Loading...
APPROVED BLD PLN BLD2023-1067+Site_Plan+8.28.2023_12.39.19_AM+3749634TE�HO -ll8-4I SIRE I WAILK Mt1A+K I I I S880,3.5' 18 "E D FENCE I I , 1 _ R00 E LINE City Of Edmonds Building Department Work MECHANICAL- GENERATOR Address 1400 9TH AVE. NORTH Owner GETACHEW Approved Date . 9/01/2023 Building Official - ------------------------- Permit Number BLD2023-1067 -------------------------------------------------------- 130. 00.1 The Following Documents and Plans to be on Site at Time of Inspection: 1. Manufacturer Installation Requirements 2. Site Plan Showing the Height and Setback of the Mechanical Unit 3. L & I Electrical Permit and Inspection to be Completed at time of City Inspection ALL WORK SUBJECT OBTAIN ELECTRICAL TO FIELD PERMIT FROM INSPECTION FOR STATE LABOR & CODE COMPLIANCE INDUSTRIES I v I ON I I c I G i 99 2 S88b3518 "E -7 190. IN L z- 5o E/ CHAIN'LINK FENCE/ , 9 P1=96.5 '' 10' BUILDIN� SETBACK _ T�� --------------- I 1 c 0) �� I z Io �o 1 �NC/-) L�� I I I � � I I 111 'ED I 0 iw ' I � II I I � � -------------L--- C = 9 61 5 25' BU LDING SETBACK * J I I I _ S88-35'18"_ 0.00' PROPERTY LINES - I 9.50' I I I I o� I �\ C -k . . ......... -7---7 CHAIN The following documentation shall be available on site for the building inspector: ; ■ ; COE APPROVED ARCHITECTURAL PLAN SET - ■ ; ❑ COE APPROVED STRUCTURAL PLAN SET : []COE REVIEWED CALCULATION PACKET ' ■ ENERGY CREDIT WORKSHEET ■ ❑X SITE PLAN ; CIVIL PLAN ■ Manufacture Spec . and installation ■o ' CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■ PROJECT DATA PROPERTY OWNERS: GENET SOLOMON & DESTA GETACHEW 20204 37TH AVE W LYNNWOOD, WA 98036 (206) 954-4145 PROJECT CONTACT: KIM HELLEREN LEIF HELLEREN CONSTRUCTION, INC. PO BOX 1764 EDMONDS, WA 98020 (206) 533-8200 nordicgol1 @comcast.net CONTRACTOR: LEIF HELLEREN CONSTRUCTION, INC. ATTN: LEIF HELLEREN P.O. BOX 1764 EDMONDS, WA 98020 (206) 533-8200 STATE CONTRACTOR'S LICENSE: LEIFHC10380T SITE DATA SITE ADDRESS: 1400 9TH AVE S PARCEL NUMBER: 006083 000 002 01 TOTAL LOT AREA: 13,448 SF (0.31 AC) ZONING: RS-12 BUILDING SETBACK LINES (BSBL): STREET: 25 FEET SIDE: 10 FEET REAR. 25 FEET MAXIMUM BUILDING HEIGHT: 25' MAXIMUM COVERAGE: 35 PERCENT SCOPE OF WORK: INSTALL A GENERATOR. LEGAL DESCRIPTION LOT 2 OF CITY OF EDMONDS SHORT PLAT NO. PLN20190036, RECORDED UNDER AUDITOR'S FILE NUMBER 202108315004. SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHI NGTON. SCALE 1 " = 10' 0' 5' 10' 20' 30' APPROVED BY PLANNING Aug 29 2023 Noise generated by mechanical equipment must meet the standards in ECC 5.30 it Z o� �o RECEIVED 8/28/23 w v Z w C� O w N O �-- 03 � J Q Q LLJ �7 C , Z ZCVO O Q W wC-V V') = w w �Z> < < W = O Z O O O —i O DRAWN DATE: 08/24/2023 DRAWN BY: TL CHECKED BY: TL PROJECT NO. 201202 SHEET NAME SITE PLAN SHEET NUMBER AO I PRINT DATE: 07/31/2023 2ND FLOOR PLATE 113- 99" 2ND FLOO 104' - 7 7/8" MAIN FLOOR PLAT 103- 1 1 MAIN FLOOR 94'-0" FRONT (WEST) ELEVATION 1/4" = 1'-0" 2ND FLOOR PLATE III 9" -10 a 32 22 2ND FLOOR MAIN FLOOR PLATE 103-1-11/8" 16 4 ffi= 6' - 0" 3' 11" 11' - 71/2" 01 �GENERATOR LOCATION Mn 1 - I- I- -1 I I -I I I -I I I- - I I I -I I I -I I I -I I ELEVATION VIEWS u I -ICI �r MAIN FLOOR Ell I I - I -I -I I-1,.I - 1I I I I -I I I -I I I -I -I I I -I I I -I I I -I III I I -I 1 1-I I I -I I I -I I I -I I I -I I I -I I I -I I I -I I I -I I I -I I I -I I GENERATOR IS ATTACHED TO PRE -MANUFACTURED PAD w/ (6) 8" LAG SCREWS (OR PER MANUF. SPECS). PAD DIMENSIONS ARE 52" x 31". SUPPLIED BY MANUF. SOUTH ELEVATION 1/4" = 1'-0" n C B A EXHAUST AIR O OUTLET F / 0 a LU 0 I OUTSIDE UNIT GENERATOR DIMENSIONS (NTS) INLET NOTE: DIMENSIONS IN a ARE INCH EQUIVALENTS. c LO N UNLESS ALL DIMENSIONS IN MILLIMETERS DO NOT SCALE. GENERAXxX, LTOLERANCEs: 0.25 X.XX t x.x *1.0 SURFACE FINISH X * 1.5 ANGLES :O°30' MAX THIS ASSEMBLY OR PART MUST COMPLY WITH PEP-RML-001. REFERENCE CAD MODEL FOR CHANGE ON COMPOSITE owes, SEE PART NO. FOR REVISION LEVEL REV DATE NUMBER OINDICATESPARTNUMBERSAFFECTEDBYLATEST BY UNSPECIFIED DIMENSIONS. DRAWING REVISION 04NOV2020 CT207992 NEW DRAWING AZE THIRD ANGLE PROJECTION 16TR) EE] KOHLER. KOHLER WISCONSIN 53044 MAJOR O= 0 CRITICAL ® = 0 CHARACTE%P_%0S9MPLY WITH [ SCALE: NA SHEET SIZE: B SHEET 1 OF TITLE: DIMENSION PRINT, DRAWN AZE8800 BY DATE: 104NOV20201 14/18/20RCA 14/18/20RCA APPROVED KJB -....... A11\/_11117AA KOHLER. Models: 20RCA(L) Multi -Fuel LPG/Natural Gas 09001 Standard Features 4 KOHLER. • RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT). o Electronic speed control responds quickly to varying demand. o OnCueO Plus Generator Management System for remote monitoringis included with the generator. • Kohler Command PRO Engine Features o Kohler Command PRO@' OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. • Designed for Easy Installation The Kohler® Advantage o Sturdy aluminum base can be mounted on gravel or a concrete mounting pad. • High Quality Power c Fuel and electrical connections through the enclosure wall Kohler home generators provide advanced voltage and eliminate the need for stub -ups through the base. frequency regulation along with ultra -low levels of harmonic c Customer connection terminal block located near the distortion for excellent generator power quality to protect your controller allows easy access for field wiring. valuable electronics. o Designed for outdoor installation only. • Premium 5-yr/2000-hr Limited Warranty Included • Certifications Kohler is known for extraordinary reliability and performance. Kohler's premium limited warranty covers parts, labor, and o Meets emission regulations for U.S. Environmental travel for the full warranty period. Protection Agency (EPA) with both natural gas and LPG. • Powerful Performance o UL2200/cUL listed. Exclusive Powerboost- technology provides excellent o Accepted by the Massachusetts Board of Registration of starting power. § Plumbers and Gas Fitters. o Meets 181 mph wind rating. • Aluminum Enclosure • Approved for stationary standby applications in locations o Attractive aluminum enclosure allows installation as close as 18 inches from your home or small business. t served by a reliable utility source (on -grid). o Enclosure panels can be removed without tools to allow • Exercise Modes easy access for maintenance and service. o Unloaded weekly exercise with complete system diagnostics (20 minutes). • Enclosure Options for single-phase units c Unloaded full -speed exercise (20 minutes). o Kohler® Exclusive Colors are available. Go to o Loaded full -speed exercise (20 minutes; Model RXT ATS KohlerGenerators.com to see the latest colors. required). o Camouflage Enclosures are available (optional). Go to a Model 20RCAL includes a model RXT automatic transfer KohlerGenerators.com/MossyOak to view the available switch. See last page for more details. patterns. Mossy Oak is a trademark used under license from Haas Outdoors, Inc., by Kohler Co. Generator Ratings Standby Ratings Line Circuit Natural Gas LPG Breaker Model Alt Voltage Ph Hz kW/kVA Amps kW/kVA Amps Amps Poles 20RCA 20RCAL 2F7 120/240 1 60 18/18 75 20/20 84 100 2 120/208 3 60 17/21 59 17/21 59 70 3 20RCA 2137 120/240 3 60 17/21 51 17/21 51 60 3 277/480 3 60 17/21 26 17/21 26 30 3 Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loadswith an average load factor of 80%for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO- 3046/1, BS5514, AS2789, and DIN 6271. GENERAL GUIDELINES FOR DEFLATING: ALTITUDE: Derate 49/ per 305 m (1 000ft.) elevation above 153 m (500 ft.). TEMPERATURE: Derate 2% per 5.5°C (10' F) temperature increase above 16°0(60'F). Availability is subjectto change without notice. The generator set manufacturer reservesthe right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co. generator dealer for availability. § Check the appliance manufacturer's specifications for actual power requirements. Consult a Kohler® Power Systems professional to calculate your exact residential power system requirements. f Meets NFPA guidelines for 18 inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure. GENERATOR SPECS. 34-272 (20RCA) 7/23f Alternator Specifications Specifications Alternator Specifications Alternator Features Alternator • Compliance with NEMA, IEEE, and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole, Rotating Field • Self -ventilated and dripproof construction. Leads, quantity 21`7 4 • Windings are vacuum -impregnated with epoxy varnish for dependability and long life. 2G7 12 Voltage regulator Digital • Superior voltage waveform and minimum harmonic Insulation: NEMA MG1-1.66 distortion from skewed alternator construction. Material Class H • Digital voltage regulator with �1.0% no-load to full -load Temperature rise 130°C Standby RMS regulation. Bearing: quantity, type 1, Sealed • Rotating -field alternator with static exciter for excellent Coupling P 9 Direct load response. P Amortisseur windings Full • Total harmonic distortion (THD) from no load to full load with Voltage regulation, no-load to full -load RIMS :t 1.0% a linear load is less than 5%. One-step load acceptance 100% of Rating Peak motor starting kVA: (35% dip for voltages below) 240 V, 1 ph 2F7 (4 lead) 41 (60 Hz) 240 or 480 V, 3 ph 2G7 (12 lead) 69 (60 Hz) Application Data Engine Exhaust Engine Specifications Exhaust System Manufacturer Kohler Exhaust temperature exiting the Engine: model, type CH1000 4-Cycle enclosure at rated kW, dry, °C (° F) 260 (500) Cylinder arrangement V-2 Lubrication Displacement, cm3 (cu. in.) 999 (61) Bore and stroke, mm (in.) 90 x 78.5 (3.54 x 3.1) Lubricating System Compression ratio 8.81 Type Full Pressure Main bearings: quantity, type 2, Heavy -Duty Sleeve Oil capacity (with filter), L (qt.) § 1.9 (2.0) Bearings Oil filter: quantity, type § 1, Cartridge Rated RPM 3600 Oil cooler Integral Max. engine power at rated rpm, kW (HP) § Kohler recommends the use of Kohler Genuine oil and filters. LPG 23.0(30.9) Fuel Requirements Natural gas 20.2 (27.1) Fuel System Cylinder head material Aluminum Valve material Steel/Stellite@ Fuel types Natural Gas or LPG Fuel supply inlet 1!2 NPT Piston type and material Aluminum Alloy Fuel supply pressure, kPa (in. H20): Crankshaft material Heat Treated, Ductile Iron Natural gas 0.9-2.7 (3.5-11) Governor: type Electronic LP 1.7-2.7 (7-11) Frequency regulation, no load to full load Isochronous Frequency regulation, steady state ±0.5% Fuel Composition Limits Nat. Gas LPG * Air cleaner type Dry Methane, % by volume (minimum) 90 min. - Ethane, % by volume (maximum) 4.0 max. Engine Electrical Propane, %by volume 1.0max. 85min. Engine Electrical System Propene, % by volume (maximum) 0.1 max. 5.0 max. Ignition system Electronic, C4 and higher, % by volume 0.3 max. 2.5 max. Capacitive Discharge Sulfur, ppm mass (maximum) 25 max. Starter motor rated voltage (DC) 12 Lower heatm value, MJ/m3 (Btu/ft�, (minimum) 33.2 (890) 84.2 (2260) Battery (purchased separately): Contact your local dealer for suitability and rating derates based on Ground Negative fuel compositions outside these limits. Volts (DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA) rating for -18°C (0°F) 500 Group size 51 G4-272 (20RCA) 7/2Bf rn C B A o � LQ- o RECEIVED 8/28/23 LLB v z LL1 O w N O r LL LLJ CV V C�_ Z ZL O C� O W LL1 Cl V-) = LLB LLB �z> Q Li Q W = v O Z O O O O Cr) DRAWN DATE: 08/24/2023 DRAWN BY: TL CHECKED BY: TL PROJECT NO. 201202 SHEET NAME D ETAI LS SHEET NUMBER A02 PRINT DATE: 07/31/2023