REVIEWED BLD2022-1685+STRUCTURAL+12.12.2022_8.47.08_PM+3265278PLAN INSTRUCTIONS READ THIS FIRST These plans are organized so that more detailed or specific information is found in the same way by following the direction shown below: GENERAL STRUCTURAL NOTES SCHEDULES, DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES for more specific information. SCHEDULES DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES and SCHEDULES for more specific information. DETAILS PLANS will often refer to GENERAL STRUCTURAL NOTES, SCHEDULES and DETAILS for more specific information. PLANS See the SYMBOL LEGEND as well as ABREVIATIONS AND ACRONYMS for other additional information used on the PLANS. The term, TYPICAL (or TYP), used with a detail callout or plan note, indicates that the information specified shall apply in all similar conditions. IF YOU HA VEANY QUESTIONS OR CONCERNS CONTACT US IMMEDIA TEL Y.i We can be reached immediately by phone: (425) 778-1023 For less pressing questions, email us: inbox@ssseng.com Please help us get to your plans by having this job number handy: s2208008 ABBREVIATIONS AND ACRONYMS ABV ABOVE E.S. EACH SIDE O.C. ON CENTER A.B. ANCHOR BOLT E.W. EACH WAY P.T. PRESSURE TREATED BLW BELOW EA EACH REINF REINFORCEMENT BLK BLOCK E. N. EDGE NAILING REQD REQUIRED BLKG BLOCKING EMBED EMBEDMENT SCHED SCHEDULE B.N. BOUNDARY NAILING EXIST EXISTING SIM SIMILAR BTM BOTTOM FDN FOUNDATION STD STANDARD BRIG BEARING FLR FLOOR STRUCT STRUCTURAL BTWN BETWEEN FRMG FRAMING SW SHEARWALL CLR CLEAR FTG FOOTING THRU THROUGH CLTR COLLECTOR G.T. GIRDER TRUSS T.R. THREADED ROD CONIC CONCRETE GR GRADE TYP TYPICAL CONN CONNECTION HORIZ HORIZONTAL U.N.O. UNLESS NOTED CONT CONTINUOUS MAX MAXIMUM OTHERWISE CTR CENTER MFG MANUFACTURED VERT VERTICAL DBL DOUBLE MIN MINIMUM w/ WITH DET DETAIL o/ OVER w/o WITHOUT E. E. EACH END oc ON CENTER W.W.F. WELDED WIRE FABRIC DESIGN CRITERIA Governing Code 18 IBC Risk Category H Wind Design Data Basic Wind Speed (3 sec gust) mph 98 Surface Roughness B Wind Exposure Category C Earthquake Design Data Seismic Importance Factor, Ie 1.00 Site Classification D Short Period Acceleration, SS 1.298 1-Second Acceleration, S1 0.458 Seismic Design Category D Spectral Response Coefficient, Sps 1.038 Spectral Response Coefficient, Sol 1 0.562 Gravity Load Data Internal Pressure Coefficient +/- 0.18 Topographic Factor, KZt 1.00 Ground Elevation Factor, Ke 0.99 Seismic Force Resisting System ITable 12.2-1: A-15 2016 Equiv. Lateral Force Procedure Response Modification Factor, R 6.5 6.5 Transverse Longitudinal Seismic Response Coefficient, CS 0.160 0.160 Transverse Longitudinal Seismic Base Shear, V 0 Ibs loads are psf Dead Live Snow Rafters' *Pitches < 8:12 15 0 25 Decks: loads are psf Dead Live Snow Joistss 20 60 25 Notes apply as called out in table above. 1 Rafters of sawn lumber or wood I -joists. 5 Joists of sawn lumber or wood I -joists. Assumed Soil Data Allowable Soil Bearing 2000 psf The following documentation shall be available on ' site for the building inspector: = 0 COE APPROVED ARCHITECTURAL PLAN SET ' 1 COE APPROVED STRUCTURAL PLAN SET 1 COE REVIEWED CALCULATION PACKET ■❑ ENERGY CREDIT WORKSHEET '■ 1 - F—] SITE PLAN • ■ F-1 CIVIL PLAN i ■ F-1 1 1 ■ 1 ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 GENERAL STRUCTURAL NOTES CODE All conditions, materials and construction shall conform to the code specified in the DESIGN CRITERIA, or other codes required by the governing jurisdiction. PROTECTION Through maintenance and current best practices, provide a building envelope that will preserve the integrity of the structure throughout it's lifetime. INSPECTIONS Notify Building Department for inspections required by local jurisdiction. FOUNDATIONS AND RETAINING WALLS Extend footings to undisturbed bearing soil. Do not backfill until all slabs and/or horizontal diaphragms are constructed, otherwise provide temporary bracing to resist movement. See applicable detail(s): FTG DF CONCRETE f'c = 3000 psi minimum for environmental exposure (2500 psi used in structural design, or unless greater psi indicated on the plans). 5 1/2 sacks of cement per cubic yard of concrete and a maximum of 6 gallons of water per 94 lb sack of cement. Maximum slump is 4". Segregation of materials shall be prevented through proper handling and placement. REINFORCING STEEL #4 bars and larger shall be Grade 60 deformed bars, and #3 bars shall be Grade 40 (u.n.o.), in accordance with ASTM A-615. Lap splices 32 bar diameters u.n.o. Welded wire fabric shall conform to ASTM A-185 and shall be 6x6 - W1.4xW1.4. Lap one full mesh at splices. CLEAR COVER 3" clr when cast against Earth and 2" clr in all other locations, u.n.o. WOOD FRAMING in contact with concrete or masonry, or exposed to weather, shall be pressure treated. Numbers in parenthesis, IE (1-1), refer to corresponding engineering calculations. CONNECTORS AND FASTENERS Fasteners, including nuts and washers, and connectors in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. EXCEPTION: Plain carbon steel fasteners, including nuts and washers, in SBX/DOT and zinc borate preservative treated wood in an interior, dry environment shall be permitted. SOLID SAWN LUMBER shall meet the following minimum grades (u.n.o.) conforming to "WWPA GRADING RULES FOR WESTERN LUMBER", latest edition: BEAMS, POSTS, RAFTERS, JOIST 6X and wider DF#1 WALL STUDS 2x HF#2 ENGINEERED WOOD shall meet the following minimum properties: Callout E x 106 (psi) Fb(psi) Fc par (psi) Fc perp (psi) Fv(psi) LSL 1.55E 1900 2050 900 310 CONNECTIONS and fasteners shall be per CODE Table 2304.10.1 u.n.o. The symbol, #", indicates a hardware connector from the most current Simpson Strong -Tie Catalog. Hardware with equivilent or greater capacities from other manufacturers may be substituted, example you can use USP's Dual Specification Chart to make an equivilent or greater capacity selection. Install per the manufacturer instructions. Fasteners and hardware in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. NAILS All nails shall be "Standard Common" size per the latest edition of the National Design Specification for Wood Construction (NDS) u.n.o. POST CAPS Provide a post cap on isolated columns that most nearly matches the actual member size(s) U.N.O. Each connection shall have a minimum of (3)10d to the post and (3)10d to the beam. JOBSIITE SAFETY Sound Structural Solutions Inc has not been retained or compensated to provide design and/or construction review services related to the contractor's safety precautions or to means, methods, techniques, sequences or procedures for the contractor to perform their work. The undertaking of periodic site visits by the ENGINEER shall not be construed as supervision of actual construction and not make him responsible for providing a safe place for the performance of work by the contractor, subcontractors, suppliers or their employees, or for access, visits, use work, travel, or occupancy by any person. OWNERSHIP OF DOCUMENTS These drawings and calculations are the intellectual property of Sound Structural Solutions Inc. These drawings may not be used in whole or in part by any person without permission of Sound Structural Solutions Inc. MISCELLANEOUS The contractor shall verify dimensions and conditions at job site. The contractor shall provide temporary bracing as required until all permanent connections and stiffenings have been installed. Do not scale drawings. Pre -fabricated items to be handled and installed per manufacturer's recommendations. EXISTING CONDITIONS THE FOLLOWING FRAMING ASSUMPTIONS WERE MADE IN OUR DESIGN ; • SPAN DIRECTION AND CONSTRUCTION OF ROOF AND FLOOR FRAMING • SIZE AND SPACING OF EXISTING RIM AND FLOOR JOISTS • PRESENCE OF STEM WALL AND FOOTINGS THESE ARE REASONABLE ASSUMPTIONS BASED ON PHOTOGRAPHS, DESIGNER DOCUMENTATION AND TYPICAL CONSTRUCTION STANDARDS. IT WILL BE NECESSARY, HOWEVER, TO VERIFY THESE ELEMENTS DURING DEMOLITION WHEN FURTHER OBSERVATIONS CAN BE MADE. THIS OFFICE IS AVAILABLE TO PARTICIPATE SHOULD THE SITUATION BECOME COMPLICATED. THE STRUCTURAL MEMBERS AND ASSEMBLIES SHALL BE CONSTRUCTED AS SPECIFIED ON THE PLANS. EXISTING CONSTRUCTION IS ADEQUATE WHERE IT MEETS OR EXCEEDS THE MATERIAL GRADES AND SPECIFICATIONS WE PROVIDED THROUGH PLANS, DETAILS AND GENERAL NOTES. WHERE EXISTING CONDITIONS OR OUR PROPOSED CONSTRUCTION DIFFERS, THEN, EITHER CONSTRUCT AS SHOWN ON OUR PLANS OR CONTACT THIS OFFICE TO DISCUSS OPTIONS. 2x10 BLOCK EACH SIDE • JOIST (5) 10d NAILS A EACH SIDE & POST, MA' EACH POST POST AB( INTERIOR POST CONNECTION N.T.S. "O THREADE #HTT4 w/ (18) DECK FIGURE 502.2.2.3 EXISTING HOUSE - - DALL I DECK ATTACHMENT FOR LATERAL LOADS NAILING TO JOIST IN N.T.S. DALLA SOLID RIM DECKING BY OTHERS LEDGER ELEV. CTR OF RIM 8" TYP. 8" TYP. 1" MIN. 16" 0.22"4 x 4" #SDWS 2" MAX. TYP, SCREWS @ 8" oc 2x(MATCH JOIST) P.T. LEDGER EXTERIOR DECK LEDGER N.T.S. %" 4 GALV M.B. OR THREADED ROD w/ NUTS & WASHERS (2) #DTT2 w/ A (8) % x 1 % #SDS ea Y" 4 GALV M.B. OR THREADED ROD w/ NUTS & WASHERS (2) #DTT2 w/ B (8) % x 1 % #SDS ea EXISTING HOUSE ~� EDLA 4x4 MIN. POST @ 6-Toc MAX, TYP 2x8 (MIN) BLKG 2" 2" (2) #DTT2 w/ (8) % x 1 % #SDS ea TESTED POST -TO -DECK ASSEMBLY BY SIMPSON STRONG -TIE PUBLISHED IN REPORT (T-C-GRDRLPST20) HOLDOWN GUARDRAIL POST APPLICATION N.T.S. HGP X" 4 x 6" SDS SCREW [E] RIDGE BEAM ONE SIDE, ALTERNATE SIDE AT EACH RAFTER [E] RAFTERS [N] RIPPED 40, BEVEL TO MATCH [E] RAFTERS #A35F EACH SIDE @48" oc [N] RIDGE BEAM EXISTING RAFTER TO RIDGE N.T.S. DIMENSIONS ASSUMED IN DESIGN VERIFY DURING CONSTRUCTION CONCRETE 8'-0" MAX BASEMENT WALL CONCRETE FOOTING 8" MIN 16" MIN REM I REMODEL VERIFICATION N.T.S. REM FOOTING DIAMETER POST 8" MIN CONCRETE FOOTING 18" MAX FINISH GR BRG SOIL I DECK BEAM FOOTING N.T.S. \ 0_1 A 12" MIN FOOTING SCHEDULE CENTER UNDER CONCENTRATED LOAD U.N.O. FOOTING SIZE REINFORCEMENT ID WIDTH (Transverse) I LENGTH I (Longitude) THICKNESS LONGITUDE TRANSVERSE F1.3m V-4" DIAMETER See DF None None F2m 2'-O" DIAMETER See DF None None F2.5 2'-6" 2'-6" 10" (3) #4's (3) #4's LONGITUDE REINF TRANSVERSE REINF pf1ST Tn FT(; / \ THICKNESS LENGTH WIDTH (LONGITUDE) (TRANSVERSE) PLYNTH ON FTG FOOTING, TYPICAL N.T.S. DF FTG @ WALL FTG @ WALL CORNER FTG UNDER SLAB ON GRADE FTGC SSS Number: s2208008 Project Name: 8219 Sierra Drive Owner: The Little Group Project Location: 8219 Sierra Drive, Edmonds, WA M Z O H 0 J W t� (V J W z E O ~ U V � OC � Ln p z Z 7 o w O U Cn c a� v7 O C �A_DVS WA 0' IONAL This space reserved for governing jurisdiction stamps BLD2022-1685 RECEIVED Dec 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 11/8/2022 REVISED: ---S1 - V-3" MAX (5) POSTS @ 8'-0" oc MAX SYMBOL LEGEND SLEXP ------------------- DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM. BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 2-2x6 at dropped condition u.n.o. JAL U1 HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL STRUCTURAL NOTES for the minimum size hanger. If a different model no. is required, it will be noted on the plan. JOIST, TRUSS, OR RAFTER Repetitive member symbol points in the direction of the span. The type, size and max spacing between members will be indicated in bold type with a symbol which is representative of the layout of the entire level. POST Indicates the location of a post within walls below framing. Sizes are indicated on the plan. Grades are indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BHS for posts not indicated on the plans. F- —1 F2 SPREAD FOOTING See CONCRETE and REINFORCING BAR specifications per DETAIL FTG & DF. L_ _ J EXISTING CONCRETE WALL AND CONTINUOUS FOOTING See assumed design parameters per DETAIL REM. DROP BEAM _ I DROP BEAM I _ DROP BEAM _ DROP BEAM w a �o o a ohe z dy Q J V LU V � w a� N EDL N (9� 2x P.T. LEDGER DALL 6x6 w/ #CS16 @ TOP E.S., 11" MIN END LENGTH w/ 10d NAILS [N] 3-20 STUDS #ABU @ BTM 3-1 % x 18 LSL RIDGE BEAM (1-1) STORAGE FIRST FLOOR FRAMING PLAN 1/4" = V-0" F20 / 1 F1.30 F1.30 I I I I I I I I I I I I I I I I I I I I I I I I I F240 � 1 AS REQTD TO NOT DISTURB (5) POSTS @ 8'-0" oc MAX F240 TYP DF BASEMENT AND FOUNDATION PLAN 1/4" = V-0" EX, LU w lZ Z 4A P.T. POST (MAX HEIGHT OF 8'-6") w/ #PCZ @ TOP #ABU @ BTM N (TYP 7 PLCS) F sIM EDL L 6x6 w/ #CS16 @ TOP E.S., 11" MIN END LENGTH w/ 10d NAILS — IPC 3-11/4 x 18 LSL RIDGE BEAM (1-2) F240 F240 V-0" MAX /— FRAMING ABOVE ETR TYP NOTE: THIS IS A SCHEMATIC REPRESENTATION OF THE BUILDING. THE DIMENSIONS AND FRAMING LAYOUT IS A REPRESENTATION ONLY. DO NOT SCALE OR UTILIZE THIS FOR ANY PURPOSE BEYOND THE DECK CONSTRUCTION OR BEARING WALL REMOVAL OF THE SECOND FLOOR. MASTER BEDROOM [N] 3-20 STUDS 3-1 a x 18 LSL RIDGE BEAM (1-3) DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS NOTE: THIS IS A SCHEMATIC REPRESENTATION OF THE BUILDING. THE DIMENSIONS AND FRAMING LAYOUT IS A REPRESENTATION ONLY. DO NOT SCALE OR UTILIZE THIS FOR ANY PURPOSE BEYOND THE DECK CONSTRUCTION OR BEARING WALL REMOVAL OF THE SECOND FLOOR. DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS SSS Number: s2208008 Project Name: 8219 Sierra Drive Owner: The Little Group Project Location: 8219 Sierra Drive, Edmonds, WA M C/7 N Z V) O H 0 J W LPG Lon N J W Z E O V H 0) Ln C Z Ln c� 0 U p1 a� Ul Ln V) O C �Q wA' 21 This space reserved for governing jurisdiction stamps RECEIVED Dec 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 11/8/2022 REVISED: ---S2 -