Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2023-1042_Manufacturer_Specifications_and_Installation_Instructions_8.17.2023_7.36.52_PM_3733392
Panasonic' INSTALLATION INSTRUCTIONS Ventilating Fan Model No. FV-0511VFL1 FV-0511 VFL1 K Contents GENERAL SAFETY INFORMATION ----------------- 2-3 DESCRIPTION ---------------------------------------- 4 UNPACKING ------------------------------------------ 4 SUPPLIED ACCESSORIES ---------------------------- 4 DIMENSIONS ----------------------------------------- 5 WIRING DIAGRAM ------------------------------------ 5 FEATURES ----------------------------------------- 5-6 INSTALLATION (RETROFIT) ------------------------ 6-8 INSTALLATION (NEW CONSTRUCTION) ---------- 9-11 MAINTENANCE (CLEANING) ------------------------- 11 PRACTICAL GUIDE TO INSTALLATION --- BACK COVER SPECIFICATIONS ------------------------- BACK COVER PRODUCT SERVICE ---------------------- BACK COVER READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product. Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Please carefully read the "GENERAL SAFETY INFORMATION". Failure to comply with instructions could result in personal injury or property damage. Please explain to users how to operate and maintain the product after installation, and this booklet should be presented to users. Please retain this booklet for future reference. GENERAL SAFETY INFORMATION For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed. AWARNING Denotes a potential hazard that could result in serious injury or death. ACAUTION Denotes a hazard that could result in minor injury. NOTICEDenotes a hazard that could result in property damage. The following symbols are used to classify and describe the type of instructions to be observed. 0 This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the unit safely. This symbol is used to alert users to a specific operating procedure that must not be performed. ® This symbol is used to alert users not to disassemble the equipment. symbol is used to alert users to make sure of grounding when using the equipment ®This with the grounding terminal. AWARNING To reduce the risk of fire, electric shock or injury to persons, observe the following 0 Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. 0 Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. eInstallation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire -rated construction. 0 Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigerating and Air -Conditioning Engineers (ASHRAE) and the local code authorities. eWhen cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. eDucted exhaust fans must always be vented to the outdoors. 0 If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. AThese models are UL listed for tub and shower enclosures. 2 English GENERAL SAFETY INFORMATION CONTINUED GThis product is not to be installed in a ceiling thermally insulated to a value greater than R60. ® Do not disassemble the unit for reconstruction. It may cause fire or electric shock. eIf this product is no longer to be used, it must be removed from the ceiling to prevent it from falling. eThe ceiling joist must be able to withstand a static load of at least five times the weight of the product. Do not install with a method which is not approved in the instructions. Do not use this fan with any solid-state speed control device. Solid state controls may cause harmonic distortion which can cause a humming noise in the motor. ® This product must be properly grounded. A CAUTION Do not install this ventilating fan in a location where the interior room temperature may exceed 104 °F (40 °C). 9 Make sure that the electric service supply voltage is AC 120 V, 60 Hz. 0 Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Administration (OSHA). 8 Always disconnect the power source before working on or near the fan, motor or junction box. eProtect the supply wiring from sharp edges, oil, grease, hot surfaces, chemicals or other objects. Do not kink the su I (cookie area) 0 \ pp y wiring. g Do not install above or = inside this area For general ventilating use only. Do not use to exhaust hazardous ` 1 ' or explosive materials and vapors. � rk5 Aso � G Not for use in cooking area. (Fig. A) Cooking Floor eThe special-purpose or dedicated parts, such as mounting equipment fixtures, must be used if such parts are provided. Fig. A NOTICE eProvide make up air for proper ventilation. Do not install the unit where ducts are configured as shown in below. Adaptor Excessive bending Successive bending Squeezed duct Bend close to duct adaptor Do not connect multiple units in parallel. If two or more units are connected to one switch in parallel, the units may not function. English 3 DESCRIPTION These products are listed by UL under UL file No. E78414. These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is designed to have long operating life, high dynamic response, higher speed ranges and energy savings. The grille covering the fan body is a spring -attached, quick removal type. A damper for preventing air counter flow is provided. The blower uses a high -capacity sirocco fan developed to reduce the noise level. The lighting unit is an energy -saving LED lighting device that uses one 10 W LED lamp and produces almost the same illumination as a standard 40 W incandescent lamp. Night light feature consumes around 0.1 to 0.4 W. FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning this product on and off, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect equipment into outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Warning: This equipment must be installed by qualified person in accordance with the provided installation instructions and all applicable codes and standards. Also, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. DoC Responsible Party: Panasonic Corporation of North America Two Riverfront Plaza, Newark, NJ 07102 Customer Call Center: 1-866-292-7299 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Type IC -Inherently Protected. UNPACKING Unpack and carefully remove the unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. SUPPLIED ACCESSORIES Part name Appearance Quantity Grille1-1 1 Flex-Z FastTM bracket (with 4 <> 1 tapping screws -ST4.2X20) Self -drilling screw � 4 Machine screw 1 (M4X8) Part name Appearance Quantity Warranty sheet 1 Installation instructions 1 Quick —_ Start 1 Guide 3 inch duct reducer 1 (optional part) 4 English DIMENSIONS FV-0511 VFL1 and FV-0511 VFL1 K 13 (330) 8 . 10 3/8 (263) 51/4 (133) WIRING DIAGRAM FV-0511 VFL1 and FV-0511 VFL1 K Unit: inches (mm) No. Part name No. Part name T Blade ® Fan body (Z Grille 90 Damper !� Junction box 10 Flex-Z Fast'm bracket ® Adaptor 0Adjustable color temperature switch (FV-051 1VFL1K only) !� PCB box © Pick -A -Flow switch Q Duct reducer (optional part) Lighting unit *Night Light Fan body Junction box Main control circuit White Neutral > AC 120 V 60 Hz - - --------------------N--utra------------------- -- --- ----------- - Black ---- �--------------Live (Fan) DC Main [� > (Power supply) Motor control Green Power switch (Ground wire) circuit(�� --------------------------------------------------------------------> Power switch Blue 1 Live (N. Light)* LED White Neutral > AC 120 V 60 Hz ---------------------------------- Neutral _----- > Black .......... E�-------------- Live (Light) ---------- (Power supply) Power switch FEATURES Optimum Ventilation Performance: Duct length, elbows and other factors increase static pressure which can hinder the performance of most ventilation fans. These products utilize SmartFlow microchip technology that monitors the static pressure in the system and speeds up or slows down the rpm of the fan depending upon the amount of resistance within the ducts. This feature allows the fan to perform as rated and avoid potential installation issues. Outstanding Energy Savings: These products are built using DC motor technology. The DC motor is 30 % — 70 % more energy efficient than the minimum ENERGY STAR requirements. English 5 FEATURES CONTINUED [For model: FV-0511 VFL1 and FV-0511 VFL1 K] 0 Pick -A -Flow Feature: SON it This product comes with Pick -A -Flow speed options. The Pick -A -Flow switch on the face of the product allows t he option to Q choose 50, 80 or 110 CFM. This product can run continousl y or intermittently, > �� depending upon the needs of the owner. CFM Air volume option (CFM) Factory setting 50 80110 50 80 110 80 CFM [For model : FV-0511VFL1K only] Pick -A -Flow switch Adjustable color temperature Feature: This product comes with an adjustable color temperature swi tch. The adjustable color temperature switch on the LED unit allows the option to choose 3000, 4000, or 5000 K, to match the ro om lighting or the owner preference. Lighting option (K) Factory setting 3000 4000 5000 4000 K The 3000 K LED setting produces a warm white light. The 4000 K LED setting produces a cool white light. The 5000 K LED setting produces a daylight color white ligh t. INSTALLATION (RETROFIT) 000Gt 000a H oaoC� Adjustable color temperature swi IMPORTANT: Damper Adaptor A WARN I N G Remove the tape placed on the damper 0 ° and adaptor before A Disconnect power supply before installing installation. the unit. Tape APlease wear gloves to protect hands during the installation. 1 Install Flex-Z FastTm bracket The Flex-Z FastTm bracket position can be adjusted from 16" to 24" between joists. 0 >Template 4 PAD Drywall 708�d \ \J �s Marker ` \1 I Flex-Z FastTm bracket 1 Template 10� Draw the contour with a marker through marked line ORemove the existing fan and use housing masking template to mark the ceiling opening and cut the ceiling along the marked line. OInsert the Flex-Z Fast TM bracket into the opening and extend. 6 English Unit: inches (mm) 4) Bend down �< a� 4 tabs ® 2 Tapping screws Flex-Z FastTM bracket (ST4.2X20) Bend down 4 tabs and align bracket to the joist. ® Install Flex-Z FastT°° bracket to joist using 2-pr einstalled tapping screws. INSTALLATION (RETROFIT) CONTINUED 2 Tapping screws (ST4.2X20) Fxtotw �n Joist — OExtend bracket to the other joist. © Install bracket to just using 2-pr einstalled tapping screws ror Connect wires 3 Live (Light) Live (Fan) Live (Night o White — Black Earth ® Green ® Blue ❑ Wire connectors Switch 12 Install circular exhaust duct Circular exhaust duct Conduit Flex-Z FastTm bracket 1/ Joist 2 Adaptor 0 0 11 R Junction box cover ORemove screw from junction box cover and secur e conduit or stress relief to junction box knock -out hole. OInstall the circular exhaust duct and secure it with clamps or ties and seal it with mastic or appr oved foil tape. A 3 or 4 inch circular duct is needed to connect to the relevant part of the adaptor. AC 120 V 60 Hz (Power supply) box O Refer to WIRING DIAGRAM. (Page 5) Follow all the local electrical safety codes as well as the National Electrical Code (NEC). Use UL approved wire connectors to connect fan wir es. After connecting wires, replace junction box cover. 4 Install adaptor Conduit A Circular exhaust duct ----------------- 2 Self -drilling scr Drywall K Self -drilling screw OInstall the adaptor to the Flex-Z FastTm bracket by using 2 self- drilling screws. English 7 INSTALLATION (RETROFIT) CONTINUED 5 Plug connector O Machine screw (M4X8) 2 Self -drilling screws (fasten the flange and Flex-Z FastTm bracket through the drywall) OSecure the fan body to Flex-Z FastT"' bracket using 2 self -drilling screws. OPlug connector into receptacle and secure fan body to adaptor by using machine screw (M4X8). Insert fan body Guic Secure fan body 8 Set lighting Drywal Mounting sprir O 5000K �OOOK 3000K Adjustable color temperature switch OSet the adjustable color temperature switch on the lighting option required by the owner. (FV-051 1VFL1 K only).(Refer to explanation under FEATURES). (Page 6) OInsert fan body and slide into adaptor assembly using the guide parts until you hear a click from the hook. [to r 7 Sealing U OOnce fan body is mounted and secure, fill gap between flange and ceiling with caulk or other sealant to prevent air leakage. OAdjust Pick -A -Flow switch. (Refer to explanation under FEATURES). (Page 6) 9 Install grille Drywall OOMounting spring Grille Gloves Receptacle LED lamp wire OConnect the LED lamp wire to fan body. 4) Insert the mounting springs into the slot as shown to mount grille to fan body. A CAUTION] ePlease take care when installing the machine screw (Step 6) to avoid cross threading and to ensure that the screw does not strip or come in contact with the Flex-Z FastTm bracket. 8 English INSTALLATION (NEW CONSTRUCTION) IMPORTANT: Damper Adaptor AWARNING1 Please remove the tape placed on the damper O °� and adaptor before Disconnect power supply before installation. 0 installing the unit. Tape e Please wear gloves to protect hands during the installation. 0 Ensure the junction box cover encloses all the wires and is completely flush before locking in place with the attached screw. �1 Install Flex-Z FastTm bracket The Flex-Z FastTm bracket position can be adjusted fr om 16" to 24" between joists. Bend down 4 tabs O Joist Pj�Or 2 Tapping screws Extend O<' (ST4.2X20) O 2 2 Tapping screws Flex-Z FastTm bracket (ST4.2X20) OBend down 4 tabs and align bracket to the joist. *Extend bracket to the other joist. O Install bracket to joist using 2-pr einstalled tapping ® Install bracket to joist using 2-pr einstalled screws. tapping screws. r2 Install circular exhaust duct F Connecting wires Conduit \01 OJunction box cover Circular exhaust duct 4) 2 Self -drilling screws ORemove screw from junction box cover and secur e conduit or stress relief to junction box knock -out hole OInstall the circular exhaust duct and secure it with clamps or ties and seal it with mastic or appr oved foil tape. A 3 or 4 inch circular duct is needed to connect to the relevant part of the adaptor. *Install the adaptor to Flex-Z FastTm bracket by using 2 self -drilling screws. Live (Night Earth —White —Green ❑ Wire connectors —Black —Blue R Switch 120V60 Hz wer supply) ox (j)Refer to WIRING DIAGRAM. (Page 5). Follow all the local electrical safety codes as well as the National Electrical Code (NEC). Use UL approved wire connectors to connect fan wires. After connecting wires, replace junction box cover. English 9 INSTALLATION (NEW CONSTRUCTION) CONTINUED 4 Insert fan body Assembled view detail Hook O Insert fan body and slide into adaptor assembly using the guide parts until you hear a click from the hook. 5 Secure fai Plug c Machine screw (M4X8) When the flange overlaps the Flex-Z FastTM bracket, secure it using 2 self -drilling screws. 2� Plug connector into receptacle and secure fan body to adaptor using the machine screw (M4X8). 6 Sealing 10M Once fan body is mounted and secure, fill gap between flange and ceiling with caulk or other sealant to prevent air leakage. 20 Adjust Pick -A -Flow switch. (Refer to explanation under FEATURES). (Page 6) 7 Set lighting Dryw Mounting sprir 0) 5=00-K rUmm WWK H Adjustable color temperature switch Set the adjustable color temperature switch on the lighting option required by the owner. (FV-0511 VFL1 K only). (Refer to explanation under FEATURES). (Page 6) 10 English INSTALLATION (NEW CONSTRUCTION) CONTINUED 8 Install grille Drywall �O /Mounting spring Grille Glove Receptacle LED lamp wire MAINTENANCE (CLEANING) AWARNING OConnect the LED lamp wire to fan body. OInsert the mounting springs into the slot as shown to mount grille to fan body . 9 Disconnect power supply before working on unit. A CAUTION 0 Routine maintenance must be done every year. Please wear gloves during the cleaning work. Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan. 1 Remove grille Mounting spring Recepta 1 Grille Gloves �� Slot ORemove grille by pulling down one mounting spring. ODisconnect the wire from the receptacle, then pull down the other mounting spring. Do not immerse motor in water when cleaning. Do not soak resin parts in water over 140 T (60 °C). 2 Maintenance of unit B� Drywall Gloves _Vacuum Ocleaner Gloves rywal I NOTE : The grille should be dry after cleaning. 10 Clean grille. (Don't put into hot water. Use non-abrasive kitchen detergent, wipe dry with clean cloth.) 20 Remove dust and dirt from fan body using a vacuum cleaner. Using a cloth dampened with kitchen deter gent, remove any dirt from fan body. Wipe dry with a clean cloth. Reinstall grille after finishing. English 11 PRACTICAL GUIDE TO INSTALLATION Properly insulate the area around the fan to minimize building heat loss and gain. Loose fill or batt insulation can be placed dir ectly over the fan housing in the attic. Panasonic fans do not create excessive heat, which is a common problem with recessed light fixtures and some competitors' fan/light combinations. Our of ficient, cool - running motors do not cr eate enough ambient heat to be subjected to these limitations. The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, Insulation straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow . SPECIFICATIONS Model No. Air Voltage 9 Frequency Fre q Y Duct diameter Air volume at 0.1 "WG Noise Speed Power Weight direction M (Hz) (inches) (CFM) (sones) (rpm) (W) Ib.(kg) 50 <0.3 768 4.3 FV-0511 VFL1 FV-0511 VFL1 K Exhaust 120 60 4 9.9(4.5) 80 <0.4 867 6.5 110 0.9 1016 11.5 HVI Certified performance based on HVI Procedures 915, 916, and 920. PRODUCT SERVICE Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (U SA). Panasonic Corporation of North America Two Riverfront Plaza, Newark, NJ 07102 www.panasonic.com Printed in Mexico © Panasonic Corporation 2020 P0620-0 511FL1420