BLD2023-1360_Other_10.27.2023_11.30.07_AM_3865938PV Single Line - - - - - - - - - - - - - - - - String 1 — +� z 13 modules PI o V String 2 U 10 modules String 3 8 modules 0 Equipment Schedule A Storage Single Line I 0 ------ I I I I I I I A A 60A/2p I I • I I I I 30A/2p I I 2 L-- 30A/2p Battery Disconnect, Located within 10' of net meter PV breaker in Gateway to serve as exterior solar rapid shutdown initiation device 200A TESLA Gateway2 with 200A Internal Panelboard Solar OCPD:60A Battery OCPD:60A Co -Located with Net Meter Battery combiner panel I I I Bus Rating: 125A I o ' I I I 4/0 XHHW-2 ( I L1 & L2) ----------------------------—-=--———————————————------------------------- 2/ 0 XHHW-2 Ref. Category Equipment QTY 1 Modules Q.Peak DUO BLK ML-G10+ 405 31 2 Optimizers S440 SolarEdge Optimizer 31 3 Jbox Soladeck 5 41 Inverters I Solar Edge SE10000H 1 Monitoring I SolarEdge PV Inverter Monitoring 1 0 Conductor Schedule I nverter Specs Watts LW-1 Output AC Voltage # of Inverters OCPD u Solar Edge SE11400H 11400 47.5 240 1 60 ****N/A**** 0 0 0 0 0 ****N/A**** 0 0 0 0 0 Module Specs Watts w LrKLp Vmp Voc Isc Q.Peak DUO BLK VIL-G10+4 405 10.83 37.39 45.34 11.17 Temp. Adjusted 0 0 32.8 1 49.3 0 Summary Distance (ft) Current @125% Operating Voltage Voltage Drop V. Drop (total) A (2)#10 CU, (1)#6 EGC, PV Wire 600V, AIR 50 18.75A 400V 0.41% 0.99% B (6)#10 CU, (1)#10 EGC, THWN-2, 0.75"EMT(min) 50 18.75A 400V 0.41% C (2)#6 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) 10 52.5A 240V 0.17% (N) #6 THWN-2 200A/2p (EGC) Protected Loads Panel (Existing) Main Service Panel (lph 240V Service) Main Breaker: 200A Bus Rating:200A 0 Equipment Schedule Ref. Category Equipment QTY 1 Gateway Tesla Backup Gateway2: Service Rated 1 Breakers 200A Main Breaker (Eaton CSR2200N) 1 Misc. Tesla 200A Internal Panelboard Kit 1 Breakers 2p60A, 2p60A 2 Battery Tesla Powerwall 2, 13.5 kWh 2 Misc. Powerwall Stack Kit 1 3 Loadcenters MLO, 125A, 240V, 1ph, Nema 1, Flush, 8 space (min.) 1 Breakers 2p60A, 2p30A, 2p30A Misc. Breaker Hold down kit 1 4 Disconnect 60A 600V 2 Pole I Heavy Duty, No Fuse, Lockable 1 Misc. Neurio Meter Kit 1 0 Conductor Schedule ■=A&RScope `,'I' I = Existing or A&RSOLAR Others Scope 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 OI Net Meter 4/0 XHHW-2 (L1 & L2) 2/0 XHHW-2 (N) 200A/2p Unprotected Loads Panel (Existing) Main Service Panel (lph 240V Service) Main Breaker: 200A Bus Rating:200A Inverter Specs Watts Output AC Voltage # of Inverters OCPD LW-1 Tesla Powerwall 2 5000 1 24 240 2 30 Summary Distance (ft) Current @125% Operating Voltage Voltage Drop A (4)#10 CU, (2)#10 N, (1)#10 EGC, THWN-2, & com wire, 1"EMT(min) 10 30A 240V 0.25% B (2)#6 CU, (1)#6 N, (1)#10 EGC, THWN-2, & com wire, 1"EMT(min) 10 60A 240V 0.20% THIS DRAWING CONSTITUTES THE :ONFFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR POSSESSION DOES NOT :ONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATTION DISCLOSED HERE IN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HERE IN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. L O 07 p� O C: O N a-+ O CO 00)Lnm ■ Q Q I O 00 N Q Q 4W U O o (f) a-+ O N Ln �10 U O �� U w a� Ln Ln Ln N REVISIONS Rev. #: Date: 1 1 Oct 23, 2023 General Notes: Designed by: Thomas N Utility: Snohomish PUD PM: Will MacArthur 1. EGC Where exposed to physical damage will be #6AWG (206) 307-1741 Bare CU Current Date:Oct 23, 2023 2. If installing conduit on the roof, maintain greater than 7/8" above the surface 3. NEC 690.12: Rapid Shutdown initiated by AC Disconnect I E1 Single Line