Loading...
REV 2 Temporary Wall3For Exposed Wi Up To 6 Feet Dense to Very Dense Native Glacial Soils NOTES: For use with 2.5'x2.5'x5' interlocking concrete blocks (Ultra blocks) Figure is for total wall heights between up to 6 feet; single depth block wall with maximum 1.5H:1V backslope Wall designed for temporary (static only) conditions Level conditions in front of wall are required; no embedment proposed Cobalt to verify keyway, drainage, backfill, soil conditions, and block installation during construction All gravity walls to have a 6 degree batter Not to Scale P��HUNY�yq v 1� flF WA sy� 1-j 548s6 A!72 Exp.6-26-2020 Cobalt Geosciences, LLC Temporary Shoring Gravity Wall P.O. Box 82243 COBALT 15712 7 2nd Avenue W. Layout Kenmore, WA 98028 (206) 331-1097 Edmonds, Washington Figure 1 www.cobaltgeo.com cobaltgeo(cr�gmail.com