BLD2023-1126_Manufacturer_Specifications_and_Installation_Instructions_9.7.2023_7.57.44_AM_3768334
Job Name: System Reference: Indoor Unit: PVA-A42AA7 Date: Outdoor Unit: PUZ-HA42NKA III��i��IIIIIIIIIIIIIIIIIIIIIIVm °" IIIullllllllllllllllllllllllllllllllllllllllli� � IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII III!Illlllllllllllllllllllllllllllllllllllllllllli ''i0111111�iilllllllllllllliol�llllllli INDOOR UNIT FEATURES • Ducted air handler provides a solution to cool and heat large zones • Highly efficient totally enclosed ECM motor • Selectable external static pressure: 0.30, 0.50 and 0.80 in.WG with 3 fan speeds at each static setting • 1 inch R4.2 fiberglass free insulation reduces condensation and boosts efficiency • Positive pressure cabinet with air leakage of less than 1.0% at 1.0 in.WG • Unique blow through design allows simple coil cleaning when the blower is removed • Multi -position installation: horizontal (left or right), vertical (up or down). For downflow configurations, the CMA-1 is recommended for proper management of condensate to prevent water blow -off in certain conditions • Optional electric heat kit for additional heat capacity • Optional humidifier control and ERV control OUTDOOR UNIT FEATURES • Variable speed INVERTER -driven compressor • High heating capacity: flash injection circuit maintains 100% heating capacity at 5°F outdoor temperature • Wide heating range: heating performance down to -13°F (average of 80% heating capacity) • High speed heating at start up: Hyper -Heating INVERTER® reduces the time for heating at start up by about half compared to standard models • Suction accumulator pre -charged with refrigerant volume for piping length up to 100 ft. • Twinning of two indoor units possible with the 36 kBTU/H model • High pressure/temperature protection Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Capacity Rated Capacity BTU/H 42,000 BTU/H 42,000 Minimum Capacity BTU/H 19,000 Cooling Maximum Power Input W 4,270 Rated Power Input W 4,270 Moisture Removal Pints/h 7.2 Sensible Heat Factor 0.76 Power Factor % 88.4 Maximum Capacity BTU/H 54,000 Rated Capacity BTU/H 48,000 Heating 47°FZ Minimum Capacity BTU/H 18,000 at Maximum Power Input W 4,870 Rated Power Input W 4,010 Power Factor % 88.1 Maximum Capacity BTU/H 48,000 Heating 17°F3 Rated Capacity BTU/H 42,400 at Maximum Power Input W 6,700 Rated Power Input W 4,990 Heating 5°F4 Maximum Capacity BTU/H 48,000 at Maximum Power Input W 7,360 SEER 15.3 EER' 9.8 Efficiency HSPF (IV) 11.0 COP at 47°FZ 3.50 COP at 17°F in Maximum Capacity 2.09 COP at 5°F in Maximum Capacity 1.91 Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 198 — 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208V / 230 Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 Recommended Fuse/Breaker Size (Outdoor) A 40 Recommended Wire Size (Indoor - Outdoor) AWG 14 MCA A 5.63 Fan Motor Full Load Amperage A 4.50 Fan Motor Output W 430 Airflow Rate, Dry CFM 1040-1262-1485 Indoor Unit Airflow Rate, Wet CFM n/a External Static Pressure in.WG 0.30-0.50-0.80 Sound Pressure Level dB(A) 34-38-42 Drain Pipe Size In. (mm) 3/4 FPT (19.05) Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Condensate Lift Mechanism, Maximum Distance Ft. (m) n/a Heat Exchanger Type Plate fin coil External Finish Color Galvanized steel cabinet -Powder coated Slate Gray Unit Dimensions // Grille Dimensions W: In. (mm) 25 (635) D: In. (mm) 21-5/8 (548) H: In. (mm) 59-1/2 (1511) Unit Weight Lbs. (kg) 172 (78) Indoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum) °F 90 DB, 73 WB / 66 DB, 59 WB Temperature Range Heating Intake Air Temp (Maximum / Minimum) °F 82 DB / 50 DB MCA A 37 MOCP A 44 Fan Motor Full Load Amperage A 0.4+0.4 Fan Motor Output W 86+86 Airflow Rate CFM 3,320 Refrigerant Control Electronic Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Cross fin Sound Pressure Level, Coolingi dB(A) 49 Sound Pressure Level, Heating2 dB(A) 51 Compressor Type INVERTER -Driven Twin Rotary Compressor Model ANB42FJTMT Outdoor Unit Compressor Rated Load Amps A 19 Compressor Locked Rotor Amps A 28 Compressor Oil Type // Charge oz. FVC68D // 54 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater Option (PAC-SJ20BH-E) Unit Dimensions W: In. (mm) 41-3/8[1,050] 13 + 1-3/16 (330 + 30) D: In. (mm) H: In. (mm) 52-11/16 (1,338) Package Dimensions W: In. (mm) 42-15/16 (1,090) D: In. (mm) 17-11/16 (450) H: In. (mm) 56-1/4 (1,428) Unit Weight Lbs. (kg) 287 (130) Package Weight Lbs. (kg) 313 (142) Cooling Intake Air Temp (Maximum / Minimum) °F 115 DB / 0* DB Outdoor Unit Operating Temperature Range Heating Intake Air Temp (Maximum / Minimum) °F 70 DB, 59 WB / -13 DB, -13 WB Thermal Lock -out / Re -start Temperatures** °F n/a Refrigerant Type R410A Charge Lbs, oz 13,4 Gas Pipe Size O.D. (Flared) In.(mm) 5/8 (15.88) Piping Liquid Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52) Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Piping Length Ft. (m) 245 (75) Maximum Height Difference Ft. (m) 100 (30) Maximum Number of Bends 15 Notes AHRI Rated Conditions (Rated data is determined at a fixed 1 Cooling (Indoor // Outdoor) T 80 DB, 67 WB H 95 DB, 75 WB 70 DB, 60 WB // 47 DB, 43 WB 2Heating at 47°F (Indoor // Outdoor) T compressor speed) 3Heating at 17°F (Indoor // Outdoor) T 70 DB, 60 WB H 17 DB, 15 WB Conditions 4Heating at 5*F (Indoor // Outdoor) °F 70 DB, 60 WB H -4 DB, -5 WB *Wind baffles required to operate below 23*F DB in cooling mode. PUZ with wind baffle: 0T - 115T. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Wireless Signal Receiver Wireless Signal Receiver Wireless Remote Controller Wireless Remote Controller ❑ PAR-SA9CA-E ❑ PAR-FA32MA-W ❑ PAR-SL100A-E ❑ PAR-FL32MA-E Controller Kit with i-see SensorTM kumo touchTm RedLINKTM Wireless Controller ❑ PAR-SA92MW-E ❑ MHK2 Deluxe MA Remote Controller ❑ PAR-40MAAU Simple MA Controller ❑ PAC-YT53CRAU-J Touch MA Controller ❑ PAR-CT01 MAU-SB Airzone ZBS Wired Blueface Principal Controller White ❑ AZZBSBLUEFACECB Airzone ZBS Wired Think Controller White ❑ AZZBSTHINKCB Airzone ZBS Wireless Think Controller White ❑ AZZBSTHINKRB ❑ AZZBSLITECB Airzone ZBS Wired Lite Controller White Airzone ZBS Wireless Lite Controller White ❑ AZZBSLITERB Wired Remote Sensor ❑ PAC-SE41TS-E Wireless Temperature and Humidity Sensor ❑ PAC-USWHS003-TH-1 Flush Mount Remote Temperature Sensor ❑ PAC-USSEN001-FM-1 Wireless Interface 2 ❑ PAC-USWHS002-WF-2 Thermostat Interface ❑ PAC-US444CN-1 kumo station® ❑ PAC-WHS01 HC-E USNAP Interface ❑ PAC-WHS01 UP-E IT Extender ❑ PAC-WHS011E-E BACnet® and MODBUS® Interface ❑ PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter ❑ CN24RELAY-KIT-CM3 Connector cable for remote display ❑ PAC-SA88HA-EP Connector for CN32 (remote on/off) ❑ PAC-SE55RA-E Remote Operation Adapters ❑ PAC-SF40RM-E Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 - 2081230V (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W Separate Power Terminal Block Kit ❑ SPTB1 Electric Heat Lockout Control ❑ ETC-211000-MIT Condensate Management Kit for downflow installation ❑ CMA-1 10kW Electric Heater ❑ EH10-MPA-L(B) 15kW Electric Heater 17kW Electric Heater ❑ EH15-MPAS- L(B) ❑ EH17- MPAS-L(B) 1 Unable to use with wireless remote controller Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Front Wind Baffle Drain Socket Defrost Heater Centralized Drain Pan ❑ PAC-SH96SG-E (two pieces are required) ❑ WB-PA3 (two pieces are required) ❑ PAC-SG61 DS-E ❑ PAC-SJ20BH-E ❑ PAC-SH97DP-E M-NET Converter ❑ PAC-SJ85MA-E M-NET Converter Control/Service Tool ❑ PAC-SJ95MA-E c PAC-SK52ST Hail Guard ❑ HG-A2 Condensing Unit Mounting Pad 24" x 42" x 3" ❑ ULTRILITE2 Outdoor Unit Stand-12" High ❑ QSMS1202M Outdoor Unit Stand-18" High ❑ QSMS1802M Outdoor Unit Stand-24"High ❑ QSMS2402M Heavy Duty Wall Mounting Bracket for Outdoor Units —Coated Steel ❑ QSWB2000M-1 Heavy Duty Wall Mounting Bracket for Outdoor Units-316 Series Stainless Steel ❑ QSWBSS 3/8" x 5/8" x 10' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-10 3/8" x 5/8" x 15' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-15 3/8" x 5/8" x 30' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-30 3/8" x 5/8" x 50' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-50 3/8" x 5/8" x 65' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-65 3/8" x 5/8" x 100' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-100 Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. w_e_,ya_V_Vi Top Unit:mm(in.) view Note 1.Keep the service space for maintenance at the front. 026 Knockout Hole o26 Knockout Hole (indoor/ Outdoor unit connection) (Remote controller transmission) Fr( vl C BD Right side vl w Model ®Nominal Filter Size Duct Connec0on PVA-Al2AA7 508 x 406.4 x 25.4 376 x 402 PVA-A18AA7 20 x 16 x 1 1413/18 x 15-7/8 PVA-A24AA7 508 x 508 x 25.4 477 x 402 PVA-A30AA7 20 x 20 x 1 16.13/16 x 15.7/6 PVA-A36AA7 508 x 609.6 x 25.4 579 x 402 PVA-A42AA7 20 x 24 x 1 22.13/16 x 15.7/8 Unit: mm (in.l Model A IS C D E F G H J O)Gas Pipe ®Liquld Pipe PVA-AI2AA7 PVA-AI8AA7 432 (17) 376 (14-13/16) 281 (11-1/8) 224 (8.7/8) 1275 (50.1/4) 680 (26.13/16) 823 (32.7/16) 735.5 (29) 360 (14-3116) 4)12.7 (1/2) 06.35(114) PVA-A24AA7 PVA-A3 534 (21) 477 (18.13/16) 382.6 (15.1/8) 266.5 (10.1/2) 1378 (54.1/4) 737 (29.1/16) 953.5 (37.9/16) 792 (31.3/16) 461 (18.3116) PVA-A36AA7 AA7 015.88 (518) 09.52(318) PVA-A42AA7 635 (25) 578 (22.13/16) 464.6 (19.1/8) 317.5 (12-1/2) 1511 (59.1/2) 798.5 (31.7/16) 1053 (41.1/2) 853.5 (33.5I8) 563 (22.31i6) Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. PUZ-HA42NKA 1 FREE SPACE (Around the unit) The diagram below shows a basic example. Explan ion of particular details are given in the Installation manuals at. FREE Min. <3%B> I r5iInn m 2 SERVICE SPACE Dimensions of space needed for sery shown in the below diagram 1D ReM1ii GAS pipe—diion(FLARE) 015.88(NF) (2)• •Rer4—t LIQUID pipe mnnec8on(FLARE) 09,52(SAIF) 91 Irdirarion of STDP VALVE connecron lora4on. Piping Knock -Out Hole Details 3 FOUNDATION BOLTS Please secure the unit firmly with 4 foundation (MI )<W318>) bolts.(B.hS and washers must be purchased batty.) FORM# PVA-A42AA7 / PUZ-HA42NKA - 202003 4 PIPING -WIRING DIRECTIONS Piping and wiring connections an be made from 4 directions: FRONT, Right, Rear and Belm in rmMM 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com A. 1 CERTIFIED® Specifications are subject to change without notice. © 2020 Mitsubishi Electric Tirane HVAC US LLC. All rights reserved.