22.012 ~ Lang Site Built Truss ~ 05-03-23May 3, 2023 #22.012 Sara Lang 19637 801h Pl W Edmonds, WA 98026 Subject: Site Built Girder Truss Plan Number: Lang Addition Site: 19637 801h Pl W Edmonds, WA 98026 Mrs. Lang, Phillips Structural Engineering, PLLC (PSE) as requested has reviewed the condition where your General Contractor (Built By Design, Inc.) has provided a roof retrofit for existing conditions that the City of Edmonds is requiring some Engineering documentation on. It is our understanding that the roof had a minor amount of sag in it and Built By Design has retrofitted the areas under consideration with new ceiling joists and a 3 ply truss. Please find attached a partial roof framing plan indicating where the truss was installed and necessary upgrades/retrofits to increase its strength. Trusses shall be attached to one another with TimberLOK TLOK06 screws as indicated in detail 2/SK through the layer of 3/4" plywood on the side where the beam has been added (reference ICC ESR-1078 by OMG, Inc.). A Simpson MSTC66 strap shall be added to the opposite side of the multi- ply truss attached to bottom chord and added 2x4. See attached for additional information. All other aspects of design and conditions on site including construction methods are per the approved structural drawings. If there are any further questions or concerns, please feel free to contact our office. Sincerely, Todd M. Phillips, S.E. Phillips Structural Engineering, PLLC Phillips Structural Engineering, PLLC PO Box108 Milton, WA 98354 u END (FUR WALL AS 4x6 POST W/ RING); PR❑VIDE LCE4 24'x24"x10" UNREINF. OSITIVE ATTACHMENT CONC. PAD BELOW I I RS ARE NOT BEARING ON I Q I SUPPORTS CEILING ONLY) PQ I w I J J a RIDGE > � I a_ I a_ I J_ W U I tl' 0 w �@ (E)RAFTER 24" O.C. °N(E)RAFTER /PED , EA. SIDE @ 24' D.C. M 2x6 CEILING JOIST @ 24' O.C. 2x6 CEILING JOIST @ 24, O.C. �CQ�12,5 I (E)GIRDER TRUSS TO BE REINFORCED (2)2x6 MIN. 3 SK ' a' w LD LD ra m x c� EXISTING MILD PITCHED SCISSOR TRUSSES 2 24' O.C. N O W 2x6 RAFTER @ 24' D.C. W/ COLLAR TIE @ 4' D.C. LOCATION OF DUTCH HIP GIRDER TRUSS (MINOR) (2)13/4"X9/4" LVL VALLEY BEAM SPANS FROM INTERIOR BEAM AT CENTER TO EXTERI❑R WALL (SIMILAR AT OPP❑SITE SIDE) 1,2 SK PARTIAL ROOF FRAMING SCALE: %4" = l'-0" 00 (2) NEW TRUSS PLYS HAVE 2x6 TOP AND BOTTOM CHORDS 00 (1) EXISTING TRUSS HAS 2x6 TOP CHORD AND 2x4 BOTTOM CHORD 00 EXISTING ROOF SHEATHING NOT SHOWN \Ll L_A I LI\1 Li 1\ WALL SITE BUILT GIRDER TRUSS (10) TIMBERL❑K TL❑K06 SCREWS AT TOP CHORD EA. SIDE OF CENTER THRU PLYWOOD TO MULTI -PLY TRUSS @ 12" O.C. (STAGGERED) APPROX. SHEATHING SPLICE 48" FROM CENTER (3) PLY TRUSS SHEATHED W/ 3/4" PLYWOOD NAILED AT 6" O.C. TO ALL MEMBERS (EA, PLY TO HAVE A LAYER OF SHEATHING) (14) TIMBERL❑K TL❑K06 SCREWS AT BOTTOM CHORD EA. SIDE OF CENTER THRU PLYWOOD TO MULTI -PLY TRUSS @ 6" O.C. (STAGGERED) SHEATHING & TRUSS TO TRUSS ATTACHMENT ADD NEW 2x4 OVER (E) BOTTOM LHWRD lOd P@ ❑g E �, TOE NAI (E)2x4 BOTTOM CHORD REMOVE (E) WEB IN TRUSS AS REQ'D MSTC66 CENTERED ON TRUSS ATTACHED TO BOTTOM CHORD OF (E) TRUSS AND NEW 2X4 AS SHOWN W/ (76)0,148"x3/4" NAILS BACK SIDE VIEW GIRDER TRUSS (EXISTING TRUSS MODIFIED) 3 of 3