APPROVED BLD2023-0157+Calculations+2.8.2023_11.16.55_AM+33584843/4" APA PLYWOOD FLOOR
IMPORTANT NOTES FOR CONTRACTOR:
SHEATHING WITH 10d NAILS AT
1. PROVIDE TEMPORARY SHORING AS
6" EDGE & BLOCKING NAILING
NECCESSARY PRIOR TO DEMOLITION WORKS
AND 10d AT 12" FIELD NAILING
2. NOTIFY ENGINEER OF ANY DISCREPANCY
1 IN COMPARISON WITH STRUCTURAL
REPLACE EXISTING DAMAGED POST
S-1 DOCUMENTS AND FIELD CONDITIONS
WITH NEW 4X4 POST, REUSE EXISTING
HARDWARE OR REPLACE WITH NEW
SIMILAR ALTERNATIVE
LU
LLJw
PROVIDE (2)1.75X5.5 LVL 1.8E (OR BETTER)
I _UNDER
STUD WALLS PARALEL TO JOISTS
N z
AND FOR STAIR SUPPORT (DB-1)
U
k
Q
k
Y
REPLACE EXISTING DAMAGED 2X6 JOISTS
LO U
(SISTERED TO EXISTING 2X8 JOISTS WITH NEW
m
2X6 JOISTS (BOTH SIDES) @ 16" O.C. (DJ-1)
1
k
i k k 11 1 k
i k k 11 1 k
k II I k
EXISTING 2X8 JC ISTS
@ 16" O.C. TO R MAIN
II II II EXISTING BEAM
TO REMAIN
UPPER FLOOR
U 1/4" = 1'-0"
FOR DIMENSIONAL LUMBER:
PROVIDE (2)WSV3S SCREWS @ 16" O.C. (BOTH SIDES) Lu
0
FOR LVL MEMBERS: o w — EXISTING JOIST
LU PROVIDE (2)SDS25412 SCREWS @ 16" O.C. (BOTH SIDES) z Q
3 1/2" MIN END
H2.5 TIE AT EACH JOIST o DISTANCE
f
- - - - - - - - - - - - - - Z
16" +/_ w
w
�U)
2'- 6" CANTILEVER 5' - 0" BACKSPAN w
m0
Z
n Section 1.1
3/4" = 1'-0"
------------------------------------------ - - - - -.
= The following documentation shall be available on '
site for the building inspector:
x❑ COE APPROVED ARCHITECTURAL PLAN SET '
: ❑ COE APPROVED STRUCTURAL PLAN SET
❑ COE REVIEWED CALCULATION PACKET
ENERGY CREDIT WORKSHEET
❑ SITE PLAN ;
❑ CIVIL PLAN i
■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ;
CITY OF EDMONDS
BUILDING DIVISION
APPROVED PLAN
02/10/2023
Eri n C%t�
WALL SHEATHING NOTE:
WHERE SHEATHING IS APPLIED
TO BOTH SIDES OF WALL,
OFFSET PANEL EDGES TO FALL
ON DIFFERENT STUDS.
16d @ 6" O.C.
EXISTING GUARDRAIL
TO REMAIN
/ V`ti
WATER -PROOFING AND
WALL CAP BY OTHERS
— REPLACE EXISTING DAMAGED STUD
WALL W/ NEW 2X6 STUD WALL @ 16" O.C.
-7—PROVIDE 1/2" PLY OR OSB WALL
SHEATHING (BOTH SIDES) W/ 10d @
6" AT EDGES AND 10d @ 12" FIELD
NAILING (PANELS SHALL BE
STAGGERED WITH OPPOSITE SIDE)
2X6 RIM 0/1
BOARD
2'-6"
CANTILEVER
- -III- -.III
Section 1
BACKSPAN
PROVIDE 2X SHIM
UNDER CANT. JOISTS
EXISTING STUD
WALL TO REMAIN
EXISTING ROOF — _[ — —
FRAMING TO REMAIN
EXISTING UPPER DECK
FRAMING TO REMAIN
EXISTING STUD
WALL TO REMAIN
REPLACE EXISTING DECK SHEATHING
IF REQUIRED, SEE PLAN FOR FLOOR
SHEATHING SIZE AND NAILING
SISTER NEW JOIST PER PLAN
EXISTING FLOOR
JOISTS TO REMAIN X
1.1\
S-1 EXISTING BEAM
TO REMAIN
EXISTING SLAB ON
GRADE TO REMAIN
EXISTING FOUNDATION WALL
WITH FOOTING TO REMAINI
III III III III III III Ill Ill Ill III �
IMPORTANT NOTES ON DRAWING REVIEW. FIELD VERIFICATION. TEMPORARY SHORING
AND WATERPROOFING:
1. CONTRACTOR MUST REVIEW STRUCTURAL DRAWINGS PRIOR TO CONSTRUCTION &
NOTIFY DESIGN TEAM/OWNER OF ANY DISCREPANCY IN COMPARISON WITH
ARCHITECTURAL DOCUMENTS OR FIELD CONDITIONS.
2. IN REMODEL/RETROFIT PROJECTS, CONTRACTOR MUST FIELD VERIFY & NOTIFY
DESIGN TEAM/OWNER OF EXISTING MECHANICAL, PLUMBING, AND ELECTRICAL LINES
THAT MAY INTERFERE WITH STRUCTURAL WORK PRIOR TO CONSTRUCTION.
STRUCTURAL DRAWINGS MAY NOT REFLECT ALL EXISTING FRAMING CONDITIONS DUE
TO LIMITED AVAILABLE INFORMATION.
3. CONTRACTOR IS SOLELY RESPONSIBLE IN PROVIDING PROPER TEMPORARY SHORING
PRIOR TO REMOVING ANY STRUCTURAL ELEMENTS.
4. ENGINEER IS NOT RESPONSIBLE FOR WATERPROOFING SYSTEM OR DETAILS.
CONTRACTOR/OWNER SHALL CONSULT WITH QUALIFIED PROFESSIONALS AS REQUIRED
LEGEND AND NOTES
PREPARED FOR
CHERMAK
CONSTRUCTION INC.
www.b2engineers.com
10600 WOODINVILLE DR
BOTHELL, WA 98011
(425) 318-0031
info@b2engineers.com
Project Contact:
Principal: BB
Engineer: AL
�.■.�
�FL\
Bq
yPy OF WAS/y
o
Q-
�fj �QG 43789
X, URA L ENGNG�C��
SS/ONAL
E
DEVI-PAGE DECK
REPAIR
509 6TH AVE S,
EDMONDS, WA 98020
DRAWING SIZE 18112411
ISSUE DATE 02-07-23
ISSUED FOR PERMIT
PROJECT NO.22324
DESIGNER AL
REVISION SCHEDULE
NO. DATE DESCRIPTION
RECEIVED
Feb 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2023-0157
FRAMING PLAN
AND DETAILS
S-1
1 /4" = 1'-0"
Copyright b2 Structural Engineers 2008
1 of 4
m r •
info@?b2engineers.com
425-318-7047(0)
425-318-0031(C)
DEVI-PAGE DECK REPAIR
509 6TH AVE S, EDMONDS, WA 98020
STRUCTURAL CALCULATIONS
PROJECT NO: 22324 DATE:02/06/23
PREPARED BY: BASRI BASRI PE, SE
Desian Criteria
International Building Code (IBC) 2018
American Society of Civil Engineers (ASCE) 7-16
Project Description
Repair of existing deck include replacement of existing water damaged wood members with
new members of the same size.
Please see attached calculations for your reference.
Live Load and Other Structural Criteria
Roof Snow (psf)
25
Residential Live Load (psf)
40
Balcony, Deck and Platform Live Load (psf)
60
Office Live Load (psf)
50
Garage Live Load (psf)
40 with 3000# point load
Retail, Corridor, Walkway Live Load (psf)
100
Allowable Soil Bearing Pressure (psf)
1500 (assumed)
Soil Active Pressure (pcf)
35 (assumed)
�, Bq
of wAg�y7 s'p
43789
o�� CrURA L ENG�G�
SS�ONAL E
2 of 4
3/4" APA PLYWOOD FLOOR
SHEATHING WITH 10d NAILS AT
6" EDGE & BLOCKING NAILING
AND 10d AT 12" FIELD NAILING
REPLACE EXISTING WATER -DAMAGED
POST WITH NEW 4X4 POST, REUSE
EXISTING HARDWARE OR REPLACE
WITH NEW SIMILAR ALTERNATIVE ry
w
w
J_
N ~
Z
Q_
U
Q II
o CO
CO II
m I II I
II I
II I
II I II
II I II
1
S-1
EXISTING 2X8 JC ISTS
10, 16" O.C. TOR MAII
II II IIlim
ii 11 11 1
IILU1Id:4r_1ki111ikiIQIII = ;Ii]:Zdi]z1119:LT41ti1
1. PROVIDE TEMPORARY SHORING AS
NECCESSARY PRIOR TO DEMOLITION WORKS
2. NOTIFY ENGINEER OF ANY DISCREPANCY
IN COMPARISON WITH STRUCTURAL
DOCUMENTS AND FIELD CONDITIONS
PROVIDE (2)1.75X5.5 LVL 1.8E (OR BETTER)
UNDER STUD WALLS PARRALEL TO JOISTS
AND FOR STAIR SUPPORT (DB-1)
F _7____7F_
II II II
II I I
REPLACE EXISTING WATER -DAMAGED 2X6 JOISTS
(SISTERED TO EXISTING 2X8 JOISTS @ 16" O.C.)
WITH NEW (2)2X6 JOISTS @ 16" O.C.
II II II
II II II
II II II
II II II
II II II
EXISTING BEAM
TO REMAIN
Project: DEVI PAGE REMODEL
Location: DB-1
Multi -Span Floor Beam
[2015 International Building Code(2015 NDS)]
( 2 ) 1.75 IN x 5.5 IN x 7.5 FT (2.5 + 5)
1.8E-2600F - APA EWS LVL Stress Classes
Section Adequate By: 3.0%
Controlling Factor: Deflection
DEFLECTIONS
Left
Center
Live Load 0.03
IN 2L/2122
0.01 IN L/4671
Dead Load 0.15
in
-0.03 in
Total Load 0.18
IN 2L/330
-0.04 IN L/1475
Live Load Deflection Criteria: L/480
Total Load Deflection Criteria: L/320
REACTIONS A
B
Live Load 449
lb 200 lb
Dead Load 1956
lb -15 lb
Total Load 2405
lb 185 lb
Uplift (1.5 F.S) 0
lb -64 lb
Bearing Length 0.98
in 0.08 in
BEAM DATA
Left
Center
Span Length
2.5 ft
5 ft
Unbraced Length -Top
0 ft
0 ft
Unbraced Length -Bottom
0 ft
5 ft
Floor Duration Factor
1.00
Notch Depth
0.00
MATERIAL PROPERTIES
1.8E-2600F - APA EWS LVL Stress Classes
Base Values Adjusted
Bending Stress: Fb = 2600 psi Fb' = 2844 psi
Cd=1.00 C/=0.99 CF=1.10
Shear Stress: Fv = 285 psi Fv' = 285 psi
Cd=1.00
Modulus of Elasticity: E = 1800 ksi E' = 1800 ksi
Comp. -L to Grain: Fc -1= 700 psi Fc - -L = 700 psi
Controlling Moment: -1892 ft-lb
Over left support of span 2 (Center Span)
Created by combining all dead loads and live loads on span(s) 1, 2
Controlling Shear: -1241 lb
At a distance d from the right support of span 1 (Left Span)
Created by combining all dead loads and live loads on span(s) 1, 2
Comparisons with required sections: Rea'd Provided
Section Modulus: 7.98 in3 17.65 in3
Area (Shear): 6.53 in2 19.25 in2
Moment of Inertia (deflection): 47.12 in4 48.53 in4
Moment: -1892 ft-lb 4183 ft-lb
Shear: -1241 lb 3658lb
3 of 4 Page
Alex
StruCalc 9.0
StruCalc Version 10.2.1.0 2/6/2023 9:47:49 AM °f
2.5
FLOOR LOADING
Left
Center
Floor Live Load
FLL =
60
psf
60
psf
Floor Dead Load
FDL =
15
psf
15
psf
Floor Tributary Width Side One
TW1 =
1.3
ft
1.3
ft
Floor Tributary Width Side Two
TW2 =
0
ft
0
ft
Wall Load
WALL =
500
plf
100
plf
BEAM LOADING
Left
Center
Reduced Floor Live Load
60
psf
60
psf
Total Live Load
80
plf
80
plf
Total Dead Load
520
plf
120
plf
Beam Self Weight
6
plf
6
plf
Total Load
605
plf
205
plf
Project: DEVI PAGE REMODEL
Location: DJ-1
Floor Joist
[2015 International Building Code(2015 NDS)]
(2 ) 1.5 IN x 5.5 IN x 7.5 FT (2.5 + 5) @ 16 O.C.
Stud - Hem -Fir - Dry Use
Section Adequate By: 123.4%
Controlling Factor: Deflection
4 of 4 page
Alex
StruCalc 9.0
StruCalc Version 10.2.1.0 2/6/2023 9:47:50 AM °f
CAUTIONS
. Properly connect sheathing to double joists/rafters or fully laminate to transfer dia
DEFLECTIONS
Left
Center
Live Load
0.05 IN 2L/1210
0.02 IN L/2662
Dead Load
0.03 in
0.00 in
Total Load
0.07 IN 2L/804
0.02 IN L/3083
Live Load Deflection Criteria: L/480
Total Load Deflection Criteria: L/360
REACTIONS
A B
Live Load
450 lb 200 lb
Dead Load
173 lb 18 lb
Total Load
623 lb 218 lb
Uplift (1.5 F.S)
0 lb -38 lb
Bearing Length
0.51 in 0.18 in
SUPPORT LOADS A B
Live Load
338 plf 150
plf
Dead Load
130 plf 14
plf
Total Load
467 plf 164
plf
MATERIAL PROPERTIES
Stud - Hem -Fir
Base Values Adjusted
Bending Stress: Fb = 675 psi Fb' = 772 psi
Cd=1.00 CI=0.99 CF=1.00 Cr=1.15
Shear Stress: Fv = 150 psi Fv' = 150 psi
Cd=1.00
Modulus of Elasticity: E = 1200 ksi E' = 1200 ksi
Comp. -L to Grain: Fc -1= 405 psi Fc -1' = 405 psi
Controlling Moment: -413 ft-lb
Over left support of span 2 (Center Span)
Created by combining all dead loads and live loads on span(s) 1, 2
Controlling Shear: 288 lb
At a distance d from left support of span 2 (Center Span)
Created by combining all dead loads and live loads on span(s) 1, 2
Comparisons with required sections:
Rep d
Provided
Section Modulus:
6.41 in3
15.13 in3
Area (Shear):
2.88 in2
16.5 in2
Moment of Inertia (deflection):
18.62 in4
41.59 in4
Moment:
-413 ft-lb
973 ft-lb
Shear:
288lb
1650lb
forces.
LOADING DIAGRAM
1
�2.5ft 5ft
JOIST DATA Left Center
Span Length 2.5 ft 5 ft
Unbraced Length -Top 0 ft 0 ft
Unbraced Length -Bottom 0 ft 0 ft
Floor sheathing applied to top of joists -top of joists fully braced.
Floor Duration Factor 1.00
JOIST LOADING
Uniform Floor Loading
Left
Center
Live Load ILL =
60
psf
60
psf
Dead Load DL =
15
psf
15
psf
Total Load TL =
75
psf
75
psf
TL Adj. For Joist Spacing wT =
100
plf
100
plf
Wall Loading
Wall One
Live Load (1 to Joists): L1 =
0
plf
0
plf
Dead Load ( -L to Joists):D1 =
30
plf
0
plf
Load Location X1 =
0
ft
0
ft