M_SVZ-KP30NA_SUZ-KA30NA2_SUBMITTAL-en
Job Name: System Reference: Indoor Unit: SVZ-KP30NA Outdoor Unit: SUZ-KA30NA2 INDOOR UNIT FEATURES • Ducted air handler provides a solution to cool and heat larger zones • Highly efficient completely enclosed EC motor • Selectable external static pressure: 0.30, 0.50 and 0.80 in.WG with 3 fan speeds at each static setting • 1 inch R4.2 fiberglass free insulation reduces condensation and increases efficiency • Positive pressure cabinet with air leakage of less than 2.0% at 1.0 in. w.g. (Tested per ASHRAE Standard 193) • Unique blow through design allows simple coil cleaning when the blower is removed • Multi -position installation: horizontal (left or right), vertical (upflow) • Optional electric heat kit for additional heating capacity • Optional humidifier control, ERV control and auxiliary heat control • Optional downflow kit OUTDOOR UNIT FEATURES • Variable speed INVERTER -driven compressor • Innovative Joint Lap DC Motor leads to high efficiency and reliability • Pulse Amplitude Modulation technology • High-performance grooved piping for increased heat exchange efficiency Date: Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Capacity Btu/h 27,000 Rated Capacity Btu/h 27,000 Cooling 95°F1 Minimum Capacity Btu/h W 13,500 Maximum Power Input 2,160 at Rated Power Input W 2,160 Moisture Removal Pints/h 2.4 Sensible Heat Factor 0.90 Power Factor (208/230V) % 98 Maximum Capacity Btu/h 29,400 Rated Capacity Btu/h 29,400 Cooling at 82°F Minimum Capacity Btu/h 14,600 Maximum Power Input W 1,900 Rated Power Input W 1,900 Maximum Capacity Btu/h 33,000 Rated Capacity Btu/h 30,000 Heating 47°FZ Minimum Capacity Btu/h 12,640 at Maximum Power Input W 2,320 Rated Power Input W 2,060 Power Factor % 98 Heating 17°F3 Maximum Capacity Btu/h Rated Capacity Btu/h 21,400 21,400 at Maximum Power Input W 1,950 Rated Power Input W 1,950 SEER 18.0 EER' 12.5 HSPF (IV) 13.6 Efficiency COP at 47°F2 4.27 COP at 17°F in Maximum Capacity3 3.22 ENERGY STAR® Certified (ENERGY STAR products are third -party certified by an EPA -recognized Certification Body.) Yes Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187-253 Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote Controller V DC 12 Recommended Fuse/Breaker Size A 20 Recommended Wire Size (Indoor - Outdoor) AWG 14 MCA A 4.13 Fan Motor Full Load Amperage A 3.3 Indoor Unit Fan Motor Output W 244 Airflow Rate at Cooling, Dry CFM 875-744-613 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Airfow Rate at Heating, Dry CFM 875-744-613 Sound Pressure Level (Cooling) dB(A) 40-46-32 Sound Pressure Level (Heating) dB(A) 40-46-32 External Static Pressure in.WG 0.30-0.50-0.80 3/4 (19) Drain Pipe Size In. (mm) Heat Exchanger Type Plate fin coil External Finish Color Black Unit Dimensions Package Dimensions W: In. (mm) 21 (533) D: In. (mm) 21-5/8 (549) H: In. (mm) 43-3/4 (1,111) W: In. (mm) 22 (558) D: In. (mm) 28-3/4 (730) H: In. (mm) 48-3/8 (1,228) Unit Weight Lbs. (kg) 119 (54) Package Weight Lbs. (kg) 141 (64) Indoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum)* °F 90F D.B / 71 F W.B // 67F D.B / 57F W.B Temperature Range Heating Intake Air Temp (Maximum / Minimum) °F 80F D.B // 70F D.B MCA A 17 MOCP A 31 Fan Motor Full Load Amperage A 1 Fan Motor Output W 60 2,020 / 1,930 Airflow Rate CFM Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Coolingi dB(A) 55 Sound Pressure Level, Heating2 dB(A) 55 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model SNB220FQGMlT Outdoor Unit Compressor Rated Load Amps A 13.0 Compressor Locked Rotor Amps A 16.0 Compressor Oil Type // Charge oz. FV50S // 15.6 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater Optional Unit Dimensions W: In. (mm) 33-1/16 (840) D: In. (mm) 13 (330) H: In. (mm) 34-5/8 (880) Package Dimensions W: In. (mm) 38-9/16 (980) D: In. (mm) 16-9/16 (420) H: In. (mm) 40 (990) Unit Weight Lbs. (kg) 129 (59) Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Package Weight Lbs. (kg) 148 (67) Cooling Air Temp (Maximum / Minimum)* °F 115 / 14 Outdoor Unit Operating Cooling Thermal Lock -out / Re -start Temperatures** °F 1/5 Temperature Range Heating Air Temp (Maximum / Minimum) °F 75 / 14 10 / 14 Heating Thermal Lock -out / Re -start Temperatures** °F Refrigerant Type R410A Charge Lbs, oz 4,14 Gas Pipe Size O.D. (Flared) In.(mm) 5/8 (12.88) Liquid Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52) Piping Maximum Piping Length Ft. (m) 100 Maximum Height Difference Ft. (m) 100 Maximum Number of Bends 10 Notes AHRI Rated Conditions 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB determined at a fixed compressor speed) 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Wireless Signal Receiver Wireless Signal Receiver Wireless Remote Controller Backlit, Wall -mounted, Wireless Controller ❑ PAR-FA32MA-W ❑ PAR-FA32MA-E ❑ PAR-FL32MA-E ❑ MHK1 Portable Central Controller Wired MA Controller ❑ MCCH1 ❑ PAR-33MAA Simple MA Controller ❑ PAC-YT53CRAU Touch MA Controller ❑ PAR-CT01 MAU-SB Airzone ZBS Wired Blueface Principal Controller White ❑ AZZBSBLUEFACECB Airzone ZBS Wired Think Controller White ❑ AZZBSTHINKCB Airzone ZBS Wireless Think Controller White ❑ AZZBSTHINKRB Airzone ZBS Wired Lite Controller White ❑ AZZBSLITECB Airzone ZBS Wireless Lite Controller White ❑ AZZBSLITERB Wired Remote Sensor ❑ PAC-SE41TS-E Wireless Temperature and Humidity Sensor ❑ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑ MOS1 Flush Mount Remote Temperature Sensor ❑ PAC-USSEN001-FM-1 Wireless Interface ❑ PAC-USWHS002-WF-1 Thermostat Interface ❑ PAC-US444CN-1 kumo station® ❑ PAC-WHS01 HC-E USNAP Interface ❑ PAC-WHS01 UP-E IT Extender ❑ PAC-WHS011E-E BACnet® and MODBUS® Interface ❑ PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter ❑ CN24RELAY-KIT-CM3 Connector cable for remote display ❑ PAC-SA88HA-EP Connector for CN32 (remote on/off) ❑ PAC-SE55RA-E Remote Operation Adapters ❑ PAC-SF40RM-E MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] ❑ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 - 208/230V Drain Pan Level Sensor ❑ DPLS2 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W Separate Power Terminal Block Kit ❑ SPTB1 Electric Heat Lockout Control ❑ ETC-211000-000 Downflow Kit ❑ DFK-M 5kW Electric Heater ❑ EH05-SVZ-M 8kW Electric Heater 10kW Electric Heater ❑ EH08-SVZ-M ❑ EH10-SVZ-M 1 Unable to use with wireless remote controller Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Optional Defrost Heater Hail Guard Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ MAC-886SG-E ❑ MAC-642BH-U1 ❑ HG-A7 ❑ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3" Outdoor Unit Stand —12" High ❑ ULTRILITE1 ❑ QSMS1201 M Outdoor Unit Stand —18" High ❑ QSMS1801 M Outdoor Unit Stand —24" High ❑ QSMS2401M Heavy Duty Wall Mounting Bracket —Coated Steel ❑ QSWB2000M-1 Heavy Duty Wall Mounting Bracket —316 Series Stainless Steel ❑ QSWBSS 10' x 3/8" x 10' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-10 15' x 3/8" x 15' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-15 ❑ MPLS385812T-30 30' x 3/8" x 30' x 5/8" Lineset (Twin -Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-50 65' x 3/8" x 65' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-65 1 00'x 3/8" x 1 00'x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-100 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. o26 Knockout Hole (Indoor / Outdoor unit connection) (Remote controller transmission) Left side view Unit:mm(in.) VIEW e26 Knockout Hole o26 Knockout Hole for electrical heat wiring e4.6 Burring Holes r electric heat installation Secondary Emerge cy drain g) a 19.05(3/4) 3/4"FPT. GOravilrylyy drain)Pipe 19.05(3/4) 3/4"FPT (Horizontal left) Secondary drain pipe (Emergency drain, (Emergency draining) 019.05(3/4) 3/4"F o19.05(3/4) 3/4"FPT (Horizontal Right) Model Nominal Filter Size Duct Connection SVZ-KP12NA 508 x 406.4 x 25.4 (20 x 16 x 1) 376 x 402 (14-13/16 x 15-7/8) SVZ-KP18NA SVZ-KP24NA SVZ-KP30NA 508 x 508 x 25.4 (20 x 20 x 1) 477 x 402 1 (18-13/16 x 15-7/8) SVZ-KP36NA Bottom view i,�ra . n! Primary drain pipe (Gravity drain ' .19.05(3/4) 3j4"FPT Control box -(Remove Blower Panel) Llnit:mnrl Note: Electrical entrance for SVZ located on both left and right side of the cabinet. See right or Left side view for knockout locations. Right side view Model A B C D E F G H J Gas Pipe Liquid pipe SVZ-KP12NA 432 (17) 376 (14-13/16) 281 (11-1/8) 224 (8-7/8) 1,010.8 (39-13/16) 680 (26-13/16) 823 (32-7/16) 735.5 (29) 360 (14-3/16) o 9.52 (3/8) o 6.35 (1/4) SVZ-KP18NA 0 12.7 (1/2) SVZ-KP24NA SVZ-KP30NA 534 1 (21) 477 1 (18-13/16) 382.6 (15-1/8) 266.5 (10-1/2) 1,113.8 (43-7/8) 737 1 (29-1/16) 953.5 1 (37-9/16) 792 (31-3/16) 461 (18-3/16) o 15.88 (5/8) o 9.52 (3/8) SVZ-KP36NA Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 6 REQUIRED SPACE "1 20 in. (500 mm) or more when front U and sides of the unit are clear `� and rear of the unit are clear Service panel Unit: inch Liquid refrigerant pipe joint Refrigerant pipe (flared) o 1/4 (18 kBtu/h) Refrigerant pipe (flared) o 3/8 (24/30/36 kBtu/h) 00 v M CV CM LO CV W Po � Qo N M rn Gas refrigerant pipe joint co M Refrigerant pipe (flared) o 1/2 (18 kBtu/h) Refrigerant pipe (flared) o 5/8 (24/30/36 kBtu/h) 7-11/16 MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com % FORM# SVZ-KP30NA / SUZ-KA30NA2 - 201901 ,s Intertek Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.