REVIEWED Heating Calculations+3.3.2022_11.55.37_AM+2715120REVIEWED RECEIVED 3/17/2022 Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and AC'C9'�o` F\lFI Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine coolinq`lnaB'. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information GETACHEW & SOLOMON RESIDENCE LEIF HELLEREN Heating System Type: O All Other Systems OO Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) Edmonds '7 J AT =Indoor (70 degrees) -Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) F 3,683 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.1 33,515 Glazing and Doors U-Factor X Area = UA Instructions aze 0.280 840 235.20 Skylights U-Factor X Area = UA Instructions 0.50 0� Insulation Attic U-Factor X Area = UA Instructions R 4g I 0.026 J 2,387 62.06 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instruction No Vaulted Ceilings in this project. --- Above Grade Walls (see Figure 1) U-Factor X Area UA In 61 1Intermediate 0.056 F-3,5997 201.54 Floors U-Factor X Area UA Instruc. in R-38 I 0.025 F 2,382 59.55 J Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions No Below Grade Walls in this project. � I 0.028 1 00 Slab Below Grade see Figure 1) F-Factor X Length UA Instructions60 No Slab Below Grade in this project. � I 0.303 J 00 Slab on Grade (see Figure 1) F-Factor X Length UA in I No Slab or Grade this project. J Location of Ducts Instructions I Duct Leakage Coefficient Conditioned Space J 1.00 Sum of UA 558.36 Figure 1. Above Grade 46 Envelope Heat Load 25,684 Btu / Hour Sum of UA x AT Air Leakage Heat Load 16,650 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 42,335 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 42,335 Btu / Hour Ducts in unconditioned soace: sum of buildina heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 52,918 Btu / Hour Buildino and duct heat loss x 1.40 for forced air furnace Buildino and duct heat loss x 1.25 for heat puma (07101113)