BLD2010-0521% .0 & 10 %J I I Pr'oP'EXI Fire Sprinkler Adapter Tees -�Pubmlttal Information 'g Zevislon A.- Feb. It 2008 Wm fn;, qnm, ob Name: Pa rt No. Ordered: n9ineer: Date Submitted: ontractor: Submitted By: lanufacturer"s R��presentabve. Approved By: A 1P n rpmdl tA vi- NPT Tapped Hole e G aterial: 300 Ser'es Stainless Steel C I 0 E I se - 'i ca- J'O�n U, van -0 uct .1 & F! �h _-P ProPEX8� Fire Sprinkler Adapter Tee is used in .ijunction with the respective Reliable'9 Sprinkler to vide a multi -purpose residential fire sprinkler tem 1 . The system is installed with the cold -potable tion of the Uponor plumbing system for residential )lications. The connections are made with Uponor PEX fittings. The fittings are designed for use only -1 3/4 " Wirsbo AQUAPEXO tubin or I" Wirsbo AQUAPEX ing in the Uponor AQUASAFE Looped System. A NPT Tapped Hole B L �j L;-J C _j E R., a, tt V 0 1 t b 's On i ti A N Lffil, Or IroPEX H re Sprinkler Adapter Tee, 3/4" PEX x 1/2" FNPT Q7527575 2.89 ft 1.41 Pf 2.25n 1.88 tr 2.50 11 0.408 lbs. IroPEX Fire Sprinkler Adapter Tee, I" PEX x 1/2" FNPT Q7521050 3�61 it 1.5411 2.63 it 1.88 it 2�50 10 0.268 lbs. 'a the appropriate Uponor ProPEX Ring Fo r the tubing. For more information, refer to the Uponor AQUASAFE:�� Looped System Installation e. quard5.,.- ICSA B137.5,; ASTM F877,- ASTM F1960; UL 1821; ULC/ORD - C 199 P UPC; NSPC; IRC; IMC; NPC of Canada /NSF 14- and 61-cer-tified; ICC ESR 1099-1 HUD MR 1269; 1APMO 3558 1 p. n t i ac -gn t -e i. s d' C t IZ - - - r -. - _- - - . . 0 _3' Plumb-Ing Systems Uponor, Inc. Uponor Ltd. S925 148th Street West 6S5 Park Street Apple Valley, MN 55124 USA Reginca, SK S4N SNI CANADA Phone: (800) 321-4739 Phone: (888) 994-7726 Fax.- (952) 891-1409 Fax: (800) 638-9517 www.uponor-usa.com www.uponor.ca Reliableo Sprinkler is a registered trademark of the Reliable Automatic Sprinkler Co., Inc. r f t• Final Calculations -Hazen-Williams A-Pex Design Services, Inc. Page 6 WILLOWDALE WEST BLDG UNIT B -One Head Calculation (H.16) Date 7/21/2010 ; Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv '**"*" Notes *'*'�` Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0 T.26 -2.92 0.862 0.0 15.000 9.891 to 150.0 0.0 0.0 3.465 T.27 4.14 0.0121 0.0 15.000 0.182 Vel = 2.28 T.27 0.0 0.862 1 Utb 0.8 18.000 13.538 to 150.0 0.0 2.000 0.0 T.22 4.14 0.0121 0.0 20.000 0.242 � Vel = 2.28 0.0 4.14 13.780 K Factor = 1.12 T.26 2.92 0.862 1 Utb 0.8 6.000 9.891 to 150.0 0.0 2.000 0.0 H.11 2.92 0.0064 0.0 8.000 0.051 Vel = 1.61 H.11 0.0 0.862 0.0 16.000 9.942 to 150.0 0.0 0.0 0.0 H.3 2.92 0.0064 0.0 16.000 0.102 Vel = 1.61 H.3 0.0 0.862 1 Utb 0.8 10.000 10.044 to 150.0 0.0 2.400 0.0 T.18 2.92 0.0063 0.0 12.000 0.076 Vel = 1.61 T.18 0.47 0.862 0.0 23.000 10.120 to 150.0 0.0 0.0 3.465 T.17 3.39 0.0084 0.0 23.000 0.194 Vel = 1.86 0.0 3.39 13.779 K Factor = 0.91 T.25 0.47 0.862 1 Utb 0.8 3.000 10.112 to 150.0 0.0 2.000 0.0 H.9 0.47 0.0002 0.0 5.000 0.001 Vel = 0.26 H.9 0.0 0.862 0.0 2.000 10.113 to 150.0 0.0 0.0 0.0 T.20 0.47 0.0005 0.0 2.000 0.001 Vel = 0.26 T.20 0.0 0.862 0.0 7.000 10.114 to 150.0 0.0 0.0 0.0 H.5 0.47 0.0001 0.0 7.000 0.001 Vel = 0.26 H.5 0.0 0.862 0.0 5.000 10.115 to 150.0 0.0 0.0 0.0 T.19 0.47 0.0002 0.0 5.000 0.001 Vel = 0.26 T.19 0.0 0.862 0.0 4.000 10.116 to 150.0 0.0 0.0 0.0 H.2 0.47 0.0002 0.0 4.000 0.001 Vel = 0.26 H.2 0.0 0.862 1 Utb 0.8 11.000 10.117 to 150.0 0.0 2.000 0.0 T.18 0.47 0.0002 0.0 13.000 0.003 Vel = 0.26 OA 0.47 10.120 K Factor = 0.15 T.24 13.00 1.054 1 T 2.44 11.000 14.025 to 150.0 OA 2.440 1732 S.1 13.0 0.0379 0.0 13.440 0.510 Vel = 4.78 S.1 0.0 1.61 2E 12.089 350.000 16.267 to 150.0 0.0 12.088 11.732 'Fixed loss = 10 MTR 13.0 0.0048 0.0 362.088 1745 Vel = 2.05 Computer Programs by Hydratec Inc. Route 111 Windham N.H. U5A 03087 0 � � • * r 4A = 1AN �A = 1 035_ ROR-A � �� �� �� , 8.43' Y u.s,s,s J .+i 4 1 i A f G +g f a t 1 r 4 y i r t1 r r �. dk. I Installation Guidelines 1. For Systems des ' ig'ned r'n accordance with NFPA 13, 13D and 13R, where specific UL Listed flows -are. not required, cons'ult with the local Authority Havibg Jurl*sdiction regarding the number of - design sprinklers for sloped ceilings having pitch greater than Y,2 (9.4'). 2. Installation of UL listed residential sr)rinklers, under sloped ceilings shall be limite'd10 a typ. e of unobstructed construction consistina of flat smooth r cei'lings, as defined by NFPA 13, having a maximum pitch of 4112 (1840) or 8/12 (33.7). 3. Where listed install hori*zontal sidewall sprinklers alon the wall below the slor)ed ceHina when discharae 9 a is directed across � e slope and install at- the peak below the sloped ceiling when discharge j*s directed down the slope. Always align the sprinkler deflector parallel with the direction of the sloped ceiliong. 4. Residential HSW sprinklers located closedio the peak of the ceiling shall have the defledtors loca'tedhot more than 3 ft. (1m) vertically down from the peak. A 5. Spacing of residential HSW sprinklers under. slop.ed ceilings is measured along th'e s1ope'whe''n_'de'te'r . m ining the distance off of walls and between sprinklers. D. Measure listed areas of coverage along the sloped ceiling. The actual floor coverage aroa will be less than the listed area. 7b For coverage areas less than the listed mverag.e area shown in Tables I through 6, use' thL:-% M'inimu'm' flow requirement for next largest listed coverag- e- a.-rea. _J Minimum spacing between horizontal sidewall sprinklers is 8 ft. (2.4 m). Minimum distance from a horizontal sidewall sprinkler and an adjacent wall is 4 (102 mm). Where installation of F1 Res 40 horizontal sidewall sprinklers provide discharge across a slope having a maximum pitch ot 8/12, F2 escutcheons may be used for surface mounting only. D. Hydraulic Requirements - a. Fo r ' NFPA 13D Systems, the number of design sprinklers shall include all sprinklers within a compartment, u to a maxi -mum of two sprinklers (whe ' re specific L Listed flows are required) that requires the greatest hydraulic demana. Excepfion: For F1 Res 40 horizontal sidewall s n - nkler's, where discharge is directed across a srope having a maximum pitch of 8/12 and the compqrtment that requires the greatest hydraulic demand is large enou h where three (3) or more 0 r sprinklers are requi'redyor adequate coverag-e ' the . 9 a minimum number of desi'gn sprinklers within that compartment shall be three (3), where specific UL Listed flows are required. b. For NFPA 13R Systems, the number of design spr - inklers shall include all sprinklers within a compartment, up to a maximum of four (4) spM ' Hers (where specific UL Listed flows are required), that requires the greatest hydraulic demand. c. For NFPA 13 systems, the design area shall be the area that includes the four (4) hydraulically most d andIng sprinklers. The minimum re uired dischar�e from each of the four hydrauill'cally demanciing sprinklers shall be the greater of the following.- (1) In accordance with the minimum flow rates indicated by the, individual I.isfinps (that alrea'dy 'r 2, will provide a minimum densi oi 0. 1 Q'PrrVft ), (2) A calculated value base on d'61i'vering a minimum of 0. 1 gpm/ft2 ov th design area. I I Because of the varied nature of residential construction features, there will be some compartment designs which cannot be fully sprinklered in accordance with NFPA 13, 13D, or 13R. In these instances, consult the Authority Having Jurisdiction (AHJ) for guidance and approval. This includes sloped ceilings having a pitch greater than 8/12 (33.70). 12. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACE IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before thi's time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING I HE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. equipment presented in this ' bulletin is to be Install.ed in accordance with the latest Pertinent Standards of the National Fire Pfolection Association, Factory Mutual Research :>oration, or othef sim-11ar organizations and also wfth the provisions of governmental codes or ordinances, whenever applicable. Jucts n-onufactured and distributed by RELIABLE have been protecting life and property tor over 80 years, and are installed and serviced by the mst highy quakfied and gable sprinkler conLradors located br bughout the United States, Canada and foreign counines. inufactured by The Reliable Automatic Spn'nkler Co., Inc. 1Q Recycled f Water Supply Curve (C) A-Pex Design Services, Inc. Page 2 WILLOWDALE WEST BLDG UNIT C -Two Head Calculation (H.2 & H.1) Date 7/21/2010 City Water Supply C1 -Static Pressure 55 C2 -Residual Pressure: 50 C2 -Residual Flow 300 150 140 130 P 120 R 110 E 100 g 90 S 80 � 70 R 60 E 50 40 30 20 10 C�Ya D1 50 100 150 200 250 300 FLOWN ^ 1.85 ) 350 �11 Demand: D1 -Elevation 10.394 D2 -System Flow 26.0927 D2 -System Pressure 44.741 Hose (Adj City) Hose (Demand) D3 -System Demand 26.0927 Safety Margin 10.204 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 450 a