APPROVED BLD2023-0298+Plumbing_Plan+3.8.2023_10.51.14_AM+3408706
PLUMBING LEGEND SYMBOL ABBR. DESCRIPTION GW GW GREASE WASTE BELOW FLOOR S OR W SOIL OR WASTE BELOW FLOOR ---- - CWV COMBINATION WASTE & VENT BELOW - - - - - - - - - - - - - - - V VENT - - CW DOMESTIC COLD WATER ------------- HW DOMESTIC HOT WATER HWR HWR DOMESTIC HOT WATER RETURN GAS G LOW PRESSURE GAS CD CD PRIMARY CONDENSATE DRAIN XSS XSS EXISTING WASTE/SANITARY SEWER XGW XGW EXISTING GREASE WASTE XCW XCW EXISTING COLD WATER xc XG EXISTING GAS xHW XHW EXISTING HOT WATER FW FILTERED WATER FWFW T&P TEMPERATURE & PRESSURE �I WCO WALL CLEANOUT FCO FLOOR CLEANOUT SOV COLD WATER SHUT-OFF VALVE GSOV GAS SHUT-OFF VALVE C.V. CHECK VALVE PRV PRESSURE REDUCING VALVE BLV BALANCING VALVE GSOV AUTOMATIC GAS SHUT-OFF VALVE SOC SHUT-OFF COCK (GAS) TMV TEMPERATURE MIXING VALVE O VTR VENT TO ROOF POC POINT OF CONNECTION ® CP RECIRCULATION PUMP CW COLD WATER STUB-IN/HOSE BIBB HW HOT WATER STUB -IN (N) NEW (E) EXISTING (R) RELOCATED, EXISTING ABV ABOVE BEL BELOW CFH CUBIC FEET PER HOUR DN DOWN FF FINISHED FLOOR ELEVATION FLR FLOOR IE INVERT ELEVATION NTS NOT TO SCALE W/ WITH DCO DOUBLE CLEANOUT PIPE MATERIAL SCHEDULE C9' CO Ile O� Jv �O � o QQ� Gj SERVICE: OOQ OOQ OOQ �V� V�O � C9�V REMARKS: DOMESTIC INSIDE OUTSIDE o WATER SANITARY INSIDE OUTSIDE o WASTE SANITARY CONCEALED C EXPOSED o VENT INSIDE o USE COPPER INDIRECT TYPE "M" FOR OUTSIDE C WASTE CONDENSATE NATURAL INSIDE ° OUTSIDE o GAS NOTE: 1. ABS AND PVC INSTALLATIONS ARE LIMITED TO NOT MORE THAN TWO STORIES OF AREAS OF RESIDENTIAL ACCOMMODATION. 2. ABS/PVC VENT TERMINATIONS UP THROUGH THE ROOF EXPOSED TO SUNLIGHT ARE REQUIRED TO BE PROTECTED BY WATER BASED SYNTHETIC LATEX PAINTS. SHEET INDEX P000 PLUMBING NOTES & SCHEDULES P001 PLUMBING DETAILS P002 PLUMBING SPECIFICATION SHEETS P100 WASTE & VENT PLAN P200 WATER & GAS PLAN SCOPE OF WORK • EXISTING COMMERCIAL TENANT IMPROVEMENT. • PROVIDE NEW PLUMBING FIXTURES/CONNECTIONS TO THE RENOVATED AREAS. • NEW WATER HEATER(S) TO BE INSTALLED. GENERAL NOTES 1. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFY THE EXACT 15. ALL EXTERIOR GAS COCKS, WATER SHUTOFF VALVES AND/OR SEWER CLEAN OUTS LOCATIONS, ELEVATIONS AND CHARACTERISTICS OF ALL UTILITIES AND PIPING, AND BELOW GROUND SHALL BE INSTALLED IN YARD BOXES WITH THE COVERS SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. CONSPICUOUSLY MARKED "GAS", "WATER", AND "SEWER" RESPECTIVELY. 2. THE PLUMBING SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL CONFORM TO 16. EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE THE 2021 UPC AND AUTHORITIES HAVING JURISDICTION. IN CASE OF CONFLICTS OBTAINED FROM THE ARCHITECTURAL DRAWINGS. WITH CODES, DRAWINGS, OR SPECIFICATIONS, THE MOST STRINGENT SHALL PREVAIL. 17. SEE ARCHITECTURAL DRAWINGS FOR HANDICAP FIXTURE LOCATIONS AND MOUNTING HEIGHTS. INSULATE ALL EXPOSED HOT WATER AND DRAIN PIPING BELOW 3. THE DRAWINGS WERE PREPARED WITH THE BEST STRUCTURAL AND HANDICAP LAVATORIES AND SINKS WITH INSULATING TAPE AND OFFSET P-TRAP AGAINST ARCHITECTURAL INFORMATION AVAILABLE. IT IS UNDERSTOOD THAT EQUIPMENT WALL. ALL FLUSH VALVES FOR HANDICAP SHALL BE LOCATED ON HANDICAP LOCATIONS AND ROUTING OF PIPING MAY VARY FROM THAT SHOWN ON THE PLANS WHEELCHAIR ACCESS SIDE OF STALL. AS CONSTRUCTION PROCEEDS. IT IS THE CONTRACTORS RESPONSIBILITY TO: 18. ALL WASTE, SOIL AND VENT PIPING SHALL SLOPE AT 2% UNLESS OTHERWISE a. NOTIFY THE MECHANICAL ENGINEER OF CONSTRUCTION RESTRAINTS WHICH INDICATED. MAKE VARIATIONS FROM THE PLANS NECESSARY. 19. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT b. COMPLETE ALL WORK INCLUDING THE VARIATIONS WITHOUT CHARGING EXTRAS SHOWN IN WALLS OR ABOVE NON -ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND TO THE BID CONTRACT. COMPLETION OF WORK MEANS THE JOB IS WORKING AN ACCESS PANEL. AND MEETS ALL CITY, COUNTY AND UNIFORM MECHANICAL, PLUMBING AND BUILDING CODE REQUIREMENTS. 20. PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BASE BID. HE SHALL FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS AND FUTURE WORK TO BE DONE. 4. THESE DRAWINGS DO NOT INCLUDE ALL NECESSARY SAFETY REQUIREMENTS. HE SHALL INCLUDE ALL HIS SITE INFORMATION AND CONDITIONS WITHIN HIS BASE BID. CONTRACTOR TO COMPLY TO THE SAFETY REQUIREMENTS SET FORTH BY THE HE SHALL BE RESPONSIBLE FOR COMPLETE AND FULLY FUNCTIONING PLUMBING LOCAL AUTHORITIES HAVING JURISDICTION. SYSTEMS. 5. THESE DRAWINGS ARE FOR BIDDING PURPOSES ONLY. THEY ARE ESSENTIALLY 21. PLUMBING CONTRACTOR SHALL COORDINATE COMPLETE PLUMBING INSTALLATION DIAGRAMMATIC TO THE EXTENT THAT MANY OFFSETS, BONDS, UNIONS, SPECIFIC AND REQUIREMENTS PRIOR TO BASE BID WITH ALL LOCAL DISTRICTS AND GOVERNING FITTINGS AND EXACT LOCATIONS ARE NOT INDICATED. AUTHORITIES. INCLUDE ALL FINDINGS WITHIN THE BASE BID. 6. THE PLUMBING CONTRACTOR SHALL PROVIDE THE WATER, SEWER AND STORM 22. PROVIDE RECIRCULATION PUMP FOR HOT WATER WHEN THE HOT WATER PIPE IS DRAIN SYSTEMS AND CONNECT TO EACH DESIGNATED POINT OF CONNECTIONS 5'-0" OVER 50'. OUTSIDE OF THE BUILDING. ALL SEWER SYSTEM SHALL MEET THE REQUIRED INVERT ELEVATION SHOWN ON THE CIVIL DRAWINGS. PIPING BEYOND THIS POINT IS 23. PROVIDE TRAP SEAL PRIMER FOR FLOOR DRAIN SUBJECT TO INFREQUENT USE. SPECIFIED UNDER ANOTHER SECTION OF THE SPECIFICATION AND SHALL BE AS SHOWN ON THE CIVIL DRAWINGS. 24. ALL PLUMBING, AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS GREAT EXTENT AS POSSIBLE. ALL EXPOSED CONDUITS, PLUMBING, 7. THE OWNER SHALL MAKE ALL ARRANGEMENTS WITH UTILITY COMPANIES FOR ETC. SHALL BE INSTALLED AT LEAST 6" OFF FLOOR AND 3/4" FROM WALLS USING SERVICE AND CONNECTION AND SHALL MAKE APPLICATION FOR SERVICE AND STANDOFF BRACKETS. PERMITS AND SHALL PAY ALL FEES AND CHARGES INCLUDING THE COST OF VAULTS AND METERS. 25. PLUMBING OR PIPING CANNOT BE INSTALLED ACROSS ANY AISLE WAY, TRAFFIC AREA OR DOOR OPENING. 8. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOID INTERFERENCE WITH ELECTRICAL EQUIPMENT, MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING, 26. MULTIPLE RUNS OR CLUSTERS OF PIPELINES SHALL BE FURRED IN OR ENCASED IN SKYLIGHT, ETC. AN APPROVED SEALED ENCLOSURE. 9. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING ACCESS 27. APPROVED BACKFLOW PREVENTION DEVICES SHALL BE PROPERLY INSTALLED PANELS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN AND ELECTRICAL UPSTREAM OF ANY POTENTIAL HAZARD BETWEEN THE POTABLE WATER SUPPLY AND A LIGHTING PLAN. SOURCE OF CONTAMINATION. HOSES SHALL NOT BE ATTACHED TO A FAUCET OR HOSE BIBB UNLESS AN APPROVED BACKFLOW PREVENTER IS PROVIDED. 10. COORDINATE ALL LOCATIONS, SIZES AND ELEVATIONS OF ALL SLEEVES THROUGH WALLS, BEAMS, SLABS AND FOOTING WITH STRUCTURAL AND ARCHITECTURAL 28. ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING DRAWINGS. ALL PIPES SLEEVING THROUGH FOOTINGS SHALL HAVE A SLEEVE AGENCY. DIAMETER OF TWO PIPE SIZES OVER THE PIPE PASSING THROUGH THE FOOTING. 29. EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) INCHES 11. CONTRACTOR MUST NOT CUT, RELOCATE, COMPROMISE, DAMAGE OR OTHERWISE ABOVE THE FLOOD -LEVEL RIM OF THE FIXTURE SERVED BEFORE OFFSETTING ALTER THE ROOF STRUCTURE. THE JOISTS WHICH OCCUR THROUGHOUT ALL THE HORIZONTALLY OR BEFORE BEING CONNECTED TO ANY OTHER VENT. MECH. BAY AREAS LIKE WISE MUST NOT BE ALTERED. 30. EACH VENT SHALL TERMINATE NOT LESS THAN 10 FEET FROM, OR AT LEAST 3 FEET 12. BEFORE FABRICATION OR INSTALLATION, THE CONTRACTOR SHALL VERIFY EXACT FROM, OR NOT LESS THAN 3 FEET ABOVE ANY OPENABLE WINDOW DOOR, OPENING AIR LOCATIONS OF ALL MECHANICAL EQUIPMENT AND EQUIPMENT PROVIDED UNDER INTAKE, OR VENT SHAFT, OR NOT LESS THAN 3 FEET IN EVERY DIRECTION FROM ANY LOT ANOTHER SECTION OF SPECIFICATIONS. EXACT ROUGH -IN LOCATIONS AND LINE. REQUIREMENTS SHALL BE COORDINATED IN FIELD. 31. FIELD VERIFY ALL EXISTING PLUMBING CONDITIONS AND EXISTING/NEW HVAC 13. CONNECTION BETWEEN INCOMPATIBLE MATERIALS ABOVE GRADE AND INSIDE PLUMBING CONNECTIONS PRIOR TO BIDDING AND START OF WORK. BUILDING SHALL BE MADE WITH TWO (2) DIELECTRIC UNIONS SEPARATED BY A TWELVE INCH (12") SECTION OF RED BRASS PIPE. 32. IN THE EVENT THAT THE PLANS DO NOT REPRESENT FIELD CONDITIONS, CONTACT THE OWNER, ARCHITECT, OR DESIGNATED ENGINEER DESIGNER PRIOR TO START OF 14. ALL FLOOR AND WALL PENETRATIONS MUST BE SEALED WATERTIGHT AND VERMIN ANY WORK. PROOF. 33. CAP ALL DOMESTIC WATER PIPING THAT IS SERVING A PLUMBING FIXTURE THAT IS BEING DEMOLISHED. PLUMBING FIXTURE SCHEDULE MARK ITEM HW CW VENT WASTE DESCRIPTION F.V. TYPE AMERICAN STANDARD PRIOLO FLOWISE ELONGATED ADA COMPLIANT TOILET MODEL 3695.001 WITH WC WATER CLOSET - 1" 2" 4" OPEN FRONT TOILET SEAT, INSTALL WITH HIGH EFFICIENCY FLUSH VALVE. 1.28GPF EQUIVALENT ACCEPTABLE. INTEGRAL COUNTERTOP LAVATORY SUPPLIED BY OWNER. AMERICAN STANDARD METERING PILLAR LAV COUNTERTOP LAVATORY 1/2" 1/2" 2" 2" TAP FAUCET. 0.17 GALLON PER CYCLE. ADA COMPLIANT. EQUIVALENT ACCEPTABLE. INSTALL WITH POWERS #LFG480 MIXING VALVE(ASSE 1070 LISTED). ZURN Z415B W/SEDIMENT BUCKET. TRAP PRIMER CONNECTION WHERE REQUIRED BY CODE. FD FLOOR DRAIN - __ 2" 2" EQUIVALENT FIXTURE ACCEPTABLE. ZURN Z-1901, 12" SQUARE TOP, HALF GRATE COVER AND 8" DEEP WITH DOME STRAINER. FS FLOOR SINK - __ 2" 2" EQUIVALENT FIXTURE ACCEPTABLE. HD HUB DRAIN - - 2" 2" ZURN Z1870 HUB DRAIN, 3" DIA. INLET, 2" DIA. OUTLET. EQUIVALENT FIXTURE ACCEPTABLE. WCO WALL CLEANOUT - - - LINE SIZE ZURN Z1441 WALL CLEANOUT W/SMOOTH ACCESS COVER EQUIVALENT FIXTURE ACCPETABLE. FCO FLOOR CLEANOUT - - - LINE SIZE ZURN Z1400-B FLOOR CLEANOUT EQUIVALENT FIXTURE ACCEPTABLE. WH WATER HEATER 3/4" 3/4" - _ TWO RINNAI CU199i GAS TANKLESS WATER HEATERS. 199,000 BTU/H INPUT, 7.5 GPM @ 50°F RISE PER UNIT. APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE PLUMBING SPECIFICATION 1. CLEANOUTS PROVIDE CLEANOUTS WITH BRASS SCREW PLUG AT ALL CHANGES OF DIRECTION TO PERMIT ROUTING OF ALL SEWERS. ALL CLEAN OUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THE CONTRACTOR SHALL COORDINATE ALL CLEAN OUT LOCATIONS OF EQUIPMENT, CABINETS, ETC., WITH THE ARCHITECT PRIOR TO ANY INSTALLATION. 2. VALVES EVERY PLUMBING FIXTURE SHALL BE INDEPENDENTLY VALVED. 3. TESTING ALL SEWERS AND WATER PIPING SHALL BE PROPERLY TESTED TO THE SATISFACTION OF THE ARCHITECT AND THE LOCAL BUILDING INSPECTOR. 4. EXCAVATION AND BACK FILLING TRENCHES SHALL BE BACK FILLED AND SETTLED BY PUDDLING. NO PIPE SHALL BE LESS THAN 12" BELOW FINISH GRADE. 5. PIPING SUPPORTS ALL PIPING TO BE SUPPORTED WITH HANGERS AND BRACKETS WHICH PROVIDE ISOLATION FROM FRAMING. CONTACT BETWEEN PIPE AND SUPPORT TO BE LINED WITH PLASTIC OR FELT. PIPE INSULATION SPACE -CONDITIONING AND SERVICE WATER -HEATING SYSTEM SHALL BE INSULATED IN ACCORDANCE WITH THE FOLLOWING TABLE: PIPE INSULATION THICKNESS FLUID TEMP. RANGE (°F) CONDUCTIVITY RANGE (BTU-"/HR PER SQFT/°F) INSULATION MEAN RATING TEMP. (°F) NOMINAL PIPE DIAMETER (") <1 1 TO <1.5 1.5 TO <4 4 TO <8 8 AND LARGER INSULATION THICKNESS REQUIRED (") SPACE HEATING, HOT WATER SYSTEMS AND SERVICE WATER HEATING SYSTEMS 350< 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.31 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.22-0.28 1 100 1 1.0 1 1.5 1.5 1 1.5 1.5 SPACE COOLING SYSTEMS CHILLED WATER, REFRIGERANT AND BRINE 40-60 0.21-0.27 75 NONRES 0.5 RES 0.75 1.0 1.0 1.0 <40 0.20-0.26 50 1 1.0 1 1.5 1.5 1.5 1.5 EXCEPTIONS: (1) FACTORY -INSTALLED PIPING WITHIN SPACE CONDITIONING EQUIPMENT; (2) PIPING THAT CONVEYS FLUIDS THAT HAVE A DESIGN OPERATING TEMPERATURE RANGE BETWEEN 60 DEGREES AND 105 DEGREES FAHRENHEIT; (3) WHERE THE HEAT GAIN OR HEAT LOSS TO OR FROM PIPING WITHOUT INSULATION WILL NOT INCREASE BUILDING SOURCE ENERGY USE; (4) PIPING THAT PENETRATES FRAMING MEMBERS SHALL NOT BE REQUIRED TO HAVE PIPE INSULATION FOR THE DISTANCE OF THE FRAMING PENETRATION. METAL PIPING THAT PENETRATES METAL FRAMING SHALL USE GROMMETS, PLUGS, WRAPPING OR OTHER INSULATING MATERIAL TO ASSURE THAT NO CONTACT IS MADE WITH THE METAL FRAMING. NONRESIDENTIAL NOTES LAVATORIES IN RESTROOMS OF PUBLIC FACILITIES SHALL BE EQUIPPED WITH OUTLET DEVICES THAT LIMIT THE FLOW OF HOT WATER TO A MAXIMUM OF 0.5 GPM OR WITH SELF -CLOSING FAUCETS THAT LIMIT DELIVERY TO A MAXIMUM OF 0.2 GALLONS OF HOT WATER FOR RECIRCULATING SYSTEMS, AND SHALL BE EQUIPPED WITH DEVICES THAT LIMIT THE OUTLET TEMPERATURE TO A MAXIMUM OF 1107. A- occupancies will require a permit or letter exempting project from L and I boiler and pressure vessel department. City Of Edmonds Work Address Owner Approved Date Building Official Permit Number Building Department PLUMBING FOR REMODEL 8425 244TH ST SW ARBY'S 03/21/2023 Eris. cev� BLD2023-0298 PLUMBING FIXTURE UNITS FIXTURE TYPE NO. OF FIXTURE WATER LOAD WASTE LOAD WATER FU PER FIXTURE FIXTURE CW FU FIXTURE HW WASTE FU FU PER FIXTURE TOTAL WASTE FU (E)WATER CLOSET (F.V.) 2 5 10 4 8 (E)LAVATORY 2 1 2 2 1 2 HAND SINK 2 2 4 4 2 4 PREP SINK 2 4 8 8 INDIRECT INDIRECT SODA 1 0.5 0.5 INDIRECT INDIRECT ICE MACHINE 1 1 1 INDIRECT INDIRECT 3-COMP SINK 1 3 3 3 INDIRECT INDIRECT MOP SINK 1 3 3 3 3 3 FLOOR DRAIN 5 4 20 FLOOR SINK 5 4 20 HUB DRAIN 1 2 2 SHAKE MACHINE 1 1 1 INDIRECT INDIRECT (E)FLOOR DRAIN 1 4 4 (E)FLOOR SINK 1 4 4 TOTAL 32.5 20 67 WATER CALCULATIONS STREET PRESSURE: 60 PSI MIN. (V.I.F.) 70 PSI MAX(V.I.F.) METER SIZE: 1 INCH (V.I.F.) 44 GPM FLOW MATERIAL: COPPER TYPE L MAX VEL. (CW): 8 FPS MAX VEL. (HW): 5 FPS COLD WATER METER LOSS (PSI) 3.0 PSI BACKFLOW PREVENTER (PSI) 0 PSI PRESSURE REGULATING VALVE (PSI) 0 PSI PRESSURE HEAD LOSS (PSI)BLDG HEIGHT: 15 FT 6.5 PSI RESIDUAL PRESSURE REQUIRED (PSI) 25 PSI TOTAL LOSSES (PSI) 34.5 PSI MINIMUM WATER PRESSURE (PSI) 60 PSI PRESSURE AVAILABLE FOR FRICTION (PSI) 25.5 PSI ACTUAL LENGTH OF SYSTEM (FT) 200 FT DEVELOPED LENGTH (130% OF ITEM 9) (FT) 260 FT AVERAGE PRESSURE DROP (PSI/100 FT) [PRESSURE AVAIL. FOR FRIC./DEVELOPED LENGTH] X 100 9.8 PSI/100' PIPE SIZE CW SYSTEM HW SYSTEM TANK FU F.V. FU GPM FU GPM 1/2" 3 0 3 3 3 3/4" 12 0 9 8 7 1" 26 0 18 16 12 1-1/4" 56 13 31 28 19 1-1/2" 103 35 44 46 27 2" 1 254 132 76 119 48 2-1/2" 1 455 329 115 245 74 TANKLESS HOT WATER CALCULATION EQUIPMENT QTY. GPM TOTAL HAND SINK/LAVATORY 4 0.5 2 PREP SINK 2 2 4 3-COMP SINK 1 2 2 MOP SINK 11 21 2 TOTAL GPM: 1 10 CONNECTED GAS LOAD SCHEDULE MARK ITEM INPUT CFH QTY. TOTAL CFH WH WATER HEATER 199 2 398 WATER HEATING LOAD (CFH): 398 FRYER FRYER 1 225 1 225 COOKING LOAD (CFH): 225 TOTAL DEV. LENGTH = 60 FEET TOTAL CF 623 CONNECTED GAS NOTES 1 GAS PIPING SIZED FOR THE TOTAL CONNECTED LOAD 60 FT. FRO METER TO FARTHEST CONNECTION, WITH 0.6 SPECI FIC GRAVITY, 0.5" PRESSURE LOSS IS MIN. PIPE SIZE OF 1-1/2 INCHES. 2 GAS PIPING SHALL BE THREADED UNLESS OTHERWISE REQUIRED BY CODE. 3 GAS PIPING SHALL BE TESTED IN ACCORDANCE WITH CPC SEC. 1213.3. 4 GAS BURNING EQUIP. SHALL BE INSTALLED PER NFPA #58AND NFPA #96. RECEIVED Mar 08 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O�55818 ��`g r0 N,kJ10 M= Alq TM bVis, Copyright© 2019 by Arby's Restaurant Group V) 0 z O G 0 1 LU z zo QN 2 I..L 0 Z V) N LU O f V 00 CO L.ri M Iol_ C-4 a 0 PROJECT NUMBER: IISSUE IDATE 1. 15T PLAN CHECK PLUMBING NOTES & SCHEDULES SHEET: POOO HANG PIPE LARGER THAN 4" \Ainnn STRi 1r.T1 iRF STEEL STRUCTURE FROM TOP OF JOISTS ONLY AT PANEL POINT ALL -THREAD ROD SIDE BEAM CONNECTOR ATTACHED TO TOP CHORD OF PROVIDE COPPER C WOOD TRUSS HANGERS WHERE ADJUSTABLE BAND HANGER HANGERS CONTACT FOR PIPE 3-1/2" AND SMALLER PPER PIPE AND CAST IRON PIPE 2" AND SMALLER PROVIDE GALV. STEEL SHIELD FOR ALL INSULATED PIPE.VERIFY INSULATION THICKNESS WHEN SIZING HANGERS AND SHIELDS. aurrvrK 1: SECTION PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. z DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE as VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES. w a cn SLOPE ALL WATER PIPING SLIGHTLY TOWARD DRAINABLE LOCATIONS. HANGER N of OfSPACING LU FOR PIPE SIZES: AS INDICATED IN TABLE. CAST IRON: 10' AND WITHIN a0 V-0" OF ALL JOINTS. ROD SIZES FOR PIPE SIZE: 1/2" TO 4" = 3/8", 5" TO 8" = 112", w az p= 10" TO 12" = 5/8". LOCATE HANGERS WITHIN V-0" OF VALVES AND FITTINGS. PROVIDE SUPPLEMENTAL STEEL STRUTS BETWEEN JOISTS IF REQUIRED. 1/2" 6' LOCATE HANGERS WITHIN V-0" OF EQUIPMENT CONNECTIONS. ANCHOR WATER 3/4" 6' PIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY. CHAINS AND 1" 6' PERFORATED STRAP IRON AND STEEL ARE NOT ACCEPTABLE. DO NOT 1-1/4" 6' SUSPEND PIPE FROM JOIST BRACING MEMBERS. REFER TO CODES AND 1-112" 6' SPECIFICATIONS FOR FURTHER INFORMATION. PROVIDE SEISMIC BRACING AS 2" 10' REQUIRED BY LOCAL AUTHORITIES. PROVIDE FIBERGLASS INSULATION WITH ALL -SERVICE JACKET WITH VAPOR BARRIER ON ALL SIZES OF HOT AND COLD WATER AND CONDENSATE PIPING. GAS PIPING SHALL BE KEPT A MIN. OF 6" ABOVE GRADE OR STRUCTURE. PIPE HANGER DETAIL (BELOW ROOF) PROVIDE SCREWED COUNTER -SINK BRONZE PLUG FOR CLEANOUT TEE WITH TAPPED THREAD & TEE JOINT COMPOUND INSTALL ESCUTCHEON PLATE AT CLEANOUT TEE. CONCRETE FLR. RISER LENGTH AS REQUIRED WASTE OR VENT TO ABOVE PLUMBING WALL OR COLUMN REFER TO FLOOR PLANS PROVIDE WATERPROOFING DIRECTION LONG SWEEP AT OF FLOW END OF LINE OR COMBINATION WYE AND EIGHTH BEND IN RUN OF LINE. NOTE: PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES NOT SERVED WITH A FLOOR CLEANOUT: LOCATED ABOVE FIXTURE FLOOR RIM WITHIN 4'-0" OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. WALL CLEANOUT DETAIL EXTERIOR WALL WALL EXHAUST AND INTAKE CAP (TYPICAL) T&P W TERMINF TO OUT (TYPI DRAIN VALVE (TYPICAL) SHUTOFF VALVE (TYPICAL) SCALE N.T.S PIPE INSULATION INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS PIPE INSULATION PROTECTION SHIELD. USE 16 GAUGE SHEET STEEL, 2 PIPE DIAMETERS LONG, 120 DEGREES SUPPORT. OR GRINNEL FIGURE 167. GAS PIPE SUPPORT STEEL PIPE, S SPACING OF NOMINAL SIZE OF SPACING TUBING OF NOMINAL SIZE OF SUPPORTS SMOOTH -WALL SUPPORTS( PIPE (INCHES) (FEET) (INCHES O.D.) FEET) 1/2 6 1/2 4 3/4 OR 1 8 5/8 OR 3/4 6 1-1/4 OR LARGER 7/8 OR 1 (HORIZONTAL) 10 (HORIZONTAL) 8 1-1/4 OR LARGER EVERY FLOOR 1 OR LARGER EVERY (VERTICAL LEVEL (VERTICAL) FLOOR LEVEL ELMDOR/STONEMAN, MODEL — #1100-4 SEALANT SHALL BE APPLIED AROUND PIPE OPENING THRU COUNTER FLASHING SLEEVE FOR WATER TIGHT SEAL APPLY PERMASEAL WATER PROOFING COMPOUND AROUND PIPE, COUNTER FLASHING SLEEVE & FLASHING FOR WATER TIGHT SEAL. SEAMLESS LEAD FLASHING OVER STEEL REINFORCED BOOT BUILT-UP ROOFING 4 1 PIPING THRU ROOF DETAIL IF WATER HEATER IS INSTALLED HIGHER THAN THE FIXTURES THAT IT SERVES, A VACUUM RELIEF VALVE MUST BE PROVIDED. GAS CW SUPPLY HW SUPPLY EXPANSION ET TANK TYPICAL INDOOR TANKLESS WATER HEATER DETAIL G :7 SCALE N.T.S 7 SCALE N.T.S PIPE THRU ROOF INSTALL (3) VANDAL -PROOF SETSCREWS mkTAll►1111 BOOT HEIGH 5" MIN. 12" MIN. 8" MIN.I SCALE N.T.S 0 FROM CW SUPPLY TO HEATER,NO INTERVENING VALVES WELDED STEEL EXPANSION TANK WITH POLYPROPYLENE LINING, FDA APPROVED FOR DOMESTIC WATER SERVICE SEISMIC STRAPPING FOR BRACING IN SEISMIC AREAS FILL TANK WITH AIR PRESSURE TO MATCH WATER PRESSURE, THEN OPEN VALVE PIPE UNION: DIELECTRIC IF REQUIRED FOR DISSIMILAR METALS BUTYL DIAPHRAGM PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED. EXPANSION TANK DETAIL TO GREASE WASTE 3-COMP SINK RIGID CONNECTION. 2" 1" AIR GAP. LOOR SINK 5 1 3-COMPARTMENT SINK DETAIL CW ABV CLG SCALE N.T.S 2 TRAP PRIMER DETAIL FINISHED FLOOR. SCALE N.T.S 6 1/2" CW TRAP PRIMER LINES IN WALL (TYPE'L' COPPER) SCALE N.T.S 3 RECEIVED Mar 08 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0, ,ass 818 ��sjoxn� Copyright92019 by Arby's Restaurant Group v l 0 z 0 0 z zo QLU rvo Z 1 � _ v 1 � Uj re [-- 0 Ln R::I- (V fV 0000 CO Li') Clr � Q 00 PROJECT NUMBER: ISSUE DATE 1. 1ST PLAN CHECK PLUMBING DETAILS SHEET: Pool Rinnai. ■ FLEXIBLE VENTING OPTIONS • Concentric or Schedule 40 PVC/CPVC • Direct Vent (Concentric and Twin Pipe) • Non -Direct Vent (Room Air) • Common Vent (Direct Vent and Room Air) Vent lengths up to 150 ft with eight Tankless Water Heater units. • Maximum Equivalent Vent Lengths: Twin Pipe Vent Sizes 2 in. (51 mm) 3 in. (76 mm) Vent Lengths 65 ft (20 m) 150 ft (46 m) Concentric Vent Sizes 2 in. X 4 in. 3 in. X 5 in. Vent Lengths 65 ft (20 m) 150 ft (46 m) ■ EASE OF INSTALLATION AND SERVICEABILITY • Compact Design to Save Space • Wi-Fi Technology for Remote Monitoring and Management • Sliding Mounting Bracket for Easy Installation • Simple Gas Conversion ■ OPTIONAL ACCESSORIES Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Recess Box, Recirculation Pump, DPS/MIS Switch, EZConnect`"' Cables, Cascade Cables, control•rT"° Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories. COMMERCIAL SUPER -HIGH -EFFICIENCY (CONDENSING) TANKLESS WATER HEATER Installation Type Internal (Indoor) Commercial Applications Model Numbers CU199i (REU-N3237FFC-US) CU160i (REU-N2530FFC-US) Approved Gas Types Natural and Propane UEF up to 0.93 Thermal Efficiency: Up Efficiency Ratings not certified to 97% by AHRI EF: 0.96 (CU199i) 0.95 (CU160i) High Altitude Approved Up to 10,200 ft (3,109 m) Water Flow Control Water Flow Sensor, Electronic Water Control and Bypass Control Controller Standard: Integrated Controller Optional: MC-91-2US Certifications AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR° Warranty • Heat Exchanger: 8 years or 12,000 operation hours, whichever occurs fi rst • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year Safety Devices Flame Failure- Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase Tankless Water Heater, Wall Mounting Bracket, Pressure Relief Valve and Adapter, Isolation Valve Kit, Vent Screens (x2), Vent Screen Screws (x2), and Self -Tapping Screws (x2) Additional Features • Complies with South • Ultra Low NOx Coast Air Quality • Tankless Rack System- Compatible Management District 14 ng/J or 20 ppm • 1/2 in. (13 mm) Gas Line Compatible NOx Emission Levels COMMERCIAL APPLICATIONS Commercial Tankless Demand Duo'" Rack Systems Commercial Hybrid System I Ll S �- co - ESIG SP ' C US ceanEieo Fao® LOW LEAD SANITATION Tle CONTENT CERTIFIED TO ANSI Z21.10.3 - CSA 4.3 RINNAI_US • 1-800-621-9419 A- occupancies will require a permit or letter exempting project from L and I boiler and pressure vessel department. OR In M N O N O N N SPECIFICATION CU199i CU160i Dimensions - w, h, d 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) Minimum Gas Consumption Btu/h 15,000 Maximum Gas Consumption Btu/h 199,000 160,000 Flow Rate' 0.26 - 9.8 GPM 0.26 - 8.0 GPM (Min - Max) (1.0 - 37 L/min) (1.0- 30 L/min) Max Flow Rate with 11 GPM 9 GPM Parameter Adjustment (42 L/min) (34 L/min) Weight 64 lb (29 kg) 62 lb (28 kg) Sound Level 49 dB 48 dB Normal 84 W 52 W Standby 1.3 W Freeze Protection 148 W v L,, Max Current 4 Amps Fuse 10 Amps • Minimum: 98° F (37° C) Default Temperature • Maximum: 140° F (60° C) Default 185° F (85° C) With Parameter Adjustment By -Pass Flow Control Electronic Gas Supply Pressure' • Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c. Ignition System Direct Electronic Ignition Electronic Connections • Appliance: AC 120 Volts, 60Hz. • Temperature Controller: DC 12 Volts (Digital) Water Supply Pressure • Minimum: 50 PSI (Recommended 60-80 PSI for max performance) a Maximum: 150 PSI Controller Cable Non -Polarized Two Core Cable (Minimum 22 AWG) • Gas Supply: 3/4 in. (19 mm) NPT Service Connections • Cold Water Inlet: 3/4 in. (19 mm) NPT • Hot Water Outlet: 3/4 in. (19 mm) NPT • Condensate Drain: 1/2 in. (13 mm) NPT • Top: 2 in. (51 mm)* • Back: 0 in. Clearances • Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** • Front: 0 in.** • Vent: 0 in. * 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). Z The maximum gas supply pressure must not exceed the value specified by the manufacturer. Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. 12 hIf1TC• RA-;-.- fl-, 0 zs so zs too izs >so Delta T-Temperature Rise (°F) in. (mm) FRONT 5.90 (150) ov v OM co W o� _ o, � O M 'o N_ Mu .g, e e 18.5 (470) SIDE 6.08 (1541 Vent Connection: 2 in. (51 mm) nominal PVC/ Polypropylene or 3 in./5 in. Concentric. Cd N N � (290) � (290) BOTTOM a all Mir a O° (XiLD US A B IT C E D F G Connection in. mm COLD F 9.54 242 C 3.56 90 HOT H 14.27 362 B 6.16 156 GAS E 3.57 91 D 2.78 71 PRV G 10.39 264 A 7.60 193 Rinnai America Corporation • 103 International Drive, Peachtree City, GA 30269 • 1-800-621-9419 • rinnai.us CUi-SP-4 ©2020 Rinnai America Corporation. Rinnai America Corporation continually updates materials, and as such, content is subject to change without notice. 12/2020 N Series Condensing Local, state, provincial, federal and national fuel gas codes must be adhered to prior to and upon installation. Commercial Indoor Spec Sheet RECEIVED Mar 08 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT oSUN q 0 0, , 5581 8�b �Sj�N'AL�� R MIML ARTM Copyright©2019 by Arby's Restaurant Group V 1 r) z cO G W r) � z zo � Q� oc Q� �Ln W o (� � f V 00 (V 00 CO In � I IL.I� � Q Q 00 PROJECT NUMBER: ISSUE DATE 1. 1ST PLAN CHECK PLUMBING SPECIFICATION SHEETS SHEET: P002 un M M N O N O N N WASTE & VENT PLAN xSS xSS xSS ) 10 (E) 4" W; MIN. 1/8" PER 1' SLOPE RECEIVED Mar 08 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 KEYED PLAN NOTES: 1. P.O.C. TO EXISTING 4" SANITARY WASTE WITH NEW PIPING. FIELD VERIFY ALL EXISTING CONDITIONS, SIZE, AND LOCATION PRIOR TO START OF THIS WORK. 2. P.O.C. TO EXISTING 2" VENT WITH NEW PIPING. FIELD VERIFY ALL EXISTING CONDITIONS, SIZE, AND LOCATION PRIOR TO START OF THIS WORK. 3. P.O.C. TO EXISTING 1-1/2" VENT WITH NEW PIPING. FIELD VERIFY ALL EXISTING CONDITIONS, SIZE, AND LOCATION PRIOR TO START OF THIS WORK. 4. INSTALL NEW 2" VENT THRU ROOF. FIELD VERIFY LOCATION PRIOR TO START OF THIS WORK. 5. WATER HEATER T&P VALVE DRAIN TO HUB DRAIN. 6. ROUTE 3/4" WALK-IN COOLER/FREEZER CONDENSATE DRAIN LINE AS HIGH AS POSSIBLE AND ALONG WALLS AS SHOWN. INSULATE ALL CONDENSATE PIPING AND PITCH A MIN. OF 1/4" PER FOOT IN THE DIRECTION OF FLOW. SEAL ALL COOLER WALL PENETRATIONS WATER TIGHT AND COVER EACH WITH AN ESCUTCHEON PLATE. PROVIDE FULL SIZE TRAP AND EXTEND ABOVE FLOOR AND BEHIND EQUIPMENT FOR AN INDIRECT CONNECTION TO A NEARBY FLOOR SINK. 7. PREP SINKS, ICE MAKER, SHAKE MACHINE, AND SODA MACHINE INDIRECTLY DRAIN TO ADJACENT FLOOR SINKS. INSTALL FLOW CONTROL DEVICE FOR PREP SINK. 8. 3-COMP, FLOOR DRAIN, FLOOR SINKS, MOP SINK, AND HAND SINK DIRECTLY DRAIN INTO GREASE INTERCEPTOR AND CONNECT TO SEWER LINE. INSTALL FLOW CONTROL DEVICE FOR 3-COMP. 9. INSTALL 3" EXHAUST/INTAKE CONCENTRIC VENT TO ROOF PER MANUFACTURER'S INSTRUCTION. 10. CONTINUATION TO EXISTING SANITARY SEWER. FIELD VERIFY ALL EXISTING CONDITIONS, SIZE, AND LOCATION PRIOR TO START OF THIS WORK. 11. CONTINUATION TO FUTURE GREASE INTERCEPTOR. GENERAL NOTES: 1. IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION, CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATION REFLECTING ACTUAL CONDITIONS. 2. ALL PLUMBING FIXTURES AND CONNECTIONS ARE NEW UNLESS NOTED AS EXISTING. 3. COORDINATE FLOOR SINK AND DRAIN LOCATIONS, IF ANY, WITH ARCHITECTURAL AND FOOD SERVICE PLAN PRIOR TO ROUGH -IN. 4. ALL UNDERGROUND WASTE PIPING SHALL BE SLOPED AT A 2% GRADE UNLESS OTHERWISE NOTED. 5. PROVIDE WALL CLEAN OUTS TO ALL LAVATORY, HAND SINK AND URINAL FIXTURES. U c� �::i 00 4_j N c� o� tp a- U O o �o O �a 0 UW�o tnm AR TM b % S Copyright©2019 by Arby's Restaurant Group v J z O G LU 0 � z zo Q 2 rvo LL 0 D N v 1 � LU O Tt O fV 00 �W Lf) ar) I..I� � Q 00 PROJECT NUMBER: ISSUE DATE 1. 1ST PLAN CHECK WASTE & VENT PLAN SHEET: P100 Ln M M N O N O N N WATER & GAS PLAN RECEIVED Mar 08 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 KEYED PLAN NOTES: 1. P.O.C. TO EXISTING CW LINE WITH NEW PIPING. FIELD VERIFY ALL EXISTING CONDITIONS SIZE AND LOCATIONS PRIOR TO START OF THIS WORK. 2. P.O.C. TO EXISTING HW LINE WITH NEW PIPING. FIELD VERIFY ALL EXISTING CONDITIONS SIZE AND LOCATIONS PRIOR TO START OF THIS WORK. 3. P.O.C. TO EXISTING GAS LINE WITH NEW PIPING. FIELD VERIFY ALL EXISTING CONDITIONS SIZE AND LOCATIONS PRIOR TO START OF THIS WORK. 4. RELOCATED GAS METER W/ MAIN GAS SHUT-OFF VALVE. FIELD VERIFY ALL CONDITIONS AND LOCATIONS PRIOR TO START OF THIS WORK. 5. INSTALL SHAKE MACHINE, SODA DISPENSING MACHINE, ICE MACHINE WITH BACKFLOW PREVENTER. 6. INSTALL MOP SINK W/ VACUUM BREAKER. 7. PROVIDE 1/2" TRAP PRIMER FOR FLOOR DRAIN. 8. INSTALL WATER HEATER WITH NEW PIPING. FIELD VERIFY LOCATION AND SIZE BEFORE START OF WORK. SEE PLUMBING SCHEDULE ON P000 AND P001, RESPECTIVELY. 9. CONTINUATION TO EXISTING WATER METER. FIELD VERIFY ALL EXISTING CONDITIONS, SIZE, AND LOCATIONS PRIOR TO START OF THIS WORK. GENERAL NOTES: 1. IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION, CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATION REFLECTING ACTUAL CONDITIONS. 2. ALL PLUMBING FIXTURES AND CONNECTIONS ARE NEW UNLESS NOTED AS EXISTING. U c� S~ Oc ct a� U O o �o ct ;4 O H v I~ 0 UW�o aSUN 55818 *tI.sjox�.���1 b mn AR TM S Copyright© 2019 by Arby's Restaurant Group z O G c 1 LU Q � z zo QN 5 C)r c) D Q LU O O N 00 m Lr) Ol I..I� rj Q Q 00 PROJECT NUMBER: JISSUE JDATE 1. 1ST PLAN CHECK WATER & GAS PLAN SHEET: P200