Loading...
BLD2023-1375_Manufacturer_Specifications_and_Installation_Instructions_10.30.2023_2.15.01_PM_3869531c)z=C)M °0 0 00 CC) �2) CC) CcD Q°C/)mmN a:N CD CD =, n5 z, n. Cn CD CD .. CD �jjo�� Cn �� o �o L cn o m m � c� N � � C o- 0 � u m CTI 7- co C I ii1111111111111111111\\\\\\\\\\\\\\\\\\\ ll�llli1111111111111111����\\��\����\��\ i 6 L L L yU1.164. � -0n r. a� 3y Q CD 0 3 0 Y Table of Contents RP14AZ Table of Contents Features & Benefits..................................................................3 Model Number Identification....................................................4 General Data/Electrical Data....................................................5 Accessories..............................................................................6 Weighted Sound Power.......................................................... 6 UnitDimensions.......................................................................7 Clearances...............................................................................8 ControlWiring..........................................................................9 Refrigerant Line Size Information ..................................... 10-11 Performance Data..................................................................12 Limited Warranty....................................................................16 2 Features and Benefits RP14AZ Features and Benefits • Swept Wing Fan Technology': Features quieter operation and improved unit acoustics • Two -Stage Scroll Compressor2: Features two speeds (high and low) of cooling and heating, providing more precise temperature control, lower humidity and greater efficiency when compared to single stage compressors • Inverted Reversing Valve: Allows for faster heat transfer with gravity assist shifting and reduced joint stress for increased reliability 'Does not apply to the 3.5 and 4 Ton 2Does not apply to the 1.5 Ton 1-stage model • PlusOne® Expanded Valve Space: 3 in. - 4 in. - 5 in. service valve space —provides a minimum working area of 27-square inches for easier access • PlusOne® Triple Service Access: 15 in. wide, industry leading corner service access, two fastener, removeable corner and individual louver panels —makes repairs easier and faster Model Number Identification RP14AZ R P 14 A z 18 A J 1 N A Brand Product SEER2 Region Refrigerant Capacity Major Series Voltage Type Controls Minor Category Series R - Rheem P - Heat Pump 14 -14.3 SEER2 A - All Regions Z - R-410A 18-18,000 [5.28 kW] A -1 st Design J - 208/230/1/60 1 -1-Stage N - Non -Comm. A -1 st Design 24 - 24,000 [7.03 kW] 2 - 2-Stage 30 - 30,000 [8.79 kW] 36 - 36,000 [10.55 kW] 42 - 42,000 [12.31 kW] 48 - 48,000 [14.07 kW] 60 - 60,000 [17.58 kW] [ ] Designates Metric Conversions AVAILABLE MODELS DESCRIPTION RP14AZ18AJl NA EndeavorTM Line Classic® Series 1 1/2 ton 14.3 SEER2 1-Stage iM Heat Pump-208/230/1/60 RP14AZ18AJ2NA EndeavorTM Line Classic® Series 1 1/2 ton 14.3 SEER2 2-Stage iM Heat Pump-208/230/l/60 RP14AZ24AJ2NA EndeavorTM Line Classic® Series 2 ton 14.3 SEER2 2-Stage Heat iM Pump-208/230/1/60 RP14AZ30AJ2NA EndeavorTM Line Classic® Series 21/2 ton 14.3 SEER2 2-Stage iM Heat Pump-208/230/1/60 RP14AZ36AJ2NA EndeavorTM Line Classic® Series 3 ton 14.3 SEER2 2-Stage iM Heat Pump-208/230/1/60 RP14AZ42AJ2NA EndeavorTM Line Classic® Series 3 1/2 ton 14.3 SEER2 2-Stage iM Heat Pump-208/230/1/60 RP14AZ48AJ2NA EndeavorTM Line Classic® Series 4 ton 14.3 SEER2 2-Stage iM Heat Pump-208/230/1/60 RP14AZ60AJ2NA EndeavorTM Line Classic® Series 5 ton 14.3 SEER2 2-Stage iM Heat Pump-208/230/1/60 STANDARD EQUIPMENT R-410A Refrigerant Scroll Compressor Field Installed Filter Drier Front Seating Service Valves Internal Pressure Relief Valve Internal Thermal Overload Long Line capability Low Ambient capability with Kit 3-4-5 Expanded Valve Space Composite Basepan 2 Screw Control Box Access 15" Access to Internal Components Quick release louver panel design No fasteners to remove along bottom Optimized Venturi Airflow Single row condenser coil Powder coated paint Rust resistant screws OR code External gauge ports Service trays External gauge ports Service trays 4 General Data/Electrical Data RP14AZ General Data GENERAL DATA MODEL NO. RP14AZ18-1 13P14AZ18-2 RP14AZ24 I RP14AZ30 I RP14AZ36 I RP14AZ42 I RP14AZ48 I RP14AZ60 Nominal Tonnage 1.5 1.5 2.0 2.5 3.0 3.5 4.0 5.0 Valve Connections Liquid Line O.D. - in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line O.D. - in. 3/4 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant (R410A) furnished oz.' 84 88 88 108 118 148 1 148 247 Compressor Type Scroll Outdoor Coil Net face area - Outer Coil 10.9 10.9 10.9 1 14.4 1 19.5 19.5 19.5 28.4 Net face area - Inner Coil Tube diameter - in. 0.276 0.276 0.276 0.276 0.276 0.276 0.276 0.375 Number of rows 1 1 1 1 1 1 1 1 Fins per inch 22 22 22 22 22 22 24 20 Outdoor Fan Diameter - in. 20 20 20 24 24 24 24 26 Number of blades 3 3 3 3 3 3 3 3 Motor hp 1/7 1/7 1/6 1/5 1/5 1/5 1/5 1/5 CFM 2401 2401 2620 3391 4077 4077 4096 4686 RPM 1075 1075 1075 850 850 850 850 850 Watts 146 141 145 175 234 222 236 239 Shipping weight - lbs. 157 157 158 196 209 239 245 285 Operating weight - lbs. 150 150 151 189 202 232 238 278 Electrical Data Line Voltage Data (Volts -Phase -Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection (amps)2 20 15 20 25 25 35 35 40 Minimum circuit ampacity3 11 11 15 18 21 26 29 31 Compressor Rated load amps 10 1 8 1 11 1 13 1 15 1 20 1 22 1 24 Locked rotor amps 46 1 56 66 71 78 151 0 118 Condenser Fan Motor Full load amps 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 Locked rotor amps 1.4 1.4 1.5 2.6 2.56 2.56 2.56 2.6 'Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 3Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. Accessories/Weighted Sound Power RP14AZ Accessories MODEL NO. RP14AZ18**1 RP14AZ18**2 RP14AZ24 RP14AZ30 RP14AZ36 RP14AZ42 RP14AZ48 RP14AZ60 Compressor crankcase heater* 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 Factory Standard Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-Al SK-Al SK-Al SK-Al SK-Al SK-Al SK-Al SK-Al Low pressure control Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard High pressure control Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (24 VAC, 50/60 Hz) Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid VAC, Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (120/240 50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V Classic Top Cap w/Label 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 *Bi-flow kits are required when installing a liquid line solenoid on a heat pump. Weighted Sound Power Level (dBA) UNIT SIZE - VOLTAGE, SERIES STANDARD RATING(DBA) TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment) 125 250 500 1000 2000 4000 8000 RP14AZ18A 73 39.8 55 62.1 67.0 60.0 57.4 51.2 RP14AZ24A 73 40.4 55.4 62.5 65.9 58.7 56.4 48.9 RP14AZ30A 72 48.9 55.3 63.6 61.0 59.1 56.5 48.7 RP14AZ36A 72 50.1 55.8 64.4 61.5 58.7 55.1 50.9 RP14AZ42A 72 48.6 56.2 63.1 61.7 60.0 56 50.0 RP14AZ48A 74 49.3 56 64.5 64.5 60.1 54.9 47.7 RP14AZ60A 74 43.9 55.2 63.4 65.8 61.7 57.9 52.9 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI) Unit Dimensions RP14AZ Unit Dimensions MODEL NO. OPERATING SHIPPING H (Height) L (Length) W (Width) H (Height) L (Length) W (Width) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RP14AZ18"1 25.00 635 29.75 756 29.75 756 27.90 709 33.25 845 33.25 845 RP14AZ18"2 25.00 635 29.75 756 29.75 756 27.90 709 33.25 845 33.25 845 RP14AZ24 25.00 635 29.75 756 29.75 756 27.90 709 33.25 845 33.25 845 RP14AZ30 27.00 686 33.75 857 33.75 857 30.08 764 37.64 956 37.64 956 RP14AZ36 35.00 889 33.75 857 33.75 857 38.35 974 37.64 956 37.64 956 RP14AZ42 35.00 889 33.75 857 33.75 857 38.35 974 37.64 956 37.64 956 RP14AZ48 35.00 889 33.75 857 33.75 857 38.35 974 37.64 956 37.64 956 RP14AZ60 45.00 1143 35.75 908 35.75 908 48.50 1232 39.37 1000 39.37 1000 ALLOW 60" [1524 mm] OF CLEARANCE SERVICE PANELS/ INLET CONNECTIONS / HIGH & LOW VOLTAGE ACCESS ALLOW 24" [610 mm] OF CLEARANCE 'L AIR INLET LOUVERS ALLOW 6" [152 mm] MIN. OF CLEARANCE ALL SIDES 12" [305 mm] RECOMMENDED [ ] Designates Metric Conversions ST-A1226-02-00 0 1 v CLEARANCES N v WALL 6" (152.4) 24" 12" 609.E (304.8) Service 6" (152.4) 24" (609.6) Service 18" 24" (457.2) (609.6) 24" recommended 6" minimum 12" (304.8) WALL 24" 24" (609.6) (609.6) Service Service 24" (609.6) 24" recommended 6" minimum NOTE: NUMBERS IN () = mm IMPORTANT., When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re -circulation of discharge air. ST-A1225-01-00 Control Wiring/Application Guidelines RP14AZ Control Wiring FIGURE 4 CONTROL WIRING FOR AIR HANDLER WIRING INFORMATION Line Voltage T-Field Installed— — — — Fa,to,Y standa,d — Heat Pump Thermostat TYPICAL THERMOSTAT: NOTES: Q Q O O Q Q HEAT PUMP WITH ELECTRIC HEAT 1. Jumper "E" to "W2" to transfer control of supplemental heat to 1st stage when the t t emergency heat switch 9 Y ` is on. Heat Pump 2. This wire turns on heat ` Outdoor Unit for defrost, omit for most r rr ' economical operation. Y r r 3. Wire with colored tracing - + -- ' ---------- B stripe. p r ' ------ C r ' r r r ---- ' r r , , D ' ; ' r , NOTE: RED WIRE REQUIRED WITH RANCID DDL DEMAND DEFROST CONTROL. Application Guidelines 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operation air temperature for cooling mode without low -ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature is 125°F (51.7°C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 6. Do not apply capillary tube indoor coils to these units. 7. Factory -supplied filter drier must be installed. Refrigerant Line Size Information RP14AZ Refrigerant Line Size Information 14.3 SEER2 HEAT PUMPS UNIT SIZE ALLOWABLE LIQUID LINE SIZE ALLOWABLE SUCTION LINE SIZE EQUIVALENT LENGTH (FEET) < 15 16-25 26-50 1 51-75 76-100 101-125 126-150 MAXIMUM VERTICAL RISE (OUTDOOR UNIT BELOW INDOOR UNIT) * / CAPACITY MULTIPLIERER 1/4" 5/8" 15 / 1.00 25 / 1.00 50 / 0.99 60 / 0.97 45 / 0.96 10 / 0.95 N/A 1.5 Ton Single Stage 5/16" 5/8" 15 / 1.00 25 / 1.00 50 / 0.99 75 / 0.97 90 / 0.96 45 / 0.95 N/A 3/8" 5/8" 15 / 1.00 25 / 1.00 50 / 0.99 75 / 0.97 95 / 0.96 80 / 0.95 N/A 1/4" 1/2" 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 50 / 0.95 N/A N/A 5/16" 1/2" 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 50 / 0.95 N/A N/A 1.5 Ton 3/8" 1/2" 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 50 / 0.95 N/A N/A Two Stage 1/4" 5/8" 15 / 0.99 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.96 50 / 0.95 50 / 0.94 5/16" 5/8" 15 / 0.99 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.96 50 / 0.95 50 / 0.94 3/8" 5/8" 15 / 0.99 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.96 50 / 0.95 50 / 0.94 1/4" 5/8" 15 / 0.99 25 / 0.99 50 / 0.99 31 / 0.97 3 / 0.97 N/A N/A 2 Ton Two Stage 5/16" 5/8" 15 / 0.99 25 / 0.99 50 / 0.99 50 / 0.97 50 / 0.97 50 / 0.96 50 / 0.95 3/8" 5/8" 15 / 0.99 25 / 0.99 50 / 0.99 50 / 0.97 50 / 0.97 50 / 0.96 50 / 0.95 1/4" 5/8" 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 46 / 0.95 50 / 0.94 N/A 5/16" 5/8" 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 50 / 0.95 50 / 0.94 N/A 2.5 Ton 3/8" 5/8" 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 50 / 0.95 50 / 0.94 N/A Two Stage 1/4" 3/4" 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.96 50 / 0.95 5/16" 3/4" 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.96 50 / 0.95 3/8" 3/4" 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.96 50 / 0.95 5/16" 5/8" 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.95 50 / 0.93 50 / 0.91 N/A 3/8" 5/8" 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.95 50 / 0.93 50 / 0.91 N/A 3 Ton Two Stage 5/16" 3/4" 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.97 50 / 0.96 3/8" 3/4" 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.97 50 / 0.96 1/2" 3/4" 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.97 50 / 0.96 3/8" 3/4" 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.97 50 / 0.96 50 / 0.96 3.5 Ton 1/2" 3/4" 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.97 50 / 0.96 50 / 0.96 Two Stage 3/8" 7/8" 15 / 1.00 25 / 0.99 15 / 1.00 50 / 0.98 50 / 0.98 50 / 0.97 50 / 0.97 1/2" 7/8" 15 / 1.00 25 / 0.99 15 / 1.00 50 / 0.98 50 / 0.98 50 / 0.97 50 / 0.97 3/8" 3/4" 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.95 50 / 0.94 50 / 0.93 4 Ton 1/2" 3/4" 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.95 50 / 0.94 50 / 0.93 Two Stage 3/8" 7/8" 15 / 1.00 25 / 0.99 50 / 1.00 50 / 0.97 50 / 0.98 50 / 0.98 50 / 0.97 1/2" 7/8" 15 / 1.00 25 / 0.99 50 / 1.00 50 / 0.97 50 / 0.98 50 / 0.98 50 / 0.97 3/8" 3/4" 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.95 50 / 0.93 50 / 0.91 N/A 5 Ton 1/2" 3/4" 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.95 50 / 0.93 50 / 0.91 N/A Two Stage 3/8" 7/8" 15 / 1.00 25 / 0.99 40 / 0.99 15 / 0.99 50 / 0.98 50 / 0.97 50 / 0.96 1/2" 7/8" 15 / 1.00 25 / 0.99 1 50 / 1.00 1 50 / 0.99 50 / 0.98 50 / 0.97 50 / 0.96 NOTES: 1) Do not exceed 200 ft linear line length. 2) 'Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit. 3) Always use the smallest liquid line allowable to minimize refrigerant charge. 4) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 5) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. 10 Refrigerant Line Size Information RP14AZ Refrigerant Line Size Information (Con't.) 14.3 SEER2 HEAT PUMPS UNIT SIZE ALLOWABLE LIQUID LINE SIZE MM [IN.] ALLOWABLE SUCTION LINE SIZE MM [IN.] EQUIVALENT LENGTH (METERS) 0-4.5 5-7.5 8-15 15.5-23 23.5-30 30.5-38 38.5-46 MAXIMUM VERTICAL RISE (OUTDOOR UNIT BELOW INDOOR UNIT) " / CAPACITY MULTIPLIER 5.3 KW 6.35 [1/4] 15.88 [5/8] 15 / 1.00 25 / 1.00 50 / 0.99 60 / 0.97 45 / 0.96 10 / 0.95 N/A [1.5 Ton] 7.94 [5/16] 15.88 [5/8] 15 / 1.00 25 / 1.00 50 / 0.99 75 / 0.97 90 / 0.96 45 / 0.95 N/A Single Stage 9.53 [3/8) 15.88 [5/8] 15 / 1.00 25 / 1.00 50 / 0.99 75 / 0.97 95 / 0.96 80 / 0.95 N/A 6.35 [1/4] 12.7 [1/2] 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 50 / 0.95 N/A N/A 7.94 [5/16] 12.7 [1/2] 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 50 / 0.95 N/A N/A 5.3 KW Ton] 9.53 [3/8] 12.7 [1/2] 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 50 / 0.95 N/A N/A [1.5 Two Stage 6.35 [1/4] 15.88 [5/8] 15 / 0.99 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.96 50 / 0.95 50 / 0.94 7.94 [5/16] 15.88 [5/8] 15 / 0.99 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.96 50 / 0.95 50 / 0.94 9.53 [3/8] 15.88 [5/8] 15 / 0.99 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.96 50 / 0.95 50 / 0.94 7.0 KW 6.35 [1/4] 15.88 [5/8] 15 / 0.99 25 / 0.99 50 / 0.99 31 / 0.97 3 / 0.97 N/A N/A [2 Ton] 7.94 [5/16] 15.88 [5/8] 15 / 0.99 25 / 0.99 50 / 0.99 50 / 0.97 50 / 0.97 50 / 0.96 50 / 0.95 Two Stage 9.53 [3/8] 15.88 [5/8] 15 / 0.99 25 / 0.99 50 / 0.99 50 / 0.97 50 / 0.97 50 / 0.96 50 / 0.95 6.35 [1/4] 15.88 [5/8] 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 46 / 0.95 50 / 0.94 N/A 7.94 [5/16] 15.88 [5/8] 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 50 / 0.95 50 / 0.94 N/A 8.8 KW 9.53 [3/8] 15.88 [5/8] 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.96 50 / 0.95 50 / 0.94 N/A [2.5 Ton] Two Stage 6.35 [1/4] 19.05 [3/4] 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.96 50 / 0.95 7.94 [5/16] 19.05 [3/4] 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.96 50 / 0.95 9.53 [3/8) 19.05 [3/4] 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.96 50 / 0.95 7.94 [5/16] 15.88 [5/8] 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.95 50 / 0.93 50 / 0.91 N/A 10.6 KW 9.53 [3/8] 15.88 [5/8] 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.95 50 / 0.93 50 / 0.91 N/A [3 Ton] 7.94 [5/16] 19.05 [3/4] 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.97 50 / 0.96 Two Stage 9.53 [3/8] 19.05 [3/4] 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.97 50 / 0.96 12.7 [1/2] 19.05 [3/4] 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.98 50 / 0.98 50 / 0.97 50 / 0.96 9.53 [3/8] 19.05 [3/4] 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.97 50 / 0.96 50 / 0.96 12.3 KW 12.7 [1/2] 19.05 [3/4] 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.97 50 / 0.96 50 / 0.96 [3.5 Ton] Two Stage 9.53 [3/8] 22.23 [7/8] 15 / 1.00 25 / 0.99 15 / 1.00 50 / 0.98 50 / 0.98 50 / 0.97 50 / 0.97 12.7 [1/2] 22.23 [7/8] 15 / 1.00 25 / 0.99 15 / 1.00 50 / 0.98 50 / 0.98 50 / 0.97 50 / 0.97 9.53 [3/8] 19.05 [3/4] 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.95 50 / 0.94 50 / 0.93 14.1 KW Ton] 12.7 [1/2] 19.05 [3/4] 15 / 1.00 25 / 0.99 50 / 0.98 50 / 0.97 50 / 0.95 50 / 0.94 50 / 0.93 [4 Two Stage 9.53 [3/8] 22.23 [7/8] 15 / 1.00 25 / 0.99 50 / 1.00 50 / 0.97 50 / 0.98 50 / 0.98 50 / 0.97 12.7 [1/2] 22.23 [7/8] 15 / 1.00 25 / 0.99 50 / 1.00 50 / 0.97 50 / 0.98 50 / 0.98 5JN/A 9.53 [3/8] 19.05 [3/4] 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.95 50 / 0.93 50 / 0.91 17.6 KW Ton]9.53 12.7 [1/2] 19.05 [3/4] 15 / 0.99 25 / 0.99 50 / 0.97 50 / 0.95 50 / 0.93 50 / 0.91 [5 Stage12.7 [3/8] 22.23 [7/8] 15/1.00 25/0.99 40/0.99 15/0.99 50/0.98 50/0.97 5Two [1/2] 22.23 [7/8] 15/1.00 25/0.99 50/1.00 50/0.99 50/0.98 50/0.97 5 NOTES: 1) Do not exceed 200 ft linear line length. 2) *Do not exceed 100 it vertical separation if outdoor unit is above indoor unit. 3) Always use the smallest liquid line allowable to minimize refrigerant charge. 4) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 5) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. is Performance Data RP14AZ Performance Data @ AHRI Standard Conditions -Cooling DESIGNATED TESTED COMBINATION (DTC) OUTDOOR UNIT AIR HANDLER TOTAL CAPACITY BTU/H [kW] NET SENSIBLE BTU/H [kW] NET LATENT BTU/H [kW] SEER2 EER2 INDOOR CFM [L/S] 47 DEGREE HEATING CAPACITY BTU/H [KW] 47 DEGREE COP 17 DEGREE HEATING CAPACITY BTU/H [KW] 17 DEGREE COP REGION IV HSPF2 RP14AZ18AJ1 RH2TZ2417STANN 17,100 [5.0] 13,100 [3.8] 4,000 [1.2] 14.3 9.0 575 [271.41 17,100 [5.0] 3.78 11,100 [3.3] 2.56 7.5 RP14AZ18AJ21 RH2TZ2417STANN 17,100 [5.0] 13,100 [3.8] 4,000 [1.2] 14.3 1 9.0 550 [259.6] 17,100 [5.0] 3.58 11,000 [3.2] 2.52 7.5 RP14AZ24AJ2 RH2TZ2417STANN 22,800 [6.7] 17,500 [5.1] 5,300 [1.6] 14.3 9.0 775 [365.81 22,800 [6.7] 3.51 14,600 [4.3] 2.55 7.5 RP14AZ30AJ2 RH2TZ3617STANN 28,600 [8.4] 21,900 [6.4] 6,700 [2.0] 14.3 9.0 950 [448.41 28,600 [8.4] 3.56 18,200 [5.3] 2.57 7.5 RP14AZ36AJ2 RH2TZ3617STANN 34,200 [10.0] 26,200 [7.7] 8,000 [2.3] 14.3 9.0 1,050 [495.5] 34,200 [10.0] 3.27 23,600 [6.9] 2.49 7.5 RP14AZ42AJ2 RH2TZ4821 STAN N 39,500 [11.6] 30,300 [8.9] 9,200 [2.7] 14.3 9.0 1,275 [601.7] 39,500 [11.6] 3.69 25,500 [7.5] 2.67 7.5 RP14AZ48AJ2 RH2TZ4821 STAN N 45,500 [13.3] 34,900 [10.2] 10,600 [3.1] 14.3 9.0 1,450 [684.31 45,500 [13.0] 3.65 27,500 [8.1] 2.54 7.5 RP14AZ60AJ2 RH2TZ6024STANN 55,500 [16.3] 42,600 [12.5] 12,900 [3.8] 14.3 9.0 1,800 [849.5] 55,500 [16.3] 2.66 34,000 [10.0] 2.56 7.5 NOTE: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match -ups, along with downloadable certificates, will be accessible from the AHRI website: www.ahridirectory.org later this year. [ ] Designates Metric Conversions 12 Notes RP14AZ 13 Notes RP14AZ 14 Notes RP14AZ 15 1 e o The new degree of comfort' GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts which fails in normal use and service within the applicable (Registration Required).................................Ten (10) Years period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. © 2023 Rheem Manufacturing Company. Rheem trademarks owned by Rheem Manufacturing Company. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating • 5600 Old Greenwood Road Rheem Canada Ltd./Ltee • 125 Edgeware Road, Unit 1 Fort Smith, Arkansas 72908 • www.rheem.com Brampton, Ontario • L6Y OP5 • rheem.ca PRINTED IN U.S.A. 4/23 QG FORM NO. P11-828 REV. 2