BLD2023-1066_Manufacturer_Specifications_and_Installation_Instructions_8.28.2023_9.13.53_AM_3749947AIR CONDITIONERS LE---7 NNOX RESIDENTIAL PROD UC T SPEC/FICA TONS ELITE SERIES LENNOX QUANTUM" COIL MODEL NUMBER IDENTIFICATION EL17XC1 Product Tier ---------------- ' EL =Elite" Series Nominal Efficiency Refrigerant Type -------- , X = R-410A Unit Type ------ LC= Air Condition erer (Condenser) IIIIIIIIIIIIIIIIIM Cooling Stages - - - - L1= Sin le Sta a Com ressor EL17XC1 ELITE° Series R-410A - 60 Hz Bulletin No. 211006 January 2023 Supersedes September 2022 SEER2 up to 17.4 / SEER up to 18.6 1.5to5Tons Cooling Capacity - 16,700 to 59,500 Btuh -036-230A01 � � •-------- Revision Level ------ Ratings Revision Level ------ Voltage 230 = 208/23OV-1 phase-60Hz Nominal Cooling Capacity 018=1.5tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 041/042 = 3.5 tons 047/048 = 4 tons 059/060 = 5 tons J LULU li F- LU LL CG�C�II ���ll G��lllllllllllllllll �llllllllllll IOO�OOOOOOOO, ��lllll!lllll�����lllllllllll co C N O U U U Q O_ O 0) CIO J O 0) a U c > O U C J Cn Cn y J N LCO O O N C L) ,O = Q N s J a) a) U U co N N E c c E am � w O Or 2 2 J fn 2 U) 0 N M L-6 1.6 I� 00 6 :N M O r� M ON (ON r� ON r� T . ca . Q O N U O p . N p coo a) O o '= U)¢ 0 0) O L)i co p + i � p zZ co U cu co U w p can LLB N ++ O 7 ,� -p coo p p VJ > > ~ 0- 2� N cn O Q- O n X X OQ O LU L.L U- C O U)U) H H V APPROVALS AND WARRANTY APPROVALS • AHRI Standard 210/240-2023 certified • AHRI Certified system match -ups and expanded ratings, visit www.LennoxPros.com • ENERGY STAR° Certified • Sound rated to AHRI Standard 270-2008 test conditions • Tested in Lennox' Research Laboratory environmental test room • Rated According to U.S. Department of Energy (DOE) test procedures • Unit and components ETL, NEC and CEC bonded for grounding to meet safety standards for servicing • ETL certified (U.S. and Canada) • ISO 9001 Registered Manufacturing Quality System ViTIA 7 721 k1 r rL • Compressor: • Limited ten years in residential installations • Limited five years in non-residential installations • All other covered components: • Limited five years in residential installations • Limited one year in non-residential installations NOTE - Refer to Lennox° Basic Limited Warranty at www.Lennox.com for additional details. FEATURES APPLICATIONS • 1.5 through 5 ton • Sound levels as low as 72 dBA • Single-phase power supply • Vertical air discharge • Applicable to indoor air handlers or gas furnaces with indoor add -on coils • Shipped completely factory assembled, piped and wired • Factory test operated REFRIGERATION SYSTEM R-410A Refrigerant • Non -chlorine, ozone friendly • Unit is factory pre -charged 0 Outdoor Coil Fan • Direct drive fan • Vertical air discharge • Totally enclosed fan motor • PSC motor (018, 024, 030, 036, 042, 048, 060 models) • ECM motor (041 and 047 models) • Inherently protected • PVC (polyvinyl chloride) coated steel fan guard © Quantum" Coil • Lennox designed and fabricated coil • Enhanced aluminum alloy tube/enhanced fin coil • Superior corrosion resistance • Ripple -edged aluminum fins • Aluminum tube construction • Lanced fins for maximum fin surface exposure • Fin collars grip tubing for maximum contact area • Flared shoulder tubing connections • Factory tested under high pressure • Entire coil is accessible for cleaning ® High Capacity Liquid Line Drier • Factory installed in the liquid line • Drier traps moisture or dirt • 100% molecular -sieve, bead type, bi-flow drier ® High Pressure Switch • Protects the system from high pressure conditions • Automatic reset © Low Pressure Switch • Shuts off unit if suction pressure falls below setting • Provides loss of charge and freeze-up protection • Automatic reset EL17XC1 - 1.5 to 5 Ton Air Conditioner / Page 3 FEATURES REFRIGERATION SYSTEM (continued) Optional Accessories Expansion Valve Kits • Field installed on certain indoor units • See TXV Usage table • Chatleff-style fitting Freezestat • Senses suction line temperature • Cycles compressor off when suction line temperature falls below it's setpoint • Opens at 29°F and closes at 58°F • Installs on or near the discharge line of the evaporator or on the suction line Loss of Charge Switch Kit • Protects compressor from damage from low refrigerant charge conditions • SPST, normally -closed • Automatic reset Refrigerant Line Kits • Refrigerant lines are shipped refrigeration clean • Lines are cleaned, dried, pressurized and sealed at factory • Suction line fully insulated • Lines are stubbed at both ends COMPRESSOR OScroll Compressor • High efficiency with uniform suction flow • Constant discharge flow, high volumetric efficiency and quiet operation • Low gas pulses during compression reduces operational sound levels • Compressor motor is internally protected from excessive current and temperature • Compressor is installed in the unit on resilient rubber mounts for vibration free operation Scroll Compressor Operation • Two involute spiral scrolls matched together generate a series of crescent -shaped gas pockets between them • During compression, one scroll remains stationary while the other scroll orbits around it • Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates • As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced • When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls • During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle • Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency • Compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged Compressor Crankcase Heater (041, 047, 048, 060 models) • Protects against refrigerant migration that can occur during low ambient operation • Factory Installed Compressor Sound Dampening System • Polyethylene compressor • 2 inch thick batt fiberglass insulation • All open edges sealed with one -inch wide hook and loop fastening tape EL17XC1 - 1.5 to 5 Ton Air Conditioner / Page 4 FEATURES COMPRESSOR (continued) Optional Accessories Compressor Crankcase Heater (018, 024, 030, 036, 042 models) • Protects against refrigerant migration that can occur during low ambient operation Compressor Hard Start Kit • Single-phase units are equipped with a PSC compressor motor • This type of motor normally doesn't need a potential relay and start capacitor • For conditions such as low voltage kit may be required to increase the compressor starting torque Compressor Low Ambient Cut -Off Switch • Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35°F CONTROLS Optional Accessories E30 Smart Wi-Fi Thermostat • Wi-Fi enabled, electronic 7-day, universal, multi -stage, programmable, touchscreen thermostat • 3 Heat/2 Cool • Auto -changeover • Controls dehumidification during cooling mode and humidification during heating mode • Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol° control, and equipment maintenance reminders • Easy to read 7 in. color touchscreen (measured diagonally) • LCD display with backlight shows the current and set temperature, time, inside relative humidity, system status (operating mode and schedules) and outside temperature (optional outdoor sensor required) • Smooth Setback Recovery starts system early to achieve setpoint at start of program period • Compressor short -cycle protection (5 minutes) • Up to four separate schedules are available plus Schedule IQTM • One -Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away • Smart AwayTM - Uses geo-fencing technology to determine when the homeowner is within a predetermined distance from the home to operate the system when leaving, away and arriving • Wi-Fi remote monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets • Smart home automation compatible with Apple HomeKitTM, Amazon Alexa°, Google Assistant and IFTTT • Service Dashboard features online real-time monitoring of installed Lennox° smart thermostats • High Definition Color Display with Subbase, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation NOTE - See the Lennox° E30 Smart Wi-Fi Thermostat Product Specifications bulletin for more information Remote Outdoor Temperature Sensor • Used with the Lennox° E30 Smart Wi-Fi Thermostat • When installed outdoors, sensor allows thermostat to display outdoor temperature • Sensor is auto -detected when connected to thermostat NOTE - Sensor is required for the Enhanced Dehumidification Accessory (EDA). Thermostat • Thermostat is not furnished with unit • See Lennox Price Book for selection Indoor Blower Off Delay Relay • Delays the indoor blower -off time during the cooling cycle Low Ambient Kit • Air conditioners can operate down to 457 outdoor air temperature without additional controls • Allows unit to operate properly down to 30°F NOTE - Crankcase heater and freezestat should be installed on compressors equipped with a low ambient kit. NOTE - A compressor lock -out thermostat should be added to terminate compressor operation below recommended operation conditions. Compressor Timed -Off Control • Prevents compressor short -cycling • Allows time for suction and discharge pressure to equalize • Permits compressor start-up in an unloaded condition • Automatic reset with 5 minute delay between compressor shut-off and start-up EL17XC1 - 1.5 to 5 Ton Air Conditioner / Page 5 FEATURES CABINET ©• Heavy -gauge steel construction • Pre -painted cabinet finish • Louvered heavy gauge steel panels surround unit on all four sides • Control box is conveniently located with all controls factory wired • Corner patch plate allows access to compressor components • Drainage holes are provided in base section for moisture removal • High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture PermaGuardTM Unit Base • Durable zinc -coated base section resists rust and corrosion SmartHinge'" Louvered Coil Protection • Steel louvered panels provides complete coil protection • Panels are hinged to allow easy cleaning and servicing of coils • Panels may be completely removed • Interlocking tabs and slots assure tight fit on cabinet ORefrigerant Line Connections, Electrical Inlets and Service Valves • Sweat connection suction and liquid lines • Located on corner of unit cabinet • Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system • Refrigerant line connections and field wiring inlets are located in one central area of the cabinet • See dimension drawing EL17XC1 - 1.5 to 5 Ton Air Conditioner / Page 6 SPECIFICATIONS General Model No. Data Nominal Tonnage EL17XC1-018 EL17XC1-024 EL17XC1-030 EL17XClSO36 EL17XC1-041 1.5 2 2.5 3 3.5 Indoor Unit Expansion Valve (TXV) (If needed) 12J18 112,1118 12,1118 12J19 112,1120 Connections Liquid line OD - in. (sweat) Suction line OD - in. 3/8 3/8 3/8 3/8 3/8 3/4 3/4 3/4 7/8 7/8 Refrigerant R-410A charge furnished 4 lbs. 8 oz. 5 lbs. 2 oz. 6 lbs. 8 oz. 8 lbs. 8 oz. 8 lbs. 12 oz. Outdoor Net face area - sq. ft. Outer coil Coil Inner coil Tube diameter - in. No. of rows Fins per inch 16.33 21.00 16.33 21.00 22.17 - - - - - - 15.75 20.25 21.33 5/16 5/16 5/16 5/16 5/16 1 1 2 2 2 26 26 22 22 22 Outdoor Diameter - in. Fan No. of blades Motor hp Cfm Rpm Watts 22 22 22 22 26 2 3 3 3 3 1/6 1/8 1/8 1/6 1/3 2610 2990 2820 3040 3920 825 825 825 825 825 160 160 160 190 180 Shipping Data - lbs. 1 pkg. 185 205 210 235 260 ELECTRICAL DATA Line voltage data - 60Hz 208/230V-1 ph 208/230V-1 ph 208/230V-1 ph 208/230V-1 ph 208/230V-1 ph 2 Maximum overcurrent protection (MOCP) amps 15 20 25 30 35 3 Minimum circuit ampacity (MCA) 12 15.4 18.4 17.4 21.9 Compressor Rated load amps Locked rotor amps 8.8 11.7 14.1 13.1 15.4 42.6 59.5 71.3 83.1 92.1 Outdoor Fan Full load amps Motor Locked rotor amps 1 0.74 0.74 1 2.6 1.9 1.65 1.65 1.9 3.2 CONTROLS - ORDER SEPARATELY E30 Smart Wi-Fi Thermostat 20A65 Remote Outdoor Temperature Sensor X2658 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 Compressor Hard Copeland 1OJ42 Start Kit LG 88M91 Compressor Low Ambient Cut -Off Switch 45F08 Compressor Timed -Off Control 47J27 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 5OA93 Indoor Blower Off Delay Relay 58M81 Low Ambient Kit (Fan Cycling) 34M72 Refrigerant 3/8 x 3/4 x 3/8 - 20 ft. 89J56 Line Sets 3/8 x 3/4 x 3/8 - 30 ft. 89J57 (Liq. x 3/8 x 3/4 x 3/8 - 40 ft. 89J58 Suc. OD x 3/8 x 3/4 x 3/8 - 50 ft. 89J59 Insulation 3/8 x 7/8 x 3/8 - 30 ft. 89J60 Thickness - 3/8 x 7/8 x 3/8 - 40 ft. 89J61 Length) • 3/8 x 7/8 x 3/8 - 50 ft. 89J62 NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. HACR type breaker or fuse. a Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL17XC1 - 1.5 to 5 Ton Air Conditioner / Page 7 SPECIFICATIONS General Model No. Data Nominal Tonnage EL17XC1-042 EL17XC1-047 EL17XC1-048 EL17XC1-060 3.5 4 4 5 Indoor Unit Expansion Valve (TXV) (If needed) 112,120 12J20 12J20 12J20 Connections Liquid line OD - in. (sweat) Suction line OD - in. 3/8 3/8 3/8 3/8 7/8 7/8 7/8 1-1/8 Refrigerant ' R-410A charge furnished 9 lbs. 2 oz. 9 lbs. 13 oz. 9 lbs. 8 oz. 12 lbs. 8 oz. Outdoor Net face area - sq. ft. Outer coil Coil Inner coil Tube diameter - in. No. of rows Fins per inch 22.17 22.17 24.93 29.09 21.33 21.33 24.13 28.16 5/16 5/16 5/16 5/16 2 2 2 2 22 22 22 22 Outdoor Diameter - in. Fan No. of blades Motor hp Cfm Rpm Watts 26 26 22 26 3 3 4 3 1/4 1/3 1/4 1/4 4060 3920 3700 4180 825 825 825 825 260 180 290 290 Shipping Data - lbs. 1 pkg. 260 260 275 300 ELECTRICAL DATA Line voltage data - 60Hz 208/23OV-1 ph 208/23OV-1 ph 208/23OV-1 ph 208/23OV-1 ph 2 Maximum overcurrent protection (amps) 35 35 50 50 3 Minimum circuit ampacity 24.6 27.5 33 31.3 Compressor Rated load amps Locked rotor amps 18.6 19.9 25 23.9 110 110 120 124.5 Outdoor Fan Motor Full load amps Locked rotor amps 1.4 2.6 1.7 1.4 3.2 - - - 3.2 3.2 CONTROLS - ORDER SEPARATELY E30 Smart Wi-Fi Thermostat 20A65 Remote Outdoor Temperature Sensor X2658 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 Compressor Hard Copeland 1OJ42 Start Kit LG 88M91 Compressor Low Ambient Cut -Off Switch 45F08 Compressor Timed -Off Control 47J27 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M81 4 Low Ambient Kit (Fan Cycling) 34M72 Refrigerant 3/8 x 7/8 x 3/8 - 30 ft. 89J60 Line Sets 3/8 x 7/8 x 3/8 - 40 ft. 89.1611 (Liq. x Suc. OD 3/8 x 7/8 x 3/8 - 50 ft. 89.162 x Insulation Thickness - 3/8 x 1-1/8 x 3/8 - 30 ft. X0570 Length) 3/8 x 1-1/8 x 3/8 - 50 ft. 73P91 • NOTE -Extremes of operating range are plus 10% and minus 5% of line voltage. Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. z HACR type breaker or fuse. s Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL17XC1 - 1.5 to 5 Ton Air Conditioner / Page 8 SOUND DATA 1 Model Octave Band Sound Power Levels dBA, re 10-12 Watts Center Frequency - HZ 1 Sound Rating Number (dBA) 2 Estimated Sound Pressure Level at Distance From Unit (dBA at distance in ft.) 125 250 500 1000 2000 4000 8000 3 5 10 15 50 018 55 60.5 65 67.5 61 55 49 72 65 60 54 51 40 024 56 60.5 67.5 69.5 62 58 51.5 73 65 60 54 51 40 030 56.5 62 68.5 66.5 63.5 58 50.5 72 64 59 53 50 39 036 56 65 68.5 67 64.5 58.5 51.5 73 66 61 55 52 41 041 54.5 61 66.5 65 64 59 52 72 65 60 54 51 40 042 55.5 63 68 68.5 63 56.5 47.5 72 65 60 54 51 40 047 58.5 63 67.5 66 64 59.5 51 73 65 60 54 51 40 048 55.5 63 69 69 66 62 54 75 68 63 57 54 43 060 1 58 1 62.5 1 69 1 69 65.5 61.5 53.5 74 66 61 55 52 41 NOTE - The octave sound power data does not include tonal correction. Tested according to AHRI Standard 270-2008 test conditions. z Estimated sound pressure level at distance based on AHRI Standard 275-2010 method for equipment located on the ground, roof, or on side of building wall with no adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 275. FIELD WIRING DISCONNECT t r THERMOSTAT DISCONNECT t SWITCH j (Required) i- _(By�thers) -j �_jBYOtherl ( s) � LENNOX LENNOX AIR HEATING UNIT CONDITIONER OR AIR HANDLER UNIT INSTALLATION CLEARANCES / See NOTES NOTES AOTELJ See NOTES Control .. A - Two Wire Power (not furnished) B - Two Power (not furnished). See Electrical Data C - Four Wire Low Voltage (not furnished). 18 ga. minimum D - Five Wire Low Voltage (not furnished). 18 ga. minimum All wiring must conform to NEC or CEC and local electrical codes. NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (914 mm) Clearance to one of the remaining two sides may be 12 in. (305 mm) and the final side may be 6 in. (152 mm). A clearance of 24 in. (610 mm) must be maintained between two units. 48 in. (1219 mm) clearance required on top of unit. EL17XC1 - 1.5 to 5 Ton Air Conditioner / Page 9 DIMENSIONS - UNIT Uf FE SUCTION LINE CONNECTION LIQUID LINE TOP VIEW CONNECTION C (depth) DISCHARGE AIR t SIDE VIEW BASE SECTION (Medium and Large Base) LIQUID LINE CONNECTION ELECTRICAL INLETS SUCTION LINE CONNECTION 4-1/4(108) (121) (121) f 1 (25) END VIEW Model A (Height) B (Width) C (Depth) D E F G H J K in. I mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm 018 31 787 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 024 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 030 31 787 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 036 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 041 35 889 35-1/2 902 39-1/21003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683 042 35 889 35-1/2 902 39-1/21003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683 047 35 889 35-1/2 902 39-1/21003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683 048 45 114330-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 060 45 114335-1/2 902 39-1/21003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683 EL17XC1 - 1.5 to 5 Ton Air Conditioner / Page 10 TXV USAGE Use this table for C35, CH23, and CR33 Field Installed TXV Match -Ups Outdoor Unit I Order Number 018 I12J18 024 I12J18 030 I12J18 036 I12J19 041 I12J20 042 I12J20 047 I12J20 048 I12J20 060 I12J20 CX35 and CHX35 coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. If a change out is required it will be listed in the "TXV SUBSTITUTIONS" table by size. The correct TXV must be ordered separately and field installed. C35 coils - Replace the factory installed RFC orifice with the expansion valve listed. CR33 and CH23 coils - Use the expansion valve listed. AHRI STANDARD 210/240-2023 Standard Ratings relating to cooling or heating capacities shall be net values, including the effects of circulating -fan heat, but not including supplementary electric heat. Power input used for calculating efficiency shall be the Total Power. Standard Ratings of units which do not have indoor air - circulating fans furnished as part of the model, i.e., Coil - only System, shall be established by subtracting from the total cooling capacity 1,505 Btu/h per 1,000 SCFM, and by adding the same amount to the heating capacity for non - mobile -home, non -Space Constrained units. Total Power for both heating and cooling shall be increased by 441 W per 1,000 SCFM of indoor air circulated. TXV SUBSTITUTION A general guide for replacing the factory installed TXV if the indoor unit (coil/air handler) is larger or smaller than the outdoor unit. Outdoor Unit Indoor Unit TXV Furnished TXV Replacement Size Tons Size Tons 018 1.5 30/36 2.5/3 12J19 12J18 018 1.5 36 3 12J19 12J18 018 1.5 42 3.5 12J20 12J18 018 1.5 48 4 12.120 12J18 018 1.5 49 4 12J20 12J18 018 1.5 50/60 4/5 12J20 12J18 018 1.5 51/61 4/5 12J20 12J18 018 1.5 60 5 12J20 12J18 024 2 42 3.5 12J20 12J18 024 2 48 4 12J20 12J18 024 2 49 4 12J20 12J18 024 2 50/60 5 12.120 12J18 024 2 51/61 5 12.120 12J18 024 2 60 5 12.120 12J18 030 2.5 42 3.5 12.120 12.118 030 2.5 43 3.5 12.120 12J18 030 2.5 48 4 12J20 12J18 030 2.5 49 4 12J20 12J18 036 3 24 2 12J18 12J19 036 3 30 2.5 12J18 12J19 042 3.5 24 2 12J18 12J20 042 3.5 30 2.5 12J18 12.120 042 3.5 30/36 3 12J19 12.120 042 3.5 36 3 12J19 12.120 048 4 30/36 2.5/3 12J19 12.120 048 4 36 3 12J19 12.120 TXV Ranges: 12J18 - 1.5 to 2.5 ton systems - Use on 2.5 ton (030) and lower systems. 12J19 - 3 ton systems - Use down to 2 ton (024) systems. 12J20 - 3.5 to 5 ton systems - Use down to 3 ton (036) systems. EL17XC1 - 1.5 to 5 Ton Air Conditioner / Page 11 REVISIONS Sections Description of Change Optional Accessories Updated Line Sets available. Specifications Removed RFC orifice sizes. TXV Usage Removed references to RFC orifices. LENNOX AJ © �IMEMM COMPANr ntertek Visit us at www.Lennox.com For the latest technical information, www.LennoxPros.com Contact us at 1-800-9-LENNOX NOTE - Due to Lennox' ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2023 Lennox Industries, Inc.