Updated Geo Letter 4.29.20COBALT G E 0 S C I E N C E S March 25, 2020 Troy Grasseth G2 Contracting G2contractingolive.com RE: Retaining Wall & Excavation Considerations Proposed Single -Family Residence 15712 — 72nd Avenue West Edmonds, Washington Cobalt Geosciences, LLC P.O. Box 82243 Kenmore, Washington 98028 In accordance with your authorization, Cobalt Geosciences, LLC has prepared this letter to discuss free-standing retaining wall construction east of the proposed residence at the referenced site. This letter follows our receipt and review of a third -party review letter by Landau Associates dated February 19, 202o as well as a recent site visit to observe the current site topography. Their letter discusses a previous 20 feet tall cut and not the 12 to 14 feet tall cut as described to us during our previous site visit. Observations and Recommendations We recently visited the site to observe the current topography. Based on our review, it appears that the proposed 10 feet tall concrete retaining wall east of the residence will be situated on buttress fill. We estimate that a 1.5H:1V (horizontal to vertical) temporary slope can be created safely in the buttress fill to allow for construction of the upper retaining wall, provided the wall is relocated to the west. Figure 1 shows the current topography and proposed wall location (original plans and recommended location), along with location of buttress fill. We added a 1.5H:1V temporary slope angle to illustrate a possible excavation to allow for basement wall construction and upper concrete wall construction. The originally proposed wall location would require steep temporary excavations in buttress fill that may not be stable. We recommend moving the retaining wall about 8 feet to the west of this location. This location will allow for wall construction while maintaining a 1.5H:1V slope in buttress fill up to 72nd Avenue West. Since the wall will be situated in fill, we recommend supporting the concrete wall on small diameter pipe piles driven to refusal in underlying glacial till. The following recommendations may be used in foundation design considerations for the concrete wall located in the yard area. The proposed concrete wall may be supported by small diameter driven steel pipe piles extending to refusal in the underlying dense to very dense native soils. Pin piles used for foundation support may consist of two, three, or four -inch diameter, Schedule 40 or 8o, galvanized steel pipes. Allowable axial compression capacities of 3, 6, and 10 tons may be used for these piles, respectively. www.cobaltgeo.com (2o6) 331-1097 March 25, 2020 Page 2 of 3 Geotechnical Recommendations The required pile length in order to develop the recommended pile capacity is expected to vary depending on the depth of loose/soft soils below the foundation elements. For estimating purposes, a pile length of about 15 to 25 feet may be anticipated. Three and four -inch diameter piles are typically installed using small (approximately 650 to 1,100 pound) hammers mounted to an excavator. Refusal criteria is the minimum amount of time (in seconds) required to achieve one inch of penetration, and it varies with the size of hammer used for pile driving. Penetration resistance required to achieve the capacities will be determined from the hammer size. The following is a summary of typical driving refusal criteria for different hammer sizes that are commonly used for three and four -inch diameter piles. Hammer Weight 3" Pile Refusal Criteria 4" Pile Refusal Criteria Hammer (lb) / Blows per (seconds per inch) (seconds per inch of minute penetration) Hydraulic TB 650 / 225 550 - 1100 12 20 Hydraulic TB 850 / 325 550 - 1100 10 16 Hydraulic TB 1,100 / 425 550 - 1100 6 10 Alternative hammer sizes may be used; however, the contractor should provide adequate information to verify equivalence and refusal criteria. Pile splices may be made with compression fitted sleeve pipe couplers (mechanical couplers). Two inch pin piles are driven with a 140 pound pneumatic hammer. Refusal criteria is 3 cycles of 30 seconds per inch of embedment. A total of 3 percent of the pin piles (one pile minimum) should be load tested to verify the design capacities. All load tests shall be performed in accordance with the procedure outlined in ASTM D1143. The maximum test load shall be 2 times the design load (i.e. 2 x 10 tons = 20 tons). A representative of the geotechnical engineer shall provide full time observation of pile installation and testing to verify the driving refusal criteria. We can provide additional recommendations upon request. Closure The information presented herein is based upon professional interpretation utilizing standard practices and a degree of conservatism deemed proper for this project. We emphasize that this report is valid for this project as outlined above and for the current site conditions and should not be used for any other site. The contractor and owner are responsible for project safety, risk to adjacent properties, and excavation stability. Sincerely, www.cobaltgeo.com (2o6) 331-1097 March 25, 2020 Page 3 of 3 Geotechnical Recommendations Cobalt Geosciences, LLC Pa�"ONry w ASyj�tAc�` ' - r 4 r'� n , 54898 r4 Exp. 6/26/2020 Phil Haberman, PE, LG, LEG Principal PH/sc www.cobaltgeo.com (2o6) 331-1097 MC014ELt PRL1E'EIiFYJCORN�R �` I I f _� k VN l s�\1 1 11 1 11 1 f n!F B i1 I 20, MAX — _ \ Section 1 1 1 1 1 1 AEfh1 WALL5PER "ABOVE I�- )"' �`� STRUCFURAL PAllO 1 5. PLANS PROPOSRD SFR. . ti R AfGAFAGEFFE--ti7.6" - • MAINFFF,=267.b 1 n 11 1 1 1 1 uopvc PPE=t7n.0 p WM if ..358..p 1111 1 j1 W � W 1 I 151� 1 lj If _ GARAGE I — I ENtRT 25B.0 1 i Not to Scale \\� a \ \ 1 \... .t \ `a '' - .• • r •� r EXIST 1CLU UTILITY a EASE Section Showing Current and Originally Proposed Wall Location Proposed Wall at 72nd Ave. W. 285 Proposed Location i 275' Proposed SFR / 265 / Fill Presumed / Former Cut ..........,. . ............... ........................ :' 255' / 1.5H:1V Slope" Native Glacial Till 1„_30, Section Showing Current Layout with Proposed Wall Location West of Original Location Proposed Wall 72nd Ave. W. 285 Location, —8' West of revious Location 275' Proposed Finish / Yard Grade / i 265' / Fill 255' / i 1.5H:iV Slope Glacial Till Cobalt Geosciences, LLC Proposed Residence P.O. Box 82243 1 12 end Avenue West Site Plan & Kenmore, WA 98028 COBALT57 % (2o6) 331-1097 Section G E 0 S C I E N C k S Edmonds, Washington www.cobaltgeo.com Figure i cobaltgeoogmail.com