Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD2023-0591+MECH_Plan+5.15.2023_11.39.57_AM+3544665
GENERAL INFORMATION PROPERTY TAX NO.: 302404-9158 LEGAL DESCRIPTION: SEC 29 TWP 27 RGE 04BAAP 141FT S OF NW CDR SW1/4 TH E 150FT TH S SIFT TH E 80FT TH S 66FT TH W 230FT TH N 75FT TO TPB LESS ELY 71FT THOF & LESS W 30FT FOR RD TGW BEG NW CDR NW1/4 SW1/4 TH S141FT TH E 150FT TO TPB TH CONT E 7FT TH S 9FT TH W 7FT TH N SIFT TO TPB PROJECT LOCATION: 22009 76TH AVE W EDMONDS, WA 98026 PROJECT DESCRIPTION: SCOPE OF WORK ONLY PERTAINS TO THE TENANT IMPROVEMENT OF AN EXISTING BUILDING WHICH ONLY INCLUDES THE ADDITION OF TWO HIGH EFFICIENCY SPLIT SYSTEM HEAT PUMPS HVAC CONTRACTOR: EMERALD AIRE INC 5108 D STREET AUBURN, WA 98001 PROJECT MANAGER: CONTACT: EMERALD A I RE, INC, VOICE; (253) 872-5665 FAX: (253) 872-5797 INDEX: DRAIN PAN WHEN REQUIREC HEAT PUM DRAIN PAN WHEN REQUIRE[ f_l�.ii 711�i l woR-D/< :)s :)VO\DS T GENERAL MECHANICAL: STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSI, SMACNA, ASHRAE, MFPA, OTHER APPLICABLE AGENCIES AND AHJ AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY CODES: ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES AND ORDINANCES, IN CASE OF CONFLICT BETWEEN THE DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE MOST STRICT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY, THE MECHANICAL CONTRACTOR SHAL SATISFY CODE REQUIREMENTS & REQUIREMENTS OF THE CONTRACT DOCUMENTS AS A MINIMUM STANDARD, APPLICABLE CODES: 2018 WASHINGTON STATE BUILDING CODE 2018 WASHINGTON STATE MECHANICAL CODE 2018 WASHINGTON STATE ENERGY CODE GENERAL CONTRACTOR TO PROVIDE ACCESS TO FIRE AND/OR COMBINATION FIRE/SMOKE DAMPERS. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE PARTS LIST DESCRIPTION QTY PART NUMBER DRAIN PAN 1 DIV 6 2748E WALL BRACKET 1 SAU BS520 VIB. DAMPERS 1 SAU BVD40 PAN FITTINGS 1 DIV 6 1 MITSUBISHI WALL INSTALLATION DETAIL NTS VICINITY MAP: _ SFATTLE;HEIGHTS Swickard Toyota Edmonds-Woodway n High School p 212thstsw T 119Swedish Edmon`ds Campus WorldKids m International Preschool z12ahStsw Harbor Freight'Tocl_ A 99 Ranch Market — 9 Esperance J. �I r v 22. h's4w'' � r IQa 1 Ball ngef Park i/ j WhirlyBall Safeway it e Golf Course \` 23eth StSw ® �M i �y • \.1r Regal Cir.ebarre Scotts Bar & G{ill' M eke© A�Panera Brea NOT TO SCALE APPROVED PLANS MUST BE ON JOB SITE a Alake Terrace v ation Pavilion Mountlake Terrace WSEC & COMMISSIONING NOTES: THERMOSTATS SHALL BE INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND COOLING PER WSEC 403, 2. 4. 1, 1 ECONOMIZERS SHALL MODULATE OUTSIDE AIR FROM MINIMUM TO 100% ECONOMIZER CONTROLS SHALL BE CAPABLE OF EVALUATING OUTDOOR AIR COOLING CAPACITY PER WSEC C403. 3. 1, 1 INSULATE REFRIGERANT PIPING PER WSEC TABLE C403,2,8 SEAL DUCTWORK PER WSEC C403, 2, 7, 3 INSULATE DUCTWORK PER WSEC C403, 2, 7, 1 AND C403, 2, 7, 2 COMMISSIONING PER WSEC C408 INCLUDING COMMISSIONING PLAN, SYSTEMS Ter BALANCING, FUNCTIONAL TESTING, CONTROLS TESTING, OPERATION AND F' MAINTENANCE MANUALS, AND RECORD DRAWINGS, SHALL BE SUBMITTED TO OWNER ON PROJECT COMPLETION. INSTALL ALL THERMOSTATS AT 48' AFF REVISIONS DATE PAGES CHANGES REV1 REV2 REV3 REV4 REV5 City Of Edmonds Building Department Work MECHANICAL ---------------------------- Address 2209 76TH AVE W Owner WORLDKIDS Approved Date 05/30/2023 Building Official Erl fi C14*" 1 Permit Number BLD2023-0591 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Worldkids Edmonds Date 5/4/2023 Project Name Worldkids Edmonds Date 5/4/2023 System Name FC-1 Floor Area 290 System Name FC-2 Floor Area 496 ENGINEERING CHECKS SYSTEM LOAD ENGINEERING CHECKS SYSTEM LOAD Number of Systems COIL CFM Total Room Loads 361 Return Vented Lighting Return Air Ducts Return Fan Ventilation 10 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Number of Systems COIL CFM Total Room Loads 444 Return Vented Lighting Return Air Ducts Return Fan Ventilation 80 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Heating System Sensible Latent CFM Sensible Output per System 7,407 773 80 3,458 Output per System 9,102 1,323 75 3,232 Total Output (Btuh) o Total Output (Btuh) 0 Output (Btuh/sqft) 0 0 Output (Btuh/sgft) 0 0 Cooling System o 0 Cooling System 0 0 Output per System 77 -17 10 552 Output per System 902 21 80 4,414 Total Output (Btuh) 0 772 o Total Output (Btuh) 0 1,344 0 Total Output (Tons) 0 0 Total Output (Tons) 0 0 Total Output (Btuh/sqft) Total Output (Btuh/sqft) Total Output (sgft/Ton) 7,484 4,010 Total Output (sqft/Ton) 10,004 7,645 Air System Air System CFM per System HVAC EQUIPMENT SELECTION CFM per System HVAC EQUIPMENT SELECTION Airflow (cfm) Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sqft) Note: values above given at ARI conditions Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Jan 1 AM Airflow (cfm/sqft) Airflow (cfm/Ton) Outside Air (%) Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Outside Air (cfm/sgft) Note: values above given at ARI conditions Jun 6 PM Jan 1 AM Jun 2 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 19 °F Outside Air 10 cfm AL 70 IF 66 OF 110 OF I Heating Coil ----------------- 110 OF ROOM 70 OF 19 OF Outside Air 80 cfm AL 70 IF 54 OF Heating Coil Ell ROOM lliw 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) Air 10 cfm AL 74/63°F 74/63°F 55/54°F Cooling Coil 55 / 54 OF 53.7 % ROOM 74/63°F 84/66OF Outside Air 80 cfm 74/63°F 77/63°F 55/54°F -- _ JOutside Cooling Coil 55 / 54 OF 53.1 % ROOM 2 _ M 74/63°F EnergyPro 5.1 by EnergySoft User Number: 7487 RunCode: 2023-05-04T15:15:21 ID: Page 1 of 10 1 r EnergyPro 5.1 by EnergySoft User Number: 7487 Run Code: 2023-05-04T15:15:21 ID: Page 2 of 10 HVAC LEGEND & ABBREVIATIONS: N YSI E N ccFMI E GRD IDENTIFIER CFN n U SIDE WALL GRILL ® SUPPLY GRILLE ® THERMAFUSER ® RETURN AIR GRILLE 0 EXHAUST GRILLE 0 EXHAUST FAN HE!] EQUIPMENT TAG 0 T—STAT 0 CO/NO2 SENSOR 0cc OCCUPANCY SENSOR --� L/V WIRE DUCT RUN ELBOW I ED REDUCER SIDE TAPS 90 ELBOW W/ TURNING VANES /im\0` iuv0\ FLEXIBLE DUCT E=D MANUAL DAMPER 1`2 FD FIRE DAMPER EP sD SD SFD SMOKE DAMPER SFD SMOKE/FIRE DAMPER MOTORIZED DAMPER BDD a BACKDRAFT DAMPER M VARIABLE VOLUME/TEMPERATURE HP HEAT PUMP HP HORSEPOWER HTG HEATING HTR HEATER ID INSIDE DIAMETER IN INCHES KW KILOWATT LAT LEAVING AIR TEMPERATURE LBS. POUNDS LWT LEAVING WATER TEMPERATURE MA MIXED AIR MAX MAXIMUM MBH THOUSAND BTU'S PER HOUR MIN MINIMUM MS MOTOR STARTER NC NOISE CRITERIA NTS NOT TO SCALE OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OC ON CENTER OD OUTSIDE DIAMETER PH PHASE PSI POUNDS PER SQUARE INCH QTY QUANTITY R/A RETURN AIR REF REFRIGERANT RET RETURN RH RELATIVE HUMIDITY RLD RELIEF DAMPER RPM REVOLUTIONS PER MINUTE S/A SUPPLY AIR SEER SEASONAL ENERGY EFFICIENCY RATING SH SENSIBLE HEAT SOV SHUT OFF VALVE SP STATIC PRESSURE TEMP TEMPERATURE UC UNDERCUT DOOR V VOLT VAV VARIABLE AIR VOLUME VD VOLUME DAMPER (HAND OPERATOR) VEL VELOCITY W WATT W/ WITH WB WET BULB W/0 WITHOUT TTLE DPD STAMP RECEIVED May 24 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Y Df Q U z Ln x w LJ_ O z O w J a- O U O L� 0 W w Z O U V) W 0 V) Z 0 w Q 0 w PLOT DATE 5/4/2023 z W w m I— O Z U) a _ 0 z a 0 U) DESIGN DEVELOPMENT DRAWING DATE -- ❑ COORDINATION DATE ® PERMIT DATE CONSTRUCTION DATE ❑ AS BUILT DATE U) z O 3:N CD 00 Q0') L.J = < I— U) r- U7 0')Z — o o Q N C) w >O m w Z z � _J LLJ a -::j o:f U 0 HVAC COVER SHEET I SCALE: AS —NOTED M0.00 BLD2023-0591 5/4/2023 C:\Users\davisc\Desktop\General TI CAD Setup\ENGINEERING\CAD\KCFD20\Sheets\MO.00 HVAC COVER SHEET.dwg xxx-xxxx SUBMITTAL DATA: MSZ-GL09NA & MUZ-GL09NA MITSUBISHI 9,000 BTU/H WALL -MOUNTED HEAT PUMP SYSTEM At ELECTRIC Job Name: System Reference: Date: Indoor Unit: MSZ-GL09NA Outdoor Unit: ❑ MUZ-GL09NA-U1 ❑ MUZ-GL09NA-U2 ❑ MUZ-GL09NA-U8 ill!lIIIIIIIiiliiliiiilllll111�, E"`rR" Illllli II':Illlllllllilllllllllllll 'IIIIIIIIIIIIIIIIIIIiiiIIIIIIIIIDI ''Il Illllllr r Wireless Remote Controller GENERAL FEATURES • Slim wall -mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto • Multiple control options available: Hand-held Remote Controller (provided with unit) kumo cloud® smart device app for remote access Third -party interface options Wired or wireless controllers • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. Maximum Capacity BTU/H 12,200 Minimum Capacity BTU/H 3,600 Cooling Maximum Power Input W 1,050 Rated Power Input W 585 Moisture Removal Pints/h 1.5 Sensible Heat Factor 0.82 Power Factor % -U1/2: 86 / 86 -U8: 92 / 92 Maximum Capacity BTU/H -U1/2: 15,900 -U8: 14,100 Heating 47°F2 Minimum Capacity BTU/H 4,500 at Maximum Power Input W -U1/2: 1,250 -U8: 1,070 Rated Power Input W 720 Power Factor % -U1/2: 90 / 90 -U8: 95 / 95 Maximum Capacity BTU/H -U1/2: 10,900 -U8: 9,400 Heating 17°F3 Rated Capacity BTU/H -U1/2: 6,700 -U8: 7,000 at Maximum Power Input W -U1/2: 1,060 -U8: 790 Rated Power Input W 630 Heating 5°F4 Maximum Capacity BTU/H 8,170 at Maximum Power Input W 850 Heating at -4°F5 Maximum Capacity BTU/H 6,860 EER1 15.4 HSPF (IV) 12.8 Efficiency COP at 47°F2 4.44 COP at 17°F in Maximum Capacity3 2.82 COP at 5°F in Maximum Capacity4 2.82 ENERGY STAR® certified units (ENERGY STAR products are third -party certified by an EPA -recognized Certification Body.) YES Voltage, Phase, Frequency 208/23OV, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size (Outdoor) A 15 Recommended Wire Size (Indoor - Outdoor) AWG 14 MCA A 1 MOCP A 15 Indoor Unit Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170-145 © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. Job Name: System Reference: Date: Indoor Unit: MSZ-GL12NA Outdoor Unit: ❑ MUZ-GL12NA-U1 ❑ MUZ-GL12NA-U2 ��,ill!!f�riI�IIIIIIii�illlll111�, E`E`TR" Illllli il':I:Illllllllilllllllllllll I IIIIIIIIIIIIIIIIIIIiiiIIIIIIIIIDI '�IIIIIIIIIIIIIIIIIIDvh, Wireless Remote Controller I GENERAL FEATURES • Slim wall -mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto • Multiple control options available: Hand-held Remote Controller (provided with unit) kumo cloud® smart device app for remote access Third -party interface options Wired or wireless controllers • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. Airflow Rate at Cooling, Wet CFM 364-286-201-134-109 Airflow Rate at Heating, Dry CFM 406-321-237-170-145 Sound Pressure Level (Cooling) dB(A) 43-37-30-22-19 Sound Pressure Level (Heating) dB(A) 43-37-30-22-19 Drain Pipe Size In. (mm) 5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.OY 9.2/0.2 Unit Dimensions W: In. (mm) 31-7/16 (798) D: In. (mm) 9-1/8 (232) H: In. (mm) 11-5/8 (295) Package Dimensions W: In. (mm) 33-1/2 (850) D: In. (mm) 12 (300) H: In. (mm) 14 (350) Package Weight Lbs. (kg) 26 (11.5) Indoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum)* °F 90 DB, 73 WB / 67 DB, 57 WB Temperature Range Heating Intake Air Temp (Maximum / Minimum) °F 80 DB / 70 DB MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,229 / 1,172 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Coolingi dB(A) 48 Sound Pressure Level, Heating2 dB(A) 50 Compressor Type DC INVERTER -driven Outdoor Unit Compressor Model -U1: KNB073FRVMC -U2: KNB073FRXMC -U8: SNB092FQANT Compressor Rated Load Amps A 6.7 Compressor Locked Rotor Amps A 7.7 Compressor Oil Type // Charge oz. -U1/2: FV50S //9.1 -U8: FY50S //11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W: In. (mm) 31-1/2 (800) D: In. (mm) 11-1/4 (285) H: In. (mm) 21-5/8 (550) Package Dimensions W: In. (mm) 37 (940) D: In. (mm) 14-15/16 (380) © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. Maximum Capacity BTU/H 13,600 Minimum Capacity BTU/H 1,500 Cooling Maximum Power Input W 1,300 Rated Power Input W 920 Moisture Removal Pints/h 2.5 Sensible Heat Factor 0.77 Power Factor % 95/95 Maximum Capacity BTU/H 18,100 Heating 47°F2 Minimum Capacity BTU/H 2,000 at Maximum Power Input W 1,620 Rated Power Input W 1,100 Power Factor % 96 / 96 Maximum Capacity BTU/H 12,000 Heating 17°F3 Rated Capacity BTU/H 9,200 at Maximum Power Input W 1,240 Rated Power Input W 870 Heating 5°F4 Maximum Capacity BTU/H 9,790 at Maximum Power Input W 1,020 Heating at -4°F5 Maximum Capacity BTU/H 7,920 EER1 13.0 HSPF (IV) 12.5 Efficiency COP at 47°F2 3.84 COP at 17°F in Maximum Capacity3 2.84 COP at 5°F in Maximum Capacity4 2.81 ENERGY STAR® certified units (ENERGY STAR products are third -party certified by an EPA -recognized Certification Body.) YES Voltage, Phase, Frequency 208/23OV, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size (Outdoor) A 15 Recommended Wire Size (Indoor - Outdoor) AWG 14 MCA A 1 MOCP A 15 Indoor Unit Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170-145 © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. EQUIPMENT SCHEDULES NOTES: (APPLIES TO BOTH UNITS) H: In. (mm) 24-13/16 (630) U- Package Weight Lbs. (kg) 88 (40) Cooling Air Temp (Maximum / Minimum)* °F 115 / 14 Outdoor Unit Operating Cooling Thermal Lock -out / Re -start Temperatures- °F -1/3 Temperature Range Heating Air Temp (Maximum / Minimum) °F 75/4 Heating Thermal Lock -out / Re -start Temperatures- °F -9 / -4 Refrigerant Type R41OA Charge Lbs, oz -U1/2: 2, 5 -U8: 2, 9 Piping Maximum Piping Length Ft. (m) 65 (20) Maximum Height Difference Ft. (m) 40 (12) Maximum Number of Bends 10 Notes AHRI Rated Conditions lCooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed 2Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB compressor speed) 3Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB H 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB H -4 DB, -5 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. Airflow Rate at Cooling, Wet Airflow Rate at Heating, Dry CFM 364-286-201-134-109 CFM 406-321-237-170-145 Sound Pressure Level (Cooling) dB(A) 45-37-30-22-19 Sound Pressure Level (Heating) dB(A) 43-37-30-22-19 Drain Pipe Size In. (mm) 5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.OY 9.2/0.2 Unit Dimensions W: In. (mm) 31-7/16 (798) D: In. (mm) 9-1/8 (232) H: In. (mm) 11-5/8 (295) Package Dimensions W: In. (mm) 33-1/2 (850) D: In. (mm) 12 (300) H: In. (mm) 14 (350) Package Weight Lbs. (kg) 26 (11.5) Indoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum)* °F 90 DB, 73 WB / 67 DB, 57 WB Temperature Range Heating Intake Air Temp (Maximum / Minimum) °F 80 DB / 70 DB I Outdoor Unit MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,229 / 1,172 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Coolingi dB(A) 49 Sound Pressure Level, Heating2 dB(A) 51 Compressor Type DC INVERTER -driven Compressor Model SNB092FQAMT Compressor Rated Load Amps A 6.6 Compressor Locked Rotor Amps A 8.2 Compressor Oil Type // Charge oz. FV50S // 11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W: In. (mm) 31-1/3 (800) D: In. (mm) 11-1/5 (285) H: In. (mm) 21-5/9 (550) Package Dimensions W: In. (mm) 37 (940) D: In. (mm) 14-15/16 (380) H: In. (mm) 24-13/16 (630) © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Package Weight Lbs. (kg) 89 (40) Cooling Air Temp (Maximum / Minimum)* °F 115 / 14 Outdoor Unit Operating Cooling Thermal Lock -out / Re -start Temperatures- °F -1/3 Temperature Range Heating Air Temp (Maximum / Minimum) °F 75/4 Heating Thermal Lock -out / Re -start Temperatures- °F -9 / -4 Refrigerant Type R41OA Charge Lbs, oz 2,9 Piping Maximum Piping Length Ft. (m) 65 (20) Maximum Height Difference Ft. (m) 40 (12) Maximum Number of Bends 10 Notes AHRI Rated Conditions Cooling (Indoor // Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is 21-leating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB determined at a fixed compressor speed) 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB Conditions 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. 1. POWER FROM CORRESPONDING OUTDOOR UNIT TO BE WIRED BY EC AND MUST ONLY USE THE WIRE SIZE SHOWN IN THE HP INSTALLATION MANUAL 2. CONDENSATE PUMP PROVIDED BY EAI, ROUTE CONDENSATE TO EXTERIOR 3. MOUNT OUTDOOR UNITS TO WALL, PER PLAN, SEE DETAILS 4. NO ECONOMIZER REQUIRED PER WSEC C403.5, TABLE C403.5, EFFICIENCIES OF UNITS EXCEED REQUIRED MINIMUM LISTED IN TABLE C403.3.2(1)A-3, MINIMUM REQUIRED MUST BE 64% GREATER (21 SEER MINIMUM), UNITS ARE 23.1 OR GREATER. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. (n D- Y Of Q CD z X W LL_ O Z O J 0_ O U Of O LL_ 0 W >_W W Z O D_ W' U N W 0 V) Z zuz O >N L�1 W Q 0 PLOT DATE 5/4/2023 Z W SEATTLE DPD STAMP 13 F 0 m RECEIVED May 24 2023 CITY OF EDMONDS _ _ J DEVELOPMENT SERVICES 2' 8' LISTDEPARTMENT I �SIONAL ��Cs BLD2023-0591 Of 4t SCALE: 1 /8" = V-0" 16 �N PNOJ HT 5/ 4/ 2 0 2 3 C:\Users\davisc\Desktop\General TI CAD Setup\ENGINEERING\CAD\KCFD20\Sheets\MO.02 HVAC SCHEDULES.dwg s riN DESIGN DEVELOPMENT DRAWING DATE -- ❑ COORDINATION DATE ® PERMIT DATE 11 CONSTRUCTION DATE ❑ AS BUILT DATE U z O 3:N CD Q cy) LIJ = U) (9 � C) � Z - o o� Q N C) W O M � Z J LIJ Q J af U 0 rn J O� I r� �0 L00 Zp) L^CyQ I � Q N�roOO'w p Z � `'re) M W o,`0w� C-4i1�L. Q J LL. O O Q Q 0 w o a OL 0 U Q Nnnn N LJ W g HVAC SCHEDULES SCALE: AS -NOTED M0.01 XXX-XXXX 5/4/23, 3:56 PM https://waenergycodes.com/print project—summary_form. php?k=Y29tYm9fd GZ2X3BOPW 1 IY19odm FjX3N5cl 96b25pbmdfc2l uZ2xIJTd DcGRfYWxOZXJ hdGlvbiZOZnY9bWVjX2h2YW ... MECHANICAL COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2023 NEEA, All rights reserved Project &Applicant Information Project Title WORLDKIDS EDMONDS TI - 2018 WSEC For Building Department Use: )Date. May 04, 2023 Project Address WA Applicant Name Davis Cavanagh Applicant Phone 253-289-5102 Applicant Email davisc@emeraldaire.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type I Education, Preschool/Daycare Building Cond. Floor Area 1,104 General Project Types Alteration New Building or -Addition Mechanical Scope Alteration Mechanical Scope Single Zone Systems &Equipment Project Cond. Floor Area 1,104 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Mechanical Project Description SCOPE OF WORK ONLY PERTAINS TO THE TENANT IMPROVEMENT OF AN EXISTING BUILDING WHICH ONLY INCLUDES THE ADDITION OF TWO HIGH EFFICIENCY SPLIT SYSTEM HEAT PUMPS Project Economizer DOAS Ventilation Higher Equipment Equipment Efficiency Mechanical Compliance Type Mechanical Scope Exception(s) � Applied. Provided. ? Efficiency Option Applied. Compliance Verification Scope and Method Alteration Single Zone Systems & Yes No NA COMPLIES Equipment Additional Efficiency Credits Included (AEC) Does building include occupancy classifications requiring No Does project include DOAS equipment? No DOAS. Based on project scope do TSPR requirements apply? No Do all systems comply with Appendix D standard reference design or qualify for an exception to No TSPR? Scope & Space Conditioning ALTERATION - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES Single Zone Air Systems Category - Heat pump, unitary, thru-wall, SDHV Air Systems Summary Information System/Equip ID Quantity of Items Supply Airflow Control Ventilation Standard Ventilation CFM (Total if Multiple Items) Ventilation Air Source Paired with DOAS Ventilation energy recovery Energy Recovery Efficiency ('Y, ) FC-2 Constant volume IMC Natural Ventilation FC-I Constant volume IMC Natural Ventilation Air Systems & Equipment - Cooling System/ Equip ID Cooling System/Equip Type Specific Type Cooling Capacity per item (Btu/h) AEC Efficiency Multiplier Econo Exception Multiplier (FL & PL) Combined Efficiency Multiplier (AEC & Econo) Proposed Cooling Efficiency CE Units Proposed Part Load Efficiency PL Units Efficiency Compliance Verification FC-2 Heat pump, air cooled Split system 12,000 1 0 1 23.1 SEER IEER COMPLIES FC-1 Heat pump, air cooled Split system 9,000 1 0 1 24.6 SEER IEER COMPLIES Air Systems & Equipment - Heating System /Equip ID HeatingSystem/Equip T e Type S ecific Type P yp Heat Pump Heating Capacity Btu/h p g P y ( ) CoolingCapacity Btu/h p y ( ) AEC Efficiency Multiplier Proposed Heat Pump Heating Efficiency HPH Units Proposed Low OSA Temp Efficiency LTH Units Efficiency Compliance Verification FC-2 Heat pump, air cooled, heating Split system 14,400 12,000 1 12.5 HSPF COP COMPLIES FC-I Heat pump, air cooled, heating Split system 10,900 9,000 1 12.8 HSPF COP COMPLIES Air Systems & Equipment Details System/Equip ID I Area(s) Served Location In Project Documents - Plan/Detail # https://waenergycodes.com/print_ project_ su mmary_form. ph p?k=Y29tYm9fdGZ2X3BOPW 1 IY19od m FjX3N5cl 96b25pbmdfc2luZ2xlJTd DcG RfYWxOZXJhdGlvbiZOZnY9bWVjX2h2YW Nfc3lzX3pvbml uZ1 ... 1 /2 5/4/23, 3:56 PM https://waenergycodes.com/print_ project _summary_form.php?k=Y29tYm9fdGZ2X3BOPW11Y1god mFjX3N5cl96b25pbmdfc2luZ2xlJTdDcGRfYWxOZXJhdGlvbiZOZnY9bWVjX2h2YW... FC-2 BACK ROOM I M2.01 System/Equip ID for a single or multiple items?: Single item Heating Section/Auxiliary Heating Type: Other source Economizer Compliance Method: Economizer not required WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(2) - Unitary and Applied Heat Pumps Proposed Low OSA Temp Efficiency: LTH Units: COP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(2) - Unitary and Applied Heat Pumps FC-1 FRONT ROOM I M2.01 System/Equip ID for a single or multiple items?: Single item Heating Section/Auxiliary Heating Type: Other source Economizer Compliance Method: Economizer not required WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(2) - Unitary and Applied Heat Pumps Proposed Low OSA Temp Efficiency: LTH Units: COP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(2) - Unitary and Applied Heat Pumps PROVIDE UNITS WITH CONDENSATE PUMPS, CONDENSATE ROUTED TO EXTERIOR 0 FG1 ---\ N� 00 R� 00 � \q 9�s �o �m �y 12 WALL MOUNT UNITS, STACK VERTICALLY, BOTTOM OF UNITS @ 4' AFF PROVIDE UNITS WITH FC-2 CONDENSATE PUMPS, CONDENSATE ROUTED TO EXTERIOR WALLMOUNTED FANCOIL LOCATED ON WALL, ROUTE REFER PIPE THRU ATTIC, MOUNT UNIT HIGH, TOP OF UNIT NO CLOSER THAN 411 TO CEILING, VERIFY WITH OWNER HP-1 ---------- \ :11 ROUTE REFER PIPING UP AND INTO ATTIC, USE LINEHIDE ON EXTERIOR N fl `1 Q C.� Z D X W LL- O Z _O J IL M O U IY O LL- 0 w >_w W Z O_ F— a_ IY U V) W V) Z O W W' W Q 0 IY Z PLOT DATE 5/4/2023 W SEATTLE DPD STAMP RECEIVED May 24 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ❑ DESIGN DEVELOPMENT DRAWING DATE -- ❑ COORDINATION DATE ® PERMIT DATE ❑ CONSTRUCTION DATE ❑ AS BUILT DATE 0 z 0 3;:N w00 0 Q (J) LLJ = < I— U� V) o Cn —o o� 0 CA w J 0 m w z � LIJ J Q rn arm r 3mzI�oLO N (DLn0 �� Q I�^Q � OZ� tryLd �, W 00 o�LOw� C14 I.L. Q J L,OU F- Q Q � y i IWJ F- LL1 l O o a Of 1- Q) o U C p� N IJ w g H VAC PLAN SCALE: 1/4" = 1'-0" 21 8' DBLD2023-0591 0' 41 SCALE: 1 /8" = 1'-0" 16' PNOJ CT 5/4/2023 C:\Users\davisc\Desktop\General TI CAD Setup\ENGINEERING\CAD\KCFD20\Sheets\M2.01 HVAC PLAN.dwg