Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD2021-1415+Mechanical_Plan+11.5.2021_1.58.20_PM+2505590
d X GENERAL ABBREVIATIONS ADDN ADDITION, ADDITIONAL MAX MAXIMUM AFF ABOVE FINISHED FLOOR MBH THOUSAND BRITISH THERMAL UNITS PER APPROX APPROXIMATELY HOUR ARCH ARCHITECT MECH MECHANICAL; MECHANICAL CONTRACTOR AUX AUXILIARY MFR MANUFACTURER BLDG BUILDING MIN MINIMUM; MINUTE BTU BRITISH THERMAL UNIT MISC MISCELLANEOUS BTUH BRITISH THERMAL UNITS PER HOUR N NORTH COND CONDENSATE NA NOT APPLICABLE NC NORMALLY CLOSED CONN CONNECT; CONNECTION NO NORMALLY OPEN; NUMBER CONST CONSTRUCTION NITS NOT TO SCALE CONT CONTINUOUS; CONTINUATION COORD COORDINATE OC ON CENTER OD OUTSIDE DIAMETER; OVERALL DIMENSION DEG DEGREE CIA DIAMETER PD PRESSURE DROP DIM DIMENSION PH PHASE DISCH DISCHARGE POC POINT OF CONNECTION DN DOWN PRELIM PRELIMINARY DR DRAIN PS PRESSURE SWITCH DWG DRAWING PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAGE EA EACH PT PRESSURE/TEMPERATURE TAP EFF EFFICIENCY ELEV ELEVATION; ELEVATOR QTY QUANTITY ENT ENTERING EQ EQUAL REF REFERENCE EQUIP EQUIPMENT REQD REQUIRED EX, (E) EXISTING RET RETURN EXP EXPOSED RM ROOM EXPL EXPLOSION RPM REVOLUTIONS PER MINUTE F FAHRENHEIT S SOUTH FLEX FLEXIBLE SCHED SCHEDULE FLR FLOOR SECT SECTION FP FIRE PROTECTION; FREEZE PROTECTDN SQUARE FEET FT FEET; FOOT; FEET OF WATER(PRESS$HT SHEET SOL SOLENOID GA GAGE; GAUGE SPEC SPECIFICATION GAL GALLON SPECD SPECIFIED GC GENERAL CONTRACTOR SO SQUARE GEN GENERAL STD STANDARD GPM GALLONS PER MINUTE STRUCT STRUCTURAL ENGINEER H HEIGHT; HIGH HP HORSE POWER TD TEMPERATURE DIFFERENTIAL HR HOUR TEMP TEMPERATURE HZ HERTZ THRU THROUGH TYP TYPICAL IBC INTERNATIONAL BUILDING CODE IFC INTERNATIONAL FIRE CODE UTIL UTILITY IMC INTERNATIONAL MECHANICAL CODE IN INCH V VOLT INSUL INSULATE; INSULATION VAR VARIABLE VEL VELOCITY KW KILOWATT VERT VERTICAL KWH KILOWATT HOUR VOL VOLUME L LENGTH; LONG (DIM) W WATER; WIDE(DIM); WATT LB POUND W/ WITH LBS/HR POUNDS PER HOUR W/O WITHOUT LF LINEAL FEET WT WEIGHT LO LOW LTG LIGHTING YD YARD YR YEAR ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE DMPR DAMPER DB DRY BULB TEMPERATURE(°F) EA EXHAUSTAIR EAT ENTERING AIR TEMPERATURE EF EXHAUST FAN EG EXHAUST GRILLE EXH EXHAUST FA FACE AREA FC FAN COIL; FORWARD CURVED FCU FAN COIL UNIT FF FINAL FILTER FPM FEET PER MINUTE FV FACE VELOCITY GALV GALVANIZED GR GRILLE HC HEATING COIL HTG HEATING HV HEAT AND VENT UNIT HHWR HEATING WATER RETURN HHWS HEATING WATER SUPPLY IMC INTERNATIONAL MECHANICAL CODE LAT LEAVING AIR TEMPERATURE MA MIXED AIR NPSH NET POSITIVE SUCTION HEAD CA OUTSIDE AIR OAT OUTSIDE AIR TEMPERATURE OBD OPPOSED BLADE DAMPER ODP OPEN DRIPPROOF OSA OUTSIDE AIR PLC PROGRAMMABLE LOGIC CONTROLLER RA RETURN AIR RG RETURN GRILLE S SUPPLY SP STATIC PRESSURE SA SUPPLY AIR; SOUND ATTENUATOR SF SUPPLY FAN SG SUPPLY GRILLE SR SUPPLY REGISTER T,TSTAT THERMOSTAT UH UNIT HEATER UV UNIT VENTILATOR VAV VARIABLE AIR VOLUME VSD VARIABLE SPEED DRIVE VENT VENTILATE; VENTILATION VD VOLUME DAMPER WG WALL GRILLE; WATER GAGE WSEC WASHINGTON STATE ENERGY CODE WB WET BULB TEMPERATURE(°F) HVAC ABBREVIATIONS AL ACOUSTIC LINED; ALUMINUM AC AIR CONDITIONING AD AUTOMATIC DAMPER AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER BHP BRAKE HORSEPOWER C CONDENSATE; COMMON CFM CUBIC FEET PER MINUTE CG CEILING GRILLE COND CONDENSATE CV CONSTANT VOLUME GENERAL LEGEND GENERAL CONSTRUCTION NOTES NORTH NORTH ARROW 1. PLANS ARE DIAGRAMMATIC AND DO NOT SHOW ALL BRANCHES, VALVES, SPECIALTIES AND EQUIPMENT. 2. ALL PIPING, VALVES AND EQUIPMENT ARE TO BE REMOVED IN DEMOLITION AREAS. 7 DETAIL/DRAWING REFERENCE 3. VALVES INDICATED FOR SHUT-OFF ISOLATION ARE SHOWN IN APPROXIMATE H-o LOCATIONS. REFER TO REFERENCED BLDG. DRAWINGS FOR DETAILED SYSTEMS. 4. FIELD VERIFY EXACT LOCATIONS VALVES, EQUIPMENT AND PIPING. 5. CONTRACTOR TO VERIFY SYSTEM SHUT DOWN PRIOR TO ANY REMOVAL WORK. 6. CONTRACTOR TO RE -OPEN VALVES AFTER COMPLETION OF REMOVAL, CAP, & CUT H-0 SECTION REFERENCE TO RESTORE SYSTEM OPERATION WHERE REQUIRED. 7. SYSTEM SHUT DOWN REMOVAL, CUT & CAP SHALL ONLY BEGIN AFTER NEW, RE-ROUTED SYSTEM IS IN PLACE FOR SERVICE CONTINUITY WHERE REQUIRED. O CONSTRUCTION NOTE 8. ALL SYSTEMS SHALL BE DRAINED AND DISPOSAL OF FLUIDS HANDLED AS REQUIRED PER OWNER'S STANDARDS. Al REVISION SYMBOL 9. MECHANICAL DRAWINGS SHOW DISCONNECT AND RECONNECT POINTS AT THE PROJECT'S BOUNDARIES. AN ATTEMPT WAS MADE TO SHOW MAJOR MECHANICAL UTILITY WORK WITHIN THE PROJECTS BOUNDARIES. THE CONTRACTOR IS POINT OF CONNECTION RESPONSIBLE FOR REMOVAL/DISPOSAL OF ALL MECHANICAL WORK WITHIN THE PROJECTS BOUNDARY. BOLD LINE WEIGHT INDICATES NEW WORK 10. DO NOT PENETRATE STRUCTURAL STEEL TO ROUTE SHOWN PIPING AND DUCTWORK. LIGHT LINE WEIGHT INDICATES EXISTING WORK 17e7SLASHED LINE INDICATES EXISTING WORK TO BE DEMOLISHED HVAC DUCTWORK LEGEND SINGLE LINE DUCTWORK INDICATES VIEW DIMENSION LESS THAN 12 INCHES SUPPLY OR EXHAUST TAKEOFF �® SUPPLY DUCT TURNING TOWARD �© SUPPLY DUCT TURNING AWAY }� EXHAUST DUCT TURNING TOWARD --�� EXHAUST DUCT TURNING AWAY +� ROUND DUCT TURNING TOWARD n ROUND DUCT TURNING AWAY TRANSITION MID MID MOTORIZED DAMPER VOLUME DAMPER FBBD �BBD BACKDRAFT DAMPER FD D �j S_ FIRE DAMPER —1--i E_11I1 FLEXIBLE CONNECTION TVT Ili TURNING VANES APPROVED SUPPLY DIFFUSER RETURN GRILLE EXHAUST GRILLE TEMPERATURE SENSOR / THERMOSTAT EQUIPMENT TAG PLANS MUST BE ON JOB SITE WASHINGTON ENERGY CODE NOTES 1. BALANCE ALL HVAC SYSTEMS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE 2018 EDITION, GENERALLY ACCEPTED ENGINEERING STANDARDS AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE SPECIFICATION SECTION 23 05 93 AND ALL OTHER APPLICABLE SPECIFICATION SECTIONS. 2. ALL DUCTWORK SHALL BE CONSTRUCTED AND SEALED PER 2018 IMC AND 2018 WSEC SECTION C403.10.2. 4. ALL DUCTWORK IS LOW PRESSURE DUCTWORK. 5. EACH SUPPLY AIR AND EXHAUST OUTLET SHALL BE EQUIPPED WITH MEANS FOR AIR BALANCING IN ACCORDANCE WITH THE REQUIREMENTS OF CHAPTER 6 OF THE 2015 IMC (SECTION C408.2.2.1 OF 2018 WSEC) DRAWING INDEX H-0 HVAC LEGEND, ABBREVIATIONS, AND GENERAL NOTES HD-1 SOLIDS PROCESSING BUILDING DEWATERING FLOOR HVAC DEMOLITION PLAN HD-2 SOLIDS PROCESSING BUILDING SHOP FLOOR HVAC DEMOLITION PLAN H-1 SOLIDS PROCESSING BUILDING BASEMENT HVAC PLAN H-2 SOLIDS PROCESSING BUILDING DEWATERING FLOOR HVAC PLAN H-3 SOLIDS PROCESSING BUILDING SHOP FLOOR HVAC PLAN H-4 SOLIDS PROCESSING BUILDING ROOF HVAC PLAN H-5 STANDARD SEQUENCE OF OPERATIONS, AND POINTS LIST H-6 HVAC SECTIONS H-7 HVAC SCHEDULES P-0 PLUMBING LEGEND, ABBREVIATIONS, AND GENERAL NOTES PD-1 SOLIDS PROCESSING BUILDING DEWATERING FLOOR PLUMBING DEMOLITION PLAN PD-2 HEADWORKS AREA PLUMBING DEMOLITION PLAN P-1 SOLIDS PROCESSING BUILDING BASEMENT PLUMBING PLAN P-2 SOLIDS PROCESSING BUILDING DEWATERING FLOOR PLUMBING PLAN P-3 SOLIDS PROCESSING BUILDING SHOP FLOOR PLUMBING PLAN P-4 ODOR CONTROL SYSTEM AREA PLUMBING PLAN P-5 HEADWORKS AREA PLUMBING PLAN P-6 PLUMBING DETAILS P-7 PLUMBING SCHEDULE F-0 FIRE PROTECTION LEGEND, ABBREVIATIONS, AND GENERAL NOTES F-1 SOLIDS PROCESSING BUILDING DEWATERING FLOOR FIRE PROTECTION PLAN F-2 SOLIDS PROCESSING BUILDING SHOP FLOOR FIRE PROTECTION PLAN F-3 FIRE PROTECTION DETAILS City Of Edmonds Building Department ---------------------------------- Work : MECHANICAL --------------- ------------------------------------- Address 200 2ND AVE S Owner r - - - - - WASTE WATER TREATMET PLANT Approved Date'--11%1612021 ------------------ ; Building Official:, Eri* C witr PermitNDmber BLD2021-1415 -------------------------- NEW PLAN SET WITH ONLY MECHANICAL RECEIVED Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Call 48 Hours Before You Dig i-600-424-5555 UNDERGROUND SERVICE bh(AMERESCO CONSULTANT BHC Consultants, LLC zossos.3400 1601 Fifth Avenue, Suite 500 206S05.3406(faz) Seattle, Washington 98101 ww.bhcconsultants.com fS l ENGINEERS Seattle//$ nkane//Beltimr+re P Designed: S. Boucher Scale: ans^=t'-o° Green . Clean . Sustainable Q EDMONDS WWTP CARBON RECOVERY HVAC LEGEND, ABBREVIATIONS, AND GENERAL NOTES Drawing: H-0 Drawn: B. Boone sheet: 76 of 114 One Inch At Full Scale — File: P20-10570_H-0 ISSUED FOR CONSTRUCTION 10-2021 SJB KMC Checked: K. Chadwick If Not One Inch Scale Accordingly Date: October 2021 No. Revision Date B A 'd m LL 5 v a x z- 0 2 SOLIDS PROCESSING BUILDING DEWATERING FLOOR HVAC DEMOLITION 0 4 e 12 PLAN ,..7...,,,', Scale: 3/16"=1-0" SCALE .3/16"=1'-O" HD-1 NOTES 1. ONLY EXISTING DUCTWORK, PIPING EQUIPMENT RELEVANT TO THE PROJECT ARE SHOWN. ALL OTHERS TO REMAIN AS -IS. REMOVAL NOTES O REMOVE EXISTING FAN AND FIRE DAMPER. PATCH WALL. PATCH WALL PENETRATION PER STRUCTURAL. O2 REMOVE DUCTWORK AND DIFFUSERS IN HATCHED AREA. RECEIVED Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Call 48 Hours Before You Dig 1-800-424-5555 UNDERGROUND SERVICE bh(A.F Designed: s.Boucher g Scale: EDMONDS WWTP CARBON RECOVERY Drawing: HD-7 101k, fS l AMERESCO SOLIDS PROCESSING BUILDING sheet: 77 of 114 CONSULTANTS BHC Consultants, LLC 206.505.3400 1601 Fiflh Avenue, Suite 500 206.505.3406 (faz) Seattle, Washington ee101 ww.bncconsultants.com ENGINEERS Seattle nkane//Beltimr+re P Drawn: B. Boone one Inch At FUII Scale — Green . Clean . Sustainable DEWATERING FLOOR HVAC DEMOLITION PLAN File: P18-10570_HD-3 Checked: K. Chadwick ISSUED FOR CONSTRUCTION 10-2021 SJB KMC If Not One Inch Scale Accordingly Date: October 2021 No. Revision Date B A 'd m �E m LL 5 v a x NOTES 1. ONLY EXISTING DUCTWORK, PIPING EQUIPMENT RELEVANT TO THE PROJECT ARE SHOWN. ALL OTHERS — — — — TO REMAIN AS -IS. REMOVAL NOTES O----- O1 REMOVE PLENUM AND DUCT WORK IN HATCHED AREA. PATCH ROOF PENETRATION PER ARCHITECT. ILO REMOVE FAN AND DUCT WORK IN HATCHED AREA, REMOVE VERTICAL DUCT SECTION TO EXISTING GROUND FLOOR WALKWAY. MCC / MCC ELECTRICAL CHEMICAL CHEMICAL O REMOVE EXISTING 10 KW ELECTRIC UNIT 3 MECHANICAL — FEED STORAGE HEATER AND ASSOCIATED THERMOSTAT. O EXISTING LOUVER AND INSECT SCREEN TO REMAIN IN PLACE. REMOVE EXISTING CONTROL DAMPERS AND ASSOCIATED ACTUATORS. O5 REMOVE ALL PIPING, EQUIPMENT, DUCTWORK, FLUES, AND APPURTENANCES ASSOCIATED WITH THE INCINERATOR BACK TO MAIN OR LAST ACTIVE BRANCH. CAP AT MAIN OR LAST ACTIVE BRANCH. 4 i O REMOVE EXISTING MOTORIZED DAMPER, ACTUATOR, AND ASSOCIATED WIRING. SOLIDS PROCESS c c DUCT/OPENING TO REMAIN AS -IS. ' BUILDING O7 REMOVE GRILLE, DUCTWORK AND MOTORIZED DAMPER IN HATCHED AREA. SAVE FOR REUSE. Li 8 REMOVE INLET GRILLE AND DUCTWORK IN L HATCHED AREA. PATCH WALL PENETRATION EXISTING FUME PER STRUCTURAL. HOOD TO REMAIN O9 REMOVE DUCTWORK IN HATCHED AREA. PATCH WALL PENETRATION PER INCINERATOR STRUCTURAL. ROOM SHOP 10 COORDINATE DOWN TIME FOR WELDING HOOD WITH OWNER AT LEAST 7 DAYS IN ADVANCE. WELDING HOOD SHALL BE IC-662 OPERATIONAL AND SHALL EXHAUST OUTSIDE DURING CONSTRUCTION. EXISTING 28x28 DN EXISTING 34x34 EXISTING 10'x3'x6'H CF-640 EXISTI 42x42 CF-641 SOLIDS PROCESSING BUILDING SHOP FLOOR HVAC DEMOLITION PLAN rf� SCALE: 3/16" = 1'-0" HD-2 ASH DETWATERING 3 r1 MAINTENANCE / OFFICE 0 4 6 12 Scale: 3116"= 1'-0" STORAGE RECEIVED Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Call 48 Hours Before You Dig 1-800-424-5555 UNDERGROUND SERVICE bh(A.F 101k, CONSULTANTS BHC Consultants, LLC zossos.3400 1601 Fifth Avenue, Suite 500 206S05.3406(faz) Seattle, Washington 98101 ww.bheconsultants.com fS l ENGINEERS Seattle Spokane //Baltimore P Designed: S. Boucher g Scale: 3/i6"-1'-0" AMERESCO Green . Clean . Sustainable EDMONDS WWTP CARBON RECOVERY SOLIDS PROCESSING BUILDING SHOP FLOOR HVAC DEMOLITION PLAN Drawing: HD-2 Drawn: B. Boone sheet: 78 01 114 one Inch At FUII Scale - File: P18-10570_HD-4 ISSUED FOR CONSTRUCTION 10-2021 SJB KMC Checked: K. Chadwick If Not One Inch Scale Accordingly Date: October 2021 No. Revision Date B A 'd �E m LL 5 v a x 10x1 SD-1 300 CFM 8' A.F.F TYP. 10 10x16 10x20 UP 12x8, UP TYP. 10 - V � v ■.-- leiIN 1 , Lupo LE �illlunllnnlii:�Pil�� _ ;III .'�_ CONSTRUCTION NOTES O1 INSTALL DUCTWORK 10' ABOVE FINISHED FLOOR. O INSTALL CLASS 2 DIV 2 RATED TEMPERATURE SENSOR 5A.F.F. Call 48 Hours Before You Dig 1-800-424-5555 UNDERGROUND SERVICE RECEIVED y SOLIDS PROCESSING BUILDING BASEMENT HVAC 0 4 8 Nov 05 2021 p PLAN Scale: 114-1-0• CITY OFEDMONDS DEVELOPMENT SERVICES PFC/STEREp �2 SCALE 1/4" - V-o° H-1 DEPARTMENT Fs �, S/ONAL EN 10.18.2021 SICNeD bhcolf Designed: S. Boucher g Scale: EDMONDS WWTP CARBON RECOVERY Drawing: H-7 �l A M E R E S C O SOLIDS PROCESSING BUILDING sheet: 79 of 114 CONSULTANTS Drawn: B. Boone One Inch At FUII Scale BASEMENT BHC Consultants, LLC zossos.3400 ENGINEERS - File: P20-10570_H-1 ISSUED FOR CONSTRUCTION 10-2021 SJB KMC 1601 Fifth Avenue. Suite 500 206.505.3406 (faz) Seattle, Washington salol Seattle // Spokane // Baltimore P Checked: K. Chadwick If Not One Inch Scale Accordingly Green . Clean . Sustainable H VAC PLAN Date: October 2021 No. Revision Date B A 'd —.l,hcconsultants.com CONSTRUCTION NOTES m LL 5 v li x I SOLIDS PROCESSING BUILDING 0 4 8 12 DEWATERING FLOOR HVAC PLAN / 7VA\ Scale: 3/fs"=r-0" SCALE: 3/16" = 1'-0" / H--2 1 O1 INSULATE HEAT EXCHANGER AND ASSOCIATED U-SHAPED DUCT WITH 3" OF FIBERGLASS BAT WITH ALUMINUM JACKET. CONTRACTOR TO COORDINATE WITH ECOREMEDY BEFORE INSTALLING INSULATION. O INSULATE SCRUBBER WITH 3" OF FIBERGLASS BAT WITH ALUMINUM JACKET. CONTRACTOR TO COORDINATE WITH ECOREMEDY BEFORE INSTALLING INSULATION. O INSULATE CYCLONE AND PRODUCT COLLECTOR WITH 3" OF FIBERGLASS BAT WITH ALUMINUM JACKET. CONTRACTOR TO COORDINATE WITH ECOREMEDY BEFORE INSTALLING INSULATION. O4 INSTALL DUCTWORK AS HIGH AS POSSIBLE AGAINST SLAB. O INSTALL BOTTOM OF DUCT 18'-6" ABOVE FINISHED FLOOR. O INSTALL BACKDRAFT DAMPER. GREENECK MODEL WD-400 OR EQUAL. RECEIVED Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Call 48 Hours Before You Dig 1-800-424-5555 UNDERGROUND SERVICE bh(A.Fff1k CONSULTANTS BHC Consultants, LLC zossos.3400 1601 Fifth Avenue, Suite 500 206S05.3406 (faz) Seattle, Washington 98101 ww.bheconsultants.com fS l ENGINEERS Seattle // Spokane // Baltimore P Designed: S. Boucher g Scale: AMERESCO Green . Clean . Sustain a b I e EDMONDS WWTP CARBON RECOVERY SOLIDS PROCESSING BUILDING DEWATERING FLOOR H VAC PLAN Drawing: H-2 Drawn: B. Boone Sheet: 80 of 114 One Inch At Full Scale — File: P20-10570_H-2 ISSUED FOR CONSTRUCTION 10-2021 SJB KMC Checked: K. Chadwick If Not One Inch Scale AccordinglyDate: October 2021 No. Revision Date B A 'd a x SUPPLY, DN 40x40 EXHAUST, DN EF 3 BDD FAN TG-1 1,250 CFM UP I� 22"0 0 • Ill PLC IGYM SHOP \ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — L IC-662 �� 12x12 UP I I I I I I I I I I I I I I I I I I I � —III------- � III —III--------- CHEMICAL CONSTRUCTION NOTES 1O CONNECT DUCTWORK TO EXISTING, ROUTE DUCT TO ROOF HOOD. O INSTALL 14X14 GRAVITY BACKDRAFT DAMPER GREENHECK MODEL WD-100 OR EQUAL. O REINSTALL EXISTING DUCTWORK, GRILLE, AND MOTORIZED DAMPER. RELOCATE DUCT SUPPORTS AS NECESSARY. 4O INSTALL 30x24 LOUVER WITH GRAVITY BACKDRAFT DAMPER AND INSECT SCREEN IN EXISTING OPENING. LOUVER TO BE GREENHECK MODEL ESD435 OR EQUAL. BACKDRAFT DAMPER TO BE GREENHECK MODEL WD-400 OR EQUAL. FILL THE REST OF THE EXISTING 42" ROUND OPENING WITH SHEET METAL ON BOTH SIDES OF THE WALL. O INFILL EXISTING 42"0 OPENING. SEE STRUCTURAL DRAWINGS FOR DETAILS. O INSTALL CLASS 2 DIV 2 RATED TEMPERATURE SENSOR 5' AFF. OINSTALL 24x24 RELIEF BACKDRAFT DAMPER GREENHECK MODEL BR-30 OR EQUAL. O INSTALL VFD 5' AFF. Call 48 Hours Before You Dig 1-800-424-5555 UNDERGROUND SERVICE 2F RECEIVED Cy M. SOLIDS PROCESSING BUILDING ��p�� wAsy� SHOP FLOOR HVAC 0 4 a 12 Nov 05 2021 PLAN Scale: 3/16"=1'-0" CITY OF EDMONDS DEVELOPMENT SERVICES PF121 �2 O/S SCALE: ins" = T-O" H-3 DEPARTMENT Fs s/ONAL EN 10.18.2021 SI0N8D bhrA; CONSULTANTS BHC Consultants, LLC 206.505.3400 1601 Fifth Avenue, Suite 500 206S05.3406 (faz) Seattia, Washington saiol ww.bncconsultants.com fsi ENGINEERS $eatlle // S nkane Baltimore P Designed: S. Boucher g Scale: 3116"=1'-0" AMERESCO Green • Clean • Sustainable EDMONDS WWTP CARBON RECOVERY SOLIDS PROCESSING BUILDING SHOP FLOOR H VAC PLAN Drawing: H-3 Drawn: B. Boone sheet 81 of 114 One Inch At Full Scale — File: P20-10570_H-3 ISSUED FOR CONSTRUCTION 10-2021 SJB KMC Checked: K. Chadwick H Not one Inch Scale Accor4ingly Date: October 2021 No. Revision Date B A 'd m m LL 5 v a x EX 4'-0"x4'-0" SKYLIGHT (TYP) z z z EX 4'-0" X 16'-0" EXHAUST PLENUM WITH 2" ALUMINUM GRATING EX STACK EX 3'-0"x6'-0" SKYLIGHT (TYP) z \ RH 2 _/ x z EX 5-0"xF-0" SKYLIGHT RH 1 / z z z 3H INFILLED 3'X10' EXHAUST z z PLENUM ROOF HOOD, SEE ARCHITECTURAL DRAWINGS, TYP. IS SOLIDS PROCESSING BUILDING ROOF HVAC PLAN SCALE: 3/16" = 1'-0" H-4 0 4 6 12 Scale: 3116"= 1'-0" RECEIVED Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Call 48 Hours Before You Dig 1-800-424-5555 UNDERGROUND SERVICE bh(Aw Designed: S. Boucher g Scale: a/1s^=1'-0° EDMONDS WWTP CARBON RECOVERY Drawing: H-4 fSi AMERESCO(4 SOLIDS PROCESSING BUILDING sheet 82 01 114 CONSULTANTS BHC Consultants, LLC 206.505.340o 1601 Firth Avenue, Suite 500 206.505.3406 (fax) Seattle, Washington 98101 ww.bhcconsultants.com ENGINEERS Seattle // Spokane // Baltimore P Drawn: B. Boone one Inch At FUII Scale — c Not cOneco Inch Scale Accordingly Green • Clean • Sustainable ROOF HVAC PLAN File: P20-10570_H-4 Checked: K. Chadwick ISSUED FOR CONSTRUCTION 10-2021 SJB KMC Date: October 2021 No. Revision Date B A 'd SEQUENCE OF OPERATION m m 10 m IL 5 v a x 1. SOLIDS HANDLING ROOM THE PLC SYSTEM SHALL START/STOP THE SOLIDS HANDLING ROOM EXHAUST FAN EF-2 BASED UPON OCCUPANCY SCHEDULE. PROOF OF RUN STATUS SHALL BE MONITORED BY THE PLC SYSTEM WITH A CURRENT SENSOR. ANNUNCIATE ALARMS AT THE PLC FRONT END COMPUTER WHEN FAN FAILS TO START WHEN COMMANDED. 2. GASIFICATION ROOM GASIFICATION ROOM EXHAUST FAN EF-1 SHALL RUN CONTINUOUSLY AND WILL MODULATE BASED ON TEMPERATURE. TEMPERATURE SETPOINT SHALL BE 75F (ADJUSTABLE). PROOF OF RUN STATUS SHALL BE MONITORED BY THE PLC SYSTEM WITH A CURRENT SENSOR. SF-1 SHALL BE INTERLOCKED WITH EF-1 AND OPERATE CONTINUOUSLY AT CONSTANT VOLUME. PROOF OF RUN STATUS SHALL BE MONITORED BY THE PLC SYSTEM WITH A CURRENT SENSOR. ANNUNCIATE ALARMS AT THE PLC FRONT END COMPUTER WHEN FANS FAIL TO START WHEN COMMANDED OR WHEN ROOM TEMPERATURE REACHES 10°F ABOVE SET POINT. 3. ID FAN ROOM EF-3 SHALL START WHEN ROOM TEMPERATURE REACHES 90°F AND TURN OFF WHEN ROOM TEMPERATURE REACHES 70°F (ADJUSTABLE). PROOF OF RUN STATUS SHALL BE MONITORED BY THE PLC SYSTEM WITH A CURRENT SENSOR. ANNUNCIATE ALARMS AT THE PLC FRONT END COMPUTER WHEN FAN FAILS TO START WHEN COMMANDED OR WHEN ROOM TEMPERATURE REACHES 20oF ABOVE SET POINT. 4. FUME HOOD IN SHOP NEW EXHAUST MOTORIZED DAMPER SHALL BE OPEN WHEN FAN IS ON AND CLOSED WHEN FAN IS OFF. POINTS LIST: DESCRIPTION DI Al DO AO VP REMARKS EF-1 FAN ENABLE 1 FAN STATUS 1 CURRENT SENSOR FAN SPEED 1 ROOM AIR TEMPERATURE 1 SF-1 FAN ENABLE 1 FAN STATUS 1 CURRENT SENSOR EF-2 FAN ENABLE 1 FAN STATUS 1 CURRENT SENSOR EF-3 FAN ENABLE 1 FAN STATUS 1 CURRENT SENSOR ROOM AIR TEMPERATURE 1 SHOP FUME HOOD MOTORIZED DAMPER 1 EF 2 EG-1 1,430 CF TYP. 14 SD-1 300 CFM 8' A.F.F TYP. 10 F3H FZH SYSTEM DIAGRAM SCALE: NONE H-5 SLAB OPENING (STAIRS) EXISTING INTAKE LOUVER UP TO 17,000 CFM (NOT INCLUDING PROCESS) RECEIVED Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Call 48 Hours Before You Dig 1-800-424-5555 UNDERGROUND SERVICE bhCA. Irk CONSULTANS BHC Consultants, LLC 206.505.340o 1601 Fifth Avenue. Suite 500 206S05.3406 (faz) Seattle, Washington 98101 ww.bhcconsultants.com fS l ENGINEERS Seattle // Spokane // Baltimore P Designed: S.Boucher Scale: NONE AMERESCOSTANDARD On Green • C I ea n •Sustain a b I e EDMONDS WWTP CARBON RECOVERY SEQUENCE OF OPERATIONS , AND POINT LIST Drawing: H-5 Drawn: B.Boone Sheet: 83 of 114 One Inch At Full Scale — File: P20-10570_H-5 ISSUED FOR CONSTRUCTION 10-2021 SJB KMC Checked: K. Chadwick If Not one Inch Scale Accordingly Date: October 2021 No. Revision Date B A 'd oi E a x 22"(d EF 1 4" HOUSEKEEPING PAD 72X36 TO RH-3 SEE ARCH. DRAWINGS FOR DETAILS 72X36 TO RH-2 SEE ARCH. DRAWINGS FOR DETAILS 1Ff/i-Tl/-7 I I I I I I I n SECTION SCALE: 1/4" = 1'-0" H-3 46x38 EXHAUST 42x38 EXHAUST 22"0 40x40 EXHAUST BDD CONSTRUCTION NOTES O INSTALL GRAVITY BACKDRAFT DAMPER GREENHECK MODEL WD-410 OR EQUAL. O INSTALL BACKDRAFT DAMPER GREENHECK MODEL WD-100 OR EQUAL. RECEIVED Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Call 48 Hours Before You Dig 1-800-424-5555 UNDERGROUND SERVICE bh(A.FDesigned: CONSULTANTS Consultants, LLC zossos.3400 1601 Fifth Avenue. Suite 500 206S05.3406 (fax) Seattle, Washington e8101 ww.tneconsultantacom fS Ft NEERS $eatlle // S Spokane // Beltimr+re P S. Boucher Scale: NONE AMERESCOBHC Green • Clean • Sustainable EDMONDS WWTP CARBON RECOVERY HVAC SECTIONS Drawing: H-6 Drawn: B. Boone sheet: 84 of 114 One Inch At Full Scale — File: P20-10570_H-6 ISSUED FOR CONSTRUCTION 10-2021 SJB KMC Checked: K. Chadwick If Not One Inch Scale Accordingly Date: October 2021 No. Revision Date B A 'd FAN SCHEDULE CALLOUT FAN MAXINLET MAX OUTLET BASIS OF DESIGN E.S.P MOTOR ELECTRICAL SOUND SOUND OPERATING DRIVE (IN WC) LEVEL LEVEL WEIGHT TYPE MARK LOCATION FAN TYPE SERVICE CFM TYPE [11 RPM SPEED HP BHP V HZ 0 FEI [3] (DBA) (DBA) (LBS) MANUFACTURER MODEL NOTES EF 1 SOLIDS UTILITY SET GASIFICATION ROOM 20,000 BELT 1.00 773 1,725 10 8.32 460 60 3 1.19 76 79 1,321 GREENHECK USF-36 [2][4][5][6][71 HANDLING RM SF 1 SOLIDS MIXED FLOW GASIFICATION ROOM 3,000 BELT 0.65 1,490 1,725 1 0.77 460 60 3 1.48 61 64 227 GREENHECK QEI-15 [2][5][71 HANDLING RM EF 2 OUTDOORS UPBLAST SOLIDS HANDLING 250 BELT 0.25 805 1,725 1/4 0.04 115 60 1 N/A 45 - 119 GREENHECK CUBE-0994 [2][5][7][8][91 CENTRIFUGAL ROOM EF 3 OUTDOORS UPB LAST ID FAN ROOM 1,250 BELT 0.25 1,595 1,725 1/4 0.24 115 60 1 N/A 62 117 GREENHECK CUBE-100-4 [2][5][7][8][91 CENTRIFUGAL FUG SCHEDULE NOTES: [1] STATIC PRESSURE EXTERNAL TO FAN. [2] PROVIDE WITH EXPLOSION PROOF MOTOR [3] FEI: FAN EFFICIENCY INDEX [4] WHEEL TYPE: BI - ARRANGEMENT: 10 - CLASS: 0 - ROTATION: CW - DISCHARGE POSITION: UB [5] SPARK B CONSTRUCTION [6] PROVIDE WITH VFD EATON MODEL HMX01434NAB5M1 OR EQUAL [7] PROVIDE WITH INITIAL SET OF SHEAVES FOR FAN TO MEET CONDITIONS AS SCHEDULED. FOLLOWING INSTALLATION AND BALANCING, PROVIDE REPLACEMENT SET OF SHEAVES FOR FAN ACTUAL CONDITIONS, REGARDLESS OF WHETHER CONSTANT OR VARIABLE SPEED. [8] PROVIDE WITH CURB GREENHECK MODEL GPF [9] FAN TO BE CONFIGURED FOR WALL -MOUNTED APPLICATION ROOF HOOD SCHEDULE TYPE MARK AIR TERMINAL DESCRIPTION AIRFLOW (CFM) THROAT SIZE HOOD SIZE MRAA S DROP (IN. W.G.) MATERIAL BASIS OF DESIGN NOTES LENGTH WIDTH LENGTH WIDTH HEIGHT MANUFACTURER MODEL RH 1 ROOF HOOD 750 12" 12" 27" 26" 14" 0.084 GALVANIZED GREENHECK FGR [1][2][41 RH 2 ROOF HOOD 20000 72" 40" 96" 60" 23" 0.138 GALVANIZED GREENHECK FGR [3][5] RH 3 ROOF HOOD 3000 72" 40" 96" 60" 23" 0.008 GALVANIZED GREENHECK FGI [4][5] SCHEDULE NOTES: [1] PROVIDE WITH MOTORIZED DAMPER GREENHECK VCD-23 [2] PROVIDE WITH 12" ROOF CURB, GREENHECK MODEL GPI [3] PROVIDE WITH BIRD SCREEN [4] PROVIDE WITH INSECT SCREEN [5] PROVIDE WITH ROOF CURB ADAPTER / REDUCER GREENHECK MODEL ADP 46X78-36X72 UNIT HEATER SCHEDULE CALLOUT FAN HEATING CAPACITY ELECTRICAL OPERATING BASIS OF DESIGN MOTOR TYPE MARK LOCATION SERVICE CFM HP KW MODULATION V HZ 0 WEIGHT (LBS) MANUFACTURER MODEL NOTES UH 1 SOLIDS DISPOSAL SOLIDS DISPOSAL 850 1/2 10 SINGLE STAGE 480 60 3 148 MODINE HEX5-480360-10.0 [1][2] ROOM ROOM SCHEDULE NOTES: [1] UNIT RATED FOR CLASS 2 DIVISION 2 AREAS [2] PROVIDE WITH MOUNTING KIT, EXPLOSION PROOF MOTOR, AND WALL -MOUNTED EXPLOSION PROOF THERMOSTAT (RATED FOR CLASS 2 DIVISION 2, GROUP G, UL TEMPERATURE CODE T3) DIFFUSER, EXHAUST AND TRANSFER GRILL SCHEDULE CALLOUT AIR TERMINAL DESCRIPTION AIRFLOW CAPACITY LIMITS (CFM) NOMINAL SIZE NECK SIZE MAX NC MAX TSP DROP (IN. W.G.) MATERIAL OBD FINISH BASIS OF DESIGN NOTES MAXIMUM MINIMUM LENGTH WIDTH LENGTH WIDTH MANUFACTURER MODEL SD-1 DOUBLE DEFLECTION SUPPLY GRILLE 300 300 12" 8" 12" 8" 17 0.08 ALUMINUM YES #26 WHITE TITUS 30OFS EG-1 EXHAUST GRILLE 1430 1430 24" 12" 24" 12" 25 .10 ALUMINUM YES #26 WHITE TITUS 50F EG-2 EXHAUST GRILLE 1250 250 14" 14" 14" 14" 34 .15 ALUMINUM NO #26 WHITE TITUS 50F TG-1 TRANSFER GRILLE 1250 1250 30" 24" 30" 24" <10 0.01 ALUMINUM NO #26 WHITE TITUS 50F RECEIVED Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Call 48 Hours Before You Dig 1-800-424-5555 UNDERGROUND SERVICE Scale: Designed: S.Boucher NONE EDMONDS WWTP CARBON RECOVERY Drawing: H-7 bhrA.0 HVAC SCHEDULES Sheet: 85 of 114 CONSULTANTS f Y l Drawn: B. Boone One Inch At Full Scale AMERESCO(4 BHC Consultants, LLC 206.505.3400 E N G I N E E R S — File: P20-10570_H-7 ISSUED FOR CONSTRUCTION 10-2021 SJB KMC 1501 Fifth Avenue, Suite 500 zg6.5g5.34o6 (fax) Seattle // Spokane // Baltimore If Not One Inch Green . Clean . Sustainable No. Revision Date B A 'd Seattle, Washington 98101 www.bhcconsultants.com P Checked: K. Chadwick Scale Accordingly Date: October 2021