Compaction Report 07_15_2022_WardakSOIL FIELD DENSITY REPORT
AAR TESTING AND INSPECTION, INC.
7126 180th Ave NE, Suite C101
Redmond, WA 98052
425-881-5812
CLIENT INFORMATION PROJECT INFORMATION I OTHER INFO.
Contact Todd O'Dell Project No. 22-448 Time 12:29 PM
Company Vadell Homes LLC Project Name Wardak Temperature (OF) 80
Address 16027 Sunset Rd Address 541 12th Ave N
City Bothell City Edmonds
Contractor Permit No. NA
Inspection Date
07/15/2022
Report Number
SAS071522AS
MATERIAL DATA TEST DEVICE STANDARD COUNT TEST METHOD
Material 5/8" minus crushed Equipment No. 483 Density Count 2468 Field Test Method ASTM D6938
aggregate
Layer Thickness 12 Make Instrotek Moisture Count 729 Lab Test Method ASTM D1557
Source Import Model 3500
Compaction Method Vibratory compactor Serial No. 4549
TEST SITE / TEST LOCATIONS
Test No.
Location / Elevation
Depth
Field Dry
Field Wet
Field
Lab
Lab
Lab
Compaction
Required
Density
Density
Moisture
Reference
Maximum
Moisture
(%)
Compaction
Content
Number
Density
Content
(%)
(%)
(%)
1
Right of way utility backfill
12"
129.8
139.0
7.1
22704
136.2
8.0
95
95
REMARKS / SPECIFICATIONS
Testing in the right way indicated compaction of at least 95% per proctor.
CONFORMING
SIGNATURE
Inspectors Name Report Complete Date Reviewed By Reviewed Date
Stu Swenson 07/15/2022 Teajalam (TI) Gounden
1f98438fc90ec344-1657913365593