Loading...
BLD2019-0078OV EbAf CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 PHONE: (425) 771-0220 - FA X: (425) 771-0221 STATUS: ISSUED 07/11/2019 Pem-dt#: BLD20190078 Expiration Date: 07/11/3010 Project Address: 18209 76TH AVIE W, EDMO-NDS Parcel No: 00370800300goo PROPERTY OWNER APPLICANT CONTRACTOR JAMES& ALISON POPE PINNACLE BUILDERS LLC PINNACLE BUILDERS LLC 18209 76TH AVE W CIO MITCHELL GAYNOR CIO MITCHELL GAYNOR EDMONDS, WA 98026 4654 ELSICA DR 4654 ELSICA DR CLINTON, WA 98236 CLINTON, WA 98236 (425) 350-7773 (425) 275-6566 (425) 275-6566 LICENSE #: pinnabl842mf EXP 07/06/2020 JOB DESCRIPTION ADD 1,489 SF TO EMSTING SINGLE FAMILY RESIDENCE AND INTERIOR REMODEL. PLUMBING AND MECHANICAL INCLUDED. VALUATION: $131,577 PERMIT TYPE Residential PERMIT GROUP: 02 - Addition GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: VB RETAINING WALL ROCKERY: OCCUPANT GROUP: SFR IRC OCCUPANT LOAD: FENCE: 0 X 0 FT.) CODE: 2015 IRC/`UPC/WSEC JOTHER: ------- OTHER DESC: I ZONE: RS-12 INUMBER OF STORIES: 2 IVESTED DATE� INUMBER OF DWELLING UNITS: I ILOT #: ENISTING ARE% BASEMENT. 0 1 ST FLOOR. 0 2ND FLOOR 0 PROPOSITI AREA BASEMENT - 0 IST FLOOR: 244 2ND FLOOR 733 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 13RD FLOOR: 0 GARAGE: 121 DECK: 391 OTHER: 0 BEDROOMS 0 BATHROOMS: 0 1BEDROOMS: 0 BATHROOMS1 FRONTSLTBACK SIDESETBACK RF-4,RSErBACK REQUIRED: 25' PROPOSED W=S8' 7 �rQUIRED: 10' PROPOSED N— 1 V-6" IREQUIRED: 25' PROPOSED: E= 43' HEIGHT ALLOWED:O PROPOSED:O IREQUIRED 10, PROPOSED: S-- 20--S" SETBACK NOTES: * Height to addition is 23'-1 1/4" I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. �AIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HISMER DEPJTY AND ALL FEES ARE PAID. ,7 7 ILI 7/11/19 IV Signature Print Nah:e /Date Released By Date ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL ORA CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109/ IBCI 10/ IRCI 10. F] FIRE = APPLICANT = ASSESSOR = CITY �-# -4 too 10, 111IN[L-1 4b MOON% L01) �01 IVA 4�,R STATUS: ISSUED BLD20190078 CONDITIONS I • Installer shall provide the manufacturer's installation, operating instructions, and a whole house ventilation system operation description. A label shall be affixed to the whole house timer control that reads " Whole House Ventilation" (see operating instructions). • Special inspections have been called for on this project and are noted on the approved construction plans and building permit. It is the owner and/or contractors responsibility to assure that reports are provided to the City on a weekly basis. Be advised -- if special inspection reports are not forthcoming, the Building Official may issue a "Stop Work" and no City inspections will be provided until such time as the reporting agency has complied and reports are reviewed and approved by the City. • Gas pipe test must be observed by City Building Inspector, affidavits shall not be accepted. • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check thejob card for all required City inspections including final project approval and final occupancy inspections. • Any request foraltemate design, modification, variance or other administrative deviation (hereinafter "variance") Rom adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and I 0:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating fi-om construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance ofthis pertnit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. Maintain erosion & sedimentation control per city standards. Call for required inspections as noted and prior to backfill. Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per City standards that is caused by or occurs during the permitted project. I INSPECTIONS THIS PERMIT AUTHORIZES ONLY THEWORK NOTED. THIS PERMITCOVERS WORKTO BEDONEON PRIVATEPROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19,00.005(A) (6) 7� TO SCHEDULE INSPECIqONS I BUILDING I JENGINEERING (425) 771-0220 EXT. 1326 A. Go to: www.edmondswa.gov 12. Then: Services 3. Then: Perm its/De\el opment 4. Then: Online Permit Info 5: If you don't have one already, create a login (upper right hand comer) 6: Schedule vouf inspection Building Department Inspections are now scheduled online. If you ha\e difficulties, please call the Building Department front desk for assistance during office hours. (425) 771-0220 FIRE (425) 775-7720 PUBLIC WORKS (425) 771-0235 RECYCLING (426) 275-4801 When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. _ * E-Erosion Control/Mobilization .r - -'I). • E-Engineering Final • B-Preconstruction meeting • B-Setbacks • B-Footings • B-Foundation Wall • B-Foundation Drainage • B-Isolated Footings/Piers • B-Special Inspection Epoxy Anchors • B-Plumb Rough In • B-Gas Test/Pipe • B-Mechanical Rough In • B-EAerior Wall Sheathing • B-Roof Sheathing • B-ShearNailing • B-Height Verification • B-Framing • B-Insulation/Energy • B-Building Final • B-Other I 0 September 5, 2019 Project#: 18-273 Pope Remodel 18209 761" Ave W Edmonds, WA Attn: Mitchell Gaynor Re: Pope Engineering Letter To Whom It May Concern: Iridium 635 West 5300 South, Ste 203 Salt Lake City, UT 84123 Ph: 801-974-5101 Fax: 801-974-5102 RECEIVED SEP 09 2019 DEVELOPMENT SERVICES COUNTER SCANNED BE? 0 % 101% The adjustments made to the front garage wall and back bathroom wall will not require any upsizing of the already defined structural elements. This includes, FB-1, FB-3, RB-2, and the 2x 10 joists. Thank you, Braden Jenkins Iridiurn AE If-4 ; 9088 iST ED HI CT C MAN SE 0 tWASHIET ko A- 18-273 N of ED SPECIAL INSPECTION AND TESTING AGREEMENT Permit #: Project: —Pope Addition BLD2019-0078 Prior to issuance qf a permit, thisform must be completed it? its entirety and returned to the Cityfor approval. The compleledfirm must have signatures of acknowledgment by allparties. DUTIES AND RESPONSIBILITIES Special Inspection Firm and Special Inspectors: The Special Inspection firm of - FS I / AI'C- will perform special inspection for the following types of work (separate forms must be submitted if more than one firm Is to be employed): —Reinforced Concrete —Bolting in Concrete Prestressed Concrete —Shotcrete —Structural Masonry Structural Steel/Welding —High Strength Bolting —Spray applied Fireproofing Smoke Control Systems _X_�Lateral Wood —Structural Observation by design professional .Grading/soils Steel Floor and Roof Decks ._X_Other—Epoxy Hold Down Installation All individual inspectors to be employed on this project will be WABO certified for the type of work they are to inspect. If inspection is for work that is not covered by the WABO categories, or the inspector is not WABO certified, a detailed resume of the inspector and firm must be submitted, The resume must show that the inspector and the firm are qualified by education and experience to perform the work and testing required by the project design and specifications. The work shall be inspected for conformance with the plans and specifications approved by the City. Revisions and addenda sheets will not be used for inspection, unless they have been approved by the City. Inspection records shali include: A daily record to be maintained on site, itemizing the inspections performed. Any nonconforming work shall be brought to the immediate attention of the contractor for resolution. A weekly report shall be submitted to the City; detailing the inspections and testing performed, listing any nonconforming work and resolution of nonconforming items, A final report shall be submitted to the building department prior to the Certificate of Occupancy being issued, This report will indicate that inspection and testing was completed in conformance with the M�' r,�_' E Milit M \XEDMSVR-DEP'rFS\Buildin&NHandouts information by Chuck\plan reviewkomments - Building Division reviewsW I 0-�Ail%p i ion Special Inspection Form (unsigned).docA/2019 APR 0 9 2019 BUILDING DEPARThriENT CITY OF EDMONPS 4 approved plans, specifications and approved revisions or addenda. Any unresolved discrepancies must be detailed in the final report. Contractor: The contractor shall provide the special inspector or agency adequate notification of work requiring inspection, The City approved plan and specifications must be made available, at the jobsite for the use of the special inspector and the City inspector. The contractor sMl maintain all daily inspection reports, on site, for review by all parties. The special inspection functions are considered to be in addition to the normal inspections performed by the City and the contractor is responsible for contacting the City to schedule regular inspections. No concrete shall be poured or other work covered until approval is given by the City inspector. Buildia Department: The building department shall review any revisions and addenda. The City inspector will monitor the special inspection functions for compliance with the agreement and the approved plans. The City inspector shall be responsible for approving various stages of construction to be covered and for work to proceed. Design Professionals: The architect andior engineer will clearly indicate on the plans and specifications the specific types of special inspection required and shall include a schedulefor inspection and testing. The architect and�'or engineer will coordinate their revision and addenda process in such a way as to ensure that all required City approvals are obtained, prior to work shown on the revisions being performed in the field. Owner: The project owner, or the architect or engineer acting as tile owners agent, shall employ the special inspector or agency. ENFORCEMENT A failure of the special inspector or firm to perform in keeping with the requirements of the IBC, the approved plans and this document, may void this agreement and the Building Official's approval of the special inspector. In such a case a new special inspector and/or firm would need to be proposed for approval. A failure of the design andlor construction parties to perform in accordance with this agreement may result in a STOP WORK notice being posted on the project until nonconforming items have been resolved. ACKNOWLEDGMENTS I have read and agree to comply with the terms and conditions of this agreement. Owner: J (2 !?I je� eO ,��__________jignature Contractor: Z Arch. Designer: Tiek Design Group _Signature Engineer : Iridium AE ______Signature Date Date: Date., 3/26/2019 Date: 3/26119 Special Insp. Psl� L-(- /F� vi:( A-1 1,-, F — - Signature_,,- Date: _ 3/- //,� Special Insp. Agency. ACCEPTED FOR THE CITY OF EDMONDS BUILDING DIVISION Date: A01-1 Building Division revie%vs�-)019-0079 Pope Addition By: _ U) 2d - T 2 —L ,1EDMS -DEP - %Build mW Handouts Information by Chuck' plan rev ieWcomments - Special Inspection Form, (unsigned) d-,c3,6 1-019 Permit # ov FI),,, v, FD) Uj I ��, Address: 18209 76th ave w, Edmonds APR 0 9 2019 Home Owner: Alison and James Pope BUIMING DEPARTMENT CITY OF EDMONDS Contractor: Pinnacle Builders LLC This form may be used to help establish the percentage of demolition work performed to an existing home in the course of a remodel. Once demolition has met or exceeded 75% of the value of the existing home's replacement cost, the structure will be required to be rebuilt to the standards of new construction. Replacement cost of existing home $_348,700 How was the value determined? Cost to Rebuild as Existing Component Value of Existing Component Percentage removed Replacement cost of removed component Notes Foundation 25 , 500 10% 2,550 Floor Framing 22,000 20% 4,400 Floor Insulation 5,200 20% 1,040 Wall Framing 32,000 55% 17,600 Wall Insulation 6,SOO 55% 3,575 Siding 23,000 100% 23,000 Roof Framing 27,000 65% 17,550 Attic Insulation 4,500 60% 2,700 Windows 15,000 60% 9,000 Doors 10,500 50% 5,250 Plumbing 21,000 60% 12,600 Electrical 23,500 50% 11,750 HVAC 16,500 10% 1,650 Drywall 21,000 60% 12,600 Cabinets 12,500 100% 12,500 Deck 8,000 100% 8,000 Other 75,000 35% 26,250 Total 348,700 172,015 % of total removed Percentage of Removed equals 'Total of Column 4 divided by Full Replacement cost' equals -49.33-% Owner Contractor Date -]-(D -Zot_7 Date &6atolclftl FliF, WATERSHED "COMPANY April 9, 2019 Alison Pope 18209 76th Avenue W Edmunds WA 98026 425-350-7773 Alison.pope@comcast.net Re: Wetland and Stream Reconnaissance Study The Watershed Company Reference Number: 190326 Dear Alison: SCIENCE & DESIGN KEW M-1 APR 0 9 2019 BUILDING DEPARTMENT CITY OF EDMONDS On April 1, 2019 Ecologist Roen Hohlfeld visited the property located at 18209 76th Avenue W. in the City of Edmunds to screen for jurisdictional wetlands and streams in the area identified by the City along the west side of 76th Avenue W. This letter summarizes the findings of the study. The following document is enclosed: 0 Site Sketch Methodology The study area was evaluated for wetlands using methodology from the Regional Supplement to the Corps of Engineers Wetland Delineation Manual: Western Mountains, Valleys, and Coast Region Version 2.0 (Regional Supplement) (US Army Corps of Engineers [Corps] May 2010). Identified wetlands were classified according to the 2014 Western Washington Wetland Rating System (Ecology Publication 14-06-029). Public -domain information on the subject properties was reviewed for this reconnaissance study and include the following: U.S. Fish and Wildlife Service National Wetland Inventory (NWI) maps Snohomish County PDS Map Portal Characterization of climatic conditions for precipitation was determined using the WETS table methodology from the USDA NRCS document Part 650 Engineering Field Handbook, National Engineering Handbook, Hydrology Tools for Wetland Identification and Analysis, Chapter 19 (September 2015). The Seattle -Tacoma International AP station as recorded by NOAA (http://agacis.rcc-acis.org/) was used as a source for precipitation 750 Sixth Street South Kirkland, WA 98033 p 425.822.5242 , f 425.827.8136 1 watershedco.com Wetland Reconnaissance Study Alison Pope April, 2019 Page 2 data. The WETS table methodology uses climate data from the three months prior to the site visit month to determine if normal conditions are present. Findings On April 1, 2019 Ecologist Roen Hohlfeld visited the property located at 18209 76th Avenue W. in the City of Edmunds to screen for jurisdictional wetlands and streams in the area identified by the City along the west side of 76th Avenue W. According to Snohomish County PDS Map Portal, the subject parcel is located within the City of Edmunds, and zoned single-family residential. Climactic conditions were considered normal on the day of the site visit. U.S. Fish and Wildlife Service National Wetland Inventory (NWI) maps illustrate a Riverine System (R4SBC) approximately 250 feet west of the subject parcel (figure 1). Nc additional stream or wetland features were mapped within proximity of the subject parcel by the National Wetland Inventory. As shown on the attached sketch, one stream (Stream A, Perrinville Creek) and two associated wetland areas (Wetland A and Wetland B) were identified within the study area. Figure 1. - National Wetlands Inventory (NWI) mapped streams and wetlands. Wetland Reconnaissance Study Alison Pope April, 2019 Page 3 Stream A flows north along the west side of 761h Avenue W. and enters a large culvert approximately 375 feet south of the subject parcel. Hydrophytic vegetation indicative of wetland conditions, such as red -osier dogwood, Pacific ninebark, and skunk cabbage, is present along the daylighted section of Stream A, south of the culvert. According to the City of Edmunds municipal code, the maximum regulated wetland buffer width is 300 feet, so this potential wetland area should not affect the subject parcel. To the north of this culvert, the topography and plant community is dominated by Douglas -fir and black locust trees, which are indicative of non -wetland areas. Further north along 7611, Ave W., the landscape consists of single-family homes with ornamental plantings and lawn. The topography slopes gently to the west and it does not appear that there are any wetland areas in the immediately vicinity of these homes. Since we did not have permission to enter privately owned property west of 7611, Avenue W., we could not determine the precise location of the Stream A culvert outlet or verify the accuracy of the mapped stream. However, based upon topography and NWI maps, it appears that Stream A is daylighted as it flows north, approximately 250 feet west of the subject parcel. Two small culvert outfalls are located approximately 150 and 200 feet north of the subject parcel. These culverts appear to be draining stormwater from residential developments; there are no obvious or mapped stream channels upstream and they do not appear to be fed by any natural source of hydrology. Therefore, it appears any flow from these culverts would not be regulated as stream channels. A second wetland area, Wetland B, appears to be associated with these stormwater features and Stream A. Plants indicative of wetland conditions, including watercress, salmonberry, and red alder are growing in this area and wetland hydrology was evident from the public right-of-way. Wetland B is estimated to rate as a Category 11 wetland with seven points for habitat. Per EMC 23.50.F.1 the City of Edmunds would require Wetland B to have a buffer width of 150 feet. It does not appear that this buffer would affect the subject parcel. Furthermore, EMC 23.40.220.C.4 provides a provision for development proposals located within interrupted stream or wetland buffers. In this case, the buffer appears to be interrupted by 76d, Avenue W. This physical barrier effectively separates the subject parcel from Wetland B. Any portions of the buffer area that may be located east of this street appear to be functionally isolated from Wetland B, based upon field observations of hydrology, geology, and habitat connection potential, as well as the permanence of the barrier. Wetland Reconnaissance Study Alison Pope April, 2019 Page 4 Disclaimer Please note: The information contained in this email is based on the application of technical guidelines currently accepted as the best available science and in conjunction with the manuals and criteria outlined in the methods section. All discussions, conclusions and recommendations reflect the best professional judgment of the author(s) and are based upon information available to us at the time the study was conducted. All work was completed in good faith, within the constraints of budget, scope, and timing. The findings of this report are subject to verification and agreement by the appropriate local, State and Federal regulatory authorities. No warranty, expressed or implied, is made. Should you have any questions or concerns regarding our findings, please feel free to contact me. Sincerely, 11� Roen Hohlfeld Landscape Designer / Ecologist / Arborist Enclosures Stream A V.-A Creek) N, ............ t " yo, it t 0 < Op 76thAvenueW , so -- IX I 7 BUILDING PERMIT APPLICATION P,,it Develo pmentServices Building Division 121 Sth Ave N / Edmonds, WA 98020 'Oe. I g4- 425.771.0220 For handouts, submittal requirements, permit status and inspection scheduling information go to: http://www.edmondswa.fzov/ JOB SITE INFORMATION/LOCATION: (Where the work is taking place) Job Site Address: -7 V6_ Vul Parcel: Lot /Unit/Suite #: Subdivision: PROPERTY OWNER: N a m e: d us a ^) '�q�> I -Am is P0 jw- MailingAddress: 1829el' :761W 19VC W City/State/Zip: ft� 14 Q A/ b S UOq- Id 0 2-4, Phone #: YZ 57 - -3 5_2 - -7:7 7 S Email: 03-Cor^c-0&4-, lj�e� OWNER INSTALLATION: *If yes, read and sign* Will work be performed by the property owner? 0 Yes I own, reside in, or will reside in the completed structdoe. This installation is being made on property that I own which is not intended for sale, lease, rent, or exchange according to RCW 18.27.090. Owner Signature: APPLICANT/ CONTACT INFORMATION: Name of Applicant: �Nntm& P1A11V19<_L-t' 45 %)W-D'qA4 L4-(— MailingAddress: 'IL5-q 4-4_>11/9 Z>/Z City/State/Zip: AJ" 0 W,q 'i QVZ 9,6 Phoneft: L/-ZS-- 27T -G51 (o E-mail: , /. con--% GENERAL CONTRACTOR: (if different from applicant) General Contractor: Mailing Address: -0/' City/State/Zip: A, Phone #: E-mail: WA STATE CONTRACTOR L & I # (CCB) & EXPIRATION DATE: r/ /V/V R-61, 'b '1112— /)IF CITY OF EDMONDS BUSINESS LICENSE #: a 0 110 1 1'_1 TYPE OF PERMIT (Provide El Accessory Structure/ Detached Garage Details on Page 2) )&d clition • Demolition *M echanical • New Single Family / Duplex "�'�nlumbing Y�I\r • Fire Sprinkler XRemodel 11 New Commercial/ Mixed Use e-Roof 0 Signs 0 Tank 0 Tenant Improvement 0 Other Remodel Permff fees are based on: The value of the work performed. Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the work indicated on this application. Valuation: PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION Basement sq ft: Finished EI Unfinished El Ist Floor, sq ft: gil 2nd Floor, sqft: -7'-3 Garage/Carport:, sq ft: Deck/Covered Porch/Patio: Other q ft: PROJECT DESCRIPTION #Pyn� ai —0 g--�( rA0Pjg]V ID jpjg L LO f 9-4—/710b e—L 14 ,4 I certify that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: Signature: Date GENERAL COMMERCIAL DATA Occupancy Group(s): Occupant Load(s): Type(s) of Construction: Fire Sprinklers: Yes C3 N o'V— WA STATE ENERGY CODE: If your project affects the building envelope, mechanical systems, and/or lighting, you must complete the appropriate WSEC forms. DEFERRED SUBMITTALS: All commercial building permits that will require associated plumbing, mechanical, fire sprinkler, and/or fire alarm permits are applied for separately. TI / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet MECHANICAL EQUIPMENT COUNTS (New and Relocated) BTUs Gas / Elec / Other QtY A/C Unit /Compressor Air Handler /VAV Boiler Dryer Duct Exhaust Fans CT- < ix, L— Fireplace Furnace Heat Pump Unit Hydronic Heating Roof Top Unit (Provide eleva- tions if a Commercial Bldg) Other: PLUMBING FIXTURE COUNTS (New, Relocated or re -piped) Qty QtY Clothes Washer Tub/ Showers Dishwasher Backflow Device (RPBA, DCDA, AVB) Drinking Fountain Pressure Reduction/ Regulator Valve Floor Drain/Sink Refrigerator Water Supply Hose Bibs Water Heater - Tankless I Or N Hydronic Heat Water Service Line Sinks Other: �C_ V Toilets Other: GAS/FUEL CONNECTION COUNTS (New, Relocated or re -piped) BTUs Qty BTUs Qty A/C Unit Outdoor BBQ/ Fire pit Boiler Stove/Range/Oven Dryer k� Water Heater Fireplace/ Insert Other: Furnace Other: MEDICAL GAS, AIR VACUUM COUNTS (New, Relocated or re -piped) Qty QtY Carbon Dioxide Nitrous Oxide Helium Oxygen Medical Air Other: Medical - Surgica Vacuum Other: DEMOLITION Type of structure to be demolished: Square footage of structure to be demolished: AHERA Survey done? Y/N PSCAA Case #: Critical Areas Determination: Study Required 11 Conditional Waiver El Waiver El i66iii6iikii Fill in Place El Fill Material: Removal 11 Size of Tank (Gallons) Critical Areas Determination: Study Required El Conditional Waiver El Waiver El GRADE/FILL/EXCAVATE Grading: Cut cubic yards Fill cubic yards Cut/ Fill in Critical Area: YesEl NOX GENERAL PROVISIONS APPLICATIONS: Applications are valid for a maximum of 1 year. ESLHA Applications, 2 years. LICENSING: All contractors and subcontractors are required to be licensed with Washington State Department of Labor & Industries and have a current City of Edmonds Business License. of EVAJO "VC. I S,),) CONTRACTOR INFORMATION: SIDE SEWER IR PERMIT APPLICATION APR 0 9 2019 BUILDING DEPARTMENT CITY OF EDMONDS Company Name: Site Contact: -Y tvc f0WAJAtl--4 &JJL,>��S tL& fl ),o Company Address: qt,�f &ZS1 c�,4 bV. Phone #: q-z 5- - -Z -7 r - (0 . �-z & city: VA Zip: qa,2,3 State License # r1lytj A '3 t-,a Li �2- M Expiration Date: -7 /o 6 / -zl- Z10 PROPERTY INFORMATION: Email #: City Business License# Alp -2 Z, 1-1 q Address: t 00 -74 *)l Owner's Name: Y4-y,�-/b U-7,:�,fnf--5 to0pr Phone #: q -Z -3 S-0 '7 -7 -7 -3 El FULL LINE REPLACEMENT [I SPOT REPAIR M PIPE BURST RELINE (PERMALINE ONLY) DESCRIPTION OF PROPOSED WORK (Be Specific): OCkIlk- F4,0fYN 3 " 77b 11 771- /A/-rO '*-X Q -P Al 6- 7.,V!�L ISSUANCE OF THIS PERMIT DOES NOT CONSTITUTE PERMISSION TO WORK ON ANY PROPERTY OTHER THAN T14AT OWNED BY THE SUBJECT PROPERTY OWNER. CERTIFICATIONS NECESSARY FOR INSTALLATION METHODS ARE TEE RESPONSIBILITY OF THE CONTRACTOR PERFORMING SAID WORK. I REPRESENT AND WARI ADJACENT PROPERTY, I PROPERTY. z SIGNATURE �O THE CITY OF EDMONDS, IF REPAIR OF EXISTING SEWER EXTENDS TO AN OWNERS EXPRESS PERMISSION TO PERFORM WORK ON THAT ADJACENT DATE '3 L-2 4, 9 Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds Critical Area Notice of Decision <-3 - - � - ^ I - -.I I I -A - ,r% I I f, Applicant: a% *- Z-2s I-' � E)PNr-sof — Property Owner: 150mts Critical Area File ZRIZ 0 19 00 k'\ Permit Number: 'Q:A-M0[96Q�3 Site Location: Av,�P-w. Parcel Number: ODIRO'90072005 ov Project Description: A-OUI f� 0o R'Conditional Waiver. No critical area report is required for the project described above. There will be no alteration of a Critical Area or its required buffer. 2. v-,' The proposal is an allowed activity pursuant to ECDC 23.40.220, 23.50.020, and/or 23.80.040. ---Cn+,trru&-j4- -&� Pvr5UaM- -h G-Cp"- 3. The proposal is exempt pursuant to ECDC 23.40.230. q . Erosion Hazard. Project is within erosion hazard area. Applicant must prepare an erosion and sediment control plan in compliance with ECDC 18.30. Critical Area Report Required. The proposed project is within a critical area and/or a critical area buffer and a critical area report is required. A critical area report has been submitted and evaluated for compliance with the following criteria pursuant to ECDC 23.40.160: I The proposal minimizes the impact on critical areas in accordance with ECDC 23.40.120, Mitigation sequencing; 2. The proposal does not pose an unreasonable threat to the public health, safety, or welfare on or off the development proposal site; 3. The proposal is consistent with the general purposes of this title and the public interest; 4. Any alterations permitted to the critical area are mitigated in accordance with ECDC 23.40.110, Mitigation requirements. 5. The proposal protects the critical area functions and values consistent with the best available science and results in no net loss of critical functions and values; and 6. The proposal is consistent with other applicable regulations and standards. Unfavorable Critical Area Decision. The proposed project is not exempt or does not adequately mitigate its impacts on critical areas and/or does not comply with the criteria in ECDC 23.40.160 and the provisions of the City of Edmonds critical area regulations. See attached findings of noncompliance. ff"Favorable Critical Area Decision. The proposed project as described above and as shown on the attached site plan meets or is exempt from the criteria in ECDC 23.40.160, Review Criteria, and complies with the applicable provisions of the City of Edmonds critical area regulations. Any subsequent changes to the proposal shall void this decision pending re -review of the proposal. Conditions. Critical Area specific condition(s) have been applied to the permit number referenced above. See referenced permit number for specific condition(s). F-I Notice on Title. Critical area notice on title recorded under AIN no it, IN-91k qtl Reviewer -- / Z-6�z Signature 41' Date Appeals: Any decision to approve, condition, or deny a development proposal or other activity based on the requirements of critical area regulations may be appealed according to, and as part of, the appeal procedure, if any, for the permit or approval involved. Revised 1112912016 Prescriptive Energy Code Compliance for All Climate Zones in Washington �rLOO Informat on Contact Information ALISON & JAMES POPE N9rCBELL GAYNOR 18209 76TH AVE W. PINNACLEBUUDERSWA@GMAILCOM EDMONDS, WA 98026 425-275-6566 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative COLBYDALLEY All Climate Zones R-Value' U-Factora Fenestration U-Factor b n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGCb,e n/a n/a Ceilingk 49" 0.026 Wood Frame Wa llg,m,n 21 int 0.056 Mass Wall R-Value' 21/2 1 h 0.056 Floor 309 0.029 Below Grade Wall" 10/15/21 int + TB 0.042 Slab d R-Value & Depth 10, 2 ft n1a *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Date 1-14-19 RECEISIN111mr% vitu JAN 2 3 2019 BUILDING CEUV COPY Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: Small Dwelling Unit: 1.5 credits Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. E12. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. F-13. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. 4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) la JEfficient Building Envelope la 0.5 1b Efficient Building Envelope lb 1.0 Ic Efficient Building Envelope 1c 2.0 Id Efficient Building Envelope ld 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC5d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 5d -6 Efficient Water Heating 5d 0.5 Renewable Electric Energy 0.5 Total Credits *Please refer to Table R406.2 for complete option descriptions F� El F� F1 F1 El F-1 El X El El 11 El X El 7 *1200 kwh 0.0 2.0 Fo,, 51: 1 foot.= 304.8 mm, ci .= continuous insulation, int.= intermediate framing a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the ins ulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. c "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Reserved. g Reserved. h Reserved. i The second R-value applies when more than half the insulation is on the interior of the mass wall. J Reserved. k For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38. I Reserved. m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. 4 Iridium IRIDIUM REP: ALG DATE: 10/25/2018 PROJECT#: 18-273 CLIENT: TIEK DESIGN P: (901) 974-5101 F: (801) 974-5102 A: 635 W 5300 S STE 203 MURRAY, UT 84123 DESIGN ClUTEMA 1 GOVERNING CODE: 2 ROOF LOADING 2.1 ROOF DEAD LOAD 2.2 ROOF LIVE LOAD 2.3 ROOF SNOW LOAD GROUND SNOW LOAD, Pg FLAT ROOF SNOW LOAD, Pf SNOW EXPOSURE FACTOR, C. THERMAL FACTOR, C, IMPORTANCE FACTOR, I 3 FLOOR LOADING 3.1 FLOOR DEAD LOAD 3.2 FLOOR LIVE LOAD 4 DECK LOADING 4.1 DECK DEAD LOAD 4.2 DECK LIVE LOAD 5 WALL WEIGHTS 5.1 EXTERIOR WALL DEAD LOAD 6 SEISMIC PARAMETERS 6.1 SEISMIC RISK CATEGORY 6.2 SEISMIC DESIGN CATEGORY 6.3 IMPORTANCE FACTOR, I 6.4 SNOW USED AS SEISMIC WT., Ws 6.5 ANALYSIS PROCEDURE USED 6.6 SPECTRAL RESPONSE ACCELERATIONS SHORT PERIOD, S, ONE -SEC PERIOD, S, SHORT PERIOD SITE COEF., F. LONG PERIOD SITE COEF., F, SHORT PERIOD ACCEL., SDS ONE SEC PERIOD ACCEL., SDI 6.7 SEISMIC FORCE RESISTING SYSTEM RESPONSE MOD. COEF., R DEFLECTION AMP. FACTOR, Cd OVERSTRENGTH FACTOR, no DESIGN BASE SHEAR, V 7 WIND PARAMETERS 7.1 ULTIMATE DESIGN WIND SPEED, V,, 7.2 WIND RISK CATEGORY 7.3 WIND EXPOSURE 7.4 INTERNAL PRESSURE COEFFICIENT 7.5 COMPONENTS& CLADDING PRESSURE PROJECT NAME: POPE REMODEL PROJECT LOCATION: 18209 76TH AVE EDMONDS, WA 2015 IBC 15 PSF 20 PSF CIFN cc?y 25 PSF 25 PSF 1.0 1.0 1.0 12 PSF 40 PSF APR 0 9 10 PSF BUILDING MEPARTMENT CITY OF EDMONDS 60 PSF 17 PSF D! THIS SHEET MUST BE WET STAMPED, 1.0 INITLkLED AND DATED TO BE VALID FOR OBTAINING A BUILDING PERMIT. REGISTERING 0.0 PSF (REUSE) OF THESE CALCULATIONS, DESIGN OR EQUIV. LATERAL FORCE ASSOCIATED PLANS IS PROHIBITED. 1.291 0.506 1.00 1.50 sm 0.861 R S RED TECT 0.506 LIGHT -FRAME (WOOD) ISTA UL VYWVASHINGTON 6.5 E 4.0 3.0 STRUCTURAL ONLY 0. 132 *W (FROM ASCE 12.8-2) 110 NTH Il THIS ENGINEERING CALCULATION PACKET C AND STAMP VALID FOR 180 DAYS FROM THE 0.18 DATE ON TEE STAND. AFTER THIS 180 DAY 16 PSF PERIOD, ADDITIONAL REVIEW AND NEWLY SIGNED WET STAMP WILL BE REQUIRED. 8 SOILS CRITERIA 8.1 SOIL BEARING PRESSURE 1,500 PSF 8.2 SOIL SITE CLASS D 8.3 FROST DEPTH 30 INCHES 8.4 GEOTECH STUDY USED NO COPYRIGHT IRIDIUM, LLC 2018 THIS ENGINEERING PACKET IS VALID FOR A SINGLE STRUCTURE AT THE LOCATION NOTED ABOVE PROJECT NUMBER 18-273 W& 0 T �rg U S GS Design Maps Summary Report im View Detailed Repgrt Er User —Specified Input �j nt Building Code Reference Document ASCE 7-10 Standard (which I.JSGS hazatcl data available In 2A-108) Site Coordinates 47.830N, 122340W Site Soil Classification Site Class D — "Stiff Soil" Risk Category I/II/III ............ . .. ... . .... . ... _W .. . . .. ........... h Y PO fi"E 96d 41 'Ediiionds* Terract- Mo So. re in . . ......... ........................ ....... . .. . . ... ..... .. ......... . z":4 ,Apo 4 USGS-Provided Output SS = 1.291 g S", = 1.291 g SOS = 0.861 g Si = 0.506 g S,, = 0.759 g S,,_ = 0. 506 g For information on how the SS and S1 values above have been calculated from probabilistic (rlsk-tatgeted) and deterministic ground motions in the direction of maximurn horizDntal response, please return to the application and select the "2009 NEHRP" building code reference document. NICE, Rcsponse Sptvtrum 114'A (049 041A UAW 44� IS., 140 POW, T (sml �AOI I", 'AAA Pesign Respon-wSpectrum PaW, T ism� STRUCTURAL MEMBERS DESIGN VALUES Fb (PSI) F, (PSI) F, -L (PSI) E (PSI) SELECTSTRUCTURAL 1,350 180 625 1.90E+06 SI`F#1 900 125 425 1.30E+06 DF#1 & BTR 1,150 180 625 1.80E+06 DF#2 850 180 625 1.60E+06 DF#2 ROUND 850 180 625 1.60E+06 HF#2 850 150 405 1.30E+06 LVL (1.9E) 2,600 285 750 1.90E+06 PSL (2.OE) 2,900 290 750 2.00E+06 GLB 2,400 265 650 1.80E+06 ASTM A-992 STEEL 33,000 20,000 N/A 2.90E+07 DEAD LUADS ROOF SHINGLES 6,00 PSF SHEATHING (7/16") 1.70 PSF INSULATION (I X 12) 1.20 PSF JOISTS, TRUSSES & BEAMS 3.00 PSF SHT' ROCK (5/8") 2.75 PSF MISC 0.00 PSF TOTAL 14.65 PSF USE 1 15 PS FLOOR HARDWOOD/CARPET 4.00 PSF SHEATHING (3/4") 2.20 PSF JOISTS & BEAMS 3.00 PSF SHT ROCK (5/8") 2.75 PSF Nusc 0.00 PSF TOTAL 11.95 PSF USE 12 PS DEC 1-1/2"SOFrWOOD DECKING 4.60 PSF JOISTS & BEAMS 5.00 PSF MISC O�00 PSF TOTAL 9.60 PSF USE 1 10 Ps EXTERIOR WALLS MIT ROCK (5/8") 2.75 PSF INSULATION (. 1 X 5.5) 0.55 PSF STUDS 1.70 PSF SHEATHING (7/16") 1.40 PSF SIDING OR STUCCO 10.00 PSF TOTAL 16.40 PSF USE 17 P� FLOORBEAMS SIMPLE SPAN BEAM LOCATION: DECK DESIGN LOADS FB- 7 FLAT ROOF SNOW LOAD TL 40 PSF DURATION INCREASE= 1,00 LL 25 PSF BEAM SPAN (FT) = 15.5 FLOOR LOAD TL 52 PSF VENEER(Y/N): NO LL 40 PSF TRIBUTARY LOADING DECK LOAD TL 70 PSF SPAN (FT) CANT. (FT) WTL (PLF WLL (PLF) LL 60 PSF ROOF 0.0 0.0 0 0 OTHERLOAD TL 125 PSF FLOOR 0.0 0.0 0 0 LL 50 PSF FLOOR 0.0 0.0 0 0 DECK 6.0 0.0 210 180 OTHER 0.0 0.0 TOTAL 210 180 POINTLOAD FROM TL= 0 LL= 0 LOCATION (a) = 7.8 b=L-a= 7.8 EQUIV. UNIFORM TL = 0 EQUIV. UNWORM LL = 0 REACTIONS LIGHT SIDE (TL) = 1628 LBS LBS (LL) = 1395 LBS LBS (DL) = 233 LBS FT HEAVY SIDE (TL) = 1629 LBS FT (a>b) (LL) = 1395 L13S PLF (DL) = 233 LBS PLF Rrt/wTL = 7.8 FT BEAM SUPPORT LIGHT SIDE: 2 HEIGHT (FT): 8 SPOT FOOTING: N HEAVY SIDE: 2 HEIGHT (FT): 8 SPOT FOOTING: N STRUCTURAL COMPOSITE LUMBER TYPE:GLB DEPTH (d)est. = 9 IN. WIDTH (b)est. = 5 1/8 IN. X!= 7.8 FT MAX SUPPORT LOAD STUDS 3900 LBS Fr. SQR STUDS 3800 LBS Fr. SQR Fb = 2,400 PSI Fv = 265 PSI E = 1.80E:.06 PSI CF = 1.00 A = 46.13 IN(2) S = 69,19 IIN(3) I = 311,34 IN(4) FB -7 USE 15-1/8" X 9" GLB SAFETY FACTOR 1.24 MAXIMUM MOMENT MmAx = 6,307 FT-LBS 6 CRITERIA: TL ": U LL 8MAx: u ili- 8MAX@ 7.9 FT. (FROM LIGHT SIDE) TLSmAx= 0.49 IN. L/ 392 LL6,m= 0.42 IN. IJ 44� AREQ. = 8.32 IN(2) SREQ. = 31.53 IN(3) IREQ(TL) = 195.50 IN(4) ImQ(I-L) = 251.36 IN(4) BRG REQ- = 3 IN. SIMTLE SPAN BEAM LOCATION: DECK DESIGN LOADS FB- 6 FLAT ROOF SNOW LOAD TL 40 PSF DURATION INCREASE= ikl') LL 25 PSF BEAM SPAN (Fr) = 13.5 FLOORLOAD TL 52 PSF VENEER (Y/N): NO LL 40 PSF TRIBUTARY LOADING DECK LOAD TL 70 PSF SPAN Cff) CANT. (FT) WTL (PLF WLL (PLF) LL 60 PSF ROOF 0.0 0.0 0 0 OTHERLOAD TL 125 PSF FLOOR 0.0 0.0 0 0 LL 50 PSF FLOOR 0.0 0.0 0 0 DECK 9.0 0.0 315 270 OTHER 0.0 0.0 TOTAL 315 270 POINT LOAD REACTIONS MAXIMUM MOMENT FROM LIGHT SIDE (TL) = 2126 LBS M. 7,176 FT-LBS TL= 0 LBS (LL) � L823 LBS LL= 0 LBS (DL) = 304 LBS 6 CRITERIA: LOCATION (a) = 6.8 FT HEAVY SIDE (TL) = 2126 LBS TL &.: L/ b=L-a= 6.8 FT (a> b) (LL) = 1823 LBS LLS.: U EQUIV. UNIFORM TL = 0 PLF (DL) = 304 LBS EQUIV. UNIFORM LL = 0 PLF RrL/wTL = 6.8 FT X'= 6,8 FT BEAM SUPPORT MAX SUPPORT LOAD LIGHT SIDE: 2 STUDS 3800 LBS HEIGHT (FT): 8 SPOT FOOTING: N Fr. SQR HEAVY SIDE: 2 STUDS 3800 LBS HEIGHT (FT): 8 SPOT FOOTING: N FT. SQR STRUCTURAL COMPOSITE LUM13ER TYPE:GLB DEPTH (d)est. = 9 IN. Fb = 2,400 PSI 8m"@ 6.8 Fr. (FROM LIGHT SD)E) WIDTH (b)est. = 5 1/8 IN. Fv = 265 PSI TL SmAx = 0.42 IN. LJ 386 E = 1-80FA-06 PSI LL SMAX = 0.36 IN- U ­ (LSL-1 CF = 1.00 A = 46.13 IN(2) AEQ. = 10.70 IN(2) S = 69,19 IN(3) S,,q. = 35.88 rN(3) I= 311.34 INt(4) IREQ(TL) = t93.75 IN(4) IREQ(LL) = 249.11 IN(4) BRGREQ. = 3 IN. FB -6 USE 15-1/8" X 9" GLB SAFETY FACTOR 1.25 SIMPLE SPAN BEAM LOCATION: GARAGE DESIGN LOADS FB - 5 FLAT ROOF SNOW LOAD TL 40 PSF DURATION INCREASE= 1.00, LL 25 PSF BEAM SPAN (FT) = 20.0 FLOORLOAD TL 52 PSF VENEER (Y/N): NO LL 40 PSF TRIBUTARY LOADING DECKLOAD TL 70 PSF SPAN (FT) CANT. (FT) WTL (PLF WLL (PLF) LL 60 PSF ROOF 8.0 2.0 250 156 OTHERLOAD TL 125 PSF FLOOR 17.0 0.0 442 340 LL 50 PSF FLOOR 0.0 0.0 0 0 DECK 0.0 0.0 0 0 OTHER 0.0 0,0 TOTAL 692 496 POINT LOAD REACTIONS MAXIMUM MOMENT FROM LIGHT SIDE (TL) = 6920 LBS MmAx = 34,600 FT-LBS TL= 0 LBS (LL) � 4963 LBS LL= 0 LBS (DL) = 1958 LBS 8 CRITERIA: LOCATION (a) = 10.0 FT HEAVY SIDE (TQ = 6920 LBS TL5,.: Ll b=L,a= 10.0 FT (a> b) (LL) = 4963 LBS LL 6.: Ij 4� EQU[V. UNIFORM TL = 0 PLF (DL) = 1958 LBS EQUfV. UNIFORM LL = 0 PLF RrtlwTL = 10.0 FT Xl= 10.0 FT BEAM SUPPORT MAX SUPPORT LOAD LIGHT SIDE: 4 ,X4 STUDS 8740 LBS HEIGHT (Fr): 9 SPOT FOOTING: Y 2.17 Fr. SQR HEAVY SIDE: 4 ,-X4 STUDS 8?40 LBS HEIGHT (FT): 9 SPOT FOOTING: Y 2.17 Fr. SQR STRUCTURAL COMPOSITE LUMBER TYPE: LVL (1.9E) DEPTH (d)est. = 18 IN. Fb = 2,600 PSI 8�x@ 10.0 FT. (FROM LIGHT SIDE) WIDTH (b)est. = 13/4 IN. Fv = 285 PSI TLSmAx= 0,51 IN. IJ 467 #OF MEMBERS = 3 E = 1.90F+06 PSI LLk"x= 0.37 IN. 1-/ 651 CF = 0.95 A = 94.50 IN(2) AREQ. = 30.96 IN(2) S= 283.50 [N(3) SREQ. = 168.75 IN(3) I= 2551.50 fN(4) IREQ(TL) = 1311.16 IN(4) I,,,(LL) = 1410.39 K4) BRGE, = 3 IN. FB -5 USE 1(3) 1-3/4" X 18" LVL(S) SAFETY FACTOR 1.68 STEEL BEAM 8MAX @ 10.0 Fr. (FROM LIGHT SIDE) DEPTH = 10.30 IN. Fb = 33,000 PSI TL 6,," = 0.60 11--T LJ 402 WIDTH = 5.77 IN. Fv = 20,000 PSI LL 5MAX = 0.43 IllE IJ 561 E = 2.90E+07 PSI A = 7.61 IN(2) ARFq. = 0.52 R-,�2) S = 27.90 IN(3) SpxQ. = 12.58 Il-�(3) I = 144.00 IN(4) 1p,,(rL) = 85�90 IN(4) 1,,Q(LL) = 92AI IN(4) FB -5 OR IWIOX26 SAFETY FACTOR 1.56 SIMPLE SPAN BEAM LOCATION: KITCHEN FB - 4 DURATION INCREASE= 1,00 BEAM SPAN (FT) = 22.0 VENEER(Y/N): NO TRIBUTARY LOADING SPAN (FT) CANT. (FT) Wn (PLF WLL (PLF) ROOF 0.0 0.0 0 0 FLOOR 20.0 0.0 520 400 FLOOR 0.0 0.0 0 0 DECK 0.0 0.0 0 0 OTHER 0.0 0.0 ii TOTAL 520 400 POINT LOAD REACTIONS FROM LIGHT SIDE (TL) = 5720 LBS TL= 0 LBS (LL) = 4400 LBS LL= 0 LBS (DL) = 1320 LBS LOCATION (a) = 11.0 FT HEAVY SIDE (TL) = 5720 LBS b=L,a= Il'o FT (a>b) (LL) = 4400 LBS EQUIV. UNIFORM TL = 0 PLF (DL) = 1320 LBS EQUIV. UNIFORM LL � 0 PLF Rrt/wTL = 11.0 FT BEAM SUPPORT LIGHT SIDE: 3 HEIGHT (Fr): 9 SPOT FOOTING; Y HEAVY SIDE: 3 HEIGHT (FT): 9 SPOT FOOTING: Y STRUCTURAL COMPOSITE LUM13ER TYPE: LVL (1.9E) DEPTH (d)est. = 18 IN. WIDTH (b)est. = 13/4 IN. #OF MEMBERS = 3 X!= 11.0 FT MAX SUPPORT LOAD STUDS 5990 LBS 1.98 Fr. SQR STUDS 5990 LBS 1.98 Fr. SQR Fb = 2,600 PSI Fv = 285 PSI E = 1.9013��6 PSI CF = 0.95 A = 94.50 IN(2) S = 283.50 IN(3) I = 2551,50 1N,(4) DESIGN LOADS FLAT ROOF SNOW LOAD TL 40 PSF LL 25 PSF FLOOR LOAD TL 52 PSF LL 40 PSF DECICLOAD TL 70 PSF LL 60 PSF OTHERLOAD TL 125 PSF LL 50 PSF MAXIMUM MOMENT MmAx = 31,460 FT-LBS 8 CRITERIA: TL 5.: L/.�, LL 6�.: L/ ,.13 8KAX @ 11.0 FT. (FROM LIGHT SIDE) TL SmAx = 0.57 IN. IJ 467 LL SMAX = 0.43 IN. Ll 607 AmQ. = 26.00 IN(2) SmQ. = 153.43 W,3) 1,EO(TL) = 1311.39 IN(4) IREQ(LL) = 1513.14 IN(4) BRG,,, = 3 IN FB 4 USE 1(3) 1-3/4" X 18" LVL(S) SAFETY FACTOR 1.69 STEEL BEAM 8KIAX@ I LO FT. (FROM LIGHT SIDE) DEPTH = 10.30 IN. Fb = 33,000 PSI TL 8mm = 0.66 IM Ll 402 VADTH = 5.77 IN. Fv = 20,000 PSI LLkm= 0.50 IN. LJ 523 E = 2.90E+07 PSI A = 7.61 IN(2) AREQ. = 0.43 IN(2) S = 27.90 IN(3) SREQ- = 11.44 IN(3) I = 144.00 IN(4) IREQ(TL) = 85�92 IN(4) IREQ(LL) = 99.14 IN(4) FB -4 OR lWlOX26 SAFETY FACTOR 1.45 SIWLE SPAN BEAM LOCATION: OFFICE BATH FB-3 DURATION INCREASE= 1,0,' BEAM SPAN (FT) = 12.0 VENEER(Y/N): NO TRIBUTARY LOADING SPAN(FT) CANT.(FT) WTL(PLFWIL(PLF) ROOF 13.0 1.5 323 202 FLOOR 16.0 0.0 416 320 FLOOR 0.0 0.0 0 0 DECK 0.0 0.0 0 0 OTHER 0.0 0.0 TOTAL 739 522 POINT LOAD RFACTIONS FROM LIGHT SH)E (TL) = 4437 LBS TL= 0 LBS (LL) � 3133 LBS LL= 0 LBS (IQ = 1304 LBS LOCATION (a) = 6.0 FT HEAVY SIDE (TL) = 4437 LBS b = I -a = 6.0 FT (a> b) (LL) = 3133 LBS EQUIV. UNIFORM TL = 0 PLF (]-')L) = 1304 LBS EQUIV. UNIFORM LL = 0 PLF Rrt/wTL = 6.0 FT Xl= 6.0 FT BEAM SUPPORT LIGHT SIDE: 3 HEIGHT (FT): ? SPOT FOOTING: Y HEAVY SIDE: 3 HEIGHT (FT): 9 SPOT FOOTING: Y STRUCTURAL COMPOSITE LUMBER TYPE: LVL (1.9E) DEPTH (d)est. = 117/8 IN. WIDTH (b)cst. = 13/4 IN. #OF MEMBERS = 2 MAX SUPPORT LOAD IN 4 STUDS 5990 LBS 1.75 Fr. SQR 21N.4 STUDS 5990 LBS 1.75 Fr. SQR Fb = 2,600 PSI Fv = 285 PSI E = 1.9013+06 PSI CF = 1.00 A = 41.56 IIN'(2) S = 82.26 IN(3) I = 488AI IN(4) FB -3 USE L(2) 1-3/4" X 1177—/8" LVL(S) SAFETY FACTOR 134 DESIGN LOADS FLAT ROOF SNOW LOAD TL 40 PSF LL 25 PSF FLOOKLOAD, TL 52 PSF LL 40 PSF DECKIOAD TL 710 PSF LL 60 PSF OTHERJ.OAD TL 125 PSF LL 50 PsF MAXIMUM MOMENT MmAx = 13,310 FT-LBS 8 CRITERIA: TL 5mAx: LL 5mAx: IJ 41�� &MAX @ 6.0 FT. (FROM LIGHT SEDE) TL &,� = 0.37 IN. U 387 LL6�= 0.26 11c U 549 AREQ. = 19.50 IN(2) SRZQ. = 61.43 IN(3) IREQ(TL) = 302.63 IN(4) IREQ(LL) = 320.55 N4) BRGREQ = 3 SIMPLE SPAN BEAM LOCATION: WIDE HEADER DESIGN LOADS FB- 2 FIAT ROOF SNOW LOAD TL 40 PSF DURATION INCREASE= 1.00 LL 25 PSF BEAM SPAN (FT) = 9.0 FLOOR LOAD TL 52 PSF VENEER(Y/N): NO LL 40 PSF TRIBUTARY LOADING DECKLOAD TL 70 PSF SPAN (Fr) CANT. (FT) W. (PLF WLL (PLF) LL 60 PSF ROOF 8.0 1.0 203 127 OTHERLOAD TL 125 PSF FLOOR 9.5 0.0 247 190 LL 50 PSF FLOOR 0.0 0.0 0 0 DECK 0.0 0.0 0 0 OTHER 0.0 0.0 TOTAL 450 317 POINTLOAD REACTIONS MAXIMUMMOMENT FROM LIGHT SIDE (TL) = 2023 LBS MMM= 4,551 FT-LBS TL— 0 LBS (LL) = 1425 LBS LL= 0 LBS (DL) = 598 LBS 8 CRITERIA: LOCATION (a) = 4.5 FT HEAVY SIDE (TL) = 2023 LBS TL SMAX- b=L.a= 4.5 FT (a> b) (LL) = 1425 LBS LL SMAX- EQUIV. UNIFORM TL = 0 PLF (DL) = 598 LBS EQUIV. UNIFORM LL = 0 PLF Rrt/wTL = 4.5 FT Xl= 4.5 FT BEAM SUPPORT MAX SUPPORT LOAD LIGHT SIDE: 2 STUDS 3800 LBS HEIGHT (Fr): 8 SPOT FOOTING: N FT. SQR HEAVY SIDE: 2 2 X16 STUDS 3800 LBS HEIGHT OM: 9 SPOT FOOTTNG: N FF. SQR STRUCTURAL COMPOSITE LUMMER TYPE: LVL (1.9E) DEPTH (d)est. = 9 1/2 IN. Fb = 2,600 PSI 4.5 FL (FROM LIGHT SII)E) WIDTH (b)est. = 13/4 IN. Fv = 285 PSI TL 8,�x = 0.14 IN. Ll 773 #OF MEMBERS = 2 E = 1-90F+06 PSI LL 6mAx = 0.10 IN. L/ 1098 CF = 1.00 A = 33.25 IN(2) AREQ. 8.77 K2) S= 52.65 IN(3) SREQ. 21.01 IN(3) I= 250.07 IN(4) IM(TL) 77.61 IN(4) 'IE9(LL) 81.99 IN(4) BRGREQ 3 IN. FB -2 USE 1(2) 1-3/411 X 9-1/211 LVL(S) SAFETY FACTOR 2.51 SIMPLE SPAN BEAM LOCATION: TYPICAL HEADER FB- I DURATION INCREASE= LOO BEAM SPAN 4.2 TRIBUTARY LOADING POINT LOAD SPAN(FT) CANT.(Fr) WTL(PLFWLL(PLF) ROOF 8.0 1.0 203 127 FLOOR 9.5 0.0 247 190 FLOOR 0.0 0.0 0 0 DECK 0.0 0.0 0 0 OTHER 0.0 0.0 TOTAL 450 317 REACTIONS FROM LIGHT SIDE (TL) = 944 LBS TL= 0 LBS (LL) = 665 LBS LL= 0 LBS (DL) = 279 LBS LOCATION (a) = 2.1 FT HEAVY SIDE (TL) = 944 LBS b=L-a- 2.1 Fr (a>b) (LL) = 665 LBS EQUIV. UNIFORM IT. = 0 PLF WL) = 279 LBS EQUIV. UNIFORM LL - 0 PLF Rrt/wTL = 2.1 FT BEAM SUPPORT LIGHT SIDE: 2 HEIGHT (FT): & SPOT FOOTING: N HEAVY SIDE: 2 HEIGHT (FT): 9 SPOT FOOTING: N DIMENSIONAL LUMBER TYPE: DFW2 DEPTH (d)est. = 71/4 IN. WIDTH (b)est. = 3 IN. X�= 2.1 Fr MAX SUPPORT LOAD ix", STUDS 3300 LBS Fr. SQR STUDS 3800 LBS FT. SQR CF = 1.2 Fb = 850 PSI Fv = 1,80 PSI E = 1.60F+06 PSI A = 21.75 LN(2) S = 26.28 IN(3) I = 95.27 IN(4) FB -1 USE 1(2) - 2 X 8 (S) I SAFETY FACTOR = 2.25 DESIGN LOADS FLAT ROOF SNOWLOAD IT, 40 PSF LL 25 PSF FLOOKLOAD IT, 52 PSF LL 40 PSF DECK -LOAD IT, 70 PSF LL 60 PSF OTHERJ,OAD TL 125 PSF LL 50 PSF MA)UMUM MOMENT MMAX = 991 FF-LBS 8 CRITERIA: TL 6�Ax: L/Ru, LL 6.: 11 4�ai 8MAX @ 2.1 F-T. (FROM LIGHT SII)E) TL6mAx= 0.02 IN. IJ 2441 LL41AX= 0.01 JK IJ 3466 AmQ. = 5.60 IN(2) SmQ. = 11.66 IN(3) IREOUL) = 9.37 IN(4) I.Q(LL) = 9,89 IN(4) BRGREQ. = 3 IN. ROOFBEAMN SIMPLE SPAN BEAM LOCATION: PORCH DESIGN LOADS RB -.3 FLAT ROOF SNOW -LOAD TL 40 PSF DURATION INCREASE= 1.15 LL 25 PSF BEAM SPAN (FI) = 15.5 FLOOkLOAD TL 52 PSF VENEER (Y/N): NO LL 40 PSF TRIBUTARY LOADING DECKLOAD TL 70 PSF SPAN OM CANT. (FT) WTL (PLF WLL (PLF) LL 60 PSF ROOF 3.0 1.0 107 67 OTHER -LOAD, TL 125 PSF FLOOR 0.0 0.0 0 0 LL 50 PSF FLOOR 0.0 0.0 0 0 DECK 0.0 0.0 0 0 OTHER 0.0 0.0 TOTAL 107 67 POINT LOAD FROM TL= 0 LL= 0 LOCATION (a) = 7.8 b=J-a= 7.8 EQUIV. UNIFORM TL = 0 EQUIV. UNIFORM LL = 0 REACTIONS LIGHT SIDE CIL) = 827 LBS LBS (LL) = 517 LBS LBS (DL) = 310 LBS FT HEAVY SIDE (TL) = 827 LBS FT (a> h) (LL) = 517 LBS PLF (DQ = 310 LBS PLF Rrt/wTL = 7.8 FT BEAM SUPPORT LIGHT SIDE: 2 HEIGHT (Fr): 9 SPOT FOOTING: N HEAVY SIDE: 2 HEIGHT (FT): 9 SPOT FOOTING: N STRUCTURAL COMTOSITE LUM33E TYPE: LVL (1.9E) DEPTH (d)est. = 91/2 IN. WIDTH (b)ca. = 13/4 IN. #OF MEMBERS = 2 ?0= 7.8 FT MAX SUPPORT LOAD 2k5 STUDS 3800 LBS FT. SQR 2,v� STUDS 3900 LBS Fr. SQR 1% = 2,600 PSI Fv = 285 PSI E = 1.90E+06 PSI CF = 1.00 A = 33.25 JN(2) S = 52,65 IN(3) I = 250.07 LN(4) lZB -3 USE 1(2) 1-3/4" X 9-1/2" LVL(S) SAFETY FACTOR 2.66 MAXIMUM MOMENT m,� 3,203 FT-LBS 6 CRITERIA: TL 6��: ii LL 6��: u &MAX @ 7.8 Fr. (FROM LIGHT SIDE) TL &MAX= 0.29 DL IJ 638 LL SMAX = 0.18 IN. IJ 1021 ARF,Q- = 3.40 IN(2) SRF.Q. = 12.86 IN(3) IREQ(TL) = 94.08 IK4) IREQ(LL) = 8S.20 IN(4) BRG,EQ = 3 IN. SIMPLE SPAN BEAM LOCATION: GARAGE HEADER RB- 2 DURATION INCREASE = J, 15 BEAM SPAN (FT) = 16.5 VENEER(Y/N): NO TRIBUTARY LOADING POINT LOAD SPAN (Fr) CANT. (FT) WTL (PLF Wu (PLF) ROOF 6.0 1.0 163 102 FLOOR 0.0 0.0 0 0 FLOOR 0.0 0.0 0 DECK 0.0 0.0 0 0 OTHER 0.0 0.0 TOTAL 163 102 REACTIONS FROM LIGHT SIDE (TL) = 1349 LBS TL— 0 LBS (LL) = 842 LBS LL= 0 LBS (DL) = 505 LBS LOCATION (a) = 8.3 FT HEAVY SIDE (TL) = 1348 LBS b=L-a= 8.3 FT (a> b) (LL) = 842 LBS EQUIV. UNIFORM TL = 0 PLF (DL) = 505 LBS EQUIV. UNIFORM LL = 0 PLF Rrt/wTL = 8.3 FT BEAM SUPPORT LIGHT SIDE: 2 HEIGHT (Fr): 8 SPOT FOOTING: N HEAVY SIDE: 2 HEIGHT (FT): 8 SPOT FOOTING: N STRUCTURAL COMPOSITE LUMBER TYPE: LVL (1.9E) DEPTH (d)est. = 117/8 IN. WIDTH (b)est. = 13/4 IN. #OF MEMBERS = 2 Xl= 8.3 FT MAX SUPPORT LOAD STUDS 3800 LBS Fr. SQR ".V, STUDS 3800 LBS FT. SQR Fb = 2,600 PSI Fv = 285 PSI E = 1-90F�106 PSI CF = 1.00 A = 41.56 INN(22) S = 82.26 IN(3) I = 488.41 IN(4) RB -2 USE 1(2) 1-3/4" X 11-7/8" LVL(S) SAFETY FACTOR 2.81 DESIGN LOADS FLAT ROOF SNOWLOAD TL 40 PSF LL 25 PSF FLOOR -LOAD TL 52 PSF LL 40 PSF DECKLOAD TL 70 PSF LL 60 PSF OTHERLOAD TL 125 PSF LL 50 PSF MAXIMUM MOMENT MMAX = 5,558 FT-LBS 6 CRITERIA: TL 5.: U LL.5.: U 8km @ 8.3 Ff. (FROM LIGHT SIDE) TL &MAX= 0.29 IN. U 675 LL kx = 0.18 IN. Li 1079 AREQ. = 5,43 IN(2) SRE,- = 22.31 IW3) IREQ(TL) = 173.77 IN(4) 1p,EQ(LL) = 16191 IN(4) BRGkEQ- = 3 IN SIMPLE SPAN BEAM LOCATION: TYPICAL HEADER RB - I DURATION INCREASE= LIS BEAM SPAN (FT) = 31 TRIBUTARY LOADING POINT LOAD SPAN UM CANT. (FT) WTL (PLF WIL (PLF) ROOF 20.0 2.0 484 30:3 FLOOR 0.0 0.0 0 0 FLOOR 0.0 0.0 0 0 DECK 0.0 0.0 0 0 OTHER 0.0 0.0 TOTAL 484 303 REACTIONS FROM LIGHT SIDE (TL) = 774 LBS TL� 0 LBS (LL) = 484 LBS LL= 0 LBS (DL) = 290 LBS LOCATION (a) = 1.6 FT HEAVY SIDE (TL) - 774 LBS b = L-a = 1. 6 FT (a> b) (LL) - 484 LBS EQUIV. UNIFORM TL � 0 PLF (DL) = 290 LBS EQUrV. UNIFORM LL � 0 PLF RrVwTL = 1-6 FT BEAM SUPPORT LIGHT SIDE: 2 HEIGHT (FT): 8 SPOT FOOTING: N HEAVY SIDE: 2 HEIGHT am: 8 SPOT FOOTING: N DIMENSIONA,L LUMBER TYPE:DFW2 DEPTH (d)est. = 7 114 IN. WIDTH (b)est. = 3 IN. DESIGN LOADS FLAT ROOF SNOWLOAD TL 40 PSF LL 25 PSF FLOORJ,OAD TL 52 PSF LL 40 PSF DECKI,OAD TL 70 PSF LL 60 PSF OTHERIOAD TL 125 PSF LL 50 PSF MAXIMUM MOMENT MMAX = 620 F7-LBS 6 CRITERIA: TL 6.: L/ L?4) LL 6,.: X!= 1.6 FT MAX SUPPORT LOAD ,,.y6 STUDS 3800 LBS Fr. SQR .,At, STUDS 3900 LBS FT. SQR CF = 1,2 Fb = 850 PSI 4AAX@ L6 Fr. (FROM LIGHT SIDE) Fv = 1.80 PSI TLkm= 0.01 IN. U 5126 E = 1-6013�1-06 PSI LLaMAX= 0.00 IN. U 9202 A = 21.75 IN(2) A,,q. = 3.49 N2) S = 26.28 IN(3) SRQ. = 634 Rq3) I = 95.27 IN(4) IRQ(rL) = 4.46 IN(4) IREq(LL) = 4A8 DK4) BRGREQ. = 3 IN. RB -1 USE 1(2) - 2 X 8 (S) I SAFETY FACTOR = 4.15 JOISTS SIWLE SPAN WOOD JOIST LOCATION: PORCH FJ- DECKLOADS DURATION INCREASE (D) = 1.00 DL= 10 PSF JOIST SPACING 0) = 16.0 IN. LL= 60 PSF JOIST SPAN = 12.5 Fr TL= 70 PSF LOADING(w) = 93 PLF(TL) 90 PLF(LL) REACTION = wTL*L/2 = 583.3333333 LBS wLL*L/2 = 500 L13S MAXIMUM MONIENT Mmax = [wTU8*12]/O)*Fb*CF) = 1,823 FFIBS JOIST SIZE GRADE: DF#2 Fb = 850 PSI DEPTH (d)est = 11.25 fN. Fv = 180 PSI WIDTH (b)est = 1.5 IN. Fc—L = 625 PSI E = L60E+06 PSI Areq 4.13 LN(2) C, 1.15 Steq = 22.38 IN(3) 0 0.0 Ireq(TL) = 51.27 IN(4) A 16.88 IN(2) Ireq(LL) = 65.92 IN(4) S 31.64 IN(3) BRGreq 3 IN. 1 377.98 IN(4) USE 2 X 16.0 IN. O.C.1 12 's SAFETY FACTOR = 1.41 FOOTINGS LOCATION DEAD LOAD LfVE LOAD TOTAL LOAD FOOTING SIZE CONT FxmRioR ROOF FTGS BEARING WALL WIDTH SPAN LOAD Fr Fr PSF LOAD PSF 0 x 0 @ 15 = 0 P LF (a), 25 = 0 PLF 0 PLF FLOOR WIDTH SPAN LADAD LOAD 890 PLF Fr Fr PSF PSF 1,500 PSF I x 6 @ 10 = 60 PlY @ 60 = 360 PLF 420 PLF WALL 0,6 Fr WIDTH HEIGHI LOAD Fr FT PU I x 18 @ 15 = 2-70 PLF 4270 PLF FOUNDATION USE AS MINIMUM THICK BEIGH] LOAD USE: FOOTlNG IN. FF PCF 8 x 2 @ 150 = 200 PLF 200 PLF V-8" X CONT 530 PLF 360 PIF 890 PIF LATERAL DESIGN LATERAL RESISTING SYSTEM: LIGH17-FRAME (WOOD) WIND DESIGN CRITERIA MWFRS DMECTIONAL PROCEDURE (ASCE 7-10, CHAP 27) BASIC WIND SPEED: 110 NTH FIG 26.5-IA VnND RISK CATEGORY: 11 EXPOSURE CATEGORY: C INT. PRESSURE COEF., GC�-: 0.18 TBL26.11-1 DIRECTION FACTOR, Kd: 0.85 TBL 26.6-1 fh'X, FACTOR, Y,: 1.0 26.9.2 7yTOPOGRAPHIC GUST -EFFECT FACTOR, G: 0.85 26.9.1 711 WINDWARD WALI. Cp: 0.8 TBL 27.4-1 Z': 900 SEISMIC DESIGN CRITERIA EQUIVALENT LATERAL FORCE PROCEDURE (ASCE 7-10,12.8) SEISIWC RISK CATEGORY: u SEISMIC DESIGN CATEGORY: DI IMPORTANCE FACTOR, 1: Lo SHORT PERIOD ACCEL, SDs: L291 ONE SEC PERIOD ACCEL, SDI: 0.506 ROOFLOAL RESPONSE MOD. COEF., R: 6.5 FLOOR LOAL DEFLECTION AMP. FACTOR, Cd: 4.0 WALL LOA-E OVERSTRENGTH FACTOR, f4: 3.0 DESIGN BASE SHEAR, V: 0.132 *W M, cpqn I'l. (p.r%F) 2-STORY ANALYSIS ZONE A WIND FORCES WIDTH, L = 10 FT DEPTH, B = 47,5 FT h = 22 FT ZZ � 18 FT GROUND TO ROOF EAVE ZI = 10 IT GROUND TO UPPER FLR Cpi � -0.2 FROM FIG. 27,4,1 CP2 = 0.� FROM FIG. 27*1 ROOFSLOFE 6/12 ROOF SLOPE 27 DEGREES b/L = 2.20 VELOCITY PRESS. COEF., K,: 0.88 TBL273-1 VELOCITY PRESS. COER, Kj: 0.85 TBL273-i VELOCITY PRESS. COEF., Kh: 0.92 TBL27.3-1 VELOCITY PRESS., qz2: 23.2 PSFEq,27.3-i VELOCITY PRESS., qzl: 22.4 PSF EQ- 27-3-1 VELOCITY PRESS., qh: 24.2 PSFEQ.z7.3-i ROOF PRESS., pl: -8.5 PSF ROOF PRESS., P2: 8.5 PSF ROOF DESIGN PRESS., pR: 3.8 PSFEQ.27.4-1 UPPER WALL DESIGN PRESS., PF2: �0.2 PSFEQ.27.4-1 MAIN WALL DESIGN PRESS., pFj: 19.6 PSFEQ-27-4-1 DESIGN AREA PRESSURE LOAD(LBS) ROOF 0.0 3.8 0 JPPERWALL 76.0 20.2 1532 MAINWALL 80.0 19.6 1565 TOTAL 3096 UPPER SHEAR WALL LOAD 1532 MAIN SHEAR WALL LOAD 3096 SEISMIC FORCES AREA WEIGHTS ZONE IR m (PRM WFfr-]RT a.Rq) ROOI _LWAU JJWAU FLOOR _LWALl 11 WALI 391.0 15 5865 80.0 17 1360 126.0 17 2142 255.0 12 3060 80.0 7 117 1360 190.0 3230 TOTALI 17017 UPPER SHEAR WALL LOAD 1241 IBS MAIN SHEAR WALL LOAD 2254 LBS ROOF DIAPHRAGM. DIAPHRAGM LOAD = 1532 LBS SHEAR LENGTH = 47.5 FT DIAPHRAGM SHEAR = 32 PLF FLOORDlAPHRAGM DIAPHRAGM LOAD = 1565 LBS SHEAR LENGTH = 47,5 FT DIAPHRAGM SHEAR = 33 PLF ROOF DIAPHRAGM DIAPHRAGM LOAD = 95- LBS SHEAR LENGTH = 47.5 FT DIAPHRAGM SHEAR = 20A PLF FLOORDIAPHRAGM DIAPHRAGM LOAD = 585�5 LBS SHEAR LENGTH = 47.5 FT DIAPHRAGM SHEAR = 12.3 PLF UPPER SHEAR WALL LOADS WIND SHEAR LOAD = TOTAL LOAD/1.4 SEISMIC SHEAR LOAD SEISMIC GO NS 1094 LBS 1241 LBS SW HEIGHT 8 FT ;HEAR LOAD 1241 LBS 0 LBS RESISTED BY PANELS/P.F. MEAR LOAD 1241 LBS RESISTED BY SW NET WALL TRIB. UNIFORM PT LOAD OVERTURN UPLIFT CAPACITY SHEAR LENGTH SPAN DL (PLF) (LBS) (FT -LB) (LJ3S): STRAP TIE REQUIRED WALL 11.9 10.0 286 715 -22701 -1908 NOT REQ'D 64 Sw-1 4.3 10.0 286 715 -3530 -821 NOT REQ'D 64 SW_1 3.3 2.0 166 415 -594 -180 NOT REQ'D 77 SW -I TOTALLENGTH= 19,5 FT OVERALL WALL SHEAR 64 PLF MAIN SHEAR WALL LOADS WIND SHEAR LOAD = TOTAL LOAD/1.4 SEISMIC SHEAR LOAD SEISMIC GOMR-N-S-1 2 2212 LBS 2254 LBS SW HEIGHT 8 FT MAX LOAD 2254 LBS 0 LBS RESISTED BY PANELS/P.F. HEAR LOAD 224-:4 LBS RESISTED BY SW PTLOAD NET S.W. WALL TRIB. FORCE UNIFORM EACH SIDE OVERTURN UPLIFT CAPACITY LENGTH SPAN ABOVE DL (PF) (LBS) (FT -LB) FORCE HOLDOWN REQUIRED 31.5 1.0 151 377.5 -68773 -2183 NOT REQ'D 72 TOTALLENGTH= 31.5 FT OVERALL WALL SHEAR =1 72 P SHEAR WALL Sw-1 2-STORY ANALYSIS ZONE B WIND FORCES WIDTH, L = 25.5 FT DEPTH, B = 47.5 FT h = 22 FT Z2. = 18 FT GROUND TO ROOF EAVE ZI = 10 FT GROUND To UPPER FLR Cpt = -0.2 FROM FIG. 27A-1 Cp2 = 0.2 FROM FIG. 27.4-1 ROOF SLOPE 6 /12 ROOFSLOFE 27 DEGREES n= 0.86 VELOCITY PRESS. COEF., K,: 0.88 TBL27.3-1 VELOCITY PRESS. COEF., Kj: 0.85 TBL27.3-1 VELOCITY PRESS. COEF., Kh: 0.92 TBL27.3-1 VELOCITY PRESS., q,2: 23.2 PSFEq273-i VELOCITY PRESS., q,,: 22.4 PSF EQ. 273-1 VELOCITY PRESS., qh: 24.2 PSF EQ- 27-3-1 ROOF PRESS., pl: -8.5 PSF ROOF PRESS., P2: 8.5 PSF ROOF DESIGN PRESS., PR: 3.8 PSFEQ.27.4-i UPPER WALL DESIGN PRESS., p,: 20.2 PSFEQ.27A.1 MAIN WALL DESIGN PRESS., PFl: 19.6 PSFEQ.27A-1 DESIGN AREA PRESSURE LOAD (LBS) ROOF 90.0 3.8 341 JPPERWALL 138.0 1 20.2 2781 MAIN WALL 204.0 19.6 3990 TOTAL 7113 UPPER SHEAR WALL LOAD 3123 MAIN SHEAR WALL LOAD 7113 SEISMIC FORCES AREA WEIGHTS ZONE ISM (p.qvl WFlr.T-TT a.R.q) ROOT -LWALI 11 WALL FLOOR _LWALl 11 WALI 1217.0 15 18255 204.0 17 3468 68.0 17 1156 690.0 12 8280 2040 17 3468 52.0 17 884 TOTALI 35511 UPPER SHEAR WALL LOAD 3031 LBS MAIN SHEAR WALL LOAD 4704 LBS ROOF DIAPHRAGM DIAPHRAGM LOAD = 3123 LBS SHEAR LENGTH = 47.5 FT DIAPHRAGM SHEAR = 66 PLF FLOORDL&PHRAGM DIAPHRAGM LOAD = 3990 LBS SHEAR LENGTH = 47.5 FT DIAPHRAGM SHEAR = 84 PLF ROOF DIAPHRAGM DIAPHRAGM LOAD = 2877 lBS SHEAR LENGTH = 47.5 FT DIAPHRAGM SHEAR = 60.6 PLF FLOOR DIAPHRAGM DIAPHRAGM LOAD = 1556-2 LBS SHEAR LENGTH = 47.5 FT DIAPHRAGM SHEAR = 32.8 PLF UPPER SHEAR WALL LOADS WIND SHEAR LOAD = TOTAL LOAD/1.4 SEISMIC SHEAR LOAD SEISNHC GOVEPUNS 2230 LBS 3031 LBS SW HEIGI-IT 8 FT REAR LOAD 3031 LBS 0 LBS RESISTED BY PANELS/P.F. 1HEARLOAD 3031 LBS RESISTED BY SW WALL TRIB. UNIFORM PT LOAD LENGTH SPAN DL (PLF) (LBS) 7.3 10,0 286 715 9.6 3.0 181 452.5 MAIN SHEAR WALL LOADS WIND SHEAR LOAD = TOTAL LOAD/lA 5081 LBS NET OVERTURN UPLIFT (FT -LB) (LBS): -2367 -324 1088 113 CAPACITY SHEAR STRAP TIE REQUIRED WALL NOTREQ'I) 179 Sw-I ST-1 179 SW-1 TOTAL LENGTH 16.9 FT OVERALL WALL SHEAR 179 PLF SEISMIC SHEAR LOAD WM GOVERNS 4'704 LBS SW HEIGHT 8 FT MAX LOAD 5081 LBS 0 LBS RESISTED BY PANELS/P.F, MEAR LOAD 5081 LBS RESISTED BY SW PTLOAD NET WALL TRIB. FORCE UNIFORM EACH SIDE OVERTURN LENGTH SPAN ABOVE DL (PF) (LBS) (FT -LB) 13.0 1.0 151 377.5 6350 9.0 1.0 151 377.5 7114 S.W. UPLIFT CAPACITY SHEAR FORCE HOLDOWN REQUIRED WALL 488 HD -I 231 Sw-I 790 HD -I 231 Sw-1 TOTALLENGTH= 22.0 Fr OVERALL WALL SHEAR =1 231 PLF 2-STORY ANALYSIS ZONE c WIND FORCES WIDTH, L = 25.5 FIP DEPTH, B = 37.5 FT h = 22 FT Z2 = 18 FT GROUND io ROOF EAvE Zl= 10 FT GROUND TO UPPER FLR Cpi = -01 FROM FIG� 27.4-1 Cp2 = 0.2 FROMFIG.27.4-1 ROOF SLOPE 6/12 ROOF SLOPE 27 DEGREES h/L = 0.86 VELOCITY PRESS. COEF., Ka: 0.88 TBL27.3-1 VELOCITY PRESS. COEF., &1: 0.82) TBL27.3-1 VELOCITY PRESS. COEF., Kh: 0.92 TBL27.3-1 VELOCITY PRESS., q,2: 23.2 PSFEQ.27-3-i VELOCITY PRESS., q�j: 22.4 PSF EQ. 27-3-1 VELOCITY PRESS., qh: 24,2 PSF EQ- 27.3-1 ROOF PRESS., p 1: -8.5 PSF ROOF PRESS., p2: 9.5 PSF ROOF DESIGN PRESS., pR: 3.8 PSFEQ.27*j UPPER WALL DESIGN PRESS., P12: 20.2 PSF EQ. 27.4-1 MAIN WALL DESIGN PRESS., PFI: 19.6 PSFEQ-27.4-1 DESIGN AREA PRESSURE LOAD (LBS) ROOF DIAPHRAGM ROOF 60.0 3.8 228 DlAPHRAGM LOAD = 3009 LBS JPPERWALL 138.0 20.2 2781 SHEAR LENGTH = 37.5 FT MAIN WALL 204.0 1 19.6 3990 DIAPHRAGM SHEAR = 80 PLF TOTAL 6999 FLOOR DIAPHRAGM UPPER SHEAR WALL LOAD 3009 DIAPHRAGM LOAD = 3990 LBS MAIN SHEAR WALL LOAD 6999 SHEAR LENGTH = 37.5 FT DIAPHRAGM SHEAR = 106 PLF SEISMIC FORCES AREA WEIGHTS ZONE (SF) (PSF) IGHT (LBS) ROOF DIAPHRAGM ROOF _LWALL 11 WALL FLOOR _LWALL 11 WALL 1188.0 15 17820 204.0 17 3468 150.0 17 2550 779�5 12 9354 204.0 17 3468 1 150.0 17 1 2550 DIAPHRAGM LOAD = 2820 LBS SHEAR LENGTH = 37.5 FT DIAPHRAGM SHEAR = 75.2 PLY FLOOR DIAPHRAGM DIAPHRAGM LOAD = 1698.4 LBS SHEAR LENGTH = 37.5 FT TOTALI 39210 DIAPHRAGM SHEAR 45.3 PLF UPPER SHEAR WALL LOAD 3158 LBS MAIN SHEAR WALL LOAD 5194 LBS UPPER. SHEAR WALL LOADS WIND SHEAR LOAD TOTAL LOAD/1.4 SEISMIC SHEAR LOAD 2149 LBS 3158 LBS SW HEIGHT 8 FT 1HEARLOAD 3158 LBS 0 LBS RESISTED BY PANELS/P.F. �HEARLOAD 3158 LBS RESISTED BY SW NET WALL TRIB. UNIFORM PTLOAD OVERTURN UPLIFT LENGTli SPAN DL (PLF) (LBS) (FT -LB) (LBS): 3.2 4,0 196 490 3081 963 7.3 4.0 196 490 4096 561 3.8 4.0 196 490 3436 904 I SEISMIC G CAPACITY SHEAR STRAP TIE REQUIRED WALL ST-1 276 SW-2 ST-1 221 SW-1 ST-1 232 Sw-I TOTALLBNGTH= 14.3 FT OVERALL WALL SHEAR 221 PLF MAIN SBEAR WALL LOADS WIND SHEAR LOAD TOTAL LOAD/1.4 SEISMIC SHEAR LOAD SEISMIC GOVE 7NTS 4999 LBS 5194 LBS SW HEIGHT 8 FT MAX LOAD 5194 LBS 0 LBS RESISTED BY PANELS/P.F. ,HEAR LOAD 51,94 L13S RESISTED BY SW PTLOAD NET S.W. WALL TRIB. FORCE UNIFORM EACH SIDE OVERTURN UPLIFT CAPACITY SHEAR LENGTH SPAN ABOVE DL (PF) (LBS) (FT -LB) FORCE HOLDOWN REQUIRLD WALL 11.0 1.0 15 1 377.5 12389 1126 IED-2 292 SW-2 6.8 1.0 151 377.3 9815 1443 HD-2 292 SW-2 TOTALLENGTH= 17.8 FT OVERALL WALL SHEAR =1 292 PLF 2-STORY ANALYSIS ZONE 1 WIND FORCES Vy'IDTH, L = 16 FT DEPTH, B = 20 FT h = 22 FT Z2 � 18 FT GROUND TU ROOF EAVE Zl= 10 FT GROUND TO UPPER FLR CPl = -0.2 FROM FIG- 27.4-1 CP2 = 0.2 FROM FIG. 27.4.1 ROOF SLOPE 6/12 ROOFSLOFE 27 DEGREES h/L = 1.38 VELOCITY PRESS. COEF., K,,: 0.88 TBL27.3-L VELOCITY PRESS. COEF., Kj: 0.85 TBL27.3-1 VELOCITY PRESS. COEF., Kh: 0.92 TBL27.3-1 VELOCrI'Y PRESS., q,2: 23.2 PSF EQ. 27.3.1 VELOCITY PRESS., qj: 22.4 PSF EQ. 27.3-1 VELOCITY PRESS., qh: 24,2 PSF EQ. 273.1 ROOF PRESS., pl: -8.5 PsF ROOF PRESS., p2: 8.5 PSF ROOF DESIGN PRESS., PR: 3-8 PSFEQ-27.4-1 UPPER WALL DESIGN PRESS., p,: 20.2 PSFEQ.27-4-i MAIN WALL DESIGN PRESS., pFj: 19.6 PSFEQ-z7-4-i DESIGN AREA PRESSURE LOAD(LBS) ROOF 84.0 3.8 319 JPPERWALL 52.0 20,2 1048 MAINWALL 232.0 19.6 4538 TOTAL 5904 UPPER SHEAR WALL LOAD 1367 MAIN SHEAR WALL LOAD 5904 SEISMIC FORCES AREA WEIGHTS ZONE ten fpcm vvvlllu� a me% ROOI _LWALl 11 WALI FLOOR _LWALl 11 WALI 429.0 is 6435 104.0 17 1768 80A 17 1360 260.0 12 3120 152.0 11 2584 80�O 17 --r 11160 TOTALI 16627 UPPER SHEAR WALL LOAD 1267 LBS MAIN SHEAR WALL LOAD 2202 LBS ROOF DIAPHRAGM DIAPHRAGM LOAD = 1367 LBS SHEAR LENGTH = 20.0 FT DIAPHRAGM SHEAR = 68 PLF FLOOR DIAPHRAGM DIAPHRAGM LOAD = 4538 LBS SHEAR LENGTH = 20.0 FT DIAPHRAGM SHEAR = 227 PLF ROOF DIAPHRAGM DIAPHRAGM LOAD = 1087 LBS SHEAR LENGTH = 20.0 FT DIAPHRAGM SHEAR = 54.3 PLF FLOOR DIAPHRAGM DIAPHRAGM LOAD = 755.6 LBS SHEAR LENGTH — 20.0 FT DIAPHRAGM SHEAR = 37.9 PLF UPPER SHEAR WALL LOADS WIND SHEAR LOAD= TOTAL LOAD/1.4 SEISMIC SHEAR LOAD SEISMIC GoNTrRNs 9-70 LBS 1267 LBS SW HEIGHT 8 FT 'HEAR LOAD 1267 LBS 0 LBS RESISTED BY PANELS/P.F. HEAR LOAD 1267 LBS RESISTED BY SW NET WALL TRIB. UNIFORM PTLOAD OVERTURN UPLIFT CAPACITY SHEAR LENGTH SPAN DL (PLF) (LBS) (FT -LB) (LBS): STRAP TIE REQUIRED WALL 6.2 2.0 166 415 -697 -112 NOT REQ'D 101. SNv-1 6.2 2.0 166 415 -697 -112 NOT REQ'D 102 Sw-1 TOTALLENGTH= 12.4 FT OVERALL WALL SHEAR =1 102 PLF MAIN SHEAR WALL LOADS WIND SHEAR LOAD = TOTAL LOAD/1.4 SEISMIC SHEAR LOAD WLN-D GOV F-R-,N—'S 4217 LBS 2202 LBS SW HEIGHT 8 FT MAX LOAD 4217 LBS 3350 LBS RESISTED BY PANELS/P.F. HEAR LOAD 867 LBS RESISTED BY SW PTLOAD NET S.W. WALL TRIB. FORCE UNIFORM EACH SIDE OVERTURN UPLIFT CAPACITY SHEAR LENGTH SPAN ABOVE DL (PF) (LBS) (FT -LB) FORCE HOLDOWN REQUIRED WALL 2.0 5.0 211 527.5 5462 27731 HD4 867 Sw-5 TOTAL LENGTH 2.0 Fr OVERALL WALL SHEAR 434 2-STORY ANALYSIS ZONE 2 WIND FORCES WIDTH, L = 16 FT DEPTH, B = 20 FT h = 22 Fr 2� = 18 FTGRouND TO ROOF EAVE Zl= 10 FT GRouND To uPPER FLR Cpl= -0.2 momm.27.4-i CP2 � 0.2 FROMFIG.27.4-i ROOF SLOPE 6/12 ROOF SLOPE 27 DEGREES h/L = 1.38 VELOCITY PRESS. COEF., Ka: 0.88 TBL27-3-1 VELOCITY PRESS. COEF., Kj: 0.85 TBL27.3-1 VELOCITY PRESS. COEF., 4: 0.92 TBL27.3-1 VELOCITY PRESS., qa: 23.2 PSF EQ� 273-1 VELOCITY PRESS., q,,: 22 A PSF EQ. 273-1 VELOCITY PRESS., qh: 242 PSFEQ-273-1 ROOF PRESS., pl: -8.5 PSF ROOF PRESS., P2: 8.5 PSF ROOF DESIGN PRESS., PR: 3.8 PSFEQ-27-4-1 UPPER WALL DESIGN PRESS., pFz: 20,2 PSFEQ.27.4-i MAIN WALL DESIGN PRESS., PFI: 19,6 PSFEQ.27.4-i DESIGN AREA PRESSU" LOAD(LBS) ROOF 84.0 3.8 319 JPPERWALL 52.0 20.2 1048 MAINWALL 232.0 19.6 4538 TOTAL 5904 UPPER SHEAR WALL LOAD 1367 MAIN SHEAR WALL LOAD 5904 SEISMIC FORCES AREA WEIGHTS ZONE (Qm 11pqm WRIC-UT fF R10 ROOT _LWALl 11 WALI. FLOOIR _LWALl 11 WALI 429.0 15 6435 104.0 17 1768 80.0 17 1360 260.0 12 3120 1520 1'7 2594 8 17' 1360 -1 TOTALI 16627 UPPER SHEAR WALL LOAD 1267 LBS MAIN SHEAR WALL LOAD 2202 IBS ROOF DIAPHRAGM DIAPHRAGM LOAD 1367 LBS SHEAR LENGTH 20.0 FT DIAPHRAGM SHEAR 68 PLF FLOORDIAPHRAGM DIAPHRAGM LOAD = 4538 LBS SHEAR LENGTH = 20.0 FT DIAPHRAGM SHEAR = 227 PLF ROOF DIAPHRAGM DIAPHRAGM LOAD = 108-1 LBS SHEAR LENGTH = 20.0 FT DIAPHRAGM SHEAR = 54.3 PLF FLOORDIAPHRAGM DIAPHRAGM LOAD = 755.6 LBS SHEAR LENGTH = 20.0 FT DIAPHRAGM SHEAR = 37.8 PLF T ' ' ..' UPPER SHEAR WALL LOADS WIND SHEAR LOAD= TOTAL LOAD/1.4 SEISMIC SHEAR LOAD SEISMIC G 976 LBS 1267 LBS SW HEIGHT 8 FT 1HEARLOAD, 1267 LBS 0 LBS RESISTED BY PANELS/P.F. ;HEARLOAD 1267 LBS RESISTED BY SW NET WALL TRIB. UNIFORM PT LOAD OVERTURN LENGTH SPAN DL (PLF) (LBS) (FT -LB) 20.0 4.0 196 490 -38866 MAIN SHEAR WAILL LOADS WIND SHEAR LOAD = TOTAL LOAD/1.4 4217 LBS UPLIFT CAPACITY SHEAR (LBS): STRAP TIE REQUIRED WALL -1943 NOT REQ'D 63 sw-I TOTALLENGTH= 20.0 FT OVERALL WALL SHEAR =1 63 P�LF SEISMIC SHEAR LOAD NVLND GO 2202 LBS SW HEIGHT 8 FT MAX LOAD 4217 LBS 0 LBS RESISTED BY PANELS/P.F. MEAR LOAD 4217 LBS RESISTED BY SW PTLOAD NET WALL TRIB. FORCE UNIFORM EACH SIDE OVERTURN LENGTH SPAN ABOVE DL (PF) (LBS) (FT -LB) 6.0 4.0 196 490 27271 S.W. UPLIFT CAPAC17Y SHEAR FORCE HOLDOWN REQUIRED WALL 4545 IED-5 703 SW-5 TOTALLENGTH= 6.0 FT OVERALL WALL SHEAR =1 703 PLF 2-STORY ANALYSIS ZONE 3 WIND FORCES WIDTH, L = 19 FT DEPTH, B = 55 FT h = 22 FT k 18 FT GROUND TO ROOF EAVE ZI 10 FT GROUND TO UPPER FLR Cpi -0.2 FROMFIG.27.4.1 Cp2 0.2 FKOMFIG�27.4-1 ROOF SLOPE 6/12 ROOF SLOPE 27 DEGREES h/L = 1.16 VELOCITY PRESS. COEF., K72: 0.88 THL27.3-1 VELOCITY PRESS. COEF., Kj: 0.8.5 TBL273-1 VELOCITY PRESS. COEF., Kh: 0.92 TBL27.3-1 VELOCITY PRESS., q,2: 23.2 PSF EQ. 27.3-1 VELOCITY PRESS., qzl: 22.4 PSF EQ. 27.3-1 VELOCITY PRESS., qb: 24,2 PSF EQ. 27.3-1 ROOF PRESS., pl: -9.5 PSF ROOF PRESS., P2: 8.5 PSF ROOF DESIGN PRESS., PR: 3.8 PSFEQ.27A-1 UPPER WALL DESIGN PRESS., pn: 20.2 PSFW.27.4,i MAIN WALL DESIGN PRESS., PFI: 19,6 PSFEQ.27.4.i DESIGN AREA PRESSURE LOAD (LBS) ROOF 87.8 3.8 333 JPPERWALL 76.0 20.2 1532 MAINWALL 152.0 19.6 2973 TOTAL 4838 UPPER SHEAR WALL LOAD 1864 MAIN SHEAR WALL LOAD 4838 SEISMIC FORCES AREA WEIGHTS ZONE Pq m ip.qvl WRICTIT fF.Rll ROO] _LWALI 11 WALI FLOOl _LWALI 11 WALI 1060.0 15 15900 152.0 17 2584 76.0 17 1292 601.0 12 7212 152.0 7 117 1 2584 220�O 1 3740 TOTALI 33312 UPPER SHEAR WALL LOAD 2620 LBS MAIN SHEAR WALL LOAD 4413 LBS ROOF DL&PHRAGM DIAPHRAGM LOAD = 1864 IBS SHEARLENGTH= 55.0 FT DIAPHRAGM SHEAR = 34 PLF FLOOR DIAPHRAGM DIAPHRAGM LOAD = 22973 LBS SHEAR LENGTH = 55.0 FT DIAPHRAGM SHEAR = 54 PLF ROOF DIAPHRAGM DIAPHRAGM LOAD = 2448 13S SHEAR LENGTH = 55.0 FT DIAPHRAGM SHEAR = 44.5 PLF FLOOR DIAPHRAGM DIAPHRAGM LOAD = 1297-6 LBS SHEAR LENGTH = 55�O FT DIAPHRAGM SHEAR = 23.6 PLF UPPER SHEAR WALL LOADS WIND SHEAR LOAD = TOTAL LOAD/1.4 SEISMIC SHEAR LOAD SEISMIC 3-07EMN-771 S 1332 LBS 2620 LBS SW HEIGHT 8 FT HEAR LOAD 2620 LBS 0 LBS RESISTED BY PANELS/P.F. :HEAR LOAD 2620 LBS RESISTED BY SW NET WALL TRIB. UNIFORM PTLOAD OVERTURN UPLIFT CAPACITY SHEAR LENGTH SPAN DL (PLY) (LBS) (FT -LB) (LBS): STRAP TIE REQUIRED WALL 14.3 4.0 196 490 -10848 -759 NOT REQ'D 142 SW-1 4.2 4.0 196 490 971 231 ST-1 142 SW-1 TOTAL LENGTH 18.5 FT OVERALL WALL SHEAR 142 P MAIN SHEAR WALL LOADS WIND SHEAR LOAD = TOTAL LOAD/1 .4 SEISMIC SHEAR LOAD "S ISNUC GOVERNS 3455 LBS 4413 LBS SWHEIGHT 8 FT MAX LOAD 4413 LBS 0 LBS RESISTED BY PANELS/P.F. 1HEARLOAD 4413 LBS RESISTED BY SW PTLOAD, NET S.W. WALL TRIB, FORCE UNIFORM EACH SIDE OVERTURN UPLIFT CAPACITY SHEAR LENGTH SPAN ABOVE DL (PF) (LBS) (FT -LB) FORCE HOLDOWN REQUIRED WALL 3.9 4.0 196 490 5312 1362 HD-2 286 SW-2 4.1 4.0 196 490 5504 1342 HD-2 279 SW-2 3,5 4.0 196 490 4904 1401 HD-2 319 SW-2 4.3 4.0 196 490 5688 1323 HD-2 2", 9 SW-2 TOTALLENGTH= 1S.9 FT OVERALL WALL SHEAR 279 PT�F Alison & James Pope 18209 76th Ave W., Edmonds, WA 98026 Lot I Area = 0.32 Acres Snohomish County Parcel Record: 00370800300500 Short Subdivision: SP 83-1091 Residential Zone: RS-12 Minimum Building Setbacks (16.20.030) Front (W) Rear (E) Side (N) Side (S) Max Hei�t 25 Ift 25 ft loft loft 25 Ift 17. J/ /'T"� SITE PLAN SCALE: V = 19 RIGHT-OF-WAY CONSTRUCTION PERMIT AND INSPECTION REQUIRED OWNER/GO ACTOR RESPONSIBLE FDR LOCAT ING ALL ON -SITE UTILITIES. RELOCATIOWRIEVISION TO ANY UTILITIES MAY REQUIRE SEPARATE PERMIT Applicant shall r"108plece all damage: to: utilities or front -age Improvements in City W right-of,vay rper c�ity Eandards that is caused ng In 1. or occurs during the permittad project. Per UPC 703.2 of fixture Un[ pipe IF Lasaltq(' vF Slog- srwvt 15, SF?Pt)R.Anttj (LzkUA(1,TMr71�M Foo- WA-MV NOD Sr"Pca- fAft'( A?M' I SEWER MAIN: 6-39-5-325A 251-0,, Front vi a, Sides N V. !6 �Q A) I '- " 5 - Rea, E Other Height APPROVED BY ENGINEERING I 1-Ut It SITE PLAN NOTES 1. THIS IS NOT AN OFFICIAL SURVEY, ANY CONTOURS SHOWN HEREIN ARE BASED ON AVAILABLE DATA. THIS ARCHITECTURAL SITE PLAN SHOULD BE SUFFICIENT FOR THE RELATIVE COMPLEXITY OF THE CONTRACTOR/OWNER TO VERIFY THE INFORMATION AND OBTAIN AN OFFICIAL SURVEY EFNEEDED. 2. SURFACE WATER SHALL DRAIN AWAY FROM THE HOUSE AT ALL POINTS. DIRECT THE DRAINAGE WATER TO THE STREET OR TO AN APPROVED DRAINAGE COURSE. 3. STOCKPILE TO BE COVERED W11HIN 24 HOURS 4. FILTER SOCKS WILL BE ADDED TO ANY CATCH BASINS DOWNSTREAM FROM THE CONSTRUCTION SITE (SEE 3/A-01 1) 5. ALL DISTURBED SOIL WILL BE COMPOST, AMENDED PER BMI` T5.13 6. ALL FINAL RESTORATION TO BE COMPLETED BY CONTRACTOR, NOT CITY OF EDMONDS 7. TRACER WIRE TO BE INSTALLED ON NEW WATER SUPPLY LINE 8. HEIGHT CERTIFICATE: SEE 4/A-01 I SITE PLAN LEGEND PROPERTY LINES - — — — — — — -- SETBACK LINES ------------------------ EASEMENT LINES WATERLINE SFWFR/WASTE LINES GAS LINES ELECIRICAL LINES TELEPHONE LINES SLOPE DOWN DIRECTION UTILITY METER IMPERVIOUS SURFACE CALCS (SOLID SURFACES) EXISTING BUILDING FOOTPRINT: 1,822 SF PROPOSED ADDITION: 365 SF PROPOSED COVERED PORCH: 391 SF PROPOSED DRIVEWAY: 332 SF PROPOSED PAVING/WALKWAY: 299 SF BUILDING DATA PROPOSED ALLOWABLE NETLOTAREA 12,114 SIP 0.28 AC (MINUS ACCESS EASEMENT) STRUCTURED AREA 2,578 SF 21.28% (BUILDING FOOTPRINT) IMPERVIOUS AREA 3,209 SF 26.50% 35.00% (LOT COVERAGE) LOT SLOPE 4% 'PEPCENTAGES ARE BASED ON LOT SIZE RESUB (CfV C'07'1 JUN 0 6 2019 BUILDING DEPARTMENT CITYOFEUMONDS 40 West Main Stres' Lehi, UT 84043 office@tiekd�igngroup­ 0 Copyriglit 2018 Twk Dmign Grop, LLC. All Righis Re—d Pj_ _'—w— --I —d Uffi. 116ghu.—d- dklnb­, 'PiW,.­1.d,­­d­yp,­ D�k DmI, Txk _P_P_... " 'W" ­­­ d. ip Irnly — ... ­ ­Wi­ i� ­ P'. .1. E­ ff.ft i 11 b� i. d., ft j, I h I l'i 'ty'. I I h.'. —2=,'� Z i ly i I ­. —.1— A.1 I ­fi�mi d.ft p— W ­1y di—!i— & .-mg �B. PH. PERMIT SET - REV 05 6/4/2019 6/4/2019 5 ­N BY COLBYDALLEY STEVE TIEK SITE PLAN Flim MIN RADIUS DETAIL NOTES Rfl� STALLS * WIN DIA, MIN DEPTH (DTHE MUMUM LENGTH SHALL BE EXTENDED AS NECES!LIW 10 ENSURE MAIEAX IS NOT IRXKE0 OFF SHE AND/OR INTO THE puguc at;Hr-or-w4y, ATI) DRIVEWAY UMP AND/OA SITE ACCESS ROAD 1V WIDE WN. SEE FASUE BELOW FOR REQUIRED LENGTH NOTES, 1. SURFACE WATER - AL SURFACE WATER FLOWING OR DIVERTED TOWARD tONSTR CRON ENTRANCES SHPALL BE PIPED ACROSS THE ENTRANCE. IF AppIc IS AHUGHM, A LICLINTATILE BEAM WITH 5:1 SIOPES WILL BE PERMHArD 2.MA1 ICURCE - THE ENTRANCE SHAUL BE MAIMINNED 1. A CONDITION IT iC. WILL PREN,CNT TRACKING OR FLO 'NO OF SED�ENH OFF SITE AND/OR ONTO PUWD-C THIS WAV' REQUIRE PERIODIC TOP CRESVINO WTH ADDITIONAL 4LARRY SPALLS AS CONDITIONS DEMAND AND REPAIR AND/Of, CLUATNOUT OF AN`V MEASURES USED TO Imp SEDIMENT. ALL SEDIMENT SPILLED. DROPPED, WASHED OR TRACKED OFF SITE AAO/DR ONTO PUQUO HICHI-OF-MY MUST BE REMONIED IMMEDAITELY. 3.WEELS SmoLL BE CLEATIED TO REMONH SEDIMENT PRIOR TO LEAWNS THE SITE. WHEN WASHING ;S USED. IT SMALL BE DONE ON AN AREA STABILIZED WITH OLLNUPY SPALLS AND WHICH DUNS INTO AN APPROVED SEDIMENT TRAPPING DEV'CE. 4.114SPECTION AND NEEDED MATt4ENAINCE SHAtL BE PAWDED AFTUR EACH ANN PRINECT MIN LENGTH OF (FEET) -PROVIDE AT9 OR ASP LT SIZE QUI SPALLS. TRANSIT' . -ERE NTAGE < 1/4 ACRE 3. AM 15 AN ARTERIAL. LEN Th TO [At DETERMINED < 1 ACRE 50 V CRY INSPECTOR. S ECIHON REOUIRED ON < 3 MAE 100 ALL ER SION ONTROL MET14ODS � 3 ACRE 100 1 CBEITFYOR"ElOPOTHERC WORI( CAN BEGIN FILTER FASRC SEEL TO 2 2* 14 GIN WIRE FABRIC EQUAL WWVE aACKFIU- FILTE FABRIC MATERX IN CO�.NDQS ROLLS USE SlAALCS OR WIRE AND$ TO ATTACH FABRIC TO II Z' � 2' WDOD/STEEL KSIS-� WIRE MESH FENCE TO SUP CRT FILTER FABRIC 11:: a BUW BORROW OF FILTER MIXERPIL 4* TO 12' 1. CONIUCTOR/DEVELOPEA SHVIUL "MINN AND ENSURE PAOPER mosIoN CONTROL THROUGHOUT PROUECT. 2. SILT FEN E TO BE PLACED DOWNSLOPE OF CONSTRUCTION ActIm. STABILIZED CONSTRUCTION ENTRANCE (ER-901) FILTER FABRIC FENCE FILTRATION SYSTEM (ER-900) SCALE:NTS SCALE: NTS FILTER STICK WITH MY HOLES �CXTCH BASIN NOTES1 1. C07MX PER SHkUL MAINTAIN THS AVW JIMO T 4 L TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH SMIN INSERT SHAUL BE A OVED WHEN $11SEAT IS ONE-THTAV FULL 3. CIW IN5AEGTION REGUIREO ON ALL DAWIC CONTROL METHODS BEFORE OTHER WAIT �N DEOHL TEMPORARY SEDIMENT TRAP FOR CATCH BASINS (ER-902) SCALE: INITS HF-)�-HT CEJ:�-J/FICATL PROPO-61) (PRO) 4F-VATI(A= ASSL)HP-D I00-00'ELF-V.e RIM OF CATCqEA'�])� E)0--�TING &PNb�"A 99.6 16L C C 10, .0 'o'-o AvF-kA&& D BASE E I-E v 101 101.5 IZZD D E MAXIMQM Ey,j6TI N 45 ', F, A t) "G 99.7 M A)(/M 21114 a (,F- VATIobi 125.45 CuF-�IT A WsO N ao b tl-- DA-Tc- C3-5 /I+ /ao o Abbkl: 5S : ia?oc) AyC WFST- e-bMoMDS WA 1�802(o ENVELOPE- C61�- E L C--N/ :: 0)1). (o A (p96) H 6MVE-Lol-C CW e (pro) 'N' HEIGHT CERTIFICATE SCALE: NITS ISLO& C, E-LEV = 101.0 7:7 X - PRO I F-,iD/--C- LINE, -Tot,.: FS(6.9 (125.35) MID-pT8LD&J,.Nva> hl D Et-e v --- a(a? .9 FF ECEVAT101,I PUT T6f,.i(-ALL MID -PT 9LL)6 ENVLP Em\jELopL Cop,>. ekev F F-LF_\/ 101-g Q!!5 MIN f 13GN(-14 MAPK= ToP k^ ifATC-N-MIN FLEW= BTSUIZVEYS INC I -AND SURVEYING SURVICES 12415 9,111 DRIVE SE, VA"FIR FTT. WASHING'I'M 98208 206-601-1810 Flf-"' 26-239SO99 PR014-'.SS10NAL L1CFNSI:4 37i34 RESUB MAY 16 2019 a u I LD I N Glr.-R-.IM E N-1 40 West Main Street Lehi, UT 84043 Mce@tickdesigngroup.com 801-234-0445 0 Copyigh' 201 8 Ti,k Desip Group, LLC. All Righu Re—d IN pl..,—d "d. Pit— —dhith� d, INI A.th.d.fi.. Di..16.- "I S­—A, b...hi i0-6, --t" - .""t I— T'""I"t d.—.­ it i� _dW. C.—I-0--n—I.11 t.—Ply.ifli I D.C. A.--1 Ri&nIi.1 C.dt). I.-thli., PERMIT SET - REV 04 I-H—C 5/14/2019 5/14/2019 4 COLBYDALLEY 17 CRY STEVE TIEK SITE DETAILS A-011 WCIN= MAP (j t I S' I �31 !�'A' to United States Postal Senjice Pori Animal Hospital Homeowner: Alison & James Pope 18209 76th Ave W. Edmonds, WA 98026 Architectural Designer: Tiek Design Group 40 West Main Street Lehi, UT 84043 801-234-0445 office@tiekdesigngroup.com Structural Engineer: Iridium. AE 635 W 5300 S, Suite 203 Murray, UT 84123 801-974-5101 ............. May 14, 2019 PERMIT SET - REV 04 PROJECT ffNFORMATION A-000 Sheet Index COVER A-010 SITE PLAN A-011 SITE DETAILS A-101A EX MAIN FLOOR PLAN A-101B MAIN FLOOR PLAN A-101C MAIN FLOOR DIMENSION PLAN A-102A EX SECOND FLOOR PLAN A-102B SECOND FLOOR PLAN A-102C SECOND FLOOR DIMENSION PLAN A-103A EX ROOF PLAN A-103B ROOFPLAN A-200 EXTERIOR 3D VIEWS A-210 FRONT ELEVATION A-211 EAST ELEVATION A-212 REAR ELEVATION A-213 WEST ELEVATION A-500 DETAILS A-501 DETAILS A-600 SCHEDULES E-101 MAIN FLOOR ELECTRICAL E-102 SECOND FLOOR ELECTRICAL S-000 STRUCTURAL NOTES S-001 STRUCTURAL NOTES S-100 FOOTING & FOUNDATION PLAN S-101 MAIN FLOOR FRAMING PLAN S-102 SECOND FLOOR FRAMING PLAN S-103 ROOF FRAMING PLAN S-104 SHEAR WALL PLANS S-500 STRUCTURAL DETAILS -FAPPROVO I-571D, �, APPROUED PLAMS TOM 9E 00 Im i. City 6f EdmoA T) ALL WORK SUBJECT TO FIELD INSPECTION FOR C DE COMPLIANCE 0 a CITY OF EDMONDS BUILDPIINP. DEPARTMENT ADDRESS d1*00, IRD'Y1040 , I OWNER APPROVED DATE: BLDG. OFFICIAL: PERMITINUMBER 11 st-o� L--- Square Footage Table EXISTING MAIN FLOOR 1,296 SF MAIN FLOOR ADDITION 244 SF NEW COVERED PORCH 391 SF EXISTING GARAGE 457 SF NEW GARAGE ADDITION 121 SF EXISTING SECOND FLOOR 1,066 SF SECOND FLOOR ADDITION 733 SF TOTALEXISTING 2,819 SF TOTALADDITION 1,098 SF TOTAL FINISHED WEATED) 3,419 SF 'SQUARXpOOTAGESAPEMASUTLEEMMEX—ROPWALLS Deferred Submittals I . ROOF TRUSS DETAILS 2. GAS PIPING SCHEMATIC 3. MANUAL J & D CTV 4. FACTORY-BUELT FIREPLACE PRODUCT INFORMATION 40 Wml Mamn "Tel Lehi, "T.4.43 '��Eir ffice@tiek Es'.IE'.c.. 801-234-0445 0 Copyright 2018 TI& DI.igo Gro.p, I Rigl R--d wfl4h P,;. iI I. b...—ly b, It. CUM �WI N.1, L.1 I, JoU i, 0, 7NIlk Thk MItp G-p f,, �.tho, Tilk-t,I IIIIbiHtyf.'-- &Ii. Wq'Ey N., I., —h`­ I. Eh P" W. E--ft �Hl bI M& hfl.� ­rIply �j,h th A.C. (111—ti—I C.M. 0 0., 00 0" c') % z 0 00 PERMIT SET - REV 04 PLAN Sff DATE 5/14/2019 SHEETREVISED REv 5/14/2019 4 COLBY DALLEY rE TIEK COVER RESUB MAY 16 2019 GENERAL BUILDING CODE REQUIREMENTS 2015 IRC (AS AMENDED) SINGLE FAMILY RESIDENTIAL CONSTRUCTION GENERAL INFORMATION: The following list was put together with the intent of surrossurrizing some of the general requirements for the construction of single family dwelling and townhouse conatruction offlime stories or less. The following information has been compiled from the 2015 International Residential Code and The National Electrical Code. The wording is not the actual wording from the code and is not intended to indicate my changes to the code. The actual code should be ad for all ofthe closer wording, details, and requirements. All new construction to comply with the Washington State Energy Code. SITE PLAN: 1. BUILDING LOCATION. Building Location must comply with all regulations ofthe city ordinances. 2. FIRE PROTECTION. Buildings closer than 5 ft. to property line shall be of 1-hr construction without doors or windows. 3. EAVES. Eaves, overhangs and Injections cannot be less thria 2 ft. from the property line and mat be of 1-hr. lfwithin 3fi. ofthe property line. R302.1. 4. FIREWALL. Parapet or special roofoonstruction my be required on common walls for townhouses. See R302 for requirements. 5. EASEMENTS. Buildings cannot be located on my easements or right ofways. 6. SITE DRAINAGE. Ground slopes my not exceed 2 units horizontal to 1 unit vertical unless retained in an approved minister. Appendix 12015 IBC. 7. FOOTINGS. Footings of structure located adjacent to slopes steeper than 3 smits horizontal to I unit vertical shall be set back from the slope at least 1/3 the height of the slope if at the top, and % the height of the slope if at the bottom of the slope. R403.1.7. 8. GRADING. Site shall be graded such that the ground slopes away from the foundation at least 6" in the first 10' of the foundation. R401.3. 9. RETAINING WALLS. Any retaining wall over 4 feet in height from the bottom of the footing to the top of the wall must be an approved design with ongineer's details included. R404.4. 10. CUTS & FILLS. Cuts cor fills are not permitted within 2 feet ofthe property line. Appendix 120 15 IBC. 11. ROOF RUNOFF. Roof russoff shall be collected and discharged wall outside of the backfill limits, and at least 10' firm the structure or as per soils report recommersdations. 12. DRIVEWAYS. Driveways shall have an all-weather driving surface. A driveway serving as an egress path shall not slope more than I unit vertical to 8 units horizontal. Such driveways exceeding I unit vertical to 12 units horizontal must have a handrail. 13. SOILS REPORT. If required by the building department each lot shall have a soils report from a State Licensed Engineer after the hole is dug, the report and recommendations ft= the engineer must be on site at the time of the footing inspection, 14. WATER METER. Water meters cannot be located in driveways, approaches, sidewalks, or similar wells. 15. FLOOD AREAS. Homes located in potential flood areas will be required to have elevation certificates prior to and after completion ofoonstructims, R106.1 .4. 16. ADDRESS. Addresses shall be installed which are plainly visible and legible from the street. Numbers shall be a minimum ol`4�'Idgh with a minim= stroke width ofW'. R319. ARCHITECTURAL BUILDING PLANNING: I . EXTERIOR WALLS AND OPENINGS: Fire separation distance from property lines R302. 1. If two family dwelling m townhouse, provide a wan section showing fire separation. Note to openings or penetrations through party wall. 2. HABITABLE ROOMS AND BAT14ROOMS: 8% ofama in glazing. 4% in openings. 3 sq. ft. window in bathroom or an exhaust fan. R303.1 and R303.3. 3. BACKERBOARD FOR WALL TILES: Provide fliber-cernely, fiber -mat reinforced cement, or glass mat gypsum board backer board for wall tile in tub and shower sureas, to a height not less than 6 feet above the finish floor. R702A.2 & R307.2 4. MINIMUM AREA AND HEIGHTS: (1) 120 sq. ft. in bedrooms. 7 ft. min. ceiling height, sloped to 5 ft. min. R304.1 Dirractision all plans, state the us. of all filture rooms on the plans. 5. GLAZING IN HAZARDOUS LOCATIONS: Tab area less than 60" above the drain, showers, within 24�'ofdoors, within 18" ofa floor, less than 6(I'above a stairway, in within 36" ofstairway or landing. Ir ifgaardrail is provided. R308.4 Windows werse, than 72" above grade and the opening is 2Vr less from the floor requires a guard. R613 6. GARAGE SEPARATION FROM DWELLING: I- the sceidence and attics min. Y." gypsum board, applied to the garage side. Firms all habitable mom above garage anin. 5/8" gypsum Type ")C'gyperum board to the ceiling side. Doom leading from dwellings to the garage shall be 1-3/8" thick wild cow or 20 minute rated door. R302.5 & R302.6 7. EMERGENCY ESCAPE AND RESCUE OPENINGS. Finished sill 4�V'maximm above floor in every bedirom, 5.7 sq. ft. ofopen area or 5 sq. It. iflocated below grade. Sill must be within 44" offlom. 2Y'redin. width, 24�'mfis. height. Dimension all windows and provide description (slider, single hung, etc.) R310 9. WINDOW WELLS AND LADDERS: 9 sq. ft. min area, 36" projection flown window. Ifdeeper than 44" the window wall shall be equipped with approved permanently affixed ladder or steps. IBC 1030.5 9. EXIT DOORS AND HALLWAYS: One 32" door width when in the open position door is required, 36" min. width for hallways. R311.2 and R311.6 10. LANDINGS AT DOORS AND STAIRWAYS: 36" min. each side of exterior doom, top and bottom of stairway, unless door does not swing over top of stairs. P311.3 and R311.7.5. 11. STAIRWAY 36" min. width, 8" Essex rise and 9" min. tread, a min. headroom of6'- 8'above tread straing. Handrail at 3411 to 38" and 1114" to T'in diameter. R311.7 and State Amendment. 12. GUARDRAIL: At floors, stairs, or balconies mom than 30" above grade, 36'min. height and a 4�'spherta shall not pass through openings. R312.1 & R312.3 13, UNDER -STAIR PROTECTION: Provide V," gypsum bond at walls, under stair surface, and my soffits ofenclosed accessible space under stair R302.7 14. MOISTURE VAPOR RETARDER: On the interior side of framed walls. R601.3 15. LUMBER PROTECTION AGAINST DECAY: Treated wood or redwood on concrete. 18" min. under floorjoist, 12" min. under fimr berems to unfirdshed grade, &'min. from grade to framing or siding. R317.1 16. UNDER FLOOR VENTILATION: I sq. ft. to 150 sq. ft. or I sq. ft. to 1500 sq. ft. with vapor retarder. R408.2 Ventilation openings shall be within 3 feet ofewh conew ofthe building. R408.2 17. CP AWLACCESS: Min. of I8?'x 24" R408.4 Crawl spaces containing appliances Min. 3WX 22", not more than 20'from the appliance. M1305.1.4 18. ATTIC VENTILATION: Venting of I sq. ft. for every 150 sq. ft. ofteres. to be ventilated R806.2 Provide insulation baffles to maintain a 1" air space between insulation and foot sheathing. R806.3 For Un-vented attic assembles comply with R806.4 19, ATTIC ACCESS: In attics that exceed 30 sq. ft. or 30" in height, a min. of`22" x 30" access opening shall be provided. R807.1 20. ROOF SLOPES and DRAINAGE: No shingles below a 2.12 slope. For mofs with 2:12 to a 4:12 slope two layers ofundearlayment required. For slopes greater than 4:12 single layer required. R905.2.2 21. ICE DAM PROTECTION: In areas where ice forms along the ctwes, 2 layers ofunderlaymerat c�nwd together, or a self -adhering polymer modified bitumen sheet to extend 2,V'pwt the heated edge ofthe exterior wall is required. R905.2.7.1 22. CHIMNEY TERMINATION: 2'higher than my portion ofthe building within 10'and 3'mininum above highest point the chimney passes through the roof R1003.9 23. FACTORY BUILT CHIMNEYS AND FIREPLACES: Listed and labeled and installed according to mmufwtwers'instructions. R1005. 24. FIREPLACE HEARTHS: 16" in front and 8" beyond each side ofa firebox opening less than 6 sq. ft. lf6'is greater, then 20" in front and 12" each side is required. R1001.9 and R1001.10 25. NATURAL LIGHT & VENTILATION: All habitable rooms shall be provided with aggregate -gluing wan of not less than eight percent (8%) offlue floor area of such moms, except for rooms which have artificial light capable of average illumination of 6 fisot-candles at a height of 30" above floor level. An adjoining room my be considered under certain conditions of R303. 1. 1. Ventilation shall be provided through source specific and whole house ventilation system designed and installed as specified in Sections M 1597 and M1508. Sao Items 113-119. IRIC Section R303.1 and R303.2. 26. WINDOW AND DOOR PLACEMENT. As noted on the plans, the window and door placements wed to be reviewed by the owner and contractor prior to installation to comm proper placement; center of room, exterior alignment, or other aesthetic considerations. This is especially important where changes or alterations are made to exterior and/or interior layouts, ENERGY CONSERVATION: 1. INSULATION VALUES: Provide insulation values per the prescriptive requirements offlue 2015 Washington State Energy Code. R-19 In walls, R-38 in Ceiling, R-30 for flows over unconditioned space. 2. ENERGY REPORT. Ifthe prescriptive requirements are not used a passing energy study (ReaCheck) is required per the 2015 International Energy Conservation Code. MECHANICAL: ALL MECHANICAL INSTALLATIONS SHALL COMPLY WITH THE 2016 IRC & IFOC I . REQUIRED HEATING: Heating equipment to maintain 68 degrees R303.8. Provide beat load calculations per m�al I R1401.3, and ductwork design information per Mossmal D R1601.1 2. FURNACE CLEARANCE ANDACCESS: A required 3" min. on the side and ran, 12" wider than fitmace. 30" in front offirmasee, or G'miss. ifa door in front. 30" x 3W'access platform with light for servicing. M1205 3. ELEVATION OF COMBUSTION SOURCE: All gas appliances in a garage to be elevated 18" min above flom M1207.3 4. APPLIANCE PROTECTION: Gas appliances located in a garage or carport are to be protected from vehicle impact. M1307.3.1. 5. CONDENSATE DISPOSAL: Condensate from all cooling coils or evaporators shall drain to be approved location. When damage to the building can occur provide a second drain system, M1411.3 �Vid. ..crobstricus m- 1. appliances in accordance with G2407. Combustion air shall not be taken from a sleeping mom bathroom, or toilet poom, or where flammable vapors are present. 7. WATER HEATERS: Show the location of all water heaters. If located on a wood floor provide a drainage pan. Note the use of a pressure mfiafvalve and seismic riestraints. M2005. Provide thermal expansion control. P2903.4 8. BTU'S: Provide the BTUs of all gas appliances being used in the home, Le.: furnace, water heater, dryer, kitchen stove and oven, outside BBQ, etc. 9. GAS LINE SCHEMATIC: Using the above BTU's provide a gas Line schematic for the home showing all lengths and sizes of pipe being used, Note total BTUs for the demand, and what the longest overall length is. G2413 and Chapter 4 of IFGC 10. CLOTHES DRYER VENT: 33'mmimum length M I 502.4A. I and State Amendment. 5'roduction for each 90 degree, 2.5" reduction for each 45 degree bends Table MI 502.4.4. 1. Torroination is Yfforn my opening. MI 502.3 11. EXHAUST VENT TERMINATIONS: 4'below or to the side, and I'above doors and windows. 12" min. above finished grade. M1804.2.6 12. SHOWER SIZE AND DOOR: 90D sq. inches and 00"in diameter, 7W'tall above the shower drain. Hinged door is required to wing oubviord. P2708. 1. The shower comportment access and egress opening shall have a min. unobstructed finished width of 22". P2708. 1.1 1 3 ' ICBO Approved Direct vent flounce. install per manufacturer instructions 14. Clothes Dryer Vent Mm length 35' or Manufacturers Recommendation. PLUMBING - ALL PLUMBING INSTALLATIONS SHALL COMPLY WITH 2016 IRC I . CLEARANCES FOR PLUMBING FIXTURES: 2,17'in front of shower, 30" width for the water closet, 2 1" in front of cabinets Bud water closet. R307 2. WHIRLPOOL BATHTUB ACCESS PANEL: Show die location for access to the motor Show a GFCl outlet for the motor. P2720 3 * HOSE BIB CONNECTIONS: Am to be equipped with an annospherio or pressure type vacurms breasker. P2903. 10 4. MAXIMUM FLOW RATES: Lavatory or sink faucet is 2.2 GPM, showorhead is 2.5 GPM, and water closets are 1.6 GPM. P2903.2 5 * LOCAL CODES: The plumbing system shall be installed in strict accordance with local and state plumbing codes. 6. WARRANTY. The plumbing contractor shall be responsible for the complete plumbing system installation and shall provide a one (1) yew parts and labor �ty 7. EXISTING UTILITIES: Verify the locations ofmisting waste and water utilities and make the necessary connections as required. S. EXISTING CONDITIONS: Visit thejobsite prior to bidding the project to become frandiar with the misting conditions and my interferences. 9. FEES AND PERMITS: It is the owner/contrachres responsibility to pay all fees and permits relating to the plumbing system installation, including utility connection fees, water preter, and underground gas line. 10. GOVERNING AUTHORITIES: Coordinate the installation and comply with the requirements ofthe governing authorities havingjurierfictio. for this project. 11. TESTING: All plumbing shall be left uncovered and unconcealed until it has beerl tested or approved. The plumbing contractor shall employ and pay for services ofa qualified independent organization to perform testing, adhisting and balancing fthe plumbing systems, as required. 12. GAS OUTLET., Every gas outlet shall have an individual shut-offvalve. The shut-offvalve shall be in the same mom as the appliance served, outside the firebox and within 6-0" ofthe appliance sewed. 13. POTABLE HOT WATER: All potable hot water systems shall be provided with a means ofcontrol for thermal expansion of the water This may be an expansion tank or other approved mechanism or presence release or control. 14. WATER PIPING OR DRAINAGE TRAPS: None shall be placed in walls which ara re -exposed to outside air. 1 5. HOSE BIBS: Shall be protected from freezing and have backfiow preventions devices provided. 16. WATER CLOSETS (TOILETS): Shall have a maximarem consumption of 1.6 gallons per final. 17. SHOWERHEADS: Shall have a maximum consumption of2.5 gallons per minute. 19. SHOWERAND TUB MIXING VALVES: Shall have balanced pressure or thermostatic valves, or valves that can be field adjusted in neordaw. with the nournsfacturees instructions to a maximum hot water setting pf 120 degrees. 19. PLUMBING VENTS: Shall terminate at least T-0" above or 101-011 away from any operable window or air intake opening. 20. CONCEALED SLIP JOINT FIXTURE CONNECTIONS: Shall be provided with an access panel to the utility one, which has a minimum dimension of 12". the "c"s panel is not required when fliejoints re made by screwing, soldering or solvent cementing to make solid connection. 21. EXHAUSTAND DRYER DUCTS: Shall not exceed 15 feet and two (2) 90 degree bends 22. ANTI -SCALD DEVICES: To be installed for all faucets, tub fillers, and showeirlseads. 23. WATER HEATER: ICBO Approved direct vent Water Heater. Include pressure release valve. Install per manufasituress recommendation. To be fitted with hurricane straps located within the top and bottom third of the tank. 24. WASHER PAN: Provide overflow washer pan; to be connected to a drain line and provided a drain trap. FIRE PROTECTION & CO2 ALARMS: 1. SMOKE DETECTORS: Inside each.l..ping romen, outside each separate sleeping arrained each additional story including basements. All detectors to be interconnected, hardwired and listed and labeled. R314 2. CARBON MONOXIDE ALARMS: For new construction detectors shall be installed on cach habitable level ofthe home that has fuel burning appliances or an attached garage. R315.1 as Amended by the State ofUtah ELECTRICAL: ALL ELECTRICAL INSTALLATIONS SHALL COMPLY WITH THE 2016 IRC & 2017 NEC 1. ELECTRICAL SERVICE PANEL: Show the location ofthis sub panel. 30" clearance required side -to -side, 36" in front of panel, and 6'-6" in height from floor. E3405. 2. ELECTRICAL OUTLETS: Shall be installed in finished habitable moms so that oil walls, railings, and fixed wall panels which we 2 feet or mom in length shall baw electrical receptacles spaced within 6-10" ofall openings and not mom than IT-0" apart. Provide outlets in walls, counters, islands, flows, bathrooms, laundry ments, basement, garage, hallways, and mechanical mom. An outlet is required for every 12' offinialied wall, I for a kitchen island, every 4'ofcoamer tops, and a min. of I in the garage and unfinished basement. Kitchen countertops, shall have small appliance branch circuit electrical outlets on all counters that ism 12-1 cor wider spaced along the center line of the counter top within T-O" ofall edges and no more than 4'-0" apart. All island and peninsula counters shall have at Istost one such receptacle that is not pined under an overhang in excess ofO'-6". E3901 3. ARC FAULT PROTECTIONS: All 120-volt, single phase 12-20 map branch circuits in dwelling wit bedrooms shall bearic fault protected. E3902.11 as Amended by the State ofUtah. 4. GFCI OUTLETS: All outlets on the exterior ofthe home, all outlets in the garage, bathrooms, within 6 feet ofany sink in crawl spaces, laundry room, kitchen counters, a minim= of I outlet in an unfinished basement, and mechanical rooms we to be GPCI protected. Exterior GFCI outlets to have waterproofcover. E3902 S. INTERIORAND EXTERIOR LIGHTING: One wall -itch controlled Light in ever habitable in= and bathroom. One wall switch controlled light in hallways, stairways, attached garages, and detached garages with electrical power. One wall switch controlled light to provide illumination on the mterior side ofdoors One light required in attics, crawl spaces, utility moms, and basements. 6. RECEPTACLES AND LIGHTING IN DAMP AND WET LOCATIONS: Wicetherproofcovers, for exterior outlets =it lighting to be listed for wet or damp locations. E3905.12 7. LIGHT FIXTURES IN CLOSETS: Surface mounted ineardeseent fixtures to have 12" min. between the fixtures and any storage. Surface mounted fluorescent fixtures to have 6" min. between fixtures and any storage. E4003.12 8. OUTLET BOXES: Boxes at luminaries or Imp holder boxes am required to be able to support a minim= (50 lbs.) or less. A luminaire that weights =a than (50 the.) most be listed for the additional weight to be supported. E3905.7 9. OUTLETS INSTALLED IN GARAGES: Shall be installed at minim= of 18" above the finish floor. IMC 3D4.3 10. ELECTRICAL DRAWINGS: am schematic in nature and along with the specifications set the basis for the scope ofwork. The electrical contractor shall be responsible for all the necessary item to make a complete and functioning electrical installation, including all permits and related costs. The electrical contractor shall be responsible to provide all electrical equipment and systems noted on the drawings, all as per the requirements ofcity or county entities and the national electric code. 11. EXISTING ELECTRICAL: To be evaluated for code compliance. Electrical contractor shall verify schematic with homeowner to confirm misting vs new fixtures. 12. BRANCH CIRCUITS: All branch chicuits terminating in panels to terminate with copper conductors. 13. ELECTRICAL CONDUCTOR: Shall comply with N.E.C. Article 310, Table 310.16, Note 8. All grounds and conductors to be copper with THW insulation. 14. CONDUITS: Size all conduits in accordance with the National Electric Code with no more than 40% fill. 15. EXHAUST FANS: Bathroom exhaust fims shall provide 5 changes of air par how. Locatfors specified on drawings. 16. BATHROOM RECEPTACLE OUTLETS: Shall be supplied by a dedicated 20�wsqs circuit. 17. ELECTRICIAN: To review & confirm all pliseement ofoutlets, switches, and fixtures with homeowner. ABBREVIATIONS: AFF -ABOVE FINISHED FLOOR OPP-OPPOS[TE AW - SINGLE AWNING PT - PASS -THROUGH DC - DOU13LE CASEMENT RER - REFRIGERATOR DH - DOU13LE HUNG R.O. - ROUGH OPENING D.W. - DISH WASHER ROW - RIGHT OF WAY E.G. - EXISTING GRADE RS - RIGHT SLIDING EX. - EXISTING SC - SINGLE CASEMENT FA - DOUBLE AWNING SH - SINGLE HUNG F.G. - FINISH GRADE SIM - SIMILAR FH - DOUBLE HOPPER S.O.G. - SLAB ON GRADE FRZ. - FREEZER TA-TRIPLEAWNING FX - FIXED GLASS TC - TRIPLE CASEMENT GL-GLASSLOUVERED T.F. - TOP OF FOUNDATION HO - SINGLE HOPPER TH - TRIPLE HOPPER LS - LEFT SLIDING TS - TRIPLE SLIDING LV-LOUVERED TYP - TYPICAL MU - MULLED UNIT VEST. - VEST113ULE OHP - OVERHEAD POWER VIF - VERIFY IN FIELD Table 406.2 Enerav Credits (2015 Cndpl cop-nole DESCRIPTION CREDIT�S) Estilinated Cost 31,7- 111611 EFFICIFNCY 11VAC EQUIP101:NT 3b: Air-sourve local pultip v% fill minimum I ISIT ol'9.0 To quality to claim this credit, file building pennit drawings shall specify the oplion heingsclected and shall specify the healing equipluctu, type pu(I lite Illillinnoll equipment efliciency. Sh EFFICIENT WATER 1111ATING 3b: [0 Water huating sysicul shall include tine ofthe f6flowing; Gas. propaw (It tul water heater with a minimum FF of0.74 or Water heatter li.ted by is undsowet: beat punrit meeting oil. equi.numl, ofoplion le. or for R-:!occuPalIcY. a central flea' Install, %valet heater with -.in EF greater [flail 2.0 thal wituldsupply DI1W loall lite units through a central %valet looli insidated with R-8 ulininunil pipc insuliction. To clualil� to claim this credit, the building permit drawings shall specify the optun' being sciccicdandshall l,ccify lite water healer equipment typeand she minimum Equipment Efli,icnev. 40 West Main Street Lehi, UT 84043 office@tiekdesigngroup.wm 801-234-0445 0 Copyright 2018 Tick Dmip G-ip, LLC. All Right R,,sr,ed E-re I-- i, tt� ­Ifty.­k D.IV C-P. All righl- --d- ..y.111tcP1d.�ti.­h­h. E.t ­.ci� i, v.p_Iyp.hE,iW. Th-pi 0..Id..­­d, 4416­, ­i�d, v­11d, ­­d ffi­­ it thk..P1.r1�1.Thh pl. h 1--d W, I.- ralctlh�N..Add­­­�ff I, 11,W t1h, �Elt It6s. -.1 al., _h.ft Es-1-fir.: Tia Doig, G..p .= ­ "a 'y ­­ d.io- i�.V�ly ..Wcr - t.d ­f"i" 1, thi, IN. -1 tiett �fll b. ..d. . b­ .11 di-i-, i­E.�. ..d ­.� - ­va If. . ....... i�'i­ &c� ­ it m It, I.-p­ibility dlh� ­.fld�r tWify .1 ­11. if Ettill tpt-try dc,lp h ­ r­­­fld,*1­ A.11 ..kc it ­.­ .det,91- d.,i.g Etc- t. i,h ft I.R.C. (It-tiud 11.16.6.1 C.d,), IW,t �difi­, ­Pplkw, dt 't dtv c­­ 1. orify .11 di­mc & Wi.g it -diti- Ed,, t. ­­E­ PERMIT SET - REV 04 P­ ME -T 5/14/2019 it I.-T x1evners REV 1/4/2019 2 up -BY COLBY DALLEY CHEERED BY STEVE TIEK GENERAL NOTES RESUB MAY 16 2019 A-001 DEMOLITIONNOTES 1. EX 3050H I.n. EX. 3—H 7-- z: z z :: z =:: z 2: F==== > y EX. DECK EX. FAMILY —REMOVEBUMP-OUT WALLS TO BE DEMOLISHED LLL� ----- EX. DINING EX. KITCHEN EX. OFFICE 41� I A it F_; l.r:: z:: z --I I 41_ EX. GARAGE CLOSET'� X. 13ATH EX. EX. HALL EX. ENTRY TO BE DEMOLISHED EX. DECK z: zq ---- �A z: z: EXEM-13— L J MAIN FLOOR EXISTING PLAN SCALE: 1/4"= 1'.0" EX. LIVING EX. DECK 7­1 J__j 4� L ----- J 3-st, EX. 3050SI4 1. CHECK POWER AND WATER SHUT-OFF LOCATION PRIOR TO DEMOLITION 2. TAPE FILTERS OVERALL AIR GRILLES 3. NOTE LOCATION OF ALL ELECTRICAL WRUNG, PLUMBING, AND MECHANICAL PRIOR TO DEMOLITION 4. NOTE BEARING WALLS AND CREATE TEMPORARY SUPPORTS WHERE NECESSARY 5. DO NO DAMAGE To THE STRUCTURE OR FINISHES OF WALLS TO REMAIN 6. DISPOSAL OF ALL MATERIALS TO BE DONE ACCORDING To THE LAW 7. TIEK DESIGN GROUP IS NOT TO BE HELD RESPONSIBLE FOR THE PRESENCE OF ASBESTOS OR OTHER HAZARDOUS MATERIALS ON THE JOB SITE. SHOULD ANY OF THESE MATERIALS BE FOUND, ACTIONS SHOULD BE TAKEN TO REMOVE IT. 8. ALL PLUMBING, ELECTRICAL, AND MECHANICAL TO BE CAPPED AND/OR PROTECTED PRIOR TO AND DURING THE DEMOLITION AND CONSTRUCTION PROCESS UNTIL THE INSTALLATION OF COORDINATING UTILITIES. I WALLLEGEND I TO BE DEMOLISHED NEW WALLS I EXISTING TO REMAIN 40 West Main Street Lehi, UT 84043 office@tiekdasitingroup.corn 801-234-0445 0C.pydgh120l8 TiADmig.G—p, LLC. All Rights Re—d _V1. . P­W t.d,, —i L.t..d I, th. p.ptIty.17MA -11 ..1, All Iia. — --d -!Id, ­11td, E y b. �hi . ... .. i� t. It E;d ..Iy fb, th. CE_ —. Ad"""' .,&.r k Nwd it, tl,� Tftl� ­& C..00 Twk Dt0p G,.,p 1b, V tttt, Di.lai— Tmk 0-09- qmp 11.1tility f., t—I F-I-EIII, it, N,I 1�� �111 b, d— It i, th. .k ­­jbil ity a th� ...­ i id,, =ify­T.­rE­tr ppi ... tt.� d,tip i� —di "I'=2 ­2" tim" --I R C-1 d _i_ i. PERMIT SET - REV 04 SET -T. 5/14/2019 —aratiEfErE. 3/15/2019 3 COLBY'DALLEY .—E.DY STEVE TIEK EX MAIN FLOOR R EX, b AS N MAY 16 2019 BUILDING DEPARTMENT CITY OF EDMONDS A-101A m­ MAMH M300SH M­ (:�:) MAET FLOOR PLAN \1tv SCALE: 114" = 1'4' 00 uo-u I�j - U u 0 00 0 0 0 00 4(� WALLLEGEND TO BE DEMOLISHED NEW WALLS EXISTING TO REMAIN 5 �11 I � � I RESUB JUN 0 6 2019 S.-I.E.1 BUNI-0 . 1. E 0 Cpyight 2018 7' ek De,ig, Gmp, LLC. All Righ R-d p­ly­k­i,� d6'_­ �P­ly Mhibi,M. ­d, dil—I U­W,N—, Mll� B—, C­�d TfA -ig. G­ .Iibili y 1-M-fN-11 ­i., p.­ t. ..ply ja, C.­­ I. ­fy .11 FPE�RMIT SET - VREV 05 MMN FLOOR PLAN A-101B 17!3C) GFNFRAL NOTES, 1. ALL DIMENSIONS ARE TO FACE OF STUD WALL OR FACE OF CONCRETE, MASONRY OR ROUGH OPENING, UNLESS OTHERWISE NOTED. 2. DIMENSIONS TO EXISTING WALLS ARE TO FACE OF DRYWALL OR FINISHED SURFACE. 3. CONTRACTOR TO CONFIRM ALL WINDOW, DOOR AND OPENING LOCATIONS WITH OWNER. THESE ARE TO BE PLACED TAKING INTO ACCOUNT ALIGNMENT, CENTERS, FURNITURE, ETC. 40 t \ , k 39" WALL TYPES Qw) W1 - 2X4 WOOD FRAMED STUD WALL W2 - 2x6 WOOD FRAMED STUD WALL KITCHEN ------ L 217 Q 17 17 ]B!A�T�H LIVING F - �sQir 276 SQ FT 311- DINING 13SQFT 196 SQ n L NO= 2'J'— fill OFFICE BATH 175 SQ FT WALL LEGEND WLOSET 36 SQ 12SQFf 1. F =a*ss TO BE DEMOLISHED UP 3fV 5 HALL 279 SQ � �,. \\ F NEW WALLS —317 1� r I L—j EX CLOSET FAMILY 16 SQ FT k 246 SQ Fr EXISTING TO REMAIN 2-CAR GARAGE P.UP-!- 435 SQ cm—) 3'� IX lie F;;� PORCH -.305- - — — — — — — — — — — — — — — — — --- 392 SQ FT lw� ma. cn t! — — — — — — — — TD-14T — — — — — — — 27- MAIN FLOOR DIMENSION PLAN RESUB SCALE. 1/4— 1'-0" JUN 0 6 2019 -If"A".. CIOIE 40 West Main Sir" L.hi, UT 84043 offi�@tiekdesigngroup.cotn 801-234-0445 a copyight 201 8 Tiek D,,ig, Gmup, All Rights R--d pf �, . — � d j� 1h. P.NRy —A —9� G—P. All,�gbl . —d d di3OWWd. -md, fl—y ­— b-hn ... P.j..I. Thil pl.. il t. b. —d .1y R,1 th. Oi- —. —, Add— —, — i, WW j. a� TOk .1.6. ..- Timl -i� Mh.6—. Di,cl,imr: Ti—,ig—p --jimbis R--.1 —9. r-glily.—, ---W— m lbi� pl.. i n ft t. _ify Ifu-1 &�ip i, duft --ft. p.­ t. ­jy R.C. (RAN.1m. R�,i&.fl.l C dl), --difi—, —,p1w.b1...,. st C­"'-""­y di—i— & 'R� —ffi— "."o --"t— PERMIT SET - REV 05 MANsl-i—a 6/4/2019 6/4/20 DRAWN B, COLBY DALLEY STEVE TIEK MAIN FLOOR DIMENSION PLAN A- I IV' I C DEMOLITION NOTES ROOF TO BE SECOND FLOOR EXISTING PLAN SCALE: 1/4" = 1'-0" BE REMOVED ;;;: 1 �r ------------- i I ----------------- EX. LAUNDRY EX. BEDROOM EX. BEDROOM EX. 2668 EX. HALL L z z z:: �J^E Q. EX.CLOSET r— — — EX.CLOSET EX. BATH EX.CLOSET OPEN TO BELOW L— — — — — — EX. MASTER BATH 4'— it EX. MASTER BEDROOM EX. BEDROOM TO BE REMOVED 1. CHECK POWER AND WATER SHUT-OFF LOCATION PRIOR TO DEMOLITION 2. TAPE FILTERS OVER ALLAIR GRILLES 3. NOTE LOCATION OF ALL ELECTRICAL WIRING, PLUMBING, AND MECHANICAL PRIOR TO DEMOLITION 4. NOTE BEARING WALLS AND CREATE TEMPORARY SUPPORTS WHERE NECESSARY 5. DO NO DAMAGE TO THE STRUCTURE OR FINISHES OF WALLS TO REMAIN 6. DISPOSAL OF ALL MATERIALS TO BE DONE ACCORDING TO THE LAW 7. TIEK DESIGN GROUP IS NOT TO BE HELD RESPONSIBLE FOR T14E PRESENCE OF ASBESTOS OR OTHER HAZARDOUS MATERIALS ON THE JOB SITE. SHOULD ANY OF THESE MATERIALS BE FOUND, ACTIONS SHOULD BE TAKEN TO REMOVE IT. 8. ALL PLUMBING, ELECTRICAL, AND MECHANICAL TO BE CAPPED AND/OR PROTECTED PRIOR TO AND DURING THE DEMOLITION AND CONSTRUCTION PROCESS UNTIL THE INSTALLATION OF COORDINATING UTILITIES. WALL LEGEND TO BE DEMOLISHED NEW WALLS EXISTING TO REMAIN RESUB MAy 16 2019 SUjLDjNoGFMpMAFtTMENT CITY ED OgDS 40 West Main Street Lehi, UT 84043 ofrtce@tiekdesigngmup.com 801-234-0445 0 Copyrigh' 2018 Tiek Dmign Gmp, LLC. All Righm R,,md h­.th.fl.dh ,Xt� Bl­ ­­ Ti.k ­tp G—p .1h,, A'th"i.d... T.k E 72n ­p E_ffi� �ifl b� —d. i­ .11 di. —I.., dik.li­ —M—lim p—, t. -ply �hh R,�i&ntbl C.d,), �it, Cmt,,,t,, R,mly,11 li� —dill.n. pd., . PERMIT SET - REV 04 _ET.w 5/14/2019 EIIERTEEIIEE. ___7 DR— BY COLBYDALLEY c cKo' oy STEVE TIEK EX SECOND FLOOR PLAN A-102A SHEET KEY NOTES 1. BUILT-INS/CABINETS T I E K 2. SHOWER BENCH DESICN GROUP -- -f4f 2�"" __j 40 West Main Street Lehi, UT 84043 office@tiekdwigngroup.com 801-234-0445 a Cpyiight 2018 7nk D.ig. G..p, LLC. All Rigbts Rmmd Th.. p—p-- .p Typ.hibild. Th pl— �-ld- � —d, dahj=d, ­W. —iW, -- %, y T­ b-hi ... ��j- W, pl. h h. —,�d Wy fi., th. Clfi-'= hh-, Adh­ i, IWW h, tk Thh, h... TiA -i,h <6> thi, pbh �hl b. m.—I di.—i—, h,r—h.� & �46th—l—p bilRy,fih---ld,, d.ft� —"—w� P-- . ­ly BEDROOM LAUNDRY di— n 152 SQ Fr 62 SQ I'F WALLLEGEND r TO BE DEMOLISHED -wH (D ------ Q�) NEW WALLS \V BEDROOM Q7 108 SQ ff to BEDROOM 135 SQ Fr o -n- GE) HALL mmg EXISTING TO REMAIN 117SQFF 00 0 BATH EX 42N P� 50 SQ Fr F mm C/I <9> FT-'Q Z 0 BELOW BATH 0 OPEN T 29 SQ FT CLOSET 33 SQ FT ()o EK UE BEDROOM C) CE) 105 SQ FT BONU s 377 "Q 11 MASTEI BATH @E) LTERBDRM 3HOWE 59 F'T 175 sQ Fr 11 SQ Yr.. 5 EX2WW W� M�H PERMIT SET - REV 05 RJY '=Lf z. 7m.om D BEa�j( Q�OM WNDN <9> <9> <9> 6/4/2019 6/4/2019 DR— BY COLBY DALLEY @1 STEVE TIEK SECOND FLOOR PLAN SECOND FLOOR PLAN RESUB SCALE: 1/4" = V-0" JUN 0 6 2019 A-102B 13UILDING DEPPRTMENT CITYOFEDMONDS MCA&(�'� -� . 7 7" BATH 111-�--- -- - --] - IQ FT 7 r E;N: BONUS 377 SQ Fr CLOSET 31 !iQ FT mi �R' �HOWE MASTER BATH Q�i) z -DN— 59 SQ FT 17 SQ FT SECOND FLOOR DIMENSION PLAN SCALE: 114" = V-1)" LAUNDRY 62 SQ FT F— in- BEDROOM 108 SQ FT jI HALL 117 SQ Fr M2M 1- .. .. . .... ........ .... DO BEDROOM 105 SQ FT MASTERBDRM 175 SQ FT M2MM M.�SH M.2W$H GFNERAT,NOTES, 1. ALL DIMENSIONS ARE TO FACE OF STUD WALL OR FACE OF CONCRETE, MASONRY OR ROUGH OPENING, UNLESS OTHERWISE NOTED. 2. DIMENSIONS TO EXISTING WALLS ARE TO FACE OF DRYWALL OR FINISHED SURFACE. 3. CONTRACTOR TO CONFIRM ALL WINDOW, DOOR AND OPENING LOCATIONS WITH OWNER. THESE ARE TO BE PLACED TAKING INTO ACCOUNT ALIGNMENT, CENTERS, FURNITURE, ETC. WALL LEGEND TO BE DEMOLISHED NEWWALLS EXISTING TO REMAIN RESUB MAY 16 2019 BUILDIN =g'Ao CITY G Ell Mr OFE M NDS 41 Wesl=n .11me, fa.@ti.idesipgroup.c.. 801-234-0445 0 Copyi-ight 2018 T,,k Dc,ign Gmp, LLC. All Rightt; Ret—d P_ — P—.*, —1 — - 4 Ik ip G..p. Allflghl� . .—d t,W P.d-Z.ffil, lh� thM i.t�fli,,d i� ­11y P-billd. Th— pl— —d-t b� ft,ib�d, c.pi,d, —4d, --d 11,, � b-I ffii"— pl.i.il. nil pl.. il t. b..—.1y &I ffi� Cli- lh� N­ Md,­, t— — i, Jimid 1. tk nk BW,k. C—it Tkk DiAp G­ 1b, ­.tht, no llibilily P., P.— "."' 'i-i"i"'i"'I' It. E�ty.ftft �fll b� m& . i. —.11 di—n,ti—, id—tti... d n— — c. i­ it m th. W. ...ity — ... 11.,tIt—Olt—tit, d.1D, �,t _dW. -d&titi— d,,fi.g ­­oi., p ttt­.,pI­jtjt a,i R.C. (1-011111 R.tid-til C.&), Wttt �d�ti—, �' ipplit.bk ,d—,it,. C—t., t, 'i.—i— . WWI., th —difi..­I., 1. PERMIT SET - REV 04 PLAN i- I—E 5/14/2019 S—REVISED D— .1 COLBYDALLEY STEVE TIEK SECOND FLOOR DIMENSION PLAN A - 10`2 C EXISTING ROOF PLAN SCALE: 1/4" = V-0` DEMOLITION NOTES 1. CHECK POWER AND WATER SHUT-OFF LOCATION PRIOR TO DEMOLITION 2. TAPE FILTERS OVERALL AIR GRILLES 3. NOTE LOCATION OF ALL ELECTRICAL WIRING, PLUMBING, AND MECHANICAL PRIOR TO DEMOLITION 4. NOTE BEARING WALLS AND CREATE TEMPORARY SUPPORTS WHERE NECESSARY 5. DO NO DAMAGE TO THE STRUCTURE OR FINISHES OF WALLS TO REMAIN 6. DISPOSAL OF ALL MATERIALS TO BE DONE ACCORDING TO THE LAW 7. TIEK DESIGN GROUP IS NOT TO BE HELD RESPONSIBLE FOR THE PRESENCE OF ASBESTOS OR OTHER HAZARDOUS MATERIALS ON THE JOB SITE. SHOULD ANY OF THESE MATERIALS BE FOUND, ACTIONS SHOULD BE TAKEN TO REMOVE IT. 8. ALL PLUMBING, ELECTRICAL, AND MECHANICAL TO BE CAPPED AND/OR PROTECTED PRIOR TO AND DURING THE DEMOLITION AND CONSTRUCTION PROCESS UNTIL THE INSTALLATION OF COORDINATING UTILITIES. RESUB MAY 16 2019 BUILDING DEPARTMENT CITY OF EDMONDS T I E K'� DCSIGN GROUP —7 40 West Main Street Lehi, UT 84043 _,iekde'igngmup.com 801-234-0445 0 Copyright 2018 Tiek D,sig, Gm,p, LLE. All ltigh� R.S.—d F�- — d m 1. p­�ydTmkr,i�G.0 Allngh---l- rli�� —� N., Add-% il lilkd W ffi� T.ft .1��k. r.—I ll�k ­i� .­ DmW— T.lk -i� G.p . jj�bjljly f�, --1 —S. W.gd� .&.1 — d i. Wk P]. ff.ft �ill b. -& WI di—i—, d.i�g --m 1. ..p)y �iffi _PP �flfy .11 di.-- —di.l— pri., 1. --i— PERMIT SET - REV 04 PLAN SET DAT6 5/14/2019 SIMETIMVISED DRAWN BY COLBY DALLEY STEVE TIEK EX ROOF PLAN A-103A F-T1 r.1 I I NEW ROOF SECTION Fr -TTTF-1 F,-rFTT--1FT71 [I j If, F1 F1 I 1 71 -1 I F-11 F- fl f7F 3 112: 1 4 :12 4 :12 7: 4 :12 S1 ROOF PLAN SCALE: 1/4"=F-0" RESUB MAY 16 2019 BUILDINGD N ENT E S 40 West Main Street Lehi, UT 84043 Mc.@tiekdesigngroup.cm 801-234-0445 0 Copyright 2018 Tiek Design Grmp, LLC. All Rights Rasa—d TI,c. pl— — — - a 1. AlIfighl--d-d b-s ac� .. PI-j- ni,, ph. I, t, b� —d .,,ly ft th� C4.1 h,', N., A&—, W., WO I, fl�wd i. lh� Tift a I..k. n., li,,k I., ­ Mc.daslwc. Disclaimer: I... ,. II.billty ., --I ft"'. W�IdtY W.1 — cd —N,4— is IIII. pl.,, .1-, ff. r] b. . d— i_'.. d —Mi _Jiry .M C. (I—ai .1 R�sid..fid C.&s WsIt ON—, ppI k.b I� 11d., a I a. Cc—, W cify , I I . c,isi.9 IiI ... ,difi— H., . ---n. PERMIT SET - REV 04 I—N—AT. 5/14/2019 SHEETRIEVISED -v COLBY DALLEY CIIECKEDBY STEVE TIEK ROOFPLAN A-103B FRONT LEFT 3D VIEW SCALE:NTS BACK LEFT 3D VIEW SCALE: NTS FRONT RIGHT 3D VIEW SCALE: NTS (�7) BACK RIGHT 3D VIEW SCALE: NITS RESUB MY j 6 2019 40 Wes, MamS, .. I Lehi, ll404' ffi"@tiek 801-234-0445 0 Cpy,ight2018 TkkDipG—p, LLC. All Righft R--d P'V�'y lfff�k D.ip G..p. Ali r0h — --d- dmlTib.t,d, ­` —.1 —d I., Y ­— b.lthi� ... P.p. ni,1.-Wb—.d..1yffi,th. Ti,k D,6p Omp 2— i --1 W.ft — -"1— 1. i� ".. E', M-11 b� —d. t. i.�— .1i di—im, id.—E.. d ...... mi. i, j, lh. 1.1k .1p..Iibil.ty ftk -,Y ir d.il,, .—d. A.11 —k. .11 —.—� —dir-li— &H,,, p t. .Wly �iffi il" l.R.C. pp i— & �lllmg- —ditt— p�., 11 --oi— PERMIT SET - REV 04 PLAN SET DATE 5/14/2019 EHEETREvIsED DRA" BY COLBY DALLEY STEVE TIE EXTERIOR 3D VIEWS A-200 4-- 5 ag101,10i 01 Rim 111 R 1 11111 min 11. 111 -1 1 F-1 F1511 [11 FF11 F51 101=11 Fl=� ------ EXISTING FRONT ELEVATION SCALE: 1/4— V-0" IN minim 11111 Imil M! pq QW, HIM* 110-101MAHNIN-M-0 11,01 FRONT (S) ELEVATION SCALE: 1/4— V-0- maim a 010111111111111 NINE MINE 0 1-9 RESUB MAY 16 2019 BUILDING DEPARTMENT CITYOFEDMONDS 40 West Main Street Lehi, UT 84043 Mce@tiekdesigngmup.com 801-234-0445 0 Cpy,igh' 2018 Tkk M�ip G..p, LLC All Righa; R—d —0 All risl,. --d �t th!—� Thl, pl.� i, I b.--ly lb, lh� Add-,..W., L.tk i� Inod i. lk M,k D-p mWplty W., I. thi, pl.� I'll — 11 b, m...11 di —a., ll� MI. mp Maly fth—bild� d,�iq —­t­ ­— W,..,Iy RC. al�i&-1 PERMIT SET — REV 04 PLANSETDATH 5/14/2019 sa—EvIsm �ry 511 4 DRA" .1 COLBY DALLEY Cl I—E. BY STEVE TIEK FRONT ELEVATION A-2 10 EXISTING EAST ELEVATION SCALE: 1/4" = V-0" I dmg�' RE,9UB MAY 16 2019 BUILDiNG DEPARTMENT CITY OF EDMONDS 40 West Main Street Lehi, UT 84043 ce@tiekdesigngmup'com 801-234-0445 0 Capyright 2018 Tisk Design Gnup, LLC. All Rights Res—ed ,I_ , " — P.— Ind. —I — Isd I, It. '."n' eg�k D IIEI G.. . All fl.Ns 'en, .p,-1yp.hibiWd. di�l hyi h b 1, t_ Cli—W'Nsee. --fi- _eisnem_ tyf,,11—I I=I -ig—ngHty dv.' . d- W-ftpl.. st". E� —.1idihernme, .I.. ed —I I. �.—. If.. I-, . -nm 'II .� it is th, 1.11 . p.libility Oth. W[ I—— d.HIE —­11.s ­, e, t.,ply �jffi R.C. —,IIW Cdt). Int�l Idis­, -pp ksb]. eIdII It Iin. C.ses­ I, ­Ify .11 ft-i— &ZinmE sil� .Idifi— H.- --- PERMIT SET - REV 04 1 PLAN SET DATE 5/14/2019 BIIEET BE-E. DTIA" BY COLBY DALLEY CHEMED BY STEVE TIEK EAST ELEVATION A-211 EXISTING FEAR ELEVATION SCALE: 1/4" = V-0" ItV 7- -D—, - Umm% "".' j.0 j— — Is I mini �'d — — — — — — — i L 7. . i� -- — — — — — — — — — — — — — — — — 17— 71-77-- - - - - - - - - - - - - - - - - - - - - - - -- -- - - - - - - - - - - - - - - - - - L --7 L — — — — 7 7� hi I ' . I -- , - I , - - - - - - - - - - - - - - - - - - 7:— W REAR (N) ELEVATION SCALE: 1/4" = P-0" 40 West Main St—t Lehi, UT 84043 frtce@tiekdesigogroup.com 801-234-0445 0 Copyright 2018 Tick Dmign Group, LLC. All Righ R—d ttl_ pl_ p—W.. Rd—Mm—di,th. W, IyMhibiWd.Th��.pl�llh,lid.tb�,,..��, p1j- TIli, p1l, i. W b,, l,d ,.1y �, th. CRIM N­ Add—­W., U4 b 16W i. "', Till. -.k. C.'.tTik D,dg,, 6­ fi,, ly Ith., &o'. W'd'y i. thi, pl.. ..d o.o, d . i t i � ffi . � . I b i ll i' Y f� "' &j`ii tr.11 ly .. -11 f bdh, r pp --M dl,ip i � —. --.r&ofld,,-- AA —k-11 —11, 'h:din.l'i ,' ,Ll'm —l—li- P.— 1. ­ly I.R.C. R-d,,rlml Cl,&), 1-tldffi—, _p"llolbT. dl, lt flo. C-r—, t. �,,dfy JZ di-11— . o,jltft l". —dilim, mr 1. PERMIT SET - REV 04 5/14/2019 COLBY DALLEY CH—D BY STEVE TIEK REAR ELEVATION 3 ' 'L , MAY R'T"MEIII A-212 40 West Main Street Lehi, 84043 @ d tiek group. 8 .2347 0445 01-23 .0445 0 Copyright 2018 Tiek Design Group, LLC. All Rights Resmod n—p) p-Inght--d- d, ns pl.i-, nil d.. h 1. b-1-1, lf� is lin,d Tia -ip Gddp .,a., . liiibilii, s,, --t dtfls� i-nily nW., t— _ -iW— i. n" ".. I'll �jll b i—. .11 di -di—, d— ..t. it i, 1h,, s.1— '11.ftht—A ild,, 1� ttil, — ff- il dht, .,I "nq is —didt.i— d.d., —ondam p.t— t. —ply i1h z � � '. (--i—1 --i.1 —t), 1.11A tditi—, ., ­ 1�.bl. t.&s a nit. C,­W, t. -dify .11 di—�i— & �,,idmg lil� 11,11H.t. pd., W EXISTING WEST ELEVATION SCALE: 1/4" = F-0" ... .............. 2 1 1-3/4" — — — — — — — — — — — — — — — — — F. PERMIT SET - REV 04 FTT —SETDAM 5/14/2019 SHEETBEVISED R11 DRA" BY COLBY DALLEY CIMCKEDBY STEVE TIEK WEST ELEVATION WEST ELEVATION 1\tv SCALE: 1/*'= V-0" RESUB MAY 16 2019 A-213 BUILDING DEPARTMENT CITYOFEDMONDS -2zLwQR-- -1SU1DQ&- BUILDING SECTION I SCALE: 3/8" = V-0" STAIR SECTION SCALE: 1/4— 1-41 m Goirip.s .6 Vr*eA- 2,cim xax- �z,t STAIR INTERIOR ELEVATION SCALE: 1/2— F-W' RESUB MAY 16 2019 40 West Main Strmt Lehi, UT 84043 ffice@tiekdesigngmup.com 801-234-0445 0 Copyright 2018 Tiek Design Group, LLC. All RighB, Rtolorvd Th_ pj_ —P—W..d. —.1—di— D��iio n-1. All rilghl . —d or ha...H�ofh dmoi—d­PiM­kd,..&.,,o Dha-i­ T.k-ip—p—. h. bill .1-1 l.d..Wr k� —'.' -m— .�t i� th� r.l� V.rlibifity dft.—HW, ... fforoh., &�" h .dW. C..t..-1o1dW.--h0 ..k. .11... —o.. P.— to —ply �hl, PERMIT SET - REV 04 —N—DAT6 5/14/2019 SHE—EVISED 5/14/2019 4 DRA" BY COLBYDALLEY STEVE TIEK BUILDING SECTIONS �' 111) TYPICAL INTERIOR MOUNTING HEIGHTS SCALE: 1/4" = F.0" (2) CORNER DETAIL \,�fV SCALE: 3­1�0" 2" 1 118" b p — SIDING BASE DETAIL 2 SCALE: 3" = V-0- ASPHALT SHINGLES ROOFING VAPOR BARRIER 7/16" ROOF SHEATHING BLOWN -IN ATTIC INSULATION OVERHANGING TRUSS STYLE "D" DRIP EDGE HALF ROUND GUTTER 2X6 SUB -FASCIA 5/4 x 6 PAINTED CONTINUOUS FASCIA VENTED SOFFIT 5/4 It 8 FRIEZE BOARD SIDING (PER ELEVATIONS) SIDING (PER ELEVATIONS) LAP WEATHER BARRIER OVER FLANGE AND SEALITAPE TO FLANGE CAULKING (ALL AROUND) PENETRATION (I.. EXHAUST FAN) SEAL AROUND PENETRATION USING MINIMALLY EXPANDING POLYURETHANE FOAM OR APPROVED CAULK BLOCKING rs'\ TYPICAL WALL PENETRATION DETAIL SCALE: 11/2" = 1'-W FLOOR JOIST (RE. STRUCTURAL) REINFORCED CONCRETE FOUNDATION (RE: STRUCTURAL) REINFORCED CONCRETE FOOTING (RE: STRUCTURAL) CRAWL SPACE 4." 4 4 .�A 7. 4 1/2' GYP BOARD (DRYWALL) BATT INSULATION PLYWOOD SHEATHING AIRWEATHER BARRIER WALL FINISH (PER ELEVATIONS) RIM JOIST DRIP PLATE J-BOLT W/ 3' WASHER TREATED SILL PLATE SILL GASKET SIDING BASE (SEE 2/A-50D) GRADE 40 West Main Street Lehi, UT 84043 office@tiekd�igngmup.com 801-234-0445 0 Cpyigh' 2018 Tik Dwig. G..p, LLC. All Right; Re—d ­M.-& N�ip 0., AINShN ­­­d ,zly P'hib!.. Th- pl— —ld- b� .­d, b.t thi, — p.j- Thi� pl.� il � b, ­d �Ily III ft Clx�t �W, N... Add ...... TRI� 81'k. ­­ Txk D,flp G­ RE, M Mh�� A.1b'." Dixl.i­ D'Ifg. Owup 11,bility �­­i d.,is.i­9rfty i. Em pl. E­ ­­11 b. — W i­ �11 di—d—, d­­­ ft i� lh� �.[� —p—IbUily fth, .—A.0ft, ­d.d d.6.9 P.." t. —Ply �iflh R.C. 0-9m I Rd&�IN Cd.). _Rdl�.bl' 1—t 0�. C,.R­ ­�fy,dj di.-- � 111fl.9 � —did.., pd., W 111.0m. �' . I � �' FIELTERFABRIC 11-111— CRUSHED ROCK OR COURSE GRAVEL (NO PERMIT SET - REV 04 IMES) LIT =11H ir 1=1 Ll -1 --1, 4"0 PERFORATED DRAINPIPE 1 1=1 11-111-1 =1 I 1=1 I El I I— FLANSETDATE 5/14/2019 1 la I M I El I I- SHEUREVISM REV El I EIJI I 1=1 I M. 3/15/2019 3 DR— BY COLBY DALLEY El IECKED BY STEVE TIEK DETAILS RESUS 6 2019 TYPICAL WALL SECTION m TYPICAL EAVE r4 MAY 1 EOTIME A-500 SCALE: I IIT' = I�V' \�A V SCALE: I 11r - F-0" B U "IDY"* 0 . .1E DS 95 6x6 SUB -POST BLOCKING (ONLY FOR COLUMN -WRAP) SLIP-m 10" PACIFIC ENDURA-LITE FIBERGLASS COLUMN, MON-TAPERED, SMOOTH FINISH TUSCAN BASE, CAPITAL & NECK TRIM OR COLUMN -WRAP 10"PACIFIC ENDURA-CRAFT COLUMN WRAP, NON -TAPERED, SMOOTH FINISH *TUSCAN BASE, CAPITAL & NECK TRIM COLUMN DETAM SCALE: 3"= F-0" ASPHALT SHINGLES ROOFING VAPOR BARRIER 7/16" ROOF SHEATHING STYLE "Do DRIP EDGE 2.8 EXPOSED RAFTER BEAMS SOFFIT 2.8 TRIM GABLE VENT 5/4 x 5 TRIM 4 3/4" x 4 3/4" CORBEL 5/4 x 8 TRIM SIDING (PER ELEVATIONS) GABLE VENT DETAIL SCALE: 1 1/2" = IW- r2'� COLUMN TOP SECTION \�� SCALE.3" = V-0" COLUMN BASE (&, PORCH DECK SCALE: 311 = V-0" WETAL ROOFING )GE "MR JS FASCIA WN SHAFT HAFT .UCTUPAL) UCTURAL) 3 (REF: STRUCTURAL) RESUS MAY 16 2019 13u,LD1N.GrU,F-,PWM'M'6ENT S 40 West Main Street Lehi, UT 84043 office@tiekdesigngroup.com 801-234-0445 0 Copyright 2018 Tick Design Cmup, LLC. All lZights Rc,c—d TI_Pl_ — r— . o-, -..I — - i� �),, _,ny �,TU .-11� n.. . All HENs "'on whds N­ Ad�,� scnV., U9 I, liord I. tIR TRIc SI.& C.—I MA D,orc G I,—, d.l.s inS.4y .V, =. .2i".1n.— lb is pl�. —difirli— d-,; .n000i,� p— t.—ply"i .h...R.C. -i—W C.d�), kov cdW., -,.ppft�.bl� .d.- slo. —­R, w ojfy sli di_11--s & 1.11n, A. —did— ,I., . —M...n. PERMIT SET - REV 04 P"NSETDATE 5/14/2019 SHEET REVISED rry 5/14/2019 4 COLBY DALLEY r- BY STEVE TIEK WINDOW SCINDULE ELEVATION MARK LABEL OTY WIDTH WEIGHT DESCRIPTION GLAZING TYPE wol 1468 2 16 80 FIXED GLASS - TEMPERED GLASS DOUBLE PANE WITH LOW-E W02 1534 1 17 40 SINGLE HUNG DOUBLE PANE WITH LOW-E W03 2250 2 26 60 SINGLE HUNG DOUBLE PANE WITH LOW-E W04 2840 2 32 48 SINGLE HUNG - TEMPERED GLASS DOUBLE PANE WITH LOW-E W05 EX. 3040 1 36 48 SINGLE HUNG DOUBLE PANE WITH LOW-E W06 3040 3 36 48 SINGLE HUNG DOUBLE PANE WITH LOW-E W07 30510 1 36 " 70 SINGLE HUNG - TEMPERED GLASS DOUBLE PANE WITH LOW-E W08 3250 1 38 " 60 SINGLE HUNG DOUBLE PANE WITH LOW-E W09 4040 1 48 " 48 SINGLE HUNG DOUBLE PANE WITH LOW-E wto 4040 1 48 " 48 SINGLE CASEMENT-HR DOUBLE PANE WITH LOW-E Wil 4040 2 48 " 48 LEFT SLIDING DOUBLE PANE WITH LOW-E U-VALUE: 0.30 OR LESS SHGC: 0.42 OR GREATER AIR LEAKAGE (AL): 0.30 OR LESS DOOR SCHEDULE ELEVATION MARK OTY LABEL WIDTH HEIGHT THICKNESS DESCRIPTION DOI 1 1868 20 801, 13/8" SINGLE HINGED D02 1 2268 26 80 " 13/8" SINGLE HINGED D03 4 2468 28 80 " 13/8" SINGLE HINGED D05 7 2668 30 801, 13/8" SINGLE HINGED D06 1 2868 32 801, 13/4" SINGLE HINGED - ENTRY D07 1 2868 32 80" 13/4" SINGLE HINGED W/ LITES - ENTRY D08 1 3068 36 80 " 13/4" SINGLE HINGED W/ LITES - ENTRY D09 1 2668 30 801, 13/8" SINGLE POCKET D10 1 3468 40 80 " 13/8" 4 DOOR BIFOLD DII 1 4068 48 901, 13/8" 4 DOOR BIFOLD D12 1 3668 42 80 " 13/8" DOUBLE SLIDER D13 1 5068 60 801, 13/8" DOUBLE SLIDER D14 1 16480 196 96 " 13/4" GARAGEDOOR - ALL GLASS IN DOORS TO BE TEMPERED RESUB MAI 16 2019 BUILJ)ING DEPAF(TMFNT rF OF EDMONDS 40 West Main Street Lehi UT 84043 office@tie�de igngroup.com 801-23`4-0445 0 C.py,igb' 2018 Twk D��ig. G..p, LLC. All Righv� R--d —d- Th— Clim—h ,It. Dr -B-ili b� ........ W'17' i2".. 1. -ily W"' ­1­72 'i"' j� 6.11 ..k. T1 I-- . P-11 t� —Ply th� I.B.C. (Bll—ti—1 Mid'i.1 C-), 1—t �d�ti­ ­B.bl, �.d,, l,1 0� " —ify a & .WimS il. —dili— pB., 1. PERMIT SET - REV 04 PLAN SET —E 5/14/2019 3/15/2019 3 D— BY COLBY DALLEY STEVE TIEK SCHEDULES al MAIN FLOOR ELECTRICAL PLAN SCALE: 114" = 1'4' \L OPEN TO ABOVE t�dF7 MINIIJEJ JG' X IF ELECTRICAL LEGEND SINGLE POLE SWITCH 3-WAY SWITCH 4-WAY SWITCH RECESSED CAN LIGHT (SIZE IN INCHES) RECESSED CAN EXHAUST FAN (MIN 50 CFM) CEILING MOUNTED LIGHT FLOOR MOUNTED LIGHT -0- PENDANT LIGHT d WALL MOUNTED LIGHT + UNDER CABINET LIGHT CEILING FAN 9 110v DUPLEX OUTLET -qP I 10v DUPLEX OUTLET W/ GFCI PROTECTION (r I IOV DUPLEXIUSB COMBO OUTLET 1 10v QUADPLEX OUTLET 220v OUTLET 1 10v FLOOR MOUNTED DUPLEX 1 10v CEILING MOUNTED DUPLEX 220v FLOOR MOUNTED OUTLET CABLEJACK SMOKE DETECTOR (I 10v INTERWIRED W/ BATTERY BACKUP) SMOKE DETECTOR/C0 DETECTOR COMBO (I 10v INTERWIRED W/ BATTERY BACKUP) DOOR BELL/PUSH BUTTON a, WALL MOUNTED SPEAKER & CEILING MOUNTED SPEAKER RFSUG tgy 16 20 11E But-1-M 10 .1 10T.-S", 40,�ea,UM;Dn S"reel hi T.4�43 office@tiei(;Ri9ngrB.'... 801-234-0445 0 Copyright 2018 Tiek Daign Group, LLC, All Rights Raaa-d -odc,lcd—I L.—d i� Ihc ia_oy._�kDc�jp_ �.,. A116,Ih. .. -cood d .­..,op.d..i.n.1ho llo--Ih�li�dil --ly Pwhibi- Th par'..' .1 -,—d, dima,cod, �.pled, —.4d, =W., c.d �r y I—. a.t thi� ... pos,�I. Thim pl, i� w b�—d..Iy k, ft CI an' Add— oV., — i� IM. I. r,� U1. c.y Disalaim,,: lw� MOP G—­— n. Ii.bilily mo.—I '�trc� a,tagnly ..d -mi— i. 1hil pi.n �q .�i �rh—l—p —�Jrrc.a— P.." w ...P Y -1, z I ..I p.amat,—I R,fld,ctj.1 'dRi.n, cr . ­1a.b 1� .&s at 0�. ��flfy .11 PERMIT SET - REV 04 1I.A. Sar DATEI 5/14/2019 SHEETREVISED 3/15/2019 3 DRAWN BY COLBY D LLEY CHECKED BY STEVE TIEK MAIN FLOOR ELECTRICAL E-101 (2) SECOND FLOOR ELECTRICAL PLAN \1tv SCALB:1/4" = V-0" ELECTRICAL LEGEND $ SINGLE POLE SWITCH $� 3-WAY SWITCH $4 4-WAY SWITCH 0 RECESSED CAN LIGHT (SIZE IN INCHES) 0 RECESSED CAN EXHAUST FAN (MIN 50 CFM) 3�� CEILING MOUNTED LIGHT 0 FLOOR MOUNTED LIGHT -0- PENDANT LIGHT t!l WALL MOUNTED LIGHT + UNDER CABINET LIGHT =w - CEILING FAN qp I 10v DUPLEX OUTLET _9 1 10v DUPLEX OUTLET W/ GFCI PROTECTION (r I 10v DUPLEXJUSB COMBO OUTLET qp 1 10v QUADPLEX OUTLET 220v OUTLET 1 10v FLOOR MOUNTED DUPLEX 1 10v CEILING MOUNTED DUPLEX 1220v FLOOR MOUNTED OUTLET CABLE JACK SMOKE DETECTOR (I 10v INTERWIRED W/ BATTERY BACKUP) SMOKE DETECTOR/CO DETECTOR COMBO (I 10v INTERWIRED W/ BATTERY BACKUP) DOOR BELL/PUSH BUTTON sp WALL MOUNTED SPEAKER 8 CEILING MOUNTED SPEAKER RESUS MAY 16 2019 BUILDING DEPARTMENT CrTYOFEDMONDS 40 West Main Street Lehi, UT ofrace@tiekdesi=p.com 801-234-0445 0 CopyTight 2018 Tick D,,sign Gmup, LLC. All Right, R--d P_ k ffi, .Y.— th,, th.. 1h, ftti,d it ­—lyp-bild T11t.p1—h1.1d.tb--td, �fit—h.'Nt­ Add-, L.1# k likId i. th� TRI. Bl.,k. C."Ott TA D,is,t 0 p s,, y .1h,, -26.fl— Disclumer: - Imbility d,ip 1.t,lty ��d m thi, ph. B­ .— �R' b. d— ..t., it i, ffi� �.it-p ibility dth� --ildt, 1� .1ify M1. if —, ppik—,, d,tis,, b --Atildt*—, A.11 ..it. .11 —t­ ftrim. --ti. p,.— t. ­1y h:d�ifi.t . .R.C. B.'_...1 R,fl&.tiM C.6), I.- �dftim, —p"i '— -t� .10.. --.r t. —ify .11 --i— & �.itftg —diti— pm, t. --dt— PERMIT SET - REV 04 seT -Ta 5/14/2019 sBIBT BrIls. 3/15/2019 3 D— BY COLBY DALLEY CIIICK108Y STEVE TIEK SECOND FLOOR ELECTRICAL E-102 ABBREVIATIONS & ACRONYMS A. P A. AMERICAN PLYWD ASSOC. JST JOiST(S) AlEOR ARCHIENG OF RECORD JT JOINT(S) AS ANCHOR BOLT ABV ABOVE K KIP, 1000 UBS ADDL ADDITIONAL KLF K P PER LINEAL FOOT AFF ABOVE FINISH(ED) FLOOR KSF S K:PS PER SQUARE FOOT AGGR AGGREGATE KSI KIPS PER SQUAREINCH ALT ALTERNATE ALUM ALUMINUM LAT LATERAL AMT AMOUNT LB(S) POUND(S) ANCH ANCHOR LID LOAD APPROX APPROXIMATE LEV LEVEL APRVD APPROVED LF LINEAL FOOTIFEET APVL APPROVAL LL LIVE LOAD ARCH ARCHITECT / ARCHITECTURE LLH LONG LEG HORIZONTAL ATCH ATTACH(ED) LLV LONG LEG VERTICAL AVG AVERAGE LT LIGHT LT WT I I L GHT WEIGHT SO BOARD LVIL LEVEL BHD BUCKHEAD LVIL LAMINATED VENEER LUMBER BL SOLLARD LWC LIGHTWEIGHTCONC BLDG BUILDING 13LKG BLOCKING MAS MASONRY BLW BELOW MAX MAXIMUM ELM BEAM MC MOMENT CONNECTION B.O. BOTTOM OF MECH MECHANICAL BOF BOTTOM OF FOOTING MEMB MEMBRANE BOT BOTTOM MEZZ MEZZANINE BRG BEARING MFD MANUFACTURED BRK BRICK MFR MANUFACTURER SSMT BASEMENT M:N M:NIMUM BTR BETTER MsC M SCELLANEOLIS BTWN BETWEEN MO MASONRY OPEN MTL MATERIAL/ METAL CANT CANTILEVER C-C CENTER TO CENTER NIA NOT APPLICABLE CG CENTER OF GRAVITY NF NEAR FACE CIP CAST IN PLACE NS NEAR SIDE/ NOWSHRINK CIR CIRCLE N-S NORTH -SOUTH ci CONSTR/ CONTROL JOINT Nic NOT IN CONTRACT Cip COMPLETE JT PENETRATION NTS NOT TO SCALE CL CENTERLINE CLG CEILING 0 ' C. ON CENTER CLR CLEAR 0 , F. OLISMS FACE CMU CONCRETE MASONRY UNIT OD OUTSIDE DIAMETER COL COLUMN OF OUTSIDE FACE CONC CONCRETE OPNG OPENING CONN CONNECTION OPP OPPOSITE CONST CONSTRUCTION O.H. OPPOSITE HAND CONT CONTINUE (CONTINUOUS) OSS ORIENTED STRAND BOARD CONTR CONTRACTOR OWST OPEN WEB STEEL JOIST CTR CENTER CU FT CUBIC FOOT (FEET) PARA PARALLEL CU IN CU INCH PC PRECAST CUYD �C CU: C YARD PCF POUNDS PER CUBIC FOOT PCI POUNDS PER CUBIC INCH DBA DEFORMED BAR ANCHOR PEJ PREMOUDED EXPANSION JOINT DBL DOUBLE PENN PENETRATION DEG DEGREE PERM PERMANENT DF DOUGLAS FIR PERP PERPENDICULAR DIA DIAMETER PFJ PERIMETER FELT JOINT DAG D:AGO L pip PARTIAL JOINT PENETRATION % D MENNION PL PLATE DL DEAD LOAD PLF POUNDS PER LINEAR FOOT DN DOWN PLYWD PLYWOOD DTL DETA L PNL PANEL DUP DUPLICATE pp PANEL POINT DVLP DEVELOP PREFAB PREFABRICATED DWG DRAWING PRELIM PRELIMINARY OWL DOWEL PS PRESTRESSED PSF POUNDS PER SQUARE FOOT EA EACH PSI POUNDS PER SQUARE INCH E-E END TO END PT PRESSURE TREATED EF EACH FACE PWDR POWDERROOM ELEC ELECTRICAL ELEV ELEVATION QTY QUANTITY ELVR ELEVATOR ENG ENGINEER I ENGINEERING RAD,R RADIUS EQ EQUAL RD ROOF DRAIN EQ SP EQUAL SPACE(D) RE: REFER (REFERENCE) EQUIP EQUIPMENT r REIN _ RE NFORCE (ING) Ih ES EACH SIDE REDID) REQUIRE(D) EST ESTIMATE REQMT REQUIREMENT EW EACH WAY REV REVISED/REVISION r.w EAST To WEST RF ROOF EXC EXCAVATE FIND ROUND g EX ST EXISTING RO ROUGH OPENING EXP EXPANSION RTLI ROOF TOP UNIT EXT EXTERIOR SCHED SCHEDULE FAB FABRICATE SCWD SOLID CORE WOOD PC FLOOR DRAIN SECT SECTION PON FOUNDATION SIC SQUAREFOOT FF FINISH FLOOR SHT SHEET F-F FACE TO FACE SHTG SHEATHING FIN IN F NISH Sim SIMILAR FLG FLANGE BOG SLAB ON GRADE FLR FLOOR SPEC SPECIFICATION(S) FRAMG FRAMING SPRT SUPPORT FRZR FREEZER SQ SQUARE FS FAR SIDE STD STANDARD FT FOOT STIFF STIFFENER FT2 SQUAREFOOT STIR STIRRUP FT3 CUBIC FOOT STIL STEEL FTG FOOTING STRUCT STRUCTURE/ STRUCTURAL SW SHEAR WALL G.0 ' GENERAL CONTRACTOR GA GAGE OR GAUGE T&B TOP & BOTTOM GALV GALVANIZED T&G TONGUE & GROOVE GIL GLASS T.O. TOP OF GLB GLUE LAMINATED BEAM TOW TOP OF WALL GND GROUND THD THREADITHREADED GR GRADE THK THICK/THICKNESS GINS GYPSUM WALL BOARD TL TOTALLOAD TOB TOP OF BEAM HC HOLLOW CORE TOC TOP OF CONCRETE HCA HEADED CONCRETE ANCHOR TOP TOP OF FOOTING HD HOLDOWN HEADED TOM TOP OF MASONARY HDR HEADER TOS TOP OF STEEL HGR HANGER TYP TYPICAL HM HOLLOW METAL HORIZ HORIZONTAL U.N.O. UNLESS NOTED OTHERWISE HSA HEADED STUD ANCHOR ULT ULTIMATE HSS HOLLOW STRUCTURAL STEEL HT HEIGHT VERT VERTICAL HVAC HEATING, VENTILATING & AIR COND wl WITH NSIDE DIAMETER W/o W THOUT :.8c. C INTERNATIONAL BUILDING CODE W W:DTH Icc NTERNATIONAL CODE COUNCIL WC WATER CLOSET IF :NSIDE FACE WD WOOD IN. IN". WH WATER HEATER N2 SQUAREINCHES WIC WALK IN CLOSET N3 CUBIC INCHES WP WATER PROOF INCL INCLUDE WS WATERSTOP INFO INFORMATION wr WEIGHT INT INTERIOR WWF WELDED WIRE FABRIC NTERNATIONAL RESIDENTIAL COD :RC SBU :NTERMODAL STEEL BUILDING UNIT YD YARD STATEMENT OF SPECIAL INSPECTIONS I . IN ADDITION TO STANDARD INSPECTIONS BY THE BUILDING OFFICIAL REQUIRED IN IBC SECTION 110, THE OWNER $HALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE SPECIAL INSPECTIONS AS REQUIRED IN IBC SECTION 1704. THIS SECTION REFERS TO THE SPECIAL INSPECTIONS PERTAINING TO THE STRUCTURAL SYSTEM ONLY AND DOES NO ENCOMPASS INSPECTIONS REQUIRED BY OTHER DISCIPLINES. 2. UNLESS WAIVED BY THE BUILDING OFFICIAL, THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE REQUIRED INSPECTIONS. 3. INSPECTION ON THE PROJECT, JUST THOSE DIRECTLY RELATED TO STRUCTURAL. 4. STRUCTURAL OBSERVATIONS 4.1 STRUCTURAL OBSERVATIONS MAYBE PERFORMED AS DEEMED NECESSARY BY THE STRUCTURAL ENGINEER OF RECORD. 4.2 OBSERVATION VISITS TO THE SITE BY THE ENGINEER'S FIELD REPRESENTATIVES SHALL NOT BE CONSTRUED AS AN INSPECTION OR APPROVAL OF CONSTRUCTION STRUCTURAL SPECIAL INSPECTIONS -P PERIODIC INSPECTION REQUIRED. INDICATES -C NDICATES CONTINUOUS INSPECTION REQUIRED. -R INDICATES REQUIRED FOR THIS PROJECT -NR INDICATES NOT REQUIRED FOR THIS PROJECT GENERAL INSPECTION OF FABRICATORS (1704.2.5) VERIFY THAT THE FABRICATOR MAINTAINS DETAILED FABRICATION AND QUALITY CONTROL PINR I PROCEDURES. (1704.2.5.1) SPECIAL INSPECTIONSARE NOT REQUIRED WHERE THE WORK IS DONE ON THE PREMISES OF A NR FABRICATOR REGISTERED AND APPROVED TO PERFORM SUCH WORK. (1704.2.5.1) SOILS (1706.6) NR VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN 13EARING CAPACITY. (IBC TABLE 1705.6) P NR VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. (IBC TABLE 1705.6) NR PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. (IBC TABLE 1705.6) C NR VERIFYUSEOFP PER MATERIALS, DENSITIES, AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. (IBC TABLE 1705.6) TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS P NRIPRIOR BEEN PREPARED PROPERLY (IBC TABLE 1705.6) CONCRETE CONSTRUCTION (1705.3) INSPECTION OF REINFORCING STEEL, INCLUDING PRESTRESSING TENDONS, AND PLACEMENT. (ACI 318 NR 20,25. 2,25.3,26.6.1-26.6.3) P NR - -Ch INSPECTION OF ANCHORS CAST IN CONCRETE. (ACI 318:17.8.2) NR INSPECTION OF ANCHORS POST INSTALLED IN HARDENED CONCRETE MEMBERS. (ACI 318:17.8.2.4) NR VERIFYING USE IF REQUIRED DESIGN MIX, (ACI 318: CH. 19,26A.3,26A.4) PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP C NR AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE. (ASTM C172, ASTM C31, ACI 318:26A, 26.12) FRAMEWORK FOR SHAPE, LOCATION, AND DIMENSIONS OF THE CONCRETE MEMBER BEING P NR (ACI 318:26.11.1.2(b)) WOOD CONSTRUCTION NAILING, BOLTING, ANCHORING AND OTHER FASTENING ELEMENTS OF THE LATERAL RESISTING NR SYSTEM, INCLUDING SHEAR WALLS, WOOD DIAPHRAGMS, DRAG STRUTS, BRACES & HOLDOWNS. SPECIAL INSPECTION NOT REQUIRED WHERE NAILING SPACING IS GREATER THAN IV' P VERIFY TEMPORARY INSTALLATION RESTRAINTIBRACING AND THE PERMANENT INDIVIDUAL TRU NR MEMBER RESTRAINDBRACING ARE INSTALLED PER APPROVED TRUSS PACKAGE. ONLY REQUIRED WHERE CLEAR TRUSS SPAN EXCEEDS 60 FT. STEEL CONSTRUCTION (1705.2) WELDING INSPECTION OF STRUCTURAL STEEL NR COMPLETE AND PARTIAL PENETRATION GRO_ EVVELDS.(AWSDI.1,18CI7043.1) C !! !LULTI-PAS! FILLET WELDS. (AWS D1.1, IBC 1704.3.1) NRI SNGLE_PASS FILLET WELDS � 51116" (AWS DIA, IBC 1704.3.1) NRI SINGLE -PASS FILLET WELDS - 5116"(AWS DIA, ISC 1704.3.1) P NRI FLOOR AND ROOF DECK WELDS. (AWS D1.3) SEISMIC RESISTANCE (1707.3) ICINRI INSPECTION OF FIELD GLUING OPERATIONS INSPECT ON FOR NAILING, BOLTING, ANCHORING FOR WOOD SHEAR WALLS, DIAPHRAGMS, DRAG P NR I I STRUTTHOLDOWNS SYMBOLSLEGEND FC-1D INDICATES CONTINUOUS FOOTING. SEE SCHEDULE FS-2.0 INDICATES SPOT FOOTING, F.S. SEE SCHEDULE ;S __� INDICATES FOOTING STEP ___�'INDICATES PON WALL STEP FB-1 INDICATES FLOOR BEAM. SEE BEAM SCHEDULE RB-1 INDICATES ROOF BEAM. SEE BEAM SCHEDULE 0 FRAMING MEMBER BEAM GIRDER OR DBL JOIST OVERBUILD VENEER (BRICK OR STONE)ABOVE BEARING I EXTERIORWALL SHEAR WALL ONLY NON BEARING WALL CONCRETE WALL SUPPORTING POST POST FROM ABOVE REVISION CLOUD TAG REVISION CLOUD INDICATES KEYED NOTE. SEE KEYED NOTES SPECIFIC TO EACH SHEET AWI NDICATES SHEAR WALL \f EXTENT & TYPE SEE \Z/� SHEAR WALL SCHDL I HD INDICATES HOLDDOWN X LOCATION - SEE HOLDDOWN SCHDL IST INDICATES FLOOR To FLOOR STRAP LOCATION - X SEE STRAP TIE SCHDL OF INDICATES POST LOCATION X - SEE POST SCHDL �5INDI ATES JOIST FRAMING - SECE JOIST SCHDL (#DETAIUPLAN REFERENCE 1 "-TYPICAL (TYI) OR ... SMLARSM, DETAIL SHEET REFERENCE ,-K T.O.W. INDICATES TOP OF FOUNDATIONWALL JNTO.F. INDICATES TOP OF FOOTING INDICATES FINISHED &,MAIN ._ FLOOR ELEVATION. COORDINATE W/ DESIGN PLANS GENERAL I . VISITS TO THE JOB SITE BY REPRESENTATIVES OF THE ENGINEER DO NOT CONSTITUTE APPROVAL OF THE WORK PERFORMED. 2. THE CONTRACTOR. SUBCONTRACTORS, AND OWNER AS PART OF THE PROJECT TEAM, SHALL REVIEWAND BE RESPONSIBLE FOR INFORMATION CONTAINED IN ALL PROJECT DOCUMENTS PRIOR TO INITIATION OF ANY WORK ON THE PROJECT. 3. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES, OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS BEFORE PROCEEDING WITH ANY WORK INVOLVED. IN ALL CASES, UNLESS OTHERWISE DIRECTED, THE MOST STRINGENT REQUIREMENTS SHALL GOVERN AND BE PERFORMED. DO NOT SCALE DRAWINGS. ts-CONTRAOTOR SHAkk VERW-Y Abb CONINTION&, DIMENSIONS AN9-6LffVAT40NS,-ETC., AT THE SITE AND SHALL - -- GGQFIDINATEAWRK-PERFQRM5MY-Akk -TRAOSS .......................... S. CONTRACTOR SHALL BE FULLY & SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, FOR COORDINATING ALL PORTIONS OF THE WORK, AND FOR JOB SITE SAFETY OF SUCH MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 8. CONTRACTOR S, ALL SUBS SHALL PERFORM THEIR TRADES & DUTIES IN A MANNER CONFORMING TO THE PROCEDURES & REQUIREMENTS AS STATED IN THE LATEST ACCEPTED CODE(s) ADOPTED BY THE STATE & LOCAL JURISDICTIONS. 7. CONTRACTOR IS RESPONSIBLE FOR AND SHALL BEAR THE COSTS OF CORRECTING WORK WHICH DOES NOT CONFORM TO CONSTRUCTION DOCUMENTS. THE COST OF WORK ENGINEER(S) TO APPROVE CORRECTIVE WORK SHALL BE RESPONSIBILITY OF CONTRACTOR. 8. CONTRACTOR SHALL BEAR ALL RESPONSIBILITY FOR MODIFICATIONS REQUIRED IN ARCHITECTURAL, STRUCTURAL, PLUMBING, ELECTRICAL OR MECHANICAL SYSTEMS, ECT. DUE TO SUBSTITUTION OF MA mKi-, METHODS, AND/OR EQUIPMENT. 9. THE MATERIALS AND LABOR COVERED BY THIS CONTRACT MUST CONFORM W/ THE SAFETY ORDERS OF THE LOCAL AUTHORITY HAVING JURISDICTION. STATE, OSHA AND THE DIVISION OF WORKER'S COMPENSATION. 10. ALL SUPPORT OF CONSTRUCTION LOADS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL SHORING AND BRACING REQUIRED FOR THE PROTECTION OF LIFE AND PROPERTY DURING THE CONSTRUCTION PROCESS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL PROCEDURES OF SOIL EXCAVATION, BACK FILL, AND SUPPORT OF ADJACENT PROPERTY DURING EARTHWORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 11. ALL DIMENSIONS INDICATED ON PLANS SHALL BE TO FACE OF STUDS, FACE OF CONCRETE BLOCK, FACE OF ROUGH CONCRETE, CENTERLINE OF COLUMNS, BOTTOM OF METAL DECK, AND TOP OF SLAB, UNLESS NOTED OTHERWISE. DIMENSIONS SHOWN ON STRUCTURAL DRAWINGS ARE TO BE COORDINATED WITH DIMENSIONS SHOWN ON THE ARCHITECTURAL DRAWINGS. ANY DISCREPANCY IS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO CONSTRUCTION. 12. ALTHOUGH SPECIFIC BRANDS MAY BE SPECIFIED, ALTERNATE BRANDS MAY BE USED WITH PRODUCT SPECIFICATIONS SUBMITTED TO ENGINEER FOR WRITTEN APPROVAL. EQUAL OR GREATER DESIGN VALUES MUST BE PROVIDED. 13. SHOP DRAWINGS SHALL BE PREPARED & SUBMITTED FOR REVIEW PRIOR TO FABRICATION FOR STEEL ITEMS AND FLOOR OR ROOF TRUSS SYSTEMS. ALLOW (1) WEEK FOR ENG. REVIEW. 14. MODIFICATIONS TO PLANS, FRAMING AND LOADING (DIMENSIONS, MATERIALS, DETAILS, LOCATION AND SIZE OF OPENINGS IN SHEAR OR BEARING WALLS, HOT TUBS, ETC.) FROM THAT SHOWN ON THE DESIGN PLANS CAN ALTER THE LOAD PATHS USED AND WILL VOID THE DESIGN AND PROFESSIONAL ENGINEERS STAMP (LIABILITY), WITHOUT ADDIT1014AL ENGINEERING REVIEW AND ANALYSIS INCREASING THE SIZE, NUMBER OR LOCATION OF OPENINGS IN SHEAR WALLS CAN VARY THE LOADING ON SHEAR PANELS BEYO NO THEIR LOAD CARRYING CAPACITIES. THE OWNER AND CONTRACTOR SHALL CAREFULLY REVIEW PLANS AND SPECIFICATIONS FRIO R TO INITIATION OF CONSTRUCTION. 15. BECAUSE THE RANDOM AND UNPREDICTABLE NATURE OF WIND AND EARTHQUAKE LOADING EVEN A RELATIVELY COMPLETE ANALYSIS, METHODOLOGY, AND DESIGN CANNOT ENSURE THAT THERE WILL BE NO DAMAGE TO STRUCTURES DURING SUCH EVENTS. LOCAL CODES (INTERNATIONAL BUILDING CODE (IBC)) ARE BASED ON LIFE SAFETY AND NOT "EARTHQUAKE PROOFING", ETC. OF THE STRUCTURE. IT IS EXTREMELY IMPORTANT THAT ATTENTION BE PAID TO THE PLACEMENT OF REINFORCING, HOLDOWN EMBEDS, ETC. IN THE FOUNDATIONS, NAILING OF VERTICAL AND HORIZONTAL SHEATHING (WALLS, FLOORS, AND ROOF) AND TO DETAILING SHOWN ON THE PLANS. PROPER IMPLEMENTATION IS REQUIRED TO ENSURE THE DESIRED DESIGN RESPONSE. STRUCTURAL DESIGN INFORMATION 1. GOVERNING BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE (IBC) 2. ROOF LOADING 2.1 ROOF DEAD LOAD ................................................................................... 15 PSF 2.2 ROOF LIVE LOAD .................................................................................... 20 PSF GROUND SNOW LOAD, P ....................................................................... 25 PSF FLAT ROOF $NOW LOAD, P ................................................................... 25 PSF SNOW EXID. FACTOR, C . ........................................................................ 1.0 THERMAL FACTOR, C ............................................................................. 1.0 IMPORTANCE FACTOR, I ......................................................................... 1.0 3. FLOOR LOADING 3.1 FLOOR DEAD LOAD ........................................................................... 12 PSF 3.2 FLOOR LIVE LOAD ............................................................................. 40 PSF 4. DECK LOADING 4.1 DECK DEAD LOAD ............................................................................. 10 PSF 4.2 DECK LIVE LOAD ............................................................................... 60 PSF 5. WALLWEIGHTS 5,11 TYP WALL DEAD LOAD ..................................................................... 16 PSF 6. SEISMIC PARAMETERS 6.1 SEISMIC RISK CATEGORY 6.2 SEISMIC DESIGN CATEGORY DI 6.3 IMPORTANCE FACTOR, 1 1.0 6.4 SNOW USED AS SEISMIC Wt., K 0.0 PSF 6 , 5 ANALYSIS PROCEDURE USED EQUIVALENT LATERAL FORCE 6.6 SPECTRAL RESPONSE ACCELERATIONS S....­­­ ** * * ** * * .............. ­­­­*­* ­­­ * i.29lg & .......................................................... I ......................................... 0.506g F. ............................................................................ o ........................ 1.0og F..................................................................................................... 1.5og & .................................................................................................. 0.8619 S.... ................................................................................................ 0.5069 6.7 SEISMIC FORCE RESISTING SYSTEM ............................................. LIGHT -FRAME (WOOD) R , .............. * ............ ... * .... ..... 6.5 ....... _­_'­­­ ..... .. !_2 ____ V.................................................................................................... 0.132*w 7. WIND PARAMETERS 7.1 ULTIMATE DESIGN WIND SPEED ..................................................... 1110MPH 7.2 WIND RISK CATEGORY ..................................................................... 11 7.3 WIND EXPOSURE ............................................................................... C 7A INTERNAL PRESSURE COEFFICIENT .............................................. 0.18 7.5 COMPONENTS & CLADDING PRESSURE ........................................ 16 PSF B. SOILS CRITERIA 8.1 SO:L BEARING PRESSURE ............................................................... 1,500 PSF 8 , 2 SO L SITE CLASS ............................................................................... 0 8.3 FROST DEPTH .................................................................................... 30 INCHES 8A GEOTIECH STUDY USED: .................................... ................... NO CONCRETE I . EXTERIOR FFAT WORK, CURBS, GUTTERS, ETC. fc = 3500 PSI 0 28 DAYS (MIN) k = 4000 PSI RECOMMENDED . 1.�� . . ...... ... ............................... ;'�;14ENZIZENT IN M EMENT 575 LEIS I CU YD SLABS AND WALLS 2. FOOTINGS, FOUNDATIONS, INTERIOR SLABS fo = 3000 PSI 0 28 DAYS (MIN) . .... . ...... ... ............................... MIN CEMENT 5D4 USS / CU YD 7 3. ALL CWNC RK SHALL BE PLACED, CURED, STRIPPED, & PROTECTED AS DIRECTED BY THE SPECIFICATIONS AND ACI STANDARDS & PRACTICES. DO A GOOD JOB. 4. BEFORE CONCRETE IS POURED CHECK WITH ALL TRADES TO INSURE PROPER PLACEMENT OF ALL OPENINGS, SLEEVES. CURBS, CONDUITS, BOLTS, INSERTS, ETC. S. CONTRACTOR IS RESPONSIBLE FOR DESIGN AND INSTALLATION OF ALL SHORING AND FORM WORK 6. REFER TO STRUCTURAL AND ARCHITECTURAL DRAWINGS FOR EMBEDS, MOLDS, GROOVES, ORNAMENT, CLIPS OR GROUNDS, REQUIRED TO BE ENCASED IN CONCRETE AND FLOOR LOCATION OF FLOOR FINISHES AND SLAB DEPRESSIONS. 7. IN HOT WEATHER, FOLLOW "RECOMMENDED PRACTICES FOR HOT WEATHER CONCRETING', ACI 305. IN COLD WEATHER, FOLLOW "RECOMMENDED PRACTICES FOR COLD WEATHER CONCRETING", ACI 306, CONCRETE SHALL BE PROTECTED FROM FREEZING DURING DEPOSITION AND FOR NOT LESS THAN 5 DAYS. SLAB ON GRADE NOTES 1. CONC SLAB ON GRADE SHALL BE 4" MIN THICK: NO REINFORCING REDD, U.N.O. 2. SLABS ON GRADE SHALL HAVE A VAPOR RETARDER CONSISTING OF A 6 MIL POLYETHYLENE OR APPROVED VAPOR RETARDER WITH JOINTS LAPPED NOT LESS THAN 6" PLACED BETWEEN THE CONC SLAB AND BASE COURSE. 3. SUB GRADE PREPARATION SHALL CONSIST OF 4" MIN GRAVEL OR CAPILLARY WATER BARRIER OVER COMPACTED FILL OR NATIVE SOIL. 4. FLOOR SLAB JOINTS SHALL BE COSTRUCTION OR CONTROL JOINTS PER DETAIL BELOW. S. ALL SLAB EDGES SHALL BE CHAMFERED 31*'ON EXPOSED CORNERS U.N.O. 6. REINF IS NOT REO'D IN FLOOR SLABS. W.W.F. OR # 4 BAR MAY BE USED BUT REQUIRES I-I/Z'CLR FROM TOP OF SLAB & 3" CLR FROM BOTTOM OF SLAB. CONSTRUCTION I CONTROL JOINT 1 . CONTROL JOINT SPACING RULE OF THUMB IS 24X SLA13 THICKNESS N'SLAB - V-0" MAX D.C. EACH WAY 6" SLAB - 1T-O!'MAX O.C. EACH WAY. 2. SAW CUT WITHIN 6-18 HOURS OF POURING CONC - 24 HOURS MAX CONC MUST BE HARD ENOUGH TO PREVENT RAVELING OF JOINT EDGES OR DISLODGING OF COARSE AGGREGATE. 3. ALL SLABS -ON -GRADE SHALL BE OVER 4" MIN. OF -%" FREE DRAINING GRANULAR FILL, BEARING ON UNDISTURBED NATIVE SOIL OR ENGINEERED GRANULAR FILL, HALF ROUND KEY WAY (SHOWIN) OR TAPERED CONTROL JOINT � 'T .. ...... STRIP, ZIP STRIP, AT OR SAW CUT UT T JO NT SEALER I RECOMMENDED CONST JOINT CONTROLJOINT @EXTERIOR JTS 9 TOOLED JOINT FOOTINGS AND FOUNDATIONS SOILS REPORTS I GEOTECHNICAL INVESTIGATIONS TAKE PRECEDENCE OVER THESE NOTES. I . ALL FTGS ARE BASED ON AN ALLOWABLE $OIL BEARING PRESSURE INDICATED IN DESIGN CRITERIA. ANY SOIL COND. ENCOUNTERED DURING EXCAVATION THAT IS CONTRARY TO THOSE USED FOR DESIGN OF FOOTINGS $HALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING. 2. UNLESS NOTED OTHERWISE IN DESIGN CRITERIA, A SOILS INVESTIGATION REPORT WAS NOT COMPLETED ON BEHALF OF THIS PROJECT. THE PARAMETERS REFERENCED BELOW AND THOSE USED IN DESIGN ARE BASED UPON ASSUMPTIONS. GIVEN THAT NO SOILS INVESTIGATION WAS CONDUCTED BY THE OWNER, ALL RISK AND RESPONSIBILITY REGARDING THE SOIL, DESIGN ASSUMPTIONS, AND ALL POTENTIAL RISKS (CAPACITY, SETTLEMENT, FAILURE, ETC.) REST SOLELY ON THE OWNER. IT REMAINS OUR RECOMMENDATION THAT THE OWNER ENGAGE A SOILS ENGINEER TO VERIFY SOIL PARAMETERS. 3. ALL FTGS SHALL BEAR ON UNDISTURBED NATIVE SOIL OR ENGINEERED GRANULAR FILL COMPACTED TO 95% OF MAX. DENSITY, BASED ON ASTM D1557 METHOD OF COMPACTION. FILL SHALL BE PLACED IN LAYERS NOT TO EXCEED WIN DEPTH AFTER COMPACTION AND SHALL EXTEND DOWN TO IN -SITU COHESIVE SOILS. FILL SHALL BE COMPACTED UNDER ALL CONCRETE WORK ON THE SITE. FILL BELOW FOOTINGS SHALL EXTEND BEYOND THE FOOTING EDGE AT LEAST THE DEPTH OF THE FILL. 4. NO FOOTINGS SHALL BE PLACED IN WATER OR ON FROZEN GROUND. CONTRACTOR SHALL NOTIFY ENGINEER IN CASE HIGH GROUNDWATER LEVEL ARE FOUND WITHIN FIVE FEET BELOW THE FINISHED GRADES. 5. ALL EXCAVATIONS ADJACENT TO AND BELOW FOOTING ELEVATION FOR OTHER TRADES SHALL BE ACCOMPLISHED PRIOR TO POURING ANY FOOTINGS. 6. ALL OPEN EXCAVATIONS AND TRENCHES SHALL BE SUPPORTED AND BARRICADED BY CONTRACTOR TO CONFORM WITH OSHA SAFETY STANDARDS. 7. STABILITY OF SLOPED SITES SHALL BE VERIFIED BY A SOILS ENGINEER OR OTHER QUALIFIED GEOTECHNICAL PROFESSIONAL. ON SLOPES STEEPER THAN ONE UNIT VERTICAL IN THREE UNITS HORIZONTAL, CONTRACTOR SHALL ENSURE THAT BUILDING PLACEMENT CONFORMS TO IBC SECTION 18,05.3. GEOTECHNICAL INVESTIGATION RECOMMENDED AND MAY BE REQUIRED WHERE SLOPES ARE STEEPER THAN ONE UNIT VERTICAL IN ONE UNIT HORIZONTAL. 8. ISOLATED FOOTINGS ON GRANULAR SOIL SHALL BE SO LOCATED THAT THE LINE DRAWN BETWEEN THE HORIZONTAL. 9. A GEOTECHNICAL ENGINEER EXPERIENCED IN SEISMIC ISSUES SHALL OBSERVE THE EXCAVATION PRIOR TO THE PLACEMENT OF THE FOOTING FORMS FOR ALL LOTS LOCATED WITHIN FAULT HAZARD STUDY ZONES. 10. CONTRACTOR SHALL INVESTIGATE SITE DURING CLEARING AND EARTHWORK OPERATIONS FOR FILLED EXCAVATIONS OR BURIED STRUCTURES SUCH AS CESS POOLS, CISTERNS, FOUNDATIONS. ETC. IF ANY SUCH STRUCTURES ARE FOUND THE ENGINEER SHALL BE NOTIFIED. 11. CONCRETE FOOTINGS ARE PERMITTED TO BE CAST AGAINST EARTH WHERE SOIL CONDITIONS DO NOT REQUIRE FORMING. 12, THE TOP SURFACE OF FTGS SHALL BE LEVEL. THE BOTTOM SURFACE OF FOOTINGS IS PERMITTED TO HAVE A SLOPE NOT EXCEEDING 1:10. FOUNDATION BACK FILL I . USE ONLY LIGHT MANUALLY PROPELLED COMPACTORS WITHIN 5'OF FOUNDATION. 2. INSTALL DAMP PROOFING (MIN 6 MIL POLYETHYLENE W/ W MIN JOINT LAPS) BETWEEN SLA13-ON-GRADE. & BASE COURSE. 3. TO USE UTAH AMEND MIN FDN REINF, BACK FILL SHALL BE SOIL CLASSIFICATION TYPES GW, GP, SIN OR SP, CLEAN GRAVEL / SAND I GRAVEL�STAND MIXES, WELL GRADED OR POORLY GRADED. YOU CANNOT BACK FILL Wt CLAY OR CLAY MIXES. 4, BACK FILL SHALL NOT BE FROZEN. SUBMERGED OR SATURATED;N GROUND WATER. 5. NOTIFY ENGINEER IF EXPANSIVE OR COLLAPSING SENSITIVE SOILS ARE FOUND. FIN PRIOR TO PLACING BACKFILL PROVIDE LATERAL SUPPORT AT T.O. PON (FLOOR FRAMING) AND AT B.O. PON (SLAB -ON -GRADE) OR INSTALL SHORING (DESIGN BY CONTRACTOR). ENSURE FDN CONC HAS REACHED AT LEAST 75% OF DESIGN STRENGTH (2000 PSI MIN- VERIFY NO. OF DAYS REQD Wt CONC SUPPLIER) SEAL ALL FORM TIE HOLES AND RECESSES THEN APPLY DAMP PROOFING MATERIALS, T.O. FTG TO GRADE, REINF @ JTS -WATERPROOFING REDO W/ HIGH WATER TABLE COMPACT BACK FILL TO 85% MIN - 90% MAX SEE NOTES NO FTG OR SLAB SHALL BE PLACED IN WATER OR ON FROZEN GROUND DEDICATED FDN DRAIN REQD PER CODE (IBC 1807) UNLESS -SITE IS WELL- DRAINED GRAVEL OR SAND/GRAVEL MIXTURE SOIL (CLASS 1). REOD IF CALLED FOR ON PLANS. FOUNDATION AND SILL PLATE NOTES 1. ALL SILL PLATES RESTING ON EXT FOUNDATION WALLS LESS THAN 8 INCHES FROM EXPOSED EARTH AND ON CONCRETE OR MASONRY SLA13S IN DIRECT CONTACT WITH EARTH SHALL BE OF NATURALLY DURABLE OR PRESERVATIVE -TREATED WOOD. 2. FOUNDATION PLATES OR SILLS SHALL BE BOLTED OR ANCHORED TO THE FOUNDATION WITH NOT LESS THAN W INCH -DIAMETER STEEL BOLTS (ASTM A307) OR APPROVED ANCHORS. BOLTS SHALL BE EMBEDDED AT LEAST 7 INCHES INTO CONCRETE OR MASONRY, ANCHOR BOLTS SHALL BE INSTALLED IN THE CENTER THIRD OF THE WIDTH OF THE PLATE. SEE STUDISILL PLATE CUTTING & NOTCHING DETAIL. 3. ANCHOR BOLT SIZE AND SPACING ARE DETERMINED FROM LATERAL LOADING (WIND & SEISMIC) ON THE STRUCTURE. SEE PLAN AND SHEAR WALL SCHEDULE FOR SIZE AND SPACING. A PROPERLY SIZED NUT AND WASHER SHALL BE TIGHTENED ON EACH BOLT TO THE PLATE. ANCHOR BOLTS FOR STRUCTURES LOCATED IN SEISMIC DESIGN CATEGORY D, E OR F SHALL INCLUDE 0,229 INCH BY 3 INCH BY 3 INCH PLATE WASHERS. S. METAL PRODUCTS (FASTENERS AND CONNECTION HARDWARE) IN CONTACT WITH PRESSURE -PRESERVATIVE AND FIRE -RETARDANT -TREATED WOOD MUST BE CORROSION RESISTANT. FASTENERS SHALL BE OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. DO NOT USE STANDARD CARBON -STEEL OR ALUMINUM PRODUCTS. EXCEPTIONS: 1. ONE-HALF INCH DIAMETER OR GREATER STEEL BOLTS. FASTENERS AND CONNECTORS COATED WITH PROPRIETARY ANTI -CORROSION TECHNOLOGIES MAY BE USED. CONSULT INDIVIDUAL HARDWARE MANUFACTURERS FOR SPECIFICS REGARDING THE PERFORMANCE OF THEIR PRODUCT. 6. ANCHOR BOLTS SHALL 13E INSTALLED WITHIN MIDDLE THIRD OF THE SILL PLATE. SILL PLATE CUTTING/NOTCHING ADD ANCHOR BOLTS WHEN DRILLED OR NOTCHED � 1/3 WIDTH OF SILL PLATE 31KN�K11,V'SQUARE WASHERS REQUIRED FOR SEISMIC DESIGN CATEGORY D,E, OR F. MIN (2) A.B. PER RE MAY BUILDING CITYOI SECTION -SEEPLAN & SHEAR WALL SCHEDULE tJT.2x CONT PRESSURE EQ EQ TREATED SILL WHEN SILL PL OVERHANG PLATE - SEE FDN & EXCEEDS 1/2" FOR 2x4 OR SILL PL BILL PL NOTES. 1.1a'FOR 2x6 INSTALL T TIGHT FITTING 2x CON OVERf­ MIN ED I. M PRESSURE TREAT _ D HANG EIRG SUPPORTLEDGER . ................ D.C. UN;i�;;i��ANW'­­­­­ WALL SECTION SILL PLATE PLAN VIEW SILL PLATE ANCHOR BOLT DIA END DISTANCE'd' 1/2" 1 5/8.1 12" 4-3/8" 3/4" 12" 5-1/4" z 0 �6T hdium AE STRUCTURAL ENGINEERING 635 WEST 5300 SOUTH, SUITE 203, SALT LAKE CITY, UT 84M PHONE: (8011974-5101 PAX: (SDI) 974-ST02 1.,ECl POPE REMODEL 18209 76TH AVE IN EDMONDS WY TIEK DESIGN GROUP .EETME: COVER SHEET DESIGN TEAM LEAD: GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS D, wzz A7110 61' �TC u WITIUCTURAL ONIY _CT Eip� t,jW-,AU_.11,llT,l,REE"' Cv) '­ ARK, BEIJ 1*� CHECKED GEJ, ALG c� W-E, NOV 5, 2018 Nov 05, 2018 3:54pm s" - 0 01 0 PERMIT SET CONCRETE REINFORCING 1. ALL REINFORCEMENT SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH ACI DETAILING MANUAL AND ACI STANDARD. 2. ALL REINF AND EMBEDS SHALL BE SECURELY TIED IN PLACE PRIOR TO POURING CONCRETE. 3. ALL METAL REINFORCEMENT SHALL BE DEFORMED TYPE BARS (EXCEPT #2 BARS) AND SHALL CONFORM TO THE REQUIREMENTS OF THE'STANDARD SPECIFICATIONS A.S.T.M. A61 5 GRADE 60. 4. REINFORCEMENT SHALL BE FREE FROM MUD, OIL, OR OTHER NONMETALLIC COATINGS THAT ADVERSELY AFFECT BONDING CAPACITY. 5. MAINTAIN MINIMUM CONC. COVER FOR REINF AS FOLLOWS: UNFORMED CONIC AGAINST & PERM. EXPOSED TO EARTH ........................ ; .................................... 3- FORMED CONIC EXPOSED TO EARTH OR WEATHER (#6 THRU #18 BARS) ..................................... 2" FORMED CONIC EXPOSED TO EARTH OR WEATHER (#5 & SMALLER BARS) .................................. . . . SLABS & WALLS NOT EXPOSED TO WEATHER (#I I & SMALLER BARS) .......................................... 3/4' BEAMS, COLUMNS USED FOR PRIMARY REINF & TIES ...................................................................... I'liz, 6. SEE BAR DEVELOPMENT & LAP SPLICE TABLE FOR REINFORCING DEVELOPMENT & LAP SPLICE - I SET REINF G BAR LAP F FDN ­tT �IRE.TION �4: A REINF R _a EIIIN ER BARS WAII TlICINES1 B Fall I jt�j 11 ORNER 'N.RSECTION CLR FDN CORNERS A -A TYP FDN SECTION BAR LAP mP ir HO KH`RIZREINF FM Fm__ DRUSECORNER R INTERSEDT" ,ORNER FTG CORNERS B-B SIISDIAG 18-INFM ,V Fr�'MFI -.�RS.CNIXENDE TA LER STEPS )SPTH ALLOWEDONBEDROCK STEP IN FTG / FDN C-C BAR DEVELOPMENT AND LAP SPLICE 1. DEFINITIONS: Ld: ....................................... TENSION DEVELOPMENT FOR REINGORCEMENT SATISFYING THE FOLLOWING CONDITIONS: SLA13S & WALLS: .............. CLEAR SPACING � 2db AND CONCRETE CLEAR COVER > db. BEAMS & COLUMNS: CLEAR COVER SPACING > db AND CONCRETE CLEAR COVER > db. U: ....................................... DEVELOPMENT LENGTH FOR TOP BARS IN TENSION. , Lab: .................................... TENS:ON LAP SPL:CE LENGTH FOR OTHER THAN TOP BARS (CLASS B). Lsbt: ................................... TENS ON LAP SPL CE LENGTH OF TOP BARS. db: ...................................... NOMINAL BAR DIAMETER (INCHES). TOP BARS: ........................ HORIZONTAL REINFORCEMENT WITH MORE THAN 12 INCHES OF FRESCH CONCRETE CAST BELOW. 2. MULTIPLY VALUES IN SCHEDULE BY 1.5 IF CLEAR SPACING OR CONCRETE COVER DO NOT MEET REQUIREMENTS FOR Ld IN NOTE 1. 3. MULTIPLY VALUES IN SCHEDULE BY 1.3 FOR USE IN LIGHTWEIGHT AGGREGATE CONCRETE. 4. FOR EPDXY COATED BAR: MULTIPLY VALUES IN SCHEDULE BY 1.5 FOR BARS WITH CLEAR COVER � 3db OR CLEAR SPACING . Sdb, OTHERWISE MULTIPLY VALUES BY 1.2. S. a* FOR BUNDLED BARS OF THREE OR LESS MULTIPLY LENGTH BY 1.2. b FOR BUNDLED BARS OF FOUR OR MORE MULTIPLY LENGTHS BY 1.33. C. INDIVIDUAL BAR SPLICES WITHIN A BUNDLE SHALL NOT OVERLAP. ENTIRE BUNDLES SHALL NOT BE LAP SPLICED. 6. SCHEDULE LENGTHS ARE FOR fy=60ks! REINFORCING. BAR DEVELOPMENT & LAP SPLICE LENGTH SCHEDULE B R SIZE fe = 3000 PSI Ld I Lt I L.b Labt I L.b E t #3 17" 22. 22" 28" 151, 1 191, 1191, 25" #4 Z, 29'. ".. 19;; 26' 25" 33" #5 8., 36. _77 41" #6 33" 43" 567- - 2". 37.: 49" #7 48" 63. _Ff� 42.' 1 '. 71" #8 55" 72. 58" 1 62" 1 62" 111. REINF STANDARD HOOKS REBAR DATA SCHEDULE BAR NO. db (IN.) ---&(IN.) 6' db FINISHED HOOK IDTH #3 O�375 odil 2.26 4 3" W #4 00500 0.20 3.00 4 4" 1. 11, #5 OmS25 0.31 3.75 4 6' 3-314" 10" #6 0.750 0444 4.50 4 6" 4-1/2" 2" #7 0.875 0.60 5.26 5.25 7" 5-1/4" 14' #8 7000 0.79 6.00 6.00 8., 6" 16" DEFINITIONS: #9 1.128 1.00 9.02 6.77 11-3/4" 191, db: ACTUAL DIAMETER OF BAR (IN.) 10" 1.270 .27 10.16 7fl2 lq-lldll 2 'd FO #3BARTO$8BAR __T_ MIS b R .410 1 .56 11.28 BAB 14-3/W' S*db FOR #9 TO #11 BAR 1INIS­ e Zf- -,, f D --TIES& STIRRUPS LUMBER I . MEMBER GRADES SHALL BE AS FOLLOWS; GLU-LAM BEAMS; GUS (Simpla Span) ......................................................................... 24F.V4 DFjDF (Cantilevered) .......................................................................... 24F.V8 DFJDF JOISTS & HEADERS ..................................................................................................... DOUG FIR #2 STIR POST...................................................................................................................... DOUG FIR 01 BTR STUDS NON-BRG WALLS ..................................................................... ..... ................ D.F. STUD GRADE BTR STUDS BEARING WALLS .............................................................................................. DOUG FIR #2 BTR Lvus................................................................................................................................ i.9E DF LVL Fb = 2,800 PSI SILL PLS IN CONTACT WICONC ................................................................................... DOUG FIR #2 STIR (PRES:URE TREATED FOR MOISTURE PROTECTION 2. ALL MULTIPLE PLATES AND LEDGERS SHALL BE NAILED TOGETHER WITH 16d NAILS AT 8 IN. ON CENTER. STAGGERED SIDE TO SIDE 3. STUD WALLS SHALL RUN CONTINUOUS BETWEEN POINTS OF HORIZONTAL SUPPORT. PROVIDE BRACING WHERE OTHERWISE. 4. SOLID 2 IN. NOMINAL BLOCKING SHALL BE PROVIDED AT ENDS OR POINTS OF SUPPORT OF ALL WOOD JOISTS AND TRUSSES. CROSS BRIDGING OF NOT LESS THAN I IN. X 3 IN. MATERIAL SHALL BE PLACED IN ROWS BETWEEN SUPPORT POINTS. NOT TO EXCEED 8 FT APART, FOR SPANS OF 14 FT AND GREATER. INSTALL CROSS BRIDGING FOR WOOD4 JOISTS AS PER MFGR. S. MIN NAILING SHALL BE AS PER INTERNATIONAL BUILDING CODE. 6. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED LUMBER OR FOUNDATION REDWOOD. ALL WOOD SUPPORT MEMBERS EXPOSED TO WEATHER SHALL BE TREATED OR PROTECTED TO PREVENT MOISTURE OR WATER ACCUMULATION ON THE SURFACE. ENDS OF UNTREATED WOODSEAMS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS SHALL HAVE A CLEARANCE OF NOT LESS THAN 0.5 INCH ON TOP, SIDES AND ENDS. 7. FASTENERS SUCH AS STAPLES, CAN ONLY BE SUBSTITUTED FOR NAILS AT A RATE EQUAL TO LOAD VALUES PROVIDED BY I.C.B.O. APPROVAL. S. BOLT HOLES SHALL BE 1116"MAX LARGER THAN THE BOLT SIZE. RETIGHTEN ALL NUTS PRIOR TO CLOSING IN. MULTI -MEMBER BEAMS M_-NA,_1 W' ly6' 12" O.0 EACH SIDE. _ZN4#g ......... .. L @� �H I ER STAGGERED T&B D.C. - STAGGERED DEL 2x OR TRIPLE 2x OR LVL QUAD 2x OR LVIL STUD CU INGINOTCHING NOTE: IF ERG STUDS ARE DOUBLED -THEY T C,)H U-P, MAY BE 13ORED W1 2" HOLE IN 2X4 & 3-1/4!'HOLE IN 2X6 @ NO MORE THAN TWO SUCCESSIVE UN M STUDS . ADD SIMPSON "STUD SHOE' TO EDGE WHERE LIMITS OF TABLE ARE EXCEEDED. STUD ELEV STUD NOTCHING I BORI G STUD USE OTCH HOLE BEARING ZX4 7/8" 1-31811 2X6 1-11" 2-116' NOW BEARING 2X4 1-318" 2" 2X6 �1/8-' 3-11W I -JOIST ALLOWABLE HOLES i. i-1/2!'HOLE MAY BE CUT ANYWHERE IN WEB OUTSIDE OF SHADED ZONE. PROVIDE AT LEAST 3" OF CLEARANCE FROM OTHER HOLES. 2. Do NOT CUT HOLES LARGER THAN I-10ROUND IN CANTILEVERS. 3. DO NOT CUT OR NOTCH FLANGES. FOR MINIMUM DISTANCE FROM SUPPORTS, SEE MANUFACTURER'S SPECIFICATIONS HOLES ALL-ED PER THIS DETAIL DO IN OVER -RIDE MFR REQUIREMENTS. IF MFR REQUIREMENTS ARE MORE STRICT, THEY SHOULD BE FOLLOWED. CLOSELY GROUPED ROUND HOLES ARE PERMITTED IF GROUP PERIMETER MEETS REQUIREMENTS FOR ROUND OR SQUARE HOLES. MIN. SP ENSION 'r- 6" F, 7r OF LARGEST HOLE BRGf _8RG/ SUPPORT SUPPORT LVL ALLOWABLE HOLES 1 . MAX HOLE DIAMETER OF T'. 2. NO HOLES IN CANTILEVERS. 3. ROUND HOLES ONLY. 4. NO MORE THAN 3 HOLES PER SPAN 5. DETAIL VALID FOR UNIFORMLY LOADED BM ONLY. ADDITIONAL ANALYSIS REDID FOR POINT LOADED BEAM. 6. HOLES ALLOWED PER THIS DETAIL DO NO OVER -RIDE MFR REQUIREMENTS. IF MFR REQUIREMENTS ARE MORE STRICT, THEY SHOULD BE FOLLOWED. HOLES ALLOWED IN SHADED AREA ONLY LVL BEAM PER PLAN SPAN _' t �_ I SPAN BRGI SPAN SUPPORT BRG/SUPPORT SHEAR WALL NOTES I . ALL EXTERIOR WALLS, INTERIOR WALLS INDICATED ON THE PLANS, AND VERTICAL SUR ACES AT STEPS IN ROOF SHALL BE SHEATHED WITH APA RATED 24/0 (OR BTR) COX PANEL SIDING OR OTHER GRADES COVERED IN UBC STANDARD NO. 2". TYPICAL NAILING SHALL BE AS INDICATED IN SHEAR WALL SCHEDULE. NAIL ALL PANELS WITH INDICATED NAIL SIZE AT 12 IN. O.C. ALONG INTERMEDIATE SUPPORTS. 2. BLOCK ALL HORIZONTAL PANEL EDGES WITH 2 IN. NOMINAL OR WIDER FRAMING. FRAMING AT ADJOINING PANEL EDGES SHALL BE 3-INCH NOMINAL OR WIDER AND NAILS SHALL BE STAGGERED WHERE NAILS ARE SPACED 3 INCHES OR LESS ON CENTER. 3. ALL SHEATHING SHALL EXTEND CONTINUOUS FROM SILL PLATE TO ROOF OR FLOOR SHEATHING. SEE NOTE 2 ABOVE. 4. SHEATHING SHALL EXTEND CONTINUOUS FROM FLOOR FRAMING TO H IGH ROOF FRAM ING ON UPPER LEVEL EXTERIOR WALLS ABOVE A LOW ROOF. 5. NAILS SHALL BE SPACED NOT LESS THAN 3/8 IN. FROM EDGES AND ENDS OF SHEATHING AND SHALL BE DRIVEN FLUSH BUT SHALL NOT FRACTURE THE SURFACE OF THE SHEATHING. GAP ALL SHEATHING 11WAT PANEL EDGES. 6. ANCHOR BOLTS FOR ALL SHEAR WALLS SHALL BE SIZED AND SPACED AS INDICATED IN SCHEDULE ABOVE NTH 7 IN. MIN EMBED. PLATE WASHERS A MINIMUM OF 3 INCHES BY 3 INCHES BY 1/4 INCH THICK SHALL BE USED ON EACH BOLT. 7. STAPLES SHALL BE 16 GA (MIN) X 11/2" MIN LENGTH Wl 7/16'MIN CROWN. SHEAR WALL NAILING 1. SHTG MAY BE INSTALLED IN VERT OR HORIZ ORIENTATION. 118" GAP AT END JOINTS & 1/16-- GAP a SIDE JOINTS. 2. ALL EXTERIOR WALLS & INTERIOR WALLS INDICATED ON PLANS SHALL BE SHEATHED & NAILED AS SW-1 MIN. 3. SHEATHING E.N. REQD @ ALL HOUDOWN POSTS. 4. INTERMEDIATE SHEAR PANELS ARE WALL SECTIONS VW HEIGHT/WIDTH RATIOS TOO HIGH ("NARROW) TO MEET CODE LIMITS. SHEATH & NAILS SW-1 OVERDIUVEN FASTENER NOTES: THE CODE REQUIRES THAT SHEAR WALL SHTG NAILS BE DRIVEN FLUSH BUT SHALL NOT FRACTURE THE SURFACE OF THE SHTG. I . NO REDUCTION IN SHEAR OR ADDITIONAL FASTENERS REDO IF: a. FASTENERS UNIFORMLY OVERDRIVEN BY LESS THAN Ye' b. FASTEN IRS RECESSED DUE TO SWELLING FROM MOISTURE. c. WHERE ! 20-A OF FASTENERS ARE OVERDRIVEN BY WMAX. 2. WHERE 40% OF FASTENERS ARE OVERDRIVEN, INSTALL ONE ADDITIONAL FASTENER FOR EVERY Two. 16 GAGE X I V'STAPLES W1 MIN 7/,," CROWN WIDTH MAY BE USED IF ADDITIONAL NAILS ARE SPACED <Z'. FOR S.W. TYPES HIGHER > THAN SW-2, LOCATE 3x OR (2) 2X STUDS @ ADJOINING PANEL JOINTS, BOTH HORIZ &VERT WAN SHEAR PANELS. (2) 2X STUDS To BEFACE NAILED Wl 10d EACH FACE STAGGERED . MATCH S.W. PANEL NAIL SPACING. LOCATE PANEL EDGES @ > PLATES. BLKG, SOLID RIM JST OR OTHER SOLID FRMG MEMBERS, E.N. PERIMETER (EDGE) NAILING WALL ELEVATION "STRAP OPENINGS' INDICATES SHEAR PANELS THAT ARE FULLY NAILED INCLUDING ABOVE & BELOW OPENINGS AS INDICATED BY SHEAR WALL SCHEDULE. ENINGS SHALL HAVE CS16 x 2-V' MIN STRAP TIE FULLY NAILED EACH IDE&T&BOF OPENINGS. INSTALL SOLID HORIZ BLOCKING BEHIND STRAPS. BUILDING ISOMETRIC VIEW NOTCH PLATE & SHTG AS MIN ANGLE HOLDOWN LOCATIONS 1" MAX. (SEE PLANS) OFFSET . .... ......... ONE#4X HOLDOWN TOLERANCE CONT REBAR (FDN BAR) IN SHEA CONE ROOF TRUSS NOTES 1. TRUSSES SHALL BE DESIGNED FOR THE FOLLOWING MINIMUM UNIFORM LOADS. TOP CHORD DEAD LOAD & LIVE LOAD ........... SEE DESIGN CRITERIA BOTTOM CHORD DEAD LOAD ............................ 5 PSF (MIN) THE DESIGN ENGINEER SHALL BE NOTIFIED IF HEAVY ROOFING MATERIAL SUCH AS CLAY TILE, ETC. IS USED. 2. EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE FOLLOWING INFORMATION LOCATED WITHIN 2 FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD: A. IDENTITY OF THE TRUSS MFG. B , THE DESIGN LOADS C. THE SPACING OF THE TRUSSES 3. TRUSSES AND GIRDERS SHALL BE DESIGNED FOR ALL TRIBUTARY LOADING, UNBALANCED SNOW LOADS, EAVE LOADS, DRIFT, AND SLIDING LOADS AS PER LATEST ADOPTED CODES. PROVIDE CALCULATIONS TO EOR FOR RECORDS. 4. TRUSSES AND GIRDER LOADS SHALL BE DESIGNED TO SUPPORT ALL MECHANICAL LOADS FROM APPLICABLE HVAC EQUIPMENT. S. GABLE END TRUSSES SHALL BE DESIGNED TO CARRY SUPPORTED LOADS OVER GABLE END WINDOWS AND BAYS. 6. DESIGN TRUSSES & GIRDERS TO LIMIT DEFLECTION TO THE SPAN (INCHES) DIVIDED BY 360 (U360) OR I INCH MAX, WHICHEVER IS SMALLER. 7. CHECK DIMENSIONS WITH ARCHITECTURAL DRAWINGS AND FIELD VERIFY WITH CONTRACTOR. TRUSS MANUFACTURER IS RESPONSIBLE TO PROVIDE WEB AND CHORD MEMBERS TO SATISFY LOADING AND CONNECTION REQUIREMENTS. 8. CONTRACTOR / TRUSS SUPPLIER SHALL SUBMIT SHOP DRAWINGS AND ERECTION DRAWINGS FOR REVIEW BY THE DESIGN ENGINEER PRIOR TO FABRICATION OR ERECTION. SHOP DRAWINGS SHALL BE REVIEWED AND STAMPED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE STRUCTURE RESIDES. 9. TRUSS PACKAGE SHALL BE SUBMITTED TO THE AUTHORITY HAVING JURISDICTION AS DEFERRED SUBMITTAL AFTER REVIEW BY DESIGN ENGINEER. 10. ALTHOUGH, SUGGESTED CONNECTION HANGER SIZES MAY BE INDICATED ON THE PLANS, ALL TRUSS HANGER CONNECTIONS (I.E. TRUSS TO BEAM, TRUSS TO GIRDER TRUSS, AND GIRDER TRUSS TO GIRDER TRUSS) SHALL BE DESIGNED BY THE TRUSS SUPPLIER/ MANUFACTURER. CONNECTION HANGER SIZE AND ENGINEERING SHALL BE INCLUDED WITH THE SHOP DRAWINGS. 11. TRUSS PRE-ENGINEERED JOINT CONNECTORS SHALL HAVE I.C.C. CERTIFICATION. 12. ANY CHANGES TO THE TRUSS CONFIGURATION SHOWN ON PLANS SHALL BE APPROVED IN WRITING BY THE DESIGN ENGINEER PRIOR TO CONSTRUCTION 13. TRUSS LAYOUT SHALL PROVIDE REQUIRED OPENINGS FOR ACCESS PANELS, DOORS, SKYLIGHTS, ETC. 14. MFR TO CHECK FOR PRE-FAB TRUSS BLOCKING ON ANY TRUSS WITH HEEL �12". ROOF SHEATHING NOTES: 1. ALL SHTG: APA RATED EXP 1 2. % APA RATED SHTG MIN RECOMMENDED UNLESS STRONGER PANEL REQD FOR SNOW LOAD (USE MAX SNOW LOAD, F,). WITH DRIFTING, ETC. COORDINATE Wl ROOF TRUSS SUPPLIER. 3. NAIL W18d COMMON NAILS (.131" DIA, 2Yj'LENGTH) 4. TIGHTER NAILING PATTERN AND /OR 10d COMMON NAILS (.14V'DIA, 3" LENGTH) MAYBE REDD FOR HIGH LATERAL LOADS. SEE PLANS. WOOD STRUCT PANEL 8HTG CONT OVER (2) OR MORE SPAN- W/ ENGTH AXIS IERP TO SUPPORTS n �A UA EDGE NAILING @ DIAPHRAGM PERIM, ALL EXT WALLS& INTERIOR SHEAR WALLS JOISTS OR TRUSSES SEE FRMG PLAN& BLOCK SOLID 0 ERG PTS STAGGER END JOINTS - LAYOUT PANELS TO ELIMINATE ANY WIDTH LESS THAN V-9' LAYOUT PLAN 1 $51 8 F V/00//F �?'Vffi EMMME 0, ng , ------ ----- ROOF PANEL SHTG SCHEDULE 0 0 SPAN .a " INS EM41 , IS 1. , , IS 12111 fPANEL EDGE NAILING Y." GAP END JOINTS )',."GAP SIDE JOINTS FASTENER TO V PANEL EDGE JST OR TRUSS SECTION ROOF PANEL SHEATHING NAILING SCHEDULE WIND PANEL ROO I ST NINGZONE SPEED LOCATION 140 MPH EDGES 4 FIrLD OL ,�� .:: EoiL C� FlEt D IrOC. 6"OC, 6"0.0 STRUCTURALSTEEL 1. ALL STRUCTURAL STEEL SHALL BE ASTM A-992 (EXCEPT FOR TUBE COLUMNS WHICH SHALL BE ASTM A-500-13, Fy = 46 KSI) AND SHALL COMPLY WITH THE "STANDARD SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS" OF THE A.I.S.C. AND WITH THE A.I.S.C. CODE OF STANDARD PRACTICE. 2. ALL BOLTS FOR STEEL TO STEEL, SHALL BE A325, TIGHTEN TO SPECIFIED TORQUE AS PER AISC REQUIREMENTS, BOLTS FOR CONCRETE AND STEEL TO WOOD, SHALL BE ASTM A307, U.N.O. 3. WELDED REBAR OR BOLTS WILL NOT BE ACCEPTED IN LIEU OF WELDED STUD ANCHORS AND DEFORMED BARS. WELDED STUD ANCHORS AND DEFORMED BARS SHALL BE APPLIED USING MANUFACTURER APPROVED WELDING PROCEDURES. 4. ALL WELDING SHALL CONFORM TO MOST CURRENT ADOPTED ANS DIA REQUIREMENTS AND SHALL BE MADE WITH E70XX ELECTRODES BY WELDERS CERTIFIED FOR THE WELD TO BE DONE. CERTIFICATION SHALL BE CURRENT WITHIN THE PAST TWELVE MONTHS. 5. ALL BEARING PLATES FOR EMS AND COLUMNS RE"NG ON MASONRY OR CONC SHALL BE UNDERLAIN FULLY WITH A HIGH COMPRESSION, NON -SHRINK GROUT. 8. PRIOR TO FABRICATION AND ERECTION, SHOP DRAWINGS FOR ALL STIL ITEMS SHALL BE REVIEWED BY THE DESIGN ENGINEER. ALL STL SHALL BE PRIMED I PAINTED IN THE SHOP. ALL STIL THAT MAY BE EXPOSED TO EXT. SHALL BE SHOP PAINTED TO INHIBIT RUST. WELD AREAS SHALL BE TOUCHED UP IN THE FIELD. 9. SPECIAL INSPECT ONS AND TESTING OF WELDS AS REQUIRED BY THE LATEST ADOPTED BViLUINlj Uvwt:(ts) lop SHALL BE PROVIDED BY THE OWNER. COPIES OF ALL INSPECTION REPORTS SHALL BE FORWARDED TO THE DESIGN ENGINEER. 10. U.N.O. ON SPEC. DTLS HIGH -STRENGTH BOLTS ARE REDD TO BE TIGHTENED ONLY TO THE SNUG -TIGHT CONDITION, THE SPECIAL INSPECTOR NEED ONLY VERIFY THAT THE CONNECTED MATERIALS HAVE BEEN DRAWN TOGETHER AND PROPERLY SNUGGED. RESUB MAY 16 N'll BulgiNg'- "E'T < Hill 11 z 182 4 Iridium AE STRUCTURAL ENGINEERING 635 WEST 5300 SOUTH, SUITE 203, SALT LAKE CITY, UT 84123 PHONE: (801) 974-5101 FAX: (801) 974-5TO2 .OiSm. POPE REMODEL 18209 76TH AVE W EDMONDSWY ­E- TIEK DESIGN GROUP SN__- COVER SHEET DESIGN TEAM GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS Ella w9ml ZLI T. STRUCTURAL ONLY 00PYRIGHT-A IGHTS RESERVED I­COPYRIGHTA_�L�R SE_R REIR.­ N BY PRIOR ­TTEN _ISSIONONlY Cq ARK, BBJ GEJ, ALG EFS-U­TE: NOV 5, 2018 Go NOV 05, 2018 3:54pm S-001- .TAM$ PERMIT SET 22'.31/2. f - "AY EXISTING FOOTING L - - - - - - - - - - - - - - - - - - - LZ�C 1 7 77f/ -bi LI LF i 1 1 1 F- - - - - - - - - - - - I F - - - - - - - - - - - - z p J 0 01 CRAWL SPACE 0 U. - - - - - - r2 Z z EXISTING FOOTING rF-- . . . . .. . - - - - -- - - - - - - - - - - - - - - - - - - - 5 F S-500 21 1 1 HD /AXISTING FOOTING 0 81 1� I *> F 0 z . . . . . . EXISTING FOO'MO CUD" L, U'4 z FS-2.5 0 iD F 1 z < EXISTING FOOTING �� �I�NG L -\ EXISTING FOOTING nHID EX STING FOOTING :4. F�C-1.7 1w. T-94 - 16-5yi' iz-1iyy 114, FOOTING & FOUNDATION PLAN 1-1 4- 8. 1 16- 0. 10. IKEYED NOTES 1. RECESS T.O. FDN FOR SLAB 2. INSTALL 2OFT #4 REBAR OR #4 BARE COPPER WIRE @ B.O. FTG & EXTEND 4FT MIN FROM T.O. FDN FOR UFFER GROUND. COORDINATE W/ ELECTRICIAN. 3. INSTALL (4) #4xlV-0-- DIAG BARS AT TOP OF SLAB TO PREVENT A. THIS IS ONE PAGE OF A SET OF PROJECT DOCUMENTS, AND MAY NOT BE USED ALONE. THE CONTRACTOR, SUBCONTRACTORS AND OWNER, AS PART OF THE PROJECT TEAM, SHALL REVIEW AND BE RESPONSIBLE FOR INFORMATION CONTAINED IN ALL PROJECT DOCUMENTS PRIOR TO INITIATION OF ANY WORK ON THE PROJECT. B. DETAILS ARE NOTED ON THE PLANS IN TYPICAL LOCATIONS AND SHALL BE REPEATED WHERE SIMILAR CONDITIONS EXIST. SEE TYPICAL DETAILS AND GENERAL NOTES. C. SEE STRUCTURAL DETAIL SHEETS (" XX) FOR STRUCTURAL NOTES & DETAILS D. SEE PLANS, SHEAR WALL NOTESAND SCHEDULE FOR WALL SHEATI` IN AND ANCH�BOLTS- U.N.O. MINIMUM ANCHOR EMBED INSTALLED AT 32 INCHES MAX ON CENTER. PLATE WASHERS A MINIMUM OF 3 INCHES BY 3 INCHES BY 114 INCH THICK SHALL BE USED ON EACH BOLT. E. FOUNDATION WALLS SHALL BE LATERALLYSUPPORTED UNTIL SUPPORT MEMBERS (FLOOR FRAMING AND SLABS) HAVE BEEN INSTALLED. F. BASEMENT WINDOWS SHALL BE INSTALLED TO MEET EGRESS, LIGHT AND VENTILATION REQUIREMENTS PER IBC. WINDOWS, FRAMES AND AREA WELLS ARE FURNISHED AND LOCATED ON SITE BY CONTRACTOR. G. DIMENSIONS SHOWN SHALL BE COORDINATED Wl DESIGN DRAWINGS. FOUNDATION SCHEDULE FOUNDATION WALL REINF STEEL MAX HEIGHT THICK VERT I NORM — NOTOPEDGE S"MIN �w 5UPPORT SEE RETAINING WALL DTLS V, #4 @ IV'"@ 1 a. #4 @ 12" #4 @ 12�� IV 0 � .0 1001 #4 @ 10" 117— �o 10" AM @ 10" 4 @ IV' —12'-- #5 @ 10" # �u NOTES: REINF FREE STANDING FDN (NO BACKFILL EITHER SIDE a. FDN EQUALLY BACKFILLED EA SIDE) SAME AS VFDN SEE FOUNDATION REINFORCEMENT DETAIL FOR GRAPHICAL REPRESENTATION OF FOUNDATION REINF. FOR WALLS TALLER THAN 12'4', SEE DETAILS FOOTING SCHEDULE MARK WIDTH LENGTH THICK CROSSWISE REINFORCING LENGTHWISE REINFORCING �O. SIZE LENGTH NO. I SIZE LENGTH FC-1.5 1141 CONT 10" 2 #4 CONT FC-1.7 I,-&, CONIT 1&, 2 #4 CONT FC-2 0 Z-01 CONIT 10" 2 06 CONT FS-2.6 Z-V T-s" 12* 4 #4 Z-O" 4 #4 2-0" FS-3.0 T-0 Y-O. Izl 4 #4 2L6" 4 #4 Z-r NOTE& - SPACE REINF. EVENLY THROUGH FOOTING W/ 3"CUEARANCE AT OUTSIDE EDGE. z 0 IJ, Iridium AE STRUCTURAL ENGINEERING 635 WEST 5300 SOUTH, SUITE 203, SALT LAKE CITY, LIT 84123 PHONE: ISDI) 974-5101 FAX: (801) 974-5102 POPE REMODEL 18209 76TH AVE W EDMONDS WA MEW'. TIEK DESIGN GROUP FOOTING & FOUNDATION PLAN DESIGN TEAM GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS J.-TA 1�"%.— R Spj a L ONLY MAy 16 2M �qqm�o ul-.Omm slo— DI 1: ARK, BBJ t- '"EIIEDI: GEJ, ALGi ,�j NOV 5,2018 Co 6 PLOT— Nw 05, 2018 3:54pm S-100 VA.. PERMIT SET EXISTING FOOTING — --- — — — — — — — — — — FF - - - - - -- F- - - - - - - - - - - - z 0 F-, V- APPROVZO JN JOB Sw i FS-2.5� T b 9 N R EMSED PLAN APPROVED cl , "OFEDMONDSBUI INGDIVISION PLANS EXAMTNE DATE FOOTING & FOUNDATION PLAN 1/4"=11-0" 77�� 1 8. 1 ol 1 1 w 10, IKEYED NOT 1. RECESS T.O. FDN FOR SLAB 2. INSTALL 20FT #4 REBAR OR #4 BARE COPPER WIRE @ B.C. FTG & EXTEND 4FT MIN FROM T.O. FON FOR UFFER GROUND. COORDINATE W/ ELECTRICIAN. 3. INSTALL (4) #4x4'-O" DiAG BARS AT TOP OF SLAB TO PREVENT CRACKING. 4. INSTALL HD-3 To REPLACE THE STHD CUT IN FOOTING AND FOUNDATION PLAN NOTES I A. THIS IS ONE PAGE OF A SET OF PROJECT DOCUMENTS, AND MAY NOT BE USED ALONE. THE CONTRACTOR, SUBCONTRACTORS AND OWNER, AS PART OF THE PROJECT TEAM. SHALL REVIEW AND BE RESPONSIBLE FOR INFORMATION CONTAINED IN ALL PROJECT DOCUMENTS PRIOR TO INITIATION OF ANY WORK ON THE PROJECT. B. DETAILS ARE NOTED ON THE PLANS IN TYPICAL LOCATIONS AND SHALL BE REPEATED WHERE SIMILAR CONDITIONS EXIST. SEE TYPICAL DETAILS AND GENERAL NOTES . C. SEE STRUCTURAL DETAIL SHEETS (S-5XX) FOR STRUCTURAL NOTES & DETAILS D. SEE PLANS, SHEAR WALL NOTES, AND SCHEDULE FOR WALL SHEATHING AND ANCHOR BOLTS, U.N * 0. MINIMUM ANCHOR BOLTS SHALL BE 51&'0 WITH 7 INCHES MIN EMBED INSTALLED AT 32 INCHES MAX ON CENTER. PLATE WASHERS A MINIMUM OF 3 INCHES BY 3 INCHES BY 1/4 INCH THICK SHALL 13E USED ON EACH BOLT. E. FOUNDATION WALLS SHALL BE LATERALLYSUPPORTED UNTIL SUPPORT MEMBERS (FLOOR FRAMING AND SLABS) HAVE BEEN INSTALLED. F. BASEMENT WINDOWS SHALL BE INSTALLED TO MEET EGRESS, LIGHT AND VENTILATION REQUIREMENTS PER IBC. WINDOWS, FRAMES AND AREA WELLS ARE FURNISHED AND LOCATED ON SITE BY CONTRACTOR. G. DIMENSIONS SHOWN SHALL BE COORDINATED W/ DESIGN DRAWINGS. FOUNDATIONWALL REINF STE L MAX HEIGHT THICK VERT I HORIZ :W NOTOPEDGE IrMIN #4@16"1#4@IZ' -w SUPPORTISMEERETAINING WALL DTLS Ir @ 12, TYR 10, 07—#4 10"#4@10" --107.—#4 IV'#4@IW' 0 10' #6@19'#4@IW' NOTES: REINF FREE STANDING FDN (NO BACKFILL EITHER SIDE & FDN EQUALLY BACKFILLED EA SIDE) SAME AS V FDN SEE FOUNDATION REINFORCEMENT DETAIL FOR GRAPHICAL REPRESENTATION OF FOUNDATION REINF. FOR WALLS TALLER THAN IZ-(r. SEE DETAILS FOOTING SCHEDULE MARK WIDTH LENGTH — THICK — CR SWtSE REINFORCING LENGTHWISE REINFORCING NO. SIZE LENGTH_ NO. SIZE LENGTH FC-1.5 V-el CONT 10" 94 CONT FC-1.7 l'-w CONT la" 2 #4 CONT HT FC-2.0 Z-0" CONT 10" 2 #5 CONT Iffi-4 FS-2.5 Z-W Z-W 12' 4 ffi4 4 Z-01' FS-3.0 Y-0 v-0" 12" 4 #4 4 94 Z-61' NOTES: - SPACE REINF. EVENLY THROUGH FOOTING W1 WCUEARANCE AT OUTSIDE EDGE. :71 4ARK r MC)DEL# HD-2 HDU4-SDS2.5 3" (10) SDS 114-X2.lrr I Sir 1 12- 1 4565 STHD14(RJ) 3' (2,4)16dSINKERS 1 1 �E-- D�5 HDUS-SDS2.5 3- (14) SDS 1114"X2-10 I 5V 12" SE45 HD-6 HDU8-SDS2.6 a, SDS IWX2-112 71W IT 6765 5_lr HD-7 HDUll-SDS2.5 (30) SDS l/#X2-1)2 1 16' 9335 IOTES. ALL HOLDOWNS ARE SIMPSON BRAND. EQUIVALENT STRENGTH HD MAY BE USED. STRONGER HOLDOWN MAY BE USED; HD-2 MAY BE USED IN LIEU OF HD -I MULTIPLE OPTIONS FOR HD-X ARE SHOWN TO ALLOW CAST IN PLACE OR POST INSTALLED HOL OWN (RJ) INDICATES USE OF STRAPS AT RIM JOIST APPLICATION. NOT REQ-0 FOR ALL APPLICATIONSR le VALUES SHOWN FOR TENSION ARE FOR WMIN FDN WALL THICKNESS. l6dium AE STRUCTURAL ENGINEERING 05 WEST 5300 SOUTH, SUITE 203, SALT LAKE CITY, UT 84123 PHONE: (801) 974-5101 PAX: (801) 974-6102 PROJMT� POPE REMODEL 18209 76,TH AVE W EDMONDS WA TIEK DESIGN GROUP 11 1-11 1 1 FOOTING & FOUNDATION PLAN DESIGN TEAM GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS goes 'GIST .R ISTIRMETO ARCHI CT M C IV C. ANGUM W SMEOF ASHINGTO a 'o' , , STRUCTU91AL ONLY COPYRIGHT- ALL RIGHTS RESERVED —OPYR— USE—REP—MON W-0—EN PEWISSION ONLY ARK, BBJ C4 GEJ, ALG OCT 15,2019 06 v- OC 115. 2019 3;2SpM SHEETNO, S-1 00 PERMIT SET 8Q)XIq-OD78� MAIN FLOOR FRAMING PLAN 1/4"=11-0" NIM11MMIM I 87" 1 16 0, 1- 4' V lo �i � DESCRIPTION GRADE/ NOTES DF-2 (2) STUDS/TRIMMERS DF#2 DF-3 (3) STUDSrrRIMMERS DF#2 DF-4 (4) STUDSITRIMMERS DF#2 DF-4A 4 x 4 POST DF#1 or BTR �W_4_6 I x OiST *1 T DF- PC T D2.1 2.�, MTR TS-4.4 JHSS 4 x 4 x 114" A500-GR.B-46 NOTES: POST SIZE IS MINIMUM REaD. SIZE & GRADE MAY BE INCREASED FOR ARCHITECTURAL DETAILING OR CONTRACTOR PREFERENCE. ADDITIONAL STUDS TO BE USED UNDER WIDE BMS TO PROVIDE FULL SM REARING ALL BUILT UP POSTS SHALL BE BUILT FROM STUDS TO MATCH WALL THICKNESS. FLOOR BEAM SCHEDULE SEE DESIGN CRTIERIA FOR LOADING MARK SIZE FOOTNOTEII FEI -1 FEI -2 L2) 1-3/4' X 9-1/2" ��S) FS-3 21 (3) 1-VlV'XlS-LVL(S) FS 4 ORIAMOX26 -113 (3) 1-WXlW_L_V_L(S) FS -5 ORAMOM !3 OR KEY. 1. HEADER 2. FLUSH IN FLOOR 3. DROPPED 4. CANTILEVER END OF BEAM 5. ALIGN WITH WALLIPOST ABOVE 6. T ' 0. BM T.O. JOISTS 7. T. . SM 1-1W BELOWT.O. JOISTS NOTES: -DEEPER AND/OR WIDER MEMBERS MAY BE SUBST U SU IT TEDOFSAMEGRADE. OTHER BET TUITIONS SHALL NOT BE MADE W/O PRIOR WRITTEN APPROVAL FROM ENGINEER. -ALL EXT. SMS (DECKS, ETC.) SHALL BE EXT. GRADE & SHALL 13E CLEARLY MARKED. - SEE S-001 FOR REQUIRED BEAM GRADE. IFLOOR FRAMING PLAN NOT A. DETAILS ARE NOTED ON THE PLANS IN TYPICAL LOCATIONS AND SHALL BE REPEATED WHERE SIMILAR CONDITIONS EXIST. SEE TYPICAL DETAILS AND GENERAL NOTES' B. SEE STRUCTURAL DETAIL SHEETS (S.6XX) FOR STRUCTURAL NOTES & DETAILS. C. PLACE 2 STUDS MINIMUM AT ALL BEAMS, HEADERS AND GIRDER TRUSS BEARING POINTS WITH SPANS GREATER THAN SIX FEET, UNLESS NOTED OTHERWISE. MULTIPLE STUDS AND COLUMNS SHALL EXTEND CONTINUOUS TO FOUNDATION OR SUPPORTING BEAM BELOW. USE MULTIPLE SOLID BLOCKING AT FLOORS. D. SEE FLOOR SHEATHING NOTES FOR FLOOR SHEATHING SIZE & NAILING. E. AT FLUSH BEAMS USE SIMPSON LBV SERIES (WEB JOISTS) OR JS SERIES (WOOD JOISTS) TOP FLANGE JOIST HANGERS EACHJOIST U.N.O. F. ARRANGE JOIST LOCATIONS AT BATHROOM AND KITCHEN AREAS TO AVOID CONFLICT WITH PLUMBING. G. FLOOR JOISTS UNDER FIREPLACE HEARTHS MAY NEED SPACING REDUCED AND/OR SUBSTITUTED W/ LVUs TO SUPPORTTHE ADDED LOADING. VERIFY W/ ENGINEER. H. HOT TUBS OR OTHER OWNER INSTALLED ITEMS THAT IMPOSE HEAVY LOADS ON STRUCTURAL MEMBERS WILL REQUIRE ADDITIONAL ENGINEERING IF NOT SHOWN ON ORIGINAL PLANS USED FOR DESIGN. STRUCTURAL MEMBERS MAY NEED TO BE INCREASED FOR THE ADDITIONAL IMPOSED LOADING . 1. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED LUMBER OR FOUNDATION REDWOOD. ALL WOOD SUPPORT MEMBERS EXPOSED TO WEATHER SHALL BE TREATED OR PROTECTED TO PREVENT MOISTURE OR WATER ACCUMULATION ON THE SURFACE. I I FLOOR SHEATHING I I A. TYPICAL FLOOR SHEATHING SHALL BE 314 IN., T&G APA RATED 48/24 EXPOSURE I SHEATHING "LED WITH 8d RING SHANK NAILS AT 6 IN. D.C. AT ALL PANEL ENDS, SUPPORTED EDGES, TOP OF SHEAR WALLS (ALL EXTERIOR WALLS ARE SHEAR WALLS) AND ALL BLOCKING; Bd AT 12 IN. O.C. ALONG INTERMEDIATE FRAMING MEMBERS. NAILING SHALL BE SPACED AT 3/8 IN. MIN FROM EDGE OF PANEL. B. LAY SHEATHING WITH FACE GRAIN AT RIGHT ANGLES TO FRMG W1 END JOINTS STAGGERED (SEE TYP DETAILS). C. BLOCK JOISTS SOLID AT ALL BEARING z 0 Iridium AE STRUCTURAL ENGINEERING 635 WEST 5300 SOUTH, SUITE 203, SALT LAKE CITY, UT 84123 PHONE 18011974-5101 PAX:1801)974-SIO2 POPE REMODEL 18209 76TH AVE W EDMONDS WA ­E- TIEK DESIGN GROUP SHEET—E MAIN FLOOR FRAMING PLAN DESIGN TEAM GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS jy 16 2019 ���IGWS R E —.0— ..R Sy Al .�'? 0RmI­,ENPEF.1 .N CV) ARK, BBJ GEJ, ALG ISSUE— NOV5,2018 co P�­ Nov 05, 2018 3:54pm SH—M.. S-i 01 UAMI PERMIT SET P, m. � AM v 0, , o 10-3 h? , _116 lZc., llli8aVxl*9Aq n AppRoUku MW OF 0831T FI-- P-x . -p"s&ONA,, -rp_� "­ _7 REVISED PLAN APPROVED CITYOFEDMONDSBU INGDPWAISIO PLANS EXAMINER DATE I& 4_1 -MAIN: FLOOR FRAMING PLAN 1/4"=l �_Ul I - - 'Ll -11, � ol 11 4' 10, 1 11-7/8" FLOOR JOIST SCHDL 140 PSF LIVE LOAD AND 12 PSF DEAD LOAD SERIES MAX $PAN SPACING FLANG WIDTH Til 110 18`5" 16' 1,V4" FJ-1 LPI 18 IV-111 _16" 2­11T BCI 5000 - 1.7 16- Z. _k TJI 210 _!� 19'-3" 1&, 2-111W FJ-2 LPI 20, 1W-Wl 16" 2-10 BC1 6000 - 1.8 19141 1&, 2-5116" TJI 230 j!wjW 16`- 2,611W FJ-3 UPI 32+ 2(Y-T lir 2-10 rs—ci —6soo- 1.8 Zow- ir 2.wifr TI 360 2V-11" IV' Z-5116" FJ-4 UPI 36 121'-0- !::: r2l:F I = TjI 560 3' - 1&- 3-10 FJ-5 UPI 56 3-112" SCI 90 - 2.0 IS- 3-10 NOTES: SPAN IS CLR DIST. BETWEEN SUPPORTS SHTG SHALL BE GLUED, NAILED FOR SPANS. rDF') POST SCHEDULE MARK DESCRIPTION GRADEI NOTES DF-2 (2) sTuDsrrRimmERs DF412 DF-3 (3) STUDSITRIMMERS DF#2 DF4 (4) STUDSITRIMMERS DF#2 DF-4.4 4x4POST DF#1 or BTR DF4.6 4x6POST __�&F#1 Or STIR _*W,"TX6POST ��Flfl TS-4.4 jHSS4x4xI/4" A500­GR.B-46 NOTES: POST SIZE IS MINIMUM REaD. SIZE & GRADE MAY BE INCREASED *OR ARCHITECTURAL r DETAILING OR CONTRACTOR PREFERENCE. ADDITIONAL STUDS TO BE USED UNDER WIDE BMS TO PROVIDE FULL BM BEARING ALL BUILT UP POSTS SHALL BE BUILT FROM STUDS TO MATCH WALL THICKNESS. 1. INSTALL SW 0 x 10" TITEN BOLTS IN PLACE OF J-BOLTS FOR SILL PLATES AT EXIST, WALL. SEE SHEAR WALL SCHDL FOR SPACING. FLOOR BEAM SCHEDULE SEE DESIGN CRITERA FORLOADING MARK SIZE FOOTNOTES FS -1 (2) - 2 X 8 (S) 1 FB-2 L2) 1-3/4'X9-i/Z-LVL(S) 1 FB 4 (2) 1-W4�'Xll-7/frLVL(S) 2,5 _ (2) 1-NN' X 9-10 LVUS) WITH (2) FB4 Z'FUTCH PLATES 3 (3) I-W4'Xl&'LVL(S) FB -5 ORWIOX28 30R4,6 FB-6 — 6 X 12 TIMBER 6 �� I �X 11 IER F. � 1 .4, X 9-112. LVL(S) KEY' 1. HEADER 2. FLUSH IN FLOOR 3. T.O. BEAM T.O. JOISTS 4. T.O. BEAM 1-112" BELOW TO. JOISTS 6. ALIGN NTH WALUPOST ABOVE S. DROPPED NOTES: -DEEPER ANDIOR WIDER MEMBERS MAYBE SUBSTITUTED OF SAME GRADE. OTHER r 'USSTITUT DNS SHALL NOT BE MADE W/O PRIOR I( WRITTEN APPROVAL FROM ENGINEER. ALL EXT. EMS (DECKS, ETC.) SHALL BE EXT, GRADE & SHALL BE CLEARLY MARKED. SEE S_001 FOR REQUIRED BEAM GRADE. I I FLOOR FRAMING PLAN NOTES I I A. DETAILS ARE NOTED ON THE PLANS IN TYPICAL LOCATIONS AND SHALL BE REPEATED WHERE SIMILAR CONDITIONS EXIST. SEE TYPICAL DETAILS AND GENERAL NOTES. B. SEE STRUCTURAL DETAIL SHEETS (S-5XX) FOR STRUCTURAL NOTES & DETAILS. C. PLACE 2 STUDS MINIMUM AT ALL BEAMS. HEADERS AND GIRDER TRUSS BEARING POINTS WITH SPANS GREATER THAN SIX FEET, UNLESS NOTED OTHERWISE. MULTIPLE STUDS AND COLUMNS SHALL EXTEND CONTINUOUSTO FOUNDATIONOR SUPPORTING BEAM BELOW. USE MULTIPLE SOLID BLOCKING AT FLOORS. D. SEE FLOOR SHEATHING NOTES FOR FLOOR SHEATHING SIZE & NAILING. E. AT FLUSH BEAMS USE SIMPSON LBV SERIES (WES JOISTS) OR JB SERIES (WOOD JOISTS) TOP FLANGE JOIST HANGERS EACHJ0IST U.N.O. F. ARRANGE JOIST LOCATIONS AT BATHROOM AND KITCHEN AREAS TO AVOID CONFLICT WITH PLUMBING. G. FLOOR JOISTS UNDER FIREPLACE HEARTHS MAY NEED SPACING REDUCED AND/OR SUBSTITUTED W/LVI2.TO SUPPORTTHE ADDED LOADING. VERIFY W/ ENGINEER. H. HOT TUBS OR OTHER OWNER INSTALLED ITEMS THAT MPOSE HEAVY LOADS ON if ME STRUCTURAL =MSERSWILL REQUIRE ADDITIONAL ENGINEERING IF NOT SHOWN ON ORIGINAL PLANS USED FOR DESIGN. UCTURALMEMBERS MAYNEEDTOBE INCREASED FOR THE ADDITIONAL IMPOSED LOADING. 1. ALL LUM13ER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED LUMBER OR FOUNDATION REDWOOD. ALL WOOD SUPPORT MEMBERS EXPOSED TO WEATHER SHALL BE TREATED OR PROTECTED TO PREVENT MOISTURE OR WATER ACCUMULATION ON THE SURFACE. FLOOR SHEATHING A. TYPICAL FLOOR SHEATHING SHALL BE 3/4 IN., T&G APA RATED 48124 EXPOSURE I SHEATHING NAILED WITH 8d RING SHANK NA LS AT 6 IN. D.C. AT ALL PANEL ENDS, SU PORTED EDGES, TOP OF SHEAR WALLS (ALL EXTERIOR WALLS ARE SHEAR WALLS) AND ALL BLOCKING; Od AT 12 IN. D.C. ALONG INTERMEDIATE FRAMING MEMBERS. NAILING SHALL BE SPACED AT 3/8 IN. MIN FROM EDGE OF PANEL. B. LAY SHEATHING WITH FACE GRAIN AT RIG ANGLES TO FRMG W/ END 'DINTS STAGGERED (SEE TYP DETAIL.'. C. BLOCK JOISTS SOLID AT ALL BEARING n Iddium AE STRUCTURAL ENGINEEMNG 635 WEST 5300 SOUTH, SUITE 203, SALT LAKE CITY, UT 84123 PHONE: ($Dlj 774�5101 FAX: (801) 974-5102 POPE REMODEL 18209 76TH AVE W EDMONDS WA CLIENT'. TIEK DESIGN GROUP MAIN FLOOR FRAMING PLAN DESIGN TEAM GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS W 9 a "a ` G T � ljRCETD IR 1,R ]ED EST ARRHI ML, . A.0'M MLY C ANOUM 9 a 'o, i""'To TE Of WiAINGTO STPIUCTMAL ONLY ,COPYRIGHT ALL RIGHTS RESERVED MOOPYR­ USEW—ROOVOTON WPRO­ENPERNlSSlONO­ cv) ARK, BBJ t*- C4 GEJ, ALG I `­—OCT 15, 2019 P"T mn. Oct 15,2019 3:28pm jj lei SHEET NO. of IS-101— PERMIT SET SECOND FLOOR FRAMING PLAN 1/4"=11-0.. � j 11 1 1 1 1 1 8 1 16' 0 10, IROOF BEAM SCHEDULE 9 E '�2'1'- FOOTNI 1 2 (S) I I RB -3 10 1-&#' X 9-1 /Z' EXTERIOR WALL FRMG SCEHDULE] WALL STUD LUMBER PERP. PARA. TYPE— 3 GRADE FRMG FRMG 2x4 1&' DOUG FIR V-W' 91-W. 2x4 12" DOUG FIR W-V iop-w 2X6 16' DOUG FIR 14�4" 14%6" 2x6 12" DOUG FIR I&-0" 1&-(r 1-Y4"x 6­112" 'B" 1.55 E LSL 15'-0' LSL STUDS 15- 1-31N, x 5-Ir-I LSLSTUDS 'r 1.55 E LSL 1V-W 16'-S" DBL2xS is" DUG FtIR1'84.." 8'-6" DBL LSL 1-61 L.L �SS E 'B'__ LSL 7-1/4" W, E L.L 2.' NOTES: TABLE DESIGNED FOR 115 MPH EXPOSURE'C'50 PSF FLAT ROOF SNOW LOAD FRAMING PERP. To WALL ISHALL NOT EXCEED 45'-V'SPAN. CONTACT ENGINEER FOR MAX HT OF STUDS SUPPORTING LONGER SPANS THAN 45'-D MAX HT. REFERS To UN -BRACED WALL HEIGHTS. FULL HEIGHT STUD WALLS WHICH ARE BRACEDLATERALLY (TRUSSES OR RAFTERS) WAU HEIGHTS MAY BE REDUCED TO THE POINTAT WHICH THE FIRST LATERAL BRACE OCCURS. SPECIAL STUD SPACING CONDITIONS TO BE NOTED ON FRAMING PLANS. lj5�� I KEYED NOTES 1. =REMOVED ASSUMED TO BE,NON-BRG. BEAR NC LT EOR IF WALLS ARE- rDF') POST SCHEDULE Q� �x I I MARK I DESCRIPTION GRADEINOTES DF-2 (2) STUD&TRIMMERS DF-3 (3) STUDSITRIMMERS DFA ) STUDSTRIMMERS DF#2 DF-4A 4x4POST DF#1 or STIR DF-4A 4.6POST DF#1 or STIR DF-6.6 6xSPOST DF#l.rBTR A500-GR.B-46 TS-4.4 SS4x4xlW NOTES: POST SIZE IS MINIMUM RE9D. SIZE & G E 'TUFr MAY BE INCREASED FOR ARCHITEC L DETAILING OR CONTRACTOR PREFERENCE. ADDITIONAL STUDS TO BE USED UNDER WIDE SMS TO PROVIDE FULL BM BEARING ALL BUILT UP POSTS SHALL BE BUILT FROM STUDS TO MATCH WALL THICKNESS. KEY'. 1. HEADER 2. FLUSH IN ROOF 3 SLOPED WITH ROOF 4 CANTILEVER END OF BEAM 5. T. 0. BEAM = B.C. TRUSSES/JOISTS NOTES, - DEEPER ANDIOR WIDER MEMBERS MAY BE SUBSTITUTED OF SAME GRADE. OTHER SUBSTITUT DNS SHALL NOT BE MAD. I( WRITTEN APPROVAL FROM ENGINEER. ALL EXT. EMS (DECKS, ETC.) SHALL BE EXT. GRADE & SHALL BE CLEARLY MARKED. HEADERS 17'-V'WIDE @ GABLE END WALLS ARE NOT REQUIRED WHEN STRUCTURAL GABLE TRUSSES ARE USED. SEE S-001 FOR REQUIRED BEAM GRADE. FLOOR BEAM SCHEDULE I SEr DESIGN CRITERIA FOR WADING MARK SIZE OTI'IOTE FS -1 FB -2 1��. LVL(Sl FB -3 (2) !-W# X 11-70LVLS) FB4 (3) IZ X 18. 1 in (8) OR'AMGK26 .R rel -5 (3) 1-3hV'Xlff'LVL(S) O__ OR " S KEY'. 1. HEADER 2. FLUSH IN FLOOR 3. DROPPED 4. CANTILEVER END OF BEAM S. ALIGN WITH WALUPOST ABOVE 6. T.O. BM T.O. JOISTS 7. T.O. SIM 1-11T BELOW T.O. JOISTS -DEEPER ANDIOR VODER MEMBERS MAY BE r 'U S �TU ED OF AME GRADE. OTHER U:�T T S IS T TONS SHALL NOTSEMADEW/O PRIOR I( WRITTEN APPROVAL FROM ENGINEER. ALL EXT. BMS (DECKS, ETC.) SHALL BE EXT. GRADE & SHALL BE CLEARLY MARKED. SEE S-001 FOR REQUIRED BEAM GRADE. I I FLOOR FRAMING PLAN NOTES I A. DETAILS ARE NOTED ON THE PLANS IN TYPICAL LOCATIONS AND SHALL BE REPEATED WHERE SIMILAR CONDITIONS EXIST. SEE TYPICAL DETAILS AND GENERAL NOTES. B. SEE STRUCTURAL DETAIL SHEETS (S.5XX) ,OR STRUCTURAL NOTES & DETAILS. C. PLACE 2 STUDS MINIMUM AT ALL BEAMS, HEADERS AND GIRDER TRUSS BEARING POINTS WITH SPANS GREATER THAN SIX FEET, UNLESS NOTED OTHERWISE. MULTIPLE STUDS AND COLUMNS SHALL EXTEND CONTINUOUS TO FOUNDATION OR SUPPORTING BEAM BELOW. USE MULTIPLE SOLID BLOCKING AT FLOORS. D. SEE FLOOR SHEATHING NOTES FOR FLOOR SHEATHING SIZE & NAILING. E. AT FLUSH BEAMS USE SIMPSON LEV SERIES (WEB JOISTS) OR JB SERIES (WOOD JOISTS) TOP FLANGE JOIST HANGERS EACHJOIST U.N .0. F. ARRANGE JOIST LOCATIONS AT BATHROOM AND KITCHEN AREAS TO AVOID CONFLICT WITH PLUMBING. G. FLOOR JOISTS UNDER FIREPLACE HEARTHS MAY NEED SPACING REDUCED AND/OR SUBSTITUTED W1 LVL2s TO SUPPORTTHE ADDED LOADING, VERIFY W/ ENGINEER. H. HOT TUBS OR OTHER OWNER INSTALLED ITEMS THAT IMPOSE HEAVY LOADS ON STRUCTURAL MEMBERS WILL REQUIRE ADDITIONAL ENGINEERING IF NOT SHOWN ON ORIGINAL PLANS USED FOR DESIGN. STRUCTURAL MEMBERS MAY NEED TO BE INCREASED FOR THE ADDITIONAL IMPOSED LOADING. 1. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED LUMBER OR FOUNDATION REDWOOD. ALL WOOD SUPPORT MEMBERS EXPOSED TO WEATHER SHALL BE TREATED OR PROTECTED TO PREVENT MOISTURE OR WATER ACCUMULATION ON THE SURFACE. I I FLOOR SHEATHING 2�i A. TYPICAL FLOOR SHEATHING SHALL BE 3/4 IN., T&G APA RATED 4at24 EXPOSURE I SHEATHING NAILED WITH 8d RING SHANK NAILS AT 6 IN. D.C. AT ALL PANEL ENDS, SUPPORTED EDGES, TOP OF SHEAR WALLS (ALL EXTERIOR WALLS ARE SHEAR WALLS) AND ALL BLOCKING: 8d AT 12 IN. D.C. ALONG INTERMEDIATE FRAMING MEMBERS. NAILING SHALL BE SPACED AT 318 IN. MIN FROM EDGE OF PANEL. B. LAY SHEATHING WITH FACE GRAIN AT RIGHT ANGLES TO FRMG Wl END JOINTS STAGGERED (SEE TYP DETAILS). C. BLOCK JOISTS SOLID AT ALL BEARING Iridium AE STRUCTURAL ENGINEERING 635 WEST 5300 SOUTH, SUITE 2D3, SALT LAKE CITY, LIT 84123 PHONE: (801) 974-5101 FA)C (8011974-5102 POPE REMODEL 18209 76TH AVE W EDMONDS WA TIEK DESIGN GROUP SECOND FLOOR FRAMING PLAN DESIGN TEAM GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS, IRED 1.11 T. 'A"I"no: ESURCTURALONLY Y 16 2019 ��ENT G.P.YR......T-_AU_ RIGHTS RESERVED VPRIOR Ml ARK, BBJ GEJ, ALG cm 4111—NOV5,20`18 I Go V_ PL­ NOV 05,2018 3:54p. S-1 02 13 -PERMIT SET lin Fm"Loi" goinkg An PLANS DOE am 40 Of,) WE (2) 2" x 9-1/Z' STEEL PLATES _,. T.R._ S LTC 12 T ... RED T.B ( ),.".'.S.,."LVLS 2T .ITCH PLATES _iii�71SED PLAN APPROVED CITYOFEDMONDS NG DIVISION r '.7 PLAN DATE SECOND FLOOR FRAMING PLAN 1/4'1=11-011 I- I---- I - __ - L 1'6' 01 1 4' 8 111 EXTERIOR WALL FRMG SCEHDULE WALL STUD LUMBER PERP. PARA. TYPE SPAC,G GRADE FRMIG FRNIG 2X4 16" DOUG FIR Ir-O" 91-01, 2.4 IZ' DOUG FIR 9'-0" 101-VI 2X6 16" DOUG FIR 1,f-g' 1*6' z(6 17 DOUG FIR 16'-U' 16-W 1_31w, x 5-112" 6" 1.56 E LSL 16-9' 1 V-U' LSL STUDS I-Wx5- LSLSTUDS 12' 1 .55 E LSL 16'-6" iv-91 DBL2x6 16' DOUG FIR 18!-&' 8`6" DEL LSL V. 1_SS USL �55 EE Z LSL 7-1/4- 6" 1 LSL 2&4r 21�O�P NOTES: TABLE DESIGNED FOR 115 MPH EXPOSURE'C' 50 PSF FLAT ROOF SNOW LOAD FRAMING PERP. To WALL SHALL NOT EXCEED 46-0" SPAN. CONTACT ENGINEER FOR MAX HT OF STUDS SUPPORTING LONGER SPANS THAN 45'-0 MAX HT. REFERS TO UN -BRACED WALL HEIGHTS. FULL HEIGHT STUD WALLS WHICH ARE BRACEDLATERALLY (TRUSSES OR RAFTERS) WAU HEIGHTS MAY BE REDUCED TO THE POINT AT WHICH THE FIRST LATERAL BRACE OCCURS. SPECIAL STU DITiONS TO BE CON ON F=ING NOTED PLANS. KEYED NOTES 1. WALLS REMOVED ASSUMED TO BE NON-BRG' CONSULT EOR IF WALLS ARE BEARING 2. SEE FLITCH PLATE DETAIL ON THIS SHEET FOR CONNECTION REQUIREMENTS. 3. INSTALL (2) LS9(, CLIPS TO CONNECT EXIST. EMS. 4. FRAME NEW 2X4 WALL INSIDE EXIST. GARAGE WALL FOR SUPPORT OF WALL ABOVE. CO ECT SILL PLATE TO EXIST FDN W/ SWO X,.�N I TITEN.D@3Z'O.C. OF POST SCHEDULE MARK i DESCRIPTION GRADEINOTES DF-2 (2) STUDSrrRIMMERS OF#2 DF.3 (3) STUDSfTRIMMERS DF#2 DF-4 (4) STUDSrrRIMMERS DP#2 DF-4A 4 x 4 POST DPNI or STIR DF-4.6 4.6POST DP#I or BTR DF-6.6 6 x 6 POST DP#1 or BTR TS-4A HSS4x4xllV' AS00-GFLB4S NOTES: POST SIZE IS MINIMUM REOD. SIZE & GRADE MAY BE INCREASED FOR ARCHITECTURAL DETAILING OR CONTRACTOR PREFERENCE. ADDITIONAL STUDS TO BE USED UNDER WIDE EMS TO PROVIDE FULL SM BEARING ALL BUILT UP POSTS SHALL BE BUILT FROM STUDS TO MATCH WALL THICKNESS. ROOF BEAM SCHEDULE I L 001NOTE9 (q2g) 2 X 8 (S) R -21(2) X 11-71&'LVI48) RBP -3 (2) 1-&4'X 9-IrZ LVIJS) 1 2 Ft �-� -1 1. HEADER 2. T.O. BEAM = B.O. TRUSSESIJOISTS NOTES: -DEEPER AND/OR WIDER MEMBERS MAY BE SUBSTITUTED OF SAME GRADE. OTHER SU13STITUTIONS SHALL NOT BE MADE WIO PRIOR WRITTEN APPROVAL FROM ENGINEER. -ALL EXT. EMS (DECKS, ETC.) SHALL BE EXT. GRADE & SHALL BE CLEARLY MARKED. HEADERS -71-VI WIDE @ GABLE END WALLS ARE NOT REQUIRED WHEN STRUCTURAL GABLE TRUSSES ARE USED. SEE S-001 FOR REQUIRED BEAM GRADE. FLOOR BEAM SCHEDULE SEE DESIGN CRYTERIA FOR LOAD MARK SIZE :OOTNOTE, FB .1 (21-2XB(S) 1 M -2 (Q l-wg-X9-l/z.LVvS) I 121 I-VVXll.71&'LVLIS) 2,5 (2) 1-W4'X 9-10 LVL[S) WITH (2) FB 4 T FUTCH PLATES 3 (3) 1-W4!'Xlg'LVL(S) FS -5 ORWIOX26 3 OR 4. 5 FS -6 6 X 12 TIMBER 6 FEI� RX fM)!NTl4VX_I1_11Z'LV"S) 2- KEY: 1. HEADER 2 FLUSH IN FLOOR 3 T.O. BEAM T.O. JOISTS 4. T.O. 13EAM 1-10BELOWT.O. JOISTS 5. ALIGN WITH WALLIPOSTABOVE 6. DROPPED NOTES: - DEEPER ANDIOR WIDER MEMBERS MAY BE BLEST TUTED OF SAME GRADE. OTHER SUBSTUTIONS SHALL NOT BE MADE WIO PRIOR WRITTEN APPROVAL FROM ENGINEER. -ALL EXT. SMS (DECKS, ETC.) SHALL BE EXT. GRADE & SHALL BE CLEARLY MARKED. - SEE S-001 FOR REQUIRED BEAM GRADE. -1 FLOOR FRAMING PLAN NOTES I I A. DETAILS ARE NOTED ON THE PLANS IN TYPICAL LOCATIONS AND SHALL BE REPEATED WHERE SIMILAR CONDITIONS EXIST. SEE TYPICAL DETAILS AND GENERAL NOTES. B. SEE STRUCTURAL DETAIL SHEETS (S-SXX) FOR STRUCTURAL NOTES & DETAILS. C. P E 2 STUDS MINIMUM AT ALL BEAMS, HEADER13 AND GIRDER TRUSS BEARING POINTS WITH SPANS GREATER THAN SIX FEET, UNLESS NOTED OTHERWISE. MULTIPLE STUDS AND COLUMNS SHALL ONTINUOUSTO FOUNDATIONOR SUPPORTING BEAM BELOW. USE MULTIPLE SOLID BLOCKING AT FLOORS. D. SEE FLOOR SHEATHING NOTES FOR FLOOR SHEATHING SIZE & NAILING. E. AT FLUSH BEAMS USE SIMPSON LBV SERIES (WEB JOISTS) OR JB SERIES (WOOD JOISTS) TOP FLANGE JOIST HANGERS EACHJOIST U.N.O. F. ARRANGE JOIST LOCATIONS AT BATHROOM AND KITCHEN AREAS TO AVOID CONFLICT WITH PLUMBING. G. FLOOR JOISTS UNDER FIREPLACE HEARTHS MAY NEED SPACING REDUCED AND/OR SUBSTiTUTEDWILVU.TO SUPPORTTHE ADDED LOADING. VERIFY W/ ENGINEER. H. HOT TUBS OR OTHER OWNER INSTALLED I r T =MS THAT IMPOSE HEAVY LOADS ON ... _ U_L MEMBERS WILL REQUIRE ADDITIONAL ENGINEERING IF NOT SHOWN ON ORIGINAL PLANS USED FOR DESIGN. STRUCTURAL MEMBERS MAYNEEDTOBE INCREASED FOR THE ADDITIONAL IMPOSED LOADING. 1. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL HE PRESSURE TREATED LUMBER OR FOUNDATION REDWOOD. ALL WOOD SUPPORT MEMBERS EXPOSED TO WEATHER SHALL BE TREATED OR PROTECTED TO PREVENT MOISTURE OR WATER ACCUMULATION ON THE SURFACE. FLOOR SHEATHING A. TYPICAL FLOOR SHEATHING SHALL BE 3/4 IN., T&G APA RATED 4824 EXPOSURE I SHEATHING NAILED WITH 8d RING SHANK NAILS AT 6 IN. D.C. AT ALL PANEL ENDS ' SUPPORTED EDGES, TOP OF SHEAR WALLS (ALL EXT RIOR WALLS ARE SHEAR WALLS) AND ALL BLO KING; Ild AT 12 IN. D.C. ALONG INTERMEDIATE FRAMING MEMBERS. NAILING SHALL BE SPACED AT 3/8 IN. MIN FROM EDGE OF PANEL. B. LAY SHEATHING W TH FACE GRAIN AT RIGHT - ITF ANGLES TO FRMG Wl END JOINTS STAGGERED (SEE TYP DETAILS). C. BLOCK JOISTS SOLID AT ALL BEARINcRE mt> % Hdium AE STRUCTURAL ENGINEERING &35 WEST 5300 SOUTH, SUITE 203, SALT LAKE CITY, LIT 84123 PHONC-.(801)974-5101 FAX'. (801) 974-5102 1-01. POPE REMODEL 18209 76TH AVE W EDMONDS WA TIEK DESIGN GROUP I ..Ea nIE: I SECOND FLOOR I FRAMING PLAN I DESIGN TEAM GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS 908' 'REGISTERED I ARCHI CT I e ML, . '0] M MLY C. ANGUM 0 0, F WASHINGTO STBUCTI MAL ONLY COPYRIGHT- ALL RIGHTS RESERVED 078COMIGH- USEMRREPMOUCMN ­O­ENPFWISSI0NONLY Co ­y: ARK, BBJ 1%ft ­__ GEJ, ALG C4 1 ­-OCT 15, 2019 co IILOTOA�: Oct 16. 2019 3:28p. S-102- 'PERMITSET BLIW%EIlll .,W.TN ROOF FRAMING PLAN 01 4' 10, 16 EXTERIOR WALL FRMG SCEHDULE] WALL STUD LUMBER PERP. PARA* TYPE S GRADE FRMG 2X4 IV' DOUG FIR _FRMG 8'4' W-W 2X4 IZ' DOUG FIR W-V iv-0" 2xS IS' DOUG FIR 14W" W-W 2.6 12' DOUG FIR 16-V IV-&' 1-31,V'x 5-la" IV 1.55 E LSLI IV­V LSL STUDS 1-31W'x 5-11Z' LSL STUDS lr 1.55 E LSL lv-w 16-T DBL 2x6 DOUG FIR IV-&' 18'-W DBL LSL �16.t IV' 1.65 E LSL IV_(yl iw-v LSL 7-1/4" 161, 1.65 E L LS LSL 20'-V 20-Y' NOfii. TABLE DESIGNED FOR 115 MPH EXPOSURE'C' 50 PSF FLAT ROOF SNOW LOAD FRAMING PERR TO WALL SHALL NOT EXCEED ".. SPAN. CONTACT ENGINEER FOR MAX H OF STUDS SUPPORTING LONGER SPANS THAN 4;_o MAX HT, REFERS TO UN -BRACED WALL HEIGHTS. FULL HEIGHT STUD WALLS WHICH ARE EIRACEDLATERALLY (TRUSSES OR RAFTERS) WA I HEIGHTS MAY BE REDUCED TO THE POINT AT WHICH THE FIRST LATERAL BRACE OCCURS. SPECIAL STUD SPACING CONDITIONS TO BE S NOTED ON FRAMING PLANS. I —DF') POST SCHEDULE ARK DESCRIPTION GRADE/ NOTES DF-2 1(2) STUDSITRIMMERS DF#2 OF-3 ) STUDSITRIMMERS DF#2 DF-4 (4) STUDSrrlRIMMERS DF#2 DF-4.4 4x4 POST or DF-4.6 4xSPOST _DF#I DF#I a BTR DF-6.6 GxSPOST DF#1 or BTR TS4.4 HSS4x4xlle A600-GR.B-46 NOTES: POST SIZE IS MINIMUM REaD. SIZE & GRADE MAY BE INCREASED FOR ARCHITECTURAL DETAILING OR CONTRACTOR PREFERENCE. ADDITIONAL STUDS TO BE USED UNDER WIDE BMS TO PROVIDE FULL BM BEARING ALL BUILT UP POSTS SHALL BE BUILT FROM STUDS TO MATCH WALL THICKNESS. KEYED NOTES I. GIRDER TO SUPPORT EXISTING TRUSSES IROOF BEAM SCHEDULE I MARK ISIZE RB-1 (2)-2X8(8) I Rp -21(2) l-W4"XII-7 RB-3 0 I-W4' X 9-111, KEY'. 1. HEADER 2. FLUSH IN ROOF 3. SLOPED WITH ROOF 4. CANTILEVER END OF BEAM 5. T.O. BEAM - B.C. TRUSSESIJOISTS NOTES: - DEEPER ANDIOR WIDER MEMBERS MAY BE SUBSTITUTED OF SAME GRADE. OTHER SUBSTITUTIONS SHALL NOT BE MADE W10 PRIOR WRITTEN APPROVAL FROM ENGINEER. -ALL EXT. BMS (DECKS, ETC.) SHALL BE EXT, GRADE& SHALL BE CLEARLY MARKED. HEADERS <'-O" WIDE @ GABLE END WALLS ARE NOT REQUIRED WHEN STRUCTURAL GABLE TRUSSES ARE USED. SEE S-OD1 FOR REQUIRED BEAM GRADE. ROOF FRAMING PLAN NOTES A. DETAILS ARE NOTED ON THE PLANS IN TYPICAL LOCATIONS AND SHALL BE REPEATED WHERE SIMILAR CONDITIONS EXIST. SEE TYPICAL DETAILS AND GENERAL NOTES. B. SEE STRUCTURAL DETAIL SHEETS FOR STRUCTURAL NOTES & GENERAL USE DETAILS. C. SEE DESIGN PLANS FOR DIMENSIONS. DO NOT SCALE STRUCTURAL DRAWING$. D. SEE TRUSS NOTES FOR ROOF TRUSSES LOADING AND SPECIFICATIONS. SEE ROOF St SHEATHING NOTES FOR ROOF SHEATHING SIZE & MAILING. BOTH ON 8.001 E. PLACE 2 STUDS MINIMUM AT ALL BEAMS, HEADERS AND GIRDER TRUSS BEARING POINTS WITH SPANS GREATER THAN SIX FEET, UNLESS NOTED OTHERWISE. MULTIPLE STUDS AND COLUMNS SHALL EXTEND CONTINUOUS TO FOUNDATION OR SUPPORTING 13EAM BELOW. USE MULTIPLE SOLID BLOCKING AT FLOORS. F. COORDINATE ALL TRUSS CONFIGURATIONS W/ DESIGN PLANS. SEE ROOF TRUSS NOTES. G. OVER BUILT AREAS ARE SHOWN SHADED. SEE OVER BUILD DETAIL(S). H * ALL TRUSS RANGERS TO BE SPECIFIED BY TRUSS MANUFACTURER. X z 0 z------- d Iridium AE STRUCTURAL ENGANEERING 635 WEST 5300 SOUTH, SUITE 203, SALT LAKE CITY, UT 84123 PHONE: (801) 974-5101 FAX.. 1801) 974-5102 P-1 POPE REMODEL 18209 76TH AVE W EDMONDS WA TIEK DESIGN GROUP ROOF FRAMING PLAN DESIGN TEAM LEAD: GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS ED Amw"'T, 8 U, 16 2019 G DEPARTMENT RESERVED D— ` ARK, BBJ CHECKED- "-GEJ, ALG IME DATE: NOV 512018 co Nm 05, 2018 3:54pm EHEETN.- -'7A— -103 __ PERMIT SET MAIN FLOOR SHEAR WALL PLAN 01 2 16, 20' UPPER FLOOR SHEAR WALL PLAN 1/8"=11-0.. ___ - - __ - L i , 3'2' 0. 2' 81 16' 20 KEYED NOTES 1. WALLS REMOVED ASSUMED TO BE NOWBRG.] CONSULT EOR IFWALLS ARE BEARING I ISHEAR WALL PLAN NOTES A. ALL HD AND ST CALLOUTS SHOWN SHALL BE INSTALLED AT BASE OF SHEAR WALL SHOWN 13. SEE SHEAR WALL NOTES AND NAILING REQUIREMENTS ON S-001 C. DETAILS ARE NOTED ON THE PLANS IN TYPICAL LOCATIONS AND SHALL BE REPEATED WHERE SIMILAR CONDITIONS EXIST. SEE TYPICAL DETAILS AND GENERAL NOTES. D. SEE STRUCTURAL DETAIL SHEETS (S-SXX) FOR STRUCTURAL NOTES & GENERAL USE LS. E. SEE DESIGN PLANS FOR DIMENSIONS. DO NOT SCALE STRUCTURAL DRAWINGS. F. .,STRAP OPENINGS" INDICATES PERFORATED SHEAR WALL THAT REQUIRES STRAPS AT OPENINGS. SEE SHEAR NAILING ON S-001. <�> F- STRAP TIE SCHEDULE RK TIE TYP LOC I "" TENSION (LBS1 FAOTF*NER5 I RF0UIRFn NOTES ST-1 CS16 FLOOR TO FLOOR 1705 (20) 10d IVENDLENGTH ST-2 C814 FL02E LO EL02E Ng� (26) 10d 15" END LENGTH E OR To FLOOR 524 (40) 16d F OR TO FLOOR 56405 (14)I14"x2-I/Z'SD$ V'MMBR REOI) ST4 HDU8 FLOOR TO FLOOR 6766 (20) IW x 2-1/r SIDS T'MMBR REUD HOLDOWN SCHEDULE MARK MODELN ME MIN MEMBER A.& A.U. MAX MBERTHK FASTENERS DIA EMBED(tc) LOAD(LBS) HD-1 DTTIZ 1-112" (8) 1=1-11r 3/8' W. 910 HD-2 DT72Z 3" (8) SDS 1/4'XI-1/2' 1/2" 61 2145 LSTHD8 (RJ) 3" (16)16dSINKERS 1610 HD-3 HDU2-SDS2.5 3" (6) BIDS VWX2.!M" 5181 ir 3075 STHD10 (RJ) 3' (20) 16d SINKERS 2175 HD4 HDL_ SD(S 1" (10)SDS11WX2-Iff' 11. 12' 6 ST. D14 3' (24) 16d SINKERS 3 N 1�1 HD-5 HDU&SDS2.6 3" (14) SCIS 1XX2-Ia' 5/w. 12" 5645 3- (20) SDS VWX24/2 7/9' il S� 6765 HD-7 HDU1I-SDS2.5 5-1W (30) SDS 11,V'X2-112 V is" 9335 NOTES: ALL HOLDOWNS ARE SIMPSON BRAND. EQUIVALENT STRENGTH HID MAY BE USED. STRONGER HOLDOWN MAY BE USED; HD-2 MAY BE USED IN LIEU OF HD -I MULTIPLE OPTIONS FOR HD-X ARE SHOWN TO ALLOW CAST IN PLACE OR POST INSTALLED HOLDOWN (RJ) INDICATES USE OF STRAPS AT RIM JOIST APPLICATION. NOT REQI) FOR ALL APPLICATIONS VALUES SHOWN FOR TENSION ARE FOR 8" MIN FDN WALL THICKNESS. I> I SHEAR WALL SCHEDULE MARK SHTO NAILING STAPLES — A'B* I SOLE PLATE NOTES I —ED—GE—s T sizE I EDsEs I FIELD SPCG TO RIM JST SW-1 7116" 8do(M S!, ' 2X .0 Ir O.C. led (g w O.C. 16"S IY27 W. o-C. OT.UDSfi C.M ESW2 Sd 4" 16d @ W' O.C. 2X STUEM S 7116! 0% 12"O.C. %" 25'O.C. 8"O.C. 3Z'O.C. 16 O.C. A SW_ SW-3 7116. 8d 3" - O.C. 3X Ds 12"O.c. IV r O.C. 8"O.C. 32* O.C. 16d@4 PA STU NEL ED S SW_ SW-4 7/16" 8dQr 16d @ 3. O.C. 3X DS P_ O.0 Ir O.C. 24"O.C. PASTU NELEDG%S SW-5 15132., 1OC122" 12- O.C. DO NOT USE STAPLES 16- O.C. 16d @ Z'O.C. 3X STUDS @ 0 — PANEL EDGES1 iz, O.C. Bd 7 6 NOTES: -ALL SHTG TO BE APA RATED JIBOTH SIDES" INDICATES SHTG IS REQUIRED ON BOTH SIDES 0 F WALL 's; � D, S M* A**Y' BE` R* E, P, L-A*C-E-D * W"i-D SL. *2-X "S T" U DS* S, T-1 T _CH- N*A­ I *L-ED,- z 0 J, '11.,� 'It1q, .............. Iridium AE STRUCTURAL ENGINEERING 635 WEST 5300 SOUTH, SUITE 203, SALT LAKE CITY, UT 84123 PHONE: (801) 974-5101 FAX. (801) 974-5102 POPE REMODEL 18209 76TH AVE W EDMONDS WA TIEK DESIGN GROUP ­ETTITLE: SHEAR WALL PLANS DESIGN TEAM LEAD, GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS , W"TNOT WTC —.A EEURCTLIRAL ONLY W 16 2019 LN2M 5NT j,.00P.y,R1,G,CT - _A1L.1.1ft`TS.R&1MD V PROR ��EN PERM-iSSION ARK, BBJ ,CHECKED BY' GEJ, ALG lc�l ME —NOV 5, 2018 PLOT— Nw 05, 2018 3:54Pm E -ET S-104- PERMIT SET z 0 J, '11.,� 'It1q, .............. Iridium AE STRUCTURAL ENGINEERING 635 WEST 5300 SOUTH, SUITE 203, SALT LAKE CITY, UT 84123 PHONE: (801) 974-5101 FAX. (801) 974-5102 POPE REMODEL 18209 76TH AVE W EDMONDS WA TIEK DESIGN GROUP ­ETTITLE: SHEAR WALL PLANS DESIGN TEAM LEAD, GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS , W"TNOT WTC —.A EEURCTLIRAL ONLY W 16 2019 LN2M 5NT j,.00P.y,R1,G,CT - _A1L.1.1ft`TS.R&1MD V PROR ��EN PERM-iSSION ARK, BBJ ,CHECKED BY' GEJ, ALG lc�l ME —NOV 5, 2018 PLOT— Nw 05, 2018 3:54Pm E -ET S-104- PERMIT SET DESIGN TEAM LEAD, GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS , W"TNOT WTC —.A EEURCTLIRAL ONLY W 16 2019 LN2M 5NT j,.00P.y,R1,G,CT - _A1L.1.1ft`TS.R&1MD V PROR ��EN PERM-iSSION ARK, BBJ ,CHECKED BY' GEJ, ALG lc�l ME —NOV 5, 2018 PLOT— Nw 05, 2018 3:54Pm E -ET S-104- PERMIT SET FOUNDATION SCHEDULE UTAH AMENDED FDN SCHED TOP EDGE SUPPO FOUNDATIONWALL REINF STEEL FOUNDATI REINF STEEL FLOOR or ROOF MAX HEIGHT THICK VERT I HORIZ MAX HEIGHT THI K VERT KORIZ F ING DIAPHRAGM NO TOP [6" MIN #4 @ 32" (2) #4 TOP EDGE 8" MIN 1 #4 @ 16" 1#4 @ IZ' 2' EDGESPIRT #4 @ 24" (4) #4 T.O. FQN :OMNT PRESSURE 41 6" MIN -71i-.�-SUPPORT SEE RETAINING WALL OTIS 6' GE " MIN #4 @ 24" (5) #4 TREATED SILL PL ...... , TOP CRAWL #4 @ 16" #4 @ 12" ED , 9-*�- j , 0 TED SPACE -111-111- 91-10, w 8" MIN #4 @ 12" #4 12" (6) #4 7.CK HORIZ REINF - w FILL I I-BACK-11 (1) BAR WAN TOP 4". 'T- #5 @ 12" #4 IV' (1) BAR W/IN OT 4". #4 @ 6" #4 @ 12" NOTES: TO USE ummAm­ S 8" MIN OTHERS@ ED SPACE 1. BACK FILL SHALL BE SOIL CLASS, TYPE GW, GP, 9]- - #4 @ lV1 SW OR SP, PER IBC TA13LE 1810. 1, CLEAN GRAVEL, =1 I L��nI �,,r =� I VERT REINF - #5 @ 12" lz 1011MIN #5 @ V #4 @ IV' SAND, OR GRAVEL -SAND MIXES, WELL OR PnnRI Y @ CTR OF WALL EXTEND 112' SEE TALL FDN RACED. BACKFILL CANNOT, BE CLAY OR CLAY MIXES. w DETAILS MAY NOT BE USED WHERE THE DIFFERENCES IN TO WAN 3" (MAX) 1 Y? (Mil' REINF FREE STANDING FDN (NO BACKFILL 2 NO TOP EDGE SPIRT 6RADE FROM ONE SIDE OF STRUCTURE TO THE OF TOP OF WALL .EITHER SID= EQUALLY BACKFI1 I ED OTHER IS MORE THAN 5 FT. T,O. FD EA SIDE SA TYP MAX HT FWI kL OF LOCAL BUILDING OFFICIAL REDD. OWLS TO NOTES: - - - - - - - - - - - - - MATCH VERTS �RA` .PA1 1. BASED ON 3,000 PSI CONG AND 60,000 PSI FDN b NOTESAPPLICABLETO RE 7E.K � 3 IMF. - - - - - - - - - FILL ALL THREE SECTIONS Ir -"STEP '�Z� �F NSET SILL PL & FRIAG FOR MIS VENEER. II- HERE' T. FDN w I T.O. DWIL WID ER FDN THICKNESS REDD FOR �4" MAS m ` I T*" .FDN VEN ER LEDGE. T. of 4" MIN SLAB 3. SILL PL SHALL BE FASTENED W/A.B. AS m - ICKNESS P m - GRADE LAB ON GRADE INDICATEDIN LAN& SHEAR WALL SCHEDULE. ff E1:1 :I T 6 FT u SEE FDN & SILL P E NOTES. L 4. RETAINING WALLALT U- K 11) MAX I TYPE FTG & FON MUST BE ji. (BAC mi IT mA T.O. SLa J.-Til Hit ! 1�r�m I T.O. FTG _f INSTALLED WHERE TOP OF FDN IS NOT SUPPORTED W1 FLR OR ROOF DIAPHRAGM. FDN' 9"X20" MIN w/ (2) #4XCON RETAINING WALL FDNS REQUIRE: WIDER FTGS, EDULE ADDL REINF & SPECIAL PLACEMENT OF REINF MINZ-V'X SECTIONS SEE PLAN & SCH & DI RECOMMEND THAT FDN WALL CONT FTG OUNUATION REINFORCEMENT MAINTAINS FULL HT UN IL MAX HT OF BACK FOUNDATION ELEVATION FOUNDED BELOW NO SCALE FROST DEPTH THIIS -L - RESID-AL CONVRU=ON ONIN SOLID BLOCK ALL POSTS FROM 10d.NAIL l6d @ 6" O.C. (MAX) PL TO RIM JST INTERFERING D . LOTS &PIPING ABOVE TO BEARING BELOW T& RIM JST SEE SHEAR WALL SCHEDULE SOLID COMPOSITE RIM JST DBL TO JST 2x STUDS @ le. O.C. (TYP) M'i�j RIM JET OR 2X4 "SQUASH BILKS" 2X4 FLAT NAILERT&B REQD FOR THREE STORY PERIMETER NAILING ALT BLOCKING WOOD WST - (SEE PLAN) W/ (2) 8d TO SILL PL EACH JST TYP ALL BEARING POINTS SOLID WST BLKG 0 3Z' O.C. PERP TO RIM JST @ 1ST (2) JST BAYS W/ (2) 10d TO SILL PIL & 8d @ 4" D.C. FLR SHTG TO BLKG - SEE BLOCKING PLAN- NOT REQD AGAINST GARAGE NO NAILS CLOSER THAN 1)/2" FROM LAP EXT SHTG OVER JOINT BETWEEN PLATE & RIM END OF JST - NO OR ATTACH SOLID COMPOSITE RIM JST W/ 16d COM - DRIVE SIMPSON LTP4 @ 24�' D.C. OR WST RIM W1 1 Od @ NAILS@ ANGLE 2,V'O.C. EACH SIDE (I-JST RIM SHOWN) BAR LAP ev, MIN 24" MIN EMBED OWLS TO MATCH HORIZ FDN REINF EXISTING FDN & FDN NEW FTG (2) OWLS MIN TO EXISTING FTG N . D 11E P-1- THE �p T F MIN MEMBER THIC NESS 14 P R HOLDOWN SCHEDULE NEW FDM -t- EXISTING FDN NOTES: 1. NeW FTGS & FDNS SHALL STEP DOWN TO MATCH BEARING ELEV OF EXISTING UNLESS NEW FTG & FDN IS LIGHTLY LOADED ((I) STORY MAX). 2. WHEN NEW FTG IS DEEPER THAN EXISTING, FOR FROST DEPTH, ETC. NEW FTG SHALL UNDERCUT I SUPPORT EXISTING FTG APPROXIMATELY 4". A .... ...... �IT'TJN, G­ H*CLE-0* R, -INS T*A*L'L­W'1`EPO*X*Y,' 4. AT NO TfME SHALL EXIST. FTG & FDN BE UNDERCUT IN A MANNER THAT EI . M.-IN LL WILL CAUSE INSTABILITY W/O ADEQUATE TEMPORARY SUPPORT. F, PSONSSTB.ASTM 554, THREADED ROD W1 (2) NUTS & WASHER. NEW FTG & FDN TOEXISTING (�r�� BE HOLDOWN SCHED ) FOR SIZE A D EMBED. NO SCALE k 4 ) IR SIZE A 48" MIN TOP PL SPLICE \_16d 0 470 STAGGERI (2) 16d EACH SIDE OF BREAK IN T&S PL TOP PL SPLICE NOTES: 1. INSTALL SIMPSON STS236 WHERE TOP PL SPLICE IS NOT IT INSTALLED AS SHOWN 2. SPACE SPLICES 8�0"MIN APART COL TOP PIL CORNERVION CORNER VIEW -ie-CORNEROR F- JOG IN FDN ZXCONT PRESSURE IL BLOCKING PLAN NOTES: SIMPSON ITS TYPE TOP R ALUMINUM FLASHING - PROVIDE l.SEEFDNWA1­L&FDN >rHINFOET FLANGE JST HANGER DRIP LEG @ EXTERIOR 8 Y2 2. DIMENSION LUMBER IS NOT SUITABLE WOIST FRAMIN FDN . . . . . . FOR USE AS RIM BOARD Wt WOOD- I JOISTS -SEEPLAN CONCFDN NO SCALE A BEAM TIE LOCATIONS 5- 14" MIN EDGE DIST. (TYP) NOTES: 1. ALIGN TIES Wt END STUDS, WINDOW I DOOR OPENING TRIMMER& SEE PLANS FOR LOCATIONS. 2. ALTHOUGH DIMS MAYBE GIVEN ON PLANS FINAL PLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR. 3. TIES MAY BE INSTALLED OVER SHEATHING. 4. SEE STRAP TIE SCHEID FOR SIZE & RECID FASTENERS. 3X OR 4X POST OR (2) -1 ZX STUDS Wt 1 Od @ 8" O.C. EACH FACE FULL HEIGHT TYP TIE CONNECTOR SEE PLAN & SCHED. FLOOR SHEATHING THREADED ROD el... FOR HTTS) DBL RIM JOIST OR ADDED SOLID BLOCKING @ TIES SEND TIE UNDER & ONTO BACK FACE 7MIN FULLY NAIL W/ 10d DR TIE /b NO SCALE k LAP TOP PL OR SIMPSON 1212L a CORNER MIN 318!'WOOD STRUCTURAL PANEL VVI Sd @ 3" O.C. - (2) ROWS STAGGERED EACH SIDE VERTICAL LEG, SILL PLATES, & PANEL JOINTS OF PORTAL FRAME AT CENTER PIERS INSTALL CS16 STRAPS ON BOTH INT & EXT FACE OF WALL SIMPSON CS16 COIL STRAP X 24" MIN W/ (13) 8d MIN EACH END OVER OR UNDER SHTO @ INSIDE OR OUTSIDE FACE OF WALL NAIL TOP PIL TO BOT OF BM W/ (2) ROWS 16d SINKERS @ Y 0 - C - STAGGERED MIN HEADER T'X`11-114�' (NET) 3X MIN POST OR (2) 2X STUDS - FACE NAIL W1 10d @ 8" O.C. EACH FACE FULL HEIGHT (2) 2X BLKG @ HORIZ JTS- FACE NAIL W1 10d @ 8" O.C. EACH FACE FOR ADJACENT IN -LIME DOORS AT CENTER PIER, BREAK SHORT SPAN DOOR NOR @ TRIMMER STUDS & ADD 2ND COIL STRAP GARAGE PORTAL FRAME HDRI/-,= NO SCALE \1� 8 = BEST PRACTICE EXTEND LEDGER BOLTS THRU MASONRY VENEER WHERE APPLICABLE INSTALL MIN (3) PER DECK, SIMPSON DI I slog F WR S V01 IMPSON SDS 1/4 x 3-l/I 6" D.C., L NOR STAGGERED TOP & BOTTOM TO RIM ROIST. V NOTCH RG WALL DECK JST W/ SIMPSON ITS HGR IN DECKING IF e > 2d ADD 2nd TIE JST TO SIM W/ SIMPSON PAIR OF BRACES HI OR H2.5 @ 48" OC MAX d e BRACE T.O. JSTS W/ CS16 NOM BRACING W1 (2) 10d MIN @ EACH JST NOT REDO WHEN DECK HAS SH DECK BRACING PLAN HOUSE DECK LEDGER NO SCALE r �A­­­ FULLY SHEATH ---%, SOLID BLKG @ 8-4- MAX LOW ROOF MAX SPA 2X6 OR 2X8 JOISTS @ 24" O.C. PERIM NAILING 2X PONY WALL CONT, FULL WIDTH OR MLTPI­ ACROSS TRUSSES OR ZX "KICKERS!"AY PLYIND ZX CONT PLATE(S) GUSSET ATTACHEMENT UNDER HEEL & TOE TO OVERBUILD JST. OVERBUILD JIST EXTEND TO LOW TRUSS LOWROOF PANEL POINTS TRUSSES FULLY SHEATH LOW ROOF ROOFSHTG PERIM NAILING FULLWIDTH RMLTPL2XCONT PLATE(S) UNDER HEEL & TOE_ LOW ROOF TRUSSES TOE NAIL W1 (3) 8d MIN jCWROOF USSES MOTE: FOR OVERBUILD RIDGE & HIP BUS USE (1) MSR ONE SIZE LARGER FOR SNOWILOADS . 100 PSF BUT � 200 PSF USE 2xl2s @ 24"O.C. FOR OVERBUILD. ROOF OVERBUILD NO SCA SHEAR WALL SHTG CONT TO HIGH ROOF FROM FDN OR FLR FRMG BELOW 2x BLOCKING 8d@4-OC 2X CONT LEDGER W/ (2) 1/4!'x 4.1/Z'SDS SCREWS @ EACH STUD . -� 2X NAILERS @ V-O" O.C. W1 (3) 1 Od'S @ EACH PARALLEL TO WALL END - ALIGN W1 STUDS ;............................. d @ 4" O.C. ZX CONT LEDGER W/ (2) 1/4" x 4-10 SDS SCREWS @ EACH STUD FUR FRMG & SHTG SEE PLANS & NOTES LOW ROOF TRUSS -SEE JST HGR EACH TRUSS - INSTALL SOLID PLAN BLKG WHERE REDD - SPECIFIED BY TRUSS MFR LOW SHEAR WALL OR SUPPORT BEAM (SEE PLANS) PERPTOWA" LOW ROOF @ SHEAR WALL M NO SCALE THIS - FOR RESIDE- C­ ONLY SOLID BUNG REGO III HOLDOWNS ND_5 ANDI­AROER WALLA CHORI* .. ........ (2)112 BOLTS OR TITEN HD(INTE IOROR EXTERIOR OF FDN WALL) ................... INSTALL�TI2,N s E 5 %­.bl= I(J.1 PIPE & STRA "PLWIDTH 6d EKAAFEbND) i NONE, S UPSON STRAP EACH SIDE ,. W TOP PLATES S L L DRILLED AND N ED DEIL TOP P WHENEVER POSSIBLE TYP WALL STUDS VERIFY SIZE & LOC C PIPE W/ ARCH., MECH. & ELEC. DRAWINGS TOP PIL SPLICE 0 PIPE - - - - - - -i-qO4,96JOISTS - ;6; w-AM­GES*1;8" WOOD - I BUKG OR 2X BILOCKS W' TALLER THAN JOISTS) REQD 0 INT WALLS W/ LOAD BEARING WALLS ABOVE WOOD - I BLKG REQD @ INT S.W. - WOOD - I BLKG NOT RECID OVER INT BRG WALLS W! NO BRG WALL ABOVE NOTE: CONTRACTOR SHALL FOLLOW ALL INSTALLATION GUIDELINES OF ENGR WOOD PRODUCTS MFG 2x STUDS @ IS' D.C. (TYP) SEE ADDITIONAL NOTES ON INTWALL WOIST FRAMING@ PON DETAIL I -JOIST FRAMING Q FRAMED WALLS NO SCALE -M-5 PERIMETER ROOF SHTG NAILING 10d @ 4" O.C. 2x4 SLKG W1 (2) 16d )4 FIVE PER DESIGN DWGS 2x4 @ 24"O.C. MAX D @ EA CH EN, GA13LE END TRUSS W/ VERT (6) 16d WEB MEMBERS 0 24" D.C. MAX MIN 1 BRACE - 2x4 VERT DIAG A34 EACH SIDE OF BRACE SHEATHING W/Y." GAPS A INDICATES PERIM SHTG NAILING SEE S.W. SCHED WHEN BRACE LENGTH EXCEEDS 6`0" ADD 2x4 (FLAT) & NAIL W1 l6d ji 8" D.C. OR NAIL BRACE TO TRUSS WEBS SECTION A T.O. GABLE END WALL TO SLOPE TO MATCH BOTTOM CHORD OF TALT D.C. tj SCIS OR TRUSSES. SRACE BRACE I ALT (K-BRACINGI 2x4 HORIZ DIAG - INSTALL BRACE ON T.O. BOTTOM CHORD W1 (2) 16d @ EA. END & EA. TRUSS- INI LTERNATE B ICING w AS VERT BRACE MAX S, IF IF v h w -, , , . r T IF 2x4 NAILER W1 A34 EACH SIDE TO TOP PLS 2V- GABLE WALL (5) OR MaBBLMCEES (3)BRACES (1)BMCE __.@ G E No BRACE SPACING NO SCALE 'LE WOOD-1 JSTS WITH SOLID BLOCKING BETWEEM JOISTS REDD W? BRG WALL ABOVE WOOD-t JSTS WITH SIMPSON MIT JOIST HANGER EACH JOIST - SEE PLANS FLUSH FRAR SHOI INSE MAS( VENE (2) 2X STUDS - FACE NAIL W1 I Od @ 8" D.C. EACH FACE FULL HEIGHT MIN /8" WOOD STRUCTURAL PANEL W1 8d @ 3" O.C. - (2) ROWS STAGGERED EACH SIDE VERTICAL .EG, SILL PLATES, PANEL JOINTS )F PORTAL FRAME �IMPSON STHD14 HOLDOWN AT ACH END OF PORTAL FRAME �EE FDN & SILL PLATE NOTES !ECESS T.O. FDN & INSTALL ,ONT FTG @ DOOR OPENINGS NOTES: 1. SEE FTG & FDN PLAN & DTLS FOR REINF 2. H.D.'S MAY BE INSTALLED OVER SHEATHING. GARAGE PORTAL FRAME @ FOUNDATION,/-, HIS -FORRESID-CONSTRUCTIONIONLY NO SCALE k I SA- SIMPSON C814 X SIM WIDTH 132" W/ (15) 10d EACH END BACK SIDE l6d @ 3" O.0 *""MULTI EACH SIDE STAG13ERED USE SIMPSCN SC-­� I y I FULL HT W(POSTII BOVE STUDS EACH SIDE SIMPSON CCO -STUDS OR POST SIMPSON ACE NOTES: 1. SEE PLAN FOR BEAM, COL & POST SIZE & LOCATIONS. 2. ALTERNATE COL CAPS & MANGERS MAY BE USED PROVIDED THEY ARE RATED FOR REDO LOADING. EQUAL fy CONNIS FROM OTHER MFG. fop MAY BE SUBSTITUTED. 05f 5 3. SHOP FABRICATED CONN M B 501, VA 10,01 USEDASALTTOT BE H 601014 SHOP DWG & EN E IE REC oAP' CINSTALLALL STENERSPE MFG. SPECS. WOOD BM TO WOOD COL S. CONTRACTOR TO COORDINA I IE ALL FINISH BRG ELEV & SIZE If DIMS OF MEMBERS & CONNECTIONS. >NSTAUL SIMPSON CSISX2,V Wt (11) IDd EACH END WHERE BEAMS WOOD BEAM /C,OLUMNr, SPLICE @ COLUMN CONNECTION. NO SCALE NOTES: INSTALL FULL HT SOLID 1. ROOF SHTG NOT SHOWN. SEE ROOF BLKG BETWEEN EACH SHTG NOTES FOR SIZE & NAILING L TRU S BLKG MAYBE -gT � N E ED OR DRILLED FOR VENTILATION ROOF SHTG TO BLKG IPERIM NAILING) hjiL/___NAIL NAIL FASCIA TO EACH TRUSS ­W/ (2) 1 Od MIN rd F�F*;RiJ;; SHOWN) SEE ROOF FRAMING PLAN _ GUSSET PIL NOT SHOWN FOR CLARITY STUD WALL OR SIM TYP NOM SEE HIGH TRUSS BLKG DETAIL WHERE TRUSSHEELHT�12" DBL TOP WALL PLATE SIMPSON HI @ 48" O.C. (INSTALL@ EA. TRUSS WHERE WIND � 150 MPH & NOTED ON PLANS) OR H2.5A AT EA. TRUSS HI HURRICANE TIES SSjfAMING rU NO SCAIrA I I .­��;..� ................................ C. STAGGERED STEEL BEAM PER PLAN 1/4" WEB STIFFENER REQUIRED AT BEARING. ONE SIDE ONLY 2- (2) 5/8' BOLTS 4"(W)x8"(H)xl/4" STEEL PLATE WELDED TO U/S OF BEAM COL. PER PLAN OPTION I 2x PLATE TOP & BOTTOM W/ 1 121, STUD G 24" O.C, STAGGERED BUIU Cr 114!'WES STIFFENER REQUIRED AT BEARING. ONE SIDE ONLY STEEL BEAM PER PLAN NOTE: TYP CAL TOP PLATE ON STEEL BEAMS: 2X (BEAM WIDTH) X CONT T.. . . ............ fN.T MAXIMUM 1/4" OVERHANG PERMITTED. OPTION 2 JOISTS TO STLLEBEEALM % REFER TO DETAIL BIS-501 (y FOR STRAP REQ'D NO SCALE\ y WHERE BEAM IE `,QNTERRUPTS TOP PLAT Ls- x 4" LA G BOLTS COL. PER PLAN POSTS f NO SCALE 0 CD LU 0 0 z Of Iridium AE STRUCTURAL ENGINEERING 635 WEST 5300 SOUTH, SUITE 203, SALT LAKE CITY, UT 84123 PHONE: JODI) 974-5101 FAX:(801)?7"102 P-T: POPE REMODEL 18209 76TH AVE W EDMONDS VVY TIEK DESIGN GROUP SHEETTITLE STRUCTURAL DETAILS AND NOTES DESIGN TEAM LEADS GARRETT E. JENKINS AUSTIN L. GREER ROSADER KINGSTON BRADEN JENKINS STRUCTVRAL ONLY IrEPARTMENT EMONDS COPYRIGHT - ALL RIGHTS RESERVED 1mcomIoNTAOT, US-R."I"T" �PFNOR ­7EN FERMISSION ONLY 0 "'y: ARK, BBJ 1%ft CHECKED BY. GEJ, ALG C� """A"NOV5,20118 00 PLOr­ mar 20,2019 9:18am SNI S-500- US PERMIT SET