BLD2022-1543_Site_Plan_9.12.2023_2.16.05_PM_3778544CONSSLING SULTING Scott E. Wyssling, PE Coleman D. Larsen, SE, PE Gregory T. Elvestad, PE Revolution Solar 9981 West 190th Street Unit K, Mokena, IL To Whom It May Concern: 76 North Meadowbrook Drive Alpine, UT 84004 office (201) 874-3483 swyssling@wysslingconsulting.com October 31, 2022 Revised September 7, 2023 Re: Engineering Services Maughan Residence 1044 Daley Street, Edmonds, WA 7.200 kW System We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Assumed prefabricated wood trusses at 24" on center. All truss members are constructed of 2x4 dimensional lumber. Roof Material: Composite Asphalt Shingles Roof Slope: 20 degrees Attic Access: Inaccessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Live Load = 20 psf (reducible) — 0 psf at locations of solar panels • Ground Snow Load = 20 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 97 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2018 Washington State Residential Code (20181RC), including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% forgravity elements and 110% forseismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Roof Tech installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non -uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal for a M5x60mm wood screw in '/2" plywood/OSB board is 43 Ibs per screw (per APA technical note E830d). Connection on the roof is utilizing five (5) M5x60mm wood screws into the existing decking to resist uplift forces. Contractor to verify installation to be performed in accordance with the manufacturer's recommendations. Based on five (5) M5x60mm wood screws into sheathing, 215 Ibs of uplift resistance is provided per attachment. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 24" on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2018 Washington State Residential Code, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V truly yours, Scott E. Wyssli , PE Washington License 111163 �� E• W G0 H � 0,,�'P�p 20111 l63 � QISTERQ Ss�O N A L Signed 9/07/2023 VVYSSLING CONSULTING GENERAL NOTES 1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING 2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110 3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES 5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.81 6. DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.311 7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE it MAP VIEW: ; ri I t . , osier sr 1rD Daley S oWs,liiM WA�9R (7:WSA C t , •4 ■ pr St &p�ague St � �. • � r i mn'gbor I Park t y1{e ,sue PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS EQUIPMENT: AC System Size: 5.24 kW AC / 5.24 kVA DC SYSTEM SIZE: 7.20 kW DC (15) HANWHA Q.PEAK DUO XL-G10.D/BFG 480 PV Mo 15 ENPHASE IQ8A-72-2-US 240V Inverters RACKING: RT-MINI II - 24" O.C. APPLICABLE GOVERNING CODES 2020 NEC 2018 IRC 2018 IMC 2018 IFGC 20111163 Signed 9/07/2023 SITE SPECIFICATIONS OCCUPANCY: R-3 ZONING: RESIDENTIAL Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION 1ULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.24 kW AC / 5.24 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (15) HANWHA Q.PEAK DUO XL-G10.D/BFG 480 PV Modules 1 (15) ENPHASE IQ8A-72-2-US (240V) IJ Inverter(s) �y►�.r.�.1► ley:•.�.ni►rr'•ln3r[.mrlrrl•�.���r:�r�■I SHEET INDEX: PV01 COVER PAGE PV02 SITE PLAN PV03 ROOF ATTACHMENTS PV04 MOUNTING DETAIL PV05 LINE DIAGRAM PV06 ELECTRICAL CALCS PV07 LABELS PV08 PLACARD PV09 SITE PHOTOS DRAWN BY: D.SANCHEZ DATE: 9/5/2023 COVER PAGE - PV01 DALEY ST A 4'-3" CLOSE UP OF HOUSE EQUIPMENT LEGEND: UTILITY METER ac AC VISABLE,DISCLOCKABLE, LABELED ENV INVERTER NNECT sub SUB PANEL SD SERVICE DISCONNECT PV MODULES METER SOCKET ARRAY DETAILS: MOUNTING PLANE: AZIMUTH: TILT: MP1 1800 20° MP2 1800 200 MP2 MP1 VISIBLE, LOCKABLE, FIRE ACCESS PATHWAY (T TYP) LABELED AC DISCONNE MSP MAIN SERVICE PANEL Pv (FOR UTILITY PV METER) � COMBINER BOX Lc LOAD CENTER BAIT BATTERY(IES) JB JUNCTION BOX PROPERTY LINE LOCATED WITHIN 10' OF UTILITY METER Jim L*-*li- - L�11:91941§ T IN I V� Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION JULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.24 kW AC / 5.24 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (15) HANWHA Q.PEAK DUO XL-G10.D/BFG 480 PV Modules (15) ENPHASE IQ8A-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITYZST&ICT I 0 �� 20111 V ��` Q�Sf O N A Signed 9/07/2023 DRAWN BY: D.SANCHEZ CT DATE: 9/5/2023 SITE PLAN - PV02 • HOUSE ELEVATION 2 57'-1 " T TYP EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: RAIL MANUFACTURER: CHIKO RAIL ROOF TYPE: COMP SHINGLE PV MODULE COUNT: 15 RAIL PART NUMBER: 7-RB ROOF FRAMING: MANUFACTURED TRUSS ARRAY AREA: MODULE COUNT * 24.88 ft2 = 373.20 ATTACHMENTS RT-MINI II RAFTER/TOP CHORD SIZE: 2" X 4" ROOF AREA: 2893.61 ft2 ATTACHMENT CITY: 53 RAFTER/TOP CHORD SPACING: 24" PERCENT OF ROOF COVERED: 13% SPLICE CITY: 11 ATTACHMENT SPACING: 24" ARRAY WEIGHT: MODULE COUNT * 64.2 Ibs = 963.00 Ibs MIDCLAMP CITY: 30 POINT LOAD: ARRAY LBS/ATTACHMENTS = 18.17 t ENDCLAMP CITY: 21 DISTRIBUTED LOAD: (Ibs/ft2) (ARRAY) WEIGHT/AREA = 2.6 Ibs/ft2 Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION JULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.24 kW AC / 5.24 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (15) HANWHA Q.PEAK DUO XL-G10.D/BFG 480 PV Modules (15) ENPHASE IQ8A-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY WSTI[ICT • ,t E • W GOB s N ' �0 20111163 tV`� �?ISTE1L �SIO N A L V, Signed 9/07/2023 J DRAWN BY: D.SANCHEZ DATE: 9/5/2023 ROOF ATTACHMENTS - PV03 CHIKO END CLAMP PV MODULE RAIL 1 END CLAMP DETAILS _ Deck installation : Fastened to the sheathing (Plywood or OSB) with Sea. M5.0 X 60 mm wood screws. "IKO MID CLAMP �� MID CLAMP DETAILS m O.............. . ...... 3.54 inch (90mm) .60 inch (15.4mm) � DETAIL, MOUNTING AND FLASHING PV MODULE RAIL mDT Ural s ^JVI GAJ. V ^ VV w5. 0 x 60 RT—MINI II / 1 2 l 24" MAX SPAN MAX. FRONT VIEW i RAIL 6" MAX / -- RT MINI II 2'-8" MIN - 3'-10" MAX (E) RAFTER/TOP CHORD 10" MIN - 1 '-4" MAX / SIDE VIEW PV MODULE RAIL 2'-8" MIN - 3'-10" MAX (E) RAFTER/TOP CHORDS 3 10" MIN - 1 1-4" MAX EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: RAIL MANUFACTURER: CHIKO RAIL ROOF TYPE: COMP SHINGLE PV MODULE COUNT: 15 RAIL PART NUMBER: 7-RB ROOF FRAMING: MANUFACTURED TRUSS ARRAY AREA: MODULE COUNT * 24.88 ft2 = 373.20 ATTACHMENTS RT-MINI II RAFTER/TOP CHORD SIZE: 2" X 4" ROOF AREA: 2893.61 ft2 ATTACHMENT CITY: 53 AFTER/TOP CHORD SPACING: 24" PERCENT OF ROOF COVERED: 13% SPLICE QTY: 11 ATTACHMENT SPACING: 24" ARRAY WEIGHT: MODULE COUNT * 64.2 Ibs = 963.00 Ibs MIDCLAMP CITY: 30 POINT LOAD: ARRAY LBS/ATTACHMENTS = 18.17 ENDCLAMP CITY: 21 DISTRIBUTED LOAD: (Ibs/ft') (ARRAY) WEIGHT/AREA = 2.6 Ibs/ft 2 y ■ ■ T �,� to Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION JULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.24 kW AC / 5.24 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (15) HANWHA Q.PEAK DUO XL-G10.D/BFG 480 PV Modules (15) ENPHASE IQ8A-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY WSTI[ICT • ,t E • W GOB s N ' �0 20111163 tV`� �QISTERQO �SIO Af A L Signed 9/07/2023 J DRAWN BY: D.SANCHEZ DATE: 9/5/2023 MOUNTING DETAIL - PV04 HANWHA Q.PEAK DUO XL-G10.D/BFG 480 Specs POWER MAX (PMAX): 48OW OPEN CIRCUIT VOLTAGE (VOC): 53.39V MAX POWER -POINT CURRENT (IMP): 10.59A MAX POWER -POINT VOLTAGE (VMP): 45.33V SHORT CIRCUIT CURRENT (ISC): 11.12A SERIES FUSE RATING: 20A STRING (1): 20.OA ENPHASE : IQ8A-72-2-US (240V) Specs MAX INPUT VOLTAGE: 480 V MAX INPUT CURRENT: 20 A NOMINAL DC INPUT VOLTAGE: 400 V MAXIMUM OUTPUT POWER: 349 W NOM. OUTPUT VOLTAGE: 240 V MAX OUTPUT CURRENT: 1.45 A 1-Phase, 60 HZ, UL 1741 Listed 690.12 RAPID SHUTDOWN COMPLIANT Equipment Schedule TYPE: QTY: DESCRIPTION: RATING: MODULES: (15) HANWHA Q.PEAK DUO XL-G10.D/BFG 480 480 W INVERTERS: (15) ENPHASE IQ8A-72-2-US (240V) 349 W AC DISCONNECTS: (1) PV AC Disconnect, 240V, 2-Pole With 30A Fuses 60 A COMBINER BOX: (1) ENPHASE COMBINER 4 125 A 8 MODULES = I = I - �I L- - - - - - - - - J-BOX I STRING (2): 20.OA 1 2 I I I 7 MODULES = I = I = I I I I J-BOX J-BOX (N)240V/125A PV ENPHASE PV LOAD CENTER, AC COMBINER WITH INTEGRATED MONITORING, NEMA 3R RATED ENVOY -IQ MONITOR 2P-15A T T Conduit & Conductor Schedule TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SIZE (2) 12 AWG (90°C) Q-CABLE , COPPER (L1, L2) 1 (1) 12 AWG (90-C) THWN-2 COPPER - (GROUND) N/A - FREE AIR 2 (2) 10 AWG (90-C) THHN/THWN-2, COPPER - (LI, L2) 3/4" PVC (1) 10AWG (90-C) THWN-2COPPER -(GROUND) 3 (4) 10 AWG (90°C) THHN/THWN-2, COPPER - (L1, L2) 3/4" PVC (1) 10AWG (90-C) THWN-2COPPER -(GROUND) (3) 10 AWG (90°C) THHN/THWN-2, COPPER - (LI, L2, NEUTRAL) 4 (1) 10AWG (90-C) THWN-2COPPER -(GROUND) 3/4" PVC (3) 6 AWG (75-C) THHN/THWN-2, COPPER - (LI, L2, NEUTRAL) 5 (1) 6AWG (75-C) THWN-2COPPER -(GROUND) 3/4" PVC PV AC DISCONNECT 60A VISIBLE, LOCKABLE, LABELED, OPEN 240V, 2-POLE WITH 30A FUSES 2P-20A N I 2P-20A I " 4 - - -EGND} - - CONNECTION AS A LINE/SUPPLY SIDE CONNECTION - NEC 705.11(A) (E) 100A MAIN SERVICE PANEL (E) 100A-2 (E) LOADS (E) LOADS N r tLTJ (E) GROUNDING ELECTRODE LINE SIDE TAP USING INSULATION PEIRCING 705.11(A) I I I 120/240 VAC TO UTILITY GRID (E) UTILITY METER VISIBLE, LOCKABLE LABELED AC DISCONN LOCATED WITHIN 1 OF UTILITY METE ffV9iff9* 5 L A R Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION JULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.24 kW AC / 5.24 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (15) HANWHA Q.PEAK DUO XL-G10.D/BFG 480 PV Modules (15) ENPHASE IQ8A-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ ECT DATE: 01 9/5/2023 R LINE DIAGRAM - PV05 STRING CALCULATIONS ENPHASE : IQ8A-72-2-US (240V) STRING #1 STRING #2 MAX AC CURRENT 14A 14A MICRO INVERTER(S) IN SERIES: 8 7 NOMINAL VOLTAGE / RANGE 211V - 264V 211V - 264V MAX AC OUTPUT POWER: 2618W 2618W ARRAY DC POWER: 720OW TOTAL MAX AC CURRENT: 21.81A NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES 4-6 .80 7-9 .70 10-20 .50 SYSTEM OCPD CALCULATIONS INVERTER MODEL(S): ENPHASE IQ8A-72-2-US (240V) # OF INVERTER(S): 15 MAX OUTPUT CURRENT: 1.45A (# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING (15 X 1.45A X 1.25) = 27.27A <= 30A, OK PV LOAD CALCULATIONS: SUPPLY SIDE TIE-IN FEEDER WIRE RATING: 100A ALLOWABLE SOLAR CALCULATION (FEEDER RATING - 1.25) 80.00o0A (FEEDER WIRES ALLOWABLE SOLAR) 80.00o0A (AVAILABLE FOR PV) Conduit & Conductor Schedule TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SIZE CONDUCTOR RATING CONDUCTOR TEMP. RATE AMBIENTTEMP TEMP. DERATE # OF CONDUCTORS DERATE CONDUCTOR RATING W/DERATES CONDUIT FILL 1 (2) 12 AWG Q-CABLE , COPPER (L1, L2) N/A - FREE AIR 30A 900C 260C 1.0 N/A - FREE AIR 30.OA N/A - FREE AIR (1) 12 AWG THWN-2 COPPER- (GROUND) 2 (2) 12 AWG THHN/THWN-2, COPPER - (L1, L2) 3/4" PVC 40A 90°C 26°C 1.0 1.0 40.OA 12.03% (1) 12 AWG THWN-2 COPPER - (GROUND) 3 (4) 12 AWG THHN/THWN-2, COPPER - (L1, L2) 3/4" PVC 40A 90°C 26°C 1.0 0.8 32.OA 20.05% (1) 12 AWG THWN-2 COPPER - (GROUND) 4 (3) 10 AWG THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) 3/4" PVC 40A 90°C 26°C 1.0 1.0 40.OA 16.04% (1) 10 AWG THWN-2 COPPER - (GROUND) 5 (3) 6 AWG THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) 3/4" PVC 65A 75°C 26°C 1.0 1.0 65.OA 38.37% (1) 6 AWG THWN-2 COPPER - (GROUND) GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE. 2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.64]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5] 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH S L A R Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION 1ULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.24 kW AC / 5.24 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (15) HANWHA Q.PEAK DUO XL-G10.D/BFG 480 PV Modules (15) ENPHASE IQ8A-72-2-US (240V) Inverter(s) LSNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ DATE: 9/5/2023 ELECTRICAL CALCS - PV06 ! WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION A WARNING THIS EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. A.! WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER CURRENT DEVICE i WARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABEL 1 WHERE ALL TERMINALS OF THE DISCONNECTINGS MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS. [NEC 690.13(B) AND NEC 690.15(C) ] LABEL 2 PERMANENT WARNING LABELS SHALL BE APPLIED TO DISTRIBUTION EQUIPMENT. [NEC 705.12 (B) (3) (3)] LABEL 3 A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK -FED BREAKER FROM THEINVERTER. [NEC 705.12 (B) (3) (2)] LABEL 4 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES [NEC 705.101 LABELS ALL INTERACTIVE SYSTEM(S) POINTS OF INTERCONNECTION WITH OTHER SOURCES SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT THE DISCONNECTING MEANS AS A POWER SOURCE AND WITH THE RATED AC OUTPUT CURRENT AND THE NOMINAL OPERATING AC VOLTAGE. [NEC 690.541 (1) BUILDINGS WITH MORE THAN ONE RAPID SHUTDOWN TYPE. FOR BUILDINGS THAT HAVE PV SYSTEMS WITH BOTH RAPID SHUTDOWN TYPES OR A PV SYSTEM WITH A RAPID SHUTDOWN TYPE AND A PV SYSTEM WITH NO RAPID SHUTDOWN, A DETAILED PLAN VIEW DIAGRAM OF THE ROOF SHALL BE PROVIDED SHOWING EACH DIFFERENT PV SYSTEM AND A DOTTED LINE AROUND AREAS THAT REMAIN ENERGIZED AFTER THE RAPID SHUTDOWN SWITCH IS OPERATED. I ARFI INC; NCITFC- 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.11 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN sDLARELEcrRic SWICH TO THE "OFF" PAP"NEL6 POSITION TO SHUT DOWN PV SYSTEM AND REDUCE L SHOCK HAZARD IN ARRAY il— TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT MAIN SERVICE PANEL O O 0100 O (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) LABEL 6 AT DIRECT -CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 7 LABEL 10 BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. THE LABEL SHALL INCLUDE A SIMPLE DIAGRAM OF A BUILDING WITH A ROOF AND SHALL INCLUDE THE FOLLOWING WORDS: THE TITLE "SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN" SHALL UTILIZE CAPITALIZED CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN. IN BLACK ON YELLOW BACKGROUND, AND THE REMAINING CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16 IN. IN BLACK ON WHITE BACKGROUND. [NEC 690.56 (B), 690.4 (D) AND 705.101 LABEL 8 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56 (C) (1) (B)] LABEL 9 A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATED ON OR NO MORE THAN 3 FT FROM THE SWITCH THAT INCLUDES THIS WORDING. THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON RED BACKGROUND. [NEC 690.56 (C)] EXISTING SUB PANEL (IF WHERE POINT OF INTERCONNECTION IS MADE) 00 00 O (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) LABELING DIAGRAM: AC DISCONNECT 000 o� o PV COMBINER SUBPANEL- IF USED TO COMBINE PV OUTPUT CIRCUITS O O O O P H O T O V O L T A IC A C D I S C O N N E C T EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) POSITION AND BE PERMANENTLY MARKED: "PV SYSTEM DISCONNECT" OR EQUIVALENT. [NEC 690.13(B), 690.15 AND 705.201 INVERTER (S) 77DCI D000 0 INTEGRATED DC DISCONNECT JUNCTION BOX OR COMBINER BOX O n 06 *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. S L A R Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION 1ULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.24 kW AC / 5.24 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (15) HANWHA Q.PEAK DUO XL-G10.D/BFG 480 PV Modules (15) ENPHASE IQ8A-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ DATE: 9/5/2023 LABELS - PV07 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: N COMBINER BOX �i AC DISCONNECT UTILITY METER MAIN DISTRIBUTION UTILITY DISCONNECT PV ARRAY 1044 DALEY ST, EDMONDS, WA 98020 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.101) Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION 1ULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.24 kW AC / 5.24 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (15) HANWHA Q.PEAK DUO XL-G10.D/BFG 480 PV Modules (15) ENPHASE IQ8A-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ DATE: 9/5/2023 PLACARD - PV08 SITE PHOTOS: Weslmmouse c = # � R► 22 89 �22� e 43 34� 43 T 43 132 I' K I L O W Ai T T H 0 U R S 2A — in 2 FLA2" a SINGLE-STATOP VIATTMOUR METER' TYPE M s.5570C24GJ6 FORM 00 OL 240, V 3W 60 HZ TA 30 h 7.2 W SNOHOL11SH 0 577 COUNTY 76 361 57 Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION JULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.24 kW AC / 5.24 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (15) HANWHA Q.PEAK DUO XL-G10.D/BFG 480 PV Modules (15) ENPHASE IQ8A-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ DATE: 9/5/2023 SITE PHOTOS - PV09 powered by � DUO THE IDEAL SOLUTION FOR: Ground -mounted AN solar power plants Engineered in Germany MECHANICAL SPECIFICATION Format 872in x 41.1in x 138in (including frame) (2216 mmx 1045mmx 35mm) woa.m, Weight 64.2lbs(29.1kg) "rr,aam.l asrimRma ns N°'miN Front Cover 0.08 in (2.0mm) thermally pre -stressed glass with anti -reflect ion technology Back Cover 0.08in(2.Omm)semi -tempered glass oRw Frame Anodized aluminum Cell 6 x 26 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98inx 1.26-2.36in x 0.59-0.71in (53101mm x 32-60 mm x 15-18 mm), IP67, with bypass diodes e s Cable 4mmxSolar cable; (+)z27.6in(700mm),( )a13.8in(350mm) ro�°Df9tw Connector St&ubliMC4-Ew2,HanwhaQCELLS HQC4,IP68 R.tmma IpT°asasmN °+mmml IOI°anm'u o,.rw°u,°rr • : ELECTRICAL CHARACTERISTICS POWER CLASS 475 480 485 490 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STCa AND BSTCa (POWER TOLERANCE +5W /-OW) Q BSTC' BSTC' BSTC' BSTC' Power at MPP' P_ [W] 475 519.6 480 525.0 485 530.5 490 536.0 TOP BRANDPV / E Short Circuit Current' Isc [A] 11.08 12.12 11.12 12.17 1.1.16 12.21 11.20 12.26 *a ' E Open Circuit Voltage' V_ M53.15 53.34 53.39 53.58 53.63 53.82 53.86 54.06 EUROPE ' E Current at MPP I_ [A] 10.55 11.54 10.59 11.58 10.63 11.63 10.67 11.67 021 Voltage at MPP VN� M 45.03 45.02 45.33 45.32 45.63 45.62 45.93 45.92 Q CELLS Efficiency' q [%] >-20.5 >-22A 2!20.7 >-22.7 >-20.9 >-22.9 2!212 >-23.1 Yie,u Security Bifaciality of P_ and 1. 70%t5%•B'il lty given for rear side irradiation on top of STC(front side)• According to IEC 60904-1-2 Measurement tolerances PN,= t3%: Is°. V_ t5%at STC:1000 W/mz; 'at BSTC:1000W/mz+qpx 135 W/m2, 4p- 70%x5%. 25x2°C, AM 1.5 according to IEC 60904-3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOV BIFACIAL ENERGY YIELD GAIN OF UP TO20% Power at MPP P_ [W] 357.6 361.4 365.1 368.9 Bifacial Q.ANTUM solar cells with xro gap cell layout make efficient use of light E Short Circuit Current 1� [A] 8.92 8.96 8.99 9.02 shining on the module rear -side for radically improved LCOE. Open Circuit Voltage V_ M 50.27 50.49 50.72 50.95 i Current at MPP I_ [A] 8.30 8.34 8.37 8.40 LOW ELECTRICITY GENERATION COSTS Voltage at MPP V_ M 43.06 43.35 43.63 43.92 Q.ANTUM DUO Z combines cutting edge cell separation and innovative 2800W/m2, NMOT, spectrum AM 1.5 wiring with Q.ANTUM Technology for higher yield per surface area, lower QCELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE BOS costs, higher power classes, and an efficiency rate of up to 21.4%. r =--T----- r-----r----------------r x` - °�� Atleast 98%ofromitalpower - iNwYzanbRmwnne.' 6 �wRraa.m....�.� during first year. Thereafter max. , r , INNOVATIVE ALL-WEATHER TECHNOLOGY ug` 0.45%degradationperyear.Atleast u2eP-------L ----- ' ' O Optimal yields, whatever the weather with 93.95%of least 84.9 pother nomiuptonal 10 E {� p Y _ Z o --------------- years. At least Sa.95%of nominal excellent low -light and temperature behavior. s= paver up to30years. ••---------------------;-----; R: O ti a I Al data within measurement tderanc- ENDURING HIGH PERFORMANCE ®p es. Full warranties in accordance with.1 the •0 ono be be an �� s»e Lon term eld securft with Anti LID and Anti PID Technology', 2 sales warranty terms ofthe Q CELLS 9- Yl y ogYl. o m.1 sales organisation of your respective RRnouNCEiw/m+] ` Hot -Spot Protect and Traceable Quality Tra.QTm. ° ao ^Qm a Y = country. EaRs Typical module performance under low irradiance conditions in comparisontoSTCoondtions(25°C,1000W/m2) FRAME FOR VERSATILE MOUNTING OPTIONS TEMPERATURE COEFFICIENTS High-tech aluminum alloy frame protects from damage, enables use of awide range of mounting structures and is certified regarding IEC Temperature Coefficient oft. a [%/K] +0.04 Temperature Coefficient ofV.,[%/K] -0.27 for high snow (5400Pa) and wind loads (2400Pa). Temperature coefficient of PN,R If [%/K] -0.34 Nominal Module Operating Temperature NMOT [*F] 108t5.4 (42t3-C) PROPERTIES FOR SYSTEM DESIGN O A RELIABLE INVESTMENT Double glass module design enables extended lifetime with12-year Maximum System Voltagevrs M 150o PVmoduleclassification Classll product warranty and improved 30-year performance warranty2. Maximum series Fuse Rating [A DC] 20 Fire Rating based on ANSI / UL 61730 TYPE 29° Max. Design Load, Push/Pull' [Ibs/ftj 75 (360OPa)/33 (160OPa) Permitted Module Temperature-40°Fupto+185°F Max. Test Load, Push/ bs/ftj 1135400Pa/502400Pa �APT test conditions accordingtolEC/TS62804-1:20]Smethod B(-1500V.168h)bdudngpost treatment � ( ) ( ) on Continuous Duty (-40°Cupto+85°C) according to IEC 61215-1-1 Ed. 2.0 (CD) 'See Installation Manual ' New Type is similar to Type 3 but with metallic frame See date sheet on rear for further information. QUALIFICATIONS AND CERTIFICATES r�/I//��y� PACKAGING INFORMATION UL Paten NE 9.89 .21 O r1/" 0 0 9 IEC 81215:2018.IEC 81730..2018, w`A Ib US. Potent No.9.993.215 v �•® ( vary, . O-0 MR liaiicl aoh pascen>: C°�°„„US ` E ® Horizontal 89.4in 43.1in 47.6in 1975lbs 20 20 29 cerereo"^P°c•°° °"'° o;,;"dio;;, packaging 2270mm 1095mm 1210mm 896kg pallets pallets modules Nota: Installation instructions mist be followed. Seethe installation and operating manual or contact our technical service department for further information on approved installation and Use of this product. CELLS Hanwho 0 CELLS Amedea Ina. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I TEL +1949748 59 961 EMAIL inquiry@us.gcels.com I WEB www.q-celh.us ENPHASE IQ8 Series Microinverters IQ8 Series Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super -fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Enphase 1 25 year limited warranty Part of the Enphase Energy System. IQ8 Series IQ8 Series Microinverters redefine reliability Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative Enphase IQ Gateway, and the Enphase App monitoring hours of power -on testing, enabling an industry - and analysis software. leading limited warranty of up to 25 years. Connect PV modules quickly and easily to I08 Series IQ8 Series Microinverters are UL Listed as Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations. when installed according to manufacturer's instructions. © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8S E-DS-0001-01-EN-US-2022-03-17 Easy to install Lightweight and compact with plug-n-play connectors Power Line Communication (PLC) between components Faster installation with simple two -wire cabling High productivity and reliability Produce power even when the grid is down* More than one million cumulative hours of testing Class II double -insulated enclosure Optimized for the latest high- powered PV modules Microgrid-forming Complies with the latest advanced grid support** Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 21(UL 1741-SA) requirements • Only when installed with IQ System Controller 2, meets UL 1741. IQ8H-208V operates only in grid -tied mode. IQ8 Series Microinverters supports split phase, 240V. IQ8H-208 supports split phase. 208V only. Commonly used module pairingsz w 235 - 350 235 - 440 260 - 460 295 - 500 320 - 540+ 295 - 500, Module compatibility 60-cell/120 half -cell 60-cell/120 half -cell, 66-cell/132 half -cell and 72-cell/144 half -cell MPPT voltage range V 27 - 37 29 - 45 33 - 45 36 - 45 38 - 45 38 - 45 Operating range V 25 - 48 25 - 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max DC current' [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration OUTPUT DATA 1x1 Ungrounded array: No additional DC side protection required; AC side protection requires max 20A per branch circuit 1: 1:' 1: 1: 1: 1IQBH-208-72-21 Peak output power VA ,I 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal (L-L) voltage/range' V 240 / 211- 264 208 / 183 - 250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50 - 68 AC short circuit fault current over 2 4.4 3 cycles Arms Max units per 20 A (L-L) branch circuit' 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85 leading - 0.85 lagging Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency % 97 97 97 97.5 97 97 Night-time power consumption MECHANICAL DATA raw 60 Ambient temperature range -40°C to +60*C (-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions (HxWxD) 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") Weight 1.08 kg (2.381bs) Cooling Natural convection - no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class 11 double -insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor CA Rule 21(UL 1741-SA)• UL 62109-1• UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer's instructions. (1) The I081-1-208 variant will be operating in grid -tied mode only at 208V AC. (2) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/module-compatibility (3) Maximum continuous input DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-17 Enphase 10 Combiner 4/4C Enphase IQ Combiner 414C AQ_1rv111f I—L`�i 0-4 —�Q'—A M 1-240-4 The Enphase IQ Combiner 414C with Enphase IQ Gateway and integrated LTE-Ml cell modern (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ rnicroinverters and storage installations by providing aconsistent, pyre -wired soluticin for residential aaplicaticris. It offers up to four 2-pole input circults and Eaton BIR series hushar assembly. Smart • Includes IQ Gate -Hay or commun-cation and Control • Includen Enphase NI InbileCon nest. ne lular modem CELL MOD EM-M1-06-SP-05)• indudle€i onlyr with IQ CDmbiner 4C • includes solar shield to match Enphase IQ Battery aesthetics and deflect heat Flexible networking supports hrdi-Fi. Ethernet, or Cellular • Optional AC receptacle available for PLC bridge • Provides production metering and consumption morkaring Silmpl e • Centered mount`ng bra: kets support single stud mount-ng • Supports bottom. back and side oanduit entry Up to Four 2-pole branch circuits for 240. VAC plulg-in breakers (not includ4 00A, tctal PV or storage branch circuits I Reliable Durable NRTL-certified NEI IA type 3R encilosure Five-year limited warranty • Two years labor reimbursement program coverage included 'or both the IQ Combiner SKLI's MODEL NUMBER IQ Combiner 4 (X-1Q-AU1-20-4) IQ Cambiner4wIth Enphase IQ GairmW pdnud abmlt bowd kw lmugrztcd m-mnue trade; Pity' pnxLctmn meUring (ANSI C12.20 +".5%) and ccnsumpdon mamitariV (+rr- 2.5). lncL ho a siver sal m shield W match the 1,0 Bsattair. sxsuern and IQSystiemCorruolkr 2 and to deflect heat. IQ Combiner 4C (Y-I0-AM11-240-4C) IQCembIner 4C wlth Erithase IQ^3altwa prlrned clrcuitboard kar Integrated revenue riadePr+prDd _1Ldon niter ng (ANSIC1220 }1-0.5%) and consumption monitoring {+F-2.S95). Includes Enphase MobileCameci re 'ular modem (CELLMODEI l-W1-06-&P-65), a plug -and -play industrial -grade Dell modem 9oa systems up is 60 microinverters. (Available in the US, Canada, Mexico, PoJertD Rico, and the LFS''Virgn Islands, where there is adequate calkilse service in the Installation area.) Includes a silYer sokrshiekf to match the iD Banery and IQ system Conrialler and to deflecl heat. ACCESSORIES AND REPLACEMENT PARTS (not included. order separately;l EnsembleCDmmunicatlonsKit -includes COMMS-IUT-01and CIFUNI DEk1-1'l-O&SP-05with5-yearSprintdataplanfar COMMS-CELLMOD;EM-Mi-06 Ensemble sites CELLNIODE#dA41-06-SP-05 4G based LTE-kit cellular modem with 5yrcar Sprint data plan CEL.LMODEii l-D6-AT 05 4G based LTE-kit cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210, BR215, BR22D, SR230, QR240, BR250, and BR260 circuit breakers. BRK-IDA-2-24D+V Clrcue brLaker, 2 pok,10A, Eaton 8R210 BRK-15A,-2-240V Clrcuii brLaker, 2 pok,1SA. Eaton 8 R21 5 BRK-20A-215-24DV Clrcuit brLaker, 2 pok, 20A,Eaton BR220 BRK-15A-213-240V-E Clrc u e breaker, 2 pole. 15A., Eason B R2158 with hold down kit support BRK-20A-7P-240V-8 CI¢ u it breaker, 2 pole, 20A.Eaton GR2:208 with hold down kitsuppart EPL a-01 Power line carrier (communication bridge pair), quanllty - one psi' XA-a4LARSHIELD-ES Replacement solar shield for IQ Combiner 44C %.4-PLUG-124-8 Accessory receptacle for Pvweir Una Carrier In IQ Combiner 414C (required for EPLC-D1) XA-E4V-PC8A.-3 Replacement IQ Gateway printed circuit board (P''B) Far C-amb!rier 414C X-IQ- NA-RD-125A lipid down kit for Eaton r%di breaker with screws. ELECTRICAL SPECIFICATIONS Rating System rallage Eaton BR series bulbar ratng Max. ccmiruaus carer, rating Max- continuous current ra" (input from PVjatarage) Maer. fusercircultrating (Ditpui) Branch c rcuAs (saint andfar 5wrage) Mm. [vial Imanch circuit breaker rating (Input) PrDductlon meurirg CT Garnil duty 12Df240 VACS dD 1♦z 125 As 65 A 64 A 4 D A, up to four 2-pole Entan DR series Dlstrllwtsd Generaticn (DG) breakers only (not Included) BOA al cilstrlbuied generation r' g5A with It; "gateway breaker included 200 A solid care pre -Installed end wired to IQ Gateway Consumption monitoring CT (CT-20D-SPLIT) A par of 200 A spilt core current bansFcemem MECHANICAL DATA Dlmenslons (WaWxD) 37.5x 49.5 x 16.e enu(14:75• c i9.5' x 6.63'j. I3alght is 21.06';53.5 cmi widi mounting brackets. We rght 7.5kg (16.5 bs) Amblent temperature range -409 C So+490 C (40Q to 115Q F� Cooling Natural cDnvectian, plus heat shle Id Enclosureern-iranmental rating Duldoor, NRTL-certified, NE"type 2R, paiycarbonate construction Wire sizes • 20 A to 50 A breaker Inputs: 14 to 4 AWG capper conductors • 60A breaker branch input:410 110 AWG copper conductorz Un n lug cambned output: 10 to 2f0 AWG copper conductors Neutral and ground: 141a 110 capper canckimrs A -.Ways follow IDcal code requiementsfor conductor sizing.. AIIJUAW To 2000 meters (6.560 feet) INTERNET (CONNECTION OPTIONS Integrated WI-FI 602-111SAWn Cellular CELLMDDEM-MI-06-SP-05,CELL.MODEk4-MI-06-AT-05(4GbasedLTE-41 cellular modern). Note*natanEm ase Mehlk (need cellular modem is required for all Ensemble Installations. Ethernet Opllonal, 902.0, CatSE (or Cat 6) LITP Ethernet cable (mot included) COMPLIANCE C impliance, IQ Combiner u L 1741, C kNl CSA C22.2 No. 107.11. 47 CFR; Part 15w Ciaas 4, IC LG 003 Production mewrinq: ANSI C12.2D accuracy class h 5 (PV producllan) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway uL 60601.1/CANCSA22.2 No. 61,310-1 USTE8 To le.ar;� mc.ne about Enphase offerirvg, vrisd eapha e.coni ENIPHASE To learn more ab iLd Enphase offerings, visit enphase.co E N P H E- E- 2021 en:rhase Enery-j. Al righls rt:=-ved. u.nrha:x, the Cn�fuue k,rp. IQ CL-mire- 44C, ant: ulhei rlarrCs a: a I adw r s hs ul Er:d-ar& Energy: Inc. Data suaject le charr4e. '10-21-2021 RT-MINI II is suitable for all systems with any L-Foot Conduit Strap Installation RT Serrated Hex Flange Bolt/Nut: 5/16-18 x 1" 4No Caulking or Pre -Drilling Required Universal Attachment to Any Slope Metal, EPDIVI, TPO, SBS, & Asphalt Roofs Wide Range of Applications & Ultimate Flexibility on the Roof 4No Need to Bend Rails 1 5/8 North & South Adjustment o- ICC `'ar -4 _ Installation Manual ICC ESR 3575 Components RT2-00-M I N I B K2 MINI II base : 20 ea. O$�2 Screw: 40 ea. Extra RT-Butyl : 4 ea. Optional Items: 5 x 60mm Mounting Screw (RT2-04-SD5-60) : 100 ea./Bag 5/16 X 25MM Flange Bolt & Nut (RT2-04-FBN25) : 100 ea./Bag RT-Butyl (RT2-04-MNBUTYL) : 10 ea./Box Deck Installation Rafter Installation OSB & PLY Hybrid Mounting 1 , Roof Tech Inc. AlphaSealTm Technology has been used on over one million residential PV systems since 1994. It is the first PV mounting system with Flexible Flashing certified by the ICC, engineered to withstand wind speeds up to 180 mph and ground snow up to 90 psf. Engineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood) ICC ESR-3575 ASTM2140 Testing P. E. Letters a 0 tea#; Support & Downloads T ❑ 1� Dimensions in (mm) o I r- ' .......... _....... -.............. 0 o O .� ....... _...... r.. .E" m O o 3.54 inch (90mm) .60 inch (15.4mm) Offset Rafter Installation Offset Rafter Attachment Options Metal Flashing Retrofit Flexible Flashing 100% Waterproof CHIKQUSA RACKING MADE SIMPLE Classic Rail #7 Rail & Splice Kit Mid Clamp & End Clamp rT Mid clamp: • 30/33/35/38/40/45/50mm -......................-...........................-.-...................-.-...-.............................................................................................................................. Black mid clamp: IT 30/33/35/38/40/45/50mm VlfI-f Adjustable mid clamp 30/35/40/45/50mm Thin Film Mid Clamp *e4" 5.6-7.3mm 23 End clamp: 30/33/35/38/40/45/50mm 444 Black end clamp: 30/33/35/38/40/45/50mm t% S1 Z Adjustable end clamp: 35/40/45/50mm 40, a Thin Film End Clamp 5.5-7.3mm Infit Rail & Splice Kit Mid Clamq & End Clam Mid clamp 30/33/35/38/40/45/50mm CHIKQUSA RACKING MADE SIMPLE End Clamp 30/33/35/38/40/45/50mm /�'►"'' Adjustable Mid Clamp I �# Adjustable End Clamp 33-45mm 30-45mm ---------------- -� Thin Film Mid Clamp Thin Film End Clamp 5.6-7.3mm I 5.5-7.3mm i 10