Loading...
APPROVED PLN ENG PLN2021-0034+Civil_Plan+8.10.2022_8.05.40_AM+3042137LOT 2 “6) LOT 1 “6) .16&4+8'9#;241(+.' *QTK\QPVCN5ECNGž 8GTVKECN5ECNGž 8+%+0+6;/#2 0 1" = 30' 30 30 60 DATE:APPROVED:DESIGNED:DRAWN:CHECKED:4 -PQYYJCVžUDGNQY %CNNVYQDWUKPGUU FC[UDGHQTG[QWFKI SHEET OF 21-0504HERZER SHORT PLATDEVELOPMENTEDMONDSWASHINGTONC1 3 SW 1/4 SW 1/4 SEC.9 ,TWP.26N ,RGE.5E ,W.M.BRETT & CHERI HERZERPLAN*'4<'45*1462.#6 &'8'.12/'062.#0 '&/10&59#5*+0)610 2.0Ä 76+.+6;%10(.+%6016' %#76+10 241,'%6+0(14/#6+10 5748';016'5 5+6' x x 016'5 5JGGV.KUV 5JGGV0WODGT 5JGGV6KVNG #%%'55#0&76+.+6; '#5'/'06':*+$+6 016'5 &4;76+.+6; '#5'/'06':*+$+6 RESUB Aug 10 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Move public easement line as shown in red, to be future dedication in lieu of an easement 8/10/2022 Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. Utility patches shall be combined and full width or half width overlay will be required depending on the extent of disturbance. Where utility patches fall entirely within one travel lane, the overlay shall extend to the centerline of roadway. Where utility patches extend into both travel lanes then a full width overlay is required. SEE ALSO, NOTE 8 INSTALL 6" CLEANOUT WITH A 12" CAST IRON LAMPHOLE COVER (WITH PICKHOLE) 1/2" HEXBOLTS AND A CONCRETE COLLAR. "Nothing in this permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action." SEE PARKING CROSS SECTION DETAIL ON C3. C4 TRAFFIC CONTROL PLAN APPROVED BY PLANNING Aug 15 2022 CITY PUBLIC WORKS DEPT TO TAP MAIN LINE AND SET METER. CONTRACTOR RESPONSIBLE FOR ASPHALT RESTORATION. PER FIRE MARSHAL, SFR'S WITH DRIVEWAYS OVER 150 FEET AND/OR OVER A 12% GRADE WILL REQUIRE FIRE SPRINKLERS. A 13D FLOW THROUGH TYPE SYSTEM IS RECOMENDED. DWELLINGS OVER 3000 SF WILL REQUIRE FIRE SPRINKLERS. WATER SERVICE LINE TO BE 1 1/2" IF FIRE SPRINKLER REQUIRED. COMPACTION TEST REPORT FOR THE SUBGRADE IS REQUIRED WHERE THE ROAD IS WIDENED AND WHERE THE THICKENED EDGE IS PLACED. FUTURE DEDICATION Dedication LOT 2 “6) LOT 1 “6) 0 1" = 30' 30 30 60 DATE:APPROVED:DESIGNED:DRAWN:CHECKED:4 -PQYYJCVžUDGNQY %CNNVYQDWUKPGUU FC[UDGHQTG[QWFKI SHEET OF 21-0504HERZER SHORT PLATTESC & GRADINGEDMONDSWASHINGTONC2 3 SW 1/4 SW 1/4 SEC.9 ,TWP.26N ,RGE.5E ,W.M.BRETT & CHERI HERZERPLAN2.0Ä 76+.+6;%10(.+%6016' %#76+10 6'5%59222.')'0&016'5 RESUB Aug 10 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 8/10/2022 GARAGE TO BE DEMOLISHED UNDER SEPARATE BUILDING PERMIT. DATE:APPROVED:DESIGNED:DRAWN:CHECKED:4 -PQYYJCVžUDGNQY %CNNVYQDWUKPGUU FC[UDGHQTG[QWFKI SHEET OF 21-0504HERZER SHORT PLATSTANDARD NOTESEDMONDSWASHINGTONC3 3 SW 1/4 SW 1/4 SEC.9 ,TWP.26N ,RGE.5E ,W.M.BRETT & CHERI HERZER& DETAILS2.0Ä 76+.+6;%10(.+%6016' %#76+10 %105647%6+10)'0'4#.016'5%105647%6+105'37'0%'016'5 6*566;2+%#.5'%6+10 065 241215'&2#4-+0) 6;2+%#.5'%6+10 065 RESUB Aug 10 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 8/10/2022 FOR LOT 2 LOT 2 “6) LOT 1 “6) 8+%+0+6;/#2 0 1" = 30' 30 30 60 DATE:APPROVED:DESIGNED:DRAWN:CHECKED:4 -PQYYJCVžUDGNQY %CNNVYQDWUKPGUU FC[UDGHQTG[QWFKI SHEET OF 21-0504HERZER SHORT PLATTRAFFIC CONTROL PLAN &EDMONDSWASHINGTON1 1 SW 1/4 SW 1/4 SEC.9 ,TWP.26N ,RGE.5E ,W.M.BRETT & CHERI HERZERHAUL ROUTE*'4<'45*1462.#6 64#((+%%10641.2.#0 76+.+6;%10(.+%6016' %#76+10 5748';016'5 5+6' 64#((+%%10641.016'5 *#7.4176' RESUB Aug 10 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 8/10/2022