APPROVED PLN ENG PLN2021-0034+Civil_Plan+8.10.2022_8.05.40_AM+3042137LOT 2
6)
LOT 1
6)
.16&4+8'9#;241(+.'
*QTK\QPVCN5ECNG
8GTVKECN5ECNG
8+%+0+6;/#2
0
1" = 30'
30 30 60
DATE:APPROVED:DESIGNED:DRAWN:CHECKED:4
-PQYYJCVUDGNQY
%CNNVYQDWUKPGUU
FC[UDGHQTG[QWFKI
SHEET OF
21-0504HERZER SHORT PLATDEVELOPMENTEDMONDSWASHINGTONC1 3
SW 1/4 SW 1/4 SEC.9 ,TWP.26N ,RGE.5E ,W.M.BRETT & CHERI HERZERPLAN*'4<'45*1462.#6
&'8'.12/'062.#0
'&/10&59#5*+0)610
2.0Ä
76+.+6;%10(.+%6016'
%#76+10
241,'%6+0(14/#6+10
5748';016'5
5+6'
x
x
016'5
5JGGV.KUV
5JGGV0WODGT 5JGGV6KVNG
#%%'55#0&76+.+6;
'#5'/'06':*+$+6
016'5
&4;76+.+6;
'#5'/'06':*+$+6
RESUB
Aug 10 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Move public
easement line as
shown in red, to be
future dedication in
lieu of an easement
8/10/2022
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or
occurs during the permitted project.
OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
UTILITIES MAY REQUIRE A SEPERATE PERMIT.
Utility patches shall be combined and full width or half
width overlay will be required depending on the extent
of disturbance. Where utility patches fall entirely within
one travel lane, the overlay shall extend to the
centerline of roadway. Where utility patches extend into
both travel lanes then a full width overlay is required.
SEE ALSO, NOTE 8
INSTALL 6" CLEANOUT WITH A 12"
CAST IRON LAMPHOLE COVER
(WITH PICKHOLE) 1/2" HEXBOLTS
AND A CONCRETE COLLAR.
"Nothing in this permit approval process shall be interpreted as
allowing or permitting the maintenance of any currently existing
illegal, nonconforming or unpermitted building, structure or site
condition which is outside the scope of the permit application,
regardless of whether such building, structure or condition is
shown on the site plan or drawing. Such building, structure or
condition may be the subject of a separate enforcement action."
SEE PARKING
CROSS SECTION
DETAIL ON C3.
C4 TRAFFIC
CONTROL PLAN
APPROVED BY PLANNING
Aug 15 2022
CITY PUBLIC
WORKS DEPT TO
TAP MAIN LINE AND
SET METER.
CONTRACTOR
RESPONSIBLE FOR
ASPHALT
RESTORATION.
PER FIRE MARSHAL, SFR'S WITH DRIVEWAYS
OVER 150 FEET AND/OR OVER A 12% GRADE WILL
REQUIRE FIRE SPRINKLERS. A 13D FLOW
THROUGH TYPE SYSTEM IS RECOMENDED.
DWELLINGS OVER 3000 SF WILL REQUIRE FIRE
SPRINKLERS.
WATER SERVICE LINE
TO BE 1 1/2" IF FIRE
SPRINKLER REQUIRED.
COMPACTION TEST
REPORT FOR THE
SUBGRADE IS REQUIRED
WHERE THE ROAD IS
WIDENED AND WHERE THE
THICKENED EDGE IS
PLACED.
FUTURE
DEDICATION
Dedication
LOT 2
6)
LOT 1
6)
0
1" = 30'
30 30 60
DATE:APPROVED:DESIGNED:DRAWN:CHECKED:4
-PQYYJCVUDGNQY
%CNNVYQDWUKPGUU
FC[UDGHQTG[QWFKI
SHEET OF
21-0504HERZER SHORT PLATTESC & GRADINGEDMONDSWASHINGTONC2 3
SW 1/4 SW 1/4 SEC.9 ,TWP.26N ,RGE.5E ,W.M.BRETT & CHERI HERZERPLAN2.0Ä
76+.+6;%10(.+%6016'
%#76+10
6'5%59222.')'0&016'5
RESUB
Aug 10 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
8/10/2022
GARAGE TO BE
DEMOLISHED
UNDER SEPARATE
BUILDING PERMIT.
DATE:APPROVED:DESIGNED:DRAWN:CHECKED:4
-PQYYJCVUDGNQY
%CNNVYQDWUKPGUU
FC[UDGHQTG[QWFKI
SHEET OF
21-0504HERZER SHORT PLATSTANDARD NOTESEDMONDSWASHINGTONC3 3
SW 1/4 SW 1/4 SEC.9 ,TWP.26N ,RGE.5E ,W.M.BRETT & CHERI HERZER& DETAILS2.0Ä
76+.+6;%10(.+%6016'
%#76+10
%105647%6+10)'0'4#.016'5%105647%6+105'37'0%'016'5
6*566;2+%#.5'%6+10
065
241215'&2#4-+0)
6;2+%#.5'%6+10
065
RESUB
Aug 10 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
8/10/2022
FOR LOT 2
LOT 2
6)
LOT 1
6)
8+%+0+6;/#2
0
1" = 30'
30 30 60
DATE:APPROVED:DESIGNED:DRAWN:CHECKED:4
-PQYYJCVUDGNQY
%CNNVYQDWUKPGUU
FC[UDGHQTG[QWFKI
SHEET OF
21-0504HERZER SHORT PLATTRAFFIC CONTROL PLAN &EDMONDSWASHINGTON1 1
SW 1/4 SW 1/4 SEC.9 ,TWP.26N ,RGE.5E ,W.M.BRETT & CHERI HERZERHAUL ROUTE*'4<'45*1462.#6
64#((+%%10641.2.#0
76+.+6;%10(.+%6016'
%#76+10
5748';016'5
5+6'
64#((+%%10641.016'5
*#7.4176'
RESUB
Aug 10 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
8/10/2022