REV 5 REVIEWED BLD CALCULATION REPORTMAINLAND ENGINEERING CONSULTANTS CORPORATION
STRUCTURAL CALCULATIONS
OF
SINGLE FAMILY DWELLING
15712 - 72 AVE. WEST,
EDMONDS,WASHINGTON
PROJECT NO. UR801
2021-06-24
PREPARED BY:
MAINLAND ENGG. CONSULTANTS CORPORATION
SUITE 206 8363 128TH STREET
SURREY, B.C. V3W 4G1
PHONE - (604) 543-8044, FAX (604) 543-8104
MAINLAND ENGINEERING CONSULTANTS CORPORATION
INDEX
NO
PARTICULARS
CONTENTS
PAGE
1
LOAD CALCULATIONS
1
2
BEAMS CALCULATIONS
B-1 TO B-36
2 to 37
3
HEADER CALCULATIONS
H-1 TO H-2
38 to 39
4
FLOOR AND ROOF JOIST
CALCULATIONS
J-1 TO J-4, R-1 TO R-3
40 to 46
5
BUILDING LATERAL ANALYSIS
SEISMIC ANALYSIS
47 to 48
WIND ANALYSIS
49 to 50
6
LATERAL ANLYSIS SHEETS
FOR ROOF,UPPER FLOOR AND MAIN FLOOR
51 to 56
7
WALL LOAD CALCULATIONS
57
8
APPENDIX
A TO D
58 to 61
9
RETAINING WALL DESIGN
4 FEET, 6 FEET, 8 FEET AND 10 FEET
62 to 73
10
LATERAL FORCE RESISTING SYSTEM
CALCULATION
ALONG GRID LINE #A
74 to 80
MAINLAND ENGINEERING CONSULTANTS CORPORATION
Project:
SINGLE FAMILY DWELLING
Sheet
1
Location:
115712 - 72 AVE. WEST,EDMONDS WA
Job No.:
UR801
Date:
26-Aua-20
Bv:
IBS
Chk:
IAB
LOAD SHEET PER 2015 IBC (TABLE-1607.1)
ROOF LOAD IN PSF
1
FLOOR LOAD IN PSF
1-1/2" CONC TOPPING
17.00
BUILD UP/ROOFING
2.50
BUILD UP
1.00
SHEATHING (1/2")
1.75
SHEATHING (3/4")
1.50
FLAT ROOF JOIST@16" O.C.
5.00
FLOOR JOIST
2.00
CEILING JOISTS
1.80
CEILING: HARD
2.00
DRYWALL
2.20
MECH & ELECT
1.00
INSULATION
1.00
INSULATION: RIGID
0.00
MISC.
3.75
PARTITION
9.00
FUTURE SOLAR PANELS
0.00
MISC.
0.50
TOTAL D.L.
1 18.00
ITOTAL D.L.
34.00
LIVE LOAD (L.L.)
1 20.00
ILIVE LOAD (L.L.)"*
40.00
SNOW LOAD (S.L)
1 25.00
ITOTAL LOAD
74.00
- LIVE LOAD (STAIRS AND EXIT WAYS) = 100 PSF
TIMBER: WEST COAST USING DOUGLAS FIR
SIZE/GRADE Fb (SINGLE/REPITITIVE) Fv (PSI) E (PSI)
2 x NO. 2 1000 95 1700000
4 x NO. 2 1000 95 1700000
6 x NO. 2 1350 85 1600000
PARTITION DEAD LOAD
1/2" GYP. BOARD
4.5
STUD FRAMING
2.0
INSULATION
1.5
MISC
2.0
TOTAL LOAD 1 10.0
CONCRETE:
REINFORCED STEEL:
EXTERIOR WALL DEAD LOAD
STUCO
4.0
1/2" PLYWOOD
1.5
STUD FRAMING
2.3
INSULATION
1.5
1/2" GYP. BOARD
2.2
MISC
1 1.0
TOTAL
1 12.5
FOUNDATIONS AND SLAB ON GRADE 28 DAYS STRENGTH = 3000 PSI
INTERMEDIATE GRADE A60 AS PER ASTM 615
ALL BARS EXCEPT #2 SHALL BE DEFORMED
WELDED WIRE MESH AS PER ASTM A 185
i
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, 131
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
Overall Length: 10'
6 2,
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
5668 @ 6' 7 1/4"
11172 (5.50")
Passed (51%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
2165 @ 5' 3"
8571
Passed (25%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
4107 @ 3' 1 13/16"
21832
Passed (19%)
1.15
1.0 D + 1.0 S (Alt Spans)
Neg Moment (Ft-Ibs)
-2429 @ 6' 7 1/4"
16829
Passed (14%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.015 @ 3' 4 3/16"
0.212
1 Passed (L/999+)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.025 @ 3' 3 11/16"
0.318
1 Passed (L/999+)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 5' 9 9/16".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 3' 1/8".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Column - SPF
4.50"
3.25"
1.50"
1260
1818
3078
1 1/4" Rim Board
2 - Column - SPF
5.50"
5.50"
1 2.79"
2407
3261
5668
Blocking
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
8' 9" o/c
Bottom Edge (Lu)
8' 9" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 8' 10"
N/A
10.3
--
1 - Uniform (PSF)
0 to 8' 10" (Front)
22' 6"
18.0
25.0
Residential - Living
Areas
Member Notes
CANT.BEAM
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported 2
Page 3 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, 132
1 piece(s) 1 3/4" x 14" 2.0E Microllam@ LVL
Overall Length: 15' T
i
13' 3"
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
832 @ V 10 3/4"
3981 (3.50")
Passed (21%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
242 @ 7"
5353
Passed (5%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
-743 @ 1' 10 3/4"
13949
Passed (5%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.011 @ 0
0.200
Passed (2L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl.(in)
0.016 @ 0
0.200
Passed (2L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/0.2") and TL (2L/0.2").
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories If
Total
Available
Required
Dead
Snow
Total
1 - Beam - GLB
3.50"
3.50"
1.50"
384
447
831
Blocking
2 - Hanger on 14" GLB beam
3.50"
Hangers
1 1.50"
24
-32
24/-32
See note s
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
15' 4" o/c
Bottom Edge (Lu)
15' 4" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
2 - Face Mount Hanger
IUS1.81/9.5
2.00"
N/A
8-10dx1.5
2-10dx1.5
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 15' 3 1/2"
N/A
7.2
1 - Uniform (PSF)
0 to 1' 9" (Front)
9' 6"
18.0
25.0
ROOF LOADS
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported 3
Page 4 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, B3
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
Overall Length: 6' T
FBI
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
❑2
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1347 @ 2' 1 3/4"
4648 (3.50")
Passed (29%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
372 @ 3' 5"
8571
Passed (4%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
311 @ 4' 9 1/2"
21832
Passed (1%)
1.15
1.0 D + 1.0 S (Alt Spans)
Neg Moment (Ft-Ibs)
-717 @ 2' 1 3/4"
16829
Passed (4%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.002 @ 0
0.200
1 Passed (2L/999+)
I --
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.003 @ 0
0.215
1 Passed (2L/999+)
I --
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/0.2") and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 3' 3".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 3' 6 13/16".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
3.50"
1.50"
593
755
1348
Blocking
2 - Stud wall - SPF
3.50"
2.25"
1 1.50"
167
255
422
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
6' 6" o/c
Bottom Edge (Lu)
6' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 6' 5 3/4"
N/A
10.3
1 - Uniform (PSF)
0 to 2' 3" (Front)
7'
18.0
25.0
Residential - Living
Areas
2 - Uniform (PSF)
2' 3" to 6' 7" (Front)
5' 3"
18.0
25.0
Residential - Living
Areas
Notes
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported 4
Page 5 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, 134
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
2
0
Overall Length: I- 1
11 ' 6"
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
H
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
4149 @ 13- 11"
4570 (2.25")
Passed (91%)
1.0 D + 1.0 S (Alt Spans)
Shear (Ibs)
3436 @ T Y
8571
Passed (40%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
11793 @ 8' 2 1/16"
21832
Passed (54%)
1.15
1.0 D + 1.0 S (Alt Spans)
Neg Moment (Ft-Ibs)
-1645 @ 2' 1 3/4"
16829
Passed (10%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.147 @ 8' 3/4"
0.392
Passed (L/960)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.252 @ 8' 15/16"
0.589
1 Passed (L/560)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 11' 5 7/8".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 2' 6 7/16".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Column - SPF
3.50"
3.50"
2.89"
2509
3368
5877
Blocking
2 - Column - SPF
3.50"
2.25"
1 2.04"
1785
2438
4223
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
14' o/c
Bottom Edge (Lu)
14' o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 13' 11 3/4"
N/A
10.3
--
1 - Uniform (PSF)
0 to 14' 1" (Front)
16' 4 1/2"
18.0
25.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/w(>odproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported 5
Page 6 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, 135
1 piece(s) 1 3/4" x 14" 2.0E Microllam@ LVL
Overall Length: 22' a'
19' 6"
❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1292 @ 2' 4 3/4"
2603 (3.50")
Passed (50%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
748 @ T 8 1/2"
5353
Passed (14%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
3102 @ 12' 5 3/8"
10916
Passed (28%)
0.90
1.0 D (All Spans)
Live Load Defl. (in)
0.078 @ 12' 4 7/8"
0.659
Passed (L/999+)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.364 @ 12' 4 1/4"
0.989
Passed (L/652)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
3.50"
1.74"
842
450
1292
Blocking
2 - Stud wall - SPF
3.50"
2.25"
1 1.50"
648
182
830
1 1/4" Rim Board
• win board is assumes to carry aii ioaas appuea oirectiy above it, bypassing the memoer Ding aesignea.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
13' 8" o/c
Bottom Edge (Lu)
22' 3" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 22' 2 3/4"
N/A
7.2
1 - Uniform (PSF)
0 to 2' 9" (Front)
3' 9"
18.0
25.0
Residential - Living
Areas
2 - Uniform (PSF)
2' 9" to 22' 4" (Front)
9"
18.0
25.0
Residential - Living
Areas
3 - Uniform (PLF)
2' 9" to 22' 4" (Front)
N/A
45.0
-
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported 6
Page 7 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, 136
1 piece(s) 5 1/8" x 13 1/2" 24F-V4 DF Glulam
6' 3"
n
6' 9„
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
9126 @ 6' 5 1/4"
14991 (4.50")
Passed (61%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
4045 @ 7' 9"
14057
Passed (29%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
276 @ 12' 6 1/16"
35805
Passed (1%)
1.15
1.0 D + 1.0 S (Alt Spans)
Neg Moment (Ft-Ibs)
-17118 @ 615 1/4"
27599
Passed (62%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl.(in)
0.173 @ 0
0.429
1 Passed (2L/896)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl.(in)
0.377 @ 0
0.644
1 Passed (2L/410)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Left cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered.
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 1' 8 7/8".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 13' 2 3/16".
• -432 Ibs uplift at support located at 13' 4 1/2". Strapping or other restraint may be required.
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Supports
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Column Cap - steel
4.50"
4.50"
2.74"
4523
4604
9127
Blocking
2 - Hanger on 13 1/2" SPF beam
4.50"
Hanger'
1.50"
-150
1003/-283
1433
See note'
• ClocKmg Panels are assumeo to carry no loaas appnea airectry anove tnem ano the tun loaa is appnea to the member Deing aesigneo.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
13' 5" o/c
Bottom Edge (Lu)
13' 5" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
2- Face Mount Hanger
HUC5.125/12
2.50"
N/A
22-10dx1.5
8-10d
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported 7
Page 8 / 55
a" O R T CM MEMBER REPORT
UPPER FLOOR PLAN, 137
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
FAILED
An excessive uplift of -1635 Ibs at support located at 9' 5" failed this product.
4'9"
Overall Length: 9' 7"
C
4'
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
5610 @ 4' 10 3/4"
7109 (3.50")
Passed (79%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
2465 @ 6' 2"
8571
Passed (29%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
0 @ N/A
N/A
Passed (N/A)
--
N/A
Neg Moment (Ft-Ibs)
-9798 @ 4' 10 3/4"
16829
Passed (58%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.088 @ 0
0.326
Passed (2L/999+)
I --
1.0 D + 1.0 S (Alt Spans)
Total Load Defl.(in)
0.208 @ 0
0.490
Passed (2L/566)
I --
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Left cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered.
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 9' 5".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Column - SPF
3.50"
3.50"
2.76"
3027
2582
5609
Blocking
2 - Column - SPF
3.50"
2.25"
1 1.50"
-924
-711
-1635
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
9' 6" o/c
Bottom Edge (Lu)
9' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 9' 5 3/4"
N/A
10.3
1 - Uniform (PSF)
0 to 9' 7" (Front)
6' 9"
18.0
25.0
Residential - Living
Areas
2 - Point (lb)
1 3/16" (Front)
N/A
842
450
Linked from: B5,
Support 1
Notes
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported
Page 10 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, 138
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
2' 6"
1❑
Overall Length: I- -
11' 6"
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
❑2
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3753 @ 2' 7 3/4"
4648 (3.50")
Passed (81%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1996 @ 3' 11"
8571
Passed (23%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
6137 @ 8' 10 5/16"
21832
Passed (28%)
1.15
1.0 D + 1.0 S (Alt Spans)
Neg Moment (Ft-Ibs)
-2352 @ 2' 7 3/4"
16829
Passed (14%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.079 @ 8' 6 15/16"
0.392
Passed (U999+)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.129 @ 8' 7 3/4"
0.589
Passed (U999+)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 11' 1 3/8".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 3' 9 13/16".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1- Stud wall- SPF
3.50"
3.50"
2.83"
1767
387
1986
4140
Blocking
2 - Stud wall - SPF
3.50"
2.25"
1.68"
945
-71
1328
2271/
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
14' 6" o/c
Bottom Edge (Lu)
14' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 14' 5 3/4"
N/A
10.3
1 -Uniform (PSF)
0 to 14' 7" (Front)
9'
18.0
-
25.0
Residential - Living
Areas
Linked from: LVL
2 - Point (lb)
0 (Front)
N/A
201
316
-
BEAM (PT. 9),
Support 1
Notes
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported g
Page 11 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, 139
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
Overall Length: 11 1
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
2' 3"
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2778 @ 8' 8 1/4"
4648 (3.50")
Passed (60%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1321 @ 7' 5"
8571
Passed (15%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
3208 @ 4' 2 1/4"
21832
Passed (15%)
1.15
1.0 D + 1.0 S (Alt Spans)
Neg Moment (Ft-Ibs)
-1140 @ 8' 8 1/4"
16829
Passed (7%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.021 @ 4' 4 1/2"
0.284
Passed (U999+)
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.035 @ 4' 4 1/8"
0.426
Passed (U999+)
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 8' 7/16".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 3' 13/16".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.50"
703
958
1661
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
3.50"
2.09"
1205
1573
2778
Blocking
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
11' o/c
Bottom Edge (Lu)
11' o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 11' 1"
N/A
10.3
--
1 - Uniform (PSF)
0 to 11' 1" (Front)
9'
18.0
25.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/w(>odproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported1 0
Page 12 / 55
a" O R T CM MEMBER REPORT FAILED
UPPER FLOOR PLAN, B10
1 piece(s) 3 1/8" x 13 1/2" 24F-V4 DF Glulam
An excessive uplift of -1179 Ibs at support located at 11' 11" failed this product.
Overall Length: 12' 1"
6' 3"
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Y
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3926 @ 5' 4 3/4"
4648 (3.50")
Passed (84%)
--
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
2441 @ 4' 1 1/2"
8571
Passed (28%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
0 @ N/A
N/A
Passed (N/A)
--
N/A
Neg Moment (Ft-Ibs)
-8426 @ 5' 4 3/4"
16829
Passed (50%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl.(in)
0.136 @ 0
0.360
Passed (2L/950)
-
1.0 D + 1.0 S (Alt Spans)
Total Load Defl.(in)
0.238 @ 0
0.540
Passed (2L/544)
--
1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Left cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered.
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 11' 11".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
3.50"
2.96"
1720
2206
3926
Blocking
2 - Stud wall - SPF
3.50"
2.25"
1 1.50"
-478
-701
-1179
1 1/4" Rim Board
• lum boara is assumea to carry aii ioaas appiiea airectry above it, Dypassing the memoer Demg aesignea.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
12' o/c
Bottom Edge (Lu)
12' o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 11' 11 3/4"
N/A
10.3
--
1 - Uniform (PSF)
0 to 2' 3" (Front)
7'
18.0
25.0
Residential - Living
Areas
2 - Uniform (PSF)
2' 3" to 12' 1" (Front)
9"
18.0
25.0
Residential - Living
Areas
3 - Point (lb)
2' 3" (Front)
N/A
703
958
Linked from: B9,
Support 1
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
0
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
8/24/2020 4:49:18 PM UTC
ForteWEB v3.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported1 .�
Page 13 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, 1311
1 piece(s) 6 3/4" x 18" 24F-V4 DF Glulam
Overall Length: 27' a 1/2"
26 6' �
0 ❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
9239 @ 27' 1 1/2"
9872 (2.25")
Passed (94%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
8078 @ 2'
21465
Passed (38%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
61496 @ 13' 9"
66473
Passed (93%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.819 @ 13' 9"
0.892
Passed (L/392)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
1.341 @ 13' 9"
1.337
Passed (L/239)
1
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.91 that was calculated using length L = 26' 9".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Column - SPF
6.00"
4.75"
2.14"
3675
5775
9450
1 1/4" Rim Board
2 - Column - SPF
3.50"
2.25"
2.11"
3620
5688
9308
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
27' 1" o/c
Bottom Edge (Lu)
27' 1" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
1 1/4" to 272 1/4"
N/A
29.5
1 - Uniform (PSF)
0 to 27' 3 1/2" (Front)
7'
34.0
60.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported1 2
Page 25 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B12
1 piece(s) 5 1/8" x 15" 24F-V4 DF Glulam
Overall Length: I- I I
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
11411 @ 4"
14158 (4.25")
Passed (81%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
8922 @ 1' 8 1/2"
13581
Passed (66%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
39386 @ 7' 5 1/2"
38438
Passed (102%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.293 @ 75 1/2"
0.475
Passed (L/583)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.555 @ 75 1/2"
1 0.712
1 Passed (L/308)
1
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 14' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Column - SPF
5.50"
4.25"
3.43"
5455
6116
11571
1 1/4" Rim Board
2 - Column - SPF
5.50"
4.25"
3.43"
5455
6116
11571
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
6" o/c
Bottom Edge (Lu)
14' 9" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
1 1/4" to 14' 9 3/4"
N/A
18.7
1 - Uniform (PSF)
0 to 14' 11" (Front)
10'
34.0
40.0
Residential - Living
Areas
2 - Uniform (PSF)
0 to 14' 11" (Front)
7'
34.0
60.0
Residential - Living
Areas
3 - Uniform (PLF)
0 to 14' 11" (Front)
N/A
135.0
-
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported1 3
Page 26 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B13
1 piece(s) 5 1/8" x 16 1/2" 24F-V4 DF Glulam
Overall Length: 1�
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
10526 @ 4 1/2"
15823 (4.75")
Passed (67%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
8618 @ P 10 1/2"
17180
Passed (50%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
48613 @ 9' 10 1/2"
52330
Passed (93%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.472 @ 9' 10 1/2"
0.633
Passed (L/483)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.915 @ 9' 10 1/2"
0.950
Passed (L/249)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.98 that was calculated using length L = 19'.
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Column - SPF
6.00"
4.75"
3.16"
5143
5493
10636
1 1/4" Rim Board
2 - Column - SPF
6.00"
4.75"
3.16"
5143
5493
10636
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
19' 4" o/c
Bottom Edge (Lu)
19' 7" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 19' 7 3/4"
N/A
20.5
1 - Uniform (PSF)
0 to 19' 9" (Front)
22' 3"
18.0
25.0
Residential - Living
Areas
2 -Uniform (PLF)
0 to 19' 9" (Front)
N/A
100.0
Residential - LivingAreas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported1 4
Page 27 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B14
1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam
Overall Length: I- -
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
6377 @ 3 1/2"
6377 (1.91")
Passed (100%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
5474 @ 1' 3 1/2"
10865
Passed (50%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
22519 @ 74 1/4"
24600
Passed (92%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl.(in)
0.324 @ 74 1/4"
0.471
Passed (L/524)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.609 @ 74 1/4"
1 0.706
1 Passed (L/278)
1
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 14' 1 1/2".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
IF
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Hanger on SPF studWall
3.50"
Hanger'
1.91"
3106
3530
6636
See note 1
2 - Column - SPF
3.50"
2.25"
1.93"
3056
3470
6526
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
14' 2" o/c
Bottom Edge (Lu)
14' 2" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
1 - Top Mount Hanger
Connector not found
N/A
N/A
N/A
N/A
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead
Floor Live
Vertical Loads 10
Location (Side)
Tributary Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
3 1/2" to 14' 5 3/4"
N/A
14.9
--
1 - Uniform (PSF)
0 to 14' 7" (Front)
12'
34.0
40.0
Residential - Living
Areas
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported1 5
Page 28 / 55
a FORTE M3
MEMBER REPORT
MAIN FLOOR PLAN, B15
1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam
Overall Length: I- 1
14 3' L
1❑ 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
6387 @ 3 1/2"
6387 (1.92")
Passed (100%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
5491 @ 1' 3 1/2"
12495
Passed (44%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
22754 @ 75"
28290
Passed (80%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl.(in)
0.402 @ 7'5"
0.475
Passed (L/426)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.626 @ 7' 5"
0.712
Passed (L/273)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 14' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
vp
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Hanger on SPF studWall
3.50"
Hanger'
1.92"
2380
593
4265
7238
See note'
2 - Hanger on SPF studWall
3.50"
Hanger'
1.92"
2380
593
4265
7238
See note'
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
14' 3" o/c
Bottom Edge (Lu)
14' 3" o/c
-Maximum allowable bracing intervals based on applied load.
PASSED
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
1 - Top Mount Hanger
Connector not found
N/A
N/A
N/A
N/A
2 - Top Mount Hanger
Connector not found
N/A
N/A
N/A
N/A
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead
Floor Live
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
3 1/2" to 14' 6 1/2"
N/A
14.9
--
I - Uniform (PSF)
0 to 14' 10" (Front)
2'
34.0
40.0
-
Residential - Living
Areas
2 - Uniform (PSF)
0 to 14' 10" (Front)
5' 9"
18.0
100.0
Residential - Living
Areas
3 - Uniform (PLF)
0 to 14' 10" (Front)
N/A
135.0
-
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported1 6
Page 29 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B16
1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam
Overall Length:
4'
11 ❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1440 @ 2"
2988 (2.25")
Passed (48%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
658 @ 1' 3 1/2"
7619
Passed (9%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
1486 @ 2' 3 1/2"
17250
Passed (9%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.005 @ 2' 3 1/2"
0.142
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.006 @ 2' 3 1/2"
1 0.213
1 Passed (L/999+)
1
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 4' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.50"
247
1260
1507
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.50"
247
1260
1507
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
4' 5" o/c
Bottom Edge (Lu)
4' 5" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 4' 5 3/4"
N/A
9.1
1 - Uniform (PSF)
0 to 4' 7" (Front)
5' 6"
18.0
100.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported1 7
Page 31 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B17
1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam
Overall Length: 19' 10'
14' 3"
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
r
2' 6"
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1197 @ IT 2 1/4"
4648 (3.50")
Passed (26%)
1.0 D + 1.0 S (Adj Spans)
Shear (Ibs)
373 @ 16' 1/2"
5963
Passed (6%)
0.90
1.0 D (All Spans)
Pos Moment (Ft-Ibs)
1137 @ 9' 8 13/16"
13500
Passed (8%)
0.90
1.0 D (All Spans)
Neg Moment (Ft-Ibs)
-922 @ 172 1/4"
13297
Passed (7%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.016 @ 19' SO"
1 0.200
1 Passed (2L/999+)
I --
1.0 D + 1.0 S (Alt Spans)
Total Load Defl. (in)
0.049 @ 9' SO"
1 0.727
1 Passed (L/999+)
I --
1.0 D (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/0.2") and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 12' 4 7/8".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 5' 3/8".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
3.50"
1.50"
677
140
817
Blocking
2 - Stud wall - SPF
3.50"
3.50"
1 1.50"
839
358
1197
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
19' 10" o/c
Bottom Edge (Lu)
19' 10" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 19' 10"
N/A
9.1
1 - Uniform (PSF)
17' to 19' 10" (Front)
4' 9"
18.0
25.0
Residential - Living
Areas
2 - Uniform (PSF)
0 to 2' 6" (Front)
2' 3"
18.0
25.0
Residential - Living
Areas
3 - Uniform (PLF)
0 to 19' 10" (Front)
N/A
50.0
-
Notes
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported1 8
Page 32 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B18
1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam
Overall Length: 10' 11'
0 0
r
1I
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
6260 @ 10' 7"
17617 (5.50")
Passed (36%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
6238 @ 9' 5 1/2"
12495
Passed (50%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Pos Moment (Ft-Ibs)
19878 @ 53"
24600
Passed (81%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.119 @ 5' 7 1/2"
0.342
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
1 0.248 @ 5' 7 3/16"
1 0.512
1 Passed (L/495)
1
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 10' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Stud wall - DF
5.50"
4.25"
1.50"
2132
1951
562
4645
1 1/4" Rim Board
2 - Stud wall - DF
5.50"
5.50"
1.95"
3156
2142
1997
7295
Blocking
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 10" o/c
Bottom Edge (Lu)
10' 10" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 10' 11"
N/A
14.9
--
--
1 - Point (lb)
8' 4" (Front)
N/A
2046
593
2559
Linked from: B15,
Support 2
2 - Point (lb)
5' 3" (Front)
N/A
3080
3500
-
Linked from: B14,
Support 1
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
6/24/2021 3:07:39 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: UR801_Imported1 9
Page 1 / 1
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B19
1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam
Overall Length: 1� -
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3390 @ 2"
4901 (2.25")
Passed (69%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
2975 @ 1' 3 1/2"
10865
Passed (27%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
16210 @ 9' 9 1/2"
24600
Passed (66%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.581 @ 9' 9 1/2"
0.642
Passed (L/397)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.814 @ 9' 9 1/2"
1 0.962
1 Passed (L/284)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 19' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
2.25"
1.56"
977
2448
3425
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.56"
977
2448
3425
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
19' 5" o/c
Bottom Edge (Lu)
19' 5" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
1 1/4" to 19' 5 3/4"
N/A
14.9
1 - Uniform (PSF)
0 to 19' 7" (Front)
2' 6"
34.0
100.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported20
Page 35 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B20
1 piece(s) 8 3/4" x 12" 24F-V4 DF Glulam
Overall Length: 12' 9"
r
12
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
9635 @ 2"
19906 (3.50")
Passed (48%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
13590 @ 11' 3 1/2"
21333
Passed (64%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Pos Moment (Ft-Ibs)
46343 @ 73"
48300
Passed (96%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.241 @ 6' 6 3/8"
0.408
Passed (L/609)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.497 @ 6' 6 7/16"
1 0.613
1 Passed (L/296)
1
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 12' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IF
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Column Cap - steel
3.50"
3.50"
1.69"
4929
1736
4540
11205
Blocking
2 - Column Cap - steel
5.50"
5.50"
2.60"
7682
4468
5032
17182
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
12' 9" o/c
Bottom Edge (Lu)
12' 9" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 12' 9"
N/A
25.5
1 - Uniform (PSF)
0 to 12' 9" (Front)
22'
18.0
-
25.0
ROOF LOADS
2 - Point (lb)
7' 3" (Front)
N/A
2046
593
2559
Linked from: B15,
Support 1
3 - Point (lb)
T 3" (Front)
N/A
2110
2111
_
Linked from: B21,
Support 2
4 - Point (lb)
10' 4" (Front)
N/A
3080
3500
Linked from: 1314,
Support 1
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
6/24/2021 3:04:11 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser
File Name: UR801_Imported2 1
Page 1 / 1
a FORTE"M3
MEMBER REPORT
MAIN FLOOR PLAN, B21
1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam
PASSED
Overall Length: 13' 1 1/2"
I , i
13 L 19 3'
1❑ 0 ❑3
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
7388 @ IT 5 1/4"
7623 (3.50")
Passed (97%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
3683 @ 14' 7"
10865
Passed (34%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
11701 @ 24' 9 3/8"
24600
Passed (48%)
1.00
1.0 D + 1.0 L (Alt Spans)
Neg Moment (Ft-Ibs)
-13041 @ 13' 5 1/4"
18963
Passed (69%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.398 @ 23' 10 1/2"
1 0.651
1 Passed (L/589)
1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in)
0.530 @ 23' 11 9/16"
1 0.976
1 Passed (L/442)
1.0 D + 1.0 L (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 4 1/4".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 9' 5 3/16".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Total
Available
Required
Dead
Floor Live
Total
Supports
Accessories
1 - Stud wall - SPF
3.50"
2.25"
1.50"
398
1533/-508
1508
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
3.50"
3.39"
2110
5278
7388
None
3 - Stud wall - SPF
3.50"
2.25"
1.50"
800
2119/-88
2 19/
1 1/4" Rim Board
• Kim board Is assumed to carry all loads applied directly above It, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
32' 11" o/c
Bottom Edge (Lu)
32' 11" o/c
-Maximum allowable bracing intervals based on applied load.
1111111
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
1 1/4" to 33' 1/4"
N/A
14.9
1 - Uniform (PSF)
0 to 33' 1 1/2" (Front)
2' 6"
34.0
100.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes mmmmm====!
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported22
Page 38 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B22
1 piece(s) 6 3/4" x 12" 24F-V4 DF Glulam
Overall Length: 16' T
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
6643 @ 2"
9872 (2.25")
Passed (67%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
5596 @ 1' 3 1/2"
14310
Passed (39%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
25160 @ 79 1/2"
32339
Passed (78%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.325 @ 8' 3/4"
0.542
Passed (L/601)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.698 @ 8' 15/16"
0.813
Passed (L/279)
1
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Column - SPF
3.50"
2.25"
1.51"
3575
2893
1277
7745
1 1/4" Rim Board
2 - Column - SPF
3.50"
2.25"
1.50"
3021
2924
501
6446
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
16' 5" o/c
Bottom Edge (Lu)
16' 5" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
(1.15)
Comments wllllllllll
0 - Self Weight (PLF)
1 1/4" to 16' 5 3/4"
N/A
19.7
1 - Uniform (PSF)
0 to 16' 7" (Front)
8' 10 1/2"
34.0
40.0
-
Residential - Living
Areas
2 -Point (lb)
4' 9" (Front)
N/A
325
-
450
Residential - Living
Areas
3 - Point (lb)
4' 9" (Front)
N/A
945
-71
1328
Linked from: 68,
Support 2
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported23
Page 39 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B23
1 piece(s) 3 1/8" x 10 1/2" 24F-V4 DF Glulam
Overall Length: 9'
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
4777 @ 3"
6602 (3.25")
Passed (72%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
3144 @ P 3"
5797
Passed (54%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
10167 @ 4' 3"
13207
Passed (77%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.103 @ 4' 5 3/16"
0.283
Passed (L/987)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.228 @ 4' 5"
0.425
Passed (L/447)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 8' 6".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Column - SPF
4.50"
3.25"
2.35"
2748
1598
1252
5598
1 1/4" Rim Board
2 - Column - SPF
4.50"
3.25"
1.79"
2003
1598
663
4264
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
8' 10" o/c
Bottom Edge (Lu)
8' 10" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
(1.15)
Comments wllllllllll
0 - Self Weight (PLF)
1 1/4" to 8' 10 3/4"
N/A
8.0
1 - Uniform (PSF)
0 to 9' (Front)
8' 10 1/2"
34.0
40.0
-
Residential - Living
Areas
2 -Uniform (PSF)
0 to 4' 3" (Front)
9'
18.0
-
25.0
Residential - Living
Areas
3 - Uniform (PLF)
0 to 4' 3" (Front)
N/A
135.0
-
Residential - Living
Areas
4 - Point (lb)
4' 3" (Front)
N/A
703
958
Linked from: B9,
Support 1
user Notes
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/w(>odproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported24
Page 40 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B24
1 piece(s) 5 1/8" x 12" 24F-V4 DF Glulam
Overall Length: 13 1
9' 31,
❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
11660 @ 3' 2 1/2"
16656 (5.00")
Passed (70%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
4945 @ 4' 5"
10865
Passed (46%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
11891 @ 8' 4 1/16"
24600
Passed (48%)
1.00
1.0 D + 1.0 L (Alt Spans)
Neg Moment (Ft-Ibs)
-6177 @ T 2 1/2"
18963
Passed (33%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl.(in)
0.081 @ 8' 1/2"
0.319
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
Total Load Defl. (in)
0.161 @ 8' 1 11/1"6"
0.479
1 Passed (L/715)
1.0 D + 0.75 L + 0.75 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 8' 10 13/16".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 4' 3 3/8".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Column - SPF
5.00"
5.00"
3.50"
6490
3756
3137
13383
Blocking
2 - Column - SPF
5.00"
3.75"
1.90"
3455
2237/-190
1769
7190
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
13' o/c
Bottom Edge (Lu)
13' o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 12' 11 3/4"
N/A
14.9
1 - Uniform (PSF)
0 to 13' 1" (Front)
11'
34.0
40.0
_
Residential - Living
Areas
2 - Uniform (PSF)
0 to 13' 1" (Front)
13' 1 1/2"
18.0
28 0
Residential - Living
Areas
3 - Uniform (PLF)
0 to 13' 1" (Front)
N/A
135.0
-
Residential - Living
Areas
Weverhaeuser Notes
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator I Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported25
Page 41 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B25
1 piece(s) 6 3/4" x 16 1/2" 24F-V4 DF Glulam
Overall Length: 19' 10'
L 19 L
1I ❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
11521 @ 3 1/2"
16453 (3.75")
Passed (70%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
9539 @ 1' 9 1/2"
19676
Passed (48%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
54383 @ 9' 11"
58229
Passed (93%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.421 @ 9' 11"
0.642
Passed (L/548)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.798 @ 9' 11"
1 0.962
1 Passed (L/290)
1
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.95 that was calculated using length L = 19' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Column - SPF
5.00"
3.75"
2.63"
5492
6148
11640
1 1/4" Rim Board
2 - Column - SPF
5.00"
3.75"
2.63"
5492
6148
11640
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
19' 8" o/c
Bottom Edge (Lu)
19' 8" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
1 1/4" to 19' 8 3/4"
N/A
27.1
1 - Uniform (PSF)
0 to 19' 10" (Front)
15' 6"
34.0
40.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported26
Page 42 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B26
1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam
Overall Length:7' a 1/2"
M9
6' 3"
1I ❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
4711 @ 6' 10"
7637 (5.75")
Passed (62%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear(lbs)
2778 @ 1'5 1/2"
7619
Passed (36%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Pos Moment (Ft-Ibs)
6903 @ 3' 7"
17250
Passed (40%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl.(in)
0.036 @ 3'7"
0.217
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.065 @ 3' 7"
0.325
Passed (L/999+)
1
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 6' 6".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Column - SPF
5.50"
4.25"
2.24"
2103
1433
2007
5543
1 1/4" Rim Board
2 - Stud wall - SPF
7.00"
5.75"
3.55"
2176
1483
2077
5736
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
7' 1" o/c
Bottom Edge (Lu)
7' 1" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 7' 2 1/4"
N/A
9.1
1 - Uniform (PSF)
0 to 7' 3 1/2" (Front)
10'
34.0
40.0
-
Residential - Living
Areas
2 - Uniform (PSF)
0 to 7' 3 1/2" (Front)
7'
34.0
80.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported27
Page 43 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B27
1 piece(s) 6 3/4" x 18" 24F-V4 DF Glulam
Overall Length: 27 1'
26 6' �
11 ❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
9239 @ 2"
9872 (2.25")
Passed (94%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
8078 @ 1' 9 1/2"
21465
Passed (38%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
61496 @ 13' 6 1/2"
66473
Passed (93%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.819 @ 13' 6 1/2"
0.892
Passed (L/392)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
1.341 @ 13' 6 1/2"
1 1.337
1 Passed (L/239)
1
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.91 that was calculated using length L = 26' 9".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Column - SPF
3.50"
2.25"
2.11"
3620
5688
9308
1 1/4" Rim Board
2 - Column - SPF
3.50"
2.25"
2.11"
3620
5688
9308
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
26' 11" o/c
Bottom Edge (Lu)
26' 11" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
1 1/4" to 26 11 3/4"
N/A
29.5
1 -Uniform (PSF)
0 to 27' 1" (Front)
7'
34.0
60.0
Residential - LivingAreas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported28
Page 44 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B28
1 piece(s) 5 1/8" x 15" 24F-V4 DF Glulam
Overall Length: 18' 5'
L 17' 6" L
1I ❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
6161 @ 4"
9257 (4.25")
Passed (67%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
5075 @ 1' 8 1/2"
15618
Passed (32%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
26650 @ 9' 2 1/2"
43961
Passed (61%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.362 @ 9' 2 1/2"
0.592
Passed (L/589)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.583 @ 9' 2 1/2"
1 0.887
1 Passed (L/366)
1
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.99 that was calculated using length L = 17' 9".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
5.50"
4.25"
2.83"
2362
3868
6230
1 1/4" Rim Board
2 - Stud wall - SPF
5.50"
4.25"
2.83"
2362
3868
6230
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
18' 3" o/c
Bottom Edge (Lu)
18' 3" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 18' 3 3/4"
N/A
18.7
1 -Uniform (PSF)
0 to 18' S" (Front)
7'
34.0
60.0
Residential - LivingAreas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported29
Page 45 / 55
a" O R T CM MEMBER REPORT PASSED
MAIN FLOOR PLAN, B29
1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam
Overall Length: 1 10'
11 ❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2116 @ 2"
4570 (2.25")
Passed (46%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
1747 @ 1' 3 1/2"
6625
Passed (26%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
7076 @ 6' 11"
15000
Passed (47%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.208 @ 6' 11"
0.450
Passed (L/780)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.287 @ 6' 11"
1 0.675
1 Passed (L/565)
1
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 13' 6".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Column - SPF
3.50"
2.25"
1.50"
591
1556
2147
1 1/4" Rim Board
2 - Column - SPF
3.50"
2.25"
1.50"
591
1556
2147
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
13' 8" o/c
Bottom Edge (Lu)
13' 8" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
1 1/4" to IT 8 3/4"
N/A
9.1
1 - Uniform (PSF)
0 to 13' 10" (Front)
2' 3"
34.0
100.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported30
Page 46 / 55
a" O R T CM MEMBER REPORT PASSED
BASEMENT FLOOR PLAN, B30
1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam
Overall Length: 1'
7' 6" L
11 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2658 @ 2"
2988 (2.25")
Passed (89%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
1857 @ 1' 3 1/2"
6625
Passed (28%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
5069 @ 4' 1/2"
15000
Passed (34%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.036 @ 4' 1/2"
0.258
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.068 @ 4' 1/2"
1 0.387
1 Passed (L/999+)
1
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 7' 9".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
2.25"
2.00"
1273
1455
2728
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
2.00"
1273
1455
2728
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
7' 11" o/c
Bottom Edge (Lu)
7' 11" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
1 1/4" to 7' 11 3/4"
N/A
9.1
1 -Uniform (PSF)
0 to 8' 1" (Front)
9'
34.0
40.0
Residential - LivingAreas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported31
Page 48 / 55
a FORTE M3
MEMBER REPORT
BASEMENT FLOOR PLAN, B31
1 piece(s) 5 1/8" x 16 1/2" 24F-V4 DF Glulam
PASSED
Overall Length: 1 T 112'
16' 3"
1❑ 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
15204 @ 3 1/2"
15204 (4.56")
Passed (100%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
11314 @ 1' 8"
14939
Passed (76%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
46600 @ 8' 5"
46186
Passed (SOS%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.396 @ 8' 5 5/16"
0.546
Passed (L/496)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.772 @ 8' 5 3/16"
1 0.819
1 Passed (L/255)
1
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.99 that was calculated using length L = 16' 4 1/2".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
IF
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Hanger on SPF studWall
3.50"
Hanger'
4.56"
7718
6175
4477
18370
See note 1
2 - Column - SPF
6.00"
4.75"
4.23"
6871
6156
3591
16618
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• 1 See Connector grid below for additional information and/or requirements.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
4' 4" o/c
Bottom Edge (Lu)
168" o/c
-Maximum allowable bracing intervals based on applied load.
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Connector: Simpson Strong -Tie
Support
Model
Seat Length
Top Fasteners
Face Fasteners
Member Fasteners
Accessories
1 - Top Mount Hanger
Connector not found
I N/A
N/A
N/A
N/A
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported32
Page 49 / 55
a" O R T CM MEMBER REPORT PASSED
BASEMENT FLOOR PLAN, B32
1 piece(s) 6 3/4" x 15" 24F-V4 DF Glulam
Overall Length: 24' 9 1 j2'
0-
2. 3" 21' 9" L
0 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
13382 @ 2' 6"
17213 (6.00")
Passed (78%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
11777 @ 4'
17888
Passed (66%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
44052 @ 6' 3"
47914
Passed (92%)
1.00
1.0 D + 1.0 L (All Spans)
Neg Moment (Ft-Ibs)
-77 @ 2' 6"
35121
Passed (0%)
0.90
1.0 D (All Spans)
Live Load Defl. (in)
0.455 @ 12' 5/8"
1 0.738
1 Passed (L/583)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.932 @ 12' 1 7/16"
1 1.106
1 Passed (L/285)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240). Upward deflection on left cantilever exceeds overhang deflection criteria.
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.95 that was calculated using length L = 22' 1 7/16".
• Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 2' 6 1/8".
• Upward deflection on left cantilever exceeds 0.4".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Beam - SPF
6.00"
6.00"
4.66"
6747
5128
3718
15593
Blocking
2 - Plate on concrete - SPF
3.50"
2.25"
1.50"
1578
1047
759
3384
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
24' 8" o/c
Bottom Edge (Lu)
24' 8" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 24' 8 1/4"
N/A
24.6
1 - Point (lb)
6' 3" (Front)
N/A
7718
6175
4477
Linked from: 631,
Support 1
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/wGodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported33
Page 51 / 55
a" O R T CM MEMBER REPORT PASSED
BASEMENT FLOOR PLAN, B33
1 piece(s) 6 3/4" x 19 1/2" 24F-V4 DF Glulam
Overall Length: 1= 11
6 M9
t 13 9' L
❑z
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
20539 @ 14' 5 1/2"
25228 (5.75")
Passed (81%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
17978 @ 12' 8 1/2"
23254
Passed (77%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
73562 @ 7191,
82569
Passed (89%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl.(in)
0.160 @ 7'9 1/4"
0.467
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.343 @ 79"
0.700
Passed (L/490)
1
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 0.97 that was calculated using length L = 14'.
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Snow
Total
1 - Column - PSL
7.00"
5.75"
3.13"
7452
5953
2488
15893
1 1/4" Rim Board
2 - Column - PSL
7.00"
5.75"
4.68"
10568
7656
5687
23911
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
14' 9" o/c
Bottom Edge (Lu)
14' 9" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
(1.15)
Comments wllllllllll
0 - Self Weight (PLF)
1 1/4" to 14' 9 3/4"
N/A
32.0
1 - Uniform (PSF)
0 to 11' 3" (Front)
10' 6"
34.0
40.0
-
Residential - Living
Areas
2 - Uniform (PSF)
11' 3" to 14' 11" (Front)
4' 6"
15.0
80.0
Residential - Living
Areas
3 - Point (lb)
7' 9" (Front)
N/A
6490
3756
3137
Linked from: 624,
Support 1
4 - Point (lb)
11' 3" (Front)
N/A
6747
5128
3718
Linked from: B32,
Support 1
user Notes
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/w(>odproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported34
Page 52 / 55
a" O R T CM MEMBER REPORT PASSED
BASEMENT FLOOR PLAN, B34
1 piece(s) 3 1/8" x 12" 24F-V4 DF Glulam
Overall Length: 7 1'
6' 6" L
11 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1171 @ 2"
2988 (2.25")
Passed (39%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
766 @ 1' 3 1/2"
7619
Passed (10%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
1940 @ 3' 6 1/2"
17250
Passed (11%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.015 @ T 6 1/2"
0.225
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.020 @ T 6 1/2"
0.338
Passed (L/999+)
1
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 6' 9".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.50"
302
903
1205
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.50"
302
903
1205
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
6' 11" o/c
Bottom Edge (Lu)
6' 11" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 6' 11 3/4"
N/A
9.1
1 - Uniform (PSF)
0 to 7' 1" (Front)
4' 3"
18.0
60.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported35
Page 53 / 55
a" O R T CM MEMBER REPORT PASSED
BASEMENT FLOOR PLAN, B35
1 piece(s) 5 1/8" x 9" 24F-V4 DF Glulam
Overall Length: 17 1'
16 6' L
11 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2276 @ 2"
4901 (2.25")
Passed (46%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
2023 @ 1' 1/2"
9371
Passed (22%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
9459 @ 8' 6 1/2"
15913
Passed (59%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.521 @ 8' 6 1/2"
0.558
Passed (L/385)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.852 @ 8' 6 1/2"
1 0.837
1 Passed (L/236)
1
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 9".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.50"
893
1409
2302
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.50"
893
1409
2302
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
16' 11" o/c
Bottom Edge (Lu)
16' 11" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 16 11 3/4"
N/A
11.2
1 - Uniform (PSF)
0 to 17' 1" (Front)
2' 9"
34.0
60.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported36
Page 54 / 55
a" O R T CM MEMBER REPORT PASSED
BASEMENT FLOOR PLAN, B36
1 piece(s) 3 1/8" x 9" 24F-V4 DF Glulam
Overall Length: 14' a'
11 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1708 @ 2"
2988 (2.25")
Passed (57%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1481 @ 1' 1/2"
5714
Passed (26%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
5925 @ 7' 2"
9703
Passed (61%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.379 @ 7' 2"
0.467
Passed (L/443)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.612 @ 72"
0.700
Passed (L/275)
1
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 14'.
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports IV
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.50"
657
1075
1732
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1.50"
657
1075
1732
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
14' 2" o/c
Bottom Edge (Lu)
14' 2" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 14' 2 3/4"
N/A
6.8
1 - Uniform (PSF)
0 to 14' 4" (Front)
2' 6"
34.0
60.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported37
Page 55 / 55
a FORTE'M3
MEMBER REPORT
UPPER FLOOR PLAN, H1
2 piece(s) 2 x 10 Douglas Fir -Larch No. 1
PASSED
1
a
0
Overall Length:
5'
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Y
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1550 @ 2"
2869 (2.25")
Passed (54%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
997 @ 1' 3/4"
3830
Passed (26%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
1987 @ 2' 9 1/2"
4510
Passed (44%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.017 @ 2' 9 1/2"
0.175
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.029 @ 2' 9 1/2"
0.262
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.50"
685
925
1610
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1 1.50"
685
925
1610
1 1/4" Rim Board
• Kim boaro is assumes to carry aii ioaas appuea oirectiy anove it, Dypassmg the memner Demg aesignea.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 5" o/c
Bottom Edge (Lu)
5' 5" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 5' 5 3/4"
N/A
7.0
1 - Uniform (PSF)
0 to 5' 7" (Front)
IT 3"
18.0
25.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported38
Page 15 / 55
a FORTE'M3
MEMBER REPORT
UPPER FLOOR PLAN, H2
2 piece(s) 2 x 10 Douglas Fir -Larch No. 1
PASSED
1
a
0
Overall Length: 3
8'
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Y
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1515 @ 2"
2869 (2.25")
Passed (53%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1168 @ 1' 3/4"
3830
Passed (31%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
3078 @ 4' 3 1/2"
4510
Passed (68%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.064 @ 4' 3 1/2"
0.275
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.112 @ 4' 3 1/2"
0.412
Passed (L/883)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.50"
667
885
1552
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1 1.50"
667
885
1552
1 1/4" Rim Board
• Kim boaro is assumes to carry aii ioaas appuea oirectiy anove it, Dypassmg the memner Demg aesignea.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
8' 5" o/c
Bottom Edge (Lu)
8' 5" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
1 1/4" to 8' 5 3/4"
N/A
7.0
1 - Uniform (PSF)
0 to 8' 7" (Front)
8' 3"
18.0
25.0
Residential - Living
Areas
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASO
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported39
Page 16 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, RI
1 piece(s) 14" TJI@ 560 @ 12" OC
Overall Length: 2 10"
11 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
551 @ 2 1/2"
1606 (2.25")
Passed (34%)
1.15
1.0 D + 1.0 S (All Spans)
Shear(lbs)
543 @ 3 1/2"
2749
Passed (20%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
3472 @ 12' 11"
12966
Passed (27%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.257 @ 12' 11"
0.847
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.442 @ 12' 11"
1 1.271
1 Passed (L/690)
1.0 D + 1.0 S (All Spans)
TI-ProTm Rating
42
1 40
1 Passed
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge' Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProT" Rating include: 5/8" Gypsum ceiling, bridging or blocking at max. 8' o.c..
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.75"
233
323
556
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1 1.75"
233
323
556
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 6" o/c
Bottom Edge (Lu)
25' 8" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Load
Location (Side)
Spacing
(0.90)
(1.15)
Comments
1 - Uniform (PSF)
0 to 25' 10"
12"
18.0
25.0
Residential - Living
Areas
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported40
Page 17 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, R2
1 piece(s) 14" TJI@ 560 @ 16" OC
Overall Length: 22' a'
11 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
634 @ 2 1/2"
1606 (2.25")
Passed (39%)
1.15
1.0 D + 1.0 S (All Spans)
Shear(lbs)
624 @ 3 1/2"
2749
Passed (23%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
3442 @ 11' 2"
12966
Passed (27%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.192 @ 11' 2"
0.731
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.330 @ 11' 2"
1.096
1 Passed (L/796)
1.0 D + 1.0 S (All Spans)
TI-ProTm Rating
48
40
1 Passed
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge' Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProT" Rating include: 5/8" Gypsum ceiling.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.75"
268
372
640
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1 1.75"
268
372
640
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
10' 7" o/c
Bottom Edge (Lu)
22' 2" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Load
Location (Side)
Spacing
(0.90)
(1.15)
Comments
1 - Uniform (PSF)
0 to 22' 4"
16"
18.0
25.0
Residential - Living
Areas
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported41
Page 18 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, R3
1 piece(s) 14" TJI@ 230 @ 16" OC
Overall Length: 20' 1'
19 6' L
11 0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
570 @ 2 1/2"
1360 (2.25")
Passed (42%)
1.15
1.0 D + 1.0 S (All Spans)
Shear(lbs)
559 @ 3 1/2"
2237
Passed (25%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
2772 @ 10' 1/2"
5739
Passed (48%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.208 @ 10' 1/2"
0.656
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.358 @ 10' 1/2"
1 0.983
1 Passed (L/660)
1.0 D + 1.0 S (All Spans)
TI-ProTm Rating
47
1 40
1 Passed
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge' Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProT" Rating include: 5/8" Gypsum ceiling.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - SPF
3.50"
2.25"
1.75"
241
335
576
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1 1.75"
241
335
576
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 8" o/c
Bottom Edge (Lu)
19' 11" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Load
Location (Side)
Spacing
(0.90)
(1.15)
Comments
1 - Uniform (PSF)
0 to 20' 1"
16"
18.0
25.0
Residential - Living
Areas
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported42
Page 19 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, J1
1 piece(s) it 7/8" TJI@ 560 @ 16" OC
Overall Length: 20' 1'
19 6' �
11 ❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
981 @ 2 1/2"
1396 (2.25")
Passed (70%)
1.00
1.0 D + 1.0 L (All Spans)
Shear(lbs)
962 @ 3 1/2"
2050
Passed (47%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
4770 @ 10' 1/2"
9500
Passed (50%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.289 @ 10' 1/2"
0.656
Passed (L/818)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.534 @ 10' 1/2"
1 0.983
1 Passed (L/442)
1
1.0 D + 1.0 L (All Spans)
TJ-ProTm Rating
49
1 40
1 Passed
I
--
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge' Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProT" Rating include: 5/8" Gypsum ceiling.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
2.25"
1.75"
455
536
991
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1 1.75"
455
536
991
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
8' 1" o/c
Bottom Edge (Lu)
19' 11" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Load
Location (Side)
Spacing
(0.90)
(1.00)
Comments
1 - Uniform (PSF)
0 to 20' 1"
16"
34.0
40.0
Residential - Living
Areas
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported43
Page 20 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, J2
1 piece(s) it 7/8" TJI@ 230 @ 16" OC
Overall Length: 1u' a'
17 9' �
11 ❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
894 @ 2 1/2"
1183 (2.25")
Passed (76%)
1.00
1.0 D + 1.0 L (All Spans)
Shear(lbs)
876 @ 3 1/2"
1655
Passed (53%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
3959 @ 9' 2"
4215
Passed (94%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.332 @ 9' 2"
0.597
Passed (L/648)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.614 @ 9' 2"
0.896
1 Passed (L/350)
1.0 D + 1.0 L (All Spans)
TJ-Pro'"" Rating
46
40
1 Passed
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeTM Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-ProTM Rating include: 5/8" Gypsum ceiling.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
2.25"
1.75"
416
489
905
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1 1.75"
416
489
905
1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
4' 1" o/c
Bottom Edge (Lu)
18' 2" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Load
Location (Side)
Spacing
(0.90)
(1.00)
Comments
1 - Uniform (PSF)
0 to 18' 4"
16"
34.0
40.0
Residential - Living
Areas
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported44
Page 21 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, J3
1 piece(s) 2 x 10 Douglas Fir -Larch No. 1 @ 12" OC
Overall Length:
11 ❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
253 @ 2 1/2"
1434 (2.25")
Passed (18%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
163 @ 1' 3/4"
1665
Passed (10%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
314 @ 2' 9 1/2"
2255
Passed (14%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.006 @ 2' 9 1/2"
0.172
Passed (L/999+)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.009 @ 2' 9 1/2"
1 0.258
1 Passed (L/999+)
1.0 D + 1.0 L (All Spans)
TJ-Pro'"" Rating
N/A
I N/A
I N/A
N/A
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based on NDS.
• No composite action between deck and joist was considered in analysis.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
2.25"
1.50"
95
167
262
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1 1.50"
95
167
262
1 1/4" Rim Board
• Kim boara is assumea to carry au ioaas appiiea airectry aoove it, Dypassing me memoer Demg aesignea.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
5' 5" o/c
Bottom Edge (Lu)
5' 5" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Load
Location (Side)
Spacing
(0.90)
(1.00)
Comments
1 - Uniform (PSF)
0 to 5' 7"
12"
34.0
60.0
Residential - Living
Areas
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
,vww.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported45
Page 22 / 55
a" O R T CM MEMBER REPORT PASSED
UPPER FLOOR PLAN, J4
2 piece(s) 2 x 10 Douglas Fir -Larch No. 1 @ 16" OC
Overall Length: 11'
14'
11 ❑2
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
901 @ 2 1/2"
2869 (2.25")
Passed (31%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
781 @ 1' 3/4"
3330
Passed (23%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
3144 @ 7' 3 1/2"
4510
Passed (70%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.216 @ 7' 3 1/2"
0.472
Passed (L/789)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.338 @ 73 1/2"
1 0.708
1 Passed (L/503)
1.0 D + 1.0 L (All Spans)
TJ-Pro'"" Rating
N/A
I N/A
I N/A
N/A
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based on NDS.
• No composite action between deck and joist was considered in analysis.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stud wall - SPF
3.50"
2.25"
1.50"
331
583
914
1 1/4" Rim Board
2 - Stud wall - SPF
3.50"
2.25"
1 1.50"
331
583
914
1 1/4" Rim Board
• Kim boara is assumea to carry au ioaas appiiea airectry aoove it, Dypassing me memoer Demg aesignea.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
1T 3" o/c
Bottom Edge (Lu)
14' 5" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Load
Location (Side)
Spacing
(0.90)
(1.00)
Comments
1 - Uniform (PSF)
0 to 14' 7"
16"
34.0
60.0
Residential - Living
Areas
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
,vww.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
JATIN SINGLA
MAINLAND ENGINEERING
(604) 126-4545
ajitstr8@gmail.com
8/24/2020 4:49:18 PM UTC
ForteWEB 0.0, Engine: V8.1.3.1, Data: V8.0.0.0
Weyerhaeuser File Name: UR801_Imported46
Page 23 / 55
Title Block Line 1
You can change this area
using the "Settings" menu item
and then using the "Printing &
Title Block" selection.
Title Block Line 6
Project Title: 801
Engineer:
Project ID:
Printed: 19 AUG 2020, 6:16AM
ASCE Seismic Base Shear File=C:lUsersIGLIRJIN-11DesktoplBASEPLATE WITH MOMENT -Copy.ec6 .
Software copyright ENERCALC, INC.1983-2019, Build:12.19.11.30 .
0.0r rr MAINLAND ENGINEERING CONSULTANTS•• •• •
Risk Category
Calculations per ASCE 7-10
Risk Category of Building or Other Structure : "II" : All Buildings and other structures
except those listed as Category I, III, and IV
ASCE 7-10, Page 2, Table 1.5-1
Seismic Importance Factor =
1
ASCE 7-10, Page 5, Table 1.5-2
USER DEFINED Ground Motion
ASCE 7-10 11.4.1
Max. Ground Motions, 5% Damping:
SS = 1.330 g, 0.2 sec response
S 1 = 0.520 g, 1.0 sec response
Site Class, Site Coeff. and Design Category
Site Classification "D" :Shear Wave Velocity 600 to 1,200 ft/sec
= D
ASCE 7-10 Table 20.3-1
Site Coefficients Fa & Fv
Fa
= 1.00
ASCE 7-10 Table 11.4-1 & 11.4-2
(using straight-line interpolation from table values)
Fv
= 1.50
Maximum Considered Earthquake Acceleration
S MS = Fa * Ss
= 1.330
ASCE 7-10 Eq. 11.4-1
S M1 = Fv * S1
= 0.780
ASCE 7-10 Eq. 11.4-2
Design Spectral Acceleration
S DS S MS2/3
= 0.887
ASCE 7-10 Eq. 11.4-3
S D1 S M12/3
= 0.520
ASCE7-10 Eq. 11.4-4
Seismic Design Category
= D
ASCE 7-10 Table 11.6-1 & -2
Resistina Svstem
ASCE 7-10 Table 12.2-1
Basic Seismic Force Resisting System ...
Bearing Wall Systems
13.1-ight-frame (wood) walls sheathed wlwood structural
panels rated for shear resistance.
Response Modification Coefficient " R "
= 6.50
Building height Limits:
System Overstrength Factor " Wo "
= 2.50
Category "A & B" Limit:
No Limit
Deflection Amplification Factor " Cd "
= 4.00
Category "C" Limit:
Category "D" Limit:
No Limit
Limit = 65
NOTE! See ASCE 7-10 for all applicable footnotes.
Category "E" Limit:
Limit = 65
Category "F" Limit:
Limit = 65
Lateral Force Procedure
ASCE7-10 Section 12.8.2
Equivalent Lateral Force Procedure
The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE 7-1012.8
Determine Building Period
Use ASCE 12.8-7
Structure Type for Building Period Calculation : All Other Structural Systems
" Ct " value = 0.020 " hn " : Height from base to highest level = 28.0 ft
"x"value = 0.75
" Ta " Approximate fundemental period using Eq. 12.8-7 : Ta = Ct * (hn ^ x) = 0.243 sec
"TL" : Long -period transition period per ASCE 7-10 Maps 22-12 > 22-16 8.000 sec
Building Period " Ta " Calculated from Approximate Method selected
= 0.243 sec
Cs " Response Coefficient
ASCE 7-10 Section 12.8.1.1
S DS: Short Period Design Spectral Response = 0.887 From Eq. 12.8-2, Preliminary Cs
= 0.136
" R " : Response Modification Factor = 6.50 From Eq.12.8-3 & 12.8-4 , Cs need not exceed
= 0.329
" I " : Seismic Importance Factor = 1 From Eq.12.8-5 & 12.8-6, Cs not be less than
= 0.039
Cs :Seismic Response Coefficient =
= 0.1364
Seismic Base Shear
ASCE 7-10 Section 12.8.1
Cs = 0.1364 from 12.8.1.1
W ( see Sum Wi below) = 384.30 k
Seismic Base Shear V = Cs * W = 52.42 k
M
MAINLAND ENGG. CONSULTANTS CORPORATION
Project:
SINGLE FAMILY DWELLING
Sheet
Location:
115712 - 72 AVE. WEST,EDMONDS WA
Job No.:
JUR801
Date:
20-Aug-20
By:
JBS
Chk:
JAB
SEISMIC ANALYSIS (BUILDING)
DEAD WEIGHT OF ROOF =
18
# /SQ. FT.
DEAD WEIGHT OF FLOOR =
36
# /SQ. FT.
AVG. WEIGHT OF WALLS =
12.5
# /SQ. FT.
AREA OF ROOF =
3010
SQ FT.
AREA OF UPPER FLOOR =
2390
SQ FT.
AREA OF MAIN FLOOR =
3690
SQ FT.
PARAPET WALL LENGTH AT ABOVE ROOF
= 0.25
FT.
TOTAL AVG. WALL LENGTH AT EACH FLOOR
= 450
FT.
HEIGHT OF WALLS UNDER ROOF FRAMING
= 9
FT.
HEIGHT OF WALLS UNDER UPPER FLOOR FRAMING
= 9
FT.
HEIGHT OF WALLS UNDER MAIN FLOOR FRAMING
= 9
FT.
HEIGHT OF PARAPET (AVEGAGE)
= 0
FT.
BUILDING WEIGHT:
WT. OF MAIN ROOF (1/2 OF WALL HT.+PARAPET)
= 79492.5
#
WT. OF UPPER FLOOR AND WALLS(1/2UPPER+1/2 BELOW HEIGHT) _
= 136665
#
WT. OF MAIN FLOOR AND WALLS(1/2UPPER+1/2 BELOW HEIGHT) _
= 183465
#
TOTAL WEIGHT OF BUILDING (W)
= 399622.5
#
DESIGN BASE SHEAR SEE NEXT PAGE (EQUIVALENT LATERAL FORCE PROCEDURE)
V = 0.1364 x W = 0.1364 x 399622.500
= 54509
# (SD)
= 38156
# (ASD)
DISTRIBUTION OF SEISMIC FORCES
LEVEL
HT. OF
STORY "H"
WEIGHT OF
STORY "W"
W x H
# FT.
FORCE (#) _
[(WxH)xV]/(TOTAL W xH)
FORCE
(PSF)
FORCE
(PSF)
SD
ASD
ROOF
30.25
79492.5
2404648.125
18798
6.2
3.75
UPPER FLOOR
20
1136665
2733300
21368
8.9
5.36
MAIN FLOOR
10
183465
1834650
14342
3.9
2.33
TOTAL =
399622.5
1
16972598.125
154508.5
119.1
111.44
48
Title Block Line 1
You can change this area
using the "Settings" menu item
and then using the "Printing &
Title Block" selection.
Title Block Line 6
Project Title: 801
Engineer:
Project ID:
57
Printed: 20 AUG 2020, 9:33PM
ASCE 7-10 Wind Forces Ch t 28, Pt2 & Ch t 30, Pt2 File=CALC,INC.1983-202 ,Buil1UR80.2.24 .
p p Software copyright ENERCALC, INC.1983-2020, BuiId:12.20.2.24 .
CORPORATION
DESCRIPTION: --None--
Analytical Values Calculations per ASCE 7-10
V : Basic Wind Speed per Sect 26.5-1 A, B or C 110.0 mph
Roof Slope Angle 0 to 5 degrees
Occupancy per Table 1.5-1 11 All Buildings and other structures except
those listed as Category I, III, and IV
Exposure Category per 26.7
Exposure D
MRH : Mean Roof Height
30.250 ft
Lambda: per Figure 28.6-1, Page 305
1.70
Effective Wind Area of Component & Cladding
10.0 ft^2
Roof pitch for cladding pressure
0 to 7 degrees
User specified minimum design pressure
10.0 psf
Topographic Factor Kzt per 26.8
1.00
LHD : Least Horizontal Dimension
30.0 ft
a = max (0.04 * LHD, 3, min(0.10 * LHD, 0.4*MRH))
3.00 ft
max (0.04 * LHD, 3, min(0.10 * LHD, 0.4*MRH))
Design Wind Pressures
Horizontal Pressures ...
Zone: A =
32.64 psf
Zone: C =
21.59 psf
Zone: B =
-17.00 psf
Zone: D =
-10.03 psf
Vertical Pressures ...
Zone: E =
-39.27 psf
Zone: G =
-27.20 psf
Zone: F =
-22.27 psf
Zone: H =
-17.17 psf
Overhangs...
Zone: Eoh =
-54.91 psf
Zone: Goh =
-43.01 psf
ASCE 7-10 Section 28.6.4 Minimum Design Wind Loads requires that the load effects of the design wind
pressures from Section 28.6.3 shall not be less than a minimum load defined by assuming the pressures, ps, for
zones A and C equal to +16 psf, Zones B and D equal to +8 psf, while assuming ps for Zones E, F, G, and H are
equal to 0 psf.
)mponent & Cladding Design Wind Pressures
Design Wind Pressure = Lambda * Kzt * Ps30 per Eq 30.5-1
Roof Zone 1 :
Positive :
15.130 psf
Negative:
-37.060 psf
Roof Zone 2 :
Positive :
15.130 psf
Negative :
-62.050 psf
Roof Zone 3 :
Positive :
15.130 psf
Negative:
-93.500 psf
Wall Zone 4 :
Positive :
37.060 psf
Negative :
-40.120 psf
Wall Zone 5 :
Positive :
37.060 psf
Negative:
-49.470 psf
Roof Overhang Zone 2:
-53.380 psf
Roof Overhang Zone 3:
-87.720 psf
me
MAINLAND ENGG. CONSULTANTS CORPORATION
Project: SINGLE FAMILY DWELLING Sheet
Location: 115712 - 72 AVE. WEST,EDMONDS WA Job No.: JUR801
Date: 20-Aua-20 Bv: lis Chk: IAB
HORIZONTAL WIND FORCE:
HORZ. WIND PRESSURE (ZONE A)
HORZ. WIND PRESSURE (ZONE C)
BUILDING LENGTH =
96.5 FT.
BUILDING WIDTH =
51.5 FT.
MEAN ROOF HEIGHT =
30.25 FT.
AVG. PARAPET HEIGHT =
0.25 FT.
a =
3 FT.
PARAPET WIND PRESSURE = 2.25' WALL PRESSURE
WIND FORCES AT EACH STORY (ASD)
32.64 PSF = 19.58 PSF (ASD)
21.59 PSF = 12.95 PSF (ASD)
(SEE WIND ANALYSIS PAGE)
DESG.
PARAPET
WIND (PSF)
PARAPET
HEIGHT
INT. WALL
WIND(PSF)
END WALL
WIND(PSF)
WALL TRIB.
HEIGHT
WIND(PLF)
WIND(PLF)
WIND
INT. ZONE
END ZONE
UPWARD (P£
ROOF
29.1465
0.25
12.95
19.58
5.75
82
120
-17.77
UPPER FLOOR
12.95
19.58
10.00
130
196
MAIN FLOOR
12.95
19.58
10.00
130
196
F)
50
MAINLAND ENGG. CONSULTANTS CORPORATION
Project:
SINGLE FAMILY DWELLING
Sheet
Location:
15712 - 72 AVE. WEST,EDMONDS WA
Job No.:
UR801
Date:
25-Aug-20
By:
JS
Chk:
AB
ROOF SEISMIC FORCE (SF) = 3.8 #/SQ FT. (ASD)
LATERAL ANALYSIS (ALONG GRID #1 TO #7) WIND FORCE (WF) = 82 PLF (INTERIOR ZONE)
120 PLF (END ZONE)
END ZONE
INTERIOR ZONE
END ZONE
SHEAR LINE
2
3
4
5
616.1
7
TRIB. WALL LENGTH FOR WIND FORCES ='B' ft
3.8
9.8
8.3
5.3
6.8
3.8
WIND SHEAR FORCE = B*WF
450
1169
675
433
809
450
TRIB. SEISMIC AREA = 'A' SQ.FT=
348
828
744
484
548
156
SEISMIC SHEAR FORCE 'V' = A*SF
1305
3105
2790
1815
2055
585
GOVERNING LOAD (W (wind) or E (Seismic)
SEISMIC
SEISMIC
SEISMIC
SEISMIC
SEISMIC
SEISMIC
ROOF DIAPH. LENGTH 'L' -- FT.
61
92.8
92.8
96.8
11.5
11.5
ROOF DIAPH. SHEAR=V/L --- #/LF
21.4
33.5
30.1
18.8
178.7
50.9
USE ROOF DIAPH.
R1/F1
ROOF-1
ROOF-1
ROOF-1
ROOF-1
ROOF-1
ROOF-1
SHEAR WALL PANELS--+---+--
3.5+3+5.5
4+4.75
9.5
14
11.5+17.5
9.25
TOTAL 'I' =-------- FT
12
8.75
9.5
14
29
9.25
* SHEAR CAPACITY ADJUSTMENT FACTOR 'Co'
1
1
1
1
1
1
WALL SHEAR v = V/ (I * Co) (#/LF)
108.8
354.9
293.7
129.6
70.9
63.2
SHEAR PANEL USED(SEE SCHEDULE)
9
10
9
9
9
9
ANCHOR BOLT USE u
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
PENAL HIGHT 'H1' FT.
9.0
9.0
9.0
9.0
9.0
9.0
SMALLEST PENAL LENGTH = 'L' FT
3
4
9.5
14
11.5
9.25
M.O.T. #FT
2936.25
12774.86
25110.00
16335.00
7334.22
5265.00
PANEL DL (ROOF+WALL) = 'W' #/FT
112.5
112.5
328.5
112.5
112.5
112.5
M.O.R = WLZ/2 #FT
506.3
900.0
14823.6
11025.0
7439.1
4812.9
D.L. REACTION FROM HEADER ='R'
0.0
0.0
0.0
0.0
0.0
0.0
UPLIFT ON PANEL # {(MOT-0.60xMOR)-R
877.5
3058.7
1706.9
694.3
1249.6
257.0
STRAP WITH FLOOR BELOW
CS16
CS16
ICS16
ICS16
ICS16
ICS16
* 'Co' SHEAR CAPACITY ADJUSTMENT FACTOR : ACCOUNTS FOR STRENGTH REDUCING EFFECT OF OPENING ON SHEAR WALL CAPACITY
51
MAINLAND ENGG. CONSULTANTS CORPORATION
Project:
SINGLE FAMILY DWELLING
Sheet
Location:
15712 - 72 AVE. WEST,EDMONDS WA
Job No.:
UR801
Date:
25-Aug-20
By:
BS
Chk:
AB
UPPER SEISMIC FORCE (SF) = 5.4 #/SQ FT. (ASD)
LATERAL ANALYSIS (ALONG GRID #1 TO #7) WIND FORCE (WF) = 130 PLF (INTERIOR ZONE)
196 PLF (END ZONE)
END ZONE
INTERIOR ZONE
END ZONE
SHEAR LINE for level above
1
2
3
4
5
6/ 6.1
7
SHEAR FROM ROOF @ LINE 'Vr'
0
1305
3105
2790
1815
2055
585
SHEAR LINE AT THIS LEVEL
1
2
3
4
5
6/ 6.1
7
TRIB. WALL LENGTH FOR WIND FORCES ='B' ft
0.0
3.8
6.0
8.3
5.3
4.3
3.0
WIND SHEAR FORCE(THIS LEVEL) = B*WF
0
734
1175
1069
687
842
588
TRIB. SEISMIC AREA = 'A' SQ.FT=
195
290
443
590
441
283
171
SEISMIC SHEAR FORCE(THIS LEVEL) 'V' = A*SF
1045
1554
2374
3162
2364
1517
917
GOVERNING LOAD (W (wind) or E (Seismic)
SEISMIC
SEISMIC
SEISMIC
SEISMIC
SEISMIC
SEISMIC
SEISMIC
TOTAL SHEAR FORCE AT THIS LEVEL'V'-=
1045
2859
5479
5952
4179
3572
1502
FLOOR DIAPH. LENGTH 'L' -- FT.
27.5
61
92.8
92.8
96.8
71.5
22.5
FLOOR DIAPH. SHEAR=V/L --- #/LF
38.0
25.5
25.6
34.1
24.4
21.2
40.7
USE ROOF/ FLOOR DIAPH.
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
SHEAR WALL PANELS--+---+--
0
z
m D
Lw 0
N J
Lu Lu
m �
O =
3.75+3.5
6
3.25+3.25+5.7
5
4.5+3.25
11+28
22.5
TOTAL 'I' =-------- FT
7.25
6
12.25
7.75
39
22.5
* SHEAR CAPACITY ADJUSTMENT FACTOR 'Co'
1
1
1
1
1
1
WALL SHEAR v = V/ (I * Co) (#/LF)
394.4
913.2
485.9
539.2
91.6
66.7
SHEAR PANEL USED(SEE SCHEDULE)
10
13
11
11
9
9
ANCHOR BOLT USE
1
N.A.
N.A.
N.A.
1
1
PENAL HIGHT 'H1' FT.
9.0
9.0
9.0
9.0
9.0
9.0
SMALLEST PENAL LENGTH = 'L' FT
3.5
6
3.25
3.25
11
22.5
M.O.T. #FT
13604.9
59694.9
24731.6
16505.4
17881.2
33862.6
PANEL DL (ROOF+FLOOR+WALL) = 'W' #/FT
225.0
225.0
260.0
170.0
387.0
225.0
M.O.R = WLZ/2 #FT
1378.1
4050.0
1373.1
897.8
23413.5
56953.1
D.L. REACTION FROM HEADER ='R'
0.0
200.0
0.0
0.0
0.0
0.0
UPLIFT ON PANEL # {(MOT-0.60xMOR)-R
3650.9
9344.1
7356.2
4912.8
95.0
-13.7
STRAP WITH FLOOR BELOW
HD5B
2-CMST14
CMST12
ICMST14
I NOT REQ.
I NOT REQ.
52
MAINLAND ENGG. CONSULTANTS CORPORATION
Project:
SINGLE FAMILY DWELLING
Sheet
Location:
15712 - 72 AVE. WEST,EDMONDS WA
Job No.:
UR801
Date:
25-Aug-20
By:
BS
Chk:
AB
MAIN SEISMIC FORCE (SF) = 2.3 #/SQ FT. (ASD)
LATERAL ANALYSIS (ALONG GRID #1 TO #7) WIND FORCE (WF) = 130 PLF (INTERIOR ZONE)
196 PLF (END ZONE)
END ZONE
INTERIOR ZONE
END ZONE
SHEAR LINE for level above
1
2
3
4
5
6/ 6.1
7
TOTAL SHEAR FROM ABOVE @ LINE 'Vr'
1045
2859
5479
5952
4179
3572
1502
SHEAR LINE AT THIS LEVEL
1
2
3
4
5
6/ 6.1
7
TRIB. WALL LENGTH FOR WIND FORCES ='B' ft
0.0
7.5
6.0
8.3
6.3
6.8
2.8
WIND SHEAR FORCE(THIS LEVEL) = B*WF
0
1469
1175
1069
810
1322
548
TRIB. SEISMIC AREA = 'A' SQ.FT=
319
1088
480
797
535
393
78
SEISMIC SHEAR FORCE(THIS LEVEL) 'V' = A*SF
744
2537
1119
1859
1248
917
182
GOVERNING LOAD (W (wind) or E (Seismic)
SEISMIC
SEISMIC
WIND
SEISMIC
SEISMIC
WIND
WIND
TOTAL SHEAR FORCE AT THIS LEVEL'V'-=
1789
5397
6655
7811
5426
4894
2050
FLOOR DIAPH. LENGTH 'L' -- FT.
45
61
92.8
92.8
96.8
94.25
22.5
FLOOR DIAPH. SHEAR=V/L --- #/LF
16.5
41.6
12.7
20.0
12.9
14.0
24.4
USE ROOF/ FLOOR DIAPH.
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
SHEAR WALL PANELS--+---+--
z
o f
H O
U
N J
w
owc
CO N
O0 =
Q
z
O
U
}
CO8.0
0
w
w
O
4.75+4.25+3.7
5
20+5+13
7
J
Q
z
O
m
F-
cn
Lu
w
O
~
J
Q
z
Ov
m
�
cn
Lu
Lu
O
~
TOTAL 'I' =-------- FT
12.75
38
7
SHEAR CAPACITY ADJUSTMENT FACTOR 'Co'
1
1
1
WALL SHEAR v = V/ (I * Co) (#/LF)
521.9
205.6
775.2
SHEAR PANEL USED(SEE SCHEDULE)
11
9
13
ANCHOR BOLT USE
2
1
3
PENAL HIGHT H1' FT.
8.0
0
8.v
SMALLEST PENAL LENGTH = 'L' FT
3.75
5
7
M.O.T. #FT
49235.8
47209.2
73760.3
PANEL DL (ROOF+FLOOR+WALL) _ 'W' #/FT
382.5
470.0
430.0
M.O.R = WL2/2 #FT
2689.5
5875.0
10535.0
D.L. REACTION FROM HEADER ='R'
500.0
100.0
225.0
UPLIFT ON PANEL # {(MOT-0.60xMOR)-R
12199.2
4504.5
9409.2
HOLDOWN WITH FLOOR BELOW
HD12
HD513
jHD9B
53
MAINLAND ENGG. CONSULTANTS CORPORATION
Project:
SINGLE FAMILY DWELLING
Sheet
Location:
15712 - 72 AVE. WEST,EDMONDS WA
Job No.:
UR801
Date:
25-Aug-20
By:
BS
Chk:
AB
ROOF SEISMIC FORCE (SF) = 3.8 #/SQ FT. (ASD)
LATERAL ANALYSIS (ALONG GIRD #ATO #G) WIND FORCE (WF) = 82 PLF (INTERIOR ZONE)
120 PLF (END ZONE)
END ZONE
INTERIOR ZONE
END ZONE
SHEAR LINE
A/A.1
B
C
D
G
TRIB. WALL LENGTH FOR WIND FORCES ='B' ft
13.0
16.0
16.5
24.0
25.0
WIND SHEAR FORCE = B*WF
1559
1308
1349
1963
2997
TRIB. SEISMIC AREA = 'A' SQ.FT=
412
518
555
867
779
SEISMIC SHEAR FORCE 'V' = A*SF
1545
1943
2081
3251
2921
GOVERNING LOAD (W (wind) or E (Seismic)
WIND
SEISMIC
SEISMIC
SEISMIC
WIND
ROOF DIAPH. LENGTH 'L' -- FT.
34.25
34.25
36.5
35.5
33.7
ROOF DIAPH. SHEAR=V/L --- #/LF
45.1
56.7
57.0
91.6
86.7
USE ROOF DIAPH.
R1/F1
ROOF-1
ROOF-1
ROOF-1
ROOF-1
ROOF-1
SHEAR WALL PANELS--+---+--
8
7.5+5.5
12+7.5
8.75
18.25+10
TOTAL 'I' =-------- FT
8
13
19.5
8.75
28.25
* SHEAR CAPACITY ADJUSTMENT FACTOR ' Co'
1
1
1
1
1
WALL SHEAR v = V/ (I * Co) (#/LF)
194.8
149.4
106.7
371.6
106.1
SHEAR PANEL USED(SEE SCHEDULE)
9
9
9
10
9
ANCHOR BOLT USE
N.A.
N.A.
N.A.
N.A.
N.A.
PENAL HIGHT 'H1' FT.
9.0
9.0
9.0
9.0
9.0
SMALLEST PENAL LENGTH = 'L' FT
8
5.5
7.5
8.75
10
M.O.T. #FT
14027.67
7396.44
7204.33
29261.25
9549.13
PANEL DL (ROOF+WALL) = 'W' #/FT
274.5
310.5
229.5
409.5
337.5
M.O.R = WL2/2 #FT
8784.0
4696.3
6454.7
15676.2
16875.0
D.L. REACTION FROM HEADER ='R'
0.0
0.0
0.0
595.0
0.0
UPLIFT ON PANEL # {(MOT-0.60xMOR)-R
1094.7
832.5
444.2
1674.2
-57.6
STRAP WITH FLOOR BELOW
CS16
ICS16
ICS16
ICS16
I NOT REQ.
54
MAINLAND ENGG. CONSULTANTS CORPORATION
Project:
SINGLE FAMILY DWELLING
ISheet
Location:
15712 - 72 AVE. WEST,EDMONDS WA
lJob No.:
JUR801
Date:
25-Aug-20
I By:
IBS
Chk:
JAB
UPPER SEISMIC FORCE (SF) = 5.4 #/SQ FT. (ASD)
LATERAL ANALYSIS (ALONG GIRD #ATO #G) WIND FORCE (WF) = 130 PLF (INTERIOR ZONE)
196 PLF (END ZONE)
END ZONE
INTERIOR ZONE
END ZONE
SHEAR LINE for level above
A/A.1
B
C
D
E
G
SHEAR FROM ROOF @ LINE 'Vr'
1559
1943
2081
3251
0
2997
SHEAR LINE AT THIS LEVEL
A/A.1
B
C
D
E
G
TRIB. WALL LENGTH FOR WIND FORCES ='B' ft
11.3
17.8
17.5
8.5
26.5
13.0
WIND SHEAR FORCE(THIS LEVEL) = B*WF
2213
2306
2267
1101
3433
2546
TRIB. SEISMIC AREA = 'A' SQ.FT=
273
494
176
41
774
606
SEISMIC SHEAR FORCE(THIS LEVEL) 'V' = A*SF
1463
2648
943
220
4149
3248
GOVERNING LOAD (W (wind) or E (Seismic)
WIND
SEISMIC
WIND
WIND
SEISMIC
SEISMIC
TOTAL SHEAR FORCE AT THIS LEVEL'V'-=
3772
4590
4348
4352
4149
6246
FLOOR DIAPH. LENGTH 'L' -- FT.
30
30
17
4.5
52
52
FLOOR DIAPH. SHEAR=V/L --- #/LF
73.8
88.3
133.4
202.0
79.8
62.5
USE ROOF/ FLOOR DIAPH.
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
FLOOR-1
SHEAR WALL PANELS--+---+--
6.5
5.5+7
7.5+12
8.75
7.75
21+5
TOTAL 'I' =-------- FT
6.5
12.5
19.5
8.75
7.75
26
* SHEAR CAPACITY ADJUSTMENT FACTOR ' Co'
1
1
1
1
1
1
WALL SHEAR v = V/ (I * Co) (#/LF)
580.2
367.2
223.0
497.4
535.3
240.2
SHEAR PANEL USED(SEE SCHEDULE) A
12
10
9
11
11
9
ANCHOR BOLT USE
N.A.
1
N.A.
N.A.
N.A.
1
PENAL HIGHT 'H1' FT.
9.0
9.0
9.0
9.0
9.0
9.0
SMALLEST PENAL LENGTH = 'L' FT
6.5
5.5
7.5
8.75
7.75
5
M.O.T. #FT
42711.9
25278.3
22255.8
68432.3
52138.9
5621.8
PANEL DL (ROOF+FLOOR+WALL) = 'W' #/FT
508.5
706.5
319.5
522.0
90.0
510.0
M.O.R = WL2/2 #FT
10742.1
10685.8
8985.9
19982.8
2702.8
6375.0
D.L. REACTION FROM HEADER ='R'
0.0
0.0
0.0
595.0
0.0
0.0
UPLIFT ON PANEL # {(MOT-0.60xMOR)-R
5579.5
3430.3
2248.E
5855.E
6518.4
359.4
STRAP WITH FLOOR BELOW
ICMST14
HD5B
ICS16
ICMST14
ICMST12
HD5113
55
MAINLAND ENGG. CONSULTANTS CORPORATION
Project:
ISINGLE FAMILY DWELLING
Sheet
Location:
115712 - 72 AVE. WEST,EDMONDS WA
Job No.:
JUR801
Date:
25-Aug-20
By:
IBS
Chk:
JAB
MAIN SEISMIC FORCE (SF) = 2.3 #/SQ FT. (ASD)
LATERAL ANALYSIS (ALONG GIRD #ATO #G) WIND FORCE (WF) = 130 PLF (INTERIOR ZONE)
196 PLF (END ZONE)
END ZONE
INTERIOR ZONE
END ZONE
SHEAR LINE for level above
A/A.1
B
C
D
E
B/W E& F
G
TOTAL SHEAR FROM ABOVE @ LINE 'Vr'
3772
4590
4348
4352
4149
0
6246
SHEAR LINE AT THIS LEVEL
A/A.1
B
C
D
E
B/W E& F
G
TRIB. WALL LENGTH FOR WIND FORCES ='B' ft
11.3
20.8
14.5
7.0
0.0
35.5
9.8
WIND SHEAR FORCE(THIS LEVEL) = B*WF
2213
2694
1878
907
0
4599
1909
TRIB. SEISMIC AREA = 'A' SO.FT=
410
656
1446
1212
10
1695
418
SEISMIC SHEAR FORCE(THIS LEVEL) 'V' = A*SF
956
1530
1040
494
0
3953
975
GOVERNING LOAD (W (wind) or E (Seismic)
WIND
WIND
WIND
WIND
WIND
WIND
WIND
TOTAL SHEAR FORCE AT THIS LEVEL'V'-=
5985
2306
6227
5259
4149
4599
8155
FLOOR DIAPH. LENGTH 'L' -- FT.
35
30
17
46
50
20.5
50
FLOOR DIAPH. SHEAR=V/L --- #/LF 63.2 189.8 1110.5 119.7 10.0 1205.5 138.2
USE ROOF/ FLOOR DIAPH. FLOOR-1 FLOOR-1 FLOOR-1 FLOOR-1 I FLOOR-1 I FLOOR-1 FLOOR-1
SHEAR WALL PANELS--+---+- 12+7.25 114.75 1 115.5
TOTAL 'I' =-------- FT
Lu
O
-j
<
19.25
14.75
15.5
1
296.7
J
SHEAR CAPACITY ADJUSTMENT FACTOR ' Co'
1
1
J
WALL SHEAR v = V/ (I . Co) (#/LF)
323.5
356.6
Q
�
SHEAR PANEL USED(SEE SCHEDULE)
Q
=
Co
0
Ln
w
v
z
uv
Coco7.25
�
I---
N
cc
10
10
10
6
0
}
H
N
Lu
ANCHOR BOLT USE
1
1
z
1
8.0
14.75
35009.2
80.0
PENAL HIGHT 'H1' FT.
8.0
8.0
O
c�
SMALLEST PENAL LENGTH = 'L' FT
14.75
Co
M.O.T. #FT
40292.5
168470.4
0
PANEL DL (ROOF+FLOOR+WALL) = 'W' #/FT
697.5
1057.5
V)
M.O.R = WL2/2 #FT
18331.2
115036.2
w
8702.5
m Lu
<
-- "
m
O
m
D.L. REACTION FROM HEADER ='R'
0.0
600.0
U-im
0.0
UPLIFT ON PANEL # {(MOT-0.60xMOR)-R
4040.5
4250.0
p
2019.5
HOLDOWN WITH FLOOR BELOW
HD5B
HD5B
~
HD5B
56
MAINLAND ENGINEERING CONSULTANTS CORPORATION
Project:
SINGLE FAMILY DWELLING
ISheet
Location:
15712 - 72 AVE. WEST,EDMONDS WA
lJob No.:
UR801
Date:
26-Aug-20
By:
BS
Chk:
AB
MAX FRAMING / WALL LOAD AT CONC GRADE BEAM
FRAMING/WALL LOAD
ROOF LOAD
FLOOR
LOAD
WALL -LOAD
GRADE BEAM
(GRID LINES)
DL+LL
Max.
Span
CONC. WALL
STUD WALL
LOAD
HEIGHT
TOTAL
LBS/FT
SEE CAL
LL+DL
HEIGHT
DL+LL
Span
WALL -
1 / 7'
43
28
100
10
74
28
12
30
4636
CF-2
4039.75
WALL - A / G
43
20.75
100
10
74
20.75
12
51
CF-2
57
MAINLAND ENGINEERING CONSULTANTS CORPORATION
APPENDIX - A
DOUGLAS FIR- LARCH FRAMING LUMBER
2" - 4" THICK
2" - 4" THICK
BEAMS &
POSTS &
2" & WIDER
2" & WIDER
STRINGERS
TIMBERS
GRADE #2
GRADE #1
GRADE #1
GRADE #1
(PSI)
(PSI)
(PSI)
(PSI)
Fb (SGL)
875
1000
1350
1200
Fb (REP)
1006
1000
Ft
575
675
675
825
Fv
95
95
85
85
Fc (PERP)
625
1
1 625
625
625
Fc(PAR)
1300
1450
925
1000
E
1600000
1700000
1600000
1600000
SECTION PROPERTIES
SIZE
b
d
A
Cf
S
CFS
I
WEIGHT
(IN)
(IN)
(IN2)(IN3)
(IN3)
(IN4)(PSF)
2 x 4
1.50
3.50
5.25
1.500
3.06
4.59
5.36
1.28
2 x 6
1.50
5.50
8.25
1.300
7.56
9.83
20.80
2.01
2 x 8
1.50
7.25
10.88
1.200
13.14
15.77
47.63
2.64
2 x 10
1.50
9.25
13.88
1.100
21.39
23.53
98.93
3.37
2 x 12
1.50
11.25
16.88
1.000
31.64
31.64
177.98
4.10
2 x 14
1.50
13.25
19.88
0.900
43.89
39.50
290.78
4.83
4 x 4
1 3.50
3.50
12.25
1.500
7.15
10.72
12.51
2.98
4 x 6
3.50
5.50
19.25
1.300
17.65
22.94
48.53
4.68
4 x 8
3.50
7.25
25.38
1.200
30.66
36.79
111.15
6.17
4 x 10
3.50
9.25
32.38
1.100
49.91
54.90
230.84
7.87
4 x 12
3.50
11.25
39.38
1.000
73.83
73.83
415.28
9.57
4 x 14
3.50
13.50
47.25
0.900
106.31
95.68
717.61
11.48
6 x 6
5.50
5.50
30.25
1.000
27.73
27.73
76.26
7.35
6 x 8
5.50
7.50
41.25
1.000
51.56
51.56
193.36
10.03
6 x 10
5.50
9.50
52.25
1.000
82.73
82.73
392.96
12.70
6 x 12
5.50
11.50
63.25
1.000
121.23
121.23
697.07
15.37
6 x 14
5.50
13.50
74.25
0.987
167.06
164.89
1127.67
18.05
8 x 8
7.50
7.50
56.25
1.000
70.31
70.31
263.67
13.67
8 x 10
7.50
9.50
71.25
1.000
112.81
112.81
535.86
17.32
8 x 12
7.50
11.50
86.25
1.000
165.31
165.31
950.55
20.96
8 x 14
7.50
13.50
101.25
0.987
227.81
224.85
1537.73
24.61
MAINLAND ENGINEERING CONSULTANTS CORPORATION
APPENDIX -B
SHEAR WALL SCHEDULE PER 2015 IBC
FRAMING NOTES: -
A)
ALL EXTERIOR WALL TO BE SECURED WITH 1/2" DIA.x12" ANCHOR BOLTS AT 64" O.C.
UNLESS NOTED OTHERWISE.
B)
AN ALTERNATE TO ANCHOR BOLTS USE PHILLIPS RED HEAD SCREWS
C)
ALL INTERIOR WALLS TO BE ANCHORED WITH SHOT PINS (RAMSET # 3348 OR EQUIV.)
AT 36" O.C. AT BEARING WALLS AND 48" O.. AT NON BEARING
D)
WHERE PANELS ARE APPLIED ON BOTH FACES OF WALL AND NAIL SPACING IS LESS
6 INCHES ON CENTER ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON
DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3 INCHES NOMINAL OR THICKER
AND NAILS ON EACH SIDE SHALL BE STAGGERED.
E)
A MINIMUM OF 1/2" EDGE DISTANCE IS REQUIRED FOR NAILING AT THE 3x BOUNDARY
AND PANEL EDGE MEMBERS OF THE SHEAR WALL UNLESS OTHERWISE NOTED.
MARK
DESCRIPTION
SHEAR
PLATE TO BLKG.
0
#/FT.
NAILING REQ..
2
1/2" DRYWALL WITH 5d COOLER NAILS @ 7" O.C. EDGES
100
16d @ 12" O.C.
& FIELD (TABLE 4.3C SDPWS)
OR A35 @ 40" O.C.
3
5/8" DRYWALL WITH 6d COOLER NAILS @ 7" O.C. EDGES
115
16d @ 12" O.C.
& FIELD (TABLE 4.3C SDPWS)
OR A35 @ 40" O.C.
4
5/8" DRYWALL WITH 6d COOLER NAILS @ 4" O.C. EDGES
145
16d @ 12" O.C.
& FIELD (TABLE 4.3C SDPWS)
OR A35 @ 40" O.C.
5
1/2" DRYWALL BLOCKED WITH 5d COOLER NAILS @ 4" O.C.
150
16d @ 12" O.C.
EDGES & FIELD (TABLE 4.3C SDPWS)
OR A35 @ 40" O.C.
6
5/8" DRYWALL BLOCKED WITH 6d COOLER NAILS @ 4" O.C.
175
16d @ 8" O.C.
EDGES & FIELD (TABLE 4.3C SDPWS)
OR A35 @ 32" O.C.
7
7/8" STUCCO OVER PAPER BACKED LATH W/16 GAUGE GALV.
180
16d @ 8" O.C.
STAPLES AT 6" O.C. AT TOP & BOTTOM PLATES, EDGE
OR A35 @ 32" O.C.
OF SHEAR WALL & ON FIELD (TABLE 4.3C SDPWS)
8
NOT USED
-----
--------
9
3/8" STRUCTURAL I PLYWOOD WITH 8d NAILS @ 6" O.C. AT
280
16d @ 5" O.C.
EDGES & 12" O.C. FIELD (TABLE 4.3A 2008 SDPWS) W/2x FRAMING *
OR A35 @ 20" O.C.
10
3/8" STRUCTURAL I PLYWOOD WITH 8d NAILS @ 4" O.C. AT
430
16d @ 3-1/2" O.C.
EDGES & 12" O.C. FIELD (TABLE 4.3A 2008 SDPWS) W/2x FRAMING *
OR A35 @ 12" O.C.
11
3/8" STRUCTURAL I PLYWOOD WITH 8d NAILS @ 3" O.C. AT
550
16d @ 3" O.C.
EDGES & 12" O.C. FIELD (TABLE 4.3A 2008 SDPWS) W/2x FRAMING *
OR A35 @ 10" O.C.
12
15/32" STRUCTURAL I PLYWOOD WITH 10d NAILS @ 3" O.C. AT
665
A35 @ T' O.C.
EDGES & 12" O.C. FIELD (TABLE 4.3A 2008 SDPWS) W/2x FRAMING **
13
15/32" STRUCTURAL I PLYWOOD WITH 10d NAILS @ 2" O.C. AT
870
A35 @ T' O.C.
EDGES & 12" O.C. FIELD (TABLE 4.3A 2008 SDPWSC) W/2x FRAMING **
NOTE: * 1. STUDS ARE SPACED A MAXIMUM OF 16" O/C
OR
2. PANELS ARE APPLIED WITH LONG DIMENSION ACROSS STUDS.
*
FRAMING AT ADJOINING PANEL EDGES SHALL BE 3" NOMINAL OR WIDER, AND NAILS
SHALL BE STAGGERED WHERE BOTH OF THE FOLLOWING CONDITIONS ARE MET:
1. 10d NAILS HAVING PENETRATION IN TO FRAMING OF MORE THAN 1-1/2 IN.
2. NAILS ARE SPACED 3 IN. O/C
MAINLAND ENGINEERING CONSULTANTS CORPORATION
APPENDIX - C
ANCHOR BOLT SCHEDULE
MARK
DESCRIPTION
SHEAR
O
PER NDS2005
#/FT.
1
5/8" DIA. x 12" ANCHOR BOLTS @ 48" O/C IN 2 x PLATE'
429
2
5/8" DIA. x 12" ANCHOR BOLTS @ 32" O/C IN 2 x PLATE'
644
3
5/8" DIA. x 12" ANCHOR BOLTS @ 24" O/C IN 2 x PLATE
859
4
5/8" DIA x 12" ANCHOR BOLTS @ 16" O/C IN 2 x PLATE
1289
ROOF / FLOOR DIAPHRAGM SCHEDULE
MARK
DESCRIPTION
SHEAR
0
PER TABLE4.2A/4.2C 2008 SDPWS (AF&PA)
#/FT.
ROOF-1
15/32" STRUCTURAL I UNBLOCKED W/10d" NAILS @ 6", 6", &
215
12" O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
ALL CASES
ROOF-2
15/32" STRUCTURAL I UNBLOCKED W/10d" NAILS @ 6", 6", &
285
10" O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
CASE 1
ROOF-3
15/32" STRUCTURAL I BLOCKED W/10d" NAILS @ 4", 6", &
425
10" O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
ROOF-4
15/32" STRUCTURAL I BLOCKED W/10d" NAILS @ 2.5", 4", &
575
10" O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
ROOF-5
15/32" STRUCTURAL I BLOCKED W/10d" NAILS @ 2", 3", & 10" O/C AT
730
BOUNDARY, EDGE AND FIELD RESPECTIVELY
FLOOR-1
19/32" CDX PLYWOOD UNBLOCKED W/10d" NAILS @ 6", 6", &
215
12" O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
ALL CASES
FLOOR-2
19/32" CDX PLYWOOD UNBLOCKED W/10d" NAILS @ 6", 6", &
285
12" O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
CASE 1
FLOOR-3
19/32" CDX PLYWOOD BLOCKED W/10d" NAILS @ 4", 6", &
425
10" O/C AT BOUNDARY, EDGE AND FIELD RESPECTIVELY
Note : * Sill plate is anchored by two times the required number of bolts per table 1911.2
Framing at adjoining panel edges shall be 3 inches nominal or wider and nails
shall be staggered where both of the following conditions are met:
1. 10d nails having penetration into framing of more than 1-1/2 inches and
2. Nails are spaced 3 inches o/c or less.
MAINLAND ENGINEERING CONSULTANTS CORPORATION
APPENDIX - D
ALLOWABLE LOADS
SOIL BEARING CAPACITY = 3000 PSF PER SOIL REPORT BY
GEOTECH CONSULTANTS, INC.
2401 10TH AVE. E SEATTLE, WASHINGTON 98102
PROJECT NO.- JN 18021
DATED- JANUARY 25, 2018
PHONE NO.- (425) 747-5618
A. CONTINUOUS FOOTINGS
FOR 24" DEEP CONTINUOUS FOOTINGS
NET SOIL BEARING = 2,700 PLF
CF-1
18" WIDE x 24" DEEP W/ 1 #4 AT TOP & 244 AT BOTTOM
W/ #4 TRANSVERSE REBARS @ 24" O.0
CAPACITY = 2700 X 1.5 = 4,050
PLF
CF-2
24" WIDE x 24" DEEP W/ 2 #5 AT TOP & 245 AT BOTTOM
W/ #4 TRANSVERSE REBARS @ 24" O.0
CAPACITY = 2,700 x 2.0 = 5,400
PLF
CF-3
27" WIDE x 24" DEEP W/ 2 #5 AT TOP & 345 AT BOTTOM
W/ #4 TRANSVERSE REBARS @16" O.0
CAPACITY = 2,700 2.25 = 6,075
PLF
B. ISOLATED PAD FOOTINGS
F-1
2'-6" x2'-6" SQ. X 18" DEEP W/ -3 #5 REBAR AT BOTTOM EA. WAY
CAPACITY = 2,700 x 2.5 2 = 16,875
#
F-2
T-0" xT-0" SQ. X 18" DEEP W/ -4 #5 REBAR AT BOTTOM EA. WAY
CAPACITY = 2,700 x 3 2 = 24,300
#
F-3
T-6" x3'-6" SQ. X 18" DEEP W/ -5 #5 REBAR AT BOTTOM EA. WAY
CAPACITY = 2,700 x 3.5 2 = 33,075
#
F-4
4'-0" x4'-0" SQ. X 18" DEEP W/ -5 #5 REBAR AT BOTTOM EA. WAY
CAPACITY = 2,700 x 4.0 2 = 43,200
#
F-5
5-0" x5'-0" SQ. X 18" DEEP W/ -7 #5 REBAR AT BOTTOM EA. WAY
CAPACITY = 2,700 x 5.0 2 = 67,500
#
F-6
6'-0" x6'-0" SQ. X 20" DEEP W/ -10 #5 REBAR AT BOTTOM EA. WAY
CAPACITY = 2,700 x 6.0 2 = 97,200
#
F-7
8'-0" x8'-0" SQ. X 24" DEEP W/ -14 #5 REBAR AT BOTTOM EA. WAY
CAPACITY = 2,700 x 6.5 2 = 172,800
#
61
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Criteria
Soil Data
Retained Height =
4.00 ft
Allow Soil Bearing = 3,000.0 psf
Wall height above soil =
0.50 ft
Equivalent Fluid Pressure Method
Active Heel Pressure - 35.0 psf/ft
Slope Behind Wall =
0.00
Height of Soil over Toe =
8.00 in
=
Water height over heel =
0.0 ft
Passive Pressure = 0.0 psf/ft
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 Ibs
Axial Live Load = 0.0 Ibs
Axial Load Eccentricity = 0.0 in
Earth Pressure Seismic Load
Method : Uniform
Multiplier Used = 8.000
(Multiplier used on soil density)
Design Summary
Wall Stability Ratios
Overturning = 3.93 OK
Sliding = 1.71 OK
Total Bearing Load = 1,841 Ibs
...resultant ecc. = 2.40 in
Soil Pressure @ Toe =
706 psf OK
Soil Pressure @ Heel =
346 psf OK
Allowable =
3,000 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe =
989 psf
ACI Factored @ Heel =
484 psf
Footing Shear @ Toe =
3.2 psi OK
Footing Shear @ Hee =
3.0 psi OK
Allowable =
90.0 psi
Sliding Calcs
Lateral Sliding Force
539.6 Ibs
less 0 % Passive Force = -
0.0 Ibs
less 100% Friction Force = -
920.4 Ibs
Added Force Req'd =
0.0 Ibs OK
....for 1.5 Stability =
0.0 Ibs OK
Soil Density, Heel = 130.00 pcf
Soil Density, Toe = 0.00 pcf
FootingllSoil Friction = 0.500
Soil height to ignore
for passive pressure = 0.00 in
Lateral Load Applied to Stem
Lateral Load =
0.0 #/ft
...Height to Top =
0.00 ft
...Height to Bottom =
0.00 ft
Load Type =
Dead Load (D)
(Service Level)
Wind on Exposed Stem =
0.0 psf
(Service Level)
Uniform Seismic Force = 38.667
Total Seismic Force = 186.889
Stem Construction
Design Height Above Ftc
ft =
Wall Material Above "Ht"
_
Design Method
=
Thickness
=
Rebar Size
=
Rebar Spacing
=
Rebar Placed at
=
Design Data
fb/FB + fa/Fa
=
Total Force @ Section
Service Level
Ibs =
Strength Level
Ibs =
Moment.... Actual
Service Level
ft-# =
Strength Level
ft-# =
Moment..... Allowable
=
Shear..... Actual
Service Level
psi =
Strength Level
psi =
Shear..... Allowable
psi =
Anet (Masonry)
in2 =
Rebar Depth 'd'
in =
Masonry Data
f'm
psi =
Fs
psi =
Solid Grouting
=
Vertical component of active lateral soil pressure IS Modular Ratio 'n' _
considered in the calculation of soil bearing pressures. Wall Wei ht sf =
Load Factors -
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
IBC 2018,AC1
1.200
1.600
1.600
1.000
1.000
9 p
Short Term Factor =
Equiv. Solid Thick. _
Masonry Block Type =
Bottom
Adjacent Footing Load
Adjacent Footing Load =
0.0 Ibs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.300
Stem OK
0.00
Concrete
LRFD
8.00
# 5
16.00
Edge
0.145
602.7
906.7
6,274.3
8.1
90.0
6.19
11111111:
Masonry Design Method = ASD
Concrete Data
f'c psi =
Fy psi =
3,600.0
60,000.0
62
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Concrete Stem Rebar Area Details
Bottom Stem
Vertical Reinforcing
Horizontal Reinforcing
As (based on applied moment) :
0.0343 in2/ft
(4/3) * As :
0.0458 in2/ft
Min Stem T&S Reinf Area 0.864 in2
200bd/fy : 200(12)(6.1875)/60000 :
0.2475 in2/ft
Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft
0.0018bh : 0.0018(12)(8) :
0.1728 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
Required Area :
0.1728 in2/ft
#4@ 12.50 in #4@ 25.00 in
Provided Area :
0.2325 in2/ft
#5@ 19.38 in #5@ 38.75 in
Maximum Area :
1.207 in2/ft
#6@ 27.50 in #6@ 55.00 in
Footing Dimensions & Strengths
Toe Width
= 1.00 ft
Heel Width
= 2.50
Total Footing Width
= 3.50
Footing Thickness
= 10.00 in
Key Width
= 0.00 in
Key Depth
= 0.00 in
Key Distance from Toe
= 0.00 ft
fc = 3,600 psi Fy = 60,000 psi
Footing Concrete Density
= 150.00 pcf
Min. As %
= 0.0020
Cover @ Top 1.50
@ Btm: 3.00 in
Footing Design Results
Tee
Heel
Factored Pressure = 989
484 psf
Mu': Upward = 470
962 ft-#
Mu': Downward = 127
1,301 ft-#
Mu: Design = 343
339 ft-#
Actual 1-Way Shear = 3.18
3.01 psi
Allow 1-Way Shear = 48.00
48.00 psi
Toe Reinforcing = # 5 @ 12.00 in
Heel Reinforcing = # 5 @ 16.00 in
Key Reinforcing = None Spec'd
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi*5*lambda*sgrt(f'c)*Sm
Heel: Not req'd: Mu < phi*5*lambda*sgrt(fc)*Sm
Key: No key defined
Min footing T&S reinf Area 0.76 in2
Min footing T&S reinf Area per foot 0.22 in2 tft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 11.11 in #4@ 22.22 in
#5@ 17.22 in #5@ 34.44 in
#6@ 24.44 in #6@ 48.89 in
Summary of Overturning & Resisting Forces & Moments
.....OVERTURNING.....
.....RESISTING.....
Force Distance
Moment
Force Distance
Moment
Item Ibs ft
ft-#
Ibs ft
ft-#
Heel Active Pressure = 408.8 1.61
658.7
Soil Over Heel = 953.3 2.58
2,462.8
Surcharge over Heel =
Sloped Soil Over Hee =
Surcharge Over Toe =
Surcharge Over Heel =
Adjacent Footing Load =
Adjacent Footing Load =
Added Lateral Load =
Axial Dead Load on Sterr =
Load @ Stem Above Soil =
* Axial Live Load on Stem =
Seismic Earth Load = 130.8 2.42
316.2
Soil Over Toe = 0.50
=
Surcharge Over Toe =
Total 539.6 O.T.M.
974.8
Stem Weight(s) = 450.0 1.33
600.0
Earth @ Stem Transitions =
_ =
Footing Weigh = 437.5 1.75
765.6
Resisting/Overturning Ratio = 3.93
Key Weight =
Vertical Loads used for Soil Pressure = 1,840.8
Ibs
Vert. Component = 3.50
Total = 1,840.8 Ibs R.M.=
3,828.4
If seismic is included, the OTM and sliding ratios
* Axial live load NOT included in total displayed, or used for
overturning
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201
resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS considered in the
calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS considered in the
calculation of Overturning Resistance.
63
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 250.0 pci
Horizontal Defl @ Top of Wall (approximate only) 0.025 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
•E
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Criteria
Soil Data
Retained Height =
6.00 ft
Allow Soil Bearing - 3,000.0 psf
Wall height above soil =
0.50 ft
Equivalent Fluid Pressure Method
Active Heel Pressure - 35.0 psf/ft
Slope Behind Wall =
0.00
Height of Soil over Toe =
8.00 in
=
Water height over heel =
0.0 ft
Passive Pressure = 0.0 psf/ft
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 Ibs
Axial Live Load = 0.0 Ibs
Axial Load Eccentricity = 0.0 in
Earth Pressure Seismic Load
Method : Uniform
Multiplier Used = 8.000
(Multiplier used on soil density)
Design Summary
Wall Stability Ratios
Overturning = 3.63 OK
Sliding = 1.69 OK
Total Bearing Load = 3,649 Ibs
...resultant ecc. = 4.70 in
Soil Pressure @ Toe =
1,148 psf OK
Soil Pressure @ Heel =
389 psf OK
Allowable =
3,000 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe =
1,607 psf
ACI Factored @ Heel =
544 psf
Footing Shear @ Toe =
6.0 psi OK
Footing Shear @ Hee =
6.3 psi OK
Allowable =
90.0 psi
Sliding Calcs
Lateral Sliding Force
1,078.6 Ibs
less 0 % Passive Force = -
0.0 Ibs
less 100% Friction Force = -
1,824.4lbs
Added Force Req'd =
0.0 Ibs OK
....for 1.5 Stability =
0.0 Ibs OK
Soil Density, Heel = 130.00 pcf
Soil Density, Toe = 0.00 pcf
FootingllSoil Friction = 0.500
Soil height to ignore
for passive pressure = 0.00 in
Lateral Load Applied to Stem
Lateral Load =
0.0 #/ft
...Height to Top =
0.00 ft
...Height to Bottom =
0.00 ft
Load Type =
Dead Load (D)
(Service Level)
Wind on Exposed Stem =
0.0 psf
(Service Level)
Uniform Seismic Force = 54.667
Total Seismic Force = 373.556
Stem Construction
Design Height Above Ftc
ft =
Wall Material Above "Ht"
_
Design Method
=
Thickness
=
Rebar Size
=
Rebar Spacing
=
Rebar Placed at
=
Design Data
fb/FB + fa/Fa
=
Total Force @ Section
Service Level
Ibs =
Strength Level
Ibs =
Moment.... Actual
Service Level
ft-# =
Strength Level
ft-# =
Moment..... Allowable
=
Shear..... Actual
Service Level
psi =
Strength Level
psi =
Shear..... Allowable
psi =
Anet (Masonry)
in2 =
Rebar Depth 'd'
in =
Masonry Data
f'm
psi =
Fs
psi =
Solid Grouting
=
Vertical component of active lateral soil pressure IS Modular Ratio 'n' _
considered in the calculation of soil bearing pressures. Wall Wei ht sf =
Load Factors -
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
IBC 2018,AC1
1.200
1.600
1.600
1.000
1.000
9 p
Short Term Factor =
Equiv. Solid Thick. _
Masonry Block Type =
Bottom
Adjacent Footing Load
Adjacent Footing Load =
0.0 Ibs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.300
Stem OK
0.00
Concrete
LRFD
8.00
# 5
12.00
Edge
0.362
1,336.0
3,000.0
8,277.2
18.0
90.0
6.19
11111111:
Masonry Design Method = ASD
Concrete Data
f'c psi =
Fy psi =
3,600.0
60,000.0
65
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Concrete Stem Rebar Area Details
Bottom Stem
Vertical Reinforcing
Horizontal Reinforcing
As (based on applied moment) :
0.1136 in2/ft
(4/3) * As :
0.1515 in2/ft
Min Stem T&S Reinf Area 1.248 in2
200bd/fy : 200(12)(6.1875)/60000 :
0.2475 in2/ft
Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft
0.0018bh : 0.0018(12)(8) :
0.1728 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
Required Area :
0.1728 in2/ft
#4@ 12.50 in #4@ 25.00 in
Provided Area :
0.31 in2/ft
#5@ 19.38 in #5@ 38.75 in
Maximum Area :
1.207 in2/ft
#6@ 27.50 in #6@ 55.00 in
Footing Dimensions & Strengths
Toe Width
= 1.00 ft
Heel Width
= 3.75
Total Footing Width
= 4.75
Footing Thickness
= 10.00 in
Key Width
= 0.00 in
Key Depth
= 0.00 in
Key Distance from Toe
= 0.00 ft
fc = 3,600 psi Fy = 60,000 psi
Footing Concrete Density
= 150.00 pcf
Min. As %
= 0.0020
Cover @ Top 1.50
@ Btm: 3.00 in
Footing Design Results
Tee
Heel
Factored Pressure = 1,607
544 psf
Mu': Upward = 766
3,679 ft-#
Mu': Downward = 127
5,162 ft-#
Mu: Design = 639
1,483 ft-#
Actual 1-Way Shear = 6.05
6.33 psi
Allow 1-Way Shear = 48.00
48.00 psi
Toe Reinforcing = # 5 @ 10.00 in
Heel Reinforcing = # 5 @ 16.00 in
Key Reinforcing = None Spec'd
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi*5*lambda*sgrt(f'c)*Sm
Heel: Not req'd: Mu < phi*5*lambda*sgrt(fc)*Sm
Key: No key defined
Min footing T&S reinf Area
1.03 in2
Min footing T&S reinf Area per foot
0.22 in2 tft
If one layer of horizontal bars:
If two layers of horizontal bars:
#4@ 11.11 in
#4@ 22.22 in
#5@ 17.22 in
#5@ 34.44 in
#6@ 24.44 in
#6@ 48.89 in
Summary of Overturning & Resisting Forces & Moments
.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item Ibs ft ft-# Ibs ft ft-#
Heel Active Pressure = 817.2
2.28 1,861.3
Surcharge over Heel =
Surcharge Over Toe =
Adjacent Footing Load =
Added Lateral Load =
Load @ Stem Above Soil =
Seismic Earth Load = 261.5
3.42 893.4
Total 1,078.6
O.T.M. 2,754.7
Resisting/Overturning Ratio
= 3.63
Vertical Loads used for Soil Pressure =
3,648.8 Ibs
If seismic is included, the OTM and sliding ratios
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201
Vertical component of active lateral soil pressure IS considered in the
calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS considered in the
calculation of Overturning Resistance.
Soil Over Heel =
2,405.0
3.21
7,716.0
Sloped Soil Over Hee =
Surcharge Over Heel =
Adjacent Footing Load =
Axial Dead Load on Sterr =
* Axial Live Load on Stem =
Soil Over Toe =
0.50
Surcharge Over Toe =
Stem Weight(s) =
650.0
1.33
866.7
Earth @ Stem Transitions =
Footing Weigh =
593.8
2.38
1,410.2
Key Weight =
Vert. Component =
4.75
Total =
3,648.8
Ibs R.M.=
9,992.9
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
e
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 250.0 pci
Horizontal Defl @ Top of Wall (approximate only) 0.044 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
67
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Criteria
Soil Data
Retained Height =
8.00 ft
Allow Soil Bearing = 3,000.0 psf
Wall height above soil =
0.50 ft
Equivalent Fluid Pressure Method
Active Heel Pressure - 35.0 psf/ft
Slope Behind Wall =
0.00
Height of Soil over Toe =
8.00 in
=
Water height over heel =
0.0 ft
Passive Pressure = 0.0 psf/ft
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 Ibs
Axial Live Load = 0.0 Ibs
Axial Load Eccentricity = 0.0 in
Earth Pressure Seismic Load
Method : Uniform
Multiplier Used = 8.000
(Multiplier used on soil density)
Design Summary
Wall Stability Ratios
Overturning = 3.99 OK
Sliding = 1.71 OK
Total Bearing Load = 6,169 Ibs
...resultant ecc. = 4.42 in
Soil Pressure @ Toe =
1,272 psf OK
Soil Pressure @ Heel =
626 psf OK
Allowable =
3,000 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe =
1,781 psf
ACI Factored @ Heel =
877 psf
Footing Shear @ Toe =
14.2 psi OK
Footing Shear @ Hee =
9.9 psi OK
Allowable =
90.0 psi
Sliding Calcs
Lateral Sliding Force
1,802.4 Ibs
less 0 % Passive Force = -
0.0 Ibs
less 100% Friction Force = -
3,084.6 Ibs
Added Force Req'd =
0.0 Ibs OK
....for 1.5 Stability =
0.0 Ibs OK
Soil Density, Heel = 130.00 pcf
Soil Density, Toe = 0.00 pcf
FootingllSoil Friction = 0.500
Soil height to ignore
for passive pressure = 0.00 in
Lateral Load Applied to Stem
Lateral Load =
0.0 #/ft
...Height to Top =
0.00 ft
...Height to Bottom =
0.00 ft
Load Type =
Dead Load (D)
(Service Level)
Wind on Exposed Stem =
0.0 psf
(Service Level)
Uniform Seismic Force = 70.667
Total Seismic Force = 624.222
Stem Construction
I -
Design Height Above Ftc
ft =
Wall Material Above "Ht"
_
Design Method
=
Thickness
=
Rebar Size
=
Rebar Spacing
=
Rebar Placed at
=
Design Data
fb/FB + fa/Fa
=
Total Force @ Section
Service Level
Ibs =
Strength Level
Ibs =
Moment.... Actual
Service Level
ft-# =
Strength Level
ft-# =
Moment..... Allowable
=
Shear..... Actual
Service Level
psi =
Strength Level
psi =
Shear..... Allowable
psi =
Anet (Masonry)
in2 =
Rebar Depth 'd'
in =
Masonry Data
f'm
psi =
Fs
psi =
Solid Grouting
=
Vertical component of active lateral soil pressure IS Modular Ratio 'n' _
considered in the calculation of soil bearing pressures. Wall Wei ht sf =
Load Factors -
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
IBC 2018,AC1
1.200
1.600
1.600
1.000
1.000
9 p
Short Term Factor =
Equiv. Solid Thick. _
Masonry Block Type =
Bottom
Adjacent Footing Load
Adjacent Footing Load =
0.0 Ibs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.300
Stem OK
0.00
Concrete
LRFD
8.00
# 5
10.00
Edge
0.715
2,357.3
7,040.0
9,847.6
31.7
90.0
6.19
11111111:
Masonry Design Method = ASD
Concrete Data
f'c psi =
Fy psi =
3,600.0
60,000.0
e
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Concrete Stem Rebar Area Details
Bottom Stem
Vertical Reinforcing
Horizontal Reinforcing
As (based on applied moment) :
0.2666 in2/ft
(4/3) * As :
0.3554 in2/ft
Min Stem T&S Reinf Area 1.632 in2
200bd/fy : 200(12)(6.1875)/60000 :
0.2475 in2/ft
Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft
0.0018bh : 0.0018(12)(8) :
0.1728 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
Required Area :
0.2666 in2/ft
#4@ 12.50 in #4@ 25.00 in
Provided Area :
0.372 in2/ft
#5@ 19.38 in #5@ 38.75 in
Maximum Area :
1.207 in2/ft
#6@ 27.50 in #6@ 55.00 in
Footing Dimensions & Strengths
Toe Width
= 1.50 ft
Heel Width
= 5.00
Total Footing Width
= 6.50
Footing Thickness
= 10.00 in
Key Width
= 0.00 in
Key Depth
= 0.00 in
Key Distance from Toe
= 0.00 ft
fc = 3,600 psi Fy = 60,000 psi
Footing Concrete Density
= 150.00 pcf
Min. As %
= 0.0020
Cover @ Top 1.50
@ Btm: 3.00 in
Footing Design Results
Tee
Heel
Factored Pressure
= 1,781
877 psf
Mu': Upward
= 1,925
10,119 ft-#
Mu': Downward
= 286
13,126 ft-#
Mu: Design
= 1,639
3,007ft-#
Actual 1-Way Shear
= 14.23
9.92 psi
Allow 1-Way Shear
= 48.00
90.00 psi
Toe Reinforcing
= # 5 @ 6.00 in
Heel Reinforcing
= # 5 @ 14.00 in
Key Reinforcing
= None Spec'd
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi*5*lambda*sgrt(f'c)*Sm
Heel: #4@ 10.00 in, #5@ 15.50 in, #6@ 22.00 in, #7@ 30.00 in, #8@ 39.50 in, #9@ 5
Key: No key defined
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 11.11 in
#5@ 17.22 in
#6@ 24.44 in
1.40 in2
0.22 in2 tft
If two layers of horizontal bars:
#4@ 22.22 in
#5@ 34.44 in
#6@ 48.89 in
Summary of Overturning & Resisting Forces & Moments
.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item Ibs ft ft-# Ibs ft ft-#
Heel Active Pressure = 1,365.5
2.94 4,020.6
Surcharge over Heel =
Surcharge Over Toe =
Adjacent Footing Load =
Added Lateral Load =
Load @ Stem Above Soil =
Seismic Earth Load = 437.0
4.42 1,929.9
Total 1,802.4
O.T.M. 5,950.5
Resisting/Overturning Ratio
= 3.99
Vertical Loads used for Soil Pressure =
6,169.2 Ibs
If seismic is included, the OTM and sliding ratios
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201
Vertical component of active lateral soil pressure IS considered in the
calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS considered in the
calculation of Overturning Resistance.
Soil Over Heel =
4,506.7
4.33
19,528.9
Sloped Soil Over Hee =
Surcharge Over Heel =
Adjacent Footing Load =
Axial Dead Load on Sterr =
* Axial Live Load on Stem =
Soil Over Toe =
0.75
Surcharge Over Toe =
Stem Weight(s) =
850.0
1.83
1,558.3
Earth @ Stem Transitions =
Footing Weigh =
812.5
3.25
2,640.6
Key Weight =
Vert. Component =
6.50
Total =
6,169.2
Ibs R.M.=
23,727.8
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
M
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 250.0 pci
Horizontal Defl @ Top of Wall (approximate only) 0.046 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
70
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Criteria
Soil Data
Retained Height =
10.00 ft
Allow Soil Bearing = 2,700.0 psf
Wall height above soil =
0.50 ft
Equivalent Fluid Pressure Method
Active Heel Pressure - 35.0 psf/ft
Slope Behind Wall =
0.00
Height of Soil over Toe =
8.00 in
=
Water height over heel =
0.0 ft
Passive Pressure = 0.0 psf/ft
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 Ibs
Axial Live Load = 0.0 Ibs
Axial Load Eccentricity = 0.0 in
Earth Pressure Seismic Load
Method : Uniform
Multiplier Used = 8.000
(Multiplier used on soil density)
Design Summary
Wall Stability Ratios
Overturning = 3.50 OK
Sliding = 1.64 OK
Total Bearing Load = 9,015 Ibs
...resultant ecc. = 7.63 in
Soil Pressure @ Toe =
1,813 psf OK
Soil Pressure @ Heel =
590 psf OK
Allowable =
2,700 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe =
2,539 psf
ACI Factored @ Heel =
827 psf
Footing Shear @ Toe =
17.3 psi OK
Footing Shear @ Hee =
14.3 psi OK
Allowable =
90.0 psi
Sliding Calcs
Lateral Sliding Force
2,752.9 Ibs
less 0 % Passive Force = -
0.0 Ibs
less 100% Friction Force = -
4,507.3 Ibs
Added Force Req'd =
0.0 Ibs OK
....for 1.5 Stability =
0.0 Ibs OK
Soil Density, Heel = 130.00 pcf
Soil Density, Toe = 0.00 pcf
FootingllSoil Friction = 0.500
Soil height to ignore
for passive pressure = 0.00 in
Lateral Load Applied to Stem
Lateral Load =
0.0 #/ft
...Height to Top =
0.00 ft
...Height to Bottom =
0.00 ft
Load Type =
Dead Load (D)
(Service Level)
Wind on Exposed Stem =
0.0 psf
(Service Level)
Uniform Seismic Force = 87.333
Total Seismic Force = 953.389
Stem Construction
Design Height Above Ftc
ft =
Wall Material Above "Ht"
_
Design Method
=
Thickness
=
Rebar Size
=
Rebar Spacing
=
Rebar Placed at
=
Design Data
fb/FB + fa/Fa
=
Total Force @ Section
Service Level
Ibs =
Strength Level
Ibs =
Moment.... Actual
Service Level
ft-# =
Strength Level
ft-# =
Moment..... Allowable
=
Shear..... Actual
Service Level
psi =
Strength Level
psi =
Shear..... Allowable
psi =
Anet (Masonry)
in2 =
Rebar Depth 'd'
in =
Masonry Data
f'm
psi =
Fs
psi =
Solid Grouting
=
Vertical component of active lateral soil pressure IS Modular Ratio 'n' _
considered in the calculation of soil bearing pressures. Wall Wei ht sf =
Load Factors -
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
IBC 2018,AC1
1.200
1.600
1.600
1.000
1.000
9 p
Short Term Factor =
Equiv. Solid Thick. _
Masonry Block Type =
Bottom
Adjacent Footing Load
Adjacent Footing Load =
0.0 Ibs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.300
Stem OK
0.00
Concrete
LRFD
8.00
# 5
6.00
Edge
0.865
3,673.3
13,700.0
15, 845.7
49.5
90.0
6.19
11111111:
Masonry Design Method = ASD
Concrete Data
f'c psi =
Fy psi =
3,600.0
60,000.0
71
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Concrete Stem Rebar Area Details
Bottom Stem
Vertical Reinforcing
Horizontal Reinforcing
As (based on applied moment) :
0.5188 in2/ft
(4/3) * As :
0.6917 in2/ft
Min Stem T&S Reinf Area 2.016 in2
200bd/fy : 200(12)(6.1875)/60000 :
0.2475 in2/ft
Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft
0.0018bh : 0.0018(12)(8) :
0.1728 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
Required Area :
0.5188 in2/ft
#4@ 12.50 in #4@ 25.00 in
Provided Area :
0.62 in2/ft
#5@ 19.38 in #5@ 38.75 in
Maximum Area :
1.207 in2/ft
#6@ 27.50 in #6@ 55.00 in
Footing Dimensions & Strengths
Toe Width
= 1.50 ft
Heel Width
= 6.00
Total Footing Width
= 7.50
Footing Thickness
= 11.00 in
Key Width
= 0.00 in
Key Depth
= 0.00 in
Key Distance from Toe
= 0.00 ft
fc = 3,600 psi Fy = 60,000 psi
Footing Concrete Density
= 150.00 pcf
Min. As %
= 0.0020
Cover @ Top 1.50
@ Btm: 3.00 in
Footing Design Results
Tee
Heel
Factored Pressure
= 2,539
827 psf
Mu': Upward
= 2,728
17,528 ft-#
Mu': Downward
= 303
24,533 ft-#
Mu: Design
= 2,425
7,005 ft-#
Actual 1-Way Shear
= 17.30
14.30 psi
Allow 1-Way Shear
= 48.00
90.00 psi
Toe Reinforcing
= None Spec'd
Heel Reinforcing
= # 5 @ 12.00 in
Key Reinforcing
= None Spec'd
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi*5*lambda*sgrt(f'c)*Sm
Heel: #4@ 9.09 in, #5@ 14.09 in, #6@ 20.00 in, #7@ 27.27 in, #8@ 35.91 in, #9@ 45
Key: No key defined
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 10.10 in
#5@ 15.66 in
#6@ 22.22 in
1.78 in2
0.24 in2 tft
If two layers of horizontal bars:
#4@ 20.20 in
#5@ 31.31 in
#6@ 44.44 in
Summary of Overturning & Resisting Forces & Moments
.....OVERTURNING..... .....RESISTING.....
Force Distance Moment Force Distance Moment
Item Ibs ft ft-# Ibs ft ft-#
Heel Active Pressure = 2,085.5
3.64 7,589.0
Surcharge over Heel =
Surcharge Over Toe =
Adjacent Footing Load =
Added Lateral Load =
Load @ Stem Above Soil =
Seismic Earth Load = 667.4
5.46 3,642.7
Total 2,752.9
O.T.M. 11,231.8
Resisting/Overturning Ratio
= 3.50
Vertical Loads used for Soil Pressure =
9,014.6 Ibs
If seismic is included, the OTM and sliding ratios
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201
Vertical component of active lateral soil pressure IS considered in the
calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS considered in the
calculation of Overturning Resistance.
Soil Over Heel =
6,933.3
4.83
33,511.1
Sloped Soil Over Hee =
Surcharge Over Heel =
Adjacent Footing Load =
Axial Dead Load on Sterr =
* Axial Live Load on Stem =
Soil Over Toe =
0.75
Surcharge Over Toe =
Stem Weight(s) =
1,050.0
1.83
1,925.0
Earth @ Stem Transitions =
Footing Weigh =
1,031.3
3.75
3,867.2
Key Weight =
Vert. Component =
7.50
Total =
9,014.6
Ibs R.M.=
39,303.3
* Axial live load NOT included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
72
Retain Pro (c) 1987-2018, Build 11.18.06.30
License : KW-06060370 Cantilevered Retaining Wall Code: IBC 2018,AC1 318-14,TMS 402-16
License To: MAINLAND ENGINEERING CONSULTANTS CORPORATION
Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 250.0 pci
Horizontal Defl @ Top of Wall (approximate only) 0.071 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
73
Tuesday, April 02, 2019, 11:00 PM
PAGE NO. 1
****************************************************
* *
* STAAD.Pro V8i SELECTseries5
* Version 20.07.10.64
* Proprietary Program of
* Bentley Systems, Inc.
* Date= APR 2, 2019
* Time= 22:59:27
* *
* USER ID:
****************************************************
1. STAAD SPACE
INPUT FILE: STEEL COLUMN.STD
2. START JOB INFORMATION
3. ENGINEER DATE 02-APR-19
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT FEET KIP
7. JOINT COORDINATES
8. 1 0 0 0; 2 0 10 0; 3 0 21 0; 4 0 30 0
9. MEMBER INCIDENCES
10. 1 1 2; 2 2 3; 3 3 4
11. DEFINE MATERIAL START
12. ISOTROPIC STEEL
13. E 4.176E+006
14. POISSON 0.3
15. DENSITY 0.489024
16. ALPHA 6E-006
17. DAMP 0.03
18. TYPE STEEL
19. STRENGTH FY 5184 FU 8352 RY 1.5 RT 1.2
20. END DEFINE MATERIAL
21. MEMBER PROPERTY AMERICAN
22. 1 TO 3 TABLE ST HSST6X6X0.25
23. CONSTANTS
24. MATERIAL STEEL ALL
25. SUPPORTS
26. 1 FIXED
27. 2 TO 4 FIXED BUT FY MY
28. DEFINE WIND LOAD
*** NOTE: If any floor diaphragm is present in the model Wind Load definition
should be defined after Floor Diaphragm definition. Otherwise wind
load generation may be unsuccessful during analysis.
29. TYPE 1 WIND 1
30. <! STAAD PRO GENERATED DATA DO NOT MODIFY !!!
31. ASCE-7-2010:PARAMS 110.000 MPH 0 1 3 0 0.000 FT 0.000 FT 0.000 FT 1 -
32. 1 30.000 FT 26.000 FT 14.000 FT 2.000 0.010 0 -
33. 0 0 0 0 0.701 1.000 1.000 0.850 0 -
C:\Users\AECPARVINDER\Dropbox\US PROJECTS\UR801 MIKE BAKSHI 15712 - 72 AVE. WEST, EDMONDS, WASHINGTON\ SWORK\ CALCULAT74S\2
STAAD SPACE
-- PAGE NO. 2
Tuesday, April 02, 2019, 11:00 PM
34. 0 0 0 0.877 0.800 -0.550
35. !> END GENERATED DATA BLOCK
36. INT 0.0207644 0.0207644 0.0209916 0.0212075 0.0214134 0.0216103 0.021799 -
37. 0.0219805 0.0221552 0.0223238 0.0224867 0.0226445 0.0227974 0.0229458 0.02309 -
38. HEIG 0 15 16.1539 17.3077 18.4615 19.6154 20.7692 21.9231 23.0769 -
39. 24.2308 25.3846 26.5385 27.6923 28.8462 30
40. EXP 0.5 JOINT 1 TO 4
41. LOAD 1 LOADTYPE DEAD TITLE LOAD CASE 1
42. SELFWEIGHT Y -1
43. JOINT LOAD
44. 4 FY -2.86
45. 3 FY -4.5
46. 2 FY -5
47. LOAD 2 LOADTYPE LIVE REDUCIBLE TITLE LOAD CASE 2
48. JOINT LOAD
49. 4 FY -3
50. 3 FY -6.5
51. 2 FY -6.2
52. MEMBER LOAD
53. 1 TO 3 UNI GX 0.235
54. LOAD COMB 3 COMBINATION LOAD CASE 3
55. 1 1.25 2 1.5
56. PERFORM ANALYSIS PRINT ALL
P R O B L E M S T A T I S T I C S
-----------------------------------
NUMBER OF JOINTS 4 NUMBER OF MEMBERS 3
NUMBER OF PLATES 0 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 4
SOLVER USED IS THE OUT -OF -CORE BASIC SOLVER
ORIGINAL/FINAL BAND -WIDTH=
TOTAL PRIMARY LOAD CASES =
TOTAL LOAD COMBINATION CASES =
SIZE OF STIFFNESS MATRIX =
REQRD/AVAIL. DISK SPACE =
1/ 1/ 4 DOF
2, TOTAL DEGREES OF FREEDOM =
1 SO FAR.
1 DOUBLE KILO -WORDS
12.0/ 227984.9 MB
6
C:\Users\AECPARVINDER\Dropbox\US PROJECTS\UR801 MIKE BAKSHI 15712 - 72 AVE. WEST,EDMONDS,WASHINGTON\SWORK\CALCULAT7(f5S \ 2
Tuesday, April 02, 2019, 11:00 PM
STAAD SPACE -- PAGE NO. 3
LOADING 1 LOADTYPE DEAD TITLE LOAD CASE 1
SELFWEIGHT Y -1.000
ACTUAL WEIGHT OF THE STRUCTURE = 0.534 KIP
JOINT LOAD - UNIT KIP FEET
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
4 0.00 -2.86 0.00 0.00 0.00 0.00
3 0.00 -4.50 0.00 0.00 0.00 0.00
2 0.00 -5.00 0.00 0.00 0.00 0.00
LOADING 2 LOADTYPE LIVE REDUCIBLE TITLE LOAD CASE 2
JOINT LOAD - UNIT KIP FEET
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
4
0.00
-3.00 0.00
0.00
0.00
0.00
3
0.00
-6.50 0.00
0.00
0.00
0.00
2
0.00
-6.20 0.00
0.00
0.00
0.00
MEMBER
LOAD - UNIT
KIP FEET
MEMBER
UDL
L1 L2 CON
L
LIN1
LIN2
1
0.2350 GX
0.00 10.00
2
0.2350 GX
0.00 11.00
3
0.2350 GX
0.00 9.00
FOR LOADING - 1
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 0.00000E+00-8.89752E-02 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
2 0.00000E+00-5.18685E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
3 0.00000E+00-4.67795E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
4 0.00000E+00-2.94008E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 1
LOADTYPE DEAD TITLE LOAD CASE 1
C:\Users\AECPARVINDER\Dropbox\US PROJECTS\UR801 MIKE BAKSHI 15712 - 72 AVE. WEST,EDMONDS,WASHINGTON\SWORK\CALCULAT7(OS\2
Tuesday, April 02, 2019, 11:00 PM
STAAD SPACE
-- PAGE NO. 4
CENTER OF FORCE BASED ON Y FORCES ONLY (FEET).
(FORCES IN NON -GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)
X = 0.000000000E+00
Y = 0.184822805E+02
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KIP FEET ) SUMMARY (LOADING 1 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = -12.89
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN-
MX= 0.0000000E+00 MY= 0.0000000E+00 MZ= 0.0000000E+00
***TOTAL REACTION LOAD( KIP FEET ) SUMMARY (LOADING 1 )
SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 12.89
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN-
MX= 0.0000000E+00 MY= 0.0000000E+00 MZ= 0.0000000E+00
MAXIMUM DISPLACEMENTS ( INCH /RADIANS) (LOADING 1)
MAXIMUMS AT NODE
X = 0.00000E+00 0
Y = -1.88187E-02 4
Z = 0.00000E+00 0
RX= 0.00000E+00 0
RY= 0.00000E+00 0
RZ= 0.00000E+00 0
EXTERNAL AND INTERNAL JOINT
LOAD SUMMARY ( KIP
FEET )-
JT EXT FX/
EXT FY/
EXT FZ/
EXT MX/
EXT MY/
EXT MZ/
INT FX
INT FY
INT FZ
INT MX
INT MY
INT MZ
SUPPORT=1
1 0.00
-0.09
0.00
0.00
0.00
0.00
0.00
-12.80
0.00
0.00
0.00
0.00 111111
FOR LOADING - 2
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 1.17500E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00-1.95833E+00
2 2.46750E+00-6.20000E+00 0.00000E+00 0.00000E+00 0.00000E+00-4.11250E-01
3 2.35000E+00-6.50000E+00 0.00000E+00 0.00000E+00 0.00000E+00 7.83333E-01
4 1.05750E+00-3.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 1.58625E+00
STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 2
LOADTYPE LIVE REDUCIBLE TITLE LOAD CASE 2
C:\Users\AECPARVINDER\Dropbox\US PROJECTS\UR801 MIKE BAKSHI 15712 - 72 AVE. WEST,EDMONDS,WASHINGTON\SWORK\CALCULAT707S\2
Tuesday, April 02, 2019, 11:00 PM
STAAD SPACE
-- PAGE NO. 5
CENTER OF FORCE BASED ON X FORCES ONLY (FEET).
(FORCES IN NON -GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)
X = 0.000000000E+00
Y = 0.150000006E+02
Z = 0.000000000E+00
CENTER OF FORCE BASED ON Y FORCES ONLY (FEET).
(FORCES IN NON -GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)
X = 0.000000000E+00
Y = 0.183757968E+02
Z = 0.000000000E+00
***TOTAL APPLIED LOAD ( KIP FEET ) SUMMARY (LOADING 2 )
SUMMATION FORCE-X = 7.05
SUMMATION FORCE-Y = -15.70
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN-
MX= 0.00 MY= 0.00 MZ=-105.75
***TOTAL REACTION LOAD( KIP FEET ) SUMMARY (LOADING 2 )
SUMMATION FORCE-X = -7.05
SUMMATION FORCE-Y = 15.70
SUMMATION FORCE-Z = 0.00
SUMMATION OF MOMENTS AROUND THE ORIGIN-
MX= 0.00 MY= 0.00 MZ= 105.75
MAXIMUM DISPLACEMENTS ( INCH /RADIANS) (LOADING 2)
MAXIMUMS AT NODE
X = 0.00000E+00 0
Y = -2.27823E-02 4
Z = 0.00000E+00 0
RX= 0.00000E+00 0
RY= 0.00000E+00 0
RZ= 0.00000E+00 0
EXTERNAL AND INTERNAL JOINT
LOAD SUMMARY ( KIP
FEET )-
JT
EXT FX/
EXT FY/
EXT FZ/
EXT MX/
EXT MY/
EXT MZ/
INT FX
INT FY
INT FZ
INT MX
INT MY
INT MZ
SUPPORT=1
1
1.17
0.00
0.00
0.00
0.00
-1.96
0.00
-15.70
0.00
0.00
0.00
0.00
111111
2
2.47
-6.20
0.00
0.00
0.00
-0.41
0.00
6.20
0.00
0.00
0.00
0.00
101101
3
2.35
-6.50
0.00
0.00
0.00
0.78
0.00
6.50
0.00
0.00
0.00
0.00
101101
4
1.06
-3.00
0.00
0.00
0.00
1.59
0.00
3.00
0.00
0.00
0.00
0.00
101101
C:\Users\AECPARVINDER\Dropbox\US PROJECTS\UR801 MIKE BAKSHI 15712 - 72 AVE. WEST, EDMONDS, WASHINGTON\ SWORK\ CALCULAT7(aS\2
Tuesday, April 02, 2019, 11:00 PM
STAAD SPACE
-- PAGE NO. 6
LOAD COMBINATION NO. 3
COMBINATION LOAD CASE 3
LOADING- 1. 2.
FACTOR - 1.25 1.50
************ END OF DATA FROM INTERNAL STORAGE ************
57. PARAMETER 1
58. CODE AISC UNIFIED 2010
59. CHECK CODE ALL
C:\Users\AECPARVINDER\Dropbox\US PROJECTS\UR801 MIKE BAKSHI 15712 - 72 AVE. WEST,EDMONDS,WASHINGTON\SWORK\CALCULAT7(gS\2
Tuesday, April 02, 2019, 11:00 PM
STAAD SPACE -- PAGE NO. 7
STAAD.PRO CODE CHECKING - (AISC-360-10-LRFD) v1.3a
********************************************
ALL UNITS ARE - KIP INCH (UNLESS OTHERWISE
Noted)
MEMBER TABLE RESULT/
CRITICAL COND/ RATIO/
LOADING/
FX
----------------------------------------------------------------------
----------------------------------------------------------------------
MY
MZ
LOCATION
1 ST HSST6X6X0.25
(AISC
SECTIONS)
PASS
Eq. H1-1a
0.355
3
39.67 C
0.00
35.25
0.00
2 ST HSST6X6X0.25
(AISC
SECTIONS)
PASS
Eq. H1-1b
0.201
3
23.89 C
0.00
42.65
0.00
3 ST HSST6X6X0.25
(AISC
SECTIONS)
PASS
Eq. H1-1b
0.106
3
8.28 C
0.00
28.55
0.00
60. FINISH
*********** END OF THE STAAD.Pro RUN ***********
**** DATE= APR 2,2019 TIME= 22:59:33 ****
C:\Users\AECPARVINDER\Dropbox\US PROJECTS\UR801 MIKE BAKSHI 15712 - 72 AVE. WEST, EDMONDS, WASHINGTON\ SWORK\ CALCULATWS \ 2