DNS-RESPONSE 1 BLD+9.1.2022_1.14.00_PM+3086345Cover letter for remodel at 21011 88th PI. W Edmonds, Wa, 98026 1. Second floor is to remain as is. See attached plans 2. Plan sheets were number and labeled. 3. Fixtures existing and proposed: -6 toilets, 10 sinks, 2 bathtubs, 2 showers, 1 washing machine. Total of 21 fixtures. 4. The scope of work is: - to make 2 bedrooms and 2 half bathrooms in the existing living room, - build a new bathroom in the existing laundry room -open bathroom and closet for an existing office room Existing opening of one exterior wall to be filled in with drywall over wood frame, insulation, siding. To build the interior walls: doing non-structural, non-resistance partition wall, made of drywall over wood frame using 2x4x8's. Walls don't need reinforcement down below. 36" doors will be added to the new rooms and to the bathrooms. 32" door added to the laundry room. Smoke/CO2 detectors will be added, wired and interconnected. New window added in one bathroom. Existing windows remain as is. 5. Smoke/CO2 detectors will be added, see plan. Units will be wired and interconnected to a separate breaker at the electric panel in the garage. It will comply with section R330.5 per WAC 51-51-0330 6. Minimum prescriptive value of the new window will be .30 as per 2018 WSEC. 7. Grab bars in bathrooms and showers will comply with section R330.8 per WAC 51-51-0330 8. Ramp will comply to WAC 51-51-0330 Section R331-8 -All wood must be pressure -treated or naturally resistant to decay. Treat cuts, holes, and notches with end -cut solution. • Fasteners, hangers, nails, etc., must be stainless steel, hot -dipped galvanized, or as specifically required for the specified wood preservative used. The coating weights for zinc - coated fasteners to be in accordance with ASTM A 153. Materials Cement Post pier connectors 4x4 beams 2x6 joists joist span 16" lag bolts, joist hangers, Simpson ties, hurricane tie, deck screws, composite decking Joist Composite Decking Joist Spacii Soo span table tooting schedt Pc 04 min up to 8'•a' hei Non-( postlbi Continuou, Be 94" MAyiMlIM TYPICAL CONSTRUCTION CONNECTORS RafterlTruss Clips Post -Beam Connectors .4 p 0 • G e' Post -Pier Connectors Holdowns Post Cap (PCXX) 4x4 Pressure Treated Post Post Base (PBXX( 0 p - Continuous Footing t 16" Typical Crawlspace Post & Beam 24" a Entry Porch/Deck Post & Beam (X) created Post :X) Sizing of Structural Elements Maximum Deck Joist Span a.c Joist Joist Spacing b inches Joist Back Span Size 12 1 16 1 24 4 6 8 10 1 12 1 14 1 16 18 Allowable Joist Span Maximum Cantilever (feet inches) Adjacent Joist Span feet 2x6 7-11 7-1 5-9 1-0 1-6 NP NP NP NP NP NP 2x8 10-5 9-5 7-8 1-0 1-6 2-0 2-1 NP NP NP NP 2x 10 13-3 11-6 9-5 1-0 1-6 2-0 2-6 2-8 NP NP N P 2x12 15-5 13-4 10-11 1-0 1-6 2-0 2-6 3-0 3-3 NP NP a. Includes Incising Factor. b. When using composite decking, refer to manufacturer's installation instructions for maximum spacing of joists. c. Spans based on Doug Fir -Larch, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. Minimum Beam Size Deck Joist Span feet 6 8 10 12 1 14 16 18 Beam Size c,d,e Maximum Beam Span a,b,d (feet -inches) 4x6 5-2 4-6 4-0 3-5 3-1 2-10 2-7 4x8 6-11 6-0 5-3 4-7 4-1 3-8 3-5 4x10 8-5 7-4 6-6 5-10 5-2 4-9 4-5 4x12 9-10 8-6 7-7 6-11 6-4 5-9 5-4 6x6 6-6 8-8 5-7 7-6 5-0 4-7 4-2 3-9 3-5 6x8 6-8 6-1 5-6 5-0 4-7 6x10 10-7 9-2 8-2 7-6 6-11 6-4 5-10 6x12 12-4 1 10-8 9-7 8-9 8-1 1 7-7 7-1 a. Spans based on Doug Fir -Larch, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. b. If 2x built up beams to make 4x or 6x beams, they shall be fastened with two rows of 10d (3-inch X 0.128-inch) nails minimum at 16 inches on center along each edge (507.5) c. Beam depth shall be equal to or greater than the depth of intersecting joist for a flush beam connection. d. Beam cantilevers are limited to the adjacent beam's span divided by 4. e. Includes incising factor. Maximum Deck Post Height Tributa Area e Post 20 40 60 80 1 100 120 140 160 Size c,d Maximum Deck Post Height a feet -inches 44 10-0 10-0 8-7 7-0 5-8 4-1 N P N P 46 14-0 13-10 11-1 9-5 8-2 7-3 6-4 5-4 6x6 14-0 14-0 14-0 14-0 14-0 13-3 10-9 6-11 8x8 14-0 14-0 14-0 14-0 14-0 14-0 14-0 14-0 a. Measured from the underside of the beam to top of footing. b. Based on Doug Fir, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. c. Notched deck posts shall be sized to accommodate beam size. d. Includes incising factor. e. Area, in square feet, of deck surface supported by post and footing. Footing Size a b Side of Square Diameter of a Thickness Tributary Area Footing (inches) Round Footing (inches) inches 5 7 8 6 20 12 14 6 40 18 20 6 60 21 24 28 8 80 25 9 100 28 31 11 120 30 34 12 140 33 37 13 160 35 40 15 a. Footing dimensions shall allow complete bearing of the post. b. Area, in square feet, of deck surface supported by post and footings. 12" min. frost depth In allowable Solis —Manufactured post connector Typical P.T. post 12" II' Grade Thickness per Table 1/2" diameterT- Note: Posts must be W2a Si_7 r i centered on or in footin peethr through -bolts In both 4" gravel Min. 12" of 9 Table directions embedment Note: not screws LEDGER ATTACHMENT FROM RAMP TO DECK Existing 2x BAND JOIST OR ENGINEERING RIM BOARD Lag screw or bolt 2" min. 5" max. -�-- �2" min. Minimum edge distance for specialized screws. See manufacturer's technical bulletin. Connections and Fasteners Ledger RAMP JOIST .AG SCREWS OR BOLTS JOIST HANGER Stagger fasteners in 2 rows 5 1/2" min. for 2x8 6 1/2" min. for 2x10 7 1/2" min. for 2x12 3/4" min. Distance can be reduced to 4 1/2" if lag screws are used or if bolt spacing is reduced to that of lag screws to attach 2x8 ledgers to 2x8 band joists (All fasteners, nails, bolts, screws, and connectors must be corrosion resistant.) Manufactured Connectors Follow manufacturer's instructions Post to Footing Post base is required Post to Beam Connector is required Joist to Beam or Girder (3) 8d — Toe nailed Blocking or Bridging to Joist (2) 10d — Toe nailed at each end Wooden Deck Boards (2) 8d threaded nails OR (2) No. 8 screws Composite Decking Follow manufacturer's instructions Sample Section/Elevation View T E m Intermediate rails spa ed th t a E 4" 5 e an of astrug t, Lag Molts (tYp) O is Joist Hanger Positive Connection required at all (see attached details) posts and beams (see attached details) Ledger with iag bolts (provide bolt sizelspacing Ledger Flashing required ** All wood exposed to weather shall be pressure treated or naturally resistant to decay ** Minimum design loads 70 p.s.f (10 live 160 dead) ** Provide size, spacing, wood species and grade for all framing members including joists, beams, posts, ledgers, decking and guardrails nI Post -to -concrete pier connection required see attached details) to min ** Footings shall be placed on firm, — undisturbed, bearing soil (2000 p.s.f. min.) 2" min. Handrail 12' min. C Edge Protection a Ramp Grab bars bathrooms 4" max. Dispensers within reach range (see table) C E SIN �16" - 18" 60" min. clear BACK WALL 39" - 41" Grab bars 1-1/4" to 1-1/2" in diameter and 1-1/2" 54 min. Mir between bar and wall 12" max. M � _E M M � M 24" - 42" SIDE WALL