20 107.70 117.90 129.70 KW 1.13 1.26 1.41 1.59 1.80 2.05 2.39 TCG 23.10 21.80 20.60 19.30 18.10 16.80 15.40 35 (167) SDT 71.90 80.40 89.70 99.10 108.60 119.00 127.90 KW 1.13 1.26 1.41 1.59 1.80 2.06 2.32 TCG 25.50 24.10 22.70 21.30 19.90 18.60 17.10 40 (4 44) SDT 73.60 82.00 90.80 100.10 109.60 119.60 128.80 KW 1.13 1.26 1.41 1.59 1.80 2.06 2.32 TCG 27.90 26.30 24.90 23.40 22.00 20.60 18.90 45 (7.22) SDT 73.20 82.40 91.80 101.20 110.70 120.80 129.70 KW 1.11 1.25 1.41 1.59 1.80 2.06 2.32 TCG 30.40 28.80 27.20 25.60 24.00 22.60 20.80 50 (10.0) SDT 74.40 83.70 93.00 102.30 111.70 121.70 130.50 KW 1.10 1.24 1.40 1.59 1.80 2.06 2.32 TCG 33.10 31.30 29.60 27.90 26.20 24.70 22.40 55 (12.78) SDT 75.60 84.80 94.20 103.40 112.80 122.60 130.90 KW 1.09 1.23 1.40 1.58 1.80 2.06 2.30 TCG 25.50 24.20 22.80 21.50 20.00 18.50 16.90 30 SDT 71.50 80.80 89.50 98.90 108.20 117.50 126.70 KW 1.41 1.58 1.75 1.96 2.18 2.45 2.74 TCG 28.20 26.70 25.20 23.70 22.10 20.50 18.70 35 (1.67) SDT 73.60 82.10 90.70 100.00 109.30 118.50 127.70 KW 1.43 1.59 1.76 1.96 2.19 2.46 2.76 TCG 30.90 29.30 27.70 26.00 24.30 22.50 20.60 40 (4.44) SDT 73.80 83.10 92.20 101.20 110.40 119.50 128.80 KW 1.41 1.58 1.76 1.97 2.20 2.46 2.78 TCG 33.70 32.10 30.30 28.60 26.70 24.70 22.60 45 (7.22) SDT 75.10 84.50 93.40 102.50 111.60 120.70 129.90 KW 1.41 1.58 1.76 1.97 2.21 2.47 2.79 TCG 36.90 35.10 33.20 31.20 29.20 27.00 24.70 50 (10.0) SDT 76.70 85.80 94.80 103.90 112.90 121.90 131.00 KW 1.42 1.59 1.77 1.98 2.22 2.48 2.80 TCG 40.30 38.30 36.20 34.00 31.80 29.50 27.40 55 SDT 78.40 87.40 96.30 105.30 114.20 123.10 132.60 (12.78) KW 1.43 1.59 1.78 1.99 2.22 2.50 2.83 See notes on page 18 16 CONDENSER ONLY RATINGS CONTINUED SST CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F CC) 55 (12.78) 1 65 (18.33) 1 75 (23.89) 1 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) TCG 32.60 30.50 28.70 27.00 25.20 23.40 21.50 30 (-111) SDT 73.10 82.60 91.10 100.30 109.70 119.00 128.30 KW 1.61 1.88 2.11 2.36 2.63 2.95 3.32 TCG 36.10 33.90 31.80 29.90 27.90 26.00 23.90 35 (167) SDT 74.30 83.90 92.40 101.60 110.80 120.00 129.20 KW 1.61 1.90 2.13 2.38 2.65 2.96 3.34 TCG 40.10 37.60 35.30 33.10 30.90 28.70 26.40 40 (4 ") SDT 76.00 85.10 93.90 102.90 112.10 121.20 130.30 KW 1.64 1.91 2.16 2.41 2.68 2.99 3.36 TCG 44.50 41.70 39.20 36.70 34.30 31.80 29.30 45 (7.22) SDT 77.80 86.60 95.60 104.40 113.40 122.40 131.40 KW 1.69 1.95 2.19 2.44 2.71 3.02 3.38 TCG 49.40 46.30 43.50 40.70 38.00 35.20 32.40 50 (10.0) SDT 79.70 88.50 97.30 106.10 114.90 123.80 132.70 KW 1.74 2.00 2.24 2.48 2.75 3.06 3.42 TCG 54.80 51.40 48.20 45.10 42.00 39.00 35.80 55 (12.78) SDT 82.20 90.70 99.20 107.90 116.60 125.30 134.00 KW 1.81 2.06 2.30 2.54 2.81 3.11 3.46 TCG 37.60 35.70 33.80 31.70 29.60 27.30 25.00 30 (-1.11) SDT 72.60 81.80 91.10 100.30 109.50 118.70 127.90 KW 1.92 2.15 2.40 2.69 3.02 3.40 3.84 TCG 41.50 39.40 37.30 35.00 32.70 30.30 27.70 35 (1.67) SDT 74.10 83.30 92.40 101.60 110.70 119.80 129.00 KW 1.94 2.17 2.43 2.72 3.05 3.44 3.89 TCG 45.70 43.30 40.90 38.50 36.00 33.40 30.60 40 (4.44) SDT 75.70 84.80 93.80 102.90 112.00 121.00 130.10 KW 1.98 2.21 2.46 2.76 3.09 3.49 3.94 TCG 50.10 47.50 44.90 42.20 39.40 36.60 33.70 45 (7.22) SDT 77.40 86.30 95.30 104.30 113.30 122.20 131.30 KW 2.03 2.25 2.51 2.81 3.15 3.55 4.01 TCG 54.80 51.90 49.00 46.10 43.10 40.00 36.90 50 (10.0) SDT 79.20 88.00 96.90 105.80 114.70 123.60 132.50 KW 2.09 2.32 2.58 2.87 3.22 3.63 4.10 TCG 59.70 56.50 53.30 50.10 46.90 43.60 40.20 55 (12.78) SDT 81.10 89.80 98.50 107.30 116.10 125.00 133.80 KW 2.17 1 2.39 2.66 2.96 1 3.32 3.73 4.21 TCG 41.30 39.40 37.20 35.00 32.70 30.20 27.60 30 SDT 74.10 84.20 92.90 102.10 111.40 120.70 129.90 KW 2.19 2.46 2.74 3.06 3.44 3.86 4.32 TCG 45.50 43.40 41.10 38.60 36.10 33.50 30.70 35 (1.67) SDT 75.60 85.20 94.20 103.40 112.70 121.90 131.00 KW 2.22 2.48 2.76 3.10 3.48 3.90 4.37 TCG 50.10 47.70 45.20 42.50 39.80 37.00 34.00 40 (4.44) SDT 78.10 86.50 96.00 104.90 114.00 123.10 132.20 KW 2.27 2.50 2.81 3.13 3.51 3.94 4.41 TCG 55.10 52.40 49.60 46.70 43.80 40.70 37.60 45 (7.22) SDT 79.00 88.10 97.20 106.30 115.40 124.40 133.50 KW 2.28 2.53 2.83 3.17 3.55 3.98 4.45 TCG 60.40 57.40 54.40 51.20 48.10 44.70 41.40 50 (10.0) SDT 81.00 90.00 98.90 107.90 117.10 125.80 134.80 KW 2.31 2.57 2.86 3.20 3.60 4.02 4.50 TCG 66.20 62.80 59.50 56.10 52.60 49.00 45.40 55 SDT 84.00 91.90 100.70 109.70 118.40 127.30 136.10 (12.78) KW 2.37 2.60 2.90 3.24 3.63 4.06 4.54 See notes on page 18 17 CONDENSER ONLY RATINGS CONTINUED SST ° F CC) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 55 (12.78) 1 65 (18.33) 1 75 (23.89) .0 1 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) TCG 52.10 49.70 47.10 44.30 41.40 38.40 35.20 30 (_111) SDT 75.20 84.80 93.60 102.70 111.90 121.00 130.10 KW 2.70 3.04 3.39 3.79 4.25 4.78 5.40 TCG 57.50 54.80 51.90 48.90 45.70 42.40 39.00 35 (167) SDT 77.00 86.80 95.10 104.20 113.20 122.20 131.30 KW 2.74 3.11 3.44 3.84 4.30 4.83 5.45 TCG 63.20 60.10 57.00 53.70 50.30 46.70 43.00 40 (4 ") SDT 78.70 87.70 96.70 105.60 114.60 123.60 132.50 KW 2.79 3.13 3.49 3.90 4.36 4.89 5.51 TCG 69.30 65.90 62.40 58.80 55.10 51.30 47.30 45 (7.22) SDT 80.60 89.50 98.30 107.20 116.10 124.90 133.70 KW 2.85 3.19 3.56 3.97 4.43 4.96 5.57 TCG 75.80 72.00 68.20 64.30 60.20 56.10 51.80 50 (10.0) SDT 82.60 91.30 100.10 108.80 117.60 126.30 135.10 KW 2.92 3.26 3.63 4.04 4.50 5.03 5.63 TCG 82.80 78.50 74.30 70.00 65.60 61.10 56.40 55 SDT 85.70 93.40 101.90 110.50 119.20 127.80 136.40 (12.78) KW 3.04 3.34 3.71 4.12 4.58 5.11 5.71 * AHRI listing applies only to systems shown in Combination Ratings table. KW - Outdoor Unit Kilowatts Only. SDT - Saturated Temperature Leaving Compressor(' F) SST - Saturated Temperature Entering Compressor (°F/°C) TCG - Gross Cooling Capacity (1000 Btuh) 18 GUIDE SPECIFICATIONS GENERAL System Description Outdoor -mounted, air-cooled, split -system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller -type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210. — Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL-us approval. — Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500-hr salt spray test. — Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 450 psig. — Unit constructed in IS09001 approved facility. Delivery, Storage, and Handling Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations. Warranty (for inclusion by specifying engineer) — U.S. and Canada only. PRODUCTS Equipment Factory assembled, single piece, air-cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puron® (R-410A), and special features required prior to field start-up. Unit Cabinet — Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint. Fans AIR-COOLED, SPLIT -SYSTEM AIR CONDITIONER 24ACB3 1-1/2 TO 5 NOMINAL TONS Condenser fan will be direct -drive propeller type, discharging air upward. Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. Fan blades will be statically and dynamically balanced. Condenser fan openings will be equipped with coated steel wire safety guards. Compressor — Compressor will be hermetically sealed. — Compressor will be mounted on rubber vibration isolators. Condenser Coil — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed. Refrigeration Components — Refrigeration circuit components will include liquid -line shutoff valve with sweat connections, vapor -line shutoff valve with sweat connections, system charge of Puron1b (R-410A) refrigerant, and compressor oil. — Unit will be equipped with filter drier for Puron refrigerant. Operating Characteristics — The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption at full load will not exceed kW. — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at conditions of CFM entering air temperature at the evaporator at °FPC wet bulb and °F/°C dry bulb, and air entering the unit at ° F/° C. — The system will have a SEER of Btuh/watt or greater at DOE conditions. Electrical Requirements — Nominal unit electrical characteristics will be v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Unit electrical power will be single point connection. Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. 19 Copyright 2016 Carrier Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 Edition Date: 12/16 Catalog No. 24ACB3-8PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: 24ACB3-9PD 20