Loading...
BLD2019-0189of E DV CITY OF EDMONDS 121 5TH AVENn NORTH - EDMONDS, WA 98020 PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 07/01/2019 Pennit#: BLD20190189 Expiration Date: 01/01/2#20 /' v Project Address: 650 BELL ST, EDMONDS Parcel No: 0043420980170/ VONS BELL ST AD SHAP I RO ARCHIT ECT S P S PAUL JENSEN EXCAVATING C/O GOEDERT CHARLES VON 1207 N. 200 ST CIO PAUL JENSEN 440 12TIi PL N SHORELINE, WA 98133 21 CRESSEY LN EDMONDS� WA 98020 PORT LUDLOW, WA 98365 (425) 778-5400 (206) 380-5709 LICENSE #: PAULJJE941RA EXP:12/02/2020 JOB DESCRIP'nON DEMO EXISTING SFR. VALUATION: $0 PERMIT TYPE: Residential PERMIT GROUP: 23 - Demolition GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: OCCUPANT GROUP: OCCUPANT LOAD: FENCE: 0 X 0 FT.) CODE: IOTHER: ------- OTHER DESC: ZONE: INUMBER OF STORIES: 0 VESTED DATE: INUMBER OF DWELLING UNITS: 0 110T #� EXISTING AREA BASEMEN 1: 0 1 ST FLOOR: 0 2ND FLOOR: 0 PRO PO S ED AREA FBASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 13RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 13 RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 1BEDROOM& 0 BATHROOMS: 0 1 BEDROOMS: 0 BATHROOMS: 0 FRONTSETBACK SIDESErBACK REARSETBACK REQUIRED: PROPOSED: MRE UIRED: PROPOSED: JUQUIRED: PROPOSED: HEIGHT ALLOWED:O PROPOSED:0 IREQUIRED: PROPOSED: SETBACK NOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HP/HER DEPUTY AND ALL FEES ARE PAID. Signature Print Narne Date Releaded'By— bale 0- VO A.) 6 41 1-- all' - ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL ORA CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109/ IBCI 10/ IRCI 10. FIRE APPLICANT ASSESSOR Crry STATUS: ISSUED BLD20190189 • Final approval on a projector final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including fin a] project approval and final occupancy inspections. • Any request foralternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances orpolicies must be specificatly requested in writing and be cafled out and identified. Processing fees for such request shaU be estabhshed by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating fromtemporary construction sites as a result of construction activity are exempt fromthe noise lirnits of ECCChapter5.30 only during the hours of 7:00amto 6:00pmon weekdays and 10:00amand 6:00pmon Saturdays, excluding Sundays and Federal Holidays. At aU other times the noise originatin g from constructions ites /activities must coilp ly with the noise linits of Cbapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, aris ing directly or indirectly from the issuance for this permit. Issuance of this permit shaU not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's abi1ity to enforce any ordinance provision. INSPECTIONS THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) BUILDING i ENGINEERING (425) 771-0220 EXT. 1326 1. Go to: www.edmondswa.gov Building Department Inspections 2. Then: Services are now scheduled online. If you FIRE (425) 775-7720 3. Then: Permits/Development have difficulties, please call the 14. Then: Online Permit Info Building Department front desk for PUBLIC WORKS (425) 771-0235 5: If you don't have one already, create a assistance during office hours. login (upper right hand comer) :(425) 771-0220 RECYCLING (425) 275-4801 6: Schedule your inspection When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. • E-Engineering Final • E-Pre-Deniolition Sewer Cap • E-Pre-Demo Water Sery Discnct/AVB • &Pre -Demo Erosion Control • B-Bui1ding Final �11c. I S 9V BUILDING PERMIT APPLICATION Development Services Building Division 121 5th Ave N / Edmonds, WA 98020 425.771.0220 For handouts, submittal requirements, permit status and inspection scheduling information go to: httr)://www.edmondswa.gov JOB SITE INFORMATION/LOCATION: (Where the work is taking place) Job Site Address: 650 Bell Street Parcel: 00434209801700 Lot /Unit/Suite #: Subdivision: PROPERTY OWNER: Name. Vons Bell Street LLC Mailing Address: 440 12th Place North City/State/Zip: Edmonds, WA 98020 Phone #: (425) 280-5625 Email. Charles—vonacomcast. net OWNER INSTALLATION: *If yes, read and sign* Will work be performed by the property owner? 0 Yes I No I own, reside in, or will reside in the completed structure. This i nstallation is being made on property that I own which is not intended for sale, lease, rent, or exchange according to RCW 18.27.090. Owner Signature: APPLICANT / CONTACT INFORMATION: Name of Applicant: AD Shapiro Architects PS Mailing Address: 1207 N. 200th Street, Suite 105 City/State/Zip: Shoreline, WA 98133 Phone #: (425) 778-5400 E-mail: tonys@adshapiro.com GENERAL CONTRACTOR: (if different from applicant) General Contractor: Hardy Development Mailing Address: 4200 196th Street SW City/State/Zip: Lynnwood, WA Phone #: (425) 774-2200 E-mail: Robert@HardyDevco.com WA STATE CONTRACTOR L & I # (CCB) & EXPIRATION DATE: CITY OF EDMONDS BUSINESS LICENSE #: Office Use Only TYPE OF PERMIT (Provide 0 Accessory Structure/ Detached Garage Details on Page 2) 0 Addition 6 Demolition 0 Mechanical • New Single Family/ Duplex 0 Plumbing • Fire Sprinkler 0 Remodel El New Commercial/ Mixed Use 0 Re -Roof 0 Signs 0 Tank El Tenant Improvement 0 Other Remodel Permit fees are based on: The value of the work performed. Indicate the value (rounded to the nearest dollar) of all equipment, materiials, labor, overhead, and the profit for the work indicated on this application. Valuation: PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION Basement sq ft: Finished 0 Unfinished 11 Ist Floor, sq ft: 2nd Floor, scift: Garage/Carport:, sq ft: Deck/Covered Porch/Patio: Other sq ft: PROJECT DESCRIPTION Demolish existing house, and disconnect and cap existing utilities. I certify that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: Anthony D. Shapiro Signature: Date 02/21/19 GENERAL COMMERCIAL DATA Occupancy Group(s): Occupant Load(s): Type(s) of Construction: Fire Sprinklers: Yes El No 0 WA STATE ENERGY CODE: If your project affects the building envelope, mechanical systems, and/or lighting, you must complete the appropriate WSEC forms. DEFERRED SUBMITTALS: All commercial building permits that will require associated plumbing, mechanical, fire sprinkler, and/or fire alarm permits are applied for separately. TI / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet MECHANICAL EQUIPMENT COUNTS (New and Relocated) BTUs Gas Elec Other Qty A/C Unit /Compressor Air Handier /VAV Boiler Dryer Duct Exhaust Fans Fireplace Furnace Heat Pump Unit Hydronic Heating Roof Top Unit (Provide eleva- tions if a Commercial Bldg) Other: PLUMBING FIXTURE COUNTS (New, Relocated or re -piped) Qty Qty Clothes Washer Tub/ Showers Dishwasher Backflow Device (RPBA, DCDA, AVB) Drinking Fountain Pressure Reduction/ Regulator Valve Floor Drain/Sink Refrigerator Water Supply Hose Bibs Water Heater - Tankless? Y or N Hydronic Heat Water Service Line Sinks Other: Toilets Other: GAS/FUEL CONNECTION COUNTS (New, Relocated or re -piped) BTUs Qty BTUs Qty A/C Unit Outdoor BBQ / Fire pit Boiler Stove/Range/Oven Dryer Water Heater Fireplace/ Insert Other: Furnace Other: MEDICAL GAS, AIR VACUUM COUNTS (New, Relocated or re -piped) Qty Qty Carbon Dioxide Nitrous Oxide Helium Oxygen Medical Air Other: Medical - Surgical Vacuum Other: DEMOLITION Type of structure to be demolished: Single family house 1,053 bsmt Square footage of structure to be demolished: 1,053 main floor level AHERA Survey done? Y'@ PSCAA Case #: Critical Areas Determination: Study Required El Conditional Waiver 0 Waiver El Fill in Place 0 Fill Material: Removal D Size of Tank (Gallons) Critical Areas Determination: StudyRequiredE] Conditional Waiver 0 WaiverD GRADE/FILL/EXCAVATE Grading: Cut cubic yards Fill cubic yards Cut / Fill in Critical Area: Yes EJ No El GENERAL PROVISIONS APPLICATIONS: Applications are valid for a maximum of 1 year. ESLHA Applications, 2 years. LICENSING: All contractors and subcontractors are required to be licensed with Washington State Department of Labor & Industries and have a current City of Edmonds Business License. 0,� E 04f 0 Al CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 PHONE: (425) 771-0220 - FAX: (425) 771-0221 BUILDING APPLICATION ACCEPTANCE Friday, February 22, 2019 This Application has been accepted by the City of Edmonds for review. More information and changes may be required during this process. The review target date is: Your City Contact is: CHRISTINA WAYLAND Application Number: BLD20190189 Project Address: 650 BELL ST, EDMONDS PROPERTY OWNER APPLICANT I VONS BELL ST AD SHAPIRO ARCHITECTS PS C/O GOEDERT CHARLES VON 1207 N. 200 ST 440 12TH PL N SHORELINE, WA 98133 EDMONDS, WA 98020 (425) 778-5400 Work Description: DEMO EXISTING SFR. Outstanding Items at Time of Submittal: It is anticipated that the following departments will be reviewing your application: IJ Building Planning Engineering Fire -J Please waft to re -submit corrections until after you have received comments from all reviewing departments. I H ERERV AC KNO NN'LEDG E TH AT I HAVE READ TH IS APP LIC ATIO N TH AT TH E IN FO RMATIO N G IVEN IS C 0 RREC T AND TH AT I A M TH E PRO PERTY 0 W NER, 0 R TH E D ULY A UT11 0 RIZED AG ENT 0 F TH E PRO PERTY 0 %A- NER TO S I'B MIT A BUILDING PERMIT APPLIC ATIO N TO TH E C ITY. SIGNA-W-RE (OWNER OR AGENT) PRINT NAME DA'IESIGNED To view up to date information about your application please visit the City ofEdmonds Development Services website at hilp.11www.ednwndswa.gov. 6650 Be�_� St-reet -Town home,9 Demolition Permit Documents Demolition Notes: 1. All debris shall be properly stored on site or removed from the construction site daily. 2. All demolition work shall be performed In accordance with City regulations. 3. The contractor shall remove all pipes and sleeves below ard above grade. 4 - Contractor shall remove all dernolifion not implied or specified on drawings or specifications and to include such costs in bid unless otherwise advisied. 5. The contractor shall coordinate removal and capping of all existing links to off_site data ' power, gas, sanitarylstorm sewer and water with each utility and 'awider. 6. Refer to and comply with all other plans including, but not limited to Civil Engineeflng, City erosion control requirements, including forthe excavation and removal of existing foundation and the stabilization of the site after demolition is complete. 7 Maintain all public ways adjacent to the site in a clean and orderly la shlon 8. Provide all labor, material, equipment and services and perform all operations required for complete demolition and related work as described and specified herein, and as may be reasonably implied as necessary to complete the work in all respects. 9. Work shall conform to the latest edition of all applicable reference specifications and to governing building codes and requirements of authorities having jurisdiction. 10. Jobsite inspection must be conducted to examine existing conditions, to determine nature and scope of work or any difficulties that might arise at fine of work ' Exercise extreme care during demolition so as not to damage construction and other structures that am intended to remain. Anything damaged at time of work is to be repairer and/or replaced to match existing construction at contractors'expense. ,,. Contractor to provide dust protection and clean-up of public ways as required by ty and State regulations. Ci ' 12. When d-motition takes place, should any work affect the integrity of adjacent and/or off -site structures, work must stop immediately; notify the owner and architect immediately. Citv Demolition Notes: 1. Contact the City Water Department regarding water meter protection or removal 425-771-0220 ext. 1647. 2. The sewer line cap (at the property line) is required to be inspected by the City. Call 425-771-0220 ext. 1326. Sewer laterals may only be capped with a correct size screw plug (a concrete patch is not permitted). 3. Temporary erosion control is required prior to, during and post demolition work. See: Erosion Standards 4. All materials must be dumped at approved dump area. 5. Th: :treat is to be clean of debris, vegetation. and garbage at all times 6 Th ide sewer must be capped at the property line (inspection approval required). 7. The lot must be graded back to the original grade contours. 8. Underground tanks are to be pumped, cleaned, capped or removed (separate permit required) . 9� Salado Wake are to be pumped, collapsed and removed and/or filled with earth, sand , concrete, CDF or hard slurry. 10. The City shall require repair, or restitution of, any public property damaged duringthe work. 11. The City encourages recycling of demolition and construction materials. Puaet Sound Clean Air Aaenc Before you can legally start any demolition (or most renovation) proj-ts, you MUST meet these asbestos requirements: Conduct an Asbestos Survey This survey must be conducted by an AHERA*-cerfified building inspector. You can search for them on the web or in phone books under "Asbestos Consulting and Testing* . The results of the survey must either be posted at the work site or communicated in writing to anyone who may come into contact with the material. File a Notification You must file a completed notification and pay a fee to the Puget Sound Clean Air Agency at —pscleanairomilasibestos, before you begin demolition. Properly Remove Asbestw All asbestos -containing materials must be removed from the structure by an asbestos contractor prior to demolition. Contact the Puget Sound Clean Air Agency at —psoleanair.org/astaestos or call 206-6894058. Sheet Index A003 Demolition Cover Sheet, Demolition Plan Survey ProjectSu'vey Coll Civil Cover Sheet and TESC Plan Not% This demolition submittal is to augment the overall applicafion for building permit made for Z sitelproject, to the City of Edmonds in December 201 8 _ 650 Bell Street, Edmonds, WA 98020 Disconnect existing overhead power and data lines W — W 4--1 A _X_X Ry r ROCKE Cap existing water line at meter Demolish existing wood frame residence and foundation, prior to excavation of � existing foundation, verify there will be In, impacts on adjacent properties V Note: refer to civil drawing C01 for flag note definitions, TESP Remove existing side sewer line V) Cap a isfing side sewer, and prep for future I ink to new construction ASPI 1AL�T DRIVEVW Y Sit - X, Bell Street W W—W 4 1 X X _X Iq �A M X i X STEPS 4 W 09J 911 0 X 4"1" 1Z_ 9 �? 'i I K 7, Tt-7-bcmI5�u . gc-�, — B 7iji7- —sa . — S 5t*LL �eTt.�,Yr c6 R. C 2 C11 E aij� go, C, —0 0 C: co 0 E IM, W U) aa)) (D U) 0 U.) 0 2 z,. egiste d VtW..wig I I t t WD.SMPIRD .gt Ph inn g n L 7`1 0 _0 in W SHEET TIT E CoverS h-t, Dem.litio, Site Pl., RECEIVED FEB 2 2 2019 BUILDING SCALE: DRAWN BY: 110 = T-G" Author DATE: CHECKED BY: -02J21/19 Checker ENGINEERING DIVISION PROJI. No: 12583-00 olit mn SHEET No: M-OPite Plan MY COPY Issue for Permit A003 8 zo ol� E5 0 z a 0 v v v v v I v GENERAL NOTES: NECESSARILY COMPLETE. IT IS THE SOLE 15. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR 25. THIS PROJECT IS NOT A BALANCED EARTHWORK RESPONSIBILITY OF THE CONTRACTOR TO DIMENSIONS AND LOCATIONS OF BUILDINGS, PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND INDEPENDENTLY VERIFY THE ACCURACY OF ALL LANDSCAPED AREAS AND OTHER PROPOSED OR ROCK MATERIALS ARE REQUIRED. N < 1 . ALL MATERIALS AND WORK SHOWN ON THESE PLANS UTILITY LOCATIONS SHOWN AND TO FURTHER EXISTING SITE FEATURES. 26. SLOPE OF FINISHED GRADE SHALL BE CONSTANT SHALL CONFORM TO THE CITY OF EDMONDS DISCOVER AND PROTECT ANY OTHER UTILITIES NOT 16. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER BETWEEN FINISHED CONTOURS OR SPOT STANDARD PLANS AND DETAILS, THE FOLLOWING SHOWN HEREON WHICH MAY BE AFFECTED BY THE FOUNDATION DRAINS. FOUNDATION DRAINS SHALL ELEVATIONS SHOWN. SPECIFICATIONS AND CODES, AND ALL OTHER IMPLEMENTATION OF THIS PLAN. CONTRACTOR BE INDEPENDENT OF OTHER SITE DRAIN LINES AND 27. FINISHED GRADE SHALL SLOPE AWAY FROM 10 5 0 10 20 APPLICABLE LOCAL MUNICIPAL, STATE, AND SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE AND SHALL BE TIGHTLINED TO THE STORM DRAIN SYSTEM BUILDING WALLS AT MINIMUM 5% SLOPE FOR A FEDERAL CODES, RULES AND REGULATIONS: CONDITION OF EXISTING UTILITY LINES AT WHERE INDICATED ON THE PLANS. MINIMUM DISTANCE OF 10 FEET. SCALE IN FEET CURRENT INTERNATIONAL BUILDING CODE(IBC) CONNECTION OR CROSSING POINTS BEFORE 17. ALL REQUIRED STORMWATER FACILITIES MUST BE 28. CONTRACTOR SHALL BE RESPONSIBLE FOR AND 2016 WSDOT/APWA STANDARD SPECIFICATIONS TRENCHING FOR NEW UTILITIES. ENGINEER CONSTRUCTED AND IN OPERATION PRIOR TO SHALL INSTALL AND MAINTAIN SHORING AND KEY NOTES FOR ROAD, BRIDGE AND MUNICIPAL ASSUMES NO RESPONSIBILITY FOR THE INSTALLATION OF ANY PAVEMENT UNLESS BRACING AS NECESSARY TO PROTECT WORKERS, CONSTRUCTION COMPLETENESS OR ACCURACY OF THE EXISTING OTHERWISE APPROVED BY THE ENGINEER. EXISTING BUILDINGS, STREETS, WALKWAYS, KEY DESCRIPTION DETAIL/ SHEET - WASHINGTON STATE DEPARTMENT OF ECOLOG UTILITIES AND SITE FEATURES PRESENTED ON 18. ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, UTILITIES AND OTHER EXISTING TEMPORARY STORM DRAIN STORMWATER MANAGEMENT MANUAL FOR THE THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL AND PROPOSED IMPROVEMENTS AND :NSTALL NLET PROTECTION C/Cos PUGET SOUND BASIN (CURRENT EDITION). IMMEDIATELY OF CONFLICTS THAT ARISE. BE CONNECTED TO THE STORM DRAINAGE SYSTEM, EXCAVATIONS AGAINST LOSS OF GROUND OR 2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON 8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UNLESS NOTED OTHERWISE. CAVING EMBANKMENTS. CONTRACTOR SHALL :NSTALL TEMPORARY STORM DRAIN THESE DRAWINGS REFER TO CITY OF EDMONDS UTILITIES DURING CONSTRUCTION AND SHALL 19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ALSO BE RESPONSIBLE FOR REMOVAL OF SHORING NLET PROTECTION TO STORM DRAIN C/C05 STANDARD DETAILS, UNLESS NOTED OTHERWISE. CONTACT THE UNDERGROUND UTILITIES. LOCATION ROCKERIES, ETC. SHALL CONNECT TO THE AND BRACING, AS REQUIRED. INLETS WITHIN 50'OF THE SITE 3. A COPY OF THESE APPROVED PLANS MUST BE ON SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR DRAINAGE SYSTEM DOWNSTREAM OF THE SITE 29. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CONTRACTOR TO SWEEP THE JOBSITE WHENEVER CONSTRUCTION IS IN TO CONSTRUCTION. STORMWATER DETENTION SYSTEM. CITY AND FOLLOW CITY PROCEDURES FOR ALL STREETSALLEY DAILY OR AT MORE PROGRESS. 9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND 20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL WATER SERVICE INTERRUPTIONS, HYDRANT FREQUENT INTERVALS AS NEEDED 4. DEVIATIONS FROM THESE PLANS MUST BE DIMENSIONS AT THE PROJECT SITE BEFORE PERMITS REQUIRED FOR SHUTOFFS, STREET CLOSURES OR OTHER ACCESS (D INSTALL APPROXIMATELY 275 LF A & D/CO5 APPROVED BY THE ENGINEER OF RECORD AND THE STARTING WORK AND SHALL NOTIFY OWNER'S INSTALLATION OF ALL SITE IMPROVEMENTS RESTRICTIONS. CONTRACTOR SHALL NOT PERIMETER PROTECTION* LOCAL GOVERNING AUTHORITY. REPRESENTATIVE OF ANY DISCREPANCIES. INDICATED ON THESE DRAWINGS. RELOCATE OR ELIMINATE ANY HYDRANTS ALL EXISTING IMPERVIOUS SURFACES 5. CONTRACTOR SHALL RECORD ALL APPROVED 10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE 21. A SEPARATE IRRIGATION PERMIT MUST BE OBTAINED WITHOUT FIRST OBTAINING WRITTEN APPROVAL (D AND VEGETATION ONSITE TO BE DEVIATIONS FROM THESE PLANS ON A SET OF AND MAY CHANGE DUE TO FIELD CONDITIONS. FROM THE CITY PUBLIC WORKS DEPARTMENT. PRIOR FROM THE FIRE MARSHAL. REMOVED "AS -BUILT" DRAWINGS AND SHALL SUMMARIZE ALL 11. CONTRACTOR SHALL OBTAIN A COPY OF THE TO FINAL CONSTRUCTION ACCEPTANCE, 30. COORDINATE AND ARRANGE FOR ALL UTILITY INSTALL TEMPORARY STABILIZED AS -BUILT CONDITIONS ON ONE SET OF GEOTECHNICAL REPORT (WHERE APPLICABLE) AND PROVIDE TO THE CITY WATER QUALITY CONNECTIONS, UTILITY RELOCATIONS AND/OR CONSTRUCTION ENTRANCE F/CO5 REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE TECHNICIAN, A COPY OF THE BACKFLOW TEST SERVICE INTERRUPTIONS WITH THE AFFECTED OWNER PRIOR PROJECT COMPLETION AND CONTENTS THEREOF. ALL SITE WORK SHALL BE REPORT. TEST REPORTS CAN BE FAXED TO OWNERS AND APPROPRIATE UTILITY COMPANIES. PRELIMINARY STOCKPILE LOCATION. 3 ACCEPTANCE. A SET OF AS -BUILT DRAWINGS SHALL PERFORMED IN STRICT COMPLIANCE WITH THE 425-744-6057 OR EMAILED TO CONNECTIONS TO EXISTING UTILITIES SHALL BE CONTRACTOR TO DETERMINE FINAL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR TO RECOMMENDATIONS OF THIS REPORT. JEFF.KOBLYK@EDMONDSWA.GOV. BACKIFLOW MADE ONLY WITH ADVANCE WRITTEN APPROVAL OF STOCKPILE LOCATION FINAL APPROVAL OF THE BUILDING 12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL TESTING SHALL BE COMPLETED BY THE OWNER THE AUTHORITIES GOVERNING SAID UTILITIES. PROTECT DRYWELL SUBGRADE FROM OCCUPANCY/FINAL PROJECT APPROVAL. CONFORM TO THE RECOMMENDATIONS OF THE ANNUALLY THEREAFTER. 31. ALL UTILITIES SHALL BE PLACED UNDERGROUND. COMPACTION DURING 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR PROJECT GEOTECHNICAL REPORT. 22. AS A MINIMUM REQUIREMENT, ALL DISTURBED 32. EXISTING UTILITY LINES IN SERVICE WHICH ARE CONSTRUCTION FROM HEAVY BENCHMARK INFORMATION. 13. SUBGRADE SOILS IN ALL AREAS WHERE RAIN AREAS ON AND OFF SITE SHALL BE RETURNED TO DAMAGED DUE TO CONSTRUCTION WORK SHALL BE EQUIPMENT AND SOIL STOCKPILING 7. THE LOCATIONS OF EXISTING UTILITIES AND SITE GARDENS, INFILTRATION OR PERVIOUS PAVEMENT IS THE EQUIVALENT OF THEIR PRECONSTRUCTION REPAIRED AT CONTRACTOR'S EXPENSE AND INSTALL PERIMETER PROTECTION SUCH AS SILT FENCING, FEATURES SHOWN HEREON HAVE BEEN FURNISHED TO BE PLACED SHALL BE DELINEATED AND CONDITION IN ACCORDANCE WITH APPROPRIATE INSPECTED AND ACCEPTED BY CITY OF EDMONDS COMPOST SOCKS, OR STRAW WATTLES IN ACCORDANCE BY OTHERS BY FIELD SURVEY OR OBTAINED FROM PROTECTED AT ALL TIMES FROM COMPACTIVE REQUIREMENTS AND STANDARDS. AND OWNER'S REPRESENTATIVE PRIOR TO WITH VOL. 11 OF THE DOE 2012 (2014 AMENDED) AVAILABLE RECORDS AND SHOULD THEREFORE BE ACTIVITIES (I.E. HEAVY EQUIPMENT, STOCKPILING). 23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST BACKFILLING. STORMWATER MANAGEMENT MANUAL FOR WESTERN CONSIDERED APPROXIMATE ONLY AND NOT 14. MANHOLES, CATCH BASINS, UTILITIES AND AMENDED AND SEEDED OR STABILIZED BY OTHER 33. NEW UTILITY LOCATIONS ARE GENERALLY SHOWN WASHINGTON PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY ACCEPTABLE METHODS FOR THE PREVENTION OF BY DIMENSION, WHERE NO DIMENSIONS ARE DENSE NATIVE SOIL OR COMPACTED STRUCTURAL ON -SITE EROSION AFTER THE COMPLETION OF INDICATED, LOCATIONS MAY BE SCALED FROM FILL. IF SOIL IS DISTURBED, SOFT, LOOSE, WET OR IF CONSTRUCTION. SEE EROSION DRAWINGS. FIELD ADJUSTMENTS SHALL BE ORGANIC MATERIAL IS PRESENT AT SUBGRADE CONTROL PLANS FOR SPECIFIC GRADING AND APPROVED BY OWNER'S REPRESENTATIVE AND CITY. ELEVATION, REMOVE AND REPLACE WITH EROSION CONTROL REQUIREMENTS. 34. FIELD STAKE ALL UTILITY STUBS AT THE PROPERTY COMPACTED STRUCTURAL FILL PER GEOTECHNICAL 24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS LINE. REPORT. CLEAN AT ALL TIMES BY SWEEPING. WASHING OF 35. TRENCH BACKFILL OF UTILITIES LOCATED WITHIN ��F��E,��.WILL NOT BE ALLOWED WITHOUT CONSTRUCTION SEQUENCE NOTES 40 1. SCHEDULE A PRE-CONSTRUCITON MEETING WITH CITY ENGINEERING DIVISION AT 425-771-0220, EXT. 1326. TWO DAY (48 1 HR) NOTICE IS REQUIRED. 2. REVIEW ESC NOTES. 3. CALL FOR UTILITY LOCATES. 4. INSTALL ESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING DISTURBANCE OF ANY AREAS OF VEGETATION OUTSIDE THE CONSTRUCTION ZONE. 5. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF EDMONDS CITY ENGINEERING INSPECTOR. (ALL TEMPORARY �2 SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE _X010-00N a. o 8 _4� X, PRACTICES X-X X" CLEARING. EROSION AND SEDIMENTATION CONTROL X=='� x x - x X=.!! x NJ _-_-7_--`x7x-1 x-x-x-lx\- AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETATION IS ESTABLISHED.) 6. DEMOLISH EXISTING STRUCTURES. 7. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES. 8. CLEAR, GRUB & ROUGH GRADE REMAINDER OF SITE. REVEGETATE DISTURBED AREAS NOT SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. (OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES BELOW) 9. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS, INCLUDING FRONTAGEIMPROVEMENTS. 10. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGETATION OF ENTIRE SITE. 11. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY EROSION CONTROL MEASURES CAN BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR. . . ..... ... 3 8 x .. . ................ 6 ........................ \... T . . ....... . . x SSG . .......... _=SS , - ss -SSG x x _x x x:z=kw;;�i-L:-__x --- L�;X_x x x .96*601 3.%ftDo 9 ej % 2 19- > To A - A - A - A THE CITY RIGHT-OF-WAY SHALL BE COMPACTED TO 95%. COMPACTION TEST REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO PAVING. 36. WHERE NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS, PLACE POLYETHYLENE PLASTIC FOAM AS A CUSHION BETWEEN THE UTILITIES. 37. SEE MECHANICAL DRAWINGS (WHERE APPLICABLE) FOR CONTINUATION OF SITE UTILITIES WITHIN THE BUILDING. 38. SEE ELECTRICAL DRAWINGS (WHERE APPLICABLE) FOR EXTERIOR ELECTRICAL WORK. 39. SEE LANDSCAPE DRAWINGS (WHERE APPLICABLE) FOR SITE IRRIGATION SYSTEM. 40. PIPE MATERIAL AND SIGNAGE SUBMITTALS SHALL BE PROVIDED TO CITY ENGINEERING DIVISION FOR APPROVAL PRIOR TO INSTALLATION. I �fl�KIM. MT� TEMPORARY CONSTRUCTION ENTRANCE _x_ PERIMETER PROTECTION STOCKPILE LOCATION CIVIL PLAN SHEET INDEX SHEET DESCRIPTION: Col TESC PLAN CO2 GRADING PLAN CO3 FRONTAGEIMPROVEMENTS PLAN C04 DRAINAGE & UTILITY PLAN COS DETAII S C06 DETAILS ABBREVIATIONS: BLDG = BUILDING BM = BENCHMARK BOTS = BOTTOM OF STEP(S) CB = CATCH BASIN CIL = CENTERLINE CW = CONCRETE WALK DRN = FOOTING DRAIN EG = EXISTING GRADE EL = ELEVAT:ON ELEV = ELEVAT ON ESMT =EASEMENT EX = EXISTING FF = FINISHED FLOOR FG = FINISHED GRADE FH = LOCATION OF NEAREST FIRE HYDRANT FL = FLOW LINE G = GAS HMA = HOT MIX ASPHALT ID = INNER DIAMETER IE = INVERT ELEVATION LF = LINEAL FEET Ls = LAND SURVEYOR OHP = OVERHEAD POWER PIL = PROPERTY LINE PVI = POINT OF VERTICAL INTERSECTION ROW = RIGHT OF WAY SID = STORM DRAIN SDCO = STORM DRAIN CLEANOUT SDFM = STORM DRAIN FORCE MAIN SDMH = STORM DRAIN MANHOLE Ss = SANITARY SEWER SSMH = SANITARY SEWER MANHOLE SSS = SANITARY SIDE SEWER SSSCO =SANITARY SIDE SEWER CLEANOUT TOC = TOP OF CURB TOPS = TOP OF STEP(S) TYP = TYPICAL W = WATER RECEIVED WDF � WOOD FENCE FEB 2 2 2019 BUILDING z a �z z 0 �oozww �00909 z,o,=iz mw 0. 121 z 0 ly It a < &j D c) 1_� (9 =; 92 q z m.. WIZO 0 LU _l ti. -m LLI E Z w X. . LLT ci 1. "20 (6 �6,q I-_ of c:) c:) LU Z CN c\I 0 C) CD LU Lu OD 00 0 C) M M (.9 5 < U) < Z z , �: - �: _<j 0 m u� LLI cd a_ > P b m 0 0 U) N z - z U) LU - o (10 o LU _j 0 j)f �t < -t _r w w 0 019 PROJ. MANAGER: Bi DESIGNED -BY: B1, JL DRAWN BY: RB, JA ZHECKED BY: 77 SCALE: AS SHUNN 12/1412018 CITY OF EDMONDS DATE: BY: CITY ENGINEERING DMSION (;o 1