Loading...
REVIEWED RESUB1 BLD2022-1726+Interior_Lighting_Summary+2.21.2023_4.26.53_PM+3381102BLD2022-1726 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2023 NEEA, All rights reserved Project & Applicant Information Project Title Burger King #7355 - 2018 WSEC R E S U B Date• Feb 21, 2023 Feb 22 2023 CITY OFEDMONDS DEVELOPMENT SERVICES nPPAPTRAPKIT at REVIEWED BY CITY OF EDMONDS Project Address 7609 212th street S.W. Edmonds, WA 98026 Applicant Name MattSchreifels Applicant Phone 425-252-2153 Applicant Email matts@2812architecture.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Dining, Fast Food Building Cond. Floor Area 2,972 General Project Types Alteration New Building or Addition Lighting Scope g g P Alteration Lighting Scope Interior Lighting Exterior Lighting Project Cond. Floor Area 1,468 Floors Above Grade 1 Compliance Method Compliance Method 1 -General Lighting Project Description Replacing existing interior dining room lighting with new LED fixtures and controls per 2018 WSEC. Exterior canopy lights replaced with new LED fixtures. Lighting Compliance Scope Project Type Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification and Method Alteration Interior Lighting 50% or more replaced Space by space No Calculation Adjustments allowed COMPLIES Alteration Exterior Lighting 50% or more replaced Not applicable to exterior COMPLIES Additional Efficiency Options Included Project'FBurger King #7355 - 2018 WSEC Date Feb 21, 2023 Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Ceding Height (Ft) Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Dining area Family dining 1,468 0.60 881 Dining area Family dining - Ornamental lighting 1,468 0.30 440 166 Restroom General 225 0.63 142 Proposed Total LPD 1 880 Totals 1 1,189 1,046 1 COMPLIES Proposed Lighting Power Density Fixture Type Fixture ID of Fixtures (#F) Fixtures Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Recessed downlight 1 C 1 10 18 180 Recessed downlight C.2 34 10 340 Recessed downlight C 20 1 18 360 Proposed Total LPD 880 Proposed Additional Allowance Lighting (Display/Highlight/Ornamental) Watts or Total Watts Fixture Type Fixture ID General and Specific Space Type Quantity of Wattage Limit Total Linear Watts per Linear Proposed Fixtures (#F) per Fixture Feet (LF) Foot (WpLF) (#F x WpF) or (WpF) (LF x WpLF) Individual Fixtures Suspended A Dining area - Family dining - Ornamental lighting 6 11 66 Suspendedl B I Dining area - Family dining - Ornamental lighting 5 6 30 Wall wash I D I Dining area - Family dining - Ornamental lighting 5 1 14 70 Project Tit a Burger King #7355 - 2018 WSEC Date Feb 21, 2023 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (50% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Recessed downlight C A-4 & D4.0 LED New Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Recessed downlight C.2 A-4 & D4.0 LED New Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Recessed downlight C D4.0 & A-4 LED New Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Project TM7 Burger King #7355 - 2018 WSEC V Date Feb 21, 2023 Lighting Power Calculation ALTERATION - EXTERIOR LIGHTING (5001,. or more replaced) Compliance Verification COMPLIES Exterior Lighting Zone ZONE 2 Base Site Allowance 400 Exterior Tradable Lighting Power Allowance Tradable Surface Tradable Surface Sub -Type Surface Area (SF) LPA (Watts/SF) Linear Feet (LF) LPA (Watts/LF) Total Watts Allowed (LPA x SF) or (LPA x LF) Total Tradable Proposed Watts Tradable Compliance Status Building grounds Walkways < 10 feet wide 28 0.50 14 Building grounds Walkways 10 feet and wider 332 0.10 33 Building entrances and exits Pedestrian entrances & exits 7 14 98 Uncovered parking areas and drives 900 0.04 36 Base Site Allowance 400 Totals 581 546 COMPLIES Proposed Tradable Lighting Power Density Fixture Type Fixture ID Tradable Surface Type Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Canopy M Uncovered parking areas and drives - 3 36 108 Canopy M Building entrances and exits - Pedestrian entrances & exits 1 36 36 Canopy M Building grounds - Walkways < 10 feet wide 4 36 144 Canopy M Building grounds - Walkways 10 feet and wider 3 36 108 Wall -mounted L Building grounds - Walkways < 10 feet wide 1 150 150 Tradable Proposed Total 546 Remaining Base Site Allowance Watts 35.20 Exterior Non -Tradable Lighting Power Allowance Non -Tradable Surface Non -Tradable Surface Sub -Type Surface Area (SF) LPA (Watts/SF) # of Items LPA (Watts per # of items) Total Watts Allowed (LPA x SF) or (LPA x # of Items) Total Non -Tradable Proposed Watts by Surface Type Non -Tradable Proposed Watts Exceeding LPA Non -Tradable Compliance Status Drive -up windows & doors 1 200.00 200 186 Total Proposed Watts Exceeding LPA 0 Remaining Base Site Allowance 35 1 COMPLIES Proposed Non -Tradable Lighting Power Density Fixture Type Fixture ID Tradable Surface Type Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixture Canopy M rive -up windows & doors - 1 36 36 Wall -mounted L Drive -up windows & doors - 1 150 150 Project Ti jqBurger King #7355 - 2018 WSEC Date Feb 21, 2023 Proposed Fixtures Details ALTERATION - EXTERIOR LIGHTING (50%, or more replaced) ML Fixture Type Fixture ID Location in Documents Lamp Type Tradable Surface Type New or Existing -to -Remain Individual Fixtures Canopy M -4 & D4.0 LED Uncovered parking areas and drives - New Fixture Description: Do these fixtures require specific exterior lighting controls?: Canopy M -4 & D4.0 LED Building entrances and exits - Pedestrian entrances & exits New Fixture Description: Do these fixtures require specific exterior lighting controls?: Canopy M 4 & D4.0 LED Building grounds - Walkways < 10 feet wide New Fixture Description: Do these fixtures require specific exterior lighting controls?: Canopy M -4 & D4.0 LED Building grounds -Walkways 10 feet and wider New Fixture Description: Do these fixtures require specific exterior lighting controls?: Wall -mounted L A-4 & D4.0 M tal Halide Building grounds - Walkways < 10 feet wide New Fixture Description: Do these fixtures require specific exterior lighting controls?: Fixture Type Fixture ID Location in Documents Lamp Type Non -Tradable Surface Type New or Existing -to -Remain Individual Fixture Canopy M -4 & D4.0 LED Drive -up windows & doors - New Do these fixtures require specific exterior lighting controls?: Wall -mounted L I A-4 & D4.0 M tal Halide Drive -up windows & doors - New Do these fixtures require specific exterior lighting controls?: