BLD2023-1218_Site_Plan_9.29.2023_11.26.09_AM_3812465Equipment Summary Modules: (32) REC 410w Alpha BoB Inverter(s): (32) Enphase IQ8M (240V) Racking: Ironridge XR10 Attachment: S-5-N & S-5-S Clamps Table of Contents: Cover Page Al Site Overview A2 Roof Layout E1 Single Line E2 Electrical Calculations G1 Roof As Built G1.1 Enphase Stringing G2 Electrician As -Built G3 Micro/optimizer map G4 Placards G5 Equipment BOM General Notes: Additional Work: K� Al 0 Site O AIL A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U L Q iI � O o L ro o � 00 ,;I- -0 V o . >Q U N 0 U') n .. V� ry E N Ln -0 LU L M a REVISIONS Rev. #: IDate: _ 1 `� •�` Designed by: Tyler M. Project Manager: Will MacArthur Net Meter (206) 307-1741 Current Date:Sep 19, 2023 Cover Page Modules not to exceed height of existing ridge 36" '611 Building height I -Net Meter -Tap Box Manufactured trusses, -AC Disconnect 24" O.C. -Generation Panel 18' -200 MSP(x2) 1-/ -Combiner Box Attachment Detail Side View (Portrait) VARIES PV MODULE, BY OTHERS IRONRIDGE RAIL 6" (E) STANDING SEAM METAL ROOF S-5! CLAMP (E) ROOF FRAMING (sample) Attachment point layout for array. 48" OC Max. A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U L Q iI O O L O U.) T_.J 00 mid V0 . >Q U rn N V N E Q N Ln -0 LU L M a REVISIONS Rev. #: I Date: Designed by: Tyler M. Project Manager: Will MacArthur (206) 307-1741 Current Date:Sep 19, 2023 Al Site Overview Required Setbacks from Ridge: 36" Maximum Mount Spacing: 48" Roof Type: Metal Seam Roof Slope: g' Array Tilt : Flush Array Azimuth(s): 1100,290° Roof Area: 3593 W Array Area 1429 ft2 Array to Roof Coverage 39% ***Roof Attachments/ Fastners; see pg. G5 Equip. BOM * * * 0 36" "All r B" L Module and Rail Selection Guide REC410AA Pure 40 x 71.7 Mount: S-5-N, S-5-S Clamp Zone "A" 7.9-11.8" Clamp Zone "B" 14.8-19.9" Mods per Row Rail typel+ rail type2 (1)Row, (9)Portrait (4)17' (1)Row, (7)Portrait (4)14' (3)Rows, (1)Landscape (1)14' (3)Rows, (2)Landscape (2)14' 36' �� &xl�I�i A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U L Q iI O p L O U.) ,-a 00 i Ln C%) V . >Q U rn N 0 cn I i ,�-I .. V-,z q '�I-ry E N Ln -0 LU L M a REVISIONS Rev. #: I Date: Designed by: Tyler M. Project Manager: Will MacArthur (206)307-1741 Current Date:SeD 19, 2023 A2 Roof Layout b ---------------- Branch 1 11 modules Branch 2 li modules Branch 3 10 modules Existing PV System Max Output current: 70A System Size DC: 12.76 kW System Size AC: 11.80 kW Module Type: Itek ITE 290W Inverter: Solectria PVI 660OTL Solectria PVI 520OTL 0 Equipment Schedule 20A/2p 20A/2p 20A/2 I � I I CAI I I I I I I I I I I 60A/2p 70A/2p Generation Panel Bus:200A Ref. Category Equipment QTY 1 Modules REC410AA Pure 32 2 Inverters Enphase IQ8M-72-M-US 32 3 Jbox JBox 4 41 Loadcenters Enphase IQ Combiner Panel 80A, 240V 1 Breakers 2p20A 3 6 Disconnect 200A 240V 2 Pole I Heavy Duty, Fuse, Lockable 1 DisconnectFuse FLNR - 175 A Fuses for Disconnect (qty 1 /pole) 2 Monitoring Enphase IQ Envoy Gateway 1 51 LoaclCenters MLO, 200A, 240V, 1ph, Nema 3R, Surface, 4 space (min.) 1 0 Conductor Schedule Supply Side Connection 705.11(A) in a tap box by net meter I I I � I I I I I _ _ _ _ _ _ _ _ _ _ _ _ I I I I L _ _ _ (Existing) #6 GEC L Main Service Panel (1ph 240V Service) Neutral Bar Main Breaker: 200A w/ bonding jumper Bus Rating:200A Located less than 10' from net meter and less than 10' from tap ■=A&RScope `„I' = Existing or A&RSOLAR Others Scope 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT O CONFER ANY RIGHT IN OR LICENSE TO USE IT M OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. 4/0 XHHW-2 (L1 & L2) 2/0 XHHW-2 Service entrance conductors nverter Specs Watts LW-1 Output AC Voltage # of Inverters OCPQ L11ranch Enphase IQ8M-72-M-US 325 1.35 240 32 20 ****N/A**** 0 0 0 0 0 ****N/A**** 0 0 0 0 0 Module Specs Watts w Imp Vmp Voc .1 SC R EC410AA Pure 410 9.61 42.7 49 10.35 Temp. Adjusted 0 0 38.9 52.8 0 Summary Distance (ft) Current @125% Operating Voltage Voltage Drop V. Drop (total) A (2)#12 CU, (1)#6 EGC, Q Cable, AIR 50 18.56A 240V 1.22% 2.38% B (6)#10 CU, (1)#10 EGC, THWN-2, 0.75"EMT(min) 50 18.56A 240V 0.77% C (2)#6 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) 10 54A 240V 0.18% D (2)#6 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) 10 54A 240V 0.18% E (2)2/0 CU, (1)#4 N, (1)#6 EGC, THWN-2, 1.25"EMT(min) 10 155.88A 240V 0.03% U L Q NO O i O 00 Ln U) V o M70 . M >Q U C N 0 LA Ln ,�—I .. V N : E Q N Ln -0 • 0 ,--I LU L M a REVISIONS Rev. #: I Date: General Notes: Utility: SnoPUD Designed by: Tyler M. Project Manager: 1. EGC Where exposed to physical damage will be #6AWG Bare CU Will MacArthur 2. If installing conduit on the roof, maintain greater than 7/8" (206) 307-1741 above the surface 3. NEC 690.12: Rapid Shutdown initiated by loss of Grid or AC Current Date:Sep 19, 2023 Disconnect 4. For supply side taps, a #6 GEC (min.) will be run separately from the disconnect and connected to the grounding electrode E1 Single Line with an irreversible crimp PV Electrical Calculations Inverter Specs Watts (w) Output AC Voltage # of Inverters OCPD Branch Total AC Comb. EGC AC L1 out. A OCPD Enphase IQ8M-72-M-US 325 1.35 240 32 20 43.2 60 #10 Ar ****N/A**** 0 0.00 0 0 0 ****N/A**** 0 0.00 0 0 0 Module Specs at Watts IMP Vmp Voc Isc Temp. Coef V(oc) EGC DC REC410AA Pure 410 9.61 42.7 49 10.35 -0.24 #10 Ma M Temp. Adjusted 38.9 52.8 Optimizer? ***Select*** Equipment En phase IQ8M-72-M-US En phase IQ8M-72-M-US ****N/A**** Mppt Input 1 1 2 1 3 1 1 2 1 3 1 --F-2 3 Module REC410AA Pure REC410AA Pure ****SELECT**** # Modules per String 1 0 0 1 0 0 0 0 0 # Strings 1 0 0 1 0 0 0 0 0 # of Mods per group 1 0 0 1 0 0 0 0 0 # of Mods/inverter 1 1 0 # of Inverters 11 21 0 Total # of Modules 32 I nverter Mppt Input iperage (Imp) loltage (Vmp) < Voltage(DC) ax Amps (DC) Array Specs (Adjusted for Temperature) Enphase IQ8M-72-M-U Enphase IQ8M-72-M-US ****N/A**** 1 2 3 1 2 3 1 2 3 9.61 0.00 0.00 9.61 0.00 0.00 0.00 0.00 0.00 38.9 0.0 0.0 38.9 0.0 0.0 0.0 0.0 0.0 52.8 0.0 0.0 52.8 0.0 0.0 0.0 1 0.0 0.0 10.35 0.00 0.00 10.35 0.00 0.00 0.00 1 0.00 0.00 Max Array Power(STC): 13.12 kW DC Max Continuous AC Power: 10.4kW AC Interconnection Calcs Main Breaker 200 Bus Bar 200 Max PV OCD AI lowed 40 PV OCPD Device Used 200 Tap or Breaker? Tap Site Conditions ASHRAE Site: Seattle Low Temp (°F) 19 High 2%Temp (7) 84 High 0.4% Temp (°F) 91 Ref. Conductor Description Distance AL CU Wire Gauge QTY Phase Neutral Neutral EGC (AWE) Wire Type Conduit Type Min. Conduit 90°C Rating Temp Correct. Fill Derate Derated Am aci 750C Rating Current Operating Voltage (fit Conductors AwG QTY @125% Voltage Drop A Longest Branch to Jbox 50 CU #12 2 N/A N/A #6 QCable AIR N/A 30 1 100% 30.00 25 18.6 1 240 1.22% B Jbox to Combiner 50 CU #10 6 N/A N/A #10 THWN-2 EMT 0.75" 40 1 80% 32.00 35 18.6 240 0.77% C Combiner to Combiner 10 CU #6 2 #8 1 #10 THWN-2 EMT 0.75" 75 1 100% 75.00 65 54.0 240 0.18% D Combiner to Disco 10 CU 2/0 2 #4 1 #6 THWN-2 EMT 1.25" 195 1 100% 195.00 175 155.9 240 0.03% E Disco to Interconnect 10 CU 2/0 2 #4 1 #6 THWN-2 PVC 1.25" 195 1 100% 195.00 175 155.9 240 0.03% F G H J )CVoltage drop 0.00% kCVoltage drop 2.24% Total Voltage Drop: A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. s }+ U L Q L > N L 0 o ro 00 . LO 4 � V o se I . M U >Q U N 0 ) .. U-) U) '� C V N E L M REVISIONS Rev. #: I Date: Designed by: Tyler M. Project Manager: Will MacArthur (206)307-1741 Current Date:Sep 19, 2023 E2 Electrical Calculations Typical Placards A) NEC 2020 690.13 & 691.15 B) NEC 2020 705.12 (13)(3)(2) C) Utility Requirement D) Utility Requirement (Utility -Owned) D) A&R Solar Requirement (Customer - Owned) E) A&R Solar Requirement * if combiner used F) NEC 2020 690.13 (B) I) NEC 2020 690.31 (D)(2) K) NEC 2020 690.13 (B) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SOLAR ELECTRIC PV PANELS SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY L) NEC 2020 690.56 (C) Located on or no more than 3' from the service disconnecting means to which the PV system is connected O) A&R Solar Requirement * if multiple inverters IAWARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM P) NEC 2020 705.12(C) & 690.59 CAUTION:D• NOT ADDITIONAL LOADS IN THIS PANEL R) AHJ Requirement * if combiner used S) NEC 2020 230.85(1) T) NEC 2020 230.85(3) Custom Placards &*41. A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. s PLACARD SPECS QN L Q G) NEC 690.54 N Letter Height: 1/8" L L C:) U) O OUTPUT,MAX AC Maintain 1/4" border 2 Branch of 11 0 -0 a-+ (3)OPERATING • Red / White V In U) O Q G) NEC 690.54 '—I U M -p Letter Height: 1/8" (1) for each PV load U j M N MAX AC • Maintain 1/4" border 3 center, 0 � "6 OPERATING AC V• Red / White Disconnect, ■ ■ }a �j _ .� N O G NEC 690.54 MSP/upstream V � � � ,--I .. E Letter Height: 1/8" •n N ,--I LU MAX AC OUTPUT CURRENT: 13.50 A AC Maintain 1/4" border 1 Branch of 10 0 M . •. Red /White a '� REVISIONS Rev. #: I Date: IDesioned bv: Tvler M. Project Manager: Will MacArthur (206)307-1741 Current Date:Sep 19, 2023 G4 Placards J) NEC 2020 690.56 (C)(2) Category Equipment QTY Modules REC410AA Pure 32 Inverters Enphase IQ8M-72-M-US 32 Jbox JBox 4 Loadcenters Enphase IQ Combiner Panel 80A, 240V 1 Breakers 2p20A 3 Disconnect 200A 240V 2 Pole I Heavy Duty, Fuse, Lockable 1 DisconnectF useFLNR - 175 A Fuses for Disconnect (qty 1 /pole) 2 Monitoring Enphase IQ Envoy Gateway 1 LoadCenters MLO, 200A, 240V, 1ph, Nema 3R, Surface, 4 space (min.) 1 Breakers 2p70A, 2p60A Enphase accessories Misc. Landscape Q cable (6.5' connector spacing) 13 Misc. Portrait Q cable 19 Misc. Terminator Caps 5 S-5-S Mounting IronRidge Racking BOM XR10 Black,14' 6 Universal Module Clamp, Black 18 Stopper Sleeve 30mm 12 Grounding Lug, Low Profile 3 Square -Bolt Bonding Attachment Hardware 27 1/4 x 3/4 Microinverter Bonding Hardware, T-Bolt 6 End Caps, 10 sets(package) XR10 1 S-5-S, Mill (Spacing: 48") 27 L-Feet, Black 27 S-5-N Mounting IronRidge Racking BOM XR10 Black,17' 4 XR10 Black,14' 7 Kit, XR10 Bonded Splice BOSS 4 Universal Module Clamp, Black 48 Stopper Sleeve 30mm 20 Grounding Lug, Low Profile 5 Square -Bolt Bonding Attachment Hardware 51 1/4 x 3/4 Microinverter Bonding Hardware, T-Bolt 19 End Caps, 10 sets(package) XR10 1 S-5-1\11 Mill (Spacing: 4811 ) 51 L-Feet, Black 51 System Weights Racking Weight: 248.1(lbs) Total Weight: 1375.6(lbs) Weight/Attachment: 17.64(I bs) DeadLoad: 2.76(PSF) A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U L Q � NO o i ro� o 00 �Ln�� V o - . >Q U N cn I i ,�-I E .. V N E N Ln -0 • 0 W L M REVISIONS Rev. #: I Date: IDesioned bv: Tvler M. Project Manager: Will MacArthur (206)307-1741 Current Date:SeD 19, 2023 G5 Equipment BOM