Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2021-0926+Interior_Lighting_Summary+7.1.2021_11.11.55_AM+2279259
6/30/2021 hfps://waenergycodes.com/print_project_summary_form.php?k=aWQ9Mzk3NyZmdmk9MTgmY3RpPQ==&print=1 REVIEWED LIGHTING COMPLIANCE SUMMARY IV OF EDMOND," 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2021 NEEA, All rights reserved Project Title PSM OFFICE BUILDING TENANT IMPROVEMENTS - 2018 WSEC For Building Department Use: Date: Ju101, 2021 Project Address 7614 195TH STREET SW RECEIVED Project & Applicant EDMONDS, WA 98026 Applicant Name Office HBHU Information Jul 022021CITY gLD2021-0926 P Applicant Phone 253-383-3257 DEVELOPMENT SOERDV CES Applicant Email wamec@hultzbhu.com DEPARTMENT For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Professional Services Building Cond. Floor Area 6,833 General Project Types Alteration New Building or Addition Lighting Scope g g P Alteration Lighting Scope Interior Lighting Project Cond. Floor Area 3,237 Floors Above Grade 2 Compliance Method Compliance Method 1 -General Lighting Project Description TENANT IMPROVEMENTS TO EXISTING OFFICE BUILDING. Lighting Compliance Scope Project a J Type Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope p p Compliance Method p LPA Calculation Adjustment Compliance Verification p and Method Alteration Interior Lighting 50% or more replaced Building area No Calculation Adjustments allowed COMPLIES Additional Efficiency Reduced lighting power density credit Options Included Project itle I PSM OFFICE BUILDING TENANT IMPROVEMENTS - 2018 WSEC I 1FDate Jul 01, 2021 ROW Lighting Power Calculation TERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES ompliance Method q1 Building area LPA Calculation Adjustment none Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed Total Proposed Watts Compliance Status by (SF x LPA x 1) By Building Area Building Area Office 1 3,237 1 0.64 1 2,072 961 COMPLIES Proposed Lighting Power Density Fixture Type/Application Fixture ID Building Area New or Existing -to -Remain Quantity of Fixtures, CLDs or Luminaires (#F) Watts per Fixture, or Luminaira (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Direct / indirect pendant P2 Office New 6 35 210 Horizontal surface -mount S2 Office New 15 38 575 Horizontal surface -mount S3 Office New 6 21 126 Horizontal surface -mount S1 Office New 1 15 15 Wall -mounted Wl Office New 4 9 35 Exempt Fixtures Emergency (off when unoccupied) EMI Office New 4 Emergency (off when unoccupied) X Office New 4 RM Project Title-1 PSM OFFICE BUILDING TENANT IMPROVEMENTS - 2018 WSEC I Date I Jul 01, 2021 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (50% or more replaced) Fixture Type/Application Fixture ID Location in Documents lamp Type Building Area New or https://waenergycodes.com/print_project_summary_form.php?k=aWQ9Mzk3NyZmdmk9MTgmY3RpPQ==&print=1 1/2 6/30/2021 https:llwaenergycodes.com/print_project_summary_form.php?k=aWQ9Mzk3NyZmdmk9MTgmY3RpPQ==&print=1 Existing -to -Remain Individual Fixtures Direct / indirect pendant P2 E2.1, E6.1 LED Office New Fixture Description: 6" cylinder Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Horizontal surface -mount S2 I E2.1, E6.1 LED Office New Fixture Description: 1X4 SURFACE MOUNT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Horizontal surface -mount S3 I E2.1, E6.1 LED Office New Fixture Description: 18" SURFACE MOUNT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Horizontal surface -mount SI E2.1, E6.1 I LED Office New Fixture Description: 6" SURFACE MOUNT, WET RATED Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall -mounted WI E2.1, E6.1 LED Office New Fixture Description: WALL MOUNT VANITY LED Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Exempt Fixtures Emergency (off when unoccupied) EMI I E2.1, E6.1 Office New Fixture Description: EMERGENCY LIGHTING Do these fixtures require specific application lighting controls?: Lighting for non -visual applications, independently controlled Emergency (off when unoccupied) X I E2.1, E6.1 Office I New Fixture Description: EXIT SIGN Do these fixtures require specific application lighting controls?: Lighting for non -visual applications, independently controlled https://waenergycodes.com/print_project_summary_form.php?k=aWQ9Mzk3NyZmdmk9MTgmY3RpPQ==&print=1 2/2