CITY OF EDMONDS
121 5TH AVENUE NORTH -EDMONDS, WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
STATUS:- ISSUED 06/07/2019 Pennit#: BLD20181101
BUILDING PERMIT
Expiration Date: 06/08/2020 Project Address: 15712 72ND AVE W, EDMONDS
r
Parcel No: 00513100002411
PROPERTYOWNER APPLICANT —CONTRACTOR
AN41T SHARMA JARED UNDERBRINK
1737A NW 60TH ST 250 4TH AVE S G2 Contracting LLC
SEATTLE, WA 98107 EDMONDS, WA 98020 T n
(425) 280-8457
(425) 778-8500
JOB DESCRIPTION
NEW SFR, Plumbing and Mechanical Included
VALUATION: $782,753
y rasseth
3405 172nd St #5 Box 245
Arlington, WA 98223
425 531-1747
L
PERMIT TYPE: Residential
PERMIT GROUP� 64 - Single Family Residence New,
GRADING: N CYDS: 0
TYPE OF CONSTRUCTION VR
RETAINING WALL ROCKERY:
OCCUPANT GROUP- R-3
OCCUPANT OAD�
FENCE: 0 X 0 FT.)
CODE 2015 IRC
OTHER: ------- OTHER DESC:
]ZONE: RS-20
INUMBER OF STORIES: 3
NESTED DATE-
INUMBER OF DWELLING UNITS: I
ILOT 4
EXIS'11ING ARLA
BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR 0
PRO POSIED ARI-A
BASEMENT 1680 1 ST FLOOR: 2484 2ND FLOOR
1770
3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER 0
3RD FLOOR: 0 GARAGE: 868 DECK: 2683 OTHER: 0
BEDROOMS: 0 BATHROOMS 0
BEDROOMS 5 BATHROOMS- 7
FRONTSETBACK SIDESETBACK REkRSETBACK
REQUIRED. 25'E PROPOSED. 27'7�_ REQUIRED I 0735'N PROPOSED: 17-77—REQUIRED. 25'W PROPOSED: 28'W
HEIGHT ALLOWED:O PROPOSED.0 IREQUIRED: 10735'S PROPOSED� 38'S
SETBACK NOTES:
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO
PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION
INSURANCE AND RCW 18:27.
"SAPPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
el 6, / 7 A
Print Name
Released By
Date
ATTENTION
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED. UBC 109/ IBCI 10/ IRCI 10.
= FIRE = APPLICANT = ASSESSOR = CITY
, gv�
"Iftft
Qk
STATUS: ISSUED
BLD20181101
• Installation, use and maintenance of equipment and components shall be per manufacturer's specifications, installation
instructions, and applicable state codes. Provide manufacture's installation instructions on site for Building Inspector.
• Maximum Height 25 feet. The agent/contractor shall set up the equipment; establish the datum point and the point of average
grade. Call for inspection to verify. These items must be consistent with the approved plan. If the proposed height of a
building (as shown on the plans) is within 12 inches of the ma)dmurn height permitted for the zone an elevation survey is
required.
• Special inspections have been called for soils, concrete and HS bolts on this project and are noted on the approved
construction plans.
• Submit all special inspection reports to the City Building Inspector on a weekly basis.
• Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Check thejob card for all required City inspections including final project approval and final
occupancyinspections.
• Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable.
• Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
• Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the
noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this pen -nit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRKIATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRKIB/VAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT
TIME LIMIT: SEE ECDC 19.00.005(A)(6)
TO SCHEDULE TNS P ECTIONS
BUILDING ENGINEERING (425) 771-0220 EXT. 1326
1. Go to: www.edmondswa.gov Building Department Inspections
2. Then: Services are now scheduled online. If you FIRE (425) 775-7720
3. Then: Permits/Development have difficulties, please call the
4. Then: Online Permit Info Building Department front desk for PUBLIC WORKS (425) 771-0235
5: If you don't have one already, create a assistance during office hours.
login (upper right hand corner) (425) 771-0220 RECYCLING (425) 275-4801
6: Schedule your inspection
When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection
being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer moming or afternoon.
• E-Erosion Control/Mobilization
• E-Storm Tightline
• E-Storm Connect to Stub
• E-Footing Drain Connection
• E-Water Service Line
• E-Drivcway Form & Slope Ver.
• E-Rctaining Wall Drainage Conn
• EEnginccring Final
• B-Preconstruction meeting
• B-Setbacks
• B-Footings
• B-Foundation Wall
• B-Foundation Drainage
• B-Isolated Footings/Piers
• B-Retaining wall footings
• B-Retaining wall forms
• B-Slab Insulation
• B-Plunib Ground Work
• B-First Floor Framing
• B-Plumb Rough In
• B-Gas Test/Pipe
• B-Mechanical Rough In
• B-FAerior Wall Sheathing
• B-Roof Sheathing
• B-Height Verification
• B-Lath Inspections
• B-Framing
• B-Wall Insulation/Caulk
• B-SheetrockNail
• B-Cross Connection Final
• B-Building Final
OV ED&
CITY OF EDMONDS
121 5TH AVENUE NORTH - EDMONDS, WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
*PERMIT MUST BE POSTED ON JOBSITE*
STATUS: ISSUED ENG20190053
SID.E SEWER PERMIT (I -Single Family)
Permit Number: ENG20190053 Expiration Date: 06/08/2020
Job Address: 15712 72ND AVE W, EDMONDS
APPLICANT CONTRACTOR
ACTS CONSTRUCTION GROUP LLC
250 4th Ave S. PO BOX 27112
Edmonds, WA 98020 SEATTLE, WA 98165
(206) 899-6900
LICENSE #: ACTSCCG824CG FXP: 02/07/2020
JOB DESCRIPTION
N N
�REPAIR N_J PROPOSETO REUSE LATERAL LID NUMBER:
N GRINDER PUMP �N I PROPOSE TO REUSE SIDE SEWER F--N 1 DRAINAGE
Install of new side sewer from home to private sewer manhole on a vacant lot (PLN20140015).
EASEMENT INFORMATION
N9N PROJEC-17 CROSSES OTHER PRIVATE PROPERTY
VERIFICATIONOF RECORDED EASEMENTS COMPLETE
Running through private utility easement AFN:201612095001
,fADEMNITY- The Applicant has signed an application ivhich states he/she holds the City ofEdmonds harmlessfrom injuries,
damages or claims ofany kind or description ivhalsoeverforeseen or unforeseen, that may he made against the City ofEdmonds or
any ofits departments or employees, including but not limited to the defense ofany legal proceedings including defense costs and
atforneyfees by reason ofgranting this permit.
CALL DIALA-DIG (1 -800-424-5555) BEFORE ANY EXCAVATION
CALL FOR INS PECTION (425) 771-0220 EXT. 1326
24 HOUR NOTTCEREQUIRED FOR ALL INSPECTION REQUESTS
APPLICATION APPROVAL
THIS APPLICATION IS NOT A PERVITUNTIL SIGNED BY THE CITY ENGINEER OR HISMER DEPUTY: AND FEES ARE PAID, AND RECEIPTIS ACKNOWLEDGED IN
SPACE PRONIDED,
Printed: Friday, June 07, 2019
CA-e-�t� U)a5�4� (o171201?
RELEA SED BY
DATE
n FILECOPY n INSPECTOR COPY n APPLICANT COPY
STATUS: ISSUED
ENG20190053
• Refer to City of Edmonds Side Sewer Infon-nation handout for approved pipe materials, inspections and other requirements.
• A 6" cleanout with 12" locking cast iron lamphole cover is required at the property line.
• Maintain 10'separation between the sanitary side sewer and the water service line.
• A separate right-of-way construction permit is required for work within the City right-of-way.
• Condition of the existing lateral to be verified by the City's Public Works Dept. to obtain approval for reuse. Contact Edmonds
Sewer Division at 425-771-0235.
• Condition of the existing sanitary side sewerto be verified prior to obtaining approval for reuse. TV inspection required. Video
to be submitted to City for review.
• Easement and/or permission fi-om adjacent property owner is required prior to entry/work within adjacent property.
• Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per City standards that is
caused by or occurs during the permitted project.
• Owner/Contractorto provide Side Sewer asbuilt at final inspection. See City Standards for requirements.
• Sound[Noise originating from temporary construction sites as a result of construction activity are exempt firomthe noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction sites /activities must comply with the
noise lirnits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance ofthis permit. Issuance of this perrnit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance not limit in any way the City's ability to enforce any ordinance
provision.
• E-Sewer MH Channeling
• E-Sewer Tap on private MH
• E-Sanitary Side Sewer Inspection
• E-Engineering Final
PARTIAL INSPECTION
PA RTIAL INSPEMON
FINAL INSPECTION APPROVED
DATE: INITIAL:
DATE: rNITIAL:
DATE: INITIAL:
NOTES:
NOTES:
OV ED
CITY OF EDMONDS
121 5TH AVENUE NORTH - EDMONDS, WA 98020
oc. I PHONE: (425) 771-0220 - FAX: (425) 771-0221
*PERMIT MUST BE POSTED ON JOBSITE*
STATUS: ISSUED ENG20190054
AIGAT OF
Pen -nit Number: ENG20190054 Expiration Date: 06/08/2020
Job Address: 15712 72ND AVE W, EDMONDS Location: 15712 72nd Ave W.
APPLICANT CONTRACTOR
Jared Underbrink ACTS CONSTRUCTION GROUP LLC
250 4th Ave S. CIO MICHAEL ANGELO PUGAL
Edmonds, WA 98020 PO BOX 27112
SEATTLE, WA 98165
(206) 899-6900
LICENSE #: ACTSCCG824CG EXP: 02/07/2020
JOB DESCRIPTION
Use of right of way forconcrete walkway and utility connection.
DISRUPTION INFORMATION
ASSESSED VALUE: $0.00 PROPERTY AREA. 0
SIDEWALK: (OXO) DURATION IN MONTHS: 0 FEE: $0.00 STREET DISRUPTION TRENCH CUT: 0 X 0
PARKING: (OXO ) DURATION IN MONTHS: 0 FEE: $0.00 YEAR OF OVERLAY: 0 FEE: $0 00
ALLEY: (OXO ) DURATION IN MONTHS: 0 FEE: $0.00
INDEMNITY- TheApplicant has signed an application which states helshe holds the City ofFdmonds harmlessfrom injuries,
damages or claims ofany kind or description whatsoever, foreseen or unforeseen, that may be made against the City ofEdmonds or
any ofits departments or employees, including but not limited to the defense ofany legal proceedings including defense costs and
atiorneyfees by reason ofgranting this permil.
THECONTRACTOR IS RESPONSIBLEFOR WORKMANSHIP AND MATIERIALS FOR A PERIOD OF ONEYEAR FOLLOWING THEFINAL
INSPECTION AND ACCEPTANCEOFTHENVORIC
• Traffic Control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must
be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their
possesion.
• Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved
material prior to the end ofthe workday- NO EXCEPTIONS.
• Three sets of construction drawings of proposed work are required with the permit application.
CALL DIALA-DIG (1 -800-424-5555) BEFOREANY EXCAVATION
CALL FOR INSPECTION (425) 771-0220 EXT. 1326
Z4 HU UK AU IIULKLQ L'lKtJ) FO.E.ALL ENSPEC-HON REQUESTS
APPLICATION APPROVAL
THiSAPPLICATION ISNOTA PERMITUNTIL SIGNEDBYT14E CITY ENGINEER OR HISMER DEPUTY: AND FEES ARE PAID, AND RECEIPT IS ACKNOWLEDGED IN
SPACEPROVIDED.
Printed: Friday, June 07, 2019
RELEASED BY
TE
F� FILE COPY F-1 INSPECTOR COPY F—] APPLICANT COPY
STATUS: ISSUED
ENG20190054
• Restore ROW to City standards
• Restore I-andscape to like or better conditions.
• Call for locates of underground utilities prior to any excavation.
• Alert affected residents and/or businesses prior to work start.
• Conforrn to approved working drawings and Traffic Control plan.
• Public utilities maintain 5'separation from City Utilities.
• Verify clear bore crossings
• Utility patch restoration to be in accordance with Edmonds Standard detail E2.3
• Maintain erosion & sedimentation control. Keep street clean.
• Call for required inspections as noted.
• Traffic Control per approved plan and MUTCD. Refer to City of Edmonds traffic control requirements.
• Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per City standards that is
caused by or occurs during the pemnitted project.
• Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pin on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction s ites/activities must comply with the
noise limits of Cliapter 5.3 )0, un less a variance has been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
hanniess the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, aris ing d irectly or indirectly from the is suance of this pen -nit. Is suance of this pen -nit s hall not be deemed to
modify, waive or reduce any requirements of any City ordinance not limit in any way the City's ability to enforce any ordinance
provision.
I INSPECTIONS
• E-Erosion Control/Mobilization
• E-Private walkway
• E-Engineering Final
PARTIALINSPECTION
PARTIAL INSPEC71ON
FINAL INSPECTION APPROVED
DATE:
DATE:
DATE:
INITIAL: NOTES:
INITIAL: NOTES:
INITIAL:
0? EDAf
CITY OF EDMONDS
1215TH AVENUENORTH- EDMONDS, WA 98020
PHONE. (425) 771-0220 - FAX: (425) 771-0221
STATUS: ISSUED ENG20190055
WATER METER RECORD
Permk Number: ENG20190055
Job Address: 15712 72ND AVE W, EDMONDS
PROPERTY OWNER CONTRACTOR
ACTS CONSTRUCTION GROUP LLC
6615 214TH AVE NE PO BOX 27112
REDMOND, WA 98053 SEATTLE, WA 98165
(206) 899-6900
LICENSE 4: ACTSCCG824CG EXP- 02/07/2020
JOB DESCRIPTION
DESCRIPTION OF)hTORK:
New I " meter (vacant lot - PLN20140015)
METER SIM: 1 " I
N NEW SERVICE FROM CITY MA IN TO PROPERTY LINE
N A SPRA LT/CONCRETE CUT
N_ FINALPATCHBYCONTRACTOR
OWNERNAME:
BILLINGADDRESS:
INSTALLATION FEE- $2,970.00
CONNECTION FEF- $5,050.00
STREET CUT DEPOSIT: $0.00
Y SFR N IRRIGATION APARTMENT / CONDO - UNITS:
N
N DUPLEX E FIRECONNECTION N I MIXED US&COMMERCIA L FLOORS
N- TRIPLEX N OTHER:
N- COMBO FIRE/DOMESTIC BA CKFLOW ASSEMBLY REQUIRED
RESIDENTIAL UNITS: 0
PUBLIC WORKS INS TALLATION-UT1LrF'Y BILLING
1ff,T3UiTVi—p7p== UNLOCKED PROJECT NUMBER:
METERNUMBER-
STYLE.
MEIFERREADING-
MANUFACTURER'S #:
METER LOCATION:
SERVICE MATERIAL:
DATE OF WORK:
REMARKS:
U/B A CCOUNT:
READ AFTER ADDRESS:
LOCATE REQUEST #:
DATE CA LLED:
AND
REGSTER #:
PRESSURE: 0 GPM: 0
WORK BY:
***ATTACH DRAWING WHEN NECESSARY***
ROUTE:
WATER SUPPLIER.
ISSUED
TYPEOFREPAIR
F--j Asphalt Roadway/Walkway
= Concrete Sidewalk
= Concrete Curb
AREA REPAtREI)
( Ft X Ft ) = Sq. Yd s
( Ft X Ft ) = Sq. Yds
( Ft X Ft ) = Sq. Yd s
( Ft X Ft ) = Sq. Yds
( Ft X Ft ) = Sq. Yds
( Ft X Ft ) = Sq. Yds
Lineal Ft
Lineal Ft
Lineal Ft
Total Repair Costs:
Less Street Cut Deposit:
Invoice/Refund:
ENG20190055
IS 0-6". 1
$0.00
01'
------------
76� -3-
14 7—OW-275 001 —(1)
Tol��161 or 111L,�
Dt
L
TOW-279.5
T -27750
TOF-275.5
T -273,5
OF-
C o
TOF=270 75
Q)
91 SI
TOW476.00
TOW-270.00
TOF=25950
"f
t
BOO
�T.'l z �2 T=OW=2B 00 TOW-26T�7�fl
1
7 1
BSMT=258.0
6
IST FLR=2
TOF- ;55 Q50
TOF=2(t171j'
Eib
TOP-260 00
- --------- -----
J
----- -------
----- ------ TOW=256
0
TOF=255 75
2
7
------ TOF=25475
TOF=256,50 TOF-254.75
TOW-261.50
PROJE�GfEd'
0-22
RETAINING WALL PLAN 2 81
SCALE 1/8" - 1`0" 0' 4' 16,
ALL WORK SUBJECT APPROVED
TO FIELD
INSPECTION FOR
CODE COMPLIANCE PLANS MUST BE
,_O" L 4'-l" L 4`2" L T-9" L 11,1'. L 4'-4" 1 1
ON JOB SITE 2/62 2/S2 l/S2 2/62 3/92
CITY OF EDMONDS
BUILDING DIVISION --------- I
275.00 -------- ---------- -------------- I --------------- I ------ 275.00 _I M
APPROVED PLAN ----- 272.00
---4--� � r ----- ---- 1� ------------------------------------- -
City Of Edmonds
Building Department
Work REVISION 3 FOR RETAINING WALL
Address 1,5712 72 AVE WES
Owner SHARMA_AMIT
Approved Date - 6/22/2020
Building Official 'W-
Permit Number BLD2018-1 101 REVISION #3
REVISION
Jul 08 2020
CITY OF EDMONDS
DEVELOPMENT S FIVICES
DEPARTMENT
TOFz265,50
1 44- 51
266.00
25800
(S:)WALL ELEVATION
'E51
�/ SCALE 118" = 1'-0"
PLAN KEYNOTES
I CAST IN PLACE CONCRETE RETAINING WALL. SEE WALL SECTIONS
& ELEVATIONS FOR WALL DIMENSION & REINF
2. FTG STEP. SEE 762
3, ADJACENT RETAINING WALL PER THE ORIGINAL DESIGN BY: MAINLAND
ENGINEERING CONSULTANTS CORPORATION
LEGEND
C STEP FTG. SEE 7152
TOW TOP OF WALL
TOF TOP OF FOOTING
DIMENSIONS & ELEVATIONS
0 1 MENS[ONS AND ELEVATIONS ON THIS PLAN ARE PROVIDED
FOR ESTIMATING PURPOSES ONLY THE CONTRACTOR $HALL
BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND
ELEVATIONS WITH THE CURRENT PERMITTED SET OF CIVIL
DRAWINGS AND THE EXISTING GRADES IN THE FIELD AT THE
TIME OF CONSTRUCTION ANY DISCREPANCIES SHALL BE
REPORTED TO BOTH THE CIVIL AND STRUCTURAL ENGINEERS
IN WRITING PRIOR TO CONSTRUCTION OF THE WALL
271,10, 279
27700
27200 272,00
---------------
--------------- 266.00 266.00__
(T)WALL ELEVATION rc"\WALL ELEVATION (�,)WALL ELEVATION
'\�SCALE EIIB'� '\�SCALE �118'- V-O"�� '\�SCALE 7118"-
27700
275,00
�17 4. 1 �O
272.00 272.00
------- ----- ---------- -- -------- - ------ I --------------------- ---
27000
268.00
L 267,00
62.70
262.00
- -----------
25700
- ----------- --- ----------------- ----- - ---------- -- L
(�E7)WALL ELEVATION
\,�SCALE �1/8= 1'-O�"��
267.00
----------------
262.00
2 00
57
/';`\WALL ELEVATION
\,� �SCALE I18"V-O" �
xwl),0/14=3
274" 26700
----- ----------------------------------------
2152.00
25TOO
-------- -------
(—G�\WALL ELEVATION
\,�SCALE �1/8'- 1
,L 1*
7 c?
z
0
6
LU
_j
-j
z 4C
LU �r.
0
aj a
LU Z
CC 2
LLI 60
z
0
LL,
LLI
CO) LL
0
L
D
LU
si
+811+
all �
=RUN=
RET. WALL SECTION RET. WALL SECTION T W LL SECTION RET, WALL SECTION
K�SEZE �G1701�1_���
SCALE 1/211=11-011 KSrSCALE SCALE 1/21:=J.-011
GENERAL CONSTRUCTION NOTES
CODE:
DE SIGN AND CONSTRUCTION SHALL CONFORM TO THE PROVISIONS Or
THE 201 5 IBC AS ADOPTED BY THE CITY Or EDMONDS, WASHINGTON.
DISCREPANCIES:
THE CONTRACTOR SHALL NOTIFY ENGINEER UPON FINDING ANY
DISCREPANCY OR OMISSION IN THE DRAWINGS OR SPECIFICATIONS.
SHORING & EXCAVATION:
THE CONTRACTOR SHALL Off SOLEY RESPONS15LC FOR ALL EXCAVATION
PROCEDURES AND PROTECTION OF ADJACENT PROPERTY,
BACKFILL SOIL
WALL BACKFILL SHALL Be WELL GRADED FREE DRAINING MATERIAL.
BACKPILL SHALL BE PLACED IN ACCORDANCE WITH THE GCOTECHNICAL
ReCOMMFNOATIONS . ALL COMPACTION OCCURING WITHIN S' OF THE
WALL SHALL Be COMPLETED USING HAND OPERATED MACHINERY.
DESIGN CRITERIA
FOUNDATION DESIGN:
RETAINING WALL DESIGN 15 EASED ON THE FOLLOWING VALUES AS
PROVIOCO IN T14C GEOTECHNICAL REPORT BY GEOTFCH CONSULTANTS
INC. DATED 01-25-18 & E-MAIL CORRESPONDENCE OF 09-27-T&
ALLOWABLE BEARING PRESSURE. 3,000 PSF
LATERAL EARTH PRESSURES: DRAINED BACKFILL
ACTIVE CONDITION: 35PCF EFW I LEVEL 5ACKFILL I
S'PREVI'StON
PASSIVE CONDITION: 30OPCF EFW ULTIMATE
SEISMIC ADDITION: E w 8H PsAwIlioN 2020
SATURATED SOIL DENSITY 125 PCF ./CLIVEDIFBIMMUDS
135
DEPARTMENT
COEFF OF FRICTION: 050 ULTIMATE
SPECIAL INSPECTION PLAN
GENERAL *
SPECIAL INSPECTION BY A QUALIFIED INSPECTOR 15 REQUIRED IN
ACCORDANCE WITH THE 2015 IBC.
QUALIFICATION.
THE SPECIAL INSPECTOR $HALL BE A QUALIFIED PERSON WHO SHALL
DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE BUILDING
OFFICIAL.
REQUIRED VERIFICATION & INSPECTION:
THE SPECIAL INSPECTOR SHALL PERFORM THE VERIFICATIONS &
INSPECTION$ NOTED IN THE SCHEOU�E BELOW
INSPECTION & TESTING SCHEDULE
TYPES OF WORK
FREQ
I
12015 15C
SECTION
CAST IN PLACE CONIC
REINFORCING STEEL, PLACEMENT
P
170"
PLACEMENT OF CONCRETE
C
17053
VERIFYING USE OF REQUIRED DESIGN MIX
p
1705.5
TESTING OF THE CONCRETE FOR SPECIFIED
STRENGTH, AIR CONTENT AND SLUMP
C
I T705.5
SOILS
VERIFICATION OF SOIL -BEARING CAPACITY
INSTALLATION OF DRAINAGE SYSTEM:
I C
1,705.6
PLACEMENT & COMPACTION OF WALL
BACKFILL.
P
I
1705.6
I
FREQUENCY LEGEND
C = CONTINUOUS P w PERIODIC
SUBMITTAL OF REPORT&
ALL SPECIAL INSPECTION REPORTS AND TESTING REPORTS SHALL BE
SUBMITTED TO THE OWNER, SITE STRUCTURES AND THE BUILDING
OFFICIAL BY THE AGENCY PERFORMING THE INSPECTION ON TESTING.
CONCRETE
CONCRETE REQUIREMENTS:
LOCATION STRENGTH MAX WIC RATIO
WALL5 & rTGS 350OPS1 0 28 DAYS 0.50
AIR CONTENT;
CONC.IXPOSED TO WEATHER SHALL CONTAIN 59 -1-19 ENTRAINED AIR
MIX DESIGN:
SHALL BE BASED ON FIELD EXPERIENCE OR TRIAL MIXTURES IN
CONFORMANCE WITH THE SPECIFICATIONS.
MATERIAL REQUIREMENTS;
CEMCNT� ASTM C150. ADMIXTURES: ACI 301
AGGRtGATES,. ASTM CB5. WATIRi ASTM C94
EXPOSURE CATEGORIES:
FREEZING THAWING Fl
SULFATE so
IN CONTACT W WATER Wl
CORROSION PROTECTION Cl
PLACING REQUIREMENT&
PLACING:
PLACE CONCRETE AS NEARLY AS PRACTICABLE TO ITS FINAL POSITION
TO AVOID SEGREGATION.
DEBRIS:
REMOVE ALL DEBRIS FROM FORMS PRIOR TO PLACING CONCRETE,
CONSOLIDATION
CONSOLIDATE CONCRETE BY SUITABLE MEANS. THOROUGHLY WORK
CONCRETE AROUND EMBEDDED ITEMS AND INTO CORNERS OF FORMS
REINFORCING BAR
+ 6'-3"
RET. WALL SECTION
SCALP 1/2"=I'-O..
MATERIAL REQUIREMENT:
REINFORCING OARS:
USE DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60, EXCEPT
AS NOTED ON THE DRAWINGS,
FABRICATION AND PLACING REQUIREMENTS:
BLNDING:
BARS SHALL BE BENT COLD. BARS PARTIALLY EMBEDDED IN CONCRETE
SHALL NOT BE FIELD BENT UNLESS NOTED OR SHOWN OTHERWISE OR
AUTHORIZED By THE ENGINEER.
CONCRETE COVER:
MINIMUM CONCRETE COVER FOR RI!INff SHALL BE AS FOLLOWS, UNLESS
NOTED OTHERW:Sl�
CONCRETE CAST AGAINST EARTH-3"
CONCRETE CAST AGAINST FORMS AND
EXPOSED TO EARTH- 1-1/2"
WET SETTING&
REINFORCEMENT ANCHOR BOLTS, OR ANY EMBEDDED ITEM WITHIN THE
CONCRETE, MAY NOT BE SET INTO THE CONCRETE AFTER IT HAS BEEN
POURED WITHIN THE FORMS
LAP SPLICES:
LAP ALL BARS 24�' MIN UNLESS SHOWN OTHERWISE ON THESE DWGS.
WALL SECTION
GENERAL KEYNOTES
1. APPLY PREFABRICATED DRAINAGE PANEL TO ALL WALLS. EXTEND
DRAINAGE PANEL TO WITHIN 12" OF FINISHED GRADE. SEE
GEOTECHNICAL ENGINEER FOR MATERIAL SPECIFICATIONS.
2. 4's PERFORATED PVC FOOTING DRAtN AT ALL WALL SECTIONS.
WRAP IN 161-xl6-1 MINIMUM DRAIN ROCK BEDDING & FILTER FABRIC.
ROUTE DRAIN TO DISCHARGE POINT AS SHOWN ON CIVIL DINGS.
3� LEAVE SURFACE BETWEEN WALL & FOOTING ROUGH.
4. FINISHED GRADE AT THE BACKFILL FACE OF THE WALL. HEIGHT
OF BACKFILL MAY EXTEND TO THE TOP OF THE WALL.
5. CONCRETE PAVING SECTION AT THE DOWNHILL FACE OF THE
WALL. PROVIDE 6" MIN COVER OVER THE TOP OF THE FTG.
WALL SECTION
REINFORCING KEYNOTES
100. 8- THICK CONCRETE RETAINING WALL, REINP W 15612"alc HORZ &
VERT. PLACE VERT REINF NEAR THE BACKFILL FACE OF THE
WALL. PROVIDE (2145 CONTINUOUS HORZ BARS @ THE TOP OF
THE WALL.
101 Sm THICK CONCRETE RETAINING WALL. REINF w/ #501210o/c HORZ &
1 5016'-o/c VERT. PLACE VERT REINF NEAR THE BACKFILL FACE
OF THE WALL. PROVIDE (2145 CONTINUOUS HORZ BARS @ THE
TOP OF THE WALL ENE, VERT BARS INTO FTG �/ STD HOOK 0
3FT TALL WALL
02. #5@121to/c TRANSVERSE,
03. 05016"o/c TRANSVERSE.
104 Is LONGITUDINAL TOP & BOT AS SHOWN. LAP 24" MIN III ALL
SPLICE LOCATIONS.
105. #5 WALL TO FOOTING DOWELS @ Wok PROVIDE $TO HOOK @
END OF BAR CAST INTO FOOTING. DOWELS SHALL BE EMBEDDEO
A MINIMUM OF 11' INTO 14' THK FTG. SEE 6/S2 FOR PLACEMENT
REQUIREMENTS.
106. #6 WALL TO FOOTING DOWELS @ 1611 o/c. PROVIDE STO HOOK @
END OF BAR CAST INTO FOOTING. DOWELS SHALL BE EMBEDDED
A MINIMUM OF III-- -/- 1/2-- INTO THE 12' FOOTING. SEE 61S2 FOR
PLACEMENT REQUIREMENTS.
107. 1 5 WALL TO FOOTING DOWELS @ 1611 c/c. PROVIDE STD HOOK @
END OF BAR CAST INTO FOOTING DOWELS SHALL BE EMBEDDED
A MINIMUM OF 1111 ./- 1/2' INTO THE 14' FOOTING. SEE 6/52 FOR
PLACEMENT REQUIREMENTS.
108 #4@12'./c
DOWEL & VERT REINP TO BE PLACED IN
LINE DOWN THE LENGTH OF THE WALL
00 /( /,**"
DOWEL ./� VERT I/ FTG TO WAI I J L VERT WILL IIINI
5AR 5PLTCE DOWEL
TYP FTG DOWEL PLACEMENT DETAIL
SCALE Vz`3`
6'-0* MIN V-4"
-W M, 7
2
MIN
, 11 i" PI I OAN
FTG CONT REINF
SPLICE BARS TO MATCH
FTG REINF
TYPICAL STEPPED FTG DETAIL
SCALE 3/8`4-011
' 52
jw
1 aj�
Lu
0
z
w
In
75
Lu
m
w
z
0
co
0
z
2
LU w
cc 0
z
0
Lu a
93
Lu
LIL.
0
9
R
ru
S20F 2
S-19-083
6 -W
V. 10 ,
BUILDING PERMIT
APPLICATION
Development Services
Building Division
121 5th Ave N / Edmonds, WA 98020
425.771.0220
For handouts, submittal requirements, permit status and inspection
scheduling information go to: http://www,ecImondswajzov/
JOB SITE INFORMATION/LOCATION: (Where the work Is taking place)
JobSiteAddress: 1571272ndAveW
Parcel: 00513100002411
Lot /Unit/Suite #: 1 Subdivision: Meadowview Estates
PROPERTY OWNER:
Name: Amit Sharma
MailingAddress: 1737ANW60thSt
City/State/Zip: Seattle, WA 98107
Phone #: 425.280.8457
Email: Amit.Sharma@Docusign.com
OWNER INSTALLATION: *If yes, read and sign*
Will work be performed by the property owner? 0 Yes IN No
I own, reside in, or will reside in the completed structure.
This installation is being made on property that I own which is
not intended for sale, lease, rent, or exchange according to
RCW 18.27.090.
Owner Signature:
APPLICANT/ CONTACT INFORMATION:
Name of Applicant: Jared Underbrink
Mailing Address: 250 4th Ave S
City/State/Zip: Edmonds, WA 98020
Phone #: 425.778.8500
E-mail: JareclUCE)cciengineering.com
GENERAL CONTRACTOR: (if different from applicant)
General Contractor:
Mailing Address:
City/State/Zip:
Phone #:
E-mail:
WA STATE CONTRACTOR L & I # (CCB) & EXPIRATION DATE:
CITY OF EDMONDS BUSINESS LICENSE #:
Perrnit
TYPE OF PERMIT (Provide Details on Page 2)
El Accessory Structure/ 0 Addition
Detached Garage
El Demolition
0 Mechanical
IR New Single Family / Duplex
0 Plumbing
• Fire Sprinkler
0 Remodel
• New Commercial/ Mixed Use
0 Re -Roof
• Signs
0 Tank
OTenant Improvement
0 Other
Remodel Permit fees are based on:
The value of the work performed. Indicate the value (rounded to
the nearest dollar) of all equipment, materials, labor, overhead,
and the profit for the work indicated on this application.
Valuation:
PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION
Basement sq ft: Finishec% Unfinished 0
Ist Floor, sq ft:
2nd Floor, sqft:
1,-770
Garage/Carport:, sq ft:
Deck/Covered Porch/Patio:
Other sq ft:
PROJECT DESCRIPTION
New SER on previously undeveloped lot, Work will
include clearing, grading, utility installation, & retaining
walls.
I certify that the information I have provided on this form/application Is true,
correct and complete, and that I am the property owner or duly authorized
agent of the property owner to submit a permit application to the City of
Edmonds.
Print Name:
Signature: -C� �Date 2Z21A7_'_
. 6.
GENERAL
Cccupancy Group(s):
COMMERCIAL DATA
Occupant Load(s):
Type(s) of Construction:
Fire Sprinklers: Yes%& No El
WA STATE ENERGY CODE: If your project affects the building envelope,
mechanical systems, and/or lighting, you must complete the
appropriate WSEC forms.
DEFERRED SUBMI17ALS: All commercial building permits that will require
associated plumbing, mechanical, fire sprinkler, and/or fire alarm
permits are applied for separately.
LT, / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet
MECHANICAL EQUIPMENT COUNTS (New and Relocated)
BTUs Gas / Elec / Other QtY
A/C Unit /Compressor
Air Handier /VAV
Boiler
Dryer Duct
Exhaust Fans
C7
Fireplace
00 IL7�1
Furnace
Heat Pump Unit
Hydronic Heating
Roof Top Unit (Provide eleva-
tions 11' a Cornmercla I Bldg)
Other:
PLUMBING FIXTURE
QtY
COUNTS (New, Relocated or re -piped)
City
ClothesWasher
Tub/ Showers
Dishwasher
Backflow Device (RPBA, DCDA, AVB)
Drinking Fountain
Pressure Reduction/ Regulator Valve
Floor Drain/Sink
Refrigerator Water Supply
Hose Bibs
Water Heater - Tankless? Y or N
Hydronic Heat
Water Service Line
Sinks
other:
Toilets
7
other:
GAS/FUEL CONNECTION COUNTS (New, Relocated or re -piped)
BTUs Qty BTUs City
A/C Unit
&O.C�L)
4- "'4�
9
Outdoor BBQ / Fire pit
i001000
L
Boiler
1crL
Stove/Range/Oven
Dryer
Water Heater
Fireplace/ Insert
Other:
Furnace Other:
MEDICAL GAS, AIR VACUUM COUNTS
(New, Relocated or re -piped)
Qty
Qty
Carbon Dioxide
Nitrous Oxide
Helium
Oxygen
Medical Air
Other:
Medical - Surgical Vacuum Other:
DEMOLITION
Type of structure to be demolished:
Square footage of structure to be demolished:
AHERA Survey done? Y/N
PSCAA Case #:
Critical Areas Determination:
StudyRequiredE] Conditional Waiver 0 WaiverEl
Fill In Place El Fill Material:
Removal
Size of Tank (Gallons)
Critical Areas Determination:
Study Required 0 Conditional Waiver EI Waiver 0
GRADE/FILL/EXCAVATE
Grading: Cut 700 - cubic yards
Fill 750 cubic yards
Cut/ Fill in Critical Area: YesEl No
GENERAL PROVISIONS
APPLICATIONS: Applications are valid for a maximum of 1 year.
ESLHA Applications, 2 years.
LICENSING: All contractors and subcontractors are required to be licensed
with Washington State Department of Labor & Industries and have a
current City of Edmonds Business License.
City of Edmonds
Critical Area Notice of Decision
Applicant:
lAt-V-D UkD-ek;I'#JjL
Property Owner:
-494T 5#49^4
Critical Area File #:
C447
'0/gI00& Z
Permit Number:
Site Location:
/5?/Z 72,,-o,4vc- V) I
Parcel Number:
00'5J_;J0.A00Z411
Project Description:
AIEW 51IJ6cc- Almll-
F� Conditional Waiver. No critical area report is required for the project described above.
I . There will be no alteration of a Critical Area or its required buffer.
2. The proposal is an allowed activity pursuant to ECDC 23.40.220, 23.50.020, and/or
23.80.040.
3. The proposal is exempt pursuant to ECDC 23.40.230.
P!r-Erosion Hazard. Project is within erosion hazard area. Applicant must prepare an erosion and
sediment control plan in compliance with ECDC 18.30.
M/C00'ritical Area Report Required. The proposed project is within a critical area and/or a critical area
buffer and a critical area report is required. A critical area report has been submitted and evaluated
for compliance with the following criteria pursuant to ECDC 23.40.160:
1. V The proposal minimizes the impact on critical areas in accordance with ECDC 23.40.120,
Mitigation sequencing;
2. %/ - The proposal does not pose an unreasonable threat to the public health, safety, or welfare
on or off the development proposal site;
3. The proposal is consistent with the general purposes of this title and the public interest;
4. Any alterations permitted to the critical area are mitigated in accordance with ECDC
23.40.110, Mitigation requirements.
5. The proposal protects the critical area functions and values consistent with the best
available science and results in no net loss of critical functions and values; and
6. V/ The proposal is consistent with other applicable regulations and standards.
Unfavorable Critical Area Decision. The proposed project is not exempt or does not adequately
mitigate its impacts on critical areas and/or does not comply with the criteria in ECDC 23.40.160 and
the provisions of the City of Edmonds critical area regulations. See attached findings of
noncompliance.
2f Favorable Critical Area Decision. The proposed project as described above and as shown on the
attached site plan meets or is exempt from the criteria in ECDC 23.40.160, Review Criteria, and
complies with the applicable provisions of the City of Edmonds critical area regulations. Any
subsequent changes to the proposal shall void this decision pending re -review of the proposal.
F] Conditions. Critical Area specific condition(s) have been applied to the permit number referenced
above. See referenced permit number for specific condition(s).
Notice on Title. Critical area notice on title recorded under AFN Z 0/10- 2-If—ca
"
Reviewer
/ -_;o- 6
Date
Appeals: Any decision to approve, condition, or deny a development proposal or other activity based on the
requirements of critical area regulations may be appealed according to, and as part of, the appeal procedure, if any,
for the permit or approval involved.
Revised 1112912016
APPENDIX A
Page 1 of 2
25 2018 0
Transportati n-9W Analysis
Worksheet 04
1.7 C. I sl.)�
PERMITTING & DEVELOPMENT
ENGINEERING
D I V I S 10 N
121 5th Avenue N
P: 425.771.0220
www.edmondswa.gov
Name of Proposed Project: �,D�av-ff)ck 'Rec"lae-VAce
Owner/Applicant
� V) % -� !SV--1a_rff�Ck
Name
Street/Ma'llng Address
5ze-me W)
city State Zip
Telephone:4ze;,2z—,.sis3
V_�_
Applicant Contact Person:
Name
'Z Sb 4 Tri Aw Q_ S
Street/Mailing Address
City State zip
Telephone: 4?,L,,!5.M8.aGP0
Traffic Engineer who prepared the Traffic Impact Analysis (if applicable): (�J/�_)
Firm Name
Telephone:
1. PROJECT DESCRIPTION
Contact Name
E-mail:
a. Location - Street address: i Z_ :77-op A,.e- t-J
(Attach a vicinity map and site plan.)
b. Specify existing land use: U--6e-Je-tC22<--'8J �0 k_
c. Specify proposed type and size of development: :z;, ryke '(IefjZ�h �Q_
(# of residential units andlor squarefootage of building)
d. Date construction will begin and be completed:
e. Define proposed access locations: QV� OY- Ret-D
'10 NIT
APPENDIX A
Page 2 of 2
f. Define proposed sight distance at site egress locations:
2. MITIGATION RECOMMENDATIONS
State recommended measures and fees required to mitigate project specific traffic impacts.
Traffic impact fee shall be calculated from the attached Impact Fee Rate Tables and as identified
in ECDC 18.82.120, except as otherwise provided for independent fee calculations in ECDC
18.82.130.
L CHANGE IN USE
Fee for prior use shall be based on fee established at the time the pnior use was permitted. If
the previous use was permitted prior to the adoption of Ordinance 3516 (effective date:
09/12/04), the 2004 ECDC 18.82.120 impact fee shall be used.
ITE Land Use Category
New Use
Prior Use
Units in
Per Unit square feet,
Fee Rate # of dwelling,
vfb. etc.
$ X
$ X
New Use Fee: $ - Prior Use Fee: $ 1 = 1 $ 1 1
NEW DEVELOPMENT
Units in
ITE Land Use Category Per Unit square feet, Fee
Fee Rate # of dwelling,
vfp, etc.
New Use &7'7-Lict� X $ U,7-44.14
OTHER
MITIGATION FEE RECOMMENDATION:
$
INDEPENDENT FEE CALCULATION: $240.00 (+ consultant fee)
$
TOTAL TRANSPORTATION IMPACT FEE
$
City of Edmonds, Engine- ering* Division Approval
' No impact fees will be due, nor will a credit be given, for an impact fee calculation resulting in a net negative.
w
d
EVA,104"
AAV�—
. 1 8<30
ROW PERMIT NO.: ENG 2-61C?
ISSUE DATE:
RIGHT-OF-WAY CONSTRUCTION
PERMIT APPLICATION
PROJECTNAME: S�rWW?a A4,W1,Vt CONTACT:
CONTRACTOR: &/b Coo-54ya
Mailing Address:
State License #: S-d 14
City Business License #:
oA.) 6�Vftone #: go.( _ 5V 5 - (02W
49,
rax #
Email #: b a nzc AC45 Qyw
Ll Liability Insurance F1 Bonded
ADDRESS OR INTERSECTION OF CONSTRUCTION: 2 3 2, "-A NV t 0
ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT:
n Commercial 0 Subdivision F1 City Project El Traffic Control (Only)
F� Multi -Family F-1 Single Family
n EUC (PUD, VERIZON, PSE,
COMCAST, OVWSD):
Is this pennit part of a blanket permit?
F] Other
El Yes EJ No
I ANY ASSOCIATED PERMITS? I I BLD# ENG# I
DESCRIPTION OF PROPOSED WORK (Be Specific): L/211--
4'.&A zr--4 "ZJ 14 (4) &:-� g2AJ V�# 6ki i-OAA (! &Z'J
I WAS STREET OVERLAYED WITHIN THE LAST FIVE (5) YEARS? W—SE] NO 0 Year.----]
PAVEMENT CUT: M Yes EJ No
CONCRETE CUT: [I Yes n No
If yes, indicate size of cut: x
If yes, indicate size of cut: x
RIGHT-OF-WAY
AREA
CLOSURE
TOTAL
DURATION
(NUMBER OF MONTHS)
Sidewalk 48 Hrs + LF
X
LF
SF
dSF
Alley 72 Hrs + LF
X
LF
SF
Parking 72 Hrs + LF
I X
LF
APPLICANT TO READ AND SIGN
*Traffic control and public sa&ty shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification
verifying completion of the required training in their possession.
*Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS.
Indemnity: The Applicant has signed an application which states helshe hold the City of
Edmonds harmless from injuries, damages or claims of any kind or description
whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or
any of its departments or employees, including defense costs and attorney fees by reason
of granting this permit.
I have read the above sl
follow all requirements
SIGNATURE
and understand the permit requirements and acknowledge that I must
for the permit to be valid. DATE 6� __S_ _/ 7
or Agent
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
of ED
.1690
CONTRACTOR INFORMATION:
SIDE SEWER
PERMIT APPLICATION
Company Name: tr4 6kouigsite Contact: g6r)jle
�r 15 (on 5 4rue-A'
Company Address:
7:6 &v-x 0,
city: Zip: g9l
State License # k45 C—C—q
Expiration Date: Abov �z di
. 7
PROPERTY INFORMATION:
Address:
F062-,bjc(ooS-�
Phone #: Po (p — 57-0 3 - (a,2�0 D
Email #: Oern i e OW�--5 C 6. Loy,,
City Business License #
Owner's Name:
Phone #:
FULL LINE REPLACEMENT E] SPOT REPAIR [I PIPE BURST 0 RELINE (PERMALtNE ONLY)
DESCRIPTION OF PROPOSED WORK (Be Specific):
04 A !ZAlelAl;l- l0i 4PLA).apt qay
ISSUANCE OF THIS PERMIT DOES NOT CONSTITUTE PERMISSION TO WORK ON ANY PROPERTY OTHER
THAN THAT OWNED BY THE SUBJECT PROPERTY OWNER.
CERTIFICATIONS NECESSARY FOR INSTALLATION METHODS ARE THE RESPONSIBILITY OF THE
CONTRACTOR PERFORMING SAID WORK.
I REPRESENT AND WAR]
ADJACENT PROPERTY, I
PROPERTY.
SIGNATURE
TO THE CITY OF EDMONDS, IF REPAIR OF EXISTING SEWER EXTENDS TO AN
OWNERS EXPRESS PERMISSION TO PERFORM WORK ON THAT ADJACENT
DATE b - 5— 1
or Agent
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
GENERAL NOTES
LIFE SAYETY NOTES (continued)
FRAMING NOTES (continued
Nothing in this pen -nit approval process shall be interpreted as
allowing or permitting the maintenance of any currently existing
illegal, nonconforming, or unpermitted building, structure, or site
condition which is outside the scope of the permit application,
regardless of whether such building, structure, or condition is
shown on the site plan or drawing. Such building, structure, or
condition may be the subject of a separate enforcement action.
Sound/noise originating from temporary construction sites as a
result of construction activity are exempt from the noise limits
only during the hours of 7:00arn to 6:00pm on weekdays and
10:00arn and 6:00pm on Saturdays, excluding Sundays and
Federal Holidays. At all other times the noise originating from
construction sites/activities must comply with the noise limits,
lunless a variance has been granted. ECC Chapter 5.30
All changes in plans and field modifications shall be approved by
the local jurisdiction. The design professional shall prepare
drawings as required for approval. IBC 107.4
Temporary address shall be clearly visible from street during all
phases of construction. Failure to properly post house/building
numbers may result in no inspection by the City Inspector.
Curb signage is not acceptable.
Address numbers (4" min. lit. & 1/2" min. stroke width) shall be
posted to be plainly visible from the street or road fronting the
property. IRC R319
LIFE SAFETY NOTES
Smoke alarms shall be installed in each sleeping room, outside of
each separate sleeping area in the immediate vicinity of the
bedrooms, and on each level (including basements and habitable
attics) in new construction and in existing dwellings when
alterations, repairs or additions requiring a permit occur. Smoke
alarms shall be hard -wired with battery backup, and when more
than one smoke alarm is required within an individual dwelling
unit, they shall be interconnected. Discuss exceptions to the
power source requirements with the Building Inspector.
IRC R314 IBC 907.2.11.2
Carbon monoxide alarms shall be installed outside of each
separate sleeping area in the immediate vicinity of the bedrooms
and on each level in new construction and in existing dwellings
when alterations, repairs or additions requiring a pen -nit occur, or
when one or more sleeping rooms are added or created. IRC R315
Handrails and guards must be capable of resisting a concentrated
load of 200 pounds per square foot applied in any direction at any
point along the top. Guard in -fill components must be capable of
resisting 50 pounds per square foot.
IRC Table R301.5 IBC 1607.8
Handrails shall be continuous through stair flights of four or more
risers, without interruption by newel posts (unless at a turn) or
other obstructions, and return to a wall, newel post, or safety
terminal. The grip -size shall be Type I or H or of equivalent
,graspablity. IRC 311.7.8
Provide one operable escape window in the basement, habitable
attic and in each sleeping room meeting all of the following
requirements:
-An operable area of not less than 5.7 sq. ft. (5 sq. ft. for grade
floor opening)
-A minimum clear opening height of 24 inches
-A minimum clear opening width of 20 inches
-Not more than 44 inches between the finished floor and the
bottom of the clear opening.
Escape windows located under decks or porches must have a path
36 inches in height to a yard or court. R310 IBC 1029
The greatest riser height within any flight of stairs or the greatest
tread depth within any flight of stairs shall not exceed the smallest
by more than 3/8 inch.
IRC R311.7.5.1 IRC R311.7.5.2 IBC 1009.7.4
FOOTINGS/FOUNDATIONS
Footing drains are required around concrete/masonry foundations
that retain earth and enclose habitable or usable spaces located
below grade, or for crawl spaces when a minimum 6 inch slope
within the first 10 feet of the foundation wall is not achieved. A
separate footing drain inspection by the Building Inspector is
required. IRC R401.3 IRC R405.1
Slab -on -grade floors shall be a minimum 3.5-inch thick concrete
over a 6 mil vapor barrier and 4-inch base of sand/gravel/etc.
There shall be a thermal -break for slabs inside a foundation wall,
and if the slab is less than 24" below the exterior grade, 24" wide
R-10 perimeter insulation must be provided. Slabs used as part of
a hydronic heating system shall have R- 10 insulation provided
throughout the entire slab area.
.1RC R506 WSEC R402.2.9 WSEC Table R402.1.1
Vertical rebar must be hooked and tied in place at time of footing
inspection. Maintain minimum 3" clearance to earth, 1-1/2" to
form -work for reinforcement. R403.1.3 R404.1.2.3.7.4
Anchor bolts shall be at least 1/2 -inch in diameter and extend 7
inches into concrete. There shall be a minimum of two bolts per
plate, with one bolt within 12 inches but not closer than seven bolt
diameters from the end of the plate. The bolt spacing shall not
exceed 6 feet o.c. and shall have a nut and 3"0"0.229" washers
unless engineered. IRC R403.1.6
FRAMING NOTES
Hardware and fasteners in contact with preservative -treated wood
shall be of hot -dipped zinc galvanized steel, stainless steel, silicon
bronze or copper. IRC R317.3.1 IBC 2304.9.5.1
Joists less than 18" and beams less than 12" to grade and all wood
exposed to weather shall be preservative -treated or naturally
resistant to decay. IRC R317 IBC 2304.11
Joists shall have not less than 1.5 inches bearing on wood or metal
and 3 inches on concrete. Joists shall be prevented from rotating
at the ends and at intermediate support by approved hangers, 2
inch nominal blocking, or attachment to a rim board.
IRC 502.6/502.7 IBC 2308.8
Foundation cripple walls shall be framed of studs not less in size
than the studs above. Walls over 4 feet in height shall be framed
of studs having the size required for an additional story. Cripple
walls studs less than 14 inches in height shall be sheathed on at
least one side with a wood structural panel that is fastened to both
the top and bottom plates in accordance with Table R602.3(l), or
cripple walls shall be constructed of solid blocking. Cripple walls
Ishall be supported on continuous foundations. IRC R602.9
Prior to the framing inspection, the building must be dried in with
a minimum of roofing, windows, and siding paper installed.
Truss layouts showing girder truss/hip-master locations are not
permitted to change and must be followed correctly. If the truss
manufacturer requests to change, in part or in whole, the layout
shown, they must contact the architect/designer to ensure that the
structural design of the building is maintained. If the layout
shown is changed, in part or in whole, the Building Division
requires new engineering calculations and must approve the
changes prior to the installation of the roof sheathing.
Exterior and bearing wall studs may be notched <25% and bored
<40% of the stud width. Non -bearing wall studs may be notched
<40% and bored <60% of the stud width. Any bore located <5/8"
from the stud face is considered a notch. Rafters and joists may
be notched in the outer thirds of the span with a maximum notch
depth 1/6th and a notch width 1/3rd the depth of the member.
Rafters and joists may be bored up to 1/3rd the depth of the
member no closer than 2" to each edge or to another bore. Top
plates notched or bored >50% of the width must have a l6ga.
strap, 6 inches past and fastened with 8- 1 Od nails at each side of
,the opening. IRC R502.8 IRC R602.6 IBC 2308
Attic access openings are required for buildings with combustible
ceiling or roof construction over an area >30 sq. ft. and with a 30"
vertical space between ceiling and roof framing members. The
rough -framed opening shall be 22"x3O" and located in a hallway
or other readily accessible location. The access cover shall be
weather-stripped and insulated to a level equal to the surrounding
isurfaces. IRC R807.1 WSEC 402.2.4
Attic ventilation openings shall not be less than 1/150 of the area
of the space ventilated. It may be reduced to 1/300 if at least 50
percent and not more than 80 percent of the required openings are
at least 3 feet above the eave vents with the balance provided by
the eave vents. The net free cross -ventilation area may also be
reduced to 1/300 when a Class I or H vapor barrier is installed on
the warm-m-winter side of the ceiling. IRC R806.2
ADDITIONAL REQUIREMENTS
A survey may be required prior to the foundation wall inspection if
the Building Inspector is unable to verify setbacks. Lot line stakes
should be in place at the time of the foundation inspection and
established property pins should be made visible.
C)
<
E
C)
E
0
U
�D
U
U, � U
CN
MECHANICAL NOTES
FLUMBIIN(i INUThN
PlKh-KATLI) WfNNTKUCT1UN
IProvide outdoor air inlets in all habitable spaces.IRC 1507.3.4.4
A 30"00" level working space shall be provided in front of the
control side to service appliances. In attics and underfloor areas,
a passageway a minimum of 30 inches high and 20 inches wide
traveling not more than 20 feet from the access shall be provided.
A 24 inch wide solid pathway shall be provided in attics. A
switch -controlled luminaire is required at the passageway opening
and a receptacle outlet at or near the appliance. A means of
electrical disconnect is required within sight of the appliance or
the breaker is to be capable of being locked in the open position.
1IRC M1305 IMC 306 NEC 422.31(B)
Provide the combustion air required for the proper operation of the
appliance(s). The minimum required volume per the standard
method is 50 cubic feet per 1000 BTU/hr. Where exhaust fans,
clothes dryers, and kitchen ventilation systems interfere with the
operation of appliances, makeup air shall be provided. Fuel -fired
appliances shall not be located in sleeping rooms, bathrooms,
toilet rooms, or storage closets unless specific installation
requirements are met. IRC G 2406.2 G2407.4 G2407.5.1
11FGC 303.3 304.4 304.5
An exhaust hood/system of >400cfm installed or required by the
range or cooktop manufacturer must be provided with makeup air
equal to the exhaust air rate. IRC M1503.4 IMC 505.2
Provide required makeup air in the laundry room. Louvered doors
or openings/grilles into other spaces may be used to meet the
requirements. Other limitations may arise if a gas dryer is
installed. IMC 504.5 G2407.4 G2407.9.1
Dryer ducts shall terminate outside of the building, 3 ft. from any
openings into the building. The tennination shall have a backdraft
damper and no screen. The dryer duct shall be a minimum
.016-in. (27 ga.) thick, a minimum 4 inches in diameter, have a
smooth interior finish, have sections joined with the insert end in
the direction of airflow without the use of fasteners, be supported
at 4 ft. intervals, and secured in place and protected by nail plates
that extend 2" aboveibelow bottom/top plates. The joints shall be
sealed with UL181A listed mastic or tape. Dryer duct maximum
lengths are 25 ft. for electric and 35 ft. for gas with deductions for
fittings (or sized/length per manufacturer). If concealed, the
equivalent length of the duct shall be permanently labeled or
tagged within 6 ft. of the dryer connection.
11RC M1502 M1601.4.1 G2439 IMC 504 1FGC 614
�Hydronic heating system piping shall be tested at 100 psi water
pressure or 1 1/2 times the operating pressure, whichever is greater,
for a minimum of 15 minutes. Piping embedded in concrete shall
be pressure tested prior to the placing of concrete and be
maintained at operating pressure during concrete placement. The
test must be observed by the Building Inspector prior to concrete
placement. Note: a means of providing outdoor air per IRC
R303.4, M1507 and IMC 403.2 is required. IMC 1208 - 1209
Refrigerant circuit access ports located outdoors shall be fitted
with locking -type tamper- resistant caps.
IRC M1411.6 IMC 1101.10
installed on a floor level that is lower than the next
upstream manhole cover of the public or private sewer shall be
protected from backflow of sewage by installing an approved type
of backwater valve. Fixtures on floor levels above such elevation
Ishall not discharge through the backwater valve. UPC 710.1 1
Vent all plumbing fixtures through the roof per UPC 906.0 or
with a loop vent per UPC 909.0. Air admittance valves are not
penuitted unless first approved by the Building Inspector on a
,case by case basis.
Water heaters installed in attics, attic -ceiling assemblies,
floor -ceiling assemblies or a floor/sub-floor assembly, where
damage may occur from a leak, shall be installed in a watertight
pan made of corrosion -resistant materials. The pan shall have a
minimum3/4" drain and the drain shall terminate in a visible
location. The drain cannot empty into the crawlspace beneath a
building. Discharge from a relief valve into a water heater pan
shall be prohibited. UPC 507.4 UPC 507.5
Access will be required for the whirlpool/jetted tub pump and the
tempering valve for all tubs. The tempering valve may also be
installed at the water heater. UPC 409
Showers shall be a minimum of 900 square inches and be capable
of encompassing a 30 inch circle. The shower receptor shall have
a finished dam, curb, or threshold between 2" and 9" above the
top of the drain. The floor of the shower shall slope a minimum of
1/4" and a maximum of 1/2". Lining materials for built-up showers
and shower seats shall be sloped, extend upward 3" above the
horizontal surface, and over the top of the dam or threshold.
Shower receptors shall be tested by filling with water to the top of
the rough threshold while plugged at the drain. Protect the weep
holes in the sub -drain clampmig ring from clogging.
1UPC 408.5 - 408.7
Main building shut-off required on water supply line. UPC 606.2
Pressure reduction valve on main water supply line required by
City code.
Vent hot water tank relief valve directly to the outside.
UPC 608.5
Hot water heater must be seismically anchored or strapped at
points within the upper one-third and lower one-third of its
vertical dimensions. At the lower point, a minimum distance of 4"
must be maintained above the controls with the strapping.
UPC 507.2 1
All pressure absorbing devices (e.g. air chambers, mechanical
devices, hammer arrestors) shall be accessible or installed per
manufacturer. UPC 609.10
JMimimum I" air -gap required at dishwasher. UPC 414.3
Hose bibs (exterior faucets) are required to have a permanently
affixed anti -siphon device installed. UPC 603.5.7
Soaker and jetted tubs shall be installed and supported per the
manufacturer's installation specifications. UPC 409.6
Dwelling/garage separation shall be maintained by installing 1/2" gypsum
wallboard on the garage side from the foundation to the underside of the
roof sheathing. Ceiling of garages with habitable space above shall have
5/8-inch Type X gypsum wallboard attached with 1-7/8 inch 6d coated
nails or equivalent drywall screws and the structural elements supporting
the ceiling protected with V2 gypsum wallboard. Enclosed accessible space
under stairs shall have walls, under -stair surface and any soffits protected
on the enclosed side with V2" gypsum wallboard. Water resistant gypsum
shall not be used as a tile backing board where there will be direct
exposure to water, or in areas subject to continuous high humidity
,(showers, etc.). IRC R302 IRC R702.3.8.1
Fireblocking shall be provided to cut off all concealed draft openings (both
vertical and horizontal) and to form an effective fire barrier between
stories, and between a top story and the roof space. Fireblocking shall be
provided in wood -frame construction in the following locations:
1) In concealed spaces of stud walls and partitions, including furred spaces
and parallel rows of studs or staggered studs as follows:
1. 1 Vertically at the ceiling and floor levels.
1.2 Horizontally at intervals not exceeding 10 feet.
2) At all interconnections between concealed vertical and horizontal spaces
such as occur at soffits, drop ceilings and cove ceilings.
3) In concealed spaces between stair stringers at top and bottom of the run.
4) At openings around vent, pipes, and ducts at ceiling and floor level,
with an approved material to resist the free passage of flame and products
of combustion. For additional requirements see IRC 302.11
Draftstops shall be installed in combustible construction where there is
usable space both above and below the concealed space of a floor/ceiling
assembly, so that the area of the concealed space does not exceed 1000 sq.
ft. and shall divide the space into approximately equal areas. Where the
assembly is enclosed by a floor membrane above and a ceiling membrane
below, draftstoppIng shall be provided in floor/ceiling assemblies under
the following circumstances:
I.Ceiling is suspended under the floor framing.
2.Floor framing is constructed of truss -type open -web or perforated
members.
Draftstopping materials shall not be less than 1/2 inch gypsum board, 3/8
inch wood structural panels or other approved materials adequately
supported and installed parallel to the floor framing membersIRC R302.12
ADDITIONAL REQUIREMENTS
Height verification shall be done by the applicant's agent/contractor and
observed by the Building Inspector on site. The agent/contractor shall set
up the equipment (transit/builders level), establish the datum point, and the
point of average grade. These items must be consistent with the approved
plans. If the proposed height of a building (as shown on the plans) is
within 12 inches of the maximum height permitted for the zone, an
elevation survey is required. An elevation survey consists of three
components to be conducted by a licensed surveyor. 1) Prior to
construction, the surveyor shall establish average grade as specified in
ECDC 21.40.030, and shall establish a reference datum point that will be
undisturbed and can be freely accessed. 2) The surveyor shall locate the
elevation of the first floor prior to the City under -floor inspection. 3) A
final letter of height confirmation shall be provided upon completion of the
structure.
C)
00
Cq
CD
E 7T
-t
Z
C
E
$a.
C)
;>
U a)
0
Z
Z
0
U
Z
Z 0
0
U
�4
Z
U
CN
2
.
A.
I . ,
I � -
� � �. I � �
GENERAL � � . � . I .-
, - _ .
4. PO.-ticrid Cement shall .conform to ASTM 0-150, Type N" W/ water cement .
. . I I I
ro0o. less than 0.45 � �
- �
5. form to ASTM C-33 and � �
Aggregate for hardrock concrete shall con � � -
aggregates for light weight Concrete shall conform to ASTM C-330. I I
� I I I
� - 11
�
I Exceptions may be used only ,.With'.. permission of the Structural Engineer. . I I
. I
� . I ,� mixing operations I ; etc.: � shall conform to ASTM C-94. � -
6 Concrete I I 11 I 1. . I I I I
7. Placement of. concrete shall conform to ACI standard 614 and Project I I I 1
speciRcations. I . 11
a. Clea, cuverage of concrete over Cuter reinforcing bars shall be .� as follows: , I . 1
I ...
I .
.. . .
I Concrete poured directly against earth - 3 inches cigar to reinforcing .
�� � .� .1 . .
Structural slabs - ,3/4 Inch clear (top and bottom) Formed concrete with � � � . .1
I :r
ea Ih hackfill - Z inches clear � ��
9. All reinforcing bars, anchor bolts and other concrete inserts shall be well I - � 1: :
red in position prior to placing concrete.
� scom . : � . .
�
1 0. Provide sleeves for plumbing an electrical openings in concrete before I , , - I
, . I I I
plac!ng. Do not cut any, reinforcing which may conflict. Coring in I �
I - itted except as shown. Notify the Structural Engineer : -
- ,
I con.,j at(. is not perm . :
in ,d�/,inde of conditions not shown onthe clruwings� I I � � � � ::
lil.CoriJult or pipe size(O.D.)sholl not exceed.30% of slab thickness and shall � �
. I . I � ..
,r � � .,
be ,laced be ween the top and bottom: renforcing,unless specifically � : , � I I
deto.i:�,i ntherwise. Cancan- trations of conclults.ar ipes shall be avoided � 1.
sx,_�.pL wilere detailecloopenin are hprovided I I
12. Modii'un of elasticity f concget an st 'd in. accordance with . I I �
.1 re a, w te a , , � . ... - I � . . ..
AS`R� r--469, shall be.,Ot ,least the value given by the equations in
I I I . � � I I .. .: �. .
Sec.Lon 8.5.1 of ACI318.for the specified 28-�- , day strength. , . .�� I . I ,..
I I - .. .
I . .
13.Shrir-kc9,,; of concrete; .When tested in accorclance with ASTM 0�157, , I , . 1''. .
I �Q�in.h.§&,_.h. . 11
sha�l not exceed O.O( � __ - .
�, �F I .
1_4Conc,,,!1uAe, si ------ ----'--- ___�
inn �.. is.-_'Rosed on 3600 psi and 'special inspection 7.secl.irecl.
I - 11 1. �
I Sea sabdrate Inspection note under S101A 11 I
- � _____ __ ------/
-.--. I I
�
_____
� - �. � .1 I I
. I
7. All welding shall be done LISIf,g E70 ,Series Low.. Hydrogen. Rods and be in
I I 11
I accordance with the latest of -the American Welding Standards. I
.. - 11 �
8. Seismic Design Manual ,by AISC 341-10 I -- . . .
A I �
I I -�
9. Contractor to a ecif If. the steel colums are to be fabricated on site
1
.
� 1.
� I . I
... I I I I
. � �
� � -
I I � 11 I
I
. � �
.
I � I
�
I I I I
I
�
�
I . �
. �
I �
I �
� � I
-
I I
�
� �
I
�� I I
� I I
I :: I
:
12. Rim joist to top plate I :
� I
11 I 11
8d t 6"�152 mm.) o.c. I �
3"xi:G131, ndils.at 6" o. a. � .
5-3"14 gage staples at 6" o.c.
I I
,� 1
toenail
I ...
I
I �� �
1, The Contractor shall verify all climensions� 1prior to starting - -
1: � r itect shall be notified of.any discrepancies
.onstruction. The Arch I I - �� � I I , I I ,
I or inconsistencies. I I I � � - , I I
1 2 Dimensions shall take precedence over scale shown on drawings. I I I 11
. I I 1
I
1 3 Notes and details on drawings shall take precedence over ,
I era[ notes and typical. details. I
I gen �
� All..work shall conform to the minimum standards. of the 2015 I
1 4 1
edition of the. International Building Code and any other regulating I
age Coles which have authority over any, portion of the work �cnd
I those codes and standards listed in these notes speclfications.� , I ,,
I I I I I I I � I
I I � I I I I . 11
5 See Architectural drawing for .the following; .
� I I I :
� I I � .
I I
- I
I � ,Size and location of all door and window openings, I
� � I I I I
- � I I except as noted, � I I I I I
11 � � I
. -
� � Size and location of all interior and exterior . � I I �
� pon-In
� scring 'ar'flo.ns I
� I
- S d location . .1i Concrete curbs, floor drains, I
ize an I
slopes, clepressed areas, changes in level, chamfer, �
I
grooves inserts, etc. , I
Size and location of all floor and roof openings, except as. shown.
- I � . 1
I - Floor and roof finishes. � I
I I.. I
I 11 I- Stair framing and details (exceptas shown). , � � I I
I
I I I I Dimensions not I shown on .Structural Drawings. � I I 1
- I
I � I
1 6 See Mechanical, Plumbing, and Electrical drawings for the following: I
� I I I
� � Pipe runs, sleeves, hanger, trenches, wall and slab I I
,- ,
I I I I I �
��� � � openings, etc., except as shown or noted. �
11 I
� � - I Electrical conduit runs, boxes, outlets in walls and slabs. I 11 C
I - � :Concrete inserts for electrical, mechanical or plumbing fixtures.. :
I - .Size and location of machine or equipment bases � , anchor I
�
I bolts for mounts. I I
7 The Contract Structural Drawings and Specifications represent the finished
structure. They do not indicate the method of construction. The , , �
structure
I Contractor shall provide all measure necessary to protect the, . I
. duiring. c I onstruction. . Such measures shall include, but not be limited to,
I I I 1
: , . bracing, shoring for loads due to construction equipment, etc.
11 I
: .. Observation visits to .the site by the Structural Engineer shall not include
inspection of the above items. I
I I I 11 I I � �
� � �
I � � -
I 8 Openings, pockets, etc. larger than 6 Inches shall. not be placed in slabs,
I
I decks, beams, joists, columns, walls, etc., unless specifically detailed on
the Structural Drawings. Notify the Structural Engineer when :drawings by
I I others show openings,. pockets,. etc., not shown on the Structural Drawings,
. � but which. Ore. located in structural members. � I : I I .. I
.11 �
.: I I I
9 ASTM Specifications, noted shall be the latest revision. : � �
I ,
10 Contrafator shall investigate site during clearing and earthwork operations
I as cesspools,, cisterns,
far filled excavations or buried structures such
I
I . foundations, etc. .if any such. structures are found, the Structural Engineer
I I
I I shall be notified Immediately. . I I I 11
, , i - 1
,I Construction materials shall be spread out if placed on floor or roof. I
_'
Load shall �not exceed the design live load per square foot. Provide , ,
, I I I
I adequate.. : : ,
shoring and/or bracing where structure has not attained .
, I -
I I ..., I
design strength, � I I I
, , I I I I . . I .
I I .�
I I I . .
I I
12 Design Code: IBC 2015 1 - I I . .. I .
I
� . I . .
I . I I .
13 Design Loads (PSF�: , DEAD LOAD , LIVE 1. LO . AD : I SNOW LOAD, z
I
I - I I I . I
I . .
I � :ROOF : 18 I I 1. I .
� . ....25: , , , I 11 I
1 20 . ... . . ,,, : ,
� 11 .. -
I . I I
� I . . I . I I :
I I
I FLOOR :: 34 1 � 40 � . .. I I I I
, � �
I 1
I � I �� . I I 1, I I I I I I
I I I I
I red I
,14 Individual piers shol project B" above grade unless approved wood , �
� I ,
I � I . used. I
� or posts
1 �. Top Plates, .laps and inte actions
1"S ,
I � � I - I
I � � . I . ..
2 -16d common
3-3NO.131" nails
3-3"14 gage staples.
I I ...
I .
I I.. . 1 I
face nail I
I I .
�
14. Top plates, laps and intersections
_
16d: common :
16"o.c. along edge
.1 � .
SHOP DRAWINGS . - -
I �
I I -_-
. 1. 11
I
15. Ceiling joists to plate
I .
� �
� .
�
.
3�8cl common
I 5-3"xO.131" nails
5-3"14 gage staples
I
�
toenail
I
. '
1. Shop drawings shall be su6mItted for all .structural items in I I
.
111. ���
addition to items required by architectural specifications. � . ,1
� . I
2. -The. contractor shall. review all shol) drawings prior to submittal. Items not , ,,
I
I I a shall be flogged upon his review. . ... . I
An - accordance with contract drawn*g ..: . ... .. I
: - : ,
I I I ..... . .... I
I % 1
3.: Verify all dimensions with Architect. I 1. .
. I .. ...
I ..
.. .
.1 ..
� 4. Any changes, substitutions 6r deviations from original contract drawings I . ...
� . .... .
.. .. �
' ' . .
. .. �. I.. I
shall be grounded or flogged by submitting parties, shall be considered �, . � " .
I . .
1 ... . ...
I approved after engineers ,r,-,view, unless notified otherwise. . . . . 1.11
I . . ... .
I � , . I . ..
11 .
I : : :::, , I 11
5. The engineer has the right to approve or disapprove any Changes to : . � . I
- . I .
I . Shop drawing review. .
original drawings at anytime before or after I
� I �
6. The shop drawings do not replace the original contract drawings. Items
omitted or shown Incorrect; ' / and are not flagged. by.the Structural Engineer
or Architect are not to be considered changes toorginal drawings.
7. The:6dequacy of engineerir,3 designs and layout performed by
the others rests with the d!asigning or submi a
tting authority,
I .
8. Reviewing is intended onIv ,�q an .old to tile contractor in obtaining correct
- I
shop drawings. Resipong6iii,/ for correctness shall rest With the contractor.
�
16. Continuous :header to stud
-
4 Ball common
I ,
,,,,,
toenail
17. Ceiling joists, lops, over partitions I
: . - (see section 2308,10.4.1, . :.: ..
table 2368A04:1) ...
I . 1
I �
3-16d common. minimum,
Is �
to ,, 2308,10.4.1
I
4�3 xO.131' nails
4-3"14 gage staples
� 11
�
�
face: nail
� I
I I
� 1
I 11 I
I - rafters
18, Ceiling: joists to parallel
I I
.1 (See section 2308,10.4.1, :
table 2308.10.4.1) :, _. . ,
.. I �
I 1 I I �
I 11
3 I
-16d common minimum,
table 2308.10.4.1 �
I �
�
4�3NO.1131" nails . � �
,4-3"14 gage Staples ,
I . 11
11 �
� I 11 - :
face nail. � I
� � � I
� � � �
�
I
� .
19. Rafter to plate - . _; I 1.
(see section 2308,10,1... _%
table 2308.10.1) : ' - ,
I I I I . . .. �
3-8d common , ,
3-3"xO.131" nail. . I I
I
33"114 gage soplas I
.. I
face nail.
I I -
I I �
� I I
20. 1 " brace to each ,stud ,and plate
�
�
I I I I I
2-8d common : , I
I I
2-3"0.1131" nails . . :
2-3"14 gage.stoples face nail
- - I
�.� , 1
". I .
face nail,
I
� � I .
L. ,;
-
. ...
1; I I I - �. I".. � ,� I .1
�; �' .. I I
I I
I $TATEREIN OF SPECIAL INSPECTIONS :.. I -
,� . - I �,, � . ... �.
;- � I
I I
21,. 1 " x 8" sheathinq or less
I to each bearing wall :
- I I I
2�8d common , I � I
. .
I ,� �
face, nail :
. I . .
I..
I � I
I - I
I This statement of pecidl lns.,�ection is submitfed ,in fulfiflment of the requirements �
ofABc Se 70S , - I , . � I �
ctions 1 4.3. th�, ',,,flowing attachments summarize the special inspections
�, I I 11
and structural tests required 'or this project. :
11 . I I I
These. requirements have alcc.� been made pq I rt of the approved plans. I
I
The ow I ensure that the construction
, bar recognizes his or :,gr obligation 'a
lies with the approved p,--.,mit documents and to implement this program of
comp" a �
special inspections. In porti I fulfillment of these obligations, the owner will retain
� � S I
and direct!y.',p for the pe6al inspections as required in IBC section 1704.2
I 9�
11 �
Special ,inspectors will refer t., the approved plans, and specifications, the above I
, , ,
referenced a had les, and. the relevant IBC sections for detailed special
I I I IP1 P
inspection requirements. any. 6dditional tests and inspections required by the I
.1 - I I I 1. � I - �
I .
* nd specifi6q�iGns will also be perfo ad,.
approved plans a rrn
.1 � I ,
. �
1. . I I I I I
Interim inspection reports I shW be .submitted: to the building department and .. .
I I
ach-lawin, Inc. ;6, j&( C� section 004.2.4. a final report - �
to hohb - ocordance with IB I I I . I
-hunting required .special Inspections, testing, and ...... I
of special inspections docut . �
I
� . � .
correction of any deficieraiies noted in the inspections shall be submitted prior .. I
.1 I
.
to issuance of a certificate, of use and occupancy. .. -
I . . ,�
This plan has been clevelopod,; with the understanding that the building official will: �
I 1. Review ancf.approve the quali[ication of the special inspectors performing the
11 I , I 11,
I I
inspections I � I I I I � �
I I I I
. I I �
2. Monitor special inspection octivities to assure compliance. with.. project requirements. �
.1 �
. �
I I . .1 . � :1 .... - I I
I I 11 I �
. I.. - I .
3. Review submitted inspec�lr,, Qrts,., , , . . 11 1 I
n rep " . . . I
, , I I I I .. I .. I I 11 -
: . I I I I I I I I I'll., .11
I I 11 I 11 I I ... .
4. Perform inspection . � I .. . 11 I I - . . .
. � � I � .. �. . . .1
I � .. .. . . . . . . .. .
� �. ... . . .. � .
I— I � . . . . . .
. .. .. . . .
. . ..... ....,
. . . .. .....
SCHEDULE,,,.QF SPECIAL; INSPECTIONS,::......... . .. ... . ....... ....
....... . .....
....... ... . r ....: .. .
... 1. . I - I....... I 1 ._ I.. 1 ... .. .... .. I . ... . I
. � . - - ... .. ..... . .... . ... 1.
I , , . ............ .........I
. . . .... . .... .. I
ction � reclyaq .1 . . . . :. . . . .. . ..., ...
Inspe f I . .. .... ..... . . .. . ...... .
. . . 1. .. .
. X I . I ... I ... . ... .
2111 I .. . : I I I I I - .. .
I . . I .11, I I I I . .
I.. 1. I I . ,
C - continuous inspedt.6h . I 1. 1. 1.11 11 I - I .1 .. 1. .1. I .- I
. � I I I I - . - I..
I 11 I . . � I � � . � � I
'_ -; : . ., I
P - periodic inspection . I I I . I 11 I I
. . . � I I .
- - � � _ � .
X - denotes in )action 1iict -s either ond" a , � , , I
' Aime or; at, _ I -
. I I
I , I
sr I I I I . 1. , I I . I I
I I 11 I
frequency defin,d in �,-ne other ,manner : , : , , : . - � I I
1, I � . . . ... ... . � I
'i p - .. . ... ..
.1 I . . ..
�
I T__
. F.-I SEISMIC DESIGN DATA
I I I
-
-
22. Wider than 1 l' x 8" sheathin
to each bearing . I 19
I
� - I
3-8cl common , I 11 I : I
� I I I I
� . I
I I . .... .. .... 1. I �, :
face nail .. .. :. :
. . 1. �
1 ... .. :
I . . .
. . .
I
1. Seismic importance factor : 1.0, Risk Category : Ill
2. Response spectral accleration Ss(D.2 Sao) =1.33g ;S1.(1.0 Sao) = 0.520g
I I
3. S;i--,Flc,ss : D I I I �
. . 11 .
4. Basic selsmic-forc67resisting system..(MAIN BUILDING): z 1:
11 .
Btu walls with Sheathed with wood structural. � I . .
dpa Ya1L_s4s_t_em_, Light frame I I I I � I .
- I
11 � .
I panels (R=6.5) .. . 1, I I .
11 .. ....." ... . . . . . . .
. .
. ..
.
Design base shear (V) : CsW = 0.1364W . . � .. . .. ..
11 I I I . . .
: ..
Analysis procedure: -Equivalent lateral force ,procedure per section 12.8 of : . .
I I I . I
. . .. 1
I I -, -
I
23. Built-up comer studs � I
I I I � 1
1
I . ..
1 6d com man I I 1
3"X0.131" nails
3"14 gage staples. , ,
I .1 �; ,
24" 0.0; I I
I W! O.c , I
16" D.C. I I
-
.. .1� � - � I
24. Built-up girder and beams
.. .. -
.
. . �
. .1 .
. I I I �
- I .1. . �
. .
. .
� . � I
.. I
11 I . .1
I I .. .1 I
. I I 11 .., .
. . I I . .
. . I I . .
I I I I
a.. .
20d common 32" a. .
' "
3'xO.131 �
�_3"14 nails at 24" o,c. 0
t 24" c
gage staples a I "
2 -20d com I man :
3-3::xO,131" nails , I
I I
3-3 14 gage staples .::..:.:..
face toenail at top
and bottom
staggered, on. '
' opposite sides �
� �
face toenail at ends
and each splice
-
I I I I I I-. I
I 1. .. I
25. 2" Planks . . � -
� � I I I I
. .
16d common . ..: .
� �
at each bearing
.
-
11:
�J
___
. I I
I I I 11 I I
WIND DESIGN DATA, � .
1 1
I -_
- I . ... .. � .
� � .
� :
26. Collor tie to rafter .
11 I I . I
1 1 .11'...
. .. . .
.... I
I . . ... .. ...... . .
. . ... . .
. . . � .
� .
3 � 1 Od c 1.
mmon ;
4-3"xO.1031" nails I I
4-3 "l 4 staples face noll
� �
,face.. n oil
I
� � -
- . I
� 1.1 Basic wind �sipeed VuLT : 1 1 0 MPH , � � .� . I
. 2. Wind , I . I I .1 I 11
Imparritance factor : 1.0 - ..:.. 1, - .
. . . I 11
. 11
: .. .. . I
- . . 1 1
Wind exposure : B . I I I . . I I � I � I
3* 1 1 I
I I I I
. 4. In 1 e�ncl 'pressure,, coffegient ,± 0.18 ; , 11 I
I . . End
0;16 PSF(Interior Zone) +16.00 PSF (
5. Design wind pressure at Exterior Walls = 2 . I
I : �
I I � �
I 11 1: 11 1111
: Zone) I I 11 11 �
.. 1
I � -
I .
I � . . .
-1p... .
27. Jack rafter to�,V . - I I
I I I 11 I
,: I I I
11 .. . I � I , I �
. I
11 -
I I I . . :
I I I I .
I I 11 I 1
1
gage
- - -
1. I
3-1 Call common, . � I
11 I
4-3NO.1311" nails � . I I
4-3"14 gage staples , : ,
I I
A66 nail
I I
. �
- .
face ,nail
� I 11, .1 1
I I I I
� �
I I
I .1
1
I
Js
is
kl< I
�
W
KK
.
, I
, , 11
I I
I I 1
I
- .
I .1
.. I..
. I..
, .
.
. , I
I .
.. .
1.
I . ..
::.. � .
... .
.
I I
� I
I I
� �
� -
� �
.1 �
I . .
: �
,
11 .
I
� I I
. .
.. �
I : ,� �
. �
I
I I
q.,
I
,
:
I
�
. .
I
�
I I
1.
P
51
.2
I
A
�:
�
M
Q
.9
�
�,;
.
: .., I
. .
I I I
.1.
1,
f2
i�
� M
9
�:
0�
I �
R
E
oz
�
� �
1
I
I �
.!3,
E
c,
9
,
C�
�
R
5:
,
M
P
6
2
8.
-
�_
a
� M.
W
ig
Z
<
5
:d
0
�
<
a,
I
<
6
Z
=
I-
,�
IS
�
0
=
9
=
o,
2
r-�
SQ
I
I
I
I
I I I
I
�
.
9
re
Z
2=16d common . I .
3�3NO.1311" nails :
11 - I
3 -3"l 4 gage Staples
I
,
.. , I 11 11 . I __ -
____ ��� I I � I
� ;; I I 11 I I I , � � I
- I � � I
11 �
- I ; I �
I . I � � � � �
11 I
, . H. I I
� i -
� � I
I �
. .
28. Roof rafter to 2-by ridge beam
� � 1
,
I ' ' I
�
I I I I
2-16d cornmon I �
3-3NO.1131" nails,
3-3.'! 14 gage staples I
11 ''I I -
1 1 ,
toe nail
I
face nail
I
1. Frorning lumber,pholl be Douglas Fir-Larch(North)No. 2 Grade, or better( I
I � I I I
I I
� !X61 D,6#2 )� , r':!;; 1, I � � .
�e 1/16" -tighten
,16s sh-all` 6 maximum larger than the bolt size. Re
2. Bolt sic �
I
I oil n; i�z pri'6r:'to closing in. � � I
3. Stejf,.�.,.d"cut,washers shall be used under bolt heads and nuts against wood.
� I
JI �,, z, or P161:qg, resting on concrete or masonry shall be pressure 1
4. A I
I tre,�,Led Qo6plas Fir. Bolts shall be placed 9 inches from the end of a I
.1 � ' tfb�, a notch greater than 1/2 the width of a plate, and
plate,00r ,
I ,
spread at 16turvals noted.
� I
xcept where shown in details. Obtain �
�
5. Do not notch joists, rafters or beams, a � ��
engineer's approval for any holes or notches not detailed.. Holes through
a 11
I hall
Isille. plates. studs and double plates in interior, bearing and shear walls I
C f I
not ;�-_aecl 1/3 the plate width. Use bored holes located.in the center o , . 11 I
I " I
I
the stud or plate. I I 1
16. Approved cross-br;dg'ing or solid blocking shall be spaced as follows:
I n 8-inches in depth, at 10 feet o.c. maximum.
I For Rafters more tha
I For floor joist more than 4 inches in depth, at 8 feet o.c. maximum.
, .
17. Nailing schedule per 2015 Edition of the International Building Code, Table
No. 2304.9.1 Unless noted otherwise. ,� I
��� � I
� � � �
� ,. 11 �
I
I
m man I'll
� 3-3NO.131" nails I
3 -3�114 gage staples ,
I ��
29. JOIST TO BAND. JOIST �
I
�
3 -16d common I
5-25NO.1131" nails
5-3"14 gage staples �
I
I I
� face nail
B. I
presure ,treated .are
I � - � I I I
I
. . I
. .. 1.
.
FOUNDATION � I - . I
11
� .
- I
NOTE: I I
- A. Common or boK nails are permitted to be used except where .
I
I otherwise stated. .r., ,s I I
� ermediate
B. Nails spaced at +3 ,inches on center at edges, 12 inches. at int
-
,supports except-*'5. inches at supports where are 48 inches or more. For
I I
� -al Panel and particleboard diaphragms and shear
.nailing of wood,structui I �
walls, refer to Section 2305. Nails for wall sheathing are permitted to
be common, box or Cos'
C. Common or deformed shlnag�k � I I
D. Common . I I 1.
E. Deformed shank I I I..
. . ..
. .
F. Corrosion�resistant siding nail. . I
G. Fasteners spaced 3 inches on center at exterior edges and 6 I
inches on .center at intermediate supports.
I I
I H. Corrosion-resistont roofing nails with 7/16" diameter head and 1-1/2".
I �
, I I I I
Is I I
: , .1
,. C grths for 1/2" sheathing and. 1-3/4" length,,for 35/22" sheathing. I I I I I 1.
69r 0 !on -resistant staples with nominal 7/16 crown and 1-1/8" � �� .
, . - - .... I . .
ength for sheathing and 1-1/2" length .for 25/32" sheathing. 11 : , , - , - � 11 11, 1
I I ,
11 1. : -
I Panel supports at 16 inches (M Inches if strength axis in the , � ::
long direction of the panel, unless otherwise marked).
J. Casing or finish, nails speed 6 inches on panel edges, 12 .
I inches at intermediate supports. , : � �
K..pcinel Supports at 24 inches, Caging or finish nails speed 6
.I inches on panel edges, 12 inches at intermediate supports.
I I
L. For roof Sheathing applications, fasteners spaced 4 inches on
I 1. , I
11 center at edges,. 8 Inches at intermediate supports.
. M, Staples shall have a minimum crown width of 7/1 G".
N. For roof sheathing applications, fasteners spaced 4 Inches on
I I
I �
center at edgei . �
1 8" at Intermediate supports
O. Fasteners, spaced 4 inches on can r at edges, 8" at Intermediate
� te . I
supports for subiloor and wall sheathing and 3 inches on can ter at
I I edges, 6 inches at Intermediate supports for roof sheathing.
, 1,
8" CtL
P. Fasteners spaced 4" on. center at edges, intermediate supports.
Q. Where a single 3-inch nominal sill plates Is used, 2-2 Od box end
I I �
nals shall be vubstituted for 2-16d common end ,nails found in
.
I -
line 8 � of nallinig schedule. � - �
--- . . . , I .
' '; z 2 15: IBC 1705 . I I
CONCRETE CONSiRV � PER a .1 . ." I-,
6 it � I . .
, , , ,3
. - - I .. 1. . . � � I
- . I I I . . . .. . I ,
.1. - . . � .1 . 1. . : .. . �
. , - ,
- , T - I 11 . . . 11 I . .
TAJ3LE 1705.3 CO 0 I L I I I 11 . ....... .. . I ; ': . , .
11 1 7 11 . 1. 1; _ I I ; . . , ,;, : . ,
I I � - . I 11 .
� . I � �
I
- I ��
Footings are designed in accordance with recognized engineering
1 � � �
: . ctice for soil conditions : � . �, .
pro I �
I BEARING = 3000 PSF� AS PER SOIL REPORT BY!
SOIL I I I
I GECTEcH CONSULTANTS. INC. I . I I I I
1 2401 10TH AVE. E, SEATREt. WASHINGTON 98102 � � I I . I I 1,
I
- P � � I I I
ROJECT NO.- JN 18021 11 .
:� � � . I I I 1
OATED- JANUARY 25, 2018 � I I I I 11 I
. I 1,
I . I I I I
I PHONE NO.- (425) 747-5618 - I 11 "I'll 1
�
. 2, Contractor Shall provide for proper cle-watering of. . I I
I . I �
� - I
,� �
'excavation. from surface water, ground. water; seepage, etc. .
I � �
, � � . . I I
3. Footings shall be placed and estimated. according to depths �
� ..
shown on the drawings, and as recommended in, the soils . .
I � .
� I � . I
: . � � I
report. I I . . .
I . -
0 Aing backfill and utility trench backfill Within building area I I I I I
� 11 I
4. F ( I . .1. I
hall be mechanically compacted in layers.. :Flooding will not .. .: I
a .
� . - .. . .. ..
be �permitted. � �� I .. I I .N. . I
� I � -
5. All abandoned footings, utilities, etc. that interfere with: new I I
� � � I I . . ,. I I I I I
I � . I I 11
ristructim shall be removed. I � � . - . . 11
cc .
6. Preparation of soils benecith building footi gs and ,.floor slabs, I I I I
I I I
go,n � I 1 I 11 1
I
shall be in accordance to the project Is report, � I I I
I I
, I I
I 11 �
"I'll, �
- - ;. . I
.
ITEM .. : I . �
, ,
FREQ.
1.
. .
. �:: i :.:.: NOTES I .. .1
. -
___ - I I �
rix ai,js%� ,
1. Verify use of required ml .in.
.-
�P��
...
. .11, I I "I'll
I -1 4:26.4 :. I .. 11 .
ass ACI 31 8 -
I I . . .1
2. At time fresh concreto. is samplod: fabricate,
specimens for strendth Aests, perform slump
and air content tests, and determine the .
. ,, . .
I .
- .
temperature of the concrete.� I I
11
G
.
. .
. . .
See_ASTM C.172, C . I.. I I'll
31; 1 - 1, I I
I I . . � -
I 11
..
ACI 318-14�26.112 . .. . . I
I . ... .
I I I
I I
� � .
I I
. . -
. I
. � 1:
.
. . :�
�
. :
-
. I
�
�i
��
IM,
I I
I
�
6
19
A
I �..
I
,�
11 F1
*
.
�
I ��
��
�f
, 2�
I
�'
-
� R
�
.4
0
1i
:
3. Inspection of concrete placement for .... .. . .
..
I . ,. - I �
..
proper application techniques. - I - 1.
--l-, .
-
. C
- ....
see ACI 318-14:26.5.2 ., :. . .
� � I
� �� � �
- .. - -
I .
. I I
I I - - ,. I . I
.1
I
I EDULE I
G SCH I
,-NAILIN I
.1
I I.. . I
proper, I 1. I
1, I . I
11 1. 11.1
4. Inspection for maintenance (If . I :11
.
ecifled curing temperature and ..
: sp 1.
I : � - _
1''..
- ...
, techniques. I . ,..
. � �
� - ,
11 P
.... .... ..... . .. ...........
..... .. . ..... . ... .. .. .. ..
�. � I I �
� I I I
� I I
' see ACI 318-14:26.5,3
I I
;�ffR
7;iq
[_<
A
,
�
- . .
.
11 I . �
I
MAINLAND
I..,
ENGINEERING
CONSULTANTS
.
CORPORATION ,
� . I
�
Suite 206, 8 3Q312,8th Street
� .. ...
Surrey, B.C. V3W 4GI:
Tel: (604) 543 8044.. 111. .. .
Fox: (604) 543 8104.. ... . 1
. :1 . .
. 11 1. ..
, - 11
�� -
I
---
I � 1,
I CONNECTION I
FASTEINING"m
11 I :
LOCAT16N
___
,
. .
5, Inspect framework for shape, location and
'
dimension of concrete mermnre being
� -
. �
formed. ----
-
P
I
.1 I
see ACI .. I
. 1
318-14:26.11
-
11
I 1. ioi�t to sill or girder
- 11
I I
3-8d common
3-3"xo.131" nails
3-3"l 4 gage staples
- 11 - -
� I � I
- - I
toenail
� �� I
� I
. � ,
�
2� � Bridging to joist
- I I
I - I
I I ,
I I
I I
�
2�8d common
2-3"xO.131" nails
2�3`14 gage staples
� � .
, I
toendil each end
�
-
I 'I'll
I - -
I 1.
.... 1. .. ,�
.
: 1,
� ,. : I
'. �:::
I
ALL WORK SUBJECT APPRIBINED �
I 1.
TO FIELD �:
iNSPECTION FOR PLANS MUS7 BE
CODE COMPLIANCE .
.,
__._._�, - :
1. : ON JOB S�TE
I I I . 1. . I
I I I I . I I � � I
I . .11 . I I 11 . - - ��� ... I
... . I I .
.... . I I I ....... �.. �. � �
. I . . 11 I I . - . .
I I I I - - - � - I
- - I'll, 11, I � I I � � - .... �... . �� - �
I . . . 1.
. .1. .,.�� I
. .� . I �
�. - -.1 �
. . . . . . ..
. .. ... I
.. ... .''..
I , ,.. - I
I ,
.1 - 1, 11
- I .
11 � I I ... - . -1- I ------ 1_._. I
1. - �, . � . � , �. i I �
I I 111.1 .. ".... � , �. , . �
I I I . I ..
I . 1. - 1. - ... -.1. . I
�. 11 - - I——
� - - . I..''. .. �� 1 City of Edmonds Building Department I
I - I ._. . .. �.� .. -
- � . � �. �. . .. .1 .
� � � ,:.%:: .,: ... :F - . _ . I
I - - ... �. .. .... .. .
� . � � ....... . .
I .. ...., .. . . .. .... . .. .... . ,.. . ::.... ,
.1 . .1.1 . .... .. .
. - .11 1. ,.. .. . .... 1. ".. I . I
I . .1 .. ...... ... .. . ..... .'. . .1 . : , 1
11 I . .. ... ..'.......... ...... "...., . .. I
I - - 1, - 111.11 -.11 . ..'', I , ���
11,11111,111,11,111, I 11.1--l'' I - �
- I I .11 11 I 11 I I
I 11 , 11 , I I ., 11 I , I I
I 11 'I'll - 11.1 ." I I �, .11 I 1
I 11
. I I
.11 .. .. I I 11 I - 11 I : : I � APPROVED P A ,
, . I
I., 11 .11::11 I
11 11 __ I I
I
.1 11.1.1 , .1.11 I .. ,� - I -_ I
11 ,".."
..., 11 11 .11 11 I'll., .. .... .
, , _ , , , . I - . ,.
- 11 1, - . - "I'll" 111.11, ., -, . I I.. .1 \
11 I � � . - I I I I
11 1 I - � ::, , , I . - I - 1; 11 I I .
11 I I - - , ,
: I I 11 , - I-, I I I-, 11 I.. .. -.111 I
.1 � . I ,.: �. : ::.: I � V. .: �.� � � � I ''... I
- . I I I
. � .. - - .. �
... . . . . . ... . � . 11
I--, .. .. .. . .... .. . ..... . .1. � 1. .-
I .1 I
I _ .. . 11 - '''' ,. -
I ......1,111,1111 - 11,111,111, 1.1, 11 I I
. ....'....'.. I .1. .111". 11 I.- 11 I I 11 � � � � -
.. ,....... ....'.....1. .. ,' I .. .. .. I
. I.., .. .. .. I ..... . .. . I -, ,. I . :. %;
.11. 1.111, I 1. 11 . . .. .. 1.
I ''I'll", . . - CIT (aply
, . I 'y C
I "I'll" - .. . .1
. .. I
I "',,"", . .1 ... ... 11,
'I'll'' - . .. . . 11
I , . . .... .. .1
1.11'..''. I 1. . .
.. , . 11 ::..,. .11
11.1 I I . . .. .. ... 11
I .11 ., ....
I . . . I "I I I . ... I 1.
I �... 11 I . .: I .
� � � I'll, I I 1, . I
11 . I I
� I 1. I I � �
� "I'll,
� .11, � � 11 1. � � �
, 1 .. ;; , I
'I', I � . --l", � �
- I I . 11 - 1 :::... ,
I I I �.I...., ,,,_' .. ...... - �
I .. I . .1 I ., I ..: . .... .. �
... .. I ...", - I 11 . .. .....
. . ....I.. -, . . : - I
. . .11 . .
. . ... I , I . N : .... . I.. -
. . ... '.1 11.11'' 1. . .... - .. ,� �
� 1.1.1', I'll 11, I .. :.....".1-1111111, RESUB
.. 1. I -
� I I 11 11 . I I ... I I ,,
. "I - 11 1. ,...."""Ill N, _�,
.. � - .
. .. I 11 I I
I .'' I - �
I I 11 I - .
11 I I -
.. "I I I 11 - : � :; MAY 2 8 2019
. - 1 � ,. . . I
�. I.. _; , , I .. .111,
�. ..
.I.... .11,111, I .. .. . .1 � -
, 11 1. . . .. : . :;� -
- I . ....:..::... 1:1 I BUILDING OF
11 .. .... ... - I - .
... ...1.111111111 ". . .
. 1.111, I �: CITY OF EC`MARTN`DEZNT
.. . I , , I I .
... .. .. I .111111 . I
.. I , I ..
.1 .111 I I - - ::. I
, '', I .1. ; :: : . 1 I
1. I .. 11 - . I
, 1 .1 I -,
I I I 11 11.11. I -
11 . .1 11 11
1. I - ,
I .1 1. .. I 1 11 . - �4k�4-,,J
. . . - I 11,111,
, I , I , ... . . � I I
I .1,11" ;. :� � �. �
__ . � :, I I'll. '. :. . _ : ... : :: :, I
, , . 11 . I . . .. I I I
. . . .1 . .. .. . 11 I I
.. . I . . .. .. I I I
I . .
I . . .... . .1. . .
. .. - ,. : , 1. .... - I'll ".. . I
I - �� I I
11 � � I I �
C. REINFORCING STEEL I I
I (for I I
oncrete and masonry) ': I . .1 I � � I I
I
1 - Reinforcing bars shall conform to the requirements Or AWIVI A-0 t.
� I . I
� 11 I
Grade 60. � - �, : ''. 11
2. All reinforcing bar bends shall be made cold. : . . . I
I 11 11 .. . .. -
I I ...
. . .. ..
3. Minimum, lop of welded wire fabric shall be 6 inches., or::, . . 11 1
, � . I . 1:, I -, I .
I
I I . ,
.11, . I I'll., I
1,
one full mesh and one half, which ever is greater. I �
I I
4. bars shall be marked so their identification can be made I I
All 11 .1
I I I ,� . . I
�
when the final in -place inspection is made. I I I
I 11
5. Lap splices of reinforc Ing bars shall utilize the noncontact lap . splice �
� I
. method with a minimum clearance of 2 inches. . I
�� ,� 6. Reinforcing splices . Shall be made only where indicated on the drawing. : �
� 7. Do I ns shall be the same
wels between footings and walls or colurn
grade, size and spacing ,or number as the. vertical reinforcing,
�
� I � � �
respectively. . � �
� � - �
---
,
� 3. 1'x6" subfloor or less to ea. joist
___
4.Wider thanIN15"sul,floor to ea. joist
____
2 -8d common
I'll � :
3�84 common I
face. nail 1
face ,nail .
I -
� 5. 2" subfloor to joist or girder
2�,16cl common
.
blind & fa ce nail
___ �
6 Sol- plate to joist or blocking
I I I
.. ; I I .
; 1
; I I , �
1 � I
I Sole plate to joist or blocking,
� m ...1. �
a. -aced wall panels
. .. . 11 I
� I .:.::
, , , . I I . .....
_5�1_.,ppi
-T-6d at 16" a 'c. �
3�3`xO.11311` nails at B" o.c.
3-3"14 gage staples at 12" a.,.
11 11
11
- .
typical .face nail .
I I .: �::
� . I :
. . ..
,
1. I 11 11
braced wall panels
I I I I
I I . :
. ..
. -
. ..........
� ... ..
. ... ..
.
� I ....
. . ....
PROJECT TITLE, . .
. �� - I .
. . 11 .
. � 11 . . . .
SINGLE. :FAMILY: 1. I . -
- I I , I
1, ...
DWELLING 11 . . ..
I . 11
1. I I
I . I
I . I
15712�72 AVE.:. WEST_
� , �
EDMONDS Wk .U.S.A.
I .. .
. . �
11 . . .
.. -
-
3-16d at 16"
4-3NO.1311" nails at 16"
�
4-3"14. gage staples er 16"
- � P
,a to stud
I 1
I
_ corl,lpon
2-16d
3 _ 3 .0. 1 3 nails at 16"
,
3-3'�14 gage staples
- .1 I
I I
end nail : :. .: ::
. . I
. .
1.
�
� � I
� 1
I LAMINATED BEAMS , (GLULAM) � I I
I -
- I I
� �
11 � � �
��:] PLYWOOD � �, - �
I
_.- . . I
I Siud to sole plate
I .
I
4-8d common �
4-3"xO.131" nails
3-3"14 gage staples I
.. ... .
� .:
. . .
I I
toe nail 11 :,
11 I
I I
11 I I
� . . .
end nail . �,
I I . ... .. 1.
, I 1. ..
I I
1. Glued -laminated beams shall be 24 F-V4 and hove the following I I 1,
� � I � I
� I I
minimum ,properties: FB=2400, psi, FV=165 psi, FC (perpendicular) ,
I I �
I I
....
''I = 650 p I. E=1 800,000 psi. All beams shall be fabricated, using I I .1
! 111.
I I
.:� 'waterproof glue. Fabrication and handling per latest AITC and I
� WCCA standards. Beams to bear grade stamp and. A17C stamp � I
- . I 1,
� �.. 1.
� � and certificate., Moisture content shall be limited to 12% or less. I
�
I
STAMP �
,,,,�1-:, "I L I 1,
I�J� �"��,Z��,'l :�,, � �
ln___,�;, I - .
. �
��, � ,� .
1�'_._ ''I"....
,. - .
I'�', , , . ,- ,
� ',� - , I , I I .. I
11 � �; , ,
I "'], � I �: �, ;,
� -1 � � ,,,
" �
. . ,. .
� 0. 1. 112:, � .
� � - , � I
�� �,
. � 11 , ,,
�
, *;,, - : .
'It., :�
I .�
. i��
� - . .
. �'. ,
� .1 . 1.
, �
� �
-1 D 1514 TI L _5 E P 20111
. I
� � All plywood/uSb shall be C-D interior sheathing with exterior glue
� -
� shall -bear the stamp of an approved testing agency. Lay up
� plywood/osb with the face grain perpendicular to supports, use a
. I mi I nimum of 5-ply plywood/osb. Stagger joints. All nailing, common
.
I . be of the span/inclex. ratio and shall be as
.. nails. All plywood/osb shall
. . I I . I
, I
I shown on plans., I
� .
I
2-16d common
3-3NO.131" nails ot 1 6'. 1
..
3-3"14 gage stopbs � ...: ,
� I
I.: ..... .. .:.
9. Double studs I
11
� : :::: ......
. ...
I.. 1,
. .. I 11 �
I I... 11
� � � � I
- - .:.
� .
1 6cl at 24" o.c.
,J X0.01" nails at 8" o.c. ,
� �
3"14 gage Staples at 8" D.C.
I .� �
� .
� ....
. .
face nail . ...
. . .
. ... .. .
. . �
�
I.. ...
11 :
I ..
I I
I
E.
I ..
I I .
1. I
I . I
. 1. ,
I CONCRETE I I . ... 11
- 1. I
- �� .
I � I � I .1.
1. All phaBqp.of work pertaining to structural steel construction. shall .
.
� eel (latest
conform to the building. code:required for structural st
- 11 � ,
eclition of the IBC Code and Manual of SteplConstruction).
I � I . I � ,
I
.. 2 -36ksi)
. . - Structural steel for plates and angles shall conform to ASTM A36 (Fy
3. Structural steel for pipe shall conform to ASTM A53 Gra de B(Fy=36 ksi
I �
., , in.) and Structural steel tube would be ASTM A500,GRADE B cold formed
in
with FY=46 KSi and all W beams shall conform to ASTM A992 Grade 50
4. All anchor bolts shall be A307, unless noted otherwise. 11 I
I . I
5. All bolts for structural steel joints shall be ASTM A325,unless noted otherwise.
� � � - 11
B. All� welding shall be by welders holding valid certificates and having . .
.1
current experience .in the type of weld shown on the drawing or notes.
� I �
eating agency
Certificates shrill be issued by a approved I - .
.1 I 11 I
�
I I �
� � � - I �.: �:
0. Double top plates I ..
Double top plates
I I .
�.
- � � .
��
16d at 16" o.c. .1, . .
3"xO 131" nails at 12 O.C.
3'1�.gage Staples at 1 2" o.c.
-
11 I �
I
typical face .nail. .
... .... . .
. . .
� . . .
. . 11 . I
I . .
.. . I I I 11
lop splice ,
. �
. . : : ,
I �
. . .
... . I
1. All phases of work pertaining to the concrete construction shall, be. in, ,
� 1 1
� edition)
. ,accordance to the project Concrete" (ACI 318 latest approved , . 1.
withsoils report. modifications as noted in the drawing or specifications. ,, ,
1 I . I 11
2. Reinforced concrete design is by the "Ultimate Strength Design Method". ACI
. 1.
I - I
318-99. 1 1 1 1 1 -
Concrete 28-day strengths and types: 11 I
3. Schedule of Structural.. I
� Location in Structure Strength PSI
�. .... . � � Slabs on grade . I I .3obo
I -
� . . I
� I 1 3000 - ,
- I ,� Footings . .
I : I
- I I :. Retaining wall � 1 3600
11 I . � � �
... . . . �
�. .
. .
. - .
11 I
coNTENITS �
STRUCTURAL NOTES : :
.1 I . .
I .
_��-_l 6d common
12-3"xO.131'! nails
1 2-3" 14 gage staples
tylp. face nail
__
CONTACT: AS
-T-l.BFocking between joists or
,
rafters to top plate
.. �
. . I I
I I----- __ ;: .- 1. � .
.. 11 :: I
- 3-8d common I'll .
3-3NO.1131" nails
3-3"14 ,gage staple
11 .
�� - I
I 11 I �
. I I 11 I �
... .... .111 I I
.1
I
�
toenail �
�
PROJECT NO. I DWG, 1,10�
UR801 I S101 .
.. 11.1
. I., .. . .1 . .
. .
. . 11
. . . .
. .. I .:
I
1. - I
I I I ,
I I , I .
I I - 11 11 I � � I
I I 1.
, �
I I I
� I I
I I I I �
I I . ,;; I
I I I .1 I I
. . . .
I I I � I I I .. : .
I I I I . . .
I I � I I 11 I . I
I I I � I I - I I �
I I I � I .11, � .
I I I I I 1.111, .11 : I I �
I
- I � I I I 11 I I
I 11 .. I
- 11 I I I � � . 1. :.."
.
- -
I . .. .. ... ... - � 1-11 I-- I I ..... ..
I . I :.. . �. , , , - �
I , I
. r ;. .: .:..: .......... I 1: 1. v., �:�: ,:�,;: .. ... . , ''.... �
.... ..... I . I �: : �:;;:: ;;;::::: :: .. I , I :.. I'll. - - :N: . 1; 1. . I I
..... .. . .. .. .... .r "I'll _.:�� : .:;*1 - ... .. - . I.. . I .1.11 .
I I I I , :�,
�
11 �
I .1 I . :_ . .
11 I
. .
. �
� � .
� � .
I , .
. 11,
I . �
I
I
I
I 11
. : :
. .
I
I �
I I : 11 I
I � I ..
I I I � . .1 I . I .
I .
11 I , .
. I .
. STATEMENT OF SPECIAL INSPECTIONS .
I 11 � .
1, 1, I
I 11 11.1.
- ..
I'll, I � I .1
I � I...,
I ..
I I I . .
I I � � � I
. . I
11 I I . I I
� .
. I �
. I I
. .. . .
I
I I I 1
. I
I .... 11 _
. � I I I �
I . . ,
� I 1. ....''
. I . . . I I
I I I � : I
i I I I I � I
� I . I ,�
I I . I ::
.. . .. ..... . - .;;;;;;:_.:...:. . . .
: - ', .. .. .. . .... ..., ..
1- .. .... ..... - ... � I-, 11 - 11 .
I—— I � 1 ...; '' . It., . .......... . . . ; .
....'..."''.. � i::, 1; ,. � � � . "I'll
I . I . I � . I � , : I :;: I ; . . . . , ..: : . : : � z : , I I I . . . . . . . . �
I I I I , , . � � � . . � , � : : i I I � : : � I I I I I . . � . � I
I , , I I ; ; ; : . I I � � � � � � , , I I , I � : : , I � . . . . . . I I I I : ; . : : : . . .
. . I I . � I ; I , I I I , , - , I . . . . . . .
I, I I I I I I . .... .. .. .. ::. , " 1. : -l-, .
I I I I . � � . , � � : : : : .
I I I ; I ; � � � I � I .
: �� ,� ... : "'' _ I � �
I'll I'll.
: ''.
- --..��, I 111.,
- ;, 11 - I ;;;,:::.:; 1 � ....... :, I'll. � �
I � ..... .
, .
...
- 1.
. .:,
I
I I . I . I -
11 I
. I �
.
THIS STATEMENT OF SPECIAL INSPECTIONIS SUBMITTED Ili FULFIL!_MENT OF � � � �
I
111. .. I :
WOOD CONSTRUCTION PRE 2015 IBC SECTION 1705.5 . I .
�� . I I I �
I ..
I � . I I -.111
I � .. . I I .11,
� . I 'I'll
I . . � �� I
I - :1 , - " - ''. � , . 111.
� 11 ....::. ,
:
. :.: i.� :_:: ...
� . : 1: , ,,
I I "Ill : : : 11 ''I'll-
- 11 .:.� I 11
... I .. .. .. - . - I I
.. � ... - I
''I", - �... :..:.:... _,"... _ -, "..''
- - �
I I ., I I � .. � 11
I I .
I . I
. : ,
... �_
,
� � �
..: THE REQUIREMENTS OF IBC SECTIONS 1704.3. THE FOLLOWING ATTACHMENTS
� I
-
ITEM
FRED.
I I : _7
NOTES
� � � .
. I � � � .. . . .. . I I I
I I I . � _-
I � . I
I
. ,:, I
:. ,.
THE SPECIAL INSPECTIONS AND STRUCTURAL.: TESTS REQUIRED FOR
11
I I 1. . .
� . . I I
1. . . I
I . I
I '1111,� ,�, I �
I -
I I'll I'll I I
.
...�SUMMARIZE . .
I . .. ...
THIS. PROJECT, I
Y
1. VERIFY FABRICATOR QUALIT CONTROL
X
NOT REQUIRED IF THE FABRICATOR Is
. I I I
,
. I I
� . � I I I
I I I I :
. I ,�, �11 I ,�
----
I �� - I �
'11, I � 11 I * I
11 I
I 1,
I
I I
.. I
.... I . . : .... � �
. I AN
THESE REQUIREMENTS HAVE ALSO.: BEEN MADE PART OF THE APPROVED, PIL S�
PROCEDURES IN ACCORDANCE WITH IBC
SECTION 1704.2.5
APPROVED IN ACCORDANCE WITH IBC
SECTION 1704.2.5.2
. I I I I . �
I 11 I
I 11 ,��
� � � �
I 11 . . .,
� .
. I I - - I
.1. � I � I I �. . , - � 11 .. . .
''I'll.-
... I I 'I', .11 I � . I-, I I I I �� �� � � � .:...: 11 :: I I
� . . .
�� � I I � I �
�. . � . . .. 1. �. I � I ��
. . .1. .� �. I . .
� � : � . I-, I I I
... "....'.. I
I . . . 11
I I I
. I - I I
I
.1
THE OWNER RECOGNIZES HIS OR: HER OBLIGATION TO ENSURE. THAT THE
I ::., 1"...:
. I , ..
I I I I 11; I -
I I 11 ; I-;
I 1. . I I
� � I .. . - I'll, . . ... I I
I I I 1. I I 1- I-—
- : , I.. I I I
� . . I I
I I
I I
I .
-
-WITH THE� APPROVED PERMIT: DOCUMENTS ANI� TO �
CONSTRUCTION COMPLIES .
2. INSPECT SITE -BUILT ASSEMBLIES: . : .
I .. . . . .
� . .
I SEE IBC SECTION 1707.5, 1 0.1
.
I -
I - I
I I I I 11 I
: I I
1; I . . ., .
I 1. 11:; 1; 111. . . .11 I I
� I . I I I I - :;:: .1. -, I
- I—— - ; ,:.;: ,::,:.. I 'I'll - 1 � 1,
I 1.11" .11,11, 11 .1 I I 11 11
I - I I'll, , , 11 -
11 "I'll 11 I,-
I I . . I
I
IMPLEMENT THIS PROGRAM OF SPECIAL INSPECTIONS. IN PARTIAL FULFILLMENT
. . I
I . .. .11
. ..
-
.
I I . 1 -
I . I �
I
11 I I I I 1; ; 1; ,;: ''I'll-- I
I I I I ;;;�_::.. I 'I'll"",
11 11 � I I ;; I "I'll,".... I 11� 11�1111 I 11 I .
� OF THESE OBLIGATIONS, THE OWNER WILL RETAIN AND DIRECTLY PAY FOR..THE
.
A. FIELD GLUING OF ELEMENT OF THE SLRS. ,
. "....
I 11 .
- .
C
SE E IBC SEC TION 1707.5.11.2
; . . .
. I
I . � I
I
I I ;;_1111
;1 . 11 ;_ 1. . '.. I 1 11 I I
I I I I I
I I 1;1 1;1; 1, ,� 111 . -,"'I'll, - ... I I
I I _--I'll, I... _11,11"..1. I I I
- . - � I -
I ''I'll I ,; . ",,,,", �. . I'll 11
I
I I -
� . I
SPECIAL INSPECTIONS AS REQUIRED IN IBC SECTION 1704.2 .
. � I
, � . � �
- � .
I I I
I . . I
. I
11 -
I I
- 11: - .11,111.111''. _
I I I 11 I - I I . . I. �, 11 I I
I I I I—,; I I I - �� ,:
- I - 1, -
. I .111, - I 11
1; I I I 11, . 1. 11 .1 I I
. I 11 I I ""I", 1. 1. - I I ..".".,... I
I I I I - 11 .1 I
I .
I
. � . � I
I - . .
� �
SPECIAL INSPECTORS WILL REFER TO THE. APPROVED PLANS AND ; ,. � ��� ..
�.. � � I .
... -
� . .. .
SPECIFICATIONSf HEDULES, AND THE �. .... . �
I � � � �. I I
. .
� � �..
B, NAILING, BOLTII,IG, ANCHORING, AND OTj-IER
- - I I 11
p
SPECIAL INSPECTION IS 1, ,IOT REQUIRED
. I I I 11
I I I
. . . . :::,
I I I :
. I I I I 11 11 I I
I .....
I I
1 1 1 1 1 1 11
I
, . .... .
. . - - 11 , I I........ .... I I .. 1.
.
- I I I I I � .... ..... . . .:.i: �� : !� i� :illi;:i;:�:]]::�] � j,�:!, .j::i:1: 11 . .1
I I I - .1 ......... . "I'll, .... ...
� - 11 . :::.�: � _� � I . I � � - � ...."
., . - I .I.... .I....., ..... I
I I � , - - .. .- �:� :1 . .. .... ::::::::: I.. I'll - 1.
11 ; � I - .. . ... �..� - � .:.:.:::::: � 2 . .......... - - � I... . -
I . . I � I ........ . - - I -
I - I � 11 . - � .. ..... ..... ... 11.11,111. . I �
. . I . I I I I I - � � .: :: ::, � �, ..............I.- , , I..
11 I I � ... � - I .... ''I'll,
I I ., 11 �. .1 I -
1
I .... � I
- .
I ... . .:.. . �
RELEVANT:IBC SECTIONS FOR DETAILED SPECIAL INSPECTION . � I � .
..
�
� �� : FA,5TEI,I1[\ - I G
IG OF COMPONENTS WITH THE SLRS,
-
INCLUDING SHEAR WALLS, DIAPHRAGMS, BRA
I
FOR SHEAR WALLS, DIAPHRAGMS ANE )
SHEAR PANELS, INCLUDING ATIA�HMENIT
I I I I I 11 I
I I I 11
I I
1 1 1 1 1 I I I I . I -
11 ::: �,
. .. . I I I I I I - � � ... :.::.:: : - � I .1 .. ............ . I . . �
:11 I .: ... :.:.:. ,� ".
1. I I I � �: �: .�
11 I'll, � �� I I 1-111,111 I I � � � - . - . . ........., - I ...'....'... -
I I I � I I 11 I ''I'll 11 I - I . :.� , - . ......... ,. I I
I I I I I I I - .. �: � � �. I .. ... - �, ,
I I I I , , 11 � I � � F� � �::, ._� - , �, ,
: 11 ...I.I... . ��� 1. I
I ., 11
I . I .. .
I . ..
. � - I
� I I . �
I I
- I 1. . . .
REQUIREMENTS. ANY ADDITIONAL TESTS AND INSPECTIONS REQUIRED BY:: I'll, �
� I . . :::
�
� � I
STRUTS, BRACE, SHEAR PANELS, AND
I �
TO OTHER COMPONENTS OF THE SLIRS
I I I I I I I �
I I � I I � ,:
I I :
I I � : , ,
11 11 �
, I - �� I I 11 ,
� I 11 11 I � � ,;;;,;;, .. � � � - - � �
I I -
"I", .11 I � I � I'll, � r � � :_ ,; . .. ... : _ I'll,
I I - - I - - �
I I I I .: I �� I I I 1.
I 'I, I - I � � I I ,"__ I .1, � I I I'll'- I , : ::, �
I I
I � I 11 I
I I �
,� I
� � I � I ,. ,�,
I
� I
THE PPROVED PLANS AND SPECIFICATIONS W RMED.. I I I :. �
- .. .
. . I
�A I . I .. .. ...
I � I I
I 11 11 I I I
HOLD-DOWNS. - �
WHERE THE NORMAL PAINEL EDGE NAILING
I I � I 11, I—, 11.1
I I I I I
I I I I ,
: I
I I I I I I
I � :, �:�, �
11 � I
I __ F ;;
I I I ��, :1 1. � �. ,:: :,�::z :, 1, - 11 �: � �,�
I I I
I 11 11 I 11 ... il '':
I I 11 "I'll _�� , I—— I 1 - -, � - - I
I I 11 I 11 11 -
"I'll'',
I - I 11 1-1- 11
,� I 11 � I I .1.1 .11 I I n , I
I 11 I �� , I I - I I I -
11, 1, I � - I I I - ; 11 . I , I I 1, � ;7, �
I � n� I'll, � : I I
I I I �
I I � I : � I
. 1. I— � �
11 . 'I', I : � � � I �
�
: ,.
� I � 11 I � I I
�: I . I
INTERIM,. INSPECTION REPORTS SHALL BE SUBMITTED TOTHE BUILDING �
I I I
� I I I
�
IS MORE THAN 4 INCHES ON CENTER.
, , � � �
I I I
� .11 :
I I I � I
I
I 111 11
, , , , , , , ,
i I
, , � . _ . , -
, I � I - I 111.
- I'll
I I I 1, "I. 11 -
111. . - 11 I I 11 � :n - I ''I'll I I . . �
;: I, ,:.� �� � ''I'll''
11 � I 11.111. I "I'll, I I - I I ''I'', � ..
I 11 I . I'll, � � � � � 1 1 11 11 � I -
I'll I I I - 11 I .. , ,
I I—. - I I I I - - . � n� _ .1 I.,. - I � I I - I . ..... I
I 11 I I I 11 � � _, - - .. - , '' - I .
I . - '' , , , - -
, - - � , _, - , - , _ � 1 I ', 1, 111111-11 11 :,::�,:: .
� , ,..., - , - :,; .11 �. � � , , , , _ , '' , - "'' - . .
I I I I ��
� I.".. I �
I I:- � � - � _,
I I I
I 11 I �
� I I I �. . ,
� I
� . �
I .1 I
. � , ,
, , , F r: , ,
- .
I �
�
� �
DEPARTMENT AND TO HOHBACH-LEWIN, INC. IN ACCORDANCE WITH IBC SECTION .
� �
. I
� .
-
! 3.INSPECT HIGH -LOAD DIAPHRAGMS: 11 I I
I �
1
I I
I I I 1 _____7
SEE IBC SECTION 1705.5 1
I I I I I I 11
I 11 -
1 1 1 I - . I _
I I I I � I
1 1 1 - I
I � �
I � -
... � I'll, . 11 . I � :111, - 11.11,111, , I
� 11 � I I'll, - 1- I 1.1r, - ,
. �,� � I I .1. -
� I I ��: :: � I � ; : I I �1�1 I I I 11 ---.'I,_-,-', "''I'll
- -, � ��� I I.. 11 11 _� I I � 1�� I I I
I 111.11 .11, - ;, I.: � - I ''I'll'', -
11 1. - ''I'll",
11, . 1 I
"I'll �:� 11.1 1. :�
11
I 11 I I . I I
. 1''..,
: � � 1, .
11 I 1. . I
1704,2A. A. FINAL � REPORT OF SPECIAL INSPECTIONS DOCI IRED - � I
I
I I
HIGH -LOAD DIAPHRAGMS REQUIRING
- -
� . � � � �
I . I I
� I
11 �� _ I ::. 111111,1:1.111� 1: I
- � � I : I I -, --l- . . - I "I'll � - 1,
I � I I � I I 11
� . 11 , I - , �. I
� - � I I - _ - - � I I
�. � .1 � 1; 1, 1: I � 111 I 11 11
I ... I
I I I .
.. I
I . . . I
I
SPECIAL INSP � ECTIONS, TION OF ANY DEFICIENCIES NOTED IN ;
TESTING, AND CORREC .
I
I � �. I
INSPECTION ARE DESIGNED 00 THE
� . I � �
I 11 � � 11 1, I - � �
I . I - �
I .1 I I 11 �
I
11 _ , . � �
�� - .1 I.— , I I , I 1; I... � 111. . 11 I -
� .. � . �� n - .. � ,, � 'I'll , I I I
I � � 11 I .1. .1 -
I I I .. �.. _ I I ;. I n� � - , 11 1, I I—, � . . , 1 :: :..
. . .:.: �� I-, - I 1.11'':
- I .
� � . . I I
.1 1. .- I ,. �
I - I I ...
THE INSPECTIONS SHALL BE SUBMITTED PRIOR TO ISSUANCE OF. A CERTIFICATE OF
I I I - . .1
�
�
� I
I
STRUCTURAL DRAWINGS.
I 1. . � I
I I I I
I 111. I I ; �
I I �
- I . I
I 11 I .. I I I
I I .1 11 I I � I
I.: ... ..
I I �... - I
,� I :: .: ,:..
I - � I I . . ......
I . . - - � I . - . ...
11 .- , � :: : .. :
I .. � �
I � .1 . .1
I �� � I I :::..::
. I - - I .. ;;_ ..: : :
.
111. ...
I . . � � I I I,—
I .1 ..
I I . . . .11
. .
. � . .. I
I . . . ..
11 1. :.. I
11 ..
. I . I . .
. . I I I
USE AND OCCUPANCY. .. - - I I
. I - I
I . . 11 I I I
11
I I I I � I
. I
. - ____ �� 11 I I
-
�
I I
. . � I I
I 11 1. 1, I I I 11 I I
. I I I , , , ,
, - ,
1 :, , "'' , , , '' ,
, . � I .1 I I
I - I I'll, , I I .. .
.
,. , , , 'I'll
. ..... , , I :. "I'll ....
. . . ..., I I'll :11,111, :
.. , I I . - .
I - .1 � 1.
-
I . . .
�. I I . I .
. . .... �
.." ''.. ..
I �
:. ': ,::,z - . .
� .:
I
� 11 I I 1. .
� .. . I I
. I'll � . . 1. I I .
.
UNDERSTANDING THAT THE BUILDING : I
THIS PLAN::HAS BEEN DEVELOPED. WITH THE I I
�
A. VERIFY GRADE AND THICKJNESS OF SHEATHING.
I -
I I � � �
�
P
I , �
I I
I ,
I 11 I
. ,. .... I I :. .. I I
. .
� , , , , I I . I 11 I I'll "I'll I I I'll,
� 11 � I 11,11, I - I 11 �:,
11 I I .1 -
I .11 I I I I . . . . . ,.: .:.:..
I . ..... I . . .. . . . .
I .... . . 11
I - I I I I
I I I I.. 1. .......
I .
� I
... : 11 I "I I .
... -
I , ...'' .
I I ... .
I 11 . .1 I I
11 I ... . � .
... . . .1 I I .1 1.
I I 11 I I . . � �.
11 I
. 11 - .. -I
. : ; :
- I I . _ I.. I I
.1 ..
I I— 1. , ,
� 11 � I I .
� . I I ... �
- � � - 1.
, I I .
I I : I I I
I I I
: I
I 11:
. 11 .
OFFICIAL WILL: 11 I .... I
. .
.
� .1 � �
... �
I
. I I - I , ; ,;; --------- 1
I I . I I I
I I . I I I I I I I I
. I I 11 I .:, .:::.
. I I I I I I .
I . I , - I .. ...:::.::::.
. ..:
I I I . .. . .
, I
........ ,. I � I
, , , , ,, '.... . I I .1
I .11
. I I , I
I I I ..::.:.: I I , I
. . I I I
. ..... .. �
I . . , I I
I :
. ,: ..
I I .. I I
I I . I
. ...
I I 11 ��
.
1. REVIEW AND APPROVE THE QUALIFICATION. OF THE SPECIAL INSPECTORS PERFORMING.:
VERIFY NOMINAL SIZE OF FRAMING MEMBERS
". 1: I
P .
. 11 ,,,,
: .11 . . .1 I I
.1 I
, . . 11 . I . . . . .
I .. .... . . . .. .. ..
. .
I .. ... . . . . ... .
.. .. � I 11 . 2
.... ..... I I.- I ''I'll',", 11.1 . ...
I - I'll � �
. : 1:1 11 "I'll- I
- I - .
I . ... � I ... ...
I . I . .
... , ,.. . ....
: : ''....- I... ...
. �
- �
I ..
THE INSPECTIONS . . ... - �
B .
- �
AT ADJOINING PANEL EDGS.
I .
. .
I .. .
. . .
. . I I
. . . .
. I 11 I
I . .. .
I 1. . . .
. ... 1.11 . . . �: .
. . . .
. � . . . . . .. . . . :
I
. .. ,:.:
.. . "I'll", I I
.. . I I I .:
I.. ... . I � �
. ... .. .. _ I I-- I 1- � . � � � . .....
. :, 111. . I'll-, - I 11 . .� ..... .
I �
...: I . ... I 11 I...... ..
'. "....... I-. ........
� .
� � � . ...:.:: : ... � . ..... .
.......'. . . . .
..... ..
� -
:
. �
�
2. MONITOR SPECIAL INSPECTION ACTIVITIES TO ASSURE COMPLIANCE .WITH � . 1. .
; . . I I
I . .... . 1. . . I
. .1 ... .
.
.
. .
. . �. I ..
11 . . ,
. . . ..
. . ... ...
. ..
. . .
.. . �.
. .... � � ...
.... . . - : ,::::.: . � .
... . ..... .... I ... .
� ... I
... 11: ... : ..... . . . ........... . . I ..
. . . . ............... I 11 I .11 � I...... . �
. . I . . .. .... I.... .. . : . . . ............ ... I . � .. . � I
. . . I .. �
. I....
. . �
I . 1; ��� I
. I I . �
I I � . .1 I
.. I
1. I �
I .
. . I . I
PROJECT:: REQUIREMENTS. I I ,.
. I
. . I ...'... .....
I C, VERIFY: . . .
I
I I
. . , . ..
. I . ..
.
I
. - ...... I I
, . . .. ..::.:::.::.. I . �
. '....... . . ........ .... - I ...... �
.. . . .......... I I .
. .- : . � "I'll I .. �
.. � . . , ....I.. I I , 1, � I I I ...
I . ... ....:.. . ........ 11 I I I ..
I
. I . .
..... .
. .. .
:
I I 1. .. . I
. .. . I
.
3; REVIEW::SUBMITTED INSPECTION REPORTS. . I . . I . . I
. . I . ..
I I .
I .
I .
�: I ____ - .
. I I � .
. .�.
I I I
.. I
. I . -
I �..... ....... ,� I I � I .. . I
I 11 I I I
. . .: � ...n. .. ............ : I ""I'll,
I . .... . : _ . ::.: ..... I I 11 I ..
11 "..... � � : ...... . .. .... I 11 ���, � I 11 I I -
I I I I - I I . I
� :..::::::::.:.. ... 1 ��': �: , -,'"I'll: I I I
I I .. ...
.. . .
I I I
I
. .:.:
. I I .... . . I I
''..
4. .PERFO`RM INSPECTION . . . . . .. I
, I I I I . . .. . I
. I I 1. I . ... I
.1 I I I I I I I I . I
. .11
I I
I 1. NAIL OR STAPLE DIAMETER AND LENGTH.
P
�... �. .
�
1. . .
. I I I... . .
I
I I I
I I
11 I
I I I
I
I 11 ... I ... � ....... � .1 ... ... - .... "I'll .. I I
11 I I ... 11 ... � ... ..- ..... - .. ... ... . ., I � .1 I I——
, ::.==:n .... r�� :.::::::::.::. I ''I'll'' I.. ..
11 . :n n .1. ..: '' , , , I .. .
. - 1. ... � ... .. . .. ::::::: : '' , , 1. I
I I . .. . . ..... . :. �: : , , :ZI:', 11 I - � -
- I -
. I I � , I I I ..... ...
. . 11 I . .1 I'll. ....
11 � -
WIND + SEISMIC R I EQUIREMENTS (IBC SECTION 1705,10, 1705.11 :AND � �:: , .
- � ��
I � � � ..
� � _
I - �
I I
� I
I
. ,
..... - -----------I
. -
I I
I I I
. � . � I I I I
I I � :..::� . . .......... , ... .1 � - 11 ....."111
I I I :::::,nn nn - ,: �.: � �.............. _ . �
I ,, ,�� , .:;..: I
I - � � � - � ... .:::::: . ''Ill",- I - �: I I �
I I .. .: � .: ,. � � � �� '' I ,�. , � I �
11 HH::::::�i_ ...
. . � �:� � ,
. .. 1. .
1705.12) DESCRIPTION. OF THE SEISMIC OR WIND.LOAD RESISTING � ,:; I � � : -
I I . .. I ., �.. . 1. I
I - - .
.
2. NUMBER OF FASTENER LINES. 1, I
� .
P
I I I . I 1. .
I
I
I I I I ..
I I... :, ::.:_�nn
- I I", 11 . . I ...: :��:: I 11 1- , � _� � I I., -
''"I'll I
I I 1. . 1. � .:.:::: :n� .. ..", . 11 ':1: ::.,::.. -:11- I - I �
.. I - _ �.:.: ....... :� � � - � �
, . ".1 �� � I . � n�_... :.::.::: ::.: �; I .... __ :_ � I
I .,:...., . I I ... .. :. � � I .. ........ ... I..",'"' .1 ...... . . -
. - I . .: � :...,:.:..:=_,� .. :� ��
� I
1. 11 . I 11
- ; . ...
11 � I I �� � _ I - ,
� -
I -
SYSTEM (SLIRS) AND DESIGNATED LATERAL SYSTEMS SUBJECT TO ,. 11,1111" 11 .
. . I I -
I I - .1 . I..
. �
I
I I
. I
- I
I I .1
I I .
� . :1 �
I
I
I � I I . I 11
I I . ...
I
- 1. 1:1
I I I 1:1..
,� .:.:: :::11 - . � �. ... , .
I . .1 . I : 11-1:1 - _ � � - ..
.. .. - � . I ... I ,� - r: ... :...:. � � ,....:: ...... :.. . .. ... :." , � _ � �
.. .: � . ...:.:: `�:� :: ''. z
I I I ".. I � I , .... :_ .... � : :;.: :::: �
I . I - . � .. .. .::... �:�:: .. . ... ........... . , , _:.. 11:::� �
11 ...... .: � ,..., ... I , - . . � � I
- _4 F . .... ........ ..... �.. �. . :,:: I � I
. .1 I .. 1.. I . ..... - . . :::_� . �
I'.,
� ...... �
. _ :� , .. . ,
I I .
I I ... �. -
11 I .
.
I
.
SPECIAL INSPECTION ,IN ACCORDANCE WITH IBC .SECTION 1 705.3� ... � �. 111.11 I I .. .. �
. I
I I � �: .... .... . .
, � .... . ... .... . . .
, , I . . . . .
.1 I
1, - I
3 SPACING BETWEEN .FASTENERS. IN EACH LINE
-
P
.
I
I 11
I I I - :
I � . . I
I
I I :''
I'll .. I.. ,,, ,�. � , q I:.- � ,: � :,_::: . :, .... ..... ..... .. - ...:::.:::: : I I � .....
- I .. I., ... I.... � 1: � :.,.:: ::_ � � . ........ ..::.:..:,..1 I ... ::::. : _��_,. 11:
::: I
1, � "" 11 . I 11� I . .... , I .. .. � � , �: ... .. : ,:::: ::� � - 1'11.....i� �:! � ]��;: ��� �_�.jj: � :!�!,] �i:�:.�,�
. 11 I I I'll, ., I "I'll 11 I I I . � . � � - .�::::�::�::__, 1.
I 11 11 I 11 � 1.11 . � .. I ".." ...
� I I 11.1,11 I 11 - - 11 I .1 ..... . .... ,.,
.. .. ...... �
::::
I � I
: I I
- I
I
.
1704.3.2 & 1704.3.3.. , I - � � � , . . . ...
11 - � . .
, I I � �
I I � � � .
I I � � . . . ..
I � � -
,� 1 �
,
I N OINS. �: I I
. 11 I I
11
I . 1: �
I ��
I I I I
I - � - ,:.: _:rl �: I , � , ''.... .
I I ''I 11, :� - � .. I "I ;; .. - I I :
� I 1. :�_ - I - ; ;. �� :� �� �:�� - _ � : : ., .: I ..
I I 1: _ - :::: :._. I , .1
- , � I I I'll �, - I I
- 11,111, , � o "I'll, � I I , I I..
�: I � ; ;:_ z .1. I I . . I -
- I I 1.
I
.
I 1. -
1:1
-
I . .
. 1.
.- �
THE EXTENT OF THE SEISMIC LOAD RESISTING SYSTEM IS.OEFINED .114 : , I .. .
, � �
,, , �
I I 11 11 11 �
. I ''Ill, I �: I
E CONSTRUCTION DOCUMENTS. : 11 'I'll I I I 11
I I I � I I
I
I _1:. , "..... I I .11 - I I-. -1 - I I
. I I I
.. - -.11-11.. _ I- I I - _ - '
: � CONCRETE CONSTRUCTION PER 0 5 IBC 1705�3
.1 11 11 2 1
I
I I I -
I 1
I
I � I I -,
I � I
I . � � � � I F I
I I � � � � � �
1 � 11 1, I I I : 11
1 1 1 1 � I -
I I � � - 11 11
�
I 11 1:
� - I I I � 1, ''. I 11 ,� 11 � �,::_: ::: - �, 11 I ,, 11 I.. I ,
- . � - � , � 11 11�1� �::, � - � � 11 -1. � � I
I - 1, I . . I I � n � 'I'll - � �
� � I I I I - ;_1 . : :
11 11 I . :111 � �, ;, "I'll -, . . I �
I I . - � nnn �1'1,111,
. 11 I � il 'I'll - I � I 11 I
� � . �,� _;, %_
I �, I - � 1 I .
I I
I -
1. I
I .1
I �
.
� I - I
11 I
I I I I I I
. 11 ,
� 11 - I
� I I I 11 I 11 I
I I � I I I 11.1 I � �
I I I I - I 11 �
�
- ,
TABLE 1705.3 CONCRETE , , ,, I
� I
I I I I
I
I � � I
I I � � � �
. I I I I I � I
, ��, � 11 I
I I .1
I 11 11 I � .. :�_1,1' -
I I I I I'll I I
I 11 - 1 � . . "I'll, 1.
� �. �
. � -
I :, � I I
I I
11 1.
I I I I I I .
I , 1, I , I
� � - I I I I I � 11 ..
I S I I I . . ...... .. ...
. CHEDULE.:OF SPECIAL INSPECTIONS � . ..
I , �� � I I I I � .... .. :...:: .
- I 11 I I I - � � � � ''I'll I I .. .
� � .11
. � ,
-
ITEM
FRED.
I . I
NOTES
11
I I I I
I I �
I 11 I I I . � ��
I I �
I I
I , 11 . - I
I
11
I I 11
__ I �
I 1 _ - . :
11 . I'— � I .
1 :11,71, - 11
I I I 11, , ,ill I .
11 I I I 1, .::� .1 : , . .
I "I'll - ... .11, I .
� -
I -
� 11 . -
I
� I I
�
I . - - �.
I � � - - � - 11 I
I � � 11 . - I , I
� I I .
INSPECTION FREQUENCY I I I I . . .. .......I., .1
I . . . ,
I I � � 1. 1111. I 1. I I I 11, I I
I � I ''I'll I
- I
-
I ..
I i, INSPECTION OF R EINF60CING. STEEL, INCLUDING ,
I I
P
I I , �
SEE ACI 318-14:-96.13.3.3
I � .
I I I I I � 11 I I I I I
I 11
. . � I I - :
; I 11
I � ........1.1", 'IT I ,: I -.
I I . .1 I'll, 11 I 111 1 , 11 �
I I 11 . . 11 11�, - 11 I 1, 11.1,11", I I I I
11 I 11 :111 ::. , I 11
1''....:....'' 11,11,11, I.. I :
: 11 I .:1 :, ... .1,11,111.
11 ... I 11 .
I
� I
�
I
I 11
I . ... ., I'll, I ..:
I I . .. 1. . .. 1. .11,111, , I I I
C - CONTINUOUS INSPECTION . I . I... I I I I I 11 -
I I I . I : . I I
I I
T.
I
I . . I �
I , �
I : I-, I
11 ..... , . . I 11 I
I ; . ...... , "I" I.. ,� : �� I , 1 11 �
I .:.:.: .1 : ... :. :.: � I . � - � -
... I . I .. : . . . �._, , ��
, �.. : I I-, .. .... .
I
I
-
I I I I I
I.. .
� I I I I I .
. . I I I I I I
., I I , -
P -PERIODIC INSPECTION : I . I I I I I I I I
. � . I I'll,
. I . I -
. I I - - 11 ... 1
I I I
- , ,
2. INSPECTION OF REINFORCING STEEL, WELDING
I
-
SEE AWS.DI.4; ACI 318=14:26.13.1.6
I
, , �
� I �
1
I
� .11.11-1
�� . . ....... ,
� I ,:::,;, : . ,
I .11'....
- -
� I -
� ;;;_:., :: . I �
� � I .. � � � -
� � _ I ,:, ,:..:. .. I . �. I
JS
JS
KK
I KK
KK
.
- �
. I 11 I
X - DENOTES INSPECTION THAT IS EITHER ONE-TIME OR AT:A - :
I'', .
_ � I
IN ACCORDANCE WITH _IABLE 1704.3 TEM 5B
SEE TABLE 1704.3 ITEM 5B FOR
� I
� � �.� I 1111-1-1.... I _� I 1
- . 1-11"I".11 ... . .. .. ... �. 1. - , �
N. I I .. . . � �� I
-
.
I 1. .
. .
I .
FREQUENCY DEFINED IN SOME OTHER MANNER I ...
I �
- I
1705.2.2- ITEM 23
REQUIREMENTS.
� � I
. I � I
... - . I I . I I
... �.
I ..: � 11 -
11 .. �
I .. .. 11 .
�2
� . .
.. .
. . I .
.. 1. 11 I -
. I
.N - INSPECTION IS NOT REQUIRED .1 �
. . . ..... . I � ...
. . .
. . .. . .
. . . I . . . .. .
: - .:,
.� 3. INSPECT ANCHOR TO BE PLACED IN CONCRETE
SEE
.
STRUCTURAL DRAWING FOR
�
;
;
I .1 I �
� - 111. . � �
� . . -
� � � .� � �
I � -
� � . , �
.
E
m
. . . .
.1.___1_,...__.,__.._ . . .. .. .......... .. ... - - ____._..___ _______L�� _______ _._._____ - ------ ____.___...:
I . . I I .
PRIOR 10 AND DURING .PLACEMENT OF CONC RETE
EI ON WHERE THIS
i I
. I I �
. . I I I
� . . .. .. .. I I I � � - �
m
0
..
. I 111. .
CONSTRUCTION PER aOI5.:IBC . - :
.
WHERE ALLOWABLE LOADS HAVE BEEN INCREASED
IS
. .
REQUIRED.
1 . 11
I . .. I... . . I .... I I ,.
... I I
.
. . .
. . :
I 11 I ; I �
I I . I
. .1 � -
.1 I I
SECTION 17.05.2.1 � ,1. �
. I I � �
OR WHERE STRENGTH DESIGN IS USED.
--- �����_
. . .
. .
I I
i I I I I I
-
I I 11
I I I I
I I - I
I I I I I
11 11
-
I-
�
.
. . . .
1. :
.. .
ITEM
FREO;
__�_ _1
.
11 11
:, : �NOTES . � 1:
_____1
I
.: 14. INSPECTION OF ANCHOR POST -INSTALLED IN
P
I I..
I I
SEE ACI 1, !
.
- I
I , 11
11 I I I
11 �
-Ij
:
. I I
I
I .
1
I . SPE IAL INSPECTION FOR STRUCTURAL STEEL ,
C
:
I .
SEE IBC SECTION ::. . �
..... .
, HERDED CONCRETE.MEMBERS
-
-
, I I
. I I
318-14:26.7 .
I I 1, -
. I .. .,
. . I I
I I I I I I
.1 - I I
. I
I I I
. .. . . 'I'll, I
I
I � .
I I I I � I I I I
I I I 1, .
I I I I I � I -
11 I - I I
, - I I I I ''I'll
'I,
I I . I
,� I I . I I ; "" 11 1, I'll,
I I I - , I 1 111. � �
�2
0
P
0
�
0
..
1
SHALL 9 IN ACCORDANCE WITH THE QUALITY
I E
.
. �
1705.2.1 . . . I
11 . . .
�
i 5. �E��Fy USE OF REQUIRED MIX DESIGN
P
SEE ACI 318-14:26.4 1 !
I I I I .
I I I I I I
11
. I I I I I
I I I I I I
I I .1 1, . 1 I I I I I I
I - -1 I I I 1
I I 11 I I � . I I I - 11 I I I - 11 I 11 ,�, - I
I I I I . - - 71 1, I �
E5
E
,
z
<
tz
I I
I I I
ASSURANCE INSPECTION REQUIREMENTS OF
I
:
I
.
I I
, : .
�, : .
,
16. AT FRESH COI,fCRETE IS SAMPLED:
SEE ASTM C 172, C 31; i
I I
I I I I I I ,� � 11 _'��,
I . I I
I 1. I I . I .
:.... I . .. ...
I I I �� I ��,
,
::: �: . ..... �� �, �
I 1.111.1,111.111,11''. I - I .. I . .. ... ..... - I I I .. ..: ::: ,, , ,. "..... , , �
I I .. 1-1-1 I I 1. . I ..., ...... -l- , I I I
.1 I....... - . . 1. 11 : . : �:!�� : �]]: N.:]i...:.!..7. I I ::..:::,, I I I I
. .. ... . . ... . . . ....... ... . .. .. 1-1.... I � i �: : ::: 11 �:��::::;::.:::i..::::.. . - -
....... ...... . . ... ...... I I � I ......... .. � . .. . ..... ... .1 .
�
1 � �
�
I AISC 360
1 1
-
I
11 � ::
I
TIME
. I I-AbRiCATE. SPECIMENS FOR STRENGTH TESTS,
C
ACI 318-14:26.12 1 I
1 . . .
� I
I I I I
I I I 1, I
I I I . .
- � . .. . ..
� - I � .
.1
. ... . .. . - � . :_ � I I 1.
. .. .... .- � � �� , :�.! � :�.! _�:::�r: !]!!.�:: � � :,::.::_:: �: : ..:.1 111. . -
.... .... ...... .... � � I.. I I
... . . . � . ...... ...... . . - I . � � �: � . I �
. �� �� � � .... ........ ......- . . � : � �:::., :.. ..: �_
..... . - ... .. .. . . � -.1 11 I �
... 1. I . - � I : �� � 11 � �. - � '... - � . .
.... � . � � . _ � � .
i�:;i!��: � :,; n� _ �
� ........- , �� � , _ � � , � � I ��,f:::;�: ��� _;____
� , � ;:
� 0
.
-
�_
0
0
1
�
�
m
. I
2. MATERIAL VERIFICATIOI� OF HIGH- STRENGTH �
,; I
I � 1: :
I I
11 I 11 ,,
I I
, I
I I
� BOLTS� NUTS, AND WASHERS:
,
� I I ;; �
� I I
I
1 ___ I-
I M SLUMP AND AIR CONTENT TESTS, AND
I
I
11 I I I I . I I
. I �
,��!��,:::, �
- I - I �� I-,
- �
� � � .. � - - � .. ": ''I'll ' I � � � � 1111-
. � . - . . I I � I I I I : ; , _; .... .. �
- . ".. � � I , �� � � 11
: I �
C5
.
F=
z
-
I
11 I I
I � I I
-
I A. IDENTIFICATION MARKINGS TO CONFORM TO
TM MATE RIAL
�
TEMPERATURE OF THE CONCRETE.
I I.,
I .J .
I 1 1
, , 1, , I I I -l-
I I I I 11 I I
� I - I
� I .11
I � - � � I 11
:
� � � � - . . � I I �
� - � � I I - I .::: ,�,: , I ; I
I I � - �� � � � �.. �
� � .
I I I - 11 - - � . � � . .
� � � :::: I I I .
ffi
f5
<
0
1�
0�
9
-
-,
.
1 I
ASTM STANDARD SPECIFIED IN THE APPRO VED
P
SPECIFICATION AND AISC 360
7. INSPECTION OF CONCRETE AND sHOTCRETE
I
I I
� I
� � � I I
I I
11 � � �
I � _:
�
I - I I : �
� I, "Ill 11 I .
� I - n_%
� � ��� � � , I , ,. . I . I
: � 11 I .
� � � I � '11, �
�
.
�
0
z
�
,
�c
.
M
9 ,.
� � I
CONSTRUCTION DOCUMENTS
I I
SECTION A3,3
-,
I I_ -PLACEMENT FOR PROPER APPLICATION I
ACI I ��
1
I I I I %� �� : -
I I I �
I I I � �� � -
, I I I I
� I I I �
� � - ,_, 1. I I 11
� 1, I I I'll 1, 11 I I I
. I 11 I � 11 I .
.. :_ I I - - - :
.
<
<
2
a
175
�
I
OF COMPLIANCE
-_
P
�
� �
,
11 �, �TECHNIQUES.
� I
�
318-14:26.5.2 I -
� �
I ,� I-:
I I � � I I....
1 - I . .
I I . .....
I I I I
. .. I I � -
,; ;; I I , I'll, I
11 . . � I
..... �. I .1
... .. .� . . I ..; . .,
_ I I I I ., :i:�:�::�, �:�:,: .1 ]: � �,:�
.
�
,
0
�
B. MANUFACTURER'S CERTIFICATE
I
_
----
I
5. INSPECTION FOR MAINTENANCE OF PROPER
I 11 I
I � I
. � I . 11
I . 11.111.
I ... . .
. ...
� � . I . .. . .. ....., 1. I ...........
I
: 1:, � , .
I I I . .
..
11-1.1 - 11 11 11 1. . , "
.. . .1 I - I
I .1 ... . I I .1
. .. I . . �,
11.1 � I.. . . �
...... . I 11 I . .
. . . - I I - I 11 : . I i�:!,l :�: �, :!�!: ,�: � � I �
. �. -l-, I'll, I - 1 � I � � 1
0
E
2�
�
z
2� �
R
I I I
SEE SL S QUALITY ASSURA E
SPECIFIED CURING TEMPERATURE AND �
� I
I
I I 11 I
I..... I I � I
- I I 11", : 11 I : ",%,"I'll'. I'll, 1-1, 111-11 I'll
� �. - � I - ..". , , . ; 1 I I
.. ::�!i;;i;:�ci;�:;�!��!:
1
3. INSPECTION OF HIGH -STRENGTH I
I
PLAIN ON THE STRUT. DRA I S
�
TECHNIQUES,
I
318-1 4:26.5.3 1
. I I I
.
I . I .
, :. ., , ..
I . :. -
- � I � 1. . I .. : I ��� � , 1. I I
.... I I . I
. 1''.. , � �� 1 ''. , : �:_K�r: ,:: ''I''. . .
I 1. .. '''... 11 , I
I I � : .. . �jln, I ...: �!;:�;�I: Y�!��:�J�z;�;�1::i!�i:!!! ::�N I
-
I
.
BOLTING , , . . I
. 11, I 1.
. I .111, 11
11, 11
I
-
FOR ADD'L REQUIREMENTS �
9. INSPECTION OF PRESTRESSED CONCRETE:
�
. I
I I
I :::�
. . I . .. ,
I I . . . . I . .:
11 I I .. .. .1 , I I 1. 11,
. . . -l-,
I . ... I I I - I , -
I I I 11 . . I I I I --l-
I I I I I ... I I I I - ""I'll",
11 . I . . I - I I
I I I . . . I I I - 11 I
I � I �� I .... I 11
I � � i �: ;:_ . ;;:�;;:: r:,i, .. ...... 11�11:��:_.
I q, ..
I 11 111. 11 -,
I I I � .11,11, . , 'I., I 1. I'll, .... - .1.1 I'll... , _:_.. : ,,��::,:::� ... ,
I , I'll . I - 11 . � I'll, . ..... - . I I ".. :: - ::::: ,"�_r.:: .. .. .. ,
�� �
1. 11 .- . .. .... ........ ... . .
I I , � 1. I . I 1 - 1. �
I I 1. . � . - . , I ..: .."', .:: I ".." ......... I
, -
- I I . I I :, I .: � .11.11
"".. . . ...
�a
a
�n
�
3
.
E;
.
�
I
A. BEARING TYPE CONNECTIONS
l
TION M2.5
-
A. APPCICATION OF PRESTRESSING FORCES.
C
I
SEE ACI 318-11i:26.10.1 (a): I
I 1. . I .
I - . .
. I I ., . ... . I .
. . � I . I 11 - I 1.
I I I .
I . , I.. . , I
I .... 1. I
.: �
I .
:,
I I : : ,,, ,],,,i,H.. �� ...:: � : : :: : . I
!:., ,.. .,
11 I ,� - . I I .1 . ,. . :., �.: ....: I
� ::::
_ .: ... � ''.: . 11: .....
::�R
N
,
�.
. .
B. SLIP-CRITicAL TYPE CONNECTIONS
11
P
:SEE ..AISC 360 SECTION M2�5
�
I B. GROUTING OF BONDED PtRESTRESSINO TENDONS
-
C
, -
SEE ACI 318-14:26.10.1 (g) � I
I .11 .1 I
11 I I
1. 1.
. I . .
. ..
. .1 �
. .. .
I .. . I I �
� I .
�
� I - � . �. :.. u ....
�
� � � . .1 ... . ...
� � , � � � - 1. :. :�, % �
.
� - � � � ..
� - I .
� � _ % , - � � - . .. !!�� !!!lii:: 1!!11!1!:. :;Ii!!�.:jj�i�:;,��
- �
� � - ; �. ..
. .. �
.
�j
,�
_:
. . "
�
�i
.
's
-
.
,�
.
.
I I .
. ---
.... I
. I
7 IN THE SEISMIC FORCE RESISTING SYSTEM.
.. . .
� ... . .... .1
. . �. I
. 11 . �
. .. . � � � I .... . . -
� I
. I . . I �... I I
.. I
:2
<
I
�
4. MATERIALYERIFICATION OF STRUT. STEEL
. ..:...:
11 � ..: : ..
1.11
., -
.
io,ERECTION OF PRECAST CONCRETE
MFMRFRI;
I P
-
. ... ... . . I
SEE ACI 315-14:26.9
I ,, �
I . . __�
I
. I I . 11
I . . I 11 � I'll
I . I I I � 11 11
. .. - I'll....
..
. . .
. I 1: I I .
. I .
. . . 1. I I
. .. 1.
. .. . . ...
I ...
I 1, 11 I.. 11 . .. . - . I
I - I .
- 11 . . . I .1. I ..
I 11,
I I � . I I
__
1�q
-
-�q
<
.<
-
11
I
__
TO CONFORM
. . 1:
. .
1. � I
I
A. IDENTIFICATION MARKINGS .
I ECIFIED IN THE
I
I I X
,
SEE z ASTM. A6z OR ASTM A I
I
11NERIFICATION OF INLSITLI CONCRETE STRENGTH,
� OF TENDONS IN
I I 11 I
. .
I
I �:
.. . I "I", . I
11 11 11
I .
I I
I I
. . . . 11 I .
. . I I ..
� I I
I I , . .. ,
I . I
I - �
I I
I I I I � I
I I 1. I I
11
I I I
I I I
.
MAINLAND
APPROVED CONSTRUCTION DOCUMENTS
. ., .
568
.
PRIOR TO STRESSING I
I I
. I .
, I I . . I � �
I I
I I I �
I 1.
11 I I
� - � . 1, . I
I -
B. MANUFACTURER'S MILL TEST REPORTS
I
.
I �..
-
SEE ASTM A6�OR ASTM A 568
POSTENSIONED CONCRETE AND PRIOR TO
REMOVAL OF SHORES AND FORMS FROM BEAMS
P
,
SEE ACI . I � .
I . �
318-14:26.11.2
�
. ". � I � . %
11 .
I 11 - I I :� .
. . . . I I -
. I
1 1 1 1, . �
I .
I'll
- I . I--
I I
. I I . . I I
I
, � - , I .
� .� � I
.. 11 . �
. � � I . I
�.... I .1.
- .
� I -
ENGINEERING
__
5. MATERIAL V�R IFICATION OF WELD
I . -
SEE SLRS QUALITY� ASSURANCE
I AND STRUCTURAL SLABS, .
I I
I �
I I - ,...
� � 11 11 .
I _ 11, 1. �
I I I .I... �
� I I , �
� � 11
I , �
� I I..., I � � 1
� � I ,
.
1 �
I FILLER, , ,
I
MATERIALS _ 11
. I �
% I
:
I 11,
PLAN ON THE STRUT. DRAWING :
FOR ADD'L REQUIREMENTS
�
11 I
I I
T FRAMEWORK FOR SHAPE, ,
12,1LISPEC � .
OF CONCRETE
�
I
I I . �
�
I . �
. . I ,:.. �
. . . . . :..
.
I . . :
. I . . . . ....
11 I ..... . . .
I I I I . .. .
. . . . �
. . .
. I I . I
� I � ..
, , � I I I -
- � , I—.
- � � I I -
I 1. 11 I ,.., �
,� - � . 11 � �
� .11 11 I 11 .
.. 11 I ��
. ... , I
... .I", I _ � I.." ...
.'' I'll, 11
� . 11 - I I "I'', I I I
I I... . 11, I .. - :1 , ,1. � . . .
CONSULTANTS
� � I I
I -
I
LOCATION AND DIMENSION
I
I I � I I
318-14:26.11 I I
. .
I I
I I I � �
,�_
I I . . . I 1. I I _ 1111 . .
� � � 11- . .111 ..... � I I .
11 . 1. I 1-1-
, I 111.11
C
A. IDENTIFICATION MARKINGS TO CONFORM
� X
1 AISC 36b: SECTION A3.5.
MEMBERS 13EG1111 FORMED.
-
I � � I 1,
. I 1:
I ,
I I I � - . � 1, .
I �
1, . I 1. - . 11; 11;
I I -1. 11 .. . ..
I . I .
TO AWS DESIGNATION LISTED 11\1 WPS ,
_ I �
1.
-
�SEE 11 I �
I I __
I
1 3. POST- INSTALLED ANCHOR:
. �
I .
I i
I I I 11
� � I I � I
I � I I I ,�
. - I .. .
I I � � �
I � I I . . .....
Suite 206, 8363 128th Street
.
B, MANUF � ACTURER'S CERTIFICATE OF I I
. I I
I I
X I
I . I �
I I I
I .
I I . , I
I
A. ANERIFY DIAMETER AND.,DEPTH OF HOLE TO
I
.
I . �
''I I
� I � I
� � I I
� I I 11
I I
1 1
I I I
11 . I I � �
I I ,
I I I � �:� I
I I
. I I I
I I I
1 1 �
I I I'll, .
, , . . I
11 - ''Ill- . . �
I 11 .11 .
I I I .. . �. .
I I I . .. . � -
I I - .. �
I � - � � I � �
I � � - I
Surrey, B.C. V3W 4G1
Tel: (604) 543 8044
.
. �
COMPLIANCE REQUIRED � .
I , I �
I 11 ___
- -
CONFORM TO DELINES AND
C
�
11 I
� I I I
. �
I . . . � � I I
. I I I I I
- 11 I � � -
I I I . .
I I . .. .. �.. � �
. . .- I I
I - ,
- 1: ''I". 11
F= (604) 543 8104
6. INSPECTION OF WELDING
11 I 11
11 11
SEE.,SLRS (51UALITY ASSURANCE
�
- VALUES SHOWN ON THE STRUCTURAL DRAWING.
-,
I
� ., I I I i
. . . . � � .. . I
. . I I
. . . . I . . .
... . I . I .�
. . . . . ,
. .
, 11 - _
.. , . I I � ..
I . . . ... ........ � -
. .. I .. . . . ........ . . I . .. - 11
, ... .......:...:, � . . � ., �
, � .. , , - ,
I � I
I I
PLAN ON THE STRUT.. DRAWINGS I
FOR REQUIREM , ENTS -
..
.1 B. VERIFY EPDXY OR EXPANSION ANCHOR IS
X
I -
SUBSTIT UTIONS MUST BE ,
- ,
... .. , I
1. , . . , . . . �
I . � I . .. .
I I I 11 1, I I I . . .. I .... ... ...
I 11 � . I I I ....
.. .. .
. ...:..:. : . . .: . I , I , , -
.. 11 I I . � - 1: 11",
I I . ........ ......... . . I � . . I 1. I I
I ......... . ............... � . I'll.
I . .. ... ..
. , . I . -
.1 .1. I I . ... �
PROJECT TITLE
.ADD,L
� -
. � I
I
. THE STRUCTURAL
OF.TYPE INDICATED 0111
SUBMIT ED TO THE E.O.R. FOR I
I I 11
I - I _ I I
, 11 . I ...
I I I I 1, - I : .
. . .. I
I . 11 . .... .
. . .. . .. I I
I I .... I ... ,
... . 1. I .... �
. .1.1'..., ... -
�
A. STRUCTURAL STEEL
I . I ...
� I
� I � I I I
_1
11� DRAWING. �
- __
I I
I
ACCEPTANCE PRIOR TO USE.
.. .
�
I I I I ::
. . I I �.. . - .. I I I
I . I . I I ....
.. I I 11 : . .. I
I I .
11 . I . I � I I. I..
I . I I I 11 111.
.. - ,
1. , -
. .11111 I I _.
I'll, . I I ::,:_.......... �
� � - I
I
1. I I I
I.. . 1 .
SINGLE FAMILY
1. COMPLETE AND PARTIAL.. PENETRATION �
C
:1 _�
SEE AWS D1. I ...
F C. OBSERVE MIXING OF EPDXY AND � � �
.
.
I
�
E CON
� I
I I I I
11 11 11 I ''..
. . . . . . I . . : : ,
. . � . . . . I I 1. . .
. .. . . . I I I ,� 1,
. - I 11
I . I I
I . I
DWELLING
GROOVE WELDS.: . �
. __
. . I
- .. : .
. ---
.. I
I INSTALLATION OF ANCHORS. VERIFY .
.
C .
.
WHERE INSPECTION IS NOT I
. . I
. � I
. I I I
I
I
11 - I
- I
11 1.
I .1.1
15712-72 AVE. WEST,
2, mul_Tl-�PASS FILLET WELDS . .
.0
SEE AWS D1.1. . I I... ,.... .:
__ I ..., : 1 -
,. -
. TonE ,��. EXPANSION ANCHORS�
_ __.__._.._.__ ---- - -------- - -- - -------- ---
I �., ... .- -
11
-------.-.- -
REQUIRED. . ., . .
- - _j -_ - --- - ______ -.- - - -
I I
1.
I 11
.. . .
. . . .
. . .
I . ... . .
I . 1 �
. �
. ...... 1. .. I . .. .... �
� .... .
. .::. I � 1.
EDMONDS, WA, U.S.A.
. .
3, SlNGLE�PASS FILLET WELDS 5/16" 1
C
.
: ��!::i!:��i�� z: ,:::
, SEE AWS DIA. :
.. �:� .....
L
� SOIL L. L
I L R 2015 IBC SECTION 1705.6
S TE .
L L ' L L ' L ' ' L ' L . .. ... ..
TABLE
.
1705.6 SOIL$ . .
. I :_ - .11,
. � .. . . 1.11
11 L . LLL , ,
11 , �
. .. 1, I . : :n. I-,
. - L . . LL
I 11 L I L . L.. L . 1.1,11,
. 1, I LL I LL . LL L" . LLL
.. .... L -
. .... .
I ... I .
I ... 1. .
L I I -
... . L
L ,. . L
..
I I I
.1 4, SINGLE -PASS FILLET W
,
P
. ...".. I
. - ...
"..."I'l
99: 4��
SEE AWS D1.1. .........� � �! ��i��!��L
. I L L ,' LLL
I 14 ....... ..
L,.T.E ;.
FRED
I NOTES I I I I
I L L L L 1.
. LL
I . I L � I L �L� L
I . I .....L" L L �
L I
. . .. LLLL
I I . . L 'L L
.... . .1
I I .
11 .. : . :. I.. �: ::. . 1. . I ...
. ... . ..... : . I I'll.... I .
LLLL. .:..:::.., I I .1
. ... I ... ... . ... L
".. ".
. I
-
5. FLOOR AND L ROOF DECK WELDS
-
::P
, �". I I . L
I L
SEE. AWS O 1. I - I I -
L .
.. L - 7 �
7!
�:L�_:j .�
... I
L : L L-L". I ff I
L�:::. .. I
JLLLL
� �L VERIFY MATERIALS BELOW FOOFINGS ARE
- ,L L.
I
TA
T BLE
INSPECTIONS REQUIRED 114 HIS
I .... . . I L L L LL L L ' L ' . L L L L L L L '
I . I LL LLL LL I LLLL L .... .. L.
L 11 . .. I L L 11 LL L L I L L L �L �:
. � L L � � L-L-1111
I . ... . . . L . . 'L . L . . .L L
. .
... I L . L L I .. I . ..... ..: L L. ,
. . L . .. . ...
. L L L
. .1 I
I I I I ... ...... .... I I I I
�'� I I I LL ....:. L_ 11
""" I I ILL L'.. I ...:': ... L' I
. L . .. .. .. L...: L I .1
I 11 . . ........... ...... L'. ' ' ' : L 1.
I I.. . . . .. I .. ..... . I I
. I .....LLL L ... . , L nL .:":' '.': L L
.....L . .... LLLLLL ...
..... ... LL . ..... . L L L L L L L L L L ... . .... I ...
I STA
M�11'"A'77'�,�,
6. STUDS USED FOR STRUCTURAL DIAPHRAGMS
P
AW;L � :
SEE D1.1. ,
L' .
:. � AM66AT-E TO ACHIEVE THE DESIRED BEARING
p
THE
SHALL BE PERFORMED BY, PROJECT
I
.LL L
.. 11 . . .- I LLL
I L L 'LLL
I . L L LL LL� :L LLLLL
... . . L LL LL .L L
. . L L L 11 L' L L LLLLL
. .. L L L L I L
. . . . I L L L�L�L
I . .. .... .111, L
11 . . . 1:1: "''.., : : L � n L L L L L . , .
I I .... LL
� ...... ... . I .1.. L
I I .: L
1. ....... . ...... L' 11 . �L= :1:_
. .. L:L�L : ::; L L
"5 - ,
- - "
, '�51 Fli��,111,
I,,, ',11��,
I
1 7. WELDED SHEET STEEL IsTs
I
P
.1 . ��::
: ,: I L
I'll, IL L
I
.
! L . L::.:CAPACITY. I
1. I
LL LLL ...... . L I I I
EOTECHNICAL ENONEER.
G I :
I I I I
. . . . . . .. . � L LL L L
. I . LL, I � �_
I L I I 11 11 L �L �L
L I , I I L L L L L L L I
�L L L L
I I . I I . I L . I I 11 I 11 I L I L L � L L L L L
I .1. L L I . L L L L
1. : : ... ::::..::.:: .I � � 11, ,:. . :LLL LL I
. . I - 11 11
: L ..... .: L L L 'L. ... . .
I . ... ... .... ... . - I I "'. .1.
I ...... . I... .." . . I �' L ,�
, 11 I L . , L'LL,_
. I'll, . . I I 1 .
- , ix'
I . I
,(--_, "I' _
� L" L '
-
11
8, STAIR AND RAILING SYSTEMS L_
P
L L I
I I - 11 I
I L 'L L
L
:::�
L
- .1. I - - -_
L . :2. VERIFY EXCAVATIONS ARE
L . EXTELOED TO PROPER
LL
:� DEPTH AND HAVE REACHED PROPER MATERIALS.
P
I I I
L I
I L I
I I
I - I I
LL . . L L .. ...
I L . - ... L .1
I L L L I . L : .:... .
LL L I ' L LLLL L L ' 'L L. "' '.. ..:. , L
L L I . L
. I , I .
L L I . I 1, L .1 ...
I I I .
L L . . .1 , ,
. L L . L L . . . . I I
-, I � .... .. . ........... -.1 11 . .
I L L I L LL � � I I 1. I ..... .. ......... ."..., I., 1
. L L L . .
. . . : .... "I'll, .
LL I . I
L L .'. , "; '� ... .. . � I L .
: . I r. .. . . . .. 11 � -
I L L . I - I I 11 I I 11 I I - - 1. LL .
. I I ''I'll . . L - 11
.111, , , , L I I LL . .11 I 11.1 ...
I I I LL I L - � L L LLLL L 11 - LLLLL L 'L 111.11 I'll
� 4 -_. �,�" .-
... , * . 'L. "I'll, I I
,l - 11.11 ' LLLL
- L
: �'... L
7, INSPECTION OF STEEL FRAME JOINT ,
P
QU ASSURANQE�:,;
LL:
I LL L LL
LL L
I I L
L I I
I I I I I 1.
I I . I I I I I 11 I
I I . I L I
L I I
I 11 I - .1 - I 1. I , ''.. I - I "I
I - I 11 I I
I I I I'll I , I
I I'll L LL L I 11 - I I I I
11 I LL , , , 11 ...
` 41 .- I-L
1, LLLLLL" .1 , , I
. ,� .
DETAILS FOR COMPLIANCE W/ APPROVED . .
L L . . .. . .
L . .. ...
:. : I
. DRAWINGS
L I
L � :;'3.,PERFORM CLASSIFICATION AND TESTING : , I
I L
I I
� I I
L I . . I L L I
I . L L L
I . L I I I . L L
I I I I LL L L�
I I I I � I L I I L LL
: I I I I I I I I I _ I L 11 I I I I I I I L L LL�L IL LL
L I 11 .11 I I L L L L L L LL .
L - 11 - .
L I LL . I—. .
L I - 1111111
, , �','�, , �
, " �
. . . .
I " _�
* "
"'A "
L ..
L . ...
CONSTRUCTION DOCUMENT S L L L . . . ... .
L . I
- -..-----.----..-.-----��-�-�--�-,--,.- - ----- - --- ---------
I .
- '
FOR ADD'I_ REQUIREMENTS I
� -
" '- � -- -------- - .1 ________ -
,
I . . L I
- : ; L LOT. CONTROLLED FILL MATERIALS.
L L L
P
I I
L L L
I I
I I
I I I I . I 1, I
L I I I
I I I .. I . I I I
I .. .1.
. . ......
.. .
I . .. .
11 11 I "I'll ., I
I 1. I'll
I . I'll'-
. I L L LL L �
. .1. 11 IL L, - L L L L L L L L L L .
I I I L L L L L L L
L
�,n .
L .
I
I
I I I I I
I . . I
I I.. I-. I : .. . .
. .. .... . ....... ..
. . . . . .. . . .
I I . . .. . .. . . . .
I . .. . . .
, I I . I I
L
I'll L L .. I
L
4, VERIFY USE OF PROPER -MATERIALS, DENSITIES
L . . . I I
I
L 11 I
I I I
I I I I I
L I . . I
I I I � . I
I . . I I . ,
. . . .1 I 11 I 11 I
I I I I
.. 11.1 I 11 I
i I L . . L . , I � I . .1 , ,
I . I I 'L.
I I I L
11 'L I
. L - I L ''I'll.-
I I-, I
I I I - ''I'll, L L�L�LL 'L
I I I - - 'L LL LLLL
I I 11 , , 11 - - L LL' L
. L I I-, I ,_ I'll L LL L .
L L L ' L L
I ''. L. . .
- 11 ........
LL L .1 .:, �., . .. ..... - I... ,, .
L L L . . I I - L L . I .... -
'L ... L' . L I I L I L L I -
. .. . L L LLL L LL, 111.1
�P 2 OJ9
I'll, VAL-I D U11ITfL SL
I I
LL . I
AND LIFT THICKNESS DURING PLACEMENT A19D ,
, C
L , . L I _1
L L I .
I , I I LLL. . 1.1.1.11.1
. . . . . I I I .
I . . .. I I I I I L -
i L ..... .. . - I I . L..:.. .11.
I LL I . .. .. I I ,;::: I -
L L . I I , I I I . ..: I . .
I . . . I I I .: . I - ,
. .... I L L L L LL L L -
- .. 'LLL I L L L L L L L L L L I
... .... L L L L L L L L L LLLLL L I I
. I.. L L L LL . LL LL
.1 ,... I L . L L L L L L L L I L .1 . .
L
.I _. I . I . L .
CONTENTS
.
COMPACTION OF CONTROLLED FILL. I
.1 I I
I I .
I ... I
L .
.1 ..., I., I I .. I 11.11,1111, .1 I
. . .... - : I ''. -
. . .. I I I ..
.. . I - : .:..... .
I ... . I I . . . .. .... ..... I . .....
I . . .1
... 1: 1 1 I I'll,
. I . I . 11 .. ..... "''
L L'
- . . .. . 'L .
, _1 I I I . .
I I I I I I.. 1.1, I
. ...... L I I I .. .. I
I... ... . L . . L . . I I
. -
''..", 1. I . . � �
""I I I . 11 RESUB
STATEMENT OF SPECIAL
I
ls&!!�
. 1.
5, PRIOR TO PLACEMENT OF CONTROLLED FILL,
. .
. .
, I L I
I .1 I
.
L I . I I I 11 I I I -
I L L ... , I 11 ,
.. '.1 I 11 I ...
L I I I 11
L L L L .1 1. I ". 1.
L I .1. I I
I .
. I . .
. . I - I - I I I
. . 11 I 11 . . � I
... . I I 11 I I - L
I I ..
INSPECTION 1,
L LL:LOBSERVE SUBGRADE AND VERIFY THAT SUET HAS
P
. .
. . L
. . .
I I I
I I . . 11 I I
I I L
L L L LL . I I L � . 11
I I .. 1.11 I
I
L L I I I
. I . . I . I - I,— I .
. I I
. . I 11 I I , I
". I I I I'll., 111. - -, L . .
� � I I � I I'll, ""I'll, 1, I - L MAY 2 8 2019
I I I I I I I'll, 11 I I
- L' I
CONTACT., AB
JRVASION &
-
I
I
..
. I PREPARED PROPERLY. L I
BEEN L .
L L . .
L . I
L L . � 11 ''I'll , I
I - I
L L .L I'll''.
L L L 11 . ... I
I I . .
I I - 11 I LLLLIL. I I
. L' I .. 1. I
L . ..L.L. I ........ BUILDING DEPARTMENT
. . I I
PROJE :CT No. L
I DWG. NO.
I
.
L . I I
. . 1. . , I
.1 I.. I...
I . L .
I I I . .
.1
. I . L . .
. . .
. . .
. .. . .
- .1
. .
1. . -
. . .....
. . . ...
. 1. L LL LL L . .. .... ..
I
L
. .
.. I
I
. . -.1
. .
L' . . .
L ...
I .
. .
I . .
. L ".........
L .
. . . .. ..
I . . I
. . .
. I I
L' .. ,. I
I 1.11 ... I
. L ,
... . 1. I.., L I I CITYOFEDMONDS
L .
I .. I - I I
. .. . . .. . . 1. . ... - L I
.. . .. . . . - L I
. . I L ..
L ... L . .
- LL L . . .... 11.1
I ........'. . .
L I I . . __ ... I
,
UR801 IS1 01 Al.
IL .
I . I
I . . . .
. .
I I . . .
. I .... . .
L.. ... .
L ...
I ..
L - - .. .1
L... .. I 1-1. 1 . .
. I
. .. I I . . I . .. - .1.
. . . . .
. . 11 .
. I 1, .. . .
I I .
11 . I
I I - -
. L'LL, - .1 : .
... .. ..
L L L ....... . .
. .
L . . .
. .
LL . I
. I.....
...
. .
.
.. I I I . 11 I . I
I
. I
. . I
. I
I . I I I
. I
. . . . I I 11
. . . . . I 11 I I
LL - - .. . . - I I I ,.." I
L L L ..... I -
. . .. I L I
. . I , I
.1. I I L
L ... . . I I
I . I . I I
. . . I I "I'll
I .. I - L I . I I I
I I - -l- I I .1111111 I I
., . .1. I I 11 , _ I -
. . . ... . . .. ... ..... ..
..............
. .. .......
. .. ... ... . . .... ...
c .
B D G
A
... ...... . .. ........ .. .... ...... ..... WALL LEGEND
...... ..........
.. ..... . ...
CONCRETE STEM/RETAINING WALL
2".
- ------ ------ - ---- ----- - -----
COLUMN/POST SCHEDULE
__ia�RK
SIZE
Scl
HSS 5"X5"Xl/4"
P28
2-2X6 BUILT-UP POST
P36
3-2X6 BUILT-UP POST
P46
4-2x6 BUILT-UP POST
P56
4-2X6 BUILT-UP POST
P26
3-2X8 BUILT-UP POST
P6
6X6 DFIR#1 POST
pa
8X8 DFIR#1 POST
:A (A.
. . . . . . . . . . .
... .... .. .. .
WALL
LEGEND
. .. . .. .....
SHEAR WALL SCHEDULE
--fill—AMING NOTES.
A) WHERE PANELS ARE APPLIED ON BOTH FACES OF WALL,& NAIL
SPACING IS LESS THAN 6" D.C. ON EITHER SIDE, PANEL JOINTS SHALL BE
OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE
3-INCH OR , THICKER AND NAILING SHALL BE STAGGERED
8) A MINIMUM OF 3/5- EDGE DISTANCE IS REQUIRED FOR THE NAILING AT THE
BOUNDARY AND PANEL EDGE MEMBERS OF THE SHEAR. WALL UNLESS OTHERWISE
NOTED
C) MINIMUM 7" EMBEDMENT IS REQUIRED FOR ANCHOR BOLTS AT
S"EAF? WALL PANEL.,
D) SHEAR. WALL TYPES 12 AND 13 REQUIRE 3" NOMINAL FRAMING
AND STAGGERED COMMON NAILING AT COMMON FRAMING MEMBERS
ATADJACENT PANEL EDGES.
HARK
R
DESC IPTION
(PER 2015, IBC)
SHEAR
(SEISMIC)
SHE
PLATES TO BLKG.
#/FT.
#/FT.,"
NAILING REQ.
9
15/32" STRUCTURAL I PLYWOOD WITH 8d NAILS 0 6- D.C. AT
EDGES & 12" D.C. FIELD W 2x FRA�WG@16" D.C.
280
307
l6d @ 5" ON CENTER OR
A35 0 20" ON CENTER
4%
L I P d AILS p 4: D.C. AT
D Wn 8
W�_
lbDUEZS' &S lh2u C. FIELD W1 2x FRAMING016" D.C.
430
447
16d 0 3-1/2 ON CEN IER
A35 @ 12' ON CENTER
15/,32- STRUCTURAL I eLYWUUL) M I h tId NAVi v 3" D.C. AT
16d 0 3' ON CENTER OR
EDGES & le D.C. FIELD 21 FqlTARlING9I&0_L I 1
550
575
1 A35 0 10" ON CENTER
2L
'1
15/32 SINUINURAL I FLTWOD 7 "T 'E� j 3" D.C. AT
EDGES & 12- D.C.. FIELD W1 3x FRAMING@16' D.C.
665
840
A35 0 7" ON CENTER
1/2' STRUC111RAL I PLYWOOD/OSB WITH 10d NAILS 0 r D.C. AT
EDGES & 12' D.C. FIELD W/ 3x FRAMING016" D.C.
870
1077
A35 a 7" ON CENTER
FLOOR DIAPHRAGM SCHEDULE
JOIST/DRAG STRUT SCHD.
MAX. SPAN
SIMPSON IIIST
HGR. I (U.N.0)
ALOOWABLE
LOADS
MARK
DESCRIPTION
ISHEAR (SEISMIC)
SHEAR (WIND)
J-1 = 11j" DEEP TJI 560 0 121, D.C.
�l
1520
PER TABLE 4.2A/4.2C: 2015 SDPWS
I #/FT.
1
-2 = 111" DEEP TJI 230 0 16" O.C.
_22'-O
--ITS3.56/11.88
17'-9"
ITS2.37/11.88
1190
FLOOR-1
UNBLOCKED W/10d NAILS 0 6-, 6 &
IE AND FIELD RESPF(.TIVFI Y (ALL CASES)
215
1
300
. O.C.
J-3 = 2XlO DFIR#1 0 16
51 —
_011
LB210
915
NOTE USE FLOOR-1 TYP. U.N.0 ON PIANS J-4 = 2-2XlO DFIRol 0 16" O.C.
I'V-0"
THA218-2
2M
COLUMN/POST SCHEDULE
MARK
SIZE
MARK
SIZE
Bel
HSS 5"X5"XI/4'.
P03
3"2X6 CRIPPLES + 1 STUD
P26
2-2X6 BUILT-UP POST
P82
2-V8 CRIPPLES + 1 STUD
P36
3-2X6 BUILT-UP POST
P83
3-2X8 CRIPPLES + I STUD.
P46
4-2X6 BUILT�UP POST
P61
6X6 DFIR#1 POST AS, CRIPPLES + I STUD
P56
5-2X9 BUILT-UP POST
ps
6X6 DFIR#1 POST
28
3-2X8 BUILT-UP POST
ps
8X8 DFIR#1 POST
P38
3-M BUILT-UP POST
P02
2-2X6 CRIPPLES + 1 STUD
c
BEAM/HEADER SCHD-
NAME
SPAN
FEET
SIZE
_1 _9Q9_
B-26
6.25
3-1
Tr -
- -2 G.y
IB
y__Y1411A 81, 1---
B-28
17.5
5-1 18"Xl 2" GLB
B-99
13.25
B-30
, 7,5
3-1 /8",Xl 2!' GLEI
_B_-_31,
-16.25
5-1 "Xll� 1/2" GLB
B-32 ;
24.25
6-3/47XI 5" GLB ,
B-33
16.00
8-3��'X`IT9 1/2" GLB
B-34
9.00
3-1/5"XI ULB
8
B-35
16.50,
79--_36
73-35
BEARING/ SHEARING WALL W/ 2X6 DF#2
WOOD STUDS @ 161- D.C.
NON BEARING STUD WALL
CONCRETE STEM/RETAINING WALL
WALL SCHEDULE
EXTERIOR WALLS
1ST�: 2X6 DF#1 STUDS 0 16" OX.
PARTY WALLS
1ST FLOOR; 2X6 DF#2 STUDS @ 16" O.C.
LOAD BEARING INTERIOR WALLS
1 ST FLOOR: 2X6 DF#1 � STUDS 0 16" D.C.
SINGLE FAMILY
DWELLING
—72 AVE. WEST,
15712
EDMONDS, WA, U.S.A.
STAMP
'A
NAME SPAN SIZE
FEET
H-1 _L3. 0 2-2XlO OF #1
H -2
ID7 UNTIL SL
CONMINTS
RESUB
MAIN FLOOR FRAMING
MAY 2 8 2019
PLAN
CONTACT: AB
ioN 4
REVIS—_7F
BUI-ING DE MENT
PROJECTNO.
�UR801
DWG. NO.
.,Y.,r=T
S2021
SHEAR WALL SCHEDULE
FRAMING NOTES.
A). :WHERE PANELS ARE APPLIED ON BOTH FACES OF wALL:ic NAIL
SPACING IS LESS THAN 6" D.C. ON EITHER SIDE, PANEL JOINTS SHALL BE
OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE
3—INCH OR THICKER AND NAILING SHALL BE STAGGERED
B) A MINIMUM OF 3/8" EDGE DISTANCE IS REQUIRED FOR THE NAILING AT THE
BOUNDARY AND PANEL EDGE MEMBERS OF THE SHEAR WALL UNLESS OTHERWISE NOTED
C) MINIMUM, 7- EMBEDMENT IS REQUIRED FOR ANCHOR BOLTS AT
SHEAR WALL PANEL.
D) SHEAR WALL TYPES 12 AND 13 REQUIRE 3- NOMINAL FRAMING
AND STAGGERED COMMON NAILING AT COMMON FRAMING MEMBERS
AT ADJACENT PANEL EDGES. —
MARK
DESCRIPTION
(PER 2015 IBC)
SHEAR�
(SEISMIC)
SHEAR
(WIND)
PLATES TO BIXG.,
#/FT.
#/FT.
iNAiLiNG REQ.
15/32- STRUCTURAL I PLYWOOD WITH 8d NAILS 0 67C. —AT�
16d 0 5" ON CENTER OR
EDGES & 12" D.C. FIELD W/ 2x G
REF
&AILIL
80
307
A35 0 2V ON CENTER
15/32" STRUCTURA ITH Id
wUUU T UX� A I
16d 0 3-1/2' ON CENTER OR
EDGES & 12" D.C. FIELD W1 2x
430
447
A35 0 12' ON CENTER
'ENUE'S' 'T L `LIWUA, W 8nTlff 6 3' 1.1 AT
16d 0 3' ON CENTER OR
%
& 17'O'ClIELD W4 2x FRAMING016" D.C.
550
575
A35 0 10" ON CENTER
173T—STRUCTUR—ALI PLTWUUL) WIIH 1Ud NAILS (9 3' O.C. AT..:..:.
12
EDGES & 12' D.C. FIELD W/ 3x FRAMING016" O.C.
665
840
A35 0 7" ON CENTER
13
1/2' STRUCTURAL I PLYWOOD/OSB.W1TH 10d NAILS 0 2" D.C. AT
870
107 7
A35 0 7" ON CENTER
EDGES & 12" D.C. FIELD W1 3x FRAMING@16" D.C.
FLOOR DIAPHRAGM SCHEDULE
MARK
DESCRIPTION
ISHE" (MiS"HEAR
(WIND)
PER TABLE 4.2A/4.2C 2015 SDPWS
#/FT.
#/FT.
FLOOR-1
2WSCOX PLYWOOD UNBLOC=ENAIILS 0 6"�r�
�' 2�30 ABT/BOUNDARY, EDGE AND CT VELY (A ASES)
215
300
WALL LEGEND
BEARING/ �SHEARING WALL W/ 2X6
DF#2 WOOD STUDS @ 16" O.C.
NON BEARING STUD WALL
WALL SCHEDULE
EXTERIOR WALL
1ST : 2X6 DF#1 STUDS @ 16" O.C.
PARTY WALL
1ST FLOOR: 2X6 DF#2 STUDS @ 16" O.C.
LOAD BEARING INTERIOR WALL
1ST FLOOR: 2X6 DF#1 STUDS @ 16" O.C.
.......... .. . ..... .
JOIST/DRAG. STRUT SCHD. mAx. SPAN SIMPSON JOIST ALOOWABIX.
. .. ... .. ... -
HdR. (U.N.0)� LOADS
SINGLE FAMILY
... ........
DWELLING
........ .....
J-1 11j' DEEP TJI 560 0 12" O.C,,:z:- 22'-0" ITS3.56/11.88 1520
15712-72 AVE. WEST,
J-2 = 111" DEEP TJI 230 0 16" D.C. 17'-9" ITS2.37/11.88 1190 EDMONDS, WA, U.S.A.
J-3 = 2X10 DFIR#1 0 16" O.C. 51-oll -13210 915
NOTH4 USE FLOOR-1 TYP. U.N.0 ON PLANS
J-4 = 2�=O DFIR#1 0 16" O.C. 14'-0" THA218-2 2245
COLUMN/POST SCHEDULE:
MARK
SIZE
MARK
SIZE
Sol
HSS 5"X5"XI/4"
P63
3-2X6 CRIPPLES + 1 STUD
P26
2-2X6 BUILT-UP POST
P82
2-2X8 CRIPPLES + 1 STUD
P36
3-2X6 BUILT-UP POST
P83
3-2X8 CRIPPLES + 1 STUD
P46
4-2X6 BUILT-UP POST
Pal
6X6 DFIR#1 POST AS CRIPPLES t I STUD
P56
5-2X6 BUILT-UP POST
P6
6X6 DFIR#1 POST
Fas
3-2X8 BUILT-UP POST
pa
8X8 DFIR#1 POST
p3s
3-2X8 BUILT-UP POST
P62
2-2X6 CRIPPLES + 1 STUD
BEAM/HEADER
SCHD.
NAME SPAN SIZE
FEET
H-1 3,0 2-2X10 OF #1
H-2 6.25 3-2
. .... .
.............. ..
.. ... . .... . . .. .... .
R E S
.................. .. ........... .
. . ..... ... I .. .............
. . . ........ . . .. .... MAY 2 8 2019
. .. .... .. .
V
VA L- I b U
NAME
SPAN
IT
FEET
SIZE
I
6�-3/4"X18" GLB
8-12
14.00
5-1/8"X15" GLEI
jB-1
B-13
k26.50
18.75
5-jL11;;RX,12 1/2" 13LB
B-14
14.00
5-,/, 2. GLB
B-15
14.25
1
5-148"Xl 2 GUS
B-16
4.00
GLB
B-17
19.5
3-1/8"M 2- GL8
CONTENTS
UPPER FLOOR FRAMING
PLAN
e-i8
17.75
8�3/4-Xl 2" GLB
8-19
19.00
3-1 8 X12 GLB
17.75
8 -3 4 X12 GLB
B-21
13.00
L14B'—, 2�B
CONTACT: AB
REVISION
16.00
BUILD" (SPAFZTMENT
PROJECT NO. DWG. NO.
B-23 825 3-1 /8"XI 0 1 /2- GLB CITYOFEDMONDS
GLIB
_qZ.�13,0D 5-1/8"X12 UR801 SzW
. .. ....... .. . . . .
. .. . .. . . ......... .....
. . . . . ........... ......
. . ... .. ................
.. . .. .... .
.. . . ......... . . . ... ... . ... ....
.. .. .. .... .. . .. -
SHEAR WALL SCHEDULE
F
A) WHERE PANELS ARE APPLIED ON BOTH FACES OF WALL & NAIL
SPACING is LESS THAN 6" D.C. ON EITHER SIDE, PANEL JOINTS SHALL BE
OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE
3—INCH OR THICi<ER AND NAILING SHALL BE STAGGERED
B) A MINIMUM OF 3/8" EDGE DISTANCE IS REQUIRED FOR THE NAILING AT THE
.:BOUNDARY AND PANEL EDGE MEMBERS OF THE SHEAR WALL UNLESS OTHERWISE NOTED
C) MI I NIMUM 7-.EMBEDMENT.IS REQUIRED FOR ANCHOR BOLTS AT
SHEAR WALL PANEL. I
D) SHEAR WALL I TYPES .12 �AND 13 REQUIRE 3" NOMINAL FRAMING
AND STAGGERED COMMON NAILING AT COMMON FRAMING MEMBERS
AT ADJACENT PANEL -EDGES.
MARK
DESCRIPTION
(PER 2015 IBC)
SHEAR
(SEISMIC)
SHEAR
(WIND)
TO BLKG.
PLATES ,
Z�l
#/FT.
#/FT.
NAILING REQ.
15/32 STR WITH Sd NAILS 0 T—TU. —AT
16d 0 5" ON CENTER OR
9
EDGES 8: 12"O'CRILIELDLYWWO01 11A�N
280
307
A35 0 20" ON CENTER
SIRUCTURAL I FLYWOOU d I I I W7 O.C. AT
TER OR
V " 0
10
1' O.C. FIELD W/ 2x FRAMING016' D.C.
EbQE'S& 12
447
All P'll l"ElTER'
15/32" STRUCTURAL I PLYWOOD W IH 8d NAILS 0 Y U.C. —AT
l6d 3" ON CENTER OR
11
EDGES & 12, o.c. FIELD w 2x FRAMING016" D.C.
550
575
A3 @ 10" ON CENTER
12
1-5/32- SIRUG[URAL I PLYWk!) VATH 10d NAILS 0 3" D.C. AT
EDGES & 12' D.C. FIELD W1 3x FRAMINGGI 6" O.C.
665
L
840
A35 @ 7" ON CENTER
1
13
1/2" STRUCTURAL I PLYWOOD/OSB WITH 10d NAILS 0 2" D.C. AT
870
I
1077
1 A35 @ 7" ON CENTER
I
EDGES & 12" D.C. FIELD W/ 3x FRAMING016' D.C.
ROOF DIAPHRAGM SCHEDULE
MARK
DESCRIPTION
SHE&R SEISMIC
S EAR WIND
PER TABLE 4.2A/4.2C 2015 SDPWS
#/FT.
#/FT.
11 1;,STIICTIRAL lyll IlEl W/8d NAILS 0 6", 6-
1 '11, AT SO .. AR . EDGE AND FIELD RESPECTIVELY iALL CASESj
215
400
ROOF-2
115�32" STRUCTURAL I BLOCI(ED W/8d NAILS 9 6
0 O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
320
447
NOTEG USE ROOF —I TYP. U.N.0 ON PLANS
COLUMN/POST SCHEDULE
MARK
SIZE
MARK
SIZE
scl
HSS 5"X5"Xl/4"
Po2
2-2X8 CRIPPLES + 1 STUD
P26
2-2X6 BUILT—UP POST
pas
3-2X8 CRIPPLES + 1 STUD
p3o
3-2X6 BUILT—UP POST
Pal
6X6 DFIR#1 POST AS CRIPPLES + 1 STUD
P46
4-2X6 BUILT—UP POST
pe
6X6 DFIR#1 POST
P28
3-2X8 BUILT—UP POST
pe
8X8 D IR#1 POST
I
P38
3-2X8 BUILT—UP POST
P62
2-2X6 CRIPPLES + 1 STUD
pas
3-2X6 CRIPPLES + 1 STUD
BEAM/,HEA,DER SIC HD.
NAME
SPAN
FEET
SIZE
H-1
5.oc)
2-2XlO DF#1
[T--2
_F_oO
3-2X10, DF#1
—5--1
13.5o
3�1/8"Xll GLZ
B-2
181;;
B-3
_27.58
6.
3:1� Xj� 5:;
1'!5 LB
B-4
14.50
3-1/8"X13.5" GLB
B-5
22.00
1-3/4!'Xl4" LVL
8_6
13.75
—1 8' " '
�3N
Ef— _7
_�:_75_
H8"Xll!N5'_' ORO
9-8
1 11.50
3-11/8"X13.5- GLB
�B-9
I 3-11/8"X13.5- GLB
B-10
1 11.75
1 3-1/B_Xl3.b GLIJ
WALL LEGEND:
BEARING/ SHEARING WALL W/ 2X6.
DF#2 WOOD STUDS @ 16" D.C.
2X6 DFIR#1 BEARING STUD WALL
NON BEARING STUD WALL
WALL SCHEDULE
EXTERIOR WALL
1ST : 2X6 DF#1 STUDS @ 16" O.C.
PARTY WALL
IST FLOOR: 2X6 DF#2 STUDS @ 16" O.C.
LOAD BEARING INTERIOR WALL
1ST FLOOR: 2X6 DF#1 STUDS 0 16" O,C.
SINGLE FAMILY
DWELLING
—12 AVE
b/ 12 VVESI,
EDMONDS, WA, U.S.A.
STAMP
............. . .........
...... ........ ..... .
... . . . ....... . .......
. . .... . ....... ..... .... ......
'1 /73
. . . .... . .......... ... . .... . .......
. . ....... .
..... ... ....
BEAM HANGER SCHD.
BEAM MARK
BEAM SIZE
SIMPSON GR.
(IT.N.0)
ALLOWABLE
LOAD
SEE PLAN
1-3/4"X 14"LVI,
HUCQ1.81/9—SDS
2000
JOIST/DRAG STRUT SCHD.
MAX. SPAN
"'PSO" HGR'
(U.N.0)
ALLOWABLE
LOAD
R-1 14'� DEEP TJI 560 0 12"� O.C.
25'—,3"
ITS3.56/14
1520
R-2 14!' DEEP TJl 560 0 16" O.C.
21'-6"
ITS3.56/14
1520
R-3 14," DEEP TJI 230 0 16" 0. C.
17'-1"
ITS2.37/14
1520
RESUB
CONTENTS
ROOF FRAMING PLAN
MAY 2 8 2019
l'UILDiNG DEPARTMENT
CITYOFEDMONDS
CONTACT: AB
REVISION
PROJECT NO.
DWG. NO.
UR8nj 1 �)Zu4j
TABLE A:
BASEMENT WALL ANCHOR BOLT DETAIL
B.0L'ANCHOR
CONNECT SIMPSAN A35 &
h
SPACING
TOE NAILS TO JOISTS
SPACING
B'-O"
R"0016" O.0
CONNECT SIMPSON A35 TO EACH
JOIST/BLOCK + 10d TOE NAILS@3"O.0
(ONLY FOR
TO JOIST AND RIM JOIST/BLOCKING
7'-6"
J"0@24" 0.c
CONNECT SIMPSON A35 TO EACH
JOIST/BLOCK + 10d TOE NAILS@3"0.0
TO JOIST AND RIM JOIST/BLOCKING
71-01,
J"oo3o" o.c
CONNECT SIMPSON A35 TO EACH
JOIST/BLOCK + 10d TOE NAILS04"O.0
To JOIST AND RIM JOIST/BLOCKING
6.-6.1
a"o@,35" o.c
lod TOE NAILS*4"O,C TO JOIST
AND RIM JOIST/BLOCKING
I
h = DIFFERENCE OF FINISHED GRADE LEVEL �AND
BASEMENT FLOOR LEVEL
USE DOUBLE MUD$ILL (2-2XB) TOP PLATES
10. TYP. BASEMENT WALL DETAIL
Tel: (604) 543 8044
Fax: (604) 543 8104
(FLOOR TJ1 PERPENDICULAR TO WALL)
......... ...
#3-30"X30" DOWELS
#3-�30"
REINF. AS
i-DOWELS
PROJECT TITLE
P ER PLANA,,
a 18"0
SINGLE FAMILY
5 @ 12"O.C.
DWELLING
OTTOM
H WAY BOT.
WATERSTOP AROUND
I'
12 D.C. 9 CENTER OF WALL TYR
15712-72 AVE. WEST,
TYPICAL SEE ARCH.
.-DOWELS TO MATCH . ... ... .
EDMONDS, WA, U.S.A.
I EPDXY GROUTED
DWGS FOFF \
I a:
VERTICAL . . .... . .... ... ..
INTO CONCRETE WALL
EC
SP IFICATIONS
oP
... ..... . ...... .. .. ... .
2X4 KEY C/W
.. ....... . ..
\MIN.
.. ............. .
... ...........
-WATERSTOP SEE . ..... .... ..... ...........
... . . . .......
STAMP
8"
CONC. WALL
co 0
ARCH. DWGS FOR ... ....
SPECIFICATIONS
.. .. ....
PLYWOO
. ........ ..
FORMWORK
#5 0 1 6'O.C. C/W 5
R
.. .
.....
........... ..
......
X 2' DOWELS INTO SIDE
1
...... ................
CONCRETE WALLS
#5' 0 12"
O.C'
..... . . . . .. ..... .... .
.... ......
. . . . . .. .. .......................... .. .
#4 0 12" D.C. VERT.
CENTER OF WA L
0
15. SECTION AT ELEVATOR
. ............
... ... ... ..... .. ....... . ......... . . ...... .. .... . .... .... .....
.............. ........ ....... .............................. .. ......... .
0, 17 7
2-5
SHAFT
. . .... .
.. ... . . ....
.............
............................... . ....... ...
..... ... ... . ....... .. ....... .... . ........... .
�0'
CONT.
........... ..................
..... .. .... ........ .... .. ................. .... ... ... . .....
MM 2019
14. TYP. CONCRETE STAIRS DETAI
. .....
... .... .... ....... .. .. .. . .. ... . .. ........ .... ..... .
. ..... ..... .. ....
V114 Tj L 6 ID 2�o t I
. . ....
.... ... .. . .. .
. . ....
. ...................
........... .........
.. ................... I,-, . ". 11 . ....... .
..... ....... ..........
CONTENTS
TVDI(-Al DPTAILS
RESUB
. ... ........ .. . .. ... .. . . ........ MAY 2 8 2019
CONTACT., AB
REVISION
.......... .... ....
.. ..........
. . .... .. ... ........ . BVIUDINQ D1rRTMENT
OF E "N'
PROJECT No.
DWG. NO.
. . ....... .
... . ....... ..
.. . ... ... . ......
UR801
IS301
. ... ...... .. .
... . . .... ... ... . . . ............... ...............
.. ..... ... ........ ........... .....
3/8" THK.X8.5"X18"
STEEL PLATE WELDED
4-TO HSS COLUMN
SIMPSON CS16 STRA
SID ES
/�IE
SIMPSON CS16
STRA P TIE ON BOTFF\
ALUMINUM GUARDRAIL BY
OTHERS, SUBMIT SHOP
. . .. ....
P66F PURL —INS
CONT. HSS
COLUMN
7_
HSS COLUMN--<, 1 4' THICK U PLATE
4
LA /(5) 5/80 MB
PER P N
STEEL BEAM,
SEE PLAN
2-2X1O FILLER
C/W 5/8,10
SENAMBOTH
SIDES OF BEAM
DRAWINGS FOR REVIEW
PER PLAN
BOLTS 0 24"O.C.
-WOOD POST, IF ANY
TUD WALL
ROOF JOIST
WOOD BEAM
2
FLOOR
SIMPSON BC POST CAP\�
NO SHEATHING
SEE PLAN
FLOOR SHEATHING-\
HEITHING
7
1/4" THICK U PLATE
ODD BEAM
FLOOR SHEATHING:�
UNDER POST
SIMPSON OS16,/
\PMPSON A35
SIMP SON A35
-':*\-SIMPSON CS16
STRAP TIE
SLOPE TO DRAIN
A
5/8'.0 MB W
A .0 MB
W/V 5/8' �JE
E
3 EDGE DISTANCE
PER PLAN
P
�4
1 O"X4 'X1/4" PLATE
STRAP TIE
FRAMING ANCHOR
FRAM NG ANCHOR
DECK JOIST RESTING ON DOUBLE PLAT�
FL Go=�
DOUBLE BLOCKING
WOOD BEAM
BEAM
WELDED T 0 BOTTOM
BEAM
��j
BEAM
ETWEEN STUD S
PER, PLAN
FLANGE OF BEAM
00 D POST
00 D POST
0 OD POST
U
\_ LID BLOCKIN
0 o/W
�rF
.Q SHEATHING
R
SECTION A-
SIMPSON CC POST CAP
SIMPSON POST
/SEE PLAN
/SEE PLAN
/43EE PLAN SIMPSON CC POST-/
CAP OR STRAP
\SEAM AS
DECK AND FLOOR JOISTS
I
FOR SIMILAR CONNECTION IN
TIE, SEE PLAN
PER PLAN PLYWOOD/
SH EATHING
-STUD WALL
ROOF, USE 1 /4" THICK U
WOOD POST,
P. T
-WOOD POST
—7
\,POST AS
S
DRAG STRUT
PLATE W/(4) 5/8" MB W
SEE PLAN
PER PLAN
TAS PER PLAN
�1/4" U F� TYP. 3" EDGE DISTANCE AND 2.5",
+4-L
S SM,�O CM T11
IMPSON CMST14
PITCH. :WELDED TO HSS
25. TYP. BEAM TO POST CONNECTION
26. TYP. BEAM TO POST CONNECTION WITH STRAP TIES
27. TYP. DECK FRAMING DE TAI
E 4
STRAP TIE x 48"
Sj��p IT x IS
. .. ... .. .... .....
42. TYP. STEEL BEAM TO WOOD
WITH
POST CAP
LONG
. .....
POST CONNECTION
TUD WALL
35. WOOD BEAM TO STEE
.......... .
COLUMN CONN.
MAX. OPENING 8 -0
HEADE ROOF OR
R OR
FRAMING., ABOVE 16d NAILS 0 8" D.C.
SIMPSON A35
FRAMING ANCHORS
SIPSON ST18 STRAP
TIE
3-2X6 CRIPPLES
1 END STUD_-,,,�
SIMPS A
ANCHORS
r
C�
2X8 BU C
///'FRAMING
r@ 12" .0
1%I CONT. 2-2X6 PLATES
IMPSON A35 Bd NAILS 0 6" D.C..
FRAMING ANCHORS MIN. (3) 16d NAILS
CLINCHED OTHER EN 2XS BLOCKS 0 12" D.C.
SPAN
EDGE STRINGERS
MIDDLE STRINGERS
-L'
OUT FROM 2X12
CU FROM 2X12
< 8'
AVD 1-2X4
DOLE STRINGER
EACH EDGE
NOT REQUIRED
—
>8'<10'
ADD 1-2X6 ON
ADD 1-2X5 TO
EACH EDGE
MIDDLE STRINGER
>10'<12'
ADD 1-2X6 ON
ADD 2-2X6 TO
EACH EDGE
M111111 P qTPIWr.PR
28. TYP. FLOOR 10 MID —WALL CONNECTION
L-ANDING
PLATES
J"o ANCHOR BOLTS
1/2
:y2-24
2-2XIO TYP. U/N (DO NOT
CARRYING
SEE TABLE A
ppj�BCONC.
To 11
L
HANG FROM PLYWOOD)
BEAM
.
3" TOE NAILS 0 4' 0 ' 0
SIMPSON LSSU210 HANGER
2-2MI PLATES
FLOOR JOIST
W/ SLOPED SEAT TYP. U/N
1/2" PLYWOOD SHEATHING 2X4 BLOCKING BETWEEN STUDS -MAX WIDTH 3'-6" S . MPSON LSSU210
HANGER U/N JOIST SPACING NOT TO
2X6 STUDS 0 12" D.C.. SPAN -L' (MAX. I ' - EDGE rACE EDGE rACE E6GE F�CE EXCEED 16"0.0 FOR
P, Sd NAILS @ 4" D.C. I I I __ . - - I- ----I 7�A 2-2X 2-2X6 3=W CONC. BI LATERAL SUPPORT
CONTINUOUS BEAM HUNG SEE DEATAIL
BEAM AS ONTACT ENGINEER IF SPANI ONTO END OF CARRY NG
V IS LONGER THAN 12'-,.,
FLOOR JOIST �\_1/2" PLYWOOD SHEATHING . .. . .... PER PLAN BEAM BY INVERTED HANGER INVERTED H
ANGER,
SEE PLAN FOR
SECTION A -
REQUIRED CAPACITY
CONNECT STUD TO CONNECT STUD TO 30. NTYP. INTERIOR STAIR STRINGERS DETAIL 44. FLOOR DIAPHRAGM TO CONIC.
TOP AND BOTTOM TOP AND BOTTOM BEAM CONNECTION DETAIL AT DECK.
-7
PLATES N MPSON T f
Ai6 ANCHOR 2 ROWS OF 10d 2 ROWS OF 10 A35 ANCkRS
SIMPSON A35 NAILS B" D.C. NAILS @ S" 0.
G ANCHORS
+ �KEI MIN, i" p 0 \MIN. J" PLYWOOD
FLOOR
�TU 5 FRAMIN
12 LAP IINT L LAP INTO WALL
SPAN
EDGE STRINGERS
MIDD E S R G
V
CUT FROM 2XI2
CUT FROM 2X12
< 7'
ADD 1-2X4 ON
MIDDLE STRINGER
EACH EDGE
NOT REQUIRED
>7'<9'
AFD —1-2X6 ON
-AD-D 1-2X6 TO
EACH EDGE
MIDDLE STRINGER
ADD I-2X6 ON
ADD 2-2X6 TO
EACH EDGE
M.IDDUE STRINGER
31g, TYPICAL INVERTED HANGER DETAI
LANDING
JTJ
10 TYP U/N (DO NOT EDGE FACE EDGE FACE EDGE FACE
HANG FROM PLYWOOD) 3-2X 4-2X 4-2X
\SIMPSON LSSU210 HANGER 36. TYP. NAILING PATTERN FOR BUILT—UP POSTS
CONT. 2X4 BLOCKING L -MAX WIDTH S-6" W/ SLOPED SEAT TYP. U/N
2-2X6 BETWEEN A
PLATES STUDS SIMPSON LSSU210 2j" gX- NAILER C/W 1/2-0 BOLTS
NAILS @ 4"O.C,
�ALL MATERIAL SHOULD
PLAN VIE SPAN 'L' (MAX. 11' ANGER A STAGGERE S a 18" D.C. STAGGERED
U/N D IN TWO ROW
JS
JS
KK
KK
KK
_�P.
_D]
ELEVATIO 29. ]_�P. BAY WINDOW DETAIL ... .. .. BEAM AS FLOOR SHEATHING FACE MOUNTED JOIST HANGER;
.
[AS PER MANUFACTURER
PER PLAN NTACT ENGINEER IF J�P�0�1
'I IS LONGER THAN
31. TYP. EXTERIOR STAIR STRINGERS DETAIL FLOOR JOIST IST
FLOOR JO
SIMPSON H2.5 TIE
/DOWN a EACH TRUSS"\
36" FROM EDGE 36" FROM EDGE
WOOD JOISTS 2-2X- STUDS 2X- STUD WALL F A , BE�l �2 1 DRAG BEAM WOOD FILLER t,14 EACH \-STEEL BEAM
STEEL AS PER PLAN SIDE OF STEE
COLUMN 7 3 ROWS VERTICAL DUCT THROUGH
IN LS BE BOLTED
z
<
!7
ES IFLOOR JOIST 0 3" O.0 IN. 10� STUDSW ALL, SEE MECH DWGS W/ 1/2"0 BOLTS 0 24" O.C. STAGGERED
NAILS PE OW) FOR I ZEIAND LOCATION
�7
S2
SIMPSON
A35
HEADER
2-2X PLAT!j",,�'
SIMPSO
SIMPSON S IS STRAP TIEY.
MAX._OPENING_8'=O!
IWINDOW OPENING]
. 6,2-2X8 PLATES
SIMPSO
2-2XS PLATES
I WINDOW OPENING]
2-2X8 PLATES
SIMPSON
DOUBLE -WOOD BEAM
STUDS PER PLAN
/-'MAX 0 7'-0" O.0
I
X
A35-j
A35
4 38. TYP. STEEL BEAM TO FLOOR JOIST SECTION
2 ROWS OF SIMPSON S;DS LOOR JC IST AS MA� �,_PDOUBLE TOP WO STS PARALLEL TO BEAM
h"00Y WOOD SCREWS 0 7PER Pl_t 12' CONSULTANTS
2__ 2' LATES
4" D.C. STAGGERED EXISTING BLOCKING -STUD WALL AS CORPORATION
NEW Y�' STEEL PLATE SCAB OVER SHEAR WALL PER PLAN
TO EXISTING DOUBLE TOP .......... . Suite 206, 8363 128th Street
PLATES (SEE SIDE MEW FOR —SHEAR WALL AS ADD EXTRA 2x- STUDS
PER PLAN AT EDGE OF EACH SIDE Surrey, B.C. V3W 4G1
BEAM SEE PLA LENGTH OF STEEL PLATE) OF DISCONTINUOUS WALL und'Lln - A PLIES 0 Tel: (604) 543 8044
-8- 6 AL LUMM INEERE
SIDE VIEW NAILED W/ 3 STAGGERED ROWS NAILED W/ 3 STAGGERED ROWS OF Fax: (604) 543 8104
39. WOOD BEAM SECTION
OF Bd NAILS 0 12" D.C. 16d NAILS @ 12" O.C. EACH SIDE
THK.X8.�"XIB" 34 TYP. REPAIR DETAIL FOR DISCONTINUOUS RIM JOIST AND
STEEL PLANE WELDED
PROJECT TITLE
3/8" THK.X7"XI5.5" TO HSS COLUMN. TOP PLATES AT N RIO NO -XTERIOR SHEAR WALLS
STEEL PLATE WELD*ED T
1/4' TO HSS COLON /4' 1/4" THICK U PLATE
W/(5) 5/8"0 MB BLOCKING L
� I SINGLE FAMILY
SHEATHING PER PLAN vl� DWELLING
PER PLAN MAX 0 7*-0" O.0 IL 2� L
WOOD BEAM
M
\YOOD BEA 7 1 .4,
PER PLAN �,-WOOD BEAM 15712-72 AVE. WEST,
PER PLAN 1 7` 1j" 7" 1�'
EDMONDS, WA, U.S.A.
THICK U PLATE ......... ..
/B�- \ I 1. . . : LAMIX6=12LIE� GO (PSL+LVL)
ME
1; �,; .. I : : ::;_:1;::, � BOLTED W/ 2 STAGGERED ROWS OF 1/2"0 BOLTS 0 12" O.C.
DOUBLE BOTTOM PLATES C WOOD BEAM
THICK U PLATE CINT 1/4 W/(4) 5/8"0 ME
4) 1/2"0 MG 'OL MN PER PLAN ... . .. ....
P
1 4" THICK U PLATE FhQIE, STAMP
'FFR Tn MANI IFrAr.TIIRFrp1q r1jinpq vn
1/4"
PP
ROD SIZE
LENGTH
le
BEARING
PLATE
MODEL NO!
& NUMBER
(in)
(in)
ALL SMF COLUMNS
MFSL-18-6—KT
4
18
1 2Y2
X X
7)/,
4
BEAM
ENGINEERED TO PROVIDE A COMPLETE ANCHORAGE �XB NAILER TOP NAILER a 18eam Topj
SOLUTION MEETING THE 2009 AND 2012, : 1) 1
114TERNATIONAL BUILDING CODE REQUIREMENTS FOR 7 GENERAL:
BOTH TENSION AND SHEAR. 1. SIMPSON STRONG —TIE! STRONG FRAME� AND THE YIEUD—LINKI.:STRUCTURAL FUSEARE, PROTECTED UNDER US PATENT
NUMBER 8.001,734 62 AND MUST BE SUPPLIED OR LICENSED.THROUGH SIMPSON STRONG —TIE.
E MF�,TPL TEMPLATE ARE
W V "SIMPSON s oTIG 1
2. STRONG FRAME SPECIAL MOMENT FRAME IS MANUFACTURED: AND J EMAPK
ED TR — IF
ANCHOR RODS AND TH I
COLUMN Dc Wc Column
ID (I n) (in) Nailer(s)
W 1205 1 2Y2 1512 (1)2x8
I
COLUMN �(Ili A Bbp 9 Tbp THOLE
ID �(Irq) (in) I SIZE
WIOX30 lij 4A T� 1 �/4
COLUMN �(Ili A Bbp 9 Tbp THOLE
ID �(Irq) (in) I SIZE
WIOX30 lij 4A T� 1 �/4
e
e
e
e
e
e
e
e
e
e
e
e
0
e
0
e
e
e
e
0
e
e
ENGINEERING
250 01 Ave 5 Ste 200
4D Edmonds, WA 98020
15 Phone: (425) 778-8500
e Fax: (425) 778-5536
e
civil & structural
engineering & planning
DRAINAGE REPORT
Sharma Residence
15712 72nd Ave W
Edmords, WA 98026
COMPLIES WITH APPLICABLE
CITY�TORMWATER CODE
- ��o
Eraite:
CITY COPY
RECEIVED
SEP 2 5 2018 08121118
BUILDING CG Project No.: 18044.20
P LD ooiff- 1/0 (
Table of Contents
Section I — Project Overview
Section 11 — Minimum Requirements
Section III — Off -Site Analysis
Section IV — Permanent Stormwater Control Plan
Section V —Construction Stormwater Pollution Prevention
Section VI —Special Reports and/or Studies
Section VII —Other Permits
Section Vill — Operation and Maintenance Manual
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ENGIN&RING ph, 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Section I — Project Overview
Sharma Residence 18044.20 August 21, 2018
Drainage Report Section 1, Page 1
Section I — Project Overview
Section I Surnma
Overview
Existing Condition
Developed Condition
nupriliplAl
This drainage report has been written for a new single-family residence project, the Sharma Residence,
located at 15712 72 nd Ave W in Edmonds, WA 98026 (TPN: 00513100002411). The parcel is Lot 1 of the
Meadowview Estates short plat (AF# 201612095001) and is 0.52 ac. It is currently undeveloped and is
vegetated with trees. In the developed condition, there will be a 3-story single-family residence
(including the basement level) with associated retaining walls, walkways, a patio, and a driveway. New
and replaced impervious surfaces total 6,807 sf and the amount of land disturbance is 15,799 sf.
The project must comply with ECDC 18.30 — Stormwater Management Code, the 2014 Stormwater
Management Manual of Western Washington (DOE Manual), and the 2017 Edmonds Stormwater
Addendum (Edmonds Stormwater Addendum). It is classified as a Category 2 project per ECDC 18.30 and
must meet Minimum Requirements #1-9 because the amount of Fiew plus replaced impervious surfaces
total over 5,000 sf. This report is based on the steps recommended in Chapter 7 of the Edmonds
Stormwater Addendum.
Existing Condition
The site is currently undeveloped and densely vegetated with trees on the eastern half. The western
portion has been previously graded with the development of the Meadowview Estates short plat. There
is a steep slope across the site from east to west (30% average) with an elevation difference of 46 ft. Per
the geotechnical engineering report, the underlying soils consist of brown, slightly silty, gravelly sand
with organics, loose to medium dense" and becomes dense at the termination of the test pit at 4 ft.
The site is adjacent to 72nd Ave W to the east, an existing single-family residence to the north, and an
access easement to the east and south. Across the access easement are Meadowview Estates short plat
lots, one of which is developed. Utilities are available at the site from the short plat development,
including stormwater. Please see Section III for the off -site analysis.
Developed Condition
A 3-story single-family residence (including the basement level) is proposed in the middle of the site.
Access to the garage will be from the access easement to the south. Retaining walls will be necessary
along all sides of the development due to the steep slopes.
250 4th Avenue South, Suite 200
Ci 4M Edmonds, WA 98020
rENGINiERING ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section 1, Page 2
Utilities are available at the site from the short plat development, including stub outs for water, sewer,
power, and stormwater. The sewer stub is for a sewer pump installation which will not be used, and the
project will install a new gravity side sewer to the manhole within the access easement. Stormwater
travels downstream from the site through conveyance pipes within drainage easements until it enters
the City's IVIS4 within 75 th PI W about 0.1 mi downstream. The site is within the Puget Sound Piped
Watershed. See Section III for the off -site analysis.
On -site stormwater BIVIPs were evaluated for a project that discharges directly to Puget Sound through
the City's IVIS4. All dispersion and infiltration BIVIPs were found to be infeasible. See Section IV for
infeasibility criteria.
The developed site areas are as follows:
Pervious Areas
Undisturbed Vegetation: 4,1.00 sf (0.09 ac)
New Landscaping: 11,699 sf (0.27 ac)
Total: 15,799 sf (0.36 ac)
Impervious Areas
Roof: 2,667 sf (0.06 ac)
Driveway: 1,530 sf (0.04 ac)
WalkwaVs: 2,610 sf (0.06 ac)
Total: 6,807 sf (0.16 ac)
Tota I Lot:
CM I
ENGIN&RING
22,606 sf (0.52 ac)
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section 1, Page 3
-----0- 4M
IENGINCHERING
Rd
SVJ
l5l.t St Sw
it
Lij nds'Guldi
17,�h F� FA9 Meadovid
15712 72nd Reach Pa
Avenue West
%
N Me3do4b,,,4 160th St SW
MEADOWDALE
wsll?'O
lf32n4PJSW
ZE
"Itsw
64h St SW 164th St Sw 164th STSNV
64* Fi sw
r
zi
do'Vdaj�
Rd
If.52h FV SW 165th PI SW
1661h PI SW
Meadowdale
playfields
:E
f.f
Figure 1-1. Vicinity Map (Google Maps).
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20 August 21, 2018
Drainage Report Section 1, Page 4
Figure 1-2. Aerial Photograph (Google Maps).
250 4th Avenue South, Suite 200
CM Edmonds, WA 98020
ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Section H — Minimum
Requirements
Sharma Residence 18044.20 August 21, 2018
Drainage Report Section 11, Page 1
Section 11 — Minimum Requirements
Section 11 Summa
Narrative
The project must comply with ECDC 18.30 — Stormwater Management Code, the 2014 Stormwater
Management Manual of Western Washington (DOE Manual), and the 2017 Edmonds Stormwater
Addendum (Stormwater Addendum). It is classified as a Category 2 project per ECDC 18.30 and must
meet Minimum Requirements #1-9 because the amount of new plus replaced impervious surfaces total
over 5,000 sf.
Minimum Requirement #1: Preparation of Stormwater Site Plans: The stormwater site plan consists of
this report and the civil drawings, and is prepared in accordance with Chapter 3 of Volume I of the DOE
Manual and the requirements in the Edmonds Stormwater Addendum.
Minimum Requirement #2: Construction Stormwater Pollution Prevention Plan (SWPPP): The SWPPP
shall include a narrative and drawings. The SWPPP narrative shall include documentation that addresses
the 13 elements of Construction Stormwater Pollution Prevention. See Section V and the civil drawings.
Minimum Requirement #3: Source Control of Pollution: All known, available and reasonable source
control BMPs are required for all projects approved by the city. All single-family residential projects
shall, at a minimum, incorporate required BIVIPs from SWMMWW Volume IV, S411 — BMPs for
Landscaping and Lawn/Vegetation Management. The Operation & Maintenance Manual found in
Section VII addresses Lawn/Vegetation management.
Minimum Requirement #4: Preservation of Natural Drainage Systems and Outfalls: Natural drainage
patterns shall be maintained, and discharges from the project site shall occur at the natural location, to
the maximum extent practicable. The manner by which runoff is discharged from the project site must
not cause a significant adverse impact to downstream receiving waters and down -gradient properties.
All projects shall submit an off -site qualitative analysis. A qualitative analysis of the upstream and
downstream system entering the site is presented in Section 111. A conveyance capacity calculation for
the downstream system is included in Section IV.
Minimum Requirement #5: On -Site Stormwater Management: The proposed project discharges
directly to Puget Sound through the City's IVIS4. Per ECDC 18.30, it must implement BMP T5.13 Post -
Construction Soil Quality and Depth and evaluate BMPs T5.10A Downspout Full Infiltration Systems,
T5.1013 Downspout Dispersion Systems, T5.10C Perforated Stub -out Connections, T5.11 Concentrated
Flow Dispersion, and T5.12 Sheet Flow Dispersion. On -Site Stormwater BIVIPs were found to be
infeasible for all hard surfaces due to the steep slope. See Section IV.
250 4th Avenue South, Suite 200
0 Edmonds, WA 98020
rEINGINFEEERING ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section 11, Page 2
Minimum Requirement #6: Runoff Treatment: This requirement applies to the new plus replaced hard
surfaces and the converted vegetation areas. The following require construction of stormwater
treatment facilities: i.) Projects in which the total of pol I ution-ge ne rating hard surface (PGHS) is 5,000
square feet or more in a threshold discharge area of the project, or ii.) projects in which the total of
pollution -generating pervious surfaces (PGPS) — not including permeable pavements is 0.75 acres or
more in a threshold discharge area, and from which there will be a surface discharge in a natural or
man-made conveyance system from the site. The project's total amount of PGHS is less than 5,000
square feet and the amount of PGPS is less than 0.75 ac. Runoff treatment is not required.
Minimum Requirement #7: Flow Control: This; requirement applies to projects that discharge
stormwater directly, or indirectly through a conveyance system, into a fresh
waterbody. Flow control is not required for projects that discharge directly to, or indirectly through the
City's MS4 to Puget Sound. The project is within the Puget Sound Piped Watershed and therefore is
exempt from this requirement.
Minimum Requirement #8: Wetlands Protection: This requirement applies only to projects whose
stormwater discharges into a wetland, either directly or indirectly through a conveyance system. This
project site's stormwater does not discharge into a wetland and does not require wetland protection.
Minimum Requirement #9: Operation and Maintenance: An operation and maintenance manual that is
consistent with the provisions in Volume I and Volume V of the SWMMWW is required for proposed
Stormwater Treatment and Flow Control BMPs;/facilities. The party (or parties) responsible for
maintenance and operation shall be identified in the operation and maintenance manual. For private
facilities approved by the City, a copy of the operation and maintenance manual shall be retained on -
site or within reasonable access to the site and shall be transferred with the property to the new owner.
For public facilities, a copy of the operation and maintenance manual shall be retained in the
appropriate department. A log of maintenance activity that indicates what actions were taken shall be
kept and be available for inspection. See Section VIII.
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ENGINEeRING ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section 11, Page 3
Does the project result in 2,000 square feet, or greater, of new plus replaced hard s"ce area?
OR
Does the land disturbing activity total 7,000 square feet or greater?
No
Minimum Requirements No. I through 5 apply Minimum Requirement No. 2 applies
Does the project add.5,000 square. feet or more of new plus replaced hard suTfacn?
OR
Convert O�. 75 acres or more of vegetation to lawn or landscaped areas?
OR
Convert 2-5 acrcs or more of native vegetation to pasture?
is No
Is this a road ri
Does the pmjcct add
5,000 sq uare feet or No
morc of new hard
surfaces?
ly"
All Minimum Requirements
Y'M
apply to the new 2nd replaced Do nmv hard surfaces add 50% or
hard surfaces and con,6Tdcd more to the existing hard surfaces
Vegetation areas. within the project limits?
All Minimum Requirements No No additional
apply to the new hard surfaces
P. I
an converted ve-getation areas- eq '-
I
Figure 11-1 Flow Chart for Determining Requirements for Redevelopment
(Figure 3.1 of the Edmonds Stormwater Addendum)
250 4th Avenue South, Suite 200
4= CM Edmonds, WA 98020
IENGINE-ERING ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Section III —Off-Site Analysis
Sharma Residence 18044.20 August 21, 2018
Drainage Report Section 111, Page 1
Section Ili— Off -Site Analysis
Section III Summa
Task 1 — Define and map the study area
Task 2 — Review a// available information of the study area
Task 3 — Field inspect the area
Task 4 - Describe the drainage system, and itsexisting and predicted problems
Task 1 — Define and map the study area
An initial qualitative analysis shall document potential off -site impacts of stormwaler discharges for
each upstream drainage system entering a Site, and each downstream drainage system leaving a site
according to Section 6.2 of the Edmonds Storrnwater Addendum. Runoff from the site enters the City's
MS4 within one -quarter mile and therefore must evaluate and document downstream conditions up to
and including runoff entry into the City's MS4.
Pul-I
,*0
0
0
1550��,
12
13 11-0
I Y�
5 C,
13 C]
00
a
0
0 -15 di2j I
0
15605
Ile
7
0
0
PROJECT SITE
15�15
0
7 21,
T
PRIVATE CONVEYANCE PIPE
E C NVEYANCE P E
15 5
1 W16
i 5 7; 2,
MS4 CONNECTION
0
0.1 MI
DOWN STREAM
71
13
13
15 7 Vj 15
1�,711
5722
15701
--------- -
j
15719'
15706
15724
__15722
15729
15730
JJ, ML_L�_
VA J'
13
15806
47400
7324
: L
1qQ(1.
. — 1 1, . ". , "
I I ., I
Figure 111-1 Study Area
4M
ENGINEERING
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20 August 21, 2018
Drainage Report Section 111, Page 2
Task 2 — Review q// ovailoble information on the study ore
Existing stormwater improvements were determined from the survey and the City GIS map. There is an
existing stormwater stub -out on the lot that was built as part of the short plat. From the stub -out,
stormwater is directed to a catch basin within the access and utility easement to the west and is routed
in conveyance pipes within storm drainage easements across private properties to, the public storm
main within 7511 PI W about 0.1 mi downstrearn to the west. The public storm system downstream
consists of 12" and 18" CMP conveyance pipes that eventually discharge stormwater to Puget Sound an
additional 0.07 mi downstream. Critical areas were evaluated using the City GIS map and the lot is
classified as an Erosion Hazard Area (15-40%).
Task 3 — Field inspect the study area
A site visit was done on the afternoon of March 14, 2018. The weather was partly cloudy with rain the
previous day. From evaluating surrounding conditions, the site does not appear to take on any
significant upstream flow. There are existing catch basins on 72 nd Ave W upstream of the site. The
following photos show the existing site, the catch basin within the utility easement, and the connection
to the City's IVIS4 within 75th pl W.
Task 4 — Describe the drainoge system, and its existing and predicted problems
Existing stormwater improvements were determined from the survey and the City GIS map. This is
described in Task 2.
The project proposes to route all roof runoff through roof drains to a catch basin west of the proposed
house. The catch basin will then connect to the existing stormwater stub -out onsite. No on -site
stormwater BMPs for hard surfaces were found to be feasible for the project (see Section IV). There did
not appear to be any issues with the existing stormwater system and it is not expected that the project
will create any issues. See Section IV for a conveyance capacity calculation for the downstream system.
250 4th Avenue South, Suite 200
4= CM, Edmonds, WA 98020
ENGINCEERING ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section 111, Page 3
Figure 111-2. Catch basin in 72 nd Ave W looking north.
Figure 111-3. Existing lot with sewer stub -out looking north.
4= .0- 4M
ENGINEERING
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section 111, Page 4
Figure 111-4. Catch basin within utility easement west of lot looking north.
Figure 111-5. Existing on -site vegetation.
4= CM
ENGINCEERING
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section III, Page 5
Figure 111-6. Connection to City's MS4 system in 75th pI W.
ENGINEERING
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Section IV — Permanent
Stormwater Control Plan
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section IV, Page 1
Section IV — Permanent Stormwater Control Plan
Section IV Surnma
Narrative
BMP Feasibility Review
Conveyance Capacity Calculation
WWHM2012 Additional Flow Calculation
AinrrnthIp
The project must meet Minimum Requirement #5: On -Site Stormwater Management. Per ECDC 18.30,
projects that directly discharge to Puget Sound through the City's MS4 must implement BMP T5.13 Post -
Construction Soil Quality and Depth and evaluate BMPs T5.10A Downspout Full Infiltration Systems,
T5.1013 Downspout Dispersion Systems, T5.10C Perforated Stub -out Connections, T5.11 Concentrated
Flow Dispersion, and T5.12 Sheet Flow Dispersion.
Water quality treatment and flow control facilities are not required for this project (see Minimum
Requirements #6 and #7 in Section 11).
The developed site areas are as follows:
Pervious Areas
Undisturbed Vegetation: 4,100 sf (0.09 ac)
New Landscaping: 11,699 sf (0.27 ac)
Total: 15,799 sf (0.36 ac)
Impervious Areas
Roof: 2,667sf (0.06 ac)
Driveway: 1,530 sf (0.04 ac)
WalkwaVs: 2,610sf (0.06 ac)
Tota 1: 6,807 sf (0.16 ac)
TotalLot:
22,606 sf (0.52 ac)
FeasibilitV Review
Per ECDC 18.30, projects that discharges directly to Puget Sound through the City's MS4 must
implement BMP T5.13 Post -Construction Soil Quality and Depth and evaluate BMPs T5.10A Downspout
Full Infiltration Systems, T5.1013 Downspout Dispersion Systems, T5.10C Perforated Stub -out
Connections, T5.11 Concentrated Flow Dispersion, and T5.12 Sheet Flow Dispersion.
250 4th Avenue South, Suite 200
Edmonds, WA 98020
rENGIN&RING ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20 August 21, 2018
Drainage Report Section IV, Page 2
1. BMP T5.13 Post -Construction Soil Quality and Depth: Feasible. All new landscaping will meet the
Post -Construction Soil Quality and Depth in accordance with BMP T5.13 of the DOE Manual.
2. BMP T5.10A Downspout Full Infiltration Systems: Infeasible. A full infiltration system is not
feasible due to the steep slopes across the site (30% average). Infiltration systems may not be
placed on slopes greater than 25%.
3. BIVIP T5.1013 Downspout Dispersion Systems: Infeasible. The vegetated flowpath may not be on
or above slopes greater than 15%.
4. BIVIP T5.10C Perforated Stub -out Connections: Infeasible. The perforated portion of the pipe
may not be placed on or above slopes greater than 20%.
5. BMP T5.11 Concentrated Flow Dispersion: Infeasible. The vegetated flowpath may not be on or
above slopes greater than 20%.
6. T5.12 Sheet Flow Dispersions: Infeasible. The vegetated flowpath may not be on or above
slopes greater than 20%.
ConveVance CapacitV Calculation
The project will add more impervious surfaces than was previously approved in the original short plat
engineering design for Meadowview Estates (P'LN20140015). The short plat allocated 5,700 sf of
impervious surfaces for the subject parcel (Lot 1 of the short plat) whereas this project will be adding
1,107 sf more of impervious surfaces. A capacity analysis is required per the City Engineer to determine
that the downstream conveyance system can handle the runoff from the additional impervious surfaces.
Assuming an additional 0.03 ac (1,306 sf) of impervious surfaces, the project will add 0.026 cfs more
during the 50-year storm than from the original calculations from the short plat drainage report done by
LDC dated March 12, 2014. See the WWHM2012 output below.
The original short plat calculations used the Stormshed program to model the conveyance capacity in
the downstream conveyance pipes. The hydraulic model included the areas from the short plat as well
as from two offsite basins to determine the flows and capacity of the downstream pipes. Figure IV-1 is a
downstream node layout (from page 4-5 of the original report). CB #0 is the point of connection from
the private conveyance to the public MS4 and is located in 75 1h Place W. For the purposes of this
calculation, only the pipes between the project site and the outfall will be analyzed (Pipes EX #0-9).
The original drainage report included a summary table of the downstream pipes on page 4-21 with the
pipe sizes, flows through the pipes, and flow capacity. The table has been updated below in this report
to reflect the impact of the additional impervious surfaces. The additional 0.026 cfs was added to each
flow and the new ratio was calculated. The additional flow has a negligible effect on the capacity of the
pipes (less than 1%). The most constrained pipe is EX #8 located near the outfall, which is at 51%
capacity.
CM 250 4th Avenue South, Suite 200
Edmonds, WA 98020
rENGINCEERING ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section IV, Page 3
Appendix 4-A
Downstream Node Layout
EX (0 $7
excun
WCONS
'tXCO#4
-V
.XCOS)
rXf)
tX CBS? Ovt Ian ID
+
17)
lXfl fX do St
Ix It
Ox off
txCiialt
Figure IV-1 Downstream Node Layout (LDC, 2014)
250 4th Avenue South, Suite 200
Edmonds, WA 98020
,ENGINEERING ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section IV, Page 4
Table IV-1 Downstream Conveyance Capacity Calculation
Reach ID
Area (ac)
Previous
Flow (cfs)
New Flow
(cfs)
Full Q (cfs)
Previous
Full Ratio
New Full
Ratio
Size
EX #7
2.02
0.4347
0.4611
27.2534
0.02
0.02
12" Diam
EX #6
2.02
0.4347
0.4611
5.0521
0.09
0.09
12" Diam
EX #5
2.02
0.4347
10.4611
12.731
0.03
0.04
12" Diam
EX #4
2.02
0.4347
0.4611
25.2306
0.02
0.02
12" Diam
EX #3
2.02
0.4347
0.4611
14.1324
0.03
0.03
12" Diam
EX #2
2.02
0,4347
0.4611
23.8041
0.02
0.02
12" Diam
EX #1
2.02
0.4347
0.4611
5.0521
0.09
0.09
12" Diam
EX #0
16.6
3.8606
3.8870
19.0245
0.20
0.20
12" Diam
EX #8
14.6
3.8606
3.8870
7.5952
0.51
0.51
18" Diam
EX #9
14.6
3.8606
3.8870
33.307
0.12
0.12
18" Diam
250 4th Avenue South, Suite 200
-0- CM Edmonds, WA 98020
ENGINEERING ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section IV, Page 5
WWHM2012 Additional Flow Calculation
WWHM2012
PROJECT REPORT
Project Name: Sharma Residence Capacity Calc 8.13.18
Site Name: Sharma Residence
Site Address: 15712 72nd Ave W
city : Edmonds
Report Date: 8/13/2018
Gage : Everett
Data Start : 1948/10/01
Data End : 2009/09/30
Precip Scale: 0.80
Version Date: 2017/04/14
Version : 4.2.13
Low Flow Threshold for POC 1 : 50 Percent of the 2 Year
High Flow Threshold for POC 1: 50 year
PREDEVELOPED LAND USE
(To find the 50-year peak runoff from an additional 0.03 ac (1,306 sf)
converted from lawn to impervious, Predeveloped Land Use is modeled as Lawn,
A/B, Moderate slope and Mitigated Land Use is modeled as Driveway, Moderate
slope.)
Name : Basin 1
Bypass: No
GroundWater: No
Pervious Land Use acre
A B, Forest, Mod .03
Pervious Total 0.03
Impervious Land Use acre
Impervious Total 0
Basin Total 0.03
Element Flows To:
Surface Interflow
e') 4M
ENGINLEERING
Groundwater
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section IV, Page 6
MITIGATED LAND USE
Name : Basin 1
Bypass: No
GroundWater: No
Pervious Land Use acre
Pervious Total
Impervious Land Use
DRIVEWAYS MOD
Impervious Total
Basin Total
Element Flows To:
Surface
acre
0.03
0.03
0.03
Interflow
ANALYSIS RESULTS
Predeveloped Landuse Totals for POC #1
Total Pervious A-rea:0.03
Total Impervious A-rea:O
Mitigated Landuse Totals for POC #1
Total Pervious A-rea:O
Total Impervious A-rea:0.03
Groundwater
Flow Frequency Return Periods for Predeveloped. POC #1
Return Period
Flow(cfs)
2 year
0.000021
5 year
0.000024
10 year
0.000026
25 year
0.000027
50 year
0.000028
100 year
0.000029
Flow Frequency
Return Periods for Mitigated. POC #1
Return Period
Flow(cfs)
2 year
0.011921
5 year
0.016048
10 year
0.019055
25 year
0.023178
4M
0
ENGINEERING
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ph. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
50 year
100 year
0.026491
0.03002
ADDITIONAL 50-YEAR FLOW:
0.026491 - 0.000028 = 0.02646 CFS
Per1nd and Imp1nd Changes
No changes have been made.
August 21, 2018
Section IV, Page 7
This program and accompanying documentation. are provided 'as -is' without warranty of any kind.
The entire risk regarding the performance and results of this program is assumed by End User.
Clear Creek Solutions Inc. and the governmental licensee or sublicensees disclaim all warranties,
either expressed or implied, including but not limited to implied warranties of program and
accompanying documentation. In no event shall Clear Creek Solutions Inc. be liable for any
damages whatsoever (including without limitation to damages for loss of business profits, loss of
business information, business interruption, and the like) arising out of the use of, or
inability to use this program even if Clear Creek Solutions Inc. or their autborized
representatives have been advised of the possibility of such damages. Software Copyright 0 by
Clear Creek Solutions, Inc. 2005-2018; All Rights Reserved.
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ENGINEERING ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Section V -- Construction
Stormwater Pollution
Prevention
Sharma Residence 18044.20 August 21, 2018
Drainage Report Section V, Page 1
Section V — Construction Stormwater Pollution Prevention
Section V Summar
Narrative
Erosion control details are provided consistent with the Edmonds Stormwater Addendum and the DOE
Manual. Erosion control plan sheets are provided in full size as a part of the civil drawing set.
A Construction SWPPP is not required by the Department of Ecology because the site is under one acre
(the land -disturbing activity threshold which requires the completion of their SWPPP document and
Construction Stormwater General Permit).
The elements for construction pollution prevention are discussed as follows:
Element 1: Mark Clearing Limits
To protect adjacent properties and to reduce the area of soil exposed to construction, the limits of
construction will be clearly marked before land -disturbing activities begin. Clearing limits will be to the
extents of necessary land disturbance for the new building and associated parking area and walkways.
The BMPs relevant to marking the clearing limits that will be applied for this project include:
High Visibility Plastic or Metal Fence (BMP C103)
Element 2: Establish Construction Access
Construction access or activities occurring on unpaved areas shall be minimized, yetwhere necessary,
access points shall be stabilized to minimize the tracking of sediment onto public roads. The existing
entrance to the site may be used as a stabilized construction entrance and expanded to the 15'
minimum as necessary:
Stabilized Construction Entrance (BMP C105)
Element 3: Control Flow Rates
The site is small enough that a silt fence used for Element 4 may be used to control flow rates.
Element 4: Install Sediment Controls
All stormwater runoff from disturbed areas shall pass through an appropriate sediment removal BMP
before leaving the construction site or prior to being discharged. Silt fence will be installed along the
west, north, and south edges of the site and can be seen on the Temporary Erosion Control Plan, C2.1.
Pollution prevention facilities on the erosion control plan must be constructed prior to or in conjunction
with all clearing and grading to ensure that the transport of sediment to surface waters and adjacent
properties is minimized. The specific BMPs to be used for controlling sediment on this project include:
250 4th Avenue South, Suite 200
Edmonds, WA 98020
eNGiNkRING ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
Silt Fence (BMP C233)
Wattles (BMP C235)
Element 5: Stabilize Soils
August 21, 2018
Section V, Page 2
Leave existing ground cover undisturbed to the maximum extent feasible. Exposed and unworked soils
shall be stabilized with the application of effective BMPs to prevent erosion throughout the life of the
project.
Soils must not remain exposed and unworked for more than the time periods set forth below to prevent
erosion:
• During the dry season (May 1 — September 30): 7 days
• During the wet season (October 1 — April 30): 2 days
The specific BMPs for soil stabilization that shall be used on this project include:
Temporary and Permanent Seeding (BMP C120)
Mulching (BMP C121)
Nets and Blankets (BMP C122)
Plastic Covering (BMP C123)
Sodding (BMP C124)
Topsoiling/Composting (BMP C125)
Surface Roughening (BMP C130)
Dust Control (BMP C140)
Element 6: Protect Slopes
The site is mapped as an Erosion Hazard Area by the City due to the steep slopes (30% average). Existing
ground cover should be left undisturbed to the maximum extent feasible. Exposed slopes shall be
stabilized with BMPs found in Element 5. The existing slope on the western half of the site will be
protected from increased flow rates and sedimentation from the BMPs found in Element 4.
Element 7: Protect Drain Inlets
Drain inlets adjacent to the site and those macle operable on -site will be protected from sedimentation.
Stormwater shall not enter the conveyance system without first being filtered or treated to remove
sediment. Inlet protection devices shall be cleaned or removed and replaced when sediment has filled
one-third of the available storage (or as specified by the manufacturer). The specific BMPs to be used for
protecting drain inlets are:
Storm Drain Inlet Protection (BMP C220)
250 4th Avenue South, Suite 200
Edmonds, WA 98020
CENGIN RING ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Sharma Residence 18044.20 August 21, 2018
Drainage Report Section V, Page 3
Element 8: Stabilize Channels and Outlets
Conveyance channels are not located on or in the immediate vicinity of the site.
Element 9: Control Pollutants
Design, install, implement and maintain effective pollution prevention measures to minimize the
discharge of pollutants. The suggested BMPs are:
Concrete Handling (BMP C151)
Sawcutting and Surfacing Pollution Prevention (BMP C152)
Material Delivery, Storage and Containment (BMP C153)
Element 10: Control Dewatering
De -watering is not anticipated.
Element 11: Maintain BMPs
All temporary and permanent erosion and sediment control BMPs shall be maintained and repaired as
needed to ensure continued performance of their intended function.
Element 12: Manage the Project
Phase development projects to the maximum degree practicable and consider seasonal work
limits.
Inspection and monitoring — Inspect, maintain, and repair all BMPs as needed to assure
continued performance of their intended function. Conduct site inspections -and monitoring in
accordance with the Construction Stormwater General Permit or local plan approval authority.
Maintain an Updated Construction SWPPP
- This SWPPP shall be retained on -site or within reasonable access to the site.
The SWPPP shall be modified whenever there is a change in the design, construction,
operation, or maintenance at the construction site that has, or could have, a significant
effect on the discharge of pollutants to waters of the state.
The SWPPP shall be modified if, during inspections or investigations conducted by the
owner/operator, or the applicable local or state regulatory authority, it is determined that
the SWPPP is ineffective in eliminating or significantly minimizing pollutants in stormwater
discharges from the site. The SWPPP shall be modified as necessary to include additional or
modified BMPs designed to correct problems identified. Revisions to the SWPPP shall be
completed within seven (7) days following the inspection.
Element 13: Protect Low Impact Development BMPs
N/A — All infiltration and dispersion BMPs were found to be infeasible.
250 4th Avenue South, Suite 200
Edmonds, WA 98020
1ENCON96RINCi ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Section VI — Special Reports
and/or Studies
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section VI, Page 1
Section V1 — Special Reports and/or Studies
Section VI Summary:
Norrative
The following reports are included in this section:
1. Geotechnical Engineering Study by Geotech Consultants, Inc, dated January,25, 2018.
4M 250 4th Avenue South, Suite 200
0- Edmonds, WA 98020
IENGINC-ERING ph. 425.778.8500 1 f. 42S.778.5536
I www.cgengineering.com
CYEOTIECTI
CONSULTANTS,. INC-
Amit Sharma
1737A Northwest 60th Street
Seattle, Washington 98107
via email.- amit.sharma@docusign.com
Subject: Geotechnical Engineering Study
Proposed Single -Family Residence
15712 — 72nd Avenue West
Edmonds, Washington
2401 10th Ave E
SeaWc�,Washitigton 98101
(425) 747-5618
January 25, 2018
JN 18021
Our firm has prepared a geotechnical engineering study for the proposed Meadowview Estates
short -plat project dated October 9, 2013. The proposed single-family residence that is under
consideration in this report is on a lot located in the northeastern corner of the short -plat. This
report relies on the information contained in the study for the short -plat property, and provides
geotechnical engineering design parameters for the new residence proposed on the subject lot.
We understand that a residence is proposed in the upper, eastern portion of the site, adjacent to
the west side of 72nd Avenue West. The lot slopes gently to moderately down to the west from the
street. It appears that the residence will have a main level near the street grade, and a basement
level that daylights to the west. We understand that some retaining walls are proposed on the lot
outside of the residence, likely on the more western, downslope portion.
If the scope of the project changes from, what we have described above, we should be provided
with revised plans in order to determine if modifications to the recommendations and conclusions of
this report are warranted.
S/TE CONDITIONS
SURFACE
The Vicinity Map, Plate 1, illustrates the general location of the site in the Meadowdale area of
Edmonds. The subject lot is adjacent to -the western, downslope edge of 72nd Avenue West. The
site is mostly undeveloped, forested, and slopes gently to moderately downward to the
west/southwest. However, an approximate 50 percent slope was graded 'On the western edge of
the lot in the last few years in order to install a street within the Meadowdale Estates short -plat
property; the paved street is now located at the base of this graded slope. This slope is covered
with grass. We made a recent site visit, and we did not observe any indications of instability of the
graded slope of natural slopes on the site.
el Per ECDC 23.80.020A based on soil conditions, any slope on the site that is greater than 15
e percent is considered an Erosion Hazard Area. There are several areas that are steeper than 15
percent on the site. The only area on the site that is greater than 40 percent is on the western edge
e where the street excavation was made as noted above. However, per ECDC 23.80.020.13, these
slope is considered to be a Landslide Hazard Area.
GEOTIECH CONSULTANTS, INC.
Sharma
January 25, 2018
SUBSURFACE
JN 18021
Page 2
Several test pits and test borings were done on throughout the short -plat property in prior to our
2013 study. Two test pits were excavated on the subject lot, while a thir�d test pit was just to the
west. In addition, a test boring was just southwest of the lot. The approximate locations of these
explorations, which were known as Test Pits 5, 6, and 7, and Test Boring 3, are shown on the Site
Exploration Plan, Plate 1. The logs of these previous test pits and boring are attached to this report.
The soil revealed in the upper portion of, these explorations is native sand, with the first 2 to 3 feet
being loose to medium -dense. Then the Sand became dense —which was revealed to the bottom of
the test pit of approximately 5 feet. In the nearby test boring, this dense sand was underlain at
approximately 8 feet by medium -dense silty sand. At a depth of approximately 24 feet, again dense
sand was revealed. The test boring was drilled to a maximum explored depth of approximately 26.5
feet.
The stratification lines on the logs represent the approximate boundaries between soil types at the
exploration locations. The actual transition between soil types may be gradual, and subsurface
conditions can vary between exploration locations. The logs provide specific subsurface information
only at the locations tested, Where If a transition in soil type occurred between samples in the
borings, the depth of the transition was interpreted. The relative densities and moisture descriptions
indicated on the test pit and boring logs are interpretive descriptions based on the conditions
observed during excavation and drilling.
CONCLUSIONS AND RECOMMENDATIONS
GENERAL
THIS SECTION CONTAINS A SUMMARY OF OUR STUDY AND FINDINGS FOR THE
PURPOSES OF A GENERAL OVERVIEW ONLY MORE SPECIFIC RECOMMENDATIONS AND
CONCLUSIONS ARE CONTAINED IN THE REMAINDER OF THIS REPORT. ANY PARTY
RELYING ON THIS REPORT SHOULD READ THE ENTIRE DOCUMENT.
Several test pits and borings were conducted on the short -plat property as noted in our 2013 study,
with several on or near the subject lot. These explorations encountered dense sand soils at shallow
depths. These soils are very competent for supporting building loads, and thus conventional
footings that bear on this competent soil can be used as the foundation of the new residence.
These soils also have high shear strength against slope instability. We understand that in addition
to the residence, retaining walls are proposed on the site in order to provide some level areas on
the site. The onsite sand soils are also very suitable to support the new retaining walls.
Based on ECDC 23.80.070.A.2, "buffer requirements shall be ... consistent with recommendations
provided in the geotechnical report to elirninate or minimize the risk of property damage, death, or
injury resulting from landslides caused in whole or part by activities within the buffer area, based
upon review of and concurrence with a critical areas report prepared by a qualified professional". It
is our professional opinion that no buffers are needed because: 1) most of the site slopes are less
than 30 percent, the western slope that is about 50 percent was graded as part of the Meadowdale
Estates development, and 3) the site soils are very competent at shallow depth.
An "alteration" is needed per Edmonds Code for this project because of the lack of buffers (noted
above) and because development is proposed on Erosion and Landslide Hazard Areas on the site.
GEOTECH CONSULTANTS. INC.
Sharma J N 18021
January 25, 2018 Page 3
Based on ECDC-23.80.060A, an alteration to a Landslide Hazard Area and associated buffer may
occur for activities that:
1 . Will not increase the threat of the geologic hazard to adjacent properties beyond
predevelopment conditions;
2. Will not adversely affect other critical areas;
3. Are designed so that the hazard to the project is eliminated or mitigated to a level equal
to or less that predevelopment conditions; and
4. Are certified as safe as designed and under anticipated conditions by a qualified
engineer licensed in the State of Washington.
In addition, ECDC 23.80.070.A.3 indicates that alterations of a Landslide Hazard Area and
buffer may occur for activities for which a hazards analysis is submitted and certifies that:
1 . The development will not increase surface water discharge or sedimentation to adjacent
properties beyond predevelopment conditions;
2 * The development will not decrease slope stability on adjacent properties; and
3. Such alterations will not adversely impact other critical areas.
It is our professional opinion the alteration is appropriate because all of these criteria] is met,
provided the recommendations in this report are followed and the stormwater from the site is
connected to the stormwater system of Meadowdale Estates (as is planned). We strongly believe
that this development can be done safe and development will be as stable as the current
conditions. It will not affect adjacent properties from a geotechnical engineering standpoint.
As noted earlier, the area on the site are considered Erosion Hazard Areas per the ECDC.
However, we point out that potential erosion hazards on sites such as this only occur only during
construction when the existing vegetation is removed and prior to placing buildings, and
hardscaping and landscaping features. Thus, during construction, erosion control measures are
needed to mitigate the potential for erosion. For this project, we recommend that a silt fence will be
needed around the downslope sides of any cleared areas. Existing ground cover should be left in
place wherever possible to minimize the amount of exposed soil. Rocked staging areas and
construction access roads should be provided to reduce the amount of soil or mud carried off the
property by trucks and equipment. Wherever possible, the access roads should follow the
alignment of planned pavements. Trucks should not be allowed to drive off of the rock -covered
areas. Cut slopes and soil stockpiles should be covered with plastic during wet weather. Following
clearing or rough grading, it may be necessary to mulch or hydroseed bare areas that will not be
immediately covered with landscaping oran impervious surface. On most construction projects, it is
necessary to periodically maintain or modify temporary erosion control measures to address
specific site and weather conditions.
The drainage and/or waterproofing recommendations presented in this report are intended only to
prevent active seepage from flowing thrOLIgh concrete walls or slabs. Even in the absence of active
seepage into and beneath structures, water vapor can migrate through walls, slabs, and floors from
the surrounding soil, and can even be transmitted from slabs and foundation walls due to the
concrete curing process. Water vapor also results from occupant uses, such as cooking and
bathing. Excessive water vapor trapped within structures can result in a variety of undesirable
conditions, including, but not limited to, moisture problems with flooring systems, excessively moist
air within occupied areas, and the growth of molds, fungi, and other biological organisms that may
be harmful to the health of the occupants. The designer or architect must consider the potential
vapor sources and likely occupant uses, and provide sufficient ventilation, either passive or
GEOTECH CONSULTANTS, INC.
e
e
e
e
Sharma JN 18021
January 25, 2018 Page 4
mechanical, to prevent a buildup of excessive water vapor within the planned structure. Geotech
Consultants, Inc. should be allowed to review the 'final development plans to verify that the
recommendations presented in this report are adequately addressed in the design. Such a plan
review would be additional work beyond the current scope of work for this study, and it may include
revisions to our recommendations to accommodate site, development, and geotechnical
constraints that become more evident (luring the review process. We recommend including this
report, in its entirety, in the project contract documents. This report should also be provided to any
future property owners so they will be aware of our findings and recommendations.
Geotech Consultants, Inc. should be allowed to review the final development plans to verify that the
recommendations presented in this report are adequately addressed in the design. Such a plan
review would be additional work beyond the current scope of work for this -study, and it may include
revisions to our recommendations to accommodate site, development, and geotechnical
constraints that become more evident during the review process.
We recommend including this report, in its entirety, in the project contract documents. This report
should also be provided to any future property owners so they will be aware of our findings and
recommendations.
SEISMIC CONSIDERATIONS
in accordance with the International Building Code (IBC), the site class within 100 feet of the
ground surface is best represented by Site Class Type D (Stiff Soil Class). As noted in the USGS
website, the mapped spectral acceleration value for a 0.2 second (S5) and 1.0 second period (SI)
equals 1.33g and 0.52g, respectively.
The site soils are not susceptible to seismic liquefaction during a large earthquake because of their
dense nature and/or the absence of near -surface groundwater.
CONVENTIONAL FOUNDATIONS
The proposed residence and the retaininc
g walls can be supported on conventional continuous and
spread footings bearing on undisturbed, dense, native sand soil or medium -dense silty sand
revealed below the dense sand. We recommend that continuous and individual spread footings
have minimum widths of 16 and 24 inches, respectively. Exterior footings should also be bottomed
at least 18 inches below the lowest adjacent finish ground surface for protection against frost and
erosion. The local building codes should be reviewed to determine if different footing widths or
embedment depths are required. Footing subgrades must be cleaned of loose or disturbed soil
prior to pouring concrete. Depending upon site and equipment constraints, this may require
removing the disturbed soil by hand.
An allowable bearing pressure of 3,000 pounds per square foot (psf) is appropriate for footings
supported on the competent native sand Soils. A one-third increase in this design bearing pressure
may be used when considering short-term wind or seismic loads. For the above design criteria, it is
anticipated that the total post -construction settlement of footings founded on competent native soil
will be about one-half inch, with differential settlements on the order of one-half inch in a distance
of 50 feet along a continuous footing with a uniform load.
GEOTECH CONSULTANTS, INC-
Sharma JN 18021
January 25, 2018 Page 5
Lateral loads due to wind or seismic forces may be resisted by friction between the foundation and
the bearing soil, or by passive earth pressure acting on the vertical, embedded portions of the
foundation. For the latter condition, the foundation must be either poured directly against relatively
level, undisturbed soil or be surrounded by. level, well -compacted fill. We recommend using the
following ultimate values for the foundation's resistance to lateral loading:
ULTEVIATE
VALUE
Coefficient of Friction 0.50
Passive Earth Pressure 300 pcf
Where: pCf is Pounds per Cubic Foot, and Passive Earth
Pressure is computed using the Equivalent Fluid Density.
If the ground in front of a foundation is loose or sloping, the passive earth pressure given above will
not be appropriate. We recommend maintaining a safety factor of at least 1.5 for the foundation's
resistance to lateral loading, when using the above ultimate values.
FOUNDATION AND RETAINING WALLS
Retaining walls backfilled on only one side should be designed to resist the lateral earth pressures
imposed by the soil they retain. The following recommended parameters are for walls that restrain
level backfill:
PARAMEM
Active Earth Pressure
VALUE
35 pcf
Passive Earth Pressure
300 pcf
Coefficient of Friction
0.50
Soil Unit Weight
130 pef
Where: pcf is Pounds per Cubic Foot, and Active and Passive
Earth Pressures are computed using the Equivalent Fluid
Pressures.
* For a restrained wall that cannot deflect at least 0.002 times its
height, a uniform lateral pressure equal to 10 psf times the height
of the wall should be added to the above active equivalent fluid
pressure.
The design values given above do not include the effects of any hydrostatic pressures behind the
walls and assume that no surcharges, such as those caused by slopes, vehicles, or adjacent
foundations will be exerted on the walls. If these conditions exist, those pressures should be added
to the above lateral soil pressures. Where Sloping backfill is desired behind the walls, we will need
to be given the wall dimensions and the slope of the backfill in order to provide the appropriate
design earth pressures. The surcharge due to traffic loads behind a wall can typically be accounted
for by adding a uniform pressure equal to 2 feet multiplied by the above active fluid density. Heavy
construction equipment should not be operated behind retaining and foundation walls within a
distance equal to the height of a wall, unless the walls are designed for the additional lateral
pressures resulting from the equipment. The values given above are to be used to design only
permanent foundation and retaining walls that are to be backfilled, such as conventional walls
GEOTECH CONSULTANTS, INC.
Sharma
January 25, 2018
JN 18021
Page 6
constructed of reinforced concrete or masonry. It is not appropriate to use the above earth
pressures and soil unit weight to back -calculate soil strength parameters for design of other types
of retaining walls, such as soldier pile, reinforced earth, modular or soil nail walls. We can assist
with design of these types of walls, if desired. The passive pressure given is appropriate only for a
shear key poured directly against undisturbed native soil, or for the depth of level, well -compacted
fill placed in front of a retaining or foundation wall. The values for friction and passive resistance
are ultimate values and do not include a safety factor. Restrained wall soil parameters should be
utilized for a distance of 1.5 times the wall height from corners or bends in the walls. This is
intended to reduce the amount of cracking that can occur where a wall is restrained by a corner.
Wall Pressures Due to Seismic Forces
The surcharge wall loads that could be imposed by the design earthquake can be modeled
by adding a uniform lateral pressure to the above-recom mended active pressure. The
recommended surcharge pressure is 8H pounds per square foot (psf), where H is the
design retention height of the wall. Using this increased pressure, the safety factor against
sliding and overturning can be reduced to 1.2 for the seismic analysis.
Retaining Wall Backfill and Waterproofing
Backfill placed behind retaining or foundation walls should be coarse, free -draining
structural fill containing no organics. This backfill should contain no more than 5 percent silt
or clay particles and have no gravel greater than 4 inches in diameter. The percentage of
particles passing the No. 4 sieve should be between 25 and 70 percent If the native sand is
used as backfill, a drainage composite similar to Miradrain 6000 should be placed against
the backfilled retaining walls. The drainage composites should be hydraulically connected to
the foundation drain system. The later section entitled Drainage Considerations should
also be reviewed for recommendations related to subsurface drainage behind foundation
and retaining walls.
The purpose of these backfill requirements is to ensure that the design criteria for a
retaining wall are not exceeded because of a build-up of hydrostatic pressure behind the
wall. Also, subsurface drainage systerns are not intended to handle large volumes of water
from surface runoff. The top 12 to 18 inches of the backfill should consist of a compacted,
relatively impermeable soil or topsoil, or the surface should be paved. The ground surface
must also slope away from backfilled walls to reduce the potential for surface water to
percolate into the backfill. Water percolating through pervious surfaces (pavers, gravel,
permeable pavement, etc.) must also be prevented from flowing toward walls or into the
backfill zone. The compacted subgrade below pervious surfaces and any associated
drainage layer should therefore be sloped away. Alternatively, a membrane and subsurface
collection system could be provided below a pervious surface. It is critical that the wall
backfill be placed in lifts and be properly compacted, in order for the a bove-recom mended
design earth pressures to be appropr�late. The wall design criteria assume that the backfill
will be well -compacted in lifts no thicker than 12 inches. The compaction of backfill near the
walls should be accomplished with hand -operated equipment to prevent the walls from
being overloaded by the higher soil forces that occur during compaction. The section
entitled General Earthwork and Structural Fill contains additional recommendations
regarding the placement and compaction of structural fill behind retaining and foundation
walls.
GEOTECH CONSULTANTS, INC.
Sharma
January 25, 2018
JN 18021
Page 7
The above recommendations are not intended to waterproof below -grade walls, or to
prevent the formation of mold, mildew or fungi in interior spaces. Over time, the
performance of subsurface drainage systems can degrade, subsurface groundwater flow
patterns can change, and utilities can break or develop leaks. Therefore, waterproofing
should be provided where future seepage through the wallsAs not acceptable. This typically
includes limiting cold -joints and wall penetrations and using bentonite panels or membranes
on the outside of the walls. There are a variety of different waterproofing materials and
systems, which should be installed by an experienced contractor familiar with the
anticipated constructi - on and subsurface conditions. Applyinga thin coat of asphalt emulsion
to the outside face of a wall is not considered waterproofing and will only help to reduce
moisture generated from water vapor or capillary action from seeping through the concrete.
As with any project, adequate ventilation of basement and crawl space areas is important to
prevent a buildup of water vapor that is commonly transmitted through concrete walls from
the surrounding soil, even when seepage is not present. This is appropriate even when
waterproofing is applied to the outside of foundation and retaining walls. We recommend
that you contact an experienced envelope consultant if detailed recommendations or
specifications related to waterproofing design or minimizing the poter-Aial for infestations of
mold and mildew are desired.
Is The General, Slabs -On -Grade, and Drainage Considerations sections should be reviewed
for additional recommendations related to the control of. groundwater and excess water
vapor for the anticipated construction.
SLABS -ON -GRADE
e The building floors can be constructed as slabs -on -grade atop firm, native, non -organic sand or on
structural fill. The subgrade soil must be in a firm, non -yielding condition at the time of slab
construction or underslab fill placement. Any soft areas encountered should be excavated and
replaced with select, imported structural fill.
4D
4D Even where the exposed soils appear dry, water vapor will tend to naturally migrate upward through
the soil to the new constructed space above it. This can affect moisture -sensitive flooring, cause
e imperfections or damage to the slab, orsimply allow excessive water vapor into the space above
4D the slab, All interior slabs -on -grade should be underlain by a Capillary break drainage layer
consisting of a minimum 4-inch thickness, of clean gravel or crushed rock that has a fines content
(percent passing the No. 200 sieve) of less than 3 percent and a sand content (percent passing the
No.4 sieve) of no more than 10 percent. Flea gravel or crushed rock are typically used for this layer.
As noted by the American Concrete Institute (ACI) in the Guides for Concrete Floor and Slab
Structures, proper moisture protection is desirable immediately below any on -grade slab that will be
covered by tile, wood, carpet, impermeable floor coverings, or any moisture -sensitive equipment or
products. ACI also notes that vapor retarders such as 6-mil plastic sheeting have been used in the
past but are now recommending a minimum 10-mil thickness for better durability and long term
performance. A vapor retarder is defined as a material with a permeance of less than 0.3 perms, as
determined by ASTM E 96. It is possible that concrete admixtures may meet this specification,
although the manufacturers of the admixtures should be consulted. Where vapor retarders are
used under slabs, their edges should overlap by at least 6 inches and be sealed with adhesive
tape. The sheeting should extend to the foundation walls for maximum vapor protection. If no
potential for vapor passage through the Slab is desired, a vapor barrier should be used. A vapor
barrier, as defined by ACI, is a product with a water transmission rate of 0.01 perms when tested in
0
GEOTECH CONSULTANTS, INC.
e
Sharma JN 18021
January 25, 2018 Page 8
e
e accordance with ASTM E 96. Reinforced membranes having sealed overlaps can meet this
requirement.
In the recent past, ACI (Section 4.1.5) recommended that a minimum of 4 inches of well -graded
compactable granular material, such as a 5/8-inch-minus crushed rock pavement base, be placed
over the vapor retarder or barrier for their protection, and as a "blotter" to aid in the curing of the
concrete slab. Sand was not recommended by ACI for this purpose. However, the use of material
over the vapor retarder is controversial as noted in current ACI literature because of the potential
that the protection/blotter material can become wet between the time of its -placement and the
installation of the slab. If the material is wet prior to slab placement, which is always possible in the
Puget Sound area, it could cause vapor transmission to occur up through the slab in the future,
essentially destroying the purpose of the vapor barrier retarder. Therefore, if there is a potential
that the protection/blotter- material will become wet before the slab is installed, ACI now
recommends that no protection/blotter material be used. However, ACI then recommends that,
because there is a potential for slab curl due to the loss of the blotter mailerial, joint spacing in the
slab be reduced, a low shrinkage concrete mixture be used, and "other measures" (steel
reinforcing, etc.) be used. ASTM E-1643-98 "Standard Practice for Installation of Water Vapor
Retarders Used in Contact with Earth or G-3ranular Fill Under Concrete Slabs" generally agrees with
the recent ACI literature. We recommend that the contractor, the project materials engineer, and
the owner discuss these issues and review recent ACI literature and ASTM E-1643 for installation
guidelines and guidance on the use of the protection/blotter material.
The Genera4 Permanent Foundation and Retaining Walls, and Drainage Considerations
sections should be reviewed for additional recommendations related to the control of groundwater
and excess water vapor for the anticipated construction.
EXCA VA TIONS AND SLOPES
Excavation slopes should not exceed the limits specified in local, state, and national government
safety regulations. Temporary cuts to a depth of about 4 feet may be attempted vertically in
unsaturated soil, if there are no indications of slope instability. However, vertical cuts should not be
made near property boundaries, or existing utilities and structures. Based upon Washington
Administrative Code (WAC) 296, Part N, the soil at the subject site would generally be classified as
Type B. Therefore, temporary cut slopes greater than 4 feet in height should not be excavated at
an inclination steeper than 1: 1 (Horizontal:Vertical), extending continuously between the top and
the bottom of a cut.
The above-recom mended temporary slope inclination is based on the conditions exposed in our
explorations, and on what has been successful at other sites with similar soil conditions. It is
possible that variations in soil and groundwater conditions will require modifications to the
inclination at which temporary slopes can stand. Temporary cuts are those that will remain
unsupported for a relatively short duration to allow for the construction af foundations, retaining
walls, or utilities. Temporary cut slopes should be protected with plasfic sheeting during wet
weather. It is also important that surface runoff be directed away from the top of temporary slope
cuts. Cut slopes should also be backfilled or retained as soon as possible to reduce the potential
for instability. Please note that sand can cave suddenly and without warning. Excavation,
foundation, and utility contractors should be made especially aware of this potential danger. These
recommendations may need to be modified if the area near the potential cuts has been disturbed in
the past by utility installation, or if settlement -sensitive utilities are located nearby.
GEOTECH CONSULTANTS, INC.
Sharma
January 25, 2018
JN 18021
Page 9
All permanent cuts into native soil should be inclined no
slopes should also not be constructed with an inclination
potential for shallow sloughing, fill must be Compacted to
accomplished by overbuilding the Compacted fill and then
Adequate compaction of the slope face is important for
prevent excessive settlement of patios, slabs, foundation
placed near the edge of the slope.
steeper than 2:1 (H:V). Compacted fill
greater than 2:1 (H:V). To reduce the
the face of these slopes. This can be
trimming it back to its final inclination.
long-term stability and is necessary to
s, or other improvements that may be
Water should not be allowed to flow uncontrolled over the top of any temporary or permanent
slope. All permanently exposed slopes should be seeded with an appropriate species of vegetation
to reduce erosion and improve the stability of the surficial layer of soil.
DRAINAGE CONSIDERATIONS
e Footing drains should be used where: (1) Crawl spaces or basements will be below a structure; (2)
45 A slab is below the outside grade; or, (3) The outside grade does not slope downward from a
building. Drains should also be placed at the base of all earth -retaining walls. These drains should
be surrounded by at least 6 inches of 1-inch-minus, washed rock that is encircled with non -woven,
geotextile filter fabric (Mirafi 140N, Supac 4NP, or similar material). At its highest point, a
perforated pipe invert should be at least 6 inches below the bottom of a slab floor or the level of a
crawl space. The discharge pipe for subsurface drains should be sloped for flow to the outlet point.
Roof and surface water drains must not discharge into the foundation drain system, See Plate 2 for
other recommendations regarding subsurface drains.
As a minimum, a vapor retarder, as defined in the Slabs -On -Grade section, should be provided in
any crawl space area to limit the transmission of water vapor from the underlying soils. Crawl space
grades are sometimes left near the elevation of the bottom of the footings. As a result, an outlet
drain is recommended for all crawl spaces to prevent an accumulation of any water that may
bypass the footing drains. Providing even a few inches of free draining gravel underneath the vapor
retarder limits the potential for seepage to build up an top of the vapor retarder.
The excavation and site should be graded so that surface water is directed off the site and away
from the tops of slopes. Water should riot be allowed to stand in any area where foundations,
slabs, or pavements are to be constructed. Final site grading in areas adjacent to the residence
should slope away at least 2 percent, except where the area is paved. Surface drains should be
provided where necessary to prevent ponding of water behind foundation or retaining walls. A
discussion of grading and drainage related to pervious surfaces near walls and structures is
contained in the Foundation and Retaining Walls section. Water from roof, storm water, and
foundation drains should not be discharged onto slopes; it should be tight lined to a suitable outfall
located away from any slopes.
GENERAL EARTHWORK AND STRUCTURAL FILL
All building and pavement areas should be stripped of surface vegetation, topsoil, organic soil, and
other deleterious material. The stripped or removed materials should not be mixed with any
materials to be used as structural fill, but they could be used in non-structural areas, such as
landscape beds. The onsite sand soils can be used as structural fill provided they do contain
organics and are in a moist condition.
GEOTECH CONSULTANTS, INC.
Sharma A 18021
January 25, 2018 Page 10
Structural fill is defined as any fill, including utility backfill, placed under, or close to, a building,
behind permanent retaining or foundation walls, or in other areas where the underlying soil needs
to support loads. All structural fill should be placed in horizontal lifts with a moisture content at, or
near, the optimum moisture content. The optimum moisture content is that moisture content that
results in the greatest compacted dry density. The moisture content of fill is very important and
must be closely controlled during the filling and compaction process. The allowable thickness of the
fill lift will depend on the material type selected, the compaction equipment used:, and the number
of passes made to compact the lift. The loose lift thickness should not exceed 12 inches. We
recommend testing the fill as it is placed. If the fill is not sufficiently compacted, it can be
recompacted before another lift is placed. This eliminates the need to remove the fill to achieve the
required compaction. Fills placed on sloping ground should be keyed into the competent soils. This
is typically accomplished by placing and compacting the structural fill on level benches that are cut
into the competent soils.
The following table presents recommended relative compactions for structural fill:
Beneath footings, Slabs 95%
or walkways I
Filled slopes and behind 90%
retainina walls I
95% for upper 12 inches of
Beneath pavements subgrade; 90% below that
level
Where: Minimum Relative Compaction is the ratio, expressed in
percentages, of the compacted dry density to the maximum dry
density, as determined in accordance with ASTM Test
Designation D 1557-91 (Modified Proctor).
LIMiTATIONS
The conclusions and recommendations contained in this report are based on site conditions as they
existed at the time of our explorations and assume that the soil and groundwater conditions
encountered in earlier explorations on and near the subject site are representative of subsurface
conditions on the site. If the subsurface conditions encountered during construction are significantly
different from those observed in our explorations, we should be advised at once so that we can
review these conditions and reconsider our recommendations where necessary. Unanticipated
conditions are commonly encountered on construction sites and cannot be fully anticipated by
merely taking samples in explorations. Subsurface conditions can also vary between exploration
locations. Such unexpected conditions frequently require making additional expenditures to attain a
properly constructed project. It is recommended that the owner consider providing a contingency
fund to accommodate such potential extra costs and risks. This is a standard recommendation for
all projects.
This report has been prepared for the exclusive use of Amit Sharma and his representatives for
specific application to this project and site. Our conclusions and recommendations are professional
opinions derived in accordance with our Understanding of current local standards of practice, and
within the scope of our services. No warranty is expressed or implied. The scope of our services
does not include services related to construction safety precautions, and our recommendations are
not intended to direct the contractor's methods, techniques, sequences, or procedures, except as
specifically described in our report for consideration in design. Our services also do not include
GEOTECH CONSULTANTS, INC.
Sharma JN 18021
January 25, 2018 Page 11
assessing or minimizing the potential for biological hazards, such as mold, bacteria, mildew and
fungi in either the existing or proposed site development.
ADL)ITIONAL SERVICES
In addition to reviewing the final plans, Geotech Consultants, Inc. should be retained to provide
geotechnical consultation, testing, and observation services during construction. This is to confirm
that subsurface conditions are consistent with those indicated by our exploration, to evaluate
whether earthwork and foundation construction activities comply with the general intent of the
recommendations presented in this report and to provide suggestions for design changes in the
event subsurface conditions differ from tho�e anticipated prior to the start of construction. However,
our work would not include the supervision or direction of the actual work of the contractor and its
employees or agents. Also, job and site safety, and dimensional measurements, will be the
responsibility of the contractor. During the construction phase, we will provide geotechnical
observation and testing services when requested by you or your represeritatives. Please be aware
that we can only document site work we actually observe. It is still the responsibility of your
contractor or on -site construction team to verify that our recommendations are being followed,
whether we are present at the site or not.
We trust that this letter meets your immediate needs for the proposed development. Please contact
us if we can be of further service.
Respectfully submitted,
GEOTECH CONSULTANTS, INC.
0'1/25/18
D. Robert Ward, P.E.
Principal
Attachments: Site Exploration — Plate 1
Footing Drain Detail — Plate 2
2013 Test Pits and Boring Logs
DRW:kg
GEOTECH CONSULTANTS, INC.
. . . . . . . . . .
7-m 34
... . .......
IN,
WN
by
NJ,
dr
'Poe, W.
CL
X15,
PM Ls;:.
vt . . . ... ..... "
apr
I
4�
CL
a)
�: o
a)
cu
U)
a)
0
z
>
<
co
PLO
c
0
c\i E
-0
w
CD
co
c te tl,. f, t,
Slope backfill away from
foundation. Provide surface
drains where necessary.
Tightline Roof Drain
(Do not connect to: footing drain)
Backfill
(See text for
requirements)
Washed Rock
(7/8" min. size)
HUM
Nonwoven Geotextile
Filter Fabric -
Possible Slab
C 'o C)
�Oc:
0 .0 .0,7
4" Perforated Hard PVC Pipe
(Invert at least 6 inches below
slab or crawl space. Slope to
drain to appropriate outfall.
Place holes downward.)
Vapor Retarder/Barrier and
Capillary Break/Drainage Layer
(Refer to Report text)
NOTES:
(1) In crawl spaces, provide an outlet drain to prevent buildup of water that
bypasses the perimeter footing drains.
(2) Refer to report text for additional drainage, waterproofing, and slab- considerations.
GEOTECH
CONSULTANTS, INC.
FOOTING DRAIN DETAIL
15712 - 72nd Avenue West
Edmonds, Washington
Job No:
Date:
1
Plate:
18021
January20181
1 2
5
10
5
10
e o\�e"\e cci
TEST PIT 5
Topsoil over;
Description
Brown, slightly silty, gravelly SAND, few organics, loose to moist
-becomes mostly gray, no organics, moist, dense
• Test Pit terminated at: 4.0 feet on July 3, 2013.
• No groundwater seepage was observed during excavation.
• No caving observed (luring excavation.
C)s
/\00
TEST PIT 6
Description
Gray, very gravelly SAND, coarse grained, medium dense
-becomes dense
• Test Pit terminated at 3.0 feet on July 3, 2013.
• No groundwater seepage was observed during excavation.,
• No caving observed during excavation.
GEOTECH
CONSULTANTS, INC.
TEST PIT LOG
15620 72nd Avenue West
Edmonds, Washington
Job Date: Logged by.,
13245 1 July 2013 1 DRWIP/ate: 5j
5
10
TEST PIT 7
'o� o
CP Description
Topsoil over;
Brown, slightly silty, gravelly SAND with organics, loose to medium dense
-becomes dense, more gray, no organics
• Test Pit terminated at 4.0 feet on July 3, 2013.
• No groundwater seepage was observed during excavation.
• No caving observed during excavation.
GEOTECH
CONSULTANTS, INC.
TEST PIT LOG
15620 72nd Avenue West
Edmonds, Washington
Job Date: Logged by. Plate:
13245 1 July 2013 1 MA/ 1 :6]
e
e
e
e
e
e
e
e
e
e
e
e
e
e
e
e
e
e
e
e
e
�Y
5
1 50/411
2 24
BORING I
Brown/mottled, silty, SAND'with-graviel,
-lens of silt
Brown, gravelly SAND, some silt,'come-gained,-wet, dense -
Gray, silty SAND, very fine-grained, wet,.ffiediurn-dense
�bacomes less -silty, moist
3
25
:SM
T
-becomes wet
20
-lens Of Silt
4
20
X
25
Gray SAND, medium -grained, moist, dense
5
53
30
Test boring was terminated at 26.5 feet below grade on 1-18-97,
Groundwater seepage was'encountered at 3' during drilling.
35
- .. r—_ - _ __ - ... -, - .. - -1 .- - - - - __. _ . ..... .........
40
GEOTECH
CONSULTANTS, INC.
TEST BORING LOG
15620 - 76TH AVENUE WEST
EDMOND,'� WA
Job,Vo: Date., Loggedby., P/ars:
13245 JAN Y997
Section VII — Other Permits
Sharma Residence 18044.20
Drainage Report
Section VII — Other Permits
Section VII Summary:
Narrative
This project will not require permits beyond those required from the City of Edmonds.
August 21, 2018
Section VII, Page 1
250 4th Avenue South, Suite 200
Edmonds, WA 98020
rENGINkRING ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Section VIII -- Operation and
Maintenance Manual
Sharma Residence 18044.20
Drainage Report
August 21, 2018
Section VIII, Page 1
Section Vill — Operation and Maintenance Manual
Section Vill Summary:
Narrative
The Operation and Maintenance Manual is a standalone document that will be given to the homeowner
following the construction of the project. The contractor will be responsible for the maintenance and
operation of all stormwater structures and BMPs requiring maintenance during construction and, after
construction, responsibility will pass to the homeowner. Upon request by the City of Edmonds, it shall
be made available for their inspection. It is generally expected that few to none of these defects will be
present upon the yearly inspection of each facility.
250 4th Avenue South, Suite 200
Edmonds, WA 98020
1ENGINCEERING ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
Sh�irma Residence
15712 72nd Ave W
Edmonds, WA 98026
OPERATION AND MAINTENANCE MANUAL
Date: August 2018
August 21, 2018
Section V111, Page 2
250 4th Avenue South, Suite 200
Edmonds, WA 98020
ENoINE-EIRING ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Sharma Residence 18044.20 August 21, 2018
Drainage Report Section Vill, Page 3
Operation and Maintenance Manual
This Operation and Maintenance Manual has been created for Sharma Residence, a new single-family
residence on a 0.52 ac lot located at 15712 72 d Ave W, Edmonds, WA 98026. The proposed stormwater
management system consists of conveyance pipes and catch basins that collect roof and yard runoff and
route it to a downstream conveyance system within the access and utility easement recorded with the
existing short plat. Included in this Operation and Maintenance Manual is an 11" x 1.7" grading and
drainage plan sheet showing the locations of the infiltration system and catch basins. Please note that
this map is generated during the design phase. and may not reflect all changes made in permitting and
construction. CG Engineering may be contacted for an updated copy of this map once the as -built
drawings are completed for the site. The contractor will be responsible for the maintenance and
operation of all stormwater structures and BIVIPs requiring maintenance during construction and, after
construction, responsibility will pass to the homeowner.
Included in this manual are maintenance sheets taken from the 2014 Stormwater Management Manual
for Western Washington. Maintenance sheets are included for the following facilities/activities:
Catch Basins: Concrete structures with steel grates that collect stormwater runoff from the site
and act as junctions for storm conveyance pipes. See "No. 5" for maintenance.
Vegetation Management: Landscaping can include grading, soil transfer, vegetation removal,
pesticide and fertilizer applications, and watering. Stormwater contaminants include toxic
organic compounds, heavy metals, oils, total suspended solids, coliform bacteria, fertilizers, and
pesticides.
Facilities shall be inspected for defects listed in the following facility sheets.
Most maintenance tasks are generally reactionary to a defect being found, rather than a matter of
constant upkeep. It is generally expected that few to none of these defects will be present upon the
yearly inspection of each facility. The facility sheets list the potential conditions warranting maintenance
and the expected result following any mainter,ance. Several engineer's notes for specific tasks are
provided within the facility sheets. Unless otherwise noted on the facility sheets the maintenance tasks
should be performed on an "as needed" basis:
(a) When the described defect is visible to whomever performs the yearly inspection,
(b) Should any defect become apparent between inspections.
250 4th Avenue South, Suite 200
Edmonds, WA 98020
1ENGINCEEFUNG ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
Sharma Residence 18044.20
Drainage Report
SAMPLE ACTIVITY LOG
August 21, 2018
Section V111, Page 4
T
V
T
L LIN x
NTENANCEPERFORMED
-ZA t�'
--fit-MUL
250 4th Avenue South, Suite 200
r) 4M Edmonds, WA 98020
rENGIN&RIM ph. 425.778.8500 1 f. 425.778.5536
1 www.cgengineering.com
No. 5 — Catch Basins
Maintenance
Defect
Conditions; When Maintenance is Needed
Results Expected When
Component
Maintenance is
performed
General
Trash &
Trash or debris which is located immediately
No Trash or debris located
Debris
in front of the catch basin opening or is
immediately in front of
blocking inletting capacity of the basin by
cat&). basin or on grate
more than 10%.
opening.
Trash or debris (in the basin) that exceeds 60
No trash or debris in the
percent of the sump depth as measured from
catch basin.
the bottom of basin to invert of the lowest
pipe into or out of the basin, but in no case
less than a minimum of six inches clearance
from the debris surface to the invert of the
lowest pipe.
Trash or debris in any inlet or outlet pipe
Inlet and outlet pipes free
blocking more than 113 of its height.
of trash or debris.
Dead animals or vegetation that could
No dead animals or
generate odors that could cause complaints
vegetation present within
or dangerous gases (e.g., methane).
the Catch basin.
Sediment
Sediment (in the basin) that exceeds 60
No sediment in the catch
percent of the sump depth as measured from
basin
the bottom of basin to invert of the lowest
pipe into or out of the basin, but in no case
less than a minimum of 6 inches clearance
from the sediment surface to the invert of the
lowest pipe.
Structure
Top slab has holes larger than 2 square
Top slab is free of holes
Damage to
inches or cracks wider than 1/4 inch
and cracks.
Frame and/or
Top Slab
(intent is to make sure no material is running
into basin).
Frame not sifting flush on top slab, i.e.,
Frame is sitting flush on
separation of more than 3/4 inch of the frame
the riser rings or top slab
from the top slab. Frame not securely
and firimly attached.
attached
Fractures or
Maintenance person judges that structure is
Basin replaced or repaired
Cracksin
unsound.
to design standards.
Basin Walls/
Bottom
Grout fillet has separated or cracked wider
Pipe is regrouted and
than 1/2 inch and longer than 1 foot at the
secure at basin wall.
joint of any inlet/outlet pipe or any evidence of
soil particles entering catch basin through
cracks.
Settlement/
If failure of basin has created a safety,
Basin replaced or repaired
Misalignment
function, or design problem.
to design standards.
Vegetation
Vegetation growing across and blocking more
No vegetation blocking
than 10% of the basin opening.
opening to basin.
Vegetation growing in inlet/outlet pipe joints
No vegetation or root
that is more than six inches tall and less than
growth present.
six inches apart.
Contamination
See "Detention Ponds" (No. 1).
No pollution present.
and Pollution
Volume V— Runoff Treatment BMPs — December 2014
4-38
No. 5 — Catch Basins
Maintenance
Defect
Conditions; When Maintenance is Needed
Results Expected When
Component
Maintenance is
performed
Catch Basin
Cover Not in
Cover is missing or only partially in place.
Catch basin cover is
Cover
Place
Any open catch basin requires maintenance.
closed
Locking
Mechanism cannot be opened by one
Mechanism opens with
Mechanism
maintenance person with proper tools. Bolts
proper tools.
Not Working
into frame have less than 1/2 inch of thread.
Cover Difficult
One maintenance person cannot remove lid
Cover can be removed by
to Remove
after applying normal lifting pressure.
one maintenance person.
(Intent is keep cover from sealing off access
to maintenance.)
Ladder
Ladder Rungs
Ladder is unsafe due to missing rungs, not
Ladder meets design
Unsafe
securely attached to basin wall,
standards and allows
misalignment, rust, cracks, or sharp edges.
maintenance person safe
access.
Metal Grates
Grate opening
Grate with opening wider than 7/8 inch.
Grate opening meets
(if Applicable)
Unsafe
design standards.
Trash and
Trash and debris that is blocking more than
Grate free of trash and
Debris
20% of grate surface inletting capacity.
debris.
Damaged or
Grate missing or broken member(s) of the
Grate is in place and
Missing.
grate.
meets design standards.
Volume V— Runoff Treatment BMPs — December 2014
4-39
S411 BMPs for Landscaping and Lawn/ Vegetation Management
Description of Pollutant Sources: Landscaping can include grading, soil
transfer, vegetation removal, pesticide and fertilizer applications, and
watering. Stormwater contaminants include toxic organic compounds,
heavy metals, oils, total suspended solids, coliform bacteria, fertilizers,
and pesticides.
Lawn and vegetation management can include control of objectionable
weeds, insects, mold, bacteria, and other pests with pesticides. Examples
include weed control on golf course lawns, access roads, and utility
corridors and during landscaping; sap stain and insect control on lumber
and logs; rooftop moss removal; killing nuisance rodents; fungicide
application to patio decks, and residential lawn/plant care. It is possible to
Volume IV - Source Control BMPs — December 2014
2-21
release toxic pesticides such as pentachlorophenol, carbarnates, and
organometallics to the environment by leaching and dripping from treated
parts, container leaks, product misuse, and outside storage of pesticide
contaminated materials and equipment. Poor management of the
vegetation and poor application of pesticides or fertilizers can cause
appreciable stormwater contamination.
Pollutant Control Approach: Control of fertilizer and pesticide
applications, soil erosion, and site debris to prevent contamination of
stormwater.
Develop and implement an Integrated Pest Management Plan (IPM) and
use pesticides only as a last resort. Carefully apply pesticides/ herbicides,
in accordance with label instructions. Maintain appropriate vegetation,
with proper fertilizer application where practicable, to control erosion and
the discharge of stormwater pollutants. Where practicable grow plant
species appropriate for the site, or adjust the soil properties of the subject
site to grow desired plant species.
Applicable Operational BMPs for Landscaping:
• Install engineered soil/landscape systems to improve the infiltration
and regulation of stormwater in landscaped areas.
• Do not dispose of collected vegetation into waterways or storm sewer
systems.
Recommended Additional Operational BMPs for Landscaping:
• Conduct mulch -mowing whenever practicable
• Dispose of grass clippings, leaves, sticks, or other collected vegetation,
by composting, if feasible.
• Use mulch or other erosion control measures on soils exposed for
more than one week during the dry season or two days during the rainy
season.
• Store and maintain appropriate oil and chemical spill cleanup materials
in readily accessible locations when using oil or other chemicals.
Ensure that employees are familiar with proper spill cleanup
procedures.
• Till fertilizers into the soil rather than dumping or broadcasting onto
the surface. Determine the proper fertilizer application rate for the
types of soil and vegetation encountered.
• Till a topsoil mix or composted organic material into the soil to create
a well -mixed transition layer that encourages deeper root systems and
drought -resistant plants.
• Use manual and/or mechanical methods of vegetation removal rather
than applying herbicides, where practical.
Volume IV - Source Control BMPs — December 2014
2-22
Applicable Operational BMPs for the Use of Pesticides:
e
0 Develop and implement an IPM (See section on IPM in Applicable
e
perational BIWTs f
0 or Vegetation Manggement) and use pesticides
only as a last resort.
e
0 Implement a pesticide -use plan and include at a minimum: a list of
e
selected pesticides and their specific uses; brands, fbrmulations,
e
application methods and quantities to be used; equipment use and
le
maintenance procedures; safety, storage, and disposal methods; and
e
monitoring, record keeping, and public notice procedures. All
procedures shall conform to the requirements of Chapter 17.21 RCW
e
and Chapter 16-228 WAC (Appendix IV-D R.7).
e
Choose the least toxic pesticide available that is capable of reducing
the infestation to acceptable levels. The pesticide should readily
degrade in the environment and/or have properties that strongly bind it
to the soil. Conduct any pest control activity at the life stage when the
pest is most vulnerable. For example, if it is necessary to use a
Bacillus thuringiens application to control tent caterpillars, apply it to
the material before the caterpillars cocoon or it will be ineffective. Any
e
method used should be site -specific and not used wholesale over a
wide area.
Apply the pesticide according to label directions. Do not apply
pesticides in quantities that exceed manufacturer's instructions.
Mix the pesticides and clean the application equipment in an area
where accidental spills will not enter surface or ground waters, and
will not contaminate the soil.
15
a Store pesticides in enclosed areas or in covered impervious
le
containment. Do not discharge pesticide contaminated stormwater or
15
spills/leaks of pesticides to storm sewers. Do not hose down the paved
areas to a storm sewer or conveyance ditch. Store and maintain
e
appropriate spill cleanup materials in a location known to all. near the
le
storage area.
le
0 Clean up any spilled pesticides. Keep pesticide contaminated waste
e
materials in designated covered and contained areas.
e
0 The pesticide application equipment must be capable of immediate
e
shutoff in the event of an emergency.
e
0 Spraying pesticides within 100 feet of open waters including wetlands,
ponds, and rivers, streams, creeks, sloughs and any drainage ditch or
channel that leads to open water may have additional regulatory
requirements beyond just following the pesticide product label.
e
Additional requirements may include:
Obtaining a discharge permit from Ecology.
e
Obtaining a permit from the local jurisdiction.
Using an aquatic labeled pesticide.
e
Volume IV - Source Control BMPs — December 2014
2-23
Flag all sensitive areas including wells, creeks, and wetlands prior to
e
spraying.
e
0 Post notices and delineate the spray area prior to the application, as
required by the local jurisdiction or by Ecology.
e
e
0 Conduct spray applications during weather conditions as specified in
the label direction and applicable local and state regulations. Do not
e
apply during rain or immediately before expected rain.
e
Recommended Additional Operational BM[Ps for the use of pesticides:
e
0 Consider alternatives to the use of pesticides such as covering or
e
harvesting weeds, substitute vegetative growth, and manual weed
e
control/moss removal.
e
0 Consider the use of soil amendments, such as compost, that are known
e
to control some common diseases in plants, such as Pythium root rot,
ashy stem blight, and parasitic nematodes. The following are three
possible mechanisms for disease control by compost addition (USEPA
Publication 530-F-9-044):
1. Successful competition for nutrients by antibiotic production;
2. Successful predation against pathogens by beneficial
microorganism; and
3. Activation of' disease -resistant genes in plants by composts.
Installing an amended soilllandscape system can preserve both the plant
system and the soil system more effectively. This type of approach
provides a soil/landscape system with adequate depth, permeability, and
organic matter to sustain itselfand continue working as an effective
stormwater infiltration system and a sustainable nutrient cycle.
0 Once a pesticide is applied, evaluate its effectiveness for possible
improvement. Records should be kept showing the effectiveness of the
e
pesticides considered.
e
0 Develop an annual evaluation procedure including a review of the
e
effectiveness of pesticide applications, impact on buffers and sensitive
15
areas (including potable wells), public concerns, and recent
e
toxicological information on pesticides used/proposed for use. If
individual or public potable wells are located in the proximity of
le
commercial pesticide applications, contact the regional Ecology
hydrogeologist to determine if additional pesticide application control
measures are necessary.
e
Rinseate from equipment cleaning and/or triple -rinsing of pesticide
e
containers should. be used as product or recycled into product.
For more information, contact the Washington State University (WSU)
Extension Home -Assist Program, (253) 445-4556, or Bio-Integral
Resource Center (BIRC), P.O. Box 7414, Berkeley, CA.94707, or EPA to
Volume IV - Source Control BMPs — December 2014
2-24
e
obtain a publication entitled "Suspended, Canceled, and Restricted
Pesticides " which lists all restrictedpesticides and the.�pecifllc uses that
are allowed.
Applicable Operational BMPs for Vegetation Management:
Use at least an eight -inch "topsoil" layer with at least 8 percent organic
matter to provide a sufficient vegetation -growing medium. Amending
existing landscapes and turf systems by increasing the percent organic
matter and depth of topsoil can substantially improve the permeability
of the soil, the disease and drought resistance of the vegetation, and
reduce fertilizer demand. This reduces the demand for fertilizers,
herbicides, and pesticides. Organic matter is the least water-soluble
form of nutrients that can be added to the soil. Composted organic
matter generally releases only between 2 and 10 percent of its total
nitrogen annuall, , and this release corresponds closely to the plant
growth cycle. Return natural plant debris and mulch to the soil, to
continue recycling nutrients indefinitely.
Select the appropriate turfgrass mixture for the climate and soil type.
Certain tall fescues and rye grasses resist insect attack because the
symbiotic endophytic fungi found naturally in their tissues repel or kill
common leaf and stem -eating lawn insects. However, they do not,
repel root -feeding lawn pests such as Crane Fly larvae, and are toxic to
ruminants such as cattle and sheep. The fungus causes no known
adverse effects to the host plant or to humans. Endophytic grasses are
commercially available; use them in areas such as parks or golf
courses where grazing does not occur. Local agricultural or gardening
resources such as Washington State University Extension office can
offer advice on which types of grass are best suited to the area and soil
type.
Use the following seeding and planting BMPs, or equivalent BMPs to
obtain information on grass mixtures, temporary and permanent
seeding procedures, maintenance of a recently planted area, and
fertilizer application rates: Temporary and Permanent Seeding,
Mulching, Plastic Covering, and Sodding as described in Volume II.
Adjusting the soil properties of the subject site can assist in selection
of desired plant species. For example, design a constructed wetland to
resist the invasion of reed canary grass by layering specific strata of
organic matters (e.g., composted forest product residuals) and creating
a mildly acidic pH and carbon -rich soil medium. Consult a soil
restoration specialist for site -specific conditions.
(t
0 Aerate lawns regularly in areas of heavy use where the soil tends to
become compacted. Conduct aeration while the grasses in the lawn are
growing most vigorously. Remove layers of thatch greater than 1/4-inch
deep.
Volume IV - Source Control BMPs — December 2014
2-25
Mowing is a stress -creating activity for turfgrass. Grass decreases its
productivity when mown too short and there is less growth of roots
and rhizomes. The turf becomes less tolerant of environmental
stresses, more disease prone and more reliant on outside means such as
pesticides, fertilizers, and irrigation to remain healthy. Set the mowing
height at the highest acceptable level and mow at times and intervals
designed to minimize stress on the turf. Generally mowing only 1/3 of
the grass blade height will prevent stressing the turf.
Irrigation:
The depth from which a plant normally extracts water depends on the
rooting depth of the plant. Appropriately irrigated lawn grasses
normally root in the top 6 to 12 inches of soil; lawns irrigated on a
daily basis often root only in the top I inch of soil. Improper irrigation
can encourage pest problems, leach nutrients, and make a lawn
completely dependent on artificial watering. The amount of water
applied depends on the normal rooting depth of the turfgrass species
used, the available water holding capacity of the soil, and the
efficiency of the irrigation system. Consult with the local water utility,
Conservation District, or Cooperative Extension office to help
determine optimum irrigation practices.
Fertilizer Management:
Turfgrass is most responsive to nitrogen fertilization, followed by
potassium and phosphorus. Fertilization needs vary by site depending
on plant, soil, and climatic conditions. Evaluation of soil nutrient
levels through regular testing ensures the best possible efficiency and
economy of fertilization. For details on soils testing, contact the local
Conservation District, a soils testing professional, or a Washington
State University.Extension office.
Apply fertilizers in amounts appropriate for the target vegetation and
at the time of year that minimizes losses to surface and ground waters.
Do not fertilize when the soil is dry. Alternatively, do not apply
fertilizers within three days prior to predicted rainfall. The longer the
period between fertilizer application and either rainfall or irrigation,
the less fertilizer runoff occurs.
Use slow release fertilizers such as methylene urea, IDBU, or resin
coated fertilizers when appropriate, generally in the spring. Use of
slow release fertilizers is especially important in areas with sandy or
gravelly soils.
Time the fertilizer application to periods of maximum plant uptake.
Ecology generall, recommends application in the fall and spring,
.Y
although Washington State University turf specialists recommend four
fertilizer applications per year.
Volume IV - Source Control BMPs — December 2014
2-26
Properly trained persons should apply all fertilizers. Apply no fertilizer
at commercial arid industrial facilities, to grass swales, filter strips, or
buffer areas that drain to sensitive water bodies unless approved by the
local jurisdiction.
Integrated Pest Management
An IPM program might consist of the following steps:
Step 1: Correctly identify problem pests and understand their life cycle
Step 2: Establish tolerance thresholds for pests.
Step 3: Monitor to detect and prevent pest problems.
Step 4: Modify the maintenance program to promote healthy plants and
discourage pests.
Step 5: Use cultural, physical, mechanical or biological controls first if
pests exceed the tolerance thresholds.
Step 6: Evaluate and. record the effectiveness of the control and modify
maintenance practices to support lawn or landscape recovery and prevent
recurrence.
For an elaboration of these steps, refer to Appendix IV-F.
Volume IV - Source Control BMPs — December 2014
2-27
MAINLAND ENGINEERING CORPORATION
CITY COPY
RESU13
APR 0 9 ?njQ
C R Y 6F � 9 �- M-AO", VnOWSE
STRUCTURAL CALCULATIONS
OF
SINGLE FAMILY DWELLING
15712 - 72 AVE. WEST,
EDMONDSIWASHINGTON
03--31-19
PRRJEC'fiV0. UR801
City of Edmonds OuRding DePa me I
r
ALL WO
RK SUBJECT
=A
LL WORK SUBJECT
T 0 -STL
0 FIELD
CTI
C INSPECTION FOR t3 -4- r%
C 0 COMPL cqQ A
ODE COMPLIANCE u
P EEPARED BY -
MAINLAND ENGINEERING CORPORATION
SUITE 204 7795 128TH STREET
MAPAALFY B.C. V3W 4E6
3-8044, PAX (604) 543-8104
APPRav-1flu,
PLAIFRAN m^"=
"c%
v a-% IMF I IN- I—H
�ww wwa 1%w%a WNW a0la -1101
014 JOBsuSJTETH STREET SURREY, B.C. V3W 4E6 �Vptclll
0
MAINLAND ENGINEERING CORPORATION
INDEX
NO
PARTICULARS
CONTENTS
PAGE
I
LOAD CALCULATIONS
1
2
BEAM CALCULATIONS
B-1 TO B-36
2 to 37
3
HEADER CALCULATIONS
H-1 TO H-2
38 to 39
4
FLOOR AND ROOF JOIST
CALCULATIONS
Jl TOJ4, Rl TO R3
40 to 46
5
BUILDING LATERAL ANALYSIS
SEISMIC ANALYSIS
47 to 50
1
WINDANALYSIS
51
6
LATERAL ANLYSIS SHEETS
FOR ROOF,UPPER FLOOR AND MAIN FLOOR
52 to 57
7
WALL LOAD CALCULATIONS
58
8
APPENDIX
A TO E
59 to 63
9
RETAINING WALL DESIGN
4 FEET, 6 FEET, 8 FEET AND 10 FEET
64 to 75
10
IMOMENT FRAME CALCULATIONS
SIMPSON SMFX1 01 2-193xl 17-L STRONG FRAME
76 to 82
11
LATERAL FORCE RESISTING SYSTEM
CALCULATION
ALONG GRID LINE #A
83 to 89
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
I s MAINLAND ENGINEERING CORPORATION
Project:
SINGLE FAMILY DWELLING
Sheet
11
Location:
15712 - 72 AVE. WEST,EDMONDS WA
Job No.:
117-19
Date:
23-Jan-19
By:
IBS
lChk:
JAB
LOAD SHEET
PER 2015 IBC (TABLE-1607.1)
FLOOR LOAD IN PSF
1-112" CONC TOPPING 18.00
BUILD UP 1.00
SHEATHING (3/4") 1.50
FLOOR JOIST 2.00
CEILING: HARD 2.00
MECH & ELECT 1.00
INSULATION: RIGID 0.00
PARTITION 10.00
misc. 0.50
TOTAL D.L. 36.00
LIVE LOAD (L.L.)" 40.00
TOTALLOAD 76.00
" LIVE LOAD (STAIRS AND EXIT WAYS) 100 PSF
ROOF LOAD IN PSF
BUILD UP/ROOFING
2.50
SHEATHING (1/2")
1.75
FLAT ROOF JOIST@16" O.C.
5.00
CEILING JOISTS
1.80
DRYWALL
2.20
INSULATION
1.00
misc.
3.75
FUTURE SOLAR PANELS
0.00
TOTAL D.L.
18.00
LIVE LOAD (L.L.)
20.00
SNOW LOAD (S.L)
25.00
TIMBER: WEST COAST USING DOUGLAS FIR
SIZE/GRADE Fb (SINGLE/REPITITIVE) Fv (PSI) E (PSI)
2 x NO. 1 1000 95 1700000
4 x NO. 1 1000 95 1700000
6 x NO. 1 1350 85 1600000
PARTITION DEAD LOAD
1/2" GYP. BOARD
4.5
STUD FRAMING
2.0
INSULATION
1.5
misc
2.0
10.0
TOTALLOAD
CONCRETE:
REINFORCED STEEL:
E)CTERIOR WALL DEAD
LOAD
STUCO
4.0
1/2" PLYWOOD
1.5
STUD FRAMING
2.3
INSULATION
1.5
1/2" GYP. BOARD
2.2
misc
1.0
TOTAL
12.5
FOUNDATIONS AND SLAB ON GRADE 28 DAYS STRENGTH = 3000 PSI
INTERMEDIATE GRADE A60 AS PER ASTM 615
ALL BARS EXCEPT #2 SHALL BE DEFORMED
WELDED WIRE MESH AS PER ASTM A 185
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
.a FO R T E�� MEMBER REPORT UPPER FLOOR PLAN, B1
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
PASSED
Overall Length: 14' 1"
0
0 P
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Results
Actual @ Location
Allowed
Result
LIDIF
Load: Combination (Patterr)
-Design
Member Reaction (Ibs)
4098 @ 2"
4570 (2.25")
Passed (90%)
1.0 D + 1.0 S (All Spans)
Shear (lbs)
3323 @ 1'5"
8571
Passed (39%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
13961 @ 6' 111/4"
21832
Passed (64%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.235 @ 7' 1/2"
0.458
Passed (L/701)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.412 @ 7' 1/2"
0.688
Passed (L/401)
1.0 D + 1.0 5 (All Spans)
Deflection criteria: LL (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 13' 11" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 13' 11" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 13' 9".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam Is assumed to have its strong laminations at the bottom of the beam. install with proper side up as indicated by the manufacturer.
Applicable calculations are based on Nos.
Supports
Bearing Length
Loads to Supports (Its)
Accessories
To I
Available
Required
Dead
Snow
Total
I - Column - SPF
3.501,
2.25'
2.02"
1782
2377
4159
1 1/4" Rim Board
2 - Column - SPIF
3.50"
2.25"
2.02"
1782
2377
4159
1 1/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/,V'3t/o
4!3' 11
N/A
10.3
1 - Uniform (PSF)
0 to 14� I" (Front)
13' 6"
18.0
25.0
Residential - Living
Areas
Member Notes
BEAM OVE DECK
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-parly certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser,com/woodproducts/docunient-librarv.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
<R SHAN KUMAR
,4AlINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : Aso
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:55:53 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
.aFORTE� MEMBER REPORT UPPER FLOOR PLAN, B2
I piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
PASSED
0
Overall Length: 26' 10"
. . . .. . .................. .... .... ......... . .. .... ........... .... ..... . ...... . .. ........
26'3*
E P
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Results
Actual 0 Location
Allowed
Result
LDF
Load., Combination (Pattern)
Member Reaction (lbs)
1165 @ 268"
2988 (2.25")
Passed (39%)
1.0 D + 1.0 S (All Spans)
Shear (lbs)
825 @ 1'5"
6708
Passed (12%)
0.90
1.0 D (All Spans)
Pos Moment (Ft-lbs)
6035 @ 13'5"
17086
Passed (35%)
0.90
1.0 D (All Spans)
Live Load Delf. (in)
0.180 @ 13'5"_
0.883
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.842 @ 13'5"
1.325
Passed (L/378)
__
1.0 D + 1.0 S (All Spans)
Deflection criteria: UL (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 26! 9" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 26' 9" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 26' 6".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
Total
Available
Required
Dead
Snow
Total
I - Stud wall - SPF
3.50"
3.50"
1-501,
922
252
1174
Blockling
2 - Stud wall - SIFF
3.50"
2.251,
1.501,
921
252
1173
11/4" Rim Board
RIM board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 26' 8 3/4"
N/A
10.3
1 - Uniform (PSF)
0 to 26' 10" (Front)
91t
18.0
25.0
Residential - Living
Areas
2 - Uniform (PLF)
0 to 26' 10" (Front)
N/A
45.0
-
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by IOZ ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design foads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KR SHAN KUMAR
MAZAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:56:02 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
- MEMBER REPORT UPPER FLOOR PLAN, B3
FO R T E' 1 piece(s) 3 1/2" x 14" 1.55E TimberStrand@ LSL
PASSED
Overall Length: 6'7"
0
2' 4'
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
J
9
0
Design Resuft
Actual @ Location
Allowed—
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
1372 @ 2' 13/4"
5206 (3.50")
Passed (26%)
-_
1.0 D + 1.0 S (All Spans)
Shear (lbs)
369 @ 3' 5 1/2"
11646
Passed (3%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)
-728 @ 2' 13/4"
25116
Passed (3%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.003 @ 0
0.200
Passed
2L 999+)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.005 @ 0
0.215
Passed
(2L/999+)
1.0 D + 1.0 S (Alt Spans)
Deflection criteria: U. (L/360) and TL (L/240).
Overhang deflection criteria: LL (0.2") and TL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 6'6' o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 66" o/c unless detailed otherwise.
Supports
Bearing Length
Loads to Supports (lbs)
Acoessorles
Total
Availlable
Required
Dead
Snow
Total
I - Stud wall - SPF
3.50"
3.50"
1.50"
617
755
1372
Blockling
2 - Stud wall - SPF
3.50"
2.25"
1.501,
175
255
430
11/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 6' 5 3/4'
N/A
15.3
1 - Uniform (PSF)
0 to 2' 3" (Front)
7'
18.0
25.0
Residential - Living
Areas
2 - Uniform (PSF)
2' 1("Fto 6) 7
5' 3"
18.0
25.0
Residential - Living
mn'
1 Area
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KAISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:56:09 AM
Forte v5.4, Design Engine: V7. 1. 1.3
UR801.4te
Page 1 of 1
- A —ad F 10 R T E` MEMBER REPORT UPPER FLOO17 PLAN, B4
I piece(s) 3 1/8" x 13 1/2" 2,4F-V4 DF Glulam
PASSED
Overall Length: 14' 1"
0
2' 11'6"
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
9
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load., Combination (pattern)
Member Reaction (Ibs)
4149 @ 13'11"
4570 (2.25")
Passed (91%)
-_
1.0 D + 1.0 S (Alt Spans)
Shear (lbs)
3436 @ 3' 5"
8571
Passed (40%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
11793 @ 8' 2 1/16"
21832
Passed (54%)
1.15
1.0 D + 1.0 S (Alt Spans)
Neg Moment (Ft-lbs)
-1645 @ 2' 13/4"
16829
Passed (10%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.147 @ 8' 3/4"
0.392
Passed (L/960)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.252 @ 8- 15/16"
1 0.589
Passed (L/560)
1.0 D + 1.0 S (Alt Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Overhang deflection criteria: LL (2L/360) and TIL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 14'o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 14'o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L 11' 5 718".
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L 2' 6 7116".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glularn is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as Indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Column - SPF
3.50"
3.50"
2.89"
2509
3368
5877
Blocking
2 - Column - SPF
3.50"
2.25"
2.04"
1785
1 2438
4223
11/4" Rim Board
Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 13' 113/4'
N/A
10.3
1 - Uniform (PSF)
0 to IV 1" (Front)
16 4 1/2"
18.0
25.0
Residential - I-Ning
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible With the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and Installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KR SHAN KUMAR
MAZAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:56:21 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
9
aFORTE� MEMBER REPORT UPPER FLOOR PLAN, B5
1 piece(s) 13/4" x 14" 2.OE Mcrollam@ LVL
PASSED
Overall Length: 22'4"
0
. . ........... . .. .. . .....
2' Y Ir 19'6"
N
All locations are measured from the outside face of left support (or left cantilever end),All dimensions are horizontal.
0
Design Results
Actual 0 Location
Allowed
Result
LDIF
Load: Combination (Pattern)
Member Reaction (Ibs)
1292 @ 2' 4 3/4"
2603 (3.50")
Passed (50%)
1.0 D + 1.0 S (All Spans)
Shear (lbs)
748 @ 3' 8 1/2"
5353
Passed (14%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)
3102 @ 12' 5 318"
10916
Passed (28%)
0.90
1.0 ID (All Spans)
Live Load Defl. (in)
0.078 @ 12' 4 7/8"
0.659
Passed (L/999+)
--
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.364 @ 12'4 1/4"
0.989
Passed (L/652)
__
1.0 D + 1.0 S (Alt Spans)
Deflection criteria: LL (L/360) and TIL (1-1240).
Overhang deflection criteria: LL (21-1360) and TL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 13'8" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 22' 3" o/c unless detailed otherwise.
Supports
Bearing Length
Loads to Supports (lbs)
Accessones
Total
Av ilable
Required
Dead
Snow
Tota I
I - Stud wall - SPIF
3.50"
3.50"
1.74"
842
450
1292
Blocking
2 - Stud wall - SPF
3.50"
2.25"
1.50"
648
182
830
1 1/4M Rim Board
Rim Board is assumed to carry all loads applied directly above It, bypassing the member being designed.
Blocking Panels are assumed to carry no loads applied directly above them and the full load Is applied to the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 22' 2 3/4"
N/A
7�2
1 - Uniform (PSF)
0 to 2' 9" (Front)
3'9'
18.0
25.0
Residential - Living
Areas
2 - Uniform (PSF)
2'9" to 22'4"
9.
18.0
25.0
Residential - Living
Front) I
I
I
I Areas
(PLF)
2' 9� to 22' 4"
N/A
I
45.0
I
-
I
Residential - Living
I
(I
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products Will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
MemberType : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:56:31 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
aFORT E " MEMBER REPORT UPPER FLOO17 PLAN, B6
1 piece(s) 5 1/8" x 13 1/2" 2'4F-V4 DF Glulam
Left cantilever length exceeds 1/3 member length or 1/2 back span length.
Overall Length: 13'9"
6-3- 13'9�
0 E
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are hotrizontal.
Design Results
Actual . Location
Allowed
Result
LDIF
Load: Combination (Pattern)
Member Reaction (lbs)
9126 @ 6' 5 1/4"
14991 (4.50")
Passed (61%)
-_
1.0 D + 1.0 S (All Spans)
Shear (lbs)
4045 @ 79"
14057
Passed (29%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
276 @ 12' 6 1/16"
35805
Passed (1%)
1.15
1.0 D + 1.0 S (Alt Spans)
Neg Moment (Ft-lbs)
-17118 @ 6'5 1/4"
27599
Passed (62%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.173 @ 0
0.429
Passed (2L/896)
I --
11.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.377 @ 0
0.644
Passed
1.0 D + 1.0 S (Alt Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Overhang deflection criteria: LL (2L/360) and TL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 13' 5" a/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 13' 5" a/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L 1, 8 7/8".
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L 13' 2 3/16".
-432 Itis uplift at support 13' 4 1/2". Strapping or other restraint may be required.
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specifled glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports Qbi)
Accessories
Total
Available
Required
Dead
snow
. Total
I - Column Cap - steel
4.50"
4.50"
2.74"
4523
604
9127
Blocking
2 - Hanger on 13 1/2" SPF beam
4.50"
Hanger'
1.50"
-150
1 1003/-283
1003/433
See note I
Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
I See Connector grid below for additional information and/or requirements.
FAILED
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : Aso
Connector: Simpson Strong -Tie Connectors
Support
I Model
Seat Length
Top Nails
Face Nails
Member Nails -FAcc.-ories
2 - Face Mount Hanger
I Connector not found
N/A
N/A
N/A
N/A
I
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 13' 4 1/2"
N/A
16.8
1 - Uniform (PSF)
0 to 13'9" (Front)
T 7 1/2"
18.0
25.0
Residential - Living
Areas
2 - Uniform (PSF)
6' 3" to 13'7"
T
18.0
25.0
Residential - Living
(Front)
Areas
13/16" (Front)
N/A
842
450
Linked from: B5,
i SuDDort I
Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blacks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC FS
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-libraty.
product application, input design loads, dimensions and support Information have been provided by Forte Software Operator
Forte Software Operator Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-3044
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:56:39 AM
Fbrte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of I
FO R T E'O' MEMBER REPORT UPPER FLOOR PLAN, B7
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
Left cantilever length exceeds 1/3 member length or 1/2 back span length.
This product failed due to an excessive uplift of -1635 lbs at support located at 9' 5".
0
Overall Length: 9'7"
4-9- 43"
0 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
5610 @ 4� 10 3/4"
7109 (3.50")
Passed (79%)
--
1.0 D + 1.0 S (All Spans)
Shear (lbs)
2465 @ 6' 2"
8571
Passed (29%)
1 .15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
0 @ N/A
N/A
Passed (N/A)
--
N/A
Neg Moment (Ft-lbs)
-9798 @ 4' 10 31,V'
16829
Passed (58%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.088 @ 0
0.326
Passed
(2L/999+)
--
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.208 @ 0
--
0,490
Passed (2L/566)
1.0 D + 1.0 S (Alt Spans)
Deflection criteria: LL (1.1360) and TL (L/240).
Overhang deflection cHterfa: LL (2L/360) and TL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 9' 6" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 9' 6" o/c unless detailed otherwise.
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 9' 5".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
I
Available
Required
Dead
Snow
Total
1 - Column - SPF
3.50"
3.50"
2.76"
3027
2582
5609
Blocking
2 - Column - SPF
3.50"
2.25"
1.501,
-924
-711
-1635
1 1/4" Rim Board
Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 9' 5 3/4"
N/A
10.3
1 - Uniform (PSF)
0 to 9- 7- (Front)
6' 9"
18.0
25.0
Residential - Living
Areas
2 - Point (lb)
13/16" (Front)
N/A
842
450
Linked from: B5,
I
I
I Support I
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products wifll be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authoCitV having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-partV cerdfied to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docunient-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KR SHAN KUMAR
MAZAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
FAILED
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
1$11 SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:56:49 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of I
E-
-aF0 R T E�5 MEMBER REPORT UPPER FLOOR PLAN, B8
1 piece(s) 3 1/8" x 13 1/2" 2.4F-V4 DF Glulam
PASSED
Overall Length: 14'7"
9
Design Resuft
Actual @ Location
Allowed -
Result
LIDIF
Load: Combination (Pattern)
Member Reaction (lbs)
3753 @ 2'7 3/4"
4648 (3.50")
Passed (81%)
--
1.0 D + 1.0 S (All Spans)
Shear (lbs)
1996 @ 3' 11"
8571
Passed (23%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
6137 @ 8' 10 5/16"
21832
Passed (28%)
1.15
1.0 D + 1.0 S (Alt Spans)
Neg Moment (R-lbs)
-2352 @ 2'7 3/4"
16829
Passed (14%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.079 @ 8' 6 15/16"
0.392
Passed (L/999±LL--
1.0 D + 1.0 S (Alt Spans)
I Total Load Defl. (in)
1 0. 129 @ 8' 7 3/4"
0.589
Passed (L/999+)
1.0 D + 1.0 S (Alt Spans)
uerection criteria: LL (L/ibu) al I L (L/240).
Overhang deflection criteria: U. (2L/360) and TL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 14' 6" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 14' 6" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L 11' 13/8".
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L 3' 9 13/16".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
I
Available
Required
Dead
Floor
Live
Snow
Total
1 - Stud wall - SPF
3.50"
3.501,
2.83"
1767
387
1986
4140
Blocking
2 - Stud wall - SPF
350"
2.2S"
1.68"
945
-71
1328 1
22731-71
1 1/4" Rim Board
Rim Board is assumed to carry all loads applied directly above It, bypassing the member being designed.
Blocking Panels are assumed to carry no loads applied directly above them and the full load Is applied to the member being designed.
Tributary
Dead
Floor Live
Snow
Loads
Location (Side)
Width
(0.90)
(1.00).
(1.15)
Comments
0 - Self Weight (PLF)
0 to 14' 5 3/4"
N/A
10.3
1 - Uniform (PSF)
0 to 14' 7' (Front)
9.
18.0
25.0
Residential - Living
Areas
Linked from: LVL
2 - Point (11
0 (Front)
N/A
201
316
BEAM (PT. 9),
Support I
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values,
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder -or framer Is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-partV certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. .
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEER CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
3/29/2019 12:37:22 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
�,�i FO R T E " MEMBER REPORT UPPER FLOOR PLAN, B9
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
PASSED
Overall Length: 9'4"
0
0 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Resutts
Actual 0 Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
1812 @ 2"
2988 (2.25")
Passed (61%)
--
1.0 D + 1 -0 11; (All Spans)
Shear (lbs)
1291 @ 1' 5"
8571
Passed (15%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
4022 @ 4' 6 3/4"
21832
Passed (18%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.029 @ 4'8"
0.300
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.051 @ 4'8"
0.450
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 9'2" a/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 9' 2" a/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 9'.
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.501,
803
1050
1853
11/4" Rim Board
2 - Stud wall - SPIF
3.50"
2.25"
1.50"
803
1050
1853
11/4" Rim Board
- RIM Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0,90)
(1.15)
0 - Self Weight (PLF)
1 1/,V'to 9'2 3/4"
N/A
10.3
_Cornments
I - Uniform (PSF)
0 to 9' 4" (Front)
9.
18.0
25.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable fares" standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woo(iproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
MemberType : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:57:06 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
1 C
F0 R T E'�; MEMBER REPORT UPPER FLOOR PLAN, B10
I piece(s) 3 1/8" x 13 1/2" 24F-V4 DIF Glulam
Left cantilever length exceeds 1/3 member length or 1/2 back span length.
This product failed due to an excessive uplift of -1271 lbs at support located at 11' 11".
Overall Length: 12'1"
0
5'3" 6-3-
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
9
0
Design Results
Actual a Location
Allowed
Result
LDIF
Load: Combination', (Pattern)
Member Reaction (Ibs)
4210 @ 5'4 3/4"
4648 (3.50")
Passed (91%)
1.0 ID + 1.0 S (All Spans)
Shear (lbs)
2633 @ 4' 11/2"
8571
Passed (31%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
0 @ N/A
N/A
Passed (N/A)
-_
N/A
Neg Moment (Ft-lbs)
-9030 @ T4 3/4"
16829
Passed (54%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0. 144 @ 0
0.360
Passed (2L/896)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
____r
0.255 @ 0
0,540
1 Passed (2L/508)
1.0 D + 1.0 S (Alt Spans)
Deflection criteria: U. (L/360) and TL (L/240).
Overhang deflection criteria: LL (2L/360) and TIL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 12'o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 12' o/c unless detafled otherwise.
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 11' 11".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glularn is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on Nos.
Supports
Bearing Length
Loads to Supports (lbs)
A=emrles
Total
Available
Required
Dead
Sri w
Total
I - Stud wall - SPF
3.50"
3.50"
3.17"
1868
2343
4211
Blocking
2 - Stud wall - SPF
3.50"
2.25"
1.501,
-526
-746
-1272
1 1/4�' Rim Board
• Rim Board Is assumed to carry all loads applied directly above It, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Tributar y
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 11' 113/4"
N/A
10.3
1 - Uniform (PSF)
0 to 2' 3" (Front)
7-
18.0
25.0
Residential - Living
Areas
2 - Uniform (PSF)
TY to 12' V
91,
18.0
25.0
Residential - Living
(Front)
I
I
I
I reas
2' 3" (Front)
N/A
I
803
I
1050
I
Linked from: B9,
I
Support 1
Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESP-1387 and/or tested in accordance with applicable AS TM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KR SHAN KUMAR
MAZAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
FAILED
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/2312019 2:57:17 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
ilgii-I F 0 R T E � MEMBER REPORT MAIN FLOOR f)LAN, B 11
1 piece(s) 6 3/4" x 18" 24F-V4 DF Glulam
PASSED
Overall Length: 27'3 112'
0
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Resuft
A�tual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
9239 @ 27' 11/2-
9872 (2.25")
Passed (94%)
-_
1.0 D + 1.0 L (All Spans)
Shear (lbs)
8078 @ 2'
21465
Passed (38%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
61496 @ 13' 7 3/4"
66473
Passed (93%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.819 @ 13'9"
0.892
Passed (L/392)
--
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
1.341 @ 13'9"
1.337
Passed (L/239)
--
, 1.0 D + 1.0 L (All Spans)
Deflection criteria: UL (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 27' 1" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 27' V o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 0.91 that was calculated using length L = 26' 9".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
Total
Available
R - equired
Dead
Floor
Live
Total
1 - Column - SPIF
6.00"
4.75"
2.14"
3675
5775
9450
11/4" Rim Board
2 - Column - SPIF
3.50"
2.25"
2.11"
3620
5 88
9308
11/4" 111m Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member belng designed.
Tributary
Dead
Floor Live
Loads
Location (Side)
Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
11/4" to 27'2 1/4"
N/A
29.5
1 - Uniform (PSF)
0 to 27' 3 1/2'
7'
34.0
60.0
Residential - Living
(Front)
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser faciffities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTIVI standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyehaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
e
System : Floor
MemberType : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Des�ign Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
Forte Software Operator 3/29/2019 12:38:33 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
Job Notes
KRlSHAN KUMAR
MAINLAND ENGINEER CONSULTANTS
CORPORATION
(604) 543-8044
—
12
FO R T E (�' MEMBER REPORT MAIN FLOOR PLAN, B12
1 piece(s) 5 1/8" x 15" 24F-V4 DF Glulam
PASSED
0
Overall Length: 14'9"
14'
N 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual 0 - Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
10264 @ 3"
10827 (3.25")
Passed (95%)
��
1.0 D + 1.0 L (All Spans)
Shear (lbs)
8117 @ 1'7 1/2"
13581
Passed (60%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
35833 @ 73 1/4"
38438
Passed (93%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.243 @ T4 1/2"
0.475
Passed (L/703)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.505 @ 74 1/2"
0.712
Passed (L/339)
1.0 D + 1.0 L (All Spans)
Deflection criteria: LL (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 14' 7" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 14'7" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 14' 3".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
Total
Available
. Required
Dead
Floor
Live
Total
1 - Column - SPF
4.50"
3.25"
3.08"
5394
5015
104ag
1114" Rim Board
2 - Column - SPF
4.50"
3.25"
3.08"
5394
5015
10409
1114" Rim Board
- Rim Board Is assumed to carry all loads applied directly above It, bypassing the member being designed -
Tributary
Dead
Floor Live
Loads
Location (Side)
Width
(0�90)
(1.00)
Comments
0 - Self Weight (PLF)
11/4" to 14' 7 31V'
N/A
18.7
1 - Uniform (PSF)
0 to 1,V 9" (Front)
10,
34.0
40.0
Residential - Living
Areas
2 - Uniform (PSF)
0 to 1V 9" (Front)
7'
34.0
40.0
��
Residential - Living
I Areas
3 - Uniform (PLF)
0 to 1V 9" (Front)
N/A
135.0
I
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products Will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authoCity having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTIM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
0 SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:57:35 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
Jq
aFORTE� MEMBER REPORT MAIN FLOOR PLAN, B 13
1 piece(s) 5 1/8" x 16 1/2" 24F-V4 DF Glulam
PASSED
0
Overall Length: 19'9"
......... .... ... ... . . ................. 11 .. .... . . ... . ......
16-1 9"
0 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
10526 @ 4 1/2"
15823 (4.75")
Passed (67%)
--
1.0 D + 1.0 S (All Spans)
Shear (lbs)
8618 @ 1' 10 1/2"
17180
Passed (50%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
48613 @ 9'9 1/4"
52330
Passed (93%)—
1.15
1.0 D + 1.0 S (All Spans)
Live Load Deft. (in)
0.472 @ 9- 10 1/2"
0.633
Passed (L/483)
--
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.915 @ 9' 10 1/2"
0.950
Passed (L/249)
--
1.0 D + 1.0 S (All Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 19'4" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 19' 7" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 0.98 that was calculated using length L = 19'.
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
A cesson - es
Total
A liable
Required
Dead
Snow
Total
1 - Column - SPF
6.001,
4.75"
3.16"
5143
5493
10636
1 1/4" Rim Board
2 - Column - SPF
6.001,
4.75n
3,16"
5143
5493
10636
1 1/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above It, bypassing the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
11/4' to IT 7 3/4-
N/A
20.5
1 - Uniform (PSF)
0 to 19' 9" (Front)
22'3"
18.0
25.0
Residential - Living
Areas
2 - Uniform (PLF)
0 to 19' 9- (Front)
N/A
100.0
-
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-partV certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:57:43 AM
Forte v5.4, Design Engine: V7.1.1.3
UP801.4te
Page 1 of 1
14
F 0 R T E " MEMBER REPORT MAIN FLOOR PLAN, B 14
1 piece(s) 5 1/8" x 12" 24F-VI4 DF Glii
PASSED
0
Overall Length: 14'7"
14'
0 [2]
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDIF
Load: Combination (Pattern)
Member Reaction (Ibs)
6377 @ 3 1/2"
6377 (1.91")
Passed (100%)
--
1.0 D + 1.0 L (All Spans)
Shear (lbs)
5474 @ 1' 3 1/2"
10865
Passed (50%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (R-lbs)
22519 @ 7 3/4"
24600
Passed (92%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.324 @ T 4 1/4"
0.471
Passed (L/524)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.609 @ 74 1/4"
1 0.706
Passed (L/278)
1.0 D + 1.0 L (All Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 14' 2" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 14' 2" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 14' 11/211.
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have Its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor
Live
Total
1 - Hanger on SPF stud wall
3.50"
Hanger'
1.911,
3106
3530
6636
See note 1
2 - Column - SPF
3.50"
2.25"
1.93"
3056
3470
6526
11/4" Rim Board
• KIM uoara is assumea to carry all loads applied cilreCUY above it, bypassing the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
- I See Connector grid below for additional information and/or requirements.
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code: IBC 2015
Design Methodology : ASD
Connediiir: Simpson Strong -Tie Connectors
Support ���Model
Seat Length
Top Nails
Face Nalis
Member N
Acc . ess . orles
I - Top Mount Hanger
I Connector not found
N/A
N/A
N/A
N/A
I
Tributary
Dead
Floor Live
Loads
Locatia�n (Side)
Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
3 1/2" to 14� 5 3/4"
N/A
14.9
1 - Uniform (PSF)
a to 14' 7- (Front)
12'
34.0
40.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to cirrumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party cerdfied to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC Is
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
0 SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:57:55 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
1 r
iW0�li F 0 R T E' MEMBER REPORT MAIN FLOOR PLAN, B 15
1 piece(s) 5 1/8" x 12" 24FA14 DF Glulam
PASSED
0
Overall Length: 14' 10"
14'3"
. . . . . . . . . .
0 9
All locations are measured from the outside face of left support (or left cantilever end),All dimensions are horizontal.
0
'Design Results
Actual 0 Location
Allowed
Result
Ll
Load: Combination (Pattim)
Member Reaction (lbs)
6387 @ 3 1/2"
6387 (1.92")
Passed (100%)
1.0 D + 1.0 S (All Spans)
Shear (lbs)
5491 @ V3 1/2"
12495
Passed (44%)
1.15
1.0 D + 1.0 S (All Spans)
Pas Moment (Ft-lbs)
22754 @ 7' 11/2"
28290
Passed (80%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defi. (in)
0.402 @ 7' 5"
0.475
Passed (L/426)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.626 @ 7' 5"
0.712
Passed (L/273)
1.0 D + 1.0 S (All Spans)
Deflection criteria: LL (L/360) and TL (1-1240).
Top Edge Bracing (Lu): Top compression edge must be braced at 14'3" a/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Botborn compression edge must be braced at 14' 3" a/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 14' 3".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glularn is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
_—Loads toi Suppoft (Ibs)
Accessories
Total
Available
Required
Dead
Floor
Live
Snow
Total
1 - Hanger on SPF stud wall
3.50"
Hanger�
1,92"
2380
593
4265
7238
See note 1
2 - Hanger on SPF stud wall
3.50"
Hanger'
1.92"
2380
593
4265
7238
See note I
At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
I See Connector grid below for addidonal information and/or requirements.
System : Floor
Member Type : Flush Beam
Building Use: Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong
-Tie Connectors
Support
Model
Seat Length
Top Nails
Face Nails
Meriber Nails
Accessorie
1 - Top Mount Hanger
Connector not found
N/A
N/A
N/A
N/A
2 - Top Mount Hanger
Connector not found
N/A
N/A
N/A
N/A
Loads
Location (Side)
Tributary
Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
3 1/2' to 14' 6 1/2"
N/A
14.9
1 - Uniform (PSF)
0 to 14' 10" (Front)
2'
34.0
Q.0
-
Residential - Living
Areas
2 - Uniform (PSF)
0 to 14� 10" (Front)
5191,
18.0
100.0
Residential - Living
I Areas
3 - Uniform (PLIF)
0 to 1,V IV' (Front)
N/A
135.0 1
-
I
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured alt
Weyerhaeuser facilities are third-partv certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurrient-library.
The product. application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
nA SUSTAINABLE FORESTRY INITIATIVE
1�1`1
1/23/2019 2:58:03 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
1 E
F 0 R T E (� MEMBER REPORT MAIN FLOOR PLAN, B 16
1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam
PASSED
0
Overall Length: 4'7"
. ... ........ ..... .. ....
0 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actuall"o Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
1440 @ 2"
2988 (2.25")
Passed (48%)
--
1.0 D + 1.0 S (All Spans)
Shear (lbs)
658 @ V 3 1/2"
7619
Passed (9%)_
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
1486 @ 2- 2 1/4"
17250
Passed (9%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.005 @ 2'3 1/2"
0.142
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.006 @ 2' 3 1/2"
0.213
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Deflection criteria: LL (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 4'5" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 4' 5" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 4' 3".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have Its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.501,
247
1260
1507
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.50"
247
1260
1507
1 1/4" Rim Board
- Rim Board Is assumed to carry all loads applied directly above It, bypassing the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0,90)
(1.15)
Comments
0 - Self Weight (PLF)
11/4" to 4' 5 3/4"
N/A
9.1
1 - Uniform (PSF)
0 to 4� 7" (Front)
5' 6"
18.0
100.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-partV certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input clesign loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:58:12 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page I of 1
17
-�40 FORT E" MEMBER REPORT MAIN FLOOR PLAN, B 17
1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam
PASSED
0
..... . ................. .....
2'6'
Overall Length: 19'10"
14.'3" Z 6"
E 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
1197 @ 17' 2 1/4"
4648 (3.50")
Passed (26%)
-_
1.0 D + 1.0 5 (Adj Spans)
Shear (lbs)
373 @ 16' 1/2"
5963
Passed (6%)
0.90
1.0 D (All Spans)
Pos Moment (Ft-lbs)
1137 @ 9' 8 13/16"
13500
Passed (8%)
0.90
1.0 D (All Spans)
Neg Moment (Ft-lbs)
-922 @ 17' 2 1/4"
13297
Passed (7%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.016 @ 19' 10"
0.200
Passed
2L 999+
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.049 @ 9' 10"
0.727
Passed (L/999+)
1.0 D (All Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Overhang deflection criteria: LL (0.2") and TL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 19' 10" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 19' 10" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L 12' 4 7/8".
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L 5' 3/8".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glularn is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
Total
. Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
3.50"
1.50"
677
140
817
Blocking
2 - Stud wall - SPF
3.50"
3.50"
1.50"
839
358
1197
Blocking
- Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 19, 101,
N/A
9.1
1 - Uniform (PSF)
17' to 19' 10"
4'9"
18.0
25.0
Residential - Living
(Front)
Areas
2 - Uniform (PSF)
0 to T 6" (Front)
2-3"
18.0
25.0
Residential - Living
1 Areas
3 - Uniform (PLF)
0 to 19' 10" (Front)
N/A
50.0
-
I
Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:58:23 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
1 E
��FO R T E�� MEMBER REPORT MAIN FLOOR FILAN, B 18
1 piece(s) 8 3/4" x 12" 24F-V4 DF Glulam
PASSED
0
Overall Length: 19'4"
......... . .... . .. . .............. - ............ ........
6' 3" 12' 6"
N 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual 0 Location
Allowed
Result
LDF
Load. Combination (Pattern)
Member Reaction (lbs)
8906 @ 6' 4 3/4"
19906 (3.50")
Passed (45%)
--
1.0 D + 1.0 S (All Spans)
Shear (lbs)
4708 @ 7' 6 1/2"
21333
Passed (22%)
1. 15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
16955 @ 14'
48300
Passed (35%)
1.15
1.0 D + 1.0 S (Alt Spans)
Neg Moment (Ft-lbs)
-20307 @ 6- 4 3/4"
37231
Passed (55%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.362 @ 0
0.426
Passed (2L/424)
--
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.378 @ 0
0.640
Passed (2L/406)
--
1.0 D + 1.0 S (Alt Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Overhang deflection criteria: LL (2L/360) and TIL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 19'3" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 19' 3" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L 9' 8 3/16".
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L 10' 9 1/2".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicabl'e calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Requ . !red
Dead
Floor
I Live
Snow
Total
I
1 - Column - SPF
3.50"
3.50"
1.57"
2699
240
6207
9146
Blocking
2 - Stud wa H - SPF
3.50"
2.25"
1.501,
1327
353
2103
3783
1 1 1/4" R�,, Boa,d
• Rim Board IS assumed to carry all loads applied directly above It, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Tributary
Dead
Floor Live
Snow
Loads
Location (Side)
Width
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
0 to IT 2 3/4"
N/A
25.5
1 - Uniform (PSF)
0 to 2' 3" (Front)
7- 1 1/2"
18.0
25.0
Residential - Living
Areas
2 - Uniform (PSF)
2' 3" to 17' 10"
1-315116-
18.0
25.0
Residential - Living
(Front)
I Areas
3 - Point (lb)
113/16" (Front)
N/A
247
1260
Linked from: B16,
Support I
4 - Point (lb)
2' 3" (Front)
N/A
247
-
1260
Linked from- B16,
Support 1
5 - Point (lb)
14' (Front)
N/A
2380
593
4265
Unked from: B15,
I
Support 2
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-partV certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docunient-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
0 SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:58:32 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
is
��FORTE` MEMBER REPORT MAIN FLOOR PLAN, B 19
1 piece(s) 5 1/2" x 12" 24F-%f4 DF Glulam
PASSED
0
Overall Length: 19'7"
.19,
N
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
E
0
Design Results
Actual @ Location
Allowed
Result
UDIF
Load: Combination (Pattern)
Member Reaction (lbs)
3401 @ 2"
5259 (2.25")
Passed (65%)
1.0 D + 1.0 L (All Spans)
Shear (lbs)
2984 @ 1' 3 1/2"
11660
Passed (26%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
16260 @ 9'8 1/4"
26400
Passed (62%) -
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.542 @ 9' 9 1/2'
0.642
Passed (L/426)
--
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.761 @ 9'9 1/2"
0.962
Passed (L/304)
__
1.0 D + 1.0 L (All Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at IVY a/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 19' 5" a/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 19' 3".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Beartrig Length
. Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor
Live
Total
1 - Stud wall - SPF
3.50"
2.25"
1.501,
988
2448
3436
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.50"
988
2448
3436
11/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
i
Tributary
Dead
Floor Live
Loads
Location (Side)
Width
(G.90)
(1.00)
Comments
0 - Self Weight (PLF)
11/4" to IT 5 3/4"
N/A
16.0
1 - Uniform (PSF)
0 to 19' 7" (Front)
2.6.1
34.0
100.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software Is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation Is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blacks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docuinent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FCRE5TRY INITIATIVE
Forte Software Operator 3/31/2019 7:06:42 PM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4ta
Page 1 of 1
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
—
20
�9FORTE�' MEMBER REPORT MAIN FLOOR FLAN, B20
1 piece(s) 8 3/4" x 12" 24F-V4 DF Glulam
PASSED
Overall Length: 19'6"
0
6 3" 12'6"
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
I
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
9562 @ 6'4 3/4"
13016 (3.50")
Passed (73%)
-_
1.0 D + 1.0 S (All Spans)
Shear (lbs)
8811 @ 18' 1/2"
18550
Passed (47%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
24756 @ 14' -
48300
Passed (51%)
1.15
1.0 D + 0.75 L + 0.75 S (Alt Spans)
Neg Moment (Ft-lbs)
-20306 @ 6'4 3/4"
37231
Passed (55%)
1.15
1.0 D + 1.0 5 (All Spans)
Live Load Delf]. (in)
0.362 @ 0
0.426
Passed (2L/424)
---
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.300 @ 0
0.640
Passed (2L/512)
--
1.0 D + 1.0 S (Alt Spans)
Deflection criteria: UL (L/360) and TIL (L/240).
Overhang deflection criteria: LL (2L/360) and TL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 19'5" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 19' 5" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L 10' 7".
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L 10' 2 314".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as Indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Avaliable
Re I quired
Dead
Floor
Live
Snow
Total
I - Stud wall - SPF
3.50"
3.50"
2.57"
3355
958
6207
10520
Blocking
2 - Stud wall - SPF
5.50"
4.25"
2.52"
4702
4144
2103
10949
1 1/4" Rim Board
• Rim Board Is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load !is applied to the member being designed.
Tributary
Dead
Floor Live
Snow
Loads
Location (Side)
Width�,
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PUF)
0 to 19' 4 3/4"
N/A
25.5
1 - Uniform (PSF)
0 to X 3" (Front)
7-11/2'
18.0
25.0
Residential - Uving
Areas
2 - Uniform (PSF)
2'3"(to 17' 10"
1-315/16-
18.0
25.0
Residential - Living
Front)
Areas
3 - Point (lb)
1 13/16" (Front)
N/A
247
1260
=m : B16,
4 - Point (lb)
2' 3" (Front)
N/A
247
1260
Linked from: B16,
Support 1
5 - Point (lb)
14' (Front)
N/A
2380
S93
4265
Linked from: B15,
Support 2
6 - Point (lb)
14' (Front)
N/A
921
979
-
Linked from: B19,
I
upport 1
7 -Point (1
18' (Front)
N/A
I
3106
;:d
3530
Linked from: B14,
I
Support 1
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by1CC ES
under technijcal reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTIA standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docunient-library.
The product application, input deign loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEER CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
nA SUSTAINABLE FORESTRY INITIATIVE
T
3/29/2019 12:39:16 AM
Fbrte v5.4, Design Engine: V7-1.1.3
UR801.4te
Page 1 of 1 21
�-�'F 0 R T E' MEMBER REPORT MAIN FLOOR PLAN, B19
1 piece(s) 5 1/2" x 12" 24F-V4 DF Glil
PASSED
Overall Length: 33'1 1/2"
0
Design Results
Actual 0 Location
Allowed
Result
LDF
Load: Combination (Patiern)
Member Reaction (lbs)
7411 @ 13'5 1/4"
8181 (3.50")
Passed (91%)
-_
1.0 D + 1.0 L (All Spans)
Shear (lbs)
3694 @ 14'7"
11660
Passed (32%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
11734 @ 24' 8 1/8"
26400
Passed (44%) ----1.00-
LOD + 1.0 L (Alt Spans)
Neg Moment (Ft-lbs)
-13082 @ 13'4"
20350
Passed (64%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.371 @ 23' 10 1/2"
0.651
Passed (L/632)
--
1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in)
0.495 @ 23' 119/16"
0.976
Passed (L/473)
--
11.0 D + 1.0 L (Alt Spans)
Deflection criteria: LL (1-1360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 32' 11" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 32' 11" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L 16' 4 1/4".
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L 9' 5 3/16".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
T;�l
FAvailable
Required
Dead
Floor
Lui V
Total
I - Stud wall - SPF
3.50"
2.25"
1,50"
402
1533/-508
1935/-508
11/4" Rim Board
2 - Stud wall - SPF
3.50"
3.50'
3.17"
2133
5278
7411
None
3 - Stud wall - SPF
3.50"
2.25"
1.501,
808
21191-88
2927/-88
1 1/4�' Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Floor Live
Loads
Location (Side)
Width
(0�90)
(1.00)
Comments
0 - Self Weight (PLF)
11/4" to 33' 1/4"
N/A
16.0
1 - Uniform (PSF)
0 to 33' 11/2"
2' 6"
34.0
100.0
Residential - Living
(Front)
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the si7ing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible With the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated byICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use: Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
3/31/2019 7:04:59 PM
F:brte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1 22
aFO R T E' MEMBER REPORT MAIN FLOOR f'LAN, B22
1 piece(s) 6 3/4" x 12" 24F-V4 DF Glulam
PASSED
0
Overall Length: 16'7"
. . . ... .................. .
116'
RI 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LOF
Load: Coimbinartion (Pattern)
Member Reaction (lbs)
6713 @ 2"
9872 (2.25")
Passed (68%)
-_
10 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)
5679 @ 1' 3 1/2"
14310
Passed (40%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
25443 @ 7' 7 11/16"
32339
Passed (79%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Deft. (in)
0.328 @ 8'5/8"
0.542
Passed (L/594)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.704 @ 8' 7/8"
0.813
Passed (L/277)
1.0 D + 0.75 L + 0.75 S (All Spans)
Deflection criteria: LL (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 16'5" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 16' 5" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 3".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable caloulattons are based on NDS.
Supports
:'. Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor
Live
Snow
1
Total
1 - Column - SPF
3.50"
2.25"
1.53"
3607
2944
1277
7828
1 1/4" Rim Board
2 - Column - SPF
3.50"
2.2S"
1.501,
3034
2941
501
1 6�79
1 1/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Floor Live
Snow
Loads
Location (Side)
Width
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
11/4" to 1& 5 3/4-
N/A
19.7
1 - Uniform (PSF)
0 to 16' 7" (Front)
8-101/2'
34.0
40.0
-
Residential - Living
Areas
2 - Point (lb)
4' 9" (Front)
N/A
325
-
450
Residential - Living
I
I
I
I
I Areas
3 - Point (lb)
I
4' 9" (Front)
I
N/A
I
990
I
I I
1328
Linked from:
I
Support 2
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docutnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORAT ON
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
0 SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:59:12 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
2 2
F-0 R T E " MEMBER REPORT MAIN FLOOR FLAN, B23
1 piece(s) 3 1/8" x 10 1/2" 24F-V4 DF Glulam
PASSED
Overall Length: 9'
0
8-3-
in 0
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
'Design Results
Actual @ Location
Allowed
Result
LDIF
I Load: Combination (Pattern)
Member Reaction (lbs)
4866 @ 3"
6602 (3.25")
Passed (74%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)
3197 @ 1'3"_
5797
Passed (55%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
10524 @ 4- 13/4"
13207
Passed (80%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.106 @ 4' 5 3/16"
0.283
Passed (L/961)
--
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.235 @ 4- 5"
0.425
Passed (L/434)
--
1.0 D + 0.75 L + 0.75 5 (All Spans)
Deflection criteria: U. (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 8' 10" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 8' 10" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 8' 6".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on Nos.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor
Live
Snow
Total
1 - Column - SPF
4.50"
3.25"
2.40"
2801
1598
1300
5699
1 1/4" Rim Board
2 - Column - SPF
4.50"
3.25"
1.83"_
2050
1598
706
4354
1 1/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Floor Live
Snow
Loads
Location (Side)
VVIdth
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
11/4" to 8' 10 3/4"
N/A
8.0
1 - Uniform (PSF)
0 to 9' (Front)
8! 10 1/2'
34.0
40.0
Residential - Living
Areas
2 - Uniform (PSF)
0 to V 3" (Front)
91
18.0
-
25.0
Residential - Living
I
I
I
Areas
3 - Uniform (PLF)
0 to 4� 3" (Front)
N/A
135.0
I
I
-
I
Residential - Living
Areas
4 - Point (lb)
4' 3' (Front)
N/A
1 803
1 -
1 1050
=M: B9,
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible With the overall project. Accessories (RIm Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-parly, certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by IOC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:59:28 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
24
WaFORTEI� MEMBER REPORT MAIN FLOOR PLAN, B24
1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam
PASSED
Overall Length: 13' 1"
+
0
.. ................ .. ... . ... ......... ....
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual @ Location
Aflowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
11660 @ 3' 2 1/2"
16656 (5.00")
Passed (70%)
--
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
4945 @ 4'5"
10865
Passed (46%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
11891 @ 8'4 1/16-
24600
Passed (48%)
1.00
1.0 D + 1.0 L (Alt Spans)
Neg Moment (Ft-lbs)
-6177 @ 3- 2 1/2"
18963
Passed (33%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.081 @ 8'1/2"
0.319
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
Total Load Defl. (in)
0. 161 @ 8- 1 11/16"
0.479
Passed (L/71.5)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
Deflection criteria: LL (L/360) and TIL (L/240).
Overhang deflection criteria: LL (2L/360) and TIL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 13' o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 13' o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L 81 10 13/16".
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L 4' 3 3/8".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on Nos.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total . I
Available
Required
Dead
Floor
Live
Snow
Total
I - Column - SPF
5�0011
5.00"
3.50"
6490
3756
3137
13383
Blocking
2 - Column - SPF
5.001,
3.75"
1.901,
3455
2237/-190
1769
7461/-190
11/4" Kim Board
Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Tributary
Dead
Floor Live
Snow
Loads
Location (Side)
Width
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weighl (PLF)
0 to 12' 113/4"
N/A
14.9
1 - Uniform (PSF)
0 to 13' V (Front)
ill
34.0
40.0
Residential - Living
Areas
2 - Uniform (PSF)
0 to 13' 1" (Front)
13' 1 1/2"
18.0
-
28.0
Residential - Living
Areas
3 - Uniform (PLF)
0 to 13' V (Front)
N/A
135.0
-
Residential - Living
I
I
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible With the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks.) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-partV certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by 1CC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and Installation details refer to www.weyerhaeuser.com/woodproducts/docunient-library.
The product application, input design loads, dimensions and support information have been prcvided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:59:38 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
FO R T E 1� MEMBER REPORT MAIN FLOOR PLAN, 825
1 piece(s) 6 3/4" x 16 1/2" 24F-V4 DF Glulam
PASSED
Overall Length: 19' 10"
0
N H
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Results
Acturaii @ Location
Allowed
Result
LDF
I Load: Combination (Pattern)
Member Reaction (Ibs)
11521 @ 3 1/2"
16453 (3.75")
Passed (70%)
--
1.0 D + 1.0_1- (All Spans)
Shear (lbs)
9539 @ V 9 1/2"
19676 _
Passed (48%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Mornent (Ft-lbs)
54383 @ 9'9 3/4"
58229
Passed (93%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.421 @ 9'11"
0.642
Passed (L/548)
--
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.798 @ 9' 11" 1
0.962
--
1.0 D + 1.0 L (All Spans)
U-110. "kL/—)dllU I LkLJZW)�
Top Edge Bracing (Lu): Top compression edge must be braced at 19'a" a/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 19' 8" a/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 0.95 that was calculated using length L = 19'3".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Searind Length
Loads to Supports (lbs)
Accessories
Tot . a[
Available
Required
Dead
Floor
Live
Total
1 - Column - SPF
5.00"
3.75"
2.63"
5492
6148
11640
1-1/4" Rim Board
2 - Column - SPF
5.001,
3,75-
2.63"
5492
6148
116,40
11/4" Rim Board
- mill, D— 1b d�uinm Lo carry all ioaus appoea airecoy aoove iE, oypassing tne member being designed.
Tributary
Dead
Floor Live
Loads
Location (Side)
Width
(0,90)
(1-00)
Comments
0 - Self Weight (PLF)
I 11V' to 19' 8 3/4"
N/A
27.1
1 - Uniform (PSF)
0 to 19' 10" (Front)
15' 6"
34.0
40.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values,
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blacks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-partV certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC Es
under technical reports ESR-1153 and ESR-1387 and/or tested In accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and Installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
'H.—��—;l —
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Crxie : IBC 2015
Design Methodology: ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:59:49 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
2E
Ew;�'70_1 F 0 R T E � MEMBER REPORT MAIN FLOOR FTAN, B26
1 piece(s) 3 1/8" x 12" 24F-V4 DF Gfulam
PASSED
0
Overall Length: T3 1/2"
6-3-
E H
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
D
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
4711 @ 6' 10"
7637 (5.75")
Passed (62%)
1.0 D + 0.75 L + 0.75 5 (All Spans)
Shear (lbs)
2778 @ 1'5 1/2"
7619
Passed (36%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Pos Moment (Ft-lbs)
6903 @ 3' 5 3/4"
17250
Passed (40%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.036 @ 3' T
0.217
Passed (L/999+)
--
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.065 @ 3' 7"_
0.325
Passed (L/999+)
--
1.0 D + 0.75 L + 0.75 S (All Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 7' 1" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 7' 1" c/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 6' 6".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
Total
Available
Required
Dead
Floor .
Live
Snow
Total
I - Column - SPF
5.50"
4.25"
2.24"
2103
1433
2007
5543
11/4" Rim Board
2 - Stud wall - SPF
7.00"
5.75"
3.55"
2176
1483
2077
5736
11/4" Rim Board
- Rim Board Is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Floor Live
Snow
Loads
Location (Side)
Width
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
I 1/,V'to 7 2 1/4"
N/A
9.1
1 -Uniform PSF)
0 to 7' 3 1/2"
10,
34.0
40.0
Residential - Living
(Front)
Areas
2 - Uniform (PSF)
'0(Fr 3 "2"
7'
34.0
-
80.0
=ntial - Living
I
,it)
1
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible With the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 2:59:58 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
27
igFO R T E�� MEMBER REPORT MAIN FLOOR PLAN, B27
1 piece(s) 6 3/4" x 18" 24F-V4 DF Glulam
PASSED
0
Overall Length: 27' 1"
26' 6"
N H
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual 0 Location
Allowed
Result
LDF
Load., Combination (Pattern)
Member Reaction (lbs)
9239 @ 2"
9872 (2.25")
Passed (94%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
8078 @ V9 1/2"
21465
Passed (38%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
61496 @ 13' 5 1/4�'
66473
Passed (93%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.819 @ 13'6 1/2"
0.892
Passed (L/392)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
1.341 @ 13'6 1/2"
1.337
Passed (L/239)
1.0 D + 1.0 L (All Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 26' 11" /c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 26' 1111 o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 0.91 that was calculated using length L = 26' 911.
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on Nos.
Supports
Bearing Length
Loads to Supports (Ibs)
Accesson . es
:"I
Available
Required
Dead
Floor
Live
T otal
1 - Column - SPF
3.50"
2.25"
2.11"
3620
5688
9308
1 1/4" Rlm Board
2 - Column. - SPF
3.50"
2.25"
2.11"
3620
5688
9308
11/4" R m Board
- Rim Board is assumed to carry all loads applied directly above It, bypassing the member being designed.
Tributa!y
Dead
Floor Live
Loads
Location (Side)
Wlldth�
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
I 1/4"3to - 11
/4�6
N/A
29.5
1 - Uniform (PSF)
0 to 27' 1' (Front)
7'
34.0
60.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be In accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software Is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board,. Blocking Panels and Squash Blacks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
Forte Soitware Operator 3/29/2019 1 :05:14 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page I of 1
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
-
WIM
.aFORTE� MEMBER REPORT MAIN FLOOR PLAN, B28
A 1 piece(s) 5 1/8" x 15" 24FA14 DF Glulam
PASSED
Overall Length: 18'5"
0
. .... ......
17" 6"
19 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDIF
Load: Combination (Pattern)
Member Reaction (Ibs)
6161 @ 4"
9257 (4,25")
Passed (67%)
1.0 D + 1.0 S (All Spans)
Shear (lbs)
5075 @ 1' 8 1/2"
15618
Passed (32%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
26650 @ 9' 1 1/4"
43961
Passed (61%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.362 @ 9' 2 1/2"
0.592
Passed (L/589)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.583 @ 9' 2 1/2"
0.887
Passed (L/366)
1.0 D + 1.0 S (All Spans)
Detlection criteria: UL (L/360) and TIL (IJ240).
Top Edge Bracing (Lu): Top compression edge must be braced at 18'3" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 18' 3" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 0.99 that was calculated using length L = 179".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NOS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
I
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
5.501,
4.25"
2.83"
2362
3868
6230
1 1/4" Rim Board
2 - Stud wall - SPF
5.50"
4.25"
2.83"
2362
3868
6230
11/4" Rim Board
- Rim Board is assumed to carry ar inads appiied d1rectly above It, bypassing the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width,
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
11/4" to 18'313/4"
N/A
18.7
1 - Uniform (PSF)
0 to 18' 5' (Front)
7'
34.0
60.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other wan-anties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocl<s) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : ISC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
Forte Software Operator 3/29/2019 1:05:22 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
—
mom
i�w� F-0 R T E �� MEMBER REPORT MAIN FLOOR FLAN, B29
1 piece(s) 5 1/8" x 9" 24F-V4 DF Glulam
PASSED
Overall Length: 13' 10"
0
13' 3"
M 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Results
Actual 0 Location
Allowed
Result
LDIF
Load: Carribinatiiiin (Pattern)
Member Reaction (lbs)
3265 @ 2" -
7495 (2.25")
Passed (44%)
��
1.0 D + 1.0 L (All Spans)
Shear (lbs)
2815 @ V 1/2"
8149
Passed (35%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
10917 @ 6'9 3/4"
13838
Passed (79%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.240 @ 6- 11"—
0.450
Passed (L/675)
--
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.639 @ 6' 11"
0.675
Passed (L/254)
--
1.0 D + 1.0 L (All Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 13' 8" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 13' 8" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 13' 6".
The effects of positive or negative camber have not been accounted for when calculating defection.
The specified glularn is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
Total
Available
Required
Dead
Floor
Liv
Total
I - Column - SPF
3,50"
2.25"
1.501,
2068
1245
3313 �
11/4" Rim Board
2 - Column - SIFF
3.50"
2.25"
1.501,
2068
1245
3313
11/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Floor Live
Loads
Location (Side)
. z..
Width
-
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
1 1/4�' to 13' 8 314"
N/A
11.2
1 - Uniform (PSF)
0 to 13' 10" (Front)
2-3-
34.0
40.0
Residential - Living
Areas
2 - Uniform (PSF)
0 to 13' 10" (Front)
2'3
34.0
40.0
Resid ntial - Living
I
1
I
I Areas
(PLF)
0 to 13' 10" (Front)
I
N/A
135.0
-
Residential - Living
I
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured it
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC US
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTIA standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docunient-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 3:00:29 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of I
3C
-�,2FO R T E' MEMBER REPORT BASEMENT FLOOR PLAN, B30
1 piece(s) 3 1/8" x 12" 24F-V'4 DF Glulam
PASSED
Overall Length: 8' 1"
0
7' 6'
0 H
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Results
Actual 0 Location
Allowed
Result
LDIF
Load: Combination (Pattern)
Member Reaction (lbs)
2658 @ 2"
2988 (2.25")
Passed (89%)
1.0 D + 1.0 L (All Spans)
Shear (lbs)
1857 @ 1' 3 1/2"
6625
Passed (28%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
5069 @ 3' 111/4"
15000
Passed (34%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.036 @ 4' 1/2"
0.258
Passed (L/999+)
--
1.0 D + 1.0 L (All Spans)
I Total Load Dell. (in)
0.068 @ 4' 1/2"
0.387
Passed (L/999+)
--
1.0 D + 1.0 L (All Spans)
Deflection criteria: U. (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 7' 11" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 7' 11" o/c unless detailed otherwise.
Critical positive moment acUusted by a volume factor of 1.00 that was calculated using length L = 7' 9".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Suppoft
Bearing Length
Loads to Supports (lbs)
Accessories
Total
Aval I labile
Required
Dead
Floor
Live
tal
1 - Stud wall - SPIF
3.50"
2.25"
2.001,
1273
1455
2728
11/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
2.00"
1273
1455
2728
11/4" Rim Board
- Rim Board is assumed to carry all loads applied directly abcve it, bypassing the member being designed.
Tributary
Dead
Floor Live
Loads
Location (Side)
Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
1 11,V' to 7' 113/4"
N/A
9.1
1 - Uniform (PSF)
0 to 8' 1" (Front)
T
34.0
40.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a cle gn
professional as determined by the authority having Jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blacks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product Ilte,ature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions aridi support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KR SHAN KUMAR
MAZAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
0 SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 3:00:41 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
31
�9FD R T E " MEMBER REPORT BASEMENT FLOOR PLAN, B31
1 piece(s) 5 1/8" x 16 1/2" 24F-V4 DF Glulam
PASSED
0
Overall Length: 17' 1/2"
16'3"
0 2
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual 0 Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
15293 @ 3 1/2"
15293 (4.59")
Passed (100%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)
11367 @ 1'8"
14939
Passed (76%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
46796 @ 8' 11/2'
46186
Passed (101%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.398 @ 8'5 5/16"
0.546
Passed (L/493)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.777 @ 8' 5 3/16"
0.819
Passed (L/253)
1.0 D + 0.75 L + 0.75 S (All Spans)
Deflection criteria: LL (1-1360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at VIT' o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 16' 8" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 0.99 that was calculated using length L = 16' 4 1/211.
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glularn is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
Total
Available
Required
Dead
Floor
Live
Snow
Total
1 - Hanger on SPF stud wall
3,50"
Hanger'
4.59"
7771
6175
4525
18471
See note 1
2 - Column - SPF
6.00"
4.75"
4.25"
6918
6156
3634
16708
11/4" Rim Board
RIM Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
At hanger supports, the Total Bearing climendion Is equal to the width of the material that Is supporting the hanger
I See Connector grid below for addibonal information and/or requirements.
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie Connectors
Support
Model
Seat Length
Top Nails
Face Nails
Member Nails
Accessories
I - Top Mount Hanger
Connector not found
N/A
/A
Tributary
Dead
Floor Live
Snow
Loads
Location (Side)
Width
(0.90)
(1,00)
(1.15)
Comments
0 - Self Weight (PLF)
3 1/2"lt/, 11
N/A
20.5
4!6'
1 - Uniform (PSF)
0 to 17' 1/2"
91
34.0
40.0
-
Residential - Living
(Front)
Areas
2 - Uniform (PSF)
0 to 17' 1/2'
4�
18.0
80.0
Residential - Living
(Front)
1
Areas
3 - Uniform (PSF)
0 to 4' (Front)
91
34.0
40.0
-
Residential - Living
Areas
4 - Uniform (PSF)
12' 6' to 16' 10"
9�
34.0
40.0
-
Residential - Living
(Front)
Areas
5 - Uniform (PSF)
0 to 4' (Front)
7'
18.0
-
25.0
Residential - Living
Areas
6 - Point (11b)
4' (Front)
N/
2801
1598
1300
Linked from: B23,
I
I
I
I SUDDOrt 1
7 - Point (lb)
12' 6" (Front)
N/A
I
2050
i
1598
I
706
I
Linked from: B23,
I
SuoDort 2
Weyerhaeuser Notes
Weyerhaeuser warrants that the si7ring of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC IS
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 3:00:52 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
-�-4 F 0 R T E' MEMBER REPORT BASEMENT FLOOR PLAN, 832
1 piece(s) 6 3/4" x 15" 24F-V14 DF Glulam
PASSED
Overall Length: 24'9 1/2"
E 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Wesults
Actual Ci Location
Allowed
Reisult
LDFJ
Load: Cornlidination (Pattern)
Member Reaction (lbs)
13456 @ 2' 6"
17213 (6.00")
Passed (78%)
--
11.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)
11821 @ 4'
17888
Passed (66%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
44218 @ 6'3"
47914
Passed (92%)
1.00
1.0 D + 1.0 L (All Spans)
Neg Moment (Ft-lbs)
-77 @ 2'6"
35121
Passed (0%)
0.90
1.0 D (All Spans)
Uve Load Defl. (in)
0.457 @ 12'5/8.
0.738
Passed (L/580)
--
1.0 D + 0.75 L + 0,75 S (All Spans)
rTcii�l Loa Defl. (in)
0.937 @ 12' 171, 5"
1.106
Passed (L/283)
--
1.0 D + 0.75 L + 0.75 S (All Spans)
— kL4--) ---- -
Overhang deflection criteria: LL (2L/360) and TL (2L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 24' 8" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 24' 8" o1c unless detailed othermfise.
Critical positive moment adjusted by a volume factor of 0.95 that was calculated using length L = 22' 17/16".
Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = T 6 1/8".
Upward deflection on left cantilever exceeds overhang deflection criteria.
Upward deflection on left cantilever exceeds 0.4".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Len
Loads to Supports (Ibs)
, Accessories
Total
Available
Required
Dead
Floo
Live
Snow
Total
I - Beam - SPF
6.00"
6.00"
4.69"
6791
5128
3758
156-n
�ocVing
2 - Plate on c ncrete - SPF
3.50"
2.
—
1047
767
3401
11/4" Rim Board
-- — — 1-1— — ---Y — 5 dPP11CU U11MLly dUUVe IL, uyipassing me memDer neing aesignea.
Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Tributary
Dead
Floor Live
Snow
Loads
Location (Side)
:;Width
(0.90).
(1.00)
(1.15)
Comments
0 - Self Weight (PI-F)
0 to 24� 8 1/4"
N/A
24.6
1 - Point (lb)
6' 3" (Front)
N/A
7771
6175
4525
Linked from: B31,
Support I
Weyerhaeuser N&6s
Weyerhaeuser warrants that the sizing of Its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software, Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible With the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-partv certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under techniical reports ESR-1153 and ESR-1387 and/or tested In accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Hour
Member Type : Flush Beam
Building Use : Residential
Building Cade : IBC 2015
Design Methodology: ASD
0 SUSTAINABLE FORESTRY INITLATIVE
1/23/2019 3:01:02 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
i-iiii I FORTE �' MEMBER REPORT BASEMENT FLOOR PLAN, B33
1 piece(s) 8 3/4" x 19 1/2" 24F-V4 DF Glulam
PASSED
0
Overall Length: 17'2"
16'
E E
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual loLocation
Allowed
Result
LDIF
Load: Combination (Pattern)
Member Reaction (lbs)
18478 @ 16'8 1/2"
32703 (5.75")
Passed (57%)
-_
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
15788 @ 14' 111/2"
30144
Passed (52%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)
92458 @ 7' 7 3/4"
102749
Passed (90%)—
im
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.220 @ 8'9 1/16"
0.542
Passed (L/885)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.467 @ 8'8 5/8"
0.813
1 Passed (L/417)
1.0 D + 0.75 L + 0.75 S (All Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 17'o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 17' o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 0.93 that was calculated using length L = 16' 3".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified giulam Is assumed to have Its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on Nos.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
Total
Available
Required
Dead
Floor
Live
Snow
Total
I - Column, - PSL
7.00"
5.75"
2.94"
9022
7013
3322
19357
1 1/4" Rim Board
2 - Column - PSL
7.00"
5.75"
3.25"
9411
6596
5493
21500
1 1/4" Rim Board
- RJm Board Is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Floor Live
Snow
Loads
Location (Side)
Width
(0.90),
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
11/4" to 17 3/4"
N/A
41.5
1 - Uniform (PSF)
0 to 11'3" (Front)
10' 6"
34.0
40.0
-
Residential - Living
Areas
2 - Uniform (PSF)
I V 3" to 16' 7"
4' 6'
18.0
-
80.0
Residential - Living
Front
Areas
3 - Point (lb)
9" (Front)
N/A
6490
3756
3137
Linked from- B24,
Support 1
4 - Point (b)
]E7'
11'3" (Front)
N/A
6791
5128
3758
Linked from: B32,
Support 1
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTIM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docunient-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
nA SUSTAINABLE FORESTRY INITIATIVE
IT,
1 /23/2019 3:01 :17 AM
Forte v5A, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
34
F 0 R T E " MEMBER REPORT BASEMENT FLOOR PLAN, 834
1 piece(s) 3 1/8" x 12" 24FAA DF Glulam
PASSED
Overall Length: 9'7"
0
0 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Results
Actual 0 Location
Allowed
Result
ILDIF
Load., Combination (Pattern)
Member Reaction.(Ibs)
1597 @ 2"
2988 (2.25")
Passed (53%)
-1.0 D + 1.0 S (All Spans)
Shear (lbs)
1192 @ V3 1/2"
7619
Passed (16%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
3643 @ 4' 8 1/4"
17250
Passed (21%)
1.15
1.OD + 1.OS (All Spans)
Live Load Defl. (in)
0.052 @ 4'9 1/2"
0.308
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.069 @ 4� 9 1/2"
0.463
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Deflection criteria: U. (L/360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 9'5" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 9' 5" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 9' 3".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports.
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Av ilable
Required
Dead _LSnow
I Total
1 - Stud wall - SPF
3.50"
2.25"
1.501,
409
1222
1631
1 1/4�'Rlm Board
2 - Stud wall - SPF
3.50"
2.25"
1.501,
409
1222
1631
1 1/4�'Rim Board
- Rim Board is assumed to carry all loads applied directly above It, bypassing the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0�90)
(1.15)
Comments
0 - Self Weight (PLF)
11/4" to 9' 5 3/4"
N/A
9.1
1 - Uniform (PSF)
0 to 9* 7" (Front)
4' 3"
18.0
60.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values,
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to (fircumventthe need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible With the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC 15
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KR SHAN KUMAR
MAZAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1 /23/2019 3:01 :29 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
aFORTE I, MEMBER REPORT BASEMENT FLOOR PLAN, B35
1 piece(s) 5 1/8" x 9" 24F-V4 DF Glulam
PASSED
0
Overall Length: 17' 1"
16'6"
0 2
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual 0 Lomition
Allowed
Result
LDF
Load; Combination (Pattern)
Member Reaction (lbs)
2276 @ 2"
4901 (2.25")
Passed (46%)
-_
1.0 D + 1.0 S (All Spans)
Shear (lbs)
2023 @ 1' 1/2"
9371
Passed (22%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
9459 @ 8' 5 1/4"
15913
Passed (59%)
1.15
1.0 D + 1.0 5 (All Spans)
Live Load Defl. (in)
0.521 @ 8'6 1/2"
01558
Passed (L/385)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.852 @ 8' 6 1/2"
1 0.837
Passed (L/236),
1.0 D + 1.0 S (All Spans)
Deflection criteria: UL (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 16' 11" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 16' 11" o1c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 9".
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Tota I
Available
Required
Dead
Snow
Total
I - Stud wall - SPF
3.50"
2.25"
1.50"
893
1409
2302
11/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.50"
893
1409
2302
11/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Snow
Loads
Locatio n (Side)
Width.
(O'L90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1pV3t/, 11
N/A
11.2
4!6'
1 - Uniform (PSF)
0 to 17' 1' (Front)
2' 9'
34.0
60.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software, Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisclicirion. The designer of record, builder or framer is responsible to assure that this calculation is
compatible With the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated byICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.comjwoodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
System : Floor
Member Type : Flush Beam
Building Use : Residendal
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
Forte Software Operator 3/29/2019 1:05:33 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
—
36
�F-9711 F 0 R T E �' MEMBER REPORT BASEMENT FLOOR PLAN, B36
I piece(s) 3 1/8" x 9" 24F-V4 DF Glulam
PASSED
Overall Length: 14'4"
0
0 0
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual 0 Location
Allowed
Result
LDIF
Load: Combination (Pattem)
Member Reaction (lbs)
1708 @ 2"
2988 (2.25")
Passed (57%)
��
1.0 D + 1.0 S (All Spans)
Shear (lbs)
1481 @ 1' 1/2"
5714
Passed (26%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)
5925 @ 7' 3/4"
9703
Passed (61%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.379 @ 7' 2"
0.467
Passed (L/443)
--
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.612 @ 7' 2"
0.700
Passed (L/275)
__
1.0 D + 1.0 S (All Spans)
Deflection criteria: LL (L/360) and TL (L/240).
Top Edge Bracing (Uu): Top compression edge must be braced at 14'2" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 14' 2" o/c unless detailed otherwise.
Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 14'.
The effects of positive or negative camber have not been accounted for when calculating deflection.
The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.501,
657
1075
1732
11/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25'
1.501,
657
1075
1732
11/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
11/4" to 14' 2 3/4"
N/A
6.8
1 - Uniform (PSF)
0 to 1,V 4" (Front)
2'6"
34.0
60.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainab'e forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
3/29/2019 1:05:43 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1 37
�FO R T E- MEMBER REPORT UPPER FLOOR PLAN, H1
2 piece(s) 2 x 10 Douglas Fir -Larch No. 1
Overall Length: 67"
H 0
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
1550 @ 2"
2869 (2.25")
Passed (54%)
-_
1.0 D + 1.0 S (All Spans)
Shear (lbs)
997 @ 1' 3/4"
3830
Passed (26%)
US
1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)
1987 @ 2'9 1/2"
4510
Passed (44%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.017 @ 2'9 1/2"
0.175
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.029 @ 2'9 1/2"
0.262
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Deflection criteria: LL (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 5'5" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at S'S" o/c unless detailed otherwise.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2,25"
1.50"
685
925
1610
11/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1,50"
685
925
1610
1 1/4�'Rinn Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
11/4" to S' 5 3/4"
N/A
7.0
1 - Uniform (PSF)
0 to 5' 7" (Front)
13'3"
18-0
25.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the sofbNare. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Nodding Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under techrfical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(6041543-8044
PASSED
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
nA SUSTAINABLE FORESTRY INITIATIVE
T
1/23/2019 3:07:43 AM
Forte v5,4, Design Engine: V7.1.1.3
OR801.4te
Page 1 of I
3E
W aFO R T E' MEMBER REPORT UPPER FLOOR PLAN, H2
2 piece(s) 2 x 10 Douglas Fir -.Larch No. I
PASSED
Overall Length: 8'7"
0
-1 1
0 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Results
Actual 0 Location
Allowed
Result
LDIF
Load: Combination (Pattern)
Member Reaction (lbs)
1515 @ 2"
2869 (2.25")
Passed (53%)
1.0 D + 1.0 S (All Spans)
Shear (lbs)
1168 @ 1'314"
3830
Passed (31%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)
3078 @ 4'3 1/2"
4510
Passed (68%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.064 @ 4' 3 1/2"
0.275
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.112 @ 4' 3 1/2"
0.412
Passed (L/883)
—
1.0 D + 1.0 S (All Spans)
Deflection criteria: LL (1.1360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 8'5" o/c unless detailed otherwise.
Bottom Edge Bradng (Lu): Bottom compression edge must be braced at 8'5" c/c unless detailed otherwise.
Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
A ...... rie,
Total
Available
Required
Dead
I Snow7
Total
I - Stud wall - SPF
3.50"
2.25"
1.50"
667
885
1552
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.50"
667
1 885
1552
11/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Tributary
Dead
Snow
Loads
Location (Side)
Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 8! 5 3/4'
N/A
7.0
1 - Uniform (PSF)
0 to 8' 7" (Front)
8' 3"
18.0
25.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by IOZ ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docunient-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
1/23/2019 3:07:50 AM
Forte v5.4, Design Engine: V7.1.1.3
OR801.4te
Page 1 of 1
3E
��FO R T E' MEMBER REPORT UPPER FLOOR PLAN, J1
1 piece(s) 117/8" TJI@ 560 @ 16" OC
PASSED
Overall Length: 20' 11"
0
19'6"
Ir
in 0
All locabons are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Partliarn)
Member Reaction (lbs)
981 @ 2 1/2"
1396 (2.25")
Passed (70%)
1.00
1.0 D + 1.0 L (All Spans)
Shear (lbs)
962 @ 3 1/2'.
2050
Passed (47%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)
4770 @ 10' 1/2"
9500
Passed (50%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.289 @ 10' 1/2"
0.656
Passed (L/818)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.534 @ 10' 1/2"
0.983
1 Passed (L/442)
1.0 D + 1.0 L (All Spans)
TI-Pro7" Rating
49
40
1 Passed
Deflection criteria: LL (1-1360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 8' V o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 19' 11" o/c unless detailed otherwise.
A structural analysis of the deck has not been performed.
Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeTI Panel (24" Span Rating) that is glued and nailed down.
Additional considerations for the TJ-Pro— Rating include: 5/8" Gypsum ceiling.
Supports.
Bearing Length
Loads to Supports (1110
Accessories
I
Availlable
Required
Dead
Floor
Live
Total
I - Stud wall - SPF
3.50"
2.25"
1.75"
455
536
991
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.751,
455
536
991
11/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Dead
Floor Li e
Loads
Location (Side)
Spacing
(0.90)
(1.00)
Comments
I - Uniform (PSF)
0 to 20' 1"
16"
34.0
40.0
Residential - Living
Areas
Notes
Weyerhaeuser warrants that the sizing of its products will be In accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not Intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC FS
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards, For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-Ilbrary,
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
9/1/2018 11:18:34 AIV
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 ot 1
4C
- �,�FO RT E" MEMBER REPORT UPPER FLOOR PLAN, J2
1 piece(s) 117/8" TJI@ 230 @ 16" OC
PASSED
0
Overall Length: 18'4"
17'9"
0 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual 0 Location-
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
894 @ 2 1/2"
1183 (2.25")
Passed (76%)
1.00
1.0 D + 1.0 L (All Spans)
Shear (lbs)
876 @ 3 1/2"
1655
Passed (53%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)
3959 @ 9' 2"
4215
Passed (94%)
1.00
1.0 ID + 1.0 L (All Spans)
Live Load Defl. (in)
0.332 @ 9' 2"
0.597
Passed (L/648)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.614 @ 9'2"
1 0.896
1 Passed (L/350)
1.0 D + 10 L (All Spans)
I TJ-PrOT" Rating
1 46
40
Passed
Deflection criteria: LL (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 4' 1" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 181 211 o/c unless cletalled otherwise.
A structural analysis of the deck has not been performed.
Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeTM Panel (24" Span Rating) that is glued and nailed down.
Additional considerations for the TJ-ProTm Rating include: 5/8" Gypsum ceiling.
Supports
Bearing Length
Loads to Supports (lbs)
Accessories
Total
Available
Required
Dead
Floor
Live
Total
I - Stud wall - SPF
3.50"
2.25"
1.75"
416
489
905
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.75"
416
489
905
11/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Dead
Floor Live
Loads
Location (Side)
Spacing
(0.90)
(1.00)
Comments
I - Uniform (PSF)
0 to 18' 4"
16�
340
40.0
I
Residential - Living
Areas
Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer Is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESP-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docurnent-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
�ii-104;10 -
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
9/1/2018 11:19:11 AN
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
41
F 0 R T E' MEMBER REPORT UPPER FLOOR PLAN, J3 PASSED
1 piece(s) 2 x 10 Douglas Fir -.Larch No. I @ 12" OC
Overall Length: 5'7"
0
N 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
253 @ 2 1/2"
1434 (2.25")
Passed (18%)
-_
1.0 D + 1.0 L (All Spans)
Shear (lbs)
163 @ 1' 3/4"
1665
Passed (10%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)
314 @ 2' 9 1/2"
2255
Passed (14%)
1.00
1.0 ID + 1.0 L (All Spans)
Live Load Defl. (in)
0.006 @ 2' 9 1/2"
0.172
Passed (L/999+)
--
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.009 @ 2'9 1/2"
0.258
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
TI-Pro— Rating
N/A
N/A
I --
__
Deflection criteria: LL (L/360) and TIL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 55" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 5" o/c unless detailed otherwise.
A 15% increase in the moment capacity has been added to account for repetitive member usage.
Applicable calculations are based on Nos.
No composite action between deck and joist was considered in analysis.
Supports
Bearing Length
Loads to Supports (111s)
Accessories
Total
Available
. Required
Dead
Floor
Live
Tota I
I
I - Stud wall - SPF
3.50"
2.25"
1.501,
95
167
262
1 1/4�'Rlrn Board
2 - Stud wall - SPF
3.50"
2,25"
1.50"
95
167
267
1 1/4�' Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Dead
Floor Live
Loads
Location (Side)
Spacing
(0.90)
(1.00)
Comments
1 - Uniform (PSF)
0 to 5'7"
12"
34.0
60.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the slizing of its products "fill be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this soft.ware is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
System : Floor
Member Type : loist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
Forte Software Operator 3/29/2019 4:39:45 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
,io—'�M10
42
aFO R T E` MEMBER REPORT UPPER FLOOR PLAN, J4 PASSED
2 piece(s) 2 x 10 Douglas Fir -Larch No. 1 @ 16" OC
Overall Length: 14'7"
0
i�'
i - 14'
H H
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Design Results
Actual @ Locatiod
Al , lowed
Result
LOF
Load: Combination (Pattern)
Member Reaction (lbs)
901 @ 2 1/2"
2869 (2.25")
Passed (31%)
-_
1.0 D + 1.0 L (All Spans)
Shear (lbs)
781 @ 1'3/4"
3330
Passed (23%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)
3144 @ T3 1/2"
4510
Passed (70%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0. 216 @ 7' 3 1/2"
0.472
Passed (L/789)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0. 338 @ 7' 3 1/2"
0.708
Passed (L/503)
1.0 D + 1.0 L (All Spans)
TI-ProTm Rating
N/A
N/A
Deflection criteria: UL (L/360) and TL (L/240).
Top Edge Bracing (Lu): Top compression edge must be braced at 14' 5" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 14' 5" o/c unless detailed otherwise.
A 15% increase in the moment capacity has been added to account for repetitive member usage.
Applicable calculations are based on Nos.
No composite action between deck and joist was considered in analysis.
Suppor.ts
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Availlibi
Required
Dead
Floor
Live
Total
1 - Stud wall - SPF
3.50"
2.25"
1.501,
331
583
914
1 1/4" Rim Board
2 - Stud wall - SIFF
3.50"
2.25"
1.501,
331
583
914
1 1/4Rim Board
- Rim Board Is assumed to carry all loads applied directly above it, bypassing the member being designed.
De d
Floor Live
Loads
Location (Side)
Spacing
(0.90)
(1.00)
Comments
1 - Uniform (PSF)
0 to 14' 7"
16"
34.0
I
60.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the si7ing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC 15
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docunient-library.
The product application, input design loads, dimensions and support information have been provided by Forte Software Operator
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
0I SUSTAINABLE FORESTRY INITIATIVE
Forte Software Operator 3/29/2019 4:39:51 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of I
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-80"
43
�-�'F-0 R T E " MEMBER REPORT UPPER FLOORPLAN, R1
1 piece(s) 14" TJI@ 560 @ 12" OC
PASSED
0
Overall Length: 25' 10"
25'3"
11 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
Des!4W]Resullts
Actual 0 Location
I Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (lbs)
551 @ 2 1/2"
1606 (2.25")
Passed (34%)
1.15
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
543 @ 3 1/2"
2749
Passed (20%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)
3472 @ 12'11"
12966
Passed (27%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.257 @ 12' 11"
0.847
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.442 @ 12' 11"
1271
Passed (L/690).
1
1.0 D + 1.0 S (All Spans)
1 TJ-Pro— Rating
42
0
1 Passed
Deflection criteria: LL (L/360) and TL (L/240).
Input live load span ratio deflection limit is below building code minimum value of L/360. This minimum value was used for design.
Input total load span ratio deflection limit is below building code minimum value of L/240. This minimum value was used for design.
Top Edge Bracing (Lu): Top compression edge must be braced at 10'6" o/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 25' 8" o/c unless detailed otherwise.
A structural analysis of the deck has not been performed.
Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge- Panel (24�'Span Rating) that is glued and nailed cloven.
Additional considerations for the TI-Prolm Rating include: 5/8" Gypsum ceiling, bridging or blocking at max. 8'o.c..
Supports
Bearing Length
Loads to Supports (Ibs)
Ac ries
Total
Av ilable
Required
Dead
1 Snow
-t-1
�55
I - Stud wall:- SPF
3.50"
2.25"
1.75"
233
323
]
6
11/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.75"
233
1 323
1 556
11/4' Rim Board
- Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Dead
Snow
Loads
Location (Side)
Spacing
(0�90)
(1.15)
Comments
I - Uniform (PSF)
0 to 25' 10"
12"
18.0
25.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software Is not Intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer Is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blockiing Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested In accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and Installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support Information have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
SUSTAINABLE FORESTRY INITIATIVE
9/1 /2018 11 :15:34 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
a
� --I MEMBER REPORT UPPER FLOOR PLAN, R2
. ii F-0 R T E� 1 piece(s) 14" TJI@ 560 @ 16" OC
PASSED
0
Overall Length: 22'4"
21'9"
11 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design.Results
Actual 0 Location
Allowed
Result
LoF
Load: Combination (Pattern
Member Reaction (Ibs)
634 @ 2 1/2"
1606 (2.25")
Passed (39%)
1.15
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
624 @ 3 1/2"
2749
Passed (23%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)
3442 @ 11' 2"_
12966
Passed (27%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defil. (in)
0.192 @ 11'2"
0.731
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.330 @ 11'2"
1.096
1 Passed (L/796)
1.0 D + 1.0 S (All Spans)
TI-ProT" Rating
48
1 40
1 Passed
Deflection criteria: UL (L/360) and TL (L1240).
Top Edge Bracing (Lu): Top compression edge must be braced at 10'7" a/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 22' 2" a/c unless detailed otherwise.
A structural analysis of the deck has not been performed.
Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge- Panel (24" Span Rating) that is glued and nailed down.
Additional considerations for the TJ-Pro— Rating include: 5/8" Gypsum celling.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.75"
268
372
640
11/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25'
1.75'
268
372
640
11/4" Rim Board
- Rim Board is assumed to carry all loads applied directly above It, bypassing the member being designed.
Dead
Snow
Loads
Location (Side)
Spacing
(0.90)
(1.15)
Comments
1 - Uniform (PSF)
0 to 22'4"
16"
18.0
25.0
Residential - Living
Areas
Notes
Weyerhaeuser warrants that the S12ing of Its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software, Use of this software is not Intended to circumvent the need for a design
professional as determined by the authorlity having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blacks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-partV certified to sustainable fares" standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES
under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and installation details refer to www.weyerhaeuser.com/woodproducts/docunient-library.
The product application, input design loads, dimensions and support info. mation have been provided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Joist
Building Use: Residential
Building Code : IBC 2015
Design Methodology : Aso
0 SUSTAINABLE FORESTRY INITIATIVE
9/1/2018 11:16:40 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page 1 of 1
4 E
MEMBER REPORT UPPER FLOOR PLAN, R3
4-]FORTE�
1 piece(s) 14" TH@ 230 @ 1611 OC
PASSED
Overall Length: 20' 1"
0
N 9
All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.
0
Design Results
Actual 0 Location
Allowed
Result
LIDIF
Load., Combination (Pattern)
Member Reaction (lbs)
570 @ 2 1/2"
1360 (2.25")
Passed (42%)
1.15
1.0 D + 1.0 S (All Spans)
Shear (lbs)
559 @ 3 1/2"
2237
Passed (25%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)
2772 @ 10' 1/2"
5739
Passed (48%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.208 @ 10' 1/2"
0.656
Passed (L/999+)
--
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.358 @ 10' 1/2"
0.983
Passed (L/660)
1.0 D + 10 S (All Spans)
TI-ProTm Rating
47
40
Passed
Deflection criteria: ILL (L/360) and TL (1-1240).
Top Edge Bracing (Lu): Top compression edge must be braced at 51 8" a/c unless detailed otherwise.
Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 19' 11" a/c unless detailed otherwise.
A structural analysis of the deck has not been performed.
Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeTM Panel (24" Span Rating) that is glued and nailed down,
Additional considerations for the TI-Prol" Rating include: 5/8" Gypsum ceiling.
Supports
Rearing Length
Loads to Supports (Ibs)
Accessories
Total
Av ilable
Required
Dead
Sno
Total
I - Stud wall - SPF
3.50"
2.25"
1.75"
241
335
576
11/4' Rim Board
2 - Stud wall - SPIF
3.50"
2.25"
1.75"
241
335
576
11/4" Rim Board
- RIM 13oard is assumed to carry all loads applied directly above It, bypassing the member beirg designed.
Dead
Snow
Loads
Location (Side)
Spacing
(0.90)
(1.15)
Comments
1 - Uniform (PSF)
0 to 20' 1"
16"
18.0
25.0
Residential - Living
Areas
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.
Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software Is not intended to circumvent the need for a design
professional as determined by the authority having jurisdiction. The designer of record, builder or framer Is responsible to assure that this calculation is
compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blacks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC FS
under technIcal reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser
product literature and Installation details refer to www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been prcvided by Forte Software Operator
Forte Software Operator
Job Notes
KRISHAN KUMAR
MAINLAND ENGINEERING CONSULTANTS
CORPORATION
(604) 543-8044
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
0 SUSTAINABLE FORESTRY INITIATIVE
9/1/2018 11 :17:27 AM
Forte v5.4, Design Engine: V7.1.1.3
UR801.4te
Page I of 1
4E
ASCE Seismic Base Shear
SEISMIC ANALYSIS
Risk Category Calculations per ASCE 7-10
Risk Category of Building or Other Structure : "I" : Buildings and other structures that represent a low hazard to huma�CE 7-10, Page 2, Table 1.5-1
life in the event of failure.
Seismic Importance Factor ASCE 7- 10, Page 5, Table 1.5-2
USER DEFINED Ground Motion ASCE 7-10 11.4.1
Max. Ground Motions, 5% Damping
SS 1.330 g, 0.2, sec response
S1 0,520 g, 1.0 sec response
Site Class, Site Coeff. and Design Category
Site ClassificalioYD" : Shear Wave Veloc�ty 600 to 1,200 ft/sec D ASCE7-10 Table 20.3-1
Site Coefficients Fa & Fv Fa 1.00 ASCE 7-10 Table 11.4-1 & 11.4-2
(using straight-line interpolation from table vai Fv 1.50
Maximum Considered Earthquake Accelerat S MS � Fa * S�s 1.330 ASCE 7-10 Eq. 11.4-1
Smi �Fv*Sl 0.780 ASCE 7-10 Eq. 11.4-2
Design Spectral Acceleration S S 2/3 = 0.887 ASCE 7-10 Eq. 11.4-3
DS ms
S D1 Smi 9/3 = 0.520 ASCE 7-10 Eq. 11.4-4
Seismic Design Category D 7- 10 Table 11- 6-1 & -2
Resisting System ASCE 7-10 Table 12.2-1
Basic Seismic Force Resisting System Rearing Wall Systems
13.Light-frame (wood) walls sheathed w/wood structural panels rated for shear resistance.
Response Modification Coefficient I = 6.50 Building height Limits :
System Overstrength Factor " Wo = 2.50 Category "A & B" Limit: No Limit
Deflection Amplification Factor " Cd' = 4.00 Category "C" Limit: No Limit
Category "D" Limit: Limit = 65
NOTE! See ASCE 7-10 for all applicable footn( Category "E" Limit: Limit = 65
Category "F" Limit: Limit = 65
Lateral Force Procedure 4SCE 7-10 Section 12.8.2
Equivalent Lateral Force Procedure
The "Ecluivalent Lateral Force Procedure" is being used accordina to the movisions of ASCE 7-10 12.8
Determine Building Period Use ASCE 12.8-7
Structure Type for Building Period Calcul�All Other Structural Systems
Ct " value 0.020 hn Height from base to highest leve 25.0 ft
x " value 0.75
Ta Approximate funclemental period using Eq. 12.8-7 : Ta = Ct * (hn A X) 0.224 sec
"TIL" Long -period transition period per ASCE 7-10 Maps 22-12 -> 22-16 8.000 sec
Building Period " Ta " Calculated from Approximate Method sel(= 0.224 sec
Cs Response Coefficient ASCE 7-10 Section 12. 8. 1. 1
SDS: Short Period Design Spectral Response 0.887 From Eq. 12.8-2, Preliminary Cs 0.136
R Response Modification Factor 6.50 From Eq. 12.8-3 & 12.8-4 , Cs need not exceE = 0.358
I Seismic Importance Factor 1 From Eq. 12.8-5 & 12.8-6, Cs not be less than = 0.039
Cs : Seismic Response Coefficient 0.1364
Seismic Base Shear ASCE 7-10 Section 12.8.1
Cs 0.1364 from 12.8.1.1 W (see Sum W! below) = 475.93 k
Seismic Base Shear V = Cs, * W = 64.92 k
47
� ASCE Seismic Base Shear
Vertical Distribution of Seismic Forces ASCE 7-10 Section 12.8.3
" k " : hx exponent based on Ta = 1.00
Table of building Weights by Floor Level...
Level # Wi: Weight Hi : Height (Wi - Hi,1k) Cvx Fx=Cvx * V Sum Story Shear Sum Story Moment
3 88.56 30.00 2,656.80 0.3080 19.99 19.99
0.00
2 190.58 21.00 4,002.14 0.4639 30.12 50.11
179.94
1 196.79 10.00 1,967.92 0.2281 14.81 64.92
731.18
Sum Wi 475.93 k Sum Wi * Hi = 8,626.86 k-ft Total Base Shear 64.92 k
Base Moment
= 1,380.4 k-ft
Diaphragm Forces: Seismic Design Category "B" to 7" ASCE7-10 12.10.1.1
Level # Wi Fi Sum Fi Sum \Afi Fpx: Calcd Fpx: Min Fpx: Max
Fpx Dsgn. Force
3 88.56 19.99 19.99 88.56 19.99 15.70 31.41
19.99 19.99
2 190.58 30.12 50.11 279.14 34.21 33.80 67.59
34.21 34.21
1 196.79 14.81 64.92 475.93 26.84 34.90 69.80
34.90 34.90
Wpx .................... Weight at level of diaphragm and other structure elements attached to it.
Fi ...................... Design Lateral Force applied at the level.
Sum Fi .................. Sum of "Lat. Force" of current level plus all levels above
MIN Req'd Force @ Level ... 0.20 S DS I * Wpx
MAX Req'd Force P Level. . 0.40 S DS 1 * WPX
Fpx: Design Force @ Level . Wpx SUM(x->n) Fi / SUM(x->n) wi, x = Current level, n = Top I-evel
4E
MAINLAND ENGINEERING CORPORATION
Project: ISINGLE FAMILY DWELLING Sheet 149 1 1
Location: 115712 - 72 AVE. WEST,EDMONDS WA Job No.: 17-19 1 1
Date: 123-Jan-19 By: IBS lChk: JAB
SEISMIC ANALYSIS (BUILDING)
DEAD WEIGHT OF ROOF
18
#/SQ. FT.
DEAD WEIGHT OF FLOOR
26
#/SQ. FT.
AVG. WEIGHT OF WALLS
12
#/SQ. FT.
AREA OF ROOF
3430
SQ FF.
AREA OF UPPER FLOOR
3245
SO FT.
AREA OF MAIN FLOOR
3785
SQ FT.
PARAPET WALL LENGTH AT ABOVE ROOF
300
TOTAL AVG. WALL LENGTH AT EACH FLOOR
850
HEIGHT OF WALLS UNDER ROOF FRAMING
- 9
HEIGHT OF WALLS UNDER UPPER FLOOR FRAMING
- 10
HEIGHT OF WALLS UNDER MAIN FLOOR FRAMING
9
HEIGHT OF PARAPET (AVEGAGE)
3
BUILDING WEIGHT:
WT. OF MAIN ROOF (1/2 OF WALL HT.+PARAPET)
118440
WT. OF UPPER FLOOR AND WALLS(l /2 UPPER+ 1 /2 BELOW HEIGHT)
181270
WT. OF MAIN FLOOR AND WALLS(1/2UPPER+1/2 BELOW HEIGHT)
195310
TOTAL WEIGHT OF BUILDING (W)
495020
DESIGN BASE SHEAR SEE NEXT PAGE (EQUIVALENT LATERAL FORCE PROCEDURE)
V = 0.1364 x W 0.1364 x 495020.000
67521
47265
DISTRIBUTION OF SEISMIC FORCES
FT,
FT.
FT.
FT.
FT.
FT.
# (SD)
# (ASD)
LEVEL
HT.OF
STORY "H"
WEIGHT OF
STORY"W"
WxH
4 FT.
FORCE(#)
[(WxH)xV]/(TOTAL W xH)
FORCE
(PSF)
FORCE
(PSF)
SD
ASD
ROOF
30
118440
3553200
25761
4.51
UPPER FLOOR
21
181270
3806670
-7.5
27599
8.5
5.10
MAIN FLOOR
10
.195310
.1953100
14160
13,7
2.24
1
TOTAL =
1495020
1-�9312970
167520.7
119.8
11.85
SUITE 204 7795 128TFI STREET SURREY, B.C. V3W 4E6
MAINLAND ENGINEERING CORPORATION
Project:
SINGLE FAMILY DWELLING
ISheet
150
1
Location:
15712 - 72 AVE. WEST,EDMONDS WA
lJob No.:
117-19
1
Date:
23-Jan-19
I By:
IBS
IChk:
JAB
HORIZONTAL WIND FORCE:
HORZ. WIND PRESSURE (ZONE A) 31.32
HORZ. WIND PRESSURE (ZONE C) 20.88
BUILDING LENGTH 174 FT.
BUILDING WIDTH 111 FT.
MEAN ROOF HEIGHT '13 FT.
AVG. PARAPET HEIGHT 3 FT.
a 5.2 FT.
PARAPET WIND PRESSURE = 2.25 * WALL PRESSURE
WIND FORCES AT EACH STORY (ASDI
PSF
PSF
(SEE WIND ANALYSIS PAGE)
18.79
12.53
PSF (ASD)
PSF (ASD)
DESG.
PARAPET
WIND (PSF)
PARAPET
HEIGHT
INT. WALL
WIND(PSF)
END WALL
WIND(PSF)
WALL TRIB.
HEIGHT
WIND(PLF)
WIND(PLF)
WIND
UPWARD (PSF)
INT. ZONE
END ZONE
ROOF
28.188
5
12.53
18.79
5.00
204
235
-20.14
UPPER FLOOR
12.53
18.79
10.00
125
188
MAIN FLOOR
12.53
18.79
10.00
125
188
SUITE 204 7795 128TI-1 STREET SURREY, B.C. V3W 4E6
Project Title:
Engineer:
Project ID:
Project Descr:
ASCE 7-10 Wind Forces Chpt 28, Pt2 & Chpt 30, Pt2 soft... pyright ENERCALC, INC. 1983-2018, Build: 10. 18.9.11
Description : BUILDING WIND ANALYSIS
Analytical Values Calculations per ASCE 7-10
V : Basic Wind Speed per Sect 26.5-1 A, B or C 11G.0 mph
Roof Slope Angle 0 to, 5 degrees
Occupancy per Table 1.5-1 11 All Buildings and other structures except
those listed as Category 1, 111, and IV
Exposure Category per 26.7
Exposure B
MRH : Mean Roof Height
33.0 ft
Lambda : per Figure 28.6-1, Page 305
1.05
Effective Wind Area of Component & Clad,
10.0 ftA 2
Roof pitch for cladding pressure
0 to 7 degrees
User specified minimum design pressure
10.0 psf
Topographic Factor Kzt per 26.8
1.00
LHD : Least Horizontal Dimension
ft
a = max (0.04 * LHD, 3, min(O.1 0 * LHD, 0.4*MRH))
3.00 ft
max (0.04 * LHD, 3, min(O.10 * LFID, 0.4*MRH))
Design Wind Pressures
Minimum Additional Load Case per 28.4.4 = 16 PSF on entire vertical plane
Horizontal Pressures ...
Zone: A = 20.16 psf
Zone: C =
16.00 psf
Zone: B = 10.00 psf
Zone: D =
10.00 psf
Vertical Pressures ...
Zone: E = -24.26 psf
Zone: G
-16.80 psf
Zone: F = -13.76 psf
Zone: H
-10.61 psf
Overhangs ...
Zone: Eoh -33.92 psf
Zone: Goh
-26.57 psf
Component & Cladding Design Wind
Pressures
Design Wind Pressure = Lambda Kzt * Ps30
per Eq 30.5-1
Roof Zone 1 Positive
10.000 risf
Minimum Additional Load Case per 28.4.4 16 PSF
Negative
-22.890 psf
on entire vertical plane
Roof Zone 2 Positive
10.000 psf
Negative
-38.325 psf
Roof Zone 3 Positive
10.000 psf
Negative
-57.750 psf
Wall Zone 4: Positive
22.890 psf
Negative
-24.780 psf
Wall Zone 5: Positive
22.890 psf
Negative
-30.555 psf
Roof Overhang Zone 2: -32.970 psf
Roof Overhang Zone 3: -54.180 psf
51
Project:
]SINGLE FAMILY DWELLING
Sheet 1
521
1
1
Location:
115712 - 72 AVE. WEST,EDMONDS WA
Job No.:
JUR801
I
I
Date:
131-Mar-19
By:
IKK
IChk:
JAB
ROOF FRAMING
SEISMIC FORCE (SF)
6.8 #/SQ FT.
(ASD)
LATERAL ANALYSIS (ALONG GRID #1 TO #7)
204 PLF
(INTERIOR ZONE)
235 PLF
(END ZONE)
SHEAR LINE
TRIB. WALL LENGTH FOR WIND FORCES ='B'ft
WIND SHEAR FORCE B*WF
TRIB. SEISMIC AREA 'A'SQ.FT=
SEISMIC SHEAR FORCE 'V'= A*SF
GOVERNING LOAD (W (wind) or E (Seismic)
ROOF DIAPH. LENGTH'L'-- FT.
ROOF DIAPH. SHEAR=V/L --- #/LF
USE ROOF DIAPH. FR1/Fl I
SHEAR WALL PANELS--+---+--
TOTALT= -------- FT
* SHEAR CAPACITY ADJUSTMENT FACTOR 'Co'
WALL SHEAR v = V/ (I * Co) (#/LF)
SHEAR PANEL USED(SEE SCHEDULE)
ANCHOR BOLT USE - 0
PENAL HIGHT 'Hl' FT.
SMALLEST PENAL LENGTH = 'L' FT
M.O.T. #FT
PANEL DL (ROOF+WALL) = 'W' #/FT
M.O.R = WL 2 /2 #FT
D.L. REACTION FROM HEADER ='R'
UPLIFT ON PANEL # �(MOT-0.6OxMOR)-R
STRAP WITH FLOOR BELOW
1
T-0
1644
194
1311
WIND
2 7. "
47.7
ROOF-1
0
�: 11)
�-- Z
>- 2
ca
u.j 0
.7i
Lu Lu
OE Lu
Lu LA
M Ln
0
ENDZONE
2
12.5
2936
1105
7489
SEISMIC
61
122.8
ROOF -I
3.5+3+5.5
12
1
624.1
12
N.A.
9.0
3
16849.48
135.0
607.5
1640.0
3855.0
MST60
3
1985
443
2999
SEISMIC
92.8
32.3
ROOF -I
4+4.75
8.75
1
342.7
10
N.A.
9.0
4
12338.13
�35 -0
1080.0
0.0
2922.5
CS16
INTERIOR ZONE
4
5
8.3
5.3
1680
1069
289
778
1955
5273
SEISMIC
SEISMIC
92.8
96.8
21.1
54.5
ROOF -I
ROOF-1
9.5+3.5
14
13
14
1
1
150.4
376.6
9
10
N.A.
N.A.
9.0
9.0
3.5
14
4737.56
47453.01
351.0
135.0
2149.9
13230.0
0.0
0.0
985.0
2822.5
CS16
CS16
ENDZONE
616.1
7
4.3
3.0
998
705
359
357
2433
2416
SEISMIC
SEISMIC.
11.5
11.5
211.6
210.1
ROOF-1
ROOF-1
11.5+17.5
9.25+0
29
9.25
1
1
. 83.9
261.2
9
9
N.A.
N.A.
9.0
9.0
11.5
9.25
8683.17
21744.21
181.0
181.0
11968.6
7749'4
0.0
0.0
130.6
1848.5
CS1 6
CS16 /'70q
'Co' SHEAR CAPACITY ADJUSTMENT FACTOR : ACCOUNTS FOR STRENGTH REDUCING EFFECT OF OPENING ON SHEAR WALL
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
MAINLAND ENGINEERING CORPORATION
Project:
SINGLE FAMILY DWELLING
ISheet
153
1
1
Location:
15712 - 72 AVE. WEST,EDMONDS WA
lJob No.:
JUR801
I
I
Date:
31-Mar-19
I By:
IKK
IChk:
JAB
ROOF FRAMING SEISMIC FORCE (SF) 6.8 #ISQ FT. (ASD)
LATERAL ANALYSIS (ALONG GIRD #ATO #G) WIND FORCE (WF) 204 PLF (INTERIOR ZONE)
235 PLF (END ZONE)
END ZONE
INTERIOR ZONE
END ZONE
SHEAR LINE
A/ A.1
B
C
D
G
TRIB. WALL LENGTH FOR WIND FORCES ='B'ft
11.3
17.8
13.5
29.5
22.5
WIND SHEAR FORCE B*WF
2643
3614
2748
6006
5285
TRIB. SEISMIC AREA 'A'SQ.FT=
890
591
454
1178
q?4
SEISMIC SHEAR FORCE 'V'= A*SF
6032
4002
3077
7980
6262
GOVERNING LOAD (W (wind) or E (Seismic)
SEISMIC
SEISMIC
SEISMIC
SEISMIC
SEISMIC
ROOF DIAPH. LENGTH'L'-- FT.
34.25
34.25
36.5
35.5
44.5
ROOF DIAPH. SHEAR=V/L --- #/LF
176.1
116.8
84.3
224.8
140.7
USE ROOF DIAPH. FR1/Fl
ROOF-1
ROOF-1
ROOF-1
ROOF-2
ROOF-1
SHEAR WALL PANELS--+---+--
8,5
13�5
12.5+8.25
8.75
17+10
TOTALT= -------- FT
8.5
13.5
20.75
8.75
27
* SHEAR CAPACITY ADJUSTMENT FACTOR 'Co'
1
1
1
1
1
WALL SHEAR v = W (I * Co) (#/LF)
709.6
296.4
148.3
912.0
231.9
SHEAR PANEL USED(SEE SCHEDULE) Z�,
12
9
9
13
9
ANCHOR BOLT USE u
N.A.
N.A.
N.A.
N.A.
N.A.
PENAL HIGHT 'Hl' FT.
9.0
9.0
9.0
9.0
e.0
SMALLEST PENAL LENGTH = 'L' FT
8.5
13.5
8.25
8.75
10
M.O.T. #FT
54284.29
36016.71
11009.71
71819.95
20873.36
PANELDL(ROOF+WALL) = 'W' #/FT
297.0
350.0
245.0
526.0
181.0
M.O.R = WL 2 /2 #FT
10729.1
31893.8
8337.7
20135.9
9050.0
D.L. REACTION FROM HEADER ='R'
825.0
0.0
0.0
0.0
0.0
UPLIFT ON PANEL # �(MOT-0.6OxMOR)-R
4804.0
1250.4
728.1
6827.2
1544.3
,STRAP WITH FLOOR BELOW
MST60
CS16
CS16
CMST12
CS16
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
MAINLAND ENGINEERING CORPORATION
Project:
ISINGLE FAMILY DWELLING
Sheet
54
Location:
115712 - 72 AVE. WEST,EDMONDS WA
Job No.:
UR801
Date:
131-Mar-19
By:
KK
Chk:
AB
UPPER FLOOR FRAMING SEISMIC FORCE (SF) 5.0 #/SQ FT. (ASID)
LATERAL ANALYSIS (ALONG GRID #1 TO #7) WIND FORCE (WF) 125 PLF (INTERIOR ZONE)
188 PLF (END ZONE)
END ZONE
INTERIOR ZONE
END ZONE
SHEAR LINE for level above
1
2
3
4
5
6/6.1
7
SHEAR FROM ROOF @ LINE 'Vr'
1644
7489
2999
1955
5273
2433
2416
SHEAR LINE AT THIS LEVEL
1
2
3
4
5
6/6.1
7
TRIB. WALLLENGTH FOR WIND FORCES ='B'ft
7.0
12.5
9.8
8.3
5.3
15.8
15.8
WIND SHEAR FORCE(THIS LEVEL) = B�WF
1315
2349
1832
1034
65
2960
2960
1
TRIB. SEISMIC AREA = 'A'SQ.FT�
1195
1486
443
1289
1778
359
1357
SEISMIC SHEAR FORCE(THIS LEVEL) 'V' = A -SF
978
2437
2219
j 1447
3902
1800
1788
GOVERNING LOAD (W (wind) or E (Seismic)
WIND
SEISMIC
SEISMIC
SEISMIC
SEISMIC
WIND
WIND
TOTAL SHEAR FORCE AT THIS LEVEL'V'-=
2960
9926
5218
3402
9174
5393
5376
FLOOR DIAPH. LENGTH'L'-- FT.
27.5
61
92.8
92.8
96.8
11.5
11.5
FLOOR DIAPH. SHEAR=V/L --- #/LF
47.8
40.0
23.9
15.6
.40.3
257.4
257.4
USE ROOF/ FLOOR DIAPH. 1R1/F1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-2
FLOOR-2
SHEAR WALL PANELS--+---+--
co
Lu 0
Ln U
7 _j
Lu
ui w
= F_
Lu V)
00 Ln
C) Ln
3.75+3,5
6
3.5+4.25+5.75
6.5+3.25
11.5+28
12:00:00
TOTALT= -------- FT
7.25
6
113,5
9.75
34
34
* SHEAR CAPACITY ADJUSTMENT FACTOR 'Co'
1
1
1
1
1
1
WALL SHEAR v = V/ (I * Co) (#/LF)
1369.1
869.7
252.0
941.0
158.6
158.1
SHEAR PANEL USED(SEE SCHEDULE) ILI
12 Both Side
13
9
13
9
9
ANCHOR BOLT USE
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
PENAL HIGHT 'H1' FT.
10.0
1 0�0
10.0
10.0
10.0
10.0
SMALLEST PENAL LENGTH 'L' FT
3.5
6
3.5
3.25
11.5
22.5
M.O.T. #FT
47918.7
52180.5
8820.1
30581.1
18240.0
35574.9
PANEL DL (ROOF+FLOOR+WALL) = 'W' #/FT
710.0
250.0
594.0
378.0
667.0
667.0
2/2
M.O.R = WL #FT
4348.8
4500.0
3638.3
1996.3
44105.4
168834.4
D.L. REACTION FROM HEADER ='R'
0.0 io.0
'0.0
'0.0
0.0
0.0
UPLIFT ON PANEL # {(MOT-0.6OxMOR)-R
12945.6 1
8246.8 --1182L3
-715.1
-2921.1
STRAP WITH FLOOR BELOW
IHD12
IGMST12
ICS16
___j9041.0
ICMST12
NOT REQ.
NOT REQ.
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
MAINLAND ENGINEERING CORPORATION
Project:
ISINGLE FAMILY DWELLING
ISheet
155
1 ----------- ----F
Location:
115712 - 72 AVE. WEST,EDMONDS WA
jJob No.:
JUR801
I
Date:
131-Mar-19
I By:
IKK
IChk:
JAB
UPPER FLOOR FRAMING SEISMIC FORCE (SF) 5.0 #/SQ FT. (ASD)
LATERAL ANALYSIS (ALONG GIRD #ATO #G) WIND FORCE (WF) 125 PLF (INTERIOR ZONE)
188 PLF (END ZONE)
ENDZONE
INTERIOR ZONE
END ZONE
SHEAR LINE for level above
A / A.1
B
C
D
G
SHEAR FROM ROOF @ LINE 'Vr'
6032
4002
3077
7980
6262
SHEAR LINE AT THIS LEVEL
A / A.1
B
C
D
G
TRIB. WALL LENGTH FOR WIND FORCES ='B'ft
11.3
17.8
13.5
29.5
22.5
WIND SHEAR FORCE(THIS LEVEL) = B-WF
2114
2224
1691
13696
4228
TRIB. SEISMIC AREA = 'A'SQ.FT=
1311
472
261
11068
969
SEISMIC SHEAR FORCE(THIS LEVEL) 'V' A -SF
1557
2365
1306
5356
4857
GOVERNING LOAD (W (wind) or E (Seismic)
WIND
SEISMIC
WIND
SEISMIC
SEISMIC
TOTAL SHEAR FORCE AT THIS LEVEL'V'-=
8146
16366
4768
13336
11119
FLOOR DIAPH. LENGTH'L'-- FT.
34.25
34.25
36.5
35.5
44.5
FLOOR DIAPH. SHEAR=V/L --- 9/1-17
61.7
69.0
46.3
150.9
109.1
USE ROOF/ FLOOR DIAPH. IRJ/ 1 1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
SHEAR WALL PANELS--+---+--
6.5
5.5+7.5
7.5+12
8.75
21+5
TOTALT= -------- FT
6.5
13
19.5
8.75
26
* SHEAR CAPACITY ADJUSTMENT FACTOR 'Co'
1
1
1
1
1
WALLSHEAR v = V/(I*Co) (#/LF)
1253,2
489.7
244.5
1524.1
427.7
SHEAR PANEL USED(SEE SCHEDULE) A
12 Both Side
11
9
12 Both Side
10
ANCHOR BOLT USE C-)
N.A.
N.A.
N.A.
N.A.
N.A.
PENAL HIGHT 'H1' FT.
10.0
10.0
10.0
10.0
10.0
SMALLEST PENAL LENGTH = 'L' FT
6.5
5.5
7.5
8.75
5
M.O.T. #FT
81456.9
26935.2
18338.7
133361.7
21383.0
PANEL DL (ROOF+FLOOR+WALL) = 'W' #/FT
769.5
822.5
300.0
998.5
653.5
M.O.R = WI-2/2 #FT
16255.7
12440.3
8437.5
38223.8
8168.8
D.L. REACTION FROM HEADER ='R'
0.0
0.0
0.0
0.0
0.0
UPLIFT ON PANEL # f(MOT-0.6OxMOR)-R
11031.3
3540.2
1770.2
12620.3
3296.4
STRAP WITH FLOOR BELOW 12-CMST12
jHD51B
ICS16
12-CMST12
HD513
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
MAINLAND ENGINEERING CORPORATION
Project:
[SINGLE FAMILY DWELLING
IS-heet -T---
561
1
Location:
15712 - 72 AVE. WEST,EDMONDS WA
I
1job No.:
JUR801
I
I
Date:
131-Mar-19
I By:
I
IKK
IChk:
JAE3
MAIN FLOOR FFLAMING SEISMIC FORCE (SF) 2.3 #/SQ FT. (ASD)
LATERAL ANALYSIS (ALONG GRID #1 TO #7) WIND FORCE (WF) 125 PLF (INTERIOR ZONE)
188 PLF (END ZONE)
ENDZONE
INTERIOR ZONE
END ZONE
SHEAR LINE for level above
1
2
3
4
5
6/6.1
TOTAL SHEAR FROM ABOVE @ LINE 'Vr'
2960
9926
5218
3402
9174
5393
SHEAR LINE AT THIS LEVEL
1
2
3
4
5
6/6.1
TRIB. WALL LENGTH FOR WIND FORCES ='B'ft
7.0
12.5
9.8
8.3
5.3
15.8
WIND SHEAR FORCE(THIS LEVEL) = B�WF
1315
2349
1832
1034
658
1973
TRIB. SEISMIC AREA = 'A'SQ.FT=
353
654
925
1079
520
178
,SEISMIC SHEAR FORCE(THIS LEVEL) 'V'= A*SF
815
1511
2138
2494
1203
410
GOVERNING LOAD (W (wind) or E (Seismic)
WIND
WIND
SEISMIC
SEISMIC
SEISMIC
WIND
TOTAL SHEAR FORCE AT THIS LEVEL'V'-=
4275
12275
7356
5896
10377
7366
FLOOR DIAPH. LENGTH'L'-- FT.
27.5
61
92.8
92.8
96.8
11.5
FLOOR DIAPH. SHEAR=V/L --- #/LF
47.8
38.5
23.0
26.9
12.4
171.6
USE ROOF/ FLOOR DIAPH. 1R1/F1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
SHEAR WALL PANELS--+---+--
Z
cc 2i
0 -j
Lu 0
i-- u
Ln
Lu
Lu Lu
ccf P-
Lu V)
CO Ln
0
-j
z
0
u
>-
cc
0
�u
Ln
Lu
Cf
Lu
co
0
5.5+4,25+3.75
20+5
7
__j
TOTALT= -------- FT
13.5
25
7
-j
<
SHEAR CAPACITY ADJUSTMENT FACTOR 'Co'
1
1
1
WALL SHEAR v = V/ (I * Co) (#/LF)
544.9
235.8
1482.4
Z
0
SHEAR PANEL USED(SEE SCHEDULE)
11
9
13 Both Side
u
ANCHOR BOLT USE 0
2
1
I 5
>- -
PENAL HIGHT 'H1' FT.
8.0
80
8.0
LLJ
1--
SMALLEST PENAL LENGTH 'L; FT
3.75
5
7
�n-
M.O.T. #FT
16346.8
9434.0
83015.3
Lu
PANEL DL (ROOF+ FLOOR+WALL) = 'W' #/FT
412.0
756.0
621.0
- Lu
M.O.R = WL2/2 #FT
2896.9
9450.0
15214.5
0
D.L. REACTION FROM HEADER ='R'
0.0
0.0
0.0
UPLIFT ON PANEL # �(MOT-0.6OxMOR)-R
3895.7
752.8
10555.2
STRAP WITH FLOOR BELOW
HD7B
HD513
HD12
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
MAINLAND ENGINEERING CORPORATION
Project:
SING E FAMILY DWELLING
ISheet --
157
1
11
Location:
15712 - 72 AVE. WEST,EDMONDS WA
lJob No.:
JURB01
I -F-
,
Date:
03-Apr-19
I By:
IKK
IChk:
JAB
MAIN FLOOR FRAMING SEISMIC FORCE (SF) 2.3 #/SO FT. (ASID)
LATERAL ANALYSIS (ALONG GIRD #ATO #G) WIND FORCE (WF) 125 PLF (INTERIOR ZONE)
188 PLF (END ZONE)
END ZONE
INTERIOR ZONE
ENDZONE
SHEAR LINE for level above
A / A.1
B
C
D
TOTAL SHEAR FROM ABOVE @ LINE 'Vr'
8146
6366
4768
_
13336
11119
rG
SHEAR LINE AT THIS LEVEL
A/A.1
B
C-
D
TRIB. WALL LENGTH FOR WIND FORCES ='B'ft
11.3
17.8
13.5
29.5
22.5
WIND SHEAR FORCE(THIS LEVEL) = B�WF
2114
2224
2537
5544
4228
1
.TRIB. SEISMIC AREA = 'A'SQ.FT=
403
594
451
1317
1057
ISEISMIC SHEAR FORCE(THIS 1-FVFI ) 'V'= A -SF
932
1373
11042
3045
2443
1
GOVERNING LOAD (W (wind) or E (Seismic)
WIND
WIND
WIND
WIND
WIND
TOTAL SHEAR FORCE AT THIS LEVEL'V'-=
10260
8590
7305
18880
15347
FLOOR DIAPH. LENGTH'L'-- FT.
34.25
34.25
36.5
35.5
44.5
FLOOR DIAPH. SHEAR=V/L --- #/LF
61.7
64,9
69.5
156.2
95.0
USE ROOF/ FLOOR DIAPH. lRl/Fl
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
SHEAR WALL PANELS--+---+--
0
0
z
0
CL
V)
>-
Cn
0
Ln
Ln
Lu
Lu
uj 2
<
4.5
12.5
15.25
TOTALT= -------- FT
11.5
12.5
15�25
<
SHEAR CAPACITY ADJUSTMENT FACTOR 'Co'
1
1
1
3:
WALLSHEAR v = V/(I*Co) (#/LF)
747.0
584.4
1238.0
z
SHEAR PANEL USED(SEE SCHEDULE)
1'�
12
12 Both Side
0
U
ANCHOR BOLT USE
3'
2
cc
PENAL HIGHT 'Hl' FT.
8.0
-4
8.0
8.0
0
Lu
SMALLEST PENAL LENGTH 'L' FT
4.5
12.5
15.25
V)
7)
M.O.T. #FT
26891,1
58439.9
151038.5
Lu
cc
PANEL DL(ROOF+FLOOR+WALL) = 'W' #/FT
1295.0
772.5
1471.0
Lu
co
M.O.R = WL2/2 #FT
13111.9
60351.6
171049.7
0
D.L. REACTION FROM HEADER ='R'
0.0
0.0
0.0
UPLIFT ON PANEL # {(MOT-0.60xMOEI�
4227.6 11778.3
13174.3
STRAP WITH FLOOR BELOW
HD7B jHD5B
jHD5B
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
57
MAINLAND ENGINEERING CORPORATION
Project:
SINGLE FAMILY DWELLING
Sheet
58
Location:
15712 - 72 AVE. WEST,EDMONDS WA
Job No.:
UR801
Date:
31-Mar-19
113y:
BS
Chk: is
MAX FRAMING / WALL LOAD AT CONC GRADE BEAM
F RAM I N GfWALL LOAD
ROOFLOAD
FLOOR LOAD
WALL -LOAD
FOOTING
(GRID LINES)
DL+LL
Max.
Span
CONC. WALL
STUD WALL
LOAD
HEIGHT
TOTAL
LBS/FT
SEE CAL
LL+DL
HEIGHT
DL+LL
Span
WALL 1 / 7'
43
28
100
10
74
28
12
30
4636
CF-2
4039.75
WALL A/G
43
20.75
100
10
74
20.75
12
51
JCF-2
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
58
MAINLAND ENGINEERING CORPORATION
APPENDIX - A
59
DOUGLAS FIR- LARCH FRAMING LUMBER
2" - 4" THICK
2" - 4" THICK
BEAMS &
POSTS &
2" & WIDER
2" & WIDER
STRINGERS
TIMBERS
GRADE#2
GRADE#1
GRADE#1
GRADE#1
(PSI)
(PSI)
(PSI)
(PSI)
Fb (SGL)
875
1000
1350
1200
Fb(REP)
1
1006
1000
Ft
575
675
675
825
Fv
95
95
85
85
Fc (PERP)
625
625
625
625
Fc(PAR)
1300
1450
925
1 cloo
E
116000001
1700000
1600000
1600000
SECTION PROPERTIES
SIZE
b
d
A
Cf
S
CFS
I
WEIGHT
(IN)
(IN)
(IN 2)
(IN')
(IN)
(IN 4)
(PSF)
2x4
1.50
3.50
5.25
1.500
3.06
4.59
5.36
1.28
2x6
1.50
5.50
8.25
1,300
7.56
9.83
20.80
2,01
2x8
1.50
7.25
10.88
1,200
13.14
15.77
47.63
2.64
2x10
1.50
9.25
13.88
1,100
2 1.39
23.53
98.93
3.37
2x12
1.50
11.25
16.88
1,000
31.64
31.64
177.98
4.10
2x14
1.50
13.25
19.88
0.900
43.89
39.50
290.78
4.83
4x4
3.50
3.50
12.25
1.500
7.15
10.72
.12.51
2.98
4x6
3.50
5.50
19.25
1.300
17.65
22.94
48.53
4.68
4x8
3.50
7.25
25.38
1.200
30.66
36,79
111.15
6.17
4x10
3.50
9.25
32.38
1.100
49.91
54.90
230.84
7.87
4 x 12
3.50
11.25
39.38
1.000
73.83
73.83
415.28
9.57
4x14
3.50
13.50
47.25
0.900
106.31
95.68
717.61
11.48
6x6
5.50
5.50
30.25
1.000
27.73
27.73
76.26
7.35
6 x 8
5.50
7.50
41.25
1.000
51.56
51.56
1'93.36
10.03
6x10
5.50
9.50
52.25
1.000
82.73
82.73
392.96
12.70
6 x 12
5.5o
11.50
63.25
1.000
121.23
121.23
697.07
15.37
6x14
5.50
13.50
74.25
0.987
167.06
164.89
1127.67
18.05
8x8
7.50
7.50
56,25
1.000
70.31
70�31
263.67
13.67
8x10
7.50
9.50
71.25
1.000
112.81
112.81
535.86
17.32
8 x 12
7.50
11.50
86.25
1.000
165.31
165.31
950.55
20.96
8x14
7.50
13.50
1 0
101.25
0.987
227.81
, 224.85
1537.7
24.61
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
59
MAINLAND ENGINEERING CORPORATION
APPENDIX -13
60
SHEAR WALL SCHEDULE PER 2015 IBC
FRAMING NOTES: -
A)
ALL EXTERIOR WALL TO BE SECURED WITH 1/2" DIA.xl2" ANCHOR BOLTS AT 64" O.C.
UNLESS NOTED OTHERWISE.
B)
AN ALTERNATE TO ANCHOR BOLTS USE PHILLIPS RED HEAD SCREWS
C)
ALL INTERIOR WALLS TO BE ANCHORED WITH SHOT PINS (RAMSET # 3348 OR EQUIV.)
AT 36" O.C. AT BEARING WALLS AND 48" 0.. AT NON BEARING
D)
WHERE PANELS ARE APPLIED ON BOTH FACES OF WALL AND NAIL SPACING IS LESS
6 INCHES ON CENTER ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON
DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3 INCHES NOMINAL OR THICKER
AND NAILS ON EACH SIDE SHALL BE STAGGERED.
E)
A MINIMUM OF 1/2" EDGE DISTANCE IS REQUIRED FOR NAILING AT THE 3x BOUNDARY
AND PANEL EDGE MEMBERS OF THE SHEAR WALL UNLESS OTHERWISE NOTED.
MARK
SHEAR (EQ)
SHEAR (WIND)
PLATE TO BLKG..
A
IDESCRIPTION
#/FT.
#/FT.
NAILING REQ..
9
15/32" STRUCTURAL I PLYWOOD WITH 8d NAILS @ 6" O.C. AT
280
307
16d @ 5" O.C.
EDGES & 12" O.C. FIELD (TABLE 4.3A 2015 SDPWS) W/2x FRAMING *
OR A35 @ 20" O.C.
10
15132" STRUCTURAL I PLYWOOD WITH 8d NAILS @ 4" O.C. AT
430
447
16d @ 3-1/2" O.C.
EDGES & 12" O.C. FIELD (TABLE 4.3A 2015 SDPWS) W/2x FRAMING *
OR A35 @ 12" O.C.
11
15/32" STRUCTURAL I PLYWOOD WITH 8d NAILS @ 3" O.C. AT
550
575
16d @ Y O.C.
EDGES & 12" O.C. FIELD (TABLE 4.3A 2015 SDPWS) W/2x FRAMING *
OR A35 @ 10" O.Cm
12
15132" STRUCTURAL I PLYWOOD WITH 10d NAILS @ 3" O.C. AT
665
840
A35 @ 7" O.C.
EDGES & 12" O.C. FIELD (TABLE 4.3A 2015 SDPWS) W/2x FRAMING **
13
1/2" STRUCTURAL I PLYWOOD WITH 10d NAILS @ 2" O.C. AT
870
1077
A35 @ 7" O.C.
EDGES & 12" O.C. FIELD (TABLE 4.3A 2015 SDPWSC) W/2x FRAMING
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
60
MAINLAND ENGINEERING CORPORATION
I APPENDIX - C 1 611
ANCHOR BOLT SCHEDULE
MARK
DESCRIPTION
SHEAR
0
PER ANSI/AWC NDS 2015 TABLE 12E
-#/FT.
1
5/8" DlA. x 12" ANCHOR BOLTS @ 48" O/C IN 2 x PLATE *
372
2
5/8" DIA. x 12" ANCHOR BOLTS @ 32" O/C IN 2 x PLATE *
558
3
5/8" DIA. x 12" ANCHOR BOLTS @ 24" O/C IN 2 x PLATE
744
4
5/8" DIA x 12" ANCHOR BOLTS @ 16" O/C IN 2 x PLATE
1119
ROOF / FLOOR DIAPHRAGM SCHEDULE
MARK
DESCRIPTION
SHEAR
=
PER TABLE4.2A/4.2C 2015SDPWS (AF&PA)
#/FT.
ROOF-1
15132" STRUCTURAL I UNBLOCKED W/10d" NAILS @ 6", 6", &
215
12" OIC AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
ALL CASES
ROOF-2
15/32" STRUCTURAL I UNBLOCKED W/1 Od" NAILS @ 6", 6", &
285
10" O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
CASE 1
ROOF-3
15/32" STRUCTURAL I BLOCKED W/1 Od" NAILS @ 4", 6", &
425
10"01C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
ROOF-4
15/32" STRUCTURAL I BLOCKED W/10d— NAILS @ 2.5",4", &
575
10" OIC AT BOUNDARY, EDGEAND FIELD RESPECTIVELY
ROOF-5
15132" STRUCTURAL I BLOCKED W/1 Od— NAILS @ 2". 3", & 10' O/C AT
730
BOUNDARY, EDGE AND FIELD RESPECTIVELY
FLOOR-1
19/32" CDX PLYWOOD UNBLOCKED W/10d** NAILS @ 6", 6", &
215
112" O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
ALL CASES
FLOOR-2
19/32"CDX PLYWOOD UNBLOCKED W/10d— NAILS @ 6",6", &
285
12- O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
CASE 1
FLOOR-3
19132" CDX PLYWOOD BLOCKED W/1 Od" NAILS @ 4", 6", &
425
10" O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
Note : * Sill plate is anchored by two times the required number of bolts per table 1911.2
Framing at adjoining panel edges shall be 3 inches nominal or wider and nails
shall be staggered where both of the following conditions are met:
1. 10d nails having penetration into framing of more than 1-1/2 inches and
2. Nails are spaced 3 inches o/c or less.
SUITE 204 7795 128TH STREET SURREY, B.C. V3W 4E6
61
MAINLAND ENGINEERING CORPORATION
I APPENDIX - D 1 621
ALLOWABLE LOADS
SOIL BEARING CAPACITY 3000 PSF PER SOIL REPORT BY
GEOTECH CONSULTANTS, INC.
2401 10TH AVE. E SEATTLE, WASHINGTON 98102
PROJECT NO.- JN 18021
DATED- JANUARY 25, 2018
PHONE NO.- (425) 747-5618
A. CONTINUOUS FOOTINGS
FOR 18" DEEP CONTINUOUS FOOTINGS
NET SOIL BEARING 2,775 PLIF
CF-1 18" WIDE x 18" DEEP W/ 1 #4 AT TOP & 244 AT BOTTOM
W/ #4 TRANSVERSE REBARS @ 24" O.0
CAPACITY = 2775 X 1.5 4,163 PLF
CF-2 24" WIDE x 18" DEEP W/ 1 #4 AT TOP & 344 AT BOTTOM
W/ #4 TRANSVERSE REBARS @ 24" O.0
CAPACITY = 2,775 x 2.0 5,550 PLEF
CF-3 36" WIDE x 18" DEEP W/ 2 #5 AT TOP & 345 AT BOTTOM
W/#4 TRANSVERSE REBARS @16"O.0
CAPACITY = 2,775 2.25 6,244 PLF
B. ISOLATED PAD FOOTINGS
F-I T-O" xT-0" SQ. X 18" DEEP W/ -4 #5 REBAR AT BOTTOM EA. WAY
CAPACITY = 2,775 x 3 2 24,975 #
F-2 4'-0" x4'-O" SQ. X 18" DEEP W/ -5 #5 REBAR AT BOTTOM EA. WAY
CAPACITY = 2,775 x 4 .02 44,400 #
F-3 5'-0" x5'-O" SQ. X 18" DEEP W/ -7 #5 REBAR AT BOTTOM EA. WAY
CAPACITY = 2,775 x 5 .02 69,375 #
SUITE 204 7795 128TF-I STREET SURREY, B.C. V3W 4E6
62
MAINLAND ENG114EERING CORPORATION
APPENDIX - E
63
TOP SPLICE SCHEDULE
MARK
16d NAILS
3/4 BOLTS
LOAD PER
REMARKS
E.S
E.S
A
8
1140
SEE SP-1
B
12
1710
SEE SP-1
c
16
-
2280
SEE SIP-1
D
-
2
4140
SEE SP-2
E
-
3
6200
SEE SP-2
SEE SP-2
IF
-
4
8250
G
-
5
11800
SEE SP-2
H
-
6
14160
SEE SP-2
SUITE 204 7795 128TI-I STREET SURREY, B.C. V3W 4E6
63
RetainPro(c)1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: BC 2018ACI 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Criteria
Soil Data
Retained Height
4.00 ft
Allow Soil Bearing 3,000.0 psf
Wall height above soil
0.50 ft
Equivalent Fluid Pressure Method
Active Heel Pressure 35.0 psf/ft
Slope Behind Wall
0.00
Height of Soil over Toe
8.00 in
Water heiQht over heel
0.0 ft
Passive Pressure 0.0 psf/ft
Surcharge Loads
Surcharge Over Heel 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe 0.0
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load 0.0 lbs
Axial Live Load 0.0 lbs
Axial Load Eccentricity 0.0 in
Earth Pressure Seismic
Method : Uniform
Multiplier Used 8.000
(Multiplier used on soil density)
Design Summary
Wall Stability Ratios
Overturning 3.93 OK
Sliding 1.71 OK
Total Bearing Load 1,841 lbs
... resultant ecc. 2.40 in
Soil Pressure @ Toe
706 psf OK
Soil Pressure @ Heel
346 psf OK
Allowable
3,000 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe
989 psf
ACI Factored @ Heel
484 psf
Footing Shear @ Toe
3.2 psi OK
Footing Shear @ Hee
3.0 psi OK
Allowable
90.0 psi
Sliding CaIcs
Lateral Sliding Force
539.6 lbs
less 0 %Passive Force
0.0 lbs
less 100% Friction Force
920.4 lbs
Added Force Req'd
o.o lbs OK
.... for 1.5 Stability
0.0 lbs OK
Soil Density, Heel
130.00, pcf
Soil Density, Toe
0.00 pcf
FootingIlSoil Friction
0.500
Soil height to ignore
for passive pressure
0.00 in
d Applied to Stem
Lateral Load
0.0 #Ift
... Height to Top
0.00 ft
... Height to Bottom
0.00 ft
Load Type
Dead Load (D)
(Service Level)
Wind on Exposed Stem
0.0 psf
(Service Level)
Uniform Seismic Force = 38�667
Total Seismic Force = 186.889
Stem Construction
11
Design Height Above Ftc
ft
Wall Material Above "Ht"
Design Method
Thickness
Rebar Size
Rebar Spacing
Rebar Placed at
Design Data
fb/FB + fa/Fa
Total Force @ Section
Service Level
lbs
Strength Level
lbs
Moment .... Actual
Service Level
ft-#
Strength Level
ft-#
Vertical component of active lateral soil pressure IS
considered in the calculation of soil bearing pressures.
Load Factors -
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
IBC 2018,ACI
1.200
1.600
1.600
1.000
1.000
Moment ..... Allowable
Shear ..... Actual
Service Level
Strength Level
Shear ..... Allowable
Anet (Masonry)
Rebar Depth 'd'
Masonry Data
fm
Fs
Solid Grouting
Modular Ratio'n'
Wall Weight
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
Concrete Data
fc
Fy
Bottom
[Adjacent Footing Load
Adjacent Footing Load
0.0 lbs
Footing Width
0.00 ft
Eccentricity
0.00 in
Wall to Ftg CL Dist
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall
0.0 ft
Poisson's Ratio
0.300
Stem OK
0.00
Concrete
LRFD
8.00
# 5
16.00
Edge
0.145
602.7
906.7
6,274�3
psi =
psi = 8.1
psi = 90.0
in2 =
in = 6.19
psi =
psi =
psf 100.0
= ASD
psi = 3,600.0
psi = 60,000.0
M-11
RetainPro(c)1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: BC , 2018,ACI 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Concrete Stem Rebar Area Details
Bottom Stem
Vertical Reinforcing
Horizontal Reinforcing
As (based on applied moment):
0.0343 in2/ft
(4/3) * As :
0.0458 in2/ft
Min Stem T&S Reinf Area 0.864 in2
200bd/fy: 200(12)(6.1875)/60000
0.2475 in2/ft
Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft
0.0018bh : 0.0018(12)(8):
0.1728 in2/ft
Horizontal Reinforcing Options:
One layer of: Two layers of
Required Area
0. 1728 in2/ft
#4@ 12.50 in #4@ 25.00 in
Provided Area
0.2325 in2/ft
#5@ 19.38 in #5@ 38.75 in
Maximum Area:
1.207 in2[ft
#6@ 27.50 in #60 55.00 in
Footing Dimensions & Strengths
Toe Width
1.00 ft
Heel Width
2.50
Total Footing Width
3.50
Footing Thickness
10.00 in
Key Width 0.00 in
Key Depth 0.00 in
Key Distance from Toe 0.00 ft
fc = 3,600 psi Fy = 60,000 psi
Footing Concrete Densit� 150.00 pcf
Min. As % 0.0020
Cover @ Top 1.50 @ Btm.= 3.00 in
Footing Design Results
Toe
Heel
Factored Pressure 989
484 psf
Mu': Upward 470
962 ft-#
Mu': Downward 127
1,301 ft-#
Mu: Design 343
339 ft-#
Actual 1 -Way Shear 3.18
3.01 psi
Allow 1 -Way Shear 48.00
48.00 psi
Toe Reinforcing = # 5 @ 12.00 in
Heel Reinforcing = # 5 @ 16.00 in
Key Reinforcing = None Spec'd
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm
Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm
Key: No key defined
Min footing T&S reinf Area 0.76 in2
Min footing T&S reinf Area per foot 0.22 ln2 ift
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 11.11 in #4@ 22.22 in
#5@ 17.22 in #5@ 34.44 in
#6@ 24.44 in #6@ 48.89 in
Summa of Overturning & Resisting Forces & Moments
..... OVERTURNING ... ..... RESISTING...
Force Distance -6ment Force Distance- Moment
Item lbs ft ft_# lbs ft ft_#
Heel Active Pressure
Surcharge over Heel
Surcharge Over Toe
Adjacent Footing Load
Added Lateral Load
Load @ Stem Above Soil
Seismic Earth Load
408.8 1.61
130.8 2.42
Total 539.6 O.T.M.
Res isti ng/Overturning Ratio - 3.93
Vertical Loads used for Soil Pressure 1,840.8 lbs
658.7 Soil Over Heel
Sloped Soil Over Hee
Surcharge Over Heel
Adjacent Footing Load
Axia I Dead Load on Stem=
Axial Live Load on Stem
316.2 Soil Over Toe
Surcharge Over Toe
974.8 Stem Weight(s)
Earth @ Stem Transitions=
Footing Weigh -
Key Weight
Vert. Component
If seismic is included, the OTM and sliding ratios
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201
Vertical component of active lateral soil pressure IS considered in the
calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS considered in the
calculation of Overturning Resistance.
953.3 2.58 2,462.8
0.50
450.0 1.33 600.0
437.5 1.75 765.6
3.50
Tota I = 1,&40.8 lbs R.M.= 3,828.4
Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
65
RetainPro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018ACI 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Tilt I
Horizontal Deflection at Tor) of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 250.0 pci
Horizontal Defi @ Top of Wall (approximate only) 0.025 in
The above calculation is not valid if the heel soil bearing r)ressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
RetainPro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Criteria
Retained Height
6.00 ft
Wall height above soil
0.50 ft
Slope Behind Wall
0.00
Height of Soil over Toe
8.00 in
Water height over heel
0.0 ft
Surcharge Loads
Surcharge Over Heel 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe 0.0
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load 00 lbs
Axial Live Load 0-0 lbs
Axial Load Eccentricity 0.0 in
Earth Pressure Seismic Load
Method : Uniform
Multiplier Used 8.000
(Multiplier used on soil density)
Design Summary
Wall Stability Ratios
Overturning 3.63 OK
Sliding 1.69 OK
Total Bearing Load 3,649 lbs
... resultant ecc. 4.70 in
Soil Pressure @ Toe
1,148 psf OK
Soil Pressure @ Heel
389 psf OK
Allowable
3,000 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe
1,607 psf
ACI Factored @ Heel
544 psf
Footing Shear @ Toe
6.0 psi OK
Footing Shear @ Hee
6.3 psi OK
Allowable
90.0 psi
Sliding Cales
Lateral Sliding Force
1,078.6 lbs
less 0 %Passive Force = -
0.0 lbs
less 100% Friction Force = -
1,824.4 lbs
Added Force Req'd
0.0 lbs OK
.... for 1.5 Stability
0.0 lbs OK
Soil Data �J
Allow Soil Bearing 3,000.0 psf
Equivalent Fluid Pressure Method
Active Heel Pressure 35.0 psf/ft
Passive Pressure
0.0 psf/ft
Soil Density, Heel
130.00 pcf
Soil Density, Toe
0.00 pcf
FootingIlSoil Friction
0.500
Soil height to ignore
for passive pressure
0.00 in
Lateral Load Applied to Stem
Lateral Load
0.0 #/ft
... Height to Top
0.00 ft
... Height to Bottom
0.00 ft
Load Type
Dead Load (D)
(Service Level)
Wind on Exposed Stem
0.0 psf
(Service Level)
Uniform Seismic Force = 54�667
Total Seismic Force = 373.556
Stem Construction
I
Design Height Above FtE
ft=
Wall Material Above "Ht"
Design Method
Thickness
Rebar Size
Rebar Spacing
Rebar Placed at
Design Data
fb1FB + fa/Fa
Total Force @ Section
Service Level
lbs =
Strength Level
lbs =
Moment .... Actual
Service Level
ft-# =
Strength Level
ft-# =
Moment ..... Allowable
Shear... -Actual
Service Level
psi =
Strength Level
psi =
Shear ..... Allowable
psi =
Anet (Masonry)
in2 =
Rebar Depth 'd'
in=
Masonry Data
fm
psi =
Fs
psi =
Solid Grouting
Vertical component of active lateral soil pressure IS Modular Ratio'n'
considered in the calculation of soil bearing pressures. XA1,11 ; k+
Load Factors -
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
IBC 2018,ACI
1.200
1.600
1.600
1.000
1.000
. U F.
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Bottom
Code: BC 2018ACI 318-14JIMS 402-16
Adjacent Footing Load
Adjacent Footing Load
0.0 lbs
Footing Width
0.00 ft
Eccentricity
0.00 in
Wall to Ftg CL Dist
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall
0.0 ft
Poisson's Ratio
0.300
Stem OK
0.00
Concrete
LRFD
8.00
# 5
112�00
Edge
0.362
1,33&0
3,000.0
8,277�2
18.0
90.0
6.19
100.0
Masonry Design Method = ASD
Concrete Data
fc psi =
Fy psi =
3,600.0
60,000.0
67
RetainPro (c) 1987-2018, Build 11.18.06.30
License: KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Concrete Stem Rebar Area Details
Bottom Stem
Vertical Reinforcing
Horizontal Reinforcing
As (based on applied moment):
0.1136 in2/ft
(4/3) * As :
0.1515 in2/ft
Min Stem T&S Reinf Area 1,248 1n2
200bd/fy: 200(12)(6.1875)/60000
0.2475 in2/ft
Min Stem T&S Reinf Area per ft of stem Height: 0.192 in2/ft
0.0018bh : 0.0018(12)(8):
0.1728 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of
Required Area
0.1728 in2/ft
#4@ 12.50 in #4@ 25.00 in
Provided Area
0.31 in2/ft
#5@ 19.38 in #5@ 38.75 in
Maximum Area
1.207 in2tft
#6@ 27.50 in #6@ 55.00 in
Footing Dimensions & Strengths
F_�_ooting Design Results
I
Toe Width T
M
1,00 ft
Toe
Heel
Heel Width
3.75
Factored Pressure
1,607
544 psf
Total Footing Width
4.75
Mu': Upward
766
3,679 ft-#
Footing Thickness
10.00 in
Mu': Downward
127
5,162 ft-#
Mu: Design
639
1,483 ft-#
Key Width
0.00 in
Actual 1 -Way Shear
= 6.05
6.33 psi
Key Depth
0.00 in
Allow 1 -Way Shear
= 48.00
48.00 psi
Key Distance from Toe
0.00 ft
T P.i�fin
= ii r iRi it) nn in
fc = 3,600 psi Fy = 60,000 psi
Footing Concrete Densit� 150.00 pcf
Min. As % 0.0020
Cover @ Top 1.50 @ Btm.= 3.00 in
Heel Reinforcing = # 5 @ 16.00 in
Key Reinforcing = None Spec'd
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm
Heel: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm
Key: No key defined
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 11.11 in
#5@ 17.22 in
#6@ 24.44 in
1.03 in2
0.22 in2 ift
If two layers of horizontal bars:
#4@ 22.22 in
#5@ 34.44 in
#6@ 48.89 in
Summary of Overturning & Resisting Forces & Moments
..... OVERTURNING .... �oment .....RESISTING .....
Force Distance Force Distance Moment
Item lbs ft ft-# lbs ft ft_#
Heel Active Pressure 817.2
2.28 1,861.3
Surcharge over Heel
Surcharge Over Toe
Adjacent Footing Load
Added Lateral Load
Load @ Stem Above Soil
Seismic Earth Load 261.5
3,42 893.4
Total 1,078.6
O.T.M. 2,754.7
Res isti ng/Overturning Ratio
3.63
Vertical Loads used for Soil Pressure
3,648.8 lbs
If seismic is included, the OTM and sliding ratios
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201
Vertical component of active lateral soil pressure IS considered in the
calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS considered in the
calculation of Overturning Resistance.
Soil Over Heel
2,405.0 3.21
7,716.0
Sloped Soil Over Hee
Surcharge Over Heel
Adjacent Footing Load
Axial Dead Load on Stern=
Axial Live Load on Stem
Soi I Over Toe
0.50
Surcharge Over Toe
Stem Weight(s)
650.0 1.33
866.7
Earth @ Stem Transitions
Footing Weigh-
&93.8 2.38
1,410.2
Key Weight
Vert. Component
4.75
Total
3,648.8 lbs R.M.=
9,992.9
Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
NO
RetainPro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018ACI 318-14JIMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Tilt I
.Horizontal Deflection at Ton of Wall due to Settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 2,50.0 pci
Horizontal Def] @ Top of Wall (approximate only) 0.044 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
W
RetainPro(c)1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018ACI 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Criteria
Soil Data
Retained Height
8.00 ft
Allow Soil Bearing 3,000.0 psf
Wall height above soil
0.50 ft
Equivalent Fluid Pressure Method
Active Heel Pressure 35.0 psf/ft
Slope Behind Wall
0.00
Height of Soil over Toe
8.00 in
Water heiaht over heel
0.0 ft
Passive Pressure 0.0 psf1ft
Surcharge Loads
Surcharge Over Heel 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe 0.0
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load 0.0 lbs
Axial Live Load 0.0 lbs
Axial Load Eccentricity 0.0 in
Earth Pressure Seismic
Method : Uniform
Multiplier Used 8.000
(Multiplier used on soil density)
Design Summary
Wall Stability Ratios
Overturning 3.99 OK
Sliding 1.71 OK
Total Bearing Load 6,169 lbs
... resultant ecc. 4.42 in
Soil Pressure @ Toe
1,272 psf OK
Soil Pressure @ Heel
626 psf OK
Allowable
3,000 pSf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe
1,781 psf
ACI Factored @ Heel
877 psf
Footing Shear @ Toe
14.2 psi OK
Footing Shear @ Hee
9.9 psi OK
Allowable
90.0 psi
Sliding Cales
Lateral Sliding Force
1,802.4 lbs
less 0 %Passive Force = -
0.0 lbs
less 100% Friction Force = -
3,084.6 lbs
Added Force Req'd
0.0 lbs OK
.... for 1.5 Stability
0.0 lbs OK
Soil Density, Heel
130.00 pcf
Soil Density, Toe
0.00 pcf
FootingIlSoil Friction
0.500
Soil height to ignore
for passive pressure
0.00 in
Lateral Load Applied to 3 ern
Lateral Load
0.0 #/ft
... Height to Top
0.00 ft
... Height to Bottom
0.00 ft
Load Type
Dead Load (D)
(Service Level)
Wind on Exposed Stem
0.0 psf
(Service Level)
Uniform Seismic Force = 70.667
Total Seismic Force = 624.222
Stem Construction
Design Height Above Ftc
ft=
Wall Material Above "Ht"
Design Method
Thickness
Rebar Size
Rebar Spacing
Rebar Placed at
Design Data
fb/FB + fa/Fa
Total Force @ Section
Service Level
lbs =
Strength Level
lbs =
Moment .... Actual
Service Level
ft-# =
Strength Level
ft-# =
Vertical component of active lateral soil pressure IS
considered in the calculation of soil bearing pressures
Load Factors -
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
IBC 2018,ACI
1.200
1.600
1.600
1.000
1.000
Moment ..... Allowable
Shear.....Actual
Service Level
Strength Level
Shear ..... Allowable
Anet (Masonry)
Rebar Depth 'd'
Masonry Data
fm
Fs
Solid Grouting
Modular Ratio'n'
Wall Weight
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
Concrete Data
fc
Fy
psi =
psi =
psi =
in2 =
in=
psi =
psi =
psf
Bottom
Adjacent, Footing Load
Adjacent Footing Load
0.0 lbs
Footing Width
0.00 ft
Eccentricity
0.00 in
Wall to Ftg CL Dist
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall
0.0 ft
Poisson's Ratio
0.300
Stem OK
0.00
Concrete
LRFD
8.00
# 5
10.00
Edge
0.715
2,357.3
7,040.0
9,847.6
31.7
90�0
6.19
100.0
= ASD
psi = 3,600.0
psi = 60,000.0
70
RetainPro (c) 1987-2018, Build 11.18.06.30
License ; KW-06060370 Cantilevered Retaining Wall Code: BC 2018ACI 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Concrete Stem Rebar Area Details
Bottom Stem
Vertical Reinforcing
Horizontal Reinforcing
As (based on applied moment):
0.2666 in2/ft
(4/3) * As :
0.3554 in2/ft
Min Stem T&S Reinf Area 1.632 in2
200bd/fy 200(12)(6.1875)/60000
0.2475 in2/ft
Min Stem T&S Reinf Area per ft of stern Height : 0.192 in2/ft
0.0018bh 0.0018(12)(8):
0.1728 in2/ft
Horizontal Reinforcing Options :
One layer of : Two layers of
Required Area
0.2666 in2/ft
#4@ 12.50 in #4@ 25.00 in
Provided Area
0.372 in2/ft
#5@ 19.38 in #5@ 38.75 in
Maximum Area:
1.207 in2/ft
#6 27.50 in #6 55.00 in
Footing Dimensions & Strengths
Toe Width
1.50 ft
Heel Width
5.00
Total Footing Width
6.50
Footing Thickness
10.00 in
Key Width
0.00 in
Key Depth
0.00 in
Key Distance from Toe
0.00 ft
fc = 3,600 psi Fy =
60,000 psi
Footing Concrete Densit�
150.00 pcf
Min. As %
0.0020
Cover @ Top 1.50 Btm.= 3.00 in
Footing Design Res�
Toe
Heel
Factored Pressure
1,781
877 psf
Mu': Upward
1,925
10, 119 ft-#
Mu': Downward
286
13,126 ft-#
Mu: Design
1,639
3,007 ft-#
Actual 1 -Way Shear
14.23
9.92 psi
Allow 1-Wa.y Shear
48.00,
90.00 psi
Toe Reinforcing
= # 5 @ 6.00 in
Heel Reinforcing
= # 5 @ 14.00 in
Key Reinforcing
= None Spec'd
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm
Heel: #4@ 10.00 in, #5@ 15.50 in, #6@ 22.00 in, #7@ 30.00 in, #8@ 39.50 in, #9@ 5
Key: No key defined
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 11.11 in
#5@ 17.22 in
#6@ 24.44 in
1.40 in2
0.22 in2 A
If two layers of horizontal bars:
#4@ 22.22 in
#5@ 34.44 in
#6@ 48.89 in
Summary of Overturning & Resisting Forces & M�oments �J
..... OVERTURNING ... ..... RESISTING .....
Force Distance Force Distance Moment
Item lbs ft ft-# ibs ft ft_#
Heel Active Pressure
Surcharge over Heel
Surcharge Over Toe
Adjacent Footing Load
Added Lateral Load
Load @ Stem Above Soil
Seismic Earth Load
1,365.5 2.94
437.0 4.42
4,020.6
1,929.9
Tota 1 1,802.4 O.T.M. 5,950.5
Res isti ng/Overturning Ratio 3.99
Vertical Loads used for Soil Pressure 6,169.2 lbs
If seismic is included, the OTM and sliding ratios
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201
Vertical component of active lateral soil pressure IS considered in the
calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS considered in the
calculation of Overturning Resistance.
Soil Over Heel
4,S06.7 4.33
19,528.9
Sloped Soil Over Hee
Surcharge Over Heel
Adjacent Footing Load =
Axial Dead Load on Stern =
• Axial Live Load on Stem =
Soil Over Toe
0.75
Surcharge Over Toe
Stem Weight(s)
850.0 1.83
1,558.3
Earth @ Stem TransitionE
Footing Weigh
812.5 3.25
2,640.6
Key Weight
Vert. Component
6.50
Tota 1
6,169,2 lbs R.M.=
23,727.8
• Axial live load NOT included in total displayed, or used for
overturning
resistance, but is included for soil pressure calculation.
71
RetainPro (c) 1987-2018, Build 1111.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018ACI 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Tilt i
Horizontal Deflection at Ton of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 250.0 pci
Horizontal Defl @ Top of Wall (approximate only) 0.046 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
72
RetainPro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018ACI 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Criteria
[Soil Data
Retained Height
10.00 ft
Allow Soil Bearing 2,700.0 psf
Wall height above soil
0.50 ft
Equivalent Fluid Pressure Method
Active Heel Pressure 35.0 psf/ft
Slope Behind Wall
0.00
H eight of Soi I over Toe
8.00 in
Water hei.clht over heel
0.0 ft
Passive Pressure 0.0 psf/ft
Surcharge Loads
Surcharge Over Heel 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe 0.0
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load 0.0 lbs
Axial Live Load 0.0 lbs
Axial Load Eccentricity 0.0 in
Earth Pressure Seismic [oa-d--J
Method : Uniform
Multiplier Used 8.000
(Multiplier used on soil density)
Design Summary
Wall Stability Ratios
Overturning 3.50 OK
Sliding 1.64 OK
Total Bearing Load 9,015 lbs
... resultant ecc. 7.63 in
Soil Pressure @ Too
1,813 psf OK
Soil Pressure @ Heel
590 psf OK
Allowable
2,700 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe
2,539 psf
ACI Factored @ Heel
827 psf
Footing Shear @ Toe
17.3 psi OK
Footing Shear @ Hee
14.3 psi OK
Allowable
90.0 psi
Sliding Caics
Lateral Sliding Force
2,752.9 lbs
less 0 %Passive Force = -
0.0 lbs
less 100% Friction Force = -
4,507.3 lbs
Added Force Req'd
0.0 lbs OK
.... for 1.5 Stability
0.0 lbs OK
Soil Density, Heel
130.00 pcf
Soil Density, Toe
0.00 pcf
FootingIlSoil Friction
0.500
Soil height to ignore
for passive pressure
0.00 in
Lateral Load Applied to Stem
Lateral Load
0.0 #/ft
... Height to Top
0.00 ft
... Height to Bottom
0.00 ft
Load Type =
Dead Load (D)
(Service Level)
Wind on Exposed Stem =
0.0 psf
(Service Level)
Uniform Seismic Force = 87.333
Total Seismic Force = 953.389
Stem Construction
I
Design Height Above Ftc
ft
Wall Material Above "Ht..
Design Method
Thickness
Rebar Size
Rebar Spacing
Rebar Placed at
Design Data
fb/FB + fa/Fa
Total Force @ Section
Service Level
lbs
Strength Level
lbs
Moment: .... Actual
Service Level
ft-# =
Strength Level
ft-# =
Vertical component of active lateral soil pressure IS
considered in the calculation of soil bearing pressures.
Load Factors -
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
IBC 2018,ACI
1.200
1.600
1.600
1.000
1.000
Moment ..... Allowable
Shear ..... Actual
Service Level
Strength Level
Shear ..... Allowable
Anet (Masonry)
Rebar Depth 'd'
Masonry Data
fm
Fs
Solid Grouting
Modular Ratio 'n'
Wall Weight
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
Concrete Data
fc
Fy
Bottom
Adjaceni Footing Load
Adjacent Footing Load
0.0 lbs
Footing Width
0.00 ft
Eccentricity
0.00 in
Wall to Ftg CL Dist
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall
0.0 ft
Poisson's Ratio
0.300
Stem OK
0.00
Concrete
LRFD
8.00
# 5
6.00
Edge
0.865
3,673.3
13,700.0
15,845.7
psi =
psi = 49.5
psi = 90.0
in2 =
in= 6.19
psi =
psi =
psf 100.0
ASD
psi = 3,600.0
psi = 60,000.0
73
RetainPro(c)1987-2018, Build 11.18.06.30
License: KW-06060370 Cantilevered Retaining Wall Code: �B(' , 2018,ACI 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Concrete Stem Rebar Area Details
Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As (based on applied moment): 0.5188 in2/ft
(4/3) * As : 0.6917 in2/ft Min Stem T&S Reinf Area 2.016 in2
200bd/fy: 200(12)(6.1875)/60000 0.2475 in2/ft Min Stem T&S Reinf Area perft of stem Height: 0.192 in2/ft
0.0018bh : 0.0018(12)(8): 0.1728 in2/ft Horizontal Reinforcing Options :
One layer of: Two layers of:
Required Area 0.5188 in2/ft #4@ 12.50 in #4@ 25.00 in
Provided Area 0.62 in2/ft
#5@ 19.38 in #5@ 38,75 in
Maximum Area: 1.207 in2/ft #6@ 27.50 in #6@ 55.00 in
Footing Dimensions & S-tien-g-t-h-s-A
F -Fooving Design Res�
Toe Width 1.50 ft
Toe Heel
Heel Width 6.00
Factored Pressure 2,539 827 psf
Total Footing Width 7.50
Mu': Upward 2,728 17,528 ft-#
Footing Thickness 11.00 in
Mu': Downward 303 24,533 ft-#
Mu: Design 2,425 7,005 ft-#
Key Width 0.00 in
Actual 1 -Way Shear 17.30 14.30 psi
Key Depth 0.00 in
Allow 1 -Way Shear 48.00 90.00 psi
Key Distance from Toe 0.00 ft
Toe Reinforcing = None Spec'd
fc 3,600 psi Fy 60,000 psi'
Heel Reinforcing = # 5 @ 12.00 in
Footing Concrete Densit� 150.00 pcf
Key Reinforcing = None Spec'd
Min. As % 0.0020
Other Acceptable Sizes & Spacings
Cover @ Top 1.50 @ Btm.= 3.00 in
Toe: Not req'd: Mu < phi*5*lambda*sqrt(fc)*Sm
Heel: #4@ 9.09 in, #5@ 14.09 in, #6@ 20.00 in, #7@ 27.27 in, #8@ 35.91 in, #9@ 45
Key: No key defined
Min footing T&S reinf Area 1.78 in2
Min footing T&S reinf Area per foot 0.24 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 10.10 in #4@ 20.20 in
#5@ 15.66 in #5@ 31.31 in
#6@ 22.22 in #6@ 44.44 in
Summa of Overturning & Resisting Forces & Moments
..... OVERTURNING
..... ..... RESISTING .....
Force Distance
Moment Force Distance Moment
Item lbs ft
ft-# lbs ft ft-#
Heel Active Pressure 2,085.5 3.64
7,589.0 Soil Over Heel 6,933.3 4,83 33,511.1
Surcharge over Heel
Sloped Soil Over Hee
Surcharge Over Toe
Surcharge Over Heel
Adjacent Footing Load
Adjacent Footing Load
Added Lateral Load
Axia I Dead Load on Stem=
Load @ Stem Above Soil
Axial Live Load on Stem
Seismic Earth Load 667.4 5.46
3,642.7 Sol I Over Toe 0.75
Surcharge Over Toe
Tota 1 2,752.9 O.T.M.
Stem Weight(s) 1,050.0 1.83 1,925.0
11,231-8
Earth @ Stem Transition--=
Footing Weigh- 1,031.3 3.75 3,867.2
Res isti nglOverturning Ratio
3.50 Key Weight
Vertical Loads used for Soil Pressure 9,0,14.6 lbs Vert. Component 7.50
Total 9,014.6 lbs R.M.= 39,303.3
If seismic is included, the OTM and sliding ratios
Axial live load NOT included in total displayed, or used for overturning
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS considered in the
calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS considered in the
calculation of Overturning Resistance.
W"
Reta!nPro(c)1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: 113C 2018,ACI 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Tilt i
Horizontal Deflection at Too of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 250.0 pci
Horizontal Def] @ Top of Wall (approximate only) 0.071 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
75
SIMPSON STRONG -TIE COMPANY INC.
5956 W. Las Positas Blvd., Pleasanton, CA 94588
(800) 999-5099
www.strongtie.com
General:
Job Name:
Date: 03/04/2019
Strong Frarne@ Selector 4.7.0.0
Design Criteria:
Design Code: IBC 2015
SDS: 1.00
Seismic Drift Limit: No limit
Wind Drift Limit: No limit
Importance Factor: 1.0
Redundancy Factor: 1.0
ASD Design Loads:
ASD Lateral Loads:
R-load: 6.5
Seismic Load: 10260 lbs
R-Frame: 8.0, Omega:3.0, Cd: 5.5
Wind Load: 6871 lbs
ASID Uniform/Partial Uniform Loads: (Negative for uplift):
Load
Value
(plo
Left End
(ft)
Right End
(ft)
WOU
1004.00
5.50
17.13
WDL2
132.00
0.00
17.13
WDO
0.00
0.00
17.13
Snow Load
0.00
0.00
17.13
Wind Load
0.00
0.00
17.13
ASD Vertical Point Loads: (Negative for uplift):
Engineer:
Frame ID:
FrameModel: SMFX1012-193x117-L
Beam Deflection Limits:
For Live Load: L/360
For Dead + Live Load: L/240
For Snow/Wind Load: L/360
LRFD Lateral Loads:
Seismic Load: 11909 lbs
Note: Frame design is based on factored Seismic Force of
R - load/R - Frame (i.e. when loading is based on R - load = 6.5
and R_Frame of 3.5), then VLRFD =(VASD / 0.7) X (6.5/3.5)
See ASCE 7 section 12.2.3 for combination of lateral system.
Load
Value
(plf)
Left End
(ft)
Right End
(ft)
WLr
1180.00
5.50
17.13
W_L1
155.00
0.00
1 17.1
WLL2
0.00
0.00
17.13
Rain Load
0.00
0.00
17.13
Point Load
Dead Load
Live Load
Roof Live I
Snow
Rain
Wind
I Seismic
I
(lbs)
(lbs)
Load (lbs)
(lbs)
(lbs)
(Ibs)
(lbs) I
P, 6900 1 6110 0 3745 0
I 1 0 0
Point Lc
_�j 5.50
Frame ID: Date: 03/04/2019 Page 2 of 8 76
SIMPSON STRONG -TIE COMPANY INC.
5956 W. Las Positas Blvd., Pleasanton, CA 94588
Stromr-Tie (800) 999-5099
www.strongtie.com
Analyzer SMF Output:
Code Design Summary:
Governing Load Combination (LC)
Simply Supported Beam Deflection DCR
0.98
10: D + Lr
Simply Supported Beam Strength DCR
0.92
40: 1.2 D + 1.6 Lr + 0.5 L
Beam DCR
0.58
40: 1.2 D + 1.6 Lr + 0.5 L
Left Column DCR
01.77
56: (1.2 + 0.2 SDS) D - E + 0.5 L + 0.2S
Right Column DCR
0.77
55: (1.2 + 0.2 SDS) D + E + 0.5 L + 0.2S
Elastic Seismic Deflection (in)
1.10
55: (1.2 + 0.2 SDS) D + E + 0.5 L + US
Seismic Drift (in)
6.03
55: (1.2 + 0.2 SDS) D + E + 0.5 L + 0.2S
Allowable Seismic Drift (in)
N/A
N/A
Seismic Drift Ratio
0.00
N/A
Wind Drift (in)
0.48
22: D + 0.45 W + 0.75 L + 0.75 S
Allowable Wind Drift (in)
No limit
Designer to verify
Wind Drift Ratio
N/A
22: D + 0.4,15 W + 0.75 L + 0.75 S
Link DCR
1.02
55: (1.2 + 0,2 SDS) D + E + 0.5 L + 0.2S
Beam -to -Column Connection DCR
0.71
41: 1.2 D + 1.6 Lr + 0.5 W
Left Base Plate DCR
0.26
56: (1.2 + 0.2 SDS) D - E + 0.5 L + 0.2S
Right Base Plate DCR
0.34
41: 1.2 D + 1.6 Lr + 0.5 W
Beam Deflection (L) (in)
-0,09
2: L
Beam Deflection (D+L) (in)
-0.29
9: D + L
Beam Deflection (D+Lr) (in)
-0.32
10: D + Lr
Beam Deflection (S) (in)
0.04
4: S
Beam Deflection (W) (in)
6: W (Absolute Max)
Maximum LRFD Demand and Member Capacities:
Beam: Demand LC Left Column: Demand LC
PU (kips)
6.00
40
Mu
(kips -in) 1041.59
40
V"
40
P" (kips) 24.22 56
M. (kips-in)� 1041.21 56
V� (kips) �,57 � 56
Beam: Capacity LC Left Column: C apacity
Phi . P, (kips)
153.67
40
Phi. M, (kips -in)
1873,95
40
Phi - Vn (kips)
89.10
40
I
Phi - Pn (kips):
250.94
Phi. M, (kip�s-in)l 1458.00
Phi. V, (kips) 60.75
Riqht Column: Demand LC
P. (kips)
24.66
55
M,, (kips -in)
1040.65
55
V" (kips)
_____T
9.57
155
Riqht Column: Capacity
Phi - Pn (kips)
250.94
Phi. M,(kips-in)
1458.00
Phi - Vn (kips)
60.75
Disclaimer:
It is the designer's responsibility to verify product suitability under applicable building codes. In order to verify code listed applications
please refer to the appropriate product code reports at www.stroiigtie.com or contact Simpson Strong -Tie Co. Inc. at 1-800-999-5099.
Frame ID: Date: 03/04/2019 Page 3 of 8 77
SIMPSON STRONG -TIE COMPANY INC.
5956 W. Las Positas Blvd., Pleasanton, CA 94588
(800) 999-5099
www.strongtie.com
Member Design Summary for Capacity Forces/Oimega Forces (ESR-2802 Step 13):
Components
Demand -to -Capacity Ratio (DCR)
Beam
0.53
Left Column
1.00
Right Column
1.00
Max Column Panel Zone
1.03
Left Column Base Plate
0.32
Right Column Base Plate
0.32
Connection Design Summary for Capacity Forces/Omega Forces:
Components
Demand -to -Capacity Ratio (DCR)
Shear Plate Bolts
0.49
Shear Plate Yield/Rupture
0.71
Shear Plate Axial+Moment
0.63
Shear Plate Bearing
0.41
Shear Plate Block shear
0.39
Shear Plate Welds
0.94
Beam Web Bearing
0.51
Beam Web Block Shear
0.53
Stiffener Tension/Compression
0.63
Stiffener Welds
0.60
- - - ___------------
LRFD Demand And Member Capacity (ESR-2802 Step 12):
Demand From Frame Mechanism:
Beam: Demand Left Column: I)emand
Pu (kips)
11.38
Mu (kips -in)
1140.75
Vu (kips)
29.18
Pu (kips)
29.77
Mu (kips -in),
1374.21
Vu (kips)
1 7.93
Demand From Omega Load Combinations (LCM 61-64):
Beam: Demand LC Left Column: Demand LC
P,, (kips)
20.74
62
Mu (kips -in)
2374.45
62
Vu (kips)
36.82
62
Member Capacities:
Beam: Capacity
Phi. P,, (kips)
153.67
Phi - Mn(kips-in)
2304.00
Phi. Vn (kips)
89.10
P, (kips) 37.20
62
M,, (kips -in)!. 2374.45
62
V� (kips); 21.83
62
Left Column: Capacity
Phi. P, (kips)
250.94
Phi Mn (kips -in)
1458.00
Ph[ Vn (kips)
60.75
Riqht Column: Demand
Pu (kips)
29.77
M,, (kips -in)
1374.21
V,, (kips)
7.93
Right Column: Demand LC
Pu (kips)
37.64
61
Mu (kips -in)
2371.60
61
Vu (kips)
21.81
61
Right Column: Capacity
Phi. P,, (kips) 250.94
Phi. M,, (kips -in) 1458.00
Phi - Vn (kips) 60.75
Frame ID: Date: 03/04/2019 Page 4 of 8 78
SIMPSON
Stron,gTie
SIMPSON STRONG -TIE COMPANY INC.
5956 W. Las Positas Blvd., Pleasanton, CA 94588
(800) 999-5099
www.strongtie.com
SMF Frame Summary:
ZX V ILLU
INSTALLED 4X BEAM
NAILER TOP NAILER
BEAM
7
2X BEAM ZX FIELD INSTALLED
UC) I NAILL14 NAILER AB REQ'D
0
W1
0
W?
M.
0
2X WOOD NAJLFR
Q
AT COL. TYP.
U I
JI-
COLUMN CENTERLINE TO CENTERLINS
Model: SMFX1012-193x117-L
Custom Size
Yes
Beam Size
W12x35, Steel Beam Depth: 12.5" (See Note 4 below)
Column Size
W10x30, Steel Column Depth: 10.5" (See Note 4 below)
Link Size
L
W1 Dimension
16'-0" (See Note 3 below)
W2 Dimension
18'-3" (See Note 3 below)
Column C.C. Spacing
17'-1 1/2"
HI Dimension
10'-0" (See Note I and 2 below)
H2 Dimension
9'-10 1/2" (See Note 2 and 5 below)
H3 Dimension
8'-3 1/2" (See Note 1 and 5 below)
Steel Beam Length
15'-11 1/4" (W1 - 0.75")
Steel Column Length
9'-9" (H I - 3")
Link Flange To Column Bolting
Snug -tight
Top of Col. Bracing Force (ASD)
0.87 (kips)
Min. Beam Top Nailer B,
Notes
1 . H1, H2, and H3 dimensions assume 1-1/2" thick non -shrink grout.
2. H1 and H2 dimensions assume 1-1/2" thick field installed top plate.
3. Anchorage solution may require additional studs on, side of columns, see anchorage design output for final W1 and W2 dimensions.
4. Column and beam sizes shown are as depth of steel only and do not include nailers-
5. (1) 4x beam top nailer for all frames.
(2) 2x beam bottom nailer as required, H3 assumes (2) 2x bottom nailers.
6. Simpson Strong -Tie@ Strong Frame@ and the Yield-LinkTm structural fuseare protected under US patent number 8,001,734,
B2 and must be supplied or licensed through Simpson Strong -Tie.
Frame ID: Date: 03/04/2019 Page 5 of 8 79
SIMPSON STRONG -TIE COMPANY INC.
Strong -Tie
5956 W. Las Positas Blvd., Pleasanton, CA 94588
(800) 999-5099
www.strongtie.com
Foundation Forces (ASD):
Left Column (Node 1) Reactions:
Load
Cases
Shear
(kips)
Axial
(kips)
D
2.08
10.35
L
0.89
5.47
Lr
1.28
4.66
S
0.41
2.54
R
0.00
0.00
W
5.73
-6.06
-4.17
-4.41
Load
Combination
a Shear
(kips)
Axial with Max Shear
(kips)
27
7.16
22.45
Load
Min Shear
ial with Min Shea
Combination
(kips)
(kips)
r 1
-3.25
0.31
Load
Combination
Shear with Max Tension
(kips)
Max Tension
(kips)
34
-3.25
0
Load
Shear with
Combination
Max Compression
Max Compression
(kips)
(kips)
27
7.16
22.45
Right Column (Node 4) Reactions:
Load
Cases
Shear
(kips)
Axial
(kips)
D
-2.08
11.63
L
-0.89
3.29
Lr
-1.28
9.06
S
-0.41
1.20
R
0.00
0.00
W
-5.72
6.06
0.71E
-4.16
4.41
Load
Combination
Max Shear
(kips)
Axial with Max Shear
(kips)
35
3.24
0.90
Load
Combination
Min Shear
(kips)
Axial with Min Shear
(kips)
26
-7.15
25.54
Load
Combination
Shear with Max Tension
(kips)
Max Tension
(kips)
35
3.24
0
Load
Shear with
Combination
Max Compression
Max Compression
(kips)
(kips)
26
7.15
25.54
Foundation Forces (LIRIFID), Load Combination 36-60:
Left Column (Node 1) Reactions: Right Column (Node 4) Reactions:
Load
Combination
ax Shear
(kips)
ial with Max Shear
(kips)
56
9.57
24.22
Load
Combination
1!i
Min Shear
(kips)
Axial with Min Shear
(kips)
5 9
-4.58
n F
Load
Combination
Shear with Max Tension
(kips)
Max Tension
(kips)
59
-4.58
0
Load
Shear with
Combination
Max Compression
Max Compression
(kips)
(kips)
56
9.57
24.22
Load
Combination
Max Shear
(kips)
Axial with Max Shear
(kips)
60
4.57
1.76
Load
Combination
Min hear
(kips)
Axial with Min Shear
(kips)
55
-9.57
24.66
Load
Combination
Shear with Max Tension
(kips)
Max Tension
(kips)
60
4.57
0
Load
Combination
Shear with
Max Compression
(kips)
Max Compression
(kips)
41
-7.51
31.60
Foundation Forces (LRFD), Omega Load Combination and Frame Capacity:
Frame ID: Date: 03/04/2019 Page 6 of 8 80
SIMPSON STRONG -TIE COMPANY INC.
Stron.&Tie
5956 W. Las Positas Blvd., Pleasanton, CA 94588
(800) 999-5099
www.strongtie.com
Left Column (Node 1) Reactions:
Load
Shear(kips)
Axial (kips)
Combination
Omega
Capacity
Abs Min.
Omega
Capacity
I Abs Min.
61
-14.99
-7.93
-7.93
-1 74
-29.77
-1.74
62
21.83
7.93
7.93
37.20
29.77
29.77
63
-16.67
-7.93
-7.93
-11.90
-29.77
-11.90
64
19.55
7.93
7.93
26.39
29.77
26.39
Right Column (Node 4) Reactions:
Load
Shear(kips)
Axial (kips)
Combination
Omega
Capacity
Abs Min.
Omega
Capacity
I Abs Min.
61
-21.81
-7.93
-7.93
37.64
29.77
29.77
62
14.96
7.93
7.93
-1.31
-29.77
-1.31
63
-19.51
-7.93
-7.93
27.28
29.77
27.28
64
16.63
7.93
7.93
1 - 11.00
-29.77
-11.00
Frame ID: Date: 03/04/2019 Page7of8 81
SIMPSON STRONG -TIE COMPANY INC.
5956 W. Las Positas Blvd., Pleasanton, CA 94588
(800) 999-5099
www.strongtie.com
Anchorage Design For:
Job Name:
Engineer:
Date: 03/04/2019
Frame ID:
Strong FrameO Selector 4.7.0.0
FrameModel: SMFX1012-193x117-L
Foundation Type: Slab -on -Grade
Anchorage Design Details: MFSL
Anchorage Model: MFSL-18-6
Anchorage SQ Footing Width, W: 19.00"
Anchorage Grade: F1554 GR.36, Diameter: 0.750"
Anchorage Footing Depth, D: 10.00"
Extension Kit: Not Required
Concrete Code: ACI 318-14 Concrete fc': 3000 psi
Step Height: 5"
Concrete: Cracked SDC: D
Min. Edge Distance: 2.125", Embedment,de: 6.00"
Left Column:
Right Column:
End Distance: 5.250" (Additional studs are not required)
End Distance: 5.250" (Additional studs are not required)
Final Frame W1 and W2 Dimensions (Including Additional End
Distance where required for Anchorages):
Wl: 16'-0" W1 Final: 16-0"
W2: 18'-3" W2 Final: 18'-3"
Plan View: Section View:
END DISTANCE
PRE -ATTACHED DISTANCE
2X NAILER
cll�
<
VA I I 1�
C111
W/2 Z
MFSL
V C)
LLJ C� WIDTH
Notes:
1 . Actual footing/grade beam size and reinforcing must be determined by Designer based on project specific geometry
and allowable soil bearing pressures.
2. The following end distance corresponds to pre -installed wood nailer flush with end of concrete: C64.5", C94.5", C12-
6", C1 5-7.5", C1 8H-1 0.5", C21 H-1 2", W8x48-4.25", W&U-4.5", W1 Ox3O-5.25", W1 Ox45-4.675", W1 2x35-6.25",
W1 2x45-5.675", W1 4x38-7.05", W1 4x53-6.575", W1 6x57-8.20", W1 U40-8.95", W1 8x55-8.675".
1 End distance is measured from centerline of nearest anchor bolt to edge of concrete.
Frame ID: Date: 03/04/2019 Page 8 of 8 82
PAGE NO. 1
Tuesday, April 02, 2019, 11:00 PM
STAAD.Pro VSi SZLZCTseriea5
Version 20.07.10.64
Proprietary Program of
Bentley System, Inc.
Date- APR 2, 2019
Time= 22:59:27
USER ID:
1. STAAD SPACE
INPUT FILE: STEEL COLUMN.STD
2. START JOB INFORMATION
3. ENGINEER DATE 02-APR-19
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT FEET KIP
7. JOINT COORDINATES
8. 1 0 0 0; 2 0 10 0; 3 0 21 0; 4 0 30 0
9. MEMBER INCIDENCES
10. 1 1 2; 2 2 3; 3 3 4
11. DEFINE MATERIAL START
12. ISOTROPIC STEEL
13. E 4.176E+006
14. POISSON 0.3
15. DENSITY 0.489024
16. ALPHA 6E-006
17. DAMP 0.03
18. TYPE STEEL
19. STRENGTH FY 5184 FU 8352 RY 1.5 RT 1.2
20. END DEFINE MATERIAL
21. MEMBER PROPERTY AMERICAN
22. 1 TO 3 TABLE ST HSST6X6X0.25
23. CONSTANTS
24. MATERIAL STEEL ALL
25. SUPPORTS
26. 1 FIXED
27. 2 TO 4 FIXED BUT FY MY
28. DEFINE WIND LOAD
NOTE: If any floor diaphragm is present in the model Wind Load definition
should be defined after Floor Diaphragm definition. Otherwise mind
load generation may be unsuccessful during analysis.
29. TYPE 1 WIND 1
30. <! STAAD PRO GENERATED DATA DO NOT MODIFY
31. ASCE-7-2010:PARAMS 110.000 MPH 0 1 3 0 0.000 FT 0.000 FT 0.000 FT I -
32. 1 30.000 FT 26.000 FT 14.000 FT 2.000 0.010 0 -
33. 0 0 0 0 0.701 1.000 1.000 0.850 0 -
OR
C:\Users\AECPARVINDER\Dropbox\US PROJECTSWR801-MIRE BAKSHI 15712 - 72 AVE. WEST,EDMONDS,WASHINGTON\SWORK\CALCULATI'O)$S\2
f STAAD SPACE
- - PAGE NO. 2
Tuesday, April 02, 2019, 11:00 PM
34. 0 0 0 0.877 0.800 -0.550
35. !> END GENERATED DATA BLOCK
36. INT 0.0207644 0.0207644 0.0212075 0.0214134 0.0216103 0.021799 -
37. 0.0219805 0.0221552 0.0223238 0.0224867 0.0226445 0.0227974 0.0220458 0.02309
38. HEIG 0 15 16.1539 17.3077 18.4615 19.6154 20.7692 21.9231 23.0769 -
39. 24.2308 25.3846 26.5385 27.6923 28.8462 30
40. EXP 0.5 JOINT I TO 4
41. LOAD I LOADTYPE DEAD TITLE LOAD CASE 1
42. SELFWEIGHT Y -1
43. JOINT LOAD
44. 4 FY -2.86
45. 3 FY -4.5
46. 2 FY -5
47. LOAD 2 LOADTYPE LIVE REDUCIBLE TITLE LOAD CASE 2
48. JOINT LOAD
49. 4 FY -3
50. 3 FY -6.5
51. 2 FY -6.2
52. MEMBER LOAD
53. 1 TO 3 UNI GX 0.235
54. LOAD COMB 3 COMBINATION LOAD CASE 3
55. 1 1.25 2 1.5
56. PERFORM ANALYSIS PRINT ALL
PROBLEM STATISTICS
NUMBER OF jonns 4 NUMBER OF MEMBERS 3
NUMBER OF PLATES 0 NUMBER Of SOLIDS 0
NUMBER OF SURFACES 0 NUMBER Or SUPPORTS 4
SOLVER USED IS THE OUT-OF-CORZ BASIC SOLVER
ORIGINAWFINAL BAND-WIDTHm 1/ 1/ 4 DOF
TOTAL PRIMARY L40AD CASES = 2, TOTAL DEGREES Or FREEDOM
TOTAL LORD COMBINATION CASES = 1 SO FAR.
SIZE OF STIFrNESS MATRIX = 1 DOUBLE KILO-WORDs
RZORDAVAIL. DISK SPACE = 12.0/ 227984.9 1MB
e' I
C:\UserskAECPARVINDERIDropboxkUS PROJECTSWR801-MIKE BAKSHI 15712 - 72 AVE. WEST,EDMONDS,WASHINGTON\SWORK\CALCULATYO'AS\2
Tuesday, April 02, 2019, 11:00 PM
' STAAD SPACE -- PAGE NO. 3
LOADING I LOADTYPE DEAD TITLE LOAD CASE I
-----------
SELFWEIGHT Y -1.000
ACTUAL WEIGHT OF THE STRUCTURE 0.534 KIP
JOINT LOAD - UNIT KIP FEET
JOINT FORCE-X FORCE-Y FORCE-Z MOM-x MOM-Y MOM-Z
4 0.00 -2.86 0.00 0.00 0.00 0.00
3 0.00 -4.50 0.00 0.00 0.00 0.00
2 0.00 -5.00 0.00 0.00 0.00 0.00
LOADING 2 LOADTYPE LIVE REDUCIBLE TITLE LOAD CASE 2
-----------
JOINT LOAD - UNIT KIP FEET
JOINT
FORCE-X
FORCE-Y
FORCE-Z
MOM-Y
MOM-Z
4
0.00
-3.00
0.00
0.00
0.00
0.00
3
0.00
-6.50
0.00
0.00
0.00
0.00
2
0.00
-6.20
0.00
0.00
0.00
0.00
MEMBER
LOAD - UNIT KIP FEET
MEMBER
UDL
Ll
L2 CON
L
LIN1
LIN2
1
0.2350
GX 0.00
10.00
2
0.2350
GX 0.00
11.00
3
0.2350
GX 0.00
9.00
FOR LOADING - 1
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-x mom-Y MOM-Z
1 O.00OOOE+00-8.89752E-02 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00
2 O.00OOOE+00-5.18685E+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00
3 O.00OOOE+00-4.67795E+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00
4 O.00OOOE+00-2.94008E+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. I
LOADTYPE DEAD TITLE LOAD CASE 1
nrl
C: \Users \AECPARV1NDER\DropboxkUS PROJECTS\ URB01-MIRE BAKSHI 15712 - 72 AVE. WEST,EDMONDS, WASHINGTON\ SWORICk CALCULATROMS \ 2
Tuesday, April 02, 2019, 11:00 PM
1 0 STAAD SPACE
-- PAGE NO. 4
CENTER OF FORCE BASED ON Y FORCES ONLY (FEET).
(FORCES IN NON -GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)
X - O.00OOOOOOOE+00
Y = 0.184822805E+02
Z = O.00OOOOOOOE+00
... TOTAL APPLIED LOAD KIP FEET ) SUMMARY (LOADING 1
SUMMATION FORCE-X 0.00
SUMMATION FORCE-Y -12.89
SUMMATION FORCE-Z 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN-
MX= O.00OOOOOE+00 MY= O.00OOOOOE+00 MZ= O.00OOOOOE+00
***TOTAL REACTION LOAD( KIP FEET ) SUMMARY (LOADING 1
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 12.89
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN-
MX= O.00OOOOOE+00 MY= 0.0000030E+00 MZ= O.00OOOOOE+00
MAXIMUM DISPLACEMENTS ( INCH /RADIANS) (LOADING 1)
MAXIMUMS AT NODE
X = O.00OOOE+00 0
Y = -1.88187E-02 4
Z = O.00OOOE+00 0
RX= O.00OOOE+00 0
RY= O.00OOOE+00 0
RZ= O.00OOOE+00 0
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KIP FEET )-
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
1 0.00 -0.09 0.00 0.00 0.00 0.00
0.00 -12.80 0.00 0.00 0.00 0.00 111111
FOR LOADING - 2
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-2 MOM-X MOM-Y Mom-Z
1 1.17500E+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00-1.95833E+00
2 2.46750E+00-6.20000E+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00-4.11250E-01
3 2.35000E+00-6.50000E+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00 7.83333E-01
4 1.05750E+00-3.00OOOE+00 O.00OOOE+00 O.00OOOE+00 O.00OOOE+00 1.58625E+00
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 2
LOADTYPE LIVE REDUCIBLE TITLE LOAD CASE 2
C: \Users \AECPARVINDERkDropboxkUS PROJECTSWR801-MINE BAKSHI 15712 - 72 AVE. WEST,EDMONDS, WASHINGTOM SWORK\ CALCULATRONS \ 2
I - bTAMU Z)rA1_z
-- PAGE NO. 5
Tuesday, April OZ� 2019, 11:00 PM
CENTER OF FORCE
BASED ON X FORCES ONLY
(FEET).
(FORCES IN NON -GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)
X -
0.000000000E+00
Y =
0.150000006E+02
Z =
O.00OOOOOOOE+00
CENTER OF FORCE
BASED ON Y FORCES ONLY
(FEET).
(FORCES IN NON -GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)
X =
O.00OOOOOOOE+00
Y =
0.183757968E+02
Z =
O.00OOOOOOOE+00
***TOTAL APPLIED LOAD
KIP FEET ) SUMMARY (LOADING 2
SUMMATION FORCE-X
7.05
SUMMATION FORCE-Y
-15.70
SUMMATION FORCE-Z
0.00
SUMMATION OF MOMENTS
AROUND THE ORIGIN-
MX= 0.00 MY= 0.00 MZ=
-105.75
***TOTAL REACTION LOAD(
KIP FEET ) SUMMARY (LOADING 2
SUMMATION FORCE-X =
-7.05
SUMMATION FORCE-Y =
15.70
SUMMATION FORCE-Z -
0.00
SUMMATION OF MOMENTS
AROUND THE ORIGIN-
MX= 0.00 MY= 0.00 Mz=
105.75
MAXIMUM DISPLACEMENTS (
INCH /RADIANS) (LOADING
2)
MAXIMUMS AT NODE
X = O.00OOOE+00
0
Y = -2.27823E-02
4
Z = O.00OOOE+00
0
RX= O.00OOOE+00
0
RY= O.00OOOE+00
0
RZ= O.00OOOE+00
0
EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KIP
FEET
JT EXT FX/ EXT FY/
EXT FZ/ EXT MX/
EXT MY/ EXT MZ/
INT FX INT FY
INT FZ INT MX
INT MY INT MZ
SUPPORT=1
1 1.17 0.00
0.00 0.00
0.00 -1.96
0.00 -15.70
0.00 0.00
0.00 0.00
111111
2 2.47 -6.20
0.00 0.00
0.00 -0.41
0.00 6.20
0.00 0.00
0.00 0.00
101101
3 2.35 -6.50
0.00 0.00
0.00 0.78
0.00 6.50
0.00 0.00
0.00 0.00
101101
4 1.06 -3.00
0.00 0.00
0.00 1.59
0.00 3.00
0.00 0.00
0.00 0.00
101101
0_7
C:\UserskAECPARVI.VDERkD.ropbox\US PROJECTSWR801-MIKE BAKSHI 15712 - 72 AVE. WEST,EDMONDS,WASHINGTON\SWORK\CALCULAT.YO�S\2
Tuesday, April 02, 2019, 11:00 PM
" '* f' STAAD SPACE PAGE NO. 6
LOAD COMBINATION NO. 3
COMBINATION LOAD CASE 3
LOADING- 1. 2.
FACTOR - 1.25 1.50
END OF DATA FROM INTERNAL STORAGE
57. PARAMETER 1
58. CODE AISC UNIFIED 2010
59. CHECK CODE ALL
4%4%
C:\Users\AECPARVINDERkDropboxkUS PROJECTS\URS01—MIRE BAKSHI 15712 - 72 AVE. WEST,EDMORDS,WASHINGTON\SWOPK\CALCULATYOYS\2
'A %-Amp-- STAAD SPACE
-- PAGE NO. 7
Tuesday, April 02, 2019, 11:
I
STAAD.PRO CODE CMXCZING - (AISC-360-10-LRM) v1.3a
ALL UNITS ARE - KIP INCH (UNLESS OTHERWISE Noted)
MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/
rx MY NZ LOCATION
1 ST HSST6X6XO.25
(AISC
SECTIONS)
PASS
Eq.
H1-1a
0.355
3
39.67 C
0.00
35.25
0.00
2 ST HSST6X6XO.25
(AISC
SECTIONS)
PASS
Eq.
H1-1b
0.201
3
23.69 C
0.00
42.65
0.00
3 ST HSST6X6XO.25
(AISC
SECTIONS)
PASS
Eq.
H1-1b
0.106
3
8.28 C
0.00
28.55
0.00
60. FINISH
END OF THE STAAD.Pro RUN
DATE= APR 2,2019 TIME= 22:59:33
C:kUsers�AECPARVINDERkDropboxkuS PROJECTSWR801—MIKE BAKSMI 15712 - 72 AvE. WEST,EDMONDS,T#ASHINGTON\SWORK\CALCULATIP'O�%S\2
GENERAL CONSTRUCTION NOTES
CODE:
0 ESIGN AN 0 CONSTRUCTION SHALL CONFORM TO THE PROVISIONS OF
THE 20 1 5 IBC AS ADOPTED BY rHt CITY OF EDMONDS, WASHINGTON
D ISCREPANCIES:
I'
THE CONTRACTOR SHALL NOTIFY ENGINEER UPON FINDING ANY
DISCREPANCY OR OMISSION IN THE DRAWINGS OR SPECIFICATIONS.
SHORING & EXCAVATION:
THE CONTRACTOR SHALL BE SOLEY RESPONSIBLE FOR ALL EXCAVATION
PROCEDURES AND PROTECTION OF AD�ACIINT PROPERTY.
BACKFILL SOIL
SEE GEOTECHNICAL ENGINEER FOR ALL BACKPILL MATERIAL AND
COMPACTION REQUIREMENTS
DESIGN CRITERIA
FOUNDATION DESIGN:
REY A INING WALL DESIGN IS BASED ON THE FOLLOWING VALUES AS
PROV 10 E 0 IN THE GE07ECHNICAL REPORT BY GEOTECH CONSULTANTS
INC. DATED 01-25 _113 & E-MAIL CORRESPONDENCE OF 09-27-19�
ALLOWABLE 5EARING PRE55URE 3,000 PSF
LATERAL EARTH PRESSURES DRAINED BACKFILL
ACTIVE CONDITION 35PCF EFW I LEVEL BACKFILL I
PASSIVE CONDITION: 30OPCF EFW ULTIMATE
SEISMIC ADDITION 1 = 8H PSF UNIFORM
SATURATED SOIL DENSITY 125 POP ./ LEVEL BACKPILL
COEFF OF FRICTION. 050 ULTIMATE
SPECIAL INSPECTION PLAN
QUALIFICATION:
TH E SPE CIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL
OE MON 5 TRAIT COMPETENCE, TO THE SATISFACTION OF THE BUILDING
OFFICIAL,
REQUIRED VERIFICATION & INSPECTION:
THE SPEC I AL INSPECTOR SHALL PERFORM THE VERIFICATIONS
INSPECTIONS NOTED IN THE SCHEDULE BELOW
INSPECTION & TESTING SCHEDULE
--TYPfS OF WORK — -------
2 5
�tQSOEICT1105G
CAST IN PLACE GONG
REINFORCING STEEL, PLACEMENT.
P
1705.3
PLACEMENT OF CONCRETE
C
1705.3
VERIFYING USE OF REQUIRED DESIGN M IX-
P
1705.3
TE STING OF THE CONCRETE FOR SPEC 'FIED
STRENGTH. AIR CONTENT AMC) SLU MP
C
1705.3
VERIFICATION OF 5OIL-BEARING CAPACITY
INSTALLATICN OF DRAINAGE SYSTEM!
1705.6
PLACEMENT & COMPACTION OF WALL
-5ACKPILL
P
170.6
FREQUENCY LEGEND
C CONTINUOUS P = PERIODIC
CONCRETE
CONCRETE REQUIREMENTST
LOCATION STRENGTH MAX W/C RATIO
WALLS & FTGS 300OPSI @ 28 DAYS 0,50
AIR CONTENT.
CONC EXPOSED TO WEATHER SHALL CONTAIN 5% I-iX ENTRAINED AIR.
MIX OESIGN�
SHALL BE BASED ON FIELD EXPERIENCE OR TRIAL MIXTURES IN
CONFORMANCE WITH THE SPECIFICATIONS.
MATERIAL REQUIREMENTS:
GEM ENT. ASTM C150, ADMIXTURES ACI 301
AGGREGATES A5TM C33 WATER ASTM C94
EXPOSURE CATEGORIES:
FREEZING THAWING FO
SU�FATE so
IN CONTACT ./ WATER wo
CORROSION PROTECTION CI
PLACING REQUIREMENTS:
PLACE CONCRETE AS NEARLY AS PRACTICABLE TO ITS FINAL POSITION
TO AVOID SEGREGATION.
REMOVE ALL DEBRIS FROM FORMS PRIOR TO PLACING CONCRETE
CON50LIDATE CONCRETE BY SUITABLE MEANS. THOROUGHLY WORK
CONCRETE AROUND EMBEDDED ITEMS AND INTO CORNERS OF FORMS
REINFORCING BAR
MATERIAL REQUIREMENT,.
REINFORCING BARS:
USE DEFORME D BARS CONFORMING TO ASTM A615, GRADE 60.
FABR�CATION AND PLACING REQUIREMENTS:
BEND NG:
BARS SHALL BE BENT COLD BARS PARTIALLY EMBEDDED IN CONCRETE
SHALL NOT BE FIELD BENT UNLESS NOTED OR SHOWN OTHERW15E OR
AUTHORIZED BY THE ENGINEER
CONCRETE COVER:
MINIMUM CONCRETE COVER FOR REINP SHALL BE AS FOLLOWS, UNLESS
NOTED OTHERWISE:
CONCRETE CAST AGAINST EARTH-3"
CONCRETE CAST AGAINST FORMS AND
EXPOSED TO EARTH
WET SETTINGS:
REINFORCEMENT ANCHOR BOLTS, OR ANY EMBEDDED ITEM WITHIN THE
CONCRETE MAY NOT BE SET INTO THE CONCRETE AFTER IT HAS BEEN
POURED W�THIN THE FCRMS
LAP SPLICES:
LAP ALL BARS 24" MIN UNLESS SHOWN OTHERWISE ON THESE OWGS.
- - - - - - - - - -
2
- -- - - - - -
PROPERTY
LINE
- - - - - - - -
00'
--------- Opp;-
t
----------
----- ------- --
2595
---------
2560
0
---
-----
i-
I-
52 1 / - -
: k,2 i
2623 _2/
F6-6�1 27
2 GARAGE FFE=257.0
BASEIVIEW4E=258.0
40 --MAIN FFE=267.0
2610
, // - / (��r / BUILDING FOUNDATION
- - - - - - - ALL ELEMENTS OF THE BUILDING FOUNDATION SHALL BE AS
SHOW IN THE STRUCTURAL DRAWINGS BY MAINLAND
ENGINEERING CONSULTANTS CORP (MECCI EXCEPT FOR THOSE
-1 0� - - - - -
10
PORTIONS ON THE NORTH AND EAST WALL ADJACENT TO
THE TEMPORARY ECOLOGY BLOCK RETAINING WALL AND AS
-
CP
"d,
4-
DETAILE ON THIS SHEET SEE MECC FOUNDATION DRAWINGS
FOR ALL WALL LENGTH$ AND ANCHORAGE OF WOOD FLOOR
FRAMING TO THE TOP OF THE WALL.
oo
9E--------------
52
-�E ------------
------
---
-------------
�E ----------
-------
----260 -------------
----nn7
TEMPORARY SITE SHORING PLAN
FOR HOME FOUNDATION
CONSTRUCTION & ALTERNATE E)SMT WALL DESIGN 2,
SCALE 1/8" = 1'-0"
7— 4'
161
ALL WORK SUBJECT APPROVED
TO FIELD
INSPECTION FOR PLANS MUST BE SI Reports for Soils,temp retaining wall and
I
CODE COMPLIANCE rstructural required prior to final.
ON JOB SITE Please see attachments for the Two SI
agreements.
Citv Of Edmonds
Building Department
Work Revision to basement wall and foundation
Address 15712 72nd Avenue West
Owner Sharma, Amit
Approved Date 511312020
Building Official -D�xrcnmm W. W
Permit Number BLD2018-1 101
CITY OF EDMONDS
BUILDING DIVISION
-APPROVED PLAN
PLAN KEYNOTES
I BASEMENT WALL AND FOUNDATION AS DESIGNED BY
MEEC EXTEND ALL LONGITUDINAL WALL AND FTG REINF
INTO ALTERNATE WALL AND fTG SECTION PROVIDE
CORNER BARS AS DIRECTED BY MECC.
2. THIG4ENO SLAB EDGE FTG AS SHOWN IN THE MECC
STRUCTURAL DRAWINGS
3, BOTTOM OF: ECXACATION LINE AT ELEVATION 256
ASSUMING NO TEMPORARY SITE SHORING ECOLOGY BLOCK
RETAINING WALL
4 OUTLINE OF HOUSE FOUNDATION WALLS AT THE
5A5EMENT LEVEL. SEE NECC STRUCTURAL DRAWINGS FOR
ALL DIMENSIONS AND FOUNDATION INFORMATION.
LEGEND
w
TEMPORARY ECOLOGY BLOCK SHORIN WALL
SEE COBALT GEOSCIENCES FOR ALL INFORMATION
------ > 15HIO DOWNWARD SLOPE
0
BUILDING FOUNDATION AS ORIGINALLY DE51GNED �i
BY MAINLAND ENGINEERING CON SULTANT5 CORP 'S
TO REMAIN.
<
RE V [SEC BUILDING FOUNDATION AS DETAILED AND
SHOWN IN THIS DRAWING SET
UPPER SITE RETAINING 'NALL AND SITE STAIRS TO r&W EA. J. Ira
BE CONSTRUCTED AT ALATEROATEUNDERA
5EPERATE PERMIT.
ORIGINAL SITE GRADES PRIOR TO PREVIOUS 411, AL
SITE EXCAVATION WORK
AL
Ei�'\ILEVATICN AT TOP G1 CUT ALONG BACK OF
TEMPORARY ECOLOGY BLOCK WALL
HEIGHT OF BACKFILL ALONG BACK OF TEMPORARY
ECOLOGY BLOCK WALL FROM A BOTTOM OF FTG
ELEVATION OF 25600 CO) z
Z 0
0 6
LL1 (.) z
z 2
LLI 9
REQUIRED OBSERVATION LU ad 2 R
C05ALT GEOSCIENCES SHALL VERIFY BLOCK o a
INSTALLATION DURING CONSTRUCTION OF THE Z z
TEMPORARY SITE SHORING WALL LU 2
000
us= LL.
CO) z
LU a
Cr. lu —
I.- CO)
LL1
CO) 0
_j
Cr. >- i z
.0 W.0 On
oc BI: 0
x CC LLI
O�- LL.
Z 0
Uj
LLI a
LU
U)
41C
ca
r6(/,,da4i(4,j �)a/(
RNO
REVISION
Apr 29 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT 1--SHEE:
WALL SECTION
SCALE 1/2"4-01t
2' 0" LAP WALL REINF ON
BACKFILLED OR
OUTSIDE FACE OF
WALL
ALL REINF AT
CENTER OF WALL
WALL TRANSITION DETAILS
SCALE l/2`=I'-0`
(ti/4')
25600
2'-W
WALL SECTI ON
SCALE 1/2'=V-10"
DOWEL & VERT REINF TO BE
LILACEO IN LINE DOWN THE
ENGTH OF THE WALL
FTG TO J L VERT WALL
WALL REINF
DOWEL
(�T�) TYP FTG DOWEL PLACEMENT DETAIL
\,22 / SCALE Vml--O�
WALL ELEVATION
\��SCALIE �I/Vl'-O"
WALL REINF @
CENTER OF WALL
DOWEL & VERT REINP TO BE
PLACED IN LINE DOWN THE
LE NGTH OF THE WALL
J :�,- n
DOWEL FTG TO -1 L VERT WALL
VERT BAR WALL DOWEL REINF
SPLICE
�#4016"o/c HORZ EA
FACE
1� 11RT 1A IAIE
ZWALL REINFORCING
ON OUTSIDE FACE
#5 x24'x24- CORNER BARS
TO MATCH HORZ WALL
#5 .24".24 CORNER BARS
REINF TYP 9
TO MATCH HORZ WALL
I
REINF TYP
#4 VERT SUPPORT -3t
BAR DOWELS TO
WALL REINFORCING
WALL REINFORCING FOOTINGS ARE NOT�
ON OUTSIDE FACE REQUIRED AT
:4 VERT EA FACE
ON OUTSIDE FACE
THESE VERT BAR: 5
4016%ft HORZ EA
TYP WALL COR-NER REINF,
NTS
WALL SECTION
GENERAL KEYNOTES
I APPLY PREFABRICATED DRAINAGE PANEL OR FREE DRAINING BACKFILL BELOW GRADE TO ALL
BACKFILLED WALLS EXTEND DRAINAGE PANEL TO WITHIN 12" OF FINISHED GRADE SEE
GEOTECHNICAL ENGINEER FOR MATERIAL SPECIFICATIONS
2 411* PERFORATED PVC FOOTING DRAIN AT ALL WALL SECTIONS. WRAP IN MINIMUM DRAIN
ROCK BEDDING & FILTER FABRIC ROUTE DRAIN TO DISCHARGE POINT AS SHOWN ON CIVIL DWGS
3 LEAVE SURFACE BETWEEN WALL & FOOTING ROUGH.
4. FINISHED GRADE AT THE BACKFILL FACE OF THE WALL HEIGHT OF BACKFILL SHALL NOT EXCEED
ELEVATION 265.25.
5 CONCRETE SLAB ON GRADE AND SUBGRADE PER THE ORIGINAL MECC STRUCTURAL DRAWINGS CAST
TIGHT TO INSIDE FACE OF THE FOUNDATION WAL�,
6. TEMPORARY ECOLOGY BLOCK SITE RETAINING WALL SEE DOCUMENTS FROM COBALT GEOSCIENCES
FOR ALL ASPECTS OF THE WALL CONSTRUCTION.
7 TEMPORARY SITE GRADING TO ALLOW CONSTRUCTION OF THE BASEMENT WALLS.
8 BACKFILL ELEVATION AT THE STAIR SECTION ALONG THE NORTH WRIL
9. SEE MECC BUILDING STRUCTURAL DRAWINGS FOR ALL DETAILS AND INFORMATION RELATED TO THE
ATTACHMENT OF: THE BUILDING STRUCTURE TO THE TOP OF HE CONCRETE BASEMENT WALL
10 OPENING FOR 4.OFT WIDE BY 5.5FT TALL WINDOW WITHIN THE BASEMENT WALL. CONTRACT TO
LOCATE OPENING WITHIN THE WALL AS SHOWN ON THE ARCH DWGS, IN NO CASE SHALL THE
HEADER OVER THE WINDOW OPENING BE LESS THAN 14" DEEP
WALL SECTION
REINFORCING KEYNOTES
100. 8" THICK CONCRETE WALL. REINF w/ #5@16"olc HORZ & VERT PLACE VERT REINF NEAR THE
BACKFILL FACE OF THE WALL. PROVIDE 2145 CONTINUOUS HORZ BARS @ THE TOP OF THE WALL.
SEE 6152 FOR WALL CORNER REINF.
101 &' THICK CONCRETE WALL REINF ./ #501611cic HORZ & VERT PLACE VERT REINF AT THE CENTER
OF THE WALL. PROVIDE 12)-*5 CONTINUOUS HORZ BARS @ THE TOP OF THE WALL. SEE 6/52 FOR
WALL CORNER RCINF
102. 15 WALL TO FOOTING DOWELS @ 1611 o/c. PROVIDE STD HOOK @ END OF BAR CAST INTO FOOTING.
DOWELS SHALL BE EMBEOD E 0 A MINIMUM OF 911 -/- 1/2" INTO THE 1211 FOOTING AND SHALL
EXTEND INTO THE WALL 28" MIN SEE 5/52 F OR PLACEMENT REQUIREMENTS.
103 15 WALL TO FOOTING DOWELS @ 811 o/c. PROVIDE $TO HOOK @ ENO OF BAR CAST INTO FOOTING.
DOWELS SHALL BE EMBEDDED A MINIMUM OF 9" /- 1/21' INTO THE 1211 FOOTING AND SHALL
EXTEND INTO THE WALL 4411 MIN SEE 51S2 FOR PLACEMENT REQUIREMENTS
104. #5 LONGITUDINAL TOP & 507 AS SHOWN LAP 24" MIN @ ALL SPLICE LOCATIONS.
105. #01611.1c TRANSVERSE.
io6. #5@16110, TRANSVERSE
07 #4 HORZ EA FACE AS SHOWN PROVIDE STD HOOK EA END WHERE SHOWN.
08 #4 VERT EA FACE AS SHOWN
109 #4 DIAGONAL EA FACE EA CORNER OF THE OPENING AS SHOWN
110 (4143 U STIRRUPS OVER OPENING EQUALLY SPACED AS SHOWN
Ill (5144 FOOTING TO WALL DOWELS EA FACE PLACED AS SHOWN.
REVISION
Apr 29 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Lu
0
z
LLI
LLI
m
co)
c
0
1-:
U)
z
31 o
LU
z
Lu
a" a
00
z
00
X LL
co) z
uj CD
Lu
o
-i
_j
01-
CL Z
a Lu
UJ Z
Lu
co)
oc
ca
Lu
IN 1-u
z
0
77'
�-Ji
z
0
LL
0
S20F 2
S-19-0838
SPECIAL INSPECTION AND TESTING AGREEMENT
Permit M BLD2019-0.1929 and -0530
Project: Alain Street Commns - SOILS
Prior te; issuance of a permit, thisform must he completed ity id end"., and returned to the Citt-fir
approvaL 77ieeanipletcdfarmotti.vthatevignature-vof'acknowled,,wnientbj,ullpartie,8.
DUTIES AND RESPONSIBILITIES
Special Inspection Firin and Special Insptaurs:
Thc Special Inspection 111ml ()I'—.
i III perlimn --pe6id Inspection for the tvN,� or%A (irk iwparatc form, m st h itt
& I '- . u, b%- su m ed if mory than
onf." finn is tx) be ernployed):
-Rviv:forced Concrete
Boltino in Concr-ote
M
Pr�;str%Nscul Concicte
Structural )v1.Lsoi*
Strwhinal Sicel."Welding
Ffi,-Yb Swcn-lh Rohir)"
'.ipra,v applied Firliroofing
--Smoke Control SystcrnN
L.ziwmd NN wd
Strit,.-tural Obscrvation by dcsigv professional
X_Grading. Soils Drainage
—Steel, floor and Roof Decks
All 'ndiv idual inspecturs to bev,niplo,.ed on this project will be WABO ccrtifwd for the type ol wor�- tbcyar�e to
inspect, Ifinspection is for �Nurk that i�, not coverecl by the XV\130 catcgorics. or t.he inspector 1:; not \�ABO
certificd, a &-tailod re-,,urtw- of the inspeaor andfimi must bc subinittA The resume must shmA that t1w 111-�P"tor
andl thc fin-n are qualified bN education and Qxlvricne-%: to perforni the work- and testing rcquir,.:d hy thc prt�le�:t
de-;ign and Nivcifications.
Thv work shill bc itispected for eontormance with the plan-, and specificatiom appro% ed by the City. ReN ision,"
1111d Aicndt shxt-, will not t)%.- u--,cd for jnsNction. thoy haw Ivenapproved by the City, hispvctloll
FCC4)rd,, shall includc:
A daily rccord to he rnjilltailw�d 4insitc, iWini/ing the inspection,; perfornwd.. Any nonconforming w(ork
No, firought to the imm,!Ji.ate attention of the contractor for rk!;,
shal 1 Z� . olution,
A \%ocklv r.:port Aall be -;uhmitted to ffic City, detailing the inspections and testing performed. any
noncolltiirnii n v
, work aud rc-,vilution ofnonconforming item,;.
-k f -,or( , 'i — -tarvnietit prior u) tile CertificaW of0ccupane-, K!ing
inal i%r, -hal I L - submitted to the building di�l
issiwd. Thi,� r%�pon A ill indicatz that inspection and testing k%as completed in cont�)rrnjncc with the
approved.plill." spe':irjcation�- and approwd r,:\ isions or addenda. Any unre--,ol%cd discrevancies must be
detailcd in the fin.tirvpon.
Contractor:
Th,; �%Pntracwrshxll provide the special inspwor -or agency adequate notification of vvork requiring ins.pcction.
The City approved p!pn anti spccificitlon, inuq bc md,; availahlu, at the jc1briie for the ust of the pccial
insIvctor and the City inspector. The contractorshall maintain all dail% insNction mports, on site, for re% ieA by
ill parties,
I he special inspvction functions are cotzidured to bc in addition to the normal in-,lvaims performed bN the CiN
and the contractor is responsible for conwing the City toschedulc regular inNpoctunis. No concrate sL11 be
pour,A or other work co%,vred until apprinal is i
giN en hy the City ins.-Iltx1or.
Building Dcoartmene
Thc htjilding (k1rartatclit,41311 rCv1v%% any rcv1sions and jddend:t. The City iwpcctor wiLl monitor thespecial
insp"tion llunetionN for cxnnpliaucc with the aagr,.�,ment and the apprn�,cd plans� The City jusp%wtor shall bQ
rcspoti,,�ible for apprui ing N ariousstagts of constniction to he co% ered and for% ork to proceed,
Design Professionals:
1 fie architect. an& or 4mgincer will clearl) indicateun tha plam, and spvcifitioations the pecific t)peN of special
inspection required and,.4iAll iiwludc a -,vhCJ1LLe for insp�cction and tes-ting. The architectand,'or enginc,�r will
c,x1rdinit-c th,* ro.% ision jn,.! addenda process in such a way a.,. to erstire that all requircd City jpprtj� als are
obtainvd. prior to A orkshoun on the rekisions being performcd in thL field-
011 ner;
*Ib,� project o�&n(v, or th,�architcct orengineer acting ai th%:. Okkliel_; agpont. shall cmplo� the special inspector or
ENtORCENIENT
A fai)urz of the sNcial inspector or firm to perform in keeping %kith th,� r%:4uiremenvs (if the IBC, the approxed
plans and this document. maN % oid this agrecmc.nt and the. Building Official's Wmval of the "pecial ins-pector.
4 —
In Nuch a casca ncu special inNr.hvtorard.'%)r firm would nevil to be propost.-d')rappnival. Afailureol'the
design and or pwiv4:s t . u 1),,rrurni in accordanct; with this agrtvinent may rcmilt in a STOP 'WORK
notice heing postcd on 1�,: projed unfil nonconi- iing iter
orn _, n, hate Kcn rc�,olxed.
ACKNOWLEDGME-NI'S
I ha% e rcad and ag ve
,r, to %:ornpl� %A ith Ithe tvi'm" and coildition., of this agreement.
14:
Date 0
Contractor !�e 6e. —Sigiintur Date: -20
uate: Ed f&W
Arch. big.DA04 FW,,xm" Signature.
?e,iiiCLiCv0,"_ eWG,WC=Lj
Special lnsp.,_�g�rLeyjrammell Sigmature Date; 8/26/2020
Spovial InNp. Agency Otto Rosenau & Associates, Inc.
ACCEPTED FOR ifit- CITY OF FDNI()\DS BUILDINU DIVISY)N
By: Date:
� 1A)%N\ RAN P11 S i" rv,inv SHARl' Rt jt,1)1V.v 01\ !-�10\ HI 1-1; St-r—, k1 hwm%14m� 1;nezia. irmpcaion S! Main stk.,,, '1!10r�
SOU \�AuLv;
LJUUU0IY I I M IV WUPU 1LJ- LJUUF_UU I I -D%,JM- I UE--r- I IA%,ZD I IZ I
of E
A
SPECIAL INSPECTION AND TESTING AGREENIENT
Permit #: BLD2018-1101
Project: Sharma, 15712 72" Avenue W.
-Ke-vision of Basement WaMoundation
Plior to issuance of apermk thisform must be compIded in its endrety and returned to the Cilyfor
approvaL The compktedform must have signatures of acknowkdgment by allpardes.
DUTIES AND RESPONSIBILITIES
The Special Inspection firm of will perform special
rms
inspection -for the following types of work (separate fo must be submitted if more than one fim is to be
employed):
X Reinforced steel/placement
X Placement of Concrete
Verifying use of required
Design mix. Testing of concrete
For specified strength, air content and
slump.
Shotcrete
Structural Masonry
—Structural Epoxy
— High Strength Bolting
Spray applied Fireproofing
Smoke Control Systems
— Lateral Wood
— Structural Observation by design profession
— soils
—Expansion Bolts/Thmded Expansion Inserts
All individual inspectors to be ernployed on this project Will be WABO certffied for the type of work they are to
inspect. If inspection is for work that is not covered by the WABO categories, or the inspector is not wABO
certified, a detailed resume of the inspector and firm must be submitted. The resume must show that the
inspector and the firm are qualified by education and experience to Perform the, work and testing required by the
project design and specifications.
The work shall be inspected for cofformance with the plans and specifications approved by the City. Revisions
and addenda sheets will not be used for inspection, unless they have been approved by the City. Inspection
records shall include:
A daily record to be maintained on site, itemizing the inspections perfbrmed. Any nonconforming work
shall be brought to the immediate attention of the contractor for resolution.
A weekly report shall be submitted to the City; detailing the inspections and testing performed, listing
any nonconforming work and resolution of nonconforming items.
�Wmsw-userfsNusmpr,Df$\dakau\Deskwp\Comments Lettm and Special Inspection forms 2019\Special Inspection fbrms\sl Repon Shama
wdsion basment wall and foundation doc5/12/2020
LJUL;U01yi I L; I I vtjlup� I L). L�L)Ur_ui I I -0%,um- I ur-F- I M%,/-D IF- I
A final report shall be submitted to the building department prior to the Certificate of Occupancy being
issued. This report will indicate that inspection and testing was completed in conformance with the
approved plans, specifications and approved revisions or addenda. Any unresolved discrepancies must
be detailed in the final report.
Contractor:
The contractor shall provide the special inspector or agency adequate notification of work requiring inspection.
The City approved plan and spwifications must be made available, at the jobsite for the use of the special
inspector and the City inspector. The contractor shall maintain all daily inspection reports, on site, for review by
all parties.
The special inspection functions are considered to be in addition to the normal inspections performed by the City
and the contractor is responsible for contacting the City to schedule regular inspections. No concrete shall be
poured or other work covered until approval is given by the City inspector.
uildin De arf�""+-
The building department shall review any revisions and addenda. The City inspector will monitor the special
inspection functions for compliance with the agreement and the approved plans. The City inspector shall be
responsible for approving various stages of construction to be covered and for work to proceed.
Design Profession&ls:
The architect and/or engineer will clearly indicate on the plans and specifications the specific types of special
inspection required and shall include a schedule for inspection and testing. The archit6-ct and/or engineer will
coordinate their revision and addenda process in such a way as to ensure that all required City approvals are
obtained, prior to work shown on the revisions being performed in the field.
Owner:
The project owner, or the architect or engineer acting as the owners agent, shall employ the special ins ector or
agency. p
ENFORCEMIENT
A failure of the special inspector or firm to perform in keeping with the requirements of the IBC, the approved
plans and this document ' may void this agreement and the Building Official's approval of the special inspector.
In such a case a new special inspector and/or firm would need to be proposed for approval. A failure of the
design and/or construction parties to perform in accordance with this agreement may result in a STOP WORK
notice being posted on the project until nonconforming items have been resolved.
ACKNOWLEDGMIENIS
I have read and agree to comply with the terms and conditions oflbj&#
4WpApent.
Owner: AMit Sharma Signature A,4 4AA Date may 15, 2020
Contractor- ZJ / 1 Signature Date.-
L/
Signed by:
Dan Kosnik e L may 15, 2020
Arch./Eng; Sign C wswt Date:
-91AF11111DF111F4E4,
Special Ins
P. Signature— Date:
�\edmsw-userf§\userprofSNdakauNDesktop�COmments Utters and Special Inspection forms 2019\Special Inspection forms\Sl Report Sbama
revision basment wall and foundation doc5/12/2020
LJUL,UOIYI I r- I IV t-,Iuyt� I L-). LJLJUCUL)( r--r-+or---+LPr-i-DUJtA- I Ur-r- I t-%%,ID I r- I
y
Special Insp. Agene
ACCEPTED FOR THE CITY OF EDMONDS BUILDING DIVISION
.4 'anwo ff 'd � I
Date:
\\eftsvr-userfs\usMrof$\dakau\Desldop\Comments Letters and Special Inspection forms 2019\Special inspection forms\S1 Report Sharma
revision basment wall and foundation docS/12/2020
Uuuuolyl I r- I I vtjluyt:: I U. L�L�ur_uo I r--F+-Dr--4UF- I I t'%�,tD I E I
OF E0.40
SPECIAL INSPECTION AND TESTING AGREEMENT
Permit #: BLD2018-1101
Project: Sharma, 15712 72" Avenue W.
Temporary shoring for !Lasement
Wall revision
Prior to issuance of a permit, thisform must be completed its its entirety and returned to tile Cityfor
approval. The completedform must have signatures of acknowledgment by allparties.
DUTIES AND RESPONSIBILITIES
Special Inspection Firm and Sveclal Inspectors -
The Special Inspection firm of
�-LC _Will perform special
inspection for the following types of work (separate forms must be submitted if more than one firm is to be
employed):
— Reinforced steel/placement
— Placement of Concrete
Verifying use of required
Design mix. Testing of concrete
For specified strength, air content and
slump.
Shoterete
Structural Masonry
—Structural Epoxy
— High Strength Bolting
— Spray applied Fireproofing
— Smoke Control Systems
Lateral Wood
Structural Observation by design professioni
X Soils/Installation/construction of temporary
Site shoring plan for home foundation
—Expansion Bolts/Threaded Expansion Inserts
All individual inspectors to be employed on this project will be WABO certified for the type of work they are to
inspect. If inspection is for work that is not covered by the WABO categories, or the inspector is not WABO
certified, a detailed resume of the inspector and firm must be submitted. The resume must show that the
inspector and the firm am qualified by education and experience to perform the work and testing required by the
project design and specifications.
The work shall be inspected for conformance with the plans and specifications approved by the City, Revisions
and addenda sheets will not be used for inspection, unless they have been approved by the City. inspection
records shall include:
A daily record to be maintained on site, itemizing the inspections performed. Any nonconforming work
shall be brought to the immediate attention of the contractor for resolution.
�\edmvr-usafii�userpmfSXdakau\DesktopIComments Loam and Special hispection forms 2010\Special Inspcetion fbm1s\sl Report Sharma
temporary shoring for Basement wall only- Copy-docS/I 2/2020
LIUL,UOIYI I C: I IV t::IL)iJt! I I.J. L�LJUCUL)( r-F+0IZ_+LJC I -DkUM- I Ur-r- 1MU40 I r- I
A weekly report shall be submitted to the City; detailing the inspections and testing performed, listing
any nonconforming work and resolution of nonconforml g items,
A final report shall be submitted to the building department prior to the Certificate of Occupancy being
issued. This report will indicate that inspection and testing was completed in conformance with the
approved plans, specifications and approved revisions or addenda. Any unres-olved discrepancies must
be detailed in the final report.
Contractor:
The contractor shall provide the special inspector or agency adequate notification of work requiring inspection,
The City approved plan and specifications must be made available, at the jobsite for the use of the special
inspector and the City inspector. The contractor shall maintain all daily inspection reports, on site, for review by
all parties.
The special inspection functions arc considered to be in addition to the normal inspections performed by the City
and the contractor is responsible for contacting the City to schedule regular inspections. No concrete shall be
poured or other work covered until approval is given by the City inspector.
Building Department;
The building department shall review any revisions and addenda. The City inspector will monitor the special
inspection functions for compliance with the agreement and the approved plans. The City inspector shall be
responsible for approving various stages of construction to be covered and for work to proceed.
Design P - ssionals:
The architect and/or engineer will clearly indicate on the plans and specifications the specific types of special
inspection required and shall include a schedule for inspection and testing. The architect and/or engineer will
coordinate their revision and addenda process in such a way as to ensure that all required City approvals are
obtained, prior to work shown on the revisions being performed in the field.
Owner:
The project owner, or the architect or engineer acting as the owners agent, shall employ the special inspector or
agency,
ENFORCEMENT
A failure of the special inspector or firm to perform in keeping with the requirements of the IBC, the approved
plans and this document� may void this agreement and the Building Official's approval of the special inspector.
In such a case a now special inspector and/or firm would need to be proposed for approval. A failure of the
design and/or construction parties to perform in accordance with this agreement may result in a STOP WORK
notice being posted on the project until nonconforming items have been resolved,
ACKNOWLEDGMENTS
I have read and agree to comply with the terms and conditions pftW&m
Owner: AMit Sharma —Signature
Contractor: dl� z�lln, 61j,,174' Signature
I/
0-
Arch./Eng: (6�4 0 J�m Lovi-L.,.. . Signature
may 15, 2020
Date
Date: 4/40—
Date:
�kcdinsvr-userfs\userpmfS\dakauTesktop\Conuments Latm and sp"jal Inspection fonns 2019\Speciol Inspection fonns\Sl Report Shanna
tompnmry shoring for Basement wall only- Copy.docS/12/2020
Liuwalyl I r-1 I vulupt: ILJ. LnJur-uz) I r-r40r---+L0Ct-D�,JtA- I %�E--[Z I M%,ZD I F- I
PA
Special Insp. Cignature
L.,--Date:
SPecial Insp. Agenc 6,bn l: Zcx-s
ACCEPTED FOR THE CITY OF EDMONDS BUILDING DIVISION
By: vuwo�� W. W VfALCLIL Date:
\\cdmsw-u3crfa\u3crprvSWakau\DcsktopNComments Letters and Special Inspection fbnus 2019\Special Inspection formsNST Report Sharma
temporary shoring for Basement wall only- Copy.docS/12/2020
LCOBALT
� GEOSCIENCES
March 25, 2020
Troy Grasseth
G2 Contracting
G2contractingalive.com
RE: Retaining Wall & Excavation Considerations
Proposed Single -Family Residence
15712 — 72nd Avenue West
Edmonds, Washington
Cobalt Geosciences, LLC
P.O. Box 82243
Kenmore, Washington 98028
In accordance with your authorization, Cobalt Geosciences, LLC has prepared this letter to
discuss free-standing retaining wall construction east of the proposed residence at the referenced
site. This letter follows our receipt and review of a third -party review letter by Landau Associates
dated February 19, 202o as well as a recent site visit to observe the current site topography. Their
letter discusses a previous 20 feet tall cut and not the 12 to 14 feet tall cut as described to us
during our previous site visit.
Observations and Recommendations
We recently visited the site to observe the current topography. Based on our review, it appears
that the proposed lo, feet tall concrete retaining wall east of the residence will be situated on
buttress fill. We estimate that a 1-5H:1V (horizontal to vertical) temporary slope can be created
safely in the buttress fill to allow for construction of the upper retaining wall, provided the wall is
relocated to the west.
Figure i shows the current topography and proposed wall location (original plans and
recommended location), along with location of buttress fill. We added a 1.5H:1V temporary slope
angle to illustrate a possible excavation to allow for basement wall construction and upper
concrete wall construction.
The originally proposed wall location would require steep temporary excavations in buttress fill
that may not be stable. We recommend moving the retaining wall about 8 feet to the west of this
location. This location will allow for wall construction while maintaining a I-511:1V slope in
buttress fill up to 72nd Avenue West.
Since the wall will be situated in fill, we recommend supporting the concrete wall on small
diameter pipe piles driven to refusal in underlying glacial till. The following recommendations
may be used in foundation design considerations for the concrete wall located in the yard area.
The proposed concrete wall may be supported by small diameter driven steel pipe piles extending
to refusal in the underlying dense to very dense native soils.
Pin piles used for foundation support may consist of two, three, or four -inch diameter, Schedule
40 or 8o, galvanized steel pipes. Allowable axial compression capacities Of 3, 6, and lo tons may
be used for these piles, respectively.
www.cobaltgeo.co (2o6) 331-1097
March 25, 2020
Page 2 Of 3
Geotechnical Recommendations
The required pile length in order to develop the recommended pile capacity is expected to vary
depending on the depth of loose/soft soils below the foundation elements. For estimating
purposes, a pile length of about 15 to 25 feet may be anticipated.
Three and four -inch diameter piles are typically installed using small (approximately 650 to 1,100
pound) hammers mounted to an excavator. Refusal criteria is the minimum amount of time (in
seconds) required to achieve one inch of penetration, and it varies with the size of hammer used
for pile driving. Penetration resistance required to achieve the capacities will be determined from
the hammer size.
The following is a summary of typical driving refusal criteria for different hammer sizes that are
commonly used for three and four -inch diameter piles.
Hammer Weight
3" Pile Refusal Criteria
4" Pile Refusal Criteria
Hammer
(lb) / Blows per
(seconds per inch)
(seconds per inch of
minute
penetration)
Hydraulic TB
650/
225
550-1100
12
20
Hydraulic TB
850/
325
550-1100
10
16
Hydraulic TB
1,100/
425
550-1100
6
10
Alternative hammer sizes may be used; however, the contractor should provide adequate
information to verify equivalence and refusal criteria. Pile splices may be made with compression
fitted sleeve pipe couplers (mechanical couplers).
Two inch pin piles are driven with a 140 pound pneumatic hammer. Refusal criteria is 3 cycles of
30 seconds per inch of embedment.
A total Of 3 percent of the pin piles (one pile minimum) should be load tested to verify the design
capacities. All load tests shall be performed in accordance with the procedure outlined in ASTM
D1143. The maximum test load shall be 2 times the design load (i.e. 2 X lo tons = 20 tons).
A representative of the geotechnical engineer shall provide full time observation of pile
installation and testing to verify the driving refusal criteria.
We can provide additional recommendations upon request.
Closure
The information presented herein is based upon professional interpretation utilizing standard
practices and a degree of conservatism deemed proper for this project. We emphasize that this
report is valid for this project as outlined above and for the current site conditions and should not
be used for any other site. The contractor and owner are responsible for project safety, risk to
adjacent properties, and excavation stability.
Sincerely,
www.cobaltgeo.com (2o6) 331-1097
March 25, 2020
Page 3 Of 3
Geotechnical Recommendations
Cobalt Geosciences, LLC
�X IAONY
WA
vs-y��
54896
NAL
Exp. 6/26/2020
Phil Haberman, PE, LG, LEG
Principal
PH/sc
www.cobaltgeo.com (2o6) 331-1097
S�
E
\r
A\
\01
PATIO
— 285'
— 275'
265'
255'
410
194.0
1
RETAINING
WALLS PER
STRUCTUW
PLANS
E)QST j().01
EASMENIr
Section Showing Current and Originally Proposed Wall Location
Proposed Wall at
ProDosed Location
1�_
Le. W.
Proposed SFR
Fill
Presumed
Former Cut
1.5H:1V Slopee Native Glacial
Till
Section Showing Current Layout with Proposed Wall Location West of Original Location
Proposed Wall 72nd Ave. W.
- 285' Location, -8'West of F
---previous Location
- 275' Proposed Finish
Yard Grade
- 265' Fill
- 255'
1.5H:iV Slope Glacial Till
Not to Scale
C=30
Cobalt Geosciences, LLC
P.O. Box 82243
Kenmore, WA 98028
(2o6) 331-1097
www.cobaltgeo.com
cobaltgeo(a)gmail.com
IS SITE STRUCTURES
1 A Division of Kosnik Engineering, PC
Sharma Residence
1571272 d Ave West
Alternate Basement Wall Design
To Allow for Building Construction
City of Edmonds, Washington
Structural Calculations
Awl mop .14k,
744
CONAL
Project No. S- I 9-083B
First Issue 04-15-2020
REVISION
Apr 29 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
1050519 TH Ave SE, Suite B, Everett, WA 98208 * (425) 357-9600 (phone) e-mail: dan@kosnik.com
prcqoot Shoot - 0
Dgft
Job No
DESIGN CRITERIA
FOUNDATION DESIGN:
RETAINING WALL DESIGN 15 BASED ON THE FOLLOWING VALUES AS
PROVIDED IN THE GEOTECHNICAL REPORT BY GEOTECH CONSULTANTS
INC. DATED 01-25-18 & E-MAIL CORRESPONDENCE OF 09-27-19,
ALLOWABLE BEARING PRESSURE: 3,000 PSF
LATERAL EARTH PRESSURES: DRAINED BACKFILL
ACTIVE CONDITION: 35PCF EFW I LEVEL BACKFILL
PASSIVE CONDITION: 30OPCF EFW ULTIMATE
SEISMIC ADDITION: E 8H PSF UNIFORM
�Al URATED SOIL DENSITY: 125 PCF w/ LEVEL BACKFILL
COEFF OF FRICTION: 0,50 ULTIMATE
its Projecd R�%AAr Shoot
tructures Dae
f A DM*Ion of Koenlk Engineering PC Job No
rr,- U, 14 -, T tj.,nA,Ar*,*: lok...U:
r
SITE STRUCTURES
10511 19th Ave SE, Suite C
Everett, WA, (425)-357-9600
Project Shanna Residence
sheet -,'/ Z -�
date 4, 11�- ; 42
prJ. no. S-19-0830
8.71FT RETAINING WALL REINFORCING Active Pressure + Surcharge
H from top
MS
MU
As
Wall thick
8 in
1
20
32
0.001
Concrete cover
1.5 in
2
103
164
0.006
Rebar size
5
3
284
454
0.018
Concrete Strength fc
3000 psi
4
597
956
0.037
5
1079
1727
0.067
Depth to rebar center
6.19
6
1764
2822
0.110
Comp block depth
0.90
7
2687
4299
0.168
8
3883
6212
0.243
9
5387
8618
0.337
10
7233
11573
0.452
11
9458
15133
0.591
12
12096
19354
0.756
13
15182
24291
0.949
EFWa(pcO
35
14
18751
30001
1.172
Surcharge(psf)
100
15
22838
36540
1.428
Soil Density(pco
125
H from top
NIS
Mu
As
LF active
1.6
8.25
4228
6765
0.262
LF surcharge
1.6
6
1764
2822
0.109
Vertical Reinforcing:
bar size: # 5
spacing: 16 " o/c
As
0.23 sq in
Z' 0.11
FootinQ to Wall Dowels:
bar size: # 5
spacing: 8 " o/c As = 0.46 sq in ?! 0.26
tension controlled cracking: p:5 pt: p = 0.0048 pt= 0.0136
development length: 27.4
Extend Dowels: 3.5 ft minimum into wall ---+ go to 3.67 ft
end hook development: 9.6
Embed Dowels: 5.5 in min into footing — go to 9 in into 12 in ftg
Horizontal Reinforcinir
bar size: # 5
spacing: 16 " o/c
each face: no P 0,0024 0.0020
0
J
SITE STRUCTURES Project Sharma Residence sheet 4 /r�
10511 19th Ave SE, Suite C date
Everett, WA, (425)-357-9600 prJ. no. S-19-083P
8.71FT RETAINING WALL REINFORCING Active Pressure + Seismic
Seismic Pressure Component
Uniform Lateral Earth Pressure 8 H psf 66 psf
Load Factor for Seismic Pressure Component 1.00
H from top
MS
MU
As
Wall thick
8 in
1
39
42
0.002
Concrete cover
1.5 in
2
179
207
0.008
Rebar size
5
3
455
549
0.021
Concrete Strength f c
3000 psi
4
901
1125
0.044
5
1554
1992
0.078
Depth to rebar center
6.19
6
2448
3204
0.125
Comp block depth
0.90
7
3618
4818
0,188
8
5099
6891
0.269
9
6926
9477
0.370
10
9133
12633
0.494
11
11757
16416
0.641
12
14832
20880
0.816
13
18393
26082
1,019
14
22475
32079
1.253
15
27113
38925
1.521
EFWa(pcf)
35
Soil Density(pcf)
125
H from top
NIS
MU
As
8.25
5522
7487
0.290
LF active
1.6
6
2448
3204
0.124
Vertical Reinforcine:
bar size: # 5
spacing: 16 " o/c As =
0.23 sq in
0.12
Footing to Wall Dowels:
bar size: # 5
spacing: 8 " o/c As =
0.46 sq in
0.29
tension controlled cracking: p :5 pt: p =
0.0048 pt=
0.0136
development length: 27.4
Extend Dowels: 3.7 R minimum into wall --+ go to
3.67 ft
end hook development: 9.6 11
Embed Dowels: 6.0 in min into footing — go to
9 in into
12 in ftg
SITE STRUCTURES
Project
Sharma Residence
sheet ;? / q
10511 19th Ave SE, Suite C
date 44 11 1'� �Iwp
Everett, WA, (425)-357-9600
prJ. no. S-19-083,1�7
8.71FT RETAINING WALL REINFORCING Active Pressure + Surcharge
Ha(ft)= 9.25
EFWa(pcf)= 35
Tw(in)= 8
Tftg(in)= 12.00
Hp(FT)= 2.00
EFWp(pcf)= 300
Hw(ft)= 8.71
Wftg(ft)= 5.00
FSpassive= 1.00
D(wall)pcf-- 150
Lheel(ft)= 3.00
CoeFrict-- 0.50
Dsoil(pcf)= 125.00
Ltoe(ft)= 1.33
Surchg(pso= 100.00
D(ftg)pcff- 150
W(surchg)= 300
WI(heel)= 3094
Fsrchg(lbs)= 259
Allowalbe Bearing Pressure
3000 psf
W2(wall)= 871
Fa(lbs)= 1497
LF oveturn= 1.5
Fp(lbs)-- 600
Ms-ot(ft-lb)= 5815
W4(ftg)-- 750
Ffrict(lbs)= 2507
Mu-ot(ft-lb)= 8722
Wtotal= 5015
FS sliding= 1.77
FS slide reqd= 1.50
D key(ft)= 0.00
Net Sliding= -1351
Xcw(ft)= 1.97
Ecc-s(ft)= 1. 16
Xresult-s(ft)= 3.13
Tr-s(ft)= 1.87
Ecc-u(ft)= 1.74
Xresult-u(ft)= 3.71
Tr-u(ft)= 1.29
3rd point= 1.67
CASE= Service
RESULTANT WITHIN MIDDLE 3rd
Tr (ft)= 1.87
Lbrg(ft)=
5.00
Ql(psf)=
1758 :5 3000 psf
Q2(psf)=
248
CASE= Ultimate
RESULTANT OUTSIDE MIDDLE 3rd
Tr (ft)= 1.29
Lbrg(ft)=
3.88
Ql(psf)=
2586 :5 1.5 x 3000
4500 psf
Q2(psf)=
0
HEEL REINFORCING DESIGN
Top bar cover (in)= 2
Top bar size =
5
Top bar spacing (in)=
16
Depth to Reinf d (in)=
9.69
Comp, Block a (in)--
0.45
d - a/2 (in)=
9.46
As provided (sq in)=
0.23
TOE REINFORCING DESIGN
Bot bar cover (in)= 3
Load Factor 1.5
Wall Mu= 6343 ft-lbs
Heel Mu based on Wdl
Heel Mu DESIGN=
As reqd =
As min =
1.33 x As reqd =
6222
6222 ft-lbs @ wall
0. 15 sq in per ft
0.39 sq in per ft
0. 19 sq in per ft
Bot bar size =
4
Wall Mu - Heel Mu
121
Bot bar spacing (in)=
16
Toe Mu DESIGN =
150 ft-lbs @ wall
Depth to Reinf d (in)=
8.75
Comp Block a (in)--
0.29
As reqd =
0.00 sq in per ft
d - a/2 (in)=
8.61
As min =
0.35 sq in per ft
As provided (sq in)=
0.15
1.33 x As reqd =
0.0 1 sq in per ft
f SITE STRUCTURES
10511 19th Ave SE, Suite C
Everett, WA, (425)-357-9600
Project Shanna Residence
sheet (P 6
date �-)6 -
pIJ. no. S-19-083J71
8.71FT RETAINING WALL REINFORCING Active Pressure + Seismic
Ha(ft)= 9.25 EFWa(pcf)= 35 Tw(in)= 8 Tftg(in)= 12.00
Hp(FT)= 2.00 EFWp(pcf)= 300 Hw(ft)= 8.71 Wftg(ft)= 5.00
FSpassive= 1.00 D(wall)pcf-- 150 Lheel(ft)= 3.00
CoeFrict-- 0.50 Dsoil(pcf)= 125.00 Ltoe(ft)= 1.33
Wseismic(psf)= 66.00 D(ftg)pcf-- 150
WI(heel)= 3094 F seismic= 611 Allowalbe Bearing Pressure 3000 psf
W2(wall)= 871 Fa(lbs)= 1497 LF oveturn= 1.36
Fp(lbs)= 600 Ms-ot(ft-lb)= 7040
W4(ftg)= 750 Ffrict(lbs)= 2357 Mu-ot(ft-lb)= 9546
Wtotal= 4715
FS sliding= 1.46 FS slide reqd= 1.36 D key(ft)= 0.00
Net Sliding= -850
Xcw(ft)= 2.00 Ecc-s(ft)= 1.49 Xresult-s(ft)= 3.49 Tr-s(ft)= 1.51
Ecc-u(ft)= 2.02 Xresult-u(ft)= 4.02 Tr-u(ft)= 0.98
3rd point7- 1.67
CASE= Service RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 1.51
Lbrg(ft)= 4.5 3
Q I (psf)= 2083 < 3000 psf
Q2(psf)= 0
CASE= Ultimate RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 0.98
Lbrg(ft)= 2.93
Ql(psf)= 3216 :S 1.5 x 3000 = 4500 psf
Q2(psf)= 0
HEEL REINFORCING DESIGN
Top bar cover (in)= 2
Top bar size =
5
Top bar spacing (in)=
16
Depth to Reinf d (in)=
9.69
Comp Block a (in)=
0.45
d - a/2 (in)=
9.46
As provided (sq in)=
0.23
TOE REINFORCING DESIGN
Bot bar cover (in)= 3
Bot bar size = 4
Bot bar spacing (in)= 16
Depth to Reinf d (in)= 8.75
Comp Block a (in)= 0.29
d - a/2 (in)= 8.61
As provided (sq in)= 0.15
Load Factor = 1.5
Wall base Mu= 8282
Heel Mu based on Wdl 5672
Heel Mu DESIGN= 2800 ft-lbs @ wall
As reqd = 0.07 sq in per ft
As min = 0.39 sq in per ft
1.33 x As reqd = 0.09 sq in per ft
Wall Mu - Heel Mu 2610
Toe Mu DESIGN = 2700 ft-lbs @ wall
As reqd = 0.07 sq in per ft
As min = 0.35 sq in per ft
1.33 x As reqd = 0.09 sq in per ft
% ho
tructures
A DMsIbn of Koonlk Engineering PC
7
al
Project Shoat
Job No
a w
�4
M
CAI.
lit
H q 1:
:-OV'
e, �- mt-ll
oy -EDAfo SPECIAL INSPECTION AND TESTING AGREEMENT
46� S1. J%V1 Permit #: BLD 2018-1101
Project: Sharma / STRUCTURAL
Prior to issuance of a permit, thisform must be completed in its entirety and returned to the City for
approval. The completedform must have signatures of acknowledgment by allparties.
DUTIES AND RESPONSIBILITIES
Special Inspection Firm and Special Inspectors:
The Special Inspection firm of
will perform special inspection for the following types of work (separate forms must be submitted if more than
one firm is to be employed):
—X— Reinforced Concrete Spray applied Fireproofing
Bolting in Concrete Smoke Control Systems
Prestressed Concrete Lateral Wood
Shotcrete Structural Observation by design professional
Structural Masonry Grading/soils
—X— Structural Steel/Welding :5V4 Steel Floor and Roof Decks
—X— High Strength Bolting Fwl I Other
'54yuc,4� 4"A 6`( A
All individual inspectors to be employed on this project will be WABO certified for the type of work they are to
inspect. If inspection is for work that is not covered by the WABO categories, or the inspector is not WABO
certified, a detailed resume of the inspector and firm must be submitted. The resume must show that the
inspector and the firm are qualified by education and experience to perform the, work and testing required by the
project design and specifications.
The work shall be inspected for conformance with the plans and specifications approved by the City. Revisions
and addenda sheets will not be used for inspection, unless they have been approved by the City. Inspection
records shall. include:
• A daily record to be maintained on site, itemizing the inspections performed. Any nonconforming work
shall be brought to the immediate attention of the contractor for resolution.
• A weekly report shall be submitted to the City; detailing the inspections and testing performed, listing
any nonconforming work and resolution of nonconforming items.
• A final report shall be submitted to the building department prior to the Certificate of Occupancy being
issued. This report will indicate that inspection and testing was completed in conformance with the
approved plans, specifications and approved revisions or addenda. Any unresolved discrepancies must
be detailed in the final report.
LABUILDING DIVISION FILES\Spmial Inspectiom\Special Inspedion Reparts\Sl Sharma Struc.&0/30/2019
ContrActor.,
The contractor shall provide the special inspector or agency adequate notification of work requiring inspection.
The City approved plan and specifications must be madc available, at the jobsite for the use of the special
inspector and the City inspector. The contractor shall maintain all daily inspection report%, on site, for review by
all parties.
The special inspection functions aii'.considered to be in addition to the normal inspections performed by the City
and the contractor is responsible for contacting the City to schedule regular inspections. No concrete shall be
poured or odier work covered until approval is given by the City inspector.
Building Department-,
The building department shall review any revisions and addenda. The City inspector will monitor the special
inspection functions for compliance with the agreement and the approved plans. The City inspector shall be
responsible for approving various stages of construction to be covered and for work to proceed.
Desipn Professiouals:
The architect and/or engineer will clearly indicate on the plans and specifications the specific types of special
inspection required and shall include a schedule for inspection and testing. The architect andlor engineer will
coordinaW their revision and addenda procuss in such a way as to ensure that all required City approvals are
obtained, prior to work shown on the revisions being performed in the field -
Owner:
The project owner, or the architect or engineer acting as the owners agent, shall employ the special inspector or
agency.
ENFORCEMENT
A failure of the special inspector or firm to perform in keeping with the requirements of the JBC, the approved
plans and this document, may void this agreement and the Building Official's approval of
the special inspector.
In such a case a new special inspector and/or firm would need to be proposed for approval.
A failure of the
design and/or construction parties to perform in accordance with this agreement may result
in a STOP WORK
notice being posted on the project until nonconforming iterns have been resolved,
ACKNOWLEDGMENTS
I have read and agree to comply with the terms and conditio7ns of eement.
4this.
Owner: X, Signature
Date
Contractor: Sijpialure
Date:
ag ae? em
8YAAN7��W__"'
Arch./Eng-__0 Signature(?-/
Date:
iA* I TIA
.Special Insp. 1 IM4 Fly yntu _5.ignature ---Date:
J
Special Insp. Agencya�g
ACCEPTED F THE CITY OF EDMONDS BUILDING DIVISION
By Date-
LARIMMING DIVISION FFITSISVeml lostwdinniNStmeW knxvfJon RcpmAST Shama Svw.dnc97012019
P D
STING AGREEMENT
SPECIAL INSPECTION AND TE
Permit 0: BLD2018-1101
Project: Sharma SFR
Prior to issuance of a permi4 thisform must be completed in its endrety and returned to the CUyfor
approvaL The cooWletedfarm must have signatures of admawledgment by anpardes.
DUTIES AND RESPONSIRIMIES SCANNED
Special Inspection Firin and Special . Inspectors: SEP 0 5 2019
The Special Inspection firm of ecdec C-A-KZ14 J&"h. Tnr. will porform special
inspection for the following tyjx�s of work (separate forms must be submitted if more than one firm is to be
employed):
a Geotechnical Engineer for Soils
All individual inspectors to be employed on this project will be WABO eertified for the type'of work they are to
inspect, If inspection is for work that is not covered by the WABO categories, or the inspector is not WABO
certified, a dotailed resume of the inspector and firm must be submitted. The resume must show that the inspector
and the firm are qualified by education and experience to perform the work and testing required by the project
design and specifications.
The work shall be inspected for conformance with the plans and specifications approved by the City. Revisions
and addenda sheets will not be used for inspection, unless they have been approved by the City. Inspection
records shall include:
A daily record to be maintained on site,, itemizing the inspections performed. Any nonconforming work
shall be brought to the immediate attention of the contractor for resolution.
A weekly report shall be submitted to the City-, detailing the inspections and testing performed, lisfing my
nonconforming work and resolution of nonconforming itzing,
A final report shall be submitted to the building department prior to the Certificate of Occupancy being
issued, This report wiff indicate that inspection and testing was completed in conformance with the
approved plans, specifications and approved revisions. or addenda. Any unresolved discrepancies must be
detailed in the final report.
Contractor:
The contractor shall provide the special inspector or agency adequate notifica6on of work requiring inspection.
The City approved plan and sp'ecifications must be made available, at the jobsite for the use of the special
inspector and the City inspector. The contractor shall maintain all daily inspection reports, on site, for review by
all partles.,
The special inspection funuions are considered to be in addition to the normal inspections performed by the City
and the contractor is responsible for contacting the City to schedule regular inspections, No concrete shall be
poured or other work covered until approval is given by the City inspector.
C:\UsenVnatonGBOTECHNW.OM\AppDateVAcahMimDwMW]ndows\Tanporary lntww� Fltzs\CmtentOialook%RSHVBJT=018-
I 101—Shanna—SFR—(Uiidorbrink)jpeoist—Iiispectloq_form,dooxl/912019
Bitilding Department:
The building department shall review any revisions and addenda. The City inspector wili'monitor the special
hispection functions for compliance with the agreement and the approved plans. Ile City inspector shall be
responsible for approving various stahms of construction to be covered and for work to proceed,
Desian ProfessionRb:
The architect and/or engineer will clearly indicate on the plans and specifications the specific types of special
inspection required and shall include a schedule for inspection and testing. Tbo architect and/or engineer will
coordinate their revision and addenda proms In such a way as to ensure that A required City approvals am
obtained, prior to work shown on the revisions being performed in the field.
Owner:
The project owner, or the architect or engineer acting as the owners agent shall employ the special inspector or
agency,
ENFORCEMEW
A failure of the special inspector or firm to perform. in keeping with the requirements of the IBC, the approved
plans and this document, may void this agreement and the Building Official's approval of the special inspector.
In such a case a now speciafinspector audlor firm would need to be proposed for approval. A failure of the
design and/or construction parties to perform in accordancewith this agreement may result in a STOP WORK
notice being posted on the project until nonconforming items have been resolved.
ACKNOWLEWMENTS
I have read and agree to comply with the terms and conditions of this
Owner
raw 7
Contractor-,
Arch./Eng:
.Signature.
-Date
Date.
Dat6:
Special Insp. J4,
,,, & ignature -Date. 41 -*)JQ
4�&r WArvi
Special Insp. Agency
;ACCEPTMED F CITY OF EDMONDS BUILDING DEPT,
Y. 161 -7%
B- Date: /z7/
C:kUsm\mu=.GEOTECRNW.O=AppDatakLocaAMiormolhVAndowATempomry Internet M1eAContenWuf1ooMHVHJTS\2019-
I 101—Shartna_SFk(UndeTbrink)jpwial_lnqmflon—form.doaxt/9/2019
After Recording Return to:
City Clerk
City of Edmonds
121 5th Avenue N
Edmonds, WA 98020
T
20191021 11
�
:11U.IiTy.
A0Sr11N'GT Nei
A,
NOTICE OF PRESENCE OF CRITICAL AREAS AND/OR
CRITICAL AREAS BUFFERS ON PROPERTY
GRANTOR(S): Amit Sharma & Rajni Mohan
GRANTEE: City of Edmonds, a Washington municipal corporation
Legal Description:
SECTION 05 TOWNSHIP 27 RANGE 04 QUARTER SW MEADOWDALE BEACH
BLK 000 D-1 I LOT I CITY ED SP NO PLN2014-0015 REC AFN 201612095001
BEING A PTN LOTS 24 & 25 EXST PLAT
Assessor's Tax Parcel ID No.: 00513100002411
Reference Number(s) of Related Documents(s): CRA20180002
NOTICE OF PRESENCE OF CRITICAL AREA(S) AND/OR
CRITICAL AREA BUFFER(S) ON PROPERTY
NOTICE IS HEREBY GIVEN this I I -V-+ day of 'TtA uA r�,, 2019, by Amit
Sharma & RaJni Mohan ("Grantor(s)"), as required by Grantee, City of Edmonds, pursuant to
Edmonds Community Development Code (ECDC) 23.40.270.B, that at least one type of critical
area and/or critical areas buffer has been found through field verification to be present on the
Property described in Exhibit A hereto. This notice is being recorded as a condition of issuance
for a development permit related to the property. As part of the permit application review process
it was determined that the following type(s) of critical area and/or critical area buffer(s) were
found to be present on the property:
Slopes on the subject property exceed 40%. The steepness of these slopes classifies
the site as a potential landslide hazard area pursuant to Chapter 23.80 ECDC.
The City of Edmonds has adopted ordinances that regulate this type of critical area and/or
buffer. Prospective purchasers are advised hereby that these regulations may limit the type and/or
location of development or other use that may occur on the property. Please contact the City of
Edmonds for specific information about the applicable critical area regulations.
This notice shall remain on the title records of Snohomish County until released by the
City of Edmonds, which shall only occur if the owner is able to submit a critical areas report to
demonstrate to the City of Edmonds that the critical area designation no longer applies to the
Property. Any release of this notice shall be subject to applicable procedural provisions of the
ECDC.
GRANTOR(S):
By:
Name:
Title (if applicable):
GRANTOR(S):
By:
Name: tL'
Title (if appliAble):
A,
Notary Pu7blic
State of Washington
DANA K MCCALL
My COMMISSION EXPIRES
1
S!Vember 27, 2019
(use this space for notarial stamp/seal)
STATE OF
ss.
COUNTY OF
I certify that I know or have satisfactory evidence that AZr— 5#K94 is the
person who appeared before me, and said person acknowledged that he/she signed this instrument, on oath
stated that he/she was authorized to execute the instrument and acknowledged it as his/her free and voluntary
act for the uses and purposes mentioned in the instrument.
Dated: Ygl �q
Notary Public
Print Name
My commission expires
STATE OF
ss.
COUNTY OF
I certify that I know or have satisfactory evidence that A�9�4 14 is the
person who appeared before me, and said person acknowledged that Ke2fle's—ig'ned this instrument, on oath
stated that he/she was authorized to execute the instrument and acknowledged it as his/her free and voluntary
act for the uses and purposes mentioned in the instrument.
Dated: V31 // q
Notary Public
State of Washington
DANA K MCCALL
I MY COMMISSION EXPIRES
September 27, 2019
space
Notary Public
Print Name
My commission expires 7
1jq
I A
2401 Ift Ave E
OEOTECH SeafflaWashiftgtoft 981U.1
CONSULTANTS, INC. (425) 747-5618
January 25, 2018
JN 18021
Amit Sharma co?'Y
1737A Northwest 60t' Street a7y
Seattle, Washington 98107
via email: amit.sharma@docusign.com
Subject: Geotechnical Engineering Study SE? 2 5 2018
Proposed Single -Family Residence
15712 — 72nd Avenue West
Edmonds, Washington
Our firm has prepared a geotechnical engineering study for the proposed Meadowview Estates
short -plat project dated October 9, 2013. The proposed single-family residence that is under
consideration in this report is on a lot located in the northeastern corner of the short -plat. This
report relies on the information contained in the study for the short -plat property, and provides
geotechnical engineering design parameters for the new residence proposed on the subject lot.
We understand that a residence is proposed in the upper, eastern portion of the site, adjacent to
the west side of 72nd Avenue West. The lot slopes gently to moderately down to the west from the
street. It appears that the residence will have a main level near the street grade, and a basement
level that daylights to the west. We understand that some retaining walls are proposed on the lot
outside of the residence, likely on the more western, downslope portion.
If the scope of the project changes from what we have described above, we should be provided
with revised plans in order to determine if modifications to the recommendations and conclusions of
this report are warranted.
SITE CONDITIONS
SURFACE
The Vicinity Map, Plate 1, illustrates the general location of the site in the Meadowdale area of
Edmonds. The subject lot is adjacent to the western, downslope edge of 721 Avenue West. The
site is mostly undeveloped, forested, and slopes gently to moderately downward to the
west/southwest. However, an approximate 50 percent slope was graded on the western edge of
the lot in the last few years in order to install a street within the Meadowdale Estates short -plat
property; the paved street is now located at the base of this graded slope. This slope is covered
with grass. We made a recent site visit, and we did not observe any indications of instability of the
graded slope of natural slopes on the site.
Per ECDC 23.80.020A based on soil conditions, any slope on the site that is greater than 15
percent is considered an Erosion Hazard Area. There are several areas that are steeper than 15
percent on the site. The only area on the site that is greater than 40 percent is on the western edge
where the street excavation was made as noted above. However, per ECDC 23.80.020.13, these
slope is considered to be a Landslide Hazard Area.
GEOTECH CONSULTANTS, tNC.
I ,
Sharma JN 18021
January 25, 2018 Page 2
SUBSURFACE
Several test pits and test borings were done on throughout the short -plat property in prior to our
2013 study. Two test pits were excavated on the subject lot, while a third test pit was just to the
west. In addition, a test boring was just southwest of the lot. The approximate locations of these
explorations, which were known as Test Pits 5, 6, and 7, and Test Boring 3, are shown on the Site
Exploration Plan, Plate 1. The logs of these previous test pits and boring are attached to this report.
The soil - revealed in the upper po * rtion of these explorations is native sand, with the first 2 to 3 feet
being loose to medium -dense. Then the sand became dense — which was revealed to the bottom of
the test pit of approximately 5 feet. In the nearby test boring, this dense sand was underlain at
approximately 8 feet by medium -dense silty sand. At a depth of approximately 24 feet, again dense
sand was revealed. The test boring was drilled to a maximum explored depth of approximately 26.5
feet.
The stratification lines on the logs represent the approximate boundaries between soil types at the
exploration locations. The actual transition between soil types may be gradual, and subsurface
conditions can vary between exploration locations. The logs provide specific subsurface information
only at the locations tested. Where If a transition in soil type occurred between samples in the
borings, the depth of the transition was interpreted. The relative densities and moisture descriptions
indicated on the test pit and boring logs are interpretive descriptions based on the conditions
observed during excavation and drilling.
CONCLUSIONS AND RECOMMENDATIONS
GENERAL
THIS SECTION CONTAINS A SUMMARY OF OUR STUDY AND FINDINGS FOR THE
PURPOSES OF A GENERAL OVERVIEW ONLY MORE SPECIFIC RECOMMENDATIONS AND
CONCLUSIONS ARE CONTAINED IN THE REMAINDER OF THIS REPORT. ANY PARTY
RELYING ON THIS REPORT SHOULD READ THE ENTIRE DOCUMENT.
Several test pits and borings were conducted on the short -plat property as noted in our 2013 study,
with several on or near the subject lot. These explorations encountered dense sand soils at shallow
depths. These soils are very competent for supporting building loads, and thus conventional
footings that bear on this competent soil can be used as the foundation of the new residence.
These soils also have high shear strength against slope instability. We understand that in addition
to the residence, retaining walls are proposed on the site in order to provide some level areas on
the site. The onsite sand soils are also very suitable to support the new retaining walls.
Based on ECDC 23.80.070.A.2, "buffer requirements shall be ... consistent with recommendations
provided in the geotechnical report to eliminate or minimize the risk of property damage, death, or
injury resulting from landslides caused in whole or part by activities within the buffer area, based
upon review of and concurrence with a critical areas report prepared by a qualified professional". It
is our professional opinion that no buffers are needed because: 1) most of the site slopes are less
than 30 percent, the western slope that is about 50 percent was graded as part of the Meadowdale
Estates development, and 3) the site soils are very competent at shallow depth.
An "alteration" is needed per Edmonds Code for this project because of the lack of buffers (noted
above) and because development is proposed on Erosion and Landslide Hazard Areas on the site.
GEOTECH CONSULTANTS, INC.
I
Sharma JN 18021
January 25, 2018 Page 3
Based on ECDC-23.80.060A, an alteration to a Landslide Hazard Area and associated buffer may
occur for activities that:
I . Will not increase the threat of the geologic hazard to adjacent properties beyond
preclevelopment conditions;
2. Will not adversely affect other critical areas;
3. Are designed so that the hazard to the project is eliminated or mitigated to a level equal
to or less that predevelopment conditions; and
4. Are certified. as safe as designed and under anticipated conditions by a qualified
engineer licensed in the State of Washington.
In addition, ECDC 23.80.070.A.3 indicates that alterations of a Landslide Hazard Area and
buffer may occur for activities for which a hazards analysis is submitted and certifies that:
1. The development will not increase surface water discharge or sedimentation to adjacent
properties beyond predevelopment conditions;
2. The development will not decrease slope stability on adjacent properties; and
3. Such alterations will not adversely impact other critical areas.
It is our professional opinion the alteration is appropriate because all of these criterial is met,
provided the recommendations in this report are followed and the stormwater from the site is
connected to the stormwater system of Meadowdale Estates (as is planned). We strongly believe
that this development can be done safe and development will be as stable as the current
conditions. It will not affect adjacent properties from a geotechnical engineering standpoint.
As noted earlier, the area on the site are considered Erosion Hazard Areas per the ECDC.
However, we point out that potential erosion hazards on sites such as this only occur only during
construction when the existing vegetation is removed and prior to placing buildings, and
hardscaping and landscaping features. Thus, during construction, erosion control measures are
needed to mitigate the potential for erosion. For this project, we recommend that a silt fence will be
needed around the downslope sides of any cleared areas. Existing ground cover should be left in
place wherever possible to minimize the amount of exposed soil. Rocked staging areas and
construction access roads should be provided to reduce the amount of soil or mud carried off the
property by trucks and equipment. Wherever possible, the access roads should follow the
alignment of planned pavements. Trucks should not be allowed to drive off of the rock -covered
areas. Cut slopes and soil stockpiles should be covered with plastic during wet weather. Following
clearing or rough grading, it may be necessary to mulch or hydroseed bare areas that will not be
immediately covered with landscaping or an impervious surface. On most construction projects, it is
necessary to periodically maintain or modify temporary erosion control measures to address
specific site and weather conditions.
The drainage and/or waterproofing recommendations presented in this report are intended only to
prevent active seepage from flowing through concrete walls or slabs. Even in the absence of active
seepage into and, beneath structures, water vapor can migrate through walls, slabs, and floors from
the surrounding soil, and can even be transmitted from slabs and foundation walls due to the
concrete curing process. Water vapor also results from occupant uses, such as cooking and
bathing. Excessive water vapor trapped within structures can result in a variety of undesirable
conditions, including, but not limited to, moisture problems with flooring systems, excessively moist
air within occupied areas, and the growth of molds, fungi, and other biological organisms that may
be harmful to the health of the occupants. The designer or architect must consider the potential
vapor sources and likely occupant uses, and provide sufficient ventilation, either passive or
GEOTECH CONSULTANTS, INC.
I
Sharma JN 18021
January 25, 2018 Page 4
mechanical, to prevent a buildup of excessive water vapor within the planned structure. Geotech
Consultants, Inc. should be allowed to review the 'final development plans to verify that the
recommendations presented in this report are adequately addressed in the design. Such a plan
review would be additional work beyond the current scope of work for this study, and it may include
revisions to our recommendations to accommodate site, development, and geotechnical
constraints that become more evident during the review process. We recommend including this
report, in its entirety, in the project contract documents. This report should also be provided to any
future property owners so they will be aware of our findings and recommendations.
Geotech- Consultants, Inc. should be allowed to review the final development plans to verify that the
recommendations presented in this report are adequately addressed in the design. Such a plan
review would be additional work beyond the current scope of work for this study, and it may include
revisions to our recommendations to accommodate site, development, and geotechnical
constraints that become more evident during the review process.
We recommend including this report, in its entirety, in the project contract documents. This report
should also be provided to any future property owners so they will be aware of our findings and
recommendations.
SEISMIC CONSIDERATIONS
In accordance with the International Building Code (113C), the site class within 100 feet of the
ground surface is best represented by Site Class Type D (Stiff Soil Class). As noted in the USGS
website, the mapped spectral acceleration value for a 0.2 second (S5) and 1.0 second period (Si)
equals 1.33g and 0.52g, respectively.
The site soils are not susceptible to seismic liquefaction during a large earthquake because of their
dense nature and/or the absence of near -surface groundwater.
CONVENTIONAL FOUNDATIONS
The proposed residence and the retaining walls can be supported on conventional continuous and
spread footings bearing on undisturbed, dense, native sand soil or medium -dense . silty sand
revealed below the dense sand. We recommend that continuous and individual spread footings
have minimum widths of 16 and 24 inches, respectively. Exterior footings should also be bottomed
at least 18 inches below -the lowest adjacent finish ground surface for protection against frost and
erosion. -The local building codes should be reviewed to determine if different footing widths or
embedment depths are required. Footing subgrades must be cleaned of loose or disturbed soil
prior to pouring concrete. Depending upon site and equipment constraints, this may require
removing the disturbed soil by hand.
An allowable bearing pressure of 3,000 pounds per square foot (psf) is appropriate for footings
supported on the competent native sand soils. A one-third increase in this design bearing pressure
may be used when considering short-term wind or seismic loads. For the above design criteria, it is
anticipated that the total post -construction settlement of footings founded on competent native soil
will be about one-half inch, with differential settlements on the order of one-half inch in a distance
of 50 feet along a continuous footing with a uniform load.
GEOTECH CONSULTANTS, INC.
Sharma JN 18021
January 25, 2018 Page 5
Lateral loads due to wind or seismic forces may be resisted by friction between the foundation and
the bearing soil, or by passive earth pressure acting on the vertical, embedded portions of the
foundation. For the latter condition, the foundation must be either poured directly against relatively
level, undisturbed soil or be surrounded by. level, well -compacted fill. We recommend using the
following ultimate values for the foundation's resistance to lateral loading:
PyUZATMETER ITIMNIATE
VALUE
Coeffici. nt of Friction 0.50
Passive Earth Pressure 300 pcf
Where: pcf is Pounds per Cubic Foot, and Passive Earth
Pressure is computed using the Equivalent Fluid Density.
If the ground in front of a foundation is loose or sloping, the passive earth pressure given above will
not be appropriate. We recommend maintaining a safety factor of at least 1.5 for the foundation's
resistance to lateral loading, when using the above ultimate values.
FOUNDA TiON AND RETAINING WALLS
Retaining walls backfilled on only one side should be designed to resist the lateral earth pressures
imposed by the soil they retain. The following recommended parameters are for walls that restrain
level backfill: .
Active Earth Pressure
35 pcf
Passive Earth Pressure
300 pcf
Coefficient of Friction
0.50
Soil Unit Weight
130 pcf
Where: pcf is Pounds per Cubic Foot, and Active and Passive
Earth Pressures are computed using the Equivalent Fluid
Pressures.
* For a restrained wall that cannot deflect at least 0.002 times Its
height, a uniform lateral pressure equal to 10 psf times the height
of the wall should be added to the above active equivalent fluid
pressure.
The design values given above do not include the effects of any hydrostatic pressures behind the
walls and assume that no surcharges, such as those caused by slopes, vehicles, or adjacent
foundations will be exerted on the walls. If these conditions exist, those pressures should be added
to the above lateral soil pressures. Where sloping backfill is desired behind the walls, we will need
to be given the wall dimensions and the slope of the backfill in order to provide the appropriate
design earth pressures. The surcharge due to traffic loads behind a wall can typically be accounted
for by adding a uniform pressure equal to 2 feet multiplied by the above active fluid density. Heavy
construction equipment should not be operated behind retaining and foundation walls within a
distance equal to the height of a wall, unless the walls are designed for the additional lateral
pressures resulting from the equipment. The values given above are to be used to design only
permanent foundation and retaining walls that are to be backfilled, such as conventional walls
GEOTECH CONSULTANTS, INC.
Sharma
January 25, 2018
JN 18021
Page 6
constructed of reinforced concrete or masonry. It is not appropriate to use the above earth
pressures and soil unit weight to back -calculate soil strength parameters for design of other types
of retaining walls, such as soldier pile, reinforced earth, modular or soil nail walls. We can assist
with design of these types of walls, if desired. The passive pressure given is appropriate only for a
shear key poured directly against undisturbed native soil, or for the depth of level, well -compacted
fill placed in front of a retaining or foundation wall. The values for friction and passive resistance
are ultimate values and do not include a safety factor. Restrained wall soil parameters should be
utilized for a distance of 1.5 times the wall height from corners or bends in the walls. This is
intended to reduce the amount of cracking that can occur where a wall is restrained by a corner.
Wall Pressures Due to Seismic Forces
The surcharge wall loads that could be imposed by the design earthquake can be modeled
by adding a uniform lateral pressure to the above-recorn mended active pressure. The
recommended surcharge pressure is 8H pounds per square foot (psf), where H is the
design retention height of the wall. Using this increased pressure, the safety factor against
sliding and overturning can be reduced to 1.2 for the seismic analysis.
Retaining Wall Backfill and Waterproofing
Backfill placed behind retaining or foundation walls should be coarse, free -draining
structural fill containing no organics. This backfill should contain no more than 5 percent silt
or clay particles and have no gravel greater than 4 inches in diameter. The percentage of
particles passing the No. 4 sieve should be between 25 and 70 percent. If the native sand is
used as backfill, a drainage composite similar to Miradrain 6000 should be placed against
the backfilled retaining walls. The drainage composites should be hydraulically connected to
the foundation drain system. The later section entitled Drainage Considerations should
also be reviewed for recommendations related to subsurface drainage behind foundation
and retaining walls.
The purpose of these backfill requirements is to ensure that the design criteria for a
retaining wall are not exceeded because of a build-up of hydrostatic pressure behind the
wall. Also, subsurface drainage systems are not intended to handle large volumes of water
from surface runoff. The top 12 to 18 inches of the backfill should consist of a compacted,
relatively impermeable soil or topsoil, or the surface should be paved. The ground surface
must also slope away from backfilled walls to reduce the potential for surface water to
percolate into the backfill. Water percolating through pervious surfaces (pavers, gravel,
permeable pavement, etc.) must also be prevented from flowing toward walls or into the
backfill zone. The compacted subgrade below pervious surfaces and any associated
drainage layer should therefore be sloped away. Alternatively, a membrane and subsurface
collection system could be provided below a pervious surface. It is critical that the wall
backfill be placed in lifts and be properly compacted, in order for the above -recommended
design earth pressures to be appropriate. The wall design criteria assume that the backfill
will be well -compacted in lifts no thicker than 12 inches. The compaction of backfill near the
walls should be accomplished with hand -operated equipment to prevent the walls from
being overloaded by the higher soil forces that occur during compaction. The section
entitled General Earthwork and Structural Fill contains additional recommendations
regarding the placement and compaction of structural fill behind retaining and foundation
walls.
GEOTECH CONSULTANTS, INC.
Sharma
January 25, 2018
JN 18021
Page 7
The above recommendations are not intended to waterproof below -grade walls, or to
prevent the formation of mold, mildew or fungi in interior spaces. Over time, the
performance of subsurface drainage systems can degrade, subsurface groundwater flow
patterns can change, and utilities can break or develop leaks. Therefore, waterproofing
should be provided where future seepage through the walls is not acceptable. This typically
includes limiting cold -joints and wall penetrations and using bentonite panels or membranes
on the outside of the walls. There are a variety of different waterproofing materials and
systems, which should be installed by an experienced contractor familiar with the
anticipated construction and subsurface conditions. Applying a thin coat of asphalt emulsion
to the outside face of a wall is not considered waterproofing and will only help to reduce
moisture generated from water vapor or capillary action from seeping through the concrete.
As with any project, adequate ventilation of basement and crawl space areas is important to
prevent a buildup of water vapor that is commonly transmitted through concrete walls from
the surrounding soil, even when seepage is not present. This is appropriate even when
waterproofing is applied to the outside of foundation and retaining walls. We recommend
that you contact an experienced envelope consultant if detailed recommendations or
specifications related to waterproofing design or minimizing the potential for infestations of
mold and mildew are desired.
The General, Slabs -On -Grade, and Drainage Considerations sections should be reviewed
for additional recommendations related to the control of groundwater and excess water
vapor for the anticipated construction.
SLABS -ON -GRADE
The building floors can be constructed as slabs -on -grade atop firm, native, non -organic sand or on
structural fill. The subgrade soil must be in a firm, non -yielding condition at the time of slab
construction or underslab fill placement. Any soft areas encountered should be excavated and
replaced with select, imported structural fill.
Even where the exposed soils appear dry, water vapor will tend to naturally migrate upward through
the soil to the new constructed space above it. This can affect moisture -sensitive flooring, cause
imperfections or damage to the slab, or simply allow excessive water vapor into the space above
the slab. All interior slabs -on -grade should be underlain by a capillary break drainage layer
consisting of a minimum 4-inch thickness of clean gravel or crushed rock that has a fines content
(percent passing the No. 200 sieve) of less than 3 percent and a sand content (percent passing the
No.4 sieve) of no more than 10 percent. Pea gravel or crushed rock are typically used for this layer.
As noted by the American Concrete Institute (ACI) in the Guides for Concrete Floor and Slab
Structures, proper moisture protection is desirable immediately below any on -grade slab that will be
Covered by tile, wood, carpet, impermeable floor coverings, or any moisture -sensitive equipment or
products. ACI also notes that vapor retarders such as 6-mil plastic sheeting have been used in the
past but are now recommending a minimum 10-mil thickness for better durability and long term
performance. A vapor retarder is defined as a material with a permeance of less than 0.3 perms, as
determined by ASTM E 96. It is possible that concrete admixtures may meet this specification,
although the manufacturers of the admixtures should be consulted, Where vapor retarders are
used under slabs, their edges should overlap by at least 6 inches and be sealed with adhesive
tape. The sheeting should extend to the foundation walls for maximum vapor protection. If no
potential for vapor passage through the slab is desired, a vapor barrier should be used. A vapor
barrier, as defined by ACI, is a product with a water transmission rate of 0.01 perms when tested in
GEOTECH CONSULTANTS, INC.
Sharma JN 18021
January 25, 2018 Page 8
accordance with ASTM E 96. Reinforced membranes having sealed overlaps can meet this
requirement.
In the recent past, ACI (Section 4.1.5) recommended that a minimum of 4 inches of well -graded
compactable granular material, such as a 5/8-inch-minus crushed rock pavement base, be placed
over the vapor retarder or barrier for their protection, and as a "blotter' to aid in the curing of the
concrete slab. Sand was not recommended by ACI for this purpose. However, the use of material
over the vapor retarder is controversial as noted in current ACI literature because of the potential
that the protection/blotter material can become wet between the time of its -placement and the
installation of the slab. If the material is wet prior to slab placement, which is always possible in the
Puget Sound area, it could cause vapor transmission to occur up through the slab in the future,
essentially destroying the purpose of the vapor barrier retarder. Therefore, if there is a potential
that the p rote ctio n/blotter material will become wet before the slab is installed, ACI now
recommends that no protection/blotter material be used. However, ACI then recommends that,
because there is a potential for slab curl due to the loss of the blotter material, joint spacing in the
slab be reduced, a low shrinkage concrete mixture be used, and "other measures" (steel
reinforcing, etc.) be used. ASTM E-1643-98 "Standard Practice for Installation of Water Vapor
Retarders Used in Contact with Earth or Granular Fill Under Concrete Slabs" generally agrees with
the recent ACI literature. We recommend that the contractor, the project materials engineer, and
the owner discuss these issues and review recent ACI literature and ASTM E-1643 for installation
guidelines and guidance on the use of the protection/blotter material.
The General, Permanent Foundation and Retaining Walls, and Drainage Considerations
sections should be reviewed for additional recommendations related to the control of groundwater
and excess water vapor for the anticipated construction.
EXCA VA TiONS AND SLOPES
Excavation slopes should not exceed the limits specified in local, state, and national government
safety regulations. Temporary cuts to a depth of about 4 feet may be attempted vertically in
unsaturated soil, if there are no indications of slope instability. However, vertical cuts should not be
made near property boundaries, or existing utilities and structures. Based upon Washington
Administrative Code (WAC) 296, Part N, the soil at the subject site would generally be classified as
Type B. Therefore, temporary cut slopes greater than 4 feet in height should not be excavated at
an inclination steeper than 1: 1 (Horizontal:Vertical), extending continuously between the top and
the bottom of a cut.
The above-recom mended temporary slope inclination is based on the conditions exposed in our
explorations, and on what has been successful at other sites with similar soil conditions. It is
possible that variations in soil and groundwater conditions will require modifications to the
inclination at which temporary slopes can stand. Temporary cuts are those that will remain
unsupported for a relatively short duration to allow for the construction of foundations, retaining
walls, or utilities. Temporary cut slopes should be protected with plastic sheeting during wet
weather. It is also important that surface runoff be directed away from the top of temporary slope
cuts. Cut slopes should also be backfilled or retained as soon as possible to reduce the potential
for instability. Please note that sand can cave suddenly and without warning. Excavation,
foundation, and utility contractors should be made especially aware of this potential danger. These
recommendations may need to be modified if the area near the potential cuts has been disturbed in
the past by utility installation, or if settlement -sensitive utilities are located nearby.
GEOTECH CONSULTANTS, INC.
Sharma JN 18021
January 25, 2018 Page 9
All permanent cuts into native soil should be inclined no steeper than 2:1 (H:V). Compacted fill
slopes should also not be constructed with an inclination greater than 2:1 (H:V). To reduce the
potential for shallow sloughing, fill must be compacted to the face of these slopes. This can be
accomplished by overbuilding the compacted fill and then trimming it back to its final inclination.
Adequate compaction of the slope face is important for long-term stability and is necessary to
prevent excessive settlement of patios, slabs, foundations, or other improvements that may be
placed near the edge of the slope.
Water should not be allowed to flow uncontrolled over the top of any temporary or permanent
slope. All permanently exposed slopes should be seeded with an appropriate species of vegetation
to reduce erosion and improve the stability of the surficial layer of soil.
DRAINAGE CONSIDERATIONS
Footing drains should be used where: (1) Crawl spaces or basements will be below a structure; (2)
A slab is below the outside grade; or, (3) The outside grade does not slope downward from a
building. Drains should also be placed at the base of all earth -retaining walls. These drains should
be surrounded by at least 6 inches of 1-inch-minus, washed rock that is encircled with non -woven,
geotextile filter fabric (Mirafi 140N, Supac 4NP, or similar material). At its highest point, a
perforated pipe invert should be at least 6 inches below the bottom of a slab floor or the level of a
crawl space. The discharge pipe for subsurface drains should be sloped for flow to the outlet point.
Roof and surface water drains must not discharge into the foundation drain system. See Plate 2 for
other recommendations regarding subsurface drains.
As a minimum, a vapor retarder, as defined in the Slabs -On -Grade section, should be provided in
any crawl space area to limit the transmission of water vapor from the underlying soils. Crawl space
grades are sometimes left near the elevation of the bottom of the footings. As a result, an outlet
drain is recommended for all crawl spaces to prevent an accumulation of any water that may
bypass the footing drains. Providing even a few inches of free draining gravel underneath the vapor
retarder limits the potential for seepage to build up on top of the vapor retarder.
The excavation and site should be graded so that surface water is directed off the site and away
from the tops of slopes. Water should not be allowed to stand in any area where foundations,
slabs, or pavements are to be constructed. Final site grading in areas adjacent to the residence
should slope away at least 2 percent, except where the area is paved. Surface drains should be
provided where necessary to prevent ponding of water behind foundation or retaining walls. A
discussion of grading and drainage related to pervious surfaces near walls and structures is
contained in the Foundation and Retaining Walls section. Water from roof, storm water, and
foundation drains should not be discharged onto slopes; it should be tight lined to a suitable outfall
located away from any slopes.
GENERAL EARTHWORK AND STRUCTURAL FILL
All building and pavement areas should be stripped of surface vegetation, topsoil, organic soil, and
other deleterious material. The stripped or removed materials should not be mixed with* any
materials to be used as structural fill, but they could be used in non-structural areas, such as
landscape beds. The onsite sand soils can be used as structural fill provided they do contain
organics and are in a moist condition.
GEOTECH CONSULTANTS, INC.
Sharma JN 18021
January 25, 2018 Page 10
Structural fill is defined as any fill, including utility backfill, placed under, or close to, a building,
behind permanent retaining or foundation walls, or in other areas where the underlying soil needs
to support loads. All structural fill should be placed in horizontal lifts with a moisture content at, or
near, the optimum moisture content. The optimum moisture content is that moisture content that
results in the greatest compacted dry density. The moisture content of fill is very important and
must be closely controlled during the filling and compaction process. The allowable thickness of the
fill lift will depend on the material type selected, the compaction equipment used, and the number
of passes made to compact the lift. The loose lift thickness should not exceed 12 inches. We
recommend testing the fill as it is placed. If the fill is not sufficiently compacted, it can be
recompacted before another- lift is plac ed. This -eliminates the need t . o remove the fill to achieve the
required compaction. Fills placed on sloping ground should be keyed into the competent soils. This
is typically accomplished by placing and compacting the structural fill on level benches that are cut
into the competent soils.
The following table presents recommended relative compactions for structural fill:
Where: Minimum Relative Compaction is the ratio, expressed in
percentages, of the compacted dry density to the maximum dry
densit)6 as determined in accordance with ASTM Test
Designation D 1557-91 (Modified Proctor).
LIMITATIONS
The conclusions and recommendations contained in this report are based on site conditions as they
existed at the time of our explorations and assume that the soil and groundwater conditions
encountered in earlier explorations on and near the subject site are representative of subsurface
conditions on the site. If the subsurface conditions encountered during construction are significantly
different from those observed in our explorations, we should be advised at once so that we can
review these conditions and reconsider our recommendations where necessary. Unanticipated
conditions are commonly encountered on construction sites and cannot be fully anticipated by
merely taking samples in explorations. Subsurface conditions can also vary between exploration
locations. Such unexpected conditions frequently require making additional expenditures to attain a
properly constructed project. It is recommended that the owner consider providing a contingency
fund to accommodate such potential extra costs and risks. This is a standard recommendation for
all projects.
This report has been prepared for the exclusive use of Amit Sharma and his representatives for
specific application to this project and site. Our conclusions and recommendations are professional
opinions derived in accordance with our understanding of current local standards of practice, and
within the scope of our services. No warranty is expressed or implied. The scope of our services
does not include services related to construction safety precautions, and our recommendations are
not intended to direct the contractor's methods, techniques, sequences, or procedures, except as
specifically described in our report for consideration in design. Our services also do not include
GEOTECH CONSULTANTS, INC.
Sharma JN 18021
January 25, 2018 Page I I
assessing or minimizing the potential for biological hazards, such as mold, bacteria, mildew and
fungi in either the existing or proposed site development.
ADDITIONAL SERVICES
In addition to reviewing the final plans, Geotech Consultants, Inc. should be retained to provide
geotechnical consultation, testing, and observation services during construction. This is to confirm
that subsurface conditions are consistent with those indicated by our exploration, to evaluate
whether earthwork and foundation construction activities comply with the general intent of the
recommendations presented in this report, and to provide suggesti 6ns for design changes in the
event subsurface conditions differ from those anticipated prior to the start of construction. However,
our work would not include the supervision or direction of the actual work of the contractor and its
employees or agents. Also, job and site safety, and dimensional measurements, will be the
responsibility of the contractor. During the construction phase, we will provide geotechnical
observation and testing services when requested by you or your representatives. Please be aware
that we can only document site work we actually observe. It is still the responsibility of your
contractor or on -site construction team to verify that our recommendations are being followed,
whether we are present at the site or not.
We trust that this letter meets your immediate needs for the proposed development. Please contact
us if we can be of further service.
Respectfully Submitted,
GEOTECH CONSULTANTS, INC.
01/25/18
D. Robert Ward, P.E.
Principal
Attachments: Site Exploration — Plate I
Footing Drain Detail — Plate 2
2013 Test Pits and Boring Logs
DRW:kg
GEOTECH CONSULTANTS, INC.
o'
c 4. v
OF !V WA
U�'0^1 1/ E
T'11?12"svor
L� PROFERIY
CU JEQ�
A-1
Tp 5
"N
(to the\
wiestty�
aim=
A'01;i RX:
'nm
t W
WAIT
SyN21-
-y
io
�M
...........
k",
7-
'Z �-4'
TOM
GEOTECH
CONSULTANTS, INC.
NORTH
tilt
LL
'o'
on.
T
Job No:
Date:
1
Plate:
I
18021
January 20181
No Scale
I I
Slope backfill away from
foundation. Provide surface
drains where necessary.
Back -fill
(See text for
requirements)
Washed Rock
(7/8" min. size)
4" min.
Nonwoven Geotextile
Filter Fabric -
OF-
Tightline Roof Drain
(Do not connect to footing drain)
Possible Slab
4" Perforated Hard PVC Pipe
(Invert at least 6 inches below
slab or crawl space. Slope to
drain to appropriate outfall.
Place holes downward.)
3.",�-. 0 , .;0.' Z,". D ' D ' o . -
0 0-.- . . , 0 .. , - 0 - " , 0
00 0, 0
�fn 0'0 0'0
v,
Vapor Retarder/Barrier and
Capillary Break/Drainage Layer
(Refer to Report text)
NOTES:
(1) In crawl spaces, provide an outlet drain to prevent buildup of water that
bypasses the perimeter footing drains.
(2) Refer to report text for additional drainage, waterproofing, and slab considerations.
GEOTECH
CONSULTANTS, INC.
FOOTING DRAIN DETAIL
15712 - 72nd Avenue West
Edmonds, Washington
Job No: Date: Plate:
18021 1 January 20181 1 2 1
5
10
5
10
TEST PIT 5
Topsoil over;
Description
Brown, slightly silty, gravelly SAND, few organics, loose to moist
-becomes mostly gray, no organics, moist, dense
• Test Pit terminated at 4.0 feet on July 3, 2013.
• No groundwater seepage was observed during excavation.
• No caving observed during excavation.
ox GS
TEST PIT 6
over:
Deschpfion
Gray, very gravelly SAND, coarse grained, medium dense
-becomes dense
• Test Pit terminated at 3.0 feet on July 3, 2013.
• No groundwater seepage was observed during excavation.
• No caving observed during excavation.
GEOTECH
CONSULTANTS, INC.
TEST PIT LOG
15620 72nd Avenue West
Edmonds, Washington
Job Date: Logged by.
13245 1 July 2013 1 D RW I Plate: 5
5
10
'§� ��' TEST PIT 7
Description
FILL Topsoil over;
Brown, slightly silty, gravelly SAND with organics, loose to medium dense
-becomes dense, more gray, no organics
* Test Pit terminated at 4.0 feet on July 3, 2013.
* No groundwater seepage was observed during excavation.
* No caving observed during excavation.
GEOTECH
CONSULTANTS, INC.
TEST PIT LOG
15620 72nd Avenue West
Edmonds, Washington
Job Date: Logged by:
13245 1 July 2013 1 DRW I Plate: 61
BbRING 3.'''
4Y uscs Description
Topsoil
....... Brown/mottled silty, SAND,with7grav�li-ve:ry'-wet,"Ioo
-lens of silt
5 Brown, gravelly SAND, some silt,'coars6-grained,- wet, dense7
1 5014
:sjA
SP
Gray, silty SAND, very fine-grained, w� t,.iliedium-d anse
2 24 1
" r— 1 31 25
20
25
30
35
40
4 20'
5 1
53 1
�1
I
-becomes less silty, moist
:sm
1 1 4
-becomes wet
-lens of silt
:x:
Gray SAND, medium -grained, moist, dense
Test boring was terminated at 26.5 feet below grade on 1-18-97.
Groundwater seepage was'encounteredat 3" during drilling.
GEOTECH
CONSULTAWS, INC.
TEST BORING LOG
15620 - 76TH AVENUE WEST
EDMONDS, WA
Job No., Date., [ogged-Py.
13245 JAN 997 DRW
OEOTECH
CONSULTANTS, INC-
Amit Sharma
1737A Northwest 60th Street
Seattle, Washington 98107
via email. amit.sharma@docusign.com
Subject: Update Letter
Proposed Single -Family Residence
15712 — 72nd Avenue West
Edmonds, Washington
24011 Oth Ave E
Seattle, Washington 98102
(425) 747-5618
December 13, 2018
JN 18021
N,
JAN 2 3 2019
BUILDING DEPARTMENT
CITY OF EDMONDS
We prepared a geotechnical engineering study for the project dated January 25, 2018. In our study,
we noted that dense, native sand soils were revealed at shallow depths, and we recommended that
all footings for the proposed residence and any retaining walls be founded on these soils. We were
recently provided with the plans for the project, and they indicate that all footings will be founded on
the dense soil. The plans also indicate that a relatively flat yard/landscape area will surround the
residence, and that several engineered retaining walls will be needed around the outside of this
area. We believe that the yard/landscape area will be very stable because of the use of the
retaining walls. We understand that there are several trees located in the area of the residence and
the yard/landscape area that are proposed to be removed to for this development. We have been
requested per a City of Edmonds Review Letter to comment on whether it is "safe" to remove the
trees for this development. Our comment regarding this is as follows:
It is our professional opinion from a geotechnical engineering standpoint that, because of
the dense soils and the use of engineered retaining walls as noted above, the removal of
the trees is safe. The retaining walls will provide more stability to the site from a
geotechnical engineering standpoint than the trees because they will be founded on the
dense soils and are engineered.
We trust that this letter meets your immediate needs for the proposed development. Please contact
us if we can be of further service.
DRW:kg
Respectfully submitted,
GEOTECH CONSULTANTS, INC.
D. Robert Ward, P. E.
Principal
12/13/2018
GEOTECH CONSULTANTS. INC.
2401 1 Oth Ave E
OEOTECH Seattle, Washington 98102
CONSULTANTS, INC. (425) 747-5618
December 13, 2018
JN 18021
Amit Sharma
1737A Northwest 60th Street
Seattle, Washington 98107
via email: amit.sharma@docusign.com
Subject: Update Letter
Proposed Single -Family Residence
15712 — 72nd Avenue West
Edmonds, Washington
We prepared a geotechnical engineering study for the project dated January 25, 2018. In our study,
we noted that dense, native sand soils were revealed at shallow depths, and we recommended that
all footings for the proposed residence and any retaining walls be founded on these soils. We were
recently provided with the plans for the project, and they indicate that all footings will be founded on
the dense soil. The plans also indicate that a relatively flat yard/landscape area will surround the
residence, and that several engineered retaining walls will be needed around the outside of this
area. We believe that the yard/landscape area will be very stable because of the use of the
retaining walls. We understand that there are several trees located in the area of the residence and
the yard/landscape area that are proposed to be removed to for this development. We have been
requested per a City of Edmonds Review Letter to comment on whether it is "safe" to remove the
trees for this development. Our comment regarding this is as follows:
It is our professional opinion from a geotechnical engineering standpoint that, because of
the dense soils and the use of engineered retaining walls as noted above, the removal of
the trees is safe. The retaining walls will provide more stability to the site from a
geotechnical engineering standpoint than the trees because they will be founded on the
dense soils and are engineered.
We trust that this letter meets your immediate needs for the proposed development. Please contact
us if we can be of further service.
Respectfully submitted,
GEOTECH CONSULTANTS, INC.
D. Robert Ward, P. E.
Principal
DRW:kg
12/13/2018
RECEIV. EM
DEC 14 2018
DEVELOPWINT SERMES GEOTECH CONSULTANTS, INC.
COLWER
1 4 Il
Wayland, Christina
From: Jared Underbrink <Jared U @cgeng i neeri ng.com >
Sent: Wednesday, September 26, 2018 12:17 PM
To: Amit Sharma; dsidhu@greencloverhomedesigns.com; mike@merithomes.ca
Cc: Chevy Chase
Subject: RE: Details for permit
The surveyor typically gathers all his information on the monuments closest to the site. I doubt there is a closer spot to
go from unless they set one during the construction of the plat. This is what was done for the overall plat. it seems like
your lot being the closest this should be fine with all the information here. It has all the horizontal and vertical
information to tie into the property.
If something else is needed a surveyor would have to do that, but I don't understand what is being requested.
,ji3V
OW422riv 4ACO,
N 4#WVr f ANI arm,57
:r W 02.53. N -
. 1-233-74
FOM Mt W1 'r
& MMM -W AN
IMMST*SW
mom air 26a)
aw W Mau
MFV-271-r- - —arw—
11�� POSMA or
4�r AOT WM D4
su"Ey
(wr ivu)
-7
'aO000
viol
rJCV%' * AOD
?P' , 0009,
OC)6
006*
\—row x
x.]7�4�;
BVM
00071VS193r
..... ... ...
4
IT".
f::AL
ENGIN&RING
Jared Underbrink, PE I Project Manager
250 4th Ave S Ste 200, Edmonds, WA 98020
p. 425.778.8500 1 f. 425.778.5536
www.cgengineering.com
From: Amit Sharma [mailto:amit.sharma@docusign.com]
Sent: Wednesday, September 26, 2018 11:48 AM
To: Jared Underbrink <Jared U@cgengineering.com>; dsidhu@greencloverhomedesigns.com; mike @merithomes.ca
Subject: Re: Details for permit
Jared,
I was able to submit everything to the city yesterday. YAY!
Their one request was to have an updated site plan with a closer datum point.
Is that something you can put together in the next day or two so I can drop off the updated one?
Amit Sharma I Global Account Manager I DocuSign
o: 206.876.69141 m: 425.280.8457 1 docusisEn.com
DOCU5�r-v
From: Jared Underbrink <JaredU2cgengineering.com>
Date: Tuesday, September 18, 2018 at 3:27 PM
To: Amit Sharma <amit.sharmagdocusign.com>, "dsidhuAgreencloverhomedesigns.com"
<dsidhuggreencloverhomedesigns.com>, "mikegmerithomes.ca" <mikeg erithomes.ca>
,,m
Subject: RE: Details for permit
Cad will be attached in a separate email.
4EMINCEE'RENG 120 1997-201.7
Jared Underbrink, PE I Project Manager
250 4th Ave S Ste 200, Edmonds, WA 98020
p. 425.778.8500 1 f. 425.778.5536
www.cgengineerinp,.com
From: Amit Sharma [mailto:amit.sharma@docusign.com]
Sent: Tuesday, September 18, 2018 3:02 PM
To: Jared Underbrink <Jared U @cgengineering.com>; dsidhu@greencloverhomedesigns.com; mike@merithomes.ca
Subject: Details for permit
Jared,
11
Please send Dan your site plan for him to add to his architectural plans and provide whatever is needed for
"Datum Point".
Amit Sharmal Global Account Manager I DocuSign
o: 206.876.6914,1 m: 425.280.8457 1 docusign.com
Chapter 296-155 WAC
Construction Work
Part N
Excavation, Trenching, and Shoring
WAC 296-155-66403 Appendix B-Sloping and benching.
(1) Scope and application. This appendix contains specifications for sloping and benching when
used as methods of protecting employees working in excavations from cave-ins. The requirements
of this appendix apply when the design of sloping and benching protective systems is to be
performed in accordance with the requirements set forth in WAC 296-155-657 (2)(b).
(2) Definitions.
Actual slope. The slope to which an excavation face is excavated.
Distress. Soil that is in a condition where a cave-in is imminent or is likely to occur. Distress is
evidenced by such phenomena as the development of fissures in the face of or adjacent to an open
excavation; the subsidence of the edge of an excavation; the slumping of material from the face or the
bulging or heaving of material from the bottom of an excavation; the spalling of material from the face
of an excavation; and ravelling, i.e., small amounts of material such as pebbles or little clumps of
material suddenly separating from the face of an excavation and trickling or rolling down into the
excavation.
Maximum allowable slope. The steepest incline of an excavation face that is acceptable for the most
favorable site conditions as protection against cave-ins, and is expressed as the ratio of horizontal
distance to vertical rise (H:V).
(3) Requirements.
(a) Soil classification. Soil and rock deposits must be classified in accordance with appendix A
of this Part.
(b) Maximum allowable slope. The maximum allowable slope for a soil or rock deposit must be
determined from Table N- I of this appendix.
(c) Actual slope.
(i) The actual slope must not be steeper than the maximum allowable slope.
(ii) The actual slope must be less steep than the maximum allowable slope, when there are
signs of distress. If that situation occurs, the slope must be cut back to an actual slope
which is at least 1/2 horizontal to one vertical (I /2H: IV) less steep than the maximum
allowable slope.
(iii) When surcharge loads from stored material or equipment, operating equipment, or
traffic are present, a competent person must determine the degree to which the actual
slope must be reduced below the maximum allowable slope, and must ensure that such
reduction is achieved. Surcharge loads from adjacent structures shall be evaluated in
accordance with WAC 296-155-655(9).
(d) Configurations. Configurations of sloping and benching systems must be in accordance with
Figures N- I through N- 18.
Table
N-1
MAXIMUM ALLOWABLE
SOIL OR ROCK TYPE
SLOPES (H:V) P] FOR EXCAVATIONS
LESS THAN 20 FEET DEEP 121
STABLE ROCK
VERTICAL (90')
TYPE A
3/4:1 (53')
TYPE B
1: 1 (45')
TYPE C
1 1/2:1 (34')
Part N, Page 15
Chapter 296-155 WAC
Construction Work
Part N
Excavation, Trenching, and Shoring
NOTES
Ifl: Numbers shown in parentheses next to maximum allowable slopes are angles
expressed in degrees from the horizontal. Angles have been rounded off.
[2]: Sloping or benching for excavations greater than 20 feet deep shall be designed by a
registered professional engineer.
20'Maximum
Figure N-1
Slope Configurations
for Type A Soil
Simple Slope - General
All simple slope excavations 20 feet or less in depth must have a maximum allowable slope of
3/4:1.
Part N, Page 16
A
Chapter 296-155 WAC
Construction Work
Part N
Excavation, Trenching, and Shoring
WAC 296-155-66403 (Cont.)
20'Maximan
Figure N-2
Slope Configurations
for Type A Soil
4'Max.1711,1 3/4
Simple Bench
All benched excavations 20 feet or less in depth must have a maximum allowable slope of 3/4:1
and maximum bench dimensions of 4 feet.
Figure N-3
20'Maximum
4' Max.
4' Max.
Slope Configurations
Multiple Bench
All benched excavations 20 feet or less in depth must have a maximum allowable slope of 3/4:1
and maximum bench dimensions of 4 feet.
Part N, Page 17
Wayland, Christina
From: Amit Sharma <amit.sharma@docusign.com>
Sent: Wednesday, March 25, 2020 8:05 PM
To: Wayland, Christina; Sean Gertz
Cc:
Subject:
Attachments:
Importance:
Follow Up Flag:
Flag Status:
Good Evening Christina and Sean
g2contracting@live.com; Phil Haberman
Re: [EXTERNAL] 15712 72ND AVE W (SHARMA PROJECT)
Updated Geo Letter[3].pdf
High
Follow up
Flagged
Please find stamped updated letter from my Geotech regarding some changes.
After reviewing with our design team, we've decided to change the direction we were going.
We've decided to make the following changes:
0 Add Pin Piles to the wall design to better secure the wall and footings past the loose buttress.
Move the wall 8'further from the road so we can make the slope more in line with 1.51-1:1V slope and give us a
comfortable amount of room to maneuver around safely per our temporary shoring plan.
Because we are moving the wall in 8' further, it will no longer need to be 10' tall, so the footing will also not
need to be as wide.
Moving this wall 8' is a huge sacrifice I am making, but I hope its recognized that it is the right thing to do for everyone
and I hope it shows our desire to work with you and get past all of this quickly.
If there's anything that can be done to expedite/prioritize review of this, I would greatly appreciate it. In parallel, I am
working with my engineers to provide an updated site plan per the changes described here but my thought was, this
letter should provide enough detail to agree with our plan to move forward.
Amit Sharma I Enterprise Account Executive — Healthcare & Life Sciences I DocuSign
rn: 425.280.8457
DocuSign
From: "Wayland, Christina" <Christina.Wayland@edmondswa.gov>
Date: Monday, March 23, 2020 at 4:26 PM
To: Amit Sharma <amit.sharrna@docusign.corn>, "g2contracting@live.com" <g2contracting@live.com>
Subject: FW: [EXTERNAL] 15712 72ND AVE W (SHARMA PROJECT)
Good afternoon Amit,
Please see attached Review letter from our peer consultant.
1-hank you
Christina Wayland
Permit Coordinator
Development Services
City of Edmonds
121 5th Ave North, 2nd floor
Edmonds, WA 98020
(425)771-0220 Ext: 1243
CITY HALL IS CURRENTLY CLOSED TO GENERAL PUBLIC ACCESS. *Development services will continue
to be provided by email or the web and by phone*
Please visit www.edmondswa.gov for up-to-date information on City services.
For Engineering permit inquiries, please email: engineeringpermits@edmondswa.gov
(Planners use planningpermits@edmondswa.gov, Building staff use onlinepermits@edmondswa.gov.
For all other inquiries please email: devserv.admin@edmondswa.go .
Web Map: www.maps.edmoncswa.gov
From: Sean Gertz <SGertz@landauinc.com>
Sent: Friday, March 20, 2020 147 PM
To: Wayland, Christina <Christi na.Wayland @edmondswa.gov>
Cc: Steve Wright <swright@landauinc.com>
Subject: RE: [EXTERNAL] 15712 72ND AVE W (SHARMA PROJECT)
Hello Christina,
Attached is our supplemental geotechnical peer review letter for the proposed residence located at 15712 72 nd Ave W. It
is my understanding that the design team will be taking an additional look at the geometry and/or considering different
wall types to find an appropriate solution. We feel that even though the design may change in the near future, some of
the comments presented in our supplemental peer review letter may still be useful as the design progresses. As always,
please let us know if there are any questions.
Thank you,
Sean Gertz
Landau Associates
COBALT
GEOSCIENCES
Cobalt Geosciences, LLC
P.O. Box 82243
Kenmore, Washington 98028
March 25, 2020
Troy Grasseth
r173)
G2 Contracting
G2contractingalive.com
5
RE: Retaining Wall & Excavation Considerations
BUILDING DEpARTMENT
Proposed Single -Family Residence
C;,Ty oV EDMONDS
15712 — 72nd Avenue West
Edmonds, Washington
In accordance with your authorization, Cobalt Geosciences, LLC has prepared this letter to
discuss free-standing retaining wall construction east of the proposed residence at the referenced
site. This letter follows our receipt and review of a third -party review letter by Landau Associates
dated February 19, 202o as well as a recent site visit to observe the current site topography. Their
letter discusses a previous 20 feet tall cut and not the 12 to 14 feet tall cut as described to us
during our previous site visit.
Observations and Recommendations
We recently visited the site to observe the current topography. Based on our review, it appears
that the proposed lo feet tall concrete retaining wall east of the residence will be situated on
buttress fill. We estimate that a I.5H:lV (horizontal to vertical) temporary slope can be created
safely in the buttress fill to allow for construction of the upper retaining wall, provided the wall is
relocated to the west.
Figure 1 shows the current topography and proposed wall location (original plans and
recommended location), along with location of buttress fill. We added a 1-5H:1V temporary slope
angle to illustrate a possible excavation to allow for basement wall construction and upper
concrete wall construction.
The originally proposed wall location would require steep temporary excavations in buttress fill
that may not be stable. We recommend moving the retaining wall about 8 feet to the west of this
location. This location will allow for wall construction while maintaining a 1.5H:iV slope in
buttress fill up to 72nd Avenue West.
Since the wall will be situated in fill, we recommend supporting the concrete wall on small
diameter pipe piles driven to refusal in underlying glacial till. The following recommendations
may be used in foundation design considerations for the concrete wall located in the yard area.
The proposed concrete wall may be supported by small diameter driven steel pipe piles extending
to refusal in the underlying dense to very dense native soils.
Pin piles used for foundation support may consist of two, three, or four -inch diameter, Schedule
40 or 8o, galvanized steel pipes. Allowable axial compression capacities Of 3, 6, and lo tons may
be used for these piles, respectively.
www.cobaltgeo.co (2o6) 331-1097
March 25, 2020
Page 2 Of 3
Geotechnical Recommendations
The required pile length in order to develop the recommended pile capacity is expected to vary
depending on the depth of loose/soft soils below the foundation elements. For estimating
purposes, a pile length of about 15 to 25 feet may be anticipated.
Three and four -inch diameter piles are typically installed using small (approximately 650 to 1,100
pound) hammers mounted to an excavator. Refusal criteria is the minimum amount of time (in
seconds) required to achieve one inch of penetration, and it varies with the size of hammer used
for pile driving. Penetration resistance required to achieve the capacities will be determined from
the hammer size.
The following is a summary of typical driving refusal criteria for different hammer sizes that are
commonly used for three and four -inch diameter piles.
Hammer Weight
3" Pile Refusal Criteria
4" Pile Refusal Criteria
Hammer
(lb) / Blows per
(seconds per inch)
(seconds per inch of
minute
penetration)
Hydraulic TB
650/
225
550-1100
12
20
Hydraulic TB
850/
325
550-1100
10
16
Hydraulic TB
1,100/
425
550-1100
6
10
Alternative hammer sizes may be used; however, the contractor should provide adequate
information to verify equivalence and refusal criteria. Pile splices may be made with compression
fitted sleeve pipe couplers (mechanical couplers).
Two inch pin piles are driven with a 140 pound pneumatic hammer. Refusal criteria is 3 cycles of
30 seconds per inch of embedment.
A total Of 3 percent of the pin piles (one pile minimum) should be load tested to verify the design
capacities. All load tests shall be performed in accordance with the procedure outlined in ASTM
D1143. The maximum test load shall be 2 times the design load (i.e. 2 X io tons = 20 tons).
A representative of the geotechnical engineer shall provide full time observation of pile
installation and testing to verify the driving refusal criteria.
We can provide additional recommendations upon request.
Closure
The information presented herein is based upon professional interpretation utilizing standard
practices and a degree of conservatism deemed proper for this project. We emphasize that this
report is valid for this project as outlined above and for the current site conditions and should not
be used for any other site. The contractor and owner are responsible for project safety, risk to
adjacent properties, and excavation stability.
Sincerely,
www.cobaltgeo.co (2o6) 331-1097
March 25,2020
Page 3 Of 3
Geotechnical Recommendations
Cobalt Geosciences, LLC
X�"o
N, N"
CA.
54 9
"c GIST EV�, N7
10
Exp. 6/26/2020
Phil Haberman, PE, LG, LEG
Principal
PH/sc
www.cobaltgeo,com (2o6) 331-1097
�42:Zr i�15a
<
N
4
X,
f
I \ " /243A
Section Showing Current and Originally Proposed Wall Location
284.0
—10. MAX H i Section
RETAINING
WALLS PER
STRUCTURAL
PLANS
EXIST 10.0-
T,,,,
EASEMENT'
4�- -- —
— 285' Proposed Wall at 72nd Ave. W.
Proposed Location
— 275' Proposed SFR
265' Fill
Presumed
Former Cut
. . . . ........... .......................................
255' I'll
I.5H:lVSlope" Native Glacial
Till
bection. bnowing uurrent Layout witn Froposea. wall Location west ot uriginal Location
Proposed Wall 72nd Ave. W.
— 285' Location,, -8'WWest of
-Previous Location
— 275' Proposed Finish
Yard Grade
— 265'
Fill
L-1� . .......... . ........................................
— 255'
1.5H:lV Slope Glacial Till
Not to Scale
1"=30'
Cobalt Geosciences, LLC
P.O. Box 82243
Kenmore, WA 98028
(2o6) 331-1097
www.cobaltgeo.com
cobaltgeopgmail.com
Wayland, Christina
From: 13jorback, Leif
Sent: Tuesday, January 7, 2020 12:55 PM
To: 'Amit Sharma'; Wayland, Christina; 'g2contracting@live.com'
Cc: Carter, Eric; Lambert, Jennifer; Akau, Donovan S
Subject: RE: 15712 72ND AVE W, SHARMA � 125
Follow Up Flag: Follow up ;eCetvEV
Flag Status: Completed tl
3 A% 0 7 2020
Amit, wiLoNG
Thank you for submitting your design plans for the site retaining walls and-T mporary shoring. In light of this submittal,
and the fact that conditions on the front portion of your lot and in the right of way have been stabilized, we will consider
the restrictions for work stoppage on your project limited to that portion of work that is not part of your previously
approved plans. Feel free to proceed with the work as you have requested below.
Le�f BjorLcL�
Building Official
City of Edmonds
(42S) 771-0220
Development Services Hours:
Monday & Tuesday 8:00 AM — 4:30 PM
WEDNESDAYS WALK-IN (counter) hours are 8:30-Noon
Thursday & Friday 8:00 AM — 4:30 PM
From: Amit Sharma <amit.sharma@docusign.com>
Sent: Friday, January 3, 2020 5:03 PM
To: Wayland, Christina <Christina.Wayland@edmondswa.gov>;'g2contracting@live.com'<g2contracting@live.com>
Cc: Carter, Eric <Eric.Carter@edmondswa.gov>; Lambert, Jennifer <Jennifer.Lambert@edmondswa.gov>; Bjorback, Leif
<Leif. Bjo rback@ed mondswa.gov>; Akau, Donovan <Do nova n.Aka u @ed mondswa.gov>
Subject: Re: 15712 72ND AVE W, SHARMA
Hello All,
Thanks for meeting with me today at the counter.
As mentioned, while our updated structural/shoring plans are in review for the northeast section of the site plan, we
would like to have the option to work on other areas of the site, that won't affect the area in question.
Specifically, we'd like to work on the retaining wall along the western edge of the site (please see highlighted section
below or attached screen shot). This will definitely save us a lot of time and get us back on track to a somewhat
reasonable timeline to complete the construction.
Please let me know if there are any questions and/or if this would be acceptable to proceed.
P i
T
IZA 0
$ r
Vick
AMI MAI L8 P
PAT-D MUM
Tw
MkN Oft
UOPERFet 27�1
0
WWI
2swa 0 -
N -.1- 45%
"N
LI
NI GAUCI
1.7
1� OnT No
12430 -\I s, 4,
41 Al FASEVNr
Amit Sharma I Enterprise Account Executive — Healthcare & Life Sciences I DocuSign
m: 425.280.8457
DocuSign
From: "Wayland, Christina" <,Christina.Wayland@edmondswa.gov>
Date: Thursday, December 26, 2019 at 7:43 AM
To: Amit Sharma <amit.sharma@docusign.com>, "'g2contracting@live.comill <g2contracting@live.com>
Cc: "Carter, Eric" <Eric.Carter@edmondswa.gov>, "McConnell, Jeanie" <Jeanie. McCon nel I @edmondswa.gov>,
"Lambert, Jennifer" <Jennifer. Lambert@edmondswa.gov>, "Biorback, Leif" <Leif. Biorback@ed mondswa.gov>
Subject: RE: 15712 72ND AVE W, SHARMA
Good morning Amit,
2
If you could bring in everything together, (updated Structural and calcs for the retaining walls and the Shoring), as the
Shoring will need to be approved prior to the retaining walls.
1-hank you
Christina Wayland
Permit Coordinator
Development Services
City of Edmonds
121 5th Ave North, 2nd floor
Edmonds, WA 98020
(425)771-0220
*AS OF 01/01/2017: A 3% SURCHARGE WILL BE ADDED TO ALL CREDIT CARD TRANSACTIONS. THERE IS NO LONGER A
$5,000 TRANSACTION LIMIT.
Development Services Hours:
Monday & Tuesday 8:00 AM — 4:30 PM
WEDNESDAYS WALK-IN (counter) hours are 8:30-Noon
Thursday & Friday 8:00 AM — 4:30 PM
From: Amit Sharma <amit.sharma@docusign.com>
Sent: Friday, Decem be r 20, 2019 9:44 AM
To: Wayland, Christina <Christina.Wayland@edmondswa.gov>; 'g2contracting@live.com'<g2contracting@live.com>
Cc: Carter, Eric <Eric.Carter@edmondswa.gov>; McConnell, Jeanie <Jeanie. McConnell@edmondswa.go >; Lambert,
Jennifer <Jennifer. Lambert@ed mondswa.gov>; l3jorback, Leif <Leif. Biorba ck@ed mondswa.gov>
Subject: Re: 15712 72ND AVE W, SHARMA
Christina,
I have the updated Structural and calculations for the retaining walls, just waiting on the shoring.
Is it worth me bringing in the documents I have or should we just plan on submitting everything together?
Amit Sharma I Enterprise Account Executive — Healthcare & Life Sciences I DocuSign
m: 425.280.8457
DocuSign,
From: "Wayland, Christina" <.Christina.Wayland@edmondswa.gov>
Date: Wednesday, November 27, 2019 at 3:33 PM
To: "'g2contracting@live.com... <g2contracting@live.com>, Annit Sharma <amit.sharma@docusign.com>
Cc: "Carter, Eric" <Eric. Carter@ed mondswa.gov>, "McConnell, Jeanie" <J ea n ie. McConnell @ed mondswa.gov>,
"Lambert, Jennifer" <Jennifer.Lambert@edmondswa.gov>, "13jorback, Leif" <Leif. 134orback@edmondswa.go >
Subject: 15712 72ND AVE W, SHARMA
Good afternoon Troy,
I am getting back to you follow�ng our meeting from yesterday. Like we had discussed, we will need a few additional
items submitted for the temporary shoring. This will be a separate permit from the Single Family Building permit.
*A site plan detailing the areas of temporary shoring, proposed permanent retaining walls and structures.
*Details or plans for the temporary shoring.
*Geotech report (received)
*A Special Inspection Agreement will be required (determined in review)
I have attached the application to submit with your plans.
1-hank you
Christina Wayland
Permit Coordinator
Development Services
City of Edmonds
121 5th Ave North, 2nd floor
Edmonds, WA 98020
(425)771-0220
*AS OF 01/01/2017: A 3% SURCHARGE WILL BE ADDED TO ALL CREDIT CARD TRANSACTIONS. THERE IS NO LONGER A
$5,000 TRANSACTION LIMIT.
Development Services Hours:
Monday & Tuesday 8:00 AM —4:30 PM
WEDNESDAYS WALK-IN (counter) hours are 8:30-Noon
Thursday & Friday 8:00 AM — 4:30 PM
I I
I STRUCTURES
T_
A Division of Kosnik Engineering, PC
Sharma Residence
1571272 d Ave West
Site Retaining Walls
City of Edmonds, Washington
Structural Calculations
Project No. S-1 9-083
First Issue 12-17-19
FaIr, � I � V V
, -D) I � C 8
R Ell � IL", ' *_1 "� 0 L-1 \11",
U
JAN 0 3 R0610
BUILDING DEPARTmEN7
CITY OF EDMONDS
10505 1 9TH Ave SE, Suite 13, Everett, WA 98208 * (425) 357-9600 (phone) * e-mail: dan@kosnik.com
Sv!:o aotko- t(al
I I f
Sharma Residence
Site Retaining Walls
Project No. S-1 9-083
STRUCTURAL CALCULATIONS INDEX
Design Criteria
Sheet
01
10.5ft Retaining Wall Review w/ upward sloped backfill 02-05
10.5ft Retaining Wall Review
w/ level backfill
05-09
8.Oft Retaining Wall Review
w/ level backfill
10-13
5.5ft Retaining Wall Review
w/ level backfill
14-17
3.Oft Retaining Ftg Review
w/ level backfill
18-19
0
4 1 9
sp
Sharma Residence
Site Retaining Walls C-1 -
DESIGN CRITERIA
2015 IBC as adopted by the City of Edmonds, Washington
Foundation Desisin:
Retaining wall design is based on the following values derived from the report
by Geotech Consultants, Inc dated 01-25-18 & e-mail correspondence of
09-27-19.
Allowable Bearing Pressure: 3,000psf
Active Condition
Passive Condition
Seismic Surcharge:
Coefficient of Friction:
Soil Density:
Material Requirements:
35pcf EFW ( level backfill )
55pcfEFW (upwardslope).
300pcf EFW ultimate
E = 8H psf Uniform
Rebar: Grade 60
Concrete: f c= 3500 psi
0.50 ultimate
125 pcf level backfill
135 pcf upward sloped backfill
SITE STRUCTURES
Project
Shanna
sheet
10511 19th Ave SE, Suite C
date
Everett, WA, (425)-357-9600
p�. no.
S-19-083
10.5FT RETAINING WALL REINFORCING
Active Pressure
+ Surcharge
H from top
Ms
Mu
As
Wall thick
10 in
1
9
15
0.000
Concrete cover
2 in
2
73
117
0.004
Rebar size
6
3
-248
396
0.012
Concrete Strength fc
3500 psi
4
587
939
0.029
5
1146
1833
0.057
Depth to rebar center
7.63
6
1980
3168
0.099
Comp block depth
1.11
7
3144
5031
0.157
8
4693
7509
0.234
9
6683
10692
0.333
10
9167
14667
0.457
11
12201
19521
0.609
12
15840
25344
0.790
13
20139
32223
1.005
EFWa(pcf)
55
14
25153
40245
1.255
Surcharge(pso
0
15
30938
49500
1.544
Soil Density(pcf)
135
H from top
Ms
Mu
As
LF active
1.6
10.5
10612
16979
0.534
LF surcharge
1.6
8
4693
7509
0.236
Vertical Reinforcing:
bar size: # 6
spacing: 16 " o/c
As =
0.33 sq in
0.24
Footing to Wall Dowels:
bar size: #6
spacing: 8 " O/c
As =
0.66 sq in 2:
0.53
tension controlled cracking: p :5 pt:
p =
0.0055 pt=
0.0158
development length: 30.4
Extend Dowels: 4.5 ft minimum into wall --+ go to
5 ft
end hook development: 10.6
Embed Dowels: 8.6 in min into footing ---*
go to
I I in into
14 in ftg
Horizontal Reinforcing:
bar size: # 5
spacing: 12 " o/c
each face: no P
0,0026
2: 0.0020
SITE STRUCTURES Project Shanna sheet
10511 19th Ave SE, Suite C date
Everett, WA, (425)-357-9600 prj. no. S-19-083
10.5FT RETAINING WALL REINFORCING Active Pressure + Seismic
Seismic Pressure Component
Uniform Lateral Earth Pressure 8 Hpsf= 84 psf
Load Factor for Seismic Pressure Component 1.00
H from top
Ms
Mu
As
Wall thick
10 in
1
51
57
0.002
Concrete cover
2 in
2
241
285
0.009
Rebar size
6
3
626
774
0.024
Concrete Strength fc
3500 psi
4
1259
1611
0.050
5
2196
2883
0.090
Depth to rebar center
7.63
6
3492
4680
0.146
Comp, block depth
1.11
7
5202
7089
0.221
8
7381
10197
0.318
9
10085
14094
0.440
10
13367
18867
0.588
11
17283
24603
0.767
12
21888
31392
0.979
13
27237
39321
1.226
14
33385
48477
1.512
15
40388
58950
1.839
EFWa(pcf)
55
Soil Density(pcf)
135
H from top
Ms
Mu
As
10.5
15242
21609
0.679
LF active
.1.6
8
7381
10197
0.321
Vertical Reinforcing:
bar size: # 6
spacing: 16 " o/c
As
0.33 sq in
2, 0.32
Footing to Wall Dowels:
barsize: # 6
spacing: 8 " o/c As = 0.66 sq in Z: 0.68
tension controlled cracking: p:5 pt: p = 0.0055 pt= 0.0158
development length: 30.4
Extend Dowels: 5.1 ft minimum into wall --+ go to 5 ft
end hook development: 10.6 "
Embed Dowels: 10.9 in min into footing — go to I I in into 14 in ftg
SITE STRUCTURES Project Sharma sheet
10511 19th Ave SE, Suite C date
Everett, WA, (425)-357-9600 prJ. no. S-19-083
10.5FT RETAINING WALL REINFORCING Active Pressure + Surcharge
Ha(ft)= 11.67 EFWa(pcf)= 55
Tw(in)= 10 Tftg(in)= 14.00
Hp(FT)= 1.50 EFWp(pcf)= 300
Hw(ft)= 10.5 Wftg(ft)= 7.33
FSpassive= 1.50
D(wall)pcf-- 150 Lheel(ft)= 3.50
.
CoeFrict-- 0.50 Dsoil(pco= 135.00
Ltoe(ft)= 3.00
Surchg(psf)= 0.00
D(ftg)pcf�- 150
W(surchg)= 0
WI(heel)= 4963
W2(wall)= 1313
W4(ftg)= 1283
Wtotal= 7558
Fsrchg(lbs)= 0
Fa(lbs)= 3745
Fp(lbs)= 2756
Ffrict(lbs)= 3779
FS sliding= 1.74 FS slide reqd= 1.50
Net Sliding= -2790
Allowalbe Bearing Pressure
LF oveturn= 1.5
Ms-ot(R-lb)= 14569
Mu-ot(ft-lb)= 21853
D key(ft)= 2.00
3000 psf
Xcw(ft)= 2.45 Ecc-s(ft)= 1.93 Xresult-s(ft)= 4.38 Tr-s(ft)= 2.95
Ecc-u(ft)= 2.89 Xresult-u(ft)= 5.34 Tr-u(ft)= 1.99
3rd point-- 2.44
CASE= Service RESULTANT WITHIN MIDDLE 3rd Tr (ft)-- 2.95
Lbrg(ft)= 7.33
Ql(pso= 1634 5 3000 psf
Q2(psf)= 429
CASE= Ultimate RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 1.99
Lbrg(ft)= 5.96
Ql(psf)= 2535 :5 1.5 x 3000 = 4500 psf
Q2(psf)= 0
HEEL REINFORCING DESIGN
Top bar cover (in)= 2
Top bar size =
6
Top bar spacing (in)=
16
Depth to Reinf d (in)=
11.63
Comp Block a (in)=
0.56
d - a/2 (in)=
11.35
As provided (sq in)=
0.33
TOE REINFORCING DESIGN
Bot bar cover (in)= 3
Load Factor 1.5
Wall Mu= 15917 ft-lbs
Heel Mu based on Wdl 10753
Heel Mu DESIGN=
As reqd =
As min =
1.33 x As reqd =
I 1000 ft-lbs @wall
0.22 sq in per ft
0.47 sq in per ft
0.29 sq in per ft
Bot bar size =
6
Wall Mu - Heel Mu
5165
Bot bar spacing (in)=
16
Toe Mu DESIGN =
5200 ft-lbs @ wall
Depth to Reinf d (in)=
10.63
Comp Block a (in)=
0.56
As reqd =
0.11 sq in per ft
d - a/2 (in)=
10.35
As min =
0.43 sq in per ft
As provided (sq in)=
0.33
1.33 x As reqd =
0. 15 sq in per ft
I
SITE STRUCTURES
Project
Sharma
sheet C
10511 19th Ave SE, Suite C
date
Everett, WA, (425)-357-9600
prJ. no. S-19-083
10.5FT RETAINING WALL REINFORCING Active Pressure + Seismic
Ha(ft)= 11.67
EFWa(pcf)= 55
Tw(in)= 10
Tftg(in)= 14.00
Hp(FT)= 1.50
EFWp(pcf)= 300
Hw(ft)= 10.5
Wftg(ft)-- 7.33
FSpassive= 1.50
D(wall)pcf-- 150
Lheel(ft)= 3.50
CoeFrict-- 0.50
Dsoil(pcf)= 135.00
Ltoe(ft)= 3.00
Wseismic(psf)= 84.00
D(ftg)pcf-� 150
W I (heel)= 4963
F seismic= 980
Allowalbe Bearing Pressure
3000 psf
W2(wall)= 1313
Fa(lbs)= 3745
LF oveturn= 1.42
Fp(lbs)= 2756
Ms-ot(ft-lb)= 18911
W4(ftg)= 1283
Ffrict(lbs)= 3779
Mu-ot(ft-lb)= 26810
Wtotal= 7558
FS sliding= 1.38
FS slide reqd= 1.42
D key(ft)= 2.00
Net Sl iding= - 18 10
Xcw(ft)= 2.45
Ecc-s(ft)= 2.50
Xresult-s(ft)= 4.95
Tr-s(ft)= 2.38
Ecc-u(ft)= 3.55
Xresult-u(ft)= 6.00
Tr-u(ft)= 1.33
3rd point-- 2.44
CASE= Service
RESULTANT OUTSIDE MIDDLE 3rd
Tr (ft)= 2.3 8
Lbrg(ft)=
7.13
Ql(psf)=
2120 �S 3000 psf
Q2(psf)=
0
CASE= Ultimate
RESULTANT OUTSIDE MIDDLE 3rd
Tr (ft)= 1.33
Lbrg(ft)=
3.99
Ql(psf)=
3784 :5 1.5 x 3000
4500 psf
Q2(psf)=
0
REEL REINFORCING DESIGN
Top bar cover (in)�- 2
Top bar size =
6
Top bar spacing (in)=
16
Depth to Reinf d (in)=
11.63
Comp Block a (in)=
0.56
d - a/2 (in)=
11.35
As provided (sq in)=
0.33
TOE REINFORCING DESIGN
Bot bar cover (in)= 3
Bot bar size = 6
Bot bar spacing (in)= 16
Depth to Reinf d (in)--
10.63
Comp Block a (in)=
0.56
d - a/2 (in)=
10.35
As provided (sq in)=
0.33
Load Factor= 1.5
Wall base Mu= 22863
Heel Mu based on Wdl 10753
Heel Mu DESIGN= 10800 ft-lbs @ wall
As reqd = 0.21 sq in per ft
As min = 0.47 sq in per ft
1.33 x As reqd = 0.28 sq in per ft
Wall Mu - Heel Mu 12110
Toe Mu DESIGN = 12200 ft-lbs @ wall
As reqd = 0.26 sq in per ft
As min = 0.43 sq in per ft
1.33 x As reqd = 0.35 sq in per ft
SITE STRUCTURES Project Sharma sheet 11
10511 19th Ave SE, Suite C date IOL- 11 - 1 -1
Everett, WA, (425)-357-9600 prJ. no. S-19-083
10.5FT RETAINING WALL REINFORCING Active Pressure + Surcharge
• from top
Ms
Mu
As
Wall thick
8 in
1
6
9
0.000
Concrete cover
2 in
2
47
75
0.003
Rebar size
6
3
158
252
0,011
Concrete Strength f c
3500 psi
4
373
597
0.026
5
729
1167
0,051
Depth to rebar center
5.63
6
1260
2016
0.087
Comp block depth
1.11
7
2001
3201
0.139
8
2987
4779
0.207
9
4253
6804
0.295
10
5833
9333
0.405
11
7764
12423
0.539
12
10080
16128
0.699
13
12816
20505
0.889
EFWa(pcO
35
14
16007
25611
1.110
Surcharge(psf)
0
15
19688
31500
1.366
Soil Density(pcf)
125
• from top
MS
Mu
As
LF active
1.6
10.5
6753
10805
0.474
LF surcharge
1.6
8
2987
4779
0.210
Vertical ReinforcinLy:
bar size: 96
spacing: 16 " o/c
As =
0.33 sq in a
0.21
Footing to Wall Dowels:
bar size: # 6
spacing: 8 " o/c
As =
0.66 sq in ?:
0.47
tension controlled cracking: p:5 pt:
p =
0.0069 pt=
0.0158
development length: 30.4
Extend Dowels: 4.3 ft minimum into wall ---+ go to
5 ft
end hook development: 10.6
Embed Dowels: 7.6 in min into footing —
go to
I I in into
14 in ftg
Horizontal Reinforcine:
bar size: # 5
spacing: 12 " o/c
each face: no P
0.0032
2! 0.0020
SITE STRUCTURES Pro ect Shanna sheet
10511 19th Ave SE, Suite C date
Everett, WA, (425)-357-9600 prj. no. S-19-083
10.5FT RETAINING WALL REINFORCING Active Pressure + Seismic
Seismic Pressure Component
Uniform Lateral Earth Pressure 8 H psf 84 psf
Load Factor for Seismic Pressure Component 1.00
H from top
MIS
Mu
As
Wall thick
8 in
1
48
51
0.002
Concrete cover
2 in
2
215
243
0.011
Rebar size
6
3
536
630
0.027
Concrete Strength f c
3500 psi
4
1045
1269
0.055
5
1779
2217
0.096
Depth to rebar center
5.63
6
2772
3528
0.153
Comp block depth
1.11
7
4059
5259
0.228
8
5675
7467
0.324
9
7655
10206
0.443
10
10033
13533
0.587
11
12846
17505
0.759
12
16128
22176
0,962
13
19914
27603
1.197
14
24239
33843
1.467
15
29138
40950
1.776
EFWa(pcf)
35
Soil Density(pcf)
125
H from top
NIS
Mu
As
10.5
11383
15435
0.677
LF active
1.6
8
5675
7467
0.327
Vertical Reinforcing:
bar size: 6
spacing: 16 " o/c
As
0.33 sq in
0.33
Footing to Wall Dowels:
bar size: # 6
spacing: 8 " o/c As = 0.66 sq in 0.68
tension controlled cracking: p:5 pt: p = 0.0069 pt= 0.0158
development length: 30.4
Extend Dowels: 5.1 ft minimum into wall --+ go to 5 ft
end hook development: 10.6 "
Embed Dowels: 10.9 in min into footing — go to I I in into 14 in ftg
SITE STRUCTURES
10511 19th Ave SE, Suite C
Everett, WA, (425)-357-9600
Project Sharma
sheet
date
prJ. no. S-19-083
10.5FT RETAINING WALL REINFORCING Active Pressure + Surcharge
Ha(ft)= 11.67 EFWa(pcf)= 35
Tw(in)= 8 Tftg(in)= 14.00
Hp(FT)= 1.50 EFWp(pcf)= 300
Hw(ft)= 10.5 Wftg(ft)= 6.00
FSpassive= 1.50
D(wall)pcf-- 150 Lheel(ft)= 3.33
CoeFrict-- 0.50 Dsoil(pcf)= 125.00
Ltoe(ft)= 2.00
Surchg(pso= 0.00
D(ftg)pcf-- 150
W(surchg)= 0
WI(heel)= 4372
W2(wall)= 1050
W4(ftg)= 1050
Wtotal= 6472
Fsrchg(lbs)= 0
Fa(lbs)= 2383
Fp(lbs)= 2756
Ffrict(lbs)= 3236
FS sliding= 2.51 FS slide reqd= 1.50
Net Sliding= -3609
Allowalbe Bearing Pressure
LF oveturn= 1.5
Ms-ot(ft-lb)= 9271
Mu-ot(ft-lb)= 13907
D key(ft)= 2.00
3000 psf
Xcw(ft)= 2.21 Ecc-s(ft)= 1.43 Xresult-s(ft)= 3.64 Tr-s(ft)= 2.36
Ecc-u(ft)= 2.15 Xresult-u(ft)= 4.35 Tr-u(ft)= 1.65
3rd point-- 2.00
CASE= Service RESULTANT WITHIN MIDDLE 3rd Tr (ft)= 2.36
Lbrg(ft)= 6.00
Q I (psf)= 1767 S 3000 psf
Q2(pso= 390
CASE= Ultimate
RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 1.65
Lbrg(ft)= 4.94
Q I (psf)= 2622
:5 1.5 x 3000 = 4500 psf
Q2(psf)= 0
HEEL REINFORCING DESIGN
Load Factor
1.5
Top bar cover (in)=
2
Wall Mu=
10129 ft-lbs
Top bar size =
6
Heel Mu based on Wdl
8737
Top bar spacing (in)=
16
Depth to Reinf d (in)--
11.63
Heel
Mu DESIGN=
9000 ft-lbs @ wall
Comp Block a (in)=
0.56
As reqd =
0. 18 sq in per ft
d - a/2 (in)=
11.35
As min =
0.47 sq in per ft
As provided (sq in)=
0.33
1.33 x As reqd =
0.24 sq in per ft
TOE REINFORCING DESIGN
Bot bar cover (in)=
3
Bot bar size =
6
Wall Mu - Heel Mu
1392
Bot bar spacing (in)--
16
Toe
Mu DESIGN =
1400 ft-lbs @ wall
Depth to Reinf d (in)=
10.63
Comp Block a (in)=
0.56
As reqd =
0.03 sq in per ft
d - a/2 (in)=
10.35
As min =
0.43 sq in per ft
As provided (sq in)=
0.33
1.33 x As reqd =
0.04 sq in per ft
SITE STRUCTURES Project Sharma
sheet
10511 19th Ave SE, Suite C
date
Everett, WA, (425)-357-9600
prJ. no. S-19-083
10.5FT RETAINING WALL REINFORCING Active Pressure
+ Seismic
Ha(ft)= 11.67 EFWa(pco= 35 Tw(in)= 8
Tftg(in)�- 14.00
Hp(FT)= 1.50 EFWp(pco= 300 Hw(ft)= 10.5
Wftg(ft)= 6.00
FSpassive= 1.50 D(wall)pcf-- 150
Lheel(ft)= 3.33
CoeFrict-- 0.50 Dsoil(pcf)= 125.00
Ltoe(ft)= 2.00
Wseismic(psf)= 84.00
D(ftg)pcf-- 150
WI(heel)= 4372
W2(wall)= 1050
W4(ftg)-- 1050
Wtotal= 6472
F seismic= 980
Fa(lbs)= 2383
Fp(lbs)-- 2756
Ffrict(lbs)= 3236
FS sliding= 1.78 FS slide reqd= 1.36
Net Sliding= -2629
Allowalbe Bearing Pressure 3000 psf
LF ovetum= 1.36
Ms-ot(ft-lb)= 13613
Mu-ot(ft-lb)= 18458
D key(ft)= 2.00
Xcw(ft)= 2.21 Ecc-s(ft)-- 2. 10 Xresult-s(ft)= 4.31 Tr-s(ft)= 1.69
Ecc-u(ft)= 2.85 Xresult-u(ft)-- 5.06 Tr-u(ft)= 0.94
3rd point-- 2.00
CASE= Service RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 1.69
Lbrg(ft)= 5.07
Ql(psf)= 2552 3000 psf
Q2(psf)= 0
CASE= Ultimate RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 0.94
Lbrg(ft)= 2.83
Ql(psf)= 4579 1.5 x 3000 = 4500 psf
Q2(psf)= 0
HEEL REINFORCING DESIGN
Top bar cover (in)= 2
Top bar size =
6
Top bar spacing (in)=
16
Depth to Reinf d (in)=
11.63
Comp, Block a (in)=
0.56
d - a/2 (in)=
11.35
As provided (sq in)=
0.33
TOE REINFORCING DESIGN
Bot bar cover (in)-- 3
Bot bar size = 6
Bot bar spacing (in)-- 16
Depth to Reinf d (in)-- 10.63
Cornp Block a (in)= 0.56
d - a/2 (in)= 10.35
As provided (sq in)= 0.33
Load Factor = 1.5
Wall base Mu= 17075
Heel Mu based on Wdl 8737
Heel Mu DESIGN= 9000 ft-lbs @ wall
As reqd = 0. 18 sq in per ft
As min = 0.47 sq in per ft
1.33 x As reqd = 0.24 sq in per ft
Wall Mu - Heel Mu 8338
Toe Mu DESIGN= 9000 ft-lbs @ wall
As reqd = 0. 19 sq in per ft
As min = 0.43 sq in per ft
1.33 x As reqd = 0.26 sq iti per ft
SITE STRUCTURES Project
10511 19th Ave SE, Suite C
Everett, WA, (425)-357-9600
Sharma
sheet 10
date' 11,1 , 11
prJ. no. S-19-083
&OFT RETAINING WALL REINFORCING Active Pressure + Surcharge
• from top
Ms
Mu
As
Wall thick
8 in
1
6
9
0.000
Concrete cover
2 in
2
47
75
0.003
Rebar size
5
3
158
252
0.011
Concrete Strength fc
3500 psi
4
373
597
0.026
5
729
1167
0.050
Depth to rebar center
5.69
6
1260
2016
0.086
Comp block depth
0.56
7
2001
3201
0.137
8
2987
4779
0.205
9
4253
6804
0.291
10
5833
9333
0.400
11
7764
12423
0.532
12
10080
16128
0.691
13
12816
20505
0.878
EFWa(pcO
35
14
16007
25611
1.097
Surcharge(pso
0
15
19688
31500
1.349
Soil Density(pco
125
• from top
NIS
Mu
As
LF active
1.6
8
2987
4779
0.196
LF surcharge
1.6
6
1260
2016
0.083
Vertical Reinforcing:
bar size: # 5
spacing: 16 " o/c As = 0.23 sq in 2: 0.08
Footina to Wall Dowels:
bar size: # 6
spacing: 16 " o/c As = 0.33 sq in 2: 0.20
tension controlled cracking: p :5 pt: p = 0.0035 pt= 0.0158
development length: 25.4
Extend Dowels: 3.3 ft minimum into wall --+ go to 4 ft
end hook development: 10.6
Embed Dowels: 6.3 in min into footing — go to 9 in into 12 in ftg
Horizontal Reinforcing:
bar size: # 5
spacing: 12 " o/c
each face: no P 0.0032 0.0020
SITE STRUCTURES
10511 19th Ave SE, Suite C
Everett, WA, (425)-357-9600
Project Sharma
sheet
date
prJ. no. S-19-083
&OFT RETAINING WALL REINFORCING Active Pressure + Seismic
Seismic Pressure Component
Uniform Lateral Earth Pressure 8 Hpsf= 64 psf
Load Factor for Seismic Pressure Component 1.00
H from top
NIS
MU
As
Wall thick
8 in
1
38
41
0.002
Concrete cover
2 in
2
175
203
0.009
Rebar size
5
3
446
540
0.023
Concrete Strength fc
3500 psi
4
885
1109
0.048
5
1529
1967
0.084
Depth to rebar center
5.69
6
2412
3168
0.136
Comp block depth
0.56
7
3569
4769
0.204
8
5035
6827
0.292
9
6845
9396
0,403
10
9033
12533
0.537
11
11636
16295
0.698
12
14688
20736
0.888
13
18224
25913
1.110
14
22279
31883
1.366
15
26888
38700
1.658
EFWa(pcf)
35
Soil Density(pef)
125
H from top
NIS
MU
As
8
5035
6827
0.280
LF active
1.6
6
2412
3168
0.130
Vertical Reinforcin2:
bar size: # 5
spacing: 16 " o/c As =
0.23 sq in a
0.13
Footine to Wall Dowels:
bar size: # 6
spacing: 16 " o/c As =
0.33 sq in 2:
0.28
tension controlled cracking: p:5 pt: p =
0.0035 pt=
0.0158
development length: 25.4
Extend Dowels: 3.8 ft minimum into wall --+ go to
4 ft
end hook development: 10.6
Embed Dowels: 9.0 in min into footing go to
9 in into
12 in ftg
SITE STRUCTURES
10511 19th Ave SE, Suite C
Everett, WA, (425)-357-9600
Project Sharma
sheet
date
prJ. no. S-19-083
8.OFT RETAINING WALL REINFORCING Active Pressure + Surcharge
Ha(ft)= 9.00
EFWa(pcf)=
35
Tw(in)= 8
Tftg(in)= 12.00
Hp(FT)= 1.50
EFWp(pco=
300
Hw(ft)= 8
Wftg(ft)= 5.00
FSpassive=
1.50
D(wall)pcf-- 150
Lheel(ft)= 2.83
CoeFrict-- 0.50
Dsoil(pcf)=
125.00
Ltoe(ft)= 1.50
Surchg(pso=
0.00
D(ftg)pcf-- 150
W(surchg)= 0
W I (heel)= 2830
Fsrchg(lbs)=
0
Allowalbe Bearing Pressure
3000 psf
W2(wall)= 800
Fa(lbs)=
1418
LF oveturn= 1.5
Fp(lbs)=
506
Ms-ot(ft-lb)= 4253
W4(ftg)= 750
Ffrict(lbs)=
2190
Mu-ot(ft-lb)= 6379
Wtotal= 4380
FS sliding= 1.90
FS slide reqd=
1.50
D key(ft)= 0.00
Net Sliding= -1279
Xcw(ft)= 1.92
Ecc-s(ft)=
0.97
Xresult-s(ft)= 2.89
Tr-s(ft)= 2.11
Ecc-u(ft)=
1.46
Xresult-u(ft)= 3.38
Tr-u(ft)= 1.62
3rd point-- 1.67
CASE= Service
RESULTANT WITHIN MIDDLE 3rd
Tr (ft)= 2.11
Lbrg(ft)=
5.00
Q I (psf)=
1287 3000 psf
Q2(psf)=
465
CASE= Ultimate
RESULTANT OUTSIDE MIDDLE 3rd
Tr (ft)= 1.62
Lbrg(ft)=
4.87
Ql(psf)=
1799 < 1.5 x 3000
4500 psf
Q2(psf)=
0
HEEL REINFORCING DESIGN
Top bar cover (in)= 2
Top bar size =
5
Top bar spacing (in)--
16
Depth to Reinf d (in)=
9.69
Comp, Block a (in)=
0.39
d - a/2 (in)=
9A9
As provided (sq in)=
0.23
TOE REINFORCING DESIGN
Bot bar cover (in)= 3
Load Factor 1.5
Wall Mu-- 4480 ft-lbs
Heel Mu based on Wdl
Heel Mu DESIGN=
As reqd =
As min =
1.33 x As reqd =
4948
5000 ft-lbs @ wall
0. 12 sq in per ft
0.39 sq in per ft
0. 16 sq in per ft
Bot bar size =
5
Wall Mu - Heel Mu
-468
Bot bar spacing (in)--
16
Toe Mu DESIGN =
500 ft-lbs @ wall
Depth to Reinf d (in)=
8.69
Comp, Block a (in)=
0.39
As reqd =
0. 0 1 sq in per ft
d - a/2 (in)=
8.49
As min =
0.35 sq in per ft
As provided (sq in)=
0.23
1.33 x As reqd =
0.02 sq in per ft
SITE STRUMIRES
Project
Sharma
sheet
10511 19th Ave SE, Suite C
date
Everett, WA, (425)-357-9600
prJ. no. S-"19-083
8.OFT RETAINING WALL REINFORCING Active Pressure + Seismic
Ha(ft)= 9.00
EFWa(pcf)= 35
Tw(in)= 8
Tftg(in)= 12.00
Hp(FT)= 1.50
EFWp(pcf)= 300
Hw(ft)= 8
W ' ftg(ft)= 5.00
FSpassive= 1.50
D(wall)pcff- 150
Lheel(ft)= 2.83
CoeFrict-- 0.50
Dsoil(pcf)= 125.00
Ltoe(ft)= 1.50
Wseismic(psf)= 64.00
D(ftg)pcff- 150
WI(beel)= 2830
F seismic= 576
Allowalbe Bearing Pressure
3000 psf
W2(wall)= 800
Fa(lbs)= 1418
LF oveturn= 1.36
Fp(lbs)= 506
Ms-ot(ft-lb)= 6591
W4(ftg)= 750
Ffrict(lbs)= 2190
Mu-ot(ft-lb)= 8937
Wtotal= 4380
FS sliding= 1.35
FS slide reqd= 1.36
D key(ft)= 0.00
Net Sliding= -703
Xcw(ft)= 1.92
Ecc-s(ft)= 1.50
Xresult-s(ft)= 3.42
Tr-s(ft)= 1.58
Ecc-u(ft)= 2.04
Xresult-u(ft)= 3.96
Tr-u(ft)= 1.04
3rd point-- 1.67
CASE= Service RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 1.58
Lbrg(ft)= 4.73
Ql(psf)= 1854 :5 3000 psf
Q2(psD= 0
CASE= Ultimate RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 1.04
Lbrg(ft)= 3.12
Ql(psf)= 2809 :S 1.5 x 3000 = 4500 psf
Q2(psf)= 0
HEEL REINFORCING DESIGN
Top bar cover (in)= 2
Top bar size =
5
Top bar spacing (in)=
16
Depth to Reinf d (in)--
9.69
Comp Block a (in)--
0.39
d - a/2 (in)=
9.49
As provided (sq in)=
0.23
TOE REINFORCING DESIGN
Bot bar cover (in)= 3
Load Factor= 1.5
Wall base Mu--
Heel Mu based on Wdl
Heel Mu DESIGN=
As reqd =
As min =
1.33 x As reqd =
7552
4948
5000 ft-lbs @ wall
0. 12 sq in per ft
0.39 sq in per ft
0. 16 sq in per ft
Bot bar size =
5
Wall Mu - Heel Mu
2604
Bot bar spacing (in)=
16
Toe Mu DESIGN =
3000 ft-lbs @ wall
Depth to Reinf d (in)--
8.69
Comp Block a (in)=
0.39
As reqd =
0.08 sq in per ft
d - a/2 (in)=
8.49
As min =
0.35 sq in per ft
As provided (sq in)=
0.23
1.33 x As reqd =
0. 10 sq in per ft
SITE STRUCTURES Proj ect Sharma
10511 19th Ave SE, Suite C
Everett, WA, (425)-357-9600
5.5FT RETAINING WALL REINFORCING
sheet
date
prj. no. S-19-083
Active Pressure + Surcharge
H from top
NIS
Mu
As
Wall thick
8 in
1
6
9
0.000
Concrete cover
2 in
2
47
75
0.003
Rebar size
5
3
158
252
0.011
Concrete Strength fc
3500 psi
4
373
597
0.026
5
729
1167
0.050
Depth to rebar center
5.69
6
1260
2016
0.086
Comp, block depth
0.56
7
2001
3201
0.137
8
2987
4779
0.205
9
4253
6804
0.291
10
5833
9333
0.400
11
7764
12423
0.532
12
10080
16128
0.691
13
12816
20505
0.878
EFWa(pcO
35
14
16007
25611
1.097
Surcharge(psO
0
15
19688
31500
1.349
Soil Density(pcf)
125
H from top
Ms
Mu
As
LF active
1.6
5.5
971
1553
0.064
LF surcharge
1.6
5.5
971
1553
0.064
Vertical Reinforcine:
bar size: # 5
spacing: 16 " o/c
As =
0.23 sq in a
0.06
Footine to Wall Dowels:
bar size: # 6
spacing: 16 " o/c
As =
0.33 sq in 2:
0.06
tension controlled cracking: p :5 pt:
p = 0.0035
pt=
0.0158
development length: 25.4
Extend Dowels: 0.4 ft minimum into wall — go to
2.33 ft
end hook development: 10.6
Embed Dowels: 2.1 in min into footing —
go to
9 in into
12 in ftg
Horizontal Reinforcine:
bar size: 5
spacing: 12 " o/c
each face: no P
0.0032
0.0020
SITE STRUCTURES
10511 19th Ave SE, Suite C
Everett, WA, (425)-357-9600
Project Shanna
sheet 195
date - I-) - 6-
prJ. no. S-19-083
5.5FT RETAINING WALL REINFORCING Active Pressure + Seismic
Seismic Pressure Component
Uniform Lateral Earth Pressure 8 H psf 44 psf
Load Factor for Seismic Pressure Component 1,00
H from top
NIS
MU
As
Wall thick
8 in
1
28
31
0.001
Concrete cover
2 in
2
135
163
0.007
Rebar size
5
3
356
450
0.019
Concrete Strength fc
3500 psi
4
725
949
0,641
5
1279
1717
0.074
Depth to rebar center
5.69
6
2052
2808
0.120
Comp block depth
0.56
7
3079
4279
0.183
8
4395
6187
0.265
9
6035
8586
0.368
10
8033
11533
0.494
11
10426
15085
0.646
12
13248
19296
0.827
13
16534
24223
1.038
14
20319
29923
1.282
15
24638
36450
1.561
EFWa(pcf)
35
Soil Density(pcf)
125
H from top
NIS
MU
As
5.5
1636
2218
0.091
LF active
1.6
5.5
1636
2218
0.091
Vertical Reinforcine:
bar size: # 5
spacing: 16 " o/c As = 0.23 sq in 0.09
FootinE to Wall Dowels:
bar size: # 6
spacing: 16 " o/c As = 0.33 sq in 0.09
tension controlled cracking: p :5 pt: p = 0.0035 pt= 0.0158
development length: 25.4
Extend Dowels: 0.6 ft minimum into wall --+ go to 2.33 ft
end hook development: 10.6 "
Embed Dowels: 2.9 in min into footing — go to 9 in into 12 in ftg
SITE STRUCTURES
Proj ect
Sharma
sheet
10511 19th Ave SE, Suite
C
date
Everett, WA, (425)-357-9600
prj. no. S-19-083
5.5FT RETAINING WALL REINFORCING Active Pressure + Surcharge
Ha(ft)= 6.50
EFWa(pcf)= 35
Tw(in)= 8
Tftg(in)= 12.00
Hp(FT)= 1.50
EFWp(pcf)= 300
Hw(ft)= 5.5
Wftg(ft)= 3.33
FSpassive= 1.50
D(wall)pcf-- 150
Lheel(ft)= 1.67
CoeFrict-- 0.50
Dsoil(pcf)= 125.00
Ltoe(ft)= 0.99
Surchg(psf)= 0.00
D(ftg)pcf-- 150
W(surchg)= 0
WI(heel)= 1148
Fsrchg(lbs)= 0
Allowalbe Bearing Pressure
3000 psf
W2(wall)= 550
Fa(lbs)= 739
LF oveturn= 1.5
Fp(lbs)= 506
Ms-ot(ft-lb)= 1602
W4(ftg)= 500
Ffrict(lbs)= 1099
Mu-ot(ft-lb)= 2403
Wtotal= 2198
FS sliding7= 2.17
FS slide reqd= 1.50
D key(ft)= 0.00
Net Sfiding= -866
Xcw(ft)= 1.32
Ecc-s(ft)= 0.73
Xresult-s(ft)= 2.05
Tr-s(ft)= 1.28
Ecc-u(ft)= 1.09
Xresult-u(ft)= 2.41
Tr-u(ft)= 0.92
3rdpoint-- 1.11
CASE= Service RESULTANT WITHIN MIDDLE 3rd Tr (ft)= 1.28
Lbrg(ft)= 3.33
Ql(psf)= 1112 :5 3000 psf
Q2(psf)= 208
CASE= Ultimate RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 0.92
Lbrg(ft)= 2.76
Ql(psf)= 1592 :5 1.5 x 3000 = 4500 psf
Q2(psf)= 0
HEEL REINFORCING DESIGN
Top bar cover (in)= 2
Top bar size =
5
Top bar spacing (in)=
16
Depth to Reinf d (in)=
9.69
Comp, Block a (in)=
0.39
d - a/2 (in)=
9.49
As provided (sq in)=
0.23
TOE REINFORCING DESIGN
Bot bar cover (in)-- 3
Load Factor 1.5
Wall Mu= 1456 ft-lbs
Heel. Mu based on Wdl
Heel Mu DESIGN=
As reqd =
As min =
1.33 x As reqd =
1341
1400 ft-lbs @ wall
0.03 sq in per ft
0.39 sq in per ft
0.04 sq in per ft
Bot bar size =
5
Wall Mu - Heel Mu
114
Bot bar spacing (in)=
16
Toe Mu DESIGN =
200 ft-lbs @ wall
Depth to Reinf d (in)=
8.69
Comp Block a (in)=
0.39
As reqd =
0.0 1 sq in per ft
d - a/2 (in)=
8.49
As min =
0.35 sq in per ft
As provided (sq in)=
0.23
1.33 x As reqd =
0.01 sq in per ft
SITE STRUCTURES
10511 19th Ave SE, Suite C
Everett, WA, (425)-357-9600
Project Shanna
sheet / -7
date 12, -1 -)-In-
prJ. no. S-19-083
5.5FT RETAINING WALL REINFORCING Active Pressure + Seismic
Ha(ft)= 6.50 EFWa(pcf)= 35 Tw(in)-- 8 Tftg(in)= 12.00
Hp(FT)= 1.50 EFWp(pcf)= 300 Hw(ft)= 5.5 Wftg(ft)= 3.33
FSpassive-- 1.50 D(wall)pcf-� 150 Lheel(ft)= 1.67
CoeFrict-- 0.50 Dsoil(pcf)= 125.00 Ltoe(ft)= 0.99
Wseismic(psf)= 44.00 D(ftg)pcf-- 150
WI(heel)= 1148 F seismic= 286 Allowalbe Bearing Pressure 3000 psf
W2(wall)= 550 Fa(lbs)= 739 LF oveturn= 1.36
Fp(lbs)= 506 Ms-ot(ft-lb)= 2278
W4(ftg)= 500 Ffrict(lbs)-- 1099 Mu-ot(ft-lb)= 3089
Wtotal= 2198
FS sliding= 1.57 FS slide reqd= 1.36 D key(ft)= 0.00
Net Sliding= -580
Xcw(ft)-- 1.32 Ecc-s(ft)= 1.04 Xresult-s(ft)= 2.35 Tr-s(ft)= 0.98
Ecc-u(ft)= 1.41 Xresult-u(ft)= 2.72 Tr-u(ft)= 0.61
3rdpoint-- 1.11
CASE= Service RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 0.98
Lbrg(ft)= 2.93
Ql(psf)= 1499 :5 3000 psf
Q2(psf)= 0
CASE= Ultimate RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 0.61
Lbrg(ft)---�� 1.82
Q I (psf)= 2409 1.5 x 3000 = 4500 psf
Q2(psf)= 0
HEEL REINFORCING DESIGN
Top bar cover (in)= 2
Top bar size =
5
Top bar spacing (in)=
16
Depth to Reinf d (in)=
9.69
Comp Block a (in)=
0.39
d - a/2 (in)=
9.49
As provided (sq in)=
0.23
TOE REINFORCING DESIGN
Bot bar cover (in)-- 3
Load Factor= 1.5
Wall base Mu= 2454
Heel Mu based on Wdl 1341
Heel Mu DESIGN=
As reqd =
As min =
1.33 x As reqd =
1400 ft-lbs @ wall
0.03 sq in per ft
0.39 sq in per ft
0.04 sq in per ft
Bot bar size =
5
Wall Mu - Heel Mu
1113
Bot bar spacing (in)=
16
Toe Mu DESIGN =
1200 ft-lbs @ wall
Depth to Reinf d (in)=
8.69
Comp Block a (in)--
0.39
As reqd =
0.03 sq in per ft
d - a/2 (in)=
8.49
As min =
0.35 sq in per ft
As provided (sq in)=
0.23
1.33 x As reqd =
0.04 sq in per ft
SITE STRUCTURES Project Sharma sheet e2
10511 19th Ave SE, Suite C date Z-1-1-
Everett, WA, (425)-357-9600 pj. no. S-19-083
3.OFT RETAINING WALL REINFORCING Active Pressure + Surcharge
Ha(ft)= 4.00 EFWa(pcf)= 35 Tw(in)-- 8 Tftg(in)= 12.00
Hp(FT)= 1.50 *EFWp(pco= 300 Hw(ft)= 3 Wftg(ft)= 2.00
FSpassive= 1.50 D(wall)pcf-- 150 Lheel(ft)= 1.00
CoeFrict-- 0.50 Dsoil(pcf)= 125.00 Ltoe(ft)= 0.33
Surchg(psf)= 0.00 D(ftg)pcf-- 150
W(surchg)= 0
WI(heel)= 375 Fsrchg(lbs)= 0 Allowalbe Bearing Pressure 3000 psf
W2(wall)= 300 Fa(lbs)= 280 LF oveturn= 1.5
Fp(lbs)= 506 Ms-ot(ft-lb)= 373
W4(ftg)-- 300 Ffrict(lbs)= 488 Mu-ot(ft-lb)= 560
Wtotal= 975
FS sliding= 3.55 FS slide reqd= 1.50 D key(ft)= 0.00
Net Sliding= -714
Xcw(ft)= 0.91 Ecc-s(ft)= 0.38 Xresult-s(ft)= 1.29 Tr-s(ft)= 0.71
Ecc-u(ft)= 0.57 Xresult-u(ft)= 1.48 Tr-u(ft)= 0.52
3rd point-- 0.67
CASE= Service RESULTANT WITHIN MIDDLE 3rd Tr (ft)= 0.71
Lbrg(ft)= 2.00
Ql(psf)= 916 :5 3000 psf
Q2(psf)= 59
CASE= Ultimate RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 0.52
Lbrg(ft)= 1.55
Ql(psf)= 1261 1.5 x 3000 = 4500 psf
Q2(psf)= 0
HEEL REINFORCING DESIGN
Top bar cover (in)-- 2
Top bar size =
4
Top bar spacing (in)--
16
Depth to Reinf d (in)=
9.75
Comp Block a (in)=
0.25
d - a/2 (in)=
9.63
As provided (sq in)=
0.15
TOE REINFORCING DESIGN
Bot bar cover (in)-- 3
Load Factor 1.5
Wall Mu-- 236 ft-lbs
Heel Mu based on Wdl
Heel Mu DESIGN=
As reqd =
As min =
1.33 x As reqd =
313
320 ft-lbs @ wall
0.0 1 sq in per ft
0.39 sq in per ft
0.0 1 sq in per ft
Bot bar size =
4
Wall Mu - Heel Mu
-76
Bot bar spacing (in)--
16
Toe Mu DESIGN =
100 ft-lbs @ wall
Depth to Reinf d (in)--
8.75
Comp Block a (in)--
0.25
As reqd =
0.00 sq in per ft
d - a/2 (in)=
8.63
As min =
0.3 5 sq in per ft
As provided (sq in)=
'0.15
1.33 x As Teqd =
0.00 sq in per ft
I , t
SITE STRUCTURES
10511 19th Ave SE, Suite C
Everett, WA, (425)-357-9600
Project Sharma
sheet I q
date IS - 171 -1
prJ. no. S-19-083
3.OFT RETAINING WALL REINFORCING Active Pressure + Seismic
Ha(ft)= 4.00
EFWa(pcf)= 35,
Tw(in)= 8
Tftg(in)= 12.00
Hp(FT)= 1.50
EFWp(pco= 300
Hw(ft)= 3
Wftg(ft)= 2.00
FSpassive= 1.50
D(wall)pcf-- 150
Lheel(ft)= 1.00
CoeFrict-- 0.50
Dsoil(pcf)= 125.00
Ltoe(ft)= 0.33
Wseismic(psf)= 24.00
D(ftg)pcf-- 150
WI(heel)= 375
F seismic= 96
Allowalbe Bearing Pressure
3000 psf
W2(wall)= 300
Fa(lbs)= 280
LF oveturn= 1.36
Fp(lbs)= 506
Ms-ot(ft-lb)= 312
W4(ftg)= 300
Ffrict(lbs)= 488
Mu-ot(ft-lb)= 423
Wtotal= 975
FS sliding= 2.64
FS slide reqd= 1.36
D key(ft)= 0.00
Net Sliding= -618
Xcw(ft)= 0.91
Ecc-s(ft)= 0.32
Xresult-s(ft)= 1.23
Tr-s(ft)= 0.77
Ecc-u(ft)= 0.43
Xresult-u(ft)= 1.34
Tr-u(ft)= 0.66
3rd point-- 0.67
CASE= Service RESULTANT WITHIN MIDDLE 3rd Tr (ft)= 0.77
Lbrg(ft)= 2.00
Ql(psf)= 825 :S 3000 psf
Q2(psf)= 150
CASE= Ultimate RESULTANT OUTSIDE MIDDLE 3rd Tr (ft)= 0.66
Lbrg(ft)= 1.97
Ql(psf)= 992 :5 1.5 x 3000 = 4500 psf
Q2(psf)= 0
HEEL REINFORCING DESIGN
Top bar cover (in)= 2
Top bar size =
4
Top bar spacing (in)=
16
Depth to Reinf d (in)=
9.75
Comp Block a (in)=
0.25
d - a/2 (in)=
9.63
As provided (sq in)=
0.15
TOE REINFORCING DESIGN
Bot bar cover (in)= 3
Load Factor= 1.5
Wall base Mu= 398
Heel Mu based on Wdl 313
Heel Mu DESIGN=
As reqd =
As min =
1.33 x As reqd =
320 ft-lbs @ wall
0.0 1 sq in per ft
0.39 sq in per ft
0.0 1 sq in per ft
Bot bar size =
4
Wall Mu - Heel Mu
86
Bot bar spacing (in)--
16
Toe Mu DESIGN =
100 ft-lbs @ wall
Depth to Reinf d (in)--
8.75
Comp Block a (in)=
0.25
As Teqd =
0.00 sq in per ft
d - a/2 (in)=
8.63
As min =
0.35 sq in per ft
As provided (sq in)=
0.15
1.33 x As reqd =
0.00 sq in per ft
VER TIM DATUM
MORM AMMM VERMAL a4 MY- 19W
HORIZZINTAL VATUM
w 8JI91
WASHINGTON STATE COORDMES-NOKH ZONE
.aPXHMRK
PROJECT SENCHMM
FOUND 4-X4- VON IN CASE W1 1-�14' ORASS MSK W1 PUNCH, DOM
O,J', AT THE INTSPSEMN OF MDS GUtCY 040 AND 156TH STREET SW
EYVATION � 10035 FEET.
BASIS OF BF-4RING
FHE MONUMEN70 CENTERDNE OF 156TH ST SIV. BEMYNG= N 8F427f W
215
E
A � .�
g As :-a
_5
39
!? 3:
g i�
10
Z
z
a
E
E
� 4 .
5 AD
co
w
w
to LLJ
U)
w
,Z�
w
C)
cl) 0
RECEIVED
SEP 2 5 2018
CRTY c(Dpy
BUILDING
Lu
,�o oamlwo/
29t-101, 6'-0" 131-0.1 45'-6Y."
E
4�4' 4'-6" 8'-6" 4'-6" 4'-0" T-10" T-2" 8'4V? 191-01, H V.g
B g
E
t 2! t3
9
—Z
A,
�A,
j
"T
J�x
9
z
SAFETY 6080 SAFETY
j, 4�qs GLASS GLASSEN 0
GLASS
INE CEL AR
N W
x
3 REQ REQ
RIO UNDEREN11RE SLAB
ity Md=2�,3GA&BlDepartmerit
'A
O't
61
6
2678
70 Fa
- — --------- ------------
E
J
,,:A 3 �11 THEATRE
4
STORAG:
AN t In
x 8, @ 0 t
C14
_s-
RE
RIOUNDERENTI SLAB
RIO UNDER ENTIRE SLAB
7
5 CPM S.A.
----------
ii2
---------- -------------
-----------------------
24?81,( 2678 1
A2 LO NGE AREA
ELF CL E
MIN 20' x 20' zz A residential fire sprinkler system is
3 C:AR, (�;ARAGE FAN required. A recommended flow -through
-- ------ ---- PIN, j�-) design will meet specifications and reduce
21' 29' THERES10ENCE 2478 -- — ------ U)
equipment and continuing maintenance
z
requirements. ECDC19.05.02OB2. Provide 0
F.D. GYM z
HANIC ----------- 2
A)-ELEV __ ----- .111
0- a minimum combination water service of a C/)
W U)
T W
6" x , M,7 0
(0, x ro 14' x 15' one (I") meter and one and one half
a. SOURC13 OF -------------
EOTNTION IS NOT ibI ER'
LESSTHAN (11/2") service line, or show that domestic
18 INCHES AT30VE =�6&0.qft 5 Lu <
------- - --- -----
THEFLOOT ---------------- ------- — — ---------- and fire protection needs can be met with
LASPER
IFC 8 7 305.3
a smaller service.
------------------------------- '-3
------ U ---- U - ---------- Ll 1 14� P6,� (1 el 1-011�- 2; 5 11
Ki, -, (1,-041�6' I'-O"Y-9"
-0, -------------- ---------------------
nn:rol. F.D. : .1; : ::: tu
----------------- 7 7 >
7
I ------------------ .7 77� '� -7
---------------------------------- --------- -------------------------------------------------------------------------- --------------------------------------------
------------------------------------------------ ------------- -----------------------------------------------------------------------------
A7
BASEMENT LAYOUT
SCALE, 114" - It-O"
FLOOR AREA 1680 SF
GARAGE AREA 868 SF
OPEN TO ABOVE 100 SF
CEILING HEIGHT: V-0 3/4"
LINTEL HEIGHT: T-1 1 " (UNLESS NOTED OTHERWISE)
HEATING SOURCE: RADIANT FLOOR HEATING
26'-2"
TABLE R403.6.1
MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIR FLOW RATE MINIMUM
MINIMUM EFFICACY
AIR FLOW RATE MAXIMUM
(CFM)
(CFMfWATT)
(CFM)
Range hoods
Any
2.8 cfni/watt
Any
In -line
Any
2.8 cfin/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
< 90
Bathroom, utility room
7��, JA
90
A—
2.8 cfm/watt
N
Any
-
1'-3"
65 Lu
Lu
<
F2 Z Z
F. 9 (0)
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
C 17Y copy
0
.4
'CODE COMPLIANCE
ROW
RESUB
APR 0 9 2019
MUrC'11V
DQ Ellr1L,1,1l11.GD FA101T.1NT
Ell. US
PAGE #:
P-1
E
-6 3:2.
2
94'-4Y?
4�4' 31'-10" 13'-0" 45'-6Y2"
E�
16-0" 4'-0"
101-01, 8'- 1 9'-2't T-2" 5'-2V2"
05 O�
X-3%" 2'-0" 51-101, Y-10" 2-4"
E�
F-8%4"'
42" GUARD RAIL NG
12'(K A RD 11,114( - ----- - . ..... A
�F.D
C%f
GOVID—DECK--
Z
3.'
R
RISER. 11'EICUl"I
Tm
1: 192r 4A�P:Rjklll G: 30 80 -14080 3080
FT. 1: Z V6
1: 1: ON 16 A 1: t
gm
19 -----
I 1 141" IR 131 1
OFT I I I I I I I I I I I I I I
1 3�60 3 0
6080 5 80 m
-------- GREAT ROOM
19' x 20' KITCHE
OPEN 20'x 25'
TO 0
0 c
ABOVE
DEN —00
11' x 13' S.A.
C.M. b
e
MASTER S.A. S.A.
]JI K,
15' x 16'
F.D.
e
S.A.
1411
0 L V 5078 50 so R 2880
A.
U)
C.M.
FAS PER IRC 303 7 & R301 81 z
0
9 RISER HEIGHT =7-3/4' MXI PF
TREADDEPTH=10-MIN
3080 tt, a co
cr BAW Kl--CHEN =� w
tt
C.M. 5' x 9'
a
4' K 9'
LU <
N
OV�D L E VAJ C' ----- TO
BATH 6'x 7' 1 ABOVE
c x
AN (E2'
Q5
S.A. EAN
6013 1
VTO Wl�
C.M. so C. 40130 40130
Ll
9 p T)
'. "OWD' I�LEVhT( To N
A V
rBOE
n
,IS ENCLOSED
SHOWER ----------------------- F.D. F.D.
w
w
z
w
LU CC
Z
3: 0
2'-2%", T-6" 0500
8'-2%" 4'-0" 10'-3" 6-10" 33'-0" 2'-0" 9'-OV2"
22'-51/? 45'- 11 4'-8%"' 5'-6" 4'-8%"
94�4%"
MAIN FLOOR LAYOUT
5CALEs 1/4" - 1'�" �D
0
FLOOR AREA 2484 SF >-�
DECK AREA 1119 SF
CEILING HEIGHT: 10'-0 3/4" RESU
LINTEL HEIGHT: T-1 1 " (UNLESS NOTED OTHERWISE) B
HEATING SOURCE: RADIANT FLOOR HEATING APR 0 9 2019
BUILDING DEpARTMrNT
crryoFEDMONDS
L
2 Z;
27'-5'/?
d
DECK EXPOSED FRAMING
5
TO BE PRESSURE TREATED WOOD
F.D.
0,219
IRC R317
94'4W'
4'-0" 3Y-10" IY-0"
45'-6Y2"
Li
C?
1 -6" Y-6" T-6" 11'4" 19'-61/2"
T
14Y-6"
ll'-6"
3'-0" 2'-6" 51- 5'-6" 6'-6" ff-6" -01,
101, 10, 9' 2"
.2'-3V4" 5-3V4" 5'-6" -6t/
-0" .6"
7' T
-5" '-1"
3' 8
9
14080
12080
5080
a==
S
0
60
59 3060 Wn 4020 zt $060
o?
MASTER
V3
BATH
I V 1
I
, x 2
EGRESS EGRESS
14'x 15'
L
OPEN
A
FAN
r
TO
0
BELOW\
cl
2480 kD"M # 1
26BU I N
11 3'
BEDROOM # 3 1 x 0' FAN
S.A.
VTO
50 cpm
AN SA,
F�
10050
S.A.
SITTING
36" GUARD RAILING
10'x 14'
5080
A I
'-o
S.A.
10 C.M.
o? 36" GUARD RAILING 36" GUARD RAILING
D
F.D x
9' x I l'
CLF N\N\
RY
RY OP
6'x 7 ELEVATI R TO
AN 5'x 6' . . .
Z BELOI
rDR
lol- V"
U)
A
S.A. <
< t7EG
z
#2
BEDROOM # 2 D
B E
I 1=7 I I I
0
13'x'14' FAN ELEdrRIC I j
1 39x�l 4, VTO
j
50 Cpm 20180 40180 18030
Ll Ll
w
AN
w <
ROOFOVERRANG
Ll
- - - - - - - - - - - - - -
12030
0
Z
74" 6-9Y? 4!-0" 14�-63 /4 9'-23/4"
co
<
14'-1 V2" T-6" Y-10' 6-10" 33'-5V2"
z
22'-5Y2" 46'4Y2"
14�-OYV
11'6'
w
Z
94'-41/2"
o
UPPER FLOOR LAYOUT
SCALE, 114" - 1'�"
FLOOR AREA 1770 SF
CEILING HEIGHT: 9'-0 3/4"
LINTEL HEIGHT: T-1 I" (UNLESS NOTED OTHERWISE)
HEATING SOURCE: RADIANT FLOOR HEATING
0
PT-1
RESUB
APR 0 9 2019
sUl- 11G DFP.ARTME
...NT
—ToAofParapcLW -��-2&7-50
_r9L
1._p_2f Upp., %e 6
_2�
lop_2.f PMer Subp— J �!� 277'
iop o2f Main -Plate- — Y-216'
lop_dMain.�ubqoor Lo:267
lop -of Ba selpent PLate - 266
j __MgGr��e 2�L75
_____L _ _
0
jop_gf�3�-qrnt Flo- 2 8
lop-QfGamp
FRONT ELEVATION
SCALE; 1/4" - V-0"
LEFT ELEVATION
SCALE, 1/4" . 1'-0"
RESUB
D BY PLANNING
APR 0 9 2019
BUILDINGDEPARTM NT
CfTY OF EDMONDS
'A 0
AE
2�
m
w
W
0
z
0
6i
w cl)
w
cc
5W
a
F-
65 uJ
w
oz�
0 0: F<
< w
W Z
80
05 0
PAGE #:
P-4
w
to
M
n
cr�� '.�g C--
zr
0
tTJ
I SCALE: 1/4'= V-0' DISCLAIMER:
ELEVATIONS -SITE ADDRESS: 15-7;2 12ND AVE W CITY: EDMONDS 778.889.0002 rhomedesigne.com DRAWNBY-. DAN SIDHU 0 2012 These plarer wntain copywrighted information Umf is the,ol, property
m OWNER NAME: AM T EMAIL deldlauftremclo,re of Green Glmar Home Desilms Ltd. Repmducb,n in part o, hol, without
ADDRESS: Surrey, BG the writte permiseion of Greari Clmrar Home Desigm Ltd is prohibited.
(-nt CONTACT #: 425-280-8451 11 �- DATE: Friday, March P2,2019 Owner is nto be embedy responsible for all structural engineering requirements.
2015 W
CLIMATE
CROSS SECTION A -A
SCALE; 1/4" - I'-d'
AND MARINE 4
FENESTRATION U-FAC R
0.30
SKYLIGBT U-FACTOR
0.50
CEILING R VALUE
R-49, SINGLE RAFTER
TO R38 AS PER WSEC
WOOD FRAME WALL
�VALUE
R21 PLUS R 4
FLOOR R-VALUE
R38
BELOW -GRADE WALL LUE
R-21 IN PLUS R 5
SLAB R-VALUE AND DEPT�
R- 10,2 FEET
HVAC: 6IT H��
TABLE 406.2 ENERGY
FT �nOR A -R F A R ROT TIR F 4 � CR FDTT
EXCEEDING 5000 11
DWELLING UNIT
FLOOR AREA
(square feet)
NUMBER OF BEDROOMS
0-1 12-314—S-)-o-71-7
Airflow in CFM
< 1,500
1,501-3,000
3,001 — 4,500
4,501 — 6,000
45
60 1
75
90
105
60
75
90
105
120
75
90
105
—
120
6,001 — 7,500
90
105
S�p
13T
� U11110
> 7,500
1175
=
—M
3aHIGH EFFICIENCY HVAC EQUIPMENT:BOI0ER WITH MIMIMUM EFUE OF 92%
4a.HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM: All heating and cooling system components
installed inside the conditioned space. This includes all equipment and distribution system. components such as
forced air ducts, hydrome piping, hydronic floor heating loop, convectors and radiators. All combustion
equipment shall be direct vent or sealed combustion. For forced air ducts: A maximum of 10 linear feet ofretum
ducts and 5 linear feet of supply ducts may be located outside the conditioned space. All nivallic, ducts located
outside the conditioned space must have both transverse and longitudinal joints sealed with mastic. If flex ducts
are used, they cannot contain splices. Flex duct connections must be made with nylon straps and installed using a
plastic strapping tensioning tool. Ducts located outside the conditioned space must be insulated to a minimum of
R-8. Locating system components in conditioned crawl spaces is not permitted under this option. Electric
resistance heat and ductless beat pumps are not
permitted under this option. Direct combustion beating equipment with AFUE less than 80% is not pennitted
under this option. To qualify to claim this credit, the building permit drawings shall specify the option being
selected and sliall specify the ]testing equipment type and shall show the location of the healing and cooling
equipment and all the ductwork
5c:EFFICIENT WATER HEATING: Water heating,system shall include one ofthe following: Gas, propane or oil water beater with ii�nitnurn EF
1.5
ofo.91
lb.EFFICIENT BUILDING ENVELOPE: Prescriptive compliance is based on Table R402.1.1
with the following modifications: Vertical fenestration U = 0.25 Wall R-21 plus R-4 ci, Floor
R-38 Basement wall R-21 int plus R-5 ci Slab on grade R�10 perimeter and under entire slab
Below grade slab R-10 perimeter and under entire slab
PRE -FINISHED ALUMINUM SOFFIT
EOUALLY SPACE0 VENT15
EXTERIOR AIR FILM APPLIEr> TO UPPER SURACE OF INSULATION
2"XIV 0 24" O.C.
INSUATLION IN CAVITIES AS PER UISEC
POLY VAPOR EARRIER
12.1mm 1/2 C.IPSUM 0OARD
E.
in
z
L)
A
1/2" SWEA ING
2X& STUDS 0 16'
INSULATION PER WSEC
6 MIL POLY VAPOR BARRIER
I� GYPSUM BOARD
lydronic Heating --
d
.mbedde Joints —joints ofpipc or tubing that are embedded in a portion of the building, such as
oncretc, shall be of steel pipe, copper tubing, polybutylene, or polyethylene and comply with IMC 1209.3.
4ot Embedded Joints — Joints of other piping in cavities or running exposed shall be joined by approved
iethods in accordance with manufacturer's installation instructions and related sections of the IMC, per
MC 1209.4.
'hermal Barrier Ra�quired — A thermal barrier is required, except in engineered systems where it can be
.emonstrated that the insulation will decrease the efficiency or have a negative effect on the installation,
er IMC 1209.5.
The R-10 insulation under the Basement will serve as the thermal barrier for
be Basement Floor, per IMC 1209.5.
The thermal barder for the hydronic, heating serving the Main and Upper
?Ioors shall consist ofmaterials having a minimum R-value of 11, per IMC
209.2.
Provide a thermal break between the heated slab slid the foundation wall or
ither conductive slab per IMC 1209.5.3.
Insulating thermal barriers shall be installed with the manufacturees R-value
Bark readily observable upon inspection.
RESUB
APR 0 9 2019
BUILDING DEPARTMENT
CITYOFED M ONDS
2
P
E
z
z
0
LU U)
U.]
a
In!
6
-1
U)m
U.I
cc
Ciz�-
am(.)
< LLJ <
Z Z
go
U) ()
Z
00
b �
PAGE #
P-6
POLY&MNYLENE (110. . ".�
SEALED TO WOUSBURAP (Al%J
PLOOR FINI ON —
CONCRETE TOPPING
BATT INWI-ATIO14—
POLYEWLENE (v.s.
STAPLED IN PLACE
POLYE�YLENB W.D. 4 A.S.�
SEALED TO wousamllp (A.M.)
mEcT SCRm_
I WE
IN 0-1
NMI:
FA
MROSS - CAVITY
FLASWING
� FIN? ON -
Ncam TOPPING
OEAL WOUSMURAP (AA
TO FRAMNO
�N � PAPS —
TO LAP 0
ADRERM Na
FLASHrNG —
------ Exmm C4.ACDrNG
614EATq ING MEMBRANE
1/2'PLYWOOD SHEATHING-
-R 4 INSULATION
R 21 INSULATION IN STUDS
2X6 STUDS 0 16 O.C.
MIL POLY VAPOUR BARRIER
1/2" GYPSUM 50'ARD
------ VCUGUURAP AT
HEADER (A.06)
AL FLASHNG ON
ml.RANR ON
—� P.T.
� BLOCKING
4 INKAGEGAP
10, S�VATI4114G
WMENID VAMPRoopm TO — MANAGE
EMS OP FOOTINIS AWID UNDER WALL SIM FELTW CLOTH MAP
. TYPICAL EXTERIOR WALL DETAIL
SIALAW BETWEEN
POLYMNYLENE AND
WOUSEWRAP (A.B.)
+1OUSWRAP AT
� (AID.)
R 30 BATT INSULATION
STAP� IN P�E
-� �� �NG M.D.)
SILL GASKET (As.)
I
CZ-,ENr OR ACRYLIC
WILICCO PARGrNG
1- — — —�--
C., -OCIFING
CONCRETE �AT N BJX-L (A-)
614FATHING PAPER
BOOD aluDo — P., S" PLATE
R-11 �TION
I'myst"YLID& N.5)
GYPbL" BOARD
tom aw) OAP
N. . AND A.B.)
300M (w) BLYOW
MOE FACE OF WALL
OEAL POLYEtWYLgRE fA M 4
To WOtIO�p -0.)
FLOC,R FIN] ON
RDONN. SWIN�
—*EA�LCA�WJOTN�TAT
W ATIERPROOF ROOF MEMVMWR2 (M.D.) FOR
EAVE PROTECTION
ROOF, SHEATHIM
IDOOD ROOF FRAM�
DAn INS�TION
POLYET14YLME (A B, 4 W1.)
GYPWM WA�
VW4t
TO WOUSSWRAP (A.D.)
GUA�
VENtW ALUMIRIM
SOFFIT PANEL&
R FLASWN.
DETAIL
TYPICAL OVERHAND & WALL CONNECTION
ING PAPER TO
EXTERIM CLADDING
12,DI (3/4") APR SPACE
LAP METAL Nd
WWI PAPER a ND
P,T� WOW WRAPPING
FLASHING AND INTO
SHEAT14 NO PAPER (M.9d
SPEAT14ING
WINDOIIJ 0.
tPDOID FRAMING
BATT INSULATION
POLYETWYLEM (45 AND V.mj
O"r— MCAR�
SEAL POLYENYLENE �.D.
SWEATHING PAPER (&B.)
SEAL �TWING PAPER
— — FRAME
SLOPED �ILL—
FRAMM
LAP POLYETWYLEN2 AND —
SEAL Avwm�
MEMM�� M. AND �.S.)
S��NG PAPER
P.T. avoti PLATE,
P�T, WO00 B�KING
M R S— (114') GAP
5= GLAD AND
F�ATION WALL FILLM
WITM ASPWALT4MPRM
FIB�ARO AND
�L�LWM AGAMT WALL
— I M.01)
PRISFINISME) METAL FLASHING
CAU rmna TO EKroo
2b- W) P.IOT END OF
WINDOW Wll�
WAL POLYEWLENE MIS 4
TO WOUSEWIRW U.S.)
An SPACS/
STRAPPING
p"'M
1= CLA.DING
61MAIII
FRA—
I I I AIR SPA�E/
P.T� � STRA�ING
SlWAT4 NO PEPNR M..)
FLANGE
SAW rNBULATIO
POL�� (A.15 AND
101.t�
ow"T41M
PRAMM
GYPWH —A�
BATT rNSMATION
P�YETHYLENE (" AND 0)
AT PERRIMM OF WOOD
GYP� WARD
25.4- (1")
-------------
S�IIATWING I-Apot
ISOD AND
6OLrN MFTALLI� Hi
�TWM PAPER
69ALANT RANGE
AM SEALANT
I— f3l-V) AN SPA�g
P.T. � 6TMAF�IN.
SWEATWINd PAPER MB.l
SIMAT41—
w ING PAPER TO LAP
OVER METAI- PLATE
— ------ S.W METAL PLATE AROU� PIPE
�—FILLET BEAD OF eRALAW AT PEMMETER
I I I I " I L�w
PIPE
—FILLFT BEAD OF SEAILAW AT FMIMSTW�
-LAP METAL PLEAT9 O� SWATHING PAPER
INTERIOR EXTERIOR
WK �FACES
-KING ON 'E"
r
PAVI!R8 PEDESTALS
BEAL � FR44E TO CONCRETE TOPPING ON DRAINAGE MAT
HEMBRANS (M.111d
M
6EAL FOLTET�LENE TO —AD� MEMBRANE FLAS14ING (M.D.)
1
(Maj TO LAP —M VWK MEMBRANE
NYL0 —P.T. SH
WAL POLYE I M TO 4 M
-8. 1 V.S.) FLATS —*SALAW FILLET JOINT
— ". 4
CO.— TOPP�
SEALANT OR GAINKS
ISAM� INS"TION—
POLYETHTLIENE (Y.8
STAPLED N PLACE
IBRALAW AW BACKER ROD
XIW AT Wil— FA� W
L�
MEMISRAW M., AND M.15.)
SEALANT FILLET XrNT
PREFINIWED "AL MIP FLASHING
69ALANT OR GASKET JOINT o
*almml�l, — (W)
POLTETRYLUM (A.& 4 VAW
P.T. SHIM BEHND WINDOW
TO PLATE MD.)
TO CREATE DRAINAGE PATH
(ALTER"rulLr MILL HOLES OR BLOT$
THROLIGN Vll� FLANCM TO
ALLOGI FOI`�
ADHERED M==LASRING
TO WrIM � (1r) AND
LAP OVER INWATWNG PAPER
TYPICAL TOP & BOTTOM.Mjt!��
VENTED ALUMINIJM SOFFIT PANELS
6 -W
nr
10- OW) AIR SPACE/
P.T. �D STRAF�M
SWEATH NO PAPER M.15.)
�MNG
�D FRAMING
ISATT NWLATION
POLYIEWLENS (A YJS,)
OYPS� WARD
DOOR SILL DETAIL -D
DOUBLE LAYOER BREATHERABLE BUILDING PAPER ON
1/2" FIR PLY SHEATHING ON
2" X6" WOOD STUDS@ 16" O.C.
R-20 BATT INSULATION ON
6 MIL U.V. POLY VAPOUR BARRIER ON 112"GWB
.. I I /pFo0LMymDAT=0N
AIR DAMPPROOFING
MEMBRANCE
MIN R-10 EXPANDED
POLYSTYRENE FOAM
i GRANULAR FILL
TYPICAL GARAGE WALL DETAILUNHEAT
AINTED METAL �IILING
e,—P
SOL N �ALLII F%EFlNI
P.T. INOOD S�KM
A
PROM-16HIED METAL
TYPICAL GUARD/HANDRAIL DETAIL
(A"S
SEAL POLYMLYME (A.S.
a
IOR CLADDING
To AMMISMAP Mild
rA 5
15tv (3/4) AIR SPACE/
FLOOR PINION 0
LILQ
�TI4 G PAPER (M.5)
CONCRETE TOPPING
6HPATWING
FRAMING
MATT NWILATION
POLYETWYLENE (A.B. 4 �5,)
GYP� BOARD
AT � (A.D.)
DETAILS 2 4 4
8 NSJLATION
Lt.—
POLYMYLE14E lV,9d
METAL FLASHING
�NSSCT SCREEN
(W4.) MIN,
AL,jMlNuM
____,:L A.B.)
GEALW TO NOUSSURAP (A.B.)
CANTILEVERED FLOOR DETAIL ABOVE PORCH
42- Mft 140"T FRO
EDGE OF ALCONY
1� PICKETS
1-
ATERPROOF
SLOPL�W C—*AN
2 WWW'
MIN, k,_
BELF AD�
�r.SPANE ON Top
tAPERS
-,AL FLASHING
+
SALDOW
MEM��
L__��W ll*t* ITRAPPING
FLAT ROOF / DECK OVER LIVING SPACE
�,`JB TREATED
AS REQJI�
L FLASHING
RESUB
APR 0 9 2019
BUILDING DEPARTMENT
CITYOFEDMONDS
@
-E
.He
E .9 75
6d
2
g
zg
Z
Lij
c6 52
U)
0
z
0
LLI
Lu <
W,
6
Lu
co
Lu
cc
z
< Lu
UJ Z
co 0
z
u
PAGE #:
P-7
SW 1/4, SECTION 5, TOWNSHIP 27 NORTH, RANGE 5 EAST, W.M.
M A R D E N C E
OWNER
TM-ITSHARMA
1737A NW 60TH ST
SEATTLE, WA 98107
TAX PARCEL NO.
0051300002411
LOT SIZE
72,606 SO FT
LOT COVERAGE CALCULATIONS
BUILDING FOOTPRINT: 2,667 SOFT
C VERED DECK: 1,158 SOFT
WALLS (135 LF > 3'HT x 8") 91 SOFT
TOTAL: 3,916 SOFT (17.3%)
HEIGHT CALCULATION
A: Z60.0.
B: 275.5'
C: 263.0'
+D: 2 .0'
1051.5'/4 = 262.90'AVG
+251 ALLOWED
= 287.90' MAX HEIGHT
Ac rUAL BUILDING HEIGHT = 287.50'
SURVEY INFORMATION (REF. MEADOWDALE ESTAT1,S PLAT)l
VERTICAL DATUM
NORTH AMERICAN VERTICAL DATUM-1988
HORIZONTAL DATUM
NAD 83/91
WASHINGTON STATE COORDINATES -NORTH ZONE
HORIZONTAL DATUM
PROJECT BENCHMARK:
FOUND 4"XV'MON IN CASE W/ 1-3/4" BRASS DISK
W/ PUNCH, DOWN 0.3, ATTHE INTERSECTION OF
LUNDS GULCH ROAD AND 1S8TH STREET SW
ELEVATION = 100.85 FEET.
BASIS OF BEARING
THE MONUMENTED CENTERLINE OF 156TH
ST SIN. BEARING = N 88*42'22" W
REFERENCES
SNOHOMISH COUNTY RECORD OF SURVEY
RECORDED UNDER AF NO. 9704075002.
SNOHOMISH COUNTY RECORD OF SURVEY
RECORDED UNDER AF NO. 200608035307.
FOUND NAIL W1 Y-
& WASqER SET IN
POTHOLE (MAY 201J)
BASIS OF 864RING
- — - — - — - N884222W 65,9.93,
C&CULAZED POS11701V OF MONUMENT
NOT 10SITEO THIS SURVEY
(U4Y 201J)
RETAIN TREE ALL TREES TO BE REMOVED
'40TED �X CB
E T..: ..
ON -SITE UNLEIS
6'
'�6 (I
OlpElf ISE i�-;'l )Pvq N S
iv
C�HAI NK/ ENC
4 GAP IN FENC PRO E, AE
'T
DUE TO TREE/ 244-.0 AN ST/OF NOR EAST SOR
OPERTY/COMR
5N CA1311 Ka 'PR
4!
'B� 8 �WIRE. KCE 158 "1 7
w
r p C)
AQOVEE 7�§ Z
GRAD
I / 1 1, L, . ESTOO
I I" I Nff� TRIS\ EX SSMH
77" RIM=279.74'
FbjK \ I 1\ \ � L M. F�T
IE=269.33' 8N
RE Al IN.Q IE=268.83' 8"S
_ABOW W I PER
'ZI PATIO
_i713 71
XIR—IM=
EX CB
7- v A,
Bpotivitq I wt-/.ba u v E=269.56'(12-O)l
N FF 6g�o
M�
U PIER Fft-2
As �E 6 :g: X CB
ENIRY �v
/RIM=273.07-
J x
EX CB
E=278.05'�4*0)P\
E=276.25' 24"0)1
A
CB
10 A41. 0.63,
R .11R4GE,
GARAG "4��1'1: 2:01�PVI Sl
MR �1'2 VC
5&
IGA
E=267.53'8"0)PVC NV
F Fi
i
Fi
N
N
N
N
N'
)F
91NT
FLOWUNE OF
M POLE THICKENED EDGE
p
j. 05�
'EE ST. :Q
0
43 IN
t� 0 'p
g EaX
....... 262.66'
�1:2 2:�I�PVI' N
E " ':�12
i#4'dl' 211:B(3
IE=256,46' 6"0)PVC NE
C13 EX CB
'216.,3
2
2)� E-264.22'(4',b)PVC E
iE=263.02'(24 o)PVC S
21 Dj Iz 10'
%
3,12 _SF, -240--\ EX SSMH
RIM=260.10-
Rc IE=250,03' 8"N
-238- 'k- E
IE=249." 8"S
X
--236- E B�
C
R M=255.99
SITE PLAN
SCALE: 1" = 20'
20 0 10 20 40
0051
N
ED BY PLANNING
Zone Comer FOUND J" SS DISK
_jA Fls w DOWN 0.6'
�a_etbacks Re-quired Actu Y2 lj
Front Z�':� - 0
Sides I
to
Rear -,I-/
Other
Hew
RESUB
ITY COPY
JAN 2 3 2019
FIARTIMENT
".ONDIS
GED CM11
(ENIGNiERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
01111119 1
z
0 co
Z
V 5
00 00 M
DESIGN: VD
DRAWN:
ATD
CHECK:
Jpu
JOB NO:
18044.20
DATE:
08/21/18
(0
Lj �:: 04
0 0
La 00
z > 0)
L,j
<
<
0 3: Z
LLJ Z <
Q� N (ji I
r-
< 0 n
:2 04 Z
x — 0 LLI
< r-, M �--
o
3: Lr) 0 —
I
I
V) — LLJ cn
ul
SHEET
'A
CO.1
SW 1/4, SECTION 5, TOWNSHIP 27 NORTH, RANGE 5 EAST, W.M.
DENCE
m r__'MA RE'�:)
S' - -'A'R �
15712 72ND AVE W
I CAUTION1
F_cA_LL BEFoRE You pidi
BURIED UTILITIES EXIST IN THE AREA AND UTILITY
INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT
THE ONE- CALL UTILITY LOCATE SERVICE A MINIMUM OF 48
HOURS PRIOR TO CONSTRUCTION
1-800-424-5555
EDMONDS,
WA 98026
HAULROUTE
TO SITE (APPROACHING FROM SOUTH): FROM 1-5, EXIT 181A FOR
44TH AVE W, LEFT ON 44TH AVE Wa(APPROACHING FROM
OWNER CONSULTANTS
UTILITY PURVEYORS
LEGAL DESCRIPTION
NORTH): FROM 1-5, EXIT 181 ONTO 196TH ST SW WESTBOUND,
AMIT SHARMA ARCHITECT
CIVIL ENGINEER
WATER/SEWER/STORIVI
NATURALGAS
FIRE
MEADOWDALE BEACH BLK 000 D-11 LOT
TURN RIGHT ONTO 44TH AVE W
R
1737A NW 60TH ST GREEN CLOVE HOME
DESIGNS CG ENGINEERING
CITY OF EDMONDS
PUGET SOUND ENERGY
FIRE DISTRICT ONE
1 CITY ED SP NO PLN2014-0015 REC AFN
201612095001 BEING A PIN LOTS 24 &
LEFT ON 168TH ST SW, RIGHT ON 66TH AVE W, CONTINUE WEST
ON MEADOWDALE RD, RIGHT ON 68TH AVE W, LEFT ON 160TH ST
SEATTLE, WA 18362 568 AVE
SURREY, BC V3S6G8
250 4TH AVE S, SUITE 200
E MONDSWA98020
D
121 5TH AVE N
EDMONDS, WA 98020
PO BOX 91269
BELLEVUE, WA
12425 MERIDIAN AVE
EVERETT, WA 98208
25 EXST PLAT
SW, CONTINUE NORTH ON 70TH AVE W, CONTINUE WEST ON
778.889.0002
425.778.8500 FAX 778.5536
425.551.1200
156TH ST SW, LEFT ON 72ND AVE W.
CONTACT: JARED UNDERBRINK
DATUM
FROM SITE: NORTH ON 72ND AVE W, RIGHT ON 156TH ST SW,
CONTI N BE SOUTH ON 70TH AVE W, CONTINUE EAST ON 16OTFI ST
NAVD88
SW, RIGHT ON 68TH AVE W, LEFT ON MEADOWDALE RD,
POWER
TELEPHONE
CONTINUE SOUTH ON 66TH AVE W, LEFT ON 168TH ST SW, RIGHT
SNOHOMISH COUNTY PUB
COMCAST
ON 44TH AVE W.
Po BOX 1107
15815 25TH AVE W
EVERETT, WA 98206
LYNNWOOD, WA 98087
CONTINUE SOUTH ON 44TH AVE W TO 1-5 SOUTH aR TURN LEFT
425.793.1000
ONTO 196TH STREET SW THEN TAKE EXITTO 1-5 NORTH.
NOTE: CITY MAY REVISE AS APPLICABLE BASED ON VEHICLE SIZE.
f--CKICDAI KInTPQ
GENERAL NOTES:
CONSTRUCTION SEQUENCE N I OTES:
1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF
19. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL BE RETURNED
1. SCHEDULE A PRE -CONSTRUCTION MEETING WITH CITY ENGINEERING DIVISION AT
EDMONDS STANDARD PLANS AN D DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES,
TO THE EQUIVALENT OF THEIR PRECONSTRUCTION CONDITION IN ACCORDANCE WITH
425-771-0220, EXT. 1326. TWO DAY (48 HR) NOTICE IS REQUIRED.
AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND FEDERAL CODES, RULES AND
APPROPRIATE REQUIREMENTS AND STANDARDS.
REGULATIONS:
2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROLNOTES.
- CURRENT INTERNATIONAL BUILDING CODE (IBC) 2019 WSDOT/APWA STANDARD
20. ALL DISTURBEDSOIL AREAS SHALL BE COMPOST AMEN DED AND SEEDED OR STABILIZED BY
SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION WASHINGTON STATE
OTHER ACCEPTkBLE METHODS FOR THE PREVENTION OF ONSITE EROSION AFTER THE
3. CALL FOR UTILITY LOCATES.
DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR THE PUGET
COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC GRADING AND
13 ASIN EDITION)
EROSION CONTROL REQUIREMENTS.
4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING DISTURBANCE
SOUND (CURRENT
OF ANY AREAS OF VEGETATIONOUTSIDE THE CONSTRUCTION ZONE.
2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF
21. THE CONTRACTCHI SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING.
DETAILS, UNLESS NOTED OTHERWISE
WASHING OF THESE STREETS WI LL NOT BE ALLOWED WITHOUT PRIOR APPROVAL.
S. HAVE EROSION CONTROL MEASURES INSPECTED BY C17Y OF EDMONDS CITY ENGINEERING
EDMONDS STANDARD
INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE
3. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHEN EVER CONSTRUCTION IS
22. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED CONTOURS OR SPOT
IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND
IN PROGRESS.
ELEVATIONS SHOWN.
SEDIMENTATION CONTROL PRACTICES AND/011 DEVICES SHALL BE MAINTAINED UNTIL
PERMANENT VEGETATION IS ESTABLISHED.
4. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BYTHE ENGINEER OF RECORD AND THE
23. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT MINIMUM 5% SLOPE FOR A
LOCAL GOVERNING AUTHORITY.
MINIMUM DISTANCE OF 10 FEET.
6. DEMOLISH EXISTING STRUCTURES
S. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF
24. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN SHORING AND
7. CLEAR, GRUB & RO UGH GRADE SITE. REVEGETATE DISTURBED AREAS NOT SUBJ Ec-r TO
"AS-BUI LT" DRAWINGS AN D SHALL SUM MARIZE ALL ASBUILT CONDITIONS ON ONE SET OF
BRACING AS NECESSARY To PROTECT WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS,
ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. (OTHER EXPOSED
REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR PROJECT COMPLETION
UTILITIES ANDOTHER EXIST ING AND PROPOSED IMPROVEMENTS AND EXCAVATIONS AGAINST
AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES BELOW).
AND ACCEPTANCE. A SET OF A5-BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF
LOSS OF GROLhD OR CAVING EMBANKMENTS. CONTRACTOR SHALL ALSO BE RESPONSIBLE
EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCLIPANCY/FINAL PROJECT
FOR REMOVALCHE SHORING AND BRACING, AS REQUIRED.
8. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS, INCLUDING FRONTAGE IMPROVEMENTS.
APPROVAL.
2S. CONTRACTOR,'.': IALL OBTAIN APPROVAL FROM THE CITY AND FOLLOW CITY PROCEDURES FOR
SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION.
ALL WATER SE� . VICE INTERRU PTIONS, HYDRANT SH UTOFFS, STREET CLOSURES OR OTHER
9. INSTALL INFILTRATION TRENCH. EXCAVATION OF INFILTIATION AREAS SHALL NOT BE
6. ELEVATIONS
ACCESS RESTRICNONS. CONTRACTOR SHALL NOT RELOCATE OR ELIMINATE ANY HYDRANTS
ALLOWED DURING WET OR SATURATED CONDITIONS. THE BMP SHALL NOT BE MADE
7. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HEREON HAVE BEEN
W-1HOUT Fini. OBTAINING WRITTEN APPROVAL FROM THE FIRE MARSHAL.
OPERATIONAL UNTIL ALL EROSION -CAUSING PROJECT IMPROVEMENTS ARE COMPLETED AND
FURNISHED BY OTHERS BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND
ALL EXPOSED GROUND SURFACES ARE STABILIZED.
SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE.
26. COORDINATE A0 ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY RELOCATIONS AND/OR
IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE
SERVICE INTERflUPTIONS WITH THE AFFECTED OWNERS AND APPROPRIATE UTILITY
10. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGETATION OF ENTIRE
A CC BRACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND PROTECT
, NNECTIONS TO EXISTING UTILITIES SHALL BE MADE ONLY WITH ADVANCE
COMPANIES. 0
SITE.
ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE
WRITTEN APPROVAL OF THE AUTHORITIES GOVERNING SAID UTILITIES.
IMPLEMENTATION OF THIS PLAN, CONTRACTOR SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE
11. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY EROSION
AND CONDITION OF EXIST NG UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE
27. ALL UTILITIES TALL BE PLACED UNDERGROUND.
CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABIL17ATION AND APPROVAL BY
TRENCHING FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR THE
CITY INSPECTOR.
COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND SITE FEATURES PRESENTED ON
28. EXISTING UTILiY LINES IN SERVICE WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK
THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF CONFLICTS THAT ARISE.
SHALL BE REPARED AT CONTRACTOR'S EXPENSE AND INSPECTED AND ACCEPTED BY CITY OF
EDMONDS ANDOWNER'S REPRESENTATIVE PRIOR TO BACKFILLING.
8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL
CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-555S) AT LEAST 48
29. NEW UTILITY LOCATIONS ARE GENERALLY SHOWN BY DIMENSION, WHERE NO DIMENSIONS
HOURS PRIOR TO CONSTRUCTION.
ARE INDICATED. LOCATIONS MAY BE SCALED FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE
APPROVED BY OWNER'S REPRESENTATIVE AND CITY.
9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE
STARTING WORK AND SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES.
30. T ENCH BACKFILL OF UTILITIES LOCATED WITHIN THE CITY RIGHT-OF-WAY SHALL BE
R
COMPACTED TO 95%. COMPACTION TEST REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO
10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD
PAVING. .
CONDITIONS.
31. WHERE NEW PPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS, PLACE POLYETHYLENE
11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE APPLICABLE)
PLASTIC FOAMAS A CUSHION BETWEEN THE UTILITIES.
AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE CONTENTS THEREOF. ALL SITE
WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS OF THIS
REPORT.
12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO THE RECOMMENDATIONS
OF THE PROJECT GEOTECHNICAL REPORT.
13. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO
VERY DENSE NATIVE SOIL OR COMPACTED STRUCTURAL FILL. IF SOIL IS DISTURBED, SOFT,
LOOSE, WET OR IF ORGANIC MATERIAL IS PRESENT AT SUBGRADE ELEVATION, REMOVE AND
REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT.
14, SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LOCATIONS OF
BUILDINGS, LANDSCAPED AREAS AND OTHER PROPOSED OR EXISTING SITE FEATURES.
15. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS. FOUNDATION DRAINS
SHALL BE INDEPENDENT OF OTHER SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE
STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS.
16. ALL REQUIRED STORMWATER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR
TO INSTALLATION OF ANY PAVEMENT UNLESS OTHERWISE APPROVED BY THE ENGINEER.
17. ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, CATCH BASINS AND OTHER EXTERNAL
DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS NOTED
OTHERWISE .
18. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL
SITE IMPROVEMENTS INDICATED ON THESE DRAWINGS.
SHEETINDEX
C1.1
COVER SHEET& GENERAL NOTES
C2.1
TEMPORARY EROSION CONTROL PLAN
C3.1
GRADING & UTILITY PLAN
C32
GRADING& IITIIITY DETAILS
VICINITY MAP
NIS * = PROJECT SITE
LEGEND
DESCRIPTION
EXISTING
PROPOSED
ABN
BLDG
BOW
OB
CIMP
CO
CONC
CONST
OR
CUYID
DDCVA
DI
DIA
DIP
EA
EJ
ELEV
EDP
EX
FDC
FEE
[FH
FIL
FT
GV
RIP
HT
ID
IE
L
LOPE
LF
UP
LT
MAX,
MECH
MH
ABBREVIATIONS
PROPERTY LINE
ABANDONED
MIN
mi
MON
NIS
OC
PC
PI
PIV
PT
PVC
pVI
PVMT
PVT
R
RENE
RJ
RET
RT
SD
SECT
SDMH
SIM
SO.
SS
SSMH
STA
STD
STL
T8
TOC
TOW
TOP
TYP
VC
W/
WM
MINIMUM
ADJACENT PROPERTY LINE
BUILDING
MECHANICALJOINT
CENTERUINE
BOTTOM OF WALL
MONUMENT
CLEARING LIMITS
CENTERLINE
NOTTOSCALE
SILT FENCE
Ax� Ax-
- X_ X_
CATCH BASIN
ON CENTER
CONTOUR LINE
- - 100 - - - - -
IR-
CORRUGATED METAL PIPE
POINT OF CURVATURE
FENCE
E] _0_____o_
0
CLEANOUT
POINT OF INTERSECTION
SANITARY SEWER LINE
ss -
_ss_ss_
-7
CONCRETE
POST INDICATOR VALVE
MANHOLE
0
(@
CONSTRUCTION
PROPERTY LINE
STORM DRAIN MAIN
SD- SID -
SD -SD-
CONCRETE PIPE
POINT OF TANGENCY
STORM DRAIN PIPE
- - - - - - - - - -
CUBIC YARD
POLYVINYL CHLORIDE PIPE
ROOF DRAIN
R R -
-R-m-ll
DOUBLE DETECTOR CHECK
VALVE ASSEMBLY
_�O_INTOF VERTICAL
INTERSEC"ON
FOOTING DRAIN
F - - - F - F -
F-F�
DUCTILE IRON PIPE
PAVEMENT
PRESSURE LINE
P - - - P - - - P
-P-P--,
DIAMETER
POINT OF VERTICAL TANG.
CATCH BASIN (TYPE 1)
0
DUCTILE IRON PIPE
RADIUS
CATCH BASIN (TYPE 2)
EACH
REINFORCEMENT
CLEANOUT
EXPANSION JOI , NT
RESTRAINEDJOINT
CLEANOUTANDWYE
ELEVAT16N
RETAINING
GRADE BREAK
- - - - - - -
-
EDGE OF PAVEMENT
RIGHT
SURFACE SWALE
EXISTING
STORM DRAIN
DRAINAGE ARROW
FIRE DEPT. CONNECTION
SECTION
WATER UNE
WA- - - WA-
-WA-WA-
FINISHED FLOOR ELEVATION
STORM DRAJN MANHOLE
WATER METER
El
N
FIREHYDRANT
SIMILAR
FIRE HYDRANT
FLANGE
SQUARE
FDC
FEET/FOOT
SANITARYSEWER
Plv
o
GATE VALVE
SANITARYSEWER
MANHOLE
GATE VALVE
x
x
HIGH POINT
STATION
TEE
�T
HEIGHT
STANDARD
SO. BEND
INSIDE DIAMETER
STEEL
THRUST BLOCKING
A
INVERT ELEVATION
THRUSTBLOCK
CAP
UENGTH/UNE
TOPOFCURB
CONCRETE PAVEMENT
LINED CORRUGATED
POLYETHYLENE PIPE
TOP OF WALL
ASPHALT PAVEMENT
LINEAL FOOT
TOP ELEVATION
CRUSHED SURFACING
........
LOW POINT
TYPICAL
ROOKERY
LEFT
VERTICALCURVE
SPOT ELEVATION
/-20.0
/-20.0
MAXIMUM
WITH
7 - - - T -
-T-T-
MECHANICAL
WATER METER
POWER LINE
- E - - E---E-
-E-E
MANHOLE
GAS LINE
- G - - - G- - -
SIGN
COMPLIES WITH APPLICABLE
CODE
4m
0
GNIGINErEIRING
250 4TH AVE. S., SUITE 200
EDMONDS . WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
CIIIII19
gg
th Z
DESIGN: VID
DRAWN:
ATD
CHECK:
JPU
JOB NO:
18044.20
DATE:
08/21/18
Ld C-4
0 Ld
0 Lai 00
z
LLI > a) Lu 0
<
0 < LLJ Z
F
cn 0 3r
LLI Z 0
Q� N (f�
r� <
< af
:2 04 Z LIJ Ld
Q� - 0 > z
< r, M
m: Lo 25 0 LLI
m - uj 0 (D
T..
JAN 2 3 2019
BUILDING DEPARTMENT
GITYOFEDMONDS
Q)Lzam�-no
sw 1:/4, SECTION 5, TOWNSHIP 27 NORTH, RANGE 5 EAST, W.M.
PK;y
g,� "gh "-,/PN= E DE4' 1� -I
4' GAP IN �EWEII I o.: y
DUE TO TRE EST/Of NORTHFAXTH I fIR
6j[Wgib PROPERTY/CORN R P R W
5 1 qRDTE9T
-FEgCi Z. RAN P
ANrE TEC IVEIBI F�NC(NG
'7
BFP Ff9dE LIA 13 WINE. .05
LIMITS 91 WV . I INSTALLT MPORARYCB
M IMTAII qil-T4FNCE
2
�w,
N..'. NP morECTIONALONG 0(
72NDAV WTYP
X
REMOVETREESWI INIUMfTS EY SSMH
N882W 25,
t OF TARINP & GR INIS, 7YP M=2793C
IE=269.33' 8"N
R
]E=268.V 8"S
'o
EX CO
T\
QSTALLSTRA
WATTLE,
IF
V 'R.
GARAG
EN wz-
/Z EMOVE 1�1(
VA�VES
V�
EM POLE
AN A(.� ON EXISTING OUTLET
RIM: 256.5
SFR wIll I I
6" IE- 253 0 (W)
IR SWALE W/ ROOKI/
IINTERCEPTC
I I CHECK DAMNI 501
Su\m ROOM
�ND
INSTTAI ORA B
NLE
PRO E
A
±1.5 \NOCKER�Y - S-VABII
NSTRU TR
b CB
RIM' 216 C
IE-213 81' 6 1 C NE
\IE=21�.2
kE=21 �5�115IA `SE:
j
SO �Q
50-I -240--,
ii� 00 0 "N
6
01
_236--�
%
ts-
N_� . . . . . . . . . . ....
SW
V v
1po)c,
"k
NOTES:
!.-INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS
STAN DARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION.
2. ALL DISTURBED PERVIOUS SURFACES SHALL BE AMENDED TO MEET DOE EMP T5.13.
3 C NTRACTORTO VERIFY LOCATIONS OF EXISTING UTILITIES.
41 REOFER TO SHORT PLAT CONSTRUCTION DRAWINGS FOR EXISTING UTILITY EASEMENTS AND
STORMWATER IMPROVEMENTS. (AFN: 20161209SOD1).
S. FROM OCTOBER IST TO APRIL 30TH, ANY EXPOSED SOILS NOT BEING WORKED FOR MORE THAN 2
DAYS SHALL BE COVERED. FROM MAY 1ST TO SEPTEMBER 30TH, ANY EXPOSED SOILS NOT BEING
WORKED FOR MORE THAN 7 DAYS SHALL BE COVERED.
6. OBTAIN A I" WATER METER PRIOR TO CONSTRUCTION. A HOST BIB W/ ATMOSPHERIC VACUUM
BREAKER WILL NEED TO BE INSTALLED AT THE BACK OF THE WATER METER BOX PRIOR TO
CONSTRUCTION.
7. INSTALL TEMPORARY I NUET PROTECTION TO ALL OR INLETS DOWNSTREAM, IN ADDITION TO
LOCATIONS DEPICTED ON PLAN._
r__11:211.56'(12'0)PVC N,S
CB
\7
EX CB
E=278.05'�4"O)PVC E
EX CO
=
:2
:'211:11: p C
EM
�12 1, SN
MA
FLOWUNE OF
THICKENED EDGE
ciI
-�oo
oc)51
PROTECTTREiWt
,ORANGE
. . . . . . .
I PROTECIFIVE
UI%FENONG—
RiM=262.66'
IE=255.76: 2:�,.'�PPll
SN
Ex CB
TW=260.—
E=264.22';4"0)pvC E
E=263.02'�24'0)PVC S
SSMH
RIM=260.10'
IE=250.03' 8"N
IE=N9.94' 8"S
EX CB
RIM=255.9F
2:,0 VIC I
:E:21,1:,Il
E " �P
IE=251.94- 6-O)PVC E
LPV3
20 0 10 20 406
GRASS OR ROCK
LEVEL BOTTOM I
2
ROCK CHECK DAMS TO BE
PLACED AT S0'OC ALONG
LENGTH OF INTERCEPTOR DITCH.
.SEE DETAIL 7 ON THIS SHEET
�NTERCEPTOR SWALE
RTTI
2' . 2' WOOD/STEEL
FILTER FABRIC SECURED
TO 2" . , '14 GA
MAE FABRIC EQUAL.
NNOVE 8,41-
FUTE FABRIC "TERIAL IN CONTINOUS ROILLS
FABRIC TO WIRE
r . III WM./BTEEL -
WIRE MESH FENCE
TO SUP ORT FILTE
AID
�SOTT
MAUAIAL 6' 70 'l,
NOTES:
I� CONTRACTOR/DIEVELOPER $HALL MAINTAIN AND ENSURE PROPER
EROSION CONTROL THMUGHOW FRWFCT- C Y EC"ON REOUIR
2, SILT FENCE TO 01 PLACED DOWNSLOPE OF CONSTRUCTION ArLL, BREACH CONI MEIHODS
ACTWITY. E R. CTH�R WO K IAN IN
FILTER FABRIC FENCE IN= 2016
CITY OF EDMONDS FILTRATION SYSTEMS —
PUBLIC WORKS STANDARD
DEPARTMENT DETAIL
APPAWED BY; A. ENDUSIN
CITY STANDARD DETAIL
t'/�NE. N�Tl
GRACE
mum-M.—
(TYP)
.1.
NOTES -
I. GQ__.R/w_Cm .- MAINTAIN
THIS APPLICATION AT ALL TIMES DURING
CONSTRUCTION FERIOD,
— EMMENT' IN CATCH —1. INEERT
SHALL BE INE-I WHI INSERT It
.N_PG FULL.
3. DITY --SI FIMIR ON ALL.
EACEW OONMOL MLTHO S 01
_fN WORK CAR BEGIN.
TEMPORARY
MSION DATE
C
4�R,
SEDIMENT TRAP
JANUARY 21118
STANDARD
PUBLIC WORKS
FOR CATCH BASINS
DEPARTMENT
DETAIL
,
ER-902
—ED - A.
2W MtH RADIUS
S' M 'U
QUARAD, SPALUS
2-41" MIN Dth
le MIN DEATH
i IS'
s' mm
OrFULL
'IN..A ESS/EXPEAS
DETAIL NOTES
ID THE MINIMUM LENGTH SHAUL. BE E)QlADED AS NECESSARY TO ENSURE WTEFHAL IS NOT TRACM OFF MAE
AND/OR INTO THE PUBLIC RCHT-CF-WAY.
(D — WIWAA1 —1 AND/C. EAE —E.E AM 15' WIDE NIN. $EE TABLE BEE- FOR REQUIRED
NOTES�
1. SURFACE WATER - All SURFACE WATER FLOWDAD OR DIVERTED 10AAAD COIACTON ENTRI SHALL BE IPED
ACROSS THE ENTRANCE. IF PIPING IS UPRIUCTICk, A MOUNIABLE BERM WITH SIT SLOPES WILL BE PERMITTED.
2. ARWEMANCE _ THE NTRANCE SHAU. BE MAINTAJNED IN A CONDMON WHICH MUL PREVENT TRACKING OR FLOWING
OF SEDIMENT OFF SITE AAD/Ok ONTO PUBLIC RXINT-OF-WAY. THIS MAY REQUIRE MIMIC TOP DRESSING WITH
ADDITIONAL QUARRY SPALLS AS CONDITIONS DI AND REPAIR AND/CR CLEWOUT OF ANY MEASURES USED 10
IMILENT. ALL 11D"ll SPfUlD, DROPPED, WkEHED OR TRACKED OFF SITE AMDIOR ONTO PUBLIC
A- I.MIDATELY.
3. YAR U-S SMALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO UEMA NG THE SITE WHEN RUSH ING IS USED IT S HALL
SECIME4 TRAPPING
DEVICE.
4. IMSPECIH)N AND NEEDED MAINTENANCE SHAUL BE FAMED AFrER EACH RAIN.
r —PRWECr MIN LENGTH OF DEET) I -PROVIDE ATs OR ASPHALT
TRANS N MIRI 110WAll
AM 1. AN AR EAA_
Ull TO BE DETERMINED
_AE w eft INSPECTOR. BY INSPECTION REQUIRED ON
AERE ALL EROSION CoNI Mu2ol
U. I
RE V_
FORE ".
STABILIZED CONSTRUCTION
ISOM DATE
Rr 2DII
CITY OF EDMOND
ENTRANCE
STANDARD
PUBLIC WORKS
DEPARTMENT
DETAIL
ER6011
'PlA611D.' A EI
:�3�,(
ITY STANDARD D ETAI L
rLE: NTS
CONTOUR LINE
cryp) AN— IANA,.
111;1
%IYp) 2'�'' UN -TREATED
WOODEN 61AKE
M)
--D.. SIDE - QTE2 �- IAN
4' MAX
2* WIN
:,�GER
OVERLAPS 4.40 E,
2*.2'�4 - UN -TREATED
WOODEN STAXE ((TYP)
DIAMEn
WAI F nEtAII
AREA, AMM LE FDA
SEE YAOTTUE S
TABLE (TYP) V DIAMETER WArFLE
SPACING TABLE
SLOPE MAXIMUM SPACING
WATTLE
SEE DETrL imil, W-w
2HAV
4HdV 4W-0-
WATTLE IN SIM �4NRIY ONE RUN MY
NOTES,
1. COMPOST DITTIES REOOMIMMDEO ON SLOPES� USE STRAW WATRJES IN PAYMENT APPLICATION.
2. ON SU)P0, INSTALL WATTUES PERPENDICULAR TO THE FLOW DIRECIIONI AND PARALLEL TO THE SLOPE CONTOURS.
INETAUUM. SNALL WE IN ACCOREANCE WITH WSOCT STANDARD SPECIFICATION .-.1.300).
3, A NOFF 6NALL HIM RUN UNDER OR AROUND RI ADDITIONAL STAXNA) MAY BE NECESSI TO PREVENT
UAD_
4. WATTLES $�ALL ES INSPECTED REGULARLY, AND IMMEDIATELY AFTER A RADII PRODUCES RUI REMOVE
SEDIWI AID ACCUMULATIONS W14EN EXCEEDING 1/9 HEIGHT 8EPREEN THE TOP OF THE WAFFLE AND THE OROUND
_E.
CITY OF EDMONDS '
WATTLE INSTALLATION
="l 2M�Tl E
STANDARD
PUBLIC WORKS
DEPARTME14T
. DETAIL
ER-903
APPROVED &� R. immus.
I,- , -\ LI I Y b I AINJ UAKU Ut I Al L ('r.) ULPARTMENT OF ECOLOGY DETAIL
kZ.,r- _SCAIENTS SCALE: NTS
RESUB
JAN 2 3 2019
BUILDING DEPARTMENT
CITY OF EDMONDS
2" TO 4" QUARRY SPALLS
2" TO 4
7 A
B A
SECTION A -A SECTION B-B
r,-'\ ROUCHECK DAM
SCALE: NTS
I
ENSINIEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
0111119 1
ISO
z
CL 7A m
DESIGN: VID
DRAWN:
ATID
CHECK:
JPU
JOB NO:
18044.20
DATE:
08/21/18
_j
0
0
0
z
0 V)
0 _j
C14
0.<
Lj 0
0 Li 00
LLj Ld
z
LLJ >
LJ Z
04
P..
<
a
0
C14 Z
CL Z
X_ in 0
Ld
v) — Li
SHEET:
C2.
SW 1/4, SECTION 5, TOWNSHIP 27 NORTH, RANGE 5 EAST, W.M.
;M�
2 )Pvq N,S
4- oz
OF HAJli'UNK;FENCIi' 7, 7 1
I - DE
/+4- GAP IN FE9E 'RI 'O',�C6F/ I
PROPERTY LIN I
V420' 0
4' GAP IN FEN"/ 11DWU & 1NFST/OF NdRWbAk1ZSg./5 0 4�'DIA PERFORATED PVC PIPE
r'D P'
LIE I. TREE/ I N N Y� t - 2
RwERIy/(;0F6 0 7
-FE CE / / I I
624.70 W-��N�%.L` URBED SOILS. LAWN BETWEEN W TH G'OF I'MINUS GRAVEL 8" MIN FROM WOOD.
qG=1 0 6 'S
I I / / FG= I IOUSE. PLANTER BED ALL AROUND, WRAPPED IN SEE STRUCTURAL DRAWI
.... !�BETWEEN I ALLS AND PROPERTY LINES
W,
B *zg,- F�f E WIR WC 7 NON -WOVEN GEOTEXTILE FABRIC,
TOW=277.6 av I � i SLOPE AT 0.5% MIN. TURN DOWN
ASP ALT THICKENED EDGE TO PERFORATIONS AS SHOWN
rz-2 7. 0 BOW=267.b AY TO ()o
V TO 0 2.4
Eb
EG=252�4 FINISHED GRADE
7.7.0 HALT THICKENED EDGE
RIM=279.74 MIN. PLACE NEXT TO FOOTING
T6W=275!0 PER' !!�j I
� 0 E=2 9 33' 8"N DRAIN OR AS SHOWN ON
I IN 6" DOWNSPOUT TIGHTUNE TO 4
EX S.SMH CONVEYANCE SYSTEM @ 0.5%
TYP
BOW= U)RA
-F 2.66.6
i A ING iE�2(,8.83' B"S GRADING & DRAINAGE PLAN
(CONTRACTOR MAY LOCATE ON 4" MIN CONCRETE
�D EG=2�15.0
7 �277 D EITHER SIDE OF FOOTING DRAIN) o (BROOM FINISH)
FINISHED GRADE
j 7. �E 279.5 NOO DO
BOW 252.0-- Zi E=2fq.56'(I2"0)PVC N,S 4
N �Ul �NMFJTI MATERIAL --------- SURFACING
TOP COURSE
IJ PER F E=277 3 )o
_11RAGEfFE=n ACCEPTABLE TIGHTLINE
or EX CB
SDR 35 0 'E' us 2
P
SCH 40 LINE OF MAX EXCAVATION. DO �0 4
t /4 ENTRi`
N-12 IF SOIL IS OVEREXCAVATED, 0(60a oo 4'�
KY REPLACE WITH LEAN MIX o o SUITABLE NATIVE MATERIAL
0 EX C8 FBIO HANGOR CONCRETE FILL' , TOP 12" COMPACTED TO A
MIN I M U M OF 95% RELATIVE
DO.32�(8"O)PVC S NOTE: COMPACTION USING AASHTO
MY 7 'COVER FOR PIPE UNDER FOOTING T-180 (ASTIVI D1557).
T�7 07' b
u DRIVEABLE SURFACES AND UNSUITABLE NATIVE MATERIAL
UNDER LANDSCAPE AREAS., SHALL BE REPLACED
TYPIk I I
278.05'�4'0)PVC E
iE=2;6.25' 24-O)PVC S
\91 2:E 0.
to Ep _-� FOOTING AND ROOF DRAIN SECTION TYPICAL CONCRETE SECTION
x (61 1 0 ENTRY , PG
46 DRY UTILITIES TO
258. 6 0 SITE OFF EXISTING SCALE: IS
B6
266., ... 47 4.
DRY UTILITY TRENCH
9.50 EX CB
RIM=270.63'
GARAGEN j KY E-264.38:(12:0 Pvc N NOTES:
7.0 1. POST CONSTRUCT ON SOIL AMENDMENT IS REQUIRED ON ALL AREAS
1�=267.53(80)PVC NW NOT COVERED BY IMPERVIOUS SURFACE WHERE SOIL IS DISTURBED
ATTHE END OF PROJECT, ALL DISTURBED AREAS MUST BE AMENDED PERTHE SOIL DURING CONSTRUCTION.
2. SOIL AMENDMENT MUST PASS A 12 INCH MINIMUM PROBE TEST.
FLOWLINE OF AMENDMENT DETAIL AND PROBE TO 12-INCHESAT THE SITE FINAL INSPECTION.
DEFINITIONS:
EM POLE THICKENED EDGE
0,\ PLANTING BEDS
t, TURF (LAWN) AREAS
CO�� - , , I NON -DISTURBED AREA (ND): VEGETATED AREAS THAT WILL NOT BE
'd U SUBJECT TO LAND DISTURBING ACTIVITY (SEE D) DO NOT REQUIRE SOIL
\�FR ?t1A\1 2"4" MULCH' GRASS: SEED OR SOD AMENDMENT IF THEY ARE FENCED AND CONTINUOUSLY PROTECTED
Y. 44 dy
THROUGHOUT CONSTRUCTION. THE FENCING MUST BE IN PLACEATTHE
a"
SUK ROOM\ Y( 7 7 FIRST GROUND DISTURBANCE INSPECTION. NODISTURBANCE,
)R rvf�Tt
zNu TLU K B1 OT INCLUDING VEHICLE TRAFFIC OR MATERIAL STORAGE, IS ALLOWED IN
G' PVC 0 2% MIN
66 LF THESE AREAS UNTIL FINAL INSPECTION.
3" OF COMPOST . .. . .. 13/4utwrnvubi
INCORPORATED INTO - - - - - - - - INCORPORATED INTO
SOIL TO 8" DEPTH SOIL TO 8" DEP1. S -NTAREA(SA): AREA (TURF AND LANDSCAPE) THAT MUST
..............
- - -- - -- - - ------ ....... AMENDED PER THE SOIL AMENDMENT DETAIL AND BE LOOSENED SO IT
x CR WILL PROBE TO A DEPTH OF 12 INCHES PRIOR TO SITE FINAL INSPECTION.
3 _A�Zll Tl� 1S INCLUDES AREAS IMPACTED BY CLEARING AND GRADING,
Q_ I --------
INCIFF FROM DRIVEWAY !E=2,5.7-T!!2"0\,PVC N 8.
SUBSOIL SCARIFIED 4" SUBSOIL SCARIFIED 4" STOCKPILING, SITE ACCESS, PATHWAYS AND MATERIALS OR EQUIPMENT
.07 CIS IN SHARED PRIVATE ZNC DRIVqF IE= 255-86 ';I2"0)PVC S BEL, BELOW COMPOST STORAGE.
4 DRIVEWAY 111=256.46'1,�I�O)PVC HE AMENIDDEWD 1COYMERP(O.S1 AMENDED LAYER (I'll
BELOW SOIL SURFACE), BELOW SOIL SURFACE),
OR AS DETERMINED BY 12" OR AS DETERMINED BY
SSCOIE_-25216 \j" EX IB -_ THE CITY THE CITY
M - 216 3 RIM=266.X
C3. b.'tWMLUEAN0UTSH
AV E=264.2214"O)PVC E
�E 2 3 �6� 'C NE H E 2211 CAST IRON -�24_0)PVC S
IE=2 3 8 C NE\
ST E=263.02
CAP
W
I �2 LAIAPHOUIE COVER W/1)�
H EX BO Llr�
.5 '1 50�CqP 'SE
WM SOILAMENDMENT
vv SCALE: NIS
So
EX SSMH'
\313 L�-KV'\NC'�� RIM=260.10'
0 IE=250.0� 8"N
C
EXTEND TRIMMER BARS FULL
[E=249.94' 8"S
LENGTH OF ADJACENT REINF
JE WNE-OITNEF.-ORCI N G FO R Cl RCU U
(TO SUPPORTS) IR ENINGS
-236 STREET Ir,4tROVEME EX CB OF
SHALL BE IDENTICAL TO REIAN.."
\COMBUMDA�PARTO
N RIM=25515
OPENINGS EXCEPT AS NOTI
y,.CB_ - CORNER BARS:
M=zM PVC W
tM;,z 180' IE=251.94(6-0)PVC E (1) #6 x V-13" FOR WALLS W/ (1)
LAYER OF REINF OR (2) #6 x V-01'
.0 .1)CP
127@
FOR WALLS W/ (2) LAYERS OF
REINIF TYPICAL AT EACH CORNER
HOOK TYP HORIZ AND VERT
GRADING AND UTILITY WALL REINF AROUND TR MMER
it
BARS, TYP
SCALE: V=20'4- N
20 o 10 20 40
NOTES:
17 MALL DISTURBED PERVIOUS SURFACES SHALL BE AMENDED TO MEET DOE OMP
TS.13. SEE 4C/3.1
2. 3'SEPARATION IS REQUIRED BETWEEN THE DRY UTILITIES (POWER, GAS,
PHONE, CABLE, ETC.) AND SEWER, WATER AND STORM AND 5'FROM ANY CITY
MAIN UNES. A MINIMUM OF 10'OF HORIZONTAL SEPARATION IS REQUIRED
BETWEEN WATER AND SEWER LINES.
3. DRIVEWAY SLOPES SHALL NOT EXCEED 14%.
4. ALL FINAL RESTORATION SHALL BE COMPLETED BY THE CONTRACTOR, NOT THE
CITY OF EDMONDS.
S. CONTRACTOR TO VERIFY LOCATIONS OF EXISTING UTILITIES.
6. REFER TO SHORT PLAT CONSTRUCTION DRAWINGS FOR EXISTING UTILITY
EASEMENTS AND STORMWATER IMPROVEMENTS. (AFN: 201612095001).
7. BED & TRENCH PIPING PER 2C3.2 & C3/C3.2.
8. WATER METER MAY BE USED FOR WATER ACCESS DURING CONSTRUCTION
BUT A NEW WATER MAIER SHALL BE INSTALLED TO ACCOMMODATE FIRE AND
DOMESTIC SERVICE.
9. TRAFFIC CONTROL NEEDS EXPECTED TO BE MINIMAL FOR UTILITY PATCHING.
SEE S/C3.2 & 6/C3.2 FOR SHOULDER WORK AND LANE CLOSURE ON LOW
VOLUMEROAD
10. FIRE SPRINKLER CONSULTANT TO VERIFY WATER METER AND SERVICE SIZE,
11. WORKED SLOPES S14ALL NOT EXCEED 2:1.
12. WATER SERVICE LINE TO BE INSTALLED PER CITY WATER SERVICE LINE
HANDOUT E-86,
13. ALL SEWER TO BE GASKETED SDR 35.
WALL CALLOUT LEGEND
TO =TOPOFWALL
BOW=FINISHED GRADE AT BOTTOM OF WALL
(DOES NOT INCLUDE FOUNDATION DEPTH)
EG= EXISTING GRADE (PRE SHORT PLAT)
TOW MUST BE �3'ABOVE EG
REFER TO STRUCTURAL FOR WALL DESIGN
IMPERVIOUS SURFACES MAXIMUM PRIVEWAY SLOPE
Z
ROOF 2 667 SQ FT AULOW0 14% Z
DRIVEWAY 1:!i3O SQFT 12
0 HOOK OR BEND
WALKWAYS 2,610 SO. FT TRIMMER BARS: BARSWHERE
TOTAL 6,807 SQ FT PROVITE 1/2 -OFREINF IMPOSSIBLETO
INTERRUPTED BY OPENING I ... EXTENDTO THE
AT 3" OC EA SIDE. SPECIFIED LENGTH
FC 17R RTIFS:
GRADING QUANTITIES
TOTAL EXCAVATION (CUT) - 700 CU YOS TOTAL
EMBANKMENT (FILL) - 7SO CU YDS 10'1'111A�11 W/ (1)
LAYER OF REINF OR (2) #5
TOTAL 1,450 CU YDS FOR WALLS W/ (2) LAYERS
THE QUANTITIES SHOWN ABOVE ARE FOR THE PERIVITFP.RCIOESS OF REINF LAP 24'MIN
ONLY. THESE VALUES ARE APPROXIMATE, DO NOT USE It
BIDDING, PAYMENT, OR ESTIMATING PURPOSES. TYPICAL REINFORCING AT WALL OPENINGS
- I -
\-zw/ L :
OMERIC09TRACTOR RESPONSIBLE
FOR WONTING ALL ON -SITE UTUT73.
RELOCATION/REVISION TO ANY UTII
MAY REWIRE SEPARATE PERMIT
Applicant shall repair/replace all damage to
Utilities or frontage improvements in City
fight -Of -way per City standards that Is caused
or occurs during the permitted project,
OWN:RICONTRA.CTOR ISRESPCHSIBLE FOR
EROSION CON11MUL AMD DRAMAGE
e
6NIGINIIEBEIRING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
01111119 1
r
Z
DESIGN: VID
DRAWN:
AID
CHECK:
JPU
JOB NO:
18044.20
DATE:
08/21/18
LLJ
D
0 0
L�j 00
0
z
>
<
C, 3�:
LA Z
C)f C-4
0
r, w
< 0
M 04 Z
0
<
:�
m: LO M
ICY-
(f) - LLJ
0
SHEETRESUS
APR 0 3 2019
BUILDING DEPARTMENT
CITY OF EDMONDS
C';3.1
RESIDENCE
10M VHI
X TO EXCEED IN' BETWEEN CLEMOUTi
C OUT (WYE WITH
CAP
AND CLEMour covER,
LEVE
CONCRETE "No COCD
R
111111 1 COVER
SEE NOTE 3
-12 HED GRADE
/11"
END Or PIPER GRIPPER POLO
(CMERNE 27061 OR APPROVED
EQUAL)
WATER TIGHT CAP
45' T-\RISER
LIVIVILING COLLARV I
SEE NOTE 4
4S'
12' PVC SLELVEJ
0* RISER
4- �R El" !IDE $MR
AN
V WYE AND
r CITY STUB
GENERAL CLEANIOUT DETA[
48' SENIDL
4* OR 6"
LOCKING CORR
SIDE IEWER CLEANOUT DETAIL
'AS'PN`AL,TSU,RFACE
LEVELLING COLLAR
NOTES,
SEE
1. SIERRA PIPE SHALL BE SOR-35 AND 40INTS SMALL BE
CASKETED'
2. PIPE SLO E TO BE 29 MIN AND UP TO SOX MAY.
3, BEAR CLEANOUT COVER TO BE EAST JORDAN IRON WORKS
GIS�R
1 '007 LONO 12, PVC
FO
PRODUCT 000386102 STAR PIPE COSP4aL OR APPROVED
1
EQUAL.
S'
OF TV
OF PIPE GRIPPER
4, LEVELING COLLAR SHALL BE CONSTRUCTED AS FOLLOWS:
P PUB
LUG (CHERNE 270261
Pit
OR APPROVED EQUAL)
IN ROADWAYS PER COE BID DWO OU-424
TYPICAL CLEANOUT
IN SIDIDNALKYLIENDSCAPED AREAS, ENER,24mx24`%G`
PUP CONCRETE COLLAR OR 24" DIAMETER It V DEEP
I ME
COMOR Lvp
ETE CO
1113111IONE DATE
OF EDMONDS SEWER
CLEANOUT DETAILS
JUDDI .. ...
0CITY
PUBLIC WORKS
I
STANDARD
DEPARTMENT
DETAIL
,
APPROVED BY., R, ENGLISH
SS-200
SW 1/4, SECTION 5, TOWNSHIP 27 NORTH, RANGE 5 EAST, W.M.
"" LONT S.- BE AL H— STRAIGHT
.HE. ALL MSED VERTICAL EDGES
CLASS 1/r
PIT 6 -22
/.E TACNE. HEATIL, PER WSOOT CARD
SPECIFICATIONS 5-OHL A APPROVED
(SEE NOTES 4 AD 5)
j"NIA
OR APPROVED RQUAL0 SEALED PERIACK
YESDOT M ne C. SLOPE EXCASCOLION
To AVOID ON ERM13020 EXISTINO PAVEMENT.
. ..........
EXISPIN
;%
....... ..
..... ...... ...........
............... ......... ..........
EXISTING
'4
is
IMPO' OR
FIT NATIVE MATERIAL
CRUSHED S R E BASE
COURSE E S
SAG
To WILL $HALL BE COMPAM
DSIC MAXIMUM DINSITY
$PLC 9-C 9( 1
�SEE NOTE 2)
(SEE N C
TRENCH WIDTH
NOTES,
1, SEE CRY OF EDMONDS MODIFICATIONS 70 DIVISION I OF THE CURRENT WSDOT STANDARD SPECIFICATIONS FOR
RACIFILUNG REQUIREMENTS.
2. S OMIT PROCTOR AND DENSITY TESTS FROM CERTIFIED TESTING COMPANIES DOCUMENTING THAT THE BACTERIA.
MEET$ A MINIMUM OF 959 DENSITY PER ASTM 0 1557,
3. GSBG DEFIEH SHALL BE A MINIMUM 0' OR MATCH EXISTING WHICHEVER IS GREATER. WHEN MATCHING EXISTING
CSHC CIPI GREATER THEN B", THEN CSOC SNELL HE INSTALLED IN MULTIPLE EQUAL THICKNESS LIFTS NOT
EXCEEDING 6".
4. ROADWAY HIM DEPTH $11ALL BE A MINIMUM OF 4' THICK UNLESS APPROVED BY THE ENGINEER, ANY WIN
GREATER THAN 4' SHALL MATCH IDOSTTNG�
S. ALLEY "VON DEPTH SMUL BE A MINIMUM OF 2' THICK, UNLESS APPROVED By THE ENGINEER, MY DEPTH GREATER
THIN V SHALL MATCH EXISTING,
8, UNLESS APPROVED BY THE ENGINEER, THE HMA SWILL BE INSTALLED IN MULTIPLE EQUAL IHICHNISS UFTS N07
EXCEEDING 2'.
7. FINAL PAVEMENT JOINTS SHALL BE NEATLY AND UNIFOAMILY SEALED warm WSDCT VANDARIS 5�jcIFICATIOHS
APPROVED JOINT SEALANT OR APPROVED EQUAL,
REVISION DATE
CITY OF EDMONDS TYPICAL HMA AND JANUARY =IS
UTILITY PATCH -
PUBLIC WORKS STANDARD
DEPARTMENT DETAIL
,� 4'' " , I APPROVED BY. A. ENOUSH GU-41 0
ir MIN
8' MIN
8' MIN 1— -1 e WIN
SEE NOTE 1-
-SEE COE SPID OIL CU-410
BEDDING MATERIAL 'Va'
CRUSHED, PER COE Go M.UISI'15.0.1
OR SUITABLE ED ED MATERIAL AS
APPROVED BY City EN INEER
(SEE MOTE 2 BELOW)
FO�MPATIQNI (IF REQUIRED)
UQIESG
1. MAXIMUM WIDTH OF TRENCH AT TOP OF PIPE
30* FOR PIPE UP TO AND INCLUDING 12- DIAMETER
0 D. PLUS 18" FOR PIPE LARGER MAN 12' NOUINAL DIAMLIER
2. REFER TO CITY OF EDMONDS MODIFICATIONS TO DIVISION 9 OF WSVOT STANDARD SPECIFICATIONS FOR
MATERIAL
GRADATION AND ADDITIONAL INFORMATION.
1 TRENCH BACKFILL SHALL PEET A MINIMUM COMPACTION OF 95% DENSITY PER ASTMI 0 DEST.
4. IF UNSTABLE MALTERIAL IS ENCOUNTERED BELOW PIPE ZONE. CONTRACTOR SHALL REMOVE AID REP E AS REQUIRED
BY CITY ENGINEER.
REVISOR DATE
CITY OF EDMOND§
TYPICAL TRENCH SECTION
JANUARY 201.
PUBLIC WORKS
STANDARD
DEPARTMENT
DEFAIL
APPROVED BY: R. ENGLISH
GU-400
AN FRAME AND COVER PER
2" TO 12' CONGO RISERS
COE SITE OIL GU-420
(e MIN - 18" MAX)
USING NOR SHRINK GROVE
PROVIDE SM ON FINISH
IN IDE AND OUT
to- to
2� MAX
' 'ANPH Los
SEE COE STD OTL� GV-423
L
POL�EOUPYUDME SAFETY
ECCENTRIC PRECAST
STEP/LADDER 12" BE
PRECAST SECTIONS
4" MIN THICKNESS
2- TYP
Z
FLOW
48' OR
54*
SAND COLLAR
_N
OR KOR -SEAL
MANHOUE DMOC
STEPS
FlUIM AND
COVER
NOTES:
I B" MAX
t � LOCATE MH LID OUTSIDE THE WHEEL PATH OF THE
ENJOY
TR am ...........
AVEL LANE.
4 CHAIN
2. BASE REINFORCING SHALL BE #4 RESAR AT 12" OC
SHELF
BOTH WAYS,
D� LARGE' MH TO BE REVIEWED ON A CASE BY L CASE
BASES USING APWA STANDARDS.
B" MIN
4. STEP AND LADDER MAY BE USED IN LIEU OF
POLYPROPYLENE SAFETY STEPS. SEE COE SIDE, DTL
MIN 2' CLEARANCE
GV-423.
.-IS:0N.o�,ATE
CITY OF ED
TYPE I MH
ARL
STANDARD
PUBLIC WQRK1
DEPARTMENT
DETAIL
GU-421
APPROVED BY! R. ENGLIS14
CITY STANDARD DETAIL EIIY�!TANDARD DETAIL
I -LE: NTS CITY STANDARD DETAIL CITY STANDARD DETAIL
SCALE: NTS 4 SCALE: NTS,
G)
Figure 6H-3. Work on the Shoulders (TA-3) Figul.611,11. Lane Closure on aTwo-Lane Road
G I RAIDE-\ ED.O... LEAVE with LOWTraffic Volumes (TA-1 1)
T-
rif ltla Y`_EE
0 L'Pti ... 1)
ShadWertwer
M 7VALVE OM ! 1 10 "lli-
Isse Note 7)
I.L
T
NN
A -4
%
Li BaRrsp-owl ... 1)
S'NOULDER>
<
MATERIAL LI
7: 84L CORP. STOP WITH Cc THIDD INLET AND COPPER (CIS) CRIP OUTUT (FORD OR MUELLER)
0 a P RPOSE UNION
MIPT X DES GRIP SALL �C CUPS STOP EQUAL To FORD I4-.4,LO FOR I -
BE ", "'" "" o"', "a",
I , NETBR SERIER WHIM DOE BAU. METER 1AUdE IS- HIGH DWN GUAL
WE a H."ZONTAL IN H..ZOWN- ourup, ED To OR. I.—SAI
MOOEL USE iikE AS AEA— AND ADD A SINGLE CHECK. EQUAL TO FORD VIENI—AW-11-41.
GO — SEAVss, IAIDII ad— 1 10— 111,
1" UNPAVED ARCAA: CANSION 1324 MS.' — SuCTLE INES. —a AND CAST IRM READER NOR:
N G PDOE: ARMOR CAST M001946PCX12 DICK W1 A&WILHESED9 AGE US
TO VACANT LIT (FUTURE USE) LOCATION MARKED WON PAINTED 2' X IV STAKE WITH 'WATER' STENCILED ON 9
14 C& VINYL COMES WLRE TRACER (TOED TO PI,LSTLC PIPE EVERY Is') To BE GRCUNDED AT METER AND HOUSE
SCHEDULE Q 3/4- OR V PUUG, REHM ISHIN CONNECTION IS MOE TO CUSTOMER ONE WM COMPRESSION I'MING,
WATER SON CE TO HOUSE, INSIAs.1ED BY OYMER/COETRAOTGR (PER PLUMBING CODE)
PROPERTY M ER RESPONSIBLE FOR PURCOUDING 3
DEPARILM Mr. CITY WILL SUPPLY ARD NETAUL METGD/�TEORR PU MOTOR THROUGH ME CITY AT DEVID,OPMUHT BERVIDER
PROVIDE REDJ US REDHASE; IF USING 3/4" MVER. CONTRACTOR YEALL
PACK SIDE OF METER BOX SHAU- BE SET AT ME PROPERTY ONE UNLESS APPROWD BY THE CITY ENGINEER.
DIED `I E— " 'D` EST BE -R— Asess -USES — RATED Bes Is APIAGNIG. BY CITY ENSINCERA.
ADEVISR). DATE
3/4"- jl.j�NUAIY .1.
T , S 'd,
ql.�EDM�DN S1 WA E�
I R ERViCE
Ty 0 1 ST L __ T ' STANDARD
PUBLIC WORKS INSTALLATION
DEPARTMENT DETAIL
WA-130
STANDARD DETAIL
A,
"IM'
..........
<��113 L
YIELD
ED I. Nes,
N,tA:S,,T.U1PE6H-2,.d6H-3
fOrthl, 111190fth, TSR
111"IdEr cDdBS used Id this figurs. T.
UEC.MEAE
... NAd. 7) 1, OUVR,
Sh.uldartap.,
6
A
(.PEI ... 1)
7 /-L
1ML
7 Yi,
QN3
LC
NOW: S, TECO,, SH-2 And! 6H.3 rNA),
"ERIA" nd., I.D.r t
Typical Application 3
MUTCD DETAIL Typical Application I I
SCALE: NTS
(EiB Im
GNGIIN�IEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
G1111119
PC CC
ED =) :3
MIT I.,
Z W_
t t
ED: cc
DESIGN: VD
DRAWN:
ATD
CHECK:
JOB NO:
18044.20
DATE:
08/21/18
(0
LLI 3t C-4
Q 0
z Lj 00
LLJ > 0)
LLJ Z
C14
r- V)
< 0
M C,4 Z
0
x L0 0
0 — LLI
ITEMUB
JAN 2 3 2019
(n
_j
Ld
_j
0
0
I WN
no
RETAINING WALL PLAN ", i 8., .
SCALE 1/811 = 1LO11 01 41 16,
5'-6" L 6'-10" L 5'-9" L 6LIf L
3/S2 4/S2
---------------- t ------- ------- - --- 277.00
1
--- -------- -------------- ---- 272.00
267.00
(�;:)WALL ELEVATION
\,�BGALF �1/8'
----- 277.00
272.00
267.00
('-B-'�WALL ELEVATION r-c"\WALL ELEVATION
��SCALE �1/811 = SCALE 1/811 - 11-011
277.00
- -'\WALL ELEVATION
D
SCALE 11811 = 11-011
272.00
267.00 26TOD 12LI111 L 267.00
----- ---------------- ---------------------------------------------- ----
.70
262.00 --- --- 262.00 262.00
257.00 ------ it:: 1- 257.00 --- 257.00
)0
PLANKEYNOTES
1. CAST IN PLACE CONCRETE RETAINING WALL. SEE WALL SECTIONS
& ELEVATIONS FOR WALL DIMENSION & REINr.
2. FTG STEP. SEE 7/S2
LEGEND
4) STEP rTG. SEE 7/S2
TOW TOP OF WALL
TOP TOP OF FOOTING
DIMENSIONS & ELEVATIONS
DIMENSIONS AND ELEVATIONS ON THIS PLAN ARE PROVIDED
FOR ESTIMATING PURPOSES ONLY. THE CONTRACTOR SHALL
BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND
ELEVATIONS WITH THE CURRENT PERMITTED SET OF CIVIL
DRAWINGS AND THE EXISTING GRADES IN THE FIELD AT THE
TIME OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE
REPORTED TO BOTH THE CIVIL AND STRUCTURAL ENGINEERS
IN WRITING PRIOR TO CONSTRUCTION OF THE WALL.
ow
, Ch
0, �*=-- ma.
a
0
0 E
C . 1 6
w
ho o Do
.Z.
4) 4m 0.-
r
o
rc-))
ILI*
Lu
Lu
;E
0
U)
U)
0
Lu
0
0
`\WALL ELEVATION
(�E)WALL ELEVATION t'-F:'�WALL ELEVATION (-G
,��SC5111 . I-011 \,�SCALE �1/811
ALE �118- -- \,�SCALE �1/811 = ll-�Dll
JAN 0 6
11ILDING 111-PAR-EN
.,,,o ...... I
S I OF 2-
S-19-083
+ 8" +
— �11'�
+811+
RET, WALL SECTION RET. WA L SECTION RET, WALL SECTION. RET. WALL SECTION
SCALE 1/211=11-011 SCALE 1/211=11-011 SCALE 1/211=11-011 SCALE 1/2'6110"
GENERAL CONSTRUCTION NOTES
CODE:
DESIGN AND CONSTRUCTION SMALL CONFORM TO THE PROVISIONS OF
THE 2015 IBC AS ADOPTED BY THE CITY OF EDMONDS, WASHINGTON.
DISCREPANCIES,
THE CONTRACTOR SHALL NOTIFY ENGINEER UPON FINDING ANY
DISCREPANCY OR OMISSION IN THE DRAWINGS OR SPECIFICATIONS.
SHORING & EXCAVATION:
THE CONTRACTOR SHALL BE SOLEY RESPONSIBLE FOR ALL EXCAVATION
PROCEDURES AND PROTECTION OF ADJACENT PROPERTY.
BACKPILL SOIL
WALL BACKrILL SHALL BE WELL GRADED FREE DRAINING MATERIAL.
BACKFILL SHALL BE PLACED IN ACCORDANCE WITH THE GEOTECHNICAL
RECOMMENDATIONS . ALL COMPACTION OCCURING WITHIN 51 OF THE
WALL SHALL BE COMPLETED USING HAND OPERATED MACHINERY.
DESIGN CRITERIA
FOUNDATION DESIGN:
RETAINING WALL DESIGN IS BASED ON THE FOLLOWING VALUES AS
PROVIDED IN THE GEOTECHNICAL REPORT BY GEOTECH CONSULTANTS
INC. DATED 01-25-18 & E-MAIL CORRESPONDENCE OF 09-27-19.
ALLOWABLE BEARING PRESSURE: 3,000 PSF
LATERAL EARTH PRESSURES: DRAINED BACKFILL
ACTIVE CONDITION: 35PCF EFW I LEVEL BACKFILL I
55PCF ErW I UPWARD SLOPE I
PASSIVE CONDITION: 30OPCP: EFW ULTIMATE
SEISMIC ADDITION: E = 8H PSF UNIFORM
SATURATED SOIL DENSITY-. 125 PCF w/ LEVEL BACKFILL
*5 PCF UPWARD SLOPED BACKrILL
COEFF Or FRICTION: 0.50 ULTIMATE
SPECIAL INSPECTION PLAN
GENERAL:
SPECIAL INSPECTION BY A QUALIFIED INSPECTOR IS REQUIRED IN
ACCORDANCE WITH THE 2015 IBC.
QUALIFICATION:
THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL
DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE BUILDING
OFFICIAL.
REQUIRED VERIFICATION & INSPECTION:
THE SPECIAL INSPECTOR SHALL PERFORM THE VERIFICATIONS &
INSPECTIONS NOTED IN THE SCHEDULE BELOW
INSPECTION & TESTING SCHEDULE
TYPES OF WORK —7r
REQ.
2015 IBC
I SECTION
CAST IN PLACE CONC.
REINFORCING STEEL, PLACEMENT,
P
11705.3
PLACEMENT OF CONCRETE
C
1706.3
VERIFYING USE OF REQUIRED DESIGN MIX
p
1705.3
TESTING OF THE CONCRETE FOR SPECIFIED
STRENGTH, AIR CONTENT AND SLUMP
C
1705.3
SOILS
VERIFICATION OF SOIL -BEARING CAPACITY:
INSTALLATION OF DRAINAGE SYSTEM:
C
1705.6
PLACEMENT & COMPACTION OF WALL
BACKFILL:
P 11705.6
FREQUENCY LEGEND
C = CONTINUOUS P = PERIODIC
SUBMITTAL OF REPORTS.
ALL SPECIAL INSPECTION REPORTS AND TESTING REPORTS SHALL BE
SUBMITTED TO THE OWNER, SITE STRUCTURES AND THE BUILDING
OFFICIAL BY THE AGENCY PERFORMING THE INSPECTION OR TESTING,
CONCRETE
CONCRETE REQUIREMEN�S_-.
LOCATION STRENGTH MAX W/C RATIO
WALLS & FTGS 550OPSI @ 28 DAYS 0.50
AIR CONTENT:
CONC.EXPOSED TO WEATHER SHALL CONTAIN 6% -/-1% ENTRAINED At —
MIX DESIGN:
SHALL BE BASED ON FIELD EXPERIENCE OR TRIAL MIXTURES IN
CONFORMANCE WITH THE SPECIFICATIONS.
MATERIAL REQUIREMENTS:
CEMENT: ASTM C150. ADMIXTURES: ACI 301.
AGGREGATES: ASTM C33. WATER: ASTM C94.
EXPOSURE CATEGORIES:
FREEZING THAWING Pi
SULFATE so
IN CONTACT W/ WATER wl
CORROSION PROTECTION cl
PLACING REQUIREMENTS:
PLACING:
PLACE CONCRETE AS NEARLY AS PRACTICABLE TO ITS FINAL POSITI�
TO AVOID SEGREGATION.
DEBRIS:
REMOVE ALL DEBRIS FROM FORMS PRIOR TO PLACING CONCRETE
CONSOLIDATION:
CONSOLIDATE CONCRETE BY SUITABLE MEANS. THOROUGHLY WOR
CONCRETE AROUND EMBEDDED ITEMS AND INTO CORNERS OF F%5.
L 10" L
RET, WALL SECTION
SCALE 1/2114-011
REINFORCING BAR
MATERIAL REQUIREMENT.
REINFORCING BARS:
USE DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60, EXCEPT
AS NOTED ON THE DRAWINGS,
FABRICATION AND PLACING REQUIREMENTS:
BENDING:
BARS SHALL BE BENT COLD, BARS PARTIALLY EMBEDDED IN CONCRETE
SHALL NOT BE FIELD BENT UNLESS NOTED OR SHOWN OTHERWISE OR
AUTHORIZED BY THE ENGINEER,
CONCRETE COVER-.
MINIMUM CONCRETE COVER FOR RtINF. SHALL BE AS FOLLOWS, UNLESS
NOTED OTHERWISE:
CONCRETE CAST AGAINST EARTH-311
CONCRETE! CAST AGAINST FORMS AND
EXPOSED TO EARTH- 1-1/211
WET SETTINGS.
REINFORCEMENT ANCHOR BOLTS, OR ANY EMBEDDED ITEM WITHIN THE
CONCRETE, MAY NOT BE SET INTO THE CONCRETE AFTER IT HAS BEEN
POURED WITHIN THE FORMS.
LAP SPLICES.
LAP ALL BARS 2411 MIN UNLESS SHOWN OTHERWISE ON THESE DWGS.
WALL SECTION
GENERAL KEYNOTES
1. APPLY PREFABRICATED DRAINAGE PANEL TO ALL WALLS. EXTEND
DRAINAGE PANEL TO WITHIN 1211 OF FINISHED GRADE. SEE
GEOTECHNICAL ENGINEER FOR MATERIAL SPECIFICATIONS,
2. 4`0 PERFORATED PVC FOOTING DRAIN AT ALL WALL SECTIONS,
WRAP IN 161W(ill MINIMUM DRAIN ROCK BEDDING & FILTER FABRIC.
ROUTE DRAIN TO DISCHARGE POINT AS SHOWN ON CIVIL DWGS.
3. LEAVE SURFACE BETWEEN WALL & FOOTING ROUGH,
4. FINISHED GRADE AT THE BACKFILL FACE OF THE WALL, HEIGHT
OF BACKFILL MAY EXTEND TO THE TOP OF THE WALL.
5. CONCRETE PAVING SECTION AT THE DOWNHILL FACE OF THE
WALL. PROVIDE 611 MIN COVER OVER THE TOP OF THE FTG.
WALL SECTION
REINFORCING KEYNOTES
100. 8" OR 1011 THICK CONCRETE RETAINING WALL. REINF W/ #5@12"olc
HORZ & 46@16"o/c VERT, PLACE VERT REINF NEAR THE BACKFILL
FACE OF THE WALL. PROVIDE 12145 CONTINUOUS HORZ BARS 0
THE TOP OF THE WALL
101. 8" THICK CONCRETE RETAINING WALL. REINF W/ #5@12"o/c HORZ &
#5@16"o/c VERT. PLACE VERT REINF NEAR THE BACKFILL FACE
OF THE WALL. PROVIDE 12145 CONTINUOUS HORZ BARS 0 THE
TOP OF THE WALL. EME, VERT BARS INTO FTG w/ STD HOOK @
3FT TALL WALL.
102. #6@16"o/c TRANSVERSE,
105. #5016"o/c TRANSVERSE.
104. #5 LONGITUDINAL TOP & BOT AS SHOWN. LAP 2411 MIN @ ALL
SPLICE LOCATIONS.
105. #6 WALL TO FOOTING DOWELS @ all o/c. PROVIDE STD HOOK @
END OF BAR CAST INTO FOOTING. DOWELS SHALL BE EMBEDDED
A MINIMUM OF 1111 INTO 14' THK FTG. SEP 6/S2 FOR PLACEMENT
REQUIREMENTS.
106. #6 WALL TO FOOTING DOWELS @ 1611 o/c. PROVIDE STD HOOK @
END OF BAR CAST INTO FOOTING. DOWELS SHALL BE EMBEDDED
A MINIMUM OF 9' -/- 1/211 INTO THE 121 FOOTING. SEE 6/52 FOR
PLACEMENT REQUIREMENTS.
107. #5 WALL TO FOOTING DOWELS @ 1611 o/c. PROVIDE STD HOOK @
END OF BAR CAST INTO FOOTING. DOWELS SHALL BE EMBEDDED
A MINIMUM OF 11" -/- 1/211 INTO THE 1411 FOOTING. SEE 6/S2 FOR
PLACEMENT REQUIREMENTS.
108, #5@16110/c
21
p
92
c
T
w
r
z
.8 ur K
w (a
(C-3)
DOWEL & VERT REINF TO BE PLACED IN
LINE DOWN THE LENGTH OF THE WALL
DOWEL w/o VFR,--/ PTA Tn Ul VERT WALL REINF
BAR SPLICE DOWEL
TYP FTG DOWEL PLACEMENT DETAIL
/-6�
SCALE 1"af-O'll
61-00 MIN 141-
TYP
< r 2
ui
MIN
F:TG CONT REINF
SEE PLAN
SPLICE BARS TO MATCH
FTG REINF JAN 0 6 7T. 1
;E
0
U)
cl)
0
2E
0
Lu
I&
0
SUILDIN
C OFEDMON05""
'A"Tm
0
TYPIC
7 AL STEPPED FTG DETAIL" OF 2
\,�SCALE 3/8114-0-1