Loading...
REVIEWED BLD-RESUB 1-Structural_Calculations+4.29.2021_11.34.02_AM+2170801RESUB Apr 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TN Design Associates, AIA, Inc. Structural Calculations 9813 215th Street SW Seattle, Washington Prepared for Mace Burke & Janine Flowers Prepared by: Timothy Newberry, AIA 2905 158th Place SW Lynnwood, Washington ,2777 REGISTERED ARCHITECT TIM TI S RWR RV I STA F WASHIN T March 1, 2021 ............................................. REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT Page 1 1 1 Project Overview 1.1 Scope: A kitchen remodel and proposed small addition to the kitchen constructed over the top of an existing basement is being proposed in a residential building located at 9813 2151h Street SW, Edmonds, WA. The addition consists of approximately 98 sq. ft. of new interior living space. 1.2 Applicable Codes: The property is located outside the Edmonds City limits and within the Snohomish County limits. Thus the 2015 International Residential Code (IRC), 2015 International Building code (IBC), and 2015 American Wood Council Manual (AWC) apply. 2 Building Information ❖ Single-family Multi -Level Residential Building ❖ Conventional light wood framing ❖ The foundation of the basement consist of slab on grade with spread footing, CMU and Wood framed perimeter walls. (step out basement) ❖ The existing roof consists of composite shingles ❖ The existing exterior walls are covered with wood plank siding ❖ The additional living area will be framed above the existing basement. 3 Building Information 3.1 Dead Loads: Dead Loads were calculated using the existing or proposed size and materials (best guess for existing). The floor dead load as 12 psf. The weight for the exterior walls was taken as 10 psf. Page 1 2 3.2 Live Loads: Live Loads will be taken from the 2018 Washington State IRC amendment, table 1607. See table below: 2015 IBC Table 1607.1 With WA State Amendments OCCUPANCY OR USE MINIMUM UNIFORM CONCENTRATED DISTRIBUTED LIVE LOAD (psf) LOAD (Ibs) 5. Balcony & Decks 1.5 times load of area served - 14. Garages (Passenger Vehicles Only) 40 3000 25. Residential Uninhabitable Attic Without Storage 10 25. Residential Uninhabitable Attic With Storage 20 25. Residential Habitable Attic & Sleeping Areas 30 25. Residential All Other Areas 40 - 26. Roofs - Ordinary Flat, Pitched, & Curved Roofs (Non -Occupiable) 20 300 3.3 Seismic Loads: The seismic loads will be obtained using the ASCE 7-10 with a Seismic Design Category D2. 3.4 Wind Loads: The seismic loads will be obtained using the ASCE 7-10 with exposure B and the ultimate wind speed of 110 mph. 3.5 Snow Loads: A roof uniform load of 25 psf was used, as defined by the City of Edmonds building codes. 3.6 Earth Loads: Earth loads/pressures shall be obtained from the ASCE 7-10 code. The frost depth shall be taken as: One story 12 " Two story 18 " Three story 24 " Page 1 3 4 Beam Analysis: All bending members sized within this structure shall conform to the minimum deflection criteria as described in table 1604.3 of the 2018 IRC. An excerpt of this table is shown below: 2015 IBC Table 1604.3 Deflection Limits' L SOrWf D+Ld Roof Members Supporting Plaster Or Stucco Ceiling L/360 L/360 L/360 Supporting Nonplaster Ceiling L1240 L/240 L/180 Not Supporting Ceiling L/180 L/180 L/120 Floor Members L/360 - L/240 Exterior Walls With Plaster Or Stucco Finishes - L/360 - With Other Brittle Finishes - L/240 - With Flexible Finishes - L/120 - a: ine aerieciion nmiilortne u*c ioaw comoinat[on omyappnes io ine aeneQton owe to the creep component of long-term dead load deflection plus the short-term live load deflection. f: The wind load is permitted to be taken as 0.42 times the "component and cladding' loads for the purpose ofdeterminingdeflection limits herein. Where members support glass in accordance with section 2403 usingthe deflection limit therein, the wind load shall be no less than 0.6 times the "component and cladding" loads forthe purpose of determining deflection. is For cantli ever members, I - shall betaken as twice the length of the cantilever All bending members sized in this structural addition have undergone an evaluation that determines structural adequacy for all of the following: ❖ Shear ❖ Bending Moment •'• Plate Bearing ❖ Lateral Torsional Bracing Calculations indicating the structural performance of each member are summarized in sections 4.1 Page 14 4.1 Beam Analysis: fFORTE"CM MEMBER REPORT Level, Roof: Drop Beam i piece(s) 3 1/2" x 9 1/2" 24F-V4 OF Glulam Gverall Ler�g-h: 1G1jA 0 0 15' 6" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual cm Location Allowed ReSUIt LDF Load: combination (Pattern) Member Reaction (Ibs) 550 @ 2" 7656 (3.50") Passed (9%) — 1.0 D + 1.0 5 (All Spans) Shear files) 571 @ 1' 1" 6755 Passed (81%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 2545 @ 8' 1/2" 12109 Passed (21 h) 1.15 1.0 D + 1.0 S (All Spans) Live Load DeB. (in) 0.154 Cd 8' 1/2" 0.788 Passed (L/999+) -- 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.252 Cd 8' 1/2" 1.050 Passed (L/749) -- 1.0 D + 1.0 S (All Spans) • Dainestlon cril LL (U240) and TL (L1180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using langt)I L = 15' 9". • The effects of positive or negative camber have not been acwu nted fer when ea leulating deflection. • The specified glulam Is assumed to have its strong laminations at the bottom of the beam. install with proper side up as Indicated by the manufacturer. • Applicable calculations are based on NDS. Supports 113earin9 Lea9th Loads to Supports (Ill Accessories Total Available Required Dead Roof Live Snow I Total 1 - Stud wall - DF 3 SO" 3.50" 1.50" 256 1 322 902 1 982 Blocking 2 - Stud wall - DF 3.50" 3.50" 1.50" 258 322 402 982 Blocking Blocking Panels are assumed W carry no loads applied dirsdy, ahove them and the full load is applied to the member being designed, Lateral Bracing Bracing Intervals comments Tap Ed". (Lu)1 16' 1" o/c Bottom Edge (Lu) 16' 1" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.9o) Roof Live (non -snow: 1.25) Snow U is) Comments 0 - Self Weight (PILE) 0 W 16' 1" N/A 8.1 — -- 1 - Uniform (PSF) 0 to 16' r (Front) 2' 12.0 20,0 25.0 Default Load PASSED System : Reef Member Type : Dmp Beam Building Use : Residential Building Code : IBC 2015 Design Methodology: ASD Member Pitch : 0112 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software, Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Boats, Blocking Panels and Squash Blocks) are not designed by this software, Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by 7CC-ES under evaluation reports ESR-1153 and ESR-1387 and/ar tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeu ser.com(woodpmducts/document-I I b rary. The product application, input design loads, dimensions and support information have been provided by Formi Software Operator Fortei Software Operator lob Notes Tim Newheny TN Design Assoclates,AEA.Inc (808) 389-1452 cardontimCgmail-in 3/14/2021 3:50:07 PM UTC FcrteWEB 0.1, Engine: V8.1.6.2, Data: V8.0.1.0 xP4e,h,e ser File Name: ]an flowers Page 1 / 1 Page 15 5 Column Analysis: All column members sized within the structure shall conform to the minimum deflection criteria as described in Table 1604.3 of the 2018 IRC, found in section 4. All column members sized in this structural addition have undergone an evaluation that determines structural adequacy for all of the following: ❖ Slenderness •'• Lateral Bending •'• Plate Bearing •'• Lateral Deflection ❖ Bending/compression due to eccentric loading Page 1 6 1 F O R T E CM MEMBER REPORT PASSED Level, Free Standing Post 1 piece(s) 4 x 4 Douglas Fir -Larch No. 1 Post Height: 8' Design Results Actual Allowed Result LDF Load: Combination Slenderness 27 50 Passed (55%) - Compression (Ibs) 740 7479 Passed (10%) 1.00 1.0 D + 1.0 L Base Bearing (Ibs) 740 7656 Passed (10%) -- 1.0 D + 1.0 L Bending/Compression N/A 1 Passed (N/A) N/A • Input axial load eccentricity for the design is zero • Applicable calculations are based on NDS. Supports Type Material Member Type : Free Standing Post Base Plate Douglas Fir -Larch Building Code IBC 20 15 Design Methodology : ASD Max unbraced Length Comments Full Member Length No bracing assumed. Drawing is Conceptual Vertical Load Dead (0.90) Floor Live (1.00) Comments 1 - Point (lb) 660 80 Default Load Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 ancli tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www. were rh ae user. com/wood products/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Tim Newberry TN Design As.ciates,A]A.Inc (808)389-1452 carbontirr itcam 3/14/2021 3:56:17 PM UTC AForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0 wgrhneuser File Name: Jan flowers Page 1 / 1 6 Connections: All interior gravity load connection conditions were sized using Simpson Strong -Tie connectors. All uplift and exterior connectors were designed following provisions published in the Simpson Strong -Tie Design Manual, following design provisions published in the 2018 IRC and the 2018 American Wood Council National Design Specifications. (See Structural detail sheets for specific connection callouts) 6.1 Rafters to top plate Each rafter shall be attached to the double top plate using a minimum of a single H1 hurricane tie. (See Structural detail sheets for connection specific callouts) 6.2 Beam or Girder to column end cap Each column as specified on the plan shall be attached to the beam above using a column cap as specified, (See Structural detail sheets for connection specific callouts) Page 1 8