Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2022-0789+Interior_Lighting_Summary+6.17.2022_12.01.13_PM+2939225
6/15/22, 11:08 AM hftps://waenergycodes.com/print_project_summary_form.php?k=aWQ9MTEzOTcmZnZpPTE4JnJlc2VOPTE=&debug=1 LIGHTING COMPLIANCE SUMMA 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl Administered by: ©2022 NEEA, All rights reserved Project Title 22-101 Edmonds Medical Plaza Suite 202 TI - 2018 WSEC For Building Department Use: I Date: Jun 15, 2022 216116 76TH AVENUE WEST Project Address 202 RECEIVED Project &Applicant EDMONDS, WA 98026 •••• •• Information REVIEwE� Jun 21 2022 BLD2022-0789 BY Applicant Name Austin Edge Cm OF EDMONDS CITY OF EDMONDS DEVELOPMENT SERVICES --N..-T-T Applicant Phone 425-458-9700 Applicant Email aedge@designwesteng.com DEPARTMENT:................................. �.....,.,..-. For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Medical Building Cond. Floor Area 1,165 General Project Types Tenant Spaces — First Build Out New Building or Addition Lighting Scope g g P Interior Lighting Alteration Lighting Scope Project Cond. Floor Area 1,165 Floors Above Grade 2 Compliance Method Compliance Method 1 -General Lighting Project Description Lighting Compliance Scope Pro jP ect a Interior / Exterior (Interior includes both interior & parking Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification and Method Tenant Spaces — First Build Out Interior Lighting Space by space No Calculation Adjustments selected COMPLIES Additional Efficiency Options Included 22-101 Edmonds Medical Plaza Suite 202 TI - 2018 WSEC Jun 15, 2022 Lighting Power Calculation TENANT SPACES — FIRST BUILD OUT - INTERIOR LIGHTING Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Ceiling Height (Ft) Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Lobby General 120 0.84 101 Lobby General 48 0.84 40 Office Enclosed less than 250 sf 72 0.74 53 Office Enclosed less than 250 sf 61 0.74 45 Restroom General 50 0.63 32 Healthcare facility Corridor 185 0.71 131 Healthcare facility Exam/treatment room 103 1.40 144 Healthcare facility Exam/treatment room 92 1.40 129 Healthcare facility Exam/treatment room 1 92 1 1.40 129 Healthcare facility Exam/treatment room 1 80 1 1.40 112 Healthcare facility Lounge/breakroom 1 116 1 0.42 49 Proposed Total LPD 684 Totals 965 684 COMPLIES Proposed Lighting Power Density Watts or Total Watts Fixture Type Fixture ID Quantity of Wattage Limit Total Linear Watts per Linear Proposed Fixtures (#F) per Fixture Feet (LF) Foot (WpLF) (#F x WpF) or (WpF) (LF x WpLF) Individual Fixtures Troffer F1/E 12 27 324 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9MTEzOTcmZnZpPTE4JnJlc2VOPTE=&debug=1 1 /2 6/15/22, 11:08 AM hftps://waenergycodes.com/print project_summary_form.php?k=aWQ9MTEzOTcmZnZpPTE4JnJlc2VOPTE=&debug=1 Troffer F2 7 27 189 Recessed downlight F3 7 21 147 Wall -mounted F4 1 24 24 Proposed Total LPD 684 Project Title 22-101 Edmonds Medical Plaza Suite 202 TI - 2018 WSEC Date Jun 15, 2022 Proposed Fixtures Details TENANT SPACES — FIRST BUILD OUT - INTERIOR LIGHTING 1 K Fixture Type/Application Fixture ID Location in Documents Lamp Type7 New or Existing -to -Remain Individual Fixtures Troffer F1/E E-1.1 LED New Fixture Description: 1X4 LED Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Troffer F2 1 E-1.1 LED New Fixture Description: 2X2 LED Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Recessed downlight F3 I E-1.1 LED New Fixture Description: LED DOWNLIGHT Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Wall -mounted F4 I E-1.1 LED New Fixture Description: LED VANITY LIGHT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: https://waenergycodes.com/print project_summary_form.php?k=aWQ9MTEzOTcmZnZpPTE4JnJIc2V0PTE=&debug=1 2/2