APPROVED BLD PLN BLD2023-0869+Building_Elevations+7.12.2023_8.45.36_AM+3660329ABBREVIATIONS GENERAL -LEGEND PROJECT DESCRIPTION � DIAMETER RTU EQUIPMENT TAG TYPE ABV ABOVE 2 EQUIPMENT TAG NUMBER ACH AIR CHANGES PER HOUR AD ACCESS DOOR 1 DETAIL OR DIAGRAM NUMBER AFF ABOVE FINISHED FLOOR M2.1 SHEET NUMBER WHERE DETAIL SHOWN AFG AVERAGE FINISHED GRADE AFUE ANNUAL FUEL UTILIZATION EFFICIENCY 1 SECTION LETTER AHU AIR HANDLING UNIT M2.1 SHEET NUMBER WHERE SECTION SHOWN AHRI AIR CONDITIONING, HEATING REFRIGERATION INSTITUTE AP ACCESS PANEL � � REVISION CLOUD AND CHRONOLOGICAL NUMBER ARI AMERICAN REFRIGERATION INSTITUTE BHP BRAKE HORSEPOWER DETAIL REFERENCE OUTLINE BDD BACKDRAFT DAMPER BOD BOTTOM OF DUCT � POINT OF CONNECTION TO EXISTING OR TO BF BELOW FLOOR OTHERS' WORK BOT BOTTOM BTU(H) BRITISH THERMAL UNIT (HOUR) O1 KEY NOTE CALLOUT CD CONDENSATE CFM CUBIC FEET PER MINUTE 1Q PHOTO ID CALLOUT CONN CONNECTION COP COEFFICIENT OF PERFORMANCE ' ' ' ' ' WORK TO BE REMOVED DB DRY BULB/DECIBELS HVAC - L E G E N D DIBFF D FFIERENTIAL DN DOWN DR DRAIN �► AIR FLOW DIRECTION E EXISTING EA EACH OR EXHAUST AIR SUPPLY OR OSA DUCT SECTION UP, ROUND OR EAT ENTERING AIR TEMPERATURE � � RECTANGULAR EC ELECTRICAL CONTRACTOR EER ENERGY EFFICIENCY RATIO RETURN, RELIEF OR EXHAUST DUCT SECTION UP, EF EXHAUST FAN � � ROUND OR RECTANGULAR EFF EFFICIENCY EG ELEV EXHAUST GRILLE ELEVATION 0 � SUPPLY OR OSA DUCT SECTION DOWN, ROUND OR RECTANGULAR EQUIP EQUIPMENT ESP EXH EXTERNAL STATIC PRESSURE EXHAUST 0 � RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN, ROUND OR RECTANGULAR EXIST EXISTING F FURNACE EXISTING DUCTWORK °F FAHRENHEIT FF FINISHED FLOOR SLSM SOUND LINED SHEET METAL FLA FULL LOAD AMPERAGE FPM FEET PER MINUTE � FC FLEXIBLE EQUIPMENT CONNECTION FREQ FREQUENCY FT FOOT OR FEET ° SFD COMBINATION FIRE AND SMOKE DAMPER G NATURAL GAS HP HORSEPOWER OR HEAT PUMP FD FIRE DAMPER HR HOUR HSPF HEATING SEASONAL PERFORMANCE FACTOR SD SMOKE DAMPER HT HEIGHT HVAC HEATING, VENTILATING, AIR-CONDITIONING EVADE VOLUME DAMPER HZ HERTZ IBC INTERNATIONAL BUILDING CODE M MD MOTORIZED DAMPER ID INSIDE DIAMETER IEER INTEGRATED ENERGY EFFICIENCY RATIO IFC INTERNATIONAL FIRE CODE � TURNING VANES IFGC INTERNATIONAL FUEL GAS CODE IMC INTERNATIONAL MECHANICAL CODE IN INCHES ROUND TO ROUND 45° FITTING IN WG INCHES WATER GAUGE KW KILOWATT LAT LEAVING AIR TEMPERATURE/LATITUDE SQUARE TO SQUARE 45° FITTING LBS POUNDS LIN FT LINEAR FOOT OR FEET LRA LOCKED ROTOR AMPS SQUARE TO ROUND 45° FITTING MAX MAXIMUM MBH 1,000 BTU PER HOUR MCA MINIMUM CURRENT AMPS VD 45° FITTING FOR DUCTWORK MFR MANUFACTURER MIN MINIMUM GAS PIPING MOCP MAX OVER CURRENT PROTECTION NEC NATIONAL ELECTRICAL CODE Oc CARBON MONOXIDE SENSOR NIC NOT IN CONTRACT NOM NOMINAL O COORDINATED POWER LOCATION OD OUTSIDE DIAMETER/DIMENSION OPTS OPTIONS O REMOTE SENSOR OSA OUTSIDE AIR PH ELEC POWER PHASE (1 � OR 3�) O THERMOSTAT PN PROJECT NORTH (REFERENCE) POC POINT OF CONNECTION PRESS PRESSURE CO M M I SS I O N I N G PSI POUNDS PER SQUARE INCH RA RETURN AIR OR RELIEF AIR MECHANICAL SYSTEM S RD ROOF DRAIN REF REFERENCE COPIES OF ALL APPLICABLE SERVICE AND EQUIPMENT DATA, AS WELL AS RPM REVOLUTIONS PER MINUTE PROJECT DOCUMENTATION THAT RELATES, SHALL BE PROVIDED TO THE RTU ROOFTOP UNIT OWNER AND MADE AVAILABLE TO THE AUTHORITY HAVING JURISDICTION (AHJ SA SUPPLY AIR WITHIN 90 DAYS OF PROJECT COMPLETION AND IN ACCORDANCE WITH 2�,5 v'� SEER SEASONAL ENERGY EFFICIENCY RATIO WSEC SECTION C408.1, INCLUDING: SF SUPPLY FAN OR SQUARE FOOT OR FEET SMACNA SHEET METAL NATIONAL ASSOCIATION THE PROJECT IS A LIKE -FOR -LIKE, ONE (1) SPLIT SYSTEM HEAT PUMP REPLACEMENT FOR A RESIDENTIAL SPACE, WITHIN ATHREE-STORY ASSISTED LIVING BUILDING. THE BUILDING IS SITED WITHIN THE CITY OF EDMONDS (JURISDICTION), SNOHOMISH COUNTY, WASHINGTON. MECHANICAL PERMIT: UNDER APPLICATION RELATED ELECTRICAL PERMIT: UNDER SEPARATE PERMIT GENERAL NOTES 1. COORDINATE ALL NEW WORK WITH STRUCTURE AND OTHER TRADES. 2. FIELD VERIFY UNIT LOCATIONS, DROPS AND POSITIONS. 3. ALL LINE VOLTAGE WORK SHALL BE INSTALLED BY AN LICENSED COMMERCIAL ELECTRICIAN. 4. HVAC SYSTEMS HAVE BEEN DESIGNED PER THE REQUIREMENTS OF 2015 WSEC, IBC AND IMC. 5. ALL RIGGING AND LIFTING TO BE COORDINATED WITH THE BUILDING OWNERSHIP AND ANY OTHER CITY AND LOCAL JURISDICTIONS. APPLICABLE CODES 1. 2018 WASHINGTON STATE ENERGY CODE (WAC) CHAPTER 51-11) 2. 2018 INTERNATIONAL BUILDING CODE (WAC CHAPTER 51-50) 3. 2018 INTERNATIONAL MECHANICAL CODE (WAC CHAPTER 51-52) 4. 2018 INTERNATIONAL FUEL GAS CODE (WAC CHAPTER 51-52) 5. 2018 UNIFORM PLUMBING CODE (WAC CHAPTER 51-56) 6. NATIONAL ELECTRICAL CODE (NFPA 70 -WAC CHAPTER 296-46B) CODE COMPLIANCE NOTES 1. PROGRAMMABLE CONTROLS SHALL BE CAPABLE OF PROVIDING 5 DEGREE DEAD BAND AS REQUIRED BY 2018 WSEC SECTION C403.2.4.1.2. CONTROLS SHALL ALSO BE CAPABLE OF PROVIDING SEVEN DAY PROGRAMMABLE TEMPERATURE SETTINGS, AUTOMATIC SETBACK AND SHUTOFF AND OPTIMUM START AS REQUIRED BY 2018 WSEC SECTION C403.2.4.2 (OFF -HOUR CONTROLS). CONTROLS SHALL BE CONFIGURED TO PREVENT SIMULTANEOUS HEATING AND COOLING. 2. REPLACEMENT SPLIT SYSTEM AIR CONDITIONER IS OF THE SAME TYPE AND OUTPUT CAPACITY. 3. THIS PROJECT MEETS THE 2018 WSEC MINIMUM EFFICIENCY REQUIREMENTS FOR COOLING PROVIDED BY ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS PER TABLE C403.2.3(2)A WITH A SEER OF 12.2, WHICH MATCHES THE MINIMUM REQUIREMENT OF 11.2 SEER FOR EQUIPMENT SIZE CATEGORY <65 MBH (UNITARY AIR CONDITIONERS, SPLIT SYSTEM). MECHANICAL SCOPE THE PROJECT IS FOR THE REPLACEMENT OF ONE (1) EXISTING SPLIT SYSTEM HEAT PUMP HVAC UNIT. THE EXISTING SYSTEM HAS REACHED THE END OF IT'S USEFUL LIFE. THE NEW SYSTEM IS THE SAME TYPE AND SAME NOMINAL OUTPUT CAPACITY: 1. DEMO THE (1) OAC-1 EXISTING ROOFTOP HVAC UNIT 8c HEAT PUMP SERVING ROOM 202. 2. THE REMOVAL AND DISPOSAL OF THE EXISTING UNITS FROM BUILDING SHALL BE IN A LAWFUL MANNER. RECLAIM EXISTING REFRIGERANT PER EPA STANDARDS; R-22 IS EXISTING REFRIGERANT PER EQUIPMENT NAME PLATE DATA. 3. PROVIDE AND INSTALL ONE (1) ROOFTOP HP UNIT & (1) FAN COIL IN PLACE OF THE EXISTING UNITS PER PLAN. NEW EQUIPMENT INCLUDES ELECTRIC DX COOLING, &BASIC ELECTRO-MECHANICAL CONTROLS. 4. DISCONNECT AND RE -CONNECT REPLACEMENT OAC & IFCU TO EXISTING ELECTRICAL SERVICES. RE -USE EXISTING ELECTRICAL DISCONNECT WHERE PRACTICABLE. LINE VOLTAGE WORK SHALL BE BY LICENSED COMMERCIAL ELECTRICIAN (UNDER SEPARATE PERMIT). 5. REUSE EXISTING THERMOSTAT AND CONTROL WIRING. 6. EQUIPMENT AND SYSTEM START-UP, TEST AND BALANCE, PROGRAMMING AND OWNER TRAINING FOR NEW EQUIPMENT, 0&M MANUALS AND RECORD DRAWINGS. 7. THERE IS AN EXISTING ±48" HIGH PERIMETER PARAPET WALL SURROUNDING ALL OF THE MECHANICAL EQUIPMENT ON THE ROOF. NO SCREENING IS NECESSARY. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED ( ) 1. PRELIMINARY COMMISSIONING REPORT AND OTHER RELATED REPORTS PLANS MUST B E T TON 1 TON = 12,000 BTUH SUCH AS AIR BALANCING, START-UP AND/OR PRESSURE TESTING DATA. TN TRUE NORTH (REFERENCE) T-STAY THERMOSTAT 2. RECORD DRAWINGS DEPICTING FINAL INSTALLATION CONFIGURATIONS OF TYP TYPICAL SYSTEMS AND EQUIPMENT. ULL ULTRA LOW LEAK DAMPER UNO UNLESS NOTED OTHERWISE 3. OPERATION AND MAINTENANCE EQUIPMENT MANUALS INCLUDING: UPC UNIFORM PLUMBING CODE MANUFACTURER'S INFORMATION WITH SPECIFIC MODEL NUMBERS AND W WATTS/WIDTH/WINDOW OPTIONS NOTED, CONTROLS DATA INCLUDING CALIBRATION AND SET WB WET BULB POINT INFORMATION, AND A SIMPLE NARRATIVE DESCRIPTION OF EACH WSEC WASHINGTON STATE ENERGY CODE SYSTEM. COPIRIGHT 2023 PINEHURST ENGINEERING, PLLC ON JOB SITE City Of Edmonds Building Department Work MECHANICAL- RTU Address � �0 EDMONDS WAY Owner SUNRISE OF EDMONDS ' Approved Date 07/17/2023 Building Official Eri,c� � Permit Number BLD2023-0869 APPROVED BY PLANNING C�v�- � /C�%G�� Jul 25 2023 REVISIONS DATE PAGES CHANGES REV1 REV2 REV3 REV4 REVS VICINITY MAP (BY GOOGLE MAPS, NOT TO SCALE) � PROJECT LOCATION - 750 EDMONDS WAY, EDMONDS f� -�: �' .� � t�. � ' � S t.� � � � '. i , My w � ,�� � .5 { i �. � a � - � �' r *� �� ` V f'� '. ' - r + ., ,� � � �� �� _ 4 r IA 'y � yy � x r a °f i ':�� ' ' SITE MAP (BY GOOGLE MAPS, NOT TO SCALE) I I\VULIiI LVV/'111VIV - `I� I\VVI I VI VIVI I I V UL I\LI L/"�VLU BUILDING INFORMATION LEGAL DESCRIPTION PROJECT ADDRESS: SUNRISE OF EDMONDS 750 EDMONDS WAY, EDMONDS, WA. 98020-5126 SITE CONTACT: RICHARD (425) 673-9700 PROPERTY OWNER: HCP SUN1 EDMONDS WA LLC., 2235 FARADAY AVE, SUITE �0, CARLSBAD, CA. 92009 TAX PARCEL NUMBER: 27032500306200 CONSTRUCTION TYPES: 11 - 1 HR FULLY SPRINKLERED PRIMARY OCCUPANCIES: CONVALESCENT CENTER ORIGINAL CONSTRUCT: 2004 TOTAL BUILDING AREA: 60,052 SF CLIMATE ZONE: 4C-SNOHOMISH THIS ASSISTED LIVING RESIDENTIAL PROPERTY HAS A SINGLE INSTUTUTIONAL RELATED OCCUPANCY AND BUILDING IDENTIFICATION ASSOCIATED WITH IT. ADDITIONAL PROPERTY AND BUILDING DATA CAN BE FOUND FROM THE CITY OF EDMONDS AND SNOHOMISH COUNTY ASSESSORS MAPS. DRAWING INDEX PAGE � SHEET � SHEET TITLE SCALE 1 M0.1 COVER SHEET, LEGEND AND NOTES N/A 2 M0.2 EQUIPMENT SCHEDULES 8c DATA N/A 3 M0.3 EQUIPMENT DATA N/A 4 M 1.1 ROOF PLAN -MECHANICAL 1 /8" = 1'-0" 0 SEC 25 TWP 27 RGE 03 TH PTN SW1/4 SE1 /4 SW1 /4 DAF: BEG SW COR SD SUB;TH N01 *00 36E ALG W LN 60.6FT TH N60*11 41 E 358.30 FT TO SWLY MGN OF SR-104 (EDMONDS WAY) AS CONVD PER DEED REC AF2180193; THS39*05 51 E PLW & 40FT SWLY C/L SR-104 ALG SWLY MGN AS CONVD TO ST OF WA BY DEEDS REC AFN'S 2180193, 2181901 & 2185476 DIST OF 201.69FT TAP OPST HWY ENGR STA 97+85; TH S01 *05 34W ALG SD MGN DIST OF46.49FT TAP 30FT NWLY & OPST HES 0-70; TH N88*29 44W DIST OF 382.17FT TO POB; PER CITY OF EDM LL-2000-134 REC AFN200303175004 0 4' 8' 16' �� SCALE: 1/8" = 1'-0" w � � L �� m: N Cn � F � � � Q z � � O N O QZ� C �- �N � = M � C U wQ °O w �=, u.i F U � � Z pW � =w �� 3� ~ om Q L �� �- 5 �� � o ti � r+ � � 0� O �� Z OQNER"T���M'9� •:.; of wasy�;�; �� FG/STER..••' �p ���oa00000���� _ � 23 EXPIRES: 10�25�24 Q WQo w 3 °' OQ3 z Q �Qo oQ ��w RECEIVED Jul 12 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT M0.1 COVER SHEET LEGEND AND NOTES PROJECT NO. 02Q-Q']g 7/4/23 OUTDOOR HEAT PUMP EQUIP NO. SERVICE CONNECTED INDOOR UNIT NOMINAL CAPACITY, TONS TOTAL COOLING CAPACITY, BTUH SEER ELECTRICAL DATA SOUND POWER, DBA WEIGHT, LBS BASIS OF DESIGN (1) (2) (3) (4) VOLTAGE MOCP OHP-202 RM 202 FCU-202 1.5 18,000 15 230V/1 P 20 71 140 CARRIER 25SCA518A003 OHP (1) ARI LISTED WITH STANDARD FEATURES, INSTALLATION ACCESSORIES AND COMPRESSOR SHORT CYCLING 202 PROTECTION, FILTER DRIER, REFRIGERANT LINE FILTER, LIQUID SOLENOID VALVE AND SAFETY PRESSURE SWITCHES. INSTALL REFRIGERANT TUBING AND LENGTH IN STRICT ACCORDANCE WITH MANUFACTURERES RECCOMENDATIONS. (2) WITH FACTORY OPTION DISCONNECT. (3) PROVIDE ALL REQUIRED ACCESSORIES FOR LONG -LINE AND LOW -AMBIENT APPLICATIONS. (4) ROUTING OF REFRIGERANT LINES FROM INDOOR TO OUTDOOR UNITS NOT SHOWN ON PLANS. CONTRACTOR TO FIELD COORDINATE ROUTING. FCU 202 HEAT PUMP COIL (�) EQUIP NO. SERVICE COIL CONFGURATION SUPPLY FAN COOLING CAPACITY, TONS AUX ELEC HEAT KW ( 230 V) ELECTRICAL DAT WEIGHT, LBS BASIS OF DESIGN AIRFLOW, CFM ESP, IN WC MIN OSA (CFM) MOTOR HP VOLTAGE MOCP FCU-202 RM 202 VERTICAL 600 0.5 75 1/3 1.5 2.3 208V/1 P 20 120 CARRIER FJ4DNXA18L00 NOTES: (1) PROVIDE CONDENSATE DRAIN TO NEAREST APPROVED RECEPTOR. PROVIDE CONDENSATE PUMP IF REQUIRED. Unit Report For 1.5T SS HP-SEER2 'roject: Sunrise Edmonds-1.5T SS HP 05/15/202: 'repared By: Performance Summary For 1.5T SS HP-SEER2 'roject: Sunrise Edmonds-1.5T SS HP 05/15/202; 'repared By: System Performance System: 25SC:A/FJ4D Actual Clg Airflow: 600.0 CFM ��"�- __ System Quantity: 1 Standard Clg Airflow: 600.0 CFM _ __ _ � Altitude: 0.0 ft Total Net Clg Capacity: 17.20 MBH i�. Linear Pipe Length: 0.0 ft Net Sensible Clg Capacity: 13.10 MBH I COP @ 47 F: 3.56 Htg HP Capacity: 17.50 MBH ' COP @ 17 F: 2.42 Htg HP Integrated Capacity: 17.50 MBH j '� � SEER2 @ARI Conditions: 14.3 Total System Power: 1.44 kW r�'' EER2 @ARI Conditions: 12.0 HSPF2 @ARI Conditions: 7.5 �� i System Parameters Outdoor Unit Parameters Indoor Coil Parameters Unit Model: 25SCA Unit Model: FJ4D Outdoor Unit Parameters Indoor Coil Parameters Unit Size: 1.5 Tons (Size 18) Unit Size: 18,000 Btuh (Size 18) Unit Model: 25SCAEi18A003 Unit Model: FJ4DNXA18L00 Voltage: 208/;>_30-1-60 V-Ph-Hz Cabinet Width: TXV/ 14 Inches Cabinet Unit Size (Nominal): 1.5 Tons (Size 18) Unit Size (Nominal): 18,000 Btuh (Size 18) Voltage: 208-1-60 V-Ph-Hz Voltage: 208/:?30-1-60 V-Ph-Hz Voltage: 208-1-60 V-Ph-Hz Heating Size: No Heat Clg Ent Air DB Ambient: 95.0 °F Ent Air DB: 80.00 °F Htg Ent Air DB Ambient: 47.0 °F Ent Air WB: 67.00 °F Outdoor Unit Dimensions and Weight Indoor Coil Dimensions and Weight Ent Enthalpy: 31.44 BTU/Ib Unit Length: 31.1875 in Unit Length: 22.0625 in Lvg Air DB: 59.78 °F Unit Width: 31.1875 in Unit Width: 14.3125 in Lvg Air WB: 58.06 °F Unit Height: 28.6875 in Unit Height: 42.6875 in Lvg Enthalpy: 25.07 BTU/Ib Unit Shipping Weight: 170. Ib Unit Shipping Weight: 120. Ib Htg Ent Air DB: 70.0 °F Htg Lvg Air DB: 97.0 °F RESIDENTIAL APPLICATIONS Heating Size (Nominal): No Heat This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and Total External Static Pressure: 0.50 in wg below. The limited warranty period in years, depending on the part and the claimant, is as shown in the table below. Limited Warrant Years Item Original Owner Subsequent Owner Parts 10* or 5 5 Compressor 10� (or 5) 5 'If properly registered within 90 days of origlinal installation, otherwise 5 years (except in California and Quebec and other jurisdictions that prohibit warranty benefits conditioned on registration). See Warranty Conditions below. OTHER APPLICATIONS The warranty period is five (5) years on the compressor, and one (1) year on all other parts. The warranty is the original owner only and is not available for subsequent owners. Ordering Information Part Number Description Quantity Outdoor Unit 25SCA518A003 25SCA Comfort Single Stage Heat Pump with Puron Refrigerant 1.5 Tons Coolin 1 15 SEER ARI Conditions Accessories KAACH1701AAA Crankcase Heater for Outdoor Unit 1 KSAFT0101AAA Eva orator Freeze Thermostat for Outdoor Unit 1 Indoor Coil FJ4DNXA18L00 FJ4D Base Series Fan Coil with Puron 18000 BTU Cooling 208/230-1- 60 1 TXV/ 14 Inches Cabinet Aluminum Accessories Residential Carrier Products Bldr 1.37 rage � ui i i Electrical Data Outdoor Electrical Data Indoor Electrical Data Unit Voltage: 208/:?30-1-60 V-Ph-Hz Unit Voltage: 208-1-60 V-Ph-Hz Fan Motor FLA: 0.50 Amps Motor HP: 1/3 HP MCA: 13.4 Amps Motor FLA: 2.9 Amps Max Fuse: 20 Amps Operating Range Min: 197 V Accessory Electric Heater Data Operating Range Max: 253 V EH Part Number: KFFEH8401NO3 Compressor RLA: 10.3 Amps Electric Heater kW: 2.3 kW Compressor LRA: 45.7 Amps For 2 wire operation (single circuit): Heater Amps: 10.7 Amps Heater +Motor MCA: 17 Amps Heater +Motor MOCP: 20 Amps Accessory Voltage: 208-1-60 V-Ph-Hz The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHIRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 UNIT DATA r ayc J VI � � GENERAL NOTES 1. DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW SPLIT SYSTEM IS REPLACING THE SAME TYPE AND CAPACITY SPLIT SYSTEM IN THE SAME LOCATION, UTILIZING EXISTING POWER SUPPLY AND DUCTWORK. 4. NEW OUTDOOR HEAT PUMP IS SAME WEIGHT AS EXISTING. Acoustic Summary For 1.5T SS HP-SEER2 'roject: Sunrise Edmonds-1.5T SS HP 05/15/202; 'repared By: Outdoor Unit Parameters: Unit Model: Unit Size: Variations: 25SCA 1.5 Tons (Size 18) Standard Octave Band Center Fre uenc , Hz 125 250 500 1 k 2k 4k 8k dBA Sound Power,dB 70.2 66.4 65.1 67.4 62.8 58.2 52.5 A -Weighted Sound Power, dBA 71.0 Indoor Coil Parameters: Unit Model: Unit Size: Cabinet Width: FJ4D 18,000 Btuh (Size 18) TXV/ 14 Inches Cabinet Octave Band Center Fre uenc , Hz 63 125 250 500 1 k 2k 4k Sound Power,dB 70.8 66.8 62.8 59.8 57.8 55.8 51.8 The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 r ayc v vi i i m, CV i �I �� �; O LL i �: o� U wl �� z, U_ I J I a v- NER Ti��M-� °e••���FwAs����•�� ��:? �, � A •.,�QFC45976 F,O •.•' � �� OO'ppF ... /STER,.� ��,�0 ���osoalloaoNo���� - `� 23 ExPIREs: 10/25/24 O �" O Q 3a q3 00 wo 00 �� RECEIVED Jul 12 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT M 0.2 EQUIPMENT SCHEDULES & DATA SHEETS PROJECT NO. Q2Q_Q%g COPIRIGHT 2023 PINEHURST ENGINEERING, PLLC 0 4' 8' 16' `� I SCALE: 1/8" = 1'-0" 7/4/23 Certified Drawing For 1.5T SS HP-SEER2. Project: Sunrise Edmonds-1.5T SS HP 05/15/2023 Pre ared B Outdoor Model Unit Model: Unit Size: Voltage: SEER: PartNumber: A :o. AIR 019CHAAGE fi � FIELD PO'NEA SUPPiT CONK. t1B-f�tt.2t HOLE BI1H AIR IN- 1 119"1�29.6F KNOCKOUT FIEID CONTAOI S PPIt CONM. 1pT78't�22.2) MOLE �318'f�4.5) K Lrou)D uaE EDNN. 3 3f+" 3 !2' 191,0) IBT.9t I tt - �i ��� "jT � (•,VAPOR LINE CONN.I 1 131tfi• i� f /6.7) / j" G j- NOTES: I1� X SO. t. ALLOW 24' {fi09.6} CLEARANCE TO SERVECE SI[7E OF UNIT, 4$' {1218.2}ABOVE UNR. 2 CEDITER OF GRAVITY � . 2 1311i' 6" {162.4j ON ONE SIDE, 1T {3O/.B) ON REMAWING SDE, AN024" (609.6) t3ETWEEN ! T1.I1 UNITS FOR PROPER AIRFLOW. 1 SERIES CIESIGNAT10P16 Tr+E 73TH POSRION OF THE UNIT MODEL NUMBER 25SCA 1.5 Tons (Size 18) 2081230-1-60 V-Ph-Hz 15 25SCA518A003 Shipping Dimensions and Weights Outdoor Unit Hei ht 33.94 in Width 34.25 in Len th 34.25 in O eratin Weii ht 140.Ib Shipping Weight 170. Ib Dimensions A B C D E F G H I J K 31.19 in 28.69 in 0.63 in 6.56 in 24.70 in 9.13 in 1.13 in 3.81 in 14.75 in 16.25 in 13.50 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the I<Itest product literature and the AHRI directory at ***.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 Page 7 of 11 Certified Drawing For 1.5T SS HP-SEER2; Project: Sunrise Edmonds-1.5T SS HP 05/15/2023 Pre ared B NOTES: I. CONDENSATE PAN DRAIN CAPS NOT SHOwN FOR CLARITY. 2. ALL DIMENSIONS ARE IN 'INCHES" UNLESS NOTED. '� 112' TYP.► i18" TYP.t Indoor Coil Unit Model: Unit Size: Voltage: PartNumber: PRIMARY ORA SECONDARY ORAIN- HORIl, LEFT (@S SHIPPEDI PRINARI' DRAI SECONDARY DRAI 113116' TYP. t �I1d' 1SIIE" , TrP.t1 - 1518' 2 i18' 2 9YIS" TYP, l2 PLACESI► FJ4D 18,000 Btuh (Size 18) 208-1-60 V-Ph-Hz FJ4DNXA18L00 1! 16' TYP. �IPFL(A 12 PLACES)► I' TYP. l2 PLACESI+ L PE I L AIRFLOW + lll6" iYP. PLACES)+ PRIMARY DRAI SECONDARY DRAIN SI I6' TYP. t SECONDARY DRAI • ® PRIMARY DRAI �2 118" �• 1, I � lYl6' TYP. I IN"II L 2 9116" l2 PLACESIr U PLACESI► 113f l6' - i 114 iYP.+ UPFLOW DOWNFLOW (AS SHIPPEDI (FIELD CONVERTEDI R ', I �. d --t �. it 1 2118" 1114" TYP.+ ll8' F TYP.+ HORIl. RIGHT (FIELD CQNVERTED I The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at **`.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 Page 9 of 11 Certified Drawing For 1.5T SS HP-SEER2; Project: Sunrise Edmonds-1.5T SS HP 05/15/2023 Pre ared B UNIT CONNECTION SIZES SUCTION; 018 S 02/ - 5!8' I.O. SWEAT 030 6 03fi - 3/•' I.D. SWEAT OA2 THRU 060 - 7/8" I.O. $WEFT LIQUID: 3/8' L D. SWEAT CONDENSATE: 3/a' FP7 8 15/t6" � � I SCONNECT OR CIRCUIT DREAMER • LOCATION LOWER, CONTROL, i ELECTRIC HEATER ACCESS PANEL PANELACCESS 2 5l8' I TTING IOU IO LINE CONNECTION PANEL SUCTION LINE CONNECTION 0 � 10 �`� g fi 3l16" 5'--I CFI LTER ACt ESS OPENING PANEL +' D INLET AIR FRONT VIEW SHOWN WITH "A' COIL DETAILS CONNECTION LoCATIONS FOR uPFLOw oR HORIi. APPLIcaiT�:•.s Indoor Coil NOTE: 1. SERIES DESIGNATION IS THE 1�7H POSITION OF UNIT PRODVLT NUMBER 2. ALL DIMENSIONS ANE IN "INC NES' UNLESS NOTED. 7 /8'. 1 JJ32' 2 1/8" 2' DIA. N.O. 'S FOR NIGH VOLTAGE POWER WIRING TJD"DIA. N.O. 1 7J8" FOR LOW VOLTAGE [ONTaOL wIRING ALTERNATE 7!8•DIA. N.O. 1 15/t6' 1' FOR LOW VOLTAGE 1 3l8' CONTROL WIPING TOP VIEW INLET AIR A Unit Model: FJ4D Unit Size: 18,000 Btuh (Size 18) Voltage: 208-1-60 V-Ph-Hz Cabinet Insulation: TXV/ 14 Inches Cabinet PartNumber: FJ4DNXA18L00 SLOPE COIL DETAILS CONNECTION LOCATIONS SHONN FON UPFLOW ON HONII. LEFT APPLICATIONS ACCESS PANEL CONFIG. FOR SLOPE COILS DOWNFLOW OR HORIZ. RIGHT APPLICATIONS ARD "A" COILS DOWNFLOW APPLICATIONS i�it INNiHAY NOTE: ALLOW Zt' FROM FROkT FOR SERVICE 22 t/16' D 3rt6" 11' 7/8' 1' OUTLE7 AIR r 3J�" �--ALTERNATE 7/8',1 3132".2'DIA. N.O. 'S NOTE: NODULAR FOR HIGH VOLTAGE UNITS WILL HAVE POKER wIRING A TWO-PIECE OPPOSITE SIDE CABINET OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING f SLOPE COIL UNITS ONLt7 t 1J2' - � - l I• � I � H I NAY F0a 19' I NODJLZR UNITS L - - - - - � OPENING 19 13/16" 2 1J2' RIGHT SIDE VIEW INLET AIR Dimensions and Weights Indoor Coil Hei ht 42.69 in Width 14.31 in Len th 22.06 in Shipping Weight 120. Ib Dimensions A B C D E F G H J 42.69 in 14.31 in 12.44 in 12.31 in 10.44 in 18.13 in 18.63 in -- 12.00 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the Ieltest product literature and the AHRI directory at ***.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 Page 8 of 11 25SCA5 �Camfort-'�' Series Single -Stage Air Conditioner i - with Fulron�F Refrigerant -112 Tea 5 Tons Turn to the experts Product Data �����9I1��1� 1 s r �, ' ,� i�� �� �� ll''I jjII -IIyI '�,I,I.,I,�l9RI1I��I�1��� �tl�li[i�lll4ji ��:i14F�1�1�1� II I���� 111 � �I anti ���llf �{� I' Illilja�ll lillllll�'N y � R!I '1�19�lUlllll� �, �1��11i��llll +I���u Thus trait has been designed ntili2ing Courier's non-02�ane depleting Ptaan$ refrigerant Heat pumps tNith ptttalt� refrigerant prostide a cal6ectitm of featares unmatched try any other family of egaipment. N(3T'F: Ratings cantaiaed is this dact>ment are subject to change at an}' time. Always refer to the AHRI directory {wu'tAr.aluidirectotp-orgj for the mast up-ur�a:e ratings inbo�atiaa Industry leading Features r Benefits Efficiency • 14.3 - l5 � SEER: r 11.0 - 12.i EIS i 7.5 - 8.1 HSPF: (depending oa unit sine and unda'ot< cambiaatilon insotilled) • l4fi�atabe technology refrigeration sgstE� • Indoor air quality accessories ai'ailable Sound • Sound let: e]s as Eow as 89 dBA tRrith accessaDy sound blanket Cam>iort • System suppolts praTT�+,,,TONble ar s+.audard thermostat controls Reliability • Nan-0xaae depleting Pltrolt� refrigerant • Saoll compressor • Internal pressure relief t-a}se • lntetnal the."mal ot-erlaad • Loss afchaTge snitch • Fi7ter driier • Balanced refrigeration s}stem for z�sl T�s;Iaum relic-bility Durability �Ieatherrlimor*" Protection Pad6age: • Solid. datable sheet metal coasavcttoa • Dense n�i:te coil guard Applications ' Lang -line - trp to 2 `;9 feet (76.2Ci m) tote[ equis'alent Length. ap to 2D(t beet (50.4b m) condenser abase e�paratar, ar t� to t[4 ft- (I!�.38 mJ esaporatar ebrYlae condenser (See Lrnt�A Guide fur male itlformatiaa) • Lear ambient coaling (dawn to 4°F.�-17.8°Cj with approved [ow ambient accessory kiG Residential Carrier Products Bldr 1.37 Page 10 of 11 UNIT DATA vUE3JEtiTTO CHANGE WITHOUT NOTICE o � F w � � L � � � m J C!D � � N F � Q Z � C � O � � � ('� N � C Z � � � O L w Q oO U � w � ILI F N � J � Cn C Z i p� W � LJJ LL 3 �~ O m a� (] O � O v- NER Ti��M-� 7 [1� � Wn� •9� � A •.,�QFC45976 F,O •.•' � �� p �Pp ... ISTER,.. �. p ��Opss�ONAL ENGp �� 23 ooa❑aoo � - `� ExPIREs: 10/25/24 STAFJDARD FEATURES - •Multi -tap ECM (electronic commutating motor) motors -all sizes • Integrated mo#ar controls, with 90-sec off TDf� function, ,� have replaced integrated circuit board • Five available speed tags to meet a wide range of appiicatians • Large, grooved tube, louvered fin coils O • Efficient, quiet, time -tested bk�urer housings and diffusers � ^ � • Sturdy, drairrable condensate pans 1� `OV �. Cabirtet construction features innovations designed to prevent r T 1 �I canine# sweating W � M • Tested for condensate disposal in much t�Dugher conditions than W Air Conditioning and Refrigeration Institute requirements ■ Super -thick R-4.2 insulation with vapor balmier • Pre -painted gahranilzed steel cabinet (taupe metallic) • • Cabinet air leakage of less than 2% at 4-Si in.W .C. and cabinet air O leakage less than 1.496 at 0.5 in_ W.C.. whlen Tested in accordance wikh ASFii�AE 193 standard_ • Installation -flexible, multipoise units � T 1 j(�lj • Horizontal hanging provisions on cabinet W � • No tools required to access fitter ' = .tom-� • tJewly improved fitter rack area filter door insulation W W V 1 `� t�,,,,�N,,,yo,,,r,�, added for improved air seal r vul O ��'�'�1 itt MMI I�aN+� ■ lL�' 11 ,,,,,�,16r„ Factory-instaEled heater packages available on selec# `„ �,,,,,P, models (5- throng h f 5 kSM1F) � 1 dsWLL,tr IKMsaE . � through 3E)-kW accessory heaters -field installed v ��t�. �r��Ny - • Factory -supplied power plug � T 1 ^ O ■ Easy plug-in provisions for heater installation � H - •Entry options for high and low voltage wiring hook-up �T� J • Leak -Preventing sweat connections O N••j ``� `"-' C �L U� •Thermostatic expansion valve, T?CV, an Gill sizes .ju�dir. _ % O • Designed for manufactured housing applications r1w/, 1 ^ r„�,� _ - LIMITED WA'RRANTy'� � � V , �T� ' � Armor�'��h 10 year parts to original pt,rchaser upon timely registration, � !�I otherwise 5 years ' Far te64de!Itlal a�pftcaP.ktns. see urarrdrrty tar fir! details. ISSUE TLYS tlocumert~ Saes not txaTtaln techt4ca! data eanVdletl b71 ttHe E+tR Ix ITAR. Residential Carrier Products Bldr 1.37 Page 11 of 11 RECEIVED Jul 12 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT M 0.3 EQUIPMENT DATA SHEETS PROJECT NO. Q2Q_Q%g COPIRIGHT 2023 PINEHURST ENGINEERING, PLLC 0 4' 8' 16' `IIT✓ I SCALE: 1/8" = 1'-0" 7/4/23 COPIRIGHT 2023 PINEHURST ENGINEERING, PLLC TN�ROOF PLAN -MECHANICAL SCALE: 1/8" = 1'-0° GENERAL NOTES 1. DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW SPLIT SYSTEM UNITS ARE REPLACING THE SAME TYPE AND CAPACITY SPLIT SYSTEM IN THE SAME LOCATION, UTILIZING EXISTING DUCTWORK AND POWER SUPPLY. PLAN NOTES 01 STAGING OF EQUIPMENT AND CRANE LOCATIONS TO BE COORDINATED AND APPROVED PRIOR TO CONSTRUCTION. O2 NEW UNIT SHALL BE INSTALLED IN SAME LOCATION AS EXISTING O3 EXISTING ROOFTOP HVAC EQUIPMENT NOT IN SCOPE OF WORK (EXISTING TO REMAIN). ® NEW OHP-202 REPLACEMENT 1.5-TON UNIT IS THE SAME TYPE, WEIGHT AND OUTPUT CAPACITY AS EXISTING. NO NEW ROOF PENETRATIONS ARE REQUIRED FOR THIS WORK. RE -USE THE EXISTING ELECTRICAL DISCONNECT SWITCH AS APPLICABLE. RE -USE EXISTING CONTROL WIRING. 0 4' 8' 16' �� SCALE: 1/8" = 1'-0" 7/4/23 m CV 0 0 U w z w _U J � 23 N O 00 3 Q z 0 Q w D �L ��g