Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2023-1211_Manufacturer_Specifications_and_Installation_Instructions_9.28.2023_2.17.25_PM_3810870
SUBMITTAL DATA —WALL MOUNTED MPC018S4S-1 P - MWMC018S4-1 P L ENN CX SINGLE ZONE MINI -SPLIT HEAT PUMP Job: Engineer: Location: Architect: Schedule No.: Date: System Designation: For: ❑ Reference ❑ Approval ❑ Review ❑ Construction Outdoor Unit: MPCO18S4S-1P Indoor Unit: MWMC018S4-1P LENNOX • DC ,nverter &ontrol • Compressor Overcurrent Protection • Base 3 an + eater • Defrost &ontrol Line Set and Elevation Guidelines Maximum Line Set Length ft. (m) Maximum Elevation - Outdoor Unit Below/Above Indoor Unit ft. (m) Liquid Line Set Diameter (in.) Gas Line Set Diameter (in.) Pre -Charged (ft.) Additional Charge of Refrigerant (oz/ft.) Compressor — Twelve year limited warranty* All other covered components - Twelve year limited warranty* *Product registration required • Pre -Heat Function • Auto Restart • Three Selectable Fan Speeds • Flare Connections • LED Readout • Multi -Refrigerant Outlet • Wireless Remote Included 98 (30) 66 (20) 1/4 1/2 15 0.16 Non -Programmable Controller (MOSTAT61 Q-1) Programmable Controller (MOSTAT64Q-2) ®AQ LUW C US © MEMBER COMPANY Intertek NOTE — Due to Lennox' ongoing commitment to quality, Specifications, Ratings, and Dimensions are subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 495924 (202204) ©2022 Lennox Industries, Inc. SUBMITTAL DATA -WALL MOUNTED L ENVNDX PERFORMANCE Coolinq Capacity (Max/Min) (Btu/h)' EER SEER Heating Capacity (Max/Min) (Btu/h)' HSPF Outdoor Fan Total Air Volume (CFM) Ambient Temperature Operating Range Cooling Heating ELECTRICAL DATA Power Supply (V/Hz/q)) Minimum Circuit Ampacity (A) Maximum Overcurrent Protection (A) Outdoor Fan Motor RLA (A) Compressor RLA (A) No. of Compressors 13-3/4 (349) 15 (381) 1/2 (13) I~ 18,000 (19,300/2,000) 12.5 22.6 19,000 (21,000/6,200) 12.0 1,765 2-7/8 (73) TOP VIEW FRONT VIEW 35-1/4 (895) i-1/8 (664 35 (889) -1YF - 122°F -1YF - 86°F 208-230/60/1 17 25 0.76 12 1 2-7/8 (73) MPC018S4S-1 P - MWMC018S4-1 P SINGLE ZONE MINI -SPLIT HEAT PUMP GENERAL DATA Connection Ratio (%) Max. # of Indoor Units Sound Data (dBA) - Cooling/Heating Refrigerant type Factory refrigerant charge DIMENSIONS Unit Dimensions (in) Shipping Weight (lb) Net Weight (lb) NOTES 100% 1 unit 58/58 R-410A 3 lbs. 8 oz. Height 26-1/2 Width 37-5/8 Depth 15 102 95 1. Cooling and Heating Capacity data is rated at the following conditions: Cooling: 80°FDB / 67°FWB Indoor, 95°FDB Outdoor Heating: 70°FDB Indoor, 47°FDB / 43°FWB Outdoor 12-3/4 (324) LIQUID VALVE IE VE 37-5/8 955) NOTE — Due to Lennox' ongoing commitment to quality, Specifications, Ratings, and Dimensions are subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 495924 (202204) ©2022 Lennox Industries, Inc. LENNOX __ SUBMITTAL DATA -WALL MOUNTED MPC018S4S-1 P - MWMC018S4-1 P SINGLE ZONE MINI -SPLIT HEAT PUMP PERFORMANCE DIMENSIONS AIR FLOW (CFM) High 524 Unit Dimensions (in) Height 12-1/2 Medium 376 Width 40 Low 306 Depth 9-1/2 SOUND PRESSURE (dBA) High 46.5 Shipping Weight (lb) 36 Medium 43 Net Weight (lb) 27 Low 32.5 NOTES ELECTRICAL DATA Power Supply (V/Hz/q)) Supplied by ODU 1. Cooling and Heating Capacity data is rated at the following conditions: Rated Load Amps (RLA) 0.13 Cooling: 80°FDB / 67°FWB Indoor, 95°FDB Outdoor Power Output (W) 30 Heating: 70°FDB Indoor, 47°FDB / 43°FWB Outdoor (241) SIDE VIEW An FRONT VIEW BOTTOM VIEW (318) NOTE — Due to Lennox' ongoing commitment to quality, Specifications, Ratings, and Dimensions are subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 495924 (202204) ©2022 Lennox Industries, Inc. SUBMITTAL DATA —WALL MOUNTED MPC012S4S-1 P — MWMC012S4-1 P L ENN CX SINGLE ZONE MINI -SPLIT HEAT PUMP Job: Engineer: Location: Architect: Schedule No.: Date: System Designation: For: ❑ Reference ❑ Approval ❑ Review ❑ Construction Outdoor Unit: MPC012S4S-1P Indoor Unit: MWMC012S4-1P LENNOX • DC ,nverter &ontrol • Compressor Overcurrent Protection • Base 3 an + eater • Defrost &ontrol Line Set and Elevation Guidelines Maximum Line Set Length ft. (m) Maximum Elevation - Outdoor Unit Below/Above Indoor Unit ft. (m) Liquid Line Set Diameter (in.) Gas Line Set Diameter (in.) Pre -Charged (ft.) Additional Charge of Refrigerant (oz/ft.) Compressor — Twelve year limited warranty* All other covered components - Twelve year limited warranty* *Product registration required • Pre -Heat Function • Auto Restart • Three Selectable Fan Speeds • Flare Connections • LED Readout • Multi -Refrigerant Outlet • Wireless Remote Included Non -Programmable Controller (MOSTAT61 Q-1) Programmable Controller (MOSTAT64Q-2) ®AQ LUW ComUS © MEMBER COMPANY Intertek 15 0.16 NOTE — Due to Lennox' ongoing commitment to quality, Specifications, Ratings, and Dimensions are subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 495923 (202204) ©2022 Lennox Industries, Inc. SUBMITTAL DATA -WALL MOUNTED LENNOX .0 1--- PERFORMANCE Cooling Capacity (Max/Min) (Btu/h)1 EER SEER Heating Capacity (Max/Min) (Btu/h)1 HSPF Outdoor Fan Total Air Volume (CFM) Ambient Temperature Operating Range Cooling Heating ELECTRICAL DATA Power Supply (V/Hz/q)) Minimum Circuit Ampacity (A) Maximum Overcurrent Protection (A) Outdoor Fan Motor RLA (A) Compressor RLA (A) No. of Compressors DRAIN HOLE 12,000 (13,300/3,600) 13.7 23.2 12,000 (13,500/4,500) 13.2 1,295 TOP VIEW 30-7/8 (784) 17-3/4 (451) 30-1 /8 (765) -13°F - 122°F -1WF - 86°F 208-230/60/1 13 15 0.4 6.4 1 MPC012S4S-1 P - MWMC012S4-1 P SINGLE ZONE MINI -SPLIT HEAT PUMP GENERAL DATA Connection Ratio (%) Max. # of Indoor Units Sound Data (dBA) - Cooling/Heating Refrigerant type Factory refrigerant charge DIMENSIONS Unit Dimensions (in) Shipping Weight (lb) Net Weight (lb) NOTES 100% 1 unit 53.5/53.5 R-410A 2 lbs. 6 oz. Height 21-7/8 Width 32-7/8 Depth 12-3/8 69 64 1. Cooling and Heating Capacity data is rated at the following conditions: Cooling: 80°FDB / 67°FWB Indoor, 95°FDB Outdoor Heating: 70°FDB Indoor, 47°FDB / 43°FWB Outdoor 21 GAS VALVE (QUID VALVE 60) 32-7/8 (835) SIDE VIEW FRONT VIEW NOTE — Due to Lennox' ongoing commitment to quality, Specifications, Ratings, and Dimensions are subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 495923 (202204) ©2022 Lennox Industries, Inc. LENNOX __ SUBMITTAL DATA -WALL MOUNTED MPC012S4S-1 P - MWMC012S4-1 P SINGLE ZONE MINI -SPLIT HEAT PUMP PERFORMANCE DIMENSIONS AIR FLOW (CFM) High 335 Unit Dimensions (in) Height 11-3/4 Medium 230 Width 33-3/8 Low 176 Depth 9 SOUND PRESSURE (dBA) High 36 Shipping Weight (lb) Medium 33.5 Net Weight (lb) Low 22.5 NOTES ELECTRICAL DATA Power Supply (V/Hz/q)) Supplied by ODU 1. Cooling and Heating Capacity data is rated at the following conditions: Rated Load Amps (RLA) 0.25 Cooling: 80°FDB / 67°FWB Indoor, 95°FDB Outdoor Power Output (W) 20 Heating: 70°FDB Indoor, 47°FDB / 43°FWB Outdoor (229) SIDE VIEW 14Q_14/R FRONT VIEW BOTTOM VIEW (298) NOTE — Due to Lennox' ongoing commitment to quality, Specifications, Ratings, and Dimensions are subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 495923 (202204) ©2022 Lennox Industries, Inc.