Loading...
APPROVED DEF SUB 16 BLD2018-1622+PERIMETER GUARDRAILS +6.5.2022_3.05.16_PM+2912500RECEIVED DEF. SUB.16- RECEIVED BY CKC Jun 062022 PERMIMITER May 16,2022 GRE Construction LLC CITY OFEDMONDS GUARDRAILS Project: cnst7829 Edmonds 99 DEVELOPMENT SERVICES 2801 Alaskan Way Suite 310 DEPARTMENT 23400 Highway 99 Seattle, Washington 98121 Edmonds, Washington 98026 P: (206) 448-0259 BLD2018-1622 Submittal #05 1100-12.0 - Perimeter Guardrails 05 1100 - Structural and Misc. Steel Fabrication Revision 0 Submittal Manager Ben Lek (GRE Construction LLC) Status Open Date Created May 16, 2022 Issue Date May 16, 2022 Spec Section 05 1100 - Structural and Misc. Steel Fabrication Responsible Wintersky Inc Received From Rachael Wesley (Wintersky Inc) Contractor Received Date May 10, 2022 Submit By May 20, 2022 Final Due Date May 20, 2022 Lead Time Cost Code Location Type Shop Drawing Approvers Rachel Buob (CKC Structural Engineers), Lukas Shu (Studio Meng Strazzara) Ball in Court Rachel Buob (CKC Structural Engineers), Lukas Shu (Studio Meng Strazzara) Distribution Victor Vo (GRE Construction LLC), Paul Mandish (GRE Construction LLC), Rob Kralis (GRE Construction LLC), Joel Kipple (CKC Structural Engineers), Rachel Buob (CKC Structural Engineers) Description Perimeter guardrail assemblies. Submittal Workflow Name General Information Attachments Rachel Buob Lukas Shu Sent Date Due Date Returned Date Response I Attachments May 16, 2022 May 20, 2022 May 20, 2022 Pending Pending PLEASE SEE NOTES CHANGING DIMENSION FROM 3 7/8" TO 31/2". LUKAS SHU - SMS - 5/19/2022 06/16/2022 E & Ca'i CITY OF EDMONDS BUILDING DIVISION APPROVED PLAN ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE GRE Construction LLC Page 1 of 1 99 Edmonds HR calcs 050922.pdf Submittal Review for Elements Designed by Others VNO EXCEPTION TAKEN ❑ REVISE AND RESUBMIT ❑ SUBMIT SPECIFIED ITEMS ❑ MAKE CORRECTIONS NOTED ma ❑ REJECTED STRUCTURAL ENGINEERS ❑ NOT REVIEWED ANY ACTION NOTED ABOVE IS SUBJECT TO THE REQUIREMENTS OF THE PROJECT PLANS AND SPECIFICATIONS. CKC IS ENTITLED TO RELY ON THE COMPLETENESS AND ACCUFlACY OF ALL INFORMATION IN THIS SUBMITTAL. OUR REVIEW WAS ONLY TO CHECK FOR GENERAL COMPATIBILITY WITH THE DESIGN INDICATED IN DOCUMENTS PREPARED BY CKC. IT WAS NOT PERFORMED FOR THE PURPOSE OF DETERMINING DESIGN ADEQUACY, SUITABILITY, OR COMPLETENESS FOR THE SUBMITTED ELEMENTS, OR FOR CHECKING DESIGN CALCULATIONS OR DESIGN ASSUMPTIONS. CKC'$ REVIEW DOES NOT RELIEVE OTHER PARTIES FROM RESPONSIBILITY FOR ADEQUACY, ACCURACY, AND COMPLETENESS OF DESIGN OF THE SUBMITTED ELEMENTS, INCLUDING ATTACHMENTS; CORRECTNESS OF DIMENSIONS AND QUANTITIES; VERIFICATION OF PHYSICAL INTER -RELATION OF ELEMENTS; AND CONSTRUCTION PROCEDURES, TECHNIQUES AND SEQUENCES. By JK DATE 5/18/2022 CKC Notes for Entire SubmKtal: -Stamp applies to all sheets of this submiHal. - Review is only for loads applied to the shell structure and general conformance with the CKC structural drawings. - Dimensions and elevations structurally acceptable as shown unless noted otherwise. Architect to provide review comments for dimensions and elevations where required. -Architect to provide review comments for finishes and weatherproofing. POST -INSTALLED ANCHORS IN CONCRETE DECKS: SCAN CONCRETE SLAB PRIOR TO INSTALLATION OF POST -INSTALLED ANCHORS TO LOCATE AND AVOID PT TENDONS AND REINFORCING BAR. HOLD ANCHORS 2" CLEAR OF ALL PT TENDONS AND 1" CLEAR OF ALL BAR. IN NO CASE SHALL PT TENDONS OR REINFORCING BAR BE DAMAGED, NOTIFY CKC IMMEDIATELY OF ALL NONCONFORMANCE. sliderule engineering works, llc Edmonds 99 - Handrail Edmonds, Washington Project Engineer: Andrew L. Herrick, P.E. - _- Sliderule Engineering Works, LLC 227 `E' Street Southeast Auburn, Washington 98002 (206)380-0732 Design Criteria: 2018 International Building Code 50 plf or 200# point load (residential handrail) Lateral Force: The seismic increase to the existing building is negligible (less than 1 % of total bldg) Use: All aluminum shapes shall be 6061-T6, Fy= 35ksi, E = 10,000ksi Aluminum Welding use: 4043 weld material Stainless Steel A-307 (min) bolts at connections at metal to metal connections All field welding shall be by WABO certified welder and be reviewed by special inspector. SS connectors at aluminum Hilti Kwik Bolt TZ per ESR-1917, install per manufacturer's specifications r 227'e' street southeast, auburn, washington 98002-5518 t = 206 + 380 + 0732, e-mail = alhpe_sliderule@q.com RECEIVED BY CKC May 16, 2022 i jv-1 L�s jtT ,o �In,�ytnfi->rtuw� CooC� 1-r17® �o ozv psi �'�l TS2rtZx3�� \l = � �2•ri � �� 6-C9�-livt3 Fclvl�-co 4 Foclk;sl F(-� e 22�i 2 > 7,6v t-� s t� ��-G�• �� �ciST' c arvc_ -4it s 2S77 Zi lye) I- &-r- i(--/,V� 4� e4 4. v— d* k= Y-;, ,v► Z- O D.�3 4b 1,4 Z' RECEIVED BY CKC May 16, 2022 • O JLJ i f ` 1 � , CD it LU Pe t i 2 04 7�7> Stamp signifies shop a h�� Ui drawing complies with the intent of the . , structural calculations. • e T — W At O O ML RECEDED BY CKC May 16, 2022 E � 3 7/8" DOESN'T HAVE ENOUGH_ -;- TOLERANCE. PLEASE REV.ISETQ 31/2",, TYPICAI, - SMS,. 1 } I 3 — -- I- I- ; st?mp; s- sh p s !! ► dr wing compI" h P. tN mt' 'f the S - -- i structural caleulati OV WAS OEL22 170, 14 %Oo --- - - - �t 0 R } , . 1 1 ! ! 4 r - Stamp signifies shop 4 drawing complies with i 3 , ti}e-tnte�}t :of -the ' structural •calcu lati o'ns. 3 Cif ST,IV- MAL <� M22 i3y n 6 p INC, l WtOfI Y Tit; P (Oil;Ct., �p�d . �pN1 LTI►�s; q�J :. 0 19 r r f i r ESR-1917 I Most Widely Accepted and Trusted Page 7 of 11 TABLE _,_,_nFRlnN IMMMMATInN RAMMMI CTCCI I[12_77 DESIGN INFORMATION Symbol Units Nominal anchor diameter 3/8 1/2 5/8 3/4 Anchor O.D. de(do) in. 0.375 0.5 0.625 0.75 mm 9.5 12.7 15.9 19.1 Effective min. embedment' her In. 2 2 3-1/4 3-1/8 4 3-3/4 4-3/4 (mm) (51) (51) (83) (79) (102) (95) (121) Min. member thickness2 hmm- in. 4 5 4 6 6 8 5 6 8 8 (mm) (102) (127 (102 (152) (152 (203) 127) (13) (152) (203) 203 Critical edge distance ceC in. 4-3/8 4 5-1/2 4-1/2 7-1/2 6 6-1/2 :(2±22)171) /4 10 8 9 mm (111) 102) (140) 114) (191) (152) (165) (254) (203) (229 cm'" In. 2-1/2 2-3/4 2-3/8 3-5/8 3-1/4 4-3/4 4-1/8 Min, edge distance mm 64) 70) 1 (60) (92) (83) (121) (105) for s Z in. 5 5-3/4 5-3/4 6-1/8 5-7/8 10,112 8-7/8 (mm) (127) (146) (146) (156) (149) 267) 225) sm'" in. 2-1/2 2-3/4 2-3/8 3-1/2 3 5 4 Min. anchor spacing mm 64 70 60 89 76 127 102) for c Z In. 3-5/8 4-1/8 3-1/2 4-3/4 4-1/4 9-1/2 7-3/4 (mm (92) (105 89 (121) (108 • (241) (197) Min. hole depth in concrete ho in. 2-5/8 2-5/8 4 3-3/4 4-3/4 4-1/2 5-3/4 (mm) 67 67 102 98 421 117 146 Min. specified yield strength fy Iblin z 100,000 84,800 84,800 841800 N/mm 690 585 585 585 Min. specified ult. strength fie lb/in 115,000 106,000 106,000 106,000 N/mm 2 793 731 731 731 Effective tensile stress area AS,,N In 2 0.052 0.101 0.162 0.237 mm 33.6 65.0 104.6 152.8 Steel strength in tension Nsa lb 6,500 10,705 17,170 25,120 kN 28.9 47.6 76.4 111.8 Steel strength in shear VSe lb 3,595 5,495 8,090 13,675 kN 16.0 24.4 36.0 60.8 Steel strength in shear, seismica VeQ lb 2,255 5,495 7,600 11,745 kN 10.0 24.4 33.8 52.2 Steel strength in shear, Vse,x lb 2,13012 3,000 4,945 4,60012 6,04012 concrete on metal deck (kN) (9.5) (13.3) (22) (20.5) (26.9) NP NP Pullout strength uncracked NP,. lb 2,515 NA 5,515 9,145 8,280 10,680 concretes (kN) (11.2) (24.5) NA (40.7 (36.8) (47.5) Pullout strength cracked concretes N,- Ib 2,270 NA 4,915 NA NA NA NA kN 10.1 219 Pullout strength concrete on metal deck6 Nc.aecn,cr lb 1,460 1,460 2,620 2,000 4,645 NP NP (kN) 6.5 6.5 11.7 8.9 20.7 Anchor category' 1 Effectiveness factor k_, uncracked concrete 24 Effectiveness factor k, cracked concrete' 17 'Pc, N= k.,,A r 9 1.0 Coefficient for pryout strength, kip 1.0 2.0 Strength reduction factor ¢for tension, steel failure modes10 0.75 Strength reduction factor ¢for shear, steel failure modes10 0.65 Strength reduction 0 factor for tension, concrete failure modes or pullout, Condition B11 0.65 Strength reduction ¢ factor for shear, concrete failure modes, Condition B11 0.70 •r For Si; i inch = L5.4 mm, 1 lot = 4.45 N, 1 psi = 0.006896 MPa For pound -inch units: 1 mm = 0.03937 inches. 'See Fig. 2. 2 For sand -lightweight concrete over metal deck, see Figure 5. 3 See Section 4.1.8 of this report. °See Section 4.1.5. NP (not permitted) denotes that the condition is not supported by this report. sFor all design cases W p=1.0. NA (not applicable) denotes that this value does not control for design. See Section 4.1.4 of this report. See Section 4.1.4 of this report. NP (not permitted) denotes that the condition is not supported by this report. Values are for cracked concrete. Values are applicable to both static and seismic load combinations. 'See ACI 318 Section DAA 8See ACI 318Section D.5.2.2. e For all design cases Wc,N =1.0. The appropriate effectiveness factor for cracked concrete (kr) or uncracked concrete (k air) must be used. "The KB-TZ is a ductile steel element as defined by ACI 318 D.1. "For use with the load combinations of ACI 318 Section 9.2. Condition B applies where supplementary reinforcement in conformance with ACI 318 Section D.4.4 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used. t2 For seismic applications according to Section 4.1.8 of this report multiply the value of V.,d_k for the 318-inch-diameter by 0.63 and the 5/8-inch-diameter by 0.94. RECEIVED BY CKC May 16, 2022