APPROVED DEFSUB 9 BLD2018-1622+GENERATOR_PLANS+1.10.2022_4.08.58_PM+2613173GENERAL NOTES 6A5T-IN-FLA6E GONGRETE DEFINITION. THE TERM "ENGINEER" AS USED IN THESE STRUCTURAL DOCUMENTS SHALL MEAN GARY KOPCZYN5KI 8 CO., INC. P.5. GOVERNING CODE. THE 2015 EDITION OF THE "INTERNATIONAL BUILDING CODE" (IBG), AS ADOPTED AND AMENDED BY CITY OF EPMON05 SHALL GOVERN DE5I61N AND CONSTRUCTION, REFERENCE STANDARDS. REFERENCE TO A5TM AND OTHER 5TANDARD5 SHALL MEAN THE LATEST EDITION AS OF THE BID DATE OF OWNER -CONTRACTOR AGREEMENT, WHICHEVER 15 LATER, UNLE55 NOTED IN THESE DOCUMENTS OR DE5I6NATED BY THE GOVERNING CODE. PRAWINC75 BY OTHERS. REFER TO ARCHITECTURAL AND OTHER DRAWIN65 FOR ELEVATIONS, SLOPES, DEPRE55ION5, NON -BEARING WALL5, FASCIA, ELEVATORS, STAIRS, CURBS, DRAINS, DUCTS, CHASES, PIPES, RAILING5, WATERPROOFING, FINI5HE5, ETC. OMI55ION5/GONFLIGT5.IN CASE OF DISCREPANCIES BETWEEN THE PLANS, SPECIFICATIONS, NOTES ON THI5 SHEET, REFERENCE STANDARDS, GOVERNING CODE OR ANY OTHER INFORMATION PERTINENT TO THE PROJECT, WHETHER WRITTEN OR VERBAL, THE MORE 5TRIN61ENT REQUIREMENTS SHALL GOVERN. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK. 5ITE VERIFICATION. THE CONTRACTOR SHALL VERIFY ALL DIMEN5ION5 AND CONDITIONS AT THE SITE. 5ITE SAFETY. THE CONTRACTOR 15 RESPONSIBLE FOR SAFETY AT THE 5ITE AND FOR THE 5TREN6TH AND STABILITY OF ALL PARTLY COMPLETED STRUCTURE. CONFORM TO M05T CURRENT VERSION OF A5GE 31 "DE5I67N LOADS ON STRUCTURES DURING CONSTRUCTION". LOAD LIMITS. LOADS ON THE STRUCTURE SHALL NOT EXCEED THE DE5I6IN LOADS 5HOWN UNDER "DE5I6N CRITERIA". CONSTRUCTION MEANS AND METHODS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTION MEAN5/METH005 AND FOR VERIFYING STRUCTURAL CAPACITY PRIOR TO APPLYING CONSTRUCTION LOADING. ALTERNATES. ALTERNATES FOR SPECIFIED ITEMS MAY BE SUBMITTED TO THE ENGINEER FOR REVIEW. ENGINEER MAY REQUEST PAYMENT FOR REVIEWING THESE SUBMITTALS. SPECIAL INSPECTION. GARY KOPCZYN5KI AND GO. INC. P.5. I5 NOT THE SPECIAL INSPECTOR SPECIAL INSPECTION BY OTHERS 15 REQUIRED IN ACCORDANCE WITH CHAPTER 11 OF THE INTERNATIONAL BUILDING CODE, AS ADOPTED AND AMENDED BY CITY OF BELLEVUE FOR THE FOLLOWING ITEMS: ANCHORS IN CONCRETE DE5I5N CRITERIA GRAVITY LOADS. GENERATOR - 5,100 Ib5 SEISMIC LOADS (ARCHITE( TURAL AND MECHANICAL COMPONENTS) SEISMIC DE5I6N FORGE: FF, = 0.4aF5D51NP (1 + 2(z/h)) / (R / 1 ) FP = 1.65D5IP WP (UPPER LIMIT) FP = 0.35D5IP WP (LOWER LIMIT) WHERE 5D5 = 0.84 ap = 1.0 (6ENERA70R5, BATTERIES, INVERTERS, MOTORS...) RP = 2.5 (6ENERA70R5, BATTERIES, INVERTERS, MOTORS...) Ip = 1.5 WIND LOAD5 110 MPH BASIC WIND SPEED (3-5EGOND GU5T, A5GE 1 SECT 26.5) WIND IMPORTANCE FACTOR IN = 1.15 (A5GE 1 TABLE 1.5-2) WIND EXP05URE CATEGORY B (A5GE 1 SECT 26.1) ELEMENTS AND COMPONENTS: DE5I6N WIND PRE55URE FOR DETERMINING FORGES ON ELEMENTS AND COMPONENTS OF THE STRUCTURAL SHALL BE PER IBC SECTION 160g. A55REVIATION5 GENERAL L ANGLE MAX @ AT MECH'L ANCH ANCHOR MFR ARCH ARCHITECT MIN MI5G BOT BOTTOM BM BEAM (N) NT5 (. GENTERLINE NO OR ` G CHANNEL I GLR CLEAR oG GOL COLUMN OPNG GONG CONCRETE OFF CONN CONNECTION GON5T CONSTRUCTION E GONT CONTINUOUS PENE P5F d DEPTH P5I DEMO DEMOLISH DETAIL DETAIL REF PIA DIAMETER REINF DIMENSION DIMENSION REQ'D DWL DOWEL 50G SECT (E) or EXI5T EXI5TING 5IM EN EACH WAY SPEC EA EACH 5TD EMBED EMBEDMENT 5TRUCT ENO ENGINEER t FON FOUNDATION t 6 b or t/b FTG FOOTING TO TYP GA GAGE OR GAUGE GRND GROUND UNO HT HEIGHT OR HIGH VERT HORIZ HORIZONTAL w/ IN INCH w/o w LES POUNDS MT LOG LOCATION I LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS NEA NOT TO SCALE NUMBER ON CENTER OPENING OFF05ITE PLATE PENETRATE OR PENETRATION POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH REFERENCE REINFORCING (MENT) REQUIRED SLAB -ON -GRADE SECTION 5IMILAR SPECIFICATION 5TANDARD STRUCTURAL OR STRUCTURE TOP TOP AND BOTTOM TOP OF TYPICAL UNLE55 NOTED OTHERAI5E VERTICAL WITH WITHOUT WIDTH WEIGHT REFERENCE STANDARDS. CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF THE FOLLOWING CODES, SPECIFICATIONS, AND STANDARDS, EXCEPT AS MODIFIED BELOW: AGI 501"STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE" AGI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" AGI 304 "GUIDE FOR MEA5URING, MIXIN(5, TRANSPORTING, AND PLACING CONCRETE" AGI 511 "GUIDE FOR CONCRETE INSPECTION" AGI 116 "CEMENT AND CONCRETE TERMINOLOGY" AGI 111 "STANDARD SPECIFICATION FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS" A COPY OF AGI 5P-15 "FIELD REFERENCE MANUAL", WHICH INCLUDES AGI 301, SHALL BE KEPT IN THE CONTRAGTOR'5 FIELD OFFICE AT ALL TIMES. MATERIALS. CEMENT ......................................... A5TM G150,C5g5 'AGGREGATE5.....................................A5TM C33 ADMIXTURES.....................................A5TM G260,G4g4 AND G1011 WATER..........................................A5TM C1602 ••FLY ASH.........................................A5TM G615,CLASS F OR G GROUND GRANULATED BLA5T-FURNACE SLAG (505) ..... A5TM GgBg AG6REGATE5 WHICH EXHIBIT DELETERIOUS ACTIVITY WHEN EVALUATED IN ACCORDANCE WITH A5TM G33 APPENDIX X 1, "METHODS FOR EVALUATING POTENTIAL REACTIVITY OF AN AGGREGATE", SHALL NOT BE USED. LOCAL A66RE6ATE5 NOT GOMPLYING WITH A5TM G33 THAT HAVE BEEN 5HOWN BY SPECIAL TESTS OR ACTUAL SERVICE TO PRODUCE CONCRETE OF ADEQUATE 5TRENGTH AND DURABILITY MAY BE USED WHEN ACCEPTABLE TO ENGINEER. SAND EQUIVALENT FOR FINE AGGREGATE SHALL NOT EXCEED 15. •• MAXIMUM L055 ON IGNITION SHALL BE 1%. 656585 SHALL BE GRADE 100 OR 120. MIX SPECIFICATIONS. COMP MAX MINIMUM FLY 5TRENGTH TEST AGE AGGR MAX W/GM AIR A5H/GGB5 MIX (P5I) (DAYS) 5IZE RATIO CONTENT (% OF CM) NOTES GENERATOR FOUNDATION 4000 25 1" - 5.50% - - MIX DE5IGN. MIXES SHALL MEET OR EXCEED EACH REQUIREMENT SPECIFIED. WHERE BOTH 5TREN65TH AND MAXIMUM WATER/GEMENTITIOU5 RATIO ARE SPECIFIED, THE M05T 5TRINGENT SHALL APPLY. FOR EXAMPLE, MAXIMUM WATER/CEMENTITIOU5 RATIO MIGHT RESULT IN A 5TRENGTH GREATER THAN THE MINIMUM SPECIFIED. LIKEWISE, A LOWER WATER/GEMENTITIOU5 RATIO THAN SPECIFIED MAY BE REQUIRED IN ORDER TO ACHIEVE THE REQUIRED 5TREN6TH. WATER/CEMENTITIOU5 RATIO.W/GM RATIO SHALL BE BASED ON TOTAL CEMENTITIOU5 MATERIAL INGLUDING CEMENT AND POZZOLAN5 SUCH A5 FLY ASH, SILICA FUME, AND 57665. AIR CONTENT. SPECIFIED VALUES ARE TOTAL AIR, INGLUDING ENTRAPPED AND ENTRAINED. TOLERANCE FOR AIR CONTENT SHALL BE t 1 1/2016. TE5TING SHALL CONFORM TO A5TM C231 AND G113. THE AVERAGE OF ALL TESTS TAKEN SHALL EQUAL OR EXCEED THE SPECIFIED VALUE. TESTING SHALL BE PERFORMED AT THE POINT OF DELIVERY. 5HRINKAGE. PERFORM 5HRINKA6E TESTS IN ACCORDANCE WITH A5TM C151 MODIFIED A5 FOLLOWS. ALL MEASUREMENTS SHALL BE RECORDED AND SUBMITTED WITH LABORATORY REPORT TO ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION. TE5TIN6 TO BE PERFORMED BY A CERTIFIED LAB. REMOVE SPECIMENS FROM MOLDS AT 23 HOURS t 1 HOUR. 5UBMER6E SPECIMENS IMMEDIATELY IN LIME-5ATURATED WATER AT 131 F t 3° F. REMOVE SPECIMENS FROM WATER AT 30 MINUTES AND MEASURE THE INITIAL LENGTH5. IMMEDIATELY RE5UBMERGE IN LIME-5ATURATED WATER AT 131 F t 3° F FOR 1 DAYS. REMOVE SPECIMENS PERMANENTLY FROM WATER AT 1 DAYS AND MEASURE LENGTH5. STORE SPECIMENS AT 50% t 4% RELATIVE HUMIDITY, AND 13' F t 3° F. MEASURE SPECIMENS 1, 14, 21, AND 25 DAYS AFTER THE 1 DAY WATER CURE. 28 DAY MEASUREMENTS (35 DAYS TOTAL INCLUDING THE 1 DAY WATER CURE) SHALL BE LE55 THAN THE SPECIFIED 5HRINKAGE LIMIT. z INITIAL LENGTH Q rL x x w z w ko >_ i J Q Q Q Q Q w w LU ZN c`Av m �C m V Ll V K: z z � I H 43 " UA UA CURE ALTERNATIVELY, CONFORM TO THE FOLLOWING MAXIMUM ALLOWABLE WATER CONTENT IN LIEU OF 5HRINKAGE TE5TIN6. FOR INTERMEDIATE VALUES, USE LINEAR INTERPOLATION. MAXIMUM ALLOWABLE WATER CONTENT SHALL BE TOTAL WATER IN THE MIX AT TIME OF PLACING, INGLUDING WATER ADDED AT THE SITE. FOR SPECIFIED 26 DAY 5HRINKAGE LIMITS BELOW .030%, A 5HRINKAGE REDUGING ADMIXTURE 15 REQUIRED. MAXIMUM ALLOWABLE SPECIFIED 26 DAY WATER CONTENT 5HRINKAGE LIMIT (%) (LES. / CUBIC YARD) .035.....................................235 .040.....................................245 .045.....................................255 MIX DE5IGN SUBMITTALS. SUBMIT A DE5I6N FOR EACH CONCRETE MIX TO THE ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION. CONFORM TO GBC SECTION N05. DATA SUBMITTED FOR REVIEW SHALL ACCURATELY REFLECT FROP05ED MIX. SLUMP. THE SLUMP REQUIRED FOR PROPER PLACEMENT SHALL BE DETERMINED BY THE CONTRACTOR AND SUPPLIER AND INCLUDED IN THE MIX DE5IGN SUBMITTALS. ACCEPTANCE OF PROP05ED SLUMP SHALL BE OBTAINED FROM THE ENGINEER PRIOR TO CONSTRUCTION. SLUMP SHALL CONFORM TO A5TM C1602 AND MEET THE FOLLOWING TOLERANCES: SLUMP TOLERANCE 2" AND LE55 ................... t 1/2" MORE THAN 2" THRU 4......... .... t 1" MORE THAN 4.................... t 1 1/2" EMBEDDED ITEMS. VERIFY LOCATION OF EMBEDDED ITEMS WITH 5UPPLIER'5 OR DE5I6N CONSULTANT'S DRAWINGS BEFORE PLACING CONCRETE. VERIFY WITH ENGINEER THAT THE LOCATION OF EMBEDDED ITEMS DE5I6NED BY OTHERS I5 ACCEPTABLE BEFORE PLACING CONCRETE. MIXING, TRAN5PORTING AND PLACING. CONCRETE SHALL BE BATGHED, MIXED, TRAN5PORTED AND PLACED IN ACCORDANCE WITH AGI 301 SECTIONS 4 $ 5, AND AGI 304. EACH TRUCK SHALL HAVE A TICKET SHOWING ACTUAL BATCH WEIGHTS OF MATERIALS IN ADDITION TO THE MAXIMUM AMOUNT OF WATER WHICH MAY BE ADDED AT THE SITE. THE TOTAL WATER IN THE MIX AT THE TIME OF PLACING, INCLUDING WATER ADDED AT THE SITE, SHALL NOT EXCEED THE AMOUNT PREAPPROVED IN THE MIX DE5I6N. GURING. CONFORM TO AGI 306, STANDARD SPECIFIGATION FOR CURING CONCRETE, AGI 302, GUIDE TO CONCRETE FLOOR AND SLAB CONSTRUCTION AND AGI 301, SECTION 5. IMPLEMENT GURING PROCEDURES IMMEDIATELY TO MAINTAIN CONCRETE IN A M015T CONDITION AFTER PLACEMENT. LIQUID MEMBRANE -FORMING CURING COMPOUNDS SHALL CONFORM TO A5TM G30g TYPE 1-0. CURING COMPOUNDS APPLIED TO SURFACES INTENDED TO RECEIVE FLOOR COVERING5, PROTECTIVE COATIN655 OR SEALERS, SHALL BE COMPATIBLE WITH TH05E PRODUCTS. APPLY COMPOUNDS IN ACCORDANCE WITH MANUFAGTURER'5 RECOMMENDATION5. POLYETHYLENE 5HEETING AND BURLAP -POLYETHYLENE SHEETING SHALL CONFORM TO A5IM G111. PROVIDE GURING A5 FOLLOW5: L CONFORM TO A5IM C111. PROVIDE GURING AS FOLLOWS: GURING LOCATION C1 GENERATOR FOUNDATION CURING DEFINITION C1 ... IMMEDIATELY AFTER 5GREEDING CONCRETE, APPLY AN EVAPORATIVE REDUCER TO ALL EXP05EP SURFACES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. IMMEDIATELY AFTER FINAL FINI5HING, APPLY LIQUID MEMBRANE -FORMING CURING COMPOUND TO ALL EXP05EP SURFACES. THE COVERAGE RATE SHALL NOT EXCEED 200 SQUARE FEET PER GALLON. SUBMIT WRITTEN PROCEDURE, INGLUDING PROP05EP EVAPORATIVE REDUCER AND CURING COMPOUND SPECIFICATIONS TO ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION. WEATHER CONDITIONS. CONTRACTOR SHALL MAKE APPROPRIATE MODIFICATIONS TO MIXING, TRAN5PORTIN65, PLACING AND CURING PROGEDURE5 DURING PERIODS OF HOT, GOLD OR AINDY WEATHER IN ACCORDANCE WITH AGI 301. FORMWORK. CONFORM TO AGI 301, SECTION 2. SUBMIT PROP05ED FORMWORK DRAAING5, INGLUDING RE5HORING WHEN REQUIRED, TO THE ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION. TE5TING. TE5TIN6 SHALL CONFORM TO THE FOLLOWING: MAKE ONE TEST FOR EACH 150 GU YO, OR 5,000 50. FT. OF SURFACE AREA, FOR EACH MIX PLACED EACH DAY. A "TE57 SHALL BE THE AVERAGE 5TREN(5TH5 OF TWO 6"x12" OR THREE 4"x8" CYLINDERS MADE FROM THE SAME SAMPLE AND TESTED AT THE SPECIFIED AGE. ADDITIONAL CYLINDERS MAY BE MADE FOR INFORMATION FOR P05T-TEN5I0NIN6, FORM REMOVAL, 5TREN65TH DEVELOPMENT OR OTHER PURPOSES. CONCRETE 15 ACCEPTABLE IF 1) NO TEST FALLS MORE THAN 500 P5I BELOW THE SPECIFIED 5TRENGTH AND 2) THE AVERAGE OF ANY 3 CONSECUTIVE TE5T5 DOES NOT FALL BELOW THE SPECIFIED 5TREN65TH. CONCRETE NOT MEETING THE ABOVE CRITERIA MAY BE SUBJECT TO FURTHER TE5TING OR REMOVAL AT CONTRAGTOR'5 EXPENSE. THE ENGINEER MAY REQUEST PAYMENT FOR REVIEWING THE ADEQUACY OF THE CONCRETE IN QUESTION. 10" GONG BASEMENT WALL 8" GONG SLAB w/ THICKENED E065E5 LEVEL P1 PARTIAL FOUNDATION PLAN (GENERATOR) �No rt 5HEET NOTE5: 1. FIELD VERIFY ALL CONDITIONS 5HOWN. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH FABRICATION OF MATERIALS OR CONSTRUCTION. 2. REFERENCE THE FOLLOWING SHEET SERIES: 50. GENERAL NOTES AND DE5I6N CRITERIA 50.1 TYPICAL REBAR DETAILS 51. 30 VIEW5 52. FRAMING AND REINFORCING PLANS 53. FOUNDATION SECTIONS AND DETAILS 54. SHEAR WALL ELEVATIONS AND SECTIONS 55. COLUMN ELEVATIONS AND SECTIONS 56. BEAM ELEVATIONS AND SECTIONS 51. TYP CONCRETE, PT, AND GMU DETAILS 58. TYPICAL STEEL SECTION AND DETAILS Sq. TYPICAL WOOD FRAMING DETAILS 3. ALL STEEL EXP05ED TO WEATHER SHALL BE HOT DIPPED GALVANIZED. CITY OF EDMONDS BUILDING DIVISION APPROVED PLAN (6)1/8" V HILTI HY200 + — HA5-R 316 55 ROD (MIN) w/ MIN EMBED 3 1/2" AROUND PERIMETER - FILL EVERY OTHER HOLE 1/2" RADIUS, TYP GENERATOR BY OTHERS (MAX TOTAL WEIGHT = 5,100 Ib5) 8" GONG SLAB w/ #5t/b @ 18"oc EW FIELD VFY (2) #5 GONT, TYP BLD2018-1622 DEF SUBMITTAL 9 stud' IC,MENG STRAZZARA ARCHITECTURE PLANNING CONSULTING 2001 WESTERN AVE SUITE 200 Seattle, WA USA 98101 206 587 3797 tel 206 587 0588 www.studioms.com STRUCTURAL ENGINEERS Cary Kopczynski & Company 10500 NE 8th Street, Ste 800 Bellevue, WA 98004-4351 Phone: (425) 455-2144 www.ckcps.com Goodman Real Estate TITLE HWY 99 EDMONDS 23400 HWY 99 EDMONDS, WA, 98026 STAMP EXPIRES JUNE 20, 2022 KEY PLAN THE DESIGN AND CONCEPTS SHOWN HEREIN ARE THE PROPERTY OF CKC INC. THEY MAY NOT BE USED OR COPIED IN WHOLE OR PART WITHOUT THE WRITTEN CONSENT OF CKC INC. PROJECT NUMBER 1853.G No Issue/Revision Date PERMIT 108.13.2021 APPROVAL BY: DRAWN BY: BL CHECKED BY: JK SHEET CONTENTS LEVEL P1 PARTIAL FOUNDATION PLAN GENERATOR FOUNDATION 1" = 1'-O" RECEIVED Jan 10 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NUMBER S200OG