Loading...
GU-421 - Type 1 MH2" TO 6" CONC RISERS (4" MIN — 18" MAX) USING NON SHRINK GROUT PROVIDE SMOOTH FINISH INSIDE AND OUT 2 HANDHOLDS SEE COE STD DTL GU-423 POLYPROPYLENE SAFETY STEP/LADDER 12" OC PRECAST SECTIONS 4" MIN THICKNESS 11 TYP MIN SAND COLLAR DR KOR—N—SEAL MANHOLE <NOCKOUT STEPS FRAME AND COVER NOTES: 1. LOCATE MH LID OUTSIDE THE WHEEL PATH OF THE TRAVEL LANE. 2. BASE REINFORCING SHALL BE #4 REBAR AT 12" OC BOTH WAYS. 3. LARGER MH TO BE REVIEWED ON A CASE BY CASE BASIS USING APWA STANDARDS. 4. STEP AND LADDER MAY BE USED IN LIEU OF POLYPROPYLENE SAFETY STEPS. SEE COE STD DTL GU-423. CITY OF EDMONDS PUBLIC WORKS DEPARTMENT `St. 18y- MH FRAME AND COVER PER COE STD DTL GU-420 _ _ _ �10" MIN TO 24" MAX 24" 28" MAX d� 1 L < 6" MAX ° ECCENTRIC PRECAST CONE < d n n < d a SEE NOTE 4 °e 48" MIN , da d $ e a d 16" MAX CONSTRUCT CHANNEL SHELF 6" MIN REBAR MIN 2" CLEARANCE TYPE I MH APPROVED BY: R. ENGLISH REVISION DATE OCTOBER 2021 STANDARD DETAIL GU-421