APPROVED FIR2022-0117+Fire_Sprinkler_Plan+12.5.2022_3.28.33_PM+32529274/12 PITCH 24" CARDBOARD BAFFLE ALLOW FOR 1" AIR SPACE MIN. EXTEND 12" ABOVE IN5ULATION 501-I1) SHEATHING OR CDX PLYWD WHERE EXPOSED TO WEATHER 1X FA5CIA DD. W/ METAL GUTTER 2X BIRD BLK'G W/ ' 2" 5CREENED VENT HOLE5 WITH 1/4'' CORRP51ON RE515TANT METAL MESH COVERING FIN. FLR. TOP PL. FIN. FLR. TOP FL. 2X STUDS @ 16" O.C. TYP SIDING, 5EE PLAN5 FIN. GRADE TO SLOPE - AWAY FROM BUILDING Z _4; e - ALARM VALVE RISER A -FLOW SWTICH RISER O - DRY PIPE RISER - DELUGE/P.A. RISER - FIRE DEPARTMENT CONNECTION .6. - WATER MOTOR GONG 0 - ELECTRIC BELL Blown -in EDinsulation 1, R-21 1 LIVING AREA 1/2" GYPSUM WALLBOARD, TYP W/PVA VAPOR BARRIER @ WALL AND CELING5 ENGINEERED J015T5,51ZE AND 5PACING PER PLAN OR 2X J015T 1/2" GYPSUM WALLBOARD, TYP W/PVA VAPOR BARRIER @ WALL AND CELING5 LIVING AREA ENGINEERED J015T5,51ZE AND 5PACING PER PLAN OR 2X J015T 1/2" GYP5UM WALLBOARD, TYP W/PVA VAPOR BARRIER @ WALL AND CELING5 FIRE BLOCK ALL VERTICAL OPENING5 IN WALL5 AT PLATE5 AND FLOOR5 LIVING AREA 2X BOTTOM PLATE 2X F.T. SILL ANCHOR BOLT PER PLAN R-10 INSULATION 4" CONC. SLAB ON @ 24" PERIMETER 4" GRANULAR BED r . . t . a ` ALL REINFORCMENT MU5T DE TIED IN PLACE FOR FOUNDATION IN5PECTION L 5EE FDN PLAN FOR FTG. /FDN 51ZE ALL FOOTING TO DEAR ON DEARING 501L Unheated attic space Tent' space keeping Insulation above piping Heated space \ u u.0 trtLOW RIM M2" ROUND CONC W/ '4'��INVERTED NAIL SDMH11, STA:30+00.44-10.48 SEE WATER RIM.345.50 _ *ENTRANCE C3 0 SERVICE LINE_ _ IE 340.42-(12"PVC IN, S� SEE FRONTAGE" M DETAIL - D ss X. STOP BAR Q C p ° _ i J? 12' 12 72 MIN 96 e � I H RIM 37 1 I 11.9 24 0AYT I 1 2 i • FA Iowan 111111INKIN, F Ift � I \ / D ATH/BIKE ems,?o 4 CB#2 N . EX. C. B 350.04 EX. TOP ' CB#3 TOP=349.58 V= 348 B9 "W SIGN TBR) CONCRETE EXTR ED 351.75 CURB PER CITY F A EDMONDS TR-52 (TYP) 6 i 36 EX. INGRESS, EG SS I I \ 'o, N EASEMENT A.F. N 7801230217 ° 18 us -- � x Z I , x I I x 352. SO 65.00' I x I I I N 86 0'49" WUAT ' � I EX. 6" TO I FH TEE I " I x 6 IIT I 17 �S�S O x I �w, I 353 00 1 °c I I x „I BLD D 32 x �,� , 8 I , x "I UNIT 16 I I o II I/ 10' 353.2 ' I— � I UNTT Is 30 N 50 _ A.F. '? 9\ 010�'50J90 UNIT 23.25�_ B D A UATT3 7 ` h \ °j 5 °° 4 lr)' — 7 00 17,s- \ `" ROOF ORAIN 02%MIN\ 25' �s1 \ \ \' �s Dl. FH I 9" 3S42S CB RIM 349.81 DRAWING SYMBOLS HYDRAULIC DESIGN INFO. F $ $ - - I - FLEXIBLE GROOVED COUPLING - RIGID GROOVED COUPLING - THREADED PIPE COUPLING - CONTROL VALVE -CHECK VALVE -PIPE HANGER (SEE CHART) - PIPE HANGER (SEE CHART) A-1 - WELDED PIPE TAG O - BRANCHLINE NUMBER 9-0 -PIPE SIZE &LENGTH ($10) - PIPE SIZE & LENGTH(CUT) too - HYDRAULIC NODE 10'-0" AFF U 10 BOD- -ELEVATION DATUM —� - CENTERLINE OF PIPE TO DECK rJ( THIS SYSTEM IS THIS SYSTEM IS NOT LLJJ HYDRAULICALLY DESIGNED HYDRAULICALLY DESIGNED FLOW TEST STATIC xx gZ_ RESIDUAL xx GPM FLOWING xx DATE & TIME xx A/CVIeW SYSTEM DESIGi, REMOTE AREA xx DENSITY xx MAX. AREA/HEAD xx K-FACTOR xx xx ,9 UNIl5 ' LD t5° I 13 U1V177 15 SIT 8 it 17 x / \ 28 / x s 27 EX. C. B RIM=351.24 \ 1 \ I TOP=351.25 ` \ \ UNIT 14 x INV=349.01-6"W �\ I\ ` \ ��S o 19 UAgr10 1�x � \ N I/ �o \ C)�5�25 BL C ^� 0 555�° I Ln CB RIM 351. 4 21 i T \� \ 355.00 27033600100� DO 1 3 r EDMONDSWAY ILLC C3.� ENCLORE \ \ \ 9504 EDMONDS WAY EDMONDS, WA 9 Y3 / o - 4" YELLOW PERIMET R FIRE LA TRIPING (TO BE 0 FSET 6" FRO CURB OR EDGE OF PAVEMENT.) \\ \ " MIN LETTERING W/ 2" STROKE. /x - rev COE TR-567 \ ° a 25 p�X CONCRETE EXTRUDED t/N1T13 CUB PER CITY OF z \ ED ONDS TR-522 (TYP) x a� 5� �56 A° \ 0 7„ I 10, 15 \ I BSB/ I I I I HANGER LEGEND 10, S/TE �'L.9i✓ l INV=341.14 MH 15-769 \ TOP=+/-348 JJ � Ss FND 1 2 A W/CA L \\ o \\ r--� I � \ CBMH TOP=351.44 INV=345.14-36" INV=344.74- 12 "NW 0. F.=349.54 EX. S. S. M. H. TOP=350.23 INV=343.99 1 �J CB#4 ONE CARTRIDGE STORM FILTER "4" Footing drain @ 0.5%; ;Install one-way flow valve L 0 T 1 6 27033600102200 TRIMARK-WESTGATE APARTMENTS LLC 22816 EDMONDS WAY EDMONDS, WA. 98020 HEAD LEGEND SPRINKLER TYPE MFG MODEL I SYMBOL 1ORIFICE1 FINISH CANOPY TEMP K-FAC OTY I I I TOTAL THIS SHEET i DENED HEX HEAD SE 1 FURNISHED WITH THI MINIMUM FASTENER "STAND-OFF" HANGER & RESTRAINER TOLCO FIG.28 HANGER TYPE CP SCALE: NITS I i DOUBLE FASTENER STRAP TYPE HANGER I TOLCO FIG.24 HANGER TYPE CP SCALE: WTS n z E ReAl ro 3/4°.yaSB' 4-4 C0ZV,0,,8h-9 SiA/?TS ffE247- 3ENED HEX HEAD SELF THREADING SCRI 'URNISHED WITH THE HANGER AND IS TH MINIMUM FASTENER SIZE ACCEPTABLE ,I. DOUBLE FASTENER STRAPTYPE HANG TOLCO FIG.23 HANGER TYPE CP SCALE:NTS P. /2 _V_ (13Y oTf/�Rs� Ski>c FF VA, �9TE �lt,cS�9LL lijg (O � of 7-Y I „ � „ /,4 Q c AP 7Ye, lz/-:SCR bET�9ZZ- tio 5 cALG Col�zmbia Fire OVA CL# COLUMFI952MG III S Findlay St Seattle, WA 98108 (206) 232-8569 PROJECT: Z Z 8/0 E,n�o vOS ` AR E'pM45_4 4-S lvi9, ggbZ o iCisA�v E�r/T�'2PR,G CONTRACT WITH: z 04,07 sT.97e- tr, 9sue, s1lz:w4 /rl/S,y� X X X X X X x X V,*,- 60 T Y 129AP Uj J ~ Q w 0- 0- DESIGNER: DATE: 6/5,zz RQY1Szb /z/z/2z SCALE: /4S it/oT�,b HAZARD: A1050,541/34 20/914-'p, AHJ: -5. KIAJG Cam• F"! 4ZS- 775- 77Z0 �yto JOB # ZZOS3oC� SHEET # /_ 2 j I _ 1 4 ei BLDG C - LEVEL1 - FLOOR PLAN SCALE: 1/8" = V-0" ® 5E R.C.-CIM #1 I P/Pr 9�ovc c�U /,4/sUL,977\I _ /NG,9R.f �14F_ �Wi9/Z/y1 S/ ' • , I J IN L I T6" 361-1/2" i i 1 5'4 2'41/2" 5'3-ill" -- 4'9-1 " ��ll ------------- �( nILL HEIGHT _ __--. �O - _ _ N 4 Al� I( o g�� DEDR OM 114 6� a ,36 i UNIT 13 N U1 f9 2640 2640 Z VAULTED AREA r A: i 51/2" 5'6" 5'6" 48" 2.9'. 29'- 4'b-1/2" 6.9., fl' 1'3" 141,0-1/2 X NLLT5. IMCGP'10A'' ER A.5_NT REST y:iu SE VEVTILAi1GN ' AIR INLETS. IMC a0.:.8b L'�IN:i JtHAUST SANS 8 FRESH >iR I!:L_'TS IMC W38.E GUIKEOIITDOOR AAINLETS "•"-•'."��"••,• "•. "•-. �.•••,•'••,'-- TIME IN EACH 'HOUR SEGMENT. ROOF MATERIAL PER STRUCTURAL ENGINEER 24"CARDBOARD BAFFLE ALLOW FOR 1" AIR SPACE MIN. EXTEND 12" ABOVE INSULATION SOLID SHEATHING OR CDT PLYWD WHERE EXPOSED i0 WEATHER IX FASCIA BD. W/ METAL GUTTER ZX BIRD BLK'G W/ 2' SCREENED VENT HOLES WITH 1/4' CORRPSION RESISTANT METAL MESH COVERING FM1. FLR. TOP PL. LIVING AREA 1/2" GYF5UM WALLBOARD, TYP. W/PVA VAPOR BARRIER 0 WALL AND CELING5 ENGINEERED J015T5,52E AND SPACING PER PLAN OR 2X J015T 1/2" GYP5UM WALLBOARD. TTP. W/PVA VAPOR BARRIER 0 WALL AND CEILINGS LIVING AREA 4n2 PITCH ENGINEERED J015TS,51ZE AND SPACING PER PLAN OR 2X J015T FIN. FLR. - -- -- -- - - TOP, BLDG C - LEVEL3 - FLOOR PLAN \-I/2"GYP5UM WALLBOARD, TYP. W/PVA VAPOR BARRIER 0 WALL AND CELING5 SCALE: 1/8" =1'-O" FIRE BLOCK ALL VERTICAL OPENINGS IN WALLS AT PLATES AND FLOORS ACTUAL HT: 387.19' ACTUAL HT: 387.1 LIVING AREA 7Jf STUDS O 16" O.C. TYP. SIDING, SEE PLANS 2T BOTTOM "iE 2X P.i. SILL NCHOK BOLT PER PLAN — _ R- 10N 4" CONE. 5LA6 ON 101 - - — ®24"FERIMPERIMETER 4" GRANULAR BED FIN. GRADE TO SLOPE - AWAY FROM BUILDING INFORCMENT MUST BE TIED IN FIFDN FOR FOUNDATION INSPECTION FOR BEAR ON - - BEARING 501L TYPICAL GRO55 SECTION SECTION VIEW SCALE, NTS _ I - I I I I I 369-1/2" 71/2'--- 3'3" 3'3" 53" 122" 3D6D 30- 3060 w 3060 l I r X - GREAT ROOM -:iON BOWS By KOHLER (FAUCET) 1'10' Tyr. FO ALL KL-CP IA GPM TYR FOR ALL UNMS WSEC CREDIT Ba (5 —AW) �ROHE 261T700 FAIRBORN SHOWER HEAD 1.75 GPM TYR.. FOPR ALL UNITS 4' i y..�� BEDRJUM *rL fj A 2'8-1/2" '11Z' 5'2-/2" 2'4-1/2" 1'2" 1---- 8'9" IT 1'3" BLDG C - LEVEL2 - FLOOR PLAN SCALE: 1/8" = V-0" /,j0-ST A/YZIZIg4 L /c,614L Y &:97,IWO7E h�e,,9,65 S?REE%- z /lE,gA f z 6 7. 7 72" DIN o IT PER 20 fi f1+N i V P a X x X X X X x x BLDG C - ELEVATION VIEW 1 4t J W — SCALE: 1/8" = 1'-0" c) � of! Q W C_ (I - DRAWING SYMBOLS HYDRAULIC DESIGN INFO. HANGER LEGEND HEAD LEGEND PROJECT: �yt� '/ 'J /\ DESIGNER: F THIS SYSTEM IS THIS SYSTEM IS NOT /sITN T��f�/ /%Q• s �L U � i / U w /�T /� e - ALARM VALVE RISER -� - FLEXIBLE GROOVED COUPLING A 1 - WELDED PIPE TAG HYDRAULICALLY DESIGNED ❑ HYDRAULICALLY DESIGNED SPRINKLER TYPE MFG MODEL SYMBOL ORIFICE FINISH CANOPY TEMP K-FAC OTY v /� DATE: ,QE I//SEA FLOW TEST co vc'�/�G�d PE�1JL1��/T v/k/r✓C� �K4 94 • /z �.s'%T�' ro,✓c, /s's 4, i /% Z Z $/D E�/f%O�✓,l�S uJi9 y / z/3/zz A -FLOW SWTICH RISER $ - RIGID GROOVED COUPLING O9 - BRANCHLINE NUMBER STATIC xx •, Aj �i • i� �' i/ �� ii 0 SCALE: � v / /" 1 RESIDUAL xx �Lvi/O/✓�.5� LCJ/4. 98oz,0 O - DRY PIPE RISER - THREADED PIP' COUPLING 9 0 - PIPE SIZE & LENGTH GPM FLOWING xx 1 DATE & TIME xx HAZARD: o - DELUGE/P.A. RISER - CONTROL VALVE - PIPE SIZE & LENGTH(CUT) CONTRACT WITH: (8 10) SYSTEM DESIGN (�9/ 1�9N/�Sc,9B/Nli GO�vST AHJ: - FIRE DEPARTMENT CONNECTION -�- - CHECK VALVE 00 - HYDRAULIC NODE REMOTE AREA xx Columbia -Fire O � 10'-0"AFF DENSITY xx T- yWA C'L# COLUMFI952MG JOB # ZZOS.30Q - WATER MOTOR GONG �- -PIPE HANGER (SEE CHART) 0'-10" BOD -ELEVATION DATUM MAX. AREA/HEAD xx GZZ� 111 S Findlay St K-FACTOR xx Seattle, WA 98108 SHEET # Z_ Z - ELECTRIC BELL -�- f -PIPE HANGER (SEE CHART) -CENTERLINE OF PIPE TO DECK xx / ,-goA .41-44, C TOTAL THIS SHEET /7 (206)232-8569 /�ENp2,q L. 9zs-goZ— 99ov