APPROVED BLD-RESUB 1-Floor Plans+9.1.2022_1.13.09_PM+3086339PERMITTING & DEVELOPMENT
BUILDING DIVISION
121 5th Avenue N
P: 425.771.0220
www.edmondswa.gov
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
r- - - - - - - - - - - - - - - - - - - - -
1 WHERE
NS OR ALTERATIONS REQUIRE A
ERMIT TO BE ISSUED INTERCONNECTED SMOKE
ALARDWELLING DETECTORS AND CO THROUGHOUT E ING ARE REQUIRED. REFER TO 2018 IRC
LR314 AND R315 FOR MORE INFORMATION.
----------------------
APPROVAL STAMP PAGE
RvrenS
PLEASE KEEP WITH THE PLANS
-------------------
SEPARATE PLUMBING PERMIT ,
REQUIRED FOR THIS PROJECT.
L- — - — - — - — - — - — - — - — - — -
City Of Edmonds
Building Department
AFH-REMODEL
------------------------------------------------
Address 21011 88TH PL W
Owner �--------------------------GHINEA------------
Approved Date
Building Official
Permit Number
09/13/2022
/ce'lpl t 151 oor�Mal
BLD2022-0981
Approved by Fire
09/13/2022 AFM /CFGtterer
RESUB
Sep 01 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
NOTE: This Stamp page must remain with the city approved plans at all times. Failure to have this
Stamp page with the City approved plans could result in delay of the inspections including the FINAL
inspection. If lost please contact the city as soon as possible to find a solution. Thank You.
21011 88th PI.W Proposed plan
Edmonds, WA, 98026
Fire Extinguisher 2A:1013:C
Scale 1/4"=1'
First floor 1868 sqf
O Thermostat
Hardwired and Interconnected
OSmoke Detector/Carbon monoxide
with battery backup
Grab bars in bathrooms will comply
with section R330.8 per WAC 51-51-330
Ramp and landing
made of trek with
spacing in between
Non structural, non resistance partition
wall, made of drywall over wood frame
CD
using 2x4x8's a
Walls don't need reinforcement ♦ 15' 6" ►
down below
♦ 15' 2"EN
►
Bedroom A
15.2'x10.1'
NS1
3
8' ceiling height
o
_...............................................
ww
00
�5'4"►
0 ; •
o
M
♦ ♦ 00u<0.3 Bat+hr orrt:
zo I
o ♦ Bathroom EN v 4 5' 4" ►
5, 50cfm
c\ o
♦ o
o 50cfm Fan
4 3' 0„ ► \ ►
Not a load s o
bearing wall
M
co
,It
zo
N < Clot
I
-43' 8"►
15- 0" ►
-4;i•14"I-
1 18' 8" ►
Deck
0
�6' 1 1/16"►
6' 0" ►
Exit Door 36"
�30►
Kitchen
8' ceiling height
co
w
0
i7
v
W n
10' 10" ► &` 1 6' 0" ►
♦ Bedroom B O Closet
3' 8„ ► 130 sqf . D
NS1 Entry
8" ceiling height
1' 4"
�13'0" �1' "►
24" sill height
Egress Window
Existing Window
1 OF 6
14' 0"►
Dining Roorti" --
8' ceilin-§• height
121' 0"►
10' 4 15/16" ►
Furnace
0
♦ �90►
7
/ O
6' �� ►�� � ' 7 5/8� 0 O
0
♦ i
Bathroom o0
Closet
i 50cfm Fan
Laundry zo
iv
8ft ceiling height
I3 0 ♦ 18' 8"►
IT 0"►
4`2 10"►
:7' 16- 4" 1 CD 0
.44' 6 15/16"►
co
S
Bathroom
N ; 8ft ceiling heigh�
♦ V 6' 0" ► 50cfm Fan
Bedroom CK
12"X11"
NS1 24" sill hei ht
8'ceiling eQh1 j. 0„ ► Egress Window
\' Existing Window
• 12' 8" ►
tgress vvinaow
Existing Window
418' 11 1/16"►
8' ceiling height
HW
1 27- 0" ►
Ramp
00
N
W
1 4' 0'1►
0
v
00
See plan B for ramp
0
Landing
Existing Asphalt
Exit toward driveway
(street)
RESUB
Sep 01 2022
CITY' -OF EDMONDS
EVELOPMENT SERVICES
21011 88th PI.W
Edmonds, WA, 98026
Scale 1W'=1'
First floor 1868 scif
Non structural, non resistance
partition wall, made of drywall
over wood frame using 2x48's
Walls don't need reinforcement
down below
Not 10A
beaunC ..,all
Proposed plan
Clouding shows
were the remodeling is taking
place
Fire Extinguisher 2A:10B:C
O Thermostat
0 Hardwired and Interconnected
Smoke DetectorlCarbon monoxide
with battery backup
Grab bars in bathrooms per checklist
Ramp and landing
made of composite with spacing in between
Minimum prescriptive value of the new window will be .30 as per 2018 WSEC.
2OF6
Exit toward driveway
RESUB
Sep 01 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
�18'8"►
Existing floor plan
21011 88th PI W
Edmonds, Wa, 98026
Scale 1/4"=1'
George Ghinea
2062354070
I LJ
Living Room
3' 8" ►
i
page 2 of 6 3 OF 6
Deck
0 0
Kitchen
16' 0"►
0
800
M O
vI v
0
0
=1� n�] �J
14' 0"►
Walkway
Dining room
1 21' 0" ►
CD
� o00 ®®o00
[jBat4hroo.s co
l 1
r r
0 Laundry
zo
♦ Office
co
N 00
� 10' 11"►♦
�3'2"►
13- 8„ ►
18' 11 1 / 16" ►
Family room
14' 0" ►
Garages
Existing asphalt
RESUB
Sep 01 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Q S/Co
Smoke de
monoxide
backup
4 OF
RESUB
Sep 01 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
1' 0"►
5OF6
21011 88th PI W
Edmonds, WA, 98026 _-_-_-_-_-_-_
FROM COMMENT RESPONSE LETTER RECIEVED ON SEPTEMBER 1 2022:1
Scale 1/4=1 L_-_-_-_-_-_-_-_-_
George Ghinea Ramp will comply to WAC51-51-0330SectionR331-8
-All wood must be pressure -treated or naturally resistant to decay. Treat cuts, holes, and
2062354070 notches with end -cut solution.
• Fasteners, hangers, nails, etc., must be stainless steel, hot -dipped galvanized, or as
specifically required for the specified wood preservative used. The coating weights for zinc
coated fasteners to be in accordance with ASTM A 153.
V Materials
Cement
Post pier connectors
4x4 beams
2x6 joists
joist span 16"
lag bolts, joist hangers, Simpson ties, hurricane tie, deck screws,
composite decking
Ramp 1:12
27' 0" ►
SUB
)1 2022
-EDMONDS
DEVELOPMENTSERVICES
DEPARTMENT
Grab bars bathrooms
4" rr
Dispensers within reach
range (see table)
�16" - 18"
60" min. clear
BACK WALL
39" - 41" Grab bars 1-1/4" to 1-1/2"
in diameter and 1-1/2"
54 min. between bar and wall
12" max.
- — - — - — - — - — - — - — - — -
FROM COMMENT RESPONSE LETTER RECIEVED ON SEPTEMBER 1 2022:
- — - — - — - — - — - — - — - — -
cM Itt
For all bathrooms serving clients:
E fh M
QO M
Grab bars complying with IRC R330.8
24" - 42"
The water closet will be set no closer than
SIDE WALL 15 inches from the side wall to the centerline
of the water closet. UPC 2018 section 402.5
Clearance space of 21" in front of the toilet in
accordance with 2018 UPC 402.5 as
amended by the Washington State
Administrative Code (WAC).
60F6