Loading...
BLD2023-1115_Other_9.5.2023_5.25.05_PM_3765324Job Name: System Reference: Date: MITSUBISHI /_ ELECTRIC FEATURES • Variable speed INVERTER -driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 51 dB(A) • High-pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life o Rated for 2,000 hours spraying time per ASTM B117 Standard ENERGY STAR products are third -party certified by an EPA -recognized Certification Body. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling' (Non -Ducted H Mix // Ducted) Maximum Capacity BTU/H 22,000 H 22,000 H 22,000 Rated Capacity BTU/H 22,000 H 22,800 H 23,600 Minimum Capacity BTU/H W 11,600 H 11,300 H 11,000 4,040 H 2,830 H 1,620 Maximum Power Input Rated Power Input W % 1,610 // 1,855 H 2,100 99.0, 99.0 H 99.0, 99.0 H 99.0, 99.0 Power Factor (208V, 230V) Heating at 47°F2 (Non -Ducted H Mix H Ducted) Maximum Capacity BTU/H 30,600 H 30,600 H 30,600 Rated Capacity BTU/H 25,000 H 24,800 H 24,600 Minimum Capacity BTU/H 18,100 // 17,700 H 17,300 Maximum Power Input W 3,700 // 3,900 H 4,100 Rated Power Input W 1,740 // 1,815 H 1,890 Power Factor (208V, 230V) % 99.0, 99.0 // 99.0, 99.0 // 99.0, 99.0 Heating at 17°F3 (Non -Ducted H Mix // Ducted) Maximum Capacity BTU/H 21,000 H 19,600 H 21,000 Rated Capacity BTU/H 14,300 H 14,450 H 14,600 Maximum Power Input W 2,860 H 2,910 H 2,960 Rated Power Input W 1,390 // 1,475 H 1,560 Heating at 5°F4 (Non -Ducted // Mix H Ducted) Maximum Capacity BTU/H 19,800 // 19,800 H 19,800 Maximum Power Input W 3,100 // 3,205 H 3,310 Efficiency (Non -Ducted H Mix // Ducted) SEER2 20.0 H 18.0 H 16.0 EER21 13.6 // 12.4 H 11.2 HSPF2 (IV) 10.0 H 9.3 H 8.6 COP at 47°F2 4.2 H 4.0 H 3.8 COP at 17°F at Maximum Capacity3 2.15 H 2.11 H 2.07 COP at 5°F at Maximum Capacity' 1.87 // 1.81 H 1.75 ENERGY STAR® Certified Yes H No H No Electrical Electrical Power Requirements Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187-253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size A 25 Recommended Wire Size (Indoor- Outdoor) AWG 14 Minimum Circuit Ampacity A 22.1 Maximum Overcurrent Protection A 25 Fan Motor Full Load Amperage A 2.43 Outdoor unit Airflow Rate (Cooling / Heating) CFM 2,133 / 2,243 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate Fin Coil Heat Exchanger Coating Blue Fin Coating Sound Pressure Level, Cooling' dB(A) 51 Sound Pressure Level, Heating2 dB(A) 55 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model SNB220FCGMC Compressor Rated Load Amps A 12 Compressor Locked Rotor Amps A 13.7 Compressor Oil Type H Charge oz. FV50S H 23.7 Base Pan Heater Optional Unit Dimensions W: In. [mm] 37-13/32 [950] D: In. [mm] 13 [330] H: In. [mm] 31-11/32 [796] Package Dimensions W: In. [mm] 41-11/32 [1,0501 D: In. [mm] 17-5/16 [440] H: In. [mm] 38-31/32 [990] Unit Weight Lbs.[kg] 142 [64.3] Package Weight Lbs.[kg] 174 [78.9] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum'") °FDB 115 / 14 Cooling Thermal Lock -out / Re -start Temperatures °FDB 10.4 / 14 Heating Intake Air Temp (Maximum / Minimum) °FWB 65 / 5 Heating Thermal Lock -out / Re -start Temperatures °FDB 1.4 / 5 Refrigerant Pre -Charged Refrigerant Amount Lbs, oz 6.0, 13.0 Maximum Pre -Charged Piping Length Ft. [m] 98.0 [30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.216 [20] NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB 3Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB "Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. I5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Number of Connected IDU Indoor unit connection Minimum Number of Connected IDU Minimum connected capacity BTU/H Maximum connected capacity BTU/H 3 2 12,000 28,000 Liquid Pipe Size O.D. (Flared) Gas Pipe Size O.D. (Flared) Total Piping Length Piping Maximum Height Difference, ODU above IDU Maximum Height Difference, ODU below IDU Farthest Piping Length from ODU to IDU Maximum Number of Bends for IDU In.[mm] A,B,C: 1/4 [A,B,C: 6.35] In.[mm] A: 1/2; B,C: 3/8 [A: 12.72: B,C: 9.52] Ft. [m] 230 [70] Ft. [m] 49 [15] Ft. [m] 49 [15] Ft. [m] 82 [25] 70 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 21-leating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 31-leating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. I5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130 % , the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Hail Guards Hail Guard ❑ HG-A9 Mini -Split Wire 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 Optional Defrost Heater Optional Defrost Heater ❑ PAC-645BH-E Stand Outdoor Unit Stand —12" High ❑ QSMS1201 M Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. (Foundation Bolt M10) rsrar min, 1.FREE SPACE Unit: inch (mm) LIO 1/4'(06.35)FLARE GAS 3/8'(09.52)FLARE LIO 1/4'(06.35FLARE GAS 1/2'1012.7)FLARE 2.SERVICE SPACE o E `o E Conduit plates a Conduit connector 3-15/16° Of more SERVICE SPACE 13-25/32' ❑r more 13-25/32" or more Lock nut 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com ' C EtI OS FORM# MXZ-3C24NA4 - 202307 Intertek Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.