REVIEWED-RESUB 1-Structural_Plans+7.28.2022PHLLPS 8VRUCVURAL BIGHEERHIS GENERAL NOTES: The Structure has been designed to resist code -required vertical and lateral forces after the construction of all structural elements have been completed. Stability of the structural elements prior to completion is the sole responsibility of the General Contractor. Builder is to verify all dimensions prior to starting work. All changes to structure must be reviewed and approved by Phillips Structural Engineering. All materials, methods, and workmanship shall be in accordance with the International Building Code (IBC) 2018 Edition. The Builder is responsible for using safe work practices and conforming to all safety ordinances. Any construction observation performed by the Structural Engineer is for general conformance with design aspects per IBC 1704.6 and is not intended in any way to review the General Contractor's construction procedures. Structural observation does not waive the responsibility for special inspections per Section 1705. STANDARDS: All methods, materials and workmanship shall conform to the 2018 International Building Code (IBC) as amended and adopted by the local Building Official or applicable jurisdiction. STRUCTURAL DESIGN CRITERIA AND LOADING: ROOF LOADING: • DEAD LOAD = 15PSF (NO TILE WEIGHT INCLUDED) • ROOF LIVE LOAD (Lr) = 20PSF • TYPICAL FLAT ROOF SNOW LOAD (Pf) = 25PSF • SNOW EXPOSURE FACTOR (Ce) = 1.0 • SNOW LOAD IMPORTANCE FACTOR (Is) = 1.0 **TYPICAL ROOF SNOW LOAD SHALL NOT BE LESS THAN 25PSF FLOOR LOADING: • DEAD LOAD = 12PSF (STANDARD WOOD FRAMING WITHOUT HEAVY FINISH) • TYPICAL RESIDENTIAL OCCUPANCY LOVE LOADING (L) = 40PSF • DECK LIVE LOAD (L) = 60PSF (1.5X FOR AREA SERVED) WIND DESIGN DATA: • BASIC DESIGN WIND SPEED (V) = 110 MPH • ALLOWABLE STRESS DESIGN WIND SPEED (Vasd) = 85 MPH • RISK CATEGORY = II • WIND IMPORTANCE FACTOR (Iw) = 1.0 • WIND EXPOSURE = " B" • TOPOGRAPHICAL EFFECT (Kzt) = 1.00 EARTHQUAKE DEIGN DATA: • RISK CATEGORY = II • SEISMIC IMPORTANCE FACTOR (le) = 1.0 • MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS - Ss = 1.30 - S1 = 0.46 • SEISMIC DESIGN CATEGORY (SDC) _ " D" • BASIC SEISMIC FORCE -RESISTING SYSTEM = LIGHT -FRAMED (WOOD) WALLS SHEATHED WITH WOOD STRUCTURAL PANEL RATED FOR SHEAR RESISTANCE • RESPONSE MODIFICATION FACTOR (R) = 6.5 • ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE SOIL INFORMATION: In the absence of a soils report (prepared by a Licensed Geotechnical Engineer) an Allowable Soil Bearing Pressure (ASBP) of 1500psf has been assumed for design. It is the contractor's responsibility to verify that all footings bear on firm/unyielding, undisturbed earth or compacted "Structural Fill" that meets or exceeds the assumed allowable soil bearing pressure. Soils under footings and slabs to be a minimum of 95% compacted per the Modified Proctor Density Test (ASTM D1557). All construction on fill shall be reviewed by a licensed Geotechnical Engineer. FOUNDATIONS: Bottom of exterior footings shall be a minimum of 18" below finished grade for frost protection U.N.O. bearing on undisturbed native soils. Backfill with dry, free draining soils. Backfill next to any retaining walls with a minimum of 12" gravel or free draining soil per typical detailing. Appropriate drainage shall be provided adjacent to the base of exterior foundations draining to daylight per Soils Engineer requirements. CONCRETE: All concrete materials and placement shall conform to the current ACI 318 code. Concrete shall be made with Portland Cement ASTM C-150 Type II or Type I and shall be Ready -Mixed per ASTM C-94. Minimum compressive strength shall be 3000 PSI* at 28 days with a minimum water/cement ratio of 0.45. All concrete shall be air entrained 5 ±1 %. Max aggregate size = %". *Special Inspection not required for concrete compressive strength. 3000 PSI compressive strength has been specified for weathering protection. Structural design of concrete has been based on 2500 PSI compressive strength. PLAN VERACITY: Every attempt has been made to insure the accuracy of these engineered documents, site conditions, product availability, etc. All information listed above must be verified prior to construction and fabrication. Any changes or deficiencies on or to the plan must be transmitted to Phillips Structural Engineering, PLLC for written approval. LICENSE OF ENGINEERING DOCUMENTS: 1. Grant of License: Phillips Structural Engineering, PLLC grants the Licensee a nonexclusive Right of Use for the purpose of constructing a single structure (use) from this engineering package. Future uses of this drawing set are permitted when accompanied by an originally stamped "Site Specific Re -Use Letter" for each additional site and payment has been made to Phillips Structural Engineering, PLLC. 2. Ownership of Engineering Calculations and Drawings: Phillips Structural Engineering, PLLC shall retain "Title 17 USC Rights and Ownership" of the Copyright Law of The United States of America of these Engineering Documents and all subsequent copies of the engineering. The Licensee is not permitted unlimited reuse of these documents without prior consent. 3. Copy and Transfer Restrictions: Unauthorized copying of the Engineering documents is strictly forbidden. The Engineering is permitted to be used by the Licensee only, and may not be transferred to a 3rd party without prior written consent of Phillips Structural Engineering, PLLC. REINFORCING STEEL: All reinforcing steel to be GRADE 60 PER ASTM A-615. Reinforcement lap splices shall be the greater of 32 bar diameters or 18". Lap horizontal steel at all corners and intersections in footings and walls with continuous corner bars. Footing reinforcement shall run continuous thru pad/expanded footings. Minimum concrete cover over reinforcing steel shall be provided as follows: • INTERIOR FACES OF SLAB AND WALL BARS = 1%2 " • EXPOSED TO WEATHER OR EARTH = 1%2" AT #5 AND SMALLER AND 2" AT #6 AND LARGER. • CONCRETE CAST AGAINST SOIL = 3" WOOD FRAMING AND CARPENTRY: General Requirements: Provide minimum nailing per 2018 IBC table 2304.10.1 or as indicated on the drawings. Do not notch or drill structural members, except as permitted by the Engineer. Framing Connectors: Only ICC / IAPMO approved connectors shall be used in framing applications as manufactured by Simpson Strong -Tie or equivalent. Provide maximum size and quantity of fasteners shown in the manufacturer's catalog U.N.O. Fasteners: Bolts shall be per ASTM A-307 with standard cut washers or malleable iron washers. Post -installed anchors require Engineer's approval prior to installation. Contact Phillips Structural Engineering for possible alternatives. Nails shall be common wire nails or equivalent pneumatically drive nails (P-nails), American or Canadian manufacturer only as indicated below. P-nails shall be installed per the manufacturer's guidelines. COMMON WIRE NAIL DIAMETER (INCHES) MINIMUM LENGTH (INCHES) NAIL APPLICATION 8d COMMON 0.131 2 z" SHEATHING 1Od COMMON 0.148 2%" SHEATHING N/A 0.131 3" FRAMING 12d COMMON 0.148 3%4' FRAMING 16d COMMON 0.162 V2" FRAMING Wood Sheathing (Structural): Roof sheathing shall be %2" CDX or 7/6" OSB nailed w/ 8d @ 6" o.c. along panel edges, and 12" o.c. in field. Span index shall be 24/0. Plywood Sub Flooring shall be 3/4" T&G CDX or OSB (glued & nailed). Nailing shall be 1 Od @ 6"o.c. along panel edges, and 12"o.c. in field (U.N.O.) Span index shall be 48/24. Stagger all end laps per typical detailing. All sheathing shall bear the grade trademark of the American Plywood Association (APA). Studs: All studs shall be kiln dried (KD) or surface dried (SD). Each stud shall bear the stamp of the West Coast Lumber Inspection Bureau (WCLIB) or Western Wood Products Association (WWPA) showing grade mark or approved equal. All studs and framing material shall be 2x nominal minimum material and species shall be a minimum of Hem -Fir stud grade meeting the following minimum strength properties: Fb= 675psi, Fv=150psi, E=1,200,000psi. Headers - All headers (HDR) not specified or otherwise noted on the plan with spans <_5-0" are to be 4x8 DF#2 or (2)2xl0 HF#2 with at least one cripple and one king stud at each end. Spans between 5-0" and 8'-0" shall have headers as noted on plan and have at least two cripples and one king stud U.N.O. Spans greater that 8'-0" shall have framing and support per plan. Heavy Timbers: All timbers above sizes listed above including posts and beams shall be Doug -Fir #2 or better (Typically 6x beams and posts). Glu-Laminated Beams (GLB): All GLB shall be in conformance with ANSI Al 90.1, American National Standards for Structural Glue -Laminated Timber. Grade 24F-V4 shall meet or exceed the following minimum structural properties: Fb=2400psi, Fv=240psi, E=1,800,000psi and shall be used at simple spans. Grade 24F-V8 shall be used at continuous and cantilevered spans. As an alternative at continuous/cantilevered spans an equivalent size (width x depth) PSL beam may be substituted (see below). Parallel Strand Lumber (PSL): All PSL shall be in conformance with ASTM D2559 and NER-292. PSL strength requirements shall meet or exceed the following minimum structural properties: Fb=2,900psi, Fv=290psi, E=2,000,000psi. Laminated Veneer Lumber (LVL): All LVL shall be in conformance with ASTM D2559. LVL shall be made of Doug -Fir (DF)and meet or exceed the following minimum structural properties: Fb= 2,600psi, Fv=285psi, E=1,900,000psi. Preservative Treatment (P.T.): All exposed framing including lumber, plywood and deck materials shall be pressure treated with 0.25#/cf pentachlorophenol per AWPA specification P-5 or other approved treatment. All cutting and boring after pressure treatment shall be cared for in accordance with AWPA specification M-4. Exposed framing includes, but is not limited to: 1. Joists, girders and subfloor that is closer than 18" to exposed ground in crawl spaces. 2. Wood framing (including sheathing) that rest on exterior foundation stem walls and is 8" or less from exposed earth. 3. Any other wood product in direct contact with concrete or masonry. Wood Connectors at P.T. Conditions: Metal connectors which are in contact with pressure treated wood shall be protected with one of the following: Simpson "ZMAX" G185 Galvanization, Triple Zinc Coated, hot Dipped Galvanized or other approved method. Pre -Engineered Roof and Floor Trusses: All prefabricated wood roof and floor trusses shall be designed by or under the direct supervision of a licensed Professional Engineer registered in the state where the structure is located. The truss shop drawings shall bear the stamp of that Engineer and shall be fabricated and installed per the latest Truss Plate Institute standards. Where trusses are not provided to complete the roof system, overframing members with positive connections shall be provided as directed by the Truss Engineer. Details on overframing shall be provided in the truss shop drawing package which shall be consistent with the modeling of the trusses. All necessary temporary and permanent bridging, blocking, pre -notched plates, hangers, etc. for the stability of the truss elements under gravity and lateral loads shall be designed, detailed/specified and furnished by the manufacturer. The Truss Manufacturer shall verify all setbacks, dimensions and bearing points prior to fabrication. Deviations from the layout shown on approved engineering plans shall be submitted to PSE for further evaluation. Maximum allowable deflections shall be as follows: Roof Total Load = L/360 or 1" (whichever is less) Roof Snow/Live Load = L/480 or 3/4" (whichever is less) Floor Total Load = L/360 or %" (whichever is less) Floor Live Load = L/480 or %2" (whichever is less) Trusses shall be designed for the spans and conditions shown and be constructed from a minimum of Hem -Fir timber and be furnished and installed in conformance with the manufacturer's published specifications. Additional concentrated loads from mechanical units and misc. equipment shall be accounted for/coordinated with sub -contractors, the Designer of Record and Truss Engineer. Framing has been designed assuming Hem -Fir plates w/ 405psi crushing capacity, truss engineer to confirm compatibility and add bearing enhancers or additional support as required. Where trusses align with shear walls, truss engineer to design and provide a truss that has been designed to transfer lateral wind and seismic forces as shown on the plans. Loading indicated (100plf minimum) shall be designed by the truss engineer to transfer from roof or floor sheathing to shearwall below. Shop drawings including truss engineering shall be submitted to the Engineer of Record for approval prior to submittal to the jurisdiction and fabrication. Should the truss engineering not be submitted to the Engineer of Record for review the builder is assuming responsibility and proceeding at their own risk. Alteration of the truss layout indicated on the plans may require supporting structural and foundation changes, therefore prior approval by the designer and Structural Engineer is required. Trusses shall not be field altered in any way without written approval from the Licensed Truss Engineer of Record. BLD2022-0628 REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT SYMBOL & ABBREVIATIONS LEGEND: (D CXI A. B. AFF C.I.P. CONC. .N. E.O.R. E.W. FDN. F. F. G. T. GWB HDR L. B. W. MFR () N O.C. P.E. P. T. S. W. T. 0. F. T. 0. W. U.N.O. V.I.F. BEAM # CALLOUT (REF. CALCULATIONS) HOLD DOWN CALLOUT (REF. HOLDOWN TABLE) SHEARWALL CALLOUT (REF. SHEARWALL TABLE) SECTION REFERENCE ANCHOR BOLT ABOVE FINISHED FLOOR CAST IN PLACE CONCRETE EXISTING SHEARWALL EDGE NAIL ENGINEER OF RECORD EACH WAY FOUNDATION FINISHED FLOOR GIRDER TRUSS GYPSUM WALL BOARD HEADER SEE STRUCTURAL NOTES LOAD BEARING WALL MANUFACTURER NEW ON CENTER PRE-ENGINEERED PRESSURE TREATED SHEARWALL TOP OF FRAMING TOP OF WALL UNLESS NOTED OTHERWISE VERIFY IN FIELD FOR SIZE) SHEAR WALL (SW) AND ANCHORAGE SCHEDULE (HEM -FIR) (0) Label ASD S.W. Capacity (PLF) seismtcnd Minimum Required APA Rated Sheathing (panel) (A) (B) (C) (D) (N) Panel Edge Nailing ®Sheathing Edges (D) (E) (K) Stud & Blocking Size ®Adjoining Panel Edges (C) (F) (L) Rim Joist Or Block Connection To Top Plate (G) (H); (Does not apply to crawlspace) 2x Bottom Plate Attachment Sill Plate Attachment (0)Anchor Bolt & Spacing To Concrete Below (J) (K) (M) Sill Plate Size ®Fdn. Nailing To Wood Below (I) SW6 242/339 zti6'"OSB (1) Side 0.131x2Y2" @ 6" O.C. 2x_ LTP4 @ 36"OC 16d @ 6" O.C. OR 12d @ 4" O.C. 5Y8" @ 48" O.C. 2x SW4 350/495 316'"OSB (1) Side 0.131x2Y2" @ 4" O.C. 2x_ LTP4 @ 20"OC 16d @ 4" O.C. 12d @ 3" O.C. . 5/8" @ 32" O.C. 2x MANDATORY NOTES A. ALL SHEATHING PANELS SHALL BE INSTALLED HORIZONTALLY WHERE FRAMING EXCEEDS 16" O.C. SPACING. BLOCK ALL PANEL EDGES. B N/A C. BLOCK ALL SHEATHING PANEL EDGES D. SHEARWALL SHEATHING/NAILING SHALL BE PROVIDED THE ENTIRE LENGTH OF THE WALLS INDICATED ON THE PLANS. ENDS OF FULL HEIGHT SHEARWALLS ARE DESIGNATED BY EXTERIOR BUILDING CORNERS, CORRIDORS, WALL PENETRATIONS OR AS DESIGNATED ON THE PLANS. SEE PLANS & TABLE FOR REQUIRED HOLDOWNS (ALL SHEARWALLS REQUIRE SHEATHING ABOVE & BELOW OPENINGS WITH SAME NAIL PATTERN). E EDGE NAIL SHEATHING AT ALL HOLDOWN POST/STUDS. EDGE NAILING IS REQUIRED TO EACH STUD USED IN A BUILT-UP HOLDOWN POST (MULTIPLE 2X STUDS). SEE TYPICAL DETAILS FOR FURTHER INFORMATION. F INTERMEDIA " TE STUDS SHALL BE 2X_ MINIMUM AND NAILED WITH 0.131"0 X 2Y2" FIELD NAILING AT 12" O.C. (WHERE STUD SPACING EXCEEDS 16O.C. PROVIDE FIELD NAILING @ 6" O.C.) G. USE 0.131"Ox2Y2" NAILS TYPICALLY FOR LTP CLIPS WHEN INSTALLING OVER SHEATHING. IF LTP CLIPS ARE INSTALLED DIRECTLY TO FRAMING, 0.131"OX1Y2" NAILS MAY BE USED. LTP CLIPS MUST BE INSTALLED WITH LONG DIMENSION HORIZONTALLY. A35 OR RBC CLIPS MAY BE USED WHEN ATTACHING ROOF BLOCKING TO TOP PLATE. H. LTP4'S NOT REQ'D WHERE RIM SHEATHING OVERLAPS THE SECOND FLOOR BOTTOM PLATE. I' SHEATHING SHALL BE CONTINUOUS OVER BOTTOM PLATE AND RIM OR SILL PLATE PER TYPICAL DETAILING WITH EDGE NAILING AT EACH. WHEN TWO ROWS OF NAILING ARE REQ'D AT DOUBLE SIDED SHEARWALLS SEE TYPICAL DETAILING FOR FASTENERS AND BLKG. J. ALL ANCHOR BOLTS SHALL HAVE STEEL PLATE WASHERS 0.229"x3"X3". ANCHOR BOLTS W/ STANDARD 90' BEND SHALL BE EMBEDDED 7" INTO CONCRETE. PLATE WASHERS SHALL EXTEND TO WITHIN Y2" OF SHEATHING EDGE. K. PROVIDE "HOT -DIPPED" GALVANIZED NAILS/BOLTS AND METAL CONNECTORS WHEN ATTACHING TO PRESSURE TREATED MATERIALS. L WHERE 3x STUDS ARE REQ'D AT ADJOINING PANEL EDGES (2) 2x STUDS MAY BE NAILED TOGETHER IN PLACE OF USING A SINGLE 3x. FACE NAIL STUDS TOGETHER W/ 16d AT SAME SPACING SHOWN IN 2X BOTTOM PLATE ATTACHMENT COLUMN. PANEL EDGE NAILING IS REQUIRED TO EACH OF THE DOUBLE STUDS AND SHALL BE STAGGERED M. POST INSTALLED ANCHORS MAY NOT BE A VIABLE ALTERNATIVE. CONTACT PHILLIPS STRUCTURAL ENGINEERING FOR CONSULTATION. N. APA RATED PLYWOOD MAY BE USED IN PLACE OF OSB 0. ALL NAILING SHALL BE PER IBC TABLE 2304.10.1 U.N.O. HOLDOWN AND STRAP TABLE Holdown Label (G) Simpson Strong -Tie Product Label (SKU) (A) (B) (C) (F) G H Strap/Holdown Attachment and Required Fasteners Anchorage to Foundation (D) Required NAILING and Boundary Studs Required SCREWS and Boundary Studs [1] STHD14/STHDI4RJ (2) 2X STUDS W/ (30) 0.148"Ox3Y4' NAILS N/A EMBEDDED STRAP [1]Alt HDU5-SDS2.5 N/A (2) 2X STUDS W/ (14) Y4"x2Y2" SIDS SCREWS SIMPSON SB%x24 MANDATORY NOTES A. INSTALLATION OF ALL HOLDOWN ANCHORS AND STRAPS SHALL BE PER THE MANUFACTURE'S RECOMMENDATIONS B ALL METAL CONNECTORS IN CONTACT WITH PRESSURE TREATED (P.T.) MATERIAL SHALL BE COATED WITH SIMPSON "Z-MAX" (G-185) GALVANIZATION, TRIPLE ZINC COATED FOR CORROSION PROTECTION. SUPPLEMENTAL NOTES C. ALTERNATE HOLDOWN TYPES MAY BE ACCEPTABLE WITH WRITTEN APPROVAL OF PHILLIPS STRUCTURAL ENGINEERING. D. ALTERNATE ADHESIVE ANCHORS MAY BE AVAILABLE, CONTACT PHILLIPS STRUCTURAL ENGINEERING E. N/A F. STHD14RJ HOLDOWNS ARE TYPICALLY TO BE INSTALLED WHERE A RIM JOIST OCCURS. G.1 SIMPSON HDU5-SDS2.5 MAY BE USED AS AN ALTERNATE TO STHD14(RJ). H. STRAPS MAY BE INSTALLED OVER SHEATHING RESUB 1Mr1-*FZ1yX CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PANEL EDGE NAILING PANEL EDGE BOUNDARY (STAGGER NAILING @ PANEL EDGES) NAILING (6" O.C. MAX. SPACING) JOISTS/TRUSS/RAFTER PER PLAN TYPICALLY - FACE NAIL DOUBLE TOP PLATES W/ 0.131"� X 3" @ 12" O.C. STAGGERED BEAM PER SIMPSON ST6224 W/ (28) RIM JOIST/BLOCKING PLAN 0.1620 x 2Y2" NAILS (CENTER ON SPLICE) 4'-0" MIN L II II II II II " 1-1/2" MIN [MIN I DOUBLE 2X TOP PLATE II II II (12) 0.131"0 x 3" LONG P-NAIL @ EACH INTERMEDIATE FRAMING II II SPLICE U.N.O. (FIELD) MEMBER NAILING I`I II I`I I II II (12" O.C. MAX. SPACING) I II II I°I I°I I°I (2) ROWS OF (4) 16d NAILS II LI SPLICE SPLICE NOTES: II II II II II II II 'I I I I I li I I I 1.) PROVIDE APA APPROVED GLUE, (2) 2x KINIGPM N NAIL ALL PLYWOOD TO JOISTS II II II II I°I TYP. PER GENERAL NOTES I.I I°I II I STUD TYPICAL WALL FRAMING 2.) STAGGER PANELS TO OFFSET I.I LI LI LI IL JOINTS AS SHOWN. II II II II II STUD @ BOT SPLICE 3/4" T&G PLYWOOD OR OSB NOTE: LOCATION (TYP) SHEATHING AT FLOOR & 7/16" WHERE PLATE DISCONTINUITIES ARE CREATED BY BEAMS SHEATHING AT ROOF (APA RATED) & PIPES, ETC. STRAP W/ (1)-SIMPSON ST6224 UNLESS NOTED OTHERWISE. STRAP MAY BE PLACED ON TOP OR SIDE OF PLATES @ CONTRACTOR'S OPTION. TYPICAL HORIZONTAL PLYWOOD DIAPHRAGM LAYOUT 1 (ROOF AND FLOOR) 2 TYPICAL TOP CHORD SPLICE 3 BEAM FLUSH TO DBL TOP PLATE PHLLPS SVFHD ��RLr11L ERMHESD�I IMPORTANT FRAMING NOTE: GENERAL CONTRACTOR/FRAMER SHALL VERIFY ALL CONCENTRATED LOADS FROM ABOVE TO HAVE SOLID BEARING CONTINUOUS TO THE FOUNDATION (INCLUDING SQUASH BLOCKING IN CRAWLSPACE/FLOOR FRAMING). ANY CHANGES TO FOUNDATION AND STRUCTURE FROM ARCHITECTURAL PLANS SHALL BE NOTED AND ALL AFFECTED PARTIES SHALL BE NOTIFIED. TYPICAL FRAMING NOTES: 1. Roof and floor diaphragm nailing per Wood Sheathing Notes. 2. Solid blocking shall be provided between the bearings of every rafter or truss. Attach every rafter & truss to framing with Simpson H2.5T or clip indicated in typical detailing. 3. Provide solid built-up studs or posts under all girder trusses, roof beams and floor beams. Solid blocking (squash blocking) is required in all floor cavities under built-up studs/posts. Built -ups or posts shall run continuous to the foundation. 4. Exterior walls shall be nailed & detailed per SW6 U.N.O. All panel edges shall be blocked per shearwall table. 5. Where (2) shearwalls meet at a corner/intersection, the sheathing of each wall shall be edge nailed to the studs/post which the holdown is attached to. 6. Provide a solid rim joist where floor joist bear on exterior walls per typical details. 7. Where floor framing runs parallel to exterior walls, install 2x or I -joist blocking panels between rim joist and first joist @ 48" o.c. - nail sheathing to blocking w/ 8d @ 3" o.c. (crawlspace framing where rim joist bears on concrete stemwalls are omitted from this requirement). 8. Roof and floor joists/trusses are shown schematically on the plan and are not intended to show every location of every joist/truss. 9. Provide double joists under interior partition walls when running parallel to each other. 10. Top plates are assumed to be continuous and may be spliced per typical detailing on this sheet. 11. All columns not specified or shown on the plans are to be a minimum of (2) 2x studs spike laminated together with 16d nails @ 6" o.c. (stagger). 12. All post -beam intersections shall contain positive connections to resist against uplift and/or lateral displacement. 13. Anchorage of walls to the foundation shall be provided in accordance with the shearwall schedule. 14. Typical Walls shall be framed with Hem -Fir U.N.O. 15. Walls shall be anchored to the foundation per the minimum requirements of SW6 (5/" 0 A.B. @ 48" o.c. embedded 7" and no more than 12" from ends of each sill and 2 bolts minimum) with 3"x3"x%4" square washers firmly attached between plate and nut. 16. All walls over 1 O' tall shall have bracing/blocking at 48" o.c. (flat or on edge). Z 0 a U U) w 0 � 0 Z 0 �) > w w w H Q 0 Q w 0 w PHILLIPS STRUCTURAL ENGINEERING PO Box 108, Milton, WA 98354 Phone: (253) 344-1666 www.PhillipsSE.com AS CIO ., ww ,off �U 3 394 L �w s o L�� 7/21 /2022 ALL VARIATIONS FROM DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS SHALL BE REPORTED TO THE DESIGNER FOR RESOLUTION WITH THE ENGINEER PRIOR TO PROCEEDING WITH WORK, FAILURE TO COMPLY BY THE CONTRACTOR SHALL BE THEIR SOLE RESPONSIBILITY FOR ANY COSTS NECESSARY FOR REMEDIAL WORK. REUSE OF DOCUMENTS UNAUTHORIZED ALTERATION OF ANY OF THE INFORMATION ON THIS DOCUMENT WILL INVALIDATE THE DOCUMENT, ENGINEER'S SEAL AND SIGNATURE. THE DESIGNS AND IDEAS INCORPORATED HEREIN, AS A TOOL OF PROFESSIONAL SERVICE, IS THE PROPERTY OF PHILLIPS STRUCTURAL ENGINEERING, PLLC AND IS NOT TO BE USED IN PART OR IN WHOLE BY ANY PARTY FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION FROM PHILLIPS STRUCTURAL ENGINEERING, PLLC. Z O N w00 Qrn 0 0 = Q cn o 0 Ur oo Z Z M �w J0 WIND SPEED: 110 MPH WIND EXPOSURE: B ROOF SNOW LOAD: 25 PSF GENERAL NOTES DRAWN BY: AIMS ORIGINAL DRAWING DATE: MAR. 23, 2022 SCALE N.T.S. (U.N.O.) PSE NUMBER: PSE 22.012 DESIGNER T2 SHEET NO: SRO I PHI LLI PS STRUCTURAL ENG NEER NG IF WALL @ STAIR EXCEEDS 48", VERTICAL REBAR SPACING TO BE AT 16" D.C. & H❑RIZ, @ 12" ❑,C, SIM, TO 2/SD-1 (N❑ FLOOR FRAMING) 5'-9" I v a FOOTING SCHEDULE 18"x18'x10' PLAIN 18" CONIC FTG 24"x24"x10" PLAIN 24" CONIC FTG 24"x24'x12" CONIC 24"R FTG W/(3)#4 E.W. 36"x36"x14" CONIC 36" FTG W/(5)#4 E.W. 0 CO I M CD o� ALL TEMPORARY SH❑RING OF EXISTING STRUCTURE FOR PLACEMENT OF NEW F❑UNDATI❑NS AND FRAMING IS BY OTHERS, EXISTING FRAMING SHALL REMAIN UNHARMED DURING THIS PROCESS. 8'-9" 2 --L---------J 'ETE STAIR —I—L_1— I 4x8 DF#2 I I Q Q I 00� J: I I L -0' 5'- 7" 3'-0" 4'-0' I (N) CRAWL SPACE I 6 MIL, BLACK VISQUEEN I VAPOR BARRIER 24" I L---- — — — r 4x8 DF#2 I I ------ `��j L—J18, --J I I 21-0" 3'-9�q" 3'-0" I I I I I I I I cai I cu I SEE 8/SD-1 I o o I I I v `D I I I I I �JJ I I 13'-1" �I I (N)2x10 HF#2 FLOOR (N) CRAWL SPACE JOIST @ 16" D.C. 6 MIL. BLACK VISQUEEN I I VAPOR BARRIER I I I 0 0� C C /--------------------------------- (E) Patio Ox8' SIMPS❑N TITAN HD UNDER IS WALL LINE @ 48" D.C. VT\A11\A /4r # \AA VTAAI IAA rMMKA rKMC --- — ----------------------- ❑O ❑O ❑O — — — — — — — — — — — — — — --------------- I I I I I I I I I I I I I I I I I (E) STEM/F❑❑TING I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I GARAGE EXISTING CONIC SLAB I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I j I I I I I I I I I I I I I 1 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ---------- --------------------- I I I } I I � I I w I I > I I I I N I I 1 I I 0 I 124" 1 I L — J`4x6 POST TIGHT FIT TO UNDERSIDE I 14'-11�q" OF SHEATHING CENTERED UNDER I IVERIFY LOAD FROM ABOVE(ATTACH TO BASE PER 7/SD-1); (2) L❑CATI❑NS I I I I NEW F❑❑TING (2) L❑CATI❑NS FOR SUPPORT OF NEW KITCHEN BEAM I I I I I I I I ATTACHMENT SIMILAR I EXISTING BUILDING NOTE: P,S,E, DID NOT EVALUATE THE TO 7/SD-1 TYP. o I I ENTIRE EXISTING RESIDENCE FOR STRUCTURAL INTEGRITY I I I AND IS NOT RESP❑NSIBLE FOR THE C❑NDITI❑N OF EXISTING o I I STRUCTURE, THE ADDITION HAS BEEN DESIGNED TO SUPPORT J c i I REC❑NFIGURED GRAVITY FORCES FROM INTERI❑R I DIRT SHELF I co M❑DIFICATI❑NS TO THE STRUCTURE, LOADS FROM INTERIOR cu M❑DIFICATI❑NS ARE CALCULATED TO BE SUPPORTED BY NEW ----------------------------------------vn ------------_ __1 �___� BEARING WALLS, BEAMS AND F❑UNDATIONS, DESIGN IS IN ACCORDANCE WITH THE 2018 IBC. ------------— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I I I I I I I I I 1 I I I ATTACH NEW TO EXISTING I I I I I I SD-1 STEMWALL/FOUNDATI❑N W/ I I I I I I I I #4x36" REBAR EMBEDDED 4" @ I I I I I I I I 24' ❑,C. MAX, (MIN. 1 T&B) W/ I I I I I I I I SIMPS❑N AT-XP ADHESIVE TYP, I I I I I I I I I I I I I I I I VERIFY ANCHOR BOLTS IN CRAWL SIM, TO 2/SD-1 & IL— — — — — — — — — — i I I I 5'-9" 8'-9" RETR❑FIT W/ 5/s"Ox8" SIMPS❑N TITAN HD @ 48" ❑,C. MAX. — — — — — — — — — — — — — — — I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I L �J I — — — — — — — — — I I I L------------------- .� I -------- ---------------� o o I o (E)8" CMU 3'-4" TALL I N I I I a I 8" CMU 3'-4" TALL�,� I ~ 14'-74" (VERIFY) I o I (E) BASEMENT K12 — ® 24 i o EXISTING SOIL BASE SD- I I I '-5" 3'-3" 4'-8" 3'-11"I I I I ��2 +1b +° __ +�+°` I (E)6x8 BEAM I `<,I I `� I 6�1 (E)6x8 BgAM ��" 1 c L` 8'-2" 6'-11' 00 I (u w +(b I b (E)6x8 BEAM I L�`_',I I I (E)6x8 BEAM I I L(E)24i L — 24J L (E)24" L — 24' L (E)J24" L CE)24" I I ti� ti� ti� I T QV I o I I � I NEW F❑❑TINGSVIPOUR ER (E) POSTS W/ Qj FOUNDATION PLAN SCALE : Y4" = 11-0" RES U B Jul 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W a O U W U Z 7 p O z a z z U 0 U) Ly cn 5; p Z W IY co O_ O Ir z w 01 3: O w Q N N N p N t` J � W p W W PHILLIPS STRUCTURAL ENGINEERING PO Box 108, Milton, WA 98354 Phone: (253) 344-1666 www.PhillipsSE.com .off 3 394 Lti S01 L�yG 7/21 /2022 ALL VARIATIONS FROM DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS SHALL BE REPORTED TO THE DESIGNER FOR RESOLUTION WITH THE ENGINEER PRIOR TO PROCEEDING WITH WORK; FAILURE TO COMPLY BY THE CONTRACTOR SHALL BE THEIR SOLE RESPONSIBILITY FOR ANY COSTS NECESSARY FOR REMEDIAL WORK. REUSE OF DOCUMENTS UNAUTHORIZED ALTERATION OF ANY OF THE INFORMATION ON THIS DOCUMENT WILL INVALIDATE THE DOCUMENT, ENGINEER'S SEAL AND SIGNATURE. THE DESIGNS AND IDEAS INCORPORATED HEREIN, AS A TOOL OF PROFESSIONAL SERVICE, IS THE PROPERTY OF PHILLIPS STRUCTURAL ENGINEERING, PLLC AND IS NOT TO BE USED IN PART OR IN WHOLE BY ANY PARTY FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION FROM PHILLIPS STRUCTURAL ENGINEERING, PLLC. z > N O Lu 00 Q05 = Cn O 0 Ur co Z Z cr Q (0 w WIND SPEED: 110 MPH WIND EXPOSURE: B ROOF SNOW LOAD: 25 PSF FOUNDATION PLAN DRAWN BY: AMS ORIGINAL DRAWING DATE: MAR. 23, 2022 SCALE: N.T.S. (U.N.O.) PSE NUMBER: PSE 22.012 DESIGNER: T2 SHEET NO: S-1 J J Z mes PHI LLI PS S"TRUCTURAL ENG NEER NG PHI LLI PS STRUCTURAL ENG NBER NG n d VERIFY ALL DIMENSIONS ON SITE AND REPORT ANY DISCREPANCIES BACK TO PHILLIPS STRUCTURAL ENGINEERING FOR FURTHER EVALUATION. / MAIN FLOOR SHEAR WALLS, HOEDOWNS, AND STRUCTURE SCALE: %4" = V-0" EXISTING BUILDING NOTE: P,S,E, DID NOT EVALUATE THE ENTIRE EXISTING RESIDENCE FOR STRUCTURAL INTEGRITY AND IS NOT RESP❑NSIBLE FOR THE C❑NDITI❑N OF EXISTING STRUCTURE. THE ADDITI❑N HAS BEEN DESIGNED TO SUPPORT REC❑NFIGURED GRAVITY FORCES FROM INTERI❑R M❑DIFICATI❑NS TO THE STRUCTURE. LOADS FROM INTERI❑R M❑DIFICATI❑NS ARE CALCULATED TO BE SUPPORTED BY NEW BEARING WALLS, BEAMS AND F❑UNDATI❑NS, DESIGN IS IN ACCORDANCE WITH THE 2018 IBC, ALL SHEARWALL TYPE NAILING PATTERNS SHALL BE VERIFIED AND HAVE THE MINIMUM SHEATHING AS INDICATED ON SHEET S-0 FOR SHEARWALL TYPE. ALL SHEARWALL DETAILING INCLUDING HARDWARE SHALL BE VERIFIED AND INSTALLED RES U B Jul 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W a O U U) W U z O Q �_ a U) z 0 U) W Q W W U)0 z z 0-1 W 0 Ln W z w a O of W N O QN Q N n H J W Q ; W W Ir PHILLIPS STRUCTURAL ENGINEERING PO Box 108, Milton, WA 98354 Phone: (253) 344-1666 www.PhillipsSE.com C ,.d� 3 394 L SO LyG 7/21 /2022 ALL VARIATIONS FROM DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS SHALL BE REPORTED TO THE DESIGNER FOR RESOLUTION WITH THE ENGINEER PRIOR TO PROCEEDING WITH WORK; FAILURE TO COMPLY BY THE CONTRACTOR SHALL BE THEIR SOLE RESPONSIBILITY FOR ANY COSTS NECESSARY FOR REMEDIAL WORK. REUSE OF DOCUMENTS UNAUTHORIZED ALTERATION OF ANY OF THE INFORMATION ON THIS DOCUMENT WILL INVALIDATE THE DOCUMENT, ENGINEER'S SEAL AND SIGNATURE. THE DESIGNS AND IDEAS INCORPORATED HEREIN, AS A TOOL OF PROFESSIONAL SERVICE, IS THE PROPERTY OF PHILLIPS STRUCTURAL ENGINEERING, PLLC AND IS NOT TO BE USED IN PART OR IN WHOLE BY ANY PARTY FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION FROM PHILLIPS STRUCTURAL ENGINEERING, PLLC. z > N 0 wC) Q05 0 IZ _ Q (n O 0 Ur 00 Z Z c� J�w WIND SPEED: 110 MPH WIND EXPOSURE: B ROOF SNOW LOAD: 25 PSF MAIN FLOOR SHEAR WALLS, HOLDOWNS, AND STRUCTURE DRAWN BY: AMS ORIGINAL DRAWING DATE: MAR. 23, 2022 SCALE: N.T.S. (U.N.O.) PSE NUMBER: PSE 22.012 DESIGNER: T2 SHEET NO: S-2 J J n 00 0 N PHI LLI PS STRUC,'TURAL ENG NEER NG PHI LLI PS STRUCTURAL ENG NBER NG 51 AL PER ROOF FRAMING SCALE: Y4" = 1'-0" ROOF TRUSSES BY OTHERS EXISTING BUILDING NOTE: P,S,E, DID NOT EVALUATE THE ENTIRE EXISTING RESIDENCE F❑R STRUCTURAL INTEGRITY AND IS NOT RESP❑NSIBLE FOR THE C❑NDITI❑N OF EXISTING STRUCTURE, THE ADDITI❑N HAS BEEN DESIGNED TO SUPPORT REC❑NFIGURED GRAVITY FORCES FROM INTERI❑R M❑DIFICATI❑NS TO THE STRUCTURE, LOADS FROM INTERI❑R MODIFICATIONS ARE CALCULATED TO BE SUPPORTED BY NEW BEARING WALLS, BEAMS AND F❑UNDATI❑NS, DESIGN IS IN ACCORDANCE WITH THE 2018 IBC. RESUB Jul 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W a O U U) w U z o Q w a U) z U U) 0 U) Q W 0 z o Of z O LLI w z LLI Ir O Ir W N O QN Q N n H J � W Q ; w W IY PH LL PS STRUCTURAL ENGINEERING PO Box 108, Milton, WA 98354 Phone: (253) 344-1666 www.PhillipsSE.com 3 394 L �yw S O L PCs 7/21 /2022 ALL VARIATIONS FROM DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS SHALL BE REPORTED TO THE DESIGNER FOR RESOLUTION WITH THE ENGINEER PRIOR TO PROCEEDING WITH WORK; FAILURE TO COMPLY BY THE CONTRACTOR SHALL BE THEIR SOLE RESPONSIBILITY FOR ANY COSTS NECESSARY FOR REMEDIAL WORK. REUSE OF DOCUMENTS UNAUTHORIZED ALTERATION OF ANY OF THE INFORMATION ON THIS DOCUMENT WILL INVALIDATE THE DOCUMENT, ENGINEER'S SEAL AND SIGNATURE. THE DESIGNS AND IDEAS INCORPORATED HEREIN, AS A TOOL OF PROFESSIONAL SERVICE, IS THE PROPERTY OF PHILLIPS STRUCTURAL ENGINEERING, PLLC AND IS NOT TO BE USED IN PART OR IN WHOLE BY ANY PARTY FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION FROM PHILLIPS STRUCTURAL ENGINEERING, PLLC. z > N O w00 QCF) a- _ (n O 0 Ur 00 Z Z co �w J� WIND SPEED: 110 MPH WIND EXPOSURE: B ROOF SNOW LOAD: 25 PSF ROOF FRAMING DRAWN BY: AMS ORIGINAL DRAWING DATE: MAR. 23, 2022 SCALE: N.T.S. (U.N.O.) PSE NUMBER: PSE 22.012 DESIGNER: T2 SHEET NO: S-3 r•� co co O N PHI LLI PS STRUCTURAL ENG NEER NG GWB PER ARCH. 2x6 STUDS @ 16' O.C. 2x6 P.T. SILL PLATE W/ V A.B. PER PLAN; 12' FROM ENDS 3/4 T&G PWD/OSB FLOOR JOISTS PER PLAN INSULATION PER ARCH, (1) #4 CONT, BAR #4 VERT./HORIZ, BAR @ 24' D.C, MAX SPACINGi - MIN. (1) T&B OF WALL 6' STEMi 36' MAX, HEIGHT VAPOR BARRIER @ CRAWL (2) #4 CONT. BARS— 6a 12" 2x BLOCKING 3/4' T&G PWD/❑SB� mww, 'x x I I X X I MIN, (4) 0.148'Ox3'_X_ _ NAILS TO POST & BEAM EACH SIDE 1x6x24' OR EQUIV. 3/4'—�_ OSB EACH SIDE OF BEAM OR SIMPS❑N AC SIMPSON PB44/46 OR (2) A34 AT POST BASE I Li NOTE, ATTACH EACH A34 TO FTG. W/ A PER FDN PLAN MINIMUM OF (2) POWDER 11 ACTUATED FASTENERS (1' EMBED) ROOF SHEATHING PER PLAN W/ 6"/12" NAIL PATERN U.N.O. 12 PER PLAN P,E. TRUSS, REFERENCE MFR, SHOP DRAWINGS - GYPSUM BOARD PER ARCH 2 X 6 STUD WALL - - STUDS @ 16" O.C. "SIMPSON" SDWC MAY BE SUBSTITUTED FOR THE TYPICAL H2.5T CALLOUT INSTALLED PER MANUFACTURER'S RECOMMENDATIONS INSULATION PER ARCH. SHEATHING PER PLAN MOISTURE BARRIER & SIDING PER ARCH, (NOT SHOWN) BOTTOM PLATE NAILING PER S.W. SCHED. EDGE NAILING PER S,W, SCHED, CONT. 2x RIM J❑IST TOE NAILING 3'x0,131' @ 6' O.C. EXTERIOR GRADE 00 X m: Q Z_ M /\ �0 FTG AND TIGHT LINE DRAINS AS REW D u FLOOR JOISTS PER PLAN; LAP & FACE NAIL W/ (4) 0,148'Ox3' NAILS MIN, GWB PER ARCH, 2x6 STUDS @ 16' O.C. P,T. 2x6 SILL PLATE W/ V A.B, PER PLAN; 12' FROM ENDS :Y4' T&G PWD/OSB FLOOR JOISTS PER PLAN INSULATION PER ARCH, (1) #4 CONT, BAR - #4 VERT./HORIZ. BAR. @ 24' O.C, MAX SPACINGi MIN. (1) T&B OF WALL 8' STEMi 48' MAX, HEIGHT VAPOR BARRIER @ CRAWL\ (2) #4 CONT. -INSULATION PER ARCH, SHEATHING PER PLAN MOISTURE BARRIER & SIDING PER ARCH, (NOT SHOWN) BOTTOM PLATE NAILING PER S.W. SCHEDULE EDGE NAILING PER S.W. SCHED. CONT, 2x RIM J❑IST (I:Y4 LVL @ I -JOISTS) TOE NAIL 3'x0,131' @ 6' O.C. EXTERIOR GRADE s Z X 00 Q a 4a L FTG AND TIGHT LINE DRAINS AS REWD a 8 DOUBLE 2X a STUD (MIN) J z BUNDLED STUDS PER HOLDOWN TABLE —BEAM PER PLAN SPA N —4x4 POST OR 4x6 @ BEAM FRAMING C�EOR A 7' SPLICE U.N,O, '''� MAX MUM (6' MAX, POST HEIGHT) \ 30" MIN. K.:w❑NE #4 REBAR �15# BUILDING PAPER ,:;-.r, BETWEEN POST & CONC. REBAR . ,;t y�. ., LENGTH IN SHEAR CONE i,2 MIN. 12' MIN. .• FROM REBAR RNER (LENGTH SimSTHDon I4RJ With9-Tie P Rim Joist Installation STHD14RJ HOLDOWN DETAIL 7 8 NOTE: WHEN GABLE EXCEEDS 10' TRUSS MFR TO PR❑VIDE ADDITI❑NAL BRACING, SIMPSON H2.5T OR EQUAL (4) 16d FROM BRACE 8d @ 6' ❑ C TO BLK'G 0 EPDXY INSTALLATION MAY NOT BE USED AS AN ALTERNATIVE TO CAST IN PLACE ANCHORS. CONTACT P.S.E. FOR POTENTIAL ALTERNATIVES HDU5-SDS2.5 HOLDOWN (HDU2/HDU4 SIMILAR) @ EACH TRUSS, TYP. TO BLK'G P,E, TRUSSES @ 24' D.C. RBC OR RBCP @ 48" O.C. (INSTALL @ ENDS WHERE INTERFERES W/ VENT HOLES) 2x4 BLK'G CUT T❑ FIT 16d @ 6" D.C. EDGE NAILING INTO BLK'G 2X BIRD BL❑CKING W/ VENT HOLES a x w 0_ L3 w BTWN TRUSS TOP CHORDS @ DIAG. BRACE SPACING ol 2x4 DIAG. BRACE @ 48" D.C. WHERE REQ'D 1x4x8' BRACING @ 48' D.C. W/ (2) 1Od NAILS @ EA. TRUSS (2x4 BRACE PERMITTED).- A _ 0 = A34 FROM 2x4 BRACE TO 2x4 NAILER (4) 16d MIN, 2x TO 2x AT BRACES, TYP oo (2) 16d FROM 2x4 TO 2x6 CONT, - S,W, EDGE NAILING a W VERT, GABLE WEBS -2X6 DBL TOP PLATE o �f6" SHEATHING, WHERE oCL w REQ'D, ON GABLE ENDS - VAPOR BARRIER/ z = r — SIDING PER ARCH. P.E, TRUSS PER PLAN SHEATHING PER S.W. � ` SCHEDULE 1x4x8' BRACING @ 48" L ��SEE TOP PLATE SHEATH GABLE END AND ATTACH PER MIN, S.W, REQ. 16d @ 6" ❑,C, TRUSS TO 2x6 BEYOND S.W, EDGE NAILING PER PLAN SHEATHING PER PLAN D.C. W/ (2) 10d NAILS C❑NNECTI❑N DETAIL TYPICAL GABLE END TO @ EA, TRUSS (2X4 BRACE PERMITTED) TOP PLATE CONNECTION 13 TYP. GABLE END WEB BRACING 14 15 CMSTCI6 X RIM DEPTH + 66" FROM PONY WALL BELOW TO SHEAR WALL ABOVE WHERE - FOUNDATION HOLDOWN IS SPECIFIED; OVERLAP CMSTC STRAP W/ STHD BELOW AS NEEDED. ALIGN HOLES AND INSTALL NAILING THROUGH BOTH STRAPS. RIM JOIST DOUBLE 2X6 TOP PLATE 2x6 CRIPPLE WALL WITH STUDS @ 16" O.C., MAX HEIGHT 48";--,-_ SHEATHING/NAILING TO MATCH S.W. SPECIFICATIONS OF WALL ABOVE STHD, HDU OR OTHER HOLD DOWN _ PER PLAN MINIMUM (2) A.B. @ EA. STEP LEVEL OR PER S.W. SCHEDULE TYPICAL REINFORCING PER FOUNDATION OR RETAINING WALL SCHEDULE VERIFY (E) NAIL @ 6" D.C. MAX. 86 @ 6' D.C. I 1601 @ 6" D.C. P.E. TRUSS @ 24' D.C. (E) WALL TO BE REMOVE MAX STEP HEIGHT OF ONE UNIT VERTICAL PER TWO UNITS H❑RIZ❑NTAL WALL FRAMING ABOVE � LOCATE A.B. 12" FROM ENDS TYP. PROVIDE (1) SIMPSON CS16 STRAP 48" MIN. EACH SIDE OF SILL PLATE PLICE W/ (22) 0.148x2Y2" COMMON NAILS 2x6 BOTTOM PLATE P.T. SILL PLATE PER PLAN (2) #4 BAR 42" LONG .............................. PLACE DIAGONALY @ LL, STEPS AS SHOWN IN / FOUNDATION WALLS ....... :............. :................... f 12" MIN. 8" MAX STEM WALL .................................. /....................:./.� HEIGHT :.. . / r....................... y,,,.,,:1 \\� pip "1C I•• / STEP FTG WHERE REQ D, a \ /\� • CONT. REBAR PER TYP. -J /\\D A 2 MIN- FTG DETAIL (MIN. LAP i ��\�j\\�\\ SPLICE AS REQ'D) -FTG. DEPTH PER PLAN 10 (E) RAFTER AND ROOF DECKING (E)C.J. @ 16" D.C. 16 SIMPS❑N DDT1Z FROM CEILING J❑IST TO NEW BEAM W/ SDWH SCREW EMBEDDED 3' MIN.; SPACE AT 48' ❑.C, MAX EA, SIDE (STAGGER) (E) 2x6 CEILING-' J❑IST @ 16' D.C. ALTERNATE TO DDT1Z; LSTA24 TO BOTTOM OF CEILING J❑ISTS CIF ALIGNED) @ 48' D.C. MAX. 11 (N) TRIPLE 13/4'x117/8' LVL PER PLAN; FACE NAIL W/ (2) ROWS OF 16d @ 6" D.C. STAGGERED �I (E) GWB US26 TYP, 17 11) I 20 I 21 I 22 I 23 25 26 27 28 29 KITCHEN BEAM SUPPORT PER PLAN (E) FLOOR FRAMING POST SIM. TO 7/SD-1 (TIGHT FIT WITH BL❑CKING) CRAWLSPACE FTG. PER PLAN d n ° , —1 r .. d °• LINE OF INFLUENCE FROM NEW F❑❑TING TO EXISTING F❑❑TING, BOTTOM OF NEW F❑❑TING MUST BE DEEPENED AS SHOWN TO MAINTAIN 1:1 SLOPE OR LESS EXISTING FTG,/STEM / ° EXISTING F❑❑TING & CMU WALL IN CRAWL RESUB Jul 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 12 NO 24 30 w w O U 0 w U z Q O a z O_ co w Q W w cn z O Of Of O U) w z w a O W N N Q N J � W Q ; w w PHILLIPS STRUCTURAL ENGINEERING PO Box 108, Milton, WA 98354 Phone: (253) 344-1666 www.PhillipsSE.com AS . i 3 394�G1� s 0 L �1 7/21 /2022 ALL VARIATIONS FROM DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS SHALL BE REPORTED TO THE DESIGNER FOR RESOLUTION WITH THE ENGINEER PRIOR TO PROCEEDING WITH WORK; FAILURE TO COMPLY BY THE CONTRACTOR SHALL BE THEIR SOLE RESPONSIBILITY FOR ANY COSTS NECESSARY FOR REMEDIAL WORK. REUSE OF DOCUMENTS UNAUTHORIZED ALTERATION OF ANY OF THE INFORMATION ON THIS DOCUMENT WILL INVALIDATE THE DOCUMENT, ENGINEER'S SEAL AND SIGNATURE. THE DESIGNS AND IDEAS INCORPORATED HEREIN, AS A TOOL OF PROFESSIONAL SERVICE, IS THE PROPERTY OF PHILLIPS STRUCTURAL ENGINEERING, PLLC AND IS NOT TO BE USED IN PART OR IN WHOLE BY ANY PARTY FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION FROM PHILLIPS STRUCTURAL ENGINEERING, PLLC. z (0 > 0 CV Lu c:) � Qd) 0 � a o0 Ur 00 Z z �° �W J� WIND SPEED: 110 MPH WIND EXPOSURE: B ROOF SNOW LOAD: 25 PSF STRUCTURAL DETAILS DRAWN BY: AMS ORIGINAL MAR. 23, 2022 DRAWING DATE: SCALE: N.T.S. (U.N.O.) PSE NUMBER: PSE 22.012 DESIGNER: T2 SHEET NO: SD-1 J J n co