REVIEWED BLD2023-0934+Manufacturer_Specifications_and_Installation_Instructions+7.20.2023_2.29.56_PM+3679733
RECEIVED TR E@ Jul 26 2023 CITY OF EDMONDS BLD2023-0934 DEVELOPMENT SERVICES DEPARTMENT Packaged Rooftops Precedent T11 - R-410A 3-10 Tons - 60 Hz Packaged Cooling, Heat Pumps (T*C, WSC) REVIEWED BY CITY OF EDMONDS 17 Packaged Gas/Electric (Y*C) a ® r January 2009 RT PRCO23-EN 0 T/L411/E Introduction Packaged Rooftop Air Conditioners Figure 1. Packaged Cooling and Heat Pumps Figure 2. Packaged Gas/Electric 1-I 1� Trane customers demand products that provide exceptional reliability, meet stringent performance requirements, and are competitively priced. Trane delivers with Precedent. Precedent features cutting edge technologies: reliable compressors, Trane engineered ReliaTel controls, computer -aided run testing, and Integrated ComfortTl Systems. So, whether you're the contractor, the engineer, orthe owner you can be certain Precedent Products are builtto meet your needs. Through the years, Trane has designed and developed the most complete line of Packaged Rooftop products available in the market today. Trane was the first to introduce the Micro —microelectronic unit controls —and has continued to improve and revolutionize this design concept. Electromechanical controls are available for simpler applications, and for the more sophisticated, ReliaTeIT" microprocessor controls. The ReliaTel control platform offers the same greatfeatures and functionality as the original Micro, with additional benefits for greater application flexibility. With its sleek, compact cabinet, Precedent continues to provide the highest standards in quality and reliability, comfort, ease of service, and the performance of Trane light commercial products. It's Hard To Stop A Trane.® © 2009 Trane All rights reserved RT-PRCO23-EN 0 TIL9NE. Table of Contents Introduction............................................................ 2 Packaged Rooftop Air Conditioners .................................. 2 Features and Benefits ................................................... 5 Standard Features ................................................. 5 Options*.......................................................... 6 Other Benefits ..................................................... 7 Standard Features ................................................. 7 Variety of Options* ................................................ 10 Factory Installed Options* ..................................... 10 Factory or Field Installed Options* .............................. 12 Field Installed Options* ....................................... 13 Other Benefits .................................................... 14 Rigorous Testing ............................................. 16 Application Considerations ............................................. 17 Selection Procedure ................................................... 18 Cooling Capacity ............................................. 18 Heating Capacity.............................................19 Air Delivery Selection ......................................... 19 Model Number Description - 3-10 Ton R-410A ............................ 20 Model Number Notes ......................................... 21 GeneralData.......................................................... 22 Performance Data ..................................................... 36 Direct Drive - Evaporator Fan Performance ............................... 58 Evaporator Fan Performance ........................................... 65 Fan Performance..................................................... 133 Heating Performance Data ............................................. 142 Controls.............................................................148 ReliaTelTI Controlled Units ................................... 148 Electrical Data ........................................................ 151 Jobsite Connections .................................................. 161 Dimensional Data ..................................................... 162 Weights.............................................................174 Mechanical Specifications ............................................. 176 Factory Installed Options ..................................... 177 RT-PRCO23-EN 3 0 M WE' Factory or Field Installed Options .............................. 179 Field Installed Options ....................................... 180 RT-PRCO23-EN 0 TIL9NE. Features and Benefits Standard Features • 5-year Limited Compressor Warranty • 5-year Limited Heat Exchanger Warranty • 1-year Limited Parts Warranty • Anti -Short Cycle Timer (Standard with ReliaTeIT°" ) • Colored and Numbered Wiring • Convertible Airflow • Crankcase Heatersl • Easy Access Low Voltage Terminal Board (LTB) • Electromechanica12 or ReliaTel Microprocessor Controls • Filters are Standard on all Units • Foil -Faced and Edge Captured Insulation • High Pressure Control • IAQ Dual Sloped and Removable Drain Pans • Liquid Line Refrigerant Drier • Low Ambient Cooling to 0°F on Microprocessor Models • Low Ambient Cooling to 40°F on Electromechanical Models • Low Pressure Control • Multispeed Direct Drive Motors • Operating Charge of R-410A • Patent -Pending Hybrid Condenser Coil for easy cleaning • Phase Reversal Protection3 • Progressive Tubular Aluminized Steel Heat Exchanger • Provisions for Through -the -Base Gas and Condensate Drain Connections • Quick Access Panels • Quick Adjust Fan Motor Mounting Plate • Single Point Power • Single Side Service • Standardized Components • Thermal Expansion Valve • Trane built Scroll Compressors 1 Crankcase heaters are optional on: (Y, T)SC(036,048,060)E, WSC036E, WSC048E1, WSC060E1 2 Not available for Heat Pumps 3 Only available for 3-5 Ton Direct Drive RT-PRCO23-EN 5 0 M WE' Features and Benefits Options* Note: *Refer to Model Number Description for option availability. Factory Installed Options • Belt Drive Motorsl (Three-phase) • Black Epoxy Pre -Coated Coils • CompleteCoatTM Condenser Coil • Hinged Access Doors • Novar Return Air Sensor • Novar Unit Controls • Phase Monitor • Powered or Unpowered Convenience Outlet • Stainless Steel Heat Exchanger with 10-year warranty • Supply and/or Return Air Smoke Detector • Through the Base Electrical Access • Through the Base Electrical with Circuit Breaker • Through the Base Electrical with Disconnect Switch • 2" MERV 7 Filters or 2" MERV 13 Filters Factory or Field Installed Options • Barometric Relief • Clogged Filter/Fan Failure Switch • Crankcase Heaters • Discharge Air Sensing Kit • Economizer • Electric Heaters • Frostat • LonTalk® Communications Interface (LCI) • Reference or Comparative Enthalpy • Tool -less Hail Guards • Trane Communications Interface (TCI) Field Installed Options • CO2 Sensing • Dual Thermistor Remote Zone Sensor • High Altitude Kit • High Static Drive • LP Conversion Kit • Manual Outside Air Damper • Motorized Outside Air Dampers 1 Standard for 6-10 Ton 6 RT-PRCO23-EN 0 caws" Features and Benefits • Powered Exhaust • Quick Adapt Curbs • Quick Start Kit • Remote Potentiometer • Roof Curb • Thermostat • Ventilation Override Accessory • Zone Sensor Other Benefits • Cabinet design ensures water integrity • Ease of Service, Installation and Maintenance • Mixed model build enables "fastest in the industry" ship cycle times • Outstanding Airflow Distribution • ReliaTel Controls • Unmatched Product Support is one of our finest assets. Trane Sales Representatives are a Support Group that can assist you with: • Product • Application • Service • Training • Special Applications • Specifications • Computer Programs and much more Standard Features Anti -Short Cycle Timer (Standard with ReliaTel) Provides a 3 minute minimum "ON" time and 3 minute "OFF" time for compressors to enhance compressor reliability by assuring proper oil return. Direct Drive Motors For additional static requirements, single-phase 13 SEER and 15 SEER R-410A units offer multi - speed, direct drive motors. Colored And Numbered Wiring Save time and money tracing wires and diagnosing the unit. RT-PRCO23-EN 7 0 M WE' Features and Benefits Compressors Precedent contains the best compressor technology available to achieve the highest possible performance. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on all models and allow for efficient cooling utilizing 3-stages of compressor operation (high efficiency models only). Controls - ReliaTel or Electromechanical Condenser Coil Precedent boasts a patent -pending 1+1+1 condenser coil, permanently gapped for easy cleaning. ReliaTel microprocessor controls provide unit control for heating, cooling and ventilating utilizing inputfrom sensors that measure indoor and outdoor temperature and otherzone sensors. ReliaTel also provides outputs for building automation systems and expanded diagnostics. For a complete list of ReliaTel offerings, refer to the "Other Benefits" section within the Features and Benefits section of this catalog. For the simpler job that does not require a building automation system, or expanded diagnostics capabilities, Precedent offers electromechanical controls. This 24-volt control includes the control transformer and contactor pressure lugs for power wiring. Convertible Units The units ship in a downflow configuration. They can be easily converted to horizontal by simply moving two panels. Units come complete with horizontal duct flanges so the contractor doesn't have to field fabricate them. These duct flanges are a time and cost saver. Cooling Standard or High Efficiency cooling available. Crankcase Heaters These band heaters provide improved compressor reliability by warming the oil to prevent migration during off -cycles or low ambient conditions. RT-PRCO23-EN 0 laws" Dual Drain Pans Features and Benefits Every Precedent unit has a non -corrosive, removable, double - sloped drain pan that's easy to clean and reversible to allow installation of drain trap on either side of the unit. Easy Access Low Voltage Terminal Board Foil Faced Insulation Precedent's Low Voltage Terminal Board is external All panels in the evaporator section of the to the electrical control cabinet. It is extremely easy unit have cleanable foil -faced insulation. to locate and attach the thermostat wire and test All edges are either captured or sealed to operation of all unit functions. This is another cost ensure no insulation fibers get into the and time saving installation feature. airstream. Heat Exchanger The compact cabinet features a progressive tubular heat exchanger in low, medium and high heat capacities. The heat exchanger is fabricated using stainless steel burners and corrosion -resistant aluminized steel tubes as standard on all models. It has an induced draft blowerto pull the gas mixturethrough the burner tubes. The heater has a direct spark ignition system which doubles as a safety device to prove the flame. Gas/Electric Precedent models exceed all California seasonal efficiency requirements. They also perform better than required to meet the California NOx emission requirements. High Pressure Control All units include High Pressure Control as standard. Low Ambient Cooling All Precedent microprocessor units have cooling capabilities down to 0°F as standard. Electromechanical models have cooling capabilities to 40°F as built, orto 0°F by adding the optional low ambient control (frostat). The wiring of the low voltage connections to the unit and the zone sensors is as simple as 1-1, 2-2, and 3-3. This simplified system makes it easy for the installer to wire. RT-PRCO23-EN 0 7NME' Features and Benefits Phase Reversal Protection Precedent units with 3-phase power and direct drive supply fan motors (3-5 ton) are equipped with phase reversal protection. This feature shall provide 100% protection for compressor against problems caused by phase reversal. Quick -Access Panels Remove two screws for access to the standardized internal components and wiring. Quick -Adjust Idler Arm With the Quick -Adjust Idler Arm, the belt and sheaves can be quickly adjusted without moving the mounted fan motor. The result is a major savings in time and money. Single Point Power A single electrical connection powers the unit. Single Side Service Single side service is standard on all units. Standardized Components Components are placed in the same location on all Precedent units. Familiarize yourself with one Precedent and you are familiar with every Precedent. Due to standardized components throughout the Precedent line, contractors/owners can stock fewer parts. Thermal Expansion Valve This feature is standard on all units. Through the Base Condensate Every unit includes provisions forthrough the base condensate drain connections. This allows the drain to be connected through the roof curb instead of a roof penetration. Variety of Options* Factory Installed Options* Note: *Refer to Model Number Description for option availability. Belt Drive Motors (Three-phase) For additional static requirements, Precedent 3-5ton units offer an optional belt drive motor to meet a wide range of airflow needs. Black Epoxy Pre -Coated Coils The pre -coated coils are an economical option for protection in mildly corrosive environments. CompleteCoatTM Condenser Coil These coils provide excellent corrosion resistance as well as uniformity of coverage and coating thickness. 10 RT-PRCO23-EN 0 laws" Features and Benefits Disconnect Switch (Available with Through -the -Base Electrical) Factory installed 3-pole, molded case, disconnect switch with provisions for through the base electrical connections are available. Codes require a method of assured unit shutdown for servicing. Field -installed disconnects sometimes interfere with service access. Factory installation of unit disconnects reduces costs, assures proper mounting and provides the opportunity to upgrade to unit circuit breaker protection. Circuit Breaker (Required with Through- the -Base Electrical) EW Unit Mounted Disconnect or Circuit Breaker �� Convenient /I Outlet C This option is a factory installed thermal magnetic, molded case, HACR Circuit Breaker with provisions for through the base electrical connections. Novar Unit Controls Hinged Access Doors These doors permit easy access to the filter, fan/heat, and compressor/control sections. They reduce the potential roof damage from screws or sharp access door corners. Novar 3051 and 2024 are available for Precedent Gas and Electric Heat models. Phase Monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. Powered or Unpowered Convenience Outlet This option is a GFCI, 120V/15amp, 2 plug, convenience outlet, either powered or unpowered. This option can only be ordered when Through the Base Electrical with either the Disconnect Switch or Circuit Breaker option is ordered. Stainless Steel Heat Exchanger The optional stainless steel heat exchanger is constructed of 409 stainless steel. It is resistant to corrosion and oxidation and easy to clean. The high strength to weight ratio allows for high ventilation rates with gas units. It is an excellent option to compliment the dehumidification option as a high outside air ventilation unit. With this option, a 10-year stainless steel heat exchanger warranty is standard. RT-PRCO23-EN 11 0 M WE' Features and Benefits Supply and/or Return Air Smoke Detector With this option installed, if smoke is detected, all unit operation will be shut down. Reset will be manual at the unit. Return Air Smoke Detectors require minimum allowable airflow when used with certain models. Factory or Field Installed Options' Through -the -Base Electrical Utility Access An electrical service entrance shall be provided allowing electrical access for both control and main power connections inside the curb and through the base of the unit. Option will allow for field installation of liquid -tight conduit and an external field installed disconnect switch. Factory provided through the base openings simplify wiring and piping. Because these utility openings frequently minimize the number of roof penetrations, the integrity of roofing materials is enhanced. Note: *Refer to Model Number Description for option availability. Barometric Relief Designed to be used on downflow units, barometric relief is an unpowered means of relieving excess building pressure. Clogged Filter/Fan Failure Switch A dedicated differential pressure switch is available to achieve active fan failure indication and/or clogged filter indication. These sensors allow a zone sensor service light or Integrated Comfort System to indicate a dirty filter or a fan that's not working. The field installation charges for these valuable feedback devices often eliminate them from consideration. Factory installation can make such features a good investment. Crankcase Heaters These band or insertion heaters provide improved compressor reliability by warming the oil to prevent migration during off -cycles or low ambient conditions. Discharge Air Sensing Kit Provides true discharge air sensing in heating models. The kit is functional only with the ReliaTel Options Module. Electric Heaters Electric heat modules are available within the basic unit. If ordering the Through the Base Electrical option with an Electrical Heater, the heater must be factory installed. Fresh Air Options - Dampers and Economizer 0 - 25% manual or 0 - 50% motorized outside air hoods are available. 12 RT-PRCO23-EN 0 laws" Features and Benefits Economizers are equipped with either dry bulb or reference or comparative enthalpy sensing. These economizers provide free cooling as the outdoor temperature and/or humidity decreases. Correctly installed, they offer a valuable energy savings. Factory -installed economizers save time and ensure proper installation. The economizers come with three control options — dry bulb is standard, enthalpy and differential enthalpy are optional. Frostat This capillary bulb embedded in the face of the evaporator coil monitors coil temperature to prevent evaporator icing and protect the compressor. Recommended for applications with low leaving air temperatures, low airflow and or high latent load applications. LonTalk® Communications Interface The LonTalk communications interface allows the unit to communicate as a TracerT" LCI-V device or directly with generic LonTalkNetwork Building Automation System Controls. Reference or Comparative Enthalpy Measures and communicates humidity while maximizing comfort control. Tool -less Hail Guards _ . m. A� Tool -less, hail protection quality coil guards shall be either j factory or field -installed for condenser coil protection. This • option protects the condenser coil from vandalism and/or hail damage. i Trane Communication Interface (TCI) Available factory or field installed. This module when applied with the ReliaTeIT" easily interfaces with Trane's Integrated ComfortTl System. Field Installed Options* Note: *Refer to Model Number Description for option availability. CO2 Sensing The CO2 sensor hasthe abilityto monitorspace occupancy levelswithin the building by measuring the parts per million of CO2 (Carbon Dioxide) in the air. As the CO2 levels increase, the outside air damper modulatesto meet the CO2 space ventilation requirements. The CO2 sensor kit is available as a field installed accessory. Dual Thermistor Remote Zone Sensor This sensor will reduce the total number of remote sensors to obtain space temperature averaging. This sensor should be utilized with ReliaTel controls. High Altitude Kit Previously a Canadian Agency requirement for units applied about 2000 feet, it is not required by the U.S. Domestic contractors should consult with local authority on best practice. Derates gas orifices by 10%. RT-PRCO23-EN 13 0 7NME' Features and Benefits High Static Drive Available on many models, this high static drive accessory extends the capability of the standard motor. Avoid expensive motors and operating costs by installing this optimized sheave accessory. LP Conversion Kit Provided for field conversion of gas/electric units from Natural gas to Propane. Quick Adapt Curbs Enables easy conversion of existing Voyager 3-10 ton units to Precedent units on replacement jobs. Quick Start Kits Single phase equipment to enable startup and prevent building lighting dimming during low voltage. Roof Curbs Available for downflow units. Only two roof curbs for the entire line simplifies curb selection. Remote Potentiometer When properly installed in the economizer control circuitry, this accessory provides a remote variable resistance to enable the operator to adjust the minimum damper position. Ventilation Override Accessory With the Ventilation Override Accessory installed,the unit can be setto transition to upto 3 different pre-programmed sequences for Smoke Purge, Pressurization, and Exhaust. The transition occurs when a binary input on the RTOM is closed (shorted). This would typically be a hard wired relay outputfrom a smoke detector orfire control panel. The ventilation override kit is available as a field installed accessory. Zone Sensors/Thermostats Available in programmable, automatic and manual styles. Other Benefits Airflow Distribution Airflow is outstanding. Precedent can replace an older machine with old ductwork and, in many cases, improve the comfort through better air distribution. Cabinet Integrity For added water integrity, Precedent has a raised 1 1/8" lip around the supply and return of the downflow units to prevent water from blowing into the ductwork. Easy to Install, Service and Maintain Because today's owners are very cost-conscious when it comes to service and maintenance, the Trane Precedent was designed with direct inputfrom service contractors. This valuable information helped to design a product that would getthe service person off thejob quickerand savethe owner money. Precedent offers outstanding standard features enhanced by a variety of factory and field installed options, multiple control options, rigorously tested proven designs and superior product and technical support. 14 RT-PRCO23-EN Features and Benefits Flexibility Precedent offers ultimate flexibility. Units are built to order in our standard "shortest in the industry" ship cycle time. ReliaTellrl Controls ReliaTel controls provide unit control for heating, cooling and AIL ventilating utilizing input from sensors that measure outdoor and indoor temperature. ReliaTel Control Logic Enhances Quality and Reliability — prevents the unit from short cycling, considerably improving compressor life. — ensures that the compressor will run for a specific amount of time which allows oil to return for better lubrication, enhancing the reliability of the compressor. Precedent units with ReliaTel reduces the number of components required to operate the unit, thereby reducing possibilities for component failure. ReliaTel Makes Installing and Servicing Easy ae;f ReliaTel eliminates the need forfield installed anti-shortcycle timer and time delay relays. ReliaTel eliminates the need forfield installed anti-shortcycle timer and time delay relays. ReliaTel controls provide these functions as an integral part of the unit. The contractor no longer has to purchase these controls as options and pay to install them. The wiring of the low voltage connections to the unit and the zone sensors is as easy as 1-1, 2-2, and 3-3. This simplified system makes wiring easier for the installer. ReliaTel Makes Testing Easy ReliaTel requires no special tools to run the Precedent unitthrough its paces. Simply place a jumper between Test 1 and Test 2 terminals on the Low Voltage Terminal Board and the unit will walk through its operational steps automatically. The unit automatically returns control to the zone sensor after stepping through the test mode a single time, even if the jumper is left on the unit. As long as the unit has power and the "system on" LED is lit, ReliaTel is operational. The light indicates that the controls are functioning properly. ReliaTel features expanded diagnostic capabilities when utilized with Trane Integrated ComfortTl Systems. Some zone sensor options have central control panel lights which indicate the mode the unit is in and possible diagnostic information (dirty filters for example). Other ReliaTel Benefits The ReliaTel built-in anti-shortcycle timer, time delay relay and minimum "on" time control functions are factory tested to assure proper operation. ReliaTel softens electrical "spikes" by staging on fans, compressors and heaters. Intelligent Fallback is a benefitto the building occupant. If a componentfails, the unitwill continue to operate at predetermined temperature setpoint. Intelligent Anticipation is a standard ReliaTel feature. Itfunctions continuouslyas ReliaTel and zone sensor(s) work together in harmony to provide much tighter comfort control than conventional electro-mechanical thermostats. RT-PRCO23-EN 15 0 7NME' Features and Benefits Rigorous Testing The same ReliaTel Board fits all Packaged Gas/Electric, Cooling with Electric Heat, and Heat Pump models. This provides standardization of parts for contractors. Less money is tied up in inventory with ReliaTel. Unit Cabinet The compact cabinet with rounded corners takes up less room and is less costly to ship. The beveled and ribbed top is not only aesthetically pleasing, it is designed to prevent water from pooling. VariTrac — Building Automation System When Trane's changeover VAV System for Roof Top Unit light commercial applications is coupled with = Precedent, it provides the latest in technological advances for comfort management systems and can allow II thermostat control in every zone served by VariTrac. to II�i ii� II PI All of Precedent's designs were rigorously rain tested at the factory to ensure water integrity. Actual shipping tests were performed to determine packaging requirements. Units were test shipped around the country to determine the best packaging. Factory shake and drop tests were used as part of the package design process to help assure that the unit arrives at the job site in top condition. Rigging tests include lifting a unit into the air and letting it drop one foot, assuring that the lifting lugs and rails hold up under stress. We perform a 100% coil leaktest at the factory. The evaporator and condenser coils are leak tested at 575 psig and pressure tested to 450 psig. All parts are inspected atthe point of final assembly. Sub -standard parts are identified and rejected immediately. Every unit receives a 100% unit run test before leaving the production line to make sure it lives up to rigorous Trane requirements. 16 RT-PRCO23-EN 0 TIL9NE. Application Considerations Application of this product should be within the cataloged airflow and cooling considerations. Barometric Relief This product line offers an optional barometric relief damper for use in conjunction with economizer option. This accessory consists of gravity dampers which open with increased pressure. As the building air pressure increases, the pressure in the unit return air section also increases, opening the dampers and relieving the conditioned space. Note: The effectiveness of barometric relief damper during economizing operation is system related. Pressure drop of the return air system should be considered to control building pressurization. Black Epoxy Coil The coils are manufactured with a thermoset, vinyl coating that is bonded to the aluminum fin stock prior to the fin stamping process. These coils are an economical option for protection in mildly corrosive environments. Note: Not to be used where seacoast applications exist. Clearance Requirements The recommended clearances identified with unit dimensions should be maintained to assure adequate service maximum capacity and peak operating efficiency. Actual clearances which appear inadequate should be reviewed with the local Trane sales personnel. CompleteCoatT'" Condenser Coil The coils provide protection from corrosive environments and are ideal for seacoast applications. Condensate Trap The evaporator is a draw-thru configuration. A trap must be field provided prior to start-up on the cooling cycle. Heating Operation The heat exchanger is manufactured with aluminized steel. To prevent condensation within the heat exchanger, do not exceed 50% outside air or a minimum mixed air temperature of 40°F. Low Ambient Cooling The PrecedentTl line features, with ReliaTe IT' microprocessor controls, low ambient cooling down to 0°F. With electromechanical controls, Precedent features low ambient cooling to 40OF. The following features or options need to be included/considered when low ambient applications are required: continuous fan operation, crankcase heaters, thermal expansion valves, frostat. Contact your local Trane Representative for more assistance with low ambient cooling applications. Optional Stainless Steel Heat Exchanger The optional stainless steel heat exchanger is manufactured with 409 stainless steel. To prevent corrosion and prolong heat exchanger reliability, the minimum mixed air temperature allowed across the heat exchanger is 20°E. Whenever high outside air or outside applications exist, these options should be utilized. Unit Pitch These units have reversible sloped condensate drain pans. Units must be installed level. Any unit slope must be toward the side of unit where condensate drain is connected. RT-PRCO23-EN 17 0 T/L411/E Selection Procedure Cooling Capacity Note: Cooling Capacity Procedure is the same for electric heat (T*C) and gas heat (Y*C). Step 1. Calculate the building's total and sensible cooling loads at design conditions. Use the Trane calculation methods or any other standard accepted method. Factors used in unit selection: • Packaged Cooling with Optional Electric Heat • Total Cooling Load: 59 MBh • Sensible Cooling Load: 40 MBh • Airflow: 2000 cfm • Electrical Characteristics: 460/60/3 • Summer Design Conditions: Entering Evaporator Coil: 80 DB • 67 WB Outdoor Ambient: 95 • External Static Pressure: 0.36 in. wg • Downflow Configuration • Efficiency: 13 SEER • Economizer Step 2. As a starting point, a rough determination must be made of the size of the unit. The final selection will be made after examining the performance atthe given conditions. Divide the total cooling load by nominal Btuh per ton (12 MBh per ton); then round up to the nearest unit size. 59 MBh / 12 MBh = approx. 5 tons Step 3. Table 13, p. 41 shows that a TSC060E4 has a gross cooling capacity of 62.3 MBh and 48.1 MBh sensible capacity at 2000 cfm and 95 DB outdoor ambient with 80 DB, 67 WB air entering the evaporator. To Find Capacity at Intermediate Conditions not in the table. When the design conditions are between two numbers that are in the capacity table, interpolation is required to approximate the capacity. Note: Extrapolation outside of the table conditions is not recommended. Step 4. In orderto selectthe correct unitwhich meetsthe building's requirements, thefan motor heat must be deducted from the gross cooling capacity. The amount of heat that the fan motor generates is dependent on the effort by the motor - cfm and static pressure. To determine the total unit static pressure: External Static Duct System 0.36 wg Standard Filter 2 in. from 0.049 wg Table 115, p. 137 Economizer from Table 115, p. 137 (100% Outside Air) 0.105 wg *worst case Electric Heater Size 6 M 0.021 wg from Table 115, p. 137 (reference "Heating Capacity" section on this page for determination of heater size) Total Static Pressure 0.535 wg Note: The Evaporator Fan Performance Table 34, p. 62 has deducted the pressure drop for a filter already in the unit (see note below Table 34, p. 62). Therefore, the actual total static pressure is 0.535 -0.049 (from Table 115, p. 137) = 0.486 wg. 18 RT-PRCO23-EN 0 laws" Selection Procedure With 2000 cfm and 0.5 wg. Table 34, p. 62 shows 0.575 bhp for this unit. Note: Below the table is the formula to calculate Fan Motor Heat 2.87 x bh p + 0.75 = M Bh. 2.87 x 0.575 + 0.15 = 1.8 MBh. Now subtract the fan motor heat from the gross cooling capacity of the unit: Net Total Cooling Capacity = 62.3 MBh - 1.8 = 60.5 MBh. Net Sensible Cooling Capacity =48.1 MBh - 1.8 = 46.3 MBh. Subtracting Sensible from Total Capacity to find Latent Capacity Net Latent Capacity = 60.5 - 46.3 = 14.2 M B h. Step 5. Compare your resulting capacities to the building load. If the performance will not meet the required load of the building's total or sensible cooling load, try a selection at the next higher size unit. Heating Capacity Note: Heating capacity procedure DIFFERS for electric heat (T*C) and gas heat (Y*C) units Step 1. Calculate the building heating load using the Trane calculation form or other standard accepted method. Step 2. Size the system heating capacity to match the calculated building heating load. The following are building heating requirements: Total heating load of 15 MBh 2000 cfm T*C units with optional electric heat: 460V/3 phase Power Supply The electric heat accessory capacities are listed in Table 118, p. 139. From the table, a 6 kW heater will deliver 20.48 MBh at 480 volts. In order to determine capacity at 460 volts, the heater voltage correction factor from Table 120, p. 140 must be used. Therefore, 20.48 MBh x 0.918 (voltage correction factor) = 18.8 MBh. Y*C units with gas heat: Fuel- natural gas. 60 MBh, 80 MBh and 130 MBh input models shown in Table 116, p. 137. The output capacities of these furnaces are 48 MBh, 64 MBh and 104 MBh respectively. The low heat model with 48 MBh best matches the building requirements. Air Delivery Selection Note: Air Delivery procedure is the same for electric heat and gas heat units.► External static pressure drop through the air distribution system has been calculated to be 0.5 inches of water. Enter Table 54, p. 82 for a TSC063E4 at 2000 cfm and 0.5 static pressure. The standard direct drive motor will give the desired airflow at a rated bhp of 0.73 and 951 rpm. RT-PRCO23-EN 19 0 T/L411/E Model Number Description - 3-10 Ton R-410A Digit 1 - Unit Type T DX Cooling Y DX Cooling, Gas Heat W Packaged Heat Pump2,4 Digit 2 - Efficiency S Standard Efficiency (13 SEER R-410A) H High Efficiency (15 SEER R-410A) Digit 3 - Airflow C Convertible Digit 4,5,6 - Nominal Gross Cooling Capacity (MBh) 036 3 Tons 048 4 Tons 060 5 Tons 072 6 Ton 090 71/2 Ton, Single Compressor 092 71/2 Ton, Dual Compressor 102 81/2 Ton 120 10 Ton Digit 7 - Major Design Sequence E R-410A Refrigerant Digit 8 - Voltage Selection 1 208/230/60/1 3 208-230/60/3 4 460/60/3 W 575/60/3 Digit 9 - Unit Controls E Electromechanical' R ReliaTeIT"° Microprocessor Digit 10 - Heating Capacity O=No Electric Heat E=12 kW (3 phase) A=5 kW (1 phase)2 F=14 kW (1 phase)2 B=6 kW (3 phase) G=18 kW (1&3 phase) D=10 kW (1 phase)2 J=23 kW (3 phase) Note: Applicable to Digit 1, Y models only. L Low M Medium H High X Low, Stainless Steel Heat Exchanger Y Medium, Stainless Steel Heat Exchanger Z High, Stainless Steel Heat Exchanger Digit 11 - Minor Design Sequence A First Sequence Digit 12,13 - Service Sequence ** Factory Assigned Digit 14 - Fresh Air Selection 0 No Fresh Air A Manual Outside Air Damper 0-50%5 B Motorized Outside Air Damper 0-50% C Economizer, Dry Bulb 0-100% without Barometric Relief$ D Economizer, Dry Bulb 0-100% with Barometric Relief$ E Economizer, Reference Enthalpy 0-100% without Barometric Relief4,8 F Economizer, Reference Enthalpy 0-100% with Barometric Relief4,8 G Economizer, Comparative Enthalpy 0-100% without Barometric Relief4,8 H Economizer, Comparative Enthalpy 0-100% with Barometric Relief4,s Digit 15 - Supply Fan/Drive Type/ Motor 0 Standard Drivel 2 Optional Belt Drive Motor20 Digit 16 - Hinged Service Access/ Filters 0 Standard Panels/Standard Filters A Hinged Access Panels/Standard Filters B Standard Panels/2" MERV 7 Filters C Hinged Access Panels/2" MERV 7 Filters D Standard Panels/2" MERV 13 Filters E Hinged Access Panels/2" MERV 13 Filters Digit 17 - Condenser Coil Protection 0 Standard Coil 1 Standard Coil with Hail Guard 2 Black Epoxy Pre -Coated Condenser Coil 3 Black Epoxy Pre -Coated Condenser Coil with Hail Guard 4 CompleteCoatT" Condenser Coil 5 CompleteCoatTM Condenser Coil with Hail Guard Digit 18 - Through the Base Provisions Note: Applicable to Digit 1,TorYmodels 0 No Through the Base Provisions A Through the Base Electric9 Note: Applicable to Digit 1, Y models only B Through the Base Gas Piping C Through the Base Electric and Gas Piping17 Digit 19 - Disconnect/Circuit Breaker/Phase Monitor (three- phase only) 0 No Disconnect/No Circuit Breaker No Phase Monitor2l 1 Unit Mounted Non -Fused Disconnects 2 Unit Mounted Circuit Breakers 3 Phase Monitor21,22 4 Phase Monitor & Non -Fused Disconnect Switch9,21,22 5 Phase Monitor & Circuit Breaker9,21,22 Digit 20 - Convenience Outlet 0 No Convenience Outlet A Unpowered Convenience Outlet B Powered Convenience Outlet (three-phase only)10 Digit 21 - Communications Options4 0 No Communications Interface 1 Trane Communications Interface 2 LonTalk® Communications Interface 3 Novar 2024 Controls' 4 Novar 3051 Controls without Zone Sensorl Digit 22 - Refrigeration System Option 0 Standard Refrigeration Systemll Digit 23 - Refrigeration Controls Note: Applicable to Digit 7 = E 0 No Refrigeration Contro16 1 Frostat12 2 Crankcase Heater3 3 Frostat12 and Crankcase Heater3 Digit 24 - Smoke Detector18 0 No Smoke Detector A Return Air Smoke Detector13,14 B Supply Air Smoke Detector C Supply and Return Air Smoke Detectors13,14 Digit 25 - Monitoring Controls 0 No Monitoring ControI15 1 Clogged Filter Switch15 2 Fan Failure Switch15 3 Discharge Air Sensing Tube15 4 Clogged Filter Switch and Fan Fail Switch15 5 Clogged Filter Switch and Discharge Air Sensing Tube15 6 Fan Fail Switch and Discharge Air Sensing Tube15 7 Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube15 8 Novar Return Air Sensor16 9 Novar 3051 Zone Sensor23 20 RT-PRCO23-EN 0 7NME' Model Number Notes 1. Not available for 3-5 tons, R-410A Heat Pumps. 2. Available on 3-5 Standard Efficiency. 3. Standard on all 15 SEER and 4-5 Ton E3,4,W Heat Pumps and all 6-10 Ton units. 4. Not available with electromechanical controls. 5. Manual outside air damper will ship factory supplied within the unit, but must be field installed. 6. High pressure control is standard on all units. 7. Multispeed direct drive standard on single-phase and 15 SEER products. Belt drive standard on three-phase 13 SEER and 6-10 Ton products. 8. Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric Relief for horizontal configured units must be ordered as field installed accessory. 9. Throughthe base electric required when ordering disconnect/circuit breaker options. 10. Requires use of Disconnect or Circuit Breaker. 11. Standard metering devices are TXVs. 12. Frostat cannot be field installed in electro-mechanical units. 13. The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory. 14. Return AirSmoke Detectorcannot be ordered with Novar Controls. 15. These options are standard when ordering Novar Controls. Model Number Description - 3-10 Ton R-41OA 16. This option is used when ordering Novar Controls. 17. Includes gas piping and shutoff (field assembly required). 18. Not available with high temperature duct sensor accessory. 19. Requires hinged access panels. 20. Belt Drive optional on three-phase 15 SEER, R-410A units. 21. Phase Reversal protection is standard on 3-5 ton units with Direct Drive and 3 phase power. 22. Available on Belt Drive (3-10) tons. 23. Novar Sensor utilized with Digit 21 = (4) Novar 3051 Controls without Zone Sensor. RT-PRCO23-EN 21 0 TRINE" General Data Table 1. General data - 3-4 tons - standard efficiency 3 Tons 4 Tons T/YSC036E1 T/YSC036E3,4,W T/YSC048E1 T/YSC048E3,4,W Cooling Performance(a) Gross Cooling Capacity 35,620 37,150 49,210 49,450 SEER(b) 13.0 13.0 13.0 13.0 Nominal cfm/ARI Rated cfm 1,200/1,200 1,200/1,200 1,600/1,600 1,600/1,600 ARI Net Cooling Capacity 35,000 35,800 48,000 48,000 System Power (kW) 3.04 3.20 4.32 4.39 Compressor Number/Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll Sound Outdoor Sound Rating (dB)(0 81 81 82 82 Outdoor Coil Type Lanced Lanced Lanced Lanced Tube Size (in.) OD 0.3125 0.3125 0.3125 0.3125 Face Area (sq. ft.) 10.96 9.59 10.96 10.96 Rows/FPI 2/17 2/17 2/17 2/17 Indoor Coil Type Lanced Lanced Lanced Lanced Tube Size (in.) 0.3125 0.3125 0.3125 0.3125 Face Area (sq. ft.) 7.71 7.71 7.71 7.71 Rows/FPI 3/16 3/16 4/16 4/16 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Drain Connection Number/Size (in.) 13/4 NPT 13/4 NPT 13/4 NPT 13/4 NPT Outdoor Fan Type Propeller Propeller Propeller Propeller Number Used/Diameter (in.) 1/22 1/22 1/22 1/22 Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 cfm 3,466 3,375 3,411 3,403 Motor hp 0.33 0.33 0.33 0.33 Motor rpm 1,075 1,075 1,075 1,075 Indoor Fan Type (Standard) FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal Number Used/Diameter (in.) 1/11XI1 1/11XI1 1/11XI1 1/11XI1 Drive Type/Number Speeds Direct/5 Belt/Variable Direct/5 Belt/Variable Number Motors 1 1 1 1 Motor hp 0.75 1.0 1.0 1.0 Motor Frame Size 48 56 48 56 Filters(d) Type Furnished Throwaway Throwaway Throwaway Throwaway Number Size Recommended (2) 20x30x1 (2) 20x30x1 (2) 20x30x1 (2) 20x30x1 Refrigerant Charge(e) Pounds of R-410A 6.3 6.3 7.4 7.4 continued on next page 22 RT-PRCO23-EN A TRANE General Data Table 1. General data - 3-4 tons - standard efficiency (continued) 3 Tons 4 Tons T/YSC036E1 T/YSC036E3,4,W T/YSC046E1 T/YSC046E3,4,W Heating Performance(f) (Gas/Electric Only) Heating Input Low Heat Input (Btu) 60,000 60,000 60,000 60,000 Mid Heat Input (Btu) 80,000 80,000 80,000 80,000 High Heat Input (Btu) 120,000 120,000 120,000 120,000 Heating Output Low Heat Input (Btu) 48,000 48,000 49,000 48,000 Mid Heat Input (Btu) 65,000 64,000 65,000 64,000 High Heat Input (Btu) 96,000 96,000 96,000 96,000 AFUE%(9) Low Heat Input (Btu) 78 80 79 80 Mid Heat Input (Btu) 78 80 79 80 High Heat Input (Btu) 78 80 79 80 Steady State Efficiency% Low Heat Input (Btu) 80 80 81 80 Mid Heat Input (Btu) 81 80 81 80 High Heat Input (Btu) 80 80 80 80 No. Burners Low Heat Input (Btu) 2 2 2 2 Mid Heat Input (Btu) 2 2 2 2 High Heat Input (Btu) 3 3 3 3 No. Stages Low Heat Input (Btu) 1 1 1 1 Mid Heat Input (Btu) 1 1 1 1 High Heat Input (Btu) 1 1 1 1 Gas Supply Line Pressure Natural (minimum/maximum) 4.5/10.5 4.5/10.5 4.5/10.5 4.5/10.5 LP (minimum/maximum) 10.0/13.0 10.0/13.0 10.0/13.0 10.0/13.0 Gas Connection Pipe Size (in) Low Heat 1/2 1/2 1/2 1/2 Mid Heat 1/2 1/2 1/2 1/2 High Heat 1/2 1/2 1/2 1/2 (a) Cooling performance is rated at 950F ambient, 80OF entering dry bulb, 670F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz). (b) EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. (c) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For additional information refer to Table 109, p. 134. (d) Optional 2" MERV 7 and MERV 13 filters also available. (e) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. (f) Heating performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Applicable to Gas/Electric units only. (g) AFUE is rated in accordance with DOE test procedures. RT-PRCO23-EN 23 TRAWE WF General Data Table 2. General data - 5 tons - standard efficiency 5 Tons T/YSC060E1 T/YSC060E3,4,W Cooling Performance(a) Gross Cooling Capacity 59,900 62,270 SEER(b) 13.0 13.0 Nominal cfm/ARI Rated cfm 2,000/2,000 2,000/2,000 ARI Net Cooling Capacity 58,000 60,000 System Power (kW) 5.25 5.46 Compressor Number/Type 1/Scroll 1/Scroll Sound Outdoor Sound Rating (dB)(0 82 82 Outdoor Coil Type Lanced Lanced Tube Size (in.) 0.3125 0.3125 Face Area (sq. ft.) 10.96 10.96 Rows/FPI 3/17 3/17 Indoor Coil Type Lanced Lanced Tube Size (in.) 0.3125 0.3125 Face Area (sq. ft.) 7.71 7.71 Rows/FPI 4/16 4/16 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Drain Connection Number/Size (in.) 13/4 NPT 13/4 NPT Outdoor Fan Type Propeller Propeller Number Used/Diameter (in.) 1/22 1/22 Drive Type/No. Speeds Direct/1 Direct/1 cfm 3,271 3,245 Number Motors/hp 0.40 0.40 Motor rpm 1,075 1,075 Indoor Fan Type (Standard) FC Centrifugal FC Centrifugal Number Used/Diameter (in.) 1/11XI1 1/1Ix1I Drive Type/Number Speeds Direct/5 Belt/Variable Motor hp 1.0 1.0 Motor Frame Size 48 56 Filters(d) Type Furnished Throwaway Throwaway Number Size Recommended (2) 20x30x1 (2)20x30x1 Refrigerant Charge (e) Pounds of R-410A 9.5 9.4 continued on next page 24 RT-PRCO23-EN A TRANE General Data Table 2. General data - 5 tons - standard efficiency (continued) 5 Tons T/YSC060E1 T/YSC060E3,4,W Heating Performanceff) (Gas/Electric Only) Heating Input Low Heat Input (Btu) 60,000 60,000 Mid Heat Input (Btu) 80,000 80,000 High Heat Input (Btu) 130,000 130,000 Heating Output Low Heat Input (Btu) 48,000 48,000 Mid Heat Input (Btu) 65,000 64,000 High Heat Input (Btu) 104,000 104,000 AFUE%(9) Low Heat Input (Btu) 78 80 Mid Heat Input (Btu) 79 80 High Heat Input (Btu) 78 80 Steady State Efficiency% Low Heat Input (Btu) 80 80 Mid Heat Input (Btu) 81 80 High Heat Input (Btu) 80 80 No. Burners Low Heat Input (Btu) 2 2 Mid Heat Input (Btu) 2 2 High Heat Input (Btu) 3 3 No. Stages Low Heat Input (Btu) 1 1 Mid Heat Input (Btu) 1 1 High Heat Input (Btu) 1 1 Gas Supply Line Pressure Natural (minimum/maximum) 4.5/10.5 4.5/10.5 LP (minimum/maximum) 10.0/13.0 10.0/13.0 Gas Connection Pipe Size (in) Low Heat 1/2 1/2 Mid Heat 1/2 1/2 High Heat 1/2 1/2 (a) Cooling performance is rated at 95°F ambient, 80OF entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz). (b) EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. (c) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For additional information refer to Table 109, p. 134. (d) Optional 2" MERV 7 and MERV 13 filters also available. (e) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. (f) Heating performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Applicable to Gas/Electric units only. (g) AFUE is rated in accordance with DOE test procedures. RT-PRCO23-EN 25 TRAWE WF General Data Table 3. General data - 6-10 tons - standard efficiency 6 Tons 71/z Tons 81/z Tons 10 Tons T/YSC072E3,4,W T/YSC092E3,4,W T/YSC102E3,4,W T/YSC120E3,4,W Cooling Performance(a) Gross Cooling Capacity 75,000 94,000 102,000 118,000 EER(b) 11.2 11.2 11.2 10.6 Nominal cfm/ARI Rated cfm 2,400/2,100 3,000/2,625 3,400/2,975 4,000/3,500 ARI Net Cooling Capacity 71,200 89,300 96,600 110,300 Integrated Part Load Value(c) - 12.5 12.5 12.0 System Power (kW) 6.36 7.97 8.62 10.4 Compressor Number/Type 1/Scroll 2/Scroll 2/Scroll 2/Scroll Sound Outdoor Sound Rating (dB)(d) 89 87 86 86 Outdoor Coil Type Lanced Lanced Lanced Lanced Tube Size (in.) OD 0.3125 0.3125 0.3125 0.3125 Face Area (sq.ft.) 17 19.83 19.83 27.21 Rows/FPI 3/17 3/17 3/17 3/17 Indoor Coil Type Lanced Lanced Lanced Lanced Tube Size (in.) 0.3125 0.3125 0.3125 0.3125 Face Area (sq. ft.) 9.89 12.36 12.36 12.36 Rows/FPI 3/16 3/16 4/16 4/16 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Drain Connection Number/Size (in.) 13/4 NPT 13/4 NPT 13/4 NPT 13/4 NPT Outdoor Fan Type Propeller Propeller Propeller Propeller Number Used/Diameter (in.) 1/26 1/26 1/26 1/26 Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 cfm 6,037 6,610 6,610 7,057 Motor hp 0.7 0.75 0.75 0.75 Motor rpm 1,100 1,100 1,100 1,100 Indoor Fan Type (Standard) FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal Number Used/Diameter (in.) 1/12x12 1/15x15 1/15x15 1/15x15 Drive Type/Number Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable Motor hp (Standard/Oversized) 1.0/2.0 2.0/3.0 2.0/3.0 3.0/5.0 Motor Frame Size (Standard/Oversized) 56/56 56/56 56/56 56/56 Filters(e) Type Furnished Throwaway Throwaway Throwaway Throwaway Number Size Recommended (4) 16x25x2 (4) 20x25x2 (4) 20x25x2 (4) 20x25x2 Refrigerant Charge (f) Pounds of R-410A 10.5 7.12/6.62 8.37/7.56 12.25/7.03 continued on next page 26 RT-PRCO23-EN A TRANE General Data Table 3. General data - 6-10 tons - standard efficiency (continued) 6 Tons 71/2 Tons 81/2 Tons 10 Tons T/YSC072E3,4,W T/YSC092E3,4,W T/YSC102E3,4,W T/YSC120E3,4,W Heating Performance(9) (Gas/Electric Only) Heating Input Low Heat Input (Btu) 80,000 120,000 120,000 150,000/105,000 Mid Heat Input (Btu) 120,000 150,000/105,000 150,000/105,000 200,000/140,000 High Heat Input (Btu) 150,000/105,000 200,000/140,000 200,000/140,000 250,000/175,000 Heating Output Low Heat Input (Btu) 64,800 97,200 97,200 121,500/85,000 Mid Heat Input (Btu) 97,200 121,500/85,000 121,500/85,000 162,000/113,000 High Heat Input (Btu) 121,500/85,000 160,000/112,000 160,000/112,000 202,500/141,800 AFUE%(h) Low Heat Input (Btu) 81 81 81 81 Mid Heat Input (Btu) 81 81 81 81 High Heat Input (Btu) 81 81 81 81 Steady State Efficiency% Low Heat Input (Btu) 81 81 81 81 Mid Heat Input (Btu) 81 81 81 81 High Heat Input (Btu) 81 80 80 81 No. Burners Low Heat Input (Btu) 2 3 3 3 Mid Heat Input (Btu) 3 3 3 4 High Heat Input (Btu) 3 4 4 5 No. Stages Low Heat Input (Btu) 1 1 1 2 Mid Heat Input (Btu) 1 2 2 2 High Heat Input (Btu) 2 2 2 2 Gas Supply Line Pressure Natural (minimum/maximum) 4.5/14.0 4.5/14.0 4.5/14.0 4.5/14.0 LP (minimum/maximum) 10.0/14.0 10.0/14.0 10.0/14.0 10.0/14.0 Gas Connection Pipe Size (in) Low Heat 1/2 1/2 1/2 3/4 Mid Heat 1/2 3/4 3/4 3/4 High Heat 3/4 3/4 3/4 3/4 (a) Cooling performance is rated at 950F ambient, 80OF entering dry bulb, 670F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz). (b) EER is rated at ARI conditions and in accordance with DOE test procedures. (c) Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated 80°F ambient, 80OF entering dry bulb and 670F entering wet bulb at ARI rated cfm. (d) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For additional information refer to Table 109, p. 134. (e) Optional 2" MERV 7 and MERV 13 filters also available. (f) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. (g) Heating performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Applicable to Gas/Electric units only. (h)AFUE is rated in accordance with DOE test procedures. RT-PRCO23-EN 27 TRAWE WF General Data Table 4. General data - 3-4 tons - standard efficiency 3 Tons 4 Tons WSC036E1 WSC036E3,4,W WSC048EI WSC048E3,4,W Cooling Performance(a) Gross Cooling Capacity 37,650 38,030 49,040 50,130 SEER(b) 13.0 13.0 13.0 13.0 Nominal cfm/ARI Rated cfm 1,200/1,200 1,200/1,200 1,600/1,600 1,600/1,600 ARI Net Cooling Capacity 37,000 37,000 48,000 48,800 System Power (kW) 3.49 3.45 4.40 4.40 Heating Performance() High Temp. Btuh Rating 37,000 37,000 44,400 44,400 System Power kW/COP 3.31/3.30 3.21/3.40 3.91/3.30 3.86/3.40 Low Temp. Btuh Rating 21,200 20,700 25,000 24,900 System Power (kW)/COP 2.99/2.10 2.85/2.10 3.63/2.00 3.53/2.10 HSPF (Btu/Watts-hr) 8.00 8.00 7.80 7.80 Compressor Number/Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll Sound Outdoor Sound Rating (dB)(d) 81 80 82 82 Outdoor Coil Type Lanced Lanced Lanced Lanced Tube Size (in.) 0.3125 0.3125 0.3125 0.3125 Face Area (sq. ft.) 9.59 10.96 10.96 10.96 Rows/FPI 2/17 3/17 3/17 3/17 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Indoor Coil Type Lanced Lanced Lanced Lanced Tube Size (in.) 0.3125 0.3125 0.3125 0.3125 Face Area (sq. ft.) 6.68 6.68 7.71 7.71 Rows/FPI 3/16 3/16 4/16 4/16 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Drain Connection Number/Size (in.) 13/4 NPT 13/4 NPT 13/4 NPT 13/4 NPT Outdoor Fan Type Propeller Propeller Propeller Propeller Number Used/Diameter (in.) 1/22 1/22 1/22 1/22 Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 cfm 3,323 2,823 3,276 3,279 Number Motors/hp 0.25 0.25 0.40 0.40 Motor rpm 1,075 1,075 1,075 1,075 Indoor Fan Type (Standard) FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal Number Used/Diameter (in.) 1/11XI1 1/11X11 1/11xi1 1/11xi1 Drive Type/Number Speeds Direct/5 Belt/Variable Direct/5 Belt/Variable Motor hp 0.75 1.0 1.0 1.0 Motor Frame Size (Standard/Oversized) 48 56 48 56 continued on next page 28 RT-PRCO23-EN A TRANE General Data Table 4. General data - 3-4 tons - standard efficiency (continued) 3 Tons 14 Tons WSCO36E1 1 WSCO36E3,4,W I WSCO48E1 1 WSCO48E3,4,W Filters(e) Type Furnished Throwaway Throwaway Throwaway Throwaway Number Size Recommended (2) 20x30x1 (2) 20x30x1 (2) 20x30x1 (2) 20x30x1 Refrigerant Charge (f) Pounds of R-410A 5.6 7.3 8.8 9.4 (a) Cooling performance is rated at 95°F ambient, 80OF entering dry bulb, 670F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect offan motor heat. Units are suitable foroperation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz). (b) EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. (c) Heating performance is rated at 95°F ambient, 80OF entering dry bulb, 670F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect offan motor heat. Units are suitable foroperation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz). (d) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For additional information refer to Table 109, p. 134. (e) Optional 2" MERV 7 and MERV 13 filters also available. (f) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. RT-PRCO23-EN 29 TRAWE WF General Data Table 5. General data - 5 tons - standard efficiency 5 Tons WSC060E1 WSC060E3,4,W Cooling Performance(a) Gross Cooling Capacity 58,360 63,440 SEER(b) 13.0 13.0 Nominal cfm/ARI Rated cfm 2,000/2,000 2,000/2,000 ARI Net Cooling Capacity 57,000 62,000 System Power (kW) 5.06 5.13 Heating Performance() High Temp. Btuh Rating 58,500 58,500 System Power kW/COP 4.86/3.50 4.94/3.50 Low Temp. Btuh Rating 34,500 34,400 System Power kW/COP 4.46/2.30 4.44/2.30 HSPF (Btu/Watts-hr) 8.00 8.00 Compressor Number/Type 1/Scroll 1/Scroll Sound Outdoor Sound Rating (dB)(d) 87 87 Outdoor Coil Type Lanced Lanced Tube Size (in.) 0.3125 0.3125 Face Area (sq. ft.) 17.00 17.00 Rows/FPI 3/17 3/17 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Indoor Coil Type Lanced Lanced Tube Size (in.) 0.3125 0.3125 Face Area (sq. ft.) 9.27 9.27 Rows/FPI 3/16 3/16 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Drain Connection Number/Size (in.) 13/4 NPT 13/4 NPT Outdoor Fan Type Propeller Propeller Number Used/Diameter (in.) 1/26 1/26 Drive Type/No. Speeds Direct/1 Direct/1 cfm 5,145 5,138 Motor hp 0.40 0.40 Motor rpm 1,075 1,075 Indoor Fan Type (Standard) FC Centrifugal FC Centrifugal Number Used/Diameter (in.) 1/11X11 1/11x11 Drive Type/Number Speeds Direct/5 Belt/Variable Motor hp 1.00 1.00 Motor Frame Size 48 56 continued on next page 30 RT-PRCO23-EN A TRANE Table 5. General data - 5 tons - standard efficiency (continued) Filters(e) Type Furnished Number Size Recommended Refrigerant Charge(f) Pounds of R-410A General Data 5 Tons WSCO6OE1 WSCO6OE3,4,W Throwaway (4) 16x25x2 Throwaway (4) 16x25x2 10.0 10.6 (a) Cooling performance is rated at 950F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz). (b) EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. (c) Heating performance is rated at 950F ambient, 80OF entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz). (d) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For additional information refer to Table 109, p. 134. (e) Optional 2" MERV 7 and MERV 13 filters also available. (f) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. RT-PRCO23-EN 31 TRAWE WF General Data Table 6. General data - 3-4 tons - high efficiency 3 Tons 4 Tons T/YHC036E1 T/YHC036E3,4 T/YHC048E1 T/YHC048E3,4 Cooling Performance(a) Gross Cooling Capacity 38,490 38,490 48,930 49,930 SEER(b) 15.2 15.0 15.0 15.0 Nominal cfm/ARI Rated cfm 1,200/1,200 1,200/1,200 1,600/1,600 1,600/1,600 ARI Net Cooling Capacity 38,000 38,000 48,000 49,000 System Power (kW) 2.93 2.99 3.83 3.67 Compressor Number/Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll Sound Outdoor Sound Rating (dB)(c) 81 81 87 87 Outdoor Coil Type Lanced Lanced Lanced Lanced Tube Size (in.) OD 0.3125 0.3125 0.3125 0.3125 Face Area (sq. ft.) 10.96 10.96 17.00 17.00 Rows/FPI 3/17 3/17 3/17 3/17 Indoor Coil Type Lanced Lanced Lanced Lanced Tube Size (in.) 0.3125 0.3125 0.3125 0.3125 Face Area (sq. ft.) 7.71 7.71 9.27 9.27 Rows/FPI 3/16 3/16 3/16 3/16 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Drain Connection Number/Size (in.) 13/4 NPT 13/4 NPT 13/4 NPT 13/4 NPT Outdoor Fan Type Propeller Propeller Propeller Propeller Number Used/Diameter (in.) 1/22 1/22 1/26 1/26 Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 cfm 3,064 3,064 3,986 3,982 Motor hp 0.2 0.2 0.4 0.4 Motor rpm 1,075 1,075 1,075 1,075 Indoor Fan Type (Standard) FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal Number Used/Diameter (in.) 1/11XI1 1/11XI1 1/11X11 1/11X11 Drive Type/Number Speeds Direct/5 Direct/5 Direct/5 Direct/5 Number Motors 1 1 1 1 Motor hp (Standard/Oversized) 0.75 1.0 1.0 1.0 Motor Frame Size (Standard/Oversized) 48 48 48 48 Indoor Fan Type (Optional) - FC Centrifugal - FC Centrifugal Number Used/Diameter (in.) - 1/1Ix11 - 1/11XI1 Drive Type/Number Speeds - Belt/Variable - Belt/Variable Number Motors - 1 - 1 Motor hp (Standard/Oversized) - 1.0 - 1.0 Motor Frame Size (Standard/Oversized) - 56 - 56 Filters(d) Type Furnished Throwaway Throwaway Throwaway Throwaway Number Size Recommended (2) 20x30x1 (2) 20x30x1 (4) 16x25x2 (4) 16x25x2 Refrigerant Charge (e) Pounds of R-410A 7.9 7.9 11.0 11.0 continued on next page 32 RT-PRCO23-EN A TRANE General Data Table 6. General data - 3-4 tons - high efficiency (continued) 3 Tons 4 Tons T/YHC036E1 T/YHC036E3,4 T/YHC048E1 T/YHC048E3,4 Heating Performance(f) (Gas/Electric Only) Heating Input Low Heat Input (Btu) 60,000 60,000 60,000 60,000 Mid Heat Input (Btu) 80,000 80,000 80,000 80,000 High Heat Input (Btu) 120,000 120,000 120,000 120,000 Heating Output Low Heat Input (Btu) 48,000 48,000 49,000 48,000 Mid Heat Input (Btu) 65,000 64,000 64,000 64,000 High Heat Input (Btu) 96,000 96,000 96,000 96,000 AFUE%(9) Low Heat Input (Btu) 78 78 80 80 Mid Heat Input (Btu) 78 78 79 79 High Heat Input (Btu) 78 78 79 79 Steady State Efficiency% Low Heat Input (Btu) 80 80 81 81 Mid Heat Input (Btu) 81 80 80 80 High Heat Input (Btu) 80 80 80 81 No. Burners Low Heat Input (Btu) 2 2 2 2 Mid Heat Input (Btu) 2 2 2 2 High Heat Input (Btu) 3 3 3 3 No. Stages Low Heat Input (Btu) 1 1 1 1 Mid Heat Input (Btu) 1 1 1 1 High Heat Input (Btu) 1 1 1 1 Gas Supply Line Pressure Natural (minimum/maximum) 4.5/10.5 4.5/10.5 4.5/10.5 4.5/10.5 LP (minimum/maximum) 10.0/13.0 10.0/13.0 10.0/13.0 10.0/13.0 Gas Connection Pipe Size (in) Low Heat 1/2 1/2 1/2 1/2 Mid Heat 1/2 1/2 1/2 1/2 High Heat 1/2 1/2 1/2 1/2 (a) Cooling performance is rated at 950F ambient, 80OF entering dry bulb, 670F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz). (b) EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. (c) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For additional information refer to Table 109, p. 134. (d) Optional 2" MERV 7 and MERV 13 filters also available. (e) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. (f) Heating performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Applicable to Gas/Electric units only. (g) AFUE is rated in accordance with DOE test procedures. RT-PRCO23-EN 33 TRAWE WF General Data Table 7. General data - 5 tons - high efficiency 5 Tons T/YH060E1 T/YHC060E3,4 Cooling Performance(a) Gross Cooling Capacity 62,490 63,490 SEER(b) 14.8 15.0 Nominal cfm/ARI Rated cfm 2,000/2,000 2,000/2,000 ARI Net Cooling Capacity 61,000 62,000 System Power (kW) 4.75 4.83 Compressor Number/Type 1/Scroll 1/Scroll Sound Outdoor Sound Rating (dB)(0 87 87 Outdoor Coil Type Lanced Lanced Tube Size (in.) 0.3125 0.3125 Face Area (sq. ft.) 17.00 17.00 Rows/FPI 3/17 3/17 Indoor Coil Type Lanced Lanced Tube Size (in.) 0.3125 0.3125 Face Area (sq. ft.) 9.89 9.89 Rows/FPI 4/16 4/16 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Drain Connection Number/Size (in.) 13/4 NPT 13/4 NPT Outdoor Fan Type Propeller Propeller Number Used/Diameter (in.) 1/26 1/26 Drive Type/No. Speeds Direct/1 Direct/1 cfm 3,953 3,953 Number Motors/hp 0.40 0.40 Motor rpm 1,075 1,075 Indoor Fan Type (Standard) FC Centrifugal FC Centrifugal Number Used/Diameter (in.) 1/11XI1 1/1Ix1I Drive Type/Number Speeds Direct/5 Direct/5 Motor hp 1.0 1.0 Motor Frame Size 48 48 Indoor Fan Type (Optional) — FC Centrifugal Number Used/Diameter (in.) — 1/1Ix1I Drive Type/Number Speeds — Belt/Variable Motor hp — 1.0 Motor Frame Size — 56 Filters(d) Type Furnished Throwaway Throwaway Number Size Recommended (4) 16x25x2 (4) 16x25x2 Refrigerant Charge(e) Pounds of R-410A 12.5 12.5 continued on next page 34 RT-PRCO23-EN A TRANE General Data Table 7. General data - 5 tons - high efficiency (continued) 5 Tons T/YH060E1 T/YHC060E3,4 Heating Performanceff) (Gas/Electric Only) Heating Input Low Heat Input (Btu) 60,000 60,000 Mid Heat Input (Btu) 80,000 80,000 High Heat Input (Btu) 130,000 130,000 Heating Output Low Heat Input (Btu) 49,000 48,000 Mid Heat Input (Btu) 64,000 64,000 High Heat Input (Btu) 104,000 104,000 AFUE%(9) Low Heat Input (Btu) 80 80 Mid Heat Input (Btu) 79 79 High Heat Input (Btu) 80 80 Steady State Efficiency% Low Heat Input (Btu) 81 81 Mid Heat Input (Btu) 80 80 High Heat Input (Btu) 80 80 No. Burners Low Heat Input (Btu) 2 2 Mid Heat Input (Btu) 2 2 High Heat Input (Btu) 3 3 No. Stages Low Heat Input (Btu) 1 1 Mid Heat Input (Btu) 1 1 High Heat Input (Btu) 1 1 Gas Supply Line Pressure Natural (minimum/maximum) 4.5/10.5 4.5/10.5 LP (minimum/maximum) 10.0/13.0 10.0/13.0 Gas Connection Pipe Size (in) Low Heat 1/2 1/2 Mid Heat 1/2 1/2 High Heat 1/2 1/2 (a) Cooling performance is rated at 95°F ambient, 80OF entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz). (b) EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. (c) Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For additional information refer to Table 109, p. 134. (d) Optional 2" MERV 7 and MERV 13 filters also available. (e) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. (f) Heating performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Applicable to Gas/Electric units only. (g) AFUE is rated in accordance with DOE test procedures. RT-PRCO23-EN 35 0 TRINE" Performance Data Table 8. Gross cooling capacities 3 tons standard efficiency - single phase T/YSC036E1 j%muient temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1080 75 33.6 28.2 37.2 20.6 41.0 12.4 31.0 26.6 34.4 19.3 38.0 10.9 28.2 25.2 31.4 17.4 34.9 9.2 1080 80 34.6 34.5 37.7 26.6 41.7 19.7 32.2 32.2 34.9 25.2 38.8 17.6 29.8 29.8 31.9 23.5 35.6 16.2 1080 85 36.8 36.8 38.2 32.8 42.1 25.2 34.4 34.4 35.4 31.3 39.1 23.5 32.0 32.0 32.5 30.0 36.0 22.0 1080 90 39.1 39.1 39.2 39.1 42.4 30.9 36.8 36.8 36.7 36.7 39.5 29.4 34.3 34.3 34.2 34.2 36.4 27.9 1200 75 34.4 30.2 38.0 21.7 41.8 12.5 31.7 28.7 35.1 20.2 38.7 11.6 28.9 27.3 32.0 18.4 35.5 9.5 1200 80 35.8 35.8 38.5 28.2 42.6 20.0 33.4 33.4 35.6 26.9 39.5 18.6 30.9 30.9 32.6 25.1 36.2 16.9 1200 85 38.2 38.2 39.0 35.3 42.8 26.4 35.8 35.8 36.2 34.0 39.8 24.9 33.2 33.2 33.4 32.5 36.6 23.5 1200 90 40.6 40.6 40.6 40.6 43.2 33.1 38.2 38.2 38.1 38.1 40.2 31.5 35.6 35.6 35.5 35.5 37.1 29.9 1320 75 35.0 32.3 38.6 22.6 42.4 12.7 32.4 30.7 35.6 20.9 39.3 11.1 29.6 29.0 32.5 19.4 36.0 10.3 1320 80 37.0 37.0 39.1 30.3 43.2 20.9 34.5 34.5 36.2 28.5 40.0 19.3 31.8 31.8 33.2 26.8 36.7 17.7 1320 85 39.4 39.4 39.8 37.9 43.5 27.9 36.9 36.9 37.1 36.3 40.4 26.4 34.3 34.3 34.3 34.2 37.1 24.7 1320 90 41.9 41.9 41.9 41.9 43.9 35.0 39.4 39.4 39.4 39.4 40.8 33.6 36.7 36.7 36.6 36.6 37.6 32.2 1440 75 35.7 34.2 39.1 23.7 43.0 13.6 33.0 32.4 36.1 22.2 39.8 11.4 30.2 30.2 33.0 20.4 36.5 10.6 1440 80 38.0 38.0 39.7 31.6 43.7 21.7 35.4 35.4 36.7 30.1 40.5 20.4 32.7 32.7 33.7 28.8 37.1 18.4 1440 85 40.5 40.5 40.6 40.0 44.0 29.3 37.9 37.9 37.9 37.9 40.9 27.8 35.2 35.2 35.2 35.2 37.6 26.2 1440 90 43.1 43.1 43.1 43.1 44.5 37.2 40.5 40.5 40.4 40.4 41.5 36.1 37.7 37.7 37.7 37.7 38.3 34.8 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 25.3 SHC 23.7 MBh 28.3 SHC 15.8 MBh 31.6 SHC 8.3 1080 75 1080 80 27.1 27.1 28.8 21.8 32.3 14.6 1080 85 29.4 29.4 29.6 28.6 32.7 20.4 1080 90 31.6 26.0 31.6 25.5 31.6 28.8 31.6 16.7 33.1 32.1 26.3 8.5 1200 75 1200 80 28.2 28.2 29.4 23.5 32.8 15.6 1200 85 30.5 30.5 30.5 30.4 33.2 21.8 1200 90 32.8 26.7 32.8 26.7 32.8 29.3 32.8 17.8 33.8 32.6 28.5 8.7 1320 75 1320 80 29.1 29.1 29.9 25.4 33.2 16.4 1320 85 31.4 31.4 31.4 31.4 33.8 23.1 1320 90 33.8 27.4 33.8 27.4 33.8 29.7 33.8 18.6 34.3 32.9 31.1 8.9 1440 75 1440 80 29.9 29.9 30.4 27.3 33.6 16.7 1440 85 32.3 32.3 32.3 32.3 34.2 24.7 1440 90 34.7 34.7 34.7 34.7 35.0 33.5 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity 36 RT-PRCO23-EN A TRANE Performance Data Table 9. Gross cooling capacities 3 tons standard efficiency - three phase T/YSC036E,3,4,W Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1080 75 34.9 29.1 38.7 21.5 42.6 12.9 32.4 27.7 36.0 19.8 39.8 11.8 29.8 26.2 33.3 18.4 36.9 9.9 1080 80 35.6 35.6 39.0 27.6 43.2 19.3 33.5 33.5 36.4 26.1 40.3 18.2 31.2 31.2 33.6 24.7 37.4 16.7 1080 85 37.9 37.9 39.4 33.5 43.5 25.8 35.7 35.7 36.8 32.2 40.7 24.5 33.5 33.5 34.1 30.9 37.8 23.3 1080 90 40.1 40.1 40.1 40.1 43.7 31.8 38.0 38.0 37.9 37.9 41.0 30.5 35.7 35.7 35.6 35.6 38.1 29.1 1200 75 35.6 31.1 39.4 22.3 43.4 13.3 33.2 29.7 36.7 21.0 40.5 11.2 30.5 28.3 33.9 19.3 37.5 10.1 1200 80 36.9 36.9 39.8 29.2 43.9 19.6 34.7 34.7 37.2 27.8 41.1 18.7 32.4 32.4 34.4 26.3 38.1 17.9 1200 85 39.3 39.3 40.2 36.1 44.3 27.3 37.1 37.1 37.6 34.8 41.5 26.0 34.7 34.7 35.0 33.8 38.5 24.6 1200 90 41.7 41.7 41.6 41.6 44.5 33.9 39.4 39.4 39.4 39.4 41.7 32.6 37.0 37.0 37.0 37.0 38.8 31.2 1320 75 36.3 33.1 40.1 23.3 44.0 13.2 33.8 31.7 37.3 22.0 41.1 11.4 31.2 30.4 34.4 20.1 38.0 10.0 1320 80 38.1 38.1 40.5 30.9 44.6 21.0 35.8 35.8 37.8 29.4 41.7 20.1 33.4 33.4 34.9 28.1 38.6 17.9 1320 85 40.6 40.6 41.0 38.8 45.0 28.7 38.3 38.3 38.5 37.6 42.0 27.0 35.8 35.8 35.9 35.8 39.0 25.9 1320 90 43.0 43.0 43.0 43.0 45.2 36.0 40.7 40.7 40.6 40.6 42.4 34.8 38.2 38.2 38.1 38.1 39.4 33.3 1440 75 37.0 35.1 40.6 24.3 44.6 13.4 34.5 33.8 37.8 22.8 41.6 12.0 31.8 31.8 34.9 21.5 38.5 10.7 1440 80 39.1 39.1 41.1 32.6 45.2 22.3 36.8 36.8 38.3 31.1 42.2 21.2 34.3 34.3 35.4 29.8 39.1 19.6 1440 85 41.7 41.7 41.8 41.3 45.5 30.2 39.3 39.3 39.3 39.3 42.5 28.7 36.8 36.8 36.8 36.8 39.5 27.1 1440 90 44.2 44.2 44.2 44.2 45.8 38.1 41.8 41.8 41.7 41.7 43.0 36.7 39.2 39.2 39.2 39.2 39.9 35.6 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 27.0 SHC 24.8 MBh 30.3 SHC 16.9 MBh 33.7 SHC 8.6 1080 75 1080 80 28.7 28.7 30.7 23.2 34.2 15.4 1080 85 30.9 30.9 31.2 29.8 34.6 21.6 1080 90 33.1 27.7 33.1 27.0 33.1 30.8 33.1 18.0 34.9 34.3 27.5 8.7 1200 75 1200 80 29.8 29.8 31.3 24.8 34.8 15.9 1200 85 32.1 32.1 32.1 32.1 35.2 23.0 1200 90 34.4 28.4 34.4 28.4 34.3 31.3 34.3 18.7 35.6 34.7 29.8 8.6 1320 75 1320 80 30.7 30.7 31.8 26.5 35.3 17.4 1320 85 33.1 33.1 33.1 33.1 35.7 24.4 1320 90 35.5 29.1 35.5 29.1 35.5 31.7 35.5 19.8 36.1 35.1 32.0 9.2 1440 75 1440 80 31.6 31.6 32.3 28.4 35.7 18.3 1440 85 34.0 34.0 34.0 34.0 36.2 25.9 1440 90 36.4 36.4 36.4 36.4 36.7 34.6 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity RT-PRCO23-EN 37 M TRAME WF Performance Data Table 10. Gross cooling capacities 4 tons standard efficiency -single phase T/YSC048E1 Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1440 75 46.2 38.6 51.6 28.3 57.2 17.8 42.8 36.7 48.0 26.4 53.4 15.6 39.1 34.6 44.1 24.4 49.3 15.6 1440 80 46.9 46.9 51.9 36.5 57.6 26.2 44.0 44.0 48.3 34.6 53.9 24.3 40.8 40.8 44.4 32.6 49.7 22.0 1440 85 49.9 49.9 52.2 44.8 57.9 34.2 47.0 47.0 48.6 42.9 54.1 32.3 43.8 43.8 44.9 41.1 50.1 30.4 1440 90 53.0 53.0 52.9 52.9 58.2 42.3 50.0 50.0 49.9 49.9 54.4 40.5 46.8 46.8 46.7 46.7 50.3 38.7 1600 75 47.2 41.3 52.6 29.7 58.3 18.0 43.8 39.3 48.9 27.8 54.3 18.1 40.0 37.4 44.9 25.8 50.2 14.1 1600 80 48.7 48.7 52.9 38.8 58.8 27.2 45.7 45.7 49.2 36.9 54.8 25.4 42.4 42.4 45.3 35.0 50.6 23.5 1600 85 51.9 51.9 53.3 48.2 59.0 36.2 48.8 48.8 49.7 46.4 55.1 34.4 45.5 45.5 45.9 44.4 51.0 32.5 1600 90 55.0 55.0 55.0 55.0 59.2 45.3 51.9 51.9 51.9 51.9 55.4 43.5 48.6 48.6 48.6 48.6 51.4 41.8 1760 75 48.2 44.0 53.5 31.1 59.1 18.2 44.6 42.0 49.7 29.2 55.1 16.2 40.8 40.0 45.6 27.1 50.8 14.8 1760 80 50.3 50.3 53.8 41.2 59.6 28.3 47.1 47.1 50.1 39.3 55.6 26.5 43.8 43.8 46.0 37.3 51.4 24.6 1760 85 53.6 53.6 54.2 51.5 59.9 38.3 50.4 50.4 50.7 49.7 56.0 36.4 47.0 47.0 46.9 46.9 51.7 34.6 1760 90 56.8 56.8 56.8 56.8 60.1 48.3 53.7 53.7 53.6 53.6 56.3 46.5 50.2 50.2 50.2 50.2 52.1 44.7 1920 75 48.9 46.6 54.2 32.5 59.9 20.1 45.3 44.7 50.3 30.6 55.7 17.1 41.7 41.7 46.2 28.7 51.4 14.4 1920 80 51.7 51.7 54.5 43.5 60.4 29.4 48.5 48.5 50.8 41.7 56.3 27.7 45.0 45.0 46.7 39.7 52.0 25.8 1920 85 55.0 55.0 55.3 54.9 60.6 40.3 51.8 51.8 51.8 51.8 56.6 38.5 48.3 48.3 48.3 48.3 52.4 36.6 1920 90 58.4 58.4 58.3 58.3 60.9 51.3 55.2 55.2 55.1 55.1 57.0 49.6 51.7 51.7 51.6 51.6 52.9 47.8 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 35.3 SHC 32.6 MBh 40.0 SHC 22.3 MBh 44.9 SHC 11.9 1440 75 1440 80 37.4 37.4 40.3 30.6 45.5 20.3 1440 85 40.4 40.4 40.9 39.1 45.8 28.5 1440 90 43.3 36.1 43.3 35.2 43.3 40.7 43.3 23.7 46.2 45.6 36.7 12.5 1600 75 1600 80 38.9 38.9 41.2 33.0 46.3 21.4 1600 85 41.9 41.9 42.0 42.0 46.6 30.6 1600 90 45.0 37.0 45.0 37.0 45.0 41.3 45.0 25.2 47.0 46.3 39.8 12.6 1760 75 1760 80 40.2 40.2 41.8 35.3 46.8 22.6 1760 85 43.4 43.4 43.3 43.3 47.2 32.6 1760 90 46.5 38.1 46.5 38.1 46.4 41.8 46.4 26.5 47.7 46.8 42.8 12.4 1920 75 1920 80 41.3 41.3 42.4 37.7 47.4 23.7 1920 85 44.6 44.6 44.6 44.6 47.9 34.7 1920 90 47.8 47.8 47.8 47.8 48.3 45.8 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity 38 RT-PRCO23-EN A TRANE Performance Data Table 11. Gross cooling capacities 4 tons standard efficiency -three phase T/YSC048E,3,4,W Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1440 75 46.2 38.9 51.7 28.6 57.3 17.6 42.8 37.0 48.0 26.6 53.5 16.0 39.2 35.0 44.1 24.5 49.3 14.0 1440 80 47.2 47.2 52.0 36.8 57.9 25.5 44.2 44.2 48.4 34.9 54.0 24.4 41.1 41.1 44.6 33.1 49.9 22.8 1440 85 50.4 50.4 52.5 45.3 58.3 34.5 47.4 47.4 48.9 43.4 54.4 32.7 44.2 44.2 45.2 41.5 50.3 31.0 1440 90 53.5 53.5 53.5 53.5 58.7 42.8 50.5 50.5 50.4 50.4 54.8 40.9 47.3 47.3 47.2 47.2 50.8 39.2 1600 75 47.3 41.6 52.7 29.9 58.3 17.6 43.8 39.7 48.9 27.9 54.4 16.2 40.1 37.6 44.9 25.9 50.1 14.1 1600 80 49.1 49.1 53.1 39.2 59.0 27.8 46.0 46.0 49.4 37.3 55.0 25.6 42.7 42.7 45.5 35.5 50.8 23.8 1600 85 52.3 52.3 53.7 48.6 59.4 36.5 49.3 49.3 50.0 46.6 55.4 35.0 46.0 46.0 46.2 44.9 51.2 32.9 1600 90 55.6 55.6 55.6 55.6 59.8 45.8 52.5 52.5 52.4 52.4 55.9 44.1 49.2 49.2 49.1 49.1 51.8 42.3 1760 75 48.3 44.3 53.5 31.3 59.3 18.4 44.7 42.3 49.7 29.3 55.2 16.2 41.0 40.5 45.6 27.7 50.8 14.5 1760 80 50.7 50.7 54.1 41.6 59.9 28.9 47.6 47.6 50.3 39.7 55.9 27.0 44.1 44.1 46.3 37.8 51.5 24.7 1760 85 54.1 54.1 54.7 51.9 60.3 38.6 50.9 50.9 51.1 50.2 56.3 36.8 47.5 47.5 47.4 47.4 52.0 34.8 1760 90 57.5 57.5 57.5 57.5 60.8 48.9 54.3 54.3 54.3 54.3 56.9 47.2 50.8 50.8 50.7 50.7 52.6 45.2 1920 75 49.1 46.9 54.3 32.9 59.9 18.3 45.5 45.0 50.4 30.8 55.8 16.6 42.0 42.0 46.2 29.0 51.3 15.3 1920 80 52.1 52.1 54.8 44.1 60.7 30.0 48.9 48.9 51.1 42.1 56.5 27.3 45.4 45.4 46.9 40.1 52.1 26.2 1920 85 55.6 55.6 55.7 55.3 61.1 40.8 52.3 52.3 52.3 52.3 57.0 38.9 48.8 48.8 48.8 48.8 52.7 37.1 1920 90 59.2 59.2 59.2 59.2 61.6 52.0 55.8 55.8 55.8 55.8 57.6 50.1 52.3 52.3 52.2 52.2 53.4 48.1 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 35.3 SHC 32.9 MBh 39.9 SHC 22.7 MBh 44.8 SHC 11.5 1440 75 1440 80 37.7 37.7 40.5 31.1 45.5 20.6 1440 85 40.8 40.8 41.0 39.5 46.0 28.8 1440 90 43.8 36.2 43.8 35.7 43.7 40.7 43.7 23.7 46.4 45.5 37.2 11.5 1600 75 1600 80 39.2 39.2 41.3 33.4 46.3 21.7 1600 85 42.4 42.4 42.3 42.3 46.8 30.9 1600 90 45.5 37.2 45.5 37.2 45.5 41.3 45.5 25.7 47.4 46.2 40.5 12.5 1760 75 1760 80 40.5 40.5 42.0 35.8 46.9 23.0 1760 85 43.8 43.8 43.8 43.8 47.5 32.9 1760 90 47.0 38.3 47.0 38.3 46.9 41.8 46.9 26.9 48.1 46.8 43.4 13.0 1920 75 1920 80 41.7 41.7 42.6 38.1 47.5 24.1 1920 85 45.0 45.0 44.9 44.9 48.0 35.0 1920 90 48.4 48.4 48.4 48.4 48.8 46.4 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity RT-PRCO23-EN 39 M TRAME WF Performance Data Table 12. Gross cooling capacities 5 tons standard efficiency - single phase T/YSC060E1 Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1800 75 56.4 48.2 62.4 34.4 69.0 21.3 52.6 46.3 58.4 32.8 64.7 18.5 48.5 44.2 54.1 30.8 60.1 17.6 1800 80 57.5 57.5 62.8 45.1 69.4 31.1 54.3 54.3 58.9 43.2 65.2 29.5 50.7 50.7 54.5 41.2 60.5 27.6 1800 85 61.1 61.1 63.3 55.7 69.8 41.7 57.8 57.8 59.3 53.8 65.5 39.9 54.2 54.2 55.1 51.9 60.9 38.0 1800 90 64.7 64.7 64.6 64.6 70.1 52.1 61.3 61.3 61.2 61.2 65.9 50.3 57.6 57.6 57.6 57.6 61.3 48.4 2000 75 57.5 51.4 63.6 36.1 70.1 21.4 53.7 49.5 59.5 34.1 65.8 19.9 49.6 47.6 55.0 32.2 61.1 17.4 2000 80 59.5 59.5 64.0 47.9 70.6 32.6 56.1 56.1 59.9 46.0 66.3 30.7 52.5 52.5 55.5 44.1 61.6 28.8 2000 85 63.2 63.2 64.6 59.7 71.0 44.1 59.8 59.8 60.5 58.0 66.6 42.5 56.1 56.1 56.4 56.0 61.9 40.4 2000 90 67.0 67.0 66.9 66.9 71.4 55.8 63.5 63.5 63.5 63.5 67.0 53.9 59.7 59.7 59.6 59.6 62.3 52.1 2200 75 58.6 54.7 64.6 37.8 71.2 22.1 54.7 52.8 60.3 35.9 66.7 18.5 50.6 50.3 55.8 34.0 61.9 17.6 2200 80 61.3 61.3 65.0 50.7 71.6 33.9 57.8 57.8 60.8 48.9 67.2 32.1 54.0 54.0 56.3 47.0 62.3 30.2 2200 85 65.1 65.1 65.8 63.9 72.0 46.6 61.6 61.6 61.8 61.6 67.5 44.8 57.8 57.8 57.7 57.7 62.7 42.9 2200 90 69.0 69.0 68.9 68.9 72.4 59.3 65.4 65.4 65.4 65.4 68.0 57.7 61.4 61.4 61.4 61.4 63.2 55.8 2400 75 59.5 57.9 65.4 39.5 72.1 20.4 55.6 55.4 61.1 37.6 67.4 19.7 51.6 51.6 56.5 35.6 62.5 17.6 2400 80 62.8 62.8 65.9 53.6 72.5 34.9 59.2 59.2 61.6 51.8 68.0 33.5 55.3 55.3 57.0 49.8 63.1 31.5 2400 85 66.8 66.8 66.9 66.8 72.9 49.2 63.2 63.2 63.2 63.2 68.3 47.3 59.2 59.2 59.1 59.1 63.4 45.4 2400 90 70.9 70.9 70.7 70.7 73.3 63.1 67.0 67.0 67.0 67.0 68.8 61.4 63.0 63.0 62.9 62.9 64.0 59.7 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 44.2 SHC 42.1 MBh 49.4 SHC 28.4 MBh 55.1 SHC 15.2 1800 75 1800 80 46.9 46.9 49.8 39.1 55.5 25.5 1800 85 50.2 50.2 50.5 49.9 55.8 35.9 1800 90 53.5 45.2 53.5 45.0 53.5 50.2 53.5 30.2 56.2 55.9 46.5 15.2 2000 75 2000 80 48.5 48.5 50.7 42.0 56.3 26.9 2000 85 51.9 51.9 51.9 51.9 56.7 38.5 2000 90 55.4 46.3 55.4 46.3 55.4 50.9 55.4 31.9 57.2 56.6 50.2 15.6 2200 75 2200 80 49.8 49.8 51.4 44.9 57.0 28.2 2200 85 53.4 53.4 53.4 53.4 57.4 41.0 2200 90 57.0 47.5 57.0 47.5 57.0 51.5 57.0 33.6 58.0 57.2 54.0 15.7 2400 75 2400 80 51.0 51.0 52.1 47.9 57.6 29.6 G�VV UJ JY./ JT./ Jam./ JT./ JV.V TJ.V 2400 90 158.4 58.4 58.4 58.4 58.8 57.7 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity 40 RT-PRCO23-EN A TRANE Performance Data Table 13. Gross cooling capacities 5 tons standard efficiency -three phase T/YSCO6OE3,4,W Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1800 75 58.8 50.1 65.0 36.7 71.7 22.6 54.7 47.9 60.6 35.4 67.1 20.8 50.3 45.5 56.1 32.4 62.3 19.5 1800 80 59.9 59.9 65.4 47.0 72.1 33.4 56.3 56.3 61.1 44.9 67.5 31.4 52.6 52.6 56.6 42.9 62.7 29.6 1800 85 63.5 63.5 65.9 57.7 72.5 43.9 59.9 59.9 61.6 55.6 67.9 41.6 56.1 56.1 57.0 53.3 63.0 39.8 1800 90 67.1 67.1 67.1 67.1 72.9 54.1 63.5 63.5 63.5 63.5 68.2 52.3 59.6 59.6 59.5 59.5 63.4 50.3 2000 75 60.0 53.4 66.2 38.7 72.9 24.5 55.8 51.1 61.8 35.8 68.2 22.4 51.5 49.0 57.1 34.3 63.3 20.3 2000 80 62.0 62.0 66.7 50.2 73.4 35.3 58.4 58.4 62.3 48.1 68.6 33.6 54.5 54.5 57.6 46.0 63.6 30.5 2000 85 65.8 65.8 67.2 61.8 73.8 46.5 62.1 62.1 62.8 59.8 69.1 44.7 58.1 58.1 58.1 57.5 64.1 42.6 2000 90 69.6 69.6 69.6 69.6 74.1 58.0 65.8 65.8 65.8 65.8 69.3 56.1 61.7 61.7 61.7 61.7 64.5 54.2 2200 75 61.0 56.8 67.3 41.3 74.0 24.2 56.8 54.4 62.7 38.2 69.2 22.2 52.4 52.1 58.0 36.2 64.1 21.3 2200 80 63.9 63.9 67.7 53.1 74.5 38.1 60.1 60.1 63.2 51.0 69.6 35.1 56.1 56.1 58.5 49.0 64.6 32.2 2200 85 68.0 67.4 68.4 66.0 74.8 49.8 64.0 64.0 64.0 63.7 70.0 47.3 59.9 59.9 59.7 59.7 64.9 45.4 2200 90 71.7 71.7 71.8 71.8 75.2 62.0 67.8 67.8 67.8 67.8 70.4 60.1 63.6 63.6 63.5 63.5 65.2 57.8 2400 75 62.0 60.1 68.1 42.2 74.9 24.2 57.8 57.6 63.5 40.0 70.0 22.2 53.7 53.7 58.7 38.0 64.9 20.6 2400 80 65.6 65.6 68.6 56.1 75.2 39.4 61.7 61.7 64.0 54.1 70.5 36.4 57.6 57.6 59.2 51.9 65.3 34.4 2400 85 69.6 69.6 69.6 69.5 75.7 51.8 65.7 65.7 65.6 65.6 70.9 50.1 61.4 61.4 61.4 61.4 65.7 47.9 2400 90 73.6 73.6 73.5 73.5 76.2 65.7 69.6 69.6 69.5 69.5 71.2 63.6 65.2 65.2 65.2 65.2 66.1 61.5 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 45.8 SHC 43.3 MBh 51.2 SHC 30.4 MBh 57.1 SHC 18.0 1800 75 1800 80 48.6 48.6 51.7 40.7 57.4 27.8 1800 85 52.0 52.0 52.2 51.2 57.8 37.7 1800 90 55.4 46.9 55.4 46.7 55.3 52.1 55.3 32.2 58.2 58.0 48.2 16.9 2000 75 2000 80 50.3 50.3 52.6 43.7 58.3 29.6 2000 85 53.8 53.8 53.8 53.8 58.7 40.5 2000 90 57.3 48.2 57.3 48.2 57.3 52.9 57.3 34.0 59.1 58.7 52.0 17.6 2200 75 2200 80 51.8 51.8 53.4 46.7 59.0 30.4 2200 85 55.4 55.4 55.4 55.4 59.4 43.1 2200 90 59.0 49.3 59.0 49.3 59.0 53.5 59.0 35.7 59.9 59.3 55.7 17.7 2400 75 2400 80 53.1 53.1 54.0 49.5 59.7 32.2 2400 85 56.8 56.8 56.8 56.8 60.1 45.8 2400 90 60.5 60.5 60.5 60.5 60.7 59.5 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity RT-PRCO23-EN 41 M TRAME WF Performance Data Table 14. Gross cooling capacities 6 tons standard efficiency - three phase T/YSC072E3,4,W Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1920 75 68.5 52.9 75.2 37.7 82.4 22.5 64.4 50.7 70.8 35.5 77.6 20.2 60.0 48.2 66.1 33.2 72.6 17.9 1920 80 69.8 64.6 76.2 49.2 83.4 33.8 65.8 62.6 71.8 46.9 78.8 31.4 61.5 59.9 67.1 44.3 73.7 29.2 1920 85 72.2 72.2 77.2 60.4 84.4 44.5 68.5 68.5 72.8 58.1 79.7 42.5 64.7 64.7 68.1 55.9 74.7 40.4 1920 90 76.4 76.4 78.5 72.0 85.4 56.0 72.7 72.7 74.2 70.1 80.6 53.8 68.8 68.8 69.5 67.6 75.6 51.6 2160 75 70.3 56.6 77.0 39.5 84.2 22.3 66.1 54.3 72.4 37.4 79.2 20.1 61.7 52.1 67.6 35.1 74.0 18.0 2160 80 71.9 69.7 78.1 51.9 85.3 35.1 67.7 66.9 73.5 49.8 80.4 32.4 63.3 63.3 68.7 47.7 75.3 30.5 2160 85 75.3 75.3 79.2 65.1 90.8 55.7 71.5 71.5 74.7 62.9 85.5 54.0 67.4 67.4 69.9 60.6 80.0 51.8 2160 90 79.8 79.8 80.9 78.2 87.4 59.9 75.8 75.8 76.4 75.5 82.5 57.7 71.7 71.7 71.8 71.7 77.3 55.9 2400 75 72.0 60.4 78.5 41.3 85.6 22.5 67.6 58.1 73.8 39.2 80.6 20.4 63.0 55.7 68.9 36.0 75.2 18.2 2400 80 73.8 73.5 79.6 55.2 87.0 36.1 69.6 69.6 75.0 53.2 81.9 33.6 65.4 65.4 70.1 51.0 76.6 32.2 2400 85 78.0 78.0 81.0 69.7 88.1 50.4 74.0 74.0 76.4 67.6 83.1 48.6 69.8 69.8 71.5 65.4 77.8 45.9 2400 90 82.6 82.6 82.9 82.6 89.2 64.1 78.6 78.6 78.6 78.6 84.2 62.0 74.3 74.3 74.2 74.2 78.8 59.7 2640 75 73.4 64.0 79.8 42.1 86.9 22.5 68.9 61.7 75.0 40.0 81.6 19.9 64.3 59.4 70.0 37.6 76.1 18.0 2640 80 75.6 75.6 81.1 58.6 88.3 37.8 71.6 71.6 76.3 56.4 83.3 35.9 67.3 67.3 71.2 54.2 77.7 32.9 2640 85 80.4 80.4 82.7 74.5 89.6 52.9 76.3 76.3 77.9 72.3 84.4 50.4 71.9 71.9 73.0 70.1 79.0 48.9 2640 90 85.2 85.2 85.2 85.2 90.7 68.2 81.0 81.0 80.9 80.9 85.6 66.1 76.5 76.5 76.4 76.4 80.1 64.0 2880 75 74.6 67.7 81.0 44.7 88.0 22.9 70.1 65.4 76.1 42.1 82.5 20.0 65.4 62.8 70.9 40.0 76.8 18.0 2880 80 77.6 77.6 82.3 61.9 89.5 39.3 73.4 73.4 77.4 59.7 84.2 37.7 69.0 69.0 72.3 57.5 78.7 34.2 2880 85 82.5 82.5 84.1 79.1 90.8 55.7 78.2 78.2 79.3 76.7 85.5 54.0 73.7 73.7 74.2 73.3 80.0 51.8 2880 90 87.5 87.5 87.4 87.4 92.1 72.4 83.1 83.1 83.1 83.1 86.8 70.3 78.4 78.4 78.4 78.4 81.3 68.3 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 55.4 SHC 45.9 MBh 61.1 SHC 31.2 MBh 67.1 SHC 15.6 1920 75 1920 80 56.8 56.6 62.1 42.2 68.3 26.9 1920 85 60.5 60.5 63.1 53.6 69.3 38.3 1920 90 64.5 56.8 64.5 49.6 64.6 62.4 64.4 32.3 70.2 68.3 49.3 15.4 2160 75 2160 80 59.0 59.0 63.5 45.4 69.7 28.3 2160 85 63.0 63.0 64.8 58.4 74.0 48.9 2160 90 67.2 58.1 67.2 53.4 67.1 63.6 67.1 34.4 71.8 69.2 53.5 14.9 2400 75 2400 80 61.0 61.0 64.7 48.6 70.9 29.4 2400 85 65.3 65.3 66.4 63.3 72.0 43.8 2400 90 69.5 59.3 69.5 56.9 69.5 64.6 69.5 35.8 73.1 70.0 57.7 15.1 2640 75 2640 80 62.7 62.7 65.8 51.9 71.8 30.8 2640 85 67.1 67.1 67.6 66.8 73.1 46.3 2640 90 71.6 71.6 71.5 71.5 74.3 61.9 Notes: 60.3 59.5 65.4 37.5 70.6 14.1 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET 2880 75 cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate 2880 80 64.3 64.3 66.8 55.2 72.8 32.7 airflow table notes. 2. MBh = Total Gross Capacity 2880 85 68.8 68.8 68.9 68.8 74.0 48.9 3. SHC = Sensible Heat Capacity 2880 90 73.3 73.3 73.3 73.3 75.4 66.4 42 RT-PRCO23-EN TRANE Performance Data Table 15. Gross cooling capacities 71/2 tons standard efficiency - three phase T/YSCO92E3,4,W Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 2400 75 86.8 68.4 95.5 50.1 104.8 31.2 81.3 65.4 89.5 47.1 98.4 28.5 75.5 62.3 83.3 44.2 91.7 25.8 2400 80 88.1 83.1 96.2 64.0 105.6 45.3 82.6 80.0 90.2 60.9 99.2 42.7 77.1 76.1 84.0 57.9 92.5 39.7 2400 85 91.5 91.5 96.9 77.7 106.1 58.8 86.6 86.6 91.0 74.8 99.7 56.1 81.5 81.5 84.8 71.8 93.0 53.1 2400 90 96.4 96.4 98.0 92.3 106.7 72.5 91.4 91.4 92.3 89.3 100.3 69.6 86.2 86.2 86.4 85.4 93.5 66.7 2700 75 89.0 73.2 97.6 52.6 107.0 31.5 83.4 70.2 91.5 49.6 100.4 28.9 77.4 67.1 85.1 46.4 93.5 26.2 2700 80 90.6 88.9 98.4 68.0 107.8 47.4 85.3 84.9 92.3 65.0 101.2 44.3 79.8 79.8 85.8 62.0 94.2 41.8 2700 85 95.3 95.3 99.3 83.6 113.3 73.0 90.2 90.2 93.2 80.8 106.2 70.2 84.8 84.8 86.8 78.1 98.7 67.3 2700 90 100.5 100.5 100.9 99.1 109.0 77.6 95.2 95.2 95.4 95.1 102.4 74.7 89.6 89.6 89.6 89.6 95.4 71.9 3000 75 90.9 78.0 99.5 54.7 108.9 31.7 85.1 75.1 93.2 52.1 102.1 29.0 79.1 72.2 86.6 48.8 95.1 26.5 3000 80 93.3 93.2 100.2 72.0 109.6 49.0 88.0 88.0 94.0 69.1 102.9 46.5 82.5 82.5 87.4 66.1 95.8 43.4 3000 85 98.6 98.6 101.3 89.8 110.3 67.0 93.2 93.2 95.1 87.1 103.4 62.8 87.6 87.6 88.7 84.2 96.3 60.1 3000 90 104.0 104.0 104.0 103.9 110.9 82.8 98.5 98.5 98.4 98.4 104.1 80.0 92.6 92.6 92.6 92.6 97.0 77.1 3300 75 92.6 82.8 101.0 57.7 110.4 32.2 86.8 80.1 94.6 54.3 103.5 29.5 80.6 77.0 87.8 51.3 96.3 26.9 3300 80 95.8 95.8 101.9 76.2 111.3 51.0 90.5 90.5 95.4 73.1 104.3 48.1 84.8 84.8 88.7 70.3 97.0 44.8 3300 85 101.4 101.4 103.2 96.1 111.9 69.5 95.9 95.9 97.0 93.1 104.9 66.6 90.0 90.0 90.4 89.0 97.6 63.7 3300 90 107.0 107.0 106.9 106.9 112.6 88.2 101.3 101.3 101.2 101.2 105.6 85.4 95.2 95.2 95.1 95.1 98.4 82.6 3600 75 94.2 87.9 102.3 59.7 111.8 32.6 88.2 84.6 95.8 56.8 104.8 30.1 81.9 80.5 88.9 53.8 97.3 27.4 3600 80 98.2 98.2 103.3 80.4 112.7 53.0 92.7 92.7 96.7 77.5 105.5 50.0 86.8 86.8 89.9 74.6 98.1 47.1 3600 85 104.0 104.0 104.9 101.6 113.3 73.0 98.2 98.2 98.6 97.4 106.2 70.2 92.2 92.2 92.2 92.1 98.7 67.3 3600 90 109.7 109.7 109.6 109.6 114.1 93.6 103.8 103.8 103.7 103.7 107.0 91.0 97.5 97.5 97.4 97.4 99.7 88.6 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 69.4 SHC 59.1 MBh 76.8 SHC 41.2 MBh 84.7 SHC 23.0 2400 75 2400 80 71.5 71.4 77.4 54.8 85.4 36.8 2400 85 76.0 76.0 78.2 68.9 85.9 50.2 2400 90 80.5 71.2 80.5 64.3 80.4 78.4 80.4 43.4 86.4 86.3 63.7 23.2 2700 75 2700 80 74.2 74.2 79.0 58.9 87.0 38.5 2700 85 79.0 79.0 80.2 75.3 90.9 64.4 2700 90 83.6 72.8 83.6 69.1 83.6 79.7 83.6 45.9 88.0 87.6 68.8 23.4 3000 75 3000 80 76.7 76.7 80.5 63.1 88.3 41.0 3000 85 81.5 81.5 81.9 80.3 88.8 57.2 3000 90 86.4 74.1 86.4 72.8 86.3 80.7 86.3 48.2 89.4 88.6 74.3 23.5 3300 75 3300 80 78.7 78.7 81.6 67.3 89.4 42.3 3300 85 83.7 83.7 83.8 83.8 89.9 60.7 3300 90 88.7 75.5 88.7 75.4 88.6 81.7 88.6 50.6 90.7 89.5 80.2 23.6 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET 3600 75 cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to 3600 80 80.6 80.6 82.7 71.8 90.3 44.6 appropriate airflow table notes. 2. MBh = Total Gross Capacity 3600 85 85.7 85.7 85.6 85.6 90.9 64.4 3. SHC = Sensible Heat Capacity 3600 90 90.7 90.7 90.7 90.7 92.0 86.1 RT-PRCO23-EN 43 M TRAME WF Performance Data Table 16. Gross cooling capacities 81/2 tons standard efficiency - three phase T/YSC102E3,4,W Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 2720 75 93.9 74.9 103.6 55.0 113.9 34.3 88.1 71.6 97.4 52.1 107.2 33.2 82.1 68.2 91.0 49.0 100.4 28.2 2720 80 94.8 90.5 104.2 70.3 114.7 50.3 89.2 87.2 98.0 67.2 108.1 47.3 83.6 83.0 91.6 63.9 101.1 43.8 2720 85 99.1 99.1 104.8 85.6 115.2 65.1 94.0 94.0 98.7 82.4 108.6 62.1 88.6 88.6 92.3 79.1 101.8 59.0 2720 90 104.5 104.5 105.7 100.9 115.7 80.2 99.3 99.3 99.8 97.7 109.1 77.1 93.8 93.8 93.9 93.4 102.2 74.0 3060 75 96.2 80.3 105.9 58.0 116.2 35.2 90.3 77.1 99.6 54.8 109.3 32.1 84.1 73.6 92.9 51.8 102.2 28.5 3060 80 97.7 97.1 106.6 75.0 117.1 52.6 92.5 92.5 100.2 71.9 110.3 49.5 86.8 86.8 93.6 68.6 103.0 46.5 3060 85 103.4 103.4 107.3 92.2 122.8 81.7 97.8 97.8 101.0 89.0 115.6 79.3 92.5 92.5 94.4 85.7 108.0 75.6 3060 90 109.1 109.1 109.1 108.6 118.1 86.3 103.5 103.5 103.4 103.4 111.4 83.2 97.8 97.8 97.7 97.7 104.3 80.1 3400 75 98.2 85.5 107.8 61.0 118.0 35.5 92.1 82.3 101.4 57.8 110.9 30.3 85.8 79.0 94.5 55.6 103.7 29.0 3400 80 101.1 101.1 108.6 79.9 119.1 55.9 95.6 95.6 102.1 76.7 112.1 52.4 89.9 89.9 95.3 73.3 104.7 48.6 3400 85 107.1 107.1 109.4 98.7 119.6 73.3 101.4 101.4 103.1 95.7 112.7 70.9 95.5 95.5 96.4 92.6 105.4 67.5 3400 90 112.9 112.9 112.8 112.8 120.2 92.2 107.3 107.3 107.2 107.2 113.3 89.3 101.2 101.2 101.2 101.2 106.0 86.1 3740 75 99.9 90.9 109.5 64.0 119.6 35.5 93.8 87.7 102.8 60.6 112.3 31.2 87.4 84.3 95.8 57.2 104.8 27.7 3740 80 104.0 104.0 110.3 84.6 120.5 57.0 98.3 98.3 103.6 81.3 113.5 54.3 92.5 92.5 96.7 77.9 106.2 50.5 3740 85 110.1 110.1 111.4 105.7 121.3 77.8 104.3 104.3 104.9 102.2 114.2 74.6 98.3 98.3 98.5 97.9 106.8 71.7 3740 90 116.3 116.3 116.3 116.3 122.0 98.4 110.4 110.4 110.3 110.3 114.9 95.2 103.9 103.9 104.1 104.1 107.5 92.1 4080 75 101.4 96.3 110.8 65.2 120.8 34.1 95.3 92.8 104.0 63.2 113.3 33.1 88.9 88.3 96.9 60.2 105.8 30.2 4080 80 106.5 106.5 111.8 89.3 122.1 59.4 100.7 100.7 105.0 86.0 114.8 56.3 94.7 94.7 98.0 82.6 107.2 53.2 4080 85 112.9 112.9 113.3 111.7 122.8 81.7 107.0 107.0 107.2 107.1 115.6 79.3 100.8 100.8 100.7 100.7 108.0 75.6 4080 90 119.3 119.3 119.4 119.4 123.6 104.3 113.2 113.2 113.1 113.1 116.3 101.2 106.8 106.8 106.7 106.7 108.9 98.3 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 75.8 SHC 64.8 MBh 84.2 SHC 45.4 MBh 93.0 SHC 25.4 2720 75 2720 80 77.8 77.8 84.9 60.5 93.9 40.9 2720 85 82.9 82.9 85.5 75.6 94.4 55.7 2720 90 88.0 77.6 88.0 70.2 87.9 85.9 87.9 48.2 94.9 94.7 70.9 24.9 3060 75 3060 80 81.1 81.1 86.7 65.3 95.6 43.0 3060 85 86.4 86.4 87.6 82.6 100.1 72.6 3060 90 91.7 78.7 91.7 75.3 91.4 87.4 91.4 50.8 96.8 95.9 76.9 24.2 3400 75 3400 80 83.8 83.8 88.2 70.1 97.1 45.4 3400 85 89.4 89.4 89.6 88.4 97.7 64.1 3400 90 94.7 80.9 94.7 79.9 94.8 88.5 94.8 53.8 98.4 96.9 82.8 24.9 3740 75 3740 80 86.3 86.3 89.5 74.7 98.3 47.3 3740 85 92.0 92.0 91.9 91.9 99.0 68.3 3740 90 97.6 97.6 97.5 97.5 99.8 88.9 Notes: 82.5 82.5 89.6 56.3 97.6 26.0 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET 4080 75 cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate 4080 80 88.4 88.4 90.7 79.5 99.3 49.6 airflow table notes. 2. MBh = Total Gross Capacity 4080 85 94.2 94.2 94.0 94.0 100.1 72,6 3. SHC = Sensible Heat Capacity 4080 90 100.0 100.0 99.9 99.9 101.2 95.4 44 RT-PRCO23-EN A TRANE Performance Data Table 17. Gross cooling capacities 10 tons standard efficiency -three phase T/YSC12OE3,4,W Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 3200 75 109.5 90.4 120.7 66.7 132.6 42.6 102.9 87.0 113.5 63.3 124.9 39.5 95.8 83.3 105.9 59.9 116.7 36.2 3200 80 111.2 107.1 121.0 84.7 133.0 60.9 105.1 102.3 113.9 81.7 125.2 57.6 98.5 97.1 106.3 77.8 117.0 54.0 3200 85 115.9 115.9 121.5 103.0 133.2 78.9 110.1 110.1 114.3 99.6 125.5 75.5 103.8 103.8 106.8 96.2 117.3 72.0 3200 90 122.1 122.1 123.3 118.8 133.4 96.4 116.0 116.0 116.8 113.9 125.7 93.3 109.5 109.5 109.8 108.5 117.5 89.9 3600 75 111.9 96.8 123.1 70.8 135.1 43.3 105.1 93.4 115.7 66.7 127.0 39.9 97.9 89.7 107.9 63.3 118.7 36.8 3600 80 114.8 112.7 123.5 90.4 135.3 63.2 108.4 107.6 116.1 86.9 127.4 59.8 101.7 101.7 108.3 83.5 118.9 56.8 3600 85 120.5 120.5 124.1 111.0 140.9 98.6 114.3 114.3 116.8 107.7 132.4 95.2 107.7 107.7 109.3 103.4 123.4 91.9 3600 90 126.9 126.9 127.3 125.2 135.9 103.8 120.4 120.4 120.6 120.1 127.9 100.4 113.7 113.7 113.5 113.5 119.5 97.1 4000 75 114.1 103.3 125.1 73.7 137.0 43.8 107.1 99.8 117.5 70.1 128.9 40.8 100.0 95.0 109.5 66.4 120.3 37.3 4000 80 118.0 117.8 125.5 96.1 137.4 65.9 111.6 111.6 118.0 92.7 129.2 63.0 104.9 104.9 110.0 89.2 120.6 59.5 4000 85 124.4 124.4 126.3 118.8 137.8 88.8 118.0 118.0 119.4 113.7 129.6 85.4 111.1 111.1 111.9 108.2 120.9 82.1 4000 90 131.0 131.0 130.8 130.8 138.0 111.0 124.3 124.3 124.2 124.2 129.8 107.6 117.2 117.2 117.2 117.2 121.2 104.4 4400 75 116.1 109.4 126.8 76.9 138.7 44.6 109.2 104.2 119.0 73.9 130.4 41.2 102.0 98.7 110.8 69.7 121.5 37.5 4400 80 121.0 121.0 127.3 101.7 139.1 68.9 114.6 114.6 119.6 98.3 130.8 65.6 107.6 107.6 111.4 94.7 121.9 62.2 4400 85 127.8 127.8 129.1 123.7 139.4 94.6 121.1 121.1 121.9 118.5 131.1 90.2 113.9 113.9 114.3 112.7 122.2 86.9 4400 90 134.5 134.5 134.4 134.4 139.5 118.2 127.7 127.7 127.5 127.5 131.4 115.0 120.3 120.3 120.2 120.2 122.7 111.8 4800 75 118.0 113.1 128.2 80.3 140.2 45.2 111.5 108.0 120.3 77.0 131.7 42.2 103.9 102.3 112.0 73.1 122.6 38.6 4800 80 123.9 123.9 128.8 107.4 140.5 71.7 117.1 117.1 121.0 104.0 132.0 68.4 110.0 110.0 112.7 100.5 123.1 65.0 4800 85 130.8 130.8 131.6 128.4 140.9 98.6 123.9 123.9 124.2 122.8 132.4 95.2 116.5 116.5 116.5 116.5 123.4 91.9 4800 90 137.6 137.6 137.5 137.5 141.2 128.3 130.6 130.6 130.4 130.4 133.1 122.5 123.1 123.1 122.8 122.8 124.4 117.4 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 88.3 SHC 79.6 MBh 97.8 SHC 55.8 MBh 108.0 SHC 32.7 3200 75 3200 80 91.6 91.5 98.2 74.2 108.2 50.5 3200 85 97.1 97.1 98.8 92.6 108.5 68.4 3200 90 102.6 90.3 102.6 85.5 102.4 99.5 102.4 59.4 108.7 109.7 86.3 33.1 3600 75 3600 80 94.8 94.8 99.9 79.8 110.0 53.3 3600 85 100.6 100.6 101.5 97.7 113.9 88.1 3600 90 106.3 92.6 106.3 89.3 106.2 101.0 106.2 62.7 110.5 111.0 93.6 33.8 4000 75 4000 80 97.7 97.7 101.5 85.4 111.4 56.1 4000 85 103.7 103.7 104.0 102.3 111.7 78.4 4000 90 109.5 94.5 109.5 93.0 109.4 102.2 109.4 66.1 112.0 112.2 101.1 33.8 4400 75 4400 80 100.2 100.2 102.8 91.2 112.6 58.8 4400 85 106.3 106.3 106.3 106.2 112.9 83.2 4400 90 112.4 96.3 112.4 96.0 112.2 103.2 112.2 69.4 113.6 113.1 107.2 34.7 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET 4800 75 cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate 4800 80 102.4 102.4 104.0 96.9 113.6 61.5 airflow table notes. 2. MBh = Total Gross Capacity 4800 85 108.6 108.6 108.5 108.5 113.9 88.1 3. SHC =Sensible Heat Capacity 4800 90 114.7 114.7 114.6 114.6 115.5 111.1 RT-PRCO23-EN 45 M TRAME WF Performance Data Table 18. Gross cooling capacities 3 tons standard efficiency - single phase WSC036E1 - heat pump Flow I DB 1 61 cfm (F) MBh SHC 1080 75 35.7 28.7 1080 80 36.7 35.8 1080 85 38.9 38.9 1080 90 41.3 41.3 1200 75 36.5 30.6 1200 80 37.8 37.8 1200 85 40.4 40.4 1200 90 42.9 42.9 1320 75 37.3 32.5 1320 80 39.1 39.1 1320 85 41.7 41.7 1320 90 44.3 44.3 1440 75 38.0 34.7 1440 80 40.1 40.1 1440 85 42.8 42.8 1440 90 45.5 45.5 Flow DB 61 cfm (F) MBh Ambient Temperature 85 67 73 1 61 67 MBh SHC MBh SHC MBh SHC MBh SHC 39.4 20.8 43.3 12.2 32.9 27.1 36.4 19.2 39.9 27.0 43.9 19.0 34.0 34.0 36.9 25.5 40.5 33.1 44.3 25.1 36.3 36.3 37.5 31.6 41.6 40.4 44.9 31.3 38.7 38.7 38.7 38.6 40.2 21.9 44.1 12.5 33.7 29.0 37.0 20.2 40.8 28.7 44.6 19.9 35.3 35.3 37.6 27.1 41.5 35.5 45.1 26.5 37.7 37.7 38.4 34.2 42.9 42.9 45.8 33.1 40.2 40.2 40.1 40.1 40.8 22.7 44.7 12.6 34.4 31.2 37.6 21.0 41.4 30.2 45.3 20.7 36.4 36.4 38.2 28.5 42.3 38.2 45.9 27.9 38.9 38.9 39.3 37.0 44.3 44.3 46.5 35.0 41.5 41.5 41.4 41.4 41.3 23.6 45.2 12.8 35.1 33.4 38.1 22.0 42.0 31.7 45.9 21.6 37.4 37.4 38.9 30.2 43.2 41.0 46.5 29.1 40.0 40.0 40.0 39.6 45.5 45.5 47.2 37.1 42.6 42.6 42.6 42.6 nt Temperature 67 73 1080 80 28.6 28.6 30.5 22.3 33.8 14.6 1080 85 30.8 30.8 31.3 28.9 34.2 20.5 1080 90 33.1 33.1 33.1 33.1 34.7 26.3 73 61 67 73 MBh SHC MBh SHC MBh SHC MBh SHC 40.1 10.9 30.0 25.5 33.2 17.7 36.8 9.3 40.7 17.6 31.4 31.4 33.8 23.9 37.3 16.1 41.1 23.6 33.7 33.7 34.4 30.1 37.7 22.1 41.7 29.7 36.0 36.0 36.0 36.0 38.3 28.1 40.8 11.0 30.8 27.7 33.8 18.5 37.4 9.5 41.4 18.5 32.6 32.6 34.5 25.4 37.9 17.0 41.9 25.0 35.0 35.0 35.3 33.0 38.4 23.4 42.4 31.5 37.3 37.3 37.3 37.3 39.0 29.9 41.4 11.0 31.5 29.9 34.4 19.5 37.9 9.8 41.9 19.3 33.6 33.6 35.0 27.0 38.4 17.7 42.5 26.3 36.0 36.0 36.2 35.7 39.0 24.8 43.2 33.5 38.5 38.5 38.5 38.5 39.7 32.1 41.9 11.4 32.1 31.8 34.8 20.6 38.3 9.8 42.4 20.0 34.5 34.5 35.5 28.7 38.8 18.1 43.1 27.8 37.0 37.0 37.0 37.0 39.5 26.2 43.8 35.7 39.5 39.5 39.5 39.5 40.3 34.6 1200 80 29.7 29.7 31.1 23.7 34.3 15.3 1200 85 32.0 32.0 32.1 31.7 34.8 22.1 1200 90 34.3 34.3 34.3 34.3 35.4 28.5 1320 75 28.4 28.3 30.9 18.0 34.2 8.1 1320 80 30.7 30.7 31.6 25.4 34.7 15.8 1320 85 33.0 33.0 33.0 33.0 35.3 23.3 1320 90 35.3 35.3 35.3 35.3 36.1 30.9 1440 75 29.0 29.0 31.3 18.9 34.6 8.1 1440 80 31.4 31.4 32.1 27.3 35.1 16.5 1440 85 33.9 33.9 33.8 33.8 35.7 24.5 1440 90 36.3 36.3 36.2 36.2 36.7 33.6 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity 46 RT-PRCO23-EN A TRANE Performance Data Table 19. Gross cooling capacities 3 tons standard efficiency -three phase WSC036E3,4,W - heat pump Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1080 75 36.1 28.9 39.8 21.0 43.6 12.3 33.3 27.4 36.8 19.2 40.4 10.7 30.4 25.8 33.6 17.9 37.1 9.1 1080 80 36.9 35.9 40.2 27.0 44.2 19.2 34.2 34.1 37.3 25.5 41.0 17.6 31.6 31.6 34.1 23.9 37.6 15.8 1080 85 38.9 38.9 40.7 33.3 44.6 25.0 36.4 36.4 37.8 31.8 41.4 23.8 33.8 33.8 34.6 30.3 38.0 22.2 1080 90 41.3 41.3 41.6 40.5 45.1 31.1 38.7 38.7 38.8 38.6 41.9 29.7 36.0 36.0 36.0 36.0 38.4 28.0 1200 75 36.9 30.9 40.6 21.8 44.4 12.4 34.1 29.4 37.5 20.3 41.2 10.8 31.1 28.0 34.3 18.8 37.7 9.3 1200 80 38.0 37.9 41.1 28.7 45.0 19.7 35.4 35.4 38.0 27.3 41.7 18.3 32.7 32.7 34.7 25.6 38.2 16.8 1200 85 40.4 40.4 41.7 35.7 45.5 26.8 37.8 37.8 38.7 34.5 42.1 24.9 35.0 35.0 35.5 33.2 38.6 23.4 1200 90 42.9 42.9 42.9 42.9 46.0 33.3 40.3 40.3 40.2 40.2 42.6 31.7 37.3 37.3 37.3 37.3 39.1 30.1 1320 75 37.6 32.9 41.3 22.9 45.1 12.5 34.8 31.6 38.1 21.3 41.8 11.0 31.7 30.1 34.8 19.7 38.2 9.4 1320 80 39.2 39.2 41.9 30.4 45.7 20.8 36.6 36.6 38.7 28.9 42.3 19.2 33.7 33.7 35.4 27.2 38.7 17.4 1320 85 41.8 41.8 42.5 38.5 46.2 27.9 39.0 39.0 39.4 37.2 42.8 26.4 36.1 36.1 36.3 35.8 39.2 24.8 1320 90 44.4 44.4 44.3 44.3 46.7 35.2 41.5 41.5 41.5 41.5 43.3 33.7 38.5 38.5 38.5 38.5 39.8 32.3 1440 75 38.4 35.1 41.9 23.9 45.7 12.7 35.4 33.7 38.6 22.3 42.3 11.2 32.4 31.9 35.2 20.6 38.7 9.3 1440 80 40.3 40.3 42.5 32.1 46.3 21.6 37.6 37.6 39.2 30.4 42.8 20.0 34.6 34.6 35.8 29.0 39.1 18.3 1440 85 42.9 42.9 43.3 41.2 46.9 29.3 40.1 40.1 40.3 39.7 43.3 27.8 37.1 37.1 37.1 37.0 39.7 26.4 1440 90 45.6 45.6 45.5 45.5 47.5 37.3 42.6 42.6 42.6 42.6 44.0 35.9 39.5 39.5 39.5 39.5 40.4 34.9 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 27.3 SHC 24.4 MBh 30.4 SHC 16.3 MBh 33.6 SHC 7.6 1080 75 1080 80 28.8 28.8 30.7 22.3 34.0 14.3 1080 85 31.0 31.0 31.4 29.1 34.4 20.3 1080 90 33.1 28.0 33.1 26.6 33.1 30.9 33.1 17.1 34.8 34.1 26.4 7.8 1200 75 1200 80 29.9 29.9 31.4 24.0 34.6 15.0 1200 85 32.1 32.1 32.2 31.8 35.0 21.7 1200 90 34.3 28.7 34.3 28.3 34.3 31.4 34.3 18.0 35.5 34.6 28.5 8.0 1320 75 1320 80 30.8 30.8 31.9 25.7 35.0 15.8 1320 85 33.1 33.1 33.1 33.0 35.5 23.2 1320 90 35.3 29.3 35.3 29.2 35.3 31.8 35.3 19.0 36.1 34.9 31.1 7.9 1440 75 1440 80 31.6 31.6 32.4 27.6 35.4 16.5 1440 85 33.9 33.9 33.9 33.9 35.9 24.6 1440 90 36.2 36.2 36.2 36.2 36.6 33.8 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity RT-PRCO23-EN 47 M TRAME WF Performance Data Table 20. Gross cooling capacities 4 tons standard efficiency - single phase WSC048E1 - heat pump Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1440 75 46.3 39.0 51.1 28.2 56.2 16.8 43.0 37.1 47.6 26.3 52.4 14.6 39.5 35.1 43.8 24.7 48.4 13.0 1440 80 47.1 45.9 51.6 36.7 56.8 25.8 44.0 43.5 48.1 34.8 53.0 24.1 40.7 40.7 44.3 33.0 49.0 22.3 1440 85 49.6 49.6 52.2 45.0 57.3 34.3 46.7 46.7 48.7 43.2 53.4 32.1 43.6 43.6 44.9 41.3 49.4 30.7 1440 90 52.7 52.7 53.2 51.9 57.8 42.4 49.7 49.7 49.8 49.4 54.0 40.6 46.5 46.5 46.4 46.4 49.8 38.9 1600 75 47.3 41.6 52.1 29.5 57.3 17.3 43.9 39.6 48.5 27.9 53.3 14.9 40.4 37.4 44.6 26.1 49.2 12.1 1600 80 48.5 48.2 52.7 39.0 57.9 26.9 45.3 45.3 49.0 37.2 53.9 25.2 42.2 42.2 45.2 35.3 49.8 23.4 1600 85 51.5 51.5 53.3 48.2 58.3 36.2 48.4 48.4 49.8 46.2 54.4 34.4 45.2 45.2 46.0 43.8 50.3 32.7 1600 90 54.7 54.7 54.8 54.6 58.9 45.4 51.5 51.5 51.5 51.5 54.9 43.6 48.2 48.2 48.2 48.2 50.7 41.8 1760 75 48.2 43.8 53.0 31.0 58.1 17.0 44.8 41.7 49.2 29.3 54.2 16.4 41.1 39.2 45.3 27.5 50.0 14.1 1760 80 49.9 49.9 53.6 41.4 58.7 28.0 46.8 46.8 49.9 39.6 54.7 26.3 43.5 43.5 45.9 37.7 50.5 24.7 1760 85 53.2 53.2 54.4 50.9 59.2 38.1 50.0 50.0 50.8 48.5 55.2 36.5 46.6 46.6 47.0 45.7 50.9 34.8 1760 90 56.4 56.4 56.4 56.4 59.8 48.4 53.2 53.2 53.1 53.1 55.7 46.5 49.6 49.6 49.6 49.6 51.5 44.9 1920 75 49.0 45.9 53.7 32.6 58.9 18.0 45.6 43.4 49.9 30.8 54.8 16.3 41.9 40.7 45.8 28.9 50.5 14.6 1920 80 51.2 51.2 54.4 43.6 59.5 29.1 48.0 48.0 50.5 41.9 55.4 27.4 44.6 44.6 46.5 39.9 51.0 25.9 1920 85 54.6 54.6 55.4 53.1 60.0 40.2 51.3 51.3 51.7 50.4 55.9 38.6 47.8 47.8 47.9 47.6 51.5 36.9 1920 90 58.0 58.0 58.0 58.0 60.6 51.3 54.6 54.6 54.5 54.5 56.6 49.5 51.0 51.0 50.9 50.9 52.2 47.4 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 35.8 SHC 33.0 MBh 39.8 SHC 22.8 MBh 44.3 SHC 12.2 1440 75 1440 80 37.5 37.5 40.3 31.2 44.7 20.5 1440 85 40.2 40.2 41.0 39.0 45.1 28.8 1440 90 43.0 36.6 43.0 34.8 43.0 40.5 43.0 24.1 45.5 44.9 37.1 13.4 1600 75 1600 80 38.8 38.8 41.1 33.5 45.4 21.7 1600 85 41.7 41.7 42.1 41.0 45.8 30.9 1600 90 44.6 37.4 44.6 36.4 44.6 41.1 44.6 25.6 46.3 45.5 40.1 12.6 1760 75 1760 80 40.0 40.0 41.7 35.8 46.0 22.9 1760 85 42.9 42.9 43.0 42.8 46.4 33.0 1760 90 45.9 38.1 45.9 37.8 45.9 41.6 45.9 27.1 47.1 46.0 42.8 12.8 1920 75 1920 80 41.0 41.0 42.3 37.8 46.5 23.9 1920 85 44.1 44.1 44.0 44.0 47.0 35.0 1920 90 47.1 47.1 47.1 47.1 47.8 44.9 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity 48 RT-PRCO23-EN A TRANE Performance Data Table 21. Gross cooling capacities 4 tons standard efficiency -three phase WSC048E3,4,W -heat pump Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1440 75 47.2 39.3 52.1 28.6 57.4 17.1 43.8 37.4 48.6 26.7 53.6 15.3 40.3 35.5 44.8 24.9 49.6 13.9 1440 80 48.1 46.7 52.7 37.0 57.9 25.7 44.8 44.2 49.1 35.2 54.2 24.1 41.5 41.5 45.3 33.4 50.1 22.3 1440 85 50.6 50.6 53.3 45.5 58.5 34.0 47.6 47.6 49.7 43.6 54.7 32.5 44.4 44.4 45.9 41.8 50.7 30.7 1440 90 53.7 53.7 54.3 52.7 59.0 42.4 50.6 50.6 50.9 50.2 55.2 41.0 47.4 47.4 47.4 47.4 51.2 39.3 1600 75 48.3 42.0 53.2 29.9 58.5 18.1 44.8 40.0 49.5 28.2 54.6 16.3 41.2 37.9 45.6 26.1 50.5 14.7 1600 80 49.5 49.0 53.8 39.4 59.0 26.3 46.2 46.2 50.1 37.6 55.1 24.4 43.0 43.0 46.3 35.8 51.1 23.6 1600 85 52.5 52.5 54.5 48.8 59.6 36.1 49.4 49.4 50.8 46.8 55.7 34.5 46.1 46.1 47.0 44.5 51.6 32.8 1600 90 55.8 55.8 55.8 55.4 60.2 45.6 52.5 52.5 52.5 52.5 56.2 44.0 49.2 49.2 49.2 49.2 52.0 42.2 1760 75 49.3 44.5 54.1 31.1 59.4 19.0 45.7 42.3 50.3 29.6 55.4 16.5 42.0 39.9 46.3 27.5 51.2 14.5 1760 80 50.8 50.8 54.7 41.8 60.0 28.4 47.7 47.7 51.0 39.9 55.9 26.5 44.4 44.4 47.0 38.0 51.8 24.5 1760 85 54.2 54.2 55.5 51.7 60.5 38.3 51.0 51.0 51.9 49.3 56.5 36.7 47.6 47.6 48.0 46.5 52.4 35.0 1760 90 57.6 57.6 57.5 57.5 61.2 48.7 54.2 54.2 54.2 54.2 57.1 46.9 50.8 50.8 50.8 50.8 52.9 45.3 1920 75 50.1 46.6 54.9 32.7 60.2 19.3 46.5 44.2 51.0 31.0 56.1 18.2 42.8 41.4 46.9 29.0 51.9 14.7 1920 80 52.2 52.2 55.5 44.1 60.8 29.6 49.0 49.0 51.7 42.3 56.6 27.4 45.6 45.6 47.6 40.3 52.4 25.6 1920 85 55.7 55.7 56.5 53.9 61.3 40.3 52.4 52.4 52.8 51.2 57.2 38.9 48.9 48.9 49.1 48.5 53.0 37.1 1920 90 59.2 59.2 59.1 59.1 62.0 51.7 55.7 55.7 55.7 55.7 58.0 50.0 52.2 52.2 52.1 52.1 53.7 48.1 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 36.6 SHC 33.5 MBh 40.8 SHC 23.0 MBh 45.4 SHC 12.1 1440 75 1440 80 38.3 38.3 41.3 31.4 45.9 20.6 1440 85 41.1 41.1 42.0 39.6 46.4 29.0 1440 90 44.0 37.4 44.0 35.5 44.0 41.5 44.0 24.4 46.9 46.1 37.4 12.9 1600 75 1600 80 39.7 39.7 42.1 33.8 46.7 21.6 1600 85 42.7 42.7 43.1 41.7 47.2 31.1 1600 90 45.7 38.3 45.7 37.1 45.6 42.2 45.6 25.9 47.7 46.8 40.4 13.0 1760 75 1760 80 40.9 40.9 42.8 36.1 47.3 22.8 1760 85 44.0 44.0 44.1 43.7 47.9 33.0 1760 90 47.1 39.1 47.1 38.6 47.1 42.7 47.1 27.2 48.6 47.3 43.5 13.0 1920 75 1920 80 42.0 42.0 43.4 38.4 47.9 24.0 1920 85 45.2 45.2 45.2 45.2 48.4 35.3 1920 90 48.4 48.4 48.4 48.4 49.3 45.9 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity RT-PRCO23-EN 49 M TRAME WF Performance Data Table 22. Gross cooling capacities 5 tons standard efficiency - single phase WSC060E1 - heat pump Ambient Temperature 85 95 1 Flow DB 61 67 cfm (F) MBh SHC MBh 1800 75 55.3 46.9 60.3 1800 80 57.1 56.3 61.3 1800 85 60.4 60.4 62.6 1800 90 64.1 64.1 64.5 2000 75 56.6 50.2 61.4 2000 80 58.7 58.6 62.6 2000 85 62.4 62.4 64.0 2000 90 66.4 66.4 66.4 2200 75 57.7 53.0 62.4 2200 80 60.2 60.2 63.6 2200 85 64.3 64.3 65.3 2200 90 68.3 68.3 68.3 2400 75 58.5 55.4 63.2 2400 80 61.8 61.8 64.6 2400 85 65.9 65.9 66.5 2400 90 70.1 70.1 70.0 73 61 67 SHC MBh SHC MBh SHC MBh SHC 32.1 65.7 17.3 51.5 44.9 56.2 30.5 43.1 67.0 29.4 53.4 53.2 57.2 41.1 54.5 67.9 39.5 56.8 56.8 58.4 52.5 63.6 69.0 50.1 60.4 60.4 60.5 60.3 33.8 66.9 17.6 52.6 47.9 57.2 31.7 45.9 68.2 30.0 55.0 55.0 58.4 44.3 58.3 69.1 41.5 58.7 58.7 59.8 56.0 66.3 70.3 53.8 62.5 62.5 62.5 62.5 35.5 67.9 17.9 53.7 50.7 58.0 33.5 48.9 69.2 31.2 56.5 56.5 59.3 47.0 61.6 70.1 44.5 60.4 60.4 61.0 59.0 68.3 71.4 57.2 64.3 64.3 64.3 64.3 37.2 68.8 17.1 54.5 52.8 58.8 35.2 51.7 70.1 32.6 57.9 57.9 60.1 49.8 64.5 71.1 45.9 61.9 61.9 62.2 61.5 70.0 72.6 61.3 65.9 65.9 65.9 65.9 iperature Air tnt tntering wet tsuiD Flow DB 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC 1800 80 45.8 45.8 48.2 37.2 52.7 22.8 1800 85 49.0 49.0 49.6 47.6 53.6 33.8 1800 90 52.4 52.4 52.4 52.4 54.5 44.5 73 1 61 67 73 MBh SHC MBh SHC MBh SHC MBh SHC 61.3 15.7 47.4 42.9 51.8 27.8 56.7 13.8 62.4 26.7 49.6 49.6 52.8 39.3 57.7 24.8 63.4 37.3 53.0 53.0 54.1 50.3 58.6 35.4 64.4 48.3 56.6 56.6 56.5 56.5 59.6 46.4 62.4 15.9 48.5 45.6 52.7 29.7 57.6 13.8 63.5 28.6 51.2 51.2 53.8 42.2 58.7 25.5 64.5 39.7 54.8 54.8 55.4 53.4 59.6 38.0 65.6 51.8 58.4 58.4 58.4 58.4 60.7 50.2 63.3 15.1 49.5 47.9 53.5 31.3 58.4 14.2 64.5 29.4 52.6 52.6 54.7 45.0 59.4 27.1 65.5 42.1 56.4 56.4 56.6 55.9 60.5 40.5 66.7 55.7 60.1 60.1 60.0 60.0 61.8 53.9 64.2 15.4 50.4 49.7 54.2 33.2 59.1 13.8 65.2 30.6 53.8 53.8 55.5 47.9 60.1 28.9 66.3 45.0 57.7 57.7 57.7 57.5 61.2 43.1 67.7 59.4 61.5 61.5 61.5 61.5 62.7 57.2 2000 80 47.2 47.2 49.1 40.2 53.5 24.3 2000 85 50.6 50.6 50.8 50.2 54.4 36.1 2000 90 54.0 54.0 54.0 54.0 55.6 48.3 2200 75 45.2 44.7 48.6 29.2 53.2 12.6 2200 80 48.4 48.4 49.9 43.1 54.1 25.3 2200 85 51.9 51.9 52.0 51.9 55.2 38.7 2200 90 55.5 55.5 55.5 55.5 56.5 51.7 2400 75 46.0 45.8 49.3 31.1 53.8 12.9 2400 80 49.5 49.5 50.5 45.6 54.7 26.7 2400 85 53.1 53.1 53.1 53.1 55.8 41.2 2400 90 56.8 56.8 56.7 56.7 57.4 54.5 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity 50 RT-PRCO23-EN A TRANE Performance Data Table 23. Gross cooling capacities 5 tons standard efficiency -three phase WSC060E3,4,W - heat pump Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1800 75 59.6 49.6 66.0 35.9 72.6 21.9 55.6 47.4 61.6 34.4 68.0 20.0 51.5 45.3 57.1 31.8 63.2 18.0 1800 80 61.1 61.0 66.5 46.6 73.5 33.7 57.5 57.5 62.2 44.4 68.9 31.7 53.8 53.8 57.7 42.3 63.9 29.1 1800 85 64.9 64.9 67.3 57.1 73.9 43.3 61.3 61.3 63.0 55.0 69.2 41.3 57.5 57.5 58.6 53.1 64.3 39.3 1800 90 68.9 68.9 69.0 68.9 74.7 53.8 65.2 65.2 65.1 65.1 69.9 51.7 61.3 61.3 61.2 61.2 65.1 49.6 2000 75 61.0 52.9 67.1 37.7 74.0 22.1 56.9 50.8 62.7 35.8 69.2 20.2 52.7 49.0 58.0 33.5 64.2 18.5 2000 80 63.2 63.2 67.8 49.4 74.9 35.2 59.6 59.6 63.4 47.2 70.0 32.6 55.7 55.7 58.8 45.1 64.9 31.1 2000 85 67.4 67.4 68.9 61.3 75.3 45.9 63.6 63.6 64.5 59.6 70.5 43.7 59.6 59.6 60.0 58.3 65.5 41.7 2000 90 71.5 71.5 71.4 71.4 76.1 57.2 67.7 67.7 67.5 67.5 71.3 55.1 63.5 63.5 63.4 63.4 66.3 52.8 2200 75 62.2 56.4 68.3 39.6 75.1 22.4 58.1 54.6 63.7 37.2 70.3 20.5 53.8 52.8 58.9 35.1 65.1 18.5 2200 80 65.2 65.2 69.0 52.1 75.9 36.8 61.4 61.4 64.4 49.9 71.0 33.9 57.4 57.4 59.7 47.8 65.8 31.8 2200 85 69.5 69.5 70.3 66.1 76.5 48.3 65.6 65.6 66.1 64.8 71.5 46.0 61.4 61.4 61.4 61.4 66.5 44.1 2200 90 73.8 73.8 73.8 73.8 77.4 60.7 69.8 69.8 69.7 69.7 72.5 58.6 65.5 65.5 65.4 65.4 67.4 56.7 2400 75 63.4 60.2 69.0 40.9 76.0 22.7 59.2 58.3 64.5 38.8 71.1 20.7 54.9 54.8 59.6 36.7 65.9 18.7 2400 80 66.9 66.9 70.1 54.9 76.8 37.2 63.0 63.0 65.4 52.8 71.8 35.9 58.9 58.9 60.6 50.8 66.6 33.6 2400 85 71.3 71.3 71.8 70.9 77.6 50.5 67.3 67.3 67.4 67.3 72.5 48.6 63.0 63.0 63.0 63.0 67.3 46.3 2400 90 75.9 75.9 75.8 75.8 78.6 64.3 71.7 71.7 71.6 71.6 73.6 62.5 67.2 67.2 67.2 67.2 68.5 60.9 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh 47.1 SHC 43.2 MBh 52.2 SHC 29.6 MBh 58.0 SHC 16.1 1800 75 1800 80 49.9 49.9 52.8 40.1 58.7 27.5 1800 85 53.4 53.4 53.9 51.7 59.1 37.2 1800 90 57.0 48.3 57.0 47.2 57.0 53.2 57.0 31.5 59.9 58.9 47.2 16.3 2000 75 2000 80 51.6 51.6 53.8 42.8 59.6 28.9 2000 85 55.3 55.3 55.4 55.3 60.2 39.5 2000 90 59.1 49.4 59.1 49.4 59.1 53.9 59.1 33.2 61.0 59.7 50.8 16.2 2200 75 2200 80 53.1 53.1 54.7 45.7 60.4 29.7 2200 85 57.0 57.0 56.9 56.9 61.0 41.9 2200 90 60.9 50.5 60.9 50.5 60.9 54.5 60.9 34.3 62.1 60.3 54.9 16.3 2400 75 2400 80 54.4 54.4 55.6 48.9 61.0 30.8 2400 85 58.5 58.5 58.4 58.4 61.8 44.3 2400 90 62.5 62.5 62.5 62.5 63.1 59.7 Note: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity RT-PRCO23-EN 51 M TRAME WF Performance Data Table 24. Gross cooling capacities 3 tons high efficiency -single phase T/YHC036El Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1080 75 35.98 29.32 39.78 21.77 43.79 13.23 33.67 28.00 37.32 20.42 41.12 11.60 31.24 26.70 34.66 18.96 38.27 10.50 1080 80 36.75 36.14 40.21 27.81 44.32 18.70 34.62 34.55 37.70 26.35 41.66 19.19 32.42 32.42 35.09 24.88 38.87 17.42 1080 85 38.97 38.97 40.68 33.98 44.77 26.20 36.89 36.89 38.20 32.60 42.07 24.89 34.66 34.66 35.59 31.36 39.20 23.34 1080 90 41.37 41.37 41.55 40.89 45.12 32.03 39.22 39.22 39.19 39.15 42.48 30.69 36.92 36.92 36.88 36.88 39.58 29.15 1200 75 36.80 31.29 40.58 22.70 44.56 13.08 34.51 30.19 38.04 21.35 41.82 12.07 31.94 28.81 35.33 19.89 38.93 10.74 1200 80 37.98 37.98 41.02 29.37 45.25 19.91 35.87 35.87 38.49 27.95 42.46 19.36 33.61 33.61 35.81 26.49 39.52 18.36 1200 85 40.43 40.43 41.60 36.52 45.62 27.66 38.29 38.29 39.06 35.26 42.84 26.24 35.97 35.97 36.43 34.19 39.90 24.63 1200 90 42.94 42.94 42.92 42.92 46.01 34.09 40.67 40.67 40.69 40.69 43.25 32.66 38.29 38.29 38.28 38.28 40.34 31.25 1320 75 37.56 33.62 41.24 23.67 45.25 13.35 35.13 32.23 38.65 21.93 42.41 12.25 32.61 30.88 35.92 20.85 39.47 10.65 1320 80 39.19 39.19 41.74 30.99 45.98 22.46 37.00 37.00 39.13 29.55 43.09 20.28 34.66 34.66 36.38 28.25 40.09 19.09 1320 85 41.76 41.76 42.39 39.18 46.35 29.03 39.52 39.52 39.89 38.00 43.49 27.42 37.10 37.10 37.20 36.47 40.52 25.74 1320 90 44.30 44.30 44.29 44.29 46.76 36.00 42.01 42.01 41.98 41.98 43.93 34.80 39.55 39.55 39.51 39.51 40.99 33.52 1440 75 38.21 35.56 41.79 24.49 45.87 13.71 35.79 34.23 39.17 23.63 42.95 12.14 33.22 32.55 36.38 21.75 39.93 10.77 1440 80 40.26 40.26 42.38 32.66 46.51 22.10 38.00 38.00 39.72 31.36 43.60 20.97 35.58 35.58 36.92 30.15 40.56 19.85 1440 85 42.94 42.94 43.26 41.79 46.93 30.25 40.60 40.60 40.67 40.12 44.03 28.88 38.09 38.09 38.12 38.10 41.01 27.36 1440 90 45.57 45.57 45.52 45.52 47.42 38.18 43.15 43.15 43.15 43.15 44.56 37.07 40.63 40.63 40.60 40.60 41.57 36.03 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC 28.69 25.46 31.92 17.50 35.30 9.16 1080 75 1080 80 30.12 30.12 32.30 23.39 35.87 16.22 1080 85 32.31 32.31 32.84 30.14 36.22 21.81 1080 90 34.47 34.47 34.45 34.45 36.59 27.68 29.36 27.53 32.47 18.40 35.89 8.96 1200 75 1200 80 31.22 31.22 32.95 25.14 36.47 16.48 1200 85 33.50 33.50 33.70 32.88 36.84 23.18 1200 90 35.78 35.78 35.75 35.75 37.28 29.77 30.02 29.35 32.97 19.05 36.36 9.31 1320 75 1320 80 32.18 32.18 33.47 26.95 36.96 17.31 1320 85 34.54 34.54 34.55 34.52 37.37 24.62 1320 90 36.90 36.90 36.87 36.87 37.87 32.39 30.66 30.61 33.40 20.29 36.76 9.40 1440 75 1440 80 33.03 33.03 33.96 28.89 37.38 18.26 1440 85 35.46 35.46 35.43 35.43 37.85 25.96 1440 90 37.89 37.89 37.86 37.86 38.47 34.85 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity 52 RT-PRCO23-EN A TRANE Performance Data Table 25. Gross cooling capacities 3 tons high efficiency - three phase T/YHC036E,3A Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1080 75 36.04 29.24 39.93 21.85 44.03 13.31 33.56 27.96 37.25 19.68 41.15 11.98 30.96 26.64 34.44 18.63 38.07 10.45 1080 80 36.85 36.25 40.36 27.79 44.56 18.86 34.54 34.48 37.71 26.33 41.72 19.22 32.17 32.17 34.87 24.79 38.71 17.22 1080 85 39.07 39.07 40.89 34.02 45.02 26.27 36.85 36.85 38.21 32.58 42.13 24.91 34.48 34.48 35.39 31.27 39.05 23.28 1080 90 41.51 41.51 41.71 40.92 45.41 32.17 39.24 39.24 39.24 39.18 42.52 30.76 36.78 36.78 36.75 36.75 39.44 29.08 1200 75 36.89 31.39 40.75 22.78 44.80 13.19 34.36 30.13 38.02 21.34 41.86 12.08 31.63 28.72 35.11 19.72 38.73 10.53 1200 80 38.07 38.07 41.22 29.43 45.44 21.73 35.82 35.82 38.49 27.94 42.51 19.35 33.39 33.39 35.57 26.40 39.36 18.31 1200 85 40.58 40.58 41.79 36.51 45.90 27.82 38.27 38.27 39.04 35.24 42.91 26.26 35.80 35.80 36.22 34.00 39.75 24.57 1200 90 43.14 43.14 43.10 43.10 46.32 34.18 40.75 40.75 40.71 40.71 43.32 32.62 38.18 38.18 38.15 38.15 40.20 31.10 1320 75 37.67 33.65 41.43 23.65 45.47 13.24 35.04 32.16 38.64 21.93 42.46 12.26 32.35 30.88 35.69 20.75 39.29 10.60 1320 80 39.27 39.27 41.95 31.06 46.28 22.55 36.96 36.96 39.15 29.59 43.13 20.50 34.44 34.44 36.18 28.17 39.93 19.03 1320 85 41.94 41.94 42.64 39.23 46.63 29.16 39.54 39.54 39.90 38.01 43.54 27.46 36.94 36.94 37.05 36.38 40.35 26.01 1320 90 44.51 44.51 44.50 44.50 47.07 36.09 42.08 42.08 42.02 42.02 44.03 34.82 39.42 39.42 39.40 39.40 40.86 33.49 1440 75 38.28 35.59 42.01 24.58 46.08 13.79 35.73 34.21 39.17 23.62 43.00 12.15 32.96 32.43 36.15 21.66 39.73 10.77 1440 80 40.43 40.43 42.60 32.73 46.77 21.55 37.97 37.97 39.77 31.36 43.69 20.99 35.39 35.39 36.72 30.03 40.41 19.49 1440 85 43.13 43.13 43.49 41.88 47.26 30.64 40.62 40.62 40.78 40.21 44.14 28.86 37.94 37.94 37.95 37.94 40.89 27.31 1440 90 45.81 45.81 45.77 45.77 47.72 38.26 43.26 43.26 43.23 43.23 44.68 37.16 40.53 40.53 40.49 40.49 41.48 35.99 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC 28.08 25.17 31.38 17.36 34.83 9.03 1080 75 1080 80 29.66 29.66 31.82 23.19 35.43 15.97 1080 85 31.91 31.91 32.40 30.00 35.81 21.66 1080 90 34.14 34.14 34.11 34.11 36.18 27.54 28.80 27.28 31.99 18.16 35.42 8.84 1200 75 1200 80 30.78 30.78 32.47 24.98 36.01 16.40 1200 85 33.12 33.12 33.29 32.64 36.43 23.02 1200 90 35.44 35.44 35.41 35.41 36.88 29.78 29.47 29.03 32.47 18.66 35.91 9.51 1320 75 1320 80 31.75 31.75 32.98 26.77 36.51 17.18 1320 85 34.17 34.17 34.16 34.15 36.98 24.18 1320 90 36.56 36.56 36.53 36.53 37.46 32.20 30.16 30.15 32.90 20.10 36.30 9.28 1440 75 1440 80 32.60 32.60 33.49 28.79 36.94 17.90 1440 85 35.10 35.10 35.07 35.07 37.48 25.84 1440 90 37.55 37.55 37.52 37.52 38.10 34.84 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity RT-PRCO23-EN 53 M TRAME WF Performance Data Table 26. Gross cooling capacities 4 tons high efficiency - three phase T/YHC048E1 Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1440 75 45.95 38.53 50.74 26.84 55.90 16.12 42.93 36.94 47.50 26.09 52.40 14.52 39.78 35.43 44.04 23.93 48.77 13.50 1440 80 46.89 46.79 51.26 35.91 56.52 24.30 44.12 44.12 48.00 34.31 53.00 22.82 41.26 41.26 44.52 32.74 49.25 21.85 1440 85 49.73 49.73 51.82 44.43 56.96 32.82 47.00 47.00 48.58 42.98 53.46 31.57 44.09 44.09 45.12 41.45 49.74 30.00 1440 90 52.73 52.73 52.79 52.72 57.39 41.60 49.94 49.94 49.88 49.88 53.86 39.86 46.92 46.92 46.88 46.88 50.10 38.35 1600 75 46.99 41.23 51.75 28.58 56.91 16.22 43.87 39.64 48.39 27.17 53.34 14.69 40.62 38.08 44.86 25.58 49.54 13.15 1600 80 48.44 48.44 52.28 38.10 57.59 25.94 45.69 45.69 48.93 36.67 53.95 24.16 42.78 42.78 45.34 35.00 50.14 21.89 1600 85 51.56 51.56 52.94 47.80 58.01 35.11 48.72 48.72 49.67 46.46 54.43 33.62 45.68 45.68 46.17 44.82 50.58 31.94 1600 90 54.71 54.71 54.66 54.66 58.50 44.49 51.77 51.77 51.74 51.74 54.89 42.95 48.63 48.63 48.56 48.56 51.07 41.40 1760 75 47.91 43.99 52.59 29.89 57.79 16.41 44.76 42.38 49.17 28.47 54.13 14.85 41.39 40.38 45.52 26.95 50.25 13.33 1760 80 49.96 49.96 53.17 40.50 58.39 25.91 47.09 47.09 49.71 38.94 54.76 24.43 44.03 44.03 46.08 37.35 50.86 23.65 1760 85 53.16 53.16 54.00 51.28 58.92 37.01 50.23 50.23 50.64 49.53 55.23 35.54 47.07 47.07 47.12 47.07 51.32 34.02 1760 90 56.43 56.43 56.39 56.39 59.42 47.53 53.38 53.38 53.35 53.35 55.81 45.95 50.17 50.17 50.06 50.06 51.81 44.40 1920 75 48.70 46.51 53.33 31.37 58.51 16.55 45.48 44.48 49.84 29.84 54.84 15.12 42.16 42.08 46.13 28.31 50.89 14.62 1920 80 51.26 51.26 53.94 42.84 59.16 27.60 48.33 48.33 50.45 41.30 55.45 26.28 45.15 45.15 46.77 39.82 51.47 24.70 1920 85 54.60 54.60 54.93 54.03 59.66 39.09 51.54 51.54 51.63 51.62 55.94 37.52 48.28 48.28 48.26 48.26 51.90 35.98 1920 90 57.93 57.93 57.89 57.89 60.25 50.33 54.77 54.77 54.71 54.71 56.53 49.14 51.48 51.48 51.43 51.43 52.60 47.64 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC 36.31 33.67 40.35 22.51 44.77 11.36 1440 75 1440 80 38.23 38.23 40.82 31.03 45.32 19.94 1440 85 40.97 40.97 41.47 39.94 45.70 28.44 1440 90 43.68 43.68 43.63 43.63 46.13 36.84 37.12 36.16 41.07 23.90 45.49 11.53 1600 75 1600 80 39.58 39.58 41.58 33.38 46.04 21.37 1600 85 42.39 42.39 42.46 42.41 46.45 30.42 1600 90 45.23 45.23 45.11 45.11 46.95 39.82 37.88 37.84 41.68 25.29 46.11 12.02 1760 75 1760 80 40.75 40.75 42.22 35.78 46.68 22.01 1760 85 43.69 43.69 43.63 43.63 47.05 32.37 1760 90 46.61 46.61 46.49 46.49 47.64 43.06 38.76 38.76 42.17 26.62 46.62 12.24 1920 75 1920 80 41.77 41.77 42.84 38.18 47.21 23.25 1920 85 44.78 44.78 44.79 44.79 47.67 34.47 1920 90 47.78 47.78 47.77 47.77 48.33 46.15 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity 54 RT-PRCO23-EN A TRANE Performance Data Table 27. Gross cooling capacities 4 tons high efficiency - three phase T/YHC048E,3,4 Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1440 75 46.71 38.85 51.74 27.73 57.13 16.82 43.61 37.29 48.41 26.50 53.54 14.96 40.36 35.67 44.85 24.15 49.73 13.25 1440 80 47.59 47.35 52.25 36.26 57.76 25.58 44.68 44.68 48.90 34.65 54.15 23.34 41.84 41.84 45.38 33.05 50.30 21.26 1440 85 50.50 50.50 52.85 44.98 58.26 33.44 47.72 47.72 49.53 43.27 54.64 31.95 44.77 44.77 46.01 41.82 50.80 30.34 1440 90 53.61 53.61 53.82 53.53 58.70 42.00 50.76 50.76 50.72 50.72 55.04 40.23 47.69 47.69 47.65 47.65 51.21 38.72 1600 75 47.84 41.58 52.84 29.51 58.21 16.60 44.65 39.99 49.39 27.30 54.53 15.03 41.27 38.28 45.75 25.88 50.63 13.43 1600 80 49.16 49.16 53.35 38.56 58.84 25.31 46.38 46.38 49.93 37.02 55.15 24.29 43.39 43.39 46.28 35.48 51.23 23.64 1600 85 52.42 52.42 54.04 48.25 59.40 35.49 49.49 49.49 50.64 46.68 55.66 33.77 46.44 46.44 47.07 45.28 51.69 32.28 1600 90 55.66 55.66 55.61 55.61 59.87 44.75 52.69 52.69 52.64 52.64 56.14 43.17 49.48 49.48 49.44 49.44 52.18 41.70 1760 75 48.78 44.24 53.71 30.62 59.15 16.79 45.51 42.63 50.19 28.83 55.38 15.23 42.13 40.85 46.45 27.27 51.40 13.65 1760 80 50.78 50.78 54.29 40.96 59.83 27.31 47.85 47.85 50.76 39.29 55.99 25.63 44.74 44.74 47.02 37.68 52.00 24.76 1760 85 54.11 54.11 55.11 51.57 60.33 37.49 51.12 51.12 51.70 50.06 56.53 35.92 47.90 47.90 48.04 47.80 52.47 34.31 1760 90 57.46 57.46 57.42 57.42 60.91 47.89 54.28 54.28 54.24 54.24 57.06 46.26 51.13 51.13 51.07 51.07 53.02 44.70 1920 75 49.57 46.91 54.49 31.84 59.96 16.95 46.34 45.03 50.91 30.19 56.11 15.50 42.85 42.61 47.08 28.63 52.03 13.75 1920 80 52.16 52.16 55.09 43.23 60.62 27.45 49.16 49.16 51.49 41.58 56.84 26.83 45.99 45.99 47.75 40.07 52.64 25.44 1920 85 55.60 55.60 56.10 54.73 61.16 39.54 52.52 52.52 52.67 52.46 57.25 37.89 49.18 49.18 49.16 49.16 53.11 36.31 1920 90 59.08 59.08 59.03 59.03 61.77 50.65 55.87 55.87 55.83 55.83 57.93 49.34 52.46 52.46 52.39 52.39 53.81 47.85 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC 36.86 34.00 41.06 22.65 45.66 11.65 1440 75 1440 80 38.74 38.74 41.56 31.33 46.24 19.65 1440 85 41.58 41.58 42.21 40.24 46.65 28.73 1440 90 44.41 44.41 44.31 44.31 47.05 37.10 37.73 36.56 41.84 24.10 46.44 11.79 1600 75 1600 80 40.16 40.16 42.37 33.65 47.02 21.84 1600 85 43.08 43.08 43.26 43.03 47.46 30.66 1600 90 46.01 46.01 45.97 45.97 47.92 39.96 38.50 38.36 42.48 25.56 47.09 11.97 1760 75 1760 80 41.39 41.39 43.06 36.07 47.68 22.17 1760 85 44.41 44.41 44.38 44.38 48.08 32.71 1760 90 47.44 47.44 47.38 47.38 48.65 43.22 39.34 39.34 43.00 26.92 47.65 12.48 1920 75 1920 80 42.46 42.46 43.68 38.44 48.22 23.54 1920 85 45.61 45.61 45.54 45.54 48.73 34.74 1920 90 48.69 48.69 48.64 48.64 49.43 46.51 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity RT-PRCO23-EN 55 M TRAME WF Performance Data Table 28. Gross cooling capacities 5 tons high efficiency - three phase T/YHC060E1 Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1800 75 58.30 49.11 64.82 36.01 71.80 22.38 54.69 47.20 60.92 34.31 67.62 21.26 50.77 45.18 56.61 31.89 62.96 17.81 1800 80 59.42 59.42 65.25 46.53 72.33 32.77 56.25 56.25 61.31 44.31 68.14 31.10 52.79 52.79 57.05 42.23 63.55 29.03 1800 85 63.16 63.16 65.74 56.78 72.63 43.30 59.93 59.93 61.85 54.88 68.47 41.26 56.37 56.37 57.58 52.91 63.89 39.18 1800 90 66.88 66.88 66.84 66.84 73.03 53.49 63.61 63.61 63.54 63.54 68.85 51.44 60.00 60.00 59.94 59.94 64.23 49.53 2000 75 59.61 52.43 66.05 37.54 73.14 22.70 55.88 50.55 62.04 35.65 68.78 20.78 51.79 48.42 57.62 33.57 63.96 19.43 2000 80 61.61 61.61 66.59 48.99 73.65 34.02 58.33 58.33 62.49 47.13 69.30 32.43 54.68 54.68 58.13 45.12 64.55 30.41 2000 85 65.50 65.50 67.13 60.90 73.98 46.03 62.15 62.15 63.13 58.96 69.71 43.84 58.48 58.48 58.80 57.04 64.92 41.61 2000 90 69.44 69.44 69.35 69.35 74.37 57.11 65.99 65.99 65.92 65.92 70.11 55.11 62.24 62.24 62.19 62.19 65.36 53.13 2200 75 60.71 55.72 67.10 38.84 74.13 22.74 56.94 53.79 63.01 37.68 69.76 21.05 52.80 51.75 58.50 35.12 64.95 19.16 2200 80 63.54 63.54 67.65 51.87 74.78 35.88 60.12 60.12 63.51 49.97 70.37 33.82 56.41 56.41 59.03 47.98 65.47 31.79 2200 85 67.60 67.60 68.37 64.96 75.12 47.62 64.14 64.14 64.38 63.17 70.69 46.27 60.27 60.27 60.21 60.21 65.85 44.05 2200 90 71.64 71.64 71.65 71.65 75.57 60.68 68.14 68.14 68.06 68.06 71.11 58.71 64.16 64.16 64.11 64.11 66.37 56.96 2400 75 61.71 58.91 67.98 41.14 75.01 23.72 57.92 57.05 63.81 39.16 70.61 21.34 53.87 53.87 59.23 36.47 65.63 20.09 2400 80 65.23 65.23 68.54 54.70 75.72 37.17 61.72 61.72 64.41 52.84 71.13 35.16 57.90 57.90 59.90 50.86 66.24 33.11 2400 85 69.37 69.37 69.63 69.09 76.08 50.15 65.90 65.90 65.83 65.83 71.63 48.28 61.88 61.88 61.86 61.86 66.66 46.63 2400 90 73.64 73.64 73.58 73.58 76.59 64.31 70.00 70.00 69.93 69.93 72.17 62.57 65.92 65.92 65.86 65.86 67.26 60.67 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC 46.38 43.01 51.90 29.75 57.98 17.23 1800 75 1800 80 48.96 48.96 52.35 40.09 58.46 26.96 1800 85 52.46 52.46 53.01 50.89 58.88 37.16 1800 90 56.01 56.01 55.96 55.96 59.24 47.44 47.42 46.28 52.81 30.85 58.89 16.74 2000 75 2000 80 50.75 50.75 53.34 43.01 59.42 28.29 2000 85 54.38 54.38 54.38 54.38 59.85 39.61 2000 90 58.05 58.05 58.02 58.02 60.23 51.15 48.52 48.52 53.60 33.16 59.71 17.30 2200 75 2200 80 52.27 52.27 54.18 45.81 60.26 29.65 2200 85 56.09 56.09 56.05 56.05 60.64 42.15 2200 90 59.85 59.85 59.80 59.80 61.20 54.93 49.75 49.75 54.27 34.65 60.39 17.26 2400 75 2400 80 53.58 53.58 54.88 48.84 60.95 30.94 2400 85 57.52 57.52 57.45 57.45 61.24 44.63 2400 90 61.46 61.46 61.39 61.39 62.12 58.89 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity 56 RT-PRCO23-EN A TRANE Performance Data Table 29. Gross cooling capacities 5 tons high efficiency - three phase T/YHC060E3,4 Ambient Temperature 85 95 105 Air Ent Entering Wet Bulb Flow DB 61 67 73 61 67 73 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC 1800 75 59.56 49.58 65.99 35.89 72.88 22.54 55.71 47.49 61.89 34.49 68.49 20.74 51.74 45.43 57.53 32.41 63.82 18.60 1800 80 60.46 60.32 66.42 46.59 73.49 33.29 57.05 57.05 62.32 44.54 69.01 31.17 53.52 53.52 57.96 42.65 64.32 29.29 1800 85 64.08 64.08 66.89 57.00 73.87 43.37 60.69 60.69 62.82 55.07 69.44 41.48 57.08 57.08 58.52 53.07 64.69 39.39 1800 90 67.81 67.81 67.85 67.72 74.21 53.63 64.34 64.34 64.27 64.27 69.76 51.42 60.65 60.65 60.60 60.60 65.06 49.57 2000 75 60.83 52.78 67.28 37.85 74.20 22.90 56.93 50.81 63.03 35.70 69.61 21.19 52.84 48.74 58.59 33.81 64.89 18.98 2000 80 62.57 62.57 67.73 49.35 74.82 34.58 59.12 59.12 63.49 47.33 70.20 32.64 55.45 55.45 59.03 45.41 65.39 30.54 2000 85 66.45 66.45 68.38 61.14 75.15 45.81 62.92 62.92 64.16 59.19 70.62 43.78 59.18 59.18 59.74 57.16 65.78 41.83 2000 90 70.36 70.36 70.32 70.32 75.55 57.08 66.77 66.77 66.69 66.69 71.02 55.15 62.89 62.89 62.83 62.83 66.22 53.24 2200 75 61.94 56.03 68.33 39.54 75.28 23.26 57.96 54.06 64.01 37.90 70.63 20.97 53.76 52.00 59.41 35.31 65.76 19.07 2200 80 64.51 64.51 68.83 52.16 75.90 35.93 60.94 60.94 64.56 50.21 71.23 33.87 57.18 57.18 59.98 48.17 66.33 31.93 2200 85 68.48 68.48 69.55 65.16 76.27 48.35 64.88 64.88 65.34 63.36 71.68 46.32 61.01 61.01 60.99 60.92 66.71 44.27 2200 90 72.56 72.56 72.60 72.60 76.79 60.75 68.86 68.86 68.80 68.80 72.08 58.83 64.84 64.84 64.79 64.79 67.17 56.86 2400 75 62.94 59.31 69.23 41.24 76.12 22.87 58.90 57.26 64.84 39.07 71.44 21.67 54.79 54.68 60.19 36.97 66.53 19.50 2400 80 66.23 66.23 69.85 55.03 76.88 37.13 62.54 62.54 65.44 52.99 72.05 35.12 58.63 58.63 60.76 51.02 67.10 33.05 2400 85 70.45 70.45 70.82 69.31 77.29 51.04 66.65 66.65 66.65 66.62 72.52 48.51 62.62 62.62 62.52 62.52 67.61 46.75 2400 90 74.58 74.58 74.53 74.53 77.77 64.34 70.73 70.73 70.66 70.66 72.91 62.47 66.57 66.57 66.53 66.53 68.23 60.73 Ambient Temperature 115 Entering Wet Bulb Air Ent Flow DB 61 67 73 cfm (F) MBh SHC MBh SHC MBh SHC 47.43 43.28 52.93 30.03 58.87 16.71 1800 75 1800 80 49.78 49.78 53.40 40.31 59.38 27.15 1800 85 53.27 53.27 53.96 51.01 59.77 37.20 1800 90 56.69 56.69 56.65 56.65 60.12 47.72 48.47 46.53 53.82 31.65 59.84 16.97 2000 75 2000 80 51.57 51.57 54.36 43.23 60.35 28.45 2000 85 55.17 55.17 55.30 55.11 60.73 40.17 2000 90 58.74 58.74 58.72 58.72 61.22 51.25 49.42 49.35 54.60 33.15 60.62 17.27 2200 75 2200 80 53.11 53.11 55.16 45.98 61.13 29.79 2200 85 56.81 56.81 56.76 56.76 61.58 42.48 2200 90 60.60 60.60 60.52 60.52 62.10 55.08 50.67 50.67 55.27 34.98 61.27 17.50 2400 75 2400 80 54.47 54.47 55.91 49.04 61.81 31.05 2400 85 58.32 58.32 58.24 58.24 62.28 44.92 2400 90 62.17 62.17 62.12 62.12 62.89 58.75 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat. For indoor fan heat formula, refer to appropriate airflow table notes. 2. MBh = Total Gross Capacity 3. SHC = Sensible Heat Capacity RT-PRCO23-EN 57 0 TRINE" Direct Drive - Evaporator Fan Performance Table 30. Multispeed direct drive evaporator fan performance 3 - 5 tons - standard efficiency - no electric heat TSC036, 048, 060E1 External Static Pressure (Inches of Water & Motor Power B p Standard Low Standard High Rated Speed Mid Speed Speed High Speed Unit Model Speed Set 1 Speed Set 2 Speed Set 3 Speed Set 4 Speed Set 5 Tons Number cfm ESP rpm bhp ESP rpm p ESP rpm bhp ESP rpm bhp ESP rpm bhp 3 960 0.45 715 0.21 0.74 851 0.31 0.92 929 0.38 1.07 993 0.44 1.25 1053 0.52 3 1020 0.39 695 0.20 0.66 826 0.30 0.84 905 0.37 0.99 969 0.43 1.17 1030 0.50 3 1080 0.33 675 0.20 0.59 800 0.29 0.77 880 0.36 0.91 945 0.42 1.08 1007 0.49 3 TSC036E1 1140 0.27 654 0.19 0.51 774 0.28 0.69 855 0.35 0.83 921 0.41 1.00 985 0.48 3 Downflow 1200 0.21 634 0.18 0.43 749 0.27 0.61 831 0.34 0.75 898 0.40 0.91 962 0.47 3 Airflow 1260 0.15 614 0.18 0.35 723 0.26 0.53 806 0.33 0.67 874 0.39 0.83 939 0.46 3 1320 0.09 593 0.17 0.28 697 0.25 0.45 782 0.32 0.59 850 0.38 0.74 916 0.45 3 1380 0.03 573 0.17 0.20 671 0.24 0.37 757 0.31 0.51 826 0.37 0.66 893 0.44 3 1440 - - - 0.12 646 0.23 0.29 732 0.30 0.43 802 0.36 0.57 871 0.43 3 960 0.45 711 0.21 0.70 835 0.30 0.89 913 0.37 1.04 978 0.44 1.21 1037 0.51 3 1020 0.39 689 0.20 0.63 811 0.29 0.81 890 0.36 0.96 957 0.43 1.13 1016 0.50 3 1080 0.32 667 0.19 0.56 787 0.28 0.73 868 0.35 0.88 935 0.42 1.04 996 0.49 3 TSC036E1 1140 0.26 644 0.19 0.48 763 0.28 0.65 845 0.34 0.80 913 0.41 0.95 975 0.48 3 Horizontal 1200 0.20 622 0.18 0.41 739 0.27 0.57 823 0.33 0.72 892 0.40 0.87 955 0.47 3 Airflow 1260 0.13 599 0.17 0.33 715 0.26 0.50 800 0.32 0.64 870 0.39 0.78 934 0.46 3 1320 0.07 577 0.17 0.26 691 0.25 0.42 777 0.32 0.56 848 0.38 0.69 913 0.45 3 1380 0.01 555 0.16 0.18 667 0.24 0.34 755 0.31 0.48 826 0.37 0.61 893 0.44 3 1440 - - - 0.11 642 0.23 0.26 732 0.30 0.40 805 0.36 0.52 872 0.43 4 1280 0.60 865 0.36 0.84 977 0.47 1.02 1044 0.55 1.17 1090 0.63 - - - 4 1360 0.48 833 0.35 0.72 944 0.45 0.90 1012 0.54 1.04 1062 0.61 - - - 4 1440 0.37 802 0.34 0.60 912 0.44 0.77 980 0.52 0.92 1033 0.60 - - - 4 TSC048E1 1520 0.25 770 0.32 0.48 879 0.42 0.65 948 0.50 0.80 1005 0.58 1.06 1100 0.69 4 Downflow 1600 0.14 739 0.31 0.36 846 0.41 0.52 915 0.49 0.68 976 0.56 0.92 1069 0.67 4 Airflow 1680 0.02 707 0.30 0.24 814 0.39 0.39 883 0.47 0.56 948 0.55 0.78 1038 0.65 4 1760 - - - 0.13 781 0.38 0.27 851 0.45 0.43 920 0.53 0.64 1006 0.63 4 1840 - - - 0.01 748 0.36 0.14 819 0.43 0.31 891 0.52 0.50 975 0.62 4 1920 - - - 0.02 787 0.42 0.19 863 0.50 0.37 944 0.60 4 1280 0.61 864 0.36 0.84 967 0.47 1.00 1038 0.55 1.16 1115 0.65 - - - 4 1360 0.51 831 0.35 0.73 935 0.45 0.88 1006 0.53 1.05 1084 0.63 - - - 4 1440 0.40 798 0.33 0.62 904 0.44 0.77 974 0.52 0.94 1052 0.61 1.10 1114 0.70 4 TSC048E1 1520 0.30 766 0.32 0.51 873 0.42 0.66 943 0.50 0.82 1020 0.59 0.99 1084 0.68 4 Horizontal 1600 0.19 733 0.31 0.40 842 0.41 0.55 911 0.48 0.71 989 0.57 0.87 1054 0.66 4 Airflow 1680 0.09 701 0.29 0.29 810 0.39 0.44 879 0.47 0.60 957 0.55 0.75 1023 0.65 4 1760 - - - 0.18 779 0.38 0.32 848 0.45 0.48 925 0.54 0.64 993 0.63 4 1840 - - - 0.08 748 0.36 0.21 816 0.43 0.37 893 0.52 0.52 963 0.61 4 1920 - - - - - - 0.10 784 0.42 0.26 861 0.50 0.40 932 0.59 5 1600 0.75 1006 0.60 0.91 1065 0.69 - - - - - - - - - 5 1700 0.60 969 0.58 0.75 1024 0.66 0.96 1101 0.77 - - - - - - 5 1800 0.45 933 0.56 0.58 982 0.63 0.78 1059 0.74 - - - - - - 5 TSC060E1 1900 0.30 896 0.54 0.42 941 0.61 0.61 1017 0.71 0.82 1105 0.83 - - - 5 Downflow 2000 0.14 860 0.52 0.25 899 0.58 0.43 975 0.68 0.64 1062 0.80 0.70 1083 0.85 5 Airflow 2100 0.00 826 0.50 0.09 858 0.55 0.25 933 0.65 0.46 1019 0.77 0.54 1045 0.82 5 2200 - - - - - - 0.08 891 0.62 0.28 975 0.74 0.37 1007 0.79 5 2300 - - - - - - - - - 0.10 932 0.70 0.20 969 0.76 5 2400 - - - - - - 0.03 931 0.73 5 1600 0.73 1003 0.60 0.90 1075 0.69 - - - - - - - - - 5 1700 0.60 968 0.58 0.74 1034 0.67 0.89 1104 0.77 - - - - - - 5 1800 0.46 934 0.56 0.59 993 0.64 0.74 1064 0.74 - - - - - - 5 TSC060E1 1900 0.33 899 0.54 0.44 952 0.62 0.59 1023 0.71 0.75 1095 0.83 - - - 5 Horizontal 2000 0.19 864 0.52 0.28 911 0.59 0.43 983 0.69 0.60 1053 0.79 0.69 1090 0.86 5 Airflow 2100 0.05 829 0.50 0.13 870 0.56 0.28 942 0.66 0.44 1012 0.76 0.53 1051 0.83 5 2200 - - - 0.00 837 0.54 0.13 902 0.63 0.28 971 0.73 0.37 1012 0.80 5 2300 - - - - - - 0.00 868 0.61 0.12 930 0.70 0.21 972 0.77 5 2400 - - - - - - - - - 0.00 897 0.68 0.06 933 0.74 For 036 Models, fan motor heat MB = 2.72 x Fan Bhp + 0.16. For 048 & 060 Models, fan motor heat MB = 2.87 x Fan Bhp + 0.15. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Data includes pressure drop due to wet coil and filters. 58 RT-PRCO23-EN A TRANE Direct Drive - Evaporator Fan Performance Table 31. Multispeed direct drive evaporator fan performance 3 - 5 tons -standard efficiency - low & medium gas heat TSC036, 048, 060EII External Static Pressure (Inches of Water) & Motor Power (Bhp)(a) Standard Low Standard High Rated Speed Mid Speed Speed High Speed Unit Model Speed Set 1 Speed Set 2 Speed Set 3 Speed Set 4 Speed Set 5 Tons Number cfm ESP rpm bhp ESP rpm bhp ESP rpm bhp ESP rpm bhp ESP rpm p 3 960 0.43 718 0.19 0.64 825 0.27 0.88 923 0.35 1.12 1017 0.46 1.28 1074 0.52 3 1020 0.37 696 0.18 0.57 800 0.26 0.80 900 0.35 1.04 997 0.45 1.20 1053 0.51 3 1080 0.30 675 0.18 0.49 775 0.26 0.72 877 0.34 0.96 977 0.44 1.11 1033 0.50 3 YSC036E1**L,M 1140 0.24 654 0.17 0.42 749 0.25 0.64 854 0.33 0.87 957 0.43 1.03 1013 0.49 3 Downflow 1200 0.18 633 0.17 0.34 724 0.24 0.56 832 0.32 0.79 938 0.42 0.94 992 0.48 3 Airflow 1260 0.11 612 0.16 0.26 698 0.23 0.48 809 0.31 0.71 918 0.41 0.86 972 0.47 3 1320 0.05 590 0.16 0.19 673 0.22 0.39 786 0.30 0.63 898 0.40 0.77 951 0.46 3 1380 - - - 0.11 647 0.21 0.31 763 0.29 0.55 878 0.39 0.68 931 0.45 3 1440 - - - 0.03 622 0.21 0.23 740 0.28 0.47 859 0.38 0.60 910 0.44 3 960 0.42 715 0.19 0.67 842 0.28 0.90 937 0.36 1.15 1037 0.46 1.25 1062 0.51 3 1020 0.37 695 0.18 0.61 819 0.27 0.83 916 0.35 1.07 1014 0.45 1.18 1047 0.50 3 1080 0.31 675 0.18 0.54 796 0.26 0.75 895 0.34 0.99 992 0.44 1.11 1032 0.50 3 YSC036El**L,M 1140 0.26 654 0.17 0.47 772 0.26 0.68 874 0.34 0.91 970 0.43 1.04 1017 0.49 3 Horizontal 1200 0.20 634 0.17 0.41 749 0.25 0.61 853 0.33 0.83 948 0.42 0.97 1002 0.48 3 Airflow 1260 0.14 614 0.16 0.34 725 0.24 0.54 832 0.32 0.75 926 0.41 0.90 987 0.48 3 1320 0.09 594 0.16 0.27 702 0.23 0.47 811 0.31 0.67 903 0.40 0.83 972 0.47 3 1380 0.03 574 0.15 0.20 678 0.22 0.40 789 0.30 0.59 881 0.39 0.76 957 0.46 3 1440 - - - 0.14 654 0.22 0.33 768 0.29 0.51 859 0.38 0.69 942 0.45 4 1280 0.71 933 0.42 0.89 1003 0.49 1.11 1094 0.59 - - - - - - 4 1360 0.59 903 0.41 0.76 973 0.48 0.97 1061 0.57 1.14 1116 0.64 - - - 4 1440 0.47 874 0.39 0.63 943 0.46 0.84 1027 0.56 1.00 1085 0.62 - - - 4 YSC048E1**L,M 1520 0.34 845 0.38 0.50 913 0.45 0.70 993 0.54 0.86 1053 0.61 1.05 1122 0.70 4 Downflow 1600 0.22 815 0.37 0.38 883 0.43 0.56 959 0.52 0.72 1021 0.59 0.90 1089 0.68 4 Airflow 1680 0.10 786 0.36 0.25 852 0.42 0.42 926 0.50 0.58 990 0.57 0.76 1057 0.66 4 1760 - - - 0.12 822 0.41 0.28 892 0.48 0.45 958 0.55 0.61 1024 0.64 4 1840 - - - - - - 0.15 858 0.46 0.31 926 0.53 0.47 992 0.62 4 1920 - - - - - - 0.01 824 0.45 0.17 895 0.51 0.32 960 0.60 4 1280 0.66 894 0.40 0.81 967 0.48 1.01 1051 0.57 1.14 1101 0.63 - - - 4 1360 0.54 863 0.39 0.70 935 0.46 0.88 1016 0.55 1.01 1069 0.61 - - - 4 1440 0.43 831 0.38 0.58 904 0.45 0.76 982 0.53 0.89 1037 0.60 1.05 1101 0.69 4 YSC048E1**L,M 1520 0.31 799 0.36 0.47 872 0.43 0.63 947 0.51 0.77 1006 0.58 0.93 1069 0.67 4 Horizontal 1600 0.20 768 0.35 0.35 840 0.41 0.51 912 0.49 0.64 974 0.56 0.80 1037 0.65 4 Airflow 1680 0.08 736 0.33 0.24 809 0.40 0.38 877 0.47 0.52 942 0.54 0.67 1005 0.63 4 1760 - - - 0.12 777 0.38 0.26 842 0.46 0.40 911 0.52 0.55 973 0.61 4 1840 - - - 0.01 745 0.37 0.13 807 0.44 0.28 879 0.51 0.42 941 0.59 4 1920 - - - - - - 0.00 773 0.42 0.15 847 0.49 0.29 909 0.57 5 1600 0.97 1110 0.71 - - - - - - - - - - - - 5 1700 0.79 1068 0.68 0.91 1120 0.77 - - - - - - - - - 5 1800 0.60 1026 0.66 0.73 1079 0.74 - - - - - - - - - 5 YSC060E1**L,M 1900 0.42 984 0.63 0.54 1038 0.71 0.69 1093 0.78 - - - - - - 5 Downflow 2000 0.24 942 0.60 0.36 997 0.68 0.50 1050 0.74 0.60 1079 0.82 - - - 5 Airflow 2100 0.06 900 0.57 0.18 956 0.65 0.31 1006 0.71 0.42 1040 0.79 0.52 1078 0.86 5 2200 - - - 0.00 916 0.63 0.12 963 0.68 0.24 1001 0.76 0.32 1036 0.83 5 2300 - - - - - - 0.00 936 0.66 0.05 962 0.73 0.13 994 0.79 5 2400 - - - - - - - - - - - - 0.00 965 0.77 5 1600 0.83 1054 0.67 - - - - - - - - - - - - 5 1700 0.67 1013 0.65 0.83 1084 0.74 - - - - - - - - - 5 1800 0.51 971 0.62 0.65 1039 0.71 0.75 1075 0.76 - - - - - - 5 YSC060E1**L,M 1900 0.36 930 0.59 0.48 995 0.68 0.57 1031 0.73 0.72 1086 0.82 - - - 5 Horizontal 2000 0.20 888 0.57 0.30 951 0.65 0.39 987 0.70 0.54 1045 0.79 0.67 1092 0.87 5 Airflow 2100 0.04 847 0.54 0.12 907 0.62 0.21 942 0.67 0.36 1004 0.76 0.48 1051 0.84 5 2200 - - - 0.00 877 0.60 0.02 898 0.64 0.17 963 0.73 0.29 1010 0.81 5 2300 - - - - - - - - - 0.00 924 0.70 0.10 968 0.77 5 2400 - - - - - - - - - - - - 0.00 946 0.76 For 036 Models, fan motor heat (MBh) = 2.72 x Fan Bhp + 0.16. For 048 & 060 Models, fan motor heat (MBh) = 2.87 x Fan Bhp + 0.15. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Data includes pressure drop due to wet coil and filters. RT-PRCO23-EN 59 TRAWE WF Direct Drive - Evaporator Fan Performance Table 32. Multispeed direct drive evaporator fan performance 3 - 5 tons - standard efficiency - high heat YSC036, 048, 060E1 External Static Pressure (Inches of Water) & Motor Power (Bhp)(a) Standard Low Standard High Rated Speed Mid Speed Speed High Speed Unit Model Speed Set 1 Speed Set 2 Speed Set 3 Speed Set 4 Speed Set 5 Tons Number cfm ESP rpm bhp ESP rpm bhp ESP rpm bhp ESP rpm bhp ESP rpm bhp 3 960 0.43 718 0.19 0.64 825 0.26 0.88 923 0.34 1.12 1017 0.44 1.28 1074 0.51 3 1020 0.37 696 0.19 0.57 800 0.26 0.80 900 0.34 1.04 997 0.43 1.20 1053 0.50 3 1080 0.30 675 0.18 0.49 775 0.25 0.72 877 0.33 0.96 977 0.42 1.11 1033 0.49 3 YSC036E1**H 1140 0.24 654 0.18 0.42 749 0.24 0.64 854 0.32 0.87 957 0.42 1.03 1013 0.48 3 Downflow 1200 0.18 633 0.17 0.34 724 0.23 0.56 832 0.31 0.79 938 0.41 0.94 992 0.47 3 Airflow 1260 0.11 612 0.16 0.26 698 0.22 0.48 809 0.30 0.71 918 0.40 0.86 972 0.46 3 1320 0.05 590 0.16 0.19 673 0.21 0.39 786 0.29 0.63 898 0.39 0.77 951 0.45 3 1380 - - - 0.11 647 0.21 0.31 763 0.28 0.55 878 0.38 0.68 931 0.44 3 1440 - - - 0.03 622 0.20 0.23 740 0.28 0.47 859 0.37 0.60 910 0.43 3 960 0.44 732 0.20 0.65 836 0.27 0.87 935 0.35 1.12 1033 0.45 1.25 1078 0.51 3 1020 0.37 708 0.19 0.58 811 0.26 0.80 911 0.34 1.03 1010 0.44 1.17 1059 0.50 3 1080 0.31 684 0.18 0.51 787 0.25 0.72 886 0.33 0.95 987 0.43 1.09 1040 0.49 3 YSC036E1**H 1140 0.24 660 0.18 0.43 762 0.24 0.64 862 0.32 0.87 964 0.42 1.01 1021 0.48 3 Horizontal 1200 0.18 636 0.17 0.36 737 0.24 0.56 838 0.31 0.79 941 0.41 0.93 1002 0.47 3 Airflow 1260 0.11 612 0.16 0.29 712 0.23 0.48 814 0.30 0.70 918 0.40 0.85 983 0.47 3 1320 0.05 588 0.16 0.21 688 0.22 0.40 789 0.29 0.62 895 0.39 0.77 964 0.46 3 1380 - - - 0.14 663 0.21 0.32 765 0.28 0.54 872 0.38 0.69 945 0.45 3 1440 - - - 0.07 638 0.20 0.24 741 0.28 0.45 849 0.37 0.61 926 0.44 4 1280 0.73 951 0.44 0.93 1025 0.52 1.10 1084 0.60 - - - - - - 4 1360 0.61 917 0.42 0.80 991 0.50 0.96 1051 0.58 1.14 1116 0.67 - - - 4 1440 0.48 883 0.41 0.66 957 0.49 0.82 1019 0.56 1.00 1085 0.65 - - - 4 YSC048E1**H 1520 0.35 849 0.39 0.53 923 0.47 0.69 986 0.55 0.86 1053 0.63 - - - 4 Downflow 1600 0.23 816 0.38 0.39 888 0.45 0.55 954 0.53 0.72 1021 0.61 0.91 1093 0.71 4 Airflow 1680 0.10 782 0.36 0.26 854 0.43 0.42 922 0.51 0.58 990 0.59 0.76 1060 0.68 4 1760 - - - 0.12 820 0.42 0.28 889 0.49 0.45 958 0.57 0.62 1028 0.66 4 1840 - - - - - - 0.14 857 0.47 0.31 926 0.55 0.47 995 0.64 4 1920 - - - - - - 0.01 824 0.46 0.17 895 0.53 0.32 962 0.62 4 1280 0.69 933 0.43 0.86 1005 0.51 1.04 1075 0.59 1.18 1124 0.67 - - - 4 1360 0.57 899 0.42 0.74 971 0.49 0.91 1041 0.57 1.05 1091 0.65 - - - 4 1440 0.45 865 0.40 0.61 938 0.48 0.78 1006 0.56 0.92 1059 0.63 - - - 4 YSC048E1**H 1520 0.33 831 0.38 0.49 904 0.46 0.65 972 0.54 0.79 1026 0.61 0.95 1091 0.70 4 Horizontal 1600 0.21 797 0.37 0.36 870 0.44 0.52 938 0.52 0.65 993 0.59 0.82 1060 0.68 4 Airflow 1680 0.08 764 0.35 0.24 837 0.42 0.38 904 0.50 0.52 961 0.57 0.69 1030 0.66 4 1760 - - - 0.11 803 0.41 0.25 870 0.48 0.39 928 0.55 0.55 999 0.65 4 1840 - - - - - - 0.12 835 0.46 0.26 896 0.54 0.42 968 0.63 4 1920 - - - - - - - - - 0.12 863 0.52 0.29 937 0.61 5 1600 0.97 1110 0.73 - - - - - - - - - - - - 5 1700 0.79 1068 0.70 0.91 1120 0.78 - - - - - - - - - 5 1800 0.60 1026 0.67 0.73 1079 0.75 - - - - - - - - - 5 YSC060E1**H 1900 0.42 984 0.65 0.54 1038 0.72 0.69 1093 0.81 - - - - - - 5 Downflow 2000 0.24 942 0.62 0.36 997 0.69 0.50 1050 0.78 0.60 1079 0.84 - - - 5 Airflow 2100 0.06 900 0.59 0.18 956 0.66 0.31 1006 0.74 0.42 1040 0.81 0.52 1078 0.86 5 2200 - - - 0.00 916 0.64 0.12 963 0.71 0.24 1001 0.78 0.32 1036 0.83 5 2300 - - - - - - 0.00 936 0.69 0.05 962 0.75 0.13 994 0.79 5 2400 - - - - - - - - - - - - 0.00 965 0.77 5 1600 0.95 1110 0.73 - - - - - - - - - - - - 5 1700 0.76 1064 0.70 0.87 1110 0.77 - - - - - - - - - 5 1800 0.58 1019 0.67 0.69 1067 0.74 - - - - - - - - - 5 YSC060E1**H 1900 0.40 973 0.64 0.51 1024 0.71 0.64 1075 0.79 - - - - - - 5 Horizontal 2000 0.21 927 0.61 0.32 982 0.68 0.45 1033 0.76 0.55 1069 0.83 0.64 1103 0.88 5 Airflow 2100 0.03 882 0.58 0.14 939 0.65 0.26 991 0.73 0.37 1029 0.80 0.45 1060 0.85 5 2200 - - - 0.00 907 0.63 0.08 949 0.70 0.18 989 0.77 0.26 1017 0.81 5 2300 - - - - - - - - - 0.00 949 0.74 0.07 975 0.78 5 2400 - - - - - - - - - - - - - - - For 036 Models, fan motor heat (MBh) = 2.72 x Fan Bhp + 0.16. For 048 & 060 Models, fan motor heat (MBh) = 2.87 x Fan Bhp + 0.15. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Data includes pressure drop due to wet coil and filters. 60 RT-PRCO23-EN A TRANE Direct Drive - Evaporator Fan Performance Table 33. Multispeed direct drive evaporator fan performance 3 - 5 tons - standard efficiency - WSC036, 048, 060E1 External Static Pressure (Inches of Water) & Motor Power (Bhp)(a) Standard Low Standard High Rated Speed Mid Speed Speed High Speed Unit Model Speed Set 1 Speed Set 2 Speed Set 3 Speed Set 4 Speed Set 5 Tons Number cfm ESP rpm bVp ESP rpm bhp ESP rpm bhp ESP rpm bhp ESP rpm bhp 3 960 0.43 707 0.21 0.70 843 0 38 0.88 919 0.38 1.02 979 0.36 1.15 1027 0.50 3 1020 0.37 687 0.20 0.62 818 0.37 0.80 896 0.37 0.94 956 0.35 1.07 1006 0.49 3 1080 0.31 668 0.19 0.55 792 0.36 0.73 872 0.36 0.87 933 0.34 0.99 985 0.48 3 WSC036E1 1140 0.25 648 0.19 0.47 766 0.35 0.65 849 0.35 0.79 911 0.33 0.91 964 0.47 3 Downflow 1200 0.19 628 0.18 0.39 740 0.34 0.57 826 0.34 0.71 888 0.32 0.83 943 0.46 3 Airflow 1260 0.13 609 0.18 0.31 715 0.32 0.50 803 0.33 0.63 866 0.32 0.75 922 0.45 3 1320 0.07 589 0.17 0.24 689 0.31 0.42 780 0.32 0.56 843 0.31 0.68 901 0.44 3 1380 0.01 569 0.17 0.16 663 0.30 0.34 757 0.31 0.48 820 0.30 0.60 880 0.43 3 1440 - - - 0.08 637 0.29 0.26 734 0.30 0.40 798 0.29 0.52 859 0.42 3 960 0.40 707 0.21 0.69 856 0.31 0.88 941 0.39 1.03 987 0.45 1.16 1034 0.50 3 1020 0.35 688 0.20 0.62 831 0.30 0.80 916 0.38 0.95 967 0.44 1.08 1011 0.49 3 1080 0.30 669 0.19 0.55 806 0.29 0.73 891 0.37 0.87 947 0.43 1.00 989 0.48 3 WSC036E1 1140 0.24 650 0.19 0.48 781 0.28 0.65 866 0.36 0.79 927 0.42 0.92 966 0.47 3 Horizontal 1200 0.19 631 0.18 0.41 756 0.28 0.58 841 0.35 0.71 906 0.41 0.84 943 0.46 3 Airflow 1260 0.14 612 0.18 0.34 731 0.27 0.50 816 0.34 0.63 886 0.40 0.76 920 0.45 3 1320 0.09 593 0.17 0.26 706 0.26 0.43 791 0.33 0.55 866 0.39 0.68 898 0.44 3 1380 0.04 574 0.17 0.19 681 0.25 0.35 766 0.32 0.47 846 0.38 0.60 875 0.43 3 1440 - - - 0.12 655 0.24 0.28 741 0.30 0.40 826 0.37 0.52 852 0.42 4 1280 0.60 865 0.36 0.84 977 0.47 1.02 1044 0.55 1.17 1090 0.6 - - - 4 1360 0.48 833 0.35 0.72 944 0.45 0.90 1012 0.54 1.04 1062 0.61 - - - 4 1440 0.37 802 0.34 0.60 912 0.44 0.77 980 0.52 0.92 1033 0.60 - - - 4 WSC048E1 1520 0.25 770 0.32 0.48 879 0.42 0.65 948 0.50 0.80 1005 0.58 1.06 1100 0.69 4 Downflow 1600 0.14 739 0.31 0.36 846 0.41 0.52 915 0.49 0.68 976 0.56 0.92 1069 0.67 4 Airflow 1680 0.02 707 0.30 0.24 814 0.39 0.39 883 0.47 0.56 948 0.55 0.78 1038 0.65 4 1760 - - - 0.13 781 0.38 0.27 851 0.45 0.43 920 0.53 0.64 1006 0.63 4 1840 - - - 0.01 748 0.36 0.14 819 0.43 0.31 891 0.52 0.50 975 0.62 4 1920 - - - - - - 0.02 787 0.42 0.19 863 0.50 0.37 944 0.60 4 1280 0.61 864 0.36 0.84 967 0.47 1.00 1038 0.55 1.16 1115 0.65 - - - 4 1360 0.51 831 0.35 0.73 935 0.45 0.88 1006 0.53 1.05 1084 0.63 - - - 4 1440 0.40 798 0.33 0.62 904 0.44 0.77 974 0.52 0.94 1052 0.61 1.10 1114 0.70 4 WSC048E1 1520 0.30 766 0.32 0.51 873 0.42 0.66 943 0.50 0.82 1020 0.59 0.99 1084 0.68 4 Horizontal 1600 0.19 733 0.31 0.40 842 0.41 0.55 911 0.48 0.71 989 0.57 0.87 1054 0.66 4 Airflow 1680 0.09 701 0.29 0.29 810 0.39 0.44 879 0.47 0.60 957 0.55 0.75 1023 0.65 4 1760 - - - 0.18 779 0.38 0.32 848 0.45 0.48 925 0.54 0.64 993 0.63 4 1840 - - - 0.08 748 0.36 0.21 816 0.43 0.37 893 0.52 0.52 963 0.61 4 1920 - - - - - - 0.10 784 0.42 0.26 861 0.50 0.40 932 0.59 5 1600 0.83 888 0.49 0.95 948 0.56 1.19 1048 0.67 - - - - - - 5 1700 0.69 847 0.46 0.82 908 0.53 1.04 1004 0.64 1.33 1110 0.78 - - - 5 1800 0.56 806 0.44 0.69 867 0.51 0.90 959 0.62 1.18 1063 0.75 - - - 5 WSC060E1 1900 0.43 764 0.42 0.56 826 0.48 0.76 915 0.59 1.02 1016 0.71 - - - 5 Downflow 2000 0.30 723 0.40 0.43 785 0.46 0.62 870 0.56 0.87 969 0.68 1.18 1089 0.88 5 Airflow 2100 0.16 681 0.37 0.30 744 0.44 0.47 826 0.53 0.71 922 0.65 1.03 1044 0.84 5 2200 0.03 640 0.35 0.17 703 0.41 0.33 781 0.50 0.56 876 0.61 0.87 999 0.81 5 2300 - - - 0.04 663 0.39 0.19 737 0.47 0.41 829 0.58 0.72 954 0.77 5 2400 - - - - - - 0.05 693 0.44 0.25 782 0.55 0.56 909 0.73 5 1600 0.76 884 0.48 0.82 932 0.55 0.98 1022 0.66 1.13 1104 0.77 - - - 5 1700 0.63 842 0.46 0.69 893 0.52 0.85 981 0.63 1.00 1061 0.74 - - - 5 1800 0.50 801 0.44 0.57 854 0.50 0.72 941 0.60 0.87 1018 0.71 - - - 5 WSC060E1 1900 0.36 759 0.42 0.45 815 0.48 0.60 900 0.58 0.74 975 0.68 - - - 5 Horizontal 2000 0.23 718 0.39 0.32 776 0.46 0.47 859 0.55 0.61 932 0.65 0.87 1069 0.86 5 Airflow 2100 0.10 676 0.37 0.20 737 0.43 0.34 818 0.53 0.49 890 0.62 0.74 1025 0.83 5 2200 - - - 0.07 699 0.41 0.22 778 0.50 0.36 847 0.59 0.61 980 0.79 5 2300 - - - - - - 0.09 737 0.47 0.23 804 0.56 0.48 936 0.75 5 2400 - - - - - - - - - 0.10 761 0.53 0.35 892 0.72 For 036 Models, fan motor heat MB = 2.72 x Fan Bhp + 0.16. For 048 & 060 Models, fan motor heat MB = 2.87 x Fan Bhp + 0.15. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Data includes pressure drop due to wet coil and filters RT-PRCO23-EN 61 TRAWE WF Direct Drive - Evaporator Fan Performance Table 34. Multispeed direct drive evaporator fan performance 3 - 5 tons -high efficiency -no electric heat THC036, 048, 060E1,3,4 External Static Pressure (Inches of Water) & Motor Power (B p Standard Low Standard High Rated Speed Mid Speed Speed High Speed Unit Model Speed Set 1 Speed Set 2 Speed Set 3 Speed Set 4 Speed Set 5 Tons Number cfm ESP rpm bhp ESP rpm bhp ESP rpm bhp ESP rpm bhp ESP rpm bhp 3 960 0.45 715 0.21 0.74 851 0.31 0.92 929 0.38 1.07 993 0.44 1.25 1053 0.52 3 1020 0.39 695 0.20 0.66 826 0.30 0.84 905 0.37 0.99 969 0.43 1.17 1030 0.50 3 1080 0.33 675 0.20 0.59 800 0.29 0.77 880 0.36 0.91 945 0.42 1.08 1007 0.49 3 THC036E1,3,4 1140 0.27 654 0.19 0.51 774 0.28 0.69 855 0.35 0.83 921 0.41 1.00 985 0.48 3 Downflow 1200 0.21 634 0.18 0.43 749 0.27 0.61 831 0.34 0.75 898 0.40 0.91 962 0.47 3 Airflow 1260 0.15 614 0.18 0.35 723 0.26 0.53 806 0.33 0.67 874 0.39 0.83 939 0.46 3 1320 0.09 593 0.17 0.28 697 0.25 0.45 782 0.32 0.59 850 0.38 0.74 916 0.45 3 1380 0.03 573 0.17 0.20 671 0.24 0.37 757 0.31 0.51 826 0.37 0.66 893 0.44 3 1440 - - - 0.12 646 0.23 0.29 732 0.30 0.43 802 0.36 0.57 871 0.43 3 960 0.45 711 0.21 0.70 835 0.30 0.89 913 0.37 1.04 978 0.44 1.21 1037 0.51 3 1020 0.39 689 0.20 0.63 811 0.29 0.81 890 0.36 0.96 957 0.43 1.13 1016 0.50 3 1080 0.32 667 0.19 0.56 787 0.28 0.73 868 0.35 0.88 935 0.42 1.04 996 0.49 3 THC036E1,3,4 1140 0.26 644 0.19 0.48 763 0.28 0.65 845 0.34 0.80 913 0.41 0.95 975 0.48 3 Horizontal 1200 0.20 622 0.18 0.41 739 0.27 0.57 823 0.33 0.72 892 0.40 0.87 955 0.47 3 Airflow 1260 0.13 599 0.17 0.33 715 0.26 0.50 800 0.32 0.64 870 0.39 0.78 934 0.46 3 1320 0.07 577 0.17 0.26 691 0.25 0.42 777 0.32 0.56 848 0.38 0.69 913 0.45 3 1380 0.01 555 0.16 0.18 667 0.24 0.34 755 0.31 0.48 826 0.37 0.61 893 0.44 3 1440 - - - 0.11 642 0.23 0.26 732 0.30 0.40 805 0.36 0.52 872 0.43 4 1280 0.65 805 0.31 0.86 902 0.40 1.04 966 0.48 1.27 1042 0.58 - - - 4 1360 0.55 769 0.30 0.76 866 0.38 0.94 934 0.46 1.17 1010 0.56 1.43 1113 0.68 4 1440 0.46 733 0.28 0.66 830 0.37 0.84 902 0.44 1.06 977 0.54 1.31 1078 0.66 4 THC048E1,3,4 1520 0.36 696 0.27 0.56 794 0.35 0.74 869 0.43 0.95 944 0.52 1.20 1043 0.64 4 Downflow 1600 0.27 660 0.25 0.46 758 0.33 0.63 837 0.41 0.85 912 0.50 1.08 1009 0.62 4 Airflow 1680 0.17 624 0.24 0.36 722 0.32 0.53 805 0.40 0.74 879 0.49 0.97 974 0.60 4 1760 - - - 0.26 686 0.30 0.43 772 0.38 0.63 847 0.47 0.85 939 0.58 4 1840 - - - 0.16 650 0.29 0.33 740 0.36 0.53 814 0.45 0.74 905 0.55 4 1920 - - - 0.06 614 0.27 0.23 707 0.35 0.42 782 0.43 0.62 870 0.53 4 1280 0.56 795 0.31 0.77 880 0.39 0.95 967 0.48 1.16 1040 0.57 - - - 4 1360 0.48 760 0.29 0.67 847 0.37 0.86 935 0.46 1.06 1010 0.56 1.26 1105 0.68 4 1440 0.39 725 0.28 0.58 814 0.36 0.76 903 0.44 0.96 980 0.54 1.16 1075 0.66 4 THC048EI,3,4 1520 0.30 690 0.27 0.48 780 0.34 0.66 871 0.43 0.86 951 0.53 1.06 1045 0.64 4 Horizontal 1600 0.22 655 0.25 0.39 747 0.33 0.57 838 0.41 0.76 921 0.51 0.96 1016 0.62 4 Airflow 1680 0.13 619 0.24 0.30 714 0.31 0.47 806 0.40 0.66 891 0.49 0.86 986 0.60 4 1760 - - - 0.20 681 0.30 0.37 774 0.38 0.56 861 0.48 0.76 956 0.59 4 1840 - - - 0.11 647 0.29 0.28 742 0.37 0.46 831 0.46 0.66 926 0.57 4 1920 - - - 0.01 614 0.27 0.18 710 0.35 0.36 802 0.44 0.56 896 0.55 5 1600 0.82 918 0.50 1.04 1002 0.60 1.26 1087 0.72 - - - - - - 5 1700 0.67 873 0.47 0.89 957 0.58 1.11 1043 0.69 - - - - - - 5 1800 0.53 828 0.45 0.74 913 0.55 0.96 1000 0.66 1.16 1083 0.78 - - - 5 THC060E1,3,4 1900 0.39 782 0.42 0.59 869 0.52 0.82 957 0.63 1.02 1041 0.75 1.17 1099 0.85 5 Downflow 2000 0.25 737 0.40 0.45 824 0.50 0.67 914 0.60 0.87 999 0.72 1.02 1056 0.82 5 Airflow 2100 0.11 692 0.37 0.30 780 0.47 0.52 870 0.58 0.72 957 0.69 0.87 1014 0.78 5 2200 - - - 0.15 735 0.44 0.37 827 0.55 0.57 914 0.66 0.71 971 0.75 5 2300 - - - 0.00 691 0.42 0.22 784 0.52 0.42 872 0.63 0.56 929 0.72 5 2400 - - - - - - 0.07 741 0.49 0.27 830 0.60 0.41 886 0.68 5 1600 0.71 918 0.50 0.91 1001 0.60 1.09 1070 0.71 - - - - - - 5 1700 0.59 875 0.47 0.78 959 0.58 0.96 1029 0.68 1.11 1102 0.79 - - - 5 1800 0.46 832 0.45 0.65 916 0.55 0.82 987 0.65 0.97 1063 0.77 - - - 5 THC060E1,3,4 1900 0.33 788 0.43 0.51 874 0.53 0.68 945 0.62 0.84 1023 0.74 1.01 1093 0.85 5 Horizontal 2000 0.21 745 0.40 0.38 831 0.50 0.54 903 0.60 0.71 984 0.71 0.87 1052 0.81 5 Airflow 2100 0.08 701 0.38 0.25 788 0.47 0.41 861 0.57 0.57 944 0.68 0.73 1010 0.78 5 2200 - - - 0.12 746 0.45 0.27 819 0.54 0.44 904 0.65 0.59 968 0.75 5 2300 - - - - - - 0.13 778 0.51 0.31 865 0.62 0.45 926 0.72 5 2400 - - - - - - - - - 0.17 825 0.59 0.31 884 0.68 For 036 Models, fan motor heat MB = 2.72 x Fan Bhp + 0.16. For 048 & 060 Models, fan motor heat (MBh) = 2.87 x Fan Bhp + 0.15. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Data includes pressure drop due to wet coil and filters. 62 RT-PRCO23-EN A TRANE Direct Drive - Evaporator Fan Performance Table 35. Multispeed direct drive evaporator fan performance 3 - 5 tons -high efficiency - low & medium gas heat YHCO36,O48, O6OE1,3,4 External Static Pressure (Inches of Water & Motor Power B p Standard Low Standard High Rated Speed Mid Speed Speed High Speed Unit Model Speed Set 1 Speed Set 2 Speed Set 3 Speed Set 4 Speed Set 5 Tons Number cfm ESP rpm Rip ESP rpm bhp ESP rpm bhp ESP rpm bhp ESP rpm bhp 3 960 0.43 718 0.19 0.64 825 0.27 0.88 923 0.35 1.12 1017 0.46 1.28 1074 0.52 3 1020 0.37 696 0.18 0.57 800 0.26 0.80 900 0.35 1.04 997 0.45 1.20 1053 0.51 3 1080 0.30 675 0.18 0.49 775 0.26 0.72 877 0.34 0.96 977 0.44 1.11 1033 0.50 3 YHC036El,3,4**L,M 1140 0.24 654 0.17 0.42 749 0.25 0.64 854 0.33 0.87 957 0.43 1.03 1013 0.49 3 Downflow 1200 0.18 633 0.17 0.34 724 0.24 0.56 832 0.32 0.79 938 0.42 0.94 992 0.48 3 Airflow 1260 0.11 612 0.16 0.26 698 0.23 0.48 809 0.31 0.71 918 0.41 0.86 972 0.47 3 1320 0.05 590 0.16 0.19 673 0.22 0.39 786 0.30 0.63 898 0.40 0.77 951 0.46 3 1380 - - - 0.11 647 0.21 0.31 763 0.29 0.55 878 0.39 0.68 931 0.45 3 1440 - - - 0.03 622 0.21 0.23 740 0.28 0.47 859 0.38 0.60 910 0.44 3 960 0.42 715 0.19 0.67 842 0.28 0.90 937 0.36 1.15 1037 0.46 1.25 1062 0.51 3 1020 0.37 695 0.18 0.61 819 0.27 0.83 916 0.35 1.07 1014 0.45 1.18 1047 0.50 3 1080 0.31 675 0.18 0.54 796 0.26 0.75 895 0.34 0.99 992 0.44 1.11 1032 0.50 3 YHC036E1,3,4**L,M 1140 0.26 654 0.17 0.47 772 0.26 0.68 874 0.34 0.91 970 0.43 1.04 1017 0.49 3 Horizontal 1200 0.20 634 0.17 0.41 749 0.25 0.61 853 0.33 0.83 948 0.42 0.97 1002 0.48 3 Airflow 1260 0.14 614 0.16 0.34 725 0.24 0.54 832 0.32 0.75 926 0.41 0.90 987 0.48 3 1320 0.09 594 0.16 0.27 702 0.23 0.47 811 0.31 0.67 903 0.40 0.83 972 0.47 3 1380 0.03 574 0.15 0.20 678 0.22 0.40 789 0.30 0.59 881 0.39 0.76 957 0.46 3 1440 - - - 0.14 654 0.22 0.33 768 0.29 0.51 859 0.38 0.69 942 0.45 4 1280 0.69 820 0.33 0.88 903 0.41 1.07 969 0.49 1.07 969 0.49 1.27 1039 0.58 4 1360 0.59 785 0.32 0.78 869 0.40 0.96 936 0.48 0.96 936 0.48 1.16 1007 0.56 4 1440 0.49 750 0.30 0.68 835 0.38 0.86 903 0.46 0.86 903 0.46 1.05 976 0.55 4 YHC048El,3,4**L,M 1520 0.40 714 0.29 0.58 801 0.37 0.75 870 0.44 0.75 870 0.44 0.94 944 0.53 4 Downflow 1600 0.30 679 0.27 0.48 767 0.35 0.65 837 0.42 0.65 837 0.42 0.84 912 0.51 4 Airflow 1680 0.20 643 0.26 0.38 733 0.34 0.54 804 0.41 0.54 804 0.41 0.73 881 0.49 4 1760 0.10 608 0.25 0.28 699 0.32 0.44 771 0.39 0.44 771 0.39 0.62 849 0.48 4 1840 0.01 572 0.23 0.18 666 0.31 0.33 738 0.37 0.33 738 0.37 0.51 817 0.46 4 1920 - - - 0.08 632 0.29 0.23 705 0.36 0.23 705 0.36 0.41 786 0.44 4 1280 0.61 813 0.33 0.81 896 0.41 1.00 977 0.50 1.00 977 0.50 1.17 1044 0.58 4 1360 0.51 777 0.31 0.70 862 0.40 0.89 944 0.48 0.89 944 0.48 1.06 1011 0.57 4 1440 0.42 742 0.30 0.60 828 0.38 0.79 911 0.46 0.79 911 0.46 0.95 979 0.55 4 YHC048E1,3,4**L,M 1520 0.32 707 0.28 0.50 794 0.36 0.68 878 0.45 0.68 878 0.45 0.84 946 0.53 4 Horizontal 1600 0.22 671 0.27 0.40 760 0.35 0.57 845 0.43 0.57 845 0.43 0.73 913 0.51 4 Airflow 1680 0.13 636 0.26 0.29 725 0.33 0.46 812 0.41 0.46 812 0.41 0.62 881 0.49 4 1760 0.03 600 0.24 0.19 691 0.32 0.36 779 0.40 0.36 779 0.40 0.51 848 0.47 4 1840 - - - 0.09 657 0.30 0.25 746 0.38 0.25 746 0.38 0.40 815 0.46 4 1920 - - - - - - 0.14 713 0.36 0.14 713 0.36 0.29 783 0.44 5 1600 0.90 962 0.55 1.07 1027 0.64 1.28 1099 0.75 - - - - - - 5 1700 0.76 919 0.53 0.93 985 0.61 1.14 1060 0.72 - - - - - - 5 1800 0.62 875 0.50 0.78 943 0.59 0.99 1022 0.70 1.15 1092 0.81 - - - 5 YHC060E1,3,4**L,M 1900 0.48 832 0.48 0.64 900 0.56 0.84 984 0.67 1.00 1051 0.78 1.18 1116 0.89 5 Downflow 2000 0.34 788 0.45 0.49 858 0.53 0.70 945 0.65 0.86 1010 0.75 1.03 1076 0.86 5 Airflow 2100 0.20 745 0.43 0.35 815 0.51 0.55 907 0.62 0.71 969 0.72 0.88 1037 0.83 5 2200 0.06 701 0.40 0.20 773 0.48 0.41 868 0.59 0.56 928 0.69 0.73 997 0.80 5 2300 - - - 0.06 730 0.46 0.26 830 0.57 0.41 887 0.66 0.58 958 0.77 5 2400 - - - - - - 0.12 792 0.54 0.26 846 0.63 0.43 918 0.73 5 1600 0.75 944 0.54 0.91 1010 0.63 1.10 1094 0.75 - - - - - - 5 1700 0.61 899 0.52 0.77 969 0.60 0.96 1052 0.72 1.12 1114 0.82 - - - 5 1800 0.48 855 0.49 0.63 927 0.58 0.82 1011 0.69 0.97 1074 0.79 - - - 5 YHC060E1,3,4**L,M 1900 0.34 811 0.47 0.49 885 0.55 0.67 969 0.66 0.83 1035 0.76 1.01 1111 0.89 5 Horizontal 2000 0.20 766 0.44 0.35 843 0.53 0.53 928 0.63 0.68 995 0.74 0.87 1070 0.85 5 Airflow 2100 0.07 722 0.42 0.21 801 0.50 0.39 887 0.61 0.54 956 0.71 0.72 1028 0.82 5 2200 - - - 0.07 759 0.47 0.25 845 0.58 0.39 916 0.68 0.57 987 0.79 5 2300 - - - - 0.10 804 0.55 0.25 877 0.65 0.42 945 0.76 5 2400 - - - - - - - - - 0.10 837 0.62 0.27 904 0.72 For 036 Models, fan motor heat MB = 2.72 x Fan Bhp + 0.16. For 048 & 060 Models, fan motor heat (MBh) = 2.87 x Fan Bhp + 0.15. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Data includes pressure drop due to wet coil and filters. RT-PRCO23-EN 63 TRAWE WF Direct Drive - Evaporator Fan Performance Table 36. Multispeed direct drive evaporator fan performance 3 - 5 tons -high efficiency -high heat YHC036,048, 06OE1,3,4 External Static Pressure (Inches of Water) & Motor Power (Bhp)(a) Standard Low Standard High Rated Speed Mid Speed Speed High Speed Unit Model Speed Set 1 Speed Set 2 Speed Set 3 Speed Set 4 Speed Set 5 Tons Number cfm ESP rpm bhp ESP rpm bhp ESP rpm p ESP rpm bhp ESP rpm p 3 960 0.43 718 0.19 0.64 825 0.26 0.88 923 0.34 1.12 1017 0.44 1.2 1074 0.51 3 1020 0.37 696 0.19 0.57 800 0.26 0.80 900 0.34 1.04 997 0.43 1.20 1053 0.50 3 1080 0.30 675 0.18 0.49 775 0.25 0.72 877 0.33 0.96 977 0.42 1.11 1033 0.49 3 YHC036El,3,4**H 1140 0.24 654 0.18 0.42 749 0.24 0.64 854 0.32 0.87 957 0.42 1.03 1013 0.48 3 Downflow 1200 0.18 633 0.17 0.34 724 0.23 0.56 832 0.31 0.79 938 0.41 0.94 992 0.47 3 Airflow 1260 0.11 612 0.16 0.26 698 0.22 0.48 809 0.30 0.71 918 0.40 0.86 972 0.46 3 1320 0.05 590 0.16 0.19 673 0.21 0.39 786 0.29 0.63 898 0.39 0.77 951 0.45 3 1380 - - - 0.11 647 0.21 0.31 763 0.28 0.55 878 0.38 0.68 931 0.44 3 1440 - - - 0.03 622 0.20 0.23 740 0.28 0.47 859 0.37 0.60 910 0.43 3 960 0.44 732 0.20 0.65 836 0.27 0.87 935 0.35 1.12 1033 0.45 1.25 1078 0.51 3 1020 0.37 708 0.19 0.58 811 0.26 0.80 911 0.34 1.03 1010 0.44 1.17 1059 0.50 3 1080 0.31 684 0.18 0.51 787 0.25 0.72 886 0.33 0.95 987 0.43 1.09 1040 0.49 3 YHC036E1,3,4**H 1140 0.24 660 0.18 0.43 762 0.24 0.64 862 0.32 0.87 964 0.42 1.01 1021 0.48 3 Horizontal 1200 0.18 636 0.17 0.36 737 0.24 0.56 838 0.31 0.79 941 0.41 0.93 1002 0.47 3 Airflow 1260 0.11 612 0.16 0.29 712 0.23 0.48 814 0.30 0.70 918 0.40 0.85 983 0.47 3 1320 0.05 588 0.16 0.21 688 0.22 0.40 789 0.29 0.62 895 0.39 0.77 964 0.46 3 1380 - - - 0.14 663 0.21 0.32 765 0.28 0.54 872 0.38 0.69 945 0.45 3 1440 - - - 0.07 638 0.20 0.24 741 0.28 0.45 849 0.37 0.61 926 0.44 4 1280 0.69 833 0.35 0.90 924 0.43 1.07 989 0.51 1.07 989 0.51 1.27 1066 0.61 4 1360 0.60 796 0.33 0.80 889 0.42 0.97 956 0.50 0.97 956 0.50 1.17 1033 0.59 4 1440 0.50 759 0.32 0.71 855 0.40 0.87 922 0.48 0.87 922 0.48 1.06 1000 0.57 4 YHC048El,3,4**H 1520 0.40 722 0.30 0.61 820 0.39 0.77 889 0.46 0.77 889 0.46 0.96 966 0.56 4 Downflow 1600 0.31 684 0.29 0.51 785 0.37 0.67 855 0.44 0.67 855 0.44 0.85 933 0.54 4 Airflow 1680 0.21 647 0.27 0.41 751 0.35 0.57 822 0.43 0.57 822 0.43 0.75 900 0.52 4 1760 0.12 610 0.26 0.31 716 0.34 0.47 788 0.41 0.47 788 0.41 0.64 867 0.50 4 1840 - - - 0.22 681 0.32 0.37 755 0.39 0.37 755 0.39 0.54 834 0.48 4 1920 - - - 0.12 647 0.30 0.27 721 0.37 0.27 721 0.37 0.43 801 0.46 4 1280 0.60 822 0.34 0.81 912 0.43 0.97 986 0.51 0.97 986 0.51 1.18 1063 0.61 4 1360 0.51 787 0.33 0.70 876 0.41 0.87 952 0.49 0.87 952 0.49 1.07 1031 0.59 4 1440 0.41 752 0.31 0.60 840 0.40 0.76 918 0.48 0.76 918 0.48 0.96 998 0.57 4 YHC048E1,3,4**H 1520 0.31 718 0.30 0.49 805 0.38 0.66 885 0.46 0.66 885 0.46 0.84 966 0.56 4 Horizontal 1600 0.22 683 0.29 0.38 769 0.36 0.55 851 0.44 0.55 851 0.44 0.73 933 0.54 4 Airflow 1680 0.12 648 0.27 0.28 733 0.34 0.45 818 0.42 0.45 818 0.42 0.62 901 0.52 4 1760 0.03 613 0.26 0.17 697 0.33 0.34 784 0.41 0.34 784 0.41 0.51 868 0.50 4 1840 - - - 0.07 661 0.31 0.23 750 0.39 0.23 750 0.39 0.40 836 0.48 4 1920 - - - - - - 0.13 717 0.37 0.13 717 0.37 0.29 803 0.46 5 1600 0.90 955 0.57 1.06 1022 0.66 1.25 1095 0.77 - - - - - - 5 1700 0.76 910 0.54 0.92 977 0.63 1.11 1052 0.74 1.28 1113 0.85 - - - 5 1800 0.62 865 0.52 0.77 932 0.60 0.96 1009 0.71 1.13 1072 0.82 - - - 5 YHC060E1,3,4**H 1900 0.47 819 0.49 0.63 888 0.57 0.82 966 0.68 0.98 1031 0.79 1.18 1105 0.91 5 Downflow 2000 0.33 774 0.46 0.49 843 0.54 0.67 922 0.65 0.83 990 0.75 1.02 1062 0.87 5 Airflow 2100 0.19 729 0.44 0.34 798 0.52 0.52 879 0.62 0.68 949 0.72 0.87 1019 0.84 5 2200 0.04 683 0.41 0.20 754 0.49 0.38 836 0.59 0.54 908 0.69 0.71 976 0.80 5 2300 - - - 0.05 709 0.46 0.23 793 0.56 0.39 867 0.66 0.55 933 0.77 5 2400 - - - - - - 0.09 750 0.53 0.24 826 0.63 0.40 890 0.73 5 1600 0.77 948 0.57 0.95 1016 0.66 1.10 1093 0.77 - - - - - - 5 1700 0.63 903 0.54 0.80 973 0.63 0.96 1052 0.74 - - - - - - 5 1800 0.48 859 0.51 0.66 930 0.60 0.81 1012 0.71 1.00 1084 0.83 - - - 5 YHC060E1,3,4**H 1900 0.34 814 0.49 0.51 888 0.57 0.67 971 0.68 0.85 1042 0.79 1.01 1106 0.91 5 Horizontal 2000 0.20 770 0.46 0.36 845 0.55 0.52 931 0.65 0.70 1000 0.76 0.86 1063 0.87 5 Airflow 2100 0.06 725 0.43 0.22 803 0.52 0.38 890 0.62 0.55 959 0.73 0.70 1021 0.84 5 2200 - - - 0.07 760 0.49 0.23 850 0.60 0.39 917 0.70 0.54 979 0.80 5 2300 - - - - - - 0.09 809 0.57 0.24 875 0.67 0.39 937 0.77 5 2400 - - - - - - - - 0.00 0.09 833 0.63 0.23 894 0.73 For 036 Models, fan motor heat MB = 2.72 x Fan Bhp + 0.16. For 048 & 060 Models, fan motor heat MB = 2.87 x Fan Bhp + 0.15. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Data includes pressure drop due to wet coil and filters 64 RT-PRCO23-EN 0 TRANE' Evaporator Fan Performance Table 37. Belt drive evaporator fan performance - 3 tons standard efficiency - TSC036E3,E4,EW downf low airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 960 - - - - 614 0.17 683 0.22 742 0.27 795 0.32 845 0.37 891 0.42 935 0.47 977 0.53 1080 - - 561 0.15 635 0.20 704 0.25 765 0.30 818 0.36 868 0.42 913 0.47 957 0.53 998 0.59 1200 - - 592 0.18 658 0.23 725 0.29 786 0.35 842 0.41 891 0.47 936 0.53 979 0.59 1019 0.66 1320 555 0.17 625 0.22 686 0.27 747 0.33 807 0.39 862 0.46 914 0.53 959 0.59 1002 0.66 1043 0.73 1440 592 0.21 658 0.27 717 0.32 772 0.38 828 0.44 882 0.51 933 0.58 980 0.66 1025 0.73 1065 0.80 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1016 0.59 1054 0.65 1089 0.70 1124 0.76 1155 0.82 1080 1036 0.65 1075 0.72 1111 0.78 1146 0.84 1180 0.91 1200 1058 0.72 1095 0.78 1131 0.85 1167 0.92 1201 0.99 1320 1082 0.80 1119 0.87 1153 0.94 1188 1.01 1221 1.08 1440 1104 0.88 1141 0.95 1176 1.03 1211 1.10 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK71x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 65 TRAME WF Evaporator Fan Performance Table 38. Belt drive evaporator fan performance - 3 tons standard efficiency - TSC036E3,E4,EW horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drivem 1-hp Standard Motor & Drive(b) 960 - - 552 0.12 626 0.16 689 0.20 748 0.25 802 0.30 852 0.35 898 0.39 942 0.44 982 0.49 1080 - - 576 0.14 654 0.19 716 0.24 772 0.29 825 0.34 874 0.39 921 0.45 964 0.50 1005 0.55 1200 - - 600 0.17 681 0.23 744 0.28 799 0.33 850 0.39 898 0.44 943 0.50 987 0.56 1028 0.62 1320 554 0.16 627 0.20 705 0.27 773 0.33 828 0.38 877 0.44 923 0.50 967 0.56 1010 0.62 1052 0.69 1440 590 0.20 657 0.24 728 0.30 797 0.37 855 0.44 904 0.50 950 0.56 993 0.63 1034 0.69 1074 0.76 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1020 0.54 1057 0.59 1092 0.64 1126 0.69 1158 0.74 1080 1045 0.61 1082 0.67 1116 0.72 1151 0.77 1183 0.83 1200 1067 0.68 1104 0.74 1141 0.80 1174 0.86 1207 0.92 1320 1091 0.75 1127 0.82 1163 0.88 1198 0.95 1230 1.02 1440 1112 0.83 1150 0.90 1186 0.97 1221 1.04 1254 1.11 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK71x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK410/4" required. Field Supplied Belt may be necessary. 66 RT-PRCO23-EN qW TRANE Evaporator Fan Performance Table 39. Belt drive evaporator fan performance - 3 tons standard efficiency - YSC036E3,E4,EW*L,1Vl low & medium gas heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 960 - - - - 605 0.15 671 0.19 730 0.23 784 0.27 835 0.31 881 0.36 924 0.41 965 0.45 1080 - - 563 0.14 630 0.17 693 0.22 751 0.26 804 0.31 854 0.35 901 0.40 946 0.46 986 0.50 1200 - - 596 0.17 659 0.21 718 0.25 773 0.30 825 0.35 875 0.40 921 0.45 964 0.51 1005 0.56 1320 555 0.16 629 0.20 689 0.25 745 0.29 797 0.34 848 0.40 897 0.45 941 0.51 984 0.56 1026 0.62 1440 593 0.20 663 0.25 721 0.29 775 0.34 824 0.39 873 0.45 919 0.51 963 0.57 1006 0.63 1046 0.69 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1004 0.50 1039 0.55 1073 0.59 1105 0.64 1137 0.69 1080 1025 0.56 1063 0.61 1098 0.66 1132 0.72 1163 0.77 1200 1046 0.62 1082 0.67 1119 0.73 1153 0.79 1187 0.85 1320 1064 0.68 1103 0.74 1139 0.80 1174 0.86 1207 0.93 1440 1085 0.75 1123 0.81 1159 0.88 1193 0.94 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK710/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 67 TRAMS WF Evaporator Fan Performance Table 40. Belt drive evaporator fan performance - 3 tons standard efficiency - YSC036E3,E4,EW*L,M low & medium gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 960 - - - - 613 0.15 679 0.20 736 0.24 788 0.28 837 0.32 886 0.37 930 0.42 973 0.47 1080 - - 561 0.14 636 0.18 702 0.23 761 0.28 812 0.32 860 0.37 904 0.42 947 0.47 991 0.52 1200 - - 589 0.16 661 0.21 726 0.26 784 0.31 836 0.37 884 0.42 929 0.47 970 0.52 1011 0.58 1320 - - 619 0.20 687 0.25 1440 585 0.19 651 0.24 715 0.29 750 0.30 807 0.36 859 0.41 F775 0.35 831 0.40 883 0.47 909 0.47 953 0.53 995 0.59 931 0.53 976 0.59 1019 0.66 1034 0.65 1058 0.72 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1014 0.53 1051 0.58 1087 0.63 1121 0.68 1155 0.74 1080 1031 0.58 1071 0.64 1108 0.69 1142 0.75 1177 0.81 1200 1049 0.63 1087 0.69 1124 0.75 1161 0.82 1195 0.88 1320 1071 0.70 1107 0.76 1143 0.82 1178 0.89 1213 0.96 1440 1095 0.78 1130 0.84 1166 0.91 1199 0.97 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK710/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK410/4" required. Field Supplied Belt may be necessary. 68 RT-PRCO23-EN qW TRANE Evaporator Fan Performance Table 41. Belt drive evaporator fan performance - 3 tons standard efficiency - YSC036E3,E4,EW*H high gas heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 960 - - - - 609 0.15 671 0.19 730 0.24 785 0.28 835 0.33 881 0.37 924 0.42 966 0.47 1080 - - 572 0.14 638 0.18 697 0.23 752 0.27 805 0.32 855 0.37 900 0.42 945 0.47 986 0.53 1200 - - 606 0.18 668 0.22 725 0.26 778 0.31 827 0.36 876 0.42 922 0.47 964 0.52 1007 0.58 1320 573 0.17 641 0.22 700 0.26 754 0.31 805 0.36 853 0.41 898 0.47 942 0.53 985 0.59 1026 0.65 1440 613 0.21 677 0.27 733 0.31 F786 0.36 835 0.42 881 0.47 925 0.53 966 0.59 1007 0.65 1047 0.71 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1004 0.52 1041 0.58 1076 0.63 1109 0.68 1142 0.73 1080 1026 0.58 1063 0.64 1098 0.69 1133 0.75 1165 0.81 1200 1046 0.64 1083 0.70 1120 0.76 1154 0.82 1187 0.88 1320 1065 0.71 1103 0.77 1139 0.83 1175 0.90 1207 0.96 1440 1086 0.78 1123 0.84 1160 0.91 1194 0.98 1227 1.05 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK71x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 69 TRAMS WF Evaporator Fan Performance Table 42. Belt drive evaporator fan performance - 3 tons standard efficiency - YSC036E3,E4,EW*H high gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 960 - - - - 621 0.15 685 0.20 745 0.24 799 0.29 849 0.33 894 0.38 936 0.42 975 0.47 1080 - - 580 0.14 649 0.19 711 0.23 768 0.28 821 0.32 871 0.38 917 0.43 960 0.48 1000 0.53 1200 - - 613 0.18 679 0.22 738 0.27 793 0.32 845 0.37 892 0.42 939 0.48 982 0.53 1024 0.59 1320 574 0.17 647 0.22 710 0.26 767 0.31 820 0.37 870 0.42 917 0.48 962 0.53 1004 0.59 1046 0.66 1440 612 0.21 682 0.26 742 0.31 797 0.37 849 0.42 897 0.48 943 0.54 986 0.60 1028 0.66 1068 0.72 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(h) 960 1012 0.52 1048 0.57 1082 0.62 1116 0.67 1148 0.72 1080 1039 0.59 1075 0.64 1109 0.69 1142 0.74 1173 0.80 1200 1063 0.65 1100 0.71 1134 0.77 1168 0.83 1199 0.88 1320 1085 0.72 1122 0.78 1159 0.85 1193 0.91 1226 0.98 1440 1107 0.79 1145 0.86 1181 0.93 1216 1.00 1248 1.07 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK71x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 70 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 43. Belt drive evaporator fan performance - 3 tons standard efficiency - WSC036E3,E4,EW downf low airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drivem 1-hp Standard Motor & Drive(b) 960 572 0.14 639 0.19 702 0.23 F762 0.28 816 0.34 865 0.39 907 0.44 948 0.49 986 0.54 1080 - - 608 0.18 672 0.23 731 0.27 785 0.33 840 0.38 890 0.44 937 0.50 979 0.56 1017 0.62 1200 572 0.18 645 0.23 707 0.28 762 0.33 814 0.38 864 0.44 913 0.50 961 0.57 1005 0.63 1046 0.70 1320 614 0.22 684 0.28 744 0.33 797 0.39 846 0.44 894 0.50 939 0.56 984 0.63 1028 0.70 1070 0.78 1440 656 0.27 723 0.34 r781 0.40 833 0.46 881 0.52 925 0.58 969 0.64 1011 0.71 1053 0.78 1094 0.86 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1022 0.59 1057 0.64 1092 0.69 1125 0.74 1157 0.79 1080 1053 0.67 1088 0.73 1121�79152 0.84 11840.90 1200 1084 0.77 1118 0.83 1152182 0.95 1213 1.01 1320 1110 0.85 1147 0.92 1182 1.00 1214 1.07 - - 1440 1133 0.94 1170 1.01 1207 1.10 - - - - 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK71x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK410/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 71 TRAMS WF Evaporator Fan Performance Table 44. Belt drive evaporator fan performance - 3 tons standard efficiency - WSC036E3,E4,EW horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 960 560 0.13 641 0.17 711 0.22 770 0.27 822 0.32 868 0.37 911 0.41 952 0.46 991 0.52 1080 - - 589 0.16 665 0.21 735 0.26 796 0.31 850 0.37 899 0.42 942 0.48 983 0.53 1021 0.58 1200 551 0.15 622 0.19 691 0.24 758 0.30 820 0.36 875 0.42 925 0.48 971 0.54 1012 0.60 1052 0.66 1320 592 0.19 657 0.24 720 0.29 783 0.35 843 0.41 899 0.47 950 0.54 997 0.60 1041 0.67 1081 0.74 1440 634 0.24 695 0.29 753 0.34 810 0.40 867 0.46 922 0.53 974 0.60 1022 0.67 1066 0.75 1108 0.82 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1028 0.57 1064 0.62 1099 0.67 1133 0.73 1165 0.78 1080 1057 0.64 1093 0.70 1127 0.75 1160 0.81 1192 0.87 1200 1087 0.72 1123 0.78 1156 0.84 1189 0.90 1221 0.97 1320 1118 0.80 1153 0.87 1187 0.94 1218 1.00 - - 1440 1146 0.89 1182 0.97 1217 1.04 - - - - 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK71x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 72 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 45. Belt drive evaporator fan performance - 4 tons standard efficiency - TSC048E3,E4,EW downf low airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1280 - - 1 619 0.20 680 0.24 735 0.29 789 0.34 843 0.39 894 0.45 940 0.51 983 0.56 1025 0.63 1440 597 0.20 664 0.25 724 0.30 775 0.35 823 0.40 872 0.46 921 0.52 968 0.58 1012 0.65 1052 0.71 1600 648 0.26 710 0.32 768 0.37 818 0.43 864 0.49 908 0.54 950 0.60 995 0.67 1039 0.74 1081 0.81 1760 700 0.34L8O0.39 812 0.46 862 0.52 907 0.58 948 0.64 988 0.71 1027 0.77 1068 0.84 1108 0.91 1920 753 0.430.49 858 0.55 906 0.62 952 0.70 992 0.76 1029 0.83 1066 0.89 1102 0.96 1138 1.03 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1063 0.69 1101 0.75 1138 0.81 1175 0.88 1208 0.94 1440 1091 0.78 1128 0.85 1164 0.91 1198 0.98 1233 1.05 1600 1120 0.88 1157 0.95 1193 1.02 1227 1.10 1259 1.17 1760 1147 0.99 1185 1.07 1220 1.14 1256 1.23 - - 1920 1174 1.11 1212 1.19 1247 1.27 - - - - 1-hp Standard Motor & Field Supplied High Static Drive(c) Note: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 73 TRAME WF Evaporator Fan Performance Table 46. Belt drive evaporator fan performance - 4 tons standard efficiency - TSC048E3,E4,EW horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drivem 1-hp Standard Motor & Drive(b) 1280 - - 1 633 0.20 704 0.26 767 0.31 822 0.37 871 0.42 915 0.48 957 0.54 997 0.60 1035 0.66 1440 604 0.20 676 0.26 744 0.32 805 0.38 859 0.44 909 0.50 954 0.57 996 0.63 1035 0.69 1073 0.76 1600 656 0.27 721 0.32 785 0.39 843 0.45 897 0.52 946 0.59 991 0.66 1034 0.73 1075 0.80 1110 0.87 1760 709 0.34 768 0.40 827 0.47 883 0.54 936 0.61 984 0.69 1030 0.77 1072 0.84 1113 0.92 1149 1.00 1920 762 0.43 817 0.50 872 0.57 925 0.64 975 0.72 1023 0.80 1067 0.88 1109 0.97 1150 1.05 1188 1.14 Standard Motor & Field Supplied Low Static Drive(a) Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1072 0.71 1107 0.77 1142 0.84 1176 0.90 1210 0.97 1440 1108 0.83 1143 0.89 1176 0.96 1209 1.02 1239 1.09 1600 1146 0.95 1180 1.02 1212 1.09 1243 1.16 - - 1760 1185 1.08 1219 1.16 1251 1.24 - - - - 1920 1223 1.22 1258 1.31 - - - - - - 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 74 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 47. Belt drive evaporator fan performance - 4 tons standard efficiency - YSC048E3,E4,EW*L,M low & medium gas heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1280 571 0.17 641 0.22 701 0.26 755 0.31 807 0.36 858 0.42 907 0.49 953 0.55 996 0.61 1037 0.67 1440 624 0.23 689 0.28 747 0.33 799 0.39 1 847 0.44 892 0.50 938 0.56 983 0.63 1027 0.71 1067 0.78 1600 679 0.30 740 0.35 794 0.41 844 0.47 890 0.53 933 0.59 975 0.66 1016 0.72 1057 0.80 1097 0.88 1760 735 0.38 791 0.44 843 0.51 891 0.58 936 0.64 977 0.71 1017 0.77 1056 0.84 1092 0.91 1130 0.99 1920 791 0.48 844 0.55 893 0.62 939 0.69 982 0.76 1023 0.84 1061 0.91 1097 0.98 1133 1.05 1168 1.13 1-hp Standard Motor & Drive(b) Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1075 0.73 1113 0.79 1147 0.85 1181 0.92 1215 0.98 1440 1106 0.85 1143 0.91 1179 0.98 1211 1.05 1245 1.11 1600 1137 0.96 11173 1.04 1209 1.12 1242 1.19 - - 1760 1166 1.07 1203 1.16 1239 1.25 - - - - 1920 1201 1.21 1236 1.29 - - - - - - 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 75 TRAMS WF Evaporator Fan Performance Table 48. Belt drive evaporator fan performance - 4 tons standard efficiency - YSC048E3,E4,EW*L,M low & medium gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1280 -- 638 0.21 704 0.26 766 0.31 822 0.37 875 0.42 922 0.48 968 0.54 1010 0.60 1052 0.66 1440 621 0.22 685 0.26 746 0.32 804 0.38 858 0.44 909 0.50 957 0.56 1002 0.63 1043 0.70 1084 0.76 1600 676 0.29 734 0.34 790 0.39 844 0.45 896 0.52 946 0.59 992 0.66 1036 0.73 1078 0.80 1118 0.87 1760 732 0.37 786 0.42 838 0.48 888 0.55 936 0.62 984 0.69 1029 0.76 1071 0.84 1112 0.91 1152 0.99 1920 789 0.47 1 839 0.53 887 0.59 934 0.66 979 0.73 1023 0.80 1067 0.88 1108 0.96 1149 1.04 1187 1.13 1-hp Standard Motor & Field Supplied High Static Drive(c) Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1091 0.73 1129 0.79 1166 0.85 1201 0.92 1234 0.98 1440 1122 0.83 1159 0.90 1196 0.97 1230 1.04 - - 1600 1155 0.95 1192 1.02 1228 1.10 1261 1.17 - - 1760 1189 1.07 1225 1.15 1261 1.24 - - - - 1920 1225 1.21 1260 1.30 - - - - - - 1-hp Standard Motor & Field Supplied High Static Drive(C) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 76 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 49. Belt drive evaporator fan performance - 4 tons standard efficiency - YSC048E3,E4,EW*H high gas heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1280 586 0.17 652 0.21 711 0.26 766 0.31 818 0.36 870 0.41 919 0.47 965 0.53 1008 0.59 1049 0.65 1440 642 0.23 704 0.28 759 0.33 810 0.38 859 0.43 906 0.49 951 0.55 996 0.61 1039 0.68 1080 0.74 1600 699 0.30 757 0.36 809 0.41 857 0.47 903 0.53 947 0.59 990 0.65 1030 0.71 1071 0.78 1111 0.85 1760 757 0.39 811 0.45 861 0.51 906 0.57 950 0.63 991 0.70 1031 0.76 1071 0.83 1109 0.90 1146 0.97 1920 816 0.49 867 0.56 914 0.63 957 0.69 998 0.76 1037 0.82 1076 0.89 1113 0.96 1149 1.04 1184 1.11 1-hp Standard Motor & Field Supplied High Static Drive(c) Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1086 0.71 1122 0.77 1157 0.83 1190 0.89 1221 0.94 1440 1119 0.81 1156 0.88 1191 0.94 1224 1.01 1257 1.08 1600 1151 0.92 11187 0.99 1223 1.07 1258 1.14 - - 1760 1182 1.04 1218 1.12 1255 1.20 - - - - 1920 1219 1.19 1252 1.27 - - - - - - 1-hp Standard Motor & Field Supplied High Static Drive(C) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 77 TRAMS WF Evaporator Fan Performance Table 50. Belt drive evaporator fan performance - 4 tons standard efficiency - YSC048E3,E4,EW*H high gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1280 587 0.18 659 0.23 722 0.28 782 0.33 835 0.39 886 0.45 931 0.51 975 0.57 1016 0.64 1056 0.70 1440 641 0.24 709 0.29 769 0.35 824 0.41 876 0.47 924 0.53 970 0.60 1013 0.67 1053 0.74 1092 0.81 1600 696 0.31 761 0.37 817 0.44 869 0.50 918 0.56 965 0.63 1009 0.70 1053 0.78 1092 0.85 1131 0.93 1760 753 0.40 813 0.47 867 0.54 917 0.61 963 0.68 1008 0.75 1051 0.82 1092 0.90�21.. 1169 1.06 1920 810 0.50 867 0.58 919 0.66 966 0.73 1011 0.81 1053 0.88 1094 0.96 1134 1.041209 1.21 1-hp Standard Motor & Field Supplied High Static Drive(c) Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1095 0.76 1131 0.83 1167 0.89 1200 0.95 1233 1.02 1440 1130 0.88 1164 0.95 1199 1.02 1234 1.09 - - 1600 1167 1.00 1201 1.08 1236 1.16 - - - - 1760 1206 1.14 1240 1.22 - - - - - - 1920 1245 1.30 - - - - - - 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 78 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 51. Belt drive evaporator fan performance - 4 tons standard efficiency - WSC048E3,E4,EW downf low airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive�e) 1-hp Standard Motor & Drive(b) 1280 - - 619 0.20 680 0.24 735 0.29 789 0.34 843 0.39 894 0.45 940 0.51 983 0.56 1025 0.63 1440 597 0.20 664 0.25 724 0.30 775 0.35 823 0.40 872 0.46 921 0.52 968 0.58 1012 0.65 1052 0.71 1600 648 0.26 710 0.32 768 0.37 818 0.43 864 0.49 908 0.54 950 0.60 995 0.67 1039 0.74 1081 0.81 1760 700 0.34L8O 0.39 812 0.46 862 0.52 907 0.58 948 0.64 988 0.71 1027 0.77 1068 0.84 1108 0.91 1920 753 0.430.49 858 0.55 906 0.62 952 0.70 992 0.76 1029 0.83 1066 0.89 1102 0.96 1138 1.03 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1063 0.69 1101 0.75 1138 0.81 1175 0.88 1208 0.94 1440 1091 0.78 1128 0.85 1164 0.91 1198 0.98 1233 1.05 1600 1120 0.88 1157 0.95 1193 1.02 1227 1.10 1259 1.17 1760 1147 0.99 1185 1.07 1220 1.14 1256 1.23 - - 1920 1174 1.11 1212 1.19 1247 1.27 - - - - 1-hp Standard Motor & Field Supplied High Static Drive(c) Note: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 79 TRAMS WF Evaporator Fan Performance Table 52. Belt drive evaporator fan performance - 4 tons standard efficiency - WSC048E3,E4,EW horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drivem 1-hp Standard Motor & Drive(b) 1280 - - 1 633 0.20 704 0.26 767 0.31 822 0.37 871 0.42 915 0.48 957 0.54 997 0.60 1035 0.66 1440 604 0.20 676 0.26 744 0.32 805 0.38 859 0.44 909 0.50 954 0.57 996 0.63 1035 0.69 1073 0.76 1600 656 0.27 721 0.32 785 0.39 843 0.45 897 0.52 946 0.59 991 0.66 1034 0.73 1075 0.80 1110 0.87 1760 709 0.34 768 0.40 827 0.47 883 0.54 936 0.61 984 0.69 1030 0.77 1072 0.84 1113 0.92 1149 1.00 1920 762 0.43 817 0.50 872 0.57 925 0.64 975 0.72 1023 0.80 1067 0.88 1109 0.97 1150 1.05 1188 1.14 Standard Motor & Field Supplied High Static Drive(c) Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1072 0.71 1107 0.77 1142 0.84 1176 0.90 1210 0.97 1440 1108 0.83 1143 0.89 1176 0.96 1209 1.02 1239 1.09 1600 1146 0.95 1180 1.02 1212 1.09 1243 1.16 - - 1760 1185 1.08 1219 1.16 1251 1.24 - - - - 1920 1223 1.22 1258 1.31 - - - - - - 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 80 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 53. Belt drive evaporator fan performance - 5 tons standard efficiency - TSC060E3,E4,EW downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Driveta1-hp Standard Motor & Drive(b) 1600 -- 706 0.31 763 0.37 814 0.42 862 0.47 908 0.53 951 0.59 992 0.65 1031 0.71 1069 0.77 1800 710 0.35 767 0.41 819 0.47 868 0.53 913 0.59 957 0.66 998 0.72 1038 0.78 1075 0.85 1112 0.91 2000 777 0.46 828 0.53 1 877 0.60 924 0.67 967 0.74 1008 0.80 1047 0.87 1086 0.94 1122 1.01 1157 1.08 2200 844 0.60 1 892 0.68 938 0.75 981 0.83 1022 0.90 1061 0.97 1099 1.05 1136 1.13 1170 1.20 1205 1.28 2400 912 0.77 957 0.85 999 0.93 1040 1.01 1079 1.09 1117 1.17 1153 1.25 1187 1.33 1222 1.42 1254 1.50 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive 1600 1105 0.83 1140 0.89 1174 0.96 1209 1.03 1242 1.10 1800 1146 0.98 1181 1.05 1213 1.12 1245 1.19 1276 1.26 2000 1191 1.15 1225 1.23 1256 1.30 1287 1.37 - - 2200 1238 1.35 19 1.43 - - - - - - 2400 1286 1.58 26- - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure 5. drop due to other options/accessories. 6. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 7. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK61x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK44x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 81 TRAME WF Evaporator Fan Performance Table 54. Belt drive evaporator fan performance - 5 tons standard efficiency - TSC060E3,E4,EW horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drivem 1-hp Standard Motor & Drive(b) 1600 653 0.26 714 0.31 774 0.37 829 0.43 879 0.48 924 0.54 967 0.60 1007 0.66 1045 0.71 1082 0.78 1800 720 0.36 775 0.41 829 0.47 881 0.54 930 0.60 975 0.67 1016 0.73 1055 0.79 1093 0.86 1128 0.92 2000 787 0.47 837 0.54 887 0.60 935 0.67 982 0.74 1026 0.81 1068 0.88 1106 0.96 1142 1.03 1176 1.10 2200 856 0.61 902 0.68 947 0.75 992 0.83 1036 0.90 1078 0.98 1119 1.06 1157 1.14 1193 1.22 1227 1.30 2400 926 0.78 969 0.86 1010 0.94 1051 1.01 1092 1.09 1131 1.17 1170 1.26 1208 1.35 1244 1.43 1278 1.52 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1118 0.84 1152 0.90 1187 0.97 1219 1.04 1253 1.11 1800 1163 0.99 1195 1.06 1228 1.13 1260 1.20 1291 1.28 2000 1210 1.17 1243 1.24 1274 1.32 - - - - 2200 1260 1.38 1292 1.45 - - - - - - 2400 - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK61x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK44x3/4" required. Field Supplied Belt may be necessary. 82 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 55. Belt drive evaporator fan performance - 5 tons standard efficiency - YSC060E3,E4,EW*L,M low & medium gas heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1600 704 0.31 762 0.36 815 0.42 861 0.47 904 0.53 947 0.58 987 0.64 1028 0.70 1064 0.75 1101 0.82 1800 777 0.42 831 0.48 880 0.54 925 0.60 966 0.67 1005 0.73 1043 0.79 1080 0.86 1116 0.92 1151 0.98 2000 851 0.56 901 0.63 947 0.70 990 0.77 1031 0.83 1068 0.90 1102 0.97 1137 1.04 1171 1.11 1205 1.18 2200 926 0.73 973 0.81 1016 0.88 1057 0.96 1096 1.03 1131 1.10 1165 1.18 1198 1.26 1229 1.33 1260 1.41 2400 1002 0.93 1045 1.01 1086 1.10 1124 1.18 1162 1.26 1197 1.34 1230 1.42 1261 1.51 1291 1.59 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1137 0.88 1172 0.95 1205 1.01 1238 1.08 1270 1.15 1800 1186 1.05 1217 1.12 1251 1.19 1281 1.26 - - 2000 1237 1.25 1269 1.32 - - - - - - 2200 1291 1.49 - - - - - - - - 2400 - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK61x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK44x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 83 TRAMS WF Evaporator Fan Performance Table 56. Belt drive evaporator fan performance - 5 tons standard efficiency - YSC060E3,E4,EW*L,M low & medium gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1600 -- 732 0.33 789 0.38 843 0.43 894 0.49 941 0.55 986 0.61 1028 0.68 1069 0.74 1107 0.80 1800 741 0.38 795 0.43 848 0.49 898 0.55 946 0.61 991 0.68 1034 0.74 1075 0.81 1114 0.88 1151 0.95 2000 811 0.50 861 0.57 909 0.63 956 0.69 1000 0.76 1044 0.83 1084 0.90 1124 0.97 1162 1.05 1198 1.12 2200 883 0.65 929 0.72 973 0.79 1016 0.86 1058 0.94 1098 1.01 1138 1.09 1176 1.16 1213 1.24 1249 1.32 2400 955 0.83 997 0.91 1038 0.99 1078 1.06 1118 1.14 1156 1.22 1193 1.30 1229 1.38 1264 1.46 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1144 0.87 1180 0.94 1213 1.00 1247 1.07 1279 1.14 1800 1188 1.02 1224 1.10 1257 1.17 1289 1.24 - - 2000 1234 1.20�12691.28 - - - - - - 2200 1282 1.40- - - - - - 2400 - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK61x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK44x3/4" required. Field Supplied Belt may be necessary. 84 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 57. Belt drive evaporator fan performance - 5 tons standard efficiency - YSC060E3,E4,EW*H high gas heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1600 714 0.32 773 0.37 827 0.43 873 0.48 916 0.54 959 0.60 1003 0.66 1044 0.73 1083 0.79 1122 0.86 1800 788 0.44 842 0.50 893 0.56 939 0.62 980 0.68 1019 0.75 1056 0.81 1095 0.88 1133 0.95 1170 1.02 2000 863 0.58 914 0.65 961 0.72 1005 0.79 1045 0.86 1082 0.93 1117 0.99 1152 1.07 1187 1.14 1221 1.22 2200 939 0.76 986 0.84 1030 0.92 1073 0.99 1112 1.07 1148 1.14 1182 1.21 1214 1.29 1246 1.37 1277 1.44 2400 1016 0.97 1060 1.05 1101 1.14 1141 1.22 1179 1.31 1215 1.39 1248 1.47 1280 1.55 - - - - Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1157 0.92 1193 0.99 1226 1.06 1258 1.12 1290 1.19 1800 1205 1.10 1240 1.17 1273 1.24 - - - - 2000 1256 1.30 1289 1.38 - - - - - - 2200 - - - - - - - - - - 2400 - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK61x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK44x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 85 TRAMS WF Evaporator Fan Performance Table 58. Belt drive evaporator fan performance - 5 tons standard efficiency - YSC060E3,E4,EW*H high gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1600 711 0.30 769 0.36 823 0.41 874 0.47 923 0.53 969 0.59 1010 0.65 1050 0.71 1088 0.78 1126 0.84 1800 784 0.42 839 0.48_j 889 0.54 935 0.60 981 0.67 1024 0.73 1066 0.80 1104 0.87 1142 0.94 1177 1.00 2000 859 0.56 910 0.63 956 0.69 999 0.76 1041 0.83 1083 0.90 1123 0.98 1161 1.05 1197 1.12 1232 1.20 2200 934 0.72 982 0.80 1026 0.88 1067 0.95 1106 1.03 1144 1.10 1181 1.18 1218 1.26 1254 1.34 1288 1.42 2400 1010 0.92 1055 1.01 1097 1.09 1135 1.17 1173 1.25 1208 1.34 1242 1.42 1277 1.50 - - - - Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1163 0.91 1197 0.98 1232 1.05 1265 1.12 1296 1.19 1800 1211 1.08 1244 1.15 1278 1.22 - - - - 2000 1265 1.28 - - - - - - - - 2200 - - - - - - - - - - 2400 - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK61x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK44x3/4" required. Field Supplied Belt may be necessary. 86 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 59. Belt drive evaporator fan performance - 5 tons standard efficiency - WSC060E3,E4,EW downf low airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1600 - - - - 623 0.26 681 0.31 734 0.36 783 0.41 831 0.46 878 0.52 923 0.58 965 0.64 1800 - - 594 0.27 656 0.32 712 0.38 763 0.43 810 0.49 855 0.54 899 0.60 941 0.67 983 0.73 2000 571 0.28 633 0.34 690 0.40 744 0.46 794 0.52 840 0.58 883 0.64 924 0.71 964 0.77 1003 0.84 2200 615 0.36 674 0.42 727 0.49 778 0.55 826 0.62 871 0.69 913 0.76 953 0.82 991 0.89 1030 0.96 2400 660 0.45 715 0.52 766 0.59 814 0.66 859 0.74 903 0.81 945 0.88 984 0.96 1021 1.03 1057 1.11 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1005 0.71 1045 0.78 1083 0.84 1120 0.91 1155 0.98 1800 1023 0.80 1062 0.87 1098 0.94 1134 1.01 1170 1.09 2000 1041 0.91 1079 0.98 1116 1.06 1152 1.13 1186 1.21 2200 1065 1.03 1100 1.11 1135 1.18 1169 1.26 1203 1.34 2400 1092 1.18 1125 1.26 1159 1.34 1191 1.41 1223 1.50 i-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 87 TRAMS WF Evaporator Fan Performance Table 60. Belt drive evaporator fan performance - 5 tons standard efficiency - WSC060E3,E4,EW horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drivem 1-hp Standard Motor & Drive(b) 1600 585 0.23 659 0.29 724 0.35 787 0.42 846 0.49 901 0.56 950 0.64 995 0.71 1038 0.78 1800 -- 622 0.29 690 0.36 753 0.43 811 0.49 866 0.57 922 0.65 973 0.73 1020 0.81 1064 0.90 2000 598 0.31 661 0.37 724 0.44 784 0.52 840 0.59 893 0.66 943 0.74 993 0.83 1041 0.92 1085 1.01 2200 647 0.40 703 0.46 761 0.54 817 0.62 870 0.70 921 0.78 970 0.86 1016 0.95 1061 1.04 1106 1.13 2400 696 0.50 746 0.57 799 0.65 853 0.74 903 0.82 952 0.91 998 1.00 1043 1.09 1086 1.18 1127 1.27 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1078 0.86 1115 0.93 1150 1.01 1183 1.08 1214 1.16 1800 1105 0.98 1143 1.06 1180 1.15 1215 1.23 - - 2000 1128 1.10 1169 1.20 1207 1.29 - - - - 2200 1150 1.24 1190 1.34 - - - - - - 2400 1170 1.38 1211 1.48 - - - - - - 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK410/4" required. Field Supplied Belt may be necessary. 88 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 61. Belt drive evaporator fan performance - 6 tons standard efficiency - TSC072E3,4,W downf low airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drivem 1-hp Standard Motor & Drive 1920 - - - - 588 0.35 643 0.43 693 0.50 738 0.57 782 0.65 823 0.73 862 0.81 900 0.89 2160 - - 564 0.37 618 0.44 672 0.52 721 0.60 765 0.68 806 0.76 847 0.85 885 0.93 922 1.02 2400 2640 2880 - - 602 0.47 652 0.54 701 0.63 750 0.72 794 0.81 834 0.90 589 0.50 642 0.59 690 0.67 734 0.76 779 0.85 822 0.95 864 1.05 634 0.63 682 0.74 728 0.82 770 0.91 810 1.01 851 1.11 892 1.22 873 0.98 909 1.08 945 1.17 901 1.15 936 1.24 971 1.34 930 1.33 965 1.44 999 1.54 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive 1-hp Standard Motor & High Static Drive Kit (or 2-hp Oversized Motor & Drive) 1920 937 0.98 971 1.06 1004 1.14 1037 1.22 1068 1.30 1097 1.38 1127 1.47 1154 1.55 1182 1.64 1210 1.74 2160 957 1.12 991 1.21 1024 1.30 1057 1.40 1087 1.49 1117 1.58 1146 1.67 1174 1.76 1201 1.85 1227 1.95 2400 980 1.27 1013 1.37 1046 1.47 F1076 1.57 1106 1.68 1137 1.78 1166 1.89 1194 1.99 1220 2.08 1248 2.19 2640 1004 1.44(b) 1036 1.55 1067 1.65 1098 1.77 1129 1.88 1158 1.99 1185 2.10 1214 2.22 - - - - 2880 1030 1.64 1061 1.75 1092 1.86 1123 1.98 1151 2.09 1181 2.22 - - - - - - - - 2-hp Oversized Motor & Drive Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 1-hp Fan Motor Heat (MBh) = 2.829 x Fan bhp+.4024. 2-hp Fan Motor Heat (MBh) = 3.000 x Fan bhp+.5000. 5. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horse power range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK84 and Belt AX36 required. (b) 1-hp Standard Motor & High Static Drive Kit (or 2-hp Oversized Motor & Drive) RT-PRCO23-EN 89 TRAME WF Evaporator Fan Performance Table 62. Belt drive evaporator fan performance - 6 tons standard efficiency - TSC072E3,4,W horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drivem 1-hp Standard Motor & Drive 1920 - - 1 580 0.33 641 0.41 692 0.47 738 0.54 783 0.63 827 0.71 870 0.79 912 0.88 951 0.96 2160 578 0.37 623 0.43 679 0.51 731 0.59 775 0.67 817 0.74 857 0.83 896 0.93 935 1.02 974 1.12 2400 633 0.49 673 0.56 718 0.63 769 0.72 814 0.82 855 0.90 893 0.98 929 1.08 965 1.18 999 1.29 2640 688 0.64 725 0.71 762 0.79 808 0.87 853 0.98 894 1.09 931 1.17 966 1.26 1000 1.36 1032 1.47(b) 2880 743 0.81 778 0.90 811 0.98 848 1.06 891 1.16 932 1.28 970 1.40 1004 1.49 1037 1.59 1068 1.69 1-hp Standard Motor & High Static Drive Kit (or 2-hp Oversized Motor) Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive 1-hp Standard Motor & High Static Drive Kit (or 2-hp Oversized Motor & Drive) 1920 990 1.05 1026 1.14 1062 1.24 1096 1.33 1130 1.43 1160 1.52 1190 1.61 1218 1.71 1247 1.80 1273 1.90 2160 1010 1.21 1047 1.31 1082 1.40 1116 1.50 1150 1.61 1182 1.71 1211 1.81 1242 1.92 1271 2.03 1 1298 2.14 2400 1035 1.39 1070 1.50 1104 1.60 1137 1.70 1168 1.81 1201 1.92 1232 2.03 1261 2.14 1291 2.26 - - 2640 1065 1.59 1097 1.71 1129 1.82 1161 1.93 1192 2.05 1223 2.16 1252 2.27 - - - - - - 2880 1099 1.80 1130 1.93 1159 2.05 1188 2.18 1217 2.30 - - - - - - - - 2-hp Oversized Motor & Drive 2-hp Oversized Motor & Field Supplied Drive() Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options accessories. 4. 1-hp Fan Motor Heat (MBh) = 2.829 x Fan bhp+.4024. 2-hp Fan Motor Heat (MBh) = 3.000 x Fan bhp+.5000. S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK84 and Belt AX36 required. (b) 2-hp Oversized Motor & Field Supplied Drive (c) Field Supplied Fan Sheave AK56 and Belt AX30. 90 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 63. Belt drive evaporator fan performance - 6 tons standard efficiency with gas heat - YSC072E3,4,W*L,M low & medium heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive 1920 - - - - 597 0.37 652 0.44 700 0.51 745 0.58 788 0.66 829 0.74 869 0.82 906 0.91 2160 - - 575 0.38 629 0.46 683 0.54 730 0.62 774 0.70 815 0.78 854 0.86 893 0.95 929 1.04 2400 561 0.41 615 0.49 664 0.57 714 0.65 762 0.74 805 0.83 844 0.92 882 1.01 918 1.10 954 1.20 2640 606 0.53 657 0.62 703 0.70 747 0.79 792 0.88 835 0.98 875 1.08 912 1.18 947 1.27 980 1.37 2880 651 0.67 699 0.77 743 0.85 785 0.94 825 1.05 867 1.15 906 1.26 943 1.37 978 1.47 1 1010 1.58 2-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive 1-hp Standard Motor & High Static Drive Kit (or 2-hp Oversized Motor & Drive) 1920 941 0.99 977 1.07 1009 1.15 1041 1.23 1073 1.32 1103 1.40 1132 1.49 1159 1.57 1187 1.66 1213 1.75 2160 964 1.13 997 1.23 1031 1.32 1061 1.41 1093 1.50 1123 1.60 1151 1.69 1179 1.78 1207 1.87 1234 1.97 2400 988 1.29 1020 1.39 1054 1.50 1085 1.60 1114 1.70 1143 1.80 1171 1.90 1200 2.01 1227 2.11 1254 2.21 2640 1014 1.47(b) 1046 1.58 1077 1.69 1107 1.80 1138 1.91 1166 2.02 1193 2.13 1222 2.25 - - - - 2880 1042 1.68 1073 1.79 1103 1.90 1132 2.02 1162 2.14 1190 2.26 - - - - - - - - 2-hp Oversized Motor & Drive Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 1-hp Fan Motor Heat (MBh) = 2.829 x Fan bhp+.4024. 2-hp Fan Motor Heat (MBh) = 3.000 x Fan bhp+.5000 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK84 and Belt AX36 required. (b) 1-hp Standard Motor & High Static Drive Kit (or 2-hp Oversized Motor & Drive) RT-PRCO23-EN 91 TRAMS WF Evaporator Fan Performance Table 64. Belt drive evaporator fan performance - 6 tons standard efficiency with gas heat - YSC072E3,4,W*L,M low & medium heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive 1920 -- 591 0.34 649 0.42 699 0.48 745 0.56 789 0.64 834 0.72 877 0.81 918 0.89 957 0.97 2160 587 0.38 633 0.44 690 0.52 740 0.61 784 0.68 825 0.76 865 0.85 904 0.95 943 1.04 981 1.13 2400 643 0.51 682 0.58 732 0.65 781 0.75 825 0.84 864 0.92 902 1.01 938 1.11 974 1.21 1010 1.32(b) 2640 700 0.66 736 0.74 775 0.81 822 0.90 866 1.01 906 1.11 942 1.20 976 1.29 1009 1.40 1042 1.51 2880 756 0.84 790 0.93 823 1.01 864 1.09 907 1.20 947 1.32 983 1.43 1017 1.53 1048 1.62 1080 1.73 2-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive 1-hp Standard Motor & High Static Drive Kit (or 2-hp Oversized Motor & Drive) 1920 996 1.06 1033 1.16 1067 1.25 1102 1.35 1134 1.44 1165 1.53 1195 1.63 1223 1.72 1251 1.82 1277 1.91 2160 1018 1.23 1054 1.32 1090 1.42 1123 1.52 1156 1.63 1188 1.73 1218 1.84 1247 1.94 1276 2.05 1304 2.16 2400 1044 1.42 1079 1.52 1112 1.62 1145 1.73 1177 1.83 1208 1.94 1240 2.06 1268 2.17 1298 2.29 - - 2640 1075 1.62 1107 1.74 1139 1.85 1170 1.96 1201 2.08 1232 2.19 - - - - - - - - 2880 1111 1.85 1140 1.97 1169 2.09 1200 2.22 - - - - - - - - - - 2-hp Oversized Motor & Drive 2-hp Oversized Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 1-hp Fan Motor Heat (MBh) = 2.829 x Fan bhp+.4024. 2-hp Fan Motor Heat (MBh) = 3.000 x Fan bhp+.5000. S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK84 and Belt AX36 required. (b) 1-hp Standard Motor & High Static Drive (or 2-hp Oversized Motor) (c) Field Supplied Fan Sheave AK56 and Belt AX30 required. 92 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 65. Belt drive evaporator fan performance - 6 tons standard efficiency with gas heat - YSC072E3AW*H high heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive 1920 -- 574 0.34 631 0.41 681 0.48 P27 0.55 771 0.63 814 0.71 853 0.79 892 0.87 928 0.95 2160 562 0.36 616 0.44 671 0.52 719 0.60 1 763 0.68 805 0.76 845 0.84 884 0.93 921 1.02 957 1.11 2400 612 0.48 662 0.56 711 0.65 759 0.74 802 0.83 842 0.91 879 1.00 916 1.09 951 1.19 986 1.29 2640 663 0.63 709 0.71 754 0.80 798 0.90 842 1.00 881 1.10 917 1.19 951 1.29 986 1.39 1018 1.49(b) 2880 715 0.80 758 0.88 799 0.98 840 1.08 880 1.19 920 1.30 955 1.41 990 1.51 1022 1.62 1053 1.72 2-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive 1-hp Standard Motor & High Static Drive Kit (or 2-hp Oversized Motor & Drive) 1920 963 1.04 997 1.12 1028 1.20 1061 1.28 1090 1.36 1119 1.45 1149 1.54 1177 1.63 1203 1.71 1229 1.80 2160 990 1.21 1023 1.30 1055 1.39 1086 1.48 1115 1.57 1144 1.66 1173 1.76 1200 1.85 1227 1.95 1253 2.04 2400 1019 1.39 1051 1.49 F1083 1.60 1113 1.70 1141 1.80 1171 1.90 1199 2.01 1225 2.10 1252 2.20 - - 2640 1050 1.59 1081 1.70 1111 1.81 1141 1.93 1170 2.04 1198 2.15 1226 2.27 - - - - - - 2880 1084 1.83 1114 1.94 1143 2.06 1172 2.18 1199 2.30 - - - - - - - - - - 2-hp Oversized Motor & Drive Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 1-hp Fan Motor Heat (MBh) = 2.829 x Fan bhp+.4024. 2-hp Fan Motor Heat (MBh) = 3.000 x Fan bhp+.5000 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK84 and Belt AX36 required. (b) 1-hp Standard Motor & High Static Drive Kit (or 2-hp Oversized Motor) RT-PRCO23-EN 93 TRAMS WF Evaporator Fan Performance Table 66. Belt drive evaporator fan performance - 6 tons standard efficiency with gas heat - YSC072E3,4,W*H high heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive 1920 565 0.31 627 727 0.52 772 0.61 816 0.69 859 0.77 902 0.86 942 0.94 981 1.03 2160 621 0.43 677 �80 774 0.66 816 0.74 856 0.83 895 0.93 934 1.02 973 1.11 1009 1.21(b) 2400 680 0.57 729 0.65 778 0.74 823 0.84 862 0.92 900 1.00 936 1.10 972 1.20 10 66 1.31 1041 1.41 2640 741 0.75 782 0.82 828 0.92 872 1.03 911 1.13 947 1.21 981 1.31 F1014 1.41 1048 1.53 1079 1.64 2880 802 0.95 837 1.04 880 1.13 921 1.24 960 1.36 995 1.47 1028 1.56 1060 1.66 1091 1.77 1122 1.89 2-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & High Static Drive Kit (or 2-hp Oversized Motor & Drive) 1920 1018 1.12 1054 1.21 1089 1.31 1122 1.40 1154 1.50 1184 1.59 1212 1.69 1241 1.78 1268 1.88 1293 1.97 2160 1045 1.30 1081 1.40 1114 1.50 1149 1.61 1181 1.71 1211 1.81 1241 1.92 1270 2.03 1298 2.13 1324 2.24 2400 1076 1.51 1110 1.62 1143 1.72 1176 1.83 1206 1.94 1238 2.05 1267 2.16 1297 2.28 - - - - 2640 1111 1.75 1144 1.87 1174 1.98 1205 2.09 1236 2.21 - - - - - - - - - - 2880 1151 2.02 1180 2.14 1209 2.27 - - - - - - - - - - - 2-hp Oversized Motor & Drive 2-hp Oversized Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 1-hp Fan Motor Heat (MBh) = 2.829 x Fan bhp+.4024. 2-hp Fan Motor Heat (MBh) = 3.000 x Fan bhp+.5000. S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK84 and Belt AX36 required. (b) 1-hp Standard Motor & High Static Drive Kit (or 2-hp Oversized Motor) (c) Field Supplied Fan Sheave AK56 and Belt AX30 required. 94 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 67. Belt drive evaporator fan performance - 71/2 tons standard efficiency - TSC092E3,4,W downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Low Static Drive Accessory Kit(a) 2400 - - 487 0.32 536 0.40 583 0.50 627 0.61 669 0.72 708 0.83 743 0.95 776 1.08 808 1.21 2700 - - 522 0.41 569 0.50 611 0.60 653 0.71 693 0.83 731 0.95 768 1.07 801 1.20 832 1.33 3000 - - 559 0.51 604 0.61 643 0.71 682 0.83 719 0.95 755 1.08 791 1.21 824 1.35 856 1.48 3300 3600 - - 599 0.63 601 0.68 640 0.79 639 0.74 678 0.86 713 0.97 748 1.09 783 1.23 815 1.37 675 0.89 713 1.02 748 1.14 780 1.26 811 1.40 844 1.55 2-hp Standard Motor 848 1.52 874 1.70 & Drive 880 1.66 904 1.86 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive 2400 839 1.34 868 1.48 898 1.61 926 1.75 953 1.89 980 2.04 1006 2.18 1032 2.34 1056 2.49 1080 2.64 2700 862 1.48 891 1.62 918 1.77 946 1.92 971 2.07 998 2.23 1023 2.38 1049 2.54 1074 2.70 1097 2.86 3000 886 1.63 915 1.78 942 1.93 968 2.09 994 2.25 1019 2.42 1044 2.59 1067 2.75 1092 2.93 1115 3.09 3300 910 1.81 939 1.96 967 2.12 993 2.28 1019 2.45 1043 2.62 1066 2.79 1091 2.98 1113 3.15 1136 3.34 3600 933 2.01 962 2.17 990 2.33 1016 2.49 1042 2.66 1067 2.84 1091 3.02 1114 3.21 1137 3.39 1158 3.58 Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.4750 5. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) BAYLSDR009A required RT-PRCO23-EN 95 TRAMS WF Evaporator Fan Performance Table 68. Belt drive evaporator fan performance - 71/2 tons standard efficiency - TSC092E3,4,W horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Low Static Drive Accessory Kit(a) 2400 502 0.36 552 0.43 603 0.52 653 0.63 707 0.75 754 0.88 792 0.99 825 1.09 857 1.19 886 1.30 2700 554 0.49 595 0.56 644 0.66 686 0.77 732 0.89 780 1.03 824 1.17 863 1.30 895 1.42 925 1.54 3000 605 0.65 644 0.73 684 0.82 726 0.94 765 1.06 806 1.20 849 1.35 891 1.51 929 1.66 962 1.80 3300 658 0.84 694 0.93 728 1.02 767 1.15 805 1.28 840 1.40 876 1.55 916 1.71 955 1.89 991 2.06 3600 711 1.07 746 1.18 776 1.27 809 1.38 846 1.52 880 1.66 912 1.80 943 1.95 980 2.13 1016 2.30 2-hp Standard Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 2400 913 1.40 941 1.51 966 1.61 991 1.71 1017 1.82 1040 1.92 1064 2.04 1087 2.14 1110 2.26 1132 2.37 2700 954 1.66 981 1.77 1006 1.89 1030 2.00 1054 2.12 1077 2.24 F1166 2.36 1121 2.47 1144 2.60 1164 2.71 3000 992 1.94 1019 2.07 1045 2.20 1069 2.32 1094 2.46 1116 2.58 1138 2.71 1160 2.84 1181 2.97 1202 3.10 3300 1025 2.22 1055 2.38 1082 2.53 1108 2.67 1132 2.82 1156 2.96 1178 3.11 1200 3.25 1221 3.39 - - 3600 1052 2.50 1085 2.69 1117 2.88 1144 3.05 1170 3.21 1193 3.37 - - - - - - - - 3-hp Oversized Motor & Drive Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 1 hp Fan Motor Heat (MBh) = 2.829 x Fan bhp+.4024. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) _ 2.900 x Fan bhp+.4750 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) BAYLSDR009A required 96 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 69. Belt drive evaporator fan performance - 71/2 tons standard efficiency -with gas heat YSC092E3,4,W*L,M low & medium heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive a 2400 - - - - - - 613 0.58 656 0.68 696 0.79 732 0.91 765 1.03 798 1.16 829 1.30 2700 - - - - 605 0.58 647 0.69 687 0.81 726 0.93 762 1.05 796 1.18 828 1.32 857 1.45 3000 - - 606 0.62 645 0.72 684 0.83 721 0.96 758 1.09 792 1.22 826 1.36 858 1.49 888 1.64 3300 609 0.66 650 0.77 688 0.89 723 1.00 758 1.13 792 1.27 825 1.41 857 1.56 888 1.70 918 1.85 3600 658 0.84 695 0.96 731 1.08 764 1.20 796 1.33 828 1.47 859 1.63 890 1.79 920 1.94 949 2.10 2-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 2400 858 1.43 888 1.57 917 1.71 945 1.85 971 1.99 998 2.14 1023 2.28 1048 2.44 1072 2.59 1095 2.75 2700 886 1.60 915 1.75 942 1.90 969 2.05 995 2.21 1020 2.36 1045 2.51 1069 2.67 1093 2.83 1117 3.00 3000 916 1.79 944 1.94 970 2.10 995 2.26 1020 2.43 1044 2.59 1069 2.76 1092 2.93 1116 3.10 1139 3.27 3300 947 2.01 974 2.16 1000 2.33 1026 2.50 1050 2.67 1073 2.84 1097 3.02 1119 3.20 1141 3.38 - - 3600 976 2.25 1004 2.42 1030 2.58 1056 2.76 1080 2.94 1103 3.12 1126 3.30 - - - - - - 3-hp Oversized Motor & Drive Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.4750. S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK79 and Belt AX38 required. RT-PRCO23-EN 97 TRAMS WF Evaporator Fan Performance Table 70. Belt drive evaporator fan performance - 71/2 tons standard efficiency with gas heat - YSC092E3,4,W*L,M low & medium heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive(a) 2400 -- 599 0.52 650 0.62 703 0.75 751 0.87 789 0.98 823 1.08 855 1.19 885 1.29 912 1.39 2700 604 0.58 651 0.68 694 0.79 741 0.91 789 1.06 832 1.19 868 1.32 900 1.44 931 1.56 959 1.68 3000 661 0.77 705 0.88 744 1.00 783 1.12 826 1.26 869 1.42 909 1.58 945 1.73 976 1.86 1004 1.99 3300 719 1.00 758 1.11 797 1.25 832 1.37 867 1.51 907 1.68 946 1.85 983 2.02 1017 2.18 1 1048 2.34 3600 779 1.28 813 1.39 8501.54 883 1.68 915 1.82 948 1.97 984 2.15 1020 2.3 3 1055 2.52 1088 2.71 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 2400 939 1.50 965 1.60 990 1.71 1014 1.81 1039 1.92 1063 2.03 1085 2.14 1108 2.25 1131 2.36 1154 2.49 2700 985 1.79 1010 1.91 1034 2.03 1058 2.14 1081 2.26 1104 2.38 1126 2.50 1148 2.62 1169 2.74 1190 2.86 3000 1031 2.12 1056 2.25 1081 2.39 1104 2.51 1127 2.65 1148 2.77 1169 2.90 1190 3.03 1210 3.16 1231 3.30 3300 1077 2.50 1102 2.64 1127 2.78 1151 2.93 1174 3.07 1194 3.21 1216 3.36 - - - - - - 3600 1120 2.89 1146 3.06 1172 3.22 1195 3.38 - - - - - - - - - - - - 3-hp Oversized Motor & Drive Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.4750 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK79 and Belt AX38 required. 98 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 71. Belt drive evaporator fan performance - 71/2 tons standard efficiency with gas heat - YSC092E3,4,W*H high heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive(a) 2400 - - - - - - 623 0.60 664 0.70 703 0.82 739 0.93 773 1.06 804 1.19 835 1.32 2700 - - - - 617 0.61 658 0.73 698 0.84 736 0.96 771 1.08 804 1.21 835 1.35 865 1.49 3000 - - 619 0.65 658 0.75 696 0.87 733 1.00 770 1.13 804 1.26 837 1.40 868 1.54 897 1.69 3300 625 0.70 666 0.82 702 0.93 737 1.05 771 1.19 805 1.33 838 1.47 870 1.62 900 1.76 929 1.91 3600 675 0.89 713 1.02 747 1.14 779 1.26 811 1.40 843 1.55 874 1.70 904 1.86 934 2.02 962 2.17 2-hp Standard Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 2400 864 1.46 895 1.60 923 1.74 951 1.88 977 2.02 1003 2.17 1028 2.32 1053 2.47 1078 2.63 1100 2.78 2700 894 1.64 921 1.79 948 1.94 974 2.09 1001 2.24 1027 2.40 1052 2.56 1076 2.72 1100 2.88 1124 3.05 3000 925 1.83 952 1.99 978 2.15 1004 2.32 1029 2.48 1052 2.65 1076 2.82 1100 2.99 1123 3.15 1146 3.33 3300 958 2.06 984 2.22 TO10 2.39 1035 2.56 1059 2.73 1082 2.91 1105 3.09 1128 3.28 - - - - 3600 990 2.33 1017 2.50 1043 2.66 1067 2.84 1091 3.02 1114 3.20 1137 3.39 - - - - - - 3-hp Oversized Motor & Drive Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.4750 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK79 and Belt AX38 required. RT-PRCO23-EN 99 TRAMS WF Evaporator Fan Performance Table72. Belt drive evaporator fan performance -71/2tons -standard efficiency with gas heat -YSC092E3,4,W*Hhigh heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive(a� 2400 -- 613 0.54 666 0.66 718 0.78 762 0.90 799 1.01 833 1.11 864 1.22 893 1.32 920 1.42 2700 621 0.61 667 0.72 710 0.83 759 0.97 804 1.10 846 1.24 880 1.36 911 1.48 941 1.60 968 1.72 3000 680 0.81 723 0.93 761 1.05 802 1.18 845 1.33 888 1.49 925 1.64 959 1.79 988 1.92 1016 2.05 3300 740 1.06 780 1.19 816 1.31 850 1.45 889 1.60 928 1.77 966 1.94 1002 2.11 1036 2.28 1 1063 2.42 3600 800 1.35 837 1.49 872 1.63 904 1.77 935 1.91 971 2.08 1007 2.27 2.45 1077 2.64 1108 2.83 2-hp Standard Motor & Drive 743 3-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive 2400 946 1.53 972 1.64 997 1.74 1022 1.84 1045 1.95 1069 2.06 1092 2.17 1115 2.28 1137 2.40 1160 2.52 2700 994 1.84 1019 1.95 1043 2.07 1066 2.18 1089 2.30 1112 2.42 1134 2.54 1155 2.66 1177 2.78 1197 2.90 3000 1043 2.18 1067 2.31 1091 2.44 1114 2.57 1137 2.70 1158 2.83 1178 2.96 1200 3.09 1220 3.22 1240 3.35 3300 1090 2.57 1116 2.72 1140 2.86 1162 3.00 1185 3.15 1206 3.29 1227 3.43 - - - - - - 3600 137 3.00 1163 3.17 1188 3.33 - - - - - - - - - - - - - - 1., For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.4750 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK79 and Belt AX38 required. 100 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 73. Belt drive evaporator fan performance - 81/2 tons standard efficiency - TSC102E3,4,W downf low airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive Accessory Kit(a) 2720 - - 539 0.44 584 0.53 626 0.64 668 0.76 708 0.88 746 1.00 781 1.12 814 1.26 845 1.40 3060 - - 583 0.58 626 0.68 665 0.78 703 0.90 740 1.04 775 1.17 810 1.30 843 1.44 875 1.58 3400 - - 628 0.72 669 0.84 706 0.96 741 1.08 775 1.211 809 1.36 841 1.51 873 1.65 904 1.81 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive 2720 874 1.54 904 1.69 930 1.84 958 2.00 983 2.14 1010 2.30 1035 2.46 1060 2.62 1084 2.78 1109 2.95 3060 905 1.73 933 1.89 960 2.05 986 2.20 1010 2.37 1035 2.54 1059 2.71 1083 2.89 1107 3.06 1131 3.24 3400 933 1.96 962 2.11 990 2.27 1016 2.44 1041 2.62 1065 2.79 1089 2.97 1112 3.15 1134 3.34 - - 3740 964 2.22 992 2.39 1018 2.55 1045 2.72 1071 2.90 1095 3.08 1118 3.26 1141 3.45 - - - - 4080 995 2.51 1023 2.69 1048 2.86 1075 3.05 1100 3.23 1124 3.41 - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 1 hp Fan Motor Heat (MBh) = 2.829 x Fan bhp+.4024. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) _ 2.900 x Fan bhp+.4750 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) BAYLSDR009A Required. RT-PRCO23-EN 101 TRAMS WF Evaporator Fan Performance Table 74. Belt drive evaporator fan performance - 81/2 tons standard efficiency - TSC102E3,4,W horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive Accessory Kit(a) 2720 570 0.52 612 0.60 660 0.71 703 0.81 751 0.95 798 1.09 841 1.23 877 1.36 909 1.48 939 1.60 3060 631 0.72 667 0.80 709 0.91 750 1.03 788 1.15 830 1.29 873 1.45 914 1.62 951 1.77 983 1.92 3400 692 0.96 726 1.05 760 1.15 800 1.29 836 1.42 870 1.56 907 1.71 945 1.88 984 2.06 1020 2.24 3740 754 1.26 786 1.36 815 1.46 850 1.59 886 1.74 918 1.88 949 2.03 980 2.19 1015 2.37 1052 2.57 4080 817 1.61 848 1.72 874 1.83 903 1.95 935 2.10 968 2.26 F9698 2.42 1026 2.58 1054 2.75 1085 2.94 2-hp Standard Motor & Drive 3-hp Standard Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive 2720 967 1.72 994 1.84 1018 1.96 1042 2.07 1066 2.19 1089 2.31 1112 2.43 1134 2.55 1155 2.67 1176 2.79 3080 1012 2.06 1039 2.19 1065 2.32 1090 2.46 1113 2.59 1136 2.73 1158 2.86 1179 2.99 1199 3.12 1220 3.26 3400 1052 2.41 1083 2.58 1109 2.73 1135 2.88 1159 3.04 1183 3.19 1204 3.33 - - - - - - 3740 1086 2.77 1119 2.96 1149 3.15 1178 3.34 - - - - - - - - - - - - 4080 1117 3.14 1151 3.36 - - - - - - - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 1 hp Fan Motor Heat (MBh) = 2.829 x Fan bhp+.4024. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) _ 2.900 x Fan bhp+.4750 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) BAYLSDR009A required. 102 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 75. Belt drive evaporator fan performance - 81/2 tons standard efficiency with gas heat - YSC102E3,4,W*L low heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive(a) 2720 - - - - 621 0.62 662 0.74 703 0.86 741 0.98 777 1.11 810 1.24 841 1.38 871 1.52 3060 587 0.58 630 0.69 668 0.79 707 0.92 743 1.05 779 1.18 814 1.32 846 1.45 878 1.60 907 1.75 3400 643 0.77 683 0.89 718 1.00 753 1.13 787 1.26 820 1.41 853 1.56 884 1.71 915 1.86 944 2.02 3740 699 0.99 736 1.12 770 1.25 802 1.38 833 1.52 864 1.67 894 1.83 925 2.00 953 2.16 1 982 2.33 4080 757 1.26 790 1.40 823 1.55 853 1.69 882 1.83 910 1.98 938 2.15 967 2.32 994 2.50 1021 2.68 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive 2720 900 1.67 927 1.82 954 1.97 980 2.12 1006 2.28 1032 2.44 1057 2.60 1082 2.76 1105 2.92 1129 3.09 3060 936 1.90 962 2.06 989 2.22 1014 2.39 1039 2.56 1062 2.73 1085 2.90 1109 3.07 1133 3.25 1155 3.43 3400 973 2.17 999 2.34 1025 2.51 1050 2.68 1074 2.86 1097 3.04 1120 3.22 1142 3.41 - - - - 3740 1010 2.50 1036 2.66 1062 2.84 1087 3.01 1110 3.19 1134 3.39 - - - - - - - - 4080 1047 2.86 1073 3.04 1098 3.22 1123 3.40 F- - - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.4750 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK79 and Belt AX38 required. RT-PRCO23-EN 103 TRAMS WF Evaporator Fan Performance Table 76. Belt drive evaporator fan performance - 81/2 tons standard efficiency with gas heat - YSC102E3,4,W*L low heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive(a) 2-hp Standard Motor & Drive 2720 622 0.62 669 0.73 711 0.84 760 0.97 807 1.12 849 1.26 884 1.38 915 1.50 944 1.62 972 1.74 3060 688 0.85 732 0.97 770 1.09 809 1.22 853 1.38 895 1.54 934 1.70 968 1.85 998 1.99 1026 2.13 3400 756 1.14 795 1.27 832 1.40 866 1.54 901 1.69 941 1.86 979 2.04 1015 2.22 1049 2.40 1079 2.56 3740 824 1.49 859 1.62 895 1.78 926 1.92 957 2.07 990 2.24 1025 2.42 1061 2.62 1095 2.82 1127 3.02 4080 893 1.90 925 2.05 958 2.21 988 2.37 1017 2.53 1046 2.70 1075 2.88 1108 3.08 1140 3.29 3-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive 2720 998 1.86 1024 1.98 1047 2.10 1071 2.22 1094 2.33 1115 2.45 1138 2.57 1159 2.69 1181 2.82 1201 2.94 3060 1053 2.26 1078 2.39 1102 2.53 1125 2.66 1146 2.79 1169 2.93 1190 3.06 1210 3.19 1230 3.32 1250 3.45 3400 1106 2.71 1131 2.86 1156 3.02 1179 3.16 1201 3.31 1223 3.45 - - - - - - - - 3740 1158 3.21 1185 3.39 - - - - - - - - - - - - - - - - 4080 - - - - - - - - - - - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.4750. S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK79 and Belt AX38 required. 104 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 77. Belt drive evaporator fan performance - 81/2 tons with gas heat - YSC102E3,4,W*M medium heat downf low airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive(a) 2720 - - - - 623 0.63 664 0.75 704 0.87 742 0.99 778 1.11 811 1.24 842 1.38 872 1.53 3060 589 0.58 632 0.69 670 0.80 709 0.92 745 1.06 781 1.19 815 1.32 848 1.46 880 1.60 909 1.75 3400 645 0.77 685 0.89 721 1.01 755 1.13 789 1.27 822 1.42 854 1.57 886 1.72 916 1.87 945 2.02 3740 702 1.00 739 1.14 772 1.26 804 1.39 836 1.53 867 1.69 897 1.85 926 2.01 956 2.18 1 984 2.34 4080 759 1.27 793 1.42 826 1.56 856 1.70 884 1.84 913 2.00 941 2.16 969 2.34 996 2.52 1024 2.70 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive 2720 900 1.67 928 1.82 955 1.98 982 2.14 1008 2.29 1033 2.45 1057 2.60 1083 2.77 1107 2.94 1129 3.10 3060 936 1.91 964 2.07 989 2.23 1 1015 2.39 1039 2.56 1063 2.73 1088 2.92 1111 3.09 1134 3.26 1157 3.44 3400 974 2.18 1001 2.35 1027 2.52 1051 2.69 1075 2.87 1098 3.05 1121 3.23 1144 3.42 - - - - 3740 1011 2.50 1038 2.68 1064 2.85 1089 3.03 1113 3.22 1135 3.40 - - - - - - - - 4080 1050 2.87 1076 3.05 1101 3.24 1126 3.43 - - - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.4750 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK79 and Belt AX38 required. RT-PRCO23-EN 105 TRAMS WF Evaporator Fan Performance Table 78. Belt drive evaporator fan performance - 81/2 tons with gas heat - YSC102E3,4,W*M medium heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive(a) 2720 625 0.62 671 0.73 714 0.84 763 0.98 809 1.13 851 1.27 885 1.39 917 1.51 946 1.63 974 1.75 3060 691 0.86 734 0.98 772 1.10 812 1.23 856 1.39 897 1.55 936 1.71 970 1.86 1001 2.00 1028 2.14 3400 759 1.15 798 1.28 835 1.41 868 1.55 904 1.70 943 1.87 982 2.05 1019 2.23 1052 2.41 1082 2.57 3740 827 1.50 863 1.64 898 1.79 930 1.94 960 2.09 994 2.26 1029 2.44 1064 2.64 1098 2.84 1130 3.03 4080 897 1.92 929 2.07 962 2.23 2.39 1021 2.55 1049 2.72 1079 2.90 1112 3.10 1144 3.31 �992 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive 2720 1000 1.87 1025 1.99 1048 2.10 1072 2.22 1095 2.34 1117 2.46 1139 2.58 1161 2.70 1182 2.82 1203 2.95 3060 1054 2.27 1080 2.41 1103 2.53 1126 2.67 1149 2.80 1170 2.93 1192 3.07 1211 3.20 1231 3.33 - - 3400 1108 2.73 1134 2.88 1158 3.03 1181 3.17 1204 3.33 - - - - - - - - - - 3740 1160 3.23 1187 3.41 - - - - - - - - - - - - - - - - 4080 - - - - - - - - - - - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.4750 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK79 and Belt AX38 required. 106 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 79. Belt drive evaporator fan performance - 81/2 tons standard efficiency with gas heat - YSC102E3,4,W*H high heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive(a) 2720 -- 590 0.55 633 0.66 674 0.77 713 0.89 750 1.01 786 1.14 818 1.28 850 1.42 879 1.56 3060 602 0.62 643 0.72 682 0.83 719 0.�11 791 1.23 825 1.36 857 1.50 889 1.65 917 1.80 3400 660 0.82 698 0.94 733 1.05 767 1. 834 1.48 866 1.62 897 1.77 927 1.92 956 2.08 3740 718 1.06 754 1.19 1 787 1.32 818 1.45 849 1.60 880 1.76 910 1.92 939 2.08 968 2.24 996 2.41 4080 777 1.35 811 1.49 841 1.63 870 1.77 899 1.92 928 2.08 956 2.26 983 2.43 1011 2.61 1037 2.79 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive 2720 907 1.71 934 1.86 960 2.01 987 2.17 1014 2.33 1039 2.48 1063 2.64 1088 2.81 1112 2.97 1134 3.13 3060 945 1.95 971 2.11 997 2.28 1022 2.45 1047 2.62 1070 2.79 1094 2.96 1117 3.14 1141 3.31 - - 3400 985 2.24 1010 2.40 1036 2.58 1060 2.76 1084 2.93 1106 3.11 1130 3.31 - - - - - - 3740 1023 2.58 1049 2.75 1075 2.93 1099 3.11 1122 3.29 - - - - - - - - - - 4080 1063 2.96 1089 3.15 1114 3.34 - - - - - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.4750 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK79 and Belt AX38 required. RT-PRCO23-EN 107 TRAMS WF Evaporator Fan Performance Table 80. Belt drive evaporator fan performance - 81/2 tons standard efficiency with gas heat - YSC102E3,4,W*H high heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Field Supplied Low Static Drive(a) 2-hp Standard Motor & Drive 2720 640 0.66 684 0.77 729 0.89 778 1.03 823 1.17 863 1.31 896 1.43 926 1.55 955 1.67 982 1.79 3060 709 0.91 750 1.03 788 1.15 829 1.29 872 1.45 913 1.61 950 1.77 983 1.92 1011 2.05 1038 2.19 3400 778 1.21 817 1.35 851 1.48 885 1.62 924 1.78 963 1.96 1000 2.14 1035 2.30 1067 2.49 1095 2.65 3740 848 1.58 885 1.73 917 1.88 948 2.03 979 2.18 1014 2.36 1050 2.56 1084 2.76 1118 2.96 1148 3.15 4080 919 2.02 952 2.18 984 2.35 1012 2.50 1041 2.67 1070 2.84 1102 3.04 1135 3.25 - - - - 3-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 2-hp Standard Motor & Drive 3-hp Oversized Motor & Drive 2720 1007 1.90 1032 2.02 1056 2.14 1079 2.26 1101 2.38 1124 2.50 1146 2.62 1167 2.74 1189 2.86 1209 2.98 3060 1064 2.32 1090 2.46 1113 2.59 1135 2.72 1157 2.85 1178 2.98 1199 3.12 1220 3.26 1240 3.39 - - 3400 1121 2.80 1146 2.95 1170 3.10 1193 3.25 1215 3.40 - - - - - - - - - - 3740 1177 3.34 - - - - - - - - - - - - - - - - - - 4080 - - - - - - - - - - - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 2-hp Fan Motor Heat (MBh) = 2.000 x Fan bhp+.5000. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.4750 S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK79 and Belt AX38 required. 108 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 81. Belt drive evaporator fan performance - 10 tons standard efficiency - TSC120E3,4,W downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Standard Motor & Low Static Drive Accessory Kit(a) 3200 576 0.57 618 0.67 659 0.79 697 0.90 734 1.03 770 1.17 804 1.31 839 1.45 871 1.60 901 1.74 3600 638 0.78 675 0.89 714 1.02 749 1.14 782 1.27 815 1.41 847 1.57 879 1.73 909 1.89 939 2.04 4000 701 1.04 734 1.16 768 1.30 803 1.44 834 1.58 863 1.72 894 1.87 923 2.04 952 2.21 979 2.39 4400 764 1.36 795 1.49 825 1.63 857 1.79 888 1.95 916 2.10 943 2.25 970 2.41 997 2.59 1024 2.78 4800 828 1.74 857 1.88 884 2.02 942 2.36 970 2.53 996 2.70 1021 2.86 1045 3.03 1070 3.22 [9�. 3-hp Standard Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Oversized Motor & Drive 3200 931 1.89 959 2.06 986 2.22 1012 2.39 1037 2.56 1061 2.74 1084 2.91 1108 3.09 1131 3600 969 2.21 997 2.37 1024 2.54 1050 2.72 1074 2.89 1098 3.08 1122 3.27 1145 3.46 1166 4000 1007 2.57 1034 2.74 1062 2.93 1087 3.11 1112 3.29 1136 3.47 1159 3.66 1182 3.86 1204 4400 1050 2.97 1075 3.17 1101 3.36 1126 3.55 1150 3.75 1173 3.94 1198 4.15 1219 4.34 1241 4800 1095 3.42 1119 3.62 1143 3.83 1166 4.05 1189 4.26 1212 4.47 1235 4.68 1258 4.90 1280 5-hp Oversized Motor & Drive 3.28 1 1153 3.46 3.65 1188 3.85 4.07 1226 4.28 4.54 1264 4.77 5.12 1300 5.32 Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.475. 5-hp Fan Motor Heat (MBh) = 2.950 x Fan bhp+.470. S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) BAYLSDR010A required. RT-PRCO23-EN 109 TRAMS WF Evaporator Fan Performance Table 82. Belt drive evaporator fan performance - 10 tons standard efficiency - TSC120E3,4,W horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Standard Motor & Low Static Drive Accessory Kit(a) 3200 671 0.85 706 0.93 748 1.06 787 1.19 824 1.32 864 1.47 906 1.64 946 1.81 983 1.97 1015 2.13 3600 746 1.18 777 1.27 811 1.39 849 1.54 883 1.68 916 1.82 950 1.98 987 2.16 1024 2.35 1060 2.55 4000 822 1.59 850 1.70 879 1.81 1 912 1.95 946 2.12 977 2.28 1006 2.43 1035 2.60 1067 2.79 1101 2.99 4400 898 2.09 925 2.21 950 2.32 977 2.46 1008 2.63 1039 2.81 1067 2.98 1094 3.16 1121 3.33 1147 3.52 4800 974 2.69 1000 2.83 1023 2.95 1046 3.07 1072 3.23 1101 3.42 1130 3.62 1156 3.81 1181 4.00 1206 4.19 3-hp Standard Motor & Drive 5-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Standard Motor & Drive 3200 1044 2.28 1072 2.42 1097 2.57 1122 2.71 1145 2.84 1168 2.99 1189 3.12 1210 3.27 1231 3.41 1250 3.54 3600 1093 2.74 1124 2.92 1151 3.09 1176 3.25 1201 3.42 1224 3.58 1246 3.74 1268 3.90 1289 4.06 1308 4.20 4000 1135 3.21 1167 3.42 1198 3.63 1227 3.84 1254 4.05 1278 4.23 1301 4.41 1323 4.60 1344 4.77 1365 4.95 4400 1177 3.73 1207 3.96 1239 4.19 1268 4.42 1297 4.67 1324 4.90 1351 5.12 1376 5.35 1398 5.56 1420 5.75 4800 1229 4.39 1254 4.59 1282 4.83 1310 5.07 1338 5.32 1365 5.58 - - - - - - - - 5-hp Oversized Motor & Drive Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.475. 5-hp Fan Motor Heat (MBh) = 2.950 x Fan bhp+.470. S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) BAYLSDR010A required. 110 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 83. Belt drive evaporator fan performance - 10 tons standard efficiency with gas heat - YSC120E3,4,W*L,M low & medium heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Standard Motor & Field Supplied Low Static Drive(a) 3200 - - - - - - 743 1.06 779 1.20 814 1.35 847 1.49 879 1.63 910 1.78 938 1.93 3600 - - 735 1.10 768 1.22 802 1.36 834 1.50 866 1.66 897 1.82 927 1.98 957 2.14 985 2.30 4000 767 1.29 802 1.44 833 1.58 863 1.71 892 1.87 922 2.04 951 2.21 979 2.39 1006 2.56 1034 2.74 4400 837 1.69 869 1.85 899 2.00 926 2.15 953 2.31 980 2.48 1007 2.66 1033 2.85 1059 3.04 1085 3.24 4800 908 2.16 937 2.33 965 2.50 991 2.67 1017 2.83 1041 3.00 1066 3.19 1090 3.38 1115 3.59 1139 3.80 3-hp Standard Motor & Drive 5-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Standard Motor & Drive 3200 966 2.10 992 2.26 1018 2.43 1042 2.60 1066 2.78 1091 2.96 1114 3.15 1136 3.33 1159 3.51 1182 3.70 3600 1013 2.47 1039 2.64 1065 2.82 1089 3.00 1113 3.19 1135 3.38 1 1157 3.56 1179 3.76 1201 3.97 1221 4.16 4000 1060 2.92 1086 3.10 1111 3.28 1135 3.47 1159 3.66 1182 3.86 1203 4.05 1224 4.26 1246 4.47 1266 4.68 4400 1110 3.4.31F11113344 3.62 1159 3.82 1183 4.02 1205 4.22 1229 4.43 1251 4.64 1272 4.84 1292 5.05 1313 5.27 4800 1162 4.01 1185 4.22 1209 4.44 1231 4.64 1253 4.86 1276 5.07 1298 5.30 1319 5.51 1338 5.73 5-hp Oversized Motor & Drive Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.475. 5-hp Fan Motor Heat (MBh) = 2.950 x Fan bhp+.470. S. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Motor Sheave 1VM50 x 7/8 inch, Fan Sheave AK89, and Belt AX40 required. RT-PRCO23-EN 111 TRAMS WF Evaporator Fan Performance Table 84. Belt drive evaporator fan performance - 10 tons standard efficiency with gas heat - YSC120E3,4,W*L,M low & medium heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Standard Motor & Field Supplied Low Static Drive(a) 3-hp Standard Motor & Drive 3200 -- 777 1.15 814 1.28 853 1.42 895 1.59 936 1.76 973 1.93 1008 2.09 1037 2.24 1064 2.38 3600 819 1.42 857 1.57 890 1.71 922 1.85 957 2.02 994 2.20 1032 2.39 1067 2.58 1099 2.77 1131 2.96 4000 902 1.91 936 2.07 968 2.23 998 2.39 1027 2.55 1058 2.73 1091 2.93 1124 3.14 1158 3.36 1189 3.57 4400 986 2.50 1016 2.68 1047 2.86 1075 3.03 1101 3.20 1128 3.39 1 1155 3.58 1186 3.80 1217 4.03 1246 4.25 4800 1070 3.22 1098 3.40 3.60 1153 3.79 1178 3.98 1203 4.17 1227 4.37 1251 4.57 1279 4.80 1307 5.05 [1127 5-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Standard Motor & Drive 5-hp Oversized Motor & Drive 3200 1090 2.53 1115 2.67 1139 2.81 1161 2.95 1183 3.09 1205 3.23 1225 3.37 1246 3.51 1265 3.65 1284 3.78 3600 1157 3.13 1181 3.29 1205 3.45 1228 3.61 1250 3.77 1272 3.93 1293 4.09 1312 4.24 1331 4.40 1351 4.56 4000 1218 3.78 1246 3.99 1271 4.18 1294 4.36 1317 4.55 1338 4.72 1360 4.91 1379 5.07 1398 5.25 1418 5.43 4400 1276 4.49 1304 4.73 1333 4.97 1359 5.20 1383 5.42 1405 5.62 - - - - - - - - 4800 1336 5.30 1363 5.56 - - - - - - - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.475. 5-hp Fan Motor Heat (MBh) = 2.950 x Fan bhp+.470. 5. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Motor Sheave 1VM50 x 7/8 inch, Fan Sheave AK89, and Belt AX40 required. 112 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 85. Belt drive evaporator fan performance - 10 tons with standard efficiency gas heat - YSC120E3,4,W*H high heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Standard Motor & Field Supplied Low Static Drive(a) 3200 - - - - 1 739 1.05 774 1.19 809 1.33 843 1.47 874 1.61 905 1.76 935 1.92 963 2.08 3600 738 1.11 772 1.23 805 1.37 838 1.52 869 1.68 900 1.84 930 2.00 960 2.16 988 2.32 1016 2.49 4000 813 1.49 844 1.63 873 1.77 903 1.93 932 2.10 961 2.27 989 2.45 1017 2.63 1043 2.80 1070 2.98 4400 889 1.95 917 2.10 944 2.25 971 2.42 998 2.59 1024 2.78 1050 2.97 1076 3.17 1101 3.37 1126 3.56 4800 964 2.50 991 2.66 1016 2.83 1040 3.00 1065 3.18 1090 3.38 1114 3.58 1138 3.79 1161 4.00 1184 4.22 3-hp Standard Motor & Drive 5-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Standard Motor & Drive 5-hp Oversized Motor & Drive 3200 989 2.24 1015 2.41 1039 2.58 1064 2.76 1087 2.93 1111 3.12 1133 3.30 1156 3.48 1179 3.68 1200 3.85 3600 1042 2.66 1067 2.84 1091 3.02 1115 3.21 1138 3.40 1160 3.59 1181 3.78 1203 3.98 1224 4.19 1244 4.39 4000 1095 3.17 1120 3.35 1 1145 3.54 1167 3.73 1190 3.93 1212 4.14 1233 4.35 1253 4.55 1273 4.76 1293 4.97 4400 1150 3.75 1174 3.95 1197 4.15 1221 4.36 1243 4.56 1265 4.77 1285 4.97 1306 5.20 1326 5.42 1345 5.65 4800 1208 4.42 1231 4.64 1253 4.86 1275 5.07 1297 5.29 1317 5.50 1338 5.72 - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.475. 5-hp Fan Motor Heat (MBh) = 2.950 x Fan bhp+.470. 5. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Motor Sheave 1VM50 x 7/8 inch, Fan Sheave AK89, and Belt AX40 required. RT-PRCO23-EN 113 TRAMS WF Evaporator Fan Performance Table 86. Belt drive evaporator fan performance - 10 tons standard efficiency with gas heat - YSC120E3,4,W*H high heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Standard Motor & Field Supplied Low Static Drive(a) 3-hp Standard Motor & Drive 3200 785 1.18 821 1.31 861 1.46 903 1.62 944 1.80 981 1.96 1014 2.12 1043 2.27 1070 2.41 1095 2.55 3600 874 1.64 907 1.78 939 1.93 977 2.11 1014 2.30 1050 2.49 1084 2.69 1115 2.87 1144 3.05 1169 3.21 4000 964 2.21 994 2.37 1023 2.53 1053 2.71 1087 2.91 1121 3.12 1154 3.33 1185 3.55 1215 3.76 1242 3.96 4400 1055 2.91 1082 3.08 1109 3.25 1135 3.43 1164 3.64 1194 3.86 1225 4.09 1255 4.32 1284 4.56 1312 4.79 4800 1146 3.74 1171 3.92 1196 4.11 1220 4.31 1244 4.51 1271 4.73 1298 4.97 1327 5.22 1354 5.47 1382 5.74 5-hp Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 3-hp Standard Motor & Drive 5-hp Oversized Motor & Drive 3200 1120 2.70 1143 2.84 1166 2.98 1188 3.12 1208 3.25 1229 3.39 1249 3.53 1269 3.67 1289 3.82 1308 3.96 3600 1194 3.37 1217 3.53 1240 3.69 1262 3.85 1282 4.01 1303 4.17 1322 4.32 1341 4.48 1361 4.64 1378 4.79 4000 1269 4.16 1292 4.34 1314 4.52 1335 4.70 1356 4.88 1377 5.06 1397 5.24 1415 5.41 - - - - 4400 1339 5.02 1365 5.25 1388 5.47 1410 5.67 - - - - - - - - - - 4800 - - - - - - - - - - - - - - - - - - - - Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 105, p. 133. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Refer to Table 114, p. 135 to determine additional static pressure drop due to other options/accessories. 4. 3-hp Fan Motor Heat (MBh) = 2.900 x Fan bhp+.475. 5-hp Fan Motor Heat (MBh) = 2.950 x Fan bhp+.470. 5. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Motor Sheave 1VM50 x 7/8 inch, Fan Sheave AK89, and Belt AX40 required 114 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 87. Belt drive evaporator fan performance - 3 tons high efficiency - THC036E3,E4,EW downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 960 - - - - 614 0.17 683 0.22 742 0.27 795 0.32 845 0.37 891 0.42 935 0.47 977 0.53 1080 - - 561 0.15 635 0.20 704 0.25 765 0.30 818 0.36 868 0.42 913 0.47 957 0.53 998 0.59 1200 - - 592 0.18 658 0.23 725 0.29 786 0.35 842 0.41 891 0.47 936 0.53 979 0.59 1019 0.66 1320 555 0.17 625 0.22 686 0.27 747 0.33 807 0.39 862 0.46 914 0.53 959 0.59 1002 0.66 1043 0.73 1440 592 0.21 658 0.27 717 0.32 772 0.38 828 0.44 882 0.51 933 0.58 980 0.66 1025 0.73 1065 0.80 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1016 0.59 1054 0.65 1089 0.70 1124 0.76 1155 0.82 1080 1036 0.65 1075 0.72 1111 0.78 1146 0.84 1180 0.91 1200 1058 0.72 1095 0.78 1131 0.85 1167 0.92 1201 0.99 1320 1082 0.80 1119 0.87 1153 0.94 1188 1.01 1221 1.08 1440 1104 0.88 1141 0.95 1176 1.03 1211 1.10 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK71x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK410/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 115 TRAMS WF Evaporator Fan Performance Table 88. Belt drive evaporator fan performance - 3 tons high efficiency - THC036E3,E4,EW horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drivem 1-hp Standard Motor & Drive(b) 960 - - 552 0.12 626 0.16 689 0.20 748 0.25 802 0.30 852 0.35 898 0.39 942 0.44 982 0.49 1080 - - 576 0.14 654 0.19 716 0.24 772 0.29 825 0.34 874 0.39 921 0.45 964 0.50 1005 0.55 1200 - - 600 0.17 681 0.23 744 0.28 799 0.33 850 0.39 898 0.44 943 0.50 987 0.56 1028 0.62 1320 554 0.16 627 0.20 705 0.27 773 0.33 828 0.38 877 0.44 923 0.50 967 0.56 1010 0.62 1052 0.69 1440 590 0.20 657 0.24 728 0.30 797 0.37 855 0.44 904 0.50 950 0.56 993 0.63 1034 0.69 1074 0.76 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1020 0.54 1057 0.59 1092 0.64 1126 0.69 1158 0.74 1080 1045 0.61 1082 0.67 1116 0.72 1151 0.77 1183 0.83 1200 1067 0.68 1104 0.74 1141 0.80 1174 0.86 1207 0.92 1320 1091 0.75 1127 0.82 1163 0.88 1198 0.95 1230 1.02 1440 1112 0.83 1150 0.90 1186 0.97 1221 1.04 1254 1.11 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK71x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK410/4" required. Field Supplied Belt may be necessary. 116 RT-PRCO23-EN qW TRANE Evaporator Fan Performance Table 89. Belt drive evaporator fan performance - 3 tons high efficiency - YHCO36E3,E4,EW*L,1Vl low & medium gas heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 960 - - - - 605 0.15 671 0.19 730 0.23 784 0.27 835 0.31 881 0.36 924 0.41 965 0.45 1080 - - 563 0.14 630 0.17 693 0.22 751 0.26 804 0.31 854 0.35 901 0.40 946 0.46 986 0.50 1200 - - 596 0.17 659 0.21 718 0.25 773 0.30 825 0.35 875 0.40 921 0.45 964 0.51 1005 0.56 1320 555 0.16 629 0.20 689 0.25 745 0.29 797 0.34 848 0.40 897 0.45 941 0.51 984 0.56 1026 0.62 1440 593 0.20 663 0.25 721 0.29 775 0.34 824 0.39 873 0.45 919 0.51 963 0.57 1006 0.63 1046 0.69 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1004 0.50 1039 0.55 1073 0.59 1105 0.64 1137 0.69 1080 1025 0.56 1063 0.61 1098 0.66 1132 0.72 1163 0.77 1200 1046 0.62 1082 0.67 1119 0.73 1153 0.79 1187 0.85 1320 1064 0.68 1103 0.74 1139 0.80 1174 0.86 1207 0.93 1440 1085 0.75 1123 0.81 1159 0.88 1193 0.94 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK710/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 117 TRAMS WF Evaporator Fan Performance Table 90. Belt drive evaporator fan performance - 3 tons high efficiency - YHC036E3,E4,EW*L,M low & medium gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 960 - - - - 613 0.15 679 0.20 736 0.24 788 0.28 837 0.32 886 0.37 930 0.42 973 0.47 1080 - - 561 0.14 636 0.18 702 0.23 761 0.28 812 0.32 860 0.37 904 0.42 947 0.47 991 0.52 1200 - - 589 0.16 661 0.21 726 0.26 784 0.31 836 0.37 884 0.42 929 0.47 970 0.52 1011 0.58 1320 - - 619 0.20 1440 585 0.19 651 0.24 687 0.25 715 0.29 750 0.30 807 0.36 859 0.41 F775 0.35 831 0.40 883 0.47 909 0.47 953 0.53 995 0.59 931 0.53 976 0.59 1019 0.66 1034 0.65 1058 0.72 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1014 0.53 1051 0.58 1087 0.63 1121 0.68 1155 0.74 1080 1031 0.58 1071 0.64 1108 0.69 1142 0.75 1177 0.81 1200 1049 0.63 1087 0.69 1124 0.75 1161 0.82 1195 0.88 1320 1071 0.70 1107 0.76 1143 0.82 1178 0.89 1213 0.96 1440 1095 0.78 1130 0.84 1166 0.91 1199 0.97 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK710/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK410/4" required. Field Supplied Belt may be necessary. 118 RT-PRCO23-EN qW TRANE Evaporator Fan Performance Table 91. Belt drive evaporator fan performance - 3 tons high efficiency - YHC036E3,E4,EW*H high gas heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 960 - - - - 609 0.15 671 0.19 730 0.24 785 0.28 835 0.33 881 0.37 924 0.42 966 0.47 1080 - - 572 0.14 638 0.18 697 0.23 752 0.27 805 0.32 855 0.37 900 0.42 945 0.47 986 0.53 1200 - - 606 0.18 668 0.22 725 0.26 778 0.31 827 0.36 876 0.42 922 0.47 964 0.52 1007 0.58 1320 573 0.17 641 0.22 700 0.26 754 0.31 805 0.36 853 0.41 898 0.47 942 0.53 985 0.59 1026 0.65 1440 613 0.21 677 0.27 733 0.31 F786 0.36 835 0.42 881 0.47 925 0.53 966 0.59 1007 0.65 1047 0.71 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 960 1004 0.52 1041 0.58 1076 0.63 1109 0.68 1142 0.73 1080 1026 0.58 1063 0.64 1098 0.69 1133 0.75 1165 0.81 1200 1046 0.64 1083 0.70 1120 0.76 1154 0.82 1187 0.88 1320 1065 0.71 1103 0.77 1139 0.83 1175 0.90 1207 0.96 1440 1086 0.78 1123 0.84 1160 0.91 1194 0.98 1227 1.05 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK71x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 119 TRAMS WF Evaporator Fan Performance Table 92. Belt drive evaporator fan performance - 3 tons high efficiency - YHC036E3,E4,EW*H high gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 960 - - - - 621 0.15 685 0.20 745 0.24 799 0.29 849 0.33 894 0.38 936 0.42 975 0.47 1080 - - 580 0.14 649 0.19 711 0.23 768 0.28 821 0.32 871 0.38 917 0.43 960 0.48 1000 0.53 1200 - - 613 0.18 679 0.22 738 0.27 793 0.32 845 0.37 892 0.42 939 0.48 982 0.53 1024 0.59 1320 574 0.17 647 0.22 710 0.26 767 0.31 820 0.37 870 0.42 917 0.48 962 0.53 1004 0.59 1046 0.66 1440 612 0.21 682 0.26 742 0.31 797 0.37 849 0.42 897 0.48 943 0.54 986 0.60 1028 0.66 1068 0.72 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(h) 960 1012 0.52 1048 0.57 108�O6 1116 0.67 1148 0.72 1080 1039 0.59 1075 0.64 1101142 0.74 1173 0.80 1200 1063 0.65 1100 0.71 1131168 0.83 1199 0.88 1320 1085 0.72 1122 0.78 1159 0.85 1193 0.91 1226 0.98 1440 1107 0.79 1145 0.86 1181 0.93 1216 1.00 1248 1.07 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK71x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK51x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 120 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 93. Belt drive evaporator fan performance - 4 tons high efficiency - THC048E3,E4 downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1280 - - - - 581 0.17 644 0.21 703 0.26 757 0.30 809 0.35 857 0.40 903 0.45 947 0.51 1440 - - 537 0.17 604 0.21 665 0.26 722 0.30 774 0.35 823 0.40 871 0.45 916 0.51 959 0.56 1600 - - 567 0.21 630 0.26 689 0.31 F742 0.36 793 0.41 842 0.46 887 0.51 932 0.57 974 0.63 1760 - - 597 0.26 658 0.31 713 0.36 765 0.42 814 0.47 860 0.53 905 0.58 947 0.64 1920 561 0.25 627 0.31 687 0.37 F739 0.43 790 0.49 838 0.55 882 0.60 924 0.66 966 0.72 989 0.70 1006 0.79 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 990 0.56 1031 0.62 1069 0.68 1105 0.74 1140 0.80 1440 999 0.62 1040 0.68 1079 0.75 1115 0.81 1152 0.87 1600 1014 0.69 1051 0.75 1089 0.82 1125 0.88 1162 0.95 1760 1028 0.77 F1066 0.83 1104 0.90 1139 0.96 1175 1.04 1920 1044 0.85 1083 0.92 1118 0.99 1155 1.06 1188 1.13 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK74x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK54x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK410/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 121 TRAMS WF Evaporator Fan Performance Table 94. Belt drive evaporator fan performance - 4 tons high efficiency - THC048E3,E4 horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1280 - - 541 0.16 625 0.21 700 0.27 F764 0.33 819 0.40 868 0.46 912 0.52 951 0.58 989 0.64 1440 - - 567 0.19 644 0.25 718 0.32 783 0.38 841 0.45 892 0.52 939 0.59 982 0.66 1022 0.73 1600 - - 596 0.24 668 0.30 1760 555 0.23 625 0.29 694 0.35 1920 593 0.28 657 0.35 723 0.42 736 0.36 801 0.44 861 0.51 757 0.42 820 0.50 879 0.58 783 0.49 840 0.57 897 0.65 915 0.59 963 0.67 1007 0.74 933 0.66 984 0.74 1030 0.83 951 0.74 1001 0.83 1049 0.92 1048 0.82 F1072 0.91 1093 1.01 1-hp Standard Motor & Field Supplied High Static Drive(c) Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1023 0.70 1057 0.76 1090 0.82 1123 0.89 1157 0.95 1440 1057 0.80 11091 0.86 1123 0.93 1155 1.00 1184 1.07 1600 1087 0.90 1123 0.97 1156 1.05 1187 1.12 1217 1.20 1760 1113 1.00 1150 1.08 1184 1.17 1219 1.25 1250 1.34 1920 1135 1.10 1174 1.19 1210 1.29 1244 1.38 1278 1.47 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK74x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK54x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 122 RT-PRCO23-EN qW TRANE Evaporator Fan Performance Table 95. Belt drive evaporator fan performance - 4 tons high efficiency - YHCO48E3,E4*L,M low & medium gas heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1280 - - - - 589 0.18 652 0.23 710 0.27 763 0.32 812 0.37 858 0.42 905 0.47 949 0.53 1440 - - 546 0.18 614 0.22 675 0.27 731 0.32 782 0.37 830 0.42 876 0.48 919 0.53 961 0.59 1600 - - 575 0.22 641 0.27 699 0.32 752 0.37 803 0.43 1760 538 0.21 606 0.27 668 0.32 725 0.38 776 0.44 826 0.50 1920 574 0.27 638 0.32 696 0.38 F752 0.45 802 0.51 850 0.57 851 0.49 895 0.54 938 0.60 872 0.56 916 0.62 958 0.68 895 0.63 938 0.70 978 0.77 978 0.66 997 0.75 1018 0.84 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 993 0.58 1032 0.64 1070 0.70 1107 0.76 1143 0.82 1440 1003 0.65 1043 0.71 1082 0.77 1118 0.84 1154 0.90 1600 1017 0.72 1054 0.78 1092 0.85 1129 0.92 1165 0.98 1760 1036 0.81 1073 0.88 1108 0.94 1142 1.01 1177 1.08 1920 1056 0.91 11092 0.98 1127 1.04 1160 1.11 1193 1.19 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK740/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK54x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 123 TRAMS WF Evaporator Fan Performance Table 96. Belt drive evaporator fan performance - 4 tons high efficiency - YHC048E3,E4*L,M low & medium gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1280 554 0.16 622 0.21 685 0.26 741 0.31 794 0.36 842 0.42 888 0.47 931 0.53 973 0.59 1440 590 0.21 652 0.26 712 0.31 767 0.36 818 0.42 866 0.48 911 0.54 953 0.60 995 0.67 1600 561 0.21 628 0.26 686 0.32 741 0.37 794 0.43 844 0.49 890 0.55 935 0.62 976 0.68 1017 0.75 1760 602 0.27 667 0.33 722 0.38 773 0.44 822 0.50 871 0.57 917 0.63 960 0.70 1001 0.77 1040 0.84 1920 644 0.33 706 0.40 760 0.46 809 0.52 855 0.59 900 0.66 944 0.73 987 0.80 1027 0.87 F1066 0.95(c) Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1012 0.65 1052 0.72 1090 0.78 1127 0.84 1162 0.91 1440 1032 0.73 1070 0.80 1107 0.87 1142 0.94 1175 1.01 1600 1055 0.82 1093 0.89 1128 0.96 1162 1.03 1195 1.11 1760 1078 0.91 1114 0.99 1150 1.06 1183 1.14 1217 1.22 1920 1103 1.02 1139 1.10 1174 1.18 1207 1.26 1239 1.34 1-hp Standard Motor & Field Supplied High Static Drive() Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK74x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK54x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 124 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 97. Belt drive evaporator fan performance - 4 tons high efficiency - YHC048E3,E4*H high gas heat downf low airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1280 - - 528 0.15 600 0.19 661 0.23 717 0.28 771 0.33 821 0.38 870 0.43 915 0.48 959 0.54 1440 - - 556 0.18 626 0.23 687 0.28 740 0.33 790 0.38 839 0.43 886 0.49 930 0.54 974 0.61 1600 - - 586 0.22 651 0.28 712 0.34 766 0.39 814 0.44 860 0.50 904 0.55 947 0.61 990 0.68 1760 554 0.22 619 0.28 680 0.33 738 0.39 792 0.46 841 0.52 884 0.58 926 0.63 967 0.69 1007 0.76 1920 592 0.28 653 0.34 710 0.39 765 0.46 817 0.53 866 0.60 912 0.67 953 0.73 992 0.79 1028 0.85 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1003 0.60 1045 0.66 1083 0.71 1121 0.77 1156 0.83 1440 1013 0.66 1054 0.73 11094 0.79 1132 0.86 1168 0.92 1600 1029 0.74 1069 0.81 1106 0.87 1142 0.94 1177 1.01 1760 1046 0.82 1084 0.89 1121 0.96 1156 1.03 1191 1.11 1920 1066 0.92 1103 0.99 1139 1.06 1174 1.14 1206 1.21 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK74x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK54x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 125 TRAMS WF Evaporator Fan Performance Table 98. Belt drive evaporator fan performance - 4 tons high efficiency - YHC048E3,E4*H high gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 . SO .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drivem 1-hp Standard Motor & Drive(b) 1280 561 0.16 626 0.20 684 0.25 739 0.29 792 0.34 842 0.39 890 0.45 935 0.50 977 0.56 1440 595 0.20 659 0.25 � 715 0.30 1 766 0.35 816 0.40 864 0.45 909 0.51 953 0.57 995 0.63 1600 561 0.20 628 0.25 694 0.31 748 0.36 798 0.41 843 0.47 888 0.52 932 0.58 974 0.64 1015 0.71 1760 603 0.26 665 0.31 727 0.37 782 0.43 830 0.49 875 0.54 917 0.60 958 0.67 998 0.73 1038 0.80 1920 646 0.32 705 0.38 761 0.44 816 0.52 864 0.58 908 0.63 949 0.70 988 0.76 1026 0.83 1063 0.90(0 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1280 1018 0.62 1058 0.68 1095 0.74 1131 0.81 1166 0.87 1440 1036 0.69 1075 0.76 1113 0.82 1148 0.89 1183 0.96 1600 1055 0.77 1093 0.84 1130 0.91 1166 0.98 1201 1.05 1760 1075 0.86 1113 0.93 1149 1.00 1184 1.08 1219 1.15 1920 1100 0.97 1135 1.04 1171 1.11 1204 1.19 1237 1.26 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK74x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK54x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 126 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 99. Belt drive evaporator fan performance - 5 tons high efficiency - THC060E3,E4 downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor &Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1600 570 0.21 631 0.25 691 0.31 745 0.36 794 0.41 842 0.46 887 0.52 930 0.57 972 0.63 1800 � 609 0.27 667 0.32 721 0.37 773 0.43 823 0.49 868 0.55 911 0.61 953 0.67 992 0.73 2000 589 0.29 650 0.35 706 0.40 755 0.46 804 0.52 851 0.58 897 0.65 938 0.71 978 0.77 1017 0.84 2200 636 0.37 692 0.43 745 0.50 793 0.56 838 0.62 882 0.68 925 0.75 967 0.83 1007 0.90 1044 0.97 2400 683 0.47 736 0.54 785 0.61 833 0.68 875 0.74 916 0.81 956 0.88 996 0.95 1036 1.03 1073 1.11 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1013 0.70 1051 0.76 1088 0.82 1124 0.89 1160 0.96 1800 1031 0.79 1070 0.86 1106 0.93 1142 1.00 1176 1.07 2000 1054 0.91 1091 0.98 1126 1.04 1161 1.12 1195 1.19 2200 1080 1.04 1115 1.11 1148 1.18 1183 1.26 1215 1.33 2400 1108 1.19 1142 1.27 1176 1.34 1207 1.42 1238 1.49 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 127 TRAME WF Evaporator Fan Performance Table 100. Belt drive evaporator fan performance - 5 tons high efficiency - THC060E3,E4 horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drivem 1-hp Standard Motor & Drive(b) 1600 -- 622 0.24 688 0.29 753 0.35 F820 0.41 881 0.49 930 0.55 975 0.62 1015 0.68 1052 0.75 1800 598 0.25 668 0.31 728 0.37 785 0.42 843 0.49 903 0.56 960 0.64 1010 0.72 1053 0.80 1092 0.87 2000 648 0.33 714 0.39 771 0.46 824 0.52 875 0.58 927 0.66 982 0.74 1034 0.83 1082 0.91 1126 1.00 2200 699 0.42 762 0.50 816 0.57 866 0.63 914 0.70 960 0.77 1006 0.85 1056 0.94 1106 1.03 1152 1.13 2400 750 0.54 810 0.61 863 0.69 911 0.77 956 0.84 999 0.92 1042 1.00 1084 1.08 1130 1.17 1176 1.27 1-hp Standard Motor & Field Supplied High Static Drive(c) Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1087 0.81 1121 0.88 1152 0.94 1182 1.00 1213 1.07 1800 1129 0.95 1163 1.02 1195 1.09 1226 1.16 1255 1.23 2000 1165 1.08 1201 1.17 1236 1.25 1268 1.33 - - 2200 1196 1.23 1237 1.33 1271 1.42 - - - - 2400 1219 1.37 1261 1.48 - - - - - - 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. S. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 128 RT-PRCO23-EN qW TRANE Evaporator Fan Performance Table 101. Belt drive evaporator fan performance - 5 tons high efficiency - YHC060E3,E4*L,M low & medium gas heat downflow airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1600 583 0.22 648 0.27 705 0.32 755 0.37 804 0.42 852 0.47 897 0.53 941 0.59 982 0.65 1800 - - 623 0.28 683 0.34 740 0.40 790 0.45 835 0.50 879 0.56 922 0.62 964 0.68 1004 0.74 2000 605 0.30 665 0.36 721 0.42 774 0.48 824 0.55 870 0.61 911 0.66 951 0.73 991 0.79 1028 0.86 2200 653 0.39 709 0.45 762 0.51 812 0.58 859 0.65 905 0.72 948 0.79 986 0.86 1022 0.92 1057 0.99 2400 701 0.49 756 0.56 803 0.63 851 0.70 896 0.77 939 0.85 982 0.93 1022 1.00 1057 1.07 1092 1.14 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1024 0.71 1061 0.77 1099 0.83 1136 0.90 1170 0.96 1800 1044 0.81 1081 0.87 1118 0.94 1155 1.01 1188 1.08 2000 1067 0.93 1103 1.00 1139 1.07 1175 1.14 1209 1.22 2200 1094 1.06 1129 1.13 1163 1.21 1197 1.29 1229 1.36 2400 1124 1.21 1157 1.29 1189 1.37 1222 1.45 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 129 TRAMS WF Evaporator Fan Performance Table 102. Belt drive evaporator fan performance - 5 tons high efficiency - YHC060E3,E4*L,M low & medium gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1600 566 0.21 633 0.26 694 0.31 747 0.36 798 0.41 848 0.47 895 0.52 939 0.58 981 0.65 1021 0.71 1800 621 0.28 681 0.33 739 0.39 790 0.45 837 0.51 884 0.57 929 0.63 971 0.69 1013 0.76 1052 0.82 2000 676 0.37 731 0.43 785 0.49 836 0.56 880 0.62 923 0.69 966 0.75 1006 0.82 1046 0.89 1084 0.96 2200 732 0.48 784 0.54 832 0.61 881 0.68 927 0.75 967 0.83 1005 0.90 1044 0.97 1082 1.04 1118 1.12 2400 789 0.61 F838 0.68 882 0.75 927 0.82 972 0.90 1012 0.98 1049 1.06 1085 1.14 1121 1.22 1155 1.30(c) Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1060 0.78 1097�11351169 0.98 1203 1.04 1800 1090 0.89 11261195 1.11 1229 1.19 2000 1121 1.03 1156 1.10 1192 1.18 1224 1.26 1257 1.34 2200 1155 1.19 1189 1.27 1223 1.34 1256 1.42 - - 2400 1190 1.38 1223 1.46 - - - - - - 1-hp Standard Motor & Field Supplied High Static Drive() Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 130 RT-PRCO23-EN A TRANE Evaporator Fan Performance Table 103. Belt drive evaporator fan performance - 5 tons high efficiency - YHC060E3,E4*H high gas heat downf low airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1-hp Standard Motor & Drive(b) 1600 595 0.22 658 0.27 716 0.32 768 0.37 817 0.42 864 0.47 910 0.53 954 0.59 996 0.65 1800 - - 637 0.29 697 0.34 752 0.40 802 0.45 849 0.51 893 0.56 936 0.62 979 0.68 1019 0.75 2000 621 0.31 680 0.36 737 0.42 790 0.49 838 0.55 884 0.61 927 0.67 967 0.73 1007 0.80 1046 0.86 2200 671 0.40 726 0.46 779 0.52 829 0.59 876 0.66 919 0.72 962 0.79 1002 0.86 1039 0.93 1076 1.00 2400 721 0.50 773 0.57 822 0.64 870 0.71 916 0.78 957 0.86 998 0.93 1036 1.00 1074 1.08 1109 1.15 Continued External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1037 0.72 1076 0.78 1114 0.85 1151 0.91 1184 0.98 1800 1058 0.82 1096 0.88 1133 0.95 1169 1.02 1204 1.10 2000 1083 0.93 1120 1.00 1155 1.07 1189 1.15 1224 1.23 2200 1111 1.07 1146 1.14 1181 1.22 1214 1.29 1248 1.37 2400 1144 1.23 1177 1.30 1210 1.38 1241 1.46 1274 1.54 1-hp Standard Motor & Field Supplied High Static Drive(c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. RT-PRCO23-EN 131 TRAMS WF Evaporator Fan Performance Table 104. Belt drive evaporator fan performance - 5 tons standard efficiency - YHC060E3,E4*H high gas heat horizontal airflow External Static Pressure (Inches of Water) .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 cfm rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Field Supplied Low Static Drive(a) 1600 570 0.21 639 0.26 703 0.32 760 0.37 809 0.41 854 0.46 1800 620 0.28 689 0.34 746 0.40 801 0.46 851 0.52 896 0.57 2000 671 0.36 741 0.44 792 0.50 844 0.57 893 0.64 939 0.71 2200 723 0.46 791 0.55 843 0.62 889 0.69 936 0.77 981 0.85 2400 776 0.58 841 0.68 895 0.76 937 0.84 981 0.91 1023 1.00 Continued cfm External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp 1-hp Standard Motor & Drive(b) 1600 1057 0.76 1096 0.83 1133 0.90 1167 0.96 1201 1.03 1800 1086 0.88 1123 0.95 1159 1.02 1192 1.09 1226 1.17 2000 1119 1.02 1153 1.09 1188 1.17 1221 1.24 1253 1.32 2200 1162 1.18 1193 1.25 1223 1.33 1253 1.41 1284 1.49 2400 1206 1.38 1236 1.44 1266 1.52 1294 1.61 1320 1.69 1-hp Standard Motor & Field Supplied High Static Drive(c) 1-hp Standard Motor & Drive(b) 894 0.52 936 0.58 977 0.64 1019 0.70 937 0.62 974 0.68 1011 0.75 1048 0.81 980 0.76 1019 0.82 1054 0.88 1087 0.95 1022 0.92 1061 0.99 1097 1.05 1131 1.11 1064 1.09 1103 1.17 1140 1.25 F1173 1.31 (c) Notes: 1. For Standard Evaporator Fan Speed (rpm), reference Table 110, p. 134. 2. Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data. 3. Data does not include pressure drop due to reheat coil. 4. Refer to Table 115, p. 137 to determine additional static pressure drop due to other options/accessories. 5. 1-hp Fan Motor Heat (MBh) = 2.7672 x Fan bhp+0.4705. 6. Factory supplied motors, in equipment, are definite purpose motors, specifically designed and tested to operate at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product's warranty will not be affected. (a) Field Supplied Fan Sheave AK69x3/4" required. Field Supplied Belt may be necessary. (b) Field Supplied Fan Sheave AK49x3/4" required. Field Supplied Belt may be necessary. (c) Field Supplied Fan Sheave AK41x3/4" required. Field Supplied Belt may be necessary. 132 RT-PRCO23-EN 0 TRANE' Fan Performance Table 105. Standard motor & sheave/fan speed (rpm) Unit Model Fan 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn Tons Number Sheave Open Open Open Open Open Open Closed 3 T/YSC036E3 AK51x3/4" N/A 765 835 905 975 1045 1115 4 T/YSC048E3 AK49x3/4" N/A 804 876 948 1020 1091 1163 5 T/YSC060E3 AK44x3/4" N/A 885 966 1049 1131 1212 1295 6 T/YSC072E AK64x1" N/A 723 779 835 890 946 1002 71/2-81/2 T/YSC092-102E AK59x1" N/A 787 847 908 968 1029 1089 10 T/YSC120E AK59x1" N/A 908 969 1029 1090 1150 1211 3 WSC036E3 AK51x3/4" N/A 761 835 909 982 1057 1125 4 WSC048E3 AK49x3/4" N/A 801 874 946 1019 1091 1164 5 WSC060E3 AK49X3/4" N/A 798 868 939 1010 1081 1152 Note: Factory set at 3 turns open. Table 106. Standard motor & low static drive accessory sheave/fan speed (rpm) Unit Model Fan 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn Tons Number Sheave Open Open Open Open Open Open Closed 3 T/YSC036E3 AK71x3/4" N/A 556 606 657 707 757 808 4 T/YSC048E3 AK69x3/4" N/A N/A 624 675 727 779 832 5 T/YSC060E3 AK61x3/4" N/A N/A 708 765 823 880 938 71/2 TSC092E AK99x1" N/A 462 498 533 569 604 640 71/2 TSC092E AK79x1" N/A 582 627 672 716 761 806 81/2 TSC102E AK99x1" N/A 462 498 533 569 604 640 81/2 TSC102E AK79x1" N/A 582 627 672 716 761 806 10 TSC120E AK94x1" N/A 563 600 638 675 713 750 10 TSC120E AK74x1" N/A 719 767 815 862 910 958 3 WSC036E3 AK71x3/4" N/A 549 600 650 701 751 802 4 WSC048E3 AK69x3/4" N/A 567 619 671 723 775 828 5 WSC060E3 AK69x3/4" N/A 566 617 668 719 770 821 Note: Factory set at 3 turns open. Table 107. Standard motor & high static drive accessory sheave/fan speed (rpm) Unit Model Fan 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn Tons Number Sheave Open Open Open Open Open Open Closed 3 T/YSC036E3 AK41x3/4" N/A 967 1040 1113 1187 1228 N/A 4 T/YSC048E3 AK41x3/4" N/A 957 1033 1110 1187 1263 N/A 5 T/YSC060E3 N/A N/A N/A N/A N/A N/A N/A N/A 6 T/YSC072E3,E4,EW N/A N/A 831 895 959 1022 1086 1150 3 WSC036E3 AK41 x 3/4" N/A 966 1041 1115 1190 1227 N/A 4 WSC048E3 AK41 x 3/4" N/A 958 1034 1110 1186 1261 N/A 5 WSC060E3 AK41 x 3/4" N/A 970 1034 1097 1161 1224 N/A Note: Factory set at 3 turns open RT-PRCO23-EN 133 TRAWE WF Fan Performance Table 108.Oversized motor & drive sheave/fan speed (rpm) Unit Model 6 Turns 5 Turns Tons Number Open Open 4 Turns 3 Turns 2 Turns Open Open Open 1 Turn Open Closed 6 T/Y*C072E N/A 958 1022 1086 1150 1214 1278 71/2 T/Y*C092E N/A 958 1022 1086 1150 1214 1278 81/2 T/Y*C102E N/A 958 1022 1086 1150 1214 1278 10 T/Y*C120E 1050 1135 1200 1275 1350 1425 N/A Notes: Factory set at 3 turns open. * Indicates both standard and high efficiency units and both ReliaTel— and Electromechanical controls. Table 109.Outdoor sound power level - dB (ref. 10 - 12 W) Unit Model Tons Number 63 125 Octave Center Frequency 250 500 1000 2000 4000 8000 Overall dBA 3 T/YSC036E1, E3, E4, EW 79 85 79 79 77 71 67 58 81 4 T/YSC048E1, E3, E4, EW 82 84 83 80 76 72 66 58 82 5 T/YSC060E1, E3, E4, EW 85 82 81 81 77 72 67 61 82 6 T/YSC072E 91 95 90 87 84 79 75 68 89 71/2 T/YSC092E 92 96 92 89 85 80 76 69 91 81/2 T/YSC102E 91 95 90 87 84 79 75 68 89 10 T/YSC120E 94 89 87 85 84 78 75 69 88 3 WSC036E1 79 85 80 79 77 72 67 59 81 3 WSC036E3, E4, EW 77 85 79 78 75 71 66 59 80 4 WSC048E1, E3, E4, EW 81 82 83 81 77 72 66 59 82 5 WSC060E1, E3, E4, EW 81 87 84 85 83 78 73 67 87 Note: Tests follow ARI270-95. Table 110. Standard motor & sheave/fan speed (rpm) Unit Model Fan 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns Tons Number Sheave Open Open Open Open Open 1 Turn Open Closed 15 SEER High Efficiency 3 T/YHC036E AK510/4" N/A 765 835 905 975 1045 1115 4 T/YHC048E AK54x3/4" N/A 729 794 860 926 991 1057 5 T/YHC060E AK49x3/4" N/A 801 871 942 1012 1083 1154 Note: Factory set at 3 turns open. Table 111. Standard motor & low static drive accessory sheave/fan speed (rpm) Unit Model Fan 6 Turns Tons Number Sheave Open 5 Turns Open 4 Turns 3 Turns Open Open 2 Turns Open 1 Turn Open Closed 3 T/YHC036E AK71x3/4" N/A 556 606 657 707 757 808 4 T/YHC048E AK74x3/4" N/A 528 576 625 673 722 770 5 T/YHC060E AK69x3/4" N/A 565 617 669 721 773 825 Note: Factory set at 3 turns open. 134 RT-PRCO23-EN A TRANE Fan Performance Table 112. Standard motor & high static drive accessory sheave/fan speed (rpm) Unit Model Fan 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn Tons Number Sheave Open Open Open Open Open Open Closed 3 T/YHC036E AK41x3/4" N/A N/A 967 1040 1113 1187 N/A 4 T/YHC048E AK41x3/4" N/A N/A 966 1048 1132 1215 N/A 5 T/YHC060E AK41x3/4" N/A N/A 961 1041 1122 1203 N/A Note: Factory set at 3 turns open. Table 113. Outdoor sound power level - dB (ref. 10 - 12 W) Unit Model Octave Center Frequency Overall Tons Number 63 125 250 500 1000 2000 4000 8000 dBA 3 YHC036E1,E3 79 85 79 79 77 71 67 58 81 4 YHC048E1,E3 80 86 84 85 83 79 73 67 87 5 YHC060E1,E3 80 86 84 85 83 79 73 67 87 Note: Tests follow AP1270-95 Table 114. Static pressure drop through accessories (inches water column) - 3-10 tons Economizer with OA/RA Electric Heater Accessory Dampers(a) (kW)(b),(c) 100% 100% 100% 100% Unit Model Standard 2" MERV 7 2" MERV 13 OA RA OA RA 5-6 9-15 17-36 54 Tons Number cfm Filters(d) Filter Filter Downflow Horizontal 3 T/YSC036E1 960 0.01 0.03 0.04 0.04 0.01 0.04 0.01 0.01 0.01 0.01 - 3 T/YSC036E1 1200 0.02 0.04 0.05 0.06 0.01 0.06 0.01 0.02 0.02 0.02 - 3 T/YSC036E1 1440 0.03 0.05 0.06 0.08 0.02 0.08 0.01 0.02 0.03 0.03 - 3 T/YSC036E3 960 0.01 0.03 0.04 0.04 0.01 0.04 0.01 0.01 0.01 0.01 - 3 T/YSC036E3 1200 0.02 0.04 0.05 0.06 0.01 0.06 0.01 0.02 0.02 0.02 - 3 T/YSC036E3 1440 0.03 0.05 0.06 0.08 0.02 0.08 0.01 0.02 0.03 0.03 - 4 T/YSC048E1 1280 0.03 0.05 0.06 0.09 0.02 0.09 0.01 0.02 0.03 0.03 - 4 T/YSC048E1 1600 0.04 0.07 0.07 0.13 0.04 0.13 0.02 0.04 0.05 0.05 - 4 T/YSC048E1 1920 0.06 0.10 0.08 0.17 0.06 0.17 0.02 0.05 0.06 0.08 - 4 T/YSC048E3 1280 0.03 0.05 0.06 0.09 0.02 0.09 0.01 0.02 0.03 0.03 - 4 T/YSC048E3 1600 0.04 0.07 0.07 0.13 0.04 0.13 0.02 0.04 0.05 0.05 - 4 T/YSC048E3 1920 0.06 0.10 0.08 0.17 0.06 0.17 0.02 0.05 0.06 0.08 - 5 T/YSC060E1 1600 0.04 0.07 0.07 0.13 0.04 0.13 0.02 0.04 0.05 0.05 - 5 T/YSC060E1 2000 0.06 0.10 0.09 0.18 0.07 0.18 0.02 0.06 0.07 0.08 - 5 T/YSC060E1 2400 0.08 0.13 0.10 0.25 0.11 0.25 0.03 0.08 0.10 0.12 - 5 T/YSC060E3 1600 0.04 0.07 0.07 0.13 0.04 0.13 0.02 0.04 0.05 0.05 - 5 T/YSC060E3 2000 0.06 0.10 0.09 0.18 0.07 0.18 0.02 0.06 0.07 0.08 - 5 T/YSC060E3 2400 0.08 0.13 0.10 0.25 0.11 0.25 0.03 0.08 0.10 0.12 - 6 T/YSC072E 1920 0.04 0.07 0.10 0.10 0.01 0.06 0.02 0.02 0.011 0.021 - 6 T/YSC072E 2400 0.06 0.09 0.13 0.11 0.02 0.08 0.02 0.02 0.020 0.034 - 6 T/YSC072E 2880 0.09 0.12 0.15 0.13 0.04 0.10 0.04 0.04 0.033 0.052 - continued on next page RT-PRCO23-EN 135 M TRAWE WF Fan Performance Table 114. Static pressure drop through accessories (inches water column) - 3-10 tons (continued) Economizer with OA/RA Electric Heater Accessory Dampers(a) (kW)(b),(c) 100% 100% 100% 100% Unit Model Standard 2" MERV 7 2" MERV 13 OA RA OA RA 5-6 9-15 17-36 54 Tons Number cfm Filters(d) Filter Filter Downflow Horizontal 71/2 T/YSC092E 2400 0.04 0.06 0.12 0.11 0.02 0.08 0.02 0.02 0.016 0.021 - 71/2 T/YSC092E 3000 0.06 0.09 0.13 0.14 0.05 0.12 0.05 0.05 0.025 0.032 - 71/2 T/YSC092E 3600 0.09 0.13 0.15 0.21 0.07 0.25 0.08 0.08 0.036 0.046 - 81/2 TIYSC102E 2720 0.05 0.08 0.13 0.12 0.03 0.09 0.04 0.04 0.020 0.026 - 81/2 TIYSC102E 3400 0.08 0.11 0.14 0.19 0.06 0.18 0.06 0.06 0.032 0.041 - 81/2 T/YSC102E 4080 0.12 0.16 0.16 0.30 0.07 0.31 0.09 0.09 0.047 0.059 - 10 T/YSC120E 3200 0.07 0.10 0.14 0.17 0.05 0.14 0.05 0.05 0.028 0.036 0.042 10 T/YSC120E 4000 0.11 0.15 0.16 0.26 0.07 0.30 0.08 0.08 0.045 0.056 0.070 10 T/YSC120E 4800 0.16 0.20 0.18 0.34 0.09 0.35 0.10 0.10 0.065 0.081 0.106 3 WSC036E1 960 0.02 0.03 0.03 0.05 0.01 0.05 0.01 0.01 0.02 0.02 - 3 WSC036E1 1200 0.03 0.05 0.04 0.07 0.02 0.07 0.01 0.02 0.03 0.03 - 3 WSC036E1 1440 0.03 0.06 0.04 0.10 0.03 0.10 0.01 0.03 0.04 0.04 - 3 WSC036E3 960 0.02 0.03 0.03 0.05 0.01 0.05 0.01 0.01 0.02 0.02 - 3 WSC036E3 1200 0.03 0.05 0.04 0.07 0.02 0.07 0.01 0.02 0.03 0.03 - 3 WSC036E3 1440 0.03 0.06 0.04 0.10 0.03 0.10 0.01 0.03 0.04 0.04 - 4 WSC048E1 1280 0.03 0.05 0.06 0.09 0.02 0.09 0.01 0.02 0.03 0.03 - 4 WSC048E1 1600 0.04 0.07 0.07 0.13 0.04 0.13 0.02 0.04 0.05 0.05 - 4 WSC048E1 1920 0.06 0.10 0.08 0.17 0.06 0.17 0.02 0.05 0.06 0.08 - 4 WSC048E3 1280 0.03 0.05 0.06 0.09 0.02 0.09 0.01 0.02 0.03 0.03 - 4 WSC048E3 1600 0.04 0.07 0.07 0.13 0.04 0.13 0.02 0.04 0.05 0.05 - 4 WSC048E3 1920 0.06 0.10 0.08 0.17 0.06 0.17 0.02 0.05 0.06 0.08 - 5 WSC060E1 1600 0.03 0.06 0.05 0.09 0.01 0.05 0.01 0.01 0.01 0.02 - 5 WSC060E1 2000 0.05 0.08 0.07 0.11 0.01 0.07 0.02 0.02 0.01 0.03 - 5 WSC060E1 2400 0.07 0.10 0.10 0.12 0.03 0.09 0.03 0.03 0.02 0.04 - 5 WSC060E3 1600 0.03 0.06 0.05 0.09 0.01 0.05 0.01 0.01 0.01 0.02 - 5 WSC060E3 2000 0.05 0.08 0.07 0.11 0.01 0.07 0.02 0.02 0.01 0.03 - 5 WSC060E3 2400 0.07 0.10 0.10 0.12 0.03 0.09 0.03 0.03 0.02 0.04 - (a) OA = Outside Air and RA = Return Air. (b) Nominal kW ratings at 240, 480, 600 volts. (c) Electric heaters restricted on applications below 320 cfm/Ton. (d)Tested with standard filters. Difference in pressure drop should be considered when utilizing optional 2" MERV 7 and MERV 13 filters 136 RT-PRCO23-EN A TRANE Fan Performance Table 115. Static pressure drop through accessories (inches water column) - 3-5 tons Economizer with OA/RA Electric Heater Accessory Dampers(a) (kW)(b) Ton 100% 100% 100% 100% s Unit Model cfm Standard 2" MERV 7 2" MERV 13 OA RA OA RA 5-6 9-15 17-36 Number Filters(c) Filter Filter Downflow Horizontal 3 T/YHC036E1 960 0.013 0.027 0.04 0.041 0.007 0.041 0.006 0.010 0.012 0.014 3 T/YHC036E1 1200 0.020 0.037 0.05 0.059 0.013 0.059 0.008 0.015 0.019 0.022 3 T/YHC036E1 1440 0.027 0.048 0.06 0.080 0.021 0.080 0.010 0.022 0.027 0.032 3 T/YHC036E3,4 960 0.013 0.027 0.04 0.041 0.007 0.041 0.006 0.010 0.012 0.014 3 T/YHC036E3,4 1200 0.020 0.037 0.05 0.059 0.013 0.059 0.008 0.015 0.019 0.022 3 T/YHC036E3,4 1440 0.027 0.048 0.06 0.080 0.021 0.080 0.010 0.022 0.027 0.032 4 T/YHC048E1 1280 0.015 0.042 0.03 4 T/YHC048E1 1600 0.031 0.059 0.05 4 T/YHC048E1 1920 0.046 0.076 0.07 4 T/YHC048E3,4 1280 0.015 0.042 0.03 4 T/YHC048E3,4 1600 0.031 0.059 0.05 4 T/YHC048E3,4 1920 0.046 0.076 0.07 5 T/YHC060E1 1600 0.031 0.059 0.08 5 T/YHC060E1 2000 0.049 0.079 0.11 5 T/YHC060E1 2400 0.070 0.101 0.13 5 T/YHC060E3,4 1600 0.031 0.059 0.08 5 T/YHC060E3,4 2000 0.049 0.079 0.11 5 T/YHC060E3,4 2400 0.070 0.101 0.13 0.081 0.000 0.038 0.009 0.009 0.001 0.006 0.092 0.006 0.052 0.015 0.015 0.008 0.016 0.102 0.014 0.066 0.020 0.020 0.014 0.025 0.081 0.000 0.038 0.009 0.009 0.001 0.006 0.092 0.006 0.052 0.015 0.015 0.008 0.016 0.102 0.014 0.066 0.020 0.020 0.014 0.025 0.091 0.007 0.052 0.015 0.015 0.008 0.016 0.105 0.014 0.069 0.021 0.021 0.015 0.026 0.118 0.026 0.086 0.029 0.029 0.024 0.040 0.091 0.007 0.052 0.015 0.015 0.008 0.016 0.105 0.014 0.069 0.021 0.021 0.015 0.026 0.118 0.026 0.086 0.029 0.029 0.024 0.040 (a) OA = Outside Air and RA = Return Air. (b) Nominal kW ratings at 240, 480, 600V. Heaters only available on T_C units. (c) Tested with standard filters. Difference in pressure drop should be considered when utilizing optional 2" MERV 7 and MERV 13 filters. Unit applications below 320 cfm/ton are not applicable with Gas Heat or Electric Heaters. Table 116. Gas fired heating capacities - standard efficiency Unit Model Heating Heating Air Temp. Tons Number Input MBh(a) Output MBh Rise, F 3 YSC036El*(L,X) 60 48 25-55 3 YSC036E1*(M,Y) 80 65 35-65 3 YSC036E1*(H,Z) 120 96 55-85 3 YSC036E(3,4,W)*(L,X) 60 48 25-55 3 YSC036E(3,4,W)*(M,Y) 80 64 35-65 3 YSC036E(3,4,W)*(H,Z) 120 96 55-85 4 YSC048E1*(L,X) 60 49 15-45 4 YSC048El*(M,Y) 80 65 20-50 4 YSC048El*(H,Z) 120 96 40-70 4 YSC048E(3,4,W)*(L,X) 60 48 15-45 4 YSC048E(3,4,W)*(M,Y) 80 64 20-50 4 YSC048E(3,4,W)*(H,Z) 120 96 40-70 5 YSC060E1*(L,X) 60 48 10-40 5 YSC060E1*(M,Y) 80 65 15-45 continued on next page RT-PRCO23-EN 137 M TRAWE WF Fan Performance Table 116. Gas fired heating capacities - standard efficiency (continued) Unit Model Heating Heating Air Temp. Tons Number Input MBh(a) Output MBh Rise, F 5 YSC060E1*(H,Z) 130 104 35-65 5 YSC060E(3,4,W)*(L,X) 60 48 10-40 5 YSC060E(3,4,W)*(M,Y) 80 64 15-45 5 YSC060E(3,4,W)*(H,Z) 130 104 35-65 6 YSC072E(3,4,W)*(L,X) 80.0 64.8 15-45 6 YSC072E(3,4,W)*(M,Y) 120.0 97.2 20-50 6 YSC072E(3,4,W)*(H,Z) 150.0/105 121.5/85 25-55 71/2 YSC092E(3,4,W)*(L,X) 120.0 97.2 20-50 71/2 YSC092E(3,4,W)*(M,Y) 150.0/105 121.5/85 25-55 71/2 YSC092E(3,4,W)*(H,Z) 200.0/140 160.0/112 35-65 81/2 YSC102E(3,4,W)*(L,X) 120.0 97.2 15-45 81/2 YSC102E(3,4,W)*(M,Y) 150.0/105 121.5/85 20-50 81/2 YSC102E(3,4,W)*(H,Z) 200.0/140 160.0/112 35-65 10 YSC120E(3,4,W)*(L,X) 150.0/105 121.5/85 20-50 10 YSC120E(3,4,W)*(M,Y) 200.0/140 162.0/113 25-55 10 YSC120E(3,4,W)*(H,Z) 250.0/175 202.5/141.8 35-65 Note: Ratings shown are for elevations up to 2,000 ft. For higher elevations, reduce ratings at a rate of 4% per 1,000 ft. elevation. (a) For two stage heaters (input or output), Second stage is total heating capacity. Second Stage/First Stage. Table 117. Gas fired heating capacities - high efficiency Unit Model Heating Heating Air Temp. Tons Number Input MBh Output MBh Rise, F 3 YHC036E1*(L,X) 60 48 25 - 55 3 YHC036El*(M,Y) 80 65 35 - 65 3 YHC036EI*(H,Z) 120 96 55-85 3 YHC036E(3,4)*(L,X) 60 48 25 - 55 3 YHC036E(3,4)*(M,Y) 80 64 35- 65 3 YHC036E(3,4)*(H,Z) 120 96 55 - 85 4 YHC048El*(L,X) 60 49 10 - 40 4 YHC048El*(M,Y) 80 64 20 - 50 4 YHC048EI*(H,Z) 120 96 40- 70 4 YHC048E(3,4)*(L,X) 60 48 10 - 40 4 YHC048E(3,4)*(M,Y) 80 64 20- 50 4 YHC048E(3,4)*(H,Z) 120 96 40 - 70 5 YHC060E1*(L,X) 60 49 10 - 40 5 YHC060E1*(M,Y) 80 64 15 - 45 5 YHC060E1*(H,Z) 130 104 35-65 5 YHC060E(3,4)*(L,X) 60 48 10 - 40 5 YHC060E(3,4)*(M,Y) 80 64 15-45 5 YHC060E(3,4)*(H,Z) 130 104 35-65 Note: Ratings shown are for elevations up to 2,000 ft. For higher elevations, reduce ratings at a rate of 4% per 1,000 ft. elevation. 138 RT-PRCO23-EN A TRANE Fan Performance Table 118. Auxiliary electric heat capacity Total(a) Stagel Stage 2 Unit Model kW MBh No. of kW MBh kW MBh Tons Number Input(b) Output Stages Input Output Input Output 3 5.00 17.07 1 5.00 17.07 - - T*C036E1 3 10.00 34.14 2 5.00 17.07 5.00 17.07 WSC036E1 3 13.80 47.11 2 5.00 17.07 8.80 30.04 3 6.00 20.48 1 6.00 20.48 - - T*C036E3, E4, EW(c) 3 12.00 40.97 2 6.00 20.48 6.00 20.48 WSC036E3, E4, EW 3 17.40 59.40 2 8.70 29.70 8.70 29.70 4 5.00 17.07 1 5.00 17.07 - - 4 T*C048E1 10.00 34.14 2 5.00 17.07 5.00 17.07 4 WSC048E1 13.80 47.11 2 5.00 17.07 8.80 30.04 4 17.60 60.09 2 8.80 30.04 8.80 30.04 4 6.00 20.48 1 6.00 20.48 - - T*C048E3, E4, EW O 4 WSC048E3, E4, EW 12.00 40.97 2 6.00 20.48 6.00 20.48 4 17.40 59.40 2 8.70 29.70 8.70 29.70 5 5.00 17.07 1 5.00 17.07 - - 5 T*C060E1 10.00 34.14 2 5.00 17.07 5.00 17.07 5 WSC060E1 13.80 47.11 2 5.00 17.07 8.80 30.04 5 17.60 60.09 2 8.80 30.04 8.80 30.04 5 6.00 20.48 1 6.00 20.48 - - 5 T*C060E3,E4,EW(c) 12.00 40.97 2 6.00 20.48 6.00 20.48 5 WSC060E3, E4, EW 17.40 59.40 2 8.70 29.70 8.70 29.70 5 23.00 78.52 2 8.70 29.70 14.30 48.82 6 TSC072E3,4,W 9.00 30.73 1 9.00 30.73 - - 6 TSC072E3,4,W 18.00 61.45 1 18.00 61.45 - - 6 TSC072E3,4,W 27.00 92.18 2 18.00 61.45 9.00 30.73 6 TSC072E3,4,W 36.00 122.90 2 18.00 61.45 18.00 61.45 71/2 TSC092E3,4,W 9.00 30.73 1 9.00 30.73 - - 71/2 TSC092E3,4,W 18.00 61.45 1 18.00 61.45 - - 71/2 TSC092E3,4,W 27.00 92.18 2 18.00 61.45 9.00 30.73 71/2 TSC092E3,4,W 36.00 122.90 2 18.00 61.45 18.00 61.45 81/2 TSC102E3,4,W 9.00 30.73 1 9.00 30.73 - - 81/2 TSC102E3,4,W 18.00 61.45 1 18.00 61.45 - - 81/2 TSC102E3,4,W 27.00 92.18 2 18.00 61.45 9.00 30.73 81/2 TSC102E3,4,W 36.00 122.90 2 18.00 61.45 18.00 61.45 10 TSC120E3,4,W 27.00 92.18 2 18.00 61.45 9.00 30.73 10 TSC120E3,4,W 36.00 122.90 2 18.00 61.45 18.00 61.45 10 TSC120E3,4,W 54.00 184.36 2 36.00 122.90 18.00 61.45 (a) Heaters are rated at 240V,380V,480V and 600V. For other than rated voltage, CAP= (voltage/rated voltage)2 x rated cap (b) All input/output does not include indoor fan power or heat. (c) 600V is not available on high efficiency units. RT-PRCO23-EN 139 M TRAWE WF Fan Performance Table 119. Electric heater voltage correction factors (applicable to auxiliary heat capacity) Nominal Distribution Capacity Voltage Voltage Multiplier 240 208 0.751 240 230 0.918 240 240 1.000 480 440 0.840 480 460 0.918 480 480 1.000 600 540 0.810 600 575 0.918 600 600 1.000 Table 120. Air temperature rise across electric heaters (IF) 3 Tons(a) 1200 cfm 4 Tons 1600 cfm 5 Tons(b) 2000 cfm Single Phase Three Phase Single Phase Three Phase Single Phase Three Phase T*C036E1 T*C036E3,E4,EW(c) T*C048E1 T*C048E3, E4, EW(c) T*C060E1 T*C06OE3, E4, EW(c) kW Stages WSC036E1 WSC036E3,E4,EW WSC048E1 WSC048E3, E4, EW WSC060E1 WSC060E3, E4, EW 5.00 1 13.8 - 10.5 - 8.5 - 6.00 1 - 18.5 - 10.5 - 11.4 10.00 2 26.8 - 20.3 - 16.3 - 12.00 2 - 36.2 - 22.3 - 21.5 13.80 2 36.9 - 27.8 - 22.3 - 17.40 2 - 48.2 - 33.0 - 30.0 17.60 2 - - 35.5 - 28.3 - 23.0 2 - - - - - 38.8 Notes: 1. For minimum design airflow, see airflow performance table for each unit. 2. To calculate temp rise at different airflow, use the following formula: Temp. rise across Electric Heater = kWx3414/1.08xCFM. (a)The minimum allowable airflow for a 3 ton with a 17.4 kW heater is 1080 cfm. (b)The minimum allowable airflow for a 5 ton unit with a 23.0 kW heater is 1900 cfm. (c) 600V is not available on high efficiency units. 140 RT-PRCO23-EN A TRANE Fan Performance Table 121. 6-10 tons air temperature rise across electric heaters (IF) 6 Tons 71/2 Tons 81/2 Tons 10 Tons 2000 cfm 3000 cfm 3400 cfm(a) 4000 cfm kW Stages TSC072A3, A4, AW TSC092E3,4,W TSC102E3,4,W TSC120E3,4,W 11.30 1 — — — — 16.90 2 — — — — 18.00 1 28.5 19.0 16.7 14.2 22.60 2 — — — — 27.00 2 42.7 28.5 25.1 21.3 33.80 2 — — — — 36.00 2 56.9 37.9 33.5 28.5 54.00 2 — — — 42.7 Notes: 1. For minimum design airflow, see airflow performance table for each unit. 2. To calculate temp rise at different airflow, use the following formula: Temp. rise across Electric Heater = kWx3414/1.08xCFM. (a) Minimum allowable airflow with a 17.4 or 17.6 kW heater is 1440 cfm RT-PRCO23-EN 141 0 T/L411/E Heating Performance Data Table 122. 3 tons single phase heating capacities (net) WSC036E1 at 1200 cfm Outdoor Temp. Integrated Heating Capacity (Btuh/1000) at Indicated Indoor Dry Bulb Temp(a) Total Power in Kilowatts at at Indicated Indoor Dry Bulb Temp F. 60 70 75 80 60 70 75 80 -8 12.3 11.4 11.0 10.5 2.54 2.82 2.96 3.11 -3 14.3 13.5 13.0 12.5 2.58 2.85 3.00 3.17 2 16.5 15.7 15.2 14.8 2.61 2.89 3.05 3.21 7 17.6 16.6 16.0 15.4 2.62 2.90 3.05 3.21 12 20.0 18.9 18.2 17.7 2.67 2.96 3.10 3.26 17 22.4 21.2 20.6 20.0 2.71 2.99 3.14 3.30 22 25.0 23.7 23.1 22.5 2.75 3.03 3.19 3.36 27 27.7 26.4 25.6 25.0 2.80 3.10 3.26 3.43 32 30.3 28.8 28.2 27.4 2.84 3.13 3.30 3.47 37 33.1 31.6 30.8 30.1 2.89 3.20 3.37 3.54 42 35.8 34.2 33.4 32.6 2.94 3.24 3.42 3.60 47 38.8 37.0 36.2 35.4 3.00 3.31 3.49 3.67 52 41.5 39.7 38.8 37.9 3.05 3.37 3.54 3.73 57 44.6 42.6 41.7 40.7 3.12 3.44 3.62 3.81 62 47.4 45.3 44.3 43.3 3.17 3.51 3.69 3.88 67 50.5 48.3 47.4 46.2 3.23 3.59 3.78 3.96 72 53.4 51.0 49.9 48.7 3.30 3.65 3.84 4.04 Notes: 1. For other airflow conditions, see heating capacity correction factor Table 119, p. 140. 2. Net heating capacity and power input includes indoor fan heat at API esp. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. (a) Integrated heating capacities and powers include the effects of defrost in the frost region. All heating capacities and power (kw) are at 70% OD relative humidity and demand defrost cycle. 142 RT-PRCO23-EN A TRANE Heating Performance Data Table 123. 3 tons three phase heating capacities (net) WSC036E3,E4,EW at 1200 cfm Outdoor Integrated Heating Capacity (Btuh/1000) Total Power in Kilowatts at Temp. at Indicated Indoor Dry Bulb Temp(a) at Indicated Indoor Dry Bulb Temp F. 60 70 75 s0 60 70 75 s0 -8 11.7 11.0 10.5 10.2 2.41 2.68 2.81 2.97 -3 13.8 13.0 12.6 12.1 2.45 2.72 2.87 3.02 2 15.9 15.0 14.7 14.3 2.48 2.75 2.92 3.07 7 16.9 15.8 15.3 14.7 2.48 2.76 2.91 3.05 12 19.5 18.3 17.8 17.1 2.53 2.81 2.94 3.12 17 21.8 20.7 20.1 19.5 2.57 2.85 3.02 3.17 22 24.4 23.1 22.6 21.9 2.62 2.90 3.06 3.22 27 27.2 26.0 25.3 24.7 2.66 2.96 3.11 3.29 32 29.9 28.5 27.8 27.1 2.71 3.01 3.18 3.35 37 32.9 31.4 30.7 30.0 2.77 3.08 3.25 3.42 42 35.5 34.0 33.2 32.5 2.82 3.14 3.31 3.49 47 38.7 37.0 36.2 35.5 2.90 3.21 3.38 3.58 52 41.4 39.7 38.8 38.1 2.95 3.27 3.45 3.65 57 44.7 42.9 41.9 41.1 3.02 3.35 3.53 3.73 62 47.5 45.6 44.6 43.8 3.09 3.42 3.61 3.82 67 50.7 48.7 47.8 46.8 3.16 3.51 3.70 3.91 72 53.5 51.5 50.5 49.5 3.22 3.59 3.79 3.99 Notes: 1. For other airflow conditions, see heating capacity correction factor Table 119, p. 140. 2. Net heating capacity and power input includes indoor fan heat at ARI esp. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. (a) Integrated heating capacities and powers include the effects of defrost in the frost region. All heating capacities and power (kw) are at 70% OD relative humidity and demand defrost cycle. RT-PRCO23-EN 143 TRAMS WF Heating Performance Data Table 124. 4 tons single phase heating capacities (net) WSC048E1 at 1200 cfm Outdoor Temp. Integrated Heating Capacity (Btuh/1000) at Indicated Indoor Dry Bulb Temp(a) Total Power in Kilowatts at at Indicated Indoor Dry Bulb Temp F. 60 70 75 80 60 70 75 80 -8 15.2 14.0 13.4 12.8 3.23 3.60 3.81 4.02 -3 17.6 16.5 15.8 15.2 3.24 3.61 3.81 4.03 2 20.3 19.0 18.5 17.8 3.28 3.62 3.83 4.07 7 20.8 19.2 18.3 17.6 3.24 3.59 3.77 3.97 12 23.9 22.2 21.4 20.6 3.27 3.61 3.80 4.01 17 26.6 25.0 24.2 23.4 3.28 3.63 3.82 4.03 22 29.8 28.2 27.3 26.4 3.33 3.68 3.88 4.08 27 33.2 31.5 30.6 29.8 3.37 3.72 3.91 4.13 32 36.2 34.5 33.5 32.6 3.41 3.77 3.95 4.17 37 39.8 37.9 36.9 36.0 3.46 3.81 4.01 4.22 42 42.9 40.9 39.9 38.9 3.50 3.86 4.06 4.27 47 46.6 44.4 43.3 42.3 3.56 3.91 4.11 4.34 52 49.9 47.6 46.4 45.5 3.61 3.97 4.17 4.39 57 53.8 51.2 50.2 49.1 3.67 4.02 4.24 4.46 62 57.3 54.6 53.4 52.2 3.72 4.09 4.30 4.52 67 61.4 58.5 57.1 55.8 3.79 4.16 4.37 4.59 72 64.9 61.9 60.4 59.0 3.85 4.22 4.44 4.67 Notes: 1. For other airflow conditions, see heating capacity correction factor Table 119, p. 140. 2. Net heating capacity and power input includes indoor fan heat at ARI esp. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. (a) Integrated heating capacities and powers include the effects of defrost in the frost region. All heating capacities and power (kw) are at 70% OD relative humidity and demand defrost cycle. 144 RT-PRCO23-EN A TRANE Heating Performance Data Table 125. 4 tons three phase heating capacities (net) WSC048E3,E4,EW at 1200 cfm Outdoor Integrated Heating Capacity (Btuh/1000) Total Power in Kilowatts at Temp. at Indicated Indoor Dry Bulb Temp(a) at Indicated Indoor Dry Bulb Temp F. 60 70 75 80 60 70 75 s0 -8 13.9 12.3 11.4 10.4 3.02 3.33 3.51 3.69 -3 16.7 15.0 14.1 13.2 3.06 3.38 3.55 3.74 2 19.5 17.8 17.1 16.1 3.11 3.44 3.61 3.81 7 20.7 19.0 17.9 16.9 3.11 3.44 3.61 3.80 12 23.8 22.0 21.1 20.0 3.16 3.49 3.67 3.85 17 26.6 24.9 23.9 22.9 3.20 3.53 3.71 3.90 22 29.9 28.1 27.1 26.1 3.24 3.59 3.77 3.96 27 33.3 31.4 30.4 29.3 3.29 3.65 3.82 4.02 32 36.2 34.3 33.3 32.3 3.33 3.69 3.88 4.07 37 39.8 37.8 36.8 35.8 3.39 3.74 3.94 4.15 42 42.9 40.8 39.8 38.7 3.44 3.79 3.99 4.20 47 46.6 44.4 43.3 42.1 3.50 3.86 4.05 4.26 52 50.0 47.6 46.5 45.3 3.55 3.92 4.12 4.33 57 53.9 51.3 50.3 49.0 3.62 3.98 4.19 4.41 62 57.5 54.7 53.4 52.2 3.69 4.05 4.25 4.48 67 61.5 58.7 57.4 56.0 3.75 4.13 4.34 4.56 72 65.0 62.3 60.8 59.3 3.82 4.21 4.42 4.64 Notes: 1. For other airflow conditions, see heating capacity correction factor Table 119, p. 140. 2. Net heating capacity and power input includes indoor fan heat at ARI esp. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. (a) Integrated heating capacities and powers include the effects of defrost in the frost region. All heating capacities and power (kw) are at 70% OD relative humidity and demand defrost cycle. RT-PRCO23-EN 145 TRAMS WF Heating Performance Data Table 126. 5 tons single phase heating capacities (net) WSC060E1 at 1200 cfm Outdoor Temp. Integrated Heating Capacity (Btuh/1000) at Indicated Indoor Dry Bulb Temp(a) Total Power in Kilowatts at at Indicated Indoor Dry Bulb Temp F. 60 70 75 s0 60 70 75 s0 -8 18.6 17.1 16.4 15.7 3.73 4.16 4.37 4.60 -3 22.2 20.9 20.1 19.4 3.82 4.26 4.49 4.71 2 26.0 24.6 23.8 23.0 3.88 4.31 4.55 4.79 7 28.4 26.7 25.7 24.9 3.92 4.36 4.58 4.80 12 32.3 30.2 29.5 28.6 3.97 4.45 4.66 4.91 17 36.2 34.5 33.6 32.7 4.03 4.46 4.69 4.97 22 40.1 38.3 37.4 36.4 4.08 4.52 4.75 5.01 27 44.1 42.2 41.3 40.4 4.15 4.61 4.84 5.08 32 48.2 46.2 45.2 44.2 4.21 4.66 4.90 5.15 37 52.4 50.3 49.2 48.2 4.27 4.72 4.97 5.24 42 56.5 54.3 53.2 52.1 4.33 4.79 5.04 5.31 47 60.7 58.5 57.4 56.2 4.41 4.86 5.12 5.39 52 64.9 62.7 61.4 60.1 4.48 4.94 5.20 5.47 57 69.7 67.0 65.6 64.3 4.55 5.03 5.28 5.57 62 74.1 71.2 69.8 68.4 4.62 5.11 5.38 5.66 67 79.0 75.6 74.1 72.6 4.72 5.19 5.47 5.76 72 83.3 79.9 78.2 76.6 4.80 5.29 5.58 5.88 Notes: 1. For other airflow conditions, see heating capacity correction factor Table 119, p. 140. 2. Net heating capacity and power input includes indoor fan heat at ARI esp. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. (a) Integrated heating capacities and powers include the effects of defrost in the frost region. All heating capacities and power (kw) are at 70% OD relative humidity and demand defrost cycle. 146 RT-PRCO23-EN A TRANE Heating Performance Data Table 127. 5 tons three phase heating capacities (net) WSC060E3,E4,EW at 1600 cfm Outdoor Integrated Heating Capacity (Btuh/1000) Total Power in Kilowatts at Temp. at Indicated Indoor Dry Bulb Temp(a) at Indicated Indoor Dry Bulb Temp F. 60 70 75 s0 60 70 75 s0 -8 20.4 19.4 18.8 18.3 3.68 4.13 4.37 4.64 -3 23.7 22.6 22.0 21.5 3.76 4.21 4.45 4.73 2 27.1 26.0 25.4 24.8 3.84 4.30 4.53 4.81 7 28.6 27.2 26.4 25.7 3.85 4.29 4.54 4.80 12 32.4 30.8 30.1 29.3 3.92 4.37 4.63 4.89 17 36.0 34.4 33.6 32.8 3.98 4.44 4.69 4.96 22 39.9 38.2 37.4 36.6 4.06 4.52 4.77 5.05 27 44.0 42.3 41.3 40.4 4.13 4.61 4.85 5.13 32 47.9 46.1 45.1 44.2 4.20 4.68 4.94 5.21 37 52.2 50.2 49.3 48.3 4.28 4.76 5.03 5.31 42 56.3 54.2 53.2 52.2 4.36 4.84 5.12 5.41 47 60.8 58.5 57.4 56.4 4.45 4.94 5.21 5.50 52 65.0 62.6 61.5 60.3 4.54 5.03 5.30 5.60 57 69.7 67.1 65.9 64.7 4.64 5.13 5.40 5.70 62 74.0 71.3 70.0 68.8 4.74 5.24 5.51 5.81 67 78.8 75.9 74.6 73.2 4.85 5.36 5.63 5.93 72 83.1 80.2 78.7 77.2 4.95 5.48 5.75 6.04 Notes: 1. For other airflow conditions, see heating capacity correction factor Table 119, p. 140. 2. Net heating capacity and power input includes indoor fan heat at ARI esp. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. (a) Integrated heating capacities and powers include the effects of defrost in the frost region. All heating capacities and power (kw) are at 70% OD relative humidity and demand defrost cycle. RT-PRCO23-EN 147 0 T/L411/E Controls ReliaTell" Controlled Units Zone Sensors are the building occupant's comfort control devices. The following zone sensor options are available for Precedent units with ReliaTel control: Manual Changeover Heat, Cool or Off System Switch. Fan Auto or Off Switch. One temperature setpoint lever. Manual/Automatic Changeover Auto, Heat, Cool or Off System Switch. Fan Auto or Off Switch Two temperature setpoint levers. Manual/Automatic Remote Sensor Changeover Auto, Heat, Cool or Off System Sensor(s) available Switch. Fan Auto or Off Switch. Two for all zone sensors to temperature setpoint levers. provide remote sensing capabilities. Manual/Automatic Changeover Auto, Heat, Cool or Off System Switch. Fan Auto or Off Switch. Two temperature setpoint levers. Status Indication LED lights, System On, Heat, Cool, or Service. Integrated ComfortTM System Sensor(s) available with optional temperature adjustment and override buttons to provide central control through a Trane Integrated ComfortT"" system. 148 RT-PRCO23-EN 0 laws" Programmable Night Setback CM Auto Auto or manual changeover with seven-day programming. Keyboard selection of Heat, Cool, Fan, Auto, or On. All programmable sensors have System On, Heat, Cool, Service LED/indicators as standard. Night Setback Sensors have one (1) Occupied, one (1) Un-occupied, and one (1) Override program per day. Digital Display Programmable Thermostat with Built -In Relative Humidity Sensing (3H/2C) C I_I I_I_I ;23C L i Three Heat/Two Cool digital display thermostat with built-in humidity control and display. This thermostat combines both humidity and dry bulb into one. Fully programmable with night setback. Controls CO2 Sensing The CO2 sensor shall have the ability to monitor space occupancy levels within the building by measuring the parts per million of CO2 (Carbon Dioxide) in the air. As the CO2 levels increase, the outside air damper modulates to meet the CO2 space ventilation requirements. The CO2 accessory shall be available as field installed. Digital Display Touchscreen Programmable Programmable Thermostat (2H/2C) Thermostat (2H/2C) 5� b ii°29 S2 n m O O O Two Heat/Two Cool digital display thermostat. 7-day programmable stat with night setback shall be available. gM7j Two Heat/Two Cool programmable thermostat with touch screen digital display. Menu -driven programming. Effortless set-up. Program each day separately with no need to copy multiple days. All programming can be done on one screen. Easy to read and use. Large, clear backlit digital display. RT-PRCO23-EN 149 0 M WE' Controls Digital Display Thermostat (31-1/2C) Three Heat, Two Cool digital display thermostat. Easy access battery replacement. Flip -out door for easy battery replacement without removing or disassembling the 17090 thermostat. Dual Thermistor Remote Zone Sensor This sensor will allow the customer to reduce the total number of remote sensors to obtain space temperature averaging. This sensor should be utilized with ReliaTel controls. RA Remote Sensor Return Air Remote Sensor which can be mounted in the return air duct to report return air temperature. Room Remote Sensor Space Remote Sensor which can be mounted on the wall to report/control from a remote location in the space. 150 RT-PRCO23-EN 0 TRANE' Electrical Data Table 128. Unit wiring - standard efficiency Standard Indoor Fan Motor(a) Oversized Indoor Fan Motor Max Fuse Size Max Fuse Size Unit Model Voltage or Max Circuit or Max Circuit Tons Number Range MCA Breaker MCA Breaker 3 T/YSC036E1 187-253 27.2 40 - - 3 T/YSC036E3 187-253 21.4 30 - - 3 T/YSC036E4 414-506 10.1 15 - - 3 T/YSC036EW 517-633 8.0 15 - - 4 T/YSC048EI 187-253 35.2 50 - - 4 T/YSC048E3 187-253 25.2 35 - - 4 T/YSC048E4 414-506 12.5 15 - - 4 T/YSC048EW 517-633 9.0 15 - - 5 T/YSC060E1 187-253 43.8 70 - - 5 T/YSC060E3 187-253 29.5 45 - - 5 T/YSC060E4 414-506 15.5 25 - - 5 T/YSC060EW 517-633 10.1 15 - - 6 T/YSC072E3 187-253 36.5 50 37.8 60 6 T/YSC072E4 414-506 18.2 25 18.8 25 6 T/YSC072EW 517-633 12.7 20 13.5 20 71/2(b) T/YSC092E3 187-253 43.3 50 46.4 60 71/2(b) T/YSC092E4 414-506 21.5 25 23.0 30 71/2(b) T/YSC092EW 517-633 15.9 20 17.1 20 81/2 T/YSC102E3 187-253 46.3 60 49.4 60 81/2 T/YSC102E4 414-506 21.9 25 23.4 30 81/2 T/YSC102EW 517-633 17.5 20 18.7 20 10 T/YSC120E3 187-253 55.9 60 59.9 60 10 T/YSC120E4 414-506 26.5 35 28.5 35 10 T/YSC120EW 517-633 21.2 25 22.9 30 3 WSC036E1 187-253 31.2 45 - - 3 WSC036E3 187-253 23.8 35 - - 3 WSC036E4 414-506 11.4 15 - - 3 WSC036EW 517-633 8.8 15 - - 4 WSC048EI 187-253 38.9 60 - - 4 WSC048E3 187-253 27.5 40 - - 4 WSC048E4 414-506 12.3 15 - - 4 WSC048EW 517-633 9.5 15 - - 5 WSC060E1 187-253 44.6 70 - - 5 WSC060E3 187-253 30.2 45 - - 5 WSC060E4 414-506 14.7 20 - - 5 WSC060EW 517-633 11.0 15 - - (a) No optional motors available for 3-5 tons. The standard motor for the 1-phase models is a Multispeed Direct Drive Motor. The standard motor for the 3-phase models is a Belt Drive Motor. (b) Dual refrigeration system. RT-PRCO23-EN 151 TRAWE WF Electrical Data Table 129. Unit wiring with electric heat (single point connection) - standard efficiency Standard Indoor Motor Oversized Indoor Motor Max Fuse Size or Max Fuse Size or Unit Model Heater Model Heater kW Control Max Circuit Max Circuit Tons Number Number Rating(a) Stages MCA Breaker MCA Breaker 208/230 Volts Single Phase 3 TSC036E1 BAYHTRE105* 3.8/5.0 1 30.1/33.5 40.0/40.0 — — 3 TSC036E1 BAYHTRE110* 7.5/10.0 2 52.6/59.6 60.0/60.0 — — 3 TSC036E1 BAYHTRE114* 10.4/13.8 2 69.8/79.4 70.0/80.0 — — 4 TSC048E1 BAYHTRE105* 3.8/5.0 1 35.2/35.5 50.0/50.0 — — 4 TSC048E1 BAYHTRE110* 7.5/10.0 2 54.6/61.6 60.0/70.0 — — 4 TSC048E1 BAYHTRE114* 10.4/13.8 2 71.8/81.4 80.0/90.0 — — 4 TSC048E1 BAYHTRE118* 13.2/17.6 2 89.0/101.1 90.0/110.0 — — 5 TSC060E1 BAYHTRE105* 3.8/5.0 1 43.8/43.8 70.0/70.0 — — 5 TSC060E1 BAYHTRE110* 7.5/10.0 2 54.6/61.6 70.0/70.0 — — 5 TSC060E1 BAYHTRE114* 10.4/13.8 2 71.8/81.4 80.0/90.0 — — 5 TSC060E1 BAYHTRE118* 13.2/17.6 2 89.0/101.1 90.0/110.0 — — 208/230 Volts Three Phase 3 TSC036E3 BAYHTRE306* 4.5/6.0 1 21.9/24.3 30.0/30.0 — — 3 TSC036E3 BAYHTRE312* 9.0/12.0 2 37.5/42.4 40.0/45.0 — — 3 TSC036E3 BAYHTRE318* 13.1/17.4 2 51.6/58.6 60.0/60.0 — — 4 TSC048E3 BAYHTRE306* 4.5/6.0 1 25.2/25.2 35.0/35.0 — — 4 TSC048E3 BAYHTRE312* 9.0/12.0 2 37.5/42.4 40.0/45.0 — — 4 TSC048E3 BAYHTRE318* 13.1/17.4 2 51.6/58.6 60.0/60.0 — — 5 TSC060E3 BAYHTRE306* 4.5/6.0 1 29.5/29.5 45.0/45.0 — — 5 TSC060E3 BAYHTRE312* 9.0/12.0 2 37.5/42.4 45.0/45.0 — — 5 TSC060E3 BAYHTRE318* 13.1/17.4 2 51.6/58.6 60.0/60.0 — — 5 TSC060E3 BAYHTRE323* 17.3/23.0 2 66.3/75.4 70.0/80.0 — — 6 TSC072E3 BAYHTRS309* 6.8/9.0 1 36.5/36.5 50/50 37.8/37.8 60/60 6 TSC072E3 BAYHTRS318* 13.5/18.0 1 53.1/60.4 60/70 54.8/62.0 60/70 6 TSC072E3 BAYHTRS327* 20.3/27.0 2 76.6/87.5 80/90 78.3/89.1 80/90 6 TSC072E3 BAYHTRS336* 27.0/36.0 2 100.1/114.5 110/125 101.8/116.1 110/125 71/2(b) TSC092E3 BAYHTRT309* 6.8/9.0 1 43.3/43.3 50/50 46.4/46.4 60/60 71/2(b) TSC092E3 BAYHTRT318* 13.5/18.0 1 54.8/62.0 60/70 58.6/65.9 60/70 71/2(b) TSC092E3 BAYHTRT327* 20.3/27.0 2 78.3/89.1 80/90 82.1/93.0 90/100 71/2(b) TSC092E3 BAYHTRT336* 27.0/36.0 2 101.8/116.1 110/125 105.6/120.0 110/125 8.5 TSC102E3 BAYHTRT309* 6.8/9.0 1 46.3/46.3 60/60 49.4/49.4 60/60 8.5 TSC102E3 BAYHTRT318* 13.5/18.0 1 54.8/62.0 60/70 58.6/65.9 60/70 8.5 TSC102E3 BAYHTRT327* 20.3/27.0 2 78.3/89.1 80/90 82.1/93.0 90/100 8.5 TSC102E3 BAYHTRT336* 27.0/36.0 2 101.8/116.1 110/125 105.6/120.0 110/125 10 TSC120E3 BAYHTRT318* 13.5/18.0 1 58.6/65.9 60/70 63.6/70.9 80/80 10 TSC120E3 BAYHTRT327* 20.3/27.0 2 82.1/93.0 90/100 87.1/98.0 90/100 10 TSC120E3 BAYHTRT336* 27.0/36.0 2 105.6/120.0 110/125 110.6/125.0 125/125 10 TSC120E3 BAYHTRT354* 40.6/54.0 2 152.5/141.7 175/150 157.5/146.7 175/150 continued on next page 152 RT-PRCO23-EN A TRANE Electrical Data Table 129. Unit wiring with electric heat (single point connection) - standard efficiency (continued) Standard Indoor Motor Oversized Indoor Motor Max Fuse Size or Max Fuse Size or Unit Model Heater Model Heater kW Control Max Circuit Max Circuit Tons Number Number Rating(a) Stages MCA Breaker MCA Breaker 480 Volts Three Phase 3 TSC036E4 BAYHTRE406* 6.0 1 12.1 15.0 - - 3 TSC036E4 BAYHTRE412* 12.0 2 21.1 25.0 - - 3 TSC036E4 BAYHTRE418* 17.4 2 29.3 30.0 - - 4 TSC048E4 BAYHTRE406* 6.0 1 12.5 15.0 - - 4 TSC048E4 BAYHTRE412* 12.0 2 21.1 25.0 - - 4 TSC048E4 BAYHTRE418* 17.4 2 29.3 30.0 - - 5 TSC060E4 BAYHTRE406* 6.0 1 15.5 25.0 - - 5 TSC060E4 BAYHTRE412* 12.0 2 21.1 25.0 - - 5 TSC060E4 BAYHTRE418* 17.4 2 29.3 30.0 - - 5 TSC060E4 BAYHTRE423* 23.0 2 37.8 40.0 - - 6 TSC072E4 BAYHTRS409* 9.0 1 18.2 25 18.8 25 6 TSC072E4 BAYHTRS418* 18.0 1 30.3 35 31.0 35 6 TSC072E4 BAYHTRS427* 27.0 2 43.8 45 44.5 45 6 TSC072E4 BAYHTRS436* 36.0 2 57.3 60 58.0 60 71/2(b) TSC092E4 BAYHTRT409* 9.0 1 21.5 25 23.0 30 71/2(b) TSC092E4 BAYHTRT418* 18.0 1 31.0 35 32.9 35 71/2(b) TSC092E4 BAYHTRT427* 27.0 2 44.5 45 46.4 50 71/2(b) TSC092E4 BAYHTRT436* 36.0 2 58.0 60 59.9 60 81/2 TSC102E4 BAYHTRT409* 9.0 1 21.9 25 23.4 30 81/2 TSC102E4 BAYHTRT418* 18.0 1 31.0 35 32.9 35 81/2 TSC102E4 BAYHTRT427* 27.0 2 44.5 45 46.4 50 81/2 TSC102E4 BAYHTRT436* 36.0 2 58.0 60 59.9 60 10 TSC120E4 BAYHTRT418* 18.0 1 32.9 35 35.4 40 10 TSC120E4 BAYHTRT427* 27.0 2 46.4 50 48.9 50 10 TSC120E4 BAYHTRT436* 36.0 2 59.9 60 62.4 70 10 TSC120E4 BAYHTRT454* 54.0 2 70.8 80 73.3 80 575 Volts Three Phase 3 TSC036EW BAYHTREW06* 6.0 1 9.4 15.0 - - 3 TSC036EW BAYHTREWI2* 12.0 2 16.5 20.0 - - 3 TSC036EW BAYHTREWI8* 17.4 2 23.0 25.0 - - 4 TSC048EW BAYHTREW06* 6.0 1 9.4 15.0 - - 4 TSC048EW BAYHTREWI2* 12.0 2 16.5 20.0 - - 4 TSC048EW BAYHTREWI8* 17.4 2 23.0 25.0 - - 5 TSC060EW BAYHTREW06* 6.0 1 10.1 15.0 5 TSC060EW BAYHTREWI2* 12.0 2 16.5 20.0 5 TSC060EW BAYHTREWI8* 17.4 2 23.0 25.0 5 TSC060EW BAYHTREW23* 23.0 2 29.8 30.0 6 TSC072EW BAYHTRSW09* 9.0 1 13.0 20 14.0 20 6 TSC072EW BAYHTRSWI8* 18.0 1 23.8 25 24.8 25 6 TSC072EW BAYHTRSW27* 27.0 2 34.6 35 35.6 40 continued on next page RT-PRCO23-EN 153 TRAWE WF Electrical Data Table 129. Unit wiring with electric heat (single point connection) - standard efficiency (continued) Standard Indoor Motor Oversized Indoor Motor Max Fuse Size or Max Fuse Size or Unit Model Heater Model Heater kW Control Max Circuit Max Circuit Tons Number Number Rating(a) Stages MCA Breaker MCA Breaker 6 TSC072EW BAYHTRSW36* 36.0 2 45.4 50 46.4 50 71/2(b) TSC092EW BAYHTRTWI8* 18.0 1 24.8 25 26.3 30 71/2(b) TSC092EW BAYHTRTW27* 27.0 2 35.6 40 37.1 40 71/2(b) TSC092EW BAYHTRTW36* 36.0 2 46.4 50 47.9 50 81/2 TSC102EW BAYHTRTWI8* 18.0 1 24.8 25 26.3 30 81/2 TSC102EW BAYHTRTW27* 27.0 2 35.6 40 37.1 40 81/2 TSC102EW BAYHTRTW36* 36.0 2 46.4 50 47.9 50 10 TSC120EW BAYHTRTWI8* 18.0 1 26.3 30 28.4 30 10 TSC120EW BAYHTRTW27* 27.0 2 37.1 40 39.3 40 10 TSC120EW BAYHTRTW36* 36.0 2 47.9 50 50.0 50 10 TSC120EW BAYHTRTW54* 54.0 2 56.6 60 58.8 60 208/230 Volts Single Phase 3 WSC036E1 BAYHTRE105* 3.8/5.0 1 53.9/57.2 60.0/70.0 - - 3 WSC036E1 BAYHTRE110* 7.5/10.0 2 76.4/83.4 80.0/90.0 - - 3 WSC036E1 BAYHTRE114* 10.4/13.8 2 93.5/103.1 100.0/110.0 - - 4 WSC048E1 BAYHTRE105* 3.8/5.0 1 61.6/64.9 80.0/80.0 - - 4 WSC048E1 BAYHTRE110* 7.5/10.0 2 84.1/91.1 90.0/100.0 - - 4 WSC048E1 BAYHTRE114* 10.4/13.8 2 101.2/110.8 110.0/125.0 4 WSC048E1 BAYHTRE118* 13.2/17.6 2 118.4/130.6 125.0/150.0 - - 5 WSC060E1 BAYHTRX105* 3.8/5.0 1 67.2/70.6 90.0/90.0 - - 5 WSC060E1 BAYHTRX110* 7.5/10.0 2 89.7/96.7 100.0/110.0 - - 5 WSC060E1 BAYHTRX114* 10.4/13.8 2 106.8/116.4 110.0/125.0 - - 5 WSC060E1 BAYHTRX118* 13.2/17.6 2 124.1/136.2 125.0/150.0 - - 208/230 Volts Three Phase 3 WSC036E3 BAYHTRE306* 4.5/6.0 1 39.5/41.8 45.0/50.0 - - 3 WSC036E3 BAYHTRE312* 9.0/12.0 2 55.1/60.0 60.0/60.0 - - 3 WSC036E3 BAYHTRE318* 13.1/17.4 2 69.2/76.2 70.0/80.0 - - 4 WSC048E3 BAYHTRE306* 4.5/6.0 1 43.2/45.5 50.0/50.0 - - 4 WSC048E3 BAYHTRE312* 9.0/12.0 2 58.8/63.7 60.0/70.0 - - 4 WSC048E3 BAYHTRE318* 13.1/17.4 2 72.9/79.9 80.0/80.0 - - 5 WSC060E3 BAYHTRX306* 4.5/6.0 1 45.8/48.2 60.0/60.0 - - 5 WSC060E3 BAYHTRX312* 9.0/12.0 2 61.4/66.3 70.0/70.0 - - 5 WSC060E3 BAYHTRX318* 13.1/17.4 2 75.6/82.6 80.0/90.0 - - 5 WSC060E3 BAYHTRX323* 17.3/23.0 2 90.2/99.3 100.0/100.0 - - 480 Volts Three Phase 3 WSC036E4 BAYHTRE406* 6.0 1 20.4 25.0 - - 3 WSC036E4 BAYHTRE412* 12.0 2 29.4 30.0 - - 3 WSC036E4 BAYHTRE418* 17.4 2 37.5 40.0 - - 4 WSC048E4 BAYHTRE406* 6.0 1 21.3 25.0 - - 4 WSC048E4 BAYHTRE412* 12.0 2 30.3 35.0 - - 4 WSC048E4 BAYHTRE418* 17.4 2 38.4 40.0 - - continued on next page 154 RT-PRCO23-EN A TRANE Electrical Data Table 129. Unit wiring with electric heat (single point connection) - standard efficiency (continued) Standard Indoor Motor Oversized Indoor Motor Max Fuse Size or Max Fuse Size or Unit Model Heater Model Heater kW Control Max Circuit Max Circuit Tons Number Number Rating(a) Stages MCA Breaker MCA Breaker 5 WSC060E4 BAYHTRX406* 6.0 1 23.7 30.0 - - 5 WSC060E4 BAYHTRX412* 12.0 2 32.7 35.0 - - 5 WSC060E4 BAYHTRX418* 17.4 2 40.8 45.0 - - 5 WSC060E4 BAYHTRX423* 23.0 2 49.3 50.0 - - 575 Volts Three Phase 3 WSC036EW BAYHTREW06* 6.0 1 16.1 20.0 - - 3 WSC036EW BAYHTREWI2* 12.0 2 23.2 25.0 - - 3 WSC036EW BAYHTREWI8* 17.4 2 29.7 30.0 - - 4 WSC048EW BAYHTREW06* 6.0 1 16.7 20.0 - - 4 WSC048EW BAYHTREWI2* 12.0 2 23.8 25.0 - - 4 WSC048EW BAYHTREWI8* 17.4 2 30.3 35.0 - - 5 WSC060EW BAYHTRXW06* 6.0 1 18.2 20.0 - - 5 WSC060EW BAYHTRXWI2* 12.0 2 25.4 30.0 - - 5 WSC060EW BAYHTRXWI8* 17.4 2 31.9 35.0 - - 5 WSC060EW BAYHTRXW23* 23.0 2 38.6 40.0 - - (a) No optional motors available for 3-5 tons. The standard motor for 1-phase models is a Multispeed, Direct Drive Motor. The Standard Motor for the 3- phase models is a Belt Drive Motor. (b) Dual refrigeration system. Table 130. Electrical characteristics - compressor motor and condenser motor- 60 cycle - standard efficiency Compressor Motors Condenser Fan Motors Unit Model Amps(a) Amps(a) Tons Number No. Volts Phase hp(b) rpm RLA LRA No. Volts Phase hp FLA LRA 3 T/YSC036E1 1 208-230 1 2.8 3500 15.4 83.0 1 208-230 1 0.33 2.0 6.6 3 T/YSC036E3 1 208-230 3 2.8 3500 11.5 77.0 1 208-230 1 0.33 2.0 6.6 3 T/YSC036E4 1 460 3 2.7 3500 5.1 35.0 1 460 1 0.33 1.2 2.5 3 T/YSC036EW 1 575 3 2.8 3500 4.3 31.0 1 575 1 0.33 0.9 1.3 4 T/YSC048E1 1 208-230 1 3.6 3500 20.5 109.0 1 208-230 1 0.33 2.0 6.6 4 T/YSC048E3 1 208-230 3 3.6 3500 14.6 91.0 1 208-230 1 0.33 2.0 6.6 4 T/YSC048E4 1 460 3 3.6 3500 7.1 46.0 1 460 1 0.33 1.2 2.5 4 T/YSC048EW 1 575 3 3.5 3500 5.1 34.0 1 575 1 0.33 0.9 1.3 5 T/YSC060E1 1 208-230 1 4.4 3500 26.9 145.0 1 208-230 1 0.40 2.5 6.6 5 T/YSC060E3 1 208-230 3 4.3 3500 17.6 123.0 1 208-230 1 0.40 2.5 6.6 5 T/YSC060E4 1 460 3 4.3 3500 9.6 62.0 1 460 1 0.40 1.0 2.8 5 T/YSC060EW 1 575 3 4.3 3500 6.1 40.0 1 575 1 0.40 0.8 2.0 6 T/YSC072E3 1 208-230 3 5.6 3500 22.4 149.0 1 208-230 1 .70 3.5 10.9 6 T/YSC072E4 1 460 3 5.6 3500 10.6 75.0 1 460 1 .70 2.4 6.6 6 T/YSC072EW 1 575 3 5.6 3500 7.7 54.0 1 575 1 .70 1.4 3.60 71/2 T/YSC092E3 2 208-230 3 3.7/3.1 3500/3500 11.9/10.2 91.0/88.0 1 208-230 1 .70 3.5 10.9 71/2 T/YSC092E4 2 460 3 3.7/3.1 3500/3500 7.1/7.1 46.0/46.0 1 460 1 .70 2.4 6.6 71/2 T/YSC092EW 2 575 3 3.7/3.1 3500/3500 5.6/5.0 34.0/34.0 1 575 1 .70 1.4 3.60 continued on next page RT-PRCO23-EN 155 TRAWE WF Electrical Data Table 130. Electrical characteristics - compressor motor and condenser motor- 60 cycle - standard efficiency (continued) Compressor Motors Condenser Fan Motors Unit Model Amps(a) Amps(a) Tons Number No. Volts Phase hp(b) rpm RLA LRA No. Volts Phase hp FLA LRA 81/2 T/YSC102E3 2 208-230 3 3.7/3.7 3500/3500 16/16 91.0/96.0 1 208-230 1 .75 4.0 9.4 81/2 T/YSC102E4 2 460 3 3.7/3.7 3500/3500 7.1/7.1 46.0/46.0 1 460 1 .75 2.8 6.8 81/2 T/YSC102EW 2 575 3 3.7/3.7 3500/3500 5.6/5.6 37.0/37.0 1 575 1 .75 2.4 6.2 10 T/YSC120E3 2 208-230 3 4.8/3.7 3500/3500 20.5/16.9 155.0/91.0 1 208-230 1 .75 4.0 9.4 10 T/YSC120E4 2 460 3 4.8/3.7 3500/3500 9.6/7.1 75.0/46.0 1 460 1 .75 2.8 6.8 10 T/YSC120EW 2 575 3 4.8/3.7 3500/3500 7.6/5.6 54.0/37.0 1 575 1 .75 2.4 6.2 3 WSC036E1 1 208-230 1 3.2 3500 18.6 105.0 1 208-230 1 0.25 2.0 4.4 3 WSC036E3 1 208-230 3 3.2 3500 13.5 88.0 1 208-230 1 0.25 2.0 4.4 3 WSC036E4 1 460 3 3.2 3500 6.4 39.0 1 460 1 0.25 0.9 2.2 3 WSC036EW 1 575 3 3.2 3500 5.1 34.0 1 575 1 0.25 0.7 1.4 4 WSC048E1 1 208-230 1 3.8 3500 23.1 134.0 1 208-230 1 0.40 2.5 6.6 4 WSC048E3 1 208-230 3 3.8 3500 16.0 91.0 1 208-230 1 0.40 2.5 6.6 4 WSC048E4 1 460 3 3.8 3500 7.1 46.0 1 460 1 0.40 1.0 2.8 4 WSC048EW 1 575 3 3.8 3500 5.6 37.0 1 575 1 0.40 0.8 2.0 5 WSC060E1 1 208-230 1 4.8 3500 27.6 158.0 1 208-230 1 0.40 2.5 6.6 5 WSC060E3 1 208-230 3 4.7 3500 18.1 137.0 1 208-230 1 0.40 2.5 6.6 5 WSC060E4 1 460 3 4.7 3500 9.0 62.0 1 460 1 0.40 1.0 2.8 5 WSC060EW 1 575 3 4.7 3500 6.8 50.0 1 575 1 0.40 0.8 2.0 (a) Amp draw for each motor; multiply value by number of motors to determine total amps. (b) hp for each compressor. Table 131. Electrical characteristics - standard evaporator fan motor- 60 cycle - direct or belt drive standard efficiency Unit Model Direct or Belt Amps Tons Number Drive No. Volts Phase hp FLA LRA 3 T/YSC036E1 Direct Drive 1 208-230 1 0.75 6.0 - 3 T/YSC036E3 Belt Drive 1 208-230 3 1.00 5.0 32.2 3 T/YSC036E4 Belt Drive 1 460 3 1.00 2.5 16.1 3 T/YSC036EW Belt Drive 1 575 3 1.00 1.7 13.2 4 T/YSC048E1 Direct Drive 1 208-230 1 1.00 7.6 - 4 T/YSC048E3 Belt Drive 1 208-230 3 1.00 5.0 32.2 4 T/YSC048E4 Belt Drive 1 460 3 1.00 2.5 16.1 4 T/YSC048EW Belt Drive 1 575 3 1.00 1.7 13.2 5 T/YSC060E1 Direct Drive 1 208-230 1 1.00 7.6 - 5 T/YSC060E3 Belt Drive 1 208-230 3 1.00 5.0 32.2 5 T/YSC060E4 Belt Drive 1 460 3 1.00 2.5 16.1 5 T/YSC060EW Belt Drive 1 575 3 1.00 1.7 13.2 6 T/YSC072E3 Belt Drive 1 208-230 3 1.00 5.00 32.20 6 T/YSC072E4 Belt Drive 1 460 3 1.00 2.50 16.10 6 T/YSC072EW Belt Drive 1 575 3 1.00 1.70 13.20 71/2 T/YSC092E3 Belt Drive 1 208-230 3 2.00 6.30 48.00 71/2 T/YSC092E4 Belt Drive 1 460 3 2.00 3.10 24.00 continued on next page 156 RT-PRCO23-EN TRANE Electrical Data Table 131. Electrical characteristics - standard evaporator fan motor- 60 cycle - direct or belt drive standard efficiency (continued) Unit Model Direct or Belt Amps Tons Number Drive No. Volts Phase hp FLA LRA 71/2 T/YSC092EW Belt Drive 1 575 3 2.00 2.50 18.20 81/2 T/YSC102E3 Belt Drive 1 208-230 3 2.00 6.30 48.00 81/2 T/YSC102E4 Belt Drive 1 460 3 2.00 3.10 24.00 81/2 T/YSC102EW Belt Drive 1 575 3 2.00 2.50 18.20 10 T/YSC120E3 Belt Drive 1 208-230 3 3.00 9.40 83.00 10 T/YSC120E4 Belt Drive 1 460 3 3.00 4.60 42.00 10 T/YSC120EW Belt Drive 1 575 3 3.00 3.70 31.00 3 WSC036E1 Direct Drive 1 208-230 1 0.75 6.0 - 3 WSC036E3 Belt Drive 1 208-230 3 1.00 5.0 32.2 3 WSC036E4 Belt Drive 1 460 3 1.00 2.5 16.1 3 WSC036EW Belt Drive 1 575 3 1.00 1.7 13.2 4 WSC048E1 Direct Drive 1 208-230 1 1.00 7.6 - 4 WSC048E3 Belt Drive 1 208-230 3 1.00 5.0 32.2 4 WSC048E4 Belt Drive 1 460 3 1.00 2.5 16.1 4 WSC048EW Belt Drive 1 575 3 1.00 1.7 13.2 5 WSC060E1 Direct Drive 1 208-230 1 1.00 7.6 - 5 WSC060E3 Belt Drive 1 208-230 3 1.00 5.0 32.2 5 WSC060E4 Belt Drive 1 460 3 1.00 2.5 16.1 5 WSC060EW Belt Drive 1 575 3 1.00 1.7 13.2 Table 132. Electrical characteristics - oversized evaporator fan motor- 60 cycle - belt drive - standard efficiency Unit Model Amps Tons Number No. Volts Phase hp FLA LRA 6 T/YSC072E3 1 208-230 3 2.00 6.30 48.00 T/YSC072E4 1 460 3 2.00 3.10 24.00 T/YSC072EW 1 575 3 2.00 2.50 18.20 71/2 T/YSC092E3 1 208-230 3 3.00 9.40 83.00 T/YSC092E4 1 460 3 3.00 4.60 42.00 T/YSC092EW 1 575 3 3.00 3.70 31.00 81/2 T/YSC102E3 1 208-230 3 3.00 9.40 83.00 T/YSC102E4 1 460 3 3.00 4.60 42.00 T/YSC102EW 1 575 3 3.00 3.70 31.00 10 T/YSC120E3 1 208-230 3 5.00 13.40 112.00 T/YSC120E4 1 460 3 5.00 6.60 56.00 T/YSC120EW 1 575 3 5.00 5.40 44.00 Table 133. Electrical characteristics - power exhaust (cooling and gas/electric) Tons Volts Phase hp rpm(a) FLA LRA 6-10 208-230 1 0.87 1075 5.7 16.3 6-10 460 1 0.87 1075 3.3 6.8 6-10 575 1 0.87 1075 2.3 5.4 (a) Two speed. RT-PRCO23-EN 157 TRAWE WF Electrical Data Table 134. Electrical characteristics - inducer motor Unit Model Number Stages hp rpm Volts Phase LRA YSC(036-060)E**(L,M,X,Y) 1 1/35 3000 208-230 1 0.6 YSC072E**(L,M,X,Y) 1 1/35 3000 208-230 1 0.6 YSC(092,102)E**(L,X) YSC072E**(H,Z) YSC(092,102)E**(M,H,Y,Z) 2 1/15 2800/3350 208-230 1 0.5 YSC120E**(L,M,H,X,Y,Z) YSC(036-060)E**(H,Z) 1 1/15 3300 208-230 1 0.4 Table 135. Unit wiring - high efficiency Standard Indoor Fan Motor Optional Belt Drive Indoor Fan Motor(a) Max Fuse Size Unit Model Voltage or Max Circuit Max Fuse Size Tons Number Range MCA Breaker MCA or Max Circuit Breaker 3 T/YHC036EI 187-253 26.7 40 (a) (a) T/YHC036E3 187-253 21.9 30 20.9 30 T/YHC036E4 414-506 10.0 15 9.5 15 4 T/YHC048E1 187-253 35.7 50 (a) (a) T/YHC048E3 187-253 28.3 40 25.7 40 T/YHC048E4 414-506 13.6 20 12.3 15 5 T/YHC060EI 187-253 43.8 70 (a) (a) T/YHC060E3 187-253 32.1 45 29.5 45 T/YHC060E4 414-506 16.8 25 15.5 25 (a) No optional motors available for 3-5 tons. The standard motor for the 1-phase models is a Multispeed Direct Drive Motor. Table 136. Unit wiring with electric heat (single point connection) - high efficiency Standard Optional Belt Drive Indoor Motor Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW Control or Max Circuit or Max Circuit Tons Number Number Rating(a) Stages MCA Breaker MCA Breaker 208/230 Volts Single Phase 3 THC036EI BAYHTRE105* 3.8/5.0 1 30.1/33.5 40.0/40.0 — — 3 THC036EI BAYHTRE110* 7.5/10.0 2 52.6/59.6 60.0/60.0 — — 3 THC036EI BAYHTRE114* 10.4/13.8 2 69.8/79.4 70.0/80.0 — — 4 THC048E1 BAYHTRX105* 3.8/5.0 1 35.7/35.7 50.0/50.0 — — 4 THC048E1 BAYHTRX110* 7.5/10.0 2 54.6/61.6 60.0/70.0 — — 4 THC048EI BAYHTRX114* 10.4/13.8 2 71.8/81.4 80.0/90.0 — — 4 THC048EI BAYHTRX118* 13.2/17.6 2 89.0/101.1 90.0/110.0 — — 5 THC060EI BAYHTRX105* 3.8/5.0 1 43.8/43.8 70.0/70.0 — — 5 THC060E1 BAYHTRX110* 7.5/10.0 2 54.6/61.6 70.0/70.0 — — 5 THC060E1 BAYHTRX114* 10.4/13.8 2 71.8/81.4 80.0/90.0 5 THC060E1 BAYHTRX118* 13.2/17.6 2 89.0/101.1 90.0/110.0 — — continued on next page 158 RT-PRCO23-EN A TRANE Electrical Data Table 136. Unit wiring with electric heat (single point connection) - high efficiency (continued) Standard Optional Belt Drive Indoor Motor Indoor Motor Max Fuse Size Max Fuse Size Unit Model Heater Model Heater kW Control or Max Circuit or Max Circuit Tons Number Number Rating(a) Stages MCA Breaker MCA Breaker 208/230 Volts Three Phase 3 THC036E3 BAYHTRE306* 4.5/6.0 1 23.1/25.5 30.0/30.0 21.9/24.3 30.0/30.0 3 THC036E3 BAYHTRE312* 9.0/12.0 2 38.8/43.6 40.0/45.0 37.5/42.4 40.0/45.0 3 THC036E3 BAYHTRE318* 13.1/17.4 2 52.9/59.9 60.0/60.0 51.6/58.6 60.0/60.0 4 THC048E3 BAYHTRX306* 4.5/6.0 1 28.3/28.3 40.0/40.0 25.7/25.7 40.0/40.0 4 THC048E3 BAYHTRX312* 9.0/12.0 2 40.8/45.6 45.0/50.0 37.5/42.4 40.0/45.0 4 THC048E3 BAYHTRX318* 13.1/17.4 2 54.9/61.9 60.0/70.0 51.6/58.6 60.0/60.0 5 THC060E3 BAYHTRX306* 4.5/6.0 1 32.1/32.1 45.0/45.0 29.5/29.5 45.0/45.0 5 THC060E3 BAYHTRX312* 9.0/12.0 2 40.8/45.6 45.0/50.0 37.5/42.4 45.0/45.0 5 THC060E3 BAYHTRX318* 13.1/17.4 2 54.9/61.9 60.0/70.0 51.6/58.6 60.0/60.0 5 THC060E3 BAYHTRX323* 17.3/23.0 2 69.5/78.6 70.0/80.0 66.3/75.4 70.0/80.0 460 Volts Three Phase 3 THC036E4 BAYHTRE406* 6.0 1 12.8 15.0 12.1 15.0 3 THC036E4 BAYHTRE412* 12.0 2 21.8 25.0 21.1 25.0 3 THC036E4 BAYHTRE418* 17.4 2 29.9 30.0 29.3 30.0 4 THC048E4 BAYHTRX406* 6.0 1 13.8 20.0 12.3 15.0 4 THC048E4 BAYHTRX412* 12.0 2 22.8 25.0 21.1 25.0 4 THC048E4 BAYHTRX418* 17.4 2 30.9 35.0 29.3 30.0 5 THC060E4 BAYHTRX406* 6.0 1 16.8 25.0 15.5 25.0 5 THC060E4 BAYHTRX412* 12.0 2 22.8 25.0 21.1 25.0 5 THC060E4 BAYHTRX418* 17.4 2 30.9 35.0 29.3 30.0 5 THC060E4 BAYHTRX423* 23.0 2 39.4 40.0 37.8 40.0 (a) Heater kW ratings are at 208/240V for 208/230V units, 480V for 460V units. Table 137. Electrical characteristics - compressor motor and condenser fan motor - 60 cycle - high efficiency Unit Model Compressor Motors Condenser Fan Motors Tons Number No. Volts Phase hp rpm RLA LRA No. Volts Phase hp FLA LRA 3 T/YHC036E1 1 208-230 1 2.8 3500 15.4 83.0 1 208-230 1 0.20 1.5 2.4 T/YHC036E3 1 208-230 3 2.8 3500 11.5 77.0 1 208-230 1 0.20 1.5 2.4 T/YHC036E4 1 460 3 2.7 3500 5.1 35.0 1 460 1 0.20 0.6 1.3 4 T/YHC048E1 1 208-230 1 3.6 3500 20.5 109.0 1 208-230 1 0.40 2.5 6.6 T/YHC048E3 1 208-230 3 3.6 3500 14.6 91.0 1 208-230 1 0.40 2.5 6.6 T/YHC048E4 1 460 3 3.6 3500 7.1 46.0 1 460 1 0.40 1.0 2.8 5 T/YHC060E1 1 208-230 1 4.4 3500 26.9 145.0 1 208-230 1 0.40 2.5 6.6 T/YHC060E3 1 208-230 3 4.3 3500 17.6 123.0 1 208-230 1 0.40 2.5 6.6 T/YHC060E4 1 460 3 4.3 3500 9.6 62.0 1 460 1 0.40 1.0 2.8 RT-PRCO23-EN 159 TRAWE WF Electrical Data Table 138. Electrical characteristics - evaporator fan motor- 60 cycle - direct drive - high efficiency Unit Model Tons Number Volts Hz. Phase No. FLA LRA bhp 3 T/YHC036E1 208-230 60 1 1 6.0 - 0.75 3 T/YHC036E3 208-230 60 1 1 6.0 - 0.75 3 T/YHC036E4 460 60 1 1 6.0 - 0.75 4 T/YHC048E1 208-230 60 1 1 7.6 - 1.00 4 T/YHC048E3 208-230 60 1 1 7.6 - 1.00 4 T/YHC048E4 460 60 1 1 7.6 - 1.00 5 T/YHC060E1 208-230 60 1 1 7.6 - 1.00 5 T/YHC060E3 208-230 60 1 1 7.6 - 1.00 5 T/YHC060E4 460 60 1 1 7.6 - 1.00 Table 139. Electrical characteristics - evaporator fan motor- 60 cycle - optional belt drive - high efficiency Unit Model Tons Number Volts Hz. Phase No. FLA LRA bhp 3 T/YHC036E3 208-230 60 3 1 5.0 32.2 1.00 3 T/YHC036E4 460 60 3 1 2.5 16.1 1.00 4 T/YHC048E3 208-230 60 3 1 5.0 32.2 1.00 4 T/YHC048E4 460 60 3 1 2.5 16.1 1.00 5 T/YHC060E3 208-230 60 3 1 5.0 32.2 1.00 5 T/YHC060E4 460 60 3 1 2.5 16.1 1.00 Table 140. Electrical characteristics - power exhaust (cooling and gas/electric) Tons Volts Phase hp rpm(a) FLA LRA 6-10 208-230 1 0.87 1075 5.7 16.3 6-10 460 1 0.87 1075 3.3 6.8 6-10 575 1 0.87 1075 2.3 5.4 (a) Two Speed. Table 141. Electrical characteristics - inducer motor Unit Model Number Stages hp rpm Volts Phase LRA YHC036E(L,M,X,Y) 1 1/35 3000 208-230 1 0.6 YHC(048,060)E YHC036E(H,Z) 1 1/15 3300 208-230 1 0.4 160 RT-PRCO23-EN Jobsite Connections Table 142.Typical Number of Wires Zone Sensors A Manual Changeover ............................. 4 Manual/Auto Changeover ...................... 5 Manual/Auto Changeover with Status Indication LED's......................... 10 Programmable Night Setback with Status Indication LED's................... 7 Thermostats A 3 Wires, 24V, Cooling only 4 Wires, 24V, with Electric Heat B 3 Power Wires + 1 Ground Wire (3-phase) 2 Power Wires + 1 Ground Wire (1-phase) DISCONNECT SWITCH (BY OTHERS) B ZONE SENSOR OR O THERMOSTAT — ROOFTOP UNIT 0 TRANE' For specific wiring information, see the installation instructions. All wiring except power wire is low voltage. All customer supplied wiring to be copper and must conform to applicable electrical codes (such as NEC or CEC) and local electric codes. Wiring shown dotted is to be furnished and installed by the customer. RT-PRCO23-EN 161 0 TRANE' Dimensional Data Figure 3. Cooling and gas/electric - 3-5 tons standard efficiency; cooling and gas/electric; 3 tons high efficiency; heat pump - 3-4 tons standard efficiency Notes: 1. All dimensions are in inches/millimeters. 2. 1/2 NPT Gas Connection = (Y_C Models only); 2" Electrical Connection: Single Point Power When Heat Installed (T_C Models only.) —TOP PANEL EVAPORATOR SECTION ACCESS PANEL CONDENSER FAN 36 1/44 921 MM 4 1/4" 108 M ALTERNATE CONDENSATE DRAIN $14 -14 NPT DIA. HOLE CONDENSER COIL UNITCONTROL WIRE ® 7/S' (22MM) DIA. HOLE 23 9/16" 69 I/1 598 MM SERVICE GAUGE PORT ACCESS 1 SAS' (35MM) DIA. HOLE 69 8MM 42 108M M• 174107 M / UNITPOWERWIRE 1549i 16 2' (51 MM) DIA. HOLE 143/MM—194/MM 1/2 NPT GAS CONNECTION CONTROL AND COMPRESSOR ACCESS PANEL Figure 4. Cooling and gas/electric - 3-5 tons standard efficiency; cooling and gas/electric - 3 tons high efficiency; heat pump - 3-4 tons standard efficiency - downflow airflow supply/return - through the base utilities Note: All dimensions are in inches/millimeters. 3518" 14^ 91/4" 151/2" 92 MM 356 MM 235 MM 394 MM 4" 102 MM rM 610 MM RETURN TBU CONDENSATE 27 16/MM� / J� f 941MM 23 1 /2" 597 MM THROUGH THROUGH THE BASE THE BASE GAS (Y_C MODELS ELECTRICAL ONLY) 162 RT-PRCO23-EN 0 rawE' Dimensional Data Figure 5. Cooling and gas/electric - 3-5 tons standard efficiency; cooling and gas/electric - 3 tons high efficiency; heat pump - 3-4 tons standard efficiency - horizontal airflow supply/return Note: All dimensions are in inches/millimeters. V4' PAPA Cif -1 N CC Q)N II1 i1N Figure 6. Cooling and gas/electric - 3-5 tons standard efficiency; cooling and gas/electric - 3 tons high efficiency; heat pump - 3-4 tons standard efficiency - unit clearance and roof opening Note: All dimensions are in inches/millimeters. CLEARANCE CLEARANCE 37" (940 MM) HORIZONTAL FLOW - 18"MM) DOWNFLOW 36" (914 MM)) TYPICAL ROOF OPENING CLEARANCE FROM TOP OF UNIT 72" 68 3/16' 40" 37""-� (1732 MM) (1016 MM) (940 MM) �� \ 441/2 (1130 MM) CLEARANCE 48" (1219 MM) CLEARANCE 36" (914 MM) RT-PRCO23-EN 163 0 M WE' Dimensional Data Figure 7. Cooling and gas/electric - 3-5 tons standard efficiency; cooling and gas/electric - 3 tons high efficiency; heat pump - 3-4 tons standard efficiency - roof curb Note: All dimensions are in inches/millimeters. C/�F9nn ��y" �443MM• 9'r9,r^/Ce C� 37 7 s MM 25 3/16' 14 9/l6' CF 86 951f9, 640 MM 370 MM f (IDS(/', 61 16. n 1568/MM 63 3/16' �v%'A7 263 MM J'C`O'P V n7 .0 1656 MM [� 356 MM \ �25 MM 44 MM C 1797/e 65 40 7/8' C'e 1670 MM MM 1038 MM �9�cF 52MM 05 3 MM 1 Mi 1(�/i� 512MM 3�r ��1�0.� �7 Figure 8. Cooling and gas/electric - 3-5 tons standard efficiency; cooling and gas/electric - 3 tons high efficiency; heat pump - 3-4 tons standard efficiency - downf low duct connections - field fabricated Note: All dimensions are in inches/millimeters. 24 3/ (619 K ALL FLANGES 1 1/4" (32 MM) 14" 356 MM 164 RT-PRCO23-EN 0 caws" Figure 9. Cooling and gas/electric - 3-5 tons standard efficiency; cooling and gas/electric - 3 tons high efficiency; heat pump - 3-4 tons standard efficiency - economizer, manual or motorized fresh air damper Note: All dimensions are in inches/millimeters. Figure 11. Cooling and gas/electric - 3-5 tons standard efficiency; cooling and gas/electric - 3 tons high efficiency; heat pump 3-4 tons standard efficiency - economizer & barometric relief damper hood Note: All dimensions are in inches/millimeters. Dimensional Data Figure 10. Cooling and gas/electric models - 3-5 tons standard efficiency; cooling and gas/electric models - 3 tons high efficiency; heat pump - 3-4 tons standard efficiency - swing diameter for hinged door(s) option Note: All dimensions are in inches/millimeters. �(CWAYM„ l 17 7i8" 16" (454 MM) (406 MM) gpplmablero 221/4' V_G ma4als only (565 MM) Figure 12. Gas/electric models - 3-5 tons standard efficiency; 3 tons high efficiency height of gas pipe required from inside base of unit to gas shut off assembly (factory provided) - Y_C models only Note: All dimensions are in inches/millimeters. I RT-PRCO23-EN 165 0 M WE' Dimensional Data Figure 13. Cooling and gas/electric 4-5 tons high efficiency; cooling and gas/electric - 6 tons standard efficiency heat pumps - 5 tons standard efficiency Note: All dimensions are in inches/millimeters. —TOP PANEL EVAPORATOR SECTION CONDENSER FAN ACCESS PANEL 40 7/8 1038 MM 4114 108 MM ALTERNATE CONDENSATE DRAIN CONNECTION 3/4-14 NPT DIA. HOLE 18 ire ® 470 MM 27 SW CONDENSER COIL 701 MM UNTTCONTROLWIRE ® 47 7/8' 7/8' (22MM) DIA. HOLE 88 Be 1216 MM 9 5M SERVICE GAUGE PORT ACCESS 2251 MA 2" MM d 41/4 13AT' (35MM) DIA. HOLE MM 108 MM UNTTPOWERWIRE 5 5/8 1 SAT' (35MM) DIA. HOLE 2' ELECTRICAL CONNECTION (SINGLE POINT POWER - WHEN HEAT INSTALLED) — CONTROLAND COMPRESSOR ACCESS PANEL Figure 14. Cooling and gas/electric 4-5 tons high efficiency; cooling and gas/electric - 6 tons standard efficiency; heat pumps - 5 tons - downflow airflow supply/return - through the base utilities Note: All dimensions are in inches/millimeters. 3 5/8' 92 MM 17 u, 9 7/S'y 17 I/2' 444 MM _I_5M MM 444 MM 4 \\ ]02 M4 RETURN SUPPLY 32 I/8' 1 33' 8l6_MM 838 MM THROUGH THE BASE CONDENSATE 106NM 27 5/S' 701 W 40 3/4' 1035 MM THROUGH THE ' 127 BASE ELECTRICAL 5 7/8 149 NM 10 7/8' 276 MM I 71 MM 1 6 1/2' 3 3/4' �165 MM 97 MN 166 RT-PRCO23-EN 0 caws" Dimensional Data Figure 15. Cooling and gas/electric 4-5 tons high efficiency; cooling and gas/electric 6 tons standard efficiency; heat pumps - 5 tons - horizontal airflow supply and return Note: All dimensions are in inches/millimeters. 4 1/4" 108 MP 3 7/8" 98 VIM �I 238 MM -- Return I 32 1 /4" 832MM supply 46314 19 1 /4" •23 718" 489 MM 606 MM 3/4-14 NPT DIA. HOLE CONDENSATE DRAIN 27 5/8" 701 MM 4 3/4" 120 W Figure 16. Cooling and gas/electric 4-5 tons high efficiency; cooling and gas/electric - 6 tons standard efficiency; heat pumps - 5 tons - unit clearance and roof opening Note: All dimensions are in inches/millimeters. CLEARANCE CLEARANCE 36" (914 MM) HORIZONTAL FLOW - 18" (457 MM) 4dP DOWNFLOW 36" (914 MM) / TYPICAL ROOF OPENING CLEARANCE FROM TOP OF UNIT 72" 46" \ 88 (1M 168 M) (1M 168 M) IVI \ (2251 MM) � 53 1 /4 / (1352 MM) CLEARANCE 48" (1219 MM) \� CLEARANCE 36" (914 MM) RT-PRCO23-EN 167 A TAWE Dimensional Data Figure 17. Cooling and gas/electric 4-5 tons high efficiency; cooling and gas/electric - 6 tons standard efficiency; heat pumps - 5 tons - roof curb Note: All dimensions are in inches/millimeters. 36. (0 czF 11q�9tiC P PN�,E 3/8 < R 1178 MM) A CL. Cam` � 3/g 1" (470 MM) /(873 MM) (25y) iy(165MM 8) 8 r r9fy C\/ �vFZN / <a7o /M�fA) 80 1/2• �S> **1 (356 MM) c2045 MM) 83 7/8• M� �` 5MM) (2130 MM) � 4, ) j . 1 • 1,0 (25MM) (443 MM) SVPQ� 4 3/8• r�Oti O� (873MM q 0 4 F9�q 8 I /2• , c2146 M) 49 C 7/�g c1267 MM) (51 MM) 50 8 C°i,A MM c' f9 36' (512MM) Figure 18. Cooling and gas/electric 4-5 tons high efficiency; cooling and gas/electric - 6 tons standard efficiency; heat pumps - 5 tons - downflow duct connections field fabricated Note: All dimensions are in inches/millimeters. 17 3/4" 451 MM 7 / 17 3/4" 451 MM 33 3/4" 857 MM ' 33 3/4" 1 857 MM ALL FLANGES 1 1/4" (31 MM) 168 RT-PRCO23-EN TRANE Dimensional Data Figure 19. Cooling and gas/electric 4-5 tons high efficiency; cooling and gas/electric - 6 tons standard efficiency; heat pumps - 5 tons - economizer, manual or motorized fresh air damper Note: All dimensions are in inches/millimeters. BAROMETRIC RELIEF HOOD (198 MM) 12.„ r 67/8" (304 M) (175 MM) 16 3/4" (425 MM)� CONOMIZER HOOD Figure 20. Cooling and gas/electric 4-5 tons high efficiency; cooling and gas/electric 6 tons standard efficiency; heat pumps - 5 tons - swing diameter for hinged door(s) option Note: All dimensions are in inches/millimeters. r � i �1 (432 MM) 21 3/8" (543 MM) 34 5/8" - - - - (879 MM) RT-PRCO23-EN 169 TRAMS WF Dimensional Data Figure 21. Cooling and gas/electric models - 71/2, 81/2 and 10 tons standard efficiency Note: All dimensions are in inches/millimeters. —TOP PANEL 108 MM ALTERNATE CONDENSATE DRAIN CONNECTION 3/4-14 NPT DIA. HOLE 241/2' ® 622 MM 275/8" CONDENSER COIL 701 MM UNIT CONTROL WIRE ILIA718. (22MM) DIA. HOLE 47 7/8" 88 5/8' 1216 MM 9 5/8 SERVICE GAUGE PORT ACCESS 2251 MM 244 MM 1 1 3/8" (35MM) DIA. HOLE 5 5/8 143 MM 41/4 08 MM UNIT POWER WIRE 5 5/8 1 3/8" (35MM) DIA. HOLE 43 MM (TC MODELS) 1945MM 2" ELECTRICAL CONNECTION 53 1/4" (SINGLE POINT POWER 1353 MM WHEN HEAT INSTALLED) 1/2 NPTGAS CONNECTION (80 mbh, 120 mbh) 3/4 NPT GAS CONNECTION (150 mbh, 200 mbh, 250 mbh) (YC MODELS) CONTROL AND COMPRESSOR ACCESS PANEL Figure 22. Cooling and gas/electric - 71/2-10 tons standard efficiency - downflow airflow supply/return through the base utilities Note: All dimensions are in inches/millimeters. 3 5/8' 92 M4 9 71yl I� 'I`251 'I 4441 MM MMyI� 444/144 4' 102 MM \\ RETURN SUPPLY 32 I/B' 1� 33' 8l6_MIA 838 MM TXROUGH THE BASE CONDENSATE 4 1/.. 04MM 27 MA 70l5/8 40 3/4' 1035 MM THROU2H THE 'BM I27 49 BASE ELECTRICAL 5 71a 1` 10 7/e' 276 MM 1 71 MM 16 1/2' 3 3/4 1165 MM 170 RT-PRCO23-EN 0 caws" Dimensional Data Figure 23. Cooling and gas/electric - 71/2-10 tons standard efficiency - horizontal airflow supply and return Note: All dimensions are in inches/millimeters. 4 1/4" 108 MP 3 7/8" �98 MM 9 3/8" 238 MM Return 32 1/4" 63MM 832MM supply 425 19 1 /4" .23 7/8" 489 MM 606 MM 3/4-14 NPT DIA. HOLE CONDENSATE DRAIN 27 5/8" 701 MM 120 MM Figure 24. Cooling and gas/electric - 6-10 tons standard efficiency - unit clearance and roof opening Note: All dimensions are in inches/millimeters. CLEARANCE CLEARANCE 36" (914 MM) HORIZONTAL FLOW - 18" (457 MM) DOWNFLOW 36" (914 MM) TYPICAL ROOF OPENING / CLEARANCE FROM TOP OF UNIT 72" \ \ 88 46" M 46 \ (2251 MM) (1168 MM) (1168 MM) 53 1/4 (1352 MM) CLEARANCE 48" (1219 MM) \� CLEARANCE 36" (914 MM) RT-PRCO23-EN 171 A TAWE Dimensional Data Figure 25. Cooling and gas/electric - 71/2-10 tons standard efficiency - roof curb Note: All dimensions are in inches/millimeters. 3(0. 46 3/8 G��PRP 1178 MM) 1- IS (A70 MM) (e73 MM) czs'M\M) �" c1166s5MM> 18. r r91y %i47o MA) 80 1/2• 4`S� Mi17� (3s1GMM) (v�� `a" (2045 MM) 83 7/8• J 5MM) (2130 MM) P. Q� t 1- (25MM) Q (44 MM) SVQ 4 3/8' (873MM q Fq�9 8 1/2' �/�, (2146 M) (A9 7/MM) F "1& MM) rl (51 FI) 50 81280 (512 MM) Figure 26. Cooling and gas/electric - 71/2-10 tons standard efficiency downflow -duct connections field fabricated Note: All dimensions are in inches/millimeters. 17 3/4" 451 MM 17 3/4" 451 MM y 33 3/4" / 8-� M I i 33 3/4" 857 MM ALL FLANGES 1 1/4" (31 MM) 172 RT-PRCO23-EN 0 caws" Figure 27. Cooling and gas/electric - 71/2-10 tons standard efficiency - power exhaust Note: All dimensions are in inches/millimeters. Dimensional Data Figure 28. Cooling and gas/electric models - 71/2-10 tons standard efficiency - swing diameter for hinged door(s) option Note: All dimensions are in inches/millimeters. r ] 01 3CONOMIZER HOOD - - - -' n G32 MM 2138" 543 MM pypliceblem v_C moaeis Dory 3458" 8]9 MM Figure 29. Cooling and gas/electric - 71/2-10 tons standard efficiency - economizer, manual or motorized fresh air damper Note: All dimensions are in inches/millimeters. HOOD 3AROMETRIC RI Figure 30. Gas/electric - 71/2-10 tons standard efficiency - height of gas pipe required from inside base of unit to gas shut off assembly (factory provided) - Y_C models only Note: All dimensions are in inches/millimeters. •_j RT-PRCO23-EN 173 0 TRANE' Weights Table 143. Maximum unit & corner weights (Ibs) and center of gravity dimensions (in.) Maximum Model Unit Weights(a) Corner Weights(b) Center of Gravity (in.) Tons Model No. Shipping Net A B C D Length Width 3 TSC036E1,3,4,W 555 480 157 122 95 107 31 19 3 YSC036E1,3,4,W 607 532 165 137 95 134 31 19 3 WSC036E1,3,4,W 589 514 177 107 113 117 29 20 4 TSC048E1,3,4,W 586 511 167 129 101 114 31 19 4 YSC048El,3,4,W 638 563 175 145 101 142 31 19 4 WSC048E1,3,4,W 600 525 181 109 115 119 29 20 5 TSC060E1,3,4,W 636 561 183 142 111 125 31 19 5 YSC060E1,3,4,W 688 613 190 158 110 155 31 19 5 WSC060E1,3,4,W 825 682 228 177 114 163 38 24 6 TSC072E 898 755 295 136 209 115 40 23 6 YSC072E 936 793 304 146 219 124 41 23 71/2 TSC092E 1009 866 358 147 252 109 41 22 71/2 YSC092E 1059 916 370 160 265 121 41 22 81/2 TSC102E 1048 905 359 161 265 120 42 23 81/2 YSC102E 1096 953 371 173 277 132 42 23 10 TSC120E 1111 968 388 171 267 142 40 23 10 YSC120E 1173 1030 403 187 283 157 41 23 (a) Weights are approximate. (b) Corner weights are given for information only. CENTER OF GRAVITY I -LENGTH R CENTR of GRAVITY WIDTH D C CENTER OF GRAVITY Table 144. Maximum unit & corner weights (Ibs) and center of gravity dimensions (in.) Unit Maximum Model Weights(a) Corner Weights(b) Center of Gravity (in.) Tons Model No. Shipping Net A B C D Length Width 3 THC036E1,3,4 566 472 109 85 186 92 40 26 YHC036E1,3,4 637 544 127 103 204 110 39 26 4 THC048E1,3,4 798 653 155 127 248 123 40 25 YHC048E1,3,4 869 725 173 145 266 141 40 25 5 THC060E1,3,4 823 676 204 74 327 71 41 26 YHC060E1,3,4 894 748 222 92 345 89 41 26 (a) Weights are approximate. (b) Corner weights are given for information only. 174 RT-PRCO23-EN TRANE Weights Table 145. Factory installed options (fiops)/accessory net weights (lbs)(e)•(b) Accessory T/YHC Net Weight 3 Tons T/YHC Net Weight 4-5 Tons T/YSC Net Weight 6-10 Tons WSC***E Net Weight 3-4 Tons 5 Tons 460 V IDM Transformer() 29 29 — 29 29 Barometric Relief 7 10 10 7 10 Belt Drive Option 38 — — 38 — Coil Guards 12 20 20 12 20 Economizer 26 36 36 26 36 Electric Heaters(d) 15 30 15 15 30 Hinged Doors 10 12 12 10 12 Manual Outside Air Damper 16 26 26 16 26 Motorized Outside Air Damper 20 30 30 20 30 Novar Control 8 5 8 5 5 Oversized Motor — 8 8 5 8 Powered Convenience Outlet 38 38 38 38 38 Powered Exhaust — — 80 — — Roof Curb 70 115 115 70 115 Smoke Detector, Supply 5 5 5 5 5 Smoke Detector, Return 7 7 7 7 7 Stainless Steel Heat Exchanger(e) 4 — 6 — — Through the Base Electrical 8 13 13 8 13 Through the Base Gas 5 — 5 — — Unit Mounted Circuit Breaker 5 5 5 5 5 Unit Mounted Disconnect 5 5 5 5 5 (a) Weights for options not listed are <5 lbs. (b) Net weight should be added to unit weight when ordering factory -installed accessories. (c) Apply weight with all 460V units with the Standard Direct Drive Motor. (d) Applicable to Cooling and Heat Pump units only. (e) Applicable to Gas/Electric units only. RT-PRCO23-EN 175 0 T/L411/E Mechanical Specifications General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to UL 1995/CAN/CSA No. 236-M90 for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather -resistant baked enamel finish. Unit's surface shall be tested 1000 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allowfor all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and airtight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil -faced, fire -retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil -faced, closed -cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of thecurb otherthan the raised 1 1/8 inch high downflow supply/return openingsto provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Compressors All units shall have direct -drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. All standard and high efficiency units shall have direct -drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Crankcase heaters shall be included on 6-10 ton standard efficiency units. Controls Unit shall be completely factory -wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24 volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti -short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor pressure lugs for power wiring. Units shall have single point power entry as standard. Evaporator and Condenser Coils Internally finned, 5/16" coppertubes mechanically bonded to a configured aluminum platefin shall be standard. Coils shall be leaktested at the factory to ensure the pressure integrity. The evaporator 176 RT-PRCO23-EN 0 laws" Mechanical Specifications coil and condenser coil shall be leak tested to 575 psig and pressure tested to 450 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A removable, reversible, double -sloped condensate drain pan with through the base condensate drain is standard. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 7 and MERV 13 filters shall also be available. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition Afterthree unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field -installed kit) and also complywith the California requirement for low NOx emissions (Gas/Electric Only). High Pressure Control All units include High Pressure Cutout as standard. Indoor Fan 3-5 ton units (standard efficiency 3-phase or high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3-5 ton units (1-phase or high efficiency 3-phase) have multispeed, direct drive motors. All 6-10 ton units shall have belt drive motors with an adjustable idler -arm assembly for quick -adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All indoorfan motors meetthe U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct -drive, statically and dynamically balanced, draw -through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory -installed as standard. An area shall be provided for replacement suction line driers. Unit Top The top covershall be one piece construction orwhere seams exist, it shall be double -hemmed and gasket -sealed. The ribbed top adds extra strength and prevents water from pooling on unit top. Factory Installed Options Black Epoxy Pre -Coated Coils The black epoxy coils have a thermoset vinyl coating that is bonded to the aluminum fin stock prior to the fin -stamping process. The pre -coated coils are an economical option for protection in mildly corrosive environments. CompleteCoatT'" Coils The cathodic epoxy type electrodisposition coating is formulated for high edge build to plate fin and tube heat exchangers. The coating is selected to provide excellent resistance and durability to corrosive effects of alkalies, acids, alcohols, petroleum, seawater, salt air and corrosive environments. RT-PRCO23-EN 177 0 7NME' Mechanical Specifications The option shall be equipped with crankcase heater(s), low pressure switch(es), FrostatTM, and a thermostatic expansion valve(s) (TXV) as standard. Heat Exchanger The compact cabinet features a tubular heat exchanger in low, medium and high heat capacities. The heat exchanger is fabricated using stainless steel burners and corrosion -resistant aluminized steel tubes as standard on all models. It has an induced draft blowerto pull the gas mixturethrough the burner tubes. The heater has a direct spark ignition system which doubles as a safety device to prove the flame. Gas/Electric Precedent models exceed all California seasonal efficiency requirements. They also perform better than required to meet the California NOx emission requirements. Hinged Access Doors Sheet metal hinges are available on the Filter/Evaporator, Supply Fan/Heat, and the Compressor/ Control Access Doors. Novar Return Air Zone Sensor This option, when used in conjunction with Novar Controls, will contain a factory provided and wired zone temperature sensor located in the return air stream. Novar Unit Controls Optional Novar rooftop unit controls shall be installed and tested. The Novar electronic thermostat module will interface to the unit microprocessor and will control the unit to the desired stage of cooling or heating. Powered or Unpowered Convenience Outlet This is a GFCI, 120V/15amp, 2 plug, convenience outlet, either powered or unpowered. When the convenience outlet is powered, a service receptacle disconnect will be available. The convenience outlet is powered from the line side of the disconnect or circuit breaker, and therefore will not be affected by the position of the disconnect or circuit breaker. This option can only be ordered when the Through the Base Electrical with either the Disconnect Switch or Circuit Breaker option is ordered. Stainless Steel Heat Exchanger The optional stainless steel heat exchanger is constructed of 409 stainless steel. It is resistant to corrosion and oxidation and easy to clean. The high strength to weight ratio allows for high ventilation rates with gas units. It is an excellent option to compliment the dehumidification option as a high outside air ventilation unit. With this option, a 10-year stainless steel heat exchanger warranty is standard. Supply and/or Return Air Smoke Detector With this option, if smoke is detected, all unit operation will be shut down. Reset will be manual atthe unit. Return AirSmoke Detectors require minimum allowable airflowwhen used with certain models. See the Installation, Operation, and Maintenance (IOM) manual for the models affected and the minimum allowable airflow required. Thermal Expansion Valve Thermal Expansion Valve is standard for all models. Through the Base Electrical Access An electrical service entrance shall be provided allowing electrical accessfor both control and main power connections inside the curb and through the base of the unit. Option will allow for field installation of liquid -tight conduit and an external field -installed disconnect switch. 178 RT-PRCO23-EN 0 laws" Mechanical Specifications Through the Base Electrical with Circuit Breaker This option is a thermal magnetic, molded case, HACR Circuit Breaker with provisions forth rough the base electricaIcon nections. The circuit breaker will be installed in a watertight enclosure in the unit with access through a swinging door. Wiring will be provided from the switch to the unit high voltage terminal block. The circuit breakerwill provide overcurrent protection, be sized per NEC and UL guidelines, and be agency recognized by UL/CSA. Through the Base Electrical with Disconnect Switch This 3-pole, molded case, disconnect switch with provisions for through the base electrical connections are available. The disconnect switch will be installed in the unit in a watertight enclosure with access through a swinging door. Wiring will be provided from the switch to the unit high voltage terminal block. The switch will be UL/CSA agency recognized. Note: The disconnect switch will be sized per NEC and UL guidelines but will not be used in place of unit overcurrent protection. Through the Base Gas Piping The unit shall include a standard through the base gas provision. This option shall have all piping necessary including, black steel, manual gas shut-off valve, elbows, and union. The manual shut- off valve shall include 1/8" NPT pressuretap. This assemblywill require minorfield laborto install (Gas/Electric Only). Two -Inch Filters Two-inch MERV 7 and MERV 13 media filters shall be available on all models. Factory or Field Installed Options Clogged Filter/Fan Failure Switch A dedicated differential pressure switch is available to achieve active fan failure indication and/or clogged filter indication. These indications will be registered with either a zone sensor with status indication lights or an Integrated ComfortT"' System. This option is available for microprocessor controlled units. Differential Pressure Switches These sensors allow individual fan failure and dirty filter indication for microprocessor controlled units. The fan failure switch will disable all unit functions and "flash" the Service LED on the zone sensor. The dirty filter switch will lightthe Service LED on the zone sensor and will allow continued unit operation. Discharge Air Sensing This option provides true discharge air sensing in heating models. This sensor is a status indicator readable through TracerT°° or Tracker T"^. This option is available for microprocessor controlled units. Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment 'off" cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. RT-PRCO23-EN 179 0 7NME' Mechanical Specifications Electric Heaters Electric heat modules shall be available for installation within basic unit. Electric heater elements shall be constructed of heavy-duty nickel chromium elements internally delta connected for 240 volt, wye connected for 480 and 600 V. Staging shall be achieved through ReliaTelT". Each heater package shall have automatically reset high limit control operating through heating element contactors. All heaters shall be individually fused from the factory, where required, and shall meet all NEC and CEC requirements when properly installed. Power assemblies shall provide single - point connection. Electric heat modules shall be UL listed or CSA certified. Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications (cooling only). LonTalk® Communication Interface This option shall be provided to allowthe unitto communicate as a TracerT' LCI-R device or directly with generic LonTalk Network Building Automation System Controls. Reference or Comparative Enthalpy Reference Enthalpy is used to measure and communicate outdoor humidity. The unit receives and uses this information to provide improved comfort cooling while using the economizer. Comparative Enthalpy measures and communicates humidity for both outdoor and return air conditions, and return airtemperature. The unit receives and uses this information to maximize use of economizer cooling, and to provide maximum occupant comfort control. Reference or Comparative Enthalpy option shall be available when a factory or field installed Downflow Economizer is ordered. This option is available on all downflow models. Tool -less Hail Guards Tool -less, hail protection quality coil guards are available for condenser coil protection. Trane Communication Interface This option shall be provided to interface ReliaTeIT"^ controlled units with the Trane Integrated ComfortT"^ systems. Field Installed Options CO2 Sensing The CO2 sensor shall have the ability to monitor space occupancy levels within the building by measuring the parts per million of CO2 (Carbon Dioxide) in the air. As the CO2 levels increase, the outside air damper modulates to meet the CO2 space ventilation requirements. Dual Thermistor Remote Zone Sensor This sensor will allow the customer to reduce the total number of remote sensors to obtain space temperature averaging. This sensor should be utilized with ReliaTel controls. High Static Drive The high static drive option shall allowthe standard motorto operate with improved external static capabilities. Manual Outside Air Damper This rain hood and screen shall provide up to 50 percent outside air. 180 RT-PRCO23-EN 0 laws" Mechanical Specifications Motorized Outside Air Damper Manually set outdoor air dampers shall provide up to 50 percent outside air. Once set, outdoor air dampers shall open to set position when indoorfan starts. The damper shall close to the full closed position when indoor fan shuts down. Programmable Night Setback Auto or manual changeover with seven-day programming. Keyboard selection of Heat, Cool, Fan, Auto, or On. All programmable sensors have System On, Heat, Cool, Service LED/indicators as standard. Night Setback Sensors have one (1) Occupied, one (1) Un-occupied, and one (1) Override program per day. Remote Potentiometer The minimum position setting of the economizer shall be adjusted with this accessory. Roof Curb The roof curb shall be designed to mate with the unit's downflow supply and return and provide support and a watertight installation when installed properly. The roof curb design shall allow field -fabricated rectangular supply/return ductworkto be connected directlyto the curb. Curb shall be shipped knocked down for field assembly and shall include wood nailer strips. Thermostat Two stage heating and cooling operation or one stage heating and cooling shall be available in either manual or automatic changeover. Automatic programmable electronic with night set back shall also be available. Ventilation Override Accessory With the Ventilation Override Accessory installed, the unit can be set to transition up to 3 different pre-programmed sequences for Smoke Purge, Pressurization, and Exhaust. The transition occurs when a binary input on the RTOM is closed (shorted). This would typically be a hard wired relay output from a smoke detector or fire control panel. The ventilation override accessory shall be available as field installed. Zone Sensor This control shall be provided to interface with the Micro equipped units and shall be available in either manual, automatic programmable with night setback, with system malfunction lights, or remote sensor options. RT-PRCO23-EN 181 ENERGY STAR TRINE° Literature Order Number RT-PRCO23-EN Date January 2009 Supersedes RT-PRCO23EN October 2008 www.trane.com c & us For more information, contact your local Trane Trane has a policy of continuous product and product data improvement and reserves the right to office or e-mail us at comfort@trane.com change design and specifications without notice.