REV6 APPROVED BLD REV 6 BLD2018-1622 Hold downs - STRUC PLANSCary Kopczynski & Company 10500 NE 8th Street, Suite 800 Bellevue, WA 98004 ffm P: (425) 455-2144 STRUCTURAL ENGINEERS www.ckcps.com LETTER OF TRANSMITTAL DATE: 03-11-21 ATTN: Lucas Branham Studio Meng Strazzara 2001 Western Ave., Suite 200 Seattle, WA 98121 RECEIVED May 11 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PHONE: (206) 587-3797 RE: Edmonds HWY 99 Apartments VIA: Email COPIES DESCRIPTION 1 CKC Response - Submittal 06 5600-02 - Holdowns - Calcs & Shop Drawings REMARKS: SIGNED:*4-ee r Joel Kipple, PE, SE Project Manager Associate COPY: Titus Uomoto Brad Carpenter Ben Lek BLD2021-0652 JOB NO. 1853 ❑ FOR APPROVAL FOR REVIEW & COMMENT ■ AS REQUESTED ■ FOR YOUR USE GRE GRE GRE LEADERS IN BUILDABLE DESIGN SEATTLE I SAN FRANCISCO I LOS ANGELES I CHICAGO RECEIVED BY CKC Feb 26, 2021 c� Sent To: Lucas Branham RECEIVED May 11 2021 CITY OF EDMONDS SUBMITTAL DEVELOPMENTDEPARTM NRVICES Firm: Studio Meng Strazzara Address: 2001 Western Ave, Suite200 Seattle, WA 98121 Return To: Ben Lek Firm: GRE Construction LLC Address: 2801 Alaskan Way, Suite310 Seattle, WA 98121 Project: GRE Edmonds99 Spec Section #: 06 5600 Submittal #: 06 5600-02 Submittal Name: Holdowns- Calcs& Shop Drawing; Revision #: 0 Sent Date: 02/26/2021 Required Date: 03/12/2021 Description Submittal Type Spec Section Notes Rough Carpentry - Holdowns Calculations 065600 Rough Carpentry - Holdowns Shop Drawing 065600 Remarks/Comments/Stamps: Project (G- 0GRE Edmonds 99 Reviewed ❑ Reviewed as Noted ❑ Revise & Resubmit ❑ Rejected Reviewed by Ben Lek Date 2/26/2021 Submittal # 06 5600-02 Spec # This submittal/shop drawing has been reviewed by GRE Construction LLC for general conformance with design concept only and does not relieve this Subcontractor or Supplier of the responsibility for compliance with the Contract Documents, applicable codes, and laws, all of which have priority over this submittal. Subcontractor/Supplier is responsible for all dimensions and fabrication to be confirmed at the jobsite. WOOD G0N5TRUGTI0N: Al IBG GHAFTER 1105 AND 2303 REQUIRED 5PEGIAL IN5PEG7ION5 AND 7E575 OF WOOD FRAMING VERIFICATION AND INSPECTION PERIOD REFERENCES SHEAR WALL NAILING P5 IBG 1105.11.1 NAILING, BOLTING AND ANCHORAGE OF COMPONENTS THAT ARE PART OF DRAG STRUT BRACES AND HOLD DOAN5 THAT ARE PART OF THE LATERAL-FORCE-RE5I5TIN6 SYSTEM. P5 IBO 1105.12.2 , A, A STRAPS, ROOF CLIP5, HANGERS AND MISC CONNECTORS P5 I5C 1104.2.5 Submittal Review for Elements Designed by Others 0 NO EXCEPTION TAKEN ❑ REVISE AND RESUBMIT ❑ SUBMIT SPECIFIED ITEMS ❑ MAKE CORRECTIONS NOTED ❑ REJECTED ❑ NOT REVIEWED 99 STRUCTURAL ENGINEERS ANY ACTION NOTED ABOVE IS SUBJECT TO THE REQUIREMENTS OF THE PROJECT PLANS AND SPECIFICATIONS. CKC IS ENTITLED TO RELY ON THE COMPLETENESS AND ACCURACY OF ALL INFORMATION IN THIS SUBMITTAL. OUR REVIEW WAS ONLY TO CHECK FOR GENERAL COMPATIBILITY WITH THE DESIGN INDICATED IN DOCUMENTS PREPARED BY CKC. IT WAS NOT PERFORMED FOR THE PURPOSE OF DETERMINING DESIGN ADEQUACY, SUITABILITY, OR COMPLETENESS FOR THE SUBMITTED ELEMENTS, OR FOR CHECKING DESIGN CALCULATIONS OR DESIGN ASSUMPTIONS. CKC'S REVIEW DOES NOT RELIEVE OTHER PARTIES FROM RESPONSIBILITY FOR ADEQUACY, ACCURACY, AND COMPLETENESS OF DESIGN OF THE SUBMITTED ELEMENTS, INCLUDING ATTACHMENTS; CORRECTNESS OF DIMENSIONS AND QUANTITIES; VERIFICATION OF PHYSICAL INTER -RELATION OF ELEMENTS; AND CONSTRUCTION PROCEDURES, TECHNIQUES AND SEQUENCES. BY DP/JK CKC Notes for Entire Submittal: Stamp applies to all sheets of this submittal. PLAN REVIEW ACCEPTANCE FOR COMPLIANCE WITH THE APPLICABLE CONSTRUCTION CODES IDENTIFIED BELOW. ❑ BUILDING ® STRUCTURAL ❑ MECHANICAL ❑ PLUMBING ❑ ELECTRICAL ❑ ENERGY ❑ ACCESSIBILITY ❑ FIRE PLAN REVIEW ACCEPTANCE OF DOCUMENTS DOES NOT AUTHORIZE CONSTRUCTION TO PROCEED IN VIOLATION OF ANY FEDERAL, STATE, OR LOCAL REGULATIONS. 06 5600-02 BY: "� 71— ,� ��- DATE:6/1/2021 WEST COAS CODE CONSULTANTS, INC. DATE 3/11/2021 - Calcs & Shop Drawings GENERAL NOTES 1. THE SLACKJACK TM DEVICE COMPONENTS INCLUDE: A. SJA INNER AND OUTER SLEEVE CYLINDERS B. PRE -COMPRESSED COMPRESSION SPRING C. NUT: ALL NUTS TO CONFORM TO ASTM A563 GRADE "A" FOR 60 ksi AND GRADE "C" FOR 120 ksi TENSILE STRENGTH THREADED RODS. D. SWIVEL WASHER 2. ALL THREADED RODS SHALL CONFORM TO THE FOLLOWING SHOP DRAWING MARKS: 1. Rx = ASTM A36 OR A307, fu = 60 ksi. 2. RxM = ASTM F1554 GRADE 55, fu = 75 ksi. 3. RxHS = ASTM A449 (fu = 120 ksi UP 1". fu = 105 ksi 1-1/8" THRU 2-1/2") or ASTM A193137 (fu = 125 ksi). NOTES: a. x = ROD DIAMETER IN EIGHTS OF AN INCH. (ie. R7M = 7/8" ASTM F1554 GRADE 55) b. "M" ROD ARE ZINC PLATED FINISH. 3. STANDARD AND HIGH STRENGTH (HS) RODS ARE BLACK ;STEEL, HS WILL BE MARKED WITH AN ORANGE TAPE. 4. ALL BEARING PLATES ARE FABRICATED FROM ASTM A36 STEEL. 5. ALL STEEL BEARING PLATES SHALL HAVE FULL BEARING CONTACT AREA ON WOOD MEMBERS. 6. COUPLING NUT CONNECTION: CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT AT CONNECTIONS WITH THE SAME SIZE ROD THAT EACH ROD IS THREADED HALF WAY INTO COUPLER FROM EACH SIDE. HIGH STRENGTH (HS) COUPLERS SHALL BE USED WITH HIGH STRENGTH (HS) RODS UNLESS NOTED OTHERWISE. STANDARD STRENGTH COUPLERS ARE ZINC PLATED. HIGH STRENGTH (HS) ARE NOT PLATED. WHERE REDUCING COUPLERS ARE USED, COUPLER SHALL 13E FULLY SEATED ON THE LARGER DIAMETER ROD BEFORE ENGAGING THE SMALLER DIAMETER ROD. SIGHT HOLES ARE PROVIDED ON STRAIGHT COUPLERS ONLY, SIGHT HOLES ARE NOT REQUIRED ON REDUCING COUPLERS. 7. COLORS REFERENCED ON THIS DRAWING ARE PROVIDED FOR CONVENIENCE TO THE INSTALLER AND FOR INSPECTION PURPOSES. 8. SILICONE OR CAULKING SHALL NOT BE PLACED INTO THE SLACKJACK DEVICE OR ANY DRILLED HOLE FOR RODS AT ANY TIME. CONTRACTOR SHALL USE FIRE RATED ROCKWOOL OR NON -HARDENING FIRESTOP. (PROVIDED BY OTHERS). 9. ANCHOR BOLTS ARE SPECIFIED BY EARTHBOUND TO CONFORM TO THE LOADS REQUIRED ON THE STRUCTURAL PLANS. CONTRACTOR SHALL BE RESPONSABLE TO VERIFY AND COORDINATE SCHEDULED ANCHOR BOLTS WITH THESE ASSEMBLIES. 10. HOLDOWN RUN ELEVATION VIEWS ARE DIAGRAMS AND MAY NOT DEPICT THE CORRECT NUMBER OF COLLECTOR STUDS REQUIRED. REFER TO COLLECTOR STUD PLAN DIAGRAMS FOR REQUIRED AMOUNT OF ADDITIONAL STUDS DEPENDING ON SHEAR WALL FRAMING TYPE. ADDITIONAL COMPRESSION STUDS OR POSTS MAY BE REQUIRED BY THE STRUCTURAL PLANS FOR DEAD AND LIVE LOADS. 11. THIS DRAWING WILL BE REVIEWED BY THE ENGINEER OF RE -CORD. UPON APPROVAL, U.N.O. THIS DRAWING REPLACES THE HOLDOWN SYSTEM PER THE STRUCTURAL PLANS. 12. ENGINEER OF RECORD SHALL VERIFY COMPLETE LOAD TRANSFER TO FOUNDATION LEVEL INCLUDING ALL CODE REQUIRED LOAD FACTORS. 13. WOOD FLOOR LEVELS SHOWN ARE RELATIVE TO THE CONCRETE FOUNDATION AND MAY NOT REFLECT THOSE SHOWN IN THE PLANS. 14. CONTRACTOR MAY SUBSTITUTE POSTS WITH 2x MEMBERS OR VICE VERSA ONLY IF TOTAL BEARING PLATE AREA ON BOTTOM PLATE IS EQUAL. 15. REFER TO THE COLLECTOR STUD SCHEDULE FOR WOOD STUD AND FLOOR PLATE MATERIALS USED IN LOAD CALCULATION ASSUMPTIONS. THE MATERIALS SHALL MATCH STRUCTURAL DRAWING REQUIREMENTS UNLESS NOTED OTHERWISE. 16. FULL HEIGHT COLLECTOR STUD REQUIREMENTS (NOT AT BRIDGE LEVEL - SEE 17A): A. FULL HEIGHT BUNDLED 2x, 3x COLLECTOR/COMPRESSION STUDS, THE OUTERMOST STUD FROM EACH SIDE OF THE THREADED ROD SHALL RECEIVE EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. EDGE NAILING MAY BE STAGGERED/DISPERSED ON (2) MEMBERS MAX. ANY REMAINING INTERIOR STUDS SHALL RECEIVE FIELD NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. B. FULL HEIGHT 4x COLLECTOR/COMPRESSION AT OUTERMOST POST FROM EACH SIDE OF THE THREADED ROD SHALL RECEIVE ONE (1) ROW OF EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. ANY REMAINING 2x, 3x, 4x INTERIOR MEMBERS SHALL RECEIVE FIELD NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. C. FULL HEIGHT 6x AND LARGER COLLECTOR/COMPRESSION AT OUTERMOST POST FROM EACH SIDE OF THE THREADED ROD SHALL RECEIVE TWO (2) ROWS OF EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. ANY REMAINING INTERIOR POSTS CAN BE FIELD NAILED PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. D. WINDOW AND DOOR TRIMMERS MAY BE USED AS HOLDOWN COLLECTOR STUDS IF THE FOLLOWING CONDITIONS ARE MET: - A CONTINUOUS VERTICAL LOAD PATH SHALL EXIST FROM WALL TOP PLTS. TO WALL BOTTOM PLTS. - ALL WOOD MEMBERS IN THE CONTINUOUS VERTICAL LOAD PATH SHALL BE NAILED ACCORDING TO THE EARTHBOUND SYSTEM REQUIREMENTS. - THE SHEAR PANEL MUST EXTEND TO INCLUDE THE TRIMMERS USED. E. COMPRESSION STUDS/POSTS SHALL BE INSTALLED SYMMETRICALLY ABOUT ROD. WHERE QUANTITY OF STUDS IS GREATER THAN THE SPACE BETWEEN ROD OR BEARING PLATE AND THE END OF SHEAR WALL THE ADDITIONAL REQUIRED STUDS SHALL BE ADDED TO THE OPPOSITE SIDE OF ROD (ASYMMETRICALLY). F. STITCH NAILING OF BUNDLED OR BUILT UP STUD PACKS SHALL CONFORM TO IBC TABLE 2304.10.1. 17. COMPRESSION BRIDGE REQUIREMENTS: A. ALL FULL HEIGHT 2x AND 3x MEMBERS ON EITHER END OF THE BRIDGE SHALL RECEIVE EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. B. ALL FULL HEIGHT 4x COLLECTOR/COMPRESSION POSTS DN EITHER SIDE OF THE BRIDGE SHALL RECEIVE ONE (1) ROW OF EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. C. ALL FULL HEIGHT 6x AND LARGER COLLECTOR /COMPRESSI ON POSTS ON EITHER SIDE OF THE BRIDGE SHALL RECEIVE TWO (2) ROWS OF EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. D. ALL BRIDGE TRIMMERS SHALL BE 2x MEMBERS ONLY (U.N.O.) AND SHALL BE INSTALLED SYMMETRICALLY AS SHOWN (U.N.O.). E. ALL BRIDGE TRIMMERS SHALL RECEIVE EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS (U.N.O.). F. THE BRIDGE TRIMMERS ADJACENT TO THE FULL HEIGHT STUDS (ONE EACH SIDE) SHALL RECEIVE FACE (STITCH) NAILING TWO (2) ROWS AT 4" O.C. TRIMMERS IN ADDITION TO ONE EACH SIDE SHALL BE STITCH NAILED AT 12" O.C. AS REQUIRED BY IBC TABLE 2304.10.1. FACE NAILS MAY BE NAILED FROM THE OPPOSITE DIRECTION THAN THAT SHOWN IN THE DETAIL. G. FACE NAILS SHALL BE 10d MINIMUM. USE 16d NAILS MINIMUM WHEN NAILING THROUGH 3x STUDS INTO 2x BRIDGE TRIMMERS. H. IF MULTIPLE BRIDGE TRIMMERS ON EACH SIDE ARE REQUIRED, DO NOT INSTALL THE TRIMMERS IN ADDITION TO ONE EACH SIDE UNTIL THE FACE NAILING HAS BEEN INSPECTED AND APPROVED. I. BRIDGE BLOCK SHALL BE 4x6 DF IN 4x WALLS, 6x6 DF IN 6x WALLS (U.N.O.). BRIDGE BLOCK SHALL ALWAYS BE 5-1/2" TALL MINIMUM. J. BRIDGE BLOCK SHALL BE DOUGLAS FIR CONSTRUCTION GRADE WITH MINIMUM 800 PSI ALLOWABLE BENDING STRESS. TIMBERSTRAND LSL BEAM MATERIAL OF EQUAL OR GREATER DIMENSION IS AN ACCEPTABLE ALTERNATE (U.N.O.). K. BRIDGE HEIGHTS SHOWN ARE THE MINIMUM HEIGHT FROM SUBFLOOR TO BOTTOM OF BRIDGE MEMBER. L. ONLY COMMON NAILS SHALL BE USED. 18. DRILLED OR BORED HOLES: DRILLED HOLES THROUGH VERTICAL COMPRESSION MEMBERS SHALL NOT EXCEED 25% OF THE STUD OR POST WIDTH, FOR EXAMPLE: 7/8" DIA. HOLE IS MAXIMUM ALLOWED IN 3 1/2" WIDE STUD OR POST UNLESS APPROVED BY EOR. THE BORED HOLE SHALL BE AT LEAST 5/8" AWAY FROM EDGE OF STUD. 19. CUTTING AND NOTCHING: WOOD VERTICAL COMPRESSION MEMBERS ARE PERMITTED TO BE CUT OR NOTCHED TO A DEPTH NOT EXCEEDING 25% OF IT'S WIDTH PER 2308.9.10 PER IBC 2015. 20. STUD/POST/TRIMMER NOTCHING AT CONFLICTING BEARING PLATES INTERFERENCE. A. THE MEMBER SHALL BE NOTCHED TO THE EXACT THICKNESS AND AREA OF THE STEEL PLATE TO MAINTAIN THE FULL BEARING AREA OF THE NOTCHED COMPRESSION MEMBER. B. IF THE REQUIREMENTS OF ITEM "A" ABOVE ARE NOT MET, THEN ADDITIONAL COMPRESSION MEMBERS SHALL BE ADDED TO ACHIEVE THE REQUIRED TOTAL BEARING AREA. ADDITIONAL COMPRESSION MEMBERS SHALL RECEIVE SHEAR PANEL NAILING PER THE REQUIREMENTS OF THE EARTHBOUND SHOP DRAWINGS. C. STEEL SHIMS OR FULL WIDTH PLATE MAY BE USED IN LIEU OF NOTCHING. 21. MINIMUM REQUIREMENTS FOR BLOCKING IN THE JOIST SPACE AT HOLDOWN LOCATIONS ARE: A. BLOCKING SHALL SPAN THE FULL WIDTH OF THE SHEAR WALL TOP PLATE OF THE FLOOR LEVEL BELOW THE JOIST SPACE. B. BLOCKING SHALL EQUAL THE OUTERMOST DIMENSIONS OF THE "FOOTPRINT" OF THE TOTAL HOLDOWN WOOD COMPRESSION MEMBERS OF THE FLOOR LEVELS BELOW AND ABOVE THE JOIST SPACE. C. THE SPACE BETWEEN BLOCKING WHERE THE ROD IS LOCATED SHALL NOT EXCEED 3". D. COMPRESSION CAPACITIES OF BLOCKING MATERIALS SHALL BE EQUAL TO OR GREATER THAN THE RELATED JOISTS. THE VERTICAL DIMENSIONS SHALL BE EQUAL. SEE NOTE "E" FOR EXCEPTION. E. VERTICAL GRAIN BLOCKING SHALL BE TRIMMED TO ACCOUNT FOR POSSIBLE SHRINKAGE OF THE JOISTS. CONTACT JOIST MANUFACTURER FOR SHRINKAGE INFORMATION. F. FLOOR JOISTS SHALL NOT BE REMOVED TO ALLOW FOR THE INSTALLATION OF BLOCKING. BLOCKING IS IN ADDITION TO THE EXISTING JOISTS. G. WEB STIFFENERS SHALL BE ADDED TO ENGINEERED LUMBER "I" JOISTS AND "I" JOIST MATERIAL USED AS BLOCKING. SEE NOTE "B" ABOVE. ABBREVIATIONS AB ANCHOR BOLT PER ROD COMPONENT SCHEDULE BLKG BLOCKING C COUPLER FND FOUNDATION G HOT DIPPED GALVANIZED ROD OR GALV. TAPPED COMPONENT GG COUPLER GALV. TAPPED ON BOTH ENDS GS COUPLER GALV. TAPPED ON SMALL END ONLY CB CORROSION BARRIER HS HIGH STRENGTH SJA 4XY SLACKJACKTM COMPONENT (X) = SLACKJACK DEVICE SERIES TRAVEL 1=1 INCH (RED), 2=2 INCHES (GREEN) (Y) = ROD SIZE JST JOIST MIN. MINIMUM O.C. ON CENTER P PLATE PG PERPENDICULAR TO GRAIN R ROD UNO UNLESS NOTED OTHERWISE SHOP DRAWING DISCLAIMER THESE SHOP DRAWINGS ILLUSTRATE THE DETAILS OF THE EARTHBOUND SEISMIC HOLDOWN SYSTEM. THEY WERE PREPARED IN CONFORMANCE WITH THE STRUCTURAL DESIGN PROVIDED TO EARTHBOUND CORPORATION ("EB CORP.") BY THE PROJECT OWNER OR ITS REPRESENTATIVE. EB CORP. TOOK NO PART IN THE PREPARATION OR REVIEW OF SAID STRUCTURAL DESIGN AND EB CORP DISCLAIMS ANY LIABILITY FOR IT. THE STAMP OR SEAL OF AN EB CORPORATION EMPLOYEE OR AGENT ON THESE SHOP DRAWINGS PERTAIN ONLY TO THE TRANSFER OF THE FORCES REQUIRED BY THE ENGINEER OF RECORD ON THE STRUCTURAL DRAWINGS AND NOT TO THE REVIEW AND ADEQUACY OF THE STRUCTURAL DESIGN. NO WARRANTY, EXPRESSED OR IMPLIED, AS TO THE ADEQUACY OF THE STRUCTURAL DESIGN IS MADE BY ANY SUCH STAMP OR SEAL. COLLECTOR STUD DIAGRAM KEY WALL TYPE (TYP) \cn CnLLI oQ CnJ Cn a - LL Q WOOD SPECIES FRAMING LVL AND HEIGHT -APPROX. ROD LOCATION (TYP) - ANCHOR BOLT LAYOUT DIMENSION (TYP) STUD OR POST (TYP) SHEAR WALL STUD/POST (QTY) & DESCRIPTION (TYP) END MEMBERS (TYP) COLLECTOR STUDS REQUIRED 4x WALLS: 0 1 9" _j 4x6 4x8 J 6x WALLS- 5 2x's TOTAL 1. * (ASTERISK) INDICATES 1/2 HEIGHT TRIMMER (UNLESS NOTED OTHERWISE) FOR COMPRESSION BRIDGE. 2. COLLECTOR STUDS SHOWN ARE THE MINIMUM REQUIREMENT TO EQUAL THE UPLIFT TENSION FORCES CALLED OUT BY THE STRUCTURAL DWGS. ADDITIONAL COMPRESSION STUDS OR POSTS MAY BE REQUIRED BY STRUCTURAL ENGINEER OF RECORD. APPLIES TO ALL HOLDOWN RUNS. COMPONENT SELECTION SCHEDULES EARTHBOUND THREADED ROD CAPACITIES IBC 2015 ROD SIZE ROD SIZE (INCHES) ALLOWABLE TENSION LOAD ROD REMARKS SLACKJACK SIZE IBC 2015 R4 1/2" DIA. 4,470 LBS ASTM A 307 (UNC) MJ100, MJ200 R5 5/8" DIA. 7,120 LBS ASTM A 307 (UNC) SJA 215, 225, 415, 425 R6 3/4" DIA. 10,540 LBS ASTM A 307 (UNC) SJA 216, 226, 416, 426, HJA 716, 726 R7 7/8" DIA. 14,540 LBS ASTM A 307 (UNC) SJA 217, 227, 417, 427, HJA 717, 727 R8 1" DIA. 19,080 LBS ASTM A 307 (UNC) SJA 218, 228, 418, 428, HJA 718, 728 R9 1 1/8" DIA. 24,040 LBS ASTM A 307 (UNC) SJA 219, 229, 419, 429, HJA 719, 729 R10 1 1/4" DIA. 30,530 LBS ASTM A 307 (UNC) SJA 4110, 4210, HJA 7110, 7210, HJS 4110, 4210, 7110, 7210 R12 1 1/2" DIA. 44,270 LBS ASTM A 307 (UNC) SJST 4112, 4212, HJA 7112, 7212, HJS 4112, 4212, 7112, 7212 R14 1 3/4" DIA. 59,830 LBS ASTM A 307 (UNC) ----- R6M 3/4" DIA. 13,170 LBS ASTM F1554 GR55 (UNC) SJA 216, 226, 416, 426, HJA 716, 726 R7M 7/8" DIA. 18,180 LBS ASTM F1554 GR55 (UNC) SJA 217, 227, 417, 427, HJA 717, 727 R8M 1" DIA. 23,850 LBS ASTM F1554 GR55 (UNC) SJA 218, 228, 418, 428, HJA 718, 728 R9M 1 1/8" DIA. 30,050 LBS ASTM F1554 GR55 (UNC) SJA 219, 229, 419, 429, HJA 719, 729 R10M 1 1/4" DIA. 38,160 LBS ASTM F1554 GR55 (UNC) SJA 4110, 4210, HJA 7110, 7210, HJS 4110, 4210, 7110, 7210 R12M 1 1/2" DIA. 55,330 LBS ASTM F1554 GR55 (UNC) SJST 4112, 4212, HJA 7112, 7212, HJS 4112, 4212, 7112, 7212 R14M 1 3/4" DIA. 74,790 LBS ASTM F1554 GR55 (UNC) ----- R61HS 3/4" DIA. 21,950 LBS ASTM A193 B7 (UNC) SJA 216, 226, 416, 426, HJA 716, 726 R7HS 7/8" DIA. 30,300 LBS ASTM Al93 B7 (UNC) SJA 217, 227, 417, 427, HJA 717, 727 R8HS 1" DIA. 39,750 LBS ASTM Al93 B7 (UNC) SJA 218, 228, 418, 428, HJA 718, 728 R9HS 1 1/8" DIA. 50,090 LBS ASTM Al93 B7 (UNC) SJA 219, 229, 419, 429, HJA 719, 729 R10HS 1 1/4" DIA. 63,600 LBS ASTM Al93 B7 (UNC) SJA 4110, 4210, HJA 7110, 7210, HJS 4110, 4210, 7110 ,7210 R12HS 1 1/2" DIA. 92,220 LBS ASTM Al93 B7 (UNC) SJST 4112, 4212, HJA 7112, 7212, HJS 4112, 4212, 7112, 7212 R14HS 1 3/4" DIA. 124,650 LBS ASTM Al93 87 (UNC) ----- COLLECTOR STUD CAPACITY SCHEDULES COLLECTOR STUD CAPACITIES FOR DOUG FIR STUDS ON DOUG FIR PLATES TOTAL 9'-O" CAPACITY ** 4'-6"/6'-0" CAPACITY STUDS REQUIRED 2x4 STUDS 2x6 STUDS 4x4 POSTS 4x6 POSTS 4x8 POSTS 6x6 POSTS BRIDGE TRIMMERS ONLY QTY. PLAN VIEW NO. OF BRIDGE TRIMMERS 2x4s 2x6s SINGLE CAPACITY: 2,739# 5,156# 6,391# 10,015# 13,161# 18,906# 3,281# 5,156# 2 5,478# 10,313# 12,781 # 20,030# 26,322# 37,813# 2* 6,563# 10,313# 3 8,217# 15,469# 19,172# 30,045# 39,484# 56,719# 4 10,955# 20,625# 25,563# 40,059# 52,645# 75,625# 4* 13,125# 20,625# 5 ® 13,694# 25,781 # 31,953# 50,074# 65,806# 94,531 # 6 16,433# 30,938# 38,344# 60,089# 78,967# 113,438# 6* 19,688# 30,938# 7 19,172# 36,094# 44,735# 70,104# 92,128# 132,344# 8 21,911# 41,250# 51,125# 80,119# 105,289# 151,250# 8* 26,250# 41,250# 9 24,650# 46,406# 57,516# 90,134# 118,451# 170,156# 10 27,388# 51,563# 63,906# 100,149# 131,612# 189,063# NOTES: 1) STUDS SHOWN ARE THE MINIMUM COMPRESSION MEMBERS REQUIRED FOR THE EARTHBOUND SYSTEM. 2) DOUG FIR CALCULATION NOTES: (BASED ON 2015 NDS) 2x4s, 2x6s, 3x4s, 4x4s, AND LARGER (NO. 2 GRADE): F'c PARALLEL = 135J PSI 6x6s AND LARGER (NO. 1 GRADE) F'C PARALLEL = 1000 PSI 3) * DENOTES NO. OF BRIDGE TRIMMERS UNDER COMPRESSION BRIDGE. 4) ** DENOTES THAT FINAL POST HEIGHT SUBTRACTS 4 1/2" FOR 2x TOP PLATES AND 2x BOTTOM PLATE. EARTHBOUND BEARING PLATE CAPACITIES DF SJA ROD SIZE CODES PLATE SIZE DIFFERENTIAL LOAD COLOR CODE PLATE DIMENSIONS INCHES PART NO. ROD DIAMETER ROD SIZE WASHER COLOR WIDTH LENGTH THICK. P6 6,650 LBS GREEN 3" 3.5" 1/4" MJ100 or MJ200 1/2" R4 PURPLE PS 8,470 LBS BLACK 3-1/4" 4.25" 1/4" SJA 2x5 or 4x5 5/8" R5 BLACK P10 10,320 LBS BLUE 3-1/4" 5" 3/8" SJA 2x6 or 4x6, HJA 7x6 3/4" R6 or R6HS GRAY p12 12,230 LBS GRAY 3-1/4" 6" 5/8" SJA 2x7 or 4x7, HJA 7x7 7/8" R7 or R7HS BLUE P14 13,660 LBS RED 3-1/4" 7" 3/4" SJA 2x8 or 4x8, HJA 7x8 1" R8 or R8HS YELLOW Pie 18,840 LBS YELLOW 3-1/2" 9" 1" SJA 2x9 or 4x9, HJA 7x9 1 1/8" R9 or R9HS WHITE P20 21,020 LBS BROWN 3-1/2" loll 1" SJA 4x10, HJA 7x10, HJS 400, HJS 7x10 1 1/4" R10 or R10HS GREEN P22 23,210 LBS WHITE 3-1/2" 11" 1 1/4" SJST 4x12, HJA 7x12, HJS 4xl2, HJS 7x12 1 1/2" 1 R12 or R12HS RED P24 24,310 LBS GOLD 3-1/2" 11.5" 1 1/4" "x" = SLACKJACK TRAVEL IN "INCHES" P26 26,490 LBS ORANGE 3-1/2" 12.5" 1 1/2" NOTES: 1. TENSION LOAD WAS CALCULATED FROM THE FOLLOWING EQUATION: A. ASTM A 307 Threaded Rod Capacities are F'u = 60,000 pal. UNC thread pitch M Rods are based on ASTM F1554 GR55, F'u - 75 kaL HS Rods are based on ASTM A193 B7, F'u = 125 ksi B. The IBC 2015 column is calculated in accordance to Section 1905 and ASCE 7-10. 2. PLATE STEEL SHALL BE ASTM A36: F'u = 60,000 PSI. 3. SUBSTITUTIONS OF DESIGNATED BEARING PLATE SHALL NOT BE PERMITTED, OBTAIN WRITTEN APPROVAL FROM THE ENGINEER. 4. ALL BEARING PLATE CAPACIEITES ARE BASED ON 1-1/16" HOLE, UNLESS NOTED OTHERWISE TYPICAL SLACKJACK TM COLOR KEY PART NO. SJA 418 RED IYELLOWI **CAPTURE RING WASHER COLOR COLOR ** SECONDARY COLOR APPLIES TO HJS MODEL/SERIES OUTER CYLINDER ONLY. 5. SLACKJACK SELECTION NOTES: THE SIZES SHOWN ABOVE ARE FOR BOTH ONE AND TWO INCH TRAVEL ("SJA 4xy") (x = TRAVEL HEIGHT IN INCHES, y = ROD SIZE). TWO INCH TRAVEL SLACKJACKS ARE REQUIRED ON FOURTH WOOD FRAME LEVELS AND HIGHER. 6. THIS TABLE IS FOR REFERENCE OF FULL PRODUCT LINE, SOME ROD AND PLATE SIZES MAY NOT BE IN USE. THE ENGINEER OF RECORD SHALL REVIEW AND APPROVE CAPACITIES. rx Y Z X = DETAIL NUMBER Y = ELEVATION SHEET Z = DETAIL DRAWN ON EARTHBOUND DETAIL BUBBLE LEGEND DEVICE CAN BE ACTIVATED AS SOON AS IT IS INSTALLED AND HEX NUT TIGHTENED IN PLACE. PULL CL MINIJACK CAPTURE RING (SEE COLOR CODE) PULL CLIP SLACKJACK - IAPMO ER-0429 & LABC LISTED CAPACITIES COLOR CODE AND MODEL/SERIES TO PART NUMBER CROSS REFERENCE TOP NUT o SWIVEL WASHER (SEE COLOR CODE) O CAPTURE RING (SEE COLOR CODE) BEARING PLATE IAPMO ER-0429 /LABC MODEL/SERIES SLACKJACK PART NO. ON DWGS THREADED ROD DIAMETER COMPRESSION CAPACITY TRAVEL COMPENSATION AMOUNT CAPTURE RING COLOR SWIVEL WASHER COLOR IAPMO ER-0429 /LABC MODEL/SERIES SLACKJACK PART NO. ON DWGS THREADED ROD DIAMETER COMPRESSION CAPACITY TRAVEL COMPENSATION AMOUNT CAPTURE RING COLOR SWIVEL WASHER COLOR M 100 MJ 100 1/2" 5,000 LBS 1-INCH RED N/A M 200 MJ 200 1/2" 4,900 LBS 2-INCH ORANGE N/A A 210 SJA 215 5/8" 7,360 LBS 1-INCH BLUE BLACK A 220 SJA 225 5/8" 7,730 LBS 2-INCH YELLOW BLACK A 210 SJA 216 3/4" 7,360 LBS 1-INCH BLUE GRAY A 220 SJA 226 3/4" 7,730 LBS 2-INCH YELLOW GRAY A 210 SJA 217 7/8" 7,360 LBS 1-INCH BLUE BLUE A 220 SJA 227 7/8" 7,730 LBS 2-INCH YELLOW BLUE A 210 SJA 218 1" 7,360 LBS 1-INCH BLUE YELLOW A 220 SJA 228 1" 7,730 LBS 2-INCH YELLOW YELLOW A 210 SJA 219 1 1/8" 7,360 LBS 1-INCH BLUE WHITE A 220 SJA 229 1 1/8" 7,730 LBS 2-INCH YELLOW WHITE A 410 SJA 415 5/8" 14,000 LBS 1-INCH RED BLACK A 410 SJA 416 3/4" 14,000 LBS 1-INCH RED GRAY A 410 SJA 417 7/8" 14,000 LBS 1-INCH RED BLUE A 410 SJA 418 1" 14,000 LBS 1-INCH RED YELLOW A 410 SJA 419 1 1/8" 14,000 LBS 1-INCH RED WHITE A 410 SJA 4110 1 1 1/4" 14,000 LBS 1-INCH RED GREEN T 410 SJT 415 5/8" 9,000 LBS 1-INCH ORANGE BLACK T AA/1 I YIU f` - A4l� JUI YIU T /A" .J/-r n nnn I nC o,uuu Lu. 1-IINUrI URFIIVVL VR/1 `I T 410 SJT 417 7/8" 9,000 LBS 1-INCH ORANGE BLUE T 410 SJT 418 1" 9,000 LBS 1-INCH ORANGE YELLOW T 410 SJT 419 1 1/8" 9,000 LBS 1-INCH ORANGE WHITE T 410 SJT 4110 1 1/4" 9,000 LBS 1-INCH ORANGE GREEN HA 710 HJA 717 7/8" 15,650 LBS 1-INCH PURPLE BLUE HA 710 HJA 718 1" 15,650 LBS 1-INCH PURPLE YELLOW HA 710 HJA 719 1 1/8" 15,650 LBS 1-INCH PURPLE WHITE HA 710 HJA 7110 1 1/4" 15,650 LBS 1-INCH PURPLE GREEN HA 710 HJA 7112 1 1/2" 15,650 LBS 1-INCH PURPLE RED HA 720 HJA 727 7/8" 15,590 LBS 2-INCH GRAY BLUE HA 720 HJA 728 1" 15,590 LBS 2-INCH GRAY YELLOW HA 720 HJA 729 1 1/8" 15,590 LBS 2-INCH GRAY WHITE HA 720 1 HJA 7210 1 1/4" 1 15,590 LBS 2-INCH GRAY GREEN HA 720 HJA 7212 1 1/2" 15,590 LBS 2-INCH GRAY RED HS 410 HJS 419 1 1/8" 22,000 LBS 1-INCH BLACK** WHITE HS 410 HJS 4110 1 1/4" 22,000 LBS 1-INCH BLACK** GREEN HS 410 HJS 4112 1 1/2" 22,000 LBS 1-INCH BLACK** RED *SJST4210 1 1/4" 22,000 LBS 1 1/2-INCH BLACK GREEN *SJST4110 1 1/4" 22,000 LBS 1-INCH RED GREEN *SJST4112 1 1/2" 22,000 LBS 1-INCH RED RED * SLACKJACK TAKE UP DEVICE WITH LR = 0.003 IN. NOT SHOWN IN ER-0429. ** OUTSIDE CYLINDER COLOR AS FOLLOW: HJS41=BLUE, HJS42=YELLOW, HJS71=GREEN, HJS72=ORANGE A 420 SJA 425 5/8" 14,000 LBS 2-INCH GREEN BLACK A 420 SJA 426 3/4" 14,000 LBS 2-INCH GREEN GRAY A 420 SJA 427 7/8" 14,000 LBS 2-INCH GREEN BLUE A 420 SJA 428 1" 14,000 LBS 2-INCH GREEN YELLOW A 420 SJA 429 1 1/8" 14,000 LBS 2-INCH GREEN WHITE A 420 SJA 4210 1 1/4" 14,000 LBS 2-INCH GREEN GREEN A 610 SJA 616 3/4" 20,340 LBS 1-INCH TAN GRAY A -4- P1 Ulu [ IA C4-7 00P1 U I / 1 7 /011 / U nn ZAn I nc GV,JTV Luu I -1IN U," I MIN nl ULUL A 610 SJA 618 1" 20,340 LBS 1-INCH TAN YELLOW A 610 SJA 619 1 1/8" 20,340 LBS 1-INCH TAN WHITE A 610 SJA 6110 1 1/4" 20,340 LBS 1-INCH TAN GREEN A 620 SJA 627 7/8" 20,100 LBS 2-INCH WHITE BLUE A 620 SJA 628 1" 20,100 LBS 2-INCH WHITE YELLOW A 620 SJA 629 1 1/8" 20,100 LBS 2-INCH WHITE WHITE A 620 SJA 6210 1 1/4" 20,100 LBS 2-INCH WHITE GREEN HIS 420 HJS 429 1 1/8" 22,000 LBS 2-INCH BLACK** WHITE HIS 420 HJS 4210 1 1/4" 22,000 LBS 2-INCH BLACK** GREEN HS 420 HJS 4212 1 1/2" 22,000 LBS 2-INCH BLACK** RED HS 710 HJS 719 1 1/8" 39,190 LBS 1-INCH BLACK** WHITE HIS 710 HJS 7110 1 1/4" 39,190 LBS 1-INCH BLACK** GREEN HIS 710 HJS 7112 1 1/2" 39,190 LBS 1-INCH BLACK** RED HIS 720 HJS 729 1 1/8" 37,770 LBS 2-INCH BLACK** WHITE HS 720 HJS 7210 1 1/4" 37,770 LBS 2-INCH BLACK** GREEN HS 720 HJS 7212 1 1/2" 37,770 LBS 2-INCH BLACK** RED SLACKJACK COLOR CODE TABLE TRAVEL HEIGHT AND ROD SIZE COORDINATION SJA 428 MODEL: SLACKJACK ROD DIA IN EIGHTH INCH MODEL TYPE:77�T TRAVEL IN INCHES A=ALUM, S=STEEL SERIES TYPE (# RINGS) PANEL NAILING TM SLACKJACK NUT (TYP) DEVICE REFER TO EACH RUN TYPE FOR x TOTAL NUMBER I ,� OF TRIMMERS REQUIRED. ,l I J SHEAR WALL ROD-/ P-PLATES BOTTOM PLATE OR BRIDGE. FACE- TYP. P- PLATE ORIENTATION NAILING TYP & SAMPLE BRIDGE TRIMMER NAILING DETAIL. SCALE: NONE FULL HEIGHT STUD TYP. REQUIRED BRIDGE TRIMMER (TYP) ADDITIONAL TRIMMERS) TYP. EARTHBOUND RECOMMENDATION FOR ROD HOLE SCHEDULE THROUGH TOP BOTTOM PLATES AND BRIDGES ROD SIZE MIN HOLE SIZE MAX HOLE SIZE R4 1 /2" 0 1" b 1 -1 /8" o R5 5/8"o 1 "o 1-1 /8"o R6 3/4"0 1 "0 1-1 /8"o R7 7/8"o 1-1 /8"o 1-1 /4"0 R8 1 "� 1-1 /4"0 1-3/8, 0 R9 1-1/8', 0 1-3/8"0 1-1 /2"0 R10 1-1 4"0 1-1/2 0 1 -5 8"0 R12 1-1 /2"0 1-3/4"0 1-7/8"0 * HOLES SIZES INTENDED FOR 6" WALL TYPES ONLY. ENGINEER OF RECORD SHALL APPROVE THE USE OF THESE HOLE SIZES FOR 4" WALL TYPES. ALL SHEAR PANEL NAIL_ SPACING IS PER THE SHEAR WALL SCHEDULE EDGE NAIL FULL HEIGHT MEMBER AT EACH END OF BRIDGE BLOCK. EDGE NAIL ALL BRIDGE TRIMMERS. BRIDGE TRIMMER FACE (STITCH) NAILING PER SHOP DRAWINGS. REQUIRED ON TWO (2) TRIMMERS ONLY. BRIDGE LEVEL FULL HEIGHT COMPRESSION MEMBER LEVELS END OF SHEAR WALL (1) ROW OF 3" ° LENGTH x 0.131" ° DIAMETER STITCH • • NAILING AT 12" e e O.C. REQUIRED BY • IBC TABLE 2304.10.1 e • e • EDGE NAILING REQ'D • AT THE OUTERMOST • m ° STUD/POST ON ° • BOTH SIDES OF ROD ° • ANY ADDITIONAL • • STUDS/POSTS CAN e BE FIELD NAILED. ° NAILS MAY BE DISPERSED AND STAGGERED ON MULTIPLE MEMBERS. w w C:)CD z CD z Q 0 Q Cn Iz W 0 0 Cn z O_ UO > W w H- 0 0 o O Q LLJ O Iz z W � U Q \ .• 4 w � O •41 Ate;;• so � : •ter 0 l ❑ 35036 .RAL ..• .•'0��DO O000SION o000 N0 o N 0 a 0 Z O CO 0 W Z O� 0 W a C13 a= �0 = C V co i N W D O E 0-) N 0 c0 N U 10 r- • Un 0 � I I o 4 � oM°0 moo Do � X s2 � z 0 Q 0W a- C/� N 0 a N U Q) op �M 0 Cn >, 3: 0� m 7D o rc) C w0 Z 0 3 C 0 Uj EB CORP JOB N0: 19474 SHEET TITLE: EARTHBOUND SEISMIC HOLDOWN SYSTEM INSTALLATION DRAWINGS IAPMO ER-0429 DATE: FOR COMPLIANCE WITH THE APPLICABLE 0 2 /2 3 /2 0 21 ❑ BUILDING ® STRUCTURAL ❑ MECHANICAL ❑ PLUMBING ❑ ELECTRICAL ❑ ENERGY RECEIVED SHEET N 0. E] ACCESSIBILITY ❑FIRE PLAN REVIEW ACCEPTANCE OF DOCUMENTS May 11 2021 DOES NOT AUTHORIZE CONSTRUCTION TO PROCEED IN VIOLATION OF ANY FEDERAL, STATE, OR LOCAL REGULATIONS. CITY OF EDMONDS EB=1/�' DEVELOPMENT SERVICES BY: �Q+-7/�-•-`�' DATE:6/1/2021 DEPARTMENT WEST COAS CODE CONSULTANTS, INC. PATFNTS ANn PATFNTS PFNnING Fnr more infnrmntinn nhnut tha Fnrthhnund Hnlrinwn Svstam. visit httn- //www.hnIrinwn.nnm Cnnvrinht 0 ?091 _ Fnrthhnund Cnrnnrntinn_ All Rinhts RPGPrvP.d NOTE: SEE SHOP DRAWING GENERAL NOTES FOR NAILING REQUIREMENTS WHEN POSTS ARE USED. NAILING S •^, r-rF=PTAmr;= c� a z 0 o HOLDOWN RUN DETAILS *NOTE = 9'-0" TYPICAL HEIGHT 2-/2"* MAX PER FLOOR FROM PLUMB j SLACKJACKTM DEVICE/ (OR COUPLER) FLOOR ABOVE FLOOR JOIST OR SOLID BLOCKS (TYP) REF. STUDS (TYP) PLUMB SLACKJACKTM DEVICE (OR COUPLER) IT FLOOR BELOW ALLOWABLE ROD OFFSET DETAIL 2 SCALE: NONE EB-2 EB-2 NOTES: 1. SEE 23/S9.00 FOR HOLDOWN ANCHOR BOLT REINFORCING REQUIRED. 2. SEE 23/S9.00 FOR MIN. PLATE SIZE REQUIRED. 3. *** 2-1/2" AT R11 ANCHOR BOLT DIAMETER. REFERENCE STUDS ROD (R) COUPLER AB & ROD (R) FULLY SEATED IN COUPLER C0 FND. PLATE ANCHOR BOLT AS °I • SPECIFIED BY I< a STRUCTURAL PLANS. a PLATE (SIZE VARIES) ANCHOR CHAIR z ° ° LEAVE 3 THREADS MIN. OPTIONAL EXPOSED NAILS (TYP) TYP. ANCHOR BOLT INSTALLATION DETAIL r4 SCALE: NONE EB-2 EB-2 c7)n -0 CO • N N I� z 0 � N O W N 0 rrj OF) N >Q � Q) = LL 14-Y2" MAX. & END OF 8" MIN. ® SLACKJACKTM DEVICE SHEAR WAL0.L STANDARD FRAMIN PLATE TOE NAILING OPTIONAL AT IF BRIDGE BLOCK. NAILING ' MUST BE AT ABOVE 25% OF BLOCK HEIGHT ONLY. Ln o FACE NAILING EACH SIDE (TYP). SEE NOTE #17 FOR ALL REQUIREMENTS LL- LLJ BRIDGE TRIMMERS mCOUPLER (C) Q , z ROD (R) SLACKJACKTM DEVICE C°7�9Z I PLATE TYP. BRIDGE INSTALLATION DETAIL SCALE: NONE EB-2 EB-2 ANCHOR BOLT NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF WALL TYPE AND FRAMING LAYOUT BEFORE LOCATING ANCHOR BOLTS IN CONCRETE. 2. ALL DIMENSIONS ARE TYPICAL U.N.O. 9„ NOMINAL END SHEAR WALL 8-1 /2" MIN 10" MAX ANCHOR BOLT LOCATION ZONE (TYP) 7n TYP. ANCHOR BOLT PLAN DETAIL B SCALE: NONE EB-2 EB-2 RUN TYPE S1 WOOD FLOOR LEVEL UPLIFT TENSION LOADS CALCULATED DIFFERENTIAL LOADS COLLECTED DIFFERENTIAL LOADS WOOD COMPRESSION DOMMLOAD 5th 1,000 LBS 1,000 LBS 1,000 LBS 2,000 LBS 4th 2,000 LBS 1,000 LBS 1,000 LBS 5,000 LBS 3rd 6,000 LBS 4,000 LBS 4,000 LBS 11,000 LBS 2nd 10,000 LBS 4,000 LBS 4,000 LBS 17,000 LBS lot 15,000 LBS 5,000 LBS 5,000 LBS 24,000 LBS \cn V)LLJ o Q � J cn ® 2. FULL LENGTH STUD Z 2x BRIDGE TRIMMER 1 EB-2 EB-24. MOUNT AT 4'-6" ABOVE FLOORj..j BRIDGE TRIMMERS REQUIRED 1 4x WALLS: ❑2 2* J J 6x WALLS: 2* Ln ❑2 *BRIDGE TRIMMERS SHALL BE 2x MEMBERS ONLY. \cn oQ J cn IZ COLLECTOR STUDS REQUIRED 4x WALLS: 1i M -j 2 2xs TOTAL J 6x WALLS: 12" MIN. 2 2xs TOTAL MJ200 ORANGE N/A l--P6-4 (GREEN) C-4x6/6x6 BRIDGE -�72" R4 C44 MJ200 ORANGE N/A --P6-4 (GREEN) RUN TYPE S2 WOOD FLOOR LEVEL UPLIFT TENSION LOADS CALCULATED DIFFERENTIAL LOADS COLLECTED DIFFERENTIAL LOADS WOOD COMPRESSION DOWNLOAD 5th 1,000 LBS 1,000 LBS 1,000 LBS 2,000 LBS 4th 5,000 LBS 4,000 LBS 4,000 LBS 6,000 LBS 3rd 10,000 LBS 5,000 LBS 5,000 LBS 12,000 LBS 2nd 16,000 LBS 6,000 LBS 6,000 LBS 19,000 LBS lot 23,000 LBS 7,000 LBS 7,000 LBS 27,000 LBS \cn V)LLJ o Q J (n 0- ® 2. FULL LENGTH STUD 2, BRIDGE TRIMMER 1 EB-2 EB-2 If MOUNT AT 4'-6" ABOVE FLOOR BRIDGE TRIMMERS REQUIRED 4x WALLS: � ❑2 2* J 6x WALLS: 2* j ❑2 *BRIDGE TRIMMERS SHALL BE 2x MEMBERS ONLY. R4 I \cn C54 o­- SJA225 cf) a- YELLOWI BLACK LL LL 0 � P6 (GREEN) COLLECTOR STUDS REQUIRED 4x WALLS: 1T M 3 2xs TOTAL J 6x WALLS: 12" MIN. -c 2 2xs TOTAL '1 MJ200 /I - ORANGE N/A �P6-4 (GREEN) r-4x6/6x6 BRIDGE --72" R4 C54 SJA225 YELLOW BLACK --P6 (GREEN) RUN TYPE S3 WOOD FLOOR LEVEL UPLIFT TENSION LOADS CALCULATED DIFFERENTIAL LOADS COLLECTED DIFFERENTIAL LOADS WOOD COMPRESSION DOWNLOAD 5th 2,000 LBS 2,000 LBS 2,000 LBS 3,000 LBS 4th 7,000 LBS 5,000 LBS 5,000 LBS 9,000 LBS 3rd 15,000 LBS 8,000 LBS 8,000 LBS 17,000 LBS 2nd 24,000 LBS 9,000 LBS 9,000 LBS 26,000 LBS lot 33,000 LBS 9,000 LBS 9,000 LBS 36,000 LBS 2. F .. _. 2, E MO \n w TR c o Li 4x �a C/-) J 0 J 6x Ln ❑2 *BRIDGE BE 2x R5 I \Cn C65 o­- SJA226 c~n a- YELLOW GRAY LL LL 0 0 P6 (GREEN) O 4x J 4 6x -c 1 r 2 MJ200 ORANGE N/A P6-4 (GREEN) 4x6/6x6 BRIDGE 72" R4 C54 SJA225 IYELLOWI BLACK P6 (GREEN) R5 C85 SJA428 GREEN IYELLO111 P8 (BLACK) z 0 a_ U Cn W Ld H- 0 Cn z 0 W COLLECTOR COLLECTOR COLLECTOR STUDS REQUIRED STUDS RE UIRED STUDS RE UIRED \NCD 4x WALLS: \� : 4x WALLS: \� 4x WALLS: 12" MIN. R5 V) w I R6 12" MIN. R8 12" MIN. cn w I Q °' + C65 Q °'+ C86HS Q C98HS ) � 5 2xs TOTAL SJA216 w J 5 2x's TOTAL j 4x6 4x6 14-1 "MAX ® > 6x WALLS: > 6x WALLS: SJA218 w J 6x WALLS: SJA419 O /2 o p J 12" MIN. BLUE GRAY o p J 12" MIN. BLUE YELLOW o p 12" MIN. RED WHITE NOTE: SOLID BLOCKING, PROVIDE ENOUGH SOLID STANDARD FRAMING TM �; ��- 11 P10-9 z BLOCKING IN JOIST SPACE TO MATCH WIDTH OF SLACKJACK DEVICE +1111 P6 P6 3 2x's TOTAL I (GREEN) 3 2xs TOTAL I (GREEN) 4 2xs TOTAL I (BLUE) ALL COMPRESSION STUDS OR POSTS OF THE i WALL BELOW. END OF COLLECTOR I 3 COLLECTOR I 3 COLLECTOR I 3 STUDS REQUIRED STUDS REQUIRED STUDS REQUIRED SHEAR WALL PLATE \cn o 4x WALLS: TYP \� 0 4x WALLS: TYP \cn 0 4x wALLs: R9 TYP cn Lw I 12" MIN. R 6 CO Lw 1 12" MIN. R 8 (n Li I 12" MIN. 14- W' MAX ® Q °� Q °� Q °� v 0 (n J C86HS (n J C98HS FL J 4x6 4x10 C109HS W 0 � LLJ > z STANDARD FRAMING � W � 4x6 4x6 � W � 4x6 4x6LLJ TM w Ll J 6x WALLS:TFIVI SJA21 8 w w J 6x WALLS: SJA219 LL J 6x WALLS: SJA4110 z� z Q W a O SLACKJACK DEVICE p p 12" MIN. BLUE YELLOW o 0 12" MIN. BLUE WHITE o 0 12" MIN. RED GREEN CD z SOLID BLOCKING >�� o �� o >�� C� U W' w Q PER STRUCT. ENGR. N + P6 N + P8-9 N P10-10 Q Cn W END OF REQUIREMENTS. 4 2x's TOTAL (GREEN) 4 2xs TOTAL (BLACK) 6 2x's TOTAL (BLUE) LLJ = SHEAR WALL PLATE < W COLLECTOR COLLECTOR COLLECTOR 0 0 U Q STUDS RE UIRED SOLID STUDS RE UIRED SOLID STUDS RE UIRED SOLID d 4x wALLs: B LK G 4x WALLS: B LK G 4x wALLs: B LK G 0 12" MAX. (TYP) 0 12" MAX. (TYP) 0 12" MAX. (TYP) (2) 2x PLATES \cn 9" \cn s" \cn 9" cn w -1 12' R8 cn w 1 12' R9 w 1 R10HS z SOLID BLOCKING ROD (R) Q + ~ + Q PER STRUCT. ENGR. J J 4xE 4x10 J J 4x6 2 4x6s J J 4x6 2 4x8 s W J > 6x WALLS: > 6x WALLS: cn > 6x WALLS: REQUIREMENTS. J C98HSG J C119HSG JCl110HSG �AMO M �O wr'_ ; o 12�"MAX. B o 12K2xE+;TO MAX. B o cn 12" „MAX. B O�OO : .� W �w„ AT GREATER NUMBER OF COMPRESSION + I EB-2 EB-2 I EB-2 EB-2 2) 2x PLATES STUDS FROM LEVEL BELOW 5 2xs TOTAL a I TAL + I 6x6 6x6 + I ❑ o "l ❑ ( ) AB PLT: AB: R9G AB PLT: AB: R11 G AB PLT: AB: R11 G ROD R TM 1 %4" SQ. 4 1 "x5" SQ. 4 1 "x5" SQ. 4 4 3503s ORAL .. I�QO TYP. SLACKJACK INSTALLATION - - - - - - - - - °o1��F �,x�`� 0 1 AT EQUAL NUMBER OF COMPRESSION DETAIL 3 CHR. HT: 1-1 /2" EB-2 EB-2 CHR. HT: 2-1 /2" EB-2 EB-2 CHR. HT: 2-1 /2" EB-2 EB-2 �0�� oN0000Oo STUDS FROM LEVEL BELOW & ABOVE SCALE: NONE EB-2 EB-2 S2 S3 PLAN REVIEW ACCEPTANCE FOR COMPLIANCE WITH THE APPLICABLE CONSTRUCTION CODES IDENTIFIED BELOW. El BUILDING ®STRUCTURAL ❑ MECHANICAL ❑ PLUMBING ❑ ELECTRICAL ❑ ENERGY ❑ ACCESSIBILITY ❑ FIRE PLAN REVIEW ACCEPTANCE OF DOCUMENTS DOES NOT AUTHORIZE CONSTRUCTION TO PROCEED IN VIOLATION OF ANY FEDERAL, STATE,,, OR LOCAL REGULATIONS. BY: �I��/- DATE.6/1/2021 WEST COAS CODE CONSULTANTS, INC. � N 0 c0 N U (D r- Ln O � I I o ­t 0 -0 cy) 00 0 co 00 N � °° I� X 00 d� az Q n, 0 (W c f) a- N O a 00 U 00 ZZ � Q O 0� O m � 7D U m � � 0 0 0 W Z� G O � z Wa o 0 3 w V ~ X3 3 0 = o DC _C Q = N Lu w 0 EB CORP JOB NO: 19474 SHEET TITLE: EARTHBOUND SEISMIC HOLDOWN SYSTEM INSTALLATION DRAWINGS IAPMO ER-0429 DATE: RECEIVED 02/23/2021 May 11 2021 CITY OF EDMONDS SHEET NO. DEVELOPMENT SERVICES DEPARTMENT EB=2 PATFNTS AN0 PATFNTS PFNnING Fnr mnrP infnrmntinn nhnut tha Fnrthhnunct Hnldnwn Svstem_ visit httn: //www.hnlctnwn.nnm Cnnvrinht 0 2021 _ Fnrthhnund Cnrnnrntinn_ All Rinhts RPGPrveci_ 7 F E D C C B A CA .7. KEY PLAN LEVEL Rl WOOD FRAMING PLAN -NORTH Cl O O Ee 0 (ED 06 5600-02 Holdowns - Calcs & Shop Drawings CO MUT S CS R CR C QQ P N OOO � (l)--- 4) LEV PLAN REVIEW ACCEPTANCE FOR COMPLIANCE WITH THE APPLICABLE CONSTRUCTION CODES IDENTIFIED BELOW. ❑ BUILDING ® STRUCTURAL ❑ MECHANICAL ❑ PLUMBING ❑ ELECTRICAL ❑ ENERGY ❑ ACCESSIBILITY ❑ FIRE PLAN REVIEW ACCEPTANCE OF DOCUMENTS DOES NOT AUTHORIZE CONSTRUCTION TO PROCEED IN VIOLATION OF ANY FEDERAL, STATE, OR LOCAL REGULATIONS. BY: t�*7!� DATE:6/l/2021 WEST COAS CODE CONSULTANTS, INC. RECEIVED May 11 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0t'1 06 5600-02 Holdowns - Calcs & Shop Drawings RECEIVED BY CKC Feb 26, 2021