REV 2 Temporary Wall3For Exposed Wi
Up To 6 Feet
Dense to Very Dense
Native Glacial Soils
NOTES:
For use with 2.5'x2.5'x5' interlocking concrete blocks (Ultra blocks)
Figure is for total wall heights between up to 6 feet; single depth block wall
with maximum 1.5H:1V backslope
Wall designed for temporary (static only) conditions
Level conditions in front of wall are required; no embedment proposed
Cobalt to verify keyway, drainage, backfill, soil conditions,
and block installation during construction
All gravity walls to have a 6 degree batter
Not to Scale
P��HUNY�yq
v 1� flF WA
sy�
1-j 548s6 A!72
Exp.6-26-2020
Cobalt Geosciences, LLC
Temporary Shoring Gravity Wall P.O. Box 82243
COBALT 15712 7
2nd Avenue W.
Layout
Kenmore, WA 98028
(206) 331-1097
Edmonds, Washington
Figure 1
www.cobaltgeo.com