Loading...
APPROVED BLD PLN BLD2023-0170+Mechanical_Plan+2.10.2023_7.58.05_AM+3362668m 3 0 �I N N N c�'.� 0 m w N 'o 0 m a` 0 0 0 w U N N 7 N r MECHANICAL GENERAL ABBREVIATIONS ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME AC AIR CONDITIONING UNIT FCU FAN COIL UNIT NOM NOMINAL AFF ABOVE FINISHED FLOOR FD FIRE DAMPER NTS NOT TO SCALE AHU AIR HANDLING UNIT FLA FULL LOAD AMPS OBD OPPOSED BLADE DAMPER AL ALUMINUM FOB FLAT ON BOTTOM OD OUTSIDE DIMENSION BAS BUILDING AUTOMATION SYSTEM FOT FLAT ON TOP POC POINT OF CONNECTION BDD BACK DRAFT DAMPER FSD FIRE SMOKE DAMPER PRV PRESSURE REDUCING VALVE BI BLACK IRON GALV GALVANIZED PVC POLYVINYL CHLORIDE BOD BOTTOM OF DUCT GC GENERAL CONTRACTOR REQ'D REQUIRED BOTT BOTTOM GENX GENERATOR EXHAUST RPBA REDUCED PRESSURE BACKFLOW ASSY BTU BRITISH THERMAL UNITS GLVNL GALVANNEAL RTU ROOFTOP UNIT BTUH BRITISH THERMAL UNITS PER HOUR GPM GALLONS PER MINUTE SA SUPPLY AIR CAT1 CATEGORY ONE VENT GREASE GREASE DUCT SD SMOKE DAMPER CAT4 CATEGORY FOUR VENT GWB GYPSUM WALL BOARD SL SOUND LINED CFM CUBIC FEET PER MINUTE HP HORSE POWER, HEAT PUMP SM SHEET METAL CPVC CPVC MATERIAL HVAC HEATING, VENTILATION AND AIR COND. SP STATIC PRESSURE DB DUCTBOARD HX HEAT EXCHANGER SS STAINLESS STEEL DDC DIRECT DIGITAL CONTROLS ID INSIDE DIMENSION SUSP SUSPENDED DEMO DEMOLISH LAT LEAVING AIR TEMPERATURE T THERMOSTAT DIFF DIFFUSER LBS POUNDS TOD TOP OF DUCT DMPR DAMPER LWT LEAVING WATER TEMPERATURE TV TURNING VANES DN DOWN MAT MIXED AIR TEMPERATURE TYP TYPICAL E EXISTING MBH ONE THOUSAND BTUH UNO UNLESS NOTED OTHERWISE EAT ENTERING AIR TEMPERATURE MCA MINIMUM CIRCUIT AMPACITY VAV VARIABLE AIR VOLUME EC EGGCRATE MD MOTORIZED DAMPER VD VOLUME DAMPER EER ENERGY EFFICIENCY RATIO MIN MINIMUM VFD VARIABLE FREQUENCY DRIVE EF EXHAUST FAN M-M MACDONALD-MILLER W DUCT INSULATION WRAP ELEV ELEVATION NC NORMALLY CLOSED W/ WITH ESP EXTERNAL STATIC PRESSURE NIC NOT IN CONTRACT WELD WELDED EWT ENTERING WATER TEMPERATURE NO NORMALLY OPEN rd VOLTAGE PHASE &DUCT DIAMETER HVAC SYSTEM ABBREVIATIONS ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME COMB-GALV COMBUSTION AIR EA AL EXHAUST ALUMINUM OA OUTSIDE AIR SA SUPPLY AIR LP EA SS EXHAUST SS 304 OA-KOOL OUTSIDE AIR KOOLDUCT SA-KOOL SUPPLY AIR LP KOOLDUCT EA AL WELD EXHAUST ALUMINUM WELDED RLF RELIEF AIR SA AL SUPPLY AIR LP ALUMINUM EA GALV WELD EXHAUST GALV WELDED RA RETURN AIR SA SS SUPPLY AIR LP SS 304 2B EA GLVNL WELD EXHAUST GALVANNEAL WELDED DB DUCTBOARD SA AL WELD SUPPLY AIR LP ALUMINUM WELDED EA SS WELD EXHAUST SS 304 WELDED FLU-CAT1 FLUE VENT -CATEGORY 1 SA GALV WELD SUPPLY AIR MP GALV WELDED EA BI GREASE EXHAUST GREASE BLACK IRON WELD FLU-CAT4 FLUE VENT -CATEGORY 4 SA GLVNL WELD SUPPLY AIR MP GALVANNEAL WELD EA GALV GREASE EXHAUST GREASE GALV WELDED FLU-CPVC FLUE VENT -CPVC MATERIAL SA SS WELD WELDED SUPPLY AIR LP SS 304 2B EA GALV GREASE EXHAUST GREASE SS 304 WELDED FLU -SS FLUE VENT -SHOP BUILT SS 304 EA EXHAUST AIR MUA MAKE-UP AIR FLU-GALV FLUE VENT -SHOP BUILT GALV ACOUSTICAL ANALYSIS EQUIP. DISTANCE SOUND MAX. RATED ACOUSTICAL # OF EQUIP. BARRIER SOUND TO CLOSEST DISTANCE LEVEL ZONING OF ZONING HOURS OF EQUIP. ALLOWABLE UNIT # SOUND ADD'N PER REFLECTIVE LOCATION SHIELDING PATH ADJACENT REDUCTION @ADJ. SENDING OF REC'G OPERATION SOUND LEVEL POWER ARI275-97 SURFACES FACTOR FACTOR FACTOR PROPERTY FACTOR PROP. PROP. PROP. (dBA)* (Dba) (FT.) (dBA) AHU-1 67 0 0 0 0 0 75 29.0 38 COMM COMM 12 HOURS 60 AHU-2 67 0 0 0 0 0 75 33.0 34 COMM COMM 12 HOURS 60 AHU-3 71 0 0 0 0 0 64 34.0 37 COMM COMM 12 HOURS 60 AHU-4 70 0 0 0 0 0 29 34.0 36 COMM COMM 12 HOURS 60 PER CITY OF EDMONDS NOISE ORDINANCE & ARI-275 PACKAGED HEAT PUMP SCHEDULE UNIT N0. AHU-1 (EXIST) AHU-2 (EXIST) AHU-3 (EXIST) AHU-4 (EXIST) AHU-1 AHU-2 AHU-3 AHU-4 MFG &MODEL N0. TRANE/YCC018F-L TRANE/YCC018F-L TRANE/YCC048F-M TRANE/YCC030E-L TRANE/4WCZ5024"1000 TRANE/4WCZ5024'1000 TRANE/4WCZ5048*1000 TRANE/4YCC4030'1000 NOM TONS 1.5 1.5 4.0 2.5 2.0 2.0 4.0 2.5 MBH 18.0 18.0 46.5 29.2 19.7 19.7 47.5 30.0 CFM 600 600 1600 1000 630 630 1600 1000 ESP 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 FAN HP 1 1/4 1 1/4 1 3/4 1- 1/3 1/2 1/2 3/4 1/2 MIN OA CFM 120 120 320 200 126 126 320 200 HSPFI COP - - - - 7.25/3.41 7.25/3.41 6.7/3.71 7.25/3.41 EER/ SEER 9.35/10.0 9.35/10.0 8.9/10.0 9.2/10.0 11.0/15.0 11.0/15.0 11.0/15.0 11.0/15.0 VOLT/PH 208/1 208/1 208/1 208/1 208/1 208/1 208/1 208/1 ELECTRICAL AUX HTR KW GAS 40,000 BTUH GAS 40,000 BTUH GAS 80,000 BTUH GAS 40,000 BTUH 3.7/5.0 3.7/5.0 6.0/8.0 3.7/5.0 WT LBS 451 451 557 451 507 507 642 516 � NOTES EXISTING EXISTING EXISTING EXISTING NEW, 1-12 NEW, 1-12 NEW, 1-12 NEW, 1-12 MCA 13.2 13.2 33 33 52 52 76 49 NOTES: 1. POWER WIRING AND DISCONNECT.SWITCH PROVIDED BY ELECTRICAL CONTRACTOR. 2. W/SINGLE POINT POWER CONNECTION. 3. W/ 1" 2" FILTER FRAME AND MERV-8 FILTER. 4. W/CRANKCASE HEATER. 5. W/ EVAPORATOR DEFROST CONTROL. 6. W/ LIFTING LUG KIT . 7. W/ R-410 REFRIGERANT . 8. ECONOMIZER WITH BAROMETRIC RELIEF. 9. CURB ADAPTOR. 10. MOUNT UNIT AND CURB ADAPTOR IN ACCORDANCE WITH THE STRUCTURAL DRAWINGS AND CALCULATIONS. 11. UNITS MEET THE MINIMUM EFFICIENCIES PER TABLE C403.3.2(2) OF THE WSEC. 12. WEIGHT INCLUDES UNIT, ECONOMIZER AND CURB ADAPTOR. PACKAGED UNIT SEQUENCE OF OPERATION ROOFTOP PACKAGE HEAT PUMP WITH ELECTRIC HEAT SERVES: SINGLE ZONE HEATING AND COOLING CONTROL TYPE: LOCAL OCCUPIED HOURS: 6:OOAM TO 6:00 PM MONDAY THROUGH FRIDAY. SUBJECT TO HOLIDAY AND EVENT SCHEDULING OCCUPIED HEATING SETPOINT: 70°F (ADJ.) UNOCCUPIED HEATING SETPOINT: 55°F (ADJ.) OCCUPIED COOLING SETPOINT: 75°F (ADJ.) UNOCCUPIED COOLING SETPOINT: 85°F (ADJ.) DESCRIPTION: ROOFTOP PACKAGED HEAT PUMP WITH ELECTRIC HEAT OCCUPIED: DURING THE OCCUPIED HOURS, THE SUPPLY FAN RUNS CONTINUOUSLY, THE OUTSIDE AIR DAMPER IS OPEN TO THE MINIMUM POSITION AND THE ECONOMIZER AND MECHANICAL COOLING OPERATE IN SEQUENCE TO MAINTAIN THE OCCUPIED COOLING SETPOINT. THE UNIT STAGES THE ELECTRIC HEAT AS NEEDED TO MAINTAIN THE OCCUPIED ROOM HEATING SETPOINT. WHEN THE UNIT IS IN THE HEATING POSTURE, THE OUTSIDE AIR DAMPER REMAINS IN THE MINIMUM POSITION UNOCCUPIED: DURING THE UNOCCUPIED MODE, THE SUPPLY FAN IS OFF, THE OUTSIDE AIR DAMPER IS CLOSED AND BOTH MECHANICAL COOLING AND HEATING ARE DISABLED NIGHT SETBACK: WHEN THE SPACE TEMPERATURE FALLS BELOW THE UNOCCUPIED TEMPERATURE SETPOINT, THE FAN AND HEAT ARE CYCCED AS NEEDED TO BRING THE SPACE UP TO THE NIGHT SETPOINT TEMPERATURE. THE OUTSIDE AIR DAMPER REMAINS CLOSED DURING THIS MODE. NIGHT SETUP: WHEN THE SPACE TEMPERATURE RISES ABOVE THE UNOCCUPIED TEMPERATURE SETPOINT, THE FAN IS CYCLED, AND THE ECONOMIZER AND MECHANICAL COOLING ARE MODULATED TO RETURN THE SPACE TO THE UNOCCUPIED SETPOINT. MORNING COOL DOWN: AT 2 HOURS (UP TO 4 HOURS AFTER A WEEKEND OR HOLIDAY) BEFORE THE OCCUPIED PERIOD, THE BMS BEGINS MONITORING THE OUTSIDE AIR TEMPERATURE AND THE SPACE TEMPERATURE AND DETERMINES WHEN THE UNITS SHOULD BE ENABLED IN THE MORNING COOL DOWN POSTURE. MORNING COOL DOWN USES ECONOMIZER AS THE FIRST STAGE OF COOLING BEFORE MECHANICAL COOLING IS ENABLED. IF THE OUTSIDE AIR IS NOT SUITABLE FOR ECONOMIZER USE, THE OSA DAMPER IS CLOSED. MORNING WARM UP: AT 2 HOURS (UP TO 4 HOURS AFTER A WEEKEND OR HOLIDAY) BEFORE THE OCCUPIED PERIOD, THE BMS BEGINS MONITORING THE OUTSIDE AIR TEMPERATURE AND THE SPACE TEMPERATURE AND DETERMINES WHEN THE UNITS SHOULD BE ENABLED IN THE MORNING WARM UP POSTURE. THE ELECTRIC HEAT IS STAGED/MODULATED AS DETERMINED BY THE ONBOARD UNIT CONTROLS TO MEET THE SPACE HEATING DEMAND. THE OUTSIDE AIR IS CLOSED DURING THIS MODE. ENERGY COASTING: AT UP TO 2 HOURS BEFORE THE BEGINNING OF THE UNOCCUPIED PERIOD, THE COOLING SETPOINT IS ALLOWED TO DRIFT LINEARLY UP 2°F (ADJ) SAFETIES: - ECONOMIZER FAULT DETECTION AND DIAGNOSTICS PER WSEC SECTION 403.2.4.7 - MAINTAIN A 5° DEADBAND BETWEEN THE HEATING AND COOLING SETPOINTS PER WSEC SECTION 403.2.4.1.2 DISPLAY, TRENDING AND ALARM: - MODE '- ECONOMIZER STATUS -DISCHARGE AIR TEMPERATURE -ECONOMIZER AVAILABLE - ROOM TEMPERATURE -COMPRESSOR STATUS (EACH STAGE) - RETURN AIR TEMPERATURE -HEATING STAGE STATUS - OUTSIDE AIR TEMPERATURE -SUPPLEMENTAL HEAT LOCKOUT STATUS - OSA DAMPER POSITION (COMMANDED) HVAC GENERAL NOTES - 2018 WA STATE 00 E ^L^,, W V � o 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS Q TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. � � � �' E 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2018 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL � � FIRE CODE 2018 WSEC, AND LOCAL CODES AND ORDINANCES. �_ � E 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2018 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH � � - � � ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. � o 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. � (/ � p �_ � 3 � 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2018 WASHINGTON STATE ENERGY CODE, COMMERCIAL PROVISIONS O � � c�'o Q _ -a r� 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED m oN CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. U �! Q � 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2018 IBC. � LL � � �a 8. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2018 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. BAS TO MONITOR FIRE ALARM CONTROL PANEL AND SHUT DOWN ALL FAN TERMINAL UNITS DURING ANY BUILDING FIRE ALARM EVENT, IN ACCORDANCE WITH 2O18 IMC 606.2.2. 9. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18". 10. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 11. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 12. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 13. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH 2O18 WASHINGTON STATE ENERGY CODE (WSEC), COMMERCIAL PROVISIONS AND SECTION C408. PLEASE SEE SCHEDULED COMMISSINING NOTES FOR FURTHER DETAIL. 14. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER LEGAL DESCRIPTION PARCEL NUMBER: 00580700002500 LEGAL DESCRIPTION: SOLNERS 5 ACRE TRACTS BLK 000 D-00 - N 1/2 OF TRS 27 & 28 & S 1/2 OF TRS 25 & 26 TGW TH PTN OF VAC 10TH ST SE (FORMERLY 216TH ST SW ADJ THRTO) &TGW TH PTN OF TR 29 SD PLAT LY WLY OF FDL - COM AT NWCOR SD TR 29 TH ELY ALG N BDY 42.12FT TO BEG OF LN HEREIN DESC TH SLY TAP 35.44FT FR SW CR OF SD TR 29 AS MEAS ALG S BDY SD TR &TERM OF LN HEREIN DESC (PER CITY EDM BLA REC AF NO 199909155005) SCOPE OF WORK REPLACE (4) EXISTING TRANE PACKAGE HEAT PUMP GAS/ELCTRIC UNITS WITH NEW ELECTRIC UNITS. REPLACE (4) NEW CURB ADAPTERS,1 FOR EACH PACKAGE HEAT PUMP UNIT. REMOVE NATURAL GAS PIPING TO EXISTING ROOFTOP UNITS AND CAP. REMOVE NATURAL GAS PIPING AT GAS METER, CAP AND MAKE SAFE. CONTACT LIST TITLE NAME COMPANY PHONE NUMBER EMAIL PROJECT EXECUTIVE JOSH KLINE MACDONALD MILLER 206-403-8533 JOSH.KLINEp�MACMILLER.COM PRINCIPAL TODD BOVEY MACDONALD MILLER 206-768-3984 TODD.BOVEY@MACMILLER.COM SENIOR DESIGN ENGINEER CHRIS LEE MACDONALD MILLER 206-768-4266 CHRIS.LEE@MACMILLER.COM DESIGNER MARC RYPDAHL MACDONALD MILLER 503-262-5418 MARC.RYPDAHL@MACMILLER.COM DRAWING SHEET INDEX -HVAC NUMBER TITLE TM0.01 SCHEDULES -HVAC TM0.01S SITE PLAN DM2.03 ROOF DEMO PLAN -HVAC TM2.03 ROOF PLAN -HVAC TM3.01 ELEVATIONS -HVAC TM3.02 ELEVATIONS -HVAC ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE = The following documentation shall be available on • ' site for the building inspector: � ❑ COE APPROVED ARCHITECTURAL PLAN SET ' ■ ; ❑ COE APPROVED STRUCTURAL PLAN SET ®COE REVIEWED CALCULATION PACKET � � ❑ENERGY CREDIT WORKSHEET ■ , ❑SITE PLAN ■ ❑CIVIL PLAN � ❑ � ■ , ■❑ � ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ; City Of Edmonds Building Department Work MECHANICAL -ROOFTOP UNITS Address 21605 76TH AVE W Owner SWEDISH Approved Date 02/23/2023 Building Official Erie C%arf�r Permit Number BLD2023-0170 APPROVED BY PLANNING �� ���� Feb 23 2023 215TH ST SW � � Q � o o z 216TH ST SW r� (V � 216TH ST SW SITE �� � I� T� a 218TH ST SW �� C7� 220TH ST SW RECEIVED Feb 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 3 W H Q 0 z 0 w W H Q Z O W ^J I..L �'W/ I..L I..L O �W LL � Oz OW �U 0 J � QQ �U � � � pW W C� w � � � � N W � � � °' �Q� J � O LL Z �0�� Q W\ � �W�� 0 ��� _% U � � W��^^�� VJ N W �/� VJ � (� ENGINEER: LAST REVISED: M RYPDAHL 02-10-23 CHECKED BY: DATE PLOTTED: T BOVEY 02-10-23 CAD: ISSUE DATE: M HAGBERG 02-10-23 DRAWING NUMBER: C-2684-77221422-00 SHEET NUMBER: TM0.01 N VICINITY MAP NO SCALE Tuesday, February 7, 2023 3:46:00 PM II J:\7722\1422 - SMGED RAD Louver And Flashing Fab\00\2 -Engineering\DWG\Shts\77221422TM0_01.dwg II �� T j Oj O TO � 1 O V V n� rn Dz p r � � rn p ❑ O 0 z p ❑ v' 4' 3" n _ � c 0 �� �4"' �' w � � ,- � � � z G� � � � � �N � �� rn � �, �� �_ cn �� z � " D � 0 � m � Z N z = W L� m z m � O� c� D O o � ^' A � (� Z W T � V � m oo m p �, A m � D N ;U 2 N � r � O N o O O O � O D O D N i � N i � N � m i � � m � � � � A � � � N m N m N o W W � W EDMONDS ED RAD ROOFTOP REPL - SWEDISH MEDICAL CENTER = 21605 76TH AVE W _ EDMONDS, WA 98026 SITE PLAN - ISSUED FOR PERMIT REVISIONS: rn<� �l ^ ��{ � D � � � Azo o rn mcno N - �Ao O �� w rn v DATE REVISIONS: DATE w MacDonald -Miller �nr 1LITY SOLUTIONS 17930 Intl. Blvd. Suite 120, SeaTac, WA 98188 Phone:206-763-9400 www.macmiller.com m 3 ri 0 N N V N 0 m .� w N O li C L LL Q J 0 0 W U N N 7 N N DEMO GAS PIPING BACK TO METER, CAP GAS LINE CONNECTION AT THE GAS METER AND MAKE SAFE REMOVE EXISTING ROOFTOP UNIT ,DISCONNECT POWER, GAS CONNECTION AND DUCTWORK (TYP 4) a 0 M 0 a M N O N 2 3 4 5 DEMO GAS PIPING BACK TO METER, CAP GAS LINE CONNECTION AT THE GAS METER AND MAKE SAFE 6 N L � C 00 O Z a` O �' E V U J o � O� o o _ � � � O � � C� p - �'� m � U _ CV �� C7 r G\ f ' 1..1 � � � � I I I I I I I I w Q 0 z O w I I I I I I I I � I I I I I I I I w Q 0 RECEIVED Feb 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z O w I I I I I I I I � ^� I..L mow/ L.L I..L O� �w Oz Ow �U pJ Z � Qa Q - �U J � p � � pw w w� O � � � � � N O p =�°° (n w Q w L.L z-Q� p� O � pro �� w �w�o O� � p ��� o � W�/'��o S � �+/NW � — ENGINEER: LAST REVISED: M RYPDAHL 02-10-23 CHECKED BY: DATE PLOTTED: T BOVEY 02-10-23 CAD: ISSUE DATE: M HAGBERG 02-10-23 DRAWING NUMBER: C-2684-77221422-00 SHEET NUMBER: DM2.03 a0 (0 2 d N LL T 9 N N C m 3 ri 0 N N V N 0 m .� w N O li C L LL Q J 0 0 W U N N 7 N N INSTALL NEW ROOFTOP UNIT AND CURB ADAPTER, CONNECT EXISTING DUCTWORK. DISCONNECT AND POWER WIRING BY ELECTRICAL (TYP 4) AHU-2 �, a z z a LL T 9 N N C 2 3 4 5 6 L � C 00 O Z a` 0 �' E V U J o � O� o o _ � � � O � � C� Q � � � m � U _ CV �� C7 r G\ f ' 1..1 � � � � 2-10-23 I I I I I I I I w Q 0 z 0 w I I I I I I I I � I I I I I I I I w Q 0 RECEIVED Feb 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z O w I I I I I I I I � ^� I..L �W/ L.L I..L O �% O ` O �U OJ Qa �U 0� ww � � Z Q N =� ° J Z�Q� �� 00�� �� � wiz O � 0 ��� O W�/'��o �+/NW I..L ENGINEER: LAST REVISED: M RYPDAHL 02-10-23 CHECKED BY: DATE PLOTTED: T BOVEY 02-10-23 CAD: ISSUE DATE: M HAGBERG 02-10-23 DRAWING NUMBER: C-2684-77221422-00 SHEET NUMBER: TM2.03 w O LL 0 w m 3 0 M N N N N n C7 0 o� c m c w N O t0 C L Q 0 J 0 Q 0 U N N 7 N N ADJACENT BUILDING (HOSPITAL) 1 0 ih AHU-1 TOP OF PARAPET TOP OF ROOF 1 RTU BEHIND AHU-4 AHU-3 AHU-2 M AHU-4 WEST ELEVATION SOUTH ELEVATION EL.: 402.5' EL.: 386.5' ,� EL.:370.5' I` � C r C U �� L L °' � !_ C V U L � (6 r � � � C V, � O �_ � 3 � O � (� M Q � � m Q U�=N (� Q LL � � �a w Q 0 z O w w Q 0 RECEIVED Feb 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z O w I I I I I I I I � J W O� � W L.L � Oz OW �U OJ Qa � �U � 0 QW W W 5 � � G � Z " O O � _�� - z �Q� � � LL O 0 = � a \ 0 �W�� >� � W � o ��� �o S � WC�Nw W - ENGINEER: LAST REVISED: M RYPDAHL 02-10-23 CHECKED BY: DATE PLOTTED: T BOVEY 02-10-23 CAD: ISSUE DATE: M HAGBERG 02-10-23 DRAWING NUMBER: C-2684-77221422-00 SHEET NUMBER: TM3.01 3 0 ml N N N N r w` N O (6 Q 0 J Q CY 0 W U N N N N r I IAIITC LJIflflCAl QCLJIAIfI EAST ELEVATION EL.: 402.5' EL.: 386.5' � EL.:370.5' �� 8 7 6 5 4 3 2 1 1 RTU BEHIND -- -- -- � 0 M M NORTH ELEVATION N O _ T f6 a N J EL.: 402.5' EL.: 386.5' EL.: 370.5' W � � O � Q i - 5 O C� � I_ G � V U � � N J o � Oro O _ � ` O / � ,��^ VJ M Q J m o UC =" � � �� �� � D_ I I I I I I I I w Q 0 c� z 0 w I I I I I I I I � I I I I I I I I w Q 0 RECEIVED Feb 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z O w I I I I I I I I � J W O� � W L.L � Oz OW �U 0 J �U 0 W 5W C7n G cfl Z N O Z�Q� �� �0= a\ �� � �z W � 0 ��� J W�/'��o .+/NW W ENGINEER: LAST REVISED: M RYPDAHL 02-10-23 CHECKED BY: DATE PLOTTED: T BOVEY 02-10-23 CAD: ISSUE DATE: M HAGBERG 02-10-23 DRAWINGNUMBER: C-2684-77221422-00 SHEET NUMBER: TM3.02 C� G ^W L.� O 0 W